Loading...
HomeMy WebLinkAboutEMP_General Baptist State Convention Property_20211206 signEnvironmental Management Plan General Baptist State Convention Property Brownfields Project No. 24030-20-092 603 S. Wilmington Street, 112 and 114 E. Lenoir Street Raleigh, North Carolina H&H Job No. NAP-001 Revised December 2, 2021 hart � hickman SMARTER ENVIRONMENTAL SOLUTIONS #C-1269 Engineering #C-245 Geoloav 2923 South Tryon Street, Suite 100 3921 Sunset Ridge Rd, Suite 301 Charlotte, NC 28203 Raleigh, NC 27607 www.harthickman.com 704.586.0007 main 919.847.4241 main Completed EMP Template Form CONTENTS Tables Table 1 Summary of Soil Analytical Data Table 2 Summary of Groundwater Analytical Data Table 3 Summary of Vapor Intrusion Analytical Data FiL,rures Figure 1 Site Location Map Figure 2 Sample Location Map Appendices Appendix A Redevelopment Plans Appendix B Grading Plan and Cut -Fill Analysis hart hickman SMARTER ENVIRONMENTAL SOLUTIONS NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the North Carolina Brownfields Program at the direction of a Brownfields project manager. The EMP is a typical requirement of a Brownfields Agreement (BFA). Its purpose is to clarify actions to be taken during the demolition and construction at Brownfields properties in an effort to avoid delays in the event of the discovery of new contamination sources or other environmental conditions. The EMP provides a means to document redevelopment plans and environmental data for each applicable environmental medium to inform regulatory -compliant decision -making at the site. As much detail as possible should be included in the EMP, including contingency planning for unknowns. Consult your project manager if you have questions. Prospective Developers and/or their consultants must complete and submit this form and all pertinent attachments, see checklist below, to their Brownfields project manager prior to any earthmoving or other development -related activities that have the potential to disturb soil at the Brownfields Property, including demolition. For the resultant EMP to be valid for use, it must be completed, reviewed by the program, signed by all parties working on the project, and approved by the Brownfields project manager. Failure to comply with the requirements of the EMP could jeopardize project eligibility, or in the event of a completed agreement, be cause for a reopener. The EMP is valid only for the scope of work described herein and must be updated to be applicable for new phases of redevelopment or after significant changes in applicable regulatory guidance. Voluntary Metrics Tab The NC Brownfields Program updates estimated capital investment (from the Brownfields Property Application) and estimated jobs created (from the Brownfields Agreement) whenever possible. As a voluntary measure, you may opt to complete the below information for capital investment and jobs created as estimated by your final redevelopment plans for the Brownfields Property: 1. Estimated capital investment in redevelopment project: Click or tap here to enter text. 2. Estimated jobs created: a. Construction Jobs: Approximately 200-250 b. Full Time Post -Redevelopment Jobs: Approximately 50-60 EMP Version 2, January 2021 Table of Contents NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN ........................... 1 GENERAL INFORMATION........................................................................................................................ 4 COMMUNICATIONS................................................................................................................................ 4 NOTIFICATIONS TO THE BROWNFIELDS PROGRAM............................................................................... 5 REDEVELOPMENT PLANS........................................................................................................................ 5 CONTAMINATED MEDIA......................................................................................................................... 7 PART1. Soil......................................................................................................................................... 7 PART 2. GROUNDWATER................................................................................................................. 18 PART 3. SURFACE WATER.................................................................................................................. 20 PART 4. SEDIMENT............................................................................................................................ 21 PARTS. SOIL VAPOR......................................................................................................................... 21 PART6. SUB -SLAB SOIL VAPOR........................................................................................................ 22 PART7. INDOOR AIR......................................................................................................................... 22 VAPOR INTRUSION MITIGATION SYSTEM............................................................................................. 23 CONTINGENCY PLAN — encountering unknown tanks, drums, or other waste materials ..................... 24 POST -REDEVELOPMENT REPORTING..................................................................................................... 26 APPROVAL SIGNATURES....................................................................................................................... 28 2 EMP Version 2, January 2021 So that the EMP provides value in protecting brownfields eligibility and public health, the preparer shall ensure that the following steps have been completed prior to submitting the EMP for review. Any EMP prepared without completing these steps is premature. ® Site sampling and assessment that meets Brownfields' objectives is complete and has been reviewed and approved by the Brownfields Project Manager. ® Specific redevelopment plans, even if conceptual, have been developed for the project, submitted and reviewed by the Brownfields Project Manager. Please submit, along with the completed EMP form, the following attachments, as relevant and applicable to the proposed redevelopment: ® A set of redevelopment plans, including architectural/engineering plans, if available; if not conceptual plans may suffice if updated when detailed plans are drafted. ❑ A figure overlaying redevelopment plans on a map of the extent of contamination for each media. ® Site grading plans that include a cut and fill analysis. ❑ A figure showing the proposed location and depth of impacted soil that would remain on site after construction grading. ❑ Any necessary permits for redevelopment (i.e. demolition, etc.). ❑ A detailed construction schedule that includes timing and phases of construction. ® Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas, etc.) applicable to the proposed redevelopment. ® Figures with the sampling locations and contamination extents for each impacted media applicable to the proposed redevelopment. ❑ A full final grade sampling and analysis plan, if the redevelopment plan is final. ❑ If known, information about each proposed potential borrow soil source, such as aerial photos, historic site maps, historic Sanborn maps, a site history, necessary for brownfields approval. ❑ Information and, analytical data if required, for quarries, or other borrow sources, detailing the type of material proposed for importation to the Brownfields Property. EMP Version 2, January 2021 ❑ A work plan for the sampling and analysis of soil to be brought onto the Brownfields Property. Refer to Issue Resolution 15 in Brownfields Program Guidelines. ❑ A map of the Brownfields Property showing the location of soils proposed for export and sampling data from those areas. ❑ If a Vapor Mitigation System is required by the Brownfields Program, the Vapor Intrusion Mitigation System (VIMS) plan will be signed and sealed by a NC Professional Engineer. The VIMS Plan may also be submitted under separate cover. Date: 12/2/2021 GENERAL INFORMATION Revision Date (if applicable): :lick or tap to enter a date. Brownfields Assigned Project Name: General Baptist State Convention Property Brownfields Project Number: 24030-20-092 Brownfields Property Address: 603 S. Wilmington Street and 112 and 114 E. Lenoir Street, Raleigh, Wake County, North Carolina Brownfields Property Area (acres): 0.51 acres Is Brownfields Property Subject to RCRA Permit? ....................... ❑ Yes ® No If yes enter Permit No.: Click or tap here to enter text. Is Brownfields Property Subject to a Solid Waste Permit............ ❑ Yes ® No If yes, enter Permit No.: Click or tap here to enter text. COMMUNICATIONS A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the EMP shall be maintained at the Brownfields Property during redevelopment activities. NOTE, THE EMP DOES NOT TAKE THE PLACE OF A SITE -SPECIFIC HEALTH AND SAFETY PLAN. Prospective Developer (PD): Narsi Development Raleigh, LLC Contact Person: Mr. Deven Patel Phone Numbers: Office: (704) 400-6020 Email: Deven.Patel@narsi.com Contractor for PD: To Be Determined Contact Person: 'ick or tap here to enter text. Phone Numbers: Office: Click or tap hereto enter text. 4 EMP Version 2, January 2021 Mobile: Click or tap here to enter text. Mobile: Click or tap here to enter text. Email: Click or tap here to enter text. Environmental Consultant: Hart & Hickman, PC Contact Person: Mr. Justin Ballard Phone Numbers: Office: (919) 847-4241 Mobile: (252) 548-9191 Email: iballardCcDharthickman.com Brownfields Program Project Manager: Ms. Sharon Eckard Phone Numbers: Office: (919) 707-8379 Mobile: (919) 609-2617 Email: sharon.eckardCDncdenr.eov Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch, Hazardous Waste, Solid Waste): Click or tap here to o +or +o + NOTIFICATIONS TO THE BROWNFIELDS PROGRAM Written advance Notification Times to Brownfields Project Manager: Check each box to accept minimum advance notice periods (in calendar days) for each type of onsitetask: On -site assessment or remedial activities: .................................................... 10 days Prior Construction or grading start: .......................................................................... 10 days Prior Zl Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously unknown contamination: ................................................................................ Within 48 hours Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in area of contamination, ventilation of work zones): ................................... Within 48 hours Installation of mitigation systems: ................................................................ 10 days Prior ❑ Other notifications as required by local, state or federal agencies toimplement redevelopment activities: (as applicable): ................................................................................. Within 30 days REDEVELOPMENT PLANS 1) Type of Redevelopment (check all that apply): ❑Residential ❑Recreational ❑Institutional ❑Commercial ®Office ❑Retail ❑ Industrial ®Other specify: The PD plans to develop the Site as a hotel with office space and associated parking. 2) Check the following activities that will be conducted prior to commencing earth -moving activities 5 EMP Version 2, January 2021 at the site: ® Review of historic maps (Sanborn Maps, facility maps) ® Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc. ❑ Interviews with employees/former employees/facility managers/neighbors 3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if detailed plans are not available. EMP review without such information would be premature): Provide brief summary of redevelopment plans, including demolition, removal of building slabs/pavement, grading plans and planned construction of new structures: Redevelopment plans for the General Baptist State Convention Brownfields property include razing the existing Site building and construction of a 12-story hotel totaling approximately 183,000 gross square foot (sq ft), and a parking garage (floors 2 through 5) totaling approximately 76,000 gross sq ft. Final grade (i.e., ground level) will consist of limited surface parking and the hotel lobby with amenity and office space. A copy of the current redevelopment Site plan is included in Appendix A. 4) Do plans include demolition of structure(s)?: ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements, including without limitation those related to lead and asbestos abatement that are administered by the Health Hazards Control Unit within the Division of Public Health of the North Carolina Department of Health and Human Services. If available, please provide a copy of your demolition permit. 5) Are sediment and erosion control measures required by federal, state, or local regulations? ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements. If soil disturbance is necessary to install sediment and erosion control measures, they may not begin until this EMP is approved. 6) Which category of risk -based screening level is used or is anticipated to be specified in the Brownfields Agreement? Note: If children frequent the property, residential screening levels shall be cited in the Brownfields Agreement for comparison purposes. ❑ Residential ® Non -Residential or Industrial/Commercial 7) Schedule for Redevelopment (attach construction schedule): a) Construction start date: 1/1/2022 b) Anticipated duration (specify activities during each phase): Redevelopment activities are expected to take up to approximately 22 months to complete. c) Additional phases planned? ❑ Yes ® No EMP Version 2, January 2021 If yes, specify the start date and/or activities if known: Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. d) Provide the planned date of occupancy for new buildings: To be determined. CONTAMINATED MEDIA Please fill out the sections below, using detailed site plans, if available, or estimate using known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new construction onto figure showing contaminated soil and groundwater locations. 1) Contaminated Media on the Brownfields Propert Part 1. Soil: .............................................................. ® Yes ❑ No ❑ Suspected ❑ Unknown Part 2. Groundwater: ............................................ ® Yes ❑ No ❑ Suspected ❑ Unknown Part 3. Surface Water: .......................................... ❑ Yes ® No ❑ Suspected ❑ Unknown Part 4. Sediment: ................................................... ❑ Yes ® No ❑ Suspected ❑ Unknown Part 5. Soil Vapor: .................................................. ® Yes ❑ No ❑ Suspected ❑ Unknown Part 6. Sub -Slab Soil Vapor: .................................. ❑ Yes ® No ❑ Suspected ❑ Unknown Part 7. Indoor Air: ................................................... ❑ Yes ❑ No ❑ Suspected ® Unknown 2) For the Area of Proposed Redevelopment on the Brownfields Property, attach tabulated data summaries for each impacted media and figure(s) with sample locations. PART 1. Soil 1) Known or suspected contaminants in soil (list general groups of contaminants): Soil sampling has been completed at the Brownfields property as part of assessment activities documented in Hart & Hickman, P.C.'s (H&H's) Brownfields Assessment Report dated October 15, 2020. A tabular summary of the soil analytical data in comparison to the DEQ's Inactive Hazardous Sites Branch (IHSB) Preliminary Soil Remediation Goals (PSRGs) is included as Table 1 and soil sample locations are shown in Figure 2. 7 EMP Version 2, January 2021 Volatile Organic Compounds (VOCs) Laboratory analytical results indicated low levels of the VOC acetone (up to 0.109 milligrams per kilogram [mg/kg]) were detected in soil samples SB-1 and SB-2 at concentrations above the laboratory method detection limits, but well below the Industrial/Commercial PSRG. Semi -Volatile Organic Compounds (SVOCs) No SVOCs were detected at concentrations above laboratory method detection limits. Metals As expected, naturally occurring levels of several metals were detected at concentrations above laboratory method detection limits. Of the metals detected, arsenic was detected at a concentration of 7.61 mg/kg in the soil sample collected from BG-1, which is above the Industrial/Commercial PSRG but within published background levels for North Carolina soils. No other metals were detected at concentrations exceeding Industrial/Commercial PSRGs. 2) Depth of known or suspected contaminants (feet): 0 to 2 ft below ground surface (bgs) 3) Area of soil disturbed by redevelopment (square feet): Based on the grading plan (Appendix B), approximately 30,500 sq ft is expected to be disturbed during redevelopment activities. 4) Depths of soil to be excavated (feet): Proposed grading activities are expected to include excavations of up to approximately 13 ft bgs for installation of municipal water and stormwater management infrastructure. Additional soil disturbance activities include installation of caisson foundation structures to depths of up to approximately 50 ft bgs. The final depths of the caissons will be determined in the field during construction but are generally expected to be installed at the bearing elevations shown on the Ground Level Foundation Plan included in Appendix A. 5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan): Up to approximately 700 cubic yards of soil are planned to be excavated and re -used on -Site as beneficial fill during grading activities. 6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants: Excavation of impacted soil is not anticipated. If impacted soil is encountered, it will be managed as noted in Part 1.A. 7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: Excavation of impacted soil is not anticipated. EMP Version 2, January 2021 Part 1.A. MANAGING ONSITE SOIL If soil is anticipated to be excavated from the Brownfield Property, relocated on the Brownfields Property, or otherwise disturbed during site grading or other redevelopment activities, please provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are acceptable, if only preliminarydata available). 1) HAZARDOUS WASTE DETERMINATION: a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous Waste Section under 40 CFR Part 261.31-261.35?....................................... ❑Yes ®No ❑ If yes, explain why below, including the level of knowledge regarding processes generating the waste (include pertinent analytical results as needed). Click or tap here to enter text. ❑ If yes, do the soils exceed the "Contained -Out" levels in Attachment 1 of the North Carolina Contained -In Policy? ................................................. ❑ Yes ❑ No b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE CONTAINED -OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED -IN POLICYTHE SOIL MAY NOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. c) Does the soil contain a CHARACTERISTIC WASTE? .................................... ❑ Yes ® No ❑ If yes, mark reason(s) why below (and include pertinent analytical results). ❑ Ignitability Click or tap here to enter text. ❑ Corrosivity Click or tap here to enter text. ❑ Reactivity Click or tap here to enter text. ❑ Toxicity Click or tap here to enter text. ❑ TCLP results Click or tap here to enter text. ❑ Rule of 20 results (20 times total analytical results for an individual hazardous constituent on TCLP list cannot, by test method, exceed regulatory TCLP standard) ick or tap h^-^ *o enter text. ® If no, explain rationale: Soil analytical data does not indicate detections capable of exceeding toxicity characteristic leaching procedure (TCLP) criteria using the Rule of 20. d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAYNOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. EMP Version 2, January 2021 2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in place with low permeability barrier, removed to onsite location and capped, removed offsite): ❑ Preliminary Health -Based Residential SRGs ® Preliminary Health -Based Industrial/Commercial SRGs ® Division of Waste Management Risk Calculator (For Brownfields Properties Only) ❑ Site -specific risk -based cleanup level. Please provide details of methods used for determination/explanation. '< or tap here to enter text. Additional comments: Click or _ __ — _­_._ ­_.