Loading...
HomeMy WebLinkAbout09044_Willard Lead_SIR_20220202 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 02/04/2022 10:42 AM I. Inspection Information Date & Time: 02/02/2022 9:15 AM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter Other Personnel: Edwin Marquez - Service Manager Location: Lat: 35.1994821, Long: -80.8697581, Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 2 of 7 II. Project Information Number: 09044-05-060 Name: Willard Lead Address: 101 New Bern St City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: Unknown Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Able to access western apartment building rooftop where active VIMS fan was operating as designed (Photo 2). Roof top fan/riser on eastern building (Photo 3) will require a ladder to access and Mr. Marquez had limited time to look for VIMS components before an appointment. Unable to verify locations of western VIMS ground level riser although maintenance and electrical rooms below the rooftop riser were thoroughly checked. I believe eastern building riser was located although there was no labeling, low vacuum alarm or sample port shown in design drawings (Photos 4 and 5). This will be confirmed on follow-up site inspection in addition to accessing eastern roof- top fan and making an additional attempt to locate western ground floor VIMS riser. Summary: N/A Summary: High density apartment buildings present on the property. Summary: N/A Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No risk of exposure observed during the Site Inspection. Only able to check operation of one fan during visit due to limited availability of Mr. Marquez Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Western apartment building, intersection of Foster Ave. and New Bern St. Following the site visit, Summit Engineering was contacted by email on 2/8/2022 to request a site meeting and to provide as-built drawings of VIMS. Summit Engineering has not been involved with the project since 2013, there are no As-Built drawings available, and the reports they sent in their email response on 2/8/2022 were already in DEQ’s files. Patrick Lowery with Summit contacted me by phone, and I let him know I was going to perform a follow-up inspection at the property when Mr. Marquez had an opening, and I would put together a list of any deficiencies with the system that Mr. Lowery agreed would be addressed. The follow-up site visit, list of items to be addressed, proposed timeline, etc. will be contained in a Follow-up Site Inspection Report. Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 5 of 7 Photo 2: Rooftop view of VIMS riser and fan on western building. Photo 3: Photograph of rooftop riser on eastern building. Will have to access with ladder on future visit. Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 6 of 7 Photo 4: Lower portion of suspected VIMS riser within eastern building. As noted previously, no labeling, sampling port, or low vacuum alarm installed. Design drawings also show active fan near floor slab. However, active fans are located above the roof on both VIMS risers. Brownfields Inspection Report: Willard Lead, 09044-05-060 02/02/2022 9:15 AM Page 7 of 7 Photo 5: Upper portion of suspected VIMS riser within eastern apartment building.