HomeMy WebLinkAbout17020_Chronicle Mill_SIR_20211202 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 04/29/2022 11:47 AM I. Inspection Information Date & Time: 12/02/2021 3:01 PM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Jim Reilly- Site Superintendent/Armada Associates, Aaron Long- Excel Engineering Location: Lat: 35.24312799320219, Long: -81.03393900568274, Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 2 of 7 II. Project Information Number: 17020-13-036 Name: Chronicle Mill Address: 96 East Catawba St. City: Belmont County: Gaston III. Environmental Current Use of Property: Mixed Use Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: New apartment building - Inspected VIMS risers, and monitoring points, sub- slab components were not visible as concrete slab had already been poured. There were a couple of monitoring points that were not visible and would have to be searched for (Photos 1-4). Former mill building – Walked through building to check on progress of building, and VIMS (Photos 5 and 6). Summary: N/A Summary: Renovated former mill building (mixed use), and new construction apartment building. Summary: Consistant with EMP and site construction activities. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No risk to the public observed at the time of the Site Inspection. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Former mill building in the foreground, with new construction apartment building at rear of photo. Site Inspection performed to inspect progress on new apartment building construction. Inspected VIMS risers, and monitoring points within the apartment building. There were a couple of monitoring points that had not been located that will be looked for. In addition, walked through former mill building while on-site and took photos of current status. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 5 of 7 Photo 2: Sub-slab monitoring point prior to cleaning off and removing protective tape. Photo 3: Barrier sealed to sub-slab monitoring point below concrete slab. Low VOC caulk or mortar to be used to seal top flush with concrete floor slab. Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 6 of 7 Photo 4: PVC VIMS riser stub-up within interior wall. Photo 5: Exposed sub-slab suction piping within retail space in Former mill building Brownfields Inspection Report: Chronicle Mill, 17020-13-036 12/02/2021 3:01 PM Page 7 of 7 Photo 6: Sub-slab suction piping with sock filter. Photo 7: This portion of retail area will need a significant amount of work before vapor barrier can be installed.