HomeMy WebLinkAbout21047_High Point Multi Stadium_SIR2_20211117 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 11/19/2021 10:02 AM I. Inspection Information Date & Time: 11/17/2021 9:05 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Tim McKinney - City of Highpoint Location: Lat: 35.9598519, Long: -80.0123127, Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 2 of 8 II. Project Information Number: 21047-17-041 Name: High Point Multi Stadium Address: 201,206,210,215,300,305,307 Church Av.; 207,211,213,215,217,303 Gatewood Av.; 305,307 N. Elm St.; 207,209,211,216,308 Pine St.; 500,504,508,516 W. English Rd.; 204,208,210,212,214,216,218 N. Lindsay St. City: High Point County: Guilford III. Environmental Current Use of Property: Recreation/Festival Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: Yes Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Summary: Active 8-fan VIMS installed within enclosed portion of stadium, and passive VIMS installed within Ticket Booth building. During Site Inspection, checked condition of VIMS, which consists of active fans, low vacuum alarms, liquid filled U-tube manometers, and vapor pins to measure vacuum influence (Photos 2-6). Generally, the VIMS was in good condition, with the exception of missing labeling on some of the risers on the Stadium VIMS (Photo 6), and a missing passive turbine on the Ticket Booth VIMS riser (Photo 7). Summary: N/A Summary: Truist Point baseball stadium present on the brownfield’s property. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 3 of 8 Exposed Soils: Not Observed Exposed Soils Violation: No Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Summary: N/A Condition: Summary: N/A With the possible exception of the ticket booth (no exhaust turbine installed), no risk to the public observed during the Site Inspection. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 4 of 8 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: High Point Multi Stadium (Truist Point Stadium) Site visit performed because property has not previously been inspected by BPMU, and to inspect condition of the VIMS installed. Generally, the VIMS appeared in good condition with the electric fans, audible alarms, U-tube manometers, and vapor pins working as designed. There were two items that needed to be addressed based on discrepancies with the As-Built drawings submitted by EAI South. The first item is that additional riser labeling needs to be installed on the stadium VIMS risers (Photo 6), with the second item being the Ticket Booth building did not have a rooftop passive turbine installed as identified in the As-Built drawings. Although it was confirmed that one of the two PVC risers present on the Ticket Booth building was a sewer vent line, the inspector is not certain that the other riser is part of the VIMS (it is not labeled, turbine was not installed, there is no location within the building where the riser is visible, and its location is not correct per the Ticket Booth rooftop As-Built drawing (Photo 8). Recommend confirmation testing be performed by applying a vacuum to the riser (Shop-vac or other temporary fan) and measuring vacuum influence by checking sub-slab vapor pins within the Ticket Booth building. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 5 of 8 Photo 2: VIMS suction point. Valve, low vacuum alarm, U-tube manometer and labeling visible in photo. Photo 3: VIMS access panel. All components present. Riser labeling present below valve, and not visible in photo. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 6 of 8 Photo 4: Checking vacuum influence accross hallway from weight room suction point where some water was present in suction line (audible, and u-tube manometer vacuum was fluctuating). Vapor pin indicated 0.09 “WC or 22.4 pascals of vacuum influence. Photo 5: Typical roof mounted electric VIMS fan. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 7 of 8 Photo 6: PVC riser adjacent to steel I-Beam (both painted gray) supporting metal roof. No VIMS labeling observed on exposed riser piping. Brownfields Inspection Report: High Point Multi Stadium, 21047-17-041 11/17/2021 9:05 AM Page 8 of 8 Photo 7: Climbing onto Ticket Booth Roof to check VIMS riser. Photo 8: No turbine vent on VIMS riser. Determined PVC riser on the left is a sewer vent. It appears the PVC riser on the right is the VIMS, however, there is no turbine or labeling, and it is not in the correct location according to rooftop As-Built Drawing.