HomeMy WebLinkAbout19032_Central Ave Apts_ SIR_2022.01.20 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 01/21/2022 8:45 AM I. Inspection Information Date & Time: 01/20/2022 12:12 PM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter Other Personnel: Ms. Tia Persons - Property manager. Location: Lat: 35.2204671, Long: -80.8063003, Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 2 of 7 II. Project Information Number: 19032-15-060 Name: Central Avenue Apts (RN) Address: 2007, 2013, 2027 Central Ave City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Mixed Use Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: There is an active VIMS located within both buildings. The VIMS fans on the western building are mounted on the roof. Fans for eastern building are located within the attic space. Unable to access fans during the Site Inspection as the building superintendent was on vacation. Took vacuum influence measurements at representative sub-slab monitoring points to confirm system operating as designed (see Inspector Comments and Photos 4-7). Summary: N/A Summary: There are two apartment buildings on the property. The western building is Mixed Use with retail and leasing office/gym/common area and apartments on first floor and apartments only on floors 2-4. The eastern building is strictly apartments (3 floors). Summary: N/A Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No exposure to the public observed at the time of the site inspection. Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: West side of four-story mixed-use building. Retail space located on southern side facing Central Avenue. Inspection was made to confirm that active VIMS is operating as designed. Although unable to access active rooftop fans on the western building, or the attic fans in the eastern building, vacuum influence measurements were measured at four representative locations within the western building (leasing office, common area, tenant space, and occupied retail space. In addition, two locations within eastern building were measured (both tenant spaces). Vacuums measured during the Site Inspection ranged from 0.104 to 0.207 “WC, well above the minimum vacuum 0.016 “WC or 4 Pascals desired (see photos 4-7). Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 5 of 7 Photo 2: Currently unoccupied retail space along Central Avenue. Photo 3: Interior of unoccupied retail space. Concrete floor has been poured and utilities stubbed up. Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 6 of 7 Photo 4: Leasing office, and Common Area vacuum monitoring points following removal of hallway access covers during vacuum measurement within western building. Photo 5: Sub-slab hallway monitoring point for resident apartment unit within western building. Brownfields Inspection Report: Central Avenue Apts (RN), 19032-15-060 01/20/2022 12:12 PM Page 7 of 7 Photo 6: Vacuum measurement of resident monitoring point shown in Photo 5. Photo 7: Vacuum measurement of resident apartment within eastern building.