+ 3) If known impacted soil is proposed to be reused within the Brownfields Property Boundary, please check the measures that will be utilized to ensure safe placement and documentation of same. Please attach a proposed location diagram/site map. ❑ Provide documentation of analytical report(s) to Brownfields Project Manager ❑ Provide documentation of final location, thickness and depth of relocated soil on site map to Brownfields Project Manager once known ❑ Geotextile to mark depth of fill material. Provide description of material: uicK or tap nere to enter te; ❑ Manage soil under impervious cap ❑ or clean fill ❑ ❑ Describe cap or fill: uicK or tap nere to enter text. ❑ Confer with NC BF Project Manager if Brownfield Plat must be revised (or re -recorded if actions are Post -Recordation). ❑ GPS the location and provide site map with final location. ❑ Other. Please provide a description of the measure: lick or tap here to enter text. 4) Please describe the following action(s) to be taken during and following excavation and management of site soils: Management of fugitive dust from site ® Yes, describe the method will include: The grading contractor will consider conditions such as wind speed, wind direction, and moisture content of soil during grading and stockpiling (if warranted) activities to minimize dust generation. In the unlikely event that contaminated soil is encountered during Site 10 EMP Version 2, January 2021 redevelopment that requires excavation, particular attention will be paid by contractors to implement dust control measures as needed based on Site and atmospheric conditions (i.e., by controlled water application, hydro -seeding, and/or mulch, stone, or plastic cover). Potentially impacted soil will be managed as described below. ❑ No, explain rationale: Click or tap here to enter text. Field Screening of site soil ® Yes, describe the field screening method, frequency of field screening, person conducting field screening: During soil disturbance at the Site, the workers or contractors will observe soils for evidence of potential impacted soil, such as a distinct unnatural color, strong odor, or filled or previously disposed materials of concerns (i.e., chemicals, tanks, drums, etc.). Should the above be noted during Site work, the contractor will contact the project environmental professional to observe the suspect condition. If the project environmental professional confirms that the material may be impacted, then the procedures below will be implemented. In addition, the environmental professional will contact the DEQ Brownfields project manager within 48-hours to advise that person of the condition. ❑ No, explain rationale: Click or tap here to enter text. Soil Sample Collection ❑ Yes, describe the sampling method (e.g., in -situ grab, composite, stockpile, etc.): Click or tap here to enter text. ® No, explain rationale: Collection of additional soil samples is not anticipated based on results of previous Site assessment activities. If significant soil impact is encountered during grading and/or installation or removal of utilities, excavation will proceed only as far as needed to allow grading and/or construction of the utility to continue and/or only as far as needed to allow alternate corrective measures described below. Suspect significantly impacted soil excavated during grading and/or utility line installation or removal may be stockpiled and covered in a secure area to allow construction to progress. Suspect impacted soil will be underlain by and covered with minimum 10-mil plastic sheeting. At least one representative sample of the soil will be collected for analysis of VOCs, SVOCs, and RCRA metals plus hexavalent chromium at a sample ratio that is not less than 1 sample per approximately 1,000 cubic yards of impacted soil. If the results of analysis of the sample indicate that the soil could potentially exceed toxicity characteristic hazardous waste criteria, then the soil will also be analyzed by TCLP for those compounds that could exceed the toxicity characteristic hazardous waste criteria. Refer to Part 1.0 and Part 2 for details regarding export soil (if warranted) and groundwater management procedures, respectively. Impacted soil will be handled in the manner described below based upon 11 EMP Version 2, January 2021 the laboratory analyses: If no organic compounds are detected in a sample (other than which are attributable to sampling or laboratory artifacts [subject to DEQ review and approval]) and metals are below Residential PSRGs or are consistent with Site -specific and/or published background ranges for North Carolina soils, then the soil will be deemed suitable for use as on -Site fill or as off -Site fill. The proposed location(s) for off -Site placement of soil (other than a permitted facility), other applicable off -Site information (i.e., sampling results), and the receiving facility's written approval for acceptance of the soil will be provided to DEQ for approval prior to taking the soil off -Site. ii. If detectable levels of compounds are found which do not exceed the DEQ IHSB Industrial/Commercial PSRGs (other than which are attributable to sampling or laboratory artifacts for which DEQ is the arbiter or which are consistent with Site -specific and/or published background ranges for metals in North Carolina soils) and the TCLP concentrations are below hazardous waste criteria, then the soil may be used on -Site as fill. iii. If detectable levels of compounds are found which exceed the DEQ IHSB Industrial/Commercial PSRGs (other than which are attributable to sampling or laboratory artifacts for which DEQ is the arbiter or which are consistent with Site -specific and/or published background ranges for metals in North Carolina soils [i.e., soil associated with arsenic detected in soil sample BG-1]) and the TCLP concentrations are below hazardous waste criteria, then the soil, with DEQ's prior written approval, may be used on -Site as fill below an impervious surface, or at least 2 ft of compacted clean soil. If the impacted soil with concentrations above Industrial/Commercial PSRGs is moved to an on -Site location, its location and depth will be documented, covered with a geotextile fabric so that its location can be identified if encountered in the future, and its location will be provided to DEQ and identified on the Brownfields plat (if not already recorded with the executed Brownfields Agreement). iv. Impacted soil may be transported to a permitted facility such as a Subtitle D lined landfill. Transport to another permitted facility such as an LCID or C&D landfill will require DEQ's prior written approval and comparison to site -specific concentrations from the receiving facility. If soil is transported to a permitted facility, the permitted facility's written approval to dispose of soil from the Site will be included with the final EMP report. In the unlikely event that the sample data indicates concentrations above TCLP hazardous waste criteria, then the soil must be transported off -Site to a permitted disposal facility that can accept or treat hazardous waste. V. If soil export is necessary, the procedure(s) in Part 1.C. Export Soils will be followed. If soil samples are collected for analysis, please check the applicable chemical analytes: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 12 EMP Version 2, January 2021 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Methods 6020/7471 ❑ Pesticides: Specify Analytical Method Number(s): uicK or tap nere to enter text ❑ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ® Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Specify Analytical Method Number(s): Hexavalent Chromium by EPA Method 7199 ® Check to confirm that stockpiling of known or suspected impacted soils will be conducted in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion control, prohibiting contact between surface water/precipitation and contaminated soil, and preventing contaminated runoff. Explain any variances or provide additional details as needed: lick or tap here to enter text. ❑ Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or permanent hardscape). Select chemical analyses for final grade samples with check boxes below (Check all thatapply): ❑ Volatile organic compounds (VOCs) by EPA Method 8260 ❑ Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ❑ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): Click or tap here to enter text ❑ Pesticides: Specify Analytical Method Number(s): Click or tap here t ❑ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text ❑ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Click or tap here to enter text Please provide a scope of work for final grade sampling, including a diagram of soil sampling locations, number of samples to be collected, and brief sampling methodology. Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs which should be taken from 1-2 ft below ground surface. Alternatively, indicate if a work plan for final grade sampling may be submitted under separate cover. Click or tap here to enter text. 13 EMP Version 2, January 2021 © If final grade sampling was NOT selected, please explain rationale: Based on results of assessment activities completed at the Brownfields property, surficial soils in future softscape areas (i.e., areas not covered by building foundations, sidewalks, asphalt or concrete parking areas, driveways, or other impervious surfaces) are not expected to be impacted. If significant soil impact is encountered during grading and/or installation or removal of utilities, the DEQ Brownfields Program will be contacted to discuss potential final grade sampling in the area of impacts. If soil impacts are not identified during grading and/or excavation activities, final grade sampling will not be conducted. Part 1.113. IMPORTED FILL SOIL NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL FROM THE BROWNFIELDS PROGRAM. According to the Brownfields IR 15, "Documenting imported soil (by sampling, analysis, and reporting in accordance with review and written approval in advance by the Brownfields Program), will safeguard the liability protections provided by the brownfields agreement and is in the best interest of the prospective developer/property owner." Requirements for importing fill: 1) Will fill soil be imported to the site? ................................................ ❑ Yes ❑ No ® Unknown 2) If yes, what is the estimated volume of fill soil to be imported? The need for off -Site import of fill soil is not anticipated at this time; however, should off -Site import of fill soil be warranted, see No. 7 below for details outlining the proposed plan to demonstrate import soil meets acceptable standards for the Site. 3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range of depths, please list the range.) ^IiA, — 1— horn to o ft t + 4) Provide the source of fill, including: location, site history, nearby environmental concerns, etc. Attach aerial photos, maps, historic Sanborn maps and a borrow source site history: Click or tap here to enter text. 5) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide a plan to analyze fill soil to demonstrate that it meets acceptable standards applicable to the site and can be approved for use atthe Brownfields property. The PD plans to import limited amounts of organic rich topsoil from a commercial landscape material vendor for use in proposed landscaped areas. The PD does not plan to collect samples of landscaping materials prior to placement at the site. See No. 7 below for details outlining the proposed plan to demonstrate import soil (not topsoil) meets acceptable standards to the Site. 14 EMP Version 2, January 2021 6) Please check the applicable chemical analytes for fill soil samples. (Check all that apply): ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Methods 6020/7471 ❑ Pesticides: Specify Analytical Method Number(s): ❑ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ® Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Hexavalent Chromium by EPA Method 7199 7) The scope of work for import fill sampling may be provided below or in a Work Plan submitted separately for DEQ review and approval. Attach specific location maps for in -situ borrow sites. If using a quarry, provide information on the type of material to be brought onto the Brownfields Property. The PD will follow the procedures outlined below to demonstrate import soil meets acceptable criteria for Site use. If the PD plans to import virgin fill material from a DEQ Brownfields pre -approved borrow source (such as the Wake Stone Corporation quarry located in Knightdale, North Carolina), no samples of the import material will be collected because adequate analytical data is available in the DEQ Brownfields database to demonstrate material from these facilities is suitable for use as structural fill at a Brownfields property. If fill soil (other than topsoil) is obtained from an off -Site property that is not a known permitted quarry or is recycled material from a DEQ Brownfields pre -approved borrow source, the borrow source will be sampled in general accordance with the most recent versions of the U.S. Environmental Protection Agency (EPA) Region IV Science and Ecosystem Support Division (SESD) Field Branches Quality System and Technical Procedures guidance. If the proposed borrow material is a byproduct of crushing stone (referred to as "fines") from a permitted quarry, no samples will be collected for laboratory analysis. If the proposed borrow source is soil comprised of virgin quarry material from a permitted quarry, one representative composite (and grab for VOCs) soil sample will be collected from within the active excavation area of the facility for laboratory analysis. If the proposed borrow source has not been previously developed (i.e., virgin land), soil samples will be collected for laboratory analysis at a general rate of approximately one per 1,000 cubic yards. If the borrow source property has been previously developed, soil samples will be collected for laboratory analysis at a general rate of approximately one per 500 cubic 15 EMP Version 2, January 2021 yards. Specifically, composite soil samples for any of the above scenarios will be collected using a hand auger. Each composite sample will be comprised of soil from four grab sample locations (i.e., aliquots at depths representative of cut/excavation). The composite soil samples will be collected directly into dedicated laboratory -supplied sample containers and submitted to a North Carolina certified laboratory under standard chain of custody protocols for laboratory analysis SVOCs by EPA Method 8270 and RCRA metals plus hexavalent chromium by EPA Methods 6020/7471/7199. In addition to the composite soil samples described above, one representative grab soil sample will also be collected from a location and at a depth representative of cut/excavation. The grab soil samples will be collected from undisturbed portions of soil directly into laboratory -supplied glassware and for laboratory analysis of VOCs by EPA Method 8260. The DEQ Brownfields project manager will be contacted should an alternate sampling frequency be sought for either type of borrow source property. Fill soil will be considered suitable for use at the Site if it does not contain compounds that are not located at the Brownfields property, does not contain compounds at concentrations above DEQ Industrial/Commercial PSRGs, and does not increase the risk at the Brownfields property demonstrated through use of the most current DWM Risk Calculator. DEQ approval of the analytical results will be obtained prior to transporting import soil to the Site. Part 1.C. EXPORTED SOIL NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE BROWNFIELDS PROGRAM. FAILURE TO OBTAIN APPROVAL MAY VIOLATE A BROWNFIELDS AGREEMENT CAUSING A REOPENER OR JEOPARDIZING ELIGIBILITY IN THE PROGRAM, ENDANGERING LIABILITY PROTECTIONS AND MAKING SAID ACTION POSSIBLY SUBJECT TO ENFORCEMENT. JUSTIFICATIONS PROVIDED BELOW MUST BE APPROVED BY THE PROGRAM IN WRITING PRIOR TO COMPLETING TRANSPORT ACTIVITIES. Please refer to Brownfields IR 15 for additional details. 1) If export from a Brownfields Property is anticipated, please provide details regarding the proposed export actions. Volume of exported soil, depths, location from which soil will be excavated on site, related sampling results, etc. Provide a site map with locations of export and sampling results included. Export soil is not anticipated at this time. However, should soil need to be exported from the Brownfields property during redevelopment, soil will be sampled in general accordance with the most recent versions of the EPA Region IV SESD Field Branches Quality System and Technical Procedures guidance. Samples will be collected from export soil at a rate of one (1) sample per every approximately 16 EMP Version 2, January 2021 1,000 cubic yards of export for laboratory analysis of VOCs by EPA Method 8260, SVOCs by EPA Method 8270, and RCRA metals by EPA Methods 6020/7471. SVOCs and metals will be collected as composite samples using a decontaminated stainless -steel hand auger. Soil samples will also be collected for hexavalent chromium for analysis by EPA Method 7199. The composite samples will consist of three sample aliquots that are combined to form one sample for laboratory analysis. Each aliquot will be field screened for the presence of VOCs using a calibrated photoionization detector (PID). VOC samples will be collected as grab samples using a decontaminated stainless -steel hand auger from the general area of the aliquot which exhibits the highest indication of impact during field screening. The soil samples will be placed in dedicated laboratory -supplied sample containers, covered with ice, and shipped to a North Carolina -certified laboratory under standard chain of custody protocols. DEQ approval of the analytical results will be obtained prior to transporting export soil from the Site. Based on analytical results of soil samples collected from the export soil, the soil will be transported off -Site to a suitable location. The PD will notify DEQ Brownfields of the location receiving the export soil. If not a lined Subtitle D MSW landfill, DEQ Brownfields approval and written approval from the receiving facility will be obtained prior to transporting the soil off -Site. 2) To what type of facility will the export Brownfields soil be sent? ® Subtitle D/Municipal Solid Waste Landfill (analytical program to be determined by landfill) ® Permitted but Unlined Landfill (i.e. LCID, C&D, etc.) Analytical program to be determined by the accepting Landfill; ® Landfarm or other treatment facility ® Use as fill at another suitable Brownfields Property — determination that a site is suitable will require, at a minimum, that similar concentrations of the same or similar contaminants already exist at both sites, use of impacted soil will not increase the potential for risk to human health and the environment at the receiving Brownfields property, and that record of the acceptance of such soil from the property owner of the receiving site is provided to Brownfields. Please provide additional details below. ® Use as Beneficial Fill off -site at a non-Brownfields Property - Please provide documentation of approval from the property owner for receipt of fill material. This will also require approval by the DEQ Solid Waste Section. Additional information is provided in IR 15. Please provide additional details below. 3) Additional Details: (if transfer of soil to another property is requested above, please provide details related to the proposed plans). The environmental professional will contact DEQ Brownfields to obtain DEQ Brownfields approval prior to exporting soil to a non-Brownfields property or lined Subtitle D MSW landfill. 17 EMP Version 2, January 2021 Part 1.D. MANAGEMENT OF UTILITY TRENCHES ❑ Install liner between native impacted soils and base of utility trench before filling with clean fill (Preferred) ® Last out, first in principle for impacted soils (if soil can safely be reused onsite and is nota hazardous waste), i.e., impacted soils are placed back at approximately the depths they were removed from such that impacted soil is not placed at a greater depth than the original depth from which it was excavated. ❑ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or degradation of conduit materials due to direct impact with contaminants? ❑ If yes, provide specifications on barrier materials or provide the results of this evaluation in the Vapor Mitigation Plan. Note that if vapor mitigation is planned for site buildings, utility corridors will need to be evaluated as part of mitigation designs: Click or tap here to enter text. ® If no, include rationale here: Results of soil assessment activities indicated that concentrations of detected compounds are within published background levels for North Carolina soils (metals only) and/or do not exceed Industrial/Commercial PSRGs. ❑ Unknown, details to be provided in the Vapor Mitigation Plan for site buildings Other comments regarding managing impacted soil in utility trenches: Although not anticipated, in the event contaminated soil and/or vapors are encountered in utility trenches during redevelopment activities, the trench will be evacuated and appropriate safety screening of the vapors will be performed to protect workers. If results indicate further action is warranted in response to vapors to protect workers, appropriate engineering controls (such as use of industrial fans) will be implemented. The contractor and workers will observe soil for potential impacts during utility installation activities. Evidence of potential impacted soil includes a distinct unnatural color, strong odor, or filled or previously disposed materials of concerns (i.e., chemicals, tanks, drums, etc.). Should the above be noted during utility work, the contractor will contact the project environmental professional to observe the suspect condition. If the project environmental professional confirms that the material may be impacted, then the procedures outlined Managing On -Site Soil above will be implemented. In addition, the environmental professional will contact the DEQ Brownfields project manager within 48 hours to advise that person of the condition. PART 2. GROUNDWATER 1) What is the depth to groundwater at the Brownfields Property? 18 EMP Version 2, January 2021 During groundwater assessment activities conducted at the Brownfields property, depth to groundwater was measured from approximately 30 to 32 ft bgs. 2) Is groundwater known to be contaminated by ❑onsite ®offsite ❑both or El unknown sources? Describe source(s): Groundwater assessment activities conducted at the Brownfields property have identified the presence of lead at a concentration above the DEQ 2L Groundwater Quality Standard (2L Standard). 