HomeMy WebLinkAbout22023_Woodlawn Green_SIR_20220404DWM Brownfields Inspection Report
Submitted By: jkslaughter_ncdenr
Submitted Time: 04/04/2022 10:16 AM
I.Inspection Information
Date & Time: 04/04/2022 9:18 AM Inspection Type: Meeting
Brownfields Staff:
Kevin Slaughter
Other Personnel:
Shannon Sharp - Hart & Hickman
Location:
Lat: 35.1774379, Long: -80.8826121,
Brownfields Inspection Report: Woodlawn Green (RN), 22023-18-060
04/04/2022 9:18 AM
Page 2 of 6
II.Project Information
Number: 22023-18-060 Name: Woodlawn Green (RN)
Address: 200, 202, 204, 206,
208, 210 E. Woodlawn Rd;
5000, 5019, 5111 Nations
Crossing Rd
City: Charlotte
County: Mecklenburg
III. Environmental
Current Use of Property: Residential
Structures on Property: Existing Structures Violation: No
Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No
Use of Surface Water or Groundwater: Not Observed Water Use Violation: No
Exposed Soils: Observed Exposed Soils Violation: No
Summary: During Site Inspection, observed sub-slab stone, VaporVent. PVC risers and
monitoring point stub-ups, and VB20 that has been installed previously (Photos 1-5).
VB20 vapor barrier will wrap over stone and vapor vent,to become sub-slab VIMS barrier.
Summary: N/A
Summary: On-site to observe first townhome building (Building 1020) gravel and sub-slab
VaporVent installation inspection.
Summary: Consistant with EMP.
Brownfields Inspection Report: Woodlawn Green (RN), 22023-18-060
04/04/2022 9:18 AM
Page 3 of 6
Use of Basements: Not Observed Basement Violation: No
Storage of Chemicals: Not Observed Chemical Violation: No
Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No
Current Exposure to Public/Public Risk:
Summary: N/A
Summary: N/A
Condition:
Summary: N/A
No risk to the public observed at the time of the Site Inspection.
Brownfields Inspection Report: Woodlawn Green (RN), 22023-18-060
04/04/2022 9:18 AM
Page 4 of 6
IV.Inspector Comments
V.PHOTOGRAPHS
Photo 1: View of townhome footprint (5 individual units) being inspected. Vapor vent that will
be wrapped over gravel and sealed visible in photograph.
Site Inspection performed to observe stone and sub-slab piping (VaporVent) inspection
being performed by H&H. No issues identified with VIMS components - exposed barrier,
washed stone thickness VaporVent layout, or VIMS risers and monitoring points on the 5-
unit townhome footprint.
Brownfields Inspection Report: Woodlawn Green (RN), 22023-18-060
04/04/2022 9:18 AM
Page 5 of 6
Photo 2: General layout of sub-slab components.
Photo 3: Close-up of VaporVent.
Brownfields Inspection Report: Woodlawn Green (RN), 22023-18-060
04/04/2022 9:18 AM
Page 6 of 6
Photo 4: Typical VaporVent to PVC riser transition.
Photo 5: Monitoring point riser to be accessed from exterior of garage.