HomeMy WebLinkAbout17020_Chronicle Mill_SIR_20220706 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 07/08/2022 12:23 PM I. Inspection Information Date & Time: 07/06/2022 11:21 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Camden DeVane, Aaron Long - Excell Engineering Location: Lat: 35.242757, Long: -81.0334367, Brownfields Inspection Report: Chronicle Mill, 17020-13-036 07/06/2022 11:21 AM Page 2 of 6 II. Project Information Number: 17020-13-036 Name: Chronicle Mill Address: 96 East Catawba Street City: Belmont County: Gaston III. Environmental Current Use of Property: Residential Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: VIMS barrier is in the tenant space adjacent to sub-grade pedestrian walkway has been partially installed, however. By walking on areas where concrete had been washed out of mixer or truck. It was aparent that it had not been removed (Photos 1-3). See Inspector Comments section. Summary: N/A Summary: New construction, and renovated textile mill building currently under construction. Both buildings will be utilized as high-density residential apartment buildings. Summary: Consistant with property redevelopment, and EMP. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 07/06/2022 11:21 AM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Observed Chemical Violation: Unknown Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: Open can of acetone observed in a portion of the building and paint products (Photos 4). See Inspector Comments. Condition: Summary: N/A No risk to the public was observed at the time of the Site Inspection. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 07/06/2022 11:21 AM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: VIMS barrier spread out, and taping begun within future tenant space. Site inspection was performed to observe sub-slab soil gas sampling that was to be performed following 24-hour IA sampling that terminated that morning. Upon arrival, walked through the former mill and new construction apartment building prior to Excel personnel returning with equipment to perform sub-slab soil gas sampling. Noticed that the VIMS barrier had been spread out in tenant space where concrete and soil with little gravel were previously present (Photo 1). I pulled aside VIMS barrier and observed that these issues were still present (Photos 2 & 3). Sent email to Aaron Long with Excel Engineering letting him know what I had found prior to VIMS barrier being taped up. Aaron & Camden from Excel arrived on-site approximately 12:45 and I showed them material under barrier I had pointed out during previous Site Inspections (there should be 4-inches of washed gravel), and Aaron indicated that he had told superintendent that this needed to be addressed. Excel personnel exposed sub-slab sampling point in former mill building and began setting up sampling equipment and shroud for helium leak check. It was not until after leak check had begun that I realized the Summa Canister was not also being leak checked which I brought to their attention as the entire sampling train should be tested. Due to the quick/connect setup of the Summa cannister and sampling assembly (no valve), it was not possible to test the current setup without the sampling process beginning. After discussing, it was determined that sub-slab testing would be performed at a later date once the correct sampling equipment had been obtained. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 07/06/2022 11:21 AM Page 5 of 6 Photo 2: Hardened concrete with some soil visible after VIMS barrier pulled aside. Photo 3: Hardened concrete and soil from different angle. Horizontal VIMS suction line covered in mesh sock visible on left side of photo. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 07/06/2022 11:21 AM Page 6 of 6 Photo 4: Materials stored in room off hallway observed shortly after IA sampling completed. Acetone can is half full and did not have a lid on it. Photo 5: Did not notice until the helium check had begun that the Summa cannister was not present below the shroud. With the fittings provided on the Summa cannister (quick disconnect), there was no way to leak check the entire sampling train. As a result, sub-slab soil gas sampling was postponed until the correct sampling equipment was obtained.