Loading...
HomeMy WebLinkAbout22016_Quality Products_SIR_2022.04.13 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 04/14/2022 8:27 AM I. Inspection Information Date & Time: 04/13/2022 2:11 PM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Andrew Besu - Hart & Hickman Location: Lat: 35.2189342, Long: -80.8610783, Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 2 of 7 II. Project Information Number: 22016-18-060 Name: Quality Products Co Address: 1513, 1515, 1521 S. Mint Street City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Commercial/Retail Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Observed smoke testing of VIMS barrier within 1515 S. Mint Street. EPRO VB20 vapor barrier installed with seams and penetrations sealed with GeoSeal prior to testing (Photo 2). Three smoke tests were performed to confirm there were no leaks in the vapor barrier (Photos 3-6). VIMS components not installed within 1513 S. Mint Street at the time of the Site Inspection (Photo 7). Summary: N/A Summary: Renovated 1-story brick building (Photo 1) which is divided into two sections, 1515 S. Mint St. on the southwestern end of building (Photos 2-6), and 1513 S. Mint St. on the northeastern end of the building (Photo 7). Summary: N/A Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No risk to the public observed at the time of the site inspection. Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: View of building facing south across S. Mint Street, with 1513 S. Mint St. in the foreground, and 1515 S. Mint St. in the background. Performed Site Inspection during H&H smoke testing of VIMS barrier within unit 1515 S. Mint St. VIMS barrier and risers appeared in good condition. Smoke testing was performed in three separate locations within the unit and only very minor barrier leakage was observed that was immediately resprayed/sealed (Photos 3 & 4). Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 5 of 7 Photo 2: Interior of 1515 S. Mint St. EPRO Geo-Seal EV20 Vapor barrier installed, with Geo-Seal sprayed seams. Photo 3: Smoke Test being performed on vapor barrier. Three separate tests were performed, within 1515 S. Mint St. space. Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 6 of 7 Photo 4: Respray of barrier penetration where smoke was detected during testing. Photo 5: Seam between two sheets of EPRO Geo-Seal EV20, with spray applied sealing strip. Brownfields Inspection Report: Quality Products Co, 22016-18-060 04/13/2022 2:11 PM Page 7 of 7 Photo 6: Example of sealed utility bank. Photo 7: Interior of 1513 S. Mint Street unit where utilities and VIMS constituents haven’t been installed yet.