3) What is the direction of groundwater flow at the Brownfields Property? Area topography suggests that groundwater flow is likely towards the east. 4) Will groundwater likely be encountered during planned redevelopment activities? ®Yes ❑No If yes, describe these activities: Caissons will be potentially installed to depths of up to approximately 50 ft bgs at the Site. As such, groundwater will be encountered during the installation of caissons; however, it is not anticipated that groundwater will be allowed to accumulate such that sampling or disposal is required. See below for groundwater management procedures. Regardless of the answer; in the event that contaminated groundwater is encountered during redevelopment activities (even if no is checked above), list activities for contingent management of groundwater (e.g., dewateringof groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or sampling procedures). Based on the estimated depth to groundwater, groundwater is anticipated to be encountered during installation of caissons. Although not anticipated at this time, appropriate worker safety measures will be undertaken if groundwater gathers in an open excavation within an area determined to be impacted (based on strong odor, unnatural color, sheen, etc.) during construction activities. The contractor will contact the environmental professional to observe the suspected condition. The accumulated water will be allowed to evaporate/infiltrate to the extent time for dissipation does not disrupt the construction schedule. Should the time needed for natural dissipation of accumulated water be deemed inadequate, the water will be tested for the presence of VOCs, SVOCs, and RCRA metals and disposed off -site (if impacted), or tested and discharged to the storm sewer (if not impacted above DEQ surface water standards) in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. The volume of groundwater that will require management during caisson installations is unknown, as it is largely dependent on Site -specific geological and hydrogeological conditions. The minority of drilling spoils is anticipated to be saturated soil, which will be managed as noted in Part LA. and Part 1.C. If free -flowing groundwater can be reasonably captured, it will be pumped to lined and covered roll -off containers or an aboveground tank prior to testing for the presence of VOCs, SVOCs, and RCRA metals. The groundwater will then be disposed off -Site (if impacted) or discharged to the storm sewer (if not impacted above DEQ surface water 19 EMP Version 2, January 2021 standards). Alternatively, additional groundwater sampling may be conducted under a DEQ- approved work plan in the areas of caisson installations to evaluate contaminant concentrations for potential discharge to storm sewer. Local officials will be contacted for approval prior to discharge of groundwater to the storm sewer. 5) Are monitoring wells currently present on the Brownfields Property?.................❑Yes ®No If yes, are any monitoring wells routinely monitored through DEQ or other agencies?.................................................................................................................. ❑Yes ❑ No 6) Please check methods to be utilized in the management of known and previously unidentified wells. ® Abandonment of site monitoring wells in accordance with all applicable regulations. It is the Brownfields Program's intent to allow proper abandonment of well(s) as specified in the Brownfields Agreement, except if required for active monitoring through another section of DEQ or the EPA. ❑ Location of existing monitoring wells marked ❑ Existing monitoring wells protected from disturbance ❑ Newly identified monitoring wells will be marked and protected from further disturbance until notification to DEQ Brownfields can be made and approval for abandonment is given. 7) Please provide additional details as needed: Click or tap here to enter text. Please note, disturbance of existing site monitoring wells without approval by DEQ is not permissible. If monitoring wells are damaged and/or destroyed, DEQ may require that the PD be responsible for replacement of the well. PART 3. SURFACE WATER 1) Is surface water present at the property? ❑ Yes ® No ❑ Unknown 2) Attach a map showing the location of surface water at the Brownfields Property. 3) Is surface water at the property known to be contaminated? ❑ Yes ® No 4) Will workers or the public be in contact with surface water during planned redevelopment activities? ❑ Yes ® No 5) In the event that contaminated surface water is encountered during redevelopment activities, or clean surface water enters open excavations, list activities for management of such events (e.g. flooding, contaminated surface water run-off, stormwater impacts): If surface water run-off gathers in an open excavation within an area determined to be impacted during construction activities, appropriate worker safety measures will be undertaken. The accumulated water will be allowed to evaporate/infiltrate to the extent time for dissipation does 20 EMP Version 2, January 2021 not disrupt the construction schedule. Should the time be needed for natural dissipation of accumulated water be deemed inadequate, the water will be tested and disposed off -site (if impacted), or tested and discharged to the storm sewer (if not impacted above DEQ surface water standards) in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. PART 4. SEDIMENT 1) Are sediment sources present on the property? ❑ Yes ® No 2) If yes, is sediment at the property known to be contaminated: ❑ Yes ❑ No ❑ Unknown 3) Will workers or the public be in contact with sediment during planned redevelopment activities? ❑ Yes ® No 4) Attach a map showing location of known contaminated sediment at theproperty. S) In the event that contaminated sediment is encountered during redevelopment activities, list activities for management of such events (stream bed disturbance): Not applicable. PART 5. SOIL VAPOR 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the following vapor intrusion screening levels (current version) in the following media: IHSB Residential Screening Levels: Soil Vapor:...........® Yes ❑ No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown IHSB Industrial/Commercial Screening Levels: Soil Vapor:...........© Yes ❑ No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown 2) Attach a map showing the locations of soil vapor contaminants that exceed site screening levels. 3) If applicable, at what depth(s) is soil vapor known to be contaminated? 8 ft bgs 4) Will workers encounter contaminated soil vapor during planned redevelopment activities? ❑ Yes ❑ No ❑x Unknown In the event that contaminated soil vapor is encountered during 21 EMP Version 2, January 2021 redevelopment activities (trenches, manways, basements or other subsurface work,) list activities for management of such contact: In the unlikely event impacted soil vapors are encountered during future redevelopment activities, worker breathing zone will be monitored using a calibrated PID. If results indicate further action is warranted, appropriate engineering controls (such as use of industrial fans) will be implemented. PART 6. SUB -SLAB SOIL VAPOR 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the following vapor intrusion screening levels (current version) in sub -slab soil vapor: IHSB Residential Screening Levels: Soil Vapor:...........© Yes ❑ No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown IHSB Industrial/Commercial Screening Levels: Soil Vapor: ........... ❑ Yes ® No ❑ Unknown 2) Groundwater:..... ❑ Yes ❑x No ❑ Unknown If data indicate that sub -slab soil vapor concentrations exceed screening levels, attach a map showing the location of these exceedances. 3) At what depth(s) is sub -slab soil vapor known to be contaminated? ®0-6 inches ❑Other, please describe: Click or tap here to enter text. 4) Will workers encounter contaminated sub -slab soil vapor during planned redevelopment activities? ❑ Yes ❑ No ❑X Unknown ❑ If no, include rationale here: l.u(.K ur LdP nere w enter tex" 5) In the event that contaminated soil vapor is encountered during redevelopment activities, list activities for management of such contact In the unlikely event impacted soil vapors are encountered during future redevelopment activities, worker breathing zone will be monitored using a calibrated PID. If results indicate further action is warranted, appropriate engineering controls (such as use of industrial fans) will be implemented. PART 7. INDOOR AIR 1) Are indoor air data available for the Brownfields Property? ❑ Yes ® No ❑ Unknown 2) Attach a map showing the location(s) where indoor air contaminants exceed site screening levels. 22 EMP Version 2, January 2021 3) If the structures where indoor air has been documented to exceed risk -based screening levels will not be demolished as part of redevelopment activities, will workers encounter contaminated indoor air during planned redevelopment activities? ❑ Yes ❑ No ❑ Unknown ❑ If no, include rationale here: Click or tan hares to antar tin, 4) In the event that contaminated indoor air is encountered during redevelopment activities, list activities for management of such contact: In the unlikely event there is evidence of potential indoor air issues (i.e., unusual odors) during future redevelopment activities, the area will be evacuated and appropriate safety screening of the indoor air will be performed. If warranted, safety screening procedures will include periodically screening indoor air for volatile organic vapors with a calibrated photoionization detector and calibrated methane gas detector. If results indicate further action is warranted, appropriate engineering controls (such as use of industrial fans) will be implemented. VAPOR INTRUSION MITIGATION SYSTEM Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property? ❑ Yes ® No ❑ Unknown ® If no or unknown, include rationale here as well as plans for pre -occupancy sampling, as necessary: Based on results of vapor intrusion assessment activities documented in H&H's October 2020 Brownfields Assessment Report, there does not appear to be an unacceptable vapor intrusion risk to future non-residential building occupants. In an email dated December 30, 2020, the DEQ Brownfields Program provided concurrence with these findings and stated that a vapor intrusion mitigation system is not required for the proposed Site building and that additional vapor intrusion assessment will not be required post -construction. If yes, ❑ VIMS Plan Attached or ❑ VIMS Plan to be submitted separately If submitted separately provide date: uncK or tap here to enter tex VIMS Plan shall be signed and sealed by a NC Professional Engineer If no, please provide a brief rationale as to why no vapor mitigation plan is warranted: Note that approval of this EMP does not imply approval with any vapor intrusion mitigation land use restrictions or requirements of the recorded or draft Brownfields Agreement and that 23 EMP Version 2, January 2021 separate approval of mitigation measures will be required. CONTINGENCY PLAN — encountering unknown tanks, drums, or other waste materials In this section please provide actions that will be taken to identify or manage unknown potential new sources of contamination. During redevelopment activities, it is not uncommon that unknown tanks, drums, fuel lines, landfills, orother waste materials are encountered. Notification to DEQ Brownfields Project Manager, UST Section, Fire Department, and/or other officials, as necessary and appropriate, is required when new potential source(s) of contamination are discovered. These Notification Requirements were outlined on Page 1 of this EMP. Should potentially impacted materials be identified that are inconsistent with known site impacts, the DEQ Brownfields Project Manager will be notified and a sampling plan will be prepared based on the EMP requirements and site -specific factors. Samples will generally be collected to document the location of the potential impacts. Check the following chemical analysis that are to be conducted on newly identified releases: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver) EPA Method 6020 and EPA Method 7471 ❑ Pesticides: Specify Analytical Method Number(s): UICK or tap nere to enter text ❑ PCBs: Specify Analytical Method Number(s): 1, or tap h--- ---.--- ._ --.. ❑ Other Constituents & Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.) Please note, if field observations indicate the need for additional analyses, they should be conducted, even if not listed here. Hexavalent chromium by EPA Method 7199 Please provide details on the proposed methods of managing the following commonly encountered issues during redevelopment of Brownfields Properties. During construction activities, contractors may encounter unknown sub -surface environmental conditions (i.e., tanks, drums, or waste materials) that if encountered, will require proper management. Prior to beginning Site work, H&H will attend a pre -construction meeting with the PD and the redevelopment contractors to discuss the DEQ approved EMP and various scenarios when it would be appropriate and necessary to notify H&H of the discovery of unknown subsurface features or potentially impacted media at the Site. In the event that such conditions are encountered during Site development activities, the environmental actions noted below will be used to direct environmental actions to be taken during 24 EMP Version 2, January 2021 these activities and sampling data for potentially impacted soil and the disposition of impacted soil will be provided to DEQ when the data becomes available. Underground Storage Tanks: In the event a UST or impacts associated with a UST release are discovered at the Site during redevelopment activities, the work in this location will halt and the on -call environmental professional will be consulted. The UST and/or UST related impacts will be addressed through the Brownfields Program in accordance with the DEQ UST Section Guidance: Guidelines for Site Checks, Tank Closure and Initial Response and Abatement, May 17, 2021 version (UST Guidance) except that the collection of MADEP samples will not be necessary. If a UST is encountered, the UST will be removed and transported off -Site for disposal at a suitable facility. If the UST contains residual fluids, the fluids will be sampled for VOCs, SVOCs, and RCRA metals, and transported off -Site for disposal at a suitable facility based on the laboratory analytical results prior to removing the UST from the ground. If a UST is encountered that cannot be removed or does not require removal for geotechnical or construction purposes, with DEQ prior approval it will be abandoned in -place and construction will proceed. Impacted soil in the vicinity of the UST will be managed in accordance with the Managing On -Site Soil section outlined above in the EMP. Impacted soil will be removed and confirmation samples will be collected from the base and sidewalls of the UST excavation, and along any product lines at a rate of 1 sample for every 10 feet of line. The analytical program will consist of EPA Methods 8260, 8270, and RCRA metals. Sub -Grade Feature/Pit: If a sub -grade feature or pit is encountered and does not require removal for geotechnical or construction purposes, the contractor will be instructed to stop work and contact the on -call environmental professional to evaluate the feature and the Brownfields Program notified within 48 hours of discovery. The contents and the feature will be removed and transported off -Site for disposal. If conditions indicate that the feature cannot be removed due to a structural integrity issue, the Brownfields Program will be consulted and the area around the feature assessed for impacts including confirmatory soil and/or groundwater sampling. Impacted soils will be managed in accordance with Part LA and/or Part 1.0 of this EMP. The feature will be filled with soil or suitable fill and construction will proceed. Where appropriate, the bottom may be penetrated before backfilling to prevent fluid accumulation. If the pit has waste in it, the waste will be set aside in a secure area and will be sampled for waste disposal purposes for TCLP VOCs, TCLP SVOCs, TCLP metals, and TCLP hexavalent chromium and disposed off -site at a permitted facility or the waste will be managed in accordance with the Managing On -Site Soil section outlined above in the EMP, whichever is most applicable based on the type of waste present. If the pit must be removed and the observed waste characteristics indicate the concrete may potentially be contaminated, the concrete will be sampled and analyzed by methods specified by the disposal facility. Buried Waste Material — Note that if buried waste, non-native fill, or any obviously filled materials 25 EMP Version 2, January 2021 is encountered, the DEQ Brownfields Program must be notified to determine if investigation of landfill gases is required: If excavation into buried wastes or impacted soils occurs, the contractor will be instructed to stop work in that location and notify the environmental consultant. The Brownfields Program will be notified within 48 hours of the discovery of buried waste material. The environmental consultant will review the materials and the waste will be removed, characterized, and disposed of off -site. Confirmation sampling will be conducted at representative locations in the base and the sidewalls of the excavation after the waste or impacted soil is removed. The confirmation samples will be analyzed for VOCs, SVOCs, RCRA metals, and hexavalent chromium. Areas of soil impacts above DEQ IHSB Industrial/Commercial PSRGs that remain in place after excavation is complete will be managed pursuant to this EMP. The Brownfields Program will be contacted to determine if investigation of landfill gases is potentially warranted. Re -Use of Impacted Soils On -Site: Please refer to description outlined in the Managing On -Site Soil section of the EMP above. If unknown, impacted soil is identified on -site, management on -site can be considered after the project team provides the necessary information, outlined in Part I.A. Item 11, for Brownfields Project Manager approval prior to final placement on -site. If other potential contingency plans are pertinent, please provide other details or scenarios as needed below: Click or tap here to enter text. POST -REDEVELOPMENT REPORTING ® Check this box to acknowledge that a Redevelopment Summary Report will be required for the project (as part of the Brownfields Agreement Land Use Restriction No. 12.e.) within 90 days after each one-year anniversary of the effective date of the Brownfields Agreement, which is September 9, 2021. If the project duration is longer than one year, an annual update is required and will be due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of this EMP (as agreed upon with the Project Manager). These reports will be required for as long as physical redevelopment of the Brownfields Property continues, except that the final Redevelopment Summary Report will be submitted within 90 days after completion of redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary Report is anticipated to be submitted on 12/8/2022 The Redevelopment Summary Report shall include environment -related activities since the last report, with a summary and drawings, that describes: 1. actions taken on the Brownfields Property; 2. soil grading and cut and fill actions; 26 EMP Version 2, January 2021 3. methodology(ies) employed for field screening, sampling and laboratory analysis of environmental media; 4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and ultimate disposition of any soil, groundwater or other materials suspected or confirmed to be contaminated with regulated substances; and 5. removal of any contaminated soil, water or other contaminated materials (for example, concrete, demolition debris) from the Brownfields Property (copies of all legally required manifests shall be included). ❑X Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment Summary Report in compliance with the site's Brownfields Agreement. 27 EMP Version 2, January 2021 APPROVAL SIGNATURES Brownfields Project Number: 24030-20-092 Brownfields Project Name: General Baptist State Convention Property 12/6/2021 Prospective Developer: Narsi Development Raleigh, LLC Date Click or tap to enter a date. Printed Name/Title/Company: Mr. Deven Patel / Principal / Narsi Properties 12/2/2021 Consultar,,.: Hart & Hickman, PC Date Click or tap to enter a date. Printed Name/Title/Company: Mr. Justin Ballard, P.G. / Project Manager / Hart & Hickman, PC - - ---- ---- -- -M.- r Brownfields Project Manager: Ms. Sharon Eckard 28 EMP Version 2, January 2021 12/2/2021 Date Click or tap to enter a date. Figure I NCBP Diagram for Temporary Containment of Impacted or Potentially Impacted Soil Cross -Section View Top Plastic Cover Sheeting: Underliner: 1 layer, minimum of 10 (1 Layer, minimum: 10 mil thick) mil thick plastic Berm (Straw bales, Weight composted earth, etc.) (If plastic cover used) Land Contaminated Soils Surface \ z — Straw Bale Berm Map View *E:1 ■ Weight . . ....... .......................................O^ ■� Contaminated Soils ' 00■ O // \o Plastic Sheeting Note: Adapted from NC DEQ UST Section "Guidelines for Ex Situ Petroleum Contaminated Soil Remediation" dated December, 1, 2013 29 EMP Version 2, January 2021 _ IAPPROXIMATE TITLE 0 2000 4000 SITE LOCATION MAP PROJECT GENERAL BAPTIST STATE CONVENTION PROPERTY SCALE IN FEET 603 S. WILMINGTION STREET 112 & 114 E. LENOIR STREET RALEIGH, NORTH CAROLINA U.S.G.S. QUADRANGLE MAP 3921 Sunset Ridge Road, Ste.301 hart hickman Raleigh,North Carolina 27607 919-847-4241 (p) 919-847-4261 (0 RALEIGH WEST, NORTH CAROLINA 2002 SMARTER ENVIRONMENTAL SOLUTIONS License#C-1269/#C-245Geology QUADRANGLE DATE: 10-05-2020 REVISION NO: 0 7.5 MINUTE SERIES (TOPOGRAPHIC) JOB NO: NAP-001 FIGURE NO: 1 lop ir 1 CHARTER SQUARE 4 i . � r PARKING LOT (529 S. WILMINGTON STREET) I _ FORMER MOTOR FREIGHT STATION J Lou EAST LENOIR STREET •� PIN:1703763353 PIN:1703764322 r 1 l 1 1 i .4 A PIN: 1703764352 FORMER PETROLEUM STATION w � AND AUTO REPAIR SHOP a it Au it� FORMER AUTOMOTIVE f' REPAIR SHOP !4J I r co oj l-A �J \h\\\\\� �-FORMER 0EERLESS MASTER CLEANERS O ) • PROPOSED C '• AND DRYERS / CIVIC CENTER LOTS ELEVATOR (10. W. SOUTH STREET) Z co PARKING LOT J 01 . AA (0 FAYETTEVILLE STREET) m BOILER ROOM so' � i . 