HomeMy WebLinkAbout20121018DryCleanSpot_PICDry Clean Spot Compliance Inspection
1142 North Main St. October 18, 2012
Fuquay-Varina, NC 27526 JLK
(919) 557-4800 Page 1 of 4
Picture 1: Dry Clean Spot was established in 2008.
Picture 3: The rear view of the dry cleaning
equipment shows pumps and separator water
collection containers stored spill containment.
Picture 2: Marvel PS-65 petroleum transfer (65-lb.
capacity) washer and two Marvel PC-55 (55-lb.
capacity) solvent reclaimer dryers are installed in
one large metal spill containment pan.
Picture 4: The dry cleaning equipment is clearly
posted with leak inspection and repair information.
Washer
Reclaimer dryers
Dry Clean Spot Compliance Inspection
1142 North Main St. October 18, 2012
Fuquay-Varina, NC 27526 JLK
(919) 557-4800 Page 2 of 4
Picture 5: Kleen-Rite solvent filter system consists
of three filtering columns that contain six carbon
cartridge filters each.
Picture 7: Solvent and wastewater treatment unit
(WWTU) filter change log was posted on the wall
adjacent solvent filter system. The most recent
WWTU filter change occurred on July 15, 2012.
Picture 6: The Kleen-Rite solvent filtering system
is installed within a metal spill containment pan.
Picture 8: Galaxy Mister, WWTU, is located in
the spill containment pan that is installed under
and around the dry cleaning machines. The
misting nozzle is mounted on the roof.
Dry Clean Spot Compliance Inspection
1142 North Main St. October 18, 2012
Fuquay-Varina, NC 27526 JLK
(919) 557-4800 Page 3 of 4
Picture 9: Two complete sets of replacement
filters for the Galaxy Mister were observed on the
day of the inspection.
Picture 11: A 55-gallon drum approximately ½ full
of solvent waste is stored in spill containment with
a 66 gallon capacity. The spill containment was
equipped with a 55-gallon expandable bladder.
Picture 10: Clothes press vacuum pump
condensate is collected and treated in the Galaxy
Mister. The pump is located in the boiler room.
Picture 12: A partially full 55-gallon drum of
Ecosolve dry cleaning solvent was stored in spill
containment with a 66 gallon capacity.
Dry Clean Spot Compliance Inspection
1142 North Main St. October 18, 2012
Fuquay-Varina, NC 27526 JLK
(919) 557-4800 Page 4 of 4
Picture 13: An emergency information sign was
clearly posted near a telephone at the front of the
facility.
Picture 15: The facility collects spotting table
waste an periodically empties the collection
container into the hazardous waste drums.
Picture 14: Absorbent, emergency spill, clean-up
materials were stored near the Marvel PS-55.
Picture 16: Reclaimer dryers are clearly posted
with precautions for working with DF2000 (or
Ecosolve), which is a combustible solvent with a
flashpoint of 142° F.