Loading...
HomeMy WebLinkAbout20090811DryCleanSpot_PICDry Clean Spot Outreach Visit 1142 N. Main St. August 11, 2009 Fuquay-Varina, NC 27526 SCG/CJG (919) 557-4800 Page 1 of 3 Picture 1: Front view of Dry Clean Spot looking from the parking lot along 1142 N. Main St. The Sprint store is located adjacent to the facility on the right and Blalock Properties LLC Real Estate Firm is adjacent to the left. Picture 3: Rear view of Marvel PS-65 petroleum dry cleaning machine showing the connection with the separate filtration system. Also pictured, to the right of the washer, are the two reclaimers with associated separator water receptacles, and the mister. Picture 2: Transfer system: one Marvel Petrol Dry PS-65 (65-lb capacity) petroleum washer and two Marvel Petrol Dry PC-55 (55-lb capacity) reclaimers with refrigerated condensers were installed in January 2008. Spill containment is utilized under the machines. Picture 4: One separator water collection bucket was located within spill containment behind each of the two reclaimer units. The collection buckets were not covered and water was being discharged into them at the time. Dry Clean Spot Outreach Visit 1142 N. Main St. August 11, 2009 Fuquay-Varina, NC 27526 SCG/CJG (919) 557-4800 Page 2 of 3 Picture 5: Petroleum filter housing. The filters are connected to the dry cleaning machine. The petroleum is apparently piped to the tank under the washer, through the filters, and then into the drum. Also pictured are spill cleanup materials stored under the filters. Picture 7: One large bottle of picrin was unopened and sitting in its box. The bottle labeled “solvent” contained DF2000, which was being used as a spotting agent. One small bottle labeled picrin was observed by the spotting table and was nearly empty. The owner stated that picrin was rarely used. Picture 6: Waste from the spotting procedures is collected in the receptacle at the foot of the pedestal and is rarely emptied. There was a small amount of muck and some garbage covering the bottom of the container. The owner was advised that the receptacle should periodically be emptied into the hazardous waste drum. Picture 8: Vacuum pump is located in the boiler room. Vacuum pump condensate is collected in the plastic container on the floor beside the vacuum and added to the waste water treatment unit as needed. Dry Clean Spot Outreach Visit 1142 N. Main St. August 11, 2009 Fuquay-Varina, NC 27526 SCG/CJG (919) 557-4800 Page 3 of 3 Picture 9: The wastewater treatment unit is a galaxy mister. The owner was advised that the unit should be in secondary containment and be covered. The discharge pipe from the mister unit was routed through the ceiling. Also pictured is an empty solvent storage drum. Picture 10: Drums were stored along the wall adjacent to the dry cleaning machines. The waste drum contained dry filters. The solvent drum contained a small amount of solvent and should be in spill containment.