7t` ti (BASEMENT LEVEL) - Ar • • -• • I SHAW UNIVERSITY v �% • , 0ti (125 E. SOUTH STREET) lv x MCDONALD'S . � I FORMER PETROLEUM (105 E. SOUTH STREET) ,y STATION AS , � T..-� ♦ *. r , `•. ' r� .r ♦ � w EAST SOUTH STREET All �n DUKE ENERGY CENTER FOR •I SHAW UNIVERSITY r THE PERFORMING ARTS (118 E. SOUTH STREET) (2 E. SOUTH STREET) I ' ., 7 Table 1 Summary of Soil Analytical Data General Baptist State Convention Property Raleigh, North Carolina Brownfields Project No. 24030-20-092 H&H Job No. NAP-001 SB-2 Sample ID SB-1 BG-1 SB-2 I DUP-SB Industrial/ Commercial Regional Background Metals in Soil(2) Depth (ft bgs) 1-2 1-2 1-2 Sample Date 8/25/2020 8/25/2020 8/25/2020 PSRGs(1) 603 S. Wilmington Background Location 112/114 E. Lenoir Street Range Mean Street Location VOCs (8260D) (mq/kq) T Acetone 0.109 0.0558 0.0303 10.576 140,000 -- -- SVOCs (8270E) (mq/kq) -- -- RCRA Metals (602013/7471 B) (mq/kq) 2.19 2.57 2.41 7.61 3.0 1.0-18 4.8 Arsenic Barium 48.2 405 375 67.5 47,000 50-1000 356 Cadmium <0.286 0.545 0.444 <0.312 200 1.0 - 10* 4.3' Chromium (total) 12.3 16.7 16.3 43.2 NE 7.0 - 300 65 Lead 246 258 247 25.3 800 ND - 50 16 Selenium 0.485 0.737 0.695 0.690 1,200 <0.1 -0.8 0.42 Silver 0.0298 0.718 0.615 0.0568 1,200 NE NE Mercury 0.131 2.48 2.46 0.567 9.7 0.03 - 0.52 0.121 Notes: 1) North Carolina Department of Environmental Quality (DEQ) Preliminary Soil Remediation Goals (PSRGs) (July 2020). 2) Range and mean values of background metals for North Carolina soils (* = southeastern US soils) taken from Elements in North American Soils by Dragun and Chekiri, 2005. Only analytes with concentrations above the laboratory method detection limit are shown, with the exception of RCRA metals. Laboratory analytical methods are shown in parentheses. All concentrations are reported in milligrams per kilogram (mg/kg). VOCs = volatile organic compounds; SVOCs = semi -volatile organic compounds; RCRA = Resource Conservation and Recovery Act; ft bgs = feet below the ground surface; NE = not established; -- = not applicable. Table 1 (Page 1 of 1) SMAA-Master Projects\Narsi Properties (NAP)\S. Wilmington Street Hotel (NAP.001)\EMP\Data Tables 2/8/2021 Hart & Hickman, PC Table 2 Summary of Groundwater Analytical Data General Baptist State Convention Property Raleigh, North Carolina Brownfields Project No. 24030-20-092 H&H Job No. NAP-001 TMW-1 Sample ID TMW-2 TMW-1 I DUP-GW N Well Screen Depth (ft bgs) 25-35 23-33 ater Groundwater Sample Date 8/25/2020 8/25/2020 Standard(') 112/114 E. Lenoir Location 603 S. Wilmington Street Street VOCs (820613) (ug/L) Acetone <7.00 <7.00 8.61 J 6,000 Toluene 0.59 J <0.50 <0.50 600 SVOCs (8270E) (ug/L) Below l\AAthnrl Detection Lir -- RCRA Metals (6020B/7470A) (pq/L) 0.94 J 0.58 J 10 Arsenic Barium 133 112 87.7 700 Cadmium 0.222 J 0.164 J 0.294 J 2 Chromium, total 3.44 2.39 1.70 10 Lead 22.0 12.0 1.52 15 Selenium 11.5 10.4 2.53 20 Silver <0.06 <0.06 <0.06 20 Mercury 1<0.20 1 <0.20 1 <0.20 1 1 Notes: 1) North Carolina Department of Environmental Quality (DEQ) 15A NCAC 02L.0202 Groundwater Standards (NC 2L Standards) (April 2013). Only compounds detected in at least one sample are shown, with the exception of RCRA metals. Concentrations are reported in micrograms per liter (pg/L). Laboratory analytical method is shown in parentheses. Bold values indicate compounds detected above NC 2L Standards. J = Estimated value that is less than the laboratory reporting limit and greater than or equal to the method detection limit. ft bgs= feet below ground surface; VOCs = volatile organic compounds; SVOCs = semi -volatile organic compounds; RCRA = Resource Conservation and Recovery Act; NE = not established.; -- = not applicable. Table 2 (Page 1 of 1) SAAAA-Master Projects\Narsi Properties (NAP)\S. Wilmington Street Hotel (NAP.001)\EMP\Data Tables 2/8/2021 Hart & Hickman, PC Table 3 Summary of Vapor Intrusion Analytical Data General Baptist State Convention Property Raleigh, North Carolina Brownfields Project No. 24030-20-092 H&H Job No. NAP-001 SGP-1 Sample ID SSGP-1 SSGP-2 SGP-2 SGP-3 SGP-1 I DUP-SGP Non -Residential SGSL(1) Sample Date 8/26/2020 8/26/2020 8/26/2020 8/26/2020 8/26/2020 Location 603 S. Wilmington Street 112/114 E. Lenoir Street VOCs (TO-15) (ug/m3) Acetone 6.45 7.32 205 193 26.2 34.6 2,700,000 2-Butanone (MEK) 2.84 3.35 156 148 8.90 16.5 440,000 Benzene <2.60 <2.72 37.7 34.8 6.31 11.9 160 Benzyl Chloride <4.21 <4.40 <4.47 31.3 <4.47 <4.40 25 1,3-Butadiene <1.80 <1.88 <1.91 <1.85 5.93 10.9 41 Carbon Disulfide <2.53 <2.65 4.00 3.84 <2.69 7.48 61,000 Cyclohexane 3.21 J 3.71 6.93 8.91 10.8 13.1 530,000 Ethanol 97.2 52.4 25.9 32.0 16.2 18.2 NE Ethyl Acetate <2.93 <3.06 30.6 29.9 <3.11 5.00 6,100 Ethylbenzene 243 292 525 491 320 507 490 4-Ethyltoluene <4.00 <4.18 226 200 8.84 33.5 NE Heptane <3.33 <3.48 49.1 45.4 17.8 29.0 35,000 Hexane <2.86 <3.00 8.04 7.38 10.0 22.0 61,000 Isopropanol 12.7 7.61 11.3 10.0 4.13 3.65 18,000 Methylene Chloride <2.82 <2.95 5.87 5.53 3.12 J <2.95 53,000 4-Methyl-2-pentanone (MIBK) <3.33 <3.48 256 236 11.4 13.9 260,000 Naphthalene <4.26 <4.46 7.30 5.88 <4.52 5.24 J 36 Propylene <1.40 <1.46 11.7 10.3 72.9 169 260,000 Styrene <3.46 <3.62 45.3 43.3 13.5 24.4 88,000 Tetrachloroethylene 7.32 14.4 120 115 90.8 31.8 3,500 Tetrahydrofuran 5.43 5.56 64.9 62.0 6.21 10.5 180,000 Toluene <3.06 <3.20 814 751 57.3 153 440,000 Trichloroethylene <4.37 <4.57 12.4 11.2 <4.64 <4.57 180 1,1,1-Trichloroethane <4.43 <4.64 18.7 17.4 <4.71 <4.64 440,000 Trichlorofluoromethane (Freon 11) <4.57 <4.78 5.15 J 5.12 J <4.85 <4.78 NE 1,2,4-Trimethyl benzene 4.50 J 4.40 J 822 765 25.8 114 5,300 1,3,5-Trimethyl benzene <4.00 <4.18 316 297 9.61 42.5 5,300 Xylenes, total 1,327 1,564 2,841 2,640 1,724 2,702 8,800 Risk Evaluation (Soil Gas to Indoor Air)(2) 5.0E-07 6.0E-07 1.6E-06 2.7E-06 8.6E-07 1.5E-06 1.0E-04 Non -Residential Carcinogenic Risk Non -Residential Hazard Index 3.2E-02 3.7E-02 1.4E-01 2.0E-01 5.4E-02 8.9E-02 1.0E+00 Notes: 1) North Carolina Department of Environmental Quality (DEQ) Sub -slab and Exterior Soil Gas Screening Levels (SGSLs) (July 2020) 2) Risk evaluation performed using the July 2020 DEQ Risk Calculator for the soil gas to indoor air vapor intrusion pathway. Only VOCs detected in at least one sample are shown. Concentrations are reported in microqrams per cubic meter (uq/m3). Laboratory analytical method is shown in parentheses. Underlined values indicate compounds detected above Non -Residential SGSLs. J = Estimated value that is less than the laboratory reporting limit and greater than or equal to the method detection limit. VOCs = volatile organic compounds; NE = not established. Table 3 (Page 1 of1) SAAAAMaster Projects\Narsi Properties (NAP)\S. Wilmington Street Hotel (NAP.001)\EMP\Data Tables 1l- Hart &Hickman, 1. Appendix A Redevelopment Plan hart ` hickman SMARTER ENVIRONMENTAL SOLUTIONS 1 2 2.3 4 5 6 7 8 10 11 15'-3 1 /4" 9'-0 3/4" 3 15'-11 1 /2" 25'-0 1 /4" 25'-0 1 /4" 25-0 1 /4'' 25-0 1 /4" 25-01 /4" 13'-11 1 /4" 14'-0" I I I I I I I I I I 4.1 4.6 5.2 I I I I I I I I I I 12'-7 3/8" 10'-4 7/8" 5-8 3/8" 2-0' I I I I I I I I I I I I I I I I I I I I I 3 DS36 DS48 DS48 S202 DS4�=+313'-6" DS48 DS48 T/DS=+314'-6"DS36 DS36 I I T/DS=+314'-6" I T/DS=+314'-6" I T/DSI T/DS=+312'-6" T/DS=+312'-6" T/DS=+312'-0" T/DS=+312'-0" B/DS =+282'-0" B/DS=+281'-0" - B/DS =+279'-0" B/DS =+277'-0" B/DS =+275'-0" B/DS =+273'-0" --B/DS =+269'-0" B/DS=+266'-0" I ift 4 - - - --- - - 'I - - -�--- - - - -- -- - - --- - - - - - - - -- - DS36 - - - - - - --- GRADE BEAM co 5200 10' 7 3/4" T-10 3/4" ELEV CHANGE T/DS=+311'-6" EXTERIOR STAIR, SEE 9/S200 C G a. _ 9 DS36 _ + _ B DS 272' 0" GB1 24x24 / [ 314' 10"] GB1 24x24 +313'-6" � GBl 24x24/ +313' 6" � / = 5203 = T/DS +312' 10" o I Q I II o B/DS=+280'0" _.f----------------------------------- ` J ---------------------` 1------------------------ ---- z DS3 DS36 RAM DS48 DS36 i DS36 a DS36 DS42 — T DS F+311'-6" T/DS=+311'-6" 1 T/DS=+314'-6" T/DS=+314'-6" Q / T/DS=+312'-0" T/DS=+312'-0" I T/DS=+308'-10" B/DS =+286' 0" B/DS =+283'-0" - - - - - - N v - - - - - - - - - - - - - - - - M lil� - - i - - - - - - - - B/DS +277'-0" B/DS +275'-0" B/DS +267'-0" /DS +265'-0" B/DS +263'-0" 4 DS36 °° + cD U P ' 5202 T/DS =+312' 4" li RAMP I\ 1 2'-3" B/DS =+282'-0" GB4 24x30 / [ 314'-10"] ' DS36 4"SLAB ON GRADE Q No x li DS36 +314'-10' ] T/DS=+312'-4" GB4 24x30 I [ a 5" EXTERIOR SLAB 1 T/DS =+312' 4", �b TYP SEE 1/5200 °N° li [SLAB " EXTERIOR ON GRADE v -r------------! ---- --- B/ S=+280'-0' �\ SEE 7/5200 9 a SEE 2/5200 B/DS=+284'-0" --------------------- - =, 55�'+� 5\mob �b TOC = +315' 6" III a ON GRADE M D S2 1 - -- - r -- T 5+ \ SEE 2/5200 + M- - - - - - - - - -4- +� a oB.3 M Mv o ¢ = X DS36 v T/DS =+31 V-6" NLL o B.4 9 �' -', t�+ F / [+314'-6"] `" F5 / [+314'-6"] F5/ [+314'-6"I I I F5/ [+314'-6"] M I m a co S202 SS - - - - - - J ,,, I B/DS =+269'- c9 w U L_ -J U +i SOU 6.5 v LD � ---- I I w SLAB LEAVE TJT --- v i w DS36 DS54 �� " --- ' - - - o I DS42 DS36 o DS -+31 T/DS=+314'-6 _ _ _ _ 1'-0" 4'-8 1 /2" 5'-10" 9'-9 1 /2" 9'-101 /4" I 1'-0"/-L , _+ + „ O 0 1 1 -•—• • •-• . 1 1 •--• • —• • •—•—• • •--• • • ,• • •--• • -•—• • - • • ;• `�i-i, ��� �i�i, ��i�, ��i�i�i�� ��i��i�i�i,��i�i,���i��i�i� �MTD=09O �i� 1 ' 1 1 ' 1 1 ■ ■ 1 1 11 ■1: 1 1 e.1 1 1 I 1 1 1 1 1• 1 ■ ■■1 �_•�I��I��I�1��•1�� �I�I�II�I�I�I�I��1 1 1Lommi -.-._ ._._._._._ y c DS36 m ' � S56XbX b I B/DS =+282'-0" T/DS=+309'-0" /DS=+309'-0' $201 - DS42 - 5201 r �_-_� L T/DS=+312'-10"0 /�- OC-31T3" o`0 ,-, B/DS=+281'-0' B/DS=+280'-0' T /DS=+309'-0" �I IL---- B/DS=+285'-0" - = CSWI .- B/DS =+279'-0" 3 i ;L=-- --- I v o I I I I UI S DIVI ER BEA \ i IDS36 F --- --- I X = 1 81/2" I RAMP 113' 11 1/2" 1'-0" 9'-6" 1'-0" SEE6/5200 8 HSS8x4xl/4 Ir T/DS=+309'-0„ I --- --- 5203 DOWN 91/2" o 5203 i B/DS=+271'-0" --- --- --- ---- ---------- 1 I = I _ _ - M N o i SEEI U /5201, TYP 4 CORNERS H v y I v /�- SEE 4/S201, TYP 4 CORNERS i I SEE 3/5201 -, T/DS=+308'-10" S202 GB1 24x24 / [+315'-2"] \`GB1 24x24 / [+315'-2 1 /� CSW7 1 - i i B/DS=+259'-0" DS36 h' - — — — — — — — T/DS=+312'-16"1 a I — — DS54 — L� — 1 -315' ------- --- — --------------- — — — -- -- — — — - DS60 B/DS=+285'-0" i-1 N �/ DS48 DS36--' CSW2 DS5d�_ D42 DS36 DS54 DS36 DS36 _%DS4 T/DS=+309'-0" - B/DS =+284'-0" T/DS=+309'-0" T/DS=+309'-0" T/DS=+309'-0" T/DS=+313'-2" T/DS=+313'-2" DS T/DS=+309'-0" T/DS=+309'-0"i- - DS66 B/DS =+263'-0" B/DS=+261'-0" 3 O I B/DS =+282'-0" B/DS=+281'-0" B/DS=+280'-0" T/DS =+3 9' 0" + B/DS=+278'-0" B/DS =+276'-0" T/DS =+3 19'-0" B/DS=+271'-0" B/DS =+269'-0" T/DS=+309'-0" 4'-10 5/16' S203 I B/DS =+2 9'-0" �i B/DS =+273'-0" B/DS =+267'-0" M W l Ox22 I I GRADE BEAM 9" 9' 9" X 9' 9" N 1 RAMP RAMP l I I M fry■► e9i�����i������i�ial■�1[1..a �= 1 11 �wwww�wwwwn� 1 II .• I I■ .w IiMWW ■■■■ www.rl1 �mmmmmmmii :e■ ENIE ■�iei�slarii� 1 �� WL'GLS�■�I■■li /I IN PROPERTY REDUCE GRADE — LINE BEAM WIDTH TO 18 1 /2" AT VAULT DS36, I GB124x24 DS48 T/DS=+313'-4" [315'-4"] T/DS -+31 V-6" B/DS =+286'-0" B/DS=+285'-0" 1 I 1 T 3" 11 CANT I I 1 I I 2'-7" 12'-8 1 /4" I I bb 2 GB4 24x30/ [+314'-0"] GRADEBEAM 5 ELEV CHANGE G9 7 25-0 1 /4' ml LL cy DS36 1 T/DS=+313'-2" Z N B/DS =+279'-0" MILij _ NI - xl 7- TOC B4 24 30 5" SLAB ON GRADE SEE 1/S200 o_ U OFFSET 48" DRILLED SHAFTS 4" OFF GRID F , rrl1� i � - - - r------------------------- DS48 GB4 24x30/ [+314'-0"] DS48 T/DS =+31 V-6" T/DS =+309' 0" B/DS =+283'-0" B/DS =+280' " I I I I 25-0 1 /4" I I 3 4 ---------------- -� DS36 T/DS=+312'-8" B/DS =+279'-0" 7-10 1 /2" 16-9" CL GB AND DRILLED SHAFT BEGIN 8" CI WALL AT FACE OF COL GB4 24x30 / [+312'-4"] GRADE BEAM ELEV CHANGE 0' 4' 8' 16' 32' 25-0 114" UP -- UP I d x N I 5" EXTERIOR SLAB ON GRADE CJ, TYP - a - - I SEE 2/5200 - - - I - - - - - - - - - - \ -- DS36 T/DS=+308'-10" B/DS =+258'-0" I I I I II li \ t\ GB3 24x30 / [+315'-2"] GB3 24x30 / [+315'-2"] ------------ DS36 ------------, `�' 6 c9 I IT/DS=+312'-8" B/DS=+26T-0"I i li A m 5203 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DS36 DS36 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T/DS=+312'-8" T/DS =+ 12'-8" CI B/DS =+276'-0" 8 B/DS = 272'-0" "' II i I STORM FILTER i VAULT, SEE DS36 (I III T/DS=+308'-10'ry it 5203 + 4 Z I i CIVIL DWG B/DS =+258'-0" d 5203 v X I1 I I I i TOC=317'.4" U I U p o ao TOC = +316'-0" •; c91i I I I------------- OFFSET 48" li N 1'-5 1 /2 DRILLED SHAFTS `r 4' OFF GRID F - ----------------- --------------------- ------ --�----�---------------- -- - '—�-------- °I ----- --------- -I. r-------------- , DS36 DS48 GB4 24 30 +314' 4" DS48 GB4 24 30 +312' 4" DS48 GB4 24 30 / +311' 4" DS48 GB4 2430 DS36 GB4 24 30 G 0 -0 x [ ] _ x /[ 1 x /[ ] x N T/DS=+309'-10" T/DS=+309'-10" T/DS=+308'-10" T DS=+308'-10"[31 V-4"1 + / T/DS=+308'-10" / 131 l'-4"] T/DS=+308'-10" o B/DS =+276'-0" 6 B/DS =+272'-0" B/DS =+267 -0" GRADE BEAM 7 B/DS =+263'-0' B/DS=+260'-0" = w I 5202 I ELEV CHANGE S202 I I I B/DS =+258'-0" PROPERTY LINE I I I I I I 25-0 1 /4'' 25-0 1 /4" 25-01 /4" 13'-11 1 /4" 14'-0" 1 _p EOS I I I I I I 5 6 b 8 10 11 DUDA I PAINE ARCH I T E C T S OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda i Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER / LANDSCAPE McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 FIRM LICENSE: #P-1591 = maw T. 10/09/2020 THIS DOCUMENT WAS ELECTRONICALLY SIGNED BY ROBERT T MACIA n4), W � � O � N O �U Z 0 C`7 ry O 1-O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other Than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION FOOTING SCHEDULE PLAN NO ES: LEGEND: REINFORCEMENT 1. SEE S 01 FOR GENERAL STRUCTURAL NOTES AND ABBREVIATION LEGEND. XXX'-XX" CJ FOOTING DIMENSIONS (EACH WAY) 2. REF ENCE ELEVATION (0'-0") IS ACTUAL ELEVATION 312'-0". TOP OF SLAB ELEVATION SLAB CONTROL JOINT MARK WIDTH LENGTH THICKNESS TOP BOTTOM ISSUE DATE: 10 01 2 3. DS NIDCATES DRILLED SHAFT TYPE. SEE 7/S201 FOR DRILLED SHAFT SCHEDULE AND CONSTRUCTION DETAILS. F5 5'-0" 5'-0" 1'-01, PROJECT NUMBER: 21 T/DS INDICATES TOP OF DRILLED SHAFT ELEVATION. SLOPED SLAB SURFACE X X B/DS INDICATES ASSUMED BOTTOM OF DRILLED SHAFT ELEVATION. 4. DRILLED SHAFTS ARE TO BE CENTERED ON WALLS AND COLUMNS UNLESS NOTED OTHERWISE. X X GROUND 5. GB# / [xxx'-xx] INDICATES GRADE BEAM TYPE AND TOP OF GRADE BEAM ELEVATION. SEE S202 FOR GRADE BEAM i?TTTT -------- CONSTRUCTION DETAILS. SLOPED SLAB SURFACE i STEP IN TOP OF GRADE BEAM ELEVATION. 6. F# INDICATES SPREAD FOOTING. SEE SCHEDULE THIS SHEET. i -� . SEE DETAIL 2/S202 LEVEL 7. Gl INDICATES 4" STEEL BAR GRATING. 8. [xxx'xx"] INDICATES TOP OF FOOTING ELEVATION. STEP IN SLAB ELEVATION 9. THICKEND SLAB UNDER INTERIOR CMU WALLS ARE INDICATED. DETERMINE DIMENSIONS AND EXACT EXTENT OF ALL THICKENED SHADED AREA: 5" EXTERIOR SLAB ON GRADE RAMP SLAB FOR CMU PARTITIONS FROM THE ARCHITECTURAL DRAWINGS. FOUNDATION 10. DETERMINE LOCATIONS OF ALL FLOOR DRAINS, SLOPES TO DRAINS, AND SLAB DEPRESSIONS FROM ARCHITECTURAL DRAWINGS. 11. SEE S200, S201 AND S202 FOR MISCELLANEOUS TYPICAL FOUNDATION DETAILS. HATCHED AREA: RAISED CONCRETE ISLAND 12. SEE S500 AND S501 FOR COLUMN SCHEDULE. PLAN CD CV CV GROUND LEVEL FOUNDATION PLAN 1 1/8" = 1'-0" PERMIT SET S101 evel 1 - Ground Floor 1 /8" = 1 '-0" 00 0 Wall Type Legend Floor Plan Notes Wall Type Symbol - Refer to sheet A400 for partition A. All dimensions are to face of partition, unless shown or noted otherwise 3BND schedule. B. All doors shall be located 6" from face of nearest partition to the inside edge of the jamb at hinge side, uno. Unrated Walls C. All gypsum wallboard and backing board in restrooms to be water-resistant for ® Smoke Partition non -wet areas. o .5 -Hour Fire Partition D. Refer to A701 for interior and exterior finishes. E. Corner guards to be installed on every wall in hallways, rooms, and B.O.H 1-Hour Fire Barrier F. All exposed CIP concrete columns and shear walls in interior spaces (except 41 1-Hour Fire Partition BOH) to be given a high grade architectural finish. G. All exterior glazing to be CW2 unless noted otherwise. ® 2-Hour Fire Barrier H. Concrete finish to be CSC3 for all exposed concrete columns and walls in public 3-Hour Fire Barrier spaces and public corridors. D U DA I PAIN E 0 1-Hour Smoke Barrier 0 2-Hour Smoke Barrier A R C H I T E C T S 2 1 A301 1 1( A200 TA301 2 between u precast wall and slab edge and along vertical joints between walls and precast wall. L IWbHI Provide M seal between I I precast wall and slab edge and along vertical joints between walls and precast wall. II I I I I i I I GAS METER LOCATION AND SIZING? OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FOR REVIEW PURPOSES ONLY This document is the product and exclusive property of Duda/Paine Architects, LLP. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda/Paine Architects, LLP. © Copyright 2020 Duda/Paine Architects, LLP MARK I DATE I DESCRIPTION N ISSUE DATE: PROJECT NUMBER: Floor Plan Level 1 21901 Construction Documents I N N O N O N Al 01 Parking Types Legend Line and Zone Marking Paint 32 1723.A00 Parking Bumper 321713.A00 --------------------- --------- 2p,• EQ L EQ a LOW EMMMON CoO PACT VAN 8' - 6" Low Emmission - 8' - 0" Compact 8' - 0" ADA Van 8' - 0" Van Aisle 5'-0" ADA Aisle EQ EQ ELECTRIC VEHICLE 8' - 0" ADA 8' - 6' Standard i 8' - 6' Electric Vehicle C 00 Parking Garage Notes A. All dimensions are to face of partition, unless indicated or noted otherwise B. Locate doors 6" from face of nearest partition to the inside edge of the jamb at hinge side, uno. C. Protect all exposed pipes, downspouts, and conduit 2 inches or greater with steel pipe guards where located in or adjacent to parking spaces or drive aisles D. All CMU walls adjacent to drive aisles to be provided with 2'-8" crash walls E. All parking garage surfaces to slope to drain; 1% minimum. F. Accessible parking and access aisles to be maximum 2% slope/cross slope. G. Maintain the following vertical clearance: • Loading Dock: 14'-0" • Van Accessible Parking & Access Drive Aisles: 8'-4" • Parking Garage: 7-0" H. Interior Finishes of Open Parking Garage: • Masonry or Concrete Walls and Columns: PT# (exact color TBD) • Exposed Concrete Deck Above: Unfinished • Each parking level to have unique accent color: TBD • Parking Slab Edges: PT34 I. Striped area indicates no parking zone. J. Edge of slab and outside face of column to be painted, color to be selected by architect. Wall Type Legend 3BND Wall Type Symbol - Refer to sheet A400 for partition schedule. Unrated Walls o .5 -Hour Fire Partition ® 1-Hour Fire Barrier 1-Hour Fire Partition ® 2-Hour Fire Barrier ® 3-Hour Fire Barrier 45-Min Smoke Barrier 0 1-Hour Smoke Barrier 0 2-Hour Smoke Barrier Floor Plan Notes A. All dimensions are to face of partition, unless shown or noted otherwise B. All doors shall be located 6" from face of nearest partition to the inside edge of the jamb at hinge side, uno. C. All gypsum wallboard and backing board in restrooms to be water-resistant for non -wet areas. D. Refer to A701 for interior and exterior finishes. E. Corner guards to be installed on every wall in hallways, rooms, and B.O.H F. All exposed CIP concrete columns and shear walls in interior spaces (except BOH) to be given a high grade architectural finish. G. All exterior glazing to be CW2 unless noted otherwise. H. Concrete finish to be CSC3 for all exposed concrete columns and walls in public spaces and public corridors. I. Provide louvered opening from Stair 2 to pressurization shaft; coordinate with Structural. J. Provide 1 /2" gap at each side of doors placed in CIP shear wall. K. Bury all conduit in CIP shear wall so none is exposed. Parking Schedule TYPE ICOUNT GF Compact 1 Standard 3 P1 ADA Van 2 Compact 16 Standard 26 P2 ADA 2 Compact 17 Standard 31 P3 ADA 1 Compact 14 Standard 23 P4 ADA 1 Compact 12 Standard 28 Total Parking 177 Spaces 1 1 1.1 2 2.6 3 4 5 1( A2oo 6 7 8 10 11 _2'- 7" 12' - 8 1 /4" 9' - 0 3/4" 15' - 11 1 /2" 25' - 0 1 /4" 25' - 0 1 /4" 25' - 0 1 /4" 25' - 0 1 /4" 25' - 0 1 /4" 13' - 11 114" 14' - 0" I I I I I I I I I I I Property Line 5 1 A31 1 A31 1 Hatched area represents I I I I I Barrier Cable I extent of split slab system with I 3 I I 5 6 3 05 5220.A00 insulation for floor below. A31 1 A513 513 A513 W4B W4A I A + + + + T + + + + + + + + + + + + + + �� + + + I- + + + I + + + `+ + + + + + + + + + + M +' +\ \ + + + + + + + + + + + `+ + + + + + + + Bollard I 1 - 7, 1/, _J_ - / I / 05 5000 A50 9 o W 14 1 A201 (V �o 1 A300 r-, Ln ZQ CV 01 '11111`11111 O N N O N O N a` W4B W4B W 4A I I I I 4 A315 I I Barrier Cable 05 5220.A00 I I4" House keeping pad — I 2 I A315 2 (A513) I - I + + + + + I + + + + + + I+ + + + + + + + I A + + + +- + I+ + + + + + + 1 I + + - + + + + + + '+ + + \+ + + + + + + + + + + + '+ + + + + + + T;w+ + + + + + + + + + + ' + + + \\ -, + + + + + + + + + + /+ + + + + + `+ + + � + + _+ + _ + + + _ + / + + + _ +`\ +_ + + + + _ + + + + + + + + _ + `-k + C 5' - 11 "� ' - 10' I , I + + + + I+ + + + + + +\ + + + I+ + + + + + + + + + + + + + + + + + + + /+ + + + + \+ + + + + + /+ + + + + + + +` + + + + + + + + + + /+ + + + + + + \\ + + + + + + + + ' IC+ + + + + + + + + + CSO�°GT + + + + Oo1u11P O� + + + ` + + + CQMIp° T C�ONMIF°ACTT +VC I IC�� + + + + + +WVA + COTAPACT + + + + + + + + + + + + + + + + + + +/ + + + + + + + +\ + + + + + + + + + + + + + + + + + + + + +\ + + + + Bollard + + I + + + + + + I + + + + +/' + + + + I+ + + + +\ + I +r�/ + + + + + + + + + + + + +`I\ I I + + + + + + `� 05 5000.A50 + + + + - + + + + + / + + + + + + + + + + + Provide speed ump+stop-+sign,-and + / + + + + + + + + + + + +` + + + + + + + + + + + + + + + + + + + + + + + + + + `\+ mirrors to protec t pedestrians exiting '+ + + + + + + + + + + +. + + + + + + + + + + + + + + + + + + + + \ '- + + + + FSAE Labby + +r + + + + + + + + +` + + + + + + + + + + -f/ + + + + + + + + +\\ + rt + + + rt rt +' + + + + + + + + + + + + + + + ' + + + + I + + + + + +\ + + + I+ + + 4t / N + -'+ + + + I + + + + + + + + + + + + + + + + + / + + + + + + + + + + + + + + + + + + + / +- + + + + + + + / + + + + + + + + + + + + + '+ + + + + + + + + + + + + \+ + + + + / + + + + + + + + / + + + + + + + \+ + + - /+ + + + + + + + + + + + + + \ + + + + /+ +N + + + + + + + + + + + + + + + + + + +` /+ + + + + + + + + + + + + + + \ \+ + + /-� + + + + + + + + 1 2 + + + + + + + + + +ti + + + + + + + + + + + + + + + \ + + + �+ + + + + + + + + + + A410 A321 I I / I \ I / I I W4B + + + + + + + -T + + + + + + + + + + +� + + - +H I + 4"77 + + + + + + + + 334'='J 1 /4 + + + + + + + + + + + + \ ` + '� r334'-0 1 / " + rwi PO l _ ST 1 B Steel Guardrail- \ + + + + + - 5 5213.A01 + + + + + + - + \ +Parking Pay Station I + + I + +,' + + + + + + + + -FEB + + + r _ _ _ _ _ _ _ ° I, 334' 0 1 / I 5'- 2' - 4° I 11 1200.A01+/11 _ - -I Access Door - --- - - - - - - - - I + + + + + + 08 3100.AO1 r + + + + + - ST 1 A + + ty, + + + + ST2 1.0°/ 7 + + + y+ + + + + 2 4_ 1 - + + + + + k + 4/� + \ + +j + + I A405 I' _ _ — I A410 + + + + + + I Y F__ i \ \ r ' + + + + + + + L - - �- - - FSAE LOBBY r o + + \ + + + + ' POl I I I ' J ; '+ �F + I ' - I uw ;3\ ' I - + + + + + I I I I + + + + ` + + F� n + + + + + + + + + + I S 1 I , F B v IR2 �+ W A + + I' + + + I / e + - - - - - -- --- - ---�-_ ++++ ----- ------- I W2 e—+------ + + + +J + + + ------------ 334'-101/2 + + + + 332--111W2B W2 4+ / , I + + + \ ' A311 ® v + i + + + + + + + I + + I + + \ \ 331'-T + + I 327'-11 1 / R2 + + 16.2% A313 A211 \ + N + + ' + + + ' 0 / + + + / v Y + + T 332'-7 7/8" �' ' W2 vOIL v T + + f' + +/' + + + fi fi / v + + + + + + R2 + - I , t W2A + + + Dual drain; structural slab below F2B F2A + + + + + +cc��u+ + + + + + + ' + + _ - slope to drain , \ V a U JO� -L V Ono ' ' + + + + +, + + + + + + +0+ + I �abd� O �a� a �JdcJl�Ooa �aNlc��lOa� E \ + + +,' + + + + + + \T P02 + ' + + + + + + + + + + `� \\ ' '� /' 2'-21/4' \ + + +' + + + + + + + +// + + + + + + + + + + + \ i' \ / / 3' - 2" I + + + + + + + + + \ / + + + + + + + + + Open Below Open Below W2 STORAGE + + + + + P02 + + + + + / + + \ / / 1 1 1 I + + +IL I I I 2 I A201 W4B I I 2 A313 W14 F2B I I I DI Paint east wall black to match slab ed es I \ \ \ \ I N W11 14 At Storage Room, provide parking deck joint between precast wall and slab edge and along vertical joints between walls and precast wall. DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER / LANDSCAPE McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION ISSUE DATE: 10 1 2020 PROJECT NUMBER: 21901 Floor Plan Level 2 - Parking 7'� N Typical Parkin - Level 2 PERMIT SET A 102 1 /8'' = 1'-0'' (1 Al 02 Pent. Roof Penthouse Level_l2 440' - 6'' Level_l 1 431'-0'' Level_l0 421'-6'' Level 9 412'- 011 e l_8_ 402' - 6'' �Level_7_ 393- 0'' �Level_6_ 375- 0" e I_5_ 360'-6'' Level 4 352'- 011 eve I_3_ 343- 6'' Level_2 334'- 0' Mezzanine _ 0'' 1 Exterior Elevation Notes A. See material list on sheet A 701 for alternate finishes. Exterior Elevation Symbols Exterior Assembly Tag W # Type, Refer to Exterior 11 10 9 8 7 6 5 4 3 2.6 2 � l. l 1 Assembly Sheet Smoke Removal Window/Glazing Unit Marking 2' 0" 2' 4 -o° �� -i1 i/a" 1 2s-ol/4' I 2s-o l�4 I 2s o is 1 2s-o1/4' 1 2s-01/4" I 2s-01/4" I 1 iz-s 1/4" I � Glazing to be tempered. Refer to local jurisdiction for identification requirements of fixed openings that can be cleared by fire department for smoke removal purposes. (IBC 403.4.6) Exterior Elevation - North 1 /8" = 1 '-0" .xterior Finish Legend MCM] MWP 1 & 2 MCM 2 WMP 3 MCM 3 MWP 4 DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FOR REVIEW PURPOSES ONLY 0 This document is the product and exclusive property of Duda/Paine Architects, LLP. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda/Paine Architects, LLP. © Copyright 2020 Duda/Paine Architects, LLP MARK I DATE I DESCRIPTION ISSUE DATE: 09 10 2020 PROJECT NUMBER: 21901 Exterior Elevations - North Construction Documents I Co LO M O N O N Co A200 5' - 1 1 " 19' - 6" 5' - 0" 9' - 7'' 16' - 2" 1 A300 Pent. Roof _ 462' - 0" Penthouse 452'- 0'' Level 12 440'_6'' - Level_ll _ 431 ' - 0" 23' - 0 1 /2" 10' - 7' Pent. Roof 462'_0„ - - Penthouse Levell2 440' - 6'' Level 11 Level 10 ■II�i��1i�i�i�-1111111111 �10 Leve19 _ 412' - 0" Level 8 - 402'-6 Level? _ 393' - 0" co Level6 _ 375- 0" Leve14 _ 352' - 0" Level9 412' - 0'' Level8 402'-6'' Level 7 -0„ - - 393'- Level 6 jLeve14 352' - 0" 2 Level I - I A210 �1 e 6 - - Leve12 _ 334' - 0" Mezzanine e I_l 312' - 0" a Exterior Elevation - East 1 /8'' = 1 '-0" 1 Level2 _ _ 334'- o" I I Mezzanine -0'' - - I I I I Level 1 _ J 312' - 0'' A B (B.6 B. B.8 C D E.3 E E.8 F I I 10'-7'' 25'-0'' 6-3" 16'-2" 14'-7'' 19'-6'' —_-_____-_-_______________-_-_-_-_-_-_-_-___ ___-_-_-_-_-___________ -_-_ 1 A210 Exterior Elevation - West 1 /8'' = 1 '-0" DUDA � PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FOR REVIEW PURPOSES ONLY 0 This document is the product and exclusive property of Duda/Paine Architects, LLP. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda/Paine Architects, LLP. © Copyright 2020 Duda/Paine Architects, LLP MARK I DATE I DESCRIPTION ISSUE DATE: 09 10 2020 PROJECT NUMBER: 21901 Exterior Elevations - West & East I N N M O N O N 00 Construction Documents I A201 45 44 Le 43 42 40 39 37 36 35 Le 34 33 32 31 Exterior Elevation - South 1 /8'' = 1 '-0" 1 (1.1 T 2.6 3 4 5 6 7 9 10 11 2' - 7" 11 12' - 8 1 /4" 9' - 0 3/4" 15' - 1 1 1 /2" 25' - 0 1 /4' 25- 0 1 /4" 25' - 0 1 /4" 25' - 0 1 /4' 36' - 11 1 /2" 14' - 0" 2 A213 DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FOR REVIEW PURPOSES ONLY 0 This document is the product and exclusive property of Duda/Paine Architects, LLP. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda/Paine Architects, LLP. © Copyright 2020 Duda/Paine Architects, LLP MARK I DATE I DESCRIPTION ISSUE DATE: 09 10 2020 PROJECT NUMBER: 21901 Exterior Elevations South 1 co M O N O N co Construction Documents I A202 O Project Data Sheet DESERVICES"T DEPARTMENT Development Services Customer Service Center I I Exchange Plaza, Suite400 I Raleigh, NC 27601 1919-996-2495 Litehford Satellite Office 18320- 130 Litchford Road I Raleigh, NC 27601 1919-996-4200 GENERAL INFORMATION Development Name: Home2 + Tru Proposed Use: Mixed Use Property Address(es):603 S. Wilmington St., Raleigh, NC 27601 Wake County Property Identification Number(s) (PIN) for each parcel to which these guidelines will apply: PIN # 1703763353 1 PIN # 1703764322 PIN # 1703764352 1 PIN # What is the project type? oApartment ❑Bank ❑Elderly Facility ❑Hospital §Hotel/Motel ❑Industrial Building ❑Mixed Residential oNon-Residential Condo §Office ❑Religious Institution ❑Residential Condo ❑Retail ❑School ❑Shopping Center ❑Single Family Residential ❑Telecommunication Tower ❑Townhouse ❑Other Scope of work: 184 room hotel and 3,040 SF of office space and parking deck with associated site improvements. FOR APARTMENTS, CONDOS, AND TOWNHOMES ONLY 1. Total number of townhouse lots: Number attached: Number detached: 2. Total number of apartment or condominium units: 3. Total number of Congregate Care or Life Care Dwelling units: 4. Overall total number of dwelling units (from 1-3 above): 5. Number of bedroom units: 1 BR 2BR 3BR 4BR or more 6. Overall unit(s) per acre densities per zoning district(s): DEVELOPMENT TYPE AND SITE DATA TABLE (applicable to all developments) Zoning Information Building Information Zoning District(s): DX-12-UG-CU Proposed use of building(s): Hotel and Office If more than one district, provide acreage of each: Proposed Sq. Ft. of building(s) gross: 182,917 SF Overlay District(s): N/A Existing Sq. Ft. of building(s) gross: 3,606 SF Total site acreage: 0.51 acres Total Sq. Ft. gross (existing and proposed): 182,917 SF Off street parking: Required 0 Provided 0 Proposed height of building(s):140.93' COA (Certificate of Appropriateness) case # N/A FAR (floor area ratio) %:20.8 BOA (Board of Adjustment) case # A - BOA-0038-2019 Building lot coverage %: 20.8 CUD (Conditional Use District) case # Z - N/A Inside City Limits? X Yes ❑ No STORMWATER INFORMATION Existing impervious surface: 0.40 / 17,424 acres/square feet Proposed impervious surface: 0.51 / 22,216 acres/square feet Neuse River buffer: ❑Yes ❑■ No Wetlands: ❑Yes ❑■ No Flood Hazard Area: ❑ Yes ❑■ No If yes, Alluvial Soils: Flood Study: FEMA Map Panel #: 3720170300J Total disturbed area: 0.70 / 30,492 acres/square feet PAGE I OF I WWW.RALEIGHNC.GOV REVISION 03.22.16 RIGHT-OF-WAY OBSTRUCTION NOTES: 1. LANE AND SIDEWALK CLOSURES OR DETOURS: PRIOR TO ANY LANE OR SIDEWALK OBSTRUCTION, THE CONTRACTOR OR ENGINEER SHALL SUBMIT A TRAFFIC CONTROL AND/OR PEDESTRIAN PLAN ALONG WITH A RIGHT-OF-WAY SERVICES APPLICATION TO REQUEST THE OBSTRUCTION PRIOR TO THE START OF WORK. RIGHTOFWAYSERVICES®RALEIGHNC.GOV FOR APPROVAL. 2. THE CITY OF RALEIGH REQUIRES AN APPROVED RIGHT-OF-WAY OBSTRUCTION PERMIT FOR WORK ON ANY PUBLIC STREET OR SIDEWALK AND NCDOT ROAD WITHIN RALEIGH'S JURISDICTION. 3. ALL TRAFFIC CONTROL SIGNAGE AND PRACTICES SHALL ADHERE TO THE MANUAL OF UNIFORM TRAFFIC CONTROL, AND THE LATEST EDITION OF THE NCDOT "STANDARD SPECIFICATION FOR ROADWAY STRUCTURES", NCDOT "ROADWAY STANDARD DRAWING MANUAL", AND THE NCDOT SUPPLEMENT TO THE MUTCD. 4. ALL PUBLIC SIDEWALKS MUST BE ACCESSIBLE TO PEDESTRIANS WHO ARE VISUALLY IMPAIRED AND/OR PEOPLE WITH MOBILITY CONCERNS. EXISTING AND ALTERNATIVE PEDESTRIAN ROUTES DURING CONSTRUCTION SHALL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), THE ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 5. PRIOR TO THE START OF WORK, THE CLIENT SHALL SCHEDULE A PRE -CONSTRUCTION MEETING WITH THE ENGINEERING INSPECTIONS COORDINATOR TO REVIEW THE SPECIFIC COMPONENTS OF THE APPROVED PLAN, AND ENSURE ALL PERMITS ARE ISSUED. 6. ALL PERMITS MUST BE AVAILABLE AND VISIBLE ON SITE DURING THE OPERATION. E DAVIE ST E CABARRUS S V) H V) N w 0 N m In J J O z Z => U) m V) E LENOIR ST SITE E SOUTH ST F- z N V) r% o z => z o x M W � _J N a to O O (n -I m MARTIN LUTHER KING JR BLVD VICINITY MAP N.T.S. ►i 7 i13NIE2 +TRU BOARD OF ADJUSTMENT VARIANCE RALE 603 S WILMINGTON ST RALEIGH, NORTH CAROLINA 27601 SITE PERMIT REVIEW CITY CITY OF OF RALEIGH RALEIGH CASE# CASE# SPR-0146-2020 ASR-0053-2019 PROJECT NUMBER: DATE' I ULY 10 SEE SHEET CO.00 PROJECT NOTES FOR ALL BOARD OF ADJUSTMENT AND APPEARANCE COMMISSION FOR APPROVED DESIGN ADJUSTMENTS AND DESIGN ALTERNATES. BOARD OF ADJUSTMENT DATE OF APPROVAL: 01/13/2020 APPEARANCE COMMISSION DATE OF APPROVAL: 01/16/2020 ZONING CONDITIONS Z-42-14 -SOUTH WILMINGTON STREET/EAST LENOIR STREET: SOUTHEAST QUADRANT OF THE INTERSECTION, AND EXTENDING EASTWARD ON THE SOUTH SIDE OF EAST LENOIR STREET, BEING WAKE COUNTY PINS 1703763353, 1703764322, AND 1703764352. APPROXIMATELY 0.51 ACRE REZONED TO DOWNTOWN MIXED USE-12 STORIES -URBAN GENERAL -CONDITIONAL USE (DX-12-UG-CU). CONDITIONS DATED: JUNE 25, 2015 1. THE FOLLOWING USES SHALL BE PROHIBITED: EMERGENCY SHELTER - ALL TYPES; ADULT ESTABLISHMENT; OUTDOOR RECREATION -ALL TYPES; PASSENGER TERMINAL - ALL TYPES; FOOD TRUCK; PAWN SHOP; VEHICLE SALES/RENTAL - ALL TYPES; DETENTION CENTER, JAIL, PRISON; LIGHT MANUFACTURING - ALL TYPES; SELF-SERVICE STORAGE - ALL TYPES; VEHICLE REPAIR - ALL TYPES; VEHICULAR FUEL SALES; VEHICLE PARTS/ACCESSORIES: REMOTE PARKING FACILITY; ANY DRIVE-THRU OR DRIVE-IN FACILITIES NOT INCLUDING A PORTE COCHERE IN CONNECTION WITH A HOTEL. PROJECT COMPLIANCE: NO USES AS DESCRIBED ABOVE ARE PROPOSED WITH THIS PROJECT. 2. ANY BUILDING ON THE PROPERTY AT LEAST EIGHT (8) STORIES OR ONE HUNDRED FEET (100') IN HEIGHT SHALL INCORPORATE ON THAT EASTERN MOST BUILDING FAt ADE FACING THAT ADJOINING PARCEL DESCRIBED IN THAT DEED RECORDED IN BOOK 14479, PAGE 2287 AND WITH THE ADDRESS OF 118 E. LENOIR STREET A TWELVE FOOT (12') BUILDING STEPBACK ABOVE THE SECOND STORY AND BELOW THE FIFTH STORY. PROJECT COMPLIANCE: THE EASTERN MOST BUILDING FACADE SIDE PROPOSES A 12' STEPBACK FROM THE PROPERTY LINE FACING THE ADJOINING PARCEL. 3. THE MAXIMUM BLANK WALL AREA ON THAT EASTERN MOST BUILDING FACADE FACING THAT ADJOINING PARCEL DESCRIBED IN THAT DEED RECORDED IN BOOK 14479. PAGE 2287 AND WITH THE ADDRESS OF 118 E. LENOIR STREET BELOW THE STEPBACK REQUIRED IN CONDITION 2 SHALT BE FIFTEEN FEET (15') FOR ANY BUILDING ON THE PROPERTY AT LEAST EIGHT (8) STORIES OR ONE HUNDRED FEET (100') IN HEIGHT. PROJECT COMPLIANCE: A SERIES OF REVEALS AND TEXTURES ON THE EASTERN MOST BUILDING FACADE IS INCORPORATED IN THE ELEVATIONS SUCH THAT BLANK WALLS DO NOT EXCEED 15, IN BOTH THE HORIZONTAL AND VERTICAL DIRECTION. 4. AFTER THE EFFECTIVE DATE OF THIS REZONING ORDINANCE, ANY BUILDING ON THE PROPERTY AT LEAST FIVE (5) STORIES OR SEVENTY FIVE FEET (75') IN HEIGHT SHALL PROVIDE ONE OR MORE OF THE FOLLOWING: A GALLERY, AWNING, OR CORNICE ALONG A MINIMUM OF 50% OF THOSE BUILDING FACES ADJOINING S. WILMINGTON STREET AND E. LENOIR STREET. PROJECT COMPLIANCE: A GALLERY IS PROVIDED ALONG LENIOR STREET THAT SPANS 72% OF THE BUILDING FACE, AS WELL AS AN AWNING ALONG S. WILMINGTON STREET SPANNING 89% OF THE BUILDING FACE. 5. ANY VISIBLE PORTION OF AN EXTERIOR ELEVATION OF A PARKING STRUCTURE ABOVE THE GROUND LEVEL SHALL BE CLAD WITH THE SAME BUILDING MATERIALS AS THE PRINCIPAL BUILDING AND, EXCEPT FOR SUCH EXTERIOR TREATMENT AS PRESCRIBED BY THE UDO, SHALL INCLUDE A SOLID WALL AT LEAST FORTY TWO INCHES (42") IN HEIGHT AS MEASURED FROM THE TOP OF EACH PARKING SURFACE. IF THE PARKING STRUCTURE IS ABOVE GRADE, THEN THE OPEN AREA BETWEEN THE TOP OF THE SOLID WALL MEASURING AT LEAST FORTY TWO INCHES (42") IN HEIGHT AND THE NEXT LEVEL OF PARKING SHALL BE SCREENED WITH A WALL, LOUVER OR SIMILAR SCREENING. PROJECT COMPLIANCE: THE PARKING STRUCTURE INCLUDES A 42" HIGH WALL FOR EACH LEVEL. A SERIES OF LOUVERS OR METAL MESH WILL BE USED TO SCREEN THE OPEN AREA. 6. PRIOR TO ISSUANCE OF A BUILDING PERMIT FOR NEW DEVELOPMENT, A TRANSIT EASEMENT SHALL BE DEEDED TO THE CITY AND RECORDED IN THE WAKE COUNTY REGISTRY. PRIOR TO RECORDATION OF THE TRANSIT EASEMENT, THE DIMENSIONS (NOT TO EXCEED FIFTEEN FEET (15') IN DEPTH AND TWENTY FEET (20') IN WIDTH) AND LOCATION OF THE EASEMENT ALONG WILMINGTON STREET SHALL BE APPROVED BY THE PUBLIC WORKS DEPARTMENT AND THE EASEMENT DOCUMENT APPROVED BY THE CITY ATTORNEY'S OFFICE. PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY AND AT THE REQUEST OF THE PUBLIC WORKS DEPARTMENT, A TRANSIT SHELTER SHALL BE CONSTRUCTED UPON THE TRANSIT EASEMENT. IN LIEU OF DEEDING AN EASEMENT AND CONSTRUCTION OF A TRANSIT SHELTER, WITH THE CONSENT OF THE PUBLIC WORKS DEPARTMENT AND SUBJECT TO THE APPROVAL OF THE RALEIGH CITY COUNCIL OR NC DEPARTMENT OF TRANSPORTATION, A TRANSIT SHELTER MAY BE CONSTRUCTED IN THE PUBLIC RIGHT-OF-WAY AT THE SOLE EXPENSE OF THE OWNER OF THE REZONED LAND IN SATISFACTION OF THIS CONDITION. PROJECT COMPLIANCE: A PROPOSED TRANSIT EASEMENT AND SHELTER IS LOCATED ALONG S. WILMINGTON STREET. 7. PRIOR TO ANY EXCAVATION ON THE SUBJECT PROPERTIES, DEMOLITION OF ANY BUILDING OR PORTION THEREOF ON THE SUBJECT PROPERTY, OR ANY ACTIVITY ALLOWED BY SUBSECTIONS G. AND OF LIDO SECTION 10-2.7.A.2, THE EXISTING BUILDING LOCATED AT 112 E. LENOIR STREET AND THE TWO STORY PORTION OF EXISTING BUILDING LOCATED AT 114 E. LENOIR STREET SHALL BE RELOCATED AND A SUBSEQUENT ARCHAEOLOGICAL SURVEY CONDUCTED ON THE REZONED PROPERTIES IN DIRECT CONSULTATION WITH THE RALEIGH HISTORIC DEVELOPMENT COMMISSION PROJECT COMPLIANCE: THE BUILDINGS LOCATION AT 112 AND 114 E. LENOIR STREET WERE RELOCATED PRIOR TO SUBMITTAL OF THIS ADMINISTRATIVE SITE REVIEW AND AS SUCH THIS ZONING CONDITION DOES NOT APPLY TO THIS SUBMITTAL. SITE DATA DPA-17010 2020 PHYSICAL ADDRESS: 603 S WILMINGTON ST, RALEIGH NORTH CAROLINA 27601 PARCEL PIN: 1703763353 ZONING: DX-12-UG-CU DOWNTOWN MIXED USE - 12 STORIES - URBAN GENERAL - CONDITIONAL USE OVERLAY DISTRICT: NONE WATERSHED: WALNUT CREEK SITE AREA 22,009 SF / 0.51 AC FLOODWAY/FLOODPLAIN: NONE BUILDING DATA: PROPOSED USE: OFFICE + HOTEL PROPOSED OFFICE: 3,040 SF PROPOSED HOTEL ROOMS: 184 ROOMS PARKING DATA: VEHICLE PARKING REQUIRED: 93 SPACES OFFICE PARKING: 0 SPACES (PER UDO SEC. 7.1.3C) HOTEL PARKING: 93 SPACES (0.5/BEDROOM) PROPOSED: 121 STANDARD SPACES (IN PARKING DECK) 50 COMPACT SPACES (IN PARKING DECK)* 4 ADA SPACES (IN PARKING DECK) 2 ADA VAN SPACES (IN PARKING DECK) *PERCENTAGE OF COMPACT SPACES WITHIN PARKING DECK = 50 177 SPACES = 28.2% ACCESSIBLE PARKING REQUIRED: 6 SPACES (CAR AND VAN) VAN SPACES: 1 SPACES PROPOSED: 6 SPACES (CAR AND VAN) VAN ACCESSIBLE: 2 SPACES BIKE PARKING REQUIRED: 14 LONG TERM SPACES; 4 SHORT TERM SPACES OFFICE: LONG TERM: 4 SPACES (1/5,000 SF, MIN. OF 4 SPACES) SHORT TERM: 4 SPACES (10,000 SF, MIN. OF 4 SPACES) HOTEL: LONG TERM: 10 SPACES (1/20 BEDROOM) SHORT TERM: 0 SPACES PROPOSED: 14 LONG TERM SPACES; 4 SHORT TERM SPACES BUILDING + PARKING BUILD -TO REQUIRED SETBACKS LENOIR ST (PRIMARY STREET): 148 LF (70% BUILDING WIDTH IN BUILD -TO) WILMINGTON ST (PRIMARY STREET): 74 LF (70% BUILDING WIDTH IN BUILD -TO) PROVIDED LENOIR ST (PRIMARY STREET): 148 LF (70% BUILDING WIDTH IN BUILD -TO) WILMINGTON ST (PRIMARY STREET): 80 LF (76% BUILDING WIDTH IN BUILD -TO) PARKING SETBACK LENOIR ST (PRIMARY STREET): 10, WILMINGTON ST (PRIMARY STREET): 10, SIDE LOT LINE: 3' REAR LOT LINE: 3' EXISTING IMPERVIOUS: 0.40 AC. PROPOSED IMPERVIOUS ALLOCATION: 0.51 AC. (100% OF PROJECT AREA) BUILDING HEIGHT MAXIMUM ALLOWED: 12 STORY (150') PROPOSED: 12 STORY (140') TREE CONSERVATION NO TREE CONSERVATION SHALL BE REQUIRED PER UDO SECTION 9.1.2 AS THE EXISTING LOT IS LESS THAN 2 ACRES IN SIZE. OUTDOOR AMENITY AREA REQUIRED: 2,450 SF (10%SITE AREA) PROPOSED: 2,504 SF (11.4% SITE AREA) BLOCK PERIMETER: 1,513 LF (2,000 LF MAX) 1. THE MINIMUM CORNER CLEARANCE FOR A DRIVEWAY FROM THE CURB LINE OF INTERSECTING STREETS SHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY OF THE CURB. NO DRIVEWAYS SHALL ENCROACH ON THIS MINIMUM CORNER CLEARANCE. RSDM SECTION 6.5.2.D. 2. WITHIN THE AREA OF A DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMING OR PARKED VEHICLES BETWEEN THE HEIGHTS OF TWENTY-FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB ELEVATION OR THE NEAREST TRAVELED WAY, IF NO CURBING EXISTS. 1. THE DEVELOPER ACKNOWLEDGES THAT THEY HAVE REVIEWED AND ARE IN COMPLIANCE WITH THE REQUIREMENTS SET FORTH IN THE SOLID WASTE DESIGN MANUAL. 2. THE SOLID WASTE REMOVAL FOR THIS PROJECT WILL BE HANDLED BY A PRIVATE SERVICE. 3. REFUSE WILL BE COLLECTED IN ROLL -OUT TRASH AND RECYCLING CARTS THAT WILL BE BROUGHT OUT CURB SIDE FOR PICKUP. PICKUP WILL BE PROVIDED TWICE A WEEK. Know what's below. Cal I before you dig. SHEET INDEX C0.00 ADMINISTRATIVE APPROVAL LETTER C0.01 PROJECT NOTES C1.00 EXISTING CONDITIONS C1.01 DEMOLITION PLAN C2.00 SITE PLAN C2.01 STREET HARDSCAPE PLAN C3.00 GRADING AND STORM DRAINAGE PLAN C3.01 DETAILED GRADING PLAN C4.00 UTILITY PLAN C6.00 EROSION CONTROL PLAN - STAGE 1 C6.01 EROSION CONTROL PLAN - STAGE 2 C6.02 EROSION CONTROL PLAN - STAGE 3 C7.00 PEDESTRIAN ACCESS AND TRAFFIC CONTROL PLAN C8.00 SITE DETAILS C8.01 SITE & STORM DRAINAGE DETAILS C8.02 EROSION CONTROL DETAILS C8.03 SANITARY SEWER DETAILS C8.04 WATER DETAILS C8.05 WATER DETAILS C9.00 STORMWATER CONTROL MANAGEMENT PLAN VIEW AND NOTES C9.01 STORMWATER CONTROL MANAGEMENT DETAILS L2.01 HARDSCAPE PLAN - STREET LEVEL L2.02 FURNITURE & PLANTING PLAN - 6TH FLOOR L2.03 PAVING PLAN - 6TH FLOOR L4.01 HARDSCAPE DETAILS 1 L4.02 HARDSCAPE DETAILS 2 L5.01 LANDSCAPE PLAN L5.02 LANDSCAPE DETAILS A-101 GROUND FLOOR PLAN A-101.A MEZZANINE LEVEL A-102 FLOOR PLAN - LEVEL 2 PARKING A-102B LEVEL 2 TURNING RADIUS A-103 FLOOR PLAN - LEVEL 3 PARKING A-104 FLOOR PLAN - LEVEL 4 PARKING A-105 FLOOR PLAN - LEVEL 5 PARKING A-106 AMENITY LEVEL 6 A-107 HOTEL LEVELS 7 - 8 A-108 HOTEL LEVELS 9-10 A-109 HOTEL LEVELS 11-12 A-200 EXTERIOR ELEVATIONS - NORTH & WEST A-201 EXTERIOR ELEVATIONS - SOUTH & EAST A-210 ELEVATION - GROUND FLOOR TRANSPARENCY CALC. A-220 ELEVATIONS - GARAGE OPENNESS CALCULATIONS A-221 UPPER FLOOR TRANSPARENCY CALC. A-311 WALL SECTIONS -ZONING CONDITIONS A-311.A ZONING CONDITIONS DIAGRAM PUBLIC IMPROVEMENT QUANTITIES PHASE NUMBER: N/A NUMBER OF LOTS: 1 LOT NUMBER(S) BY PHASE N/A NUMBER OF UNITS: 184 LIVABLE BUILDINGS: 1 OPEN SPACE: 0 NUMBER OF OPEN SPACE LOTS: 0 PUBLIC WATER (LF) 0 PUBLIC SEWER (LF) 0 PUBLIC STREET (LF) - FULL 0 PUBLIC STREET (LF) - PARTIAL 0 PUBLIC SIDEWALK (LF) 330 STREET SIGNS (EA) 0 WATER SERVICE STUBS (QTY) 1 SEWER SERVICE STUBS (QTY) 1 CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. ATTENTION CONTRA C TORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contactina the Public Works Department at (919) 996-2409. and the Public Utilities Department at (919) 996-4540 at least prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. ELECTRONIC APPROVAL: THIS APPROVAL IS BEING ISSUED ELECTRONICALLY. THIS APPROVAL IS VALID ONLY UPON THE SIGNATURE OF A CITY OF RALEIGH REVIEW OFFICER BELOW. THIS CITY WILL RETAIN A COPY OF THE APPROVED PLANS. ANY WORK AUTHORIZED BY THIS APPROVAL MUST PROCEED IN ACCORDANCE WITH THE PLANS KEPT ON FILE WITH THE CITY. THIS ELECTRONIC APPROVAL MAY NOT BE EDITED ONCE ISSUED. ANY MODIFICATIONS TO THIS APPROVAL ONCE ISSUED WILL INVALIDATE THIS APPROVAL. CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER FINAL DRAWING - RELEASED FOR CONSTRUCTION DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 A iot�ulriet�r Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Alllea I -Ire rrorecrlon 80 Rupert Rd. Raleigh, NC 27603 } O 2 �. ,N CARC,, �.. •.......57 . • i o .•FEs�../�•.. ' _ i•� 3EA:- 0 74J55 �.: IN n- nWl W � ' - O v ! 