Loading...
HomeMy WebLinkAbout16028_Kale Bindex_SIR_2021.18.11 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 11/19/2021 10:02 AM I. Inspection Information Date & Time: 11/18/2021 11:49 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Alexis McKenzie - H&H Location: Lat: 35.2117554, Long: -80.8627538, Brownfields Inspection Report: Kale-Bindex (2000 Hawkins Street), 16028-12-060 11/18/2021 11:49 AM Page 2 of 6 II. Project Information Number: 16028-12-060 Name: Kale-Bindex (2000 Hawkins Street) Address: 2000 Hawkins Street City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Onsite during installation of active VIMS within first floor garage of each townhome within Buildings 4 and 5. These building have a previously installed sub-slab VIMS barriers which is below the concrete slab. Observed the completed interior suction piping within at least one unit within Building 4 (two suction points) and Building 5 (single suction point) during the Site Inspection (Photos 1 and 2). Garage suction piping that has been completed is stubbed up in the backyard of the respective townhome (Photo 4). Active fans, low vacuum alarms, and PVC vertical exhaust risers have not been installed yet. Summary: N/A Summary: High density 3-story townhomes. First floor of each residence consists of a garage with soil contact along rear masonry walls. In addition, the exterior wall of each building end unit also has soil contact. Summary: N/A Brownfields Inspection Report: Kale-Bindex (2000 Hawkins Street), 16028-12-060 11/18/2021 11:49 AM Page 3 of 6 Use of Basements: Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: First floor garages have soil contact along rear masonry wall, and partial side wall soil contact on end units of each building. Summary: N/A Condition: Summary: N/A TCE has been detected within a townhome during a prior sampling event at levels up to 4.8 ug/m3. The active VIMS is being installed to reduce indoor air TCE to below residential risk standards. Brownfields Inspection Report: Kale-Bindex (2000 Hawkins Street), 16028-12-060 11/18/2021 11:49 AM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Two VIMS suction point installed along left wall of garage in photo (Building 4). Site visit performed to inspect progress of active VIMS installation on Building 4 and 5 townhomes. Was only able to access a couple of the garage areas where VIMS suction piping had been installed during the site visit since many units had not been started or the homeowners were not home to grant access. As stated previously, suction piping within the units completed is routed to their respective backyards (Photo 4). Installation of the VIMS fans, low vacuum alarms and PVC risers on the suction piping had not been started at the time of the Site Inspection. Brownfields Inspection Report: Kale-Bindex (2000 Hawkins Street), 16028-12-060 11/18/2021 11:49 AM Page 5 of 6 Photo 2: Single suction point active VIMS installed along wall in photo (Building 5). Masonry wall on the right of photo is in contact with soil to the top of the wall. Photo 3: Typical Sch. 40 PVC suction point penetration through basement floor. Suction point will extract air from a sub-slab, gravel filled suction pit using an active fan. Brownfields Inspection Report: Kale-Bindex (2000 Hawkins Street), 16028-12-060 11/18/2021 11:49 AM Page 6 of 6 Photo 4: PVC suction point piping extended from garage/basement level into back yard adjacent to wood fence. Active VIMS fan and low vacuum alarm to be installed, then PVC VIMS exhaust riser will be extended above townhome roofline. Photo 5: Backyards of Building 5 townhomes. VIMS exhaust risers and fans on Building 4 and 5 had not been started at the time of the inspection.