0 O N - 11-- ` MU Z E T�1 ^ W V) - J LPL O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION 1 2 3 4 I PROJECT NUMBER: 219011 SITE PERMIT REVIEW FOR: HOME2+TRU RALEIGH, NORTH CAROLINA 27601 PROJECT NUMBER: DPA-17010 Construction Documents 6�op Administrative City of Raleigh f �y Development Services Department One Exchange Plaza '`•yo\ ire Approval Action Raleigh, NC 27602 CAR°y Case File / Name: ASR-0053-2019 (sral 9hnc.go2 currentplanning@raleighnc.gov HOME2 + TRU RALEIGH www.raleighnc.gov LOCATION: This .51 acre site zoned DX-12-UG-CU (Z-42-14) is located at 603 S. Wilmington Street, on the southeast corner of the intersection of East Lenoir Street and South Wilmington Street. REQUEST: Development of a 187,332 gross square foot, 186 unit hotel with office space with associated site improvements. One Administrative Alternate has been approved by the Planning Director, and two Design Adjustments have been approved by the Board of Adjustment for this project, noted below. AAD-1-20 - Adjustment of the Build -To requirements of (1.5.2), and Building Massing standards of (3.3.3) (AAD-1-20). BOA-0038-2019 - Variance to the 10' minimum sidewalk width (11.2.2 E), relief from the minimum distances required between driveways and intersections (9.5), relief from the uncovered amenity area (1.5.3), relief from the minimum 10' width of amenity areas (1.5.3), partial relief from the required adjacency of amenity areas to the public sidewalk (1.5.3), and relief from compact parking space standards of (7.1.6 B2). A-148-2019 - Relief from forward motion of of ingress and egress (8.3.5 A 3), relief from right of way width requirements of both streets (8.4.6 A), relief from minimum driveway spacing (8.3.5 C 3 c), and relief from the cross access requirements of 8.3.5 D). DESIGN ADJUSTMENT(S)/ ALTERNATES, ETC: N/A FINDINGS: City Administration finds that this request, with the below conditions of approval being met, conforms to the Unified Development Ordinance. This approval is based on a preliminary plan dated April 8, 2020 by MCADAMS. CONDITIONS OF APPROVAL and NEXT STEPS: This document must be applied to the second sheet of all future submittals except for final plats. This is a preliminary plan and as such no permits have been issued with this approval. To obtain permits and/or completion of the project, the following steps are required: 21 SITE PERMITTING REVIEW - For land disturbance of 12,000 square feet or greater, public or private infrastructure, shared stormwater devices, etc. Site Permitting Review may be submitted upon receipt of this signed approval document. The following items are required prior to approval of Site Permitting Review plans: General 1. The streetscape shall meet the requirements of the downtown master plan. The scoring of the sidewalk must be provided. It will be confirmed at site permitting review. Engineering ASR-0053-2019 HOME2 + TRU RALEIGH Administrative Approval Action Case File / Name: ASR-0053-2019 HOME2 + TRU RALEIGH The following items must be approved prior to the issuance of building permits: General 1. A demolition permit shall be obtained. 1 City of Raleigh Development Services Department One Exchange Plaza Raleigh, NC 27602 (919)996-2492 currentplanning@raleighnc.gov www.raleighnc.gov 2. A recombination map shall be recorded prior to or in conjunction with the recording of lots, recombining the existing lots into a single tract. 3. Prior to grading and/or demolition two existing buildings shall be relocated and the completion of an Archeological survey (Z-42-14, #7) 4. Comply with all conditions of Z-42-14. Engineering 5. A public infrastructure surety shall be provided to the City of Raleigh Development Services — Development Engineering (UDO 8.1.3). 6. A right-of-way obstruction permit shall be obtained from Right-of-way Services for any construction activity within the right-of-way. Public Utilities 7. A plat must be recorded at the Wake County Register of Deeds office for all utility easement dedications. Stormwater 8. A surety equal to 125% of the cost of the construction of a stormwater device shall be paid to the Engineering Services Department (LIDO 9.2.2.D.1.d). 9. A payment equal to twenty-four percent (24%) of the estimated cost of constructing all stormwater control facilities shown on the development plans shall be paid by the developer to the City stormwater facility replacement fund (UDO 9.2.2.G.3). 10. All stormwater control measures and means of transporting stormwater runoff to and from any nitrogen and stormwater runoff control measures shall be shown on all plats for recording as private drainage easements (LIDO 9.2). 11. An encroachment agreement for Stormwater pipes within the public right-of-way shall be approved by City Council and the City Council approved encroachment agreement shall be filed with the Development Services Department, and the encroachment agreement shall be recorded with the Wake County Register of Deeds. A recorded copy of these documents must be provided to the Development Services Department. Urban Forestry ASR-0053-2019 HOME2 + TRU RALEIGH O O (" 5 O CV O CN CV 00 3 °F Administrative City of Raleigh Development Services Department /� Action One Exchange Plaza Approval Action Raleigh, NC 27602 (919) 996-2492 Case File / Name: ASR-0053-2019 currentplanning@raleighnc.gov HOME2 + TRU RALEIGH www.raleighnc.gov 2. A right-of-way obstruction permit must be obtained from Right-of-way Services prior to the commencement of any construction activities within the right-of-way. Stormwater 3. A nitrogen offset payment must be made to a qualifying mitigation bank (UDO 9.2.2.13) 4. A surety equal to of the cost of clearing, grubbing and reseeding a site, shall be paid to the City (UDO 9.4.4). 5. A stormwater control plan with a stormwater operations and maintenance manual and budget shall be approved (UDO 9.2). 0 LEGAL DOCUMENTS - Email to legaldocumentreview@raleighnc.gov. Legal documents must be approved, executed, and recorded prior to or in conjunction with the recorded plat on which the associated easements are shown. Copies of recorded documents must be returned to the City within one business day of recording to avoid withholding of further permit issuance. 121 Sidewalk Easement Required I I I Transit Easement Required 0 RECORDED MAP(S) - Submit plat to record new property lines, easements, tree conservation areas, etc.). Plats may be submitted for review when the Site Permitting Review plans, if required, have been deemed ready for mylar signature. The following items must be approved prior to recording the plat: Engineering 1. A sidewalk deed of easement for any public sidewalk on private property shall be approved by City staff, and the location of the easement shall be shown on the map approved for recordation. The deed of easement shall be recorded at Wake County Register of Deeds within one day of recordation of the plat. A recorded copy of this document shall be provided to the Development Services Department within one day from authorization of lot recordation. If a recorded copy of this document is not provided, further recordings and building permit issuance will be withheld. Transportation 2. A transit deed of easement shall be approved by City staff and the location of the easement shall be shown on a plat approved for recordation. The deed of easement shall be recorded at Wake County Register of Deeds within one day of recordation of the recorded plat. A recorded copy of this document must be provided to the Development Services Department within one day from authorization of lot recording. If a recorded copy of the document is not provided, further recordings and building permit issuance will be withheld. 0 BUILDING PERMITS - For buildings and structures shown on the approved plans. Commercial building permit plans must include the signed, approved Site Permitting Review plans attached, if applicable. Permit sets may be reviewed prior to the recordation of required plats, but cannot be approved. ASR-0053-2019 HOME2 + TRU RALEIGH 2 4 �F Administrative City of Raleigh Development Services Department One Exchange Plaza Approval Action Raleigh, INC 27602 Case File / Name: ASR-0053-2019 (9ral 9hnc.go2 currentplanning@raleighnc.gov HOME2 + TRU RALEIGH www.raleighnc.gov 12. A tree impact permit must be obtained for the approved streetscape tree installation in the right of way. This development proposes (2) street trees along S. Wilmington St. and (5) street trees along Lenoir St. All (7) street trees are in tree pits. The following are required prior to issuance of building occupancy permit: General 1. All street lights and street signs required as part of the development approval are installed. 2. Required public right-of-way infrastructure improvements shall be, at a minimum, sufficiently completed to provide the necessary, safe emergency and vehicular access. Stormwater 3. As -built drawings and associated forms for all Stormwater devices are accepted by the Engineering Services Department (UDO 9.2.2.D.3). EXPIRATION DATES: The expiration provisions of UDO Section 10.2.8 E, including the ability to request extensions in the expiration date, apply to this site plan. If significant construction has not taken place on a project after administrative site review approval, that approval may expire and be declared void, requiring re -approval before permits may be issued. To avoid allowing this plan approval to expire the following must take place by the following dates: 3-Year Expiration Date: May 14, 2023 Obtain a valid building permit for the total area of the project, or a phase of the project. 4-Year Completion Date: Within four years after issuance of the first building permit for the site plan, the construction of the entire site plan must be completed unless an applicant has been granted vested rights. Failure to complete construction within this specified time frame shall automatically void the approved site plan for which no building permits have been issued. I hereby certify this administrative decision. Signed:Date: Development Services Dir/Designee Staff Coordinator: Michael Walters ASR-0053-2019 HOME2 + TRU RALEIGH 05/14/2020 4 SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 ,,%0,1 u u 111",� �. �N CARC,,'�. ,._ O ES.. i• v 0 -3i 355 N N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION 1 PROJECT NUMBER: 21901 1 ADMINISTRATIVE APPROVAL LETTER C0600 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER ADMINISTRATIVE ALTERNATES %AAD-1 -20 1. ADMINISTRATIVE ALTERNATE GRANTED FOR UDO SECTIONS 1.5.6. BUILD -TO. 2. ADMINISTRATIVE ALTERNATE GRANTED LIDO SECTION 3.3.3. BUILDING MASSING ALONG S WILMINGTON ST AND E LENOIR ST. DESIGN ADJUSTMENTS (BOA-0038-2019) APPROVED AS NOTED: • A REQUEST FOR A VARIANCE FROM THE REQUIREMENT SET FORTH IN SECTION 11.2.2.E. OF THE RALEIGH STREET DESIGN MANUAL THAT THE MINIMUM 10' SIDEWALK DIMENSION WIDTH NOT CONTAIN ANY OBSTACLES IN ORDER TO CONSTRUCT A SIDEWALK ALONG LENOIR STREET OBSTRUCTED BY SUPPORT COLUMNS; • A 120' VARIANCE AND A 90' VARIANCE FROM THE MINIMUM DISTANCE REQUIREMENTS SET FORTH IN SECTION 9.5. OF THE RALEIGH STREET DESIGN MANUAL, WHICH REQUIRES DRIVEWAYS ON A MAJOR STREET TO BE LOCATED AT LEAST 200' FROM THE INTERSECTION WITH A MIXED -USE STREET IN ORDER TO CONSTRUCT A DRIVEWAY ON S WILMINGTON ST THAT IS 80' FROM THE INTERSECTION OF LENOIR ST AND 110' FROM THE INTERSECTION OF SOUTH ST; • A VARIANCE FOR COMPLETE RELIEF FROM SECTION OF THE UNIFIED DEVELOPMENT ORDINANCE WHICH PROHIBITS AMENITY AREA IN THE DX- DISTRICT FROM BEING COVERED; • A VARIANCE TO SECTION 1.5.3. OF THE UNIFIED DEVELOPMENT ORDINANCE WHICH STATES THAT OUTDOOR AMENITY AREA MUST BE AT LEAST 10 FEET IN WIDTH AND LENGTH AND A VARIANCE TO THE REQUIREMENT THAT AMENITY AREA FOR A GENERAL BUILDING OR MIXED USE BUILDING IN THE DX - DISTRICT THAT IS 50% OR MORE NON-RESIDENTIAL IN FLOOR AREA BE LOCATED CONTIGUOUS TO THE PUBLIC SIDEWALK AND BE VISUALLY PERMEABLE FROM THE PUBLIC RIGHT-OF-WAY TO ALLOW A PORTION OF THE REQUIRED OUTDOOR AMENITY AREA TO BE LOCATED ON A SIXTH -FLOOR TERRACE ADJACENT TO BOTH THE LENOIR AND WILMINGTON STREETS RIGHT OF WAY, WITH THE PORTION OF SUCH UNCOVERED TERRACE ALONG LENOIR STREET BEING 8.25' IN UNCOVERED WIDTH; • A VARIANCE TO SECTION 7.1.6.B.2 OF THE UNIFIED DEVELOPMENT ORDINANCE WHICH STATES A MAXIMUM OF 30% OF THE PARKING SPACES WITHIN A STRUCTURED PARKING FACILITY MAY BE COMPACT SPACES AND THAT NO MORE THAN 2 COMPACT SPACES MAY ABUT EACH OTHER TO ALLOW A MAXIMUM OF 35% OF SPACES PROVIDED IN EXCESS OF UDO REQUIREMENTS TO BE COMPACT PARKING SPACES AND THAT THOSE COMPACT SPACES BE LIMITED TO FOUR CONTIGUOUS SPACES IN ORDER TO CONSTRUCT 207,304 SQUARE FOOT GENERAL BUILDING FOR OFFICE AND HOTEL USES ON A ACRE PROPERTY ZONED AND LOCATED AT 114 E. LENOIR, 112 LENOIR AND 603 S. WILMINGTON. DESIGN ADJUSTMENTS CA-148-19� APPROVED AS NOTED: • A REQUEST FOR A DESIGN ADJUSTMENT FOR COMPLETE RELIEF FROM THE REQUIREMENT SET FORTH IN SECTION 8.3.5.A.3. THAT VEHICLES INGRESS AND EGRESS THE SITE IN A FORWARD MOTION; • A 28' DESIGN ADJUSTMENT FROM THE RIGHT-OF-WAY WIDTH REQUIREMENTS FOR SOUTH WILMINGTON STREET AN AVENUE 4-LANE, PARALLEL PARKING STREET, SET FORTH IN SECTION 8.4.6.A. OF THE UNIFIED DEVELOPMENT ORDINANCE TO RETAIN THE EXISTING TRAVELWAY AND A RIGHT-OF-WAY WIDTH OF 66'; • A 3.5' DESIGN ADJUSTMENT FROM THE RIGHT- OF -WAY WIDTH REQUIREMENTS FOR LENOIR STREET A MAIN STREET, PARALLEL PARKING STREET, SET FORTH IN SECTION 8.4.5.D. TO RETAIN THE EXISTING TRAVELWAY AND A RIGHT-OF-WAY WIDTH OF 66'; • A 166' DESIGN ADJUSTMENT AND A 182' DESIGN ADJUSTMENT FROM THE MINIMUM DRIVEWAY SPACING REQUIREMENT SET FORTH IN UDO SECTION 8.3.5.C.3.C, WHICH REQUIRES AT LEAST 200' BETWEEN DRIVEWAYS TO INSTALL A DRIVEWAY ONTO S WILMINGTON ST WITH A MINIMUM SPACING OF 34' AND A DRIVEWAY ONTO E LENOIR ST WITH A MINIMUM SPACING OF 18', RESPECTIVELY; • A DESIGN ADJUSTMENT FOR COMPLETE RELIEF FROM THE CROSS -ACCESS REQUIREMENTS OF SECTION 8.3.5.D. O O (" 5 O CV O CN CV co SITE PLAN NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 4. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO THE SUBSTITUTION OF ALTERNATE EQUIPMENT. 5. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 6. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION OR TO THE SATISFACTION OF THE OWNER BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 7. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 8. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 9. PRIOR TO STARTING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT FOR EROSION CONTROL AND ENGINEERING INSPECTIONS PRIOR TO ANY WATER OR SEWER ABANDONMENT, REMOVAL OR INSTALLATIONS. GENERAL NOTES: 1. OWNER RESERVES RIGHT TO ADJUST SITE IMPROVEMENTS AND MODIFY BUILDING FOOTPRINTS FROM THOSE SHOWN ON THIS PLAN. 2. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH PUBLIC WORKS, ENGINEERING INSPECTIONS DEPARTMENT (919) 996-6824, AND A REPRESENTATIVE OF THE ENGINEER AND OWNER. 3. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE SITE CONTRACTOR, AFTER PERMISSION BY EROSION CONTROL INSPECTOR. 4. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE AND ENGINEER IMMEDIATELY. STORM DRAINAGE NOTES: 1. ALL STORM DRAINAGE PIPES SHOWN ARE TO BE CLASS III REINFORCED CONCRETE (RCP) UNLESS NOTED OTHERWISE. 2. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF RALEIGH AND NCDOT STANDARDS. 3. ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4. ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 5. ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 6. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 7. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 8. MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE OR GEOTECHNICAL ENGINEER AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 9. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. DEMOLITION NOTES: 1. THE INFORMATION SHOWN WAS TAKEN FROM DESIGN DRAWINGS AND FIELD SURVEY WHEREVER POSSIBLE. ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, EASEMENTS, AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 2. THE LOCATIONS OF ALL UTILITIES SHOWN ON THIS PLAN ARE BASED ON THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF UTILITIES WITH THE UTILITY OWNERS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 3. ALL DEMOLITION MATERIAL WILL BE REMOVED FROM THE SITE AND DISPOSED OF IN A PROPER LOCATION AND METHOD AS DESIGNATED BY THE LOCAL AUTHORITIES. 4. CONTRACTOR SHALL NOTIFY NC811 (811 OR 800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 6. THE CONTRACTOR SHALL, AT ALL TIMES, KEEP THE PREMISES AND ADJACENT ROADWAYS FREE FROM ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIM, HIS EMPLOYEES OR HIS WORK. ALL DEBRIS SHALL BE REMOVED FROM THE PROJECT SITE ON A DAILY BASIS. GRADING NOTES: 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONTRACTOR SHALL NOTIFY "NC811" (81 1) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC81 1 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT, THE ENGINEER AND A REPRESENTATIVE OF THE OWNER. 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. THESE SOILS SHALL BE COMPACTED TO THE STANDARD PROCTOR MAXIMUM DRY DENSITY UNLESS OTHERWISE RECOMMENDED BY THE GEOTECHNICAL ENGINEER. RALEIGH STANDARD UTILITY NOTES: 1. ALL SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT HANDBOOK, CURRENT EDITION (INCLUDING STANDARDS AND SPECIFICATIONS). 2. UTILITY SEPARATION REQUIREMENTS: 2.1. A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER AND ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS N IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED AND INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. 2.2. WHEN INSTALLING WATER AND/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER AND MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. 2.3. WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATER MAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED AND INSTALLED TO WATERLINE SPECIFICATIONS. 2.4. 5' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER AND STORM SEWER FACILITIES UNLESS DIP IS SPECIFIED FOR SANITARY SEWER. 2.5. MAINTAIN 18" MINIMUM VERTICAL SEPARATION AT ALL WATERMAIN AND RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MINIMUM VERTICAL SEPARATION AT ALL SANITARY SEWER AND RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS AND A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (REF: CORPUD DETAILS W-41 & S-49) 2.6. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER AND SEWER FACILITIES WITH 18" MINIMUM VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW AND APPROVAL OF AN AMENDED PLAN AND OR PROFILE BY THE CORPUD PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER AND SEWER SERVICE TO EXISTING RESIDENCES AND BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24-HOUR ADVANCE NOTICE TO THE CORPUD. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS AND SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL RE -USE MAINS.. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER AND SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CORPUD. THIS INCLUDES ABANDONING TAP AT MAIN AND REMOVAL FROM R.O.W. OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. INSTALL PROPERLY SIZED WATER SERVICES WITH METERS LOCATED AT R.O.W. WITHIN A 2'X2' (OR APPROPRIATE SIZED EASEMENT) IMMEDIATELY ADJACENT. IT IS THE APPLICANT'S RESPONSIBILITY TO PROPERLY SIZE THE WATER SERVICE FOR EACH CONNECTION TO PROVIDE ADEQUATE FLOW AND PRESSURE. 8. INSTALL 4" PVC SEWER SERVICES AT 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT R.O.W. OR EASEMENT LINE AND SPACED EVERY 100 LF MAX. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0' ABOVE THE NEXT UPSTREAM MANHOLE. 10. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE AND/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND AND/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 11. NCDOT ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS AND SERVICE TAPS) WITHIN STATE R.O.W. PRIOR TO CONSTRUCTION. 12. GREASE INTERCEPTOR/OIL WATER SEPARATOR SIZING CALCULATIONS AND INSTALLATION SPECIFICATIONS SHALL BE APPROVED BY THE CORPUD FOG PROGRAM COORDINATOR PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTACT TIM BEASLEY 919.996.2334 OR TIMOTHY. BEASLEY®RALEIGHNC.GOV FOR MORE INFORMATION. 13. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET ASSE STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HARTLEY AT 919.996.5923 OR JOANIE.HARTLEY®RALEIGHNC.GOV FOR MORE INFORMATION. Know what's below. Cal I before you dig. SANITARY SEWER NOTES: 1. ALL SEWER SERVICES IN PUBLIC R.O.W. SHALL BE INSTALLED BY A LICENSED UTILITY CONTRACTOR. 2. BEFORE COMMENCING ANY EXCAVATION IN ANY HIGHWAY, STREET, PUBLIC SPACE, OR IN AN EASEMENT, THE NORTH CAROLINA UNDERGROUND DAMAGE PREVENTION ACT REQUIRES NOTIFICATION OF EACH UTILITY OWNER HAVING U.G. UTILITIES LOCATED IN THE PROPOSED AREA TO BE EXCAVATED, EITHER ORALLY OR IN WRITING, NOT LESS THAN 2 DAYS NOR MORE THAN 10 WORKING DAYS PRIOR TO STARTING OF THE INTENT TO EXCAVATE. 3. ANY EXISTING UTILITY APPURTENANCES SHALL NOT BE REUSED ON PROPOSED IMPROVEMENTS. 4. ALL PROPOSED SEWER ON THIS SITE IS TO BE PRIVATE. 5. ALL 8" SEWER SHALL BE PVC SDR-35 AND ALL 6" SEWER SHALL BE PVC SCH.40 UNLESS OTHERWISE SPECIFIED ON THE PLANS. 6. MINIMUM COVER TO FINISHED GRADE OF 5 FEET IN TRAFFIC AREAS TO BE PROVIDED FOR ALL COLLECTOR LINES 4 INCHES AND LARGER. IF LESS THAN 5 FEET OR DEEPER THAN 12', DUCTILE IRON PIPE SHALL BE REQUIRED WITH TYPE 1 BEDDING TO A COVER AT A MIN OF 3 FEET. 7. MINIMUM SLOPE FOR THE 8 INCH SANITARY SEWER COLLECTION LINE IS 0.50% AND THE MINIMUM SLOPE FOR THE 6 INCH SANITARY SEWER SHALL BE NO LESS THAN 1.0% (WITH CLEANOUTS EVERY 100 LINEAL FEET). 8. SEWER CLEANOUTS ARE NOT ALLOWED IN DRIVEWAYS, SIDEWALKS AND PARKING LOTS UNLESS SHOWN OTHERWISE. CLEANOUTS WITHIN ASPHALT PAVED TRAFFIC AREAS SHALL BE INSTALLED IN TRAFFIC RATED MINI -MANHOLES, DOMESTICALLY CAST. 9. ALL EXISTING UTILITIES ARE SHOWN AT APPROXIMATE LOCATIONS. CONTRACTOR SHALL VERIFY ACTUAL LOCATION AND DEPTHS IN FIELD PRIOR TO BEGINNING CONSTRUCTION. 10. UTILITY SLEEVES SHALL BE PVC (SCH. 40). INSTALL WITH 2' MINIMUM COVER. CAP AND MARK BOTH ENDS. WATER NOTES: 1. WATER TO BE USED DURING CONSTRUCTION SHALL EITHER HAVE A PERMANENT TAP INSTALLED THROUGH A NEW SERVICE TAP PERMIT, OR A RENTAL OF A HYDRANT METER SHALL BE SECURED TEMPORARILY; THROUGH THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 2. WATER DESIGN 2.1. PUBLIC WATER SYSTEMS SHALL CONFORM TO PUBLIC DISTRIBUTION SYSTEM STANDARDS. 2.2. PRIVATE DISTRIBUTION SYSTEMS SHALL HAVE A MASTER METER AND MASTER BACK FLOW DEVICE. 3. ALL 6" & 8" WATERLINES, SHALL BE DUCTILE IRON PRESSURE CLASS 350 PER CITY OF RALEIGH STANDARDS. ALL 2" WATERLINE SHALL BE TYPE K-COPPER. 4. ALL MAINS SHALL HAVE A MINIMUM 36" COVER. 5. ALL MAINS SHALL HAVE A TYPE 1 LAYING CONDITIONS (GEOTECHNICAL EVALUATION AND COMPACTION REPORTS SHALL BE PROVIDED TO ENGINEER WITH AS -BUILT SUBMITTAL) 6. ALL MAINS SHALL HAVE A WORKING PRESSURE OF 150 PSI AND A SURGE PRESSURE OF 300 PSI. 7. SERVICE CONNECTIONS CAN ONLY BE MADE TO A PRESSURIZED PIPE UP TO 12" PER CORPUD HANDBOOK. 8. REFER TO CORPUD HANDBOOK FOR TESTING AND APPROVAL PROCEDURE PRIOR TO ACCEPTANCE. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI. 10. ALL EXISTING UTILITIES ARE SHOWN AT APPROXIMATE LOCATIONS. CONTRACTOR SHALL VERIFY ACTUAL LOCATION AND DEPTHS IN FIELD PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 �N CARC', .� . =O ; �F ESS ()-7 i J55 :,��, </;tic � NEF:•���,���• 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 PROJECT NOTES Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER SSMH RIM=323.90 12"CLAY(W)=319.47 - SS SS _/ I O O (" 5 O CV O CV N CO I HEREBY CERTIFY THAT THE TOPOGRAPHIC SURVEY SHOWN LEGEND GENERAL NOTES HEREON IS BASED ON AN ACTUAL FIELD SURVEY MADE UNDER 1. THIS IS A SURVEY OF AN EXISTING PARCEL(S) OF LAND. THIS IS A TOPOGRAPHIC AND MY SUPERVISION AND ACCURATELY REPRESENTS THE PHYSICAL 061stalBair%* BOUNDARY SURVEY. FEATURES THEREON AT THE TIME OF THIS SURVEY •** \. CARO��oO EXISTING IRON PIPE ZyflFIRE HYDRANT SD STORM DRAIN PIPE 2. BEARINGS FOR THIS SURVEY ARE BASED ON NC GRID NAD 83(2011). •••��.•••' SS '••/ � 3. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES. ••' ;'pF� /O•. ,y•;L '•� 0 IRON PIPE SET ❑T TELEPHONE PEDESTAL OU OVERHEAD UTILITY LINES 4. ZONING: DX-12-UG-CU PER RALEIGH GIS; CHARACTER OVERLAY: HOD-G; LEGACY OVERLAY: RONALD T. FREDERICK P.L.S. L-4720 �.Q� y� ; QS SANITARY SEWER MANHOLE OT TELEPHONE MANHOLE DOD PER CITY OF RALEIGH ZONING MAP _06/0_1/2020--------------- - i SEAL •. = W WATER LINE 5. AREA BY COORDINATE GEOMETRY. DATE ;•� L-4720 C © SANITARY SEWER CLEANOUT ❑E ELECTRIC BOX SS SANITARY SEWER LINE 6. FLOOD NOTE: THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD HAZARD ZONE. IT IS �0 0;% _Poo V Z LOCATED IN ZONE 'Y' AS DEFINED BY F.E.M.A F.I.R.M COMMUNITY PANEL #3720170300J DATED �• Wv - 0 ��•' •• WATER VALVE LIGHT POLE MAY 2, 2006. •� I %00 SUP, Oo � •• � T TELEPHONE LINE •����j..,6„R,��•••• ® REFER7. UTILITY STATEMENT SHOWN WATER METER `� POWER POLE G GAS LINE 8. THE UNDER ROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION Ii CURB INLET UE UNDERGROUND ELECTRIC AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND Q STORM DRAINAGE MANHOLE UT UNDERGROUND TELEPHONE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES ❑ YARD INLET -X X- FENCE LINE SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 9. THIS SURVEY PERFORMED AND MAP PREPARED WITHOUT BENEFIT OF A TITLE REPORT. THIS SURVEY SUBJECT TO ANY FACTS AND EASEMENTS WHICH MAY BE DISCLOSED BY A FULL AND I I ACCURATE TITLE SEARCH. 10. ELEVATIONS FOR THIS SURVEY ARE BASED ON NAVD 88 BENCH MARK "FIRE HYDRANT TOP NUT" ELEV.= 320.46' I I I N I I I I I II ---------------------------- I I I I I N N I N I N I I I I I GB TOP=318.40 TOP=319.58 to 15"RCP(E)-315.63 15'RCP(E)=316.38 N 15'RCP(W)=315.70 15'RCP(S)=316.74 (Q)15'PVC(W)=316.43 so i GRATE=319.07 N - 15'DI RCP(Nr318.97 N I PIT-7-- ,1 B \ \ O \ SSMH RIM:318.82 12"CLAY(N)=310.D5 12'CLAY(S)-310.03 12"CLAY(W)-313.23 / O N o ' N 1 1 f 30 no ' 68 66 TBM m TOP NU T-320.46 7-7/7 I 1V)/to n n no �\ no 0 0 ° \ no n \ no o no no no -� \ SSMH \ \III\ �3\ GRATE=311.04 DI RIM=314.86 \ \ 15'RCP(N)-308.98 / 6'CLAY(E)=309.59 6'CLAY(W)-309.69 \ \ 15'RCP(S)-308.99 SS E. LENOIR ST. ss \ ss SS SS 66' PUBLIC R/W / / � SS J SS SS SS Znono ° no �° ° �• fTo no n nno n no _nR�� 5.00'_ S 8T34'2T E 210...,TOT.) _ \ m n0 Ov ®o I 131617 i / v1 N GENERAL BAPTIST STATE CONVENTION PIN: 1703763353 603 S. WILMINGTON ST. g D.B. 957, PG. 581 11,0SOFT. I \/ 0.2.25 AC 0 E. � W ►- a o �y 1-STORY BRICK BUILDING 1MTH BASEMENT N I \ I . ,. LIGHT WELL DI FULL OF DEBRIS Ij 105.00' I N ,sue MCDONALDS REAL ESTATE CO N \ PAVED PARKING LOT OPAY PARKING KIOSK J O / +mz67 / GRAVEL PARKING \ \ / LOT OJ x \ I \ x GENERAL BAPTIST STATE CONVENTION NARSI DEVELOPMENT RALEIGH LLC PIN: ✓k PIN:17037814 803 S. wILA11NG. ST. WILMIN TON 112 do 114E 5T. E LENOIR ST. D.B. 1789, PG. 535 I �3 X +3,z so M 25 +31 D.B. 16484, PG.. zse 3,0.0 SOFT. n 7,0.1 SOFT. 0 0.08 AC. n 0.17 AC. X N \ x � 1 i N / PIN: 1703763211 I / 101 E SOUTH ST. I D.B. 14479, PG. 2287 MCDONALDS RNEAL ESTATE CO I / PIN: 1703764221 111 E. SOUTH ST. ID.B. 14479, PG. 2287 N� I I / I I / I fN / I y I I I I N I I I N I I I I N I I I I SS ss ss SS ss ss SS ss DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 I I I � i = o 4 I 3: I IMCDON NIF ALDS RAL ESTATE CO I I PIN: 1703765313 g O 118 E. LENOIR 22. D.B. 14479, PG. 2287 ^ ' o ` V NI I 1 O ill � I I I I I I xl C4 . IL/7) N /MCDONALDS REAL ESTATE CO O PIN: 1703764280 I 1W 17 E. SOUTH ST. D.B. 14479, PG. 2287 O I I = I I I I I This document is the product and exclusive property of I Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed Iwithout the written consent of Duda I Paine Architects, PA. I © Copyright 2020 Duda I Paine Architects, PA I MARK DATE DESCRIPTION I I I I I ISSl1F DATF- 09/10/9090 GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER PROJECT NUMBER: 219011 EXISTING CONDITIONS C1600 Construction Documents I CB FOP=319.58 15"R P(E)=316.38, 15"R4P(S)=316.74 (2)t5"f; jjC(W)=316.43 DI GRATE=319.07 15"RCP(N)=316.97 [EEI Imo' Wv — VAL �W_ — F I I I I N F I I I I F I I I I I I F I I I I F N I I I 1 I F I I I I I I F CBI I I F I TO 318.40 115 CP(E =315.6 I I 015" CP(W =315.7 S'J —7— s II _ EX. OVERHEAD — y I I ®� — POWER MOVE LINES TO BE — I --I— REMOV— — SAWCUT AND — _ — _ REPLACE EXISTING N � \`_ -- —-----_— _ _ / ,T —� ASPHALT PER CITY — -p�-�= — _ _ _ i 7 — — OF RALEIGH _� _�__ M — — — - �\ — — — —=—LPL_=n��� no -�' — _ — o� o — — — — 7 — STANDARD; SEE — — — — — w w — 7_ no — �— ice' — no GRADING PLAN \ EX. POWER METER TO - —w— EX. WATER METER TO \ — — = —=_ FOR PROPOSED BE RELOCATED AS BE REMOVED AND y STORM PIPE TRAF IC SIGNAL BOX AN RETURNED BACK TO \ \ w I CROSSING NECESSARY* III EXISTI G Tw w TRAF IC SIGNAL POLE TO COORDINAYE WITH � THE CITY OF \ �I � \ SATE=311.t�4 _ _ REMA N; PROTECT IN\ — ( \ DUKE ENERGY, RALEIGH; ABANDON Fj. -ENO ST ?CP(N)=308.98 P �— _ A S VICE LATERAL AT u \ \ MAIN ,STREET-P(S),3�8.99 0 L PARKING / EX. FIRE HYDRANT / (66' PUBLI _ \ TO BE REMOVED AND C B TO BE URGROUND ��% — RE OCATED. / R OVED ��5 StRY T,i T,i / ELECTRIC TO / EX. ss= NWEDESTR AN CROSSING / REMAIN; PROTECT POWER LINE TO-BL' EX. WATER METER T SIGNAL/LIGHT POLE AND / o EX. POWER POLE TO IN PLACE / REMOVED BE REMOVED AND — — — = J� REMAIN; ROUND ELECTRIC PLACE TO E BE REMOVED / $� X'POWER POLE 0 RETURNED BACK / REM4YIN; PROTECT IN PL CE OF SAWCUT AN[� __ — — — / BE REMOVED THE CITY � _ — — —_ __ _ RALEIGH; ABA ON _ REPLACE EXISTING /� no — _ = L — — == — —_ _ SERVICE LAT AL A ASPHALT PER CITY ' f — - —/�0 no/� f =gyp — �- MAIOF RALEIGH 1 1 L 4'27" E_ STANDARD ` I I w )— — -f0 — __ _ \ ••� �=-jib le EX. WATE METE TO — I BE REM0 D AN w RaVE S INSIDE 35.00' 70.53' _ I— -I RETURNE BACK IITO I a PROPERTY; ANDON — _ II I THE CITY OF GAS SERVICE IN ROW RALEIGH; ABANDON I u SERVICE LAFR"-AT .L �� _ SOTANDARDSMAIN R�SNC \ �� 1 I A Ld THE WAT RIMAIN \ I EX. P$ING KIOSK I B �OF-WAYIEX. BRICK WALLTO RIGHT IBE REMOVED EX. PROPERTY LINE TO MOVED I\ TO BE ABANDONED EX. OVERHEAD I + \ I III POWER LINES TO BE EX. WATER SERVICE EX. SIGN TO BE F REMOVED rl EX. BOLLARDS TO BE LATERALS TO E REMOVED 1 I I I ��b It \ REMOVED REMOVED ON� I I I I GENERAL BAPTIST STATE CONVE TI N I I PIN:1703763353 I \ EX. ASPHALT PRIVATE SI C�RB TO B II I f I I D.B. 957, PG. 581 II PARKING LOT TO B (o WATER METER TYP.) I I I I I I I /REMOVED II I I A 1/ I 11,011 SQ.FT. ABANDONED x L PA KING LO TO E I I I I I II —i � 0.25 AC 0 v I / A AND NED ❑] I I EX BACKFLOW PREVENTER TO BE o 'Yl x / `+�I I N/F REMOVED; REMOVE WATER 3 RAIL PTISTI NA SI D VELOPMENT RALEIGH o MCDONALDS REAL I� SERVICE LATERAL UNDER TAT E CO ENTION I LLC �I I ESTATE CO I PROPOSED BUILDING FOOTPRINT I I PIN:170 63353� x I PIN 1703764322 & 31 I PIN:1703765313 I I REMOVED LIGHT TO E / I.B. 1789 G. 535 1703764352 I 118 E. LENOIR ST. II I I I EX EX RAILING TO BE I I % 3,66�4 Q.FT. I PG. 2565 � I c, D.B. 14479, PG. 2287 CLEAN(�,1. ND EWER II I ` -�, BUILDING REMOVED N x 0.17 AC. `rI / 0.0 C. A 335 SQ.FT. o ASSO� SERVICIA LATERSEWER01 11� 1 � I I � _ � I // � � � �V ❑ Ili REMOD PER CITY 0 I -EX STORM DRAIN TOI o RALEI STANDARD�I I I BE REMOVED 6y I I I II I I A A � EX. PROPERTY LINE III I I TO BE ABANDONED I# I EXI N 1 v I EX. BUILDING TO BE II I I I I *iIG - W Y r i REMOVED 1 � � I � � � % � � � " EX. VEGEATATION TO \ BE REMOVED �l I I EX. MECHANICAL I I I I /EX. BRIC WALL TO 1 :1 EQUIPMENT TO BE 1 E.A.EX. W�OD FENCE TO II 1 1/ BE iEMO ED Ill I I �L REMOVED I J BE REV I I I ,�I r I 1 SAW CUT CURB AND I — _ — — 105_00_ —` 3 01 I I i GUTTER l — — — — " p7 crz� • ��c Q0,/T�r,�l — — — .— — — Ste. 69W80_ _ —EX:- FENCE IQ aL — — _ — - - I I N / l EX. BRICK VENTS TO REMOVED ------- --------_ - — — --- — --- — — — — I P I I I II I BE REMOVED EX. SANITARY SEWER — — — — — — — — _ — — _ I— CLEANOUT AND J z F II I I I I EX. BLOCKE RETAINING ASSOCIATED SEWER OBI I I I N I SERVICE LATERAL TO BE L-REMOVED REMOVED PER CITY OF I I / T 1 14 I I = — \ RALEIGH STANDARDS N/F L_ I I E-4 a F I I 1� 1 N/F I MCDONALDS REAL I MCDONALDS REAL ESTATE CO J I N/F ESTATE CO PIN:1703764221 I- II I PIN:1703763211 111 E. SOUTH ST. MCDONALDS REAL I I � I I ESTATE CO Q101E. SOUTH ST. D.B. 14479, PG. 2287 PIN:1703764280 a Pal D.B. 14479, PG. 2287 I I 117 E. SOUTH ST. I D.B. 14479, PG. 2287 H�;�� I 1 inz �� 1 I z I I I I I I �I � F I I I I I —M M M M�I — — — — — — — — — — — — — — — — — 3 I EXISTING —M M M M M Ee SOUTH ST M M 3 (66' PUBLIC R/W) SS S!-- SS SS — sS SS — ------- DEMOLITION LEGEND TREE TREE OR OTHER VEGETATION TO BE REMOVED UNDERGROUND UTILITY TO BE REMOVED AREA TO BE REMOVED (SIDEWALK, CURB AND GUTTER, STRUCTURES, ASPHALT, CONCRETE PAVING, ETC.) NOTE: SEE PLAN FOR DETAILED DEMOLITION PROCEDURES, SEQUENCING AND SPECIFICATIONS. DEMOLITION NOTES: 1. CONTRACTOR SHALL COORDINATE WITH UTILITY PROVIDERS FOR THE REMOVAL/RELOCATION OF ALL UTILITIES ON SITE. 2. EXISTING UTILITIES SHOWN FOR DEMOLITION MAY VARY FROM EXISTING CONDITIONS. ATTENTION CONTRA C TORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contactina the Public Works Department at (919) 996-2409. and the Public Utilities Department at (919) 996-4540 at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. Know what's b@IOW. Cal I before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. O O (" 5 O CV O CV N 00 0 GRAPHIC SCALE 0 10 20 40 finch =20ft. SEE SHEET CO.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 ,��Nn n � niiis CARS , f**1'- •„ .� "9 ••- _ y : ��0 3Z4 J-55 IN NOA, J. \4 P5 ,1�1 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 DEMOLITION PLAN C1601 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL i41VAIIs] a:-31210]amnIN2011k'r,TLol99Is]XC3 I I I I I III I �I L_ - ��I' 1 1 1 L - r--------- o, EX. TRAFFIC SIGNAL BOX VARIABLE WIDTH - SIDEWALK ACCESS EX. TRAFFIC EASEMENT 15'X240' SIGHT SIGNAL POLE DISTANCE TRIANGLE G dams - ___ LIGHT (TYP.) RIGHTINOF-WAY jUNDERGROUND ---- �- to ELECTRICAL �j EX. ABOVE GRADE BOX ® m ELECTRICAL BOX/METER; 16' COORDINATE WITH DUKE STREETSCAPE ENERGY FOR RELOCATION � CITY OF RALEIGH No, ADA RAMP TYPE N - -- N-3A (SEE DETAILI R10' 178.4' �\ SHEET C-8.01) • \ ■ S 87° 4'27" E ao 1 I EX. PEDESTRIAN / SIGNAL C OSSING - r 16' TREETSCAPE 3.2' R CUR (TYP) I I I N - I I VARIABLE WIDTH 0 CD SIDEWALK ACCES (EASEMENT N Z PAVER AREA; PRIMARY SEE ENHANCED " I I ENTRANCE HARDSCAPE PLANS BUILDING PRIMARY 115'x2O' TRAN IT OVERHANG ENTRANCE ZONE REQUIR D I ALONG WILMINGTON I I I I ST (Z-42-14� #6) 6'x10' BUS P APPROXIMATII N I LOCATION 15.9' I AM NITY WIDT - 65.9' w I Z 34.8' B-B o o METAL GRATE CITY OF RALEIGH I I `41. I I I ABOVE UNDER I WATER EASEM NT I -' GROUND TRANSFORMER 1 I Im VAULT 1 t Z/ r - - - - EXISTING E. LENOIR ST MAIN STREET, PARALLEL PARKING - ------ (66' PUBLIC- -R/iry- 6" GRANITE 4' WIDE TREE (PRIMARY STREET) CURB (TYP.) GRATE (TYP.) TRANSITION TO FLUSH CURB HATCH DENOTES FLUSH CURB O R5' 26' BUILDING 0-20' -up BUILD -TO LINE SHORT-TERM °IP BICYCLE PARKING 1 (2) BIKE RACK (4) SPACES BUILDING 182,917 SF I 12' I 1 I I I 2 II II II � II II I I I I II L - -- / I I 15'X280' SIGHT DISTANCE TRIANGLE SEE DRIVEWAY /SIDEWALK DETAIL ON SHEET C8.00 ------ - TRANSITION TO FLUSH CURB R2' R3' � I EXISTING RIGHT-OF-WAY I CROSSWALK I (TYP.) HATCH DENOTES FLUSH CURB PAVEMENT MARKING I S. WILMINGTON STREET SECTION I I I AVENUE 4-LANE PARALLEL PARKING I I I MCDONALDS REAL ESTATE CO PIN:1703765313 I 12' 118 E. LENOIR ST. I I J I I D.B. 14479, PG. 2287 I F i EXIS NG 15. I I UNDERGROUND I I / , ,� PRIVATE DRAINAGE I I RIGH -OF WAY - -- I - I TRANSFORMER, SEE I / I I I lav I BMPEACCESS &RMWATER I I ARCHITECTURAL T-T-7Tt-r 1 PLANS (TYP.) I I I I MAINTENANCE) I I III I I I I I I I I I i111 ( I I I I 11 TIE IN CURB I -_ TO EXISTING II /%- - _ _ _ -�� 90'(TOTAI '! I TRASH AND---------- I - I EX. IGHTPOLE II I < I III SURFACE METAL RECYCLING ____- - - - - - -- - - - - - - - _ _ I� GRATE ABOVE UNDERGROUND GENERATOR/ELECTRICAL - J Z-'I TRANSFORMER II I I I I ROOM I15Q41 0' SIGHT L L_ - VAULT I PRIVATE DRAINAGE DI NCE TRAINGLEI I - - N/F EASEMENT (STORMWATEI� MCDONALDS REAL BMP ACCESS & I I I E-;0,1 II \ )f I MCDONALDS REAL ESTATE U) r-al^ I I ESTATE CO PIN 17037640221 MAINTENANCE) I N/F MCDONALDS REAL ~I I H II I D.B.144 9, PG. 2287 PIN:1703763211 ESTATE CO Z �W I I I 101 E. SOUTH ST. I PIN:1703764280 � � Ix w II D.B. 14479, Pc. 2287 I EXISTING 117 E. SOUTH ST. I I Z U I I D.B. 14479, PG. 2287 I CBUILDING j Za'M� I I P Q j I I I I I zI I I � I I I I II I I I I / I I EXISTING E. SOUTH ST (66' PUBLIC R/W) I -- I I I I I I I I I I , I I I I I I l I I I I I I I I I � I / I I I I I I I I � P. al CD CD M CD N CD N N 1 00 SITE PLAN NOTES 1. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 50' OF ALL MINOR RESIDENTIAL, RESIDENTIAL, AND RESIDENTIAL COLLECTOR INTERSECTIONS. 2. WITHIN THE AREA OF ABOVE DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMS, OR PARKED VEHICLES BETWEEN THE HEIGHTS OF 24 INCHES AND EIGHT FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVELED WAY IF NO CURBING EXISTS. 3. MULTIWAY STOP CONTROL WILL NOT BE USED AT ANY PUBLIC STREET INTERSECTION WITHOUT THE EXPRESS, WRITTEN CONSENT OF THE CITY TRAFFIC ENGINEER. 4. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS. 5. ALL DIMENSIONS SHOWN ON SITE PLAN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 6. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 7. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO THE SUBSTITUTION OF ALTERNATE EQUIPMENT. 8. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 9. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION OR TO THE SATISFACTION OF THE OWNER BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 10. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. THESE SOILS SHALL BE COMPACTED TO STANDARD PROCTOR MAXIMUM DRY DENSITY OR AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 11. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 12. CONTRACTOR SHALL NOTIFY "NC 811" (811 OR 800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC 811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 13. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 14. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 15. PRIOR TO STARTING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL HOLD A PRE -CONSTRUCTION CONFERENCE WITH CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT FOR EROSION CONTROL AND ENGINEERING INSPECTIONS PRIOR TO ANY WATER OR SEWER ABANDONMENT, REMOVAL OR INSTALLATIONS. 16. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 17. PARKING DECK WILL NOT BE VISIBLE FROM THE STREET. SEE ARCHITECTURE PLANS FOR LAYOUT. 18. STREET TREES LOCATED WITHIN SIGHT DISTANCE TRIANGLES SHALL BE LIMBED TO A MINIMUM OF 8 FEET ABOVE FINISHED GRADE. 19. SIGHT DISTANCE TRIANGLES ARE MEASURED FROM EDGE OF NEAREST TRAVEL LANE TO ACCOUNT FOR ON -STREET PARKING/LOADING. EX. RIGHT-OF-WAY EX. RIGHT-OF-WAY TO REMAIN IN TO REMAIN IN WILLIAM CHRISTMAS WILLIAM CHRISTMAS PLAN DISTRICT PLAN DISTRICT p 122' PUBLIC RAN p 16' 90, B-B 16' (MIN.) (MIN.) z 10' 6' 8.5' 6' 11' 11' 17' 11 11 6' 85' 6' 1 10, z 9 (MIN.) (MIN.) PARKING PARKING (MIN.) (MEN.) o 25' Q�il 1l 0 0 WIDTH F VARIES a 5 1,4' 1Fi a l� 4" IFT WIDTH y4" IPT ,ra• IFT VA R E S 0 b m 0 ay �hf GENERAL PAVEMENT DESIGN 1 � m c b CGS t* 0 � 3" S95B A j z m C- 3" 119.0B B° ABC � y WALKWAY TYPE SIDEWALK PLANTING TYPE TREE GRATE !LAWN TREE SPACING 40' O.C. AVG. PARKING TYPE PARALLEL ON 2 SIDES E. LENOIR STREET SECTION SITE LEGEND 0 SIGNAGE T YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW ACC ACCESSIBLE PARKING STALL VAN VAN ACCESSIBLE PARKING STALL XX, PARKING SPACE COUNT ACCESSIBLE RAMPS TYPE AZ) TYPE © TYPE ANGLED PARKING 96' PUBLIC RIW 16' 64' S-S 16, 10, 6' 2.5 17.5' 12' 12' 17.5' 2.5' 6' 10' PARKING PARKING GRATES GRATES 1 GRADE POINT EX. RIGHT-OF-WAY TO REMAIN IN PARALLEL PARKING WILLIAM CHRISTMAS 9 PLAN DISTRICT 73' PUBLIC R(VV 16' 41' B-B 1fi' 10, 6' 8.5' 12' 12' 85, 6' 10' PARKING PARKING TREE GRATE 2:5' 2.5' TREE GRATES GRADE s m z POINT WIDTH �y VARIES m � 0 z G r PAVEMENT DESIGN 0 A > r r n 3" S9.SB 3" 119.0B 8" ABC GENERAL WALKWAY TYPE SIDEWALK ON 251DES PLANTING TYPE TREE GRATESILAWN TREE SPACING 40' O.C. AVG PARKING TYPE PARALLELI60° ANGLED Know what's below. Cal I before you dig. P GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. CONTRACTOR SHALL NOTIFY "NC81111 (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC81111. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 �N CARS, '� 9 O ES`i � 4 155 • ACCESSIBLE ROUTE .li�ll�ll�ll�ll. PHASE LINE - - PROPERTY LINE - - - RIGHT-OF-WAY LINE _ - - - - LOT LINE - - EASEMENT LINE CENTERLINE HEAVY DUTY O ASPHALT PAVEMENT a a CONCRETE a PAVER OUTDOOR AMENITY AREA LEGEND AMENITY AREA SITE AREA = 22,009 SF REQUIRED AMENITY AREA = 2,450 SF • 10% OF SITE AREA = 2,200 SF +50 SF PER EACH FLOOR ABOVE 7 STORIES = 250 SF PROVIDED AMENITY AREA = 2,484 SF SEE SHEET CO.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER CN N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION SITE PLAN C goo Construction Documents VARIABLE WIC ACCESS EASE 15'x2O' TRANSIT ZONE F ALONG WILMINGTON ST ( 6'x10' BUS ST01 APPROXIMATION EXISTING RIGHT —OF TIE IN i GUTTER EX. LIGHTPOLE II I II I I II II I I I� I--------- I� I II I i I I II I Know what's below. Cal I before you dig. P. 01 CD CD M CD N CD N N 00 CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. I L� EXISTING E. LENOIR ST MAIN STREET, PARALLEL PARKING -------------I------------- I I I I I I N GRAPHIC SCALE 0 5 10 20 1 inch = 10 ft. SEE SHEET CO.01 FOR ALL PROJECT, SITE, HARDSCAPE NOTE: GRADING, STORM DRAINAGE, AND UTILITY NOTES HARDSCAPE MATERIALS AND INSTALLATION TO ADHERE ALL CONSTRUCTION SHALL CONFORM WITH THE TO CITY OF RALEIGH STANDARD. LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. -J66 PUBLIC --R/W)-- (PRIMARY STREET) SITE LEGEND ,��y =� � TYPE AQ TYPE © TYPE QC 0 0 0 � I I SIGNAGE YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE RAMPS PROPERTY LINE RIGHT—OF—WAY LINE EASEMENT LINE CENTERLINE CONCRETE HEAVY DUTY ASPHALT PAVER I EXISTING RIGHT—OF—WAY I I I I I I I I I I I I I I SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 A 01 LU ITCrT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 W O 2 N N O .�����N CAR(,, pF ��4 9 0 75 355 - ;; tir; NEB,. ",loll I115111"0. n— nW1 W � ' — O v O N U �z E� v I C`7 � O 1%%O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA I MARK I DATE I DESCRIPTION I STREET HARDSCAPE PLAN C 601 Construction Documents F � / I I I F V) I I I I CB CB F TOP=318.40 TOP=319.58 � 15"R P(E)=316.3 15" CP(E)=315.6 15W _315.7 15"RC}P(S)=316.74 r - rt2�JY5" C(W)=316.43 SDI DI S GRATE=319.07 \ 15"RCP(N)=316.97 \ LJ N/ ( I `-- i\ TIE STORM INTO CI-) T---------_------`- - - - - - / - - - - - - - - - - EXISTING STORM / STRUCTURE / n w\� o w -\- w w�-w � \ n--no - - - �no no w \ =SSMH w w w w ww_ w wR�M14.86w DI \ \ \ 6 "CLAY(W) 309.69 � \ \ 1�S! NG CRATE=311.04\ / -w w w _ A E. 15"RCP(N)=308.98 _ NOIR ST 5„RCP(S) $ 99 SSMH / � - - - \ - \ � v MAIN STREET, - PARALLEL PARING --------- -- (66'12"CL )=310.05 EXISTING VARIABLE WIDTH SIDEWALK / 2� -- - ---- RIGHT- F-WAY / 5 I j / (PRIMARY STREET) \ 9 -- SS 12"CLAY(S)=310.03 / GV ACCESS/EASEMENT / \ / I2 LF 12" ET ��� d� 12' LAY(W)=313.23 / I / r 19 LF/12" HDPE / /� 0 102 LF 12' HDPE � 3�' � � \VARIABLE WIDTH f/ -\ 7% \ 1.08% \ /i CS 2.90% \ SIDEWALK ACCES ai � a1 a� STCO-200 � 61 LF 15" RCP EASEMENT i � 01 a m o o1 /o ® 1.08% Jill f an 1 � JB-101 - - an 87' 4' 7" E AD-20 0 312 2 - /�� \ 210.53 T TAL)-sZ---- lani El I I f A0=262 El- I -- - ---- - --- ---- - - - - - - - --- y / LD � _ _ I � PR=312.20 LullI - _ _I _ 315.50- \ - NORTH PLANE - 9 \ L-N&E AM , O I \ - - _ - - EX=31 .45 - / c� \ 0-20' J tO o 3i 7.45 INTERNAL RAMP 315.50►� \ BUILD -TO LINE oP Q I L-N&E -z EX=317.36 \ II ! eP� I I I72 I H-N&W II \\ SER SHEET GRADES I I ® 1LOF41� " RCP ► I I �/ I I PR-317.38 I \ Z H-N&W BUILDING / I I VARIABLE WIDTH PRIVATE Z c / ► I i i I / / N /� II/ /a II\V I I IIJ DRAINAGE EASEMENT 6 N=35.50 3,S.So lo I (STORMWATER BMP f f ACCESS &MAINTENAMAINTENANCE) oo Iai 0o VARIABLE WIDT I MCDONALDS REAL I 0 LIMITS OF 6 317.25 PRIVATE DRAINAGE I I I w P ESTATE CO I I DISTURBANCE I I I I I EASEMENT�STOZ PIN:1703765313 \ I I I a I I 118 E. LENOIR ST. I L J M ICCESS NTENANCE) I I I D.B. 14479, PG. 2287 ► I I I �I ► w Q h LIMITS OF ► / \ o DISTURBANCE - u I EX. RONI / I / I I I I I 316.80 NF�\al L 111J J I CONNECT TO INTERNAL \ ISF-IN �JB-102 I/ ROOF DRAINAGE 316.80 I / COORDINATE/ WITH PLUMBING FLANS \ 11 LF 15' RCP i ❑ _ I v �® 1.49% tl I to ► I- I I // s I i I V I SF-ciT I/ III I l l j FFE=316.80 I I III I I 141 I I I I I I I I EX=315.98 / ��r- I I { I I ► �`I I I III I I I I L-W I I' F/ o L 1111.J H-S / 312 .k -- - - TH PLANE - - J / I I I TSCD- C - - - - i R7'4, z'77"- q� I - n�f'1 %(1 TT I I I I i /� LD LD PR=316.20/ - - - - - - - - FF I I H-S LD LD - - LD LD - - - - - L - - - - 0 co� III - L-W�/ / _ - _ _ UNDERGROUND STORM CD LD D L J PRS312.50 I / I I I I Z I I I I I FILTER VAULT I H_E 1( I I l I RIM=MATCH FINISHED GRADE / I OF PARKING DECK _ - - - _ Ex=312.50 / fi I I II I I �_ _ _ - \ / \ 15" RCP (OUT)=310.56 N/F / I H-E ► / I I I I �� I / N/F \ 12" RCP (IN)=312.56 MCDONALDS TA ECO EAL I / MCDONALDSESTATE \ ESTATE CO r J / ► N/F Cl)- I ���^ I --- - _ _ �Jl \ MCDONALDS REAL I I --I IyI'� r / PIN:1703763211 ► v 111 E. SOUTH ST. I / ESTATE CO � - II I I / 101 E. SOUTH ST. I D.B. 14479, PG. 2287 I / I PIN:1703764280 a+ II I / D.B. 14479, PG. 2287 �% 117 E. SOUTH I 22 I I I ' D.B. 14479, PG. 2287 �z1.4 I�� ► I II ► I � w�Wia I / I I � I I I �ICID� I / ► - ----J I I \ I I I I � zl � I ► I �/ I �V � I I /1 I I II - -I / I � I i I / i I -M-M ---'T- - - - - - - ---- - 3 j-M M � M M M \ 3 M M t'-�I}I RIM=3S4.63 En_ EXISTING i M M M M M M M 12"CLAY(N)=305.83 E. SOUTH ST 12"CLAY(E)=304.99 3 -(66' PUBLIC R/W) i SS SS -------- i -- --- �s - SS SS - - _ � � SS SS SS SS /„ SS SS SS - SS 0 GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. P. al CD CD M Lf) CD N CD N N 1 00 CIO FLARED END SECTION U ENDWALL SECTION CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN O JUNCTION BOX DRAINAGE FLOW ARROW ti LINE BREAK SYMBOL 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION + 250.60-MG MATCH EXISTING GRADE STORM DRAINAGE STORM SERVICE LINE RD RD RD ROOF DRAIN, 8" ADS NON -PERFORATED TUBING OR EQUAL 1.0% MIN. SLOPE 3' MIN. COVER PVC SCHEDULE 40 IN TRAFFIC AREAS TP TP TP TREE PROTECTION FENCE LD LD LIMITS OF DISTURBANCE WOODED AREA 250 MAJOR CONTOUR 252 MINOR CONTOUR ------ 250------- EXISTING MAJOR CONTOUR -- ----- 252------- EXISTING MINOR CONTOUR - - EASEMENT LINE ACCESSIBLE PARKING AREA (2% MAX. SLOPE IN ALL DIRECTIONS) STORM STRUCTURE SCHEDULE: EX-CB100 T/C=31 1.54 INV IN=308.99 (JB-101) JB-101 RIM=312.27 INV IN=309.65 (JB-102) INV IN=309.65 (STCO-200) INV OUT=309.65 SF -OUT INV=310.56 SF -IN MATCH FINISHED GRADE INV IN=312.56 JB-102 MATCH FINISHED GRADE INV IN=310.40 (SF -OUT) INV OUT=310.40 STCO-200 RIM=312.62 INV IN=310.00 (AD-201) INV OUT=310.00 AD-201 T/G=316.17 INV IN=311.20 (AD-202) INV OUT=311.10 AD-202 T/G=315.30 INV OUT=311.40 Know what's below. Call before you dig. GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT, THE ENGINEER AND A REPRESENTATIVE OF THE OWNER. 6. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 7. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 8. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES 1. ALL STORM DRAINAGE PIPES SHOWN SHALL BE CLASS III REINFORCED CONCRETE (RCP) UNLESS NOTED OTHERWISE. 2. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH STANDARDS. 3. ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4 ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 5. ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 6. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD, USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 7. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 8. MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE OR GEOTECH AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 9. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95 % OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8)INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 11. ALL CONCRETE PIPE AND PRECAST STORM STRUCTURES SHALL MEET NCDOT STANDARDS AND STAMPED ACCORDINGLY BY MANUFACTURER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL PIPE AND STRUCTURES FOR CRACKS OR BREAKS, PRIOR TO INSTALLATION. ANY DAMAGED ITEMS SHALL NOT BE INSTALLED. 13. "KNOCK -OUT" BOXES OR HDPE PIPE SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAYS UNLESS APPROVED IN WRITING BY CITY OF RALEIGH STORMWATER DEPARTMENT. AVERAGE GRADE DETERMINATION: EXISTING PROPOSED HIGH LOW AVERAGE HIGH LOW AVERAGE NORTH PLANE 317.36 312.45 314.91 317.38 312.20 314.79 WEST PLANE 317.36 315.98 316.67 317.38 316.20 316.79 SOUTH PLANE 315.98 312.50 314.24 316.20 312.50 314.35 EAST PLANE 312.50 312.45 312.48 312.50 312.45 312.48 BUILDING 1 AVERAGE OF WALL PLANES 314.57 314.60 MOST RESTRICTIVE CONDITION OCCURS IN THE EXISTING CONDITIONS WITH AN AVERAGE GRADE OF 314.57'. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. DISTURBED AREA = 0.70 AC. SEE SHEET CO.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 CARD, 03�J55 N O 2 N N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION GRADING &STORM DRAINAGE PLAN C3e00 Construction Documents I U, / T-------------------- - - - - - - - - - - - - - - - - - -- -T -- \-T----- / 1--- - - - - - - - _ I =--------- -�° _- na nno-------------/-_-J- ----�-� - - - - - - - - - -------- --_ - / 7 -- �- no no no no no - - no no �il:� o - - / - - - - - - rrN� w w w w n0-ono- no noc- 1--------T------ - \ -� w w w w----=-f===�= T�- -__�_° _ no no no _- ----- W \� T w w w wow w- \� o`"---_- n�� -no_� no - no �� \ SSMH -w w w w w \ w w w w �� w w - y -� w w w w \ EX-C6100 N � \ `RIM=314.86 � w ' � ��\ w � � EXIST \ /v I F \ 6 CLAY(E)�309.59 EXISTING = D� � v 6"CLAY W =30-.69 � �� � � � CRATE 311.04� � I \ � ( ) �� � . .1:� 15"RCP�f�)=308.98 / 0IR ST / -- - - - - - -- --\ = ----- - -- _ MAIN STREET EIN P15"RCP (S) =�� 8. 9 9 s s / r _ r ARALLEL PARKING / / '��/ �/Oi - _ ss- » � � t --- -�66 ---PUBLIC R _w- -- --- N � F , / '�/ / � I -�- S�-� =,Z--sue- - - ---- - I I I I GRADING LEGEND m FLARED END SECTION U ENDWALL SECTION CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN Q JUNCTION BOX DRAINAGE FLOW ARROW r.. LINE BREAK SYMBOL 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS /317.36 (PRIMARY.STREET)I �TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION 316.86-MG � J >>> / / (NOTE: BOTTOM OF WALL IS GROUND ai an / / ��� ELEVATION NOT WALL FOUNDATION) /F / 311.42 MG f / / o 1/1 ADJUST EX. MANHOLE RIM i 61 LF 15" RCP o 1 /r 317.27 r I / 19 LF 12" HDF£ o / WW W TO FINISHED GRADE i @ 1 08% + 250.60 SPOT ELEVATION 317.36 / o 0 1.07% / >>> i N I / 317.36 316.77- L _o / 316.18 / / / / + 250.60-MG MATCH EXISTING GRADE °1 L_ m o ai 315.68-MG I / / 31 1.97-MG 317.68 °1 ai al / I I S 311.75 a-i 01 0 � o !- I i 9 STORM DRAINAGE m i 311.25 I 317.18 MG 01 a� J-..�� � �,, � 312.83 312.48 � m on STORM SERVICE LINE N ( I' m m a,312.33-cG m 311.98-MG 311.42 ' f - a . 01 °1 a� y -_ 311.42 ROOF DRAIN, 8" ADS I a - - �J� -- -- - - -- -- - 0 - o - o- - RD- RD- RD- i � � O � 1 NON -PERFORATED TUBING OR I / 317 27 a S 87° , „ \ v �� L - EQUAL 1.0% MIN. SLOPE 3' MIN. F - - _ _ 4 2 7 E A"O1 �'� \ 4 I O T 1 3j2 �2 9 �, COVER PVC SCHEDULE 40 IN ' I \ 210.53 (TOTAL _ 102 F 12" HDPE I - TRAFFIC AREAS I \ 317.62 VARIABLE WIDTH SIDEWA - �� 1' 8% i'� 312.43 3 - --TP-TP-TP- TREE PROTECTION FENCE 317.12-M6 �� 317.37 ACCESS EASEMENT �O V 13 LF 312.43 311.54 ti - JB m ] v - - _ ❑ \ (F � - - 1 1.54 LD LD LIMITS OF DISTURBANCE an 31727 AD-202 v \ [j3�1 a- - ---- -- -- - - - - - - -_L- - --❑- - -- r- -C'0 -200� ---------- 3[1 i I\I I9II2 - -0-- \ - - - - WOODED AREA - - - - - - - - - - - - - - BS 12.62 312.49 ---------31339g31.0250 MAJOR CONTOU R IE 252 -- 315.48 - MINOR CONTOUR T3 EXISTING T SPS 250 RIGHT-OF-WAY I I ______--- MAJOREXISTING /LLJ 315.8 o R P 312.81 317.38 313.39 312.31 312.74 II(XI _____252 _EXISTING MINOR CONTOUR I 312.24 c, 3 3.9 312.56 EASEMENT LINE314.65 No u' 020' 314.65 -RAMUP I INTERNAL RAMP \315.50 BUILD -TO LINB ACCESSIBLE PARKING AREA LO (2% MAX. SLOPE IN ALL DIRECTIONS) I NIO 1317.45 I \ UP T-I OF / DIM�TURBANCE 317 1317.14-M('w \ 13� A 315.45 I' BUILDING --- I FFE=315.50 / � 72 LF 15" RCP c, / / 1 I I / z 0 1.04% I i �� 315.50 I / - - � (I4)-SLEEVES hN CURB o o I I 19 UTLETS FOR/ 4" PVC o I I h I __ VAR' BLE WI TH PRIVATE I RAIN PIPES - - J m \ __ _DR7 AGE E SEMENT I I / '� I I I- / (STO MWAT R B I I I I I I SS & AINTENAN E) 317.1 I 19 n 6 / INV.=316.18 ICI I I / INV.=316.17 I 317.25 (4)-4" PVC DRAIN PIPES I / 1 ® 1.0% MIN. SLOPE FOR BACKFLOW PREVENTER INV.-316.1 6 EMERGENCY OVERFLOW INV.=316015 LD INV.=316.50 / \ I I I III to I I I FFE=316.80 o I I I 1 I I 1 I \ / ROW I 316.70 \ o I I I N II II II II / I / � 316.58 \ I I \ r----------- I X I 9 � / � I,l \ 1 I I I 316.80 // \ I VARIABLE WIDTH PRIVATE cr) I I I DRAINAGE EASEMENT I I I I \I 11 I I IV I I� I I (STORMWATER BMP ACCESS AND I LIMITS OF316.48 ram MAINTENANCE) DISTURBAN CE T11, _JI__I__L 8F-w I III I J I11 316.80 I I I / 1316.23 I 1 \ �- CONNECT\TO'INTERNAL 315.73 M j 1 U ROOF DRAINAGE COORDINATE WITH JB-102 I I I I PLUMBING PLANS _ I i 16.80 / - / \ ®1191 RCP I_1 FFE=316.80 \ SF -OUT I I I I I I I I I I 1 31 .54 I I I I I I I I 315.8 316.12 I I I I / � I I 315.3 -MG 316.05-1-_J__I___j 31 .44 _ UNDERGROUND STORM 1 �I I9 �_L � I I FILTER VAULT hn RIM=MATCH FINISHEDI GRADE I Ir ) I I I I OF PARKING DECK I x I I I I I I II I 316.10 i\ SEE DETAIL ON SHEET C9.00 s ----- _ 31 6.20-MG L� _ I I - - - -X-X-X-xX����f7 �X87 �(�_L"� ��T��I� LD--- --- ------ - LD 315.95-MGLD LD J / - LD -- L°-- �� --LD --- - - _--------- i I I DISTURBED AREA =0.70AC. I1 i I �-316.00-MG // /// LD LDLD LD LD LD - LD --� ---�- - - - - - - - - - - - - - - - - __ __ I � / �j I I I- - / � TEMPORARY CONSTRUCTION �- � LD LD LD LD � - - - - - � 9 CD/ I 11 "t" I I I I 1 - - - - -- -- EASEMENT I LD LD � LD - SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT, THE ENGINEER AND A REPRESENTATIVE OF THE OWNER. 6. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 7. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY GRAPHIC SCALE DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 0 5 10 20 8. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. linch =loft. P. 7 CD CD M Lf) CD N CD N N 00 Know what's below. Call before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 N O 2 N N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION DETAILED GRADING PLAN C 601 Construction Documents I I I I N E I I I I IF I I I I F I I I f I I I II F o N I I®® L__ _ - - - - - -1- TR /' I L ��� T�-------------------------- wv / \ I - - - -WV_ N WV = _ _ _ -------------------� -yy V-----__ -=n0 =_ no �_T_ RELOCATE POWER SSMH w w w w " � EX. 12" CIP W/L _w N METER SSMH 6"CLAY(E)=309.59 EX.SSMH-100 ��� EXISTING w w w w- 4.86 NIV IN, 309.79 ($$MH-101) E. LENOIR ST f 6"CLAY(W)=309.69 - MAIN STREET, PARALLEL PARKING SSMH EX. LIGHT (TYP.) STREET LIGHT; EX. 6" CLAY SS // RIM=318.82 VARIABLE WIDTH 30' GREY FIBERGLASS s� l66 PUBLIC R/W) - ss - 12"CLAY(N)=310.05 rn J'- SIDEWALK ACCESS POLES WITH LED ROADWAY (PRIMARY STREET 12"CLAY(S)=310.03 \I EASEMENT ) 12"CLAY(W)=313.23 } 3 FIXTURES (TYP.) a pd COORDINATE WITH DUKE 35 LF 6" PVC ENERGY AND OWNER 0 1.32% Co I EXISTING \\ XU) �I o o RIGHT-OF-WAY WN W \ FIRE HYDRANT - - S 87° 4'27" E O - (, 1 JASSEMBL4 210.53 TOTAL /---- --------------------- - - �❑ - ❑ ❑ ----- o _ I I 16"X6" TS&V r - - _ SSMH-101 --- ------+--- wll - STA_-INV OGP RD=314.80 - --- _ I ;4 o l j INV OUT=310.25 1--- VARIABLE WIDTH (0 I j ACCESS BUILD -TO LINE ~uP SIDEWALK O -N I I I (1) 4" SEWER EASEMENT z 1) 3" SEWER HOSE BIB; SEE SEE PLUMBING PLAN FOR PLUMBING PLANS FOR WALL CONTINUATION I I I I MOUNTED II I Z CONTINUATION BUILDING PIVFFE 315.50 6" DIP FIRE II oIo I I I N i 6" RPDA BACKFLOW PREVENTER LOCATED SERVICE LINE II INSIDE BUILDING (AMES 5000 CIV OR El 00 APPROVED) 6" X4" DIP TEE I I Im o 3 - I I I I 6"X6" TS&V I i N II I I I 4" DIP 90' BEND I ❑ N 4� DOMESTIC METER RISER 4" RPZ BACKFLOW PREVENTER LOCATED I I I I (ROOM INSIDE BUILDING (AMES 4000 CIV OR SEE PLUMBING 1 APPROVED EQUAL) PLANS FOR CITY OF RALEIGH 7- WATER EASEMENT 1�1L +1 i I CONTINUATION I I I I 14" DIP DOMESTIC -T_7�= I J ❑E i I SERVICE LINE E-ram I I EXISTING I I I I RIGHT-OF-WAY III I l t l j I II I 141 I YARD FDC ill ii I I I 6" DIP SANITARY I I I 1 SEWER SERVICE _ 2.7.....(1'(T(IT /�I i EXTENDS OF UNDERGROUND TRANSFORMER VAULT II 1,500-GALLON GREASE - - i- ' I INTERCEPTOR WITH II II -t----------------------------- TRAFFIC -RATED TOP Z f II I I I TRANSFORMER IN L - - - UNDERGROUND VAULT I I N/F I N/F I MCDONALDS REAL MCDONALDS REAL ESTATE CO I COESTATE PIN:1703764221 II J / PIN: 703763211 I D.11114E.479 TH T. E,1 O �AQ I I 1. E. SOUTH ST. D.B. 14479, PG. 2287 I �I I z� E E0 I I �z I w�Wa I I I I I � CIOa I I I I _ no -'Kno no - -w w w W w OJ ss - SS Ss - OJ GAS SERVICE LINE TAP; / COORDINATE WITH LOCAL UTILITY COMPANY -� � -J GAS METER AND SERVICE LINE, SEE PLUMBING PLANS FOR CONTINUATION II I I � I I I III III N/F I MCDONALDS REAL I I ESTATE CO I PIN:1703765313 118 E. LENOIR ST. I c, II I I I� III I� D.B. 14479, PG. 2287 I I I� I� I II I� II I I N/F I MCDONALDS REAL ESTATE CO PIN:1703764280 117 E. SOUTH ST. I D.B. 14479, PG. 2287 ICl) rA I Iz I I I N I I I N F I I I I -M�M---------------- 3 3 -M M M M SSMH M M RIM=314.63 N EXISTING M M M M M M 12"CLAY(N)=305.83 E. SOUTH ST 12"CLAY(E)=304.99 3 (66' PUBLIC R/W) SS SS - - ss ss SS SS ss ss ys SS ss ss P. 01 CD CD M CD N CD N N 00 I I I I - - J UTILITY LEGEND FIRE HYDRANT ASSEMBLY FIRE DEPARTMENT CONNECTION (FDC) WATER METER N WATER VALVE N POST INDICATOR VALVE ® VALVE IN MANHOLE ❑ METER & VAULT © BACKFLOW PREVENTER REDUCER PLUG o-11111 BLOW -OFF ASSEMBLY • SANITARY SEWER MANHOLE • SEWER CLEAN -OUT m GREASE TRAP SEWER FLOW DIRECTION / ARROW YARD LIGHTS LIGHT POLE POWER POLE ..� LINE BREAK SYMBOL WATERLINE WATER SERVICE LINE ----------------- UTILITY SLEEVE SANITARY SEWER SEWER SERVICE LINE FM FM SEWER FORCE MAIN -G000 GAS LINE OU OU OVERHEAD UTILITY UE UE UNDERGROUND ELECTRIC -TTTT TELEPHONE - - EASEMENT LINE Know what's below. Cal I before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. CITY OF RALEIGH PUBLIC UTILITIES STANDARD UTILITY NOTES (AS AP P LI CAB LEA 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS, DETAILS & SPECIFICATIONS (REFERENCE: CORPUD HANDBOOK, CURRENT EDITION). 2. UTILITY SEPARATION REQUIREMENTS: a) A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. b) WHEN INSTALLING WATER &/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER & MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. c) WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. d) 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER & STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. e) MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN & RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER & RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS & A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (PER CORPUD DETAILS W-41 & S-49). f) ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS & SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL REUSE MAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER & SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. THIS INCLUDES ABANDONING TAP AT MAIN & REMOVAL OF SERVICE FROM ROW OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. INSTALL 6" DIP WATER SERVICES WITH METERS LOCATED AT ROW OR WITHIN A 3'X3' WATERLINE EASEMENT IMMEDIATELY ADJACENT. 8. INSTALL 8" PVC* SEWER SERVICES ® 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SANITARY SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0' ABOVE THE NEXT UPSTREAM MANHOLE. 10. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 11. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. 12. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX-B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HARTLEY AT (919) 996-5923 OR JOANIE.HARTLEY®RALEIGHNC.GOV FOR MORE INFORMATION. GENERAL NOTES 1. ALL REQUIREMENTS FOR FIRE SAFETY PER CHAPTER 14 OF THE 2012 NC FIRE CODE AND CHAPTER 33 OF THE 2012 NC BUILDING CODE ARE TO BE MET THROUGHOUT THE DURATION OF DEMOLITION AND CONSTRUCTION. 2. THE OWNER SHALL PROVIDE SECURITY AND REASONABLE SURVEILLANCE FOR THE PERIOD DURING CONSTRUCTION OF THE PROJECT WHERE THE WOOD FRAME STRUCTURE OF THE BUILDING IS EXPOSED TO THE ELEMENTS. 3. PER 2018 NCBC SECTION 403.3.3, A SECONDARY WATER SUPPLY IS REQUIRED FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E, OR F. PROJECT IS LOCATED WITHIN SEISMIC DESIGN CATEGORY B AND THEREFORE A SECONDARY WATER SUPPLY IS NOT REQUIRED. 0 GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. SEE SHEET CO.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 A 1113rL11TCrT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 N O 2 N N O 4- �1 ' � O ^ v ) O N MU� V/ .0 Z E .M O 1%%0 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA I MARK I DATE I DESCRIPTION I UTILITY PLAN C4.00 Construction Documents - =_ =_-___--------------_ --- ---- ------ --- - --- -- no / -�------ T\ � no no no no T no � J no no � — — 7 � — r _ rN w w w \ \\ 3-----T=====_--____ —no—ono— no aoo �—--------- ----- —mow w w w w w �� — F_—== �—_—n°_-\\no --no no no no T-wv—'T' W \� —� w w wow— o``�° \ -----���� _ Q° no no \ I — —�— -- SSMH w w W w w w �� -- N — \ w w w w w \mow- w wf�t�w w w ` _ \\� S 9 � \ BRIM-314.86 � � �""� w —w �` DI p5 F I 6 CLAY(E)�309.59 g EXISTI w�W _ / w I �, ` \ G A T— 11 4 6 CLAY W =30- .69 IIII �R E 3 .0 I \ \ ( ) a, a, �E . .BEN 15"RCP�I )=308.98 0 R 15 RCP S =� 8.99 MAIN STREET \\P O �, _ I 1 AR L EL _ PARKING , - 35— �� ---- --� 6--- LBI - ----- -- - / EX. TRAFFIC SIGNAL / / I �/ ) _ BOX AND TRAFFIC I WWW (PRIMARY s i SIGNAL; PROTECT IN / / PLACE AND TO REMAIN �� 6 E T / EX. RAFFIC SIGNAL V ACCESSIBLE TO THE / 01 �n CITY AT ALL TIMES I BOX ND TRAFFIC / I o �)- SIGNAL, PROTECT IN F a II� - 6 o PLACE AND TO REMAtN 0 1 EXISTING 41 ` ACCESSIBLE TO TH _ > > \ REMOVE CURB AS / �3 9 / RIGHT-OF-WAY CITY AT ALL TIMES an an NECESSARY FOR / a, / I m � _L m � I / / INSTALLATION OF � cn an a-i an L a a, �� ��o—}—o— \ o� i CONSTRUCTION S 9 I _ _ — _ — — — _ \ ai --t i a, ILa ENTRANCE 3 W x—x x z=z -x X— _ >---- _ "/ an-�—_ / —m m an ai X=x=x—z z= x=x—z— — — — g a� an an an i f / no no x—x x�x— x —x—x=X --� — — - —L — an aJ — an S 9 EROSION CONTROL LEGEND I�IIIII�I� SILT FENCE OUTLET INLET PROTECTION t } INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN %f FILTER BERM amo CHECK DAM —SFSFSF- -TPTPTP— LD LD / — — — no I j -�- — — — — — - T no � no no x—x—x—x—x=-x=x=x_X — — — _ — =%= — —X— — — — _ _ -- no — — a� 0 0 0— ����� \ — �— /b �.� ( n0-_� ----- fp — x — X X — 1 _ x _X %� — — /- — 0 0 0 k T (� y I 1A/V/ _ — _ Q/' `� 7% — — L no — no n0 X—X X � X> X—X--� o °o °� ° 0- 6 1� V I �—�-� — -- - — — — — — — — — r,u ` X �o� I` 'I — sue. - — — \S 1 \ 3a I I I \ — — — n0 now °°°�°1 I - _ — -- -- _ _ -- �° _-- o i w w I 0& E 1 —— -{� � I � � aSF -� �� —SF� x V 1 CONSTRUCTION FE o �F — SF A o� V Ow o 0 Ol f al it �_ --- - ar F r SF I 41 —SF —SF - -- x _ I � p � �J� _ _ _ N / F I I I I I I \ SILT FENCE (TYP.) III 12 I I \ UNDERGROUND — I LD LD = — — I UTILITIES; PROTE T IN � � � III I I I I I r` �� � o PLACE 1 I� x _— F r L — — — — L — J— — — L �� 1 I CONSTRUCTION GATE I 19 \ \ 1 f I I I III I I I L,,. 0 6 II I I I I / SILT FENCE OUTLET ( I / f IIx I I I I I SILT FENCE OUTLET ( ) II I II AREA = 0.09 AC. LI ITS OF DI TURBANCEII I I 1 1 „� I o I 6 11 1 I I I I j; a x SILT FENCE OUTLET II I I AREA = 0.085 AC. I i I II SILT FENCE OUTLET x I I " I I DRAINAGE AREA I I BOUNDARY � I I � TEMPORARY RUCTION N EASEMENT II 1 u�IIK I I 6 °n//�II I I I I II I �II MI CONSTRUCTION ENTRANCE PROPERTY LINE TO BE F x i I I I I ABANDONED IN PLACE 9 I / ABANDONED PROPERTY LINE IIN PLACE I "I I I I 11 IIx _ I I / I I Ix1I I D.B. �� � � I r� / I x I � _ � IIx I 1� "� � � I I �—s o III I I IXI I 41 x E . ROW L� I� �' I I \ SILT FENCE OUTL T I x I I I AREA = 0.18 ACE �I I 9 I I I Ix ' I, I \ I I ,2 I I-....--- .....t.....� 1 I I i x / I 5 11 ` I I ■ I II I Mir LET PROTECTION x I \ I SILT FENCE OUTLET 11 I I I' I 1 I I I III 1 V A ■ I AREA 0.002 AC. xl I I �v I x1 I I I LIMITSIOF DRAIN INLET I��II I I \ 11 IIII I I DISTURBANCE I� x x X I I ■ 1 SILT FENCE OUTLET r AC x i I \ II I11 I I IIII I 1 i, (TYP.) ® I I 11 I II — I Act / I I I la I i 1 1 SILT FENCE OUTLET L x AREA 0.11 AC. 7 — III II "--�_x X /� — TEMPORARY --SILT FENCE OUTLhh II1II 1 III lI I / CONSTRUCTION AREA = 0.01 AC: xII� I _ ------- EASEMENT ■ -----�— ---- _ X -- ----_ II II I I LD--LD -- -- —_— --------------- ---------------- III I �I� c� X LDx � X J II I\ � � � LD LD TD LD --- — _ I ---_--- — I�—I LD Lp LD Lp — — — — — — — — — — — — -- — EX. RETAINING WALL TO LD LD LD LD LD I I I I REMAIN IN PLACE UNTIL fn LD LD — — — — — _ — _ _ — LD LD J �jI I BUILDING WALL - LD LD LD — — — - —_ _ _ I Cfl I I "Y'I I I I I— — — — — — — — — / / ` INSTALLATION— — — — _ I �a — — LD — �o LD LD LD 9 I / CONSTRUCTION SEQUENCE - STAGE 1: 1. OBTAIN GRADING PERMIT FROM THE CITY OF RALEIGH INSPECTIONS DEPARTMENT. SCHEDULE A PRE-CONSTRUCCTION MEETING WITH CITY OF RALEIGH STORMWATER COORDINATOR, CHRIS BRIDGERS, AT 919-279-1308. 2. INSTALL PERIMETER EROSION CONTROL MEASURES AS INDICATED. CONSTRUCTION ENTRANCE, SILT FENCE AND OUTLETS, INLET PROTECTION, AND CONSTRUCTION FENCE. 3. BEGIN DEMOLITION, SEE SHEET C1.01, DEMOLITION PLAN. 4. STABILIZE SITE AS AREAS ARE DEMOLISHED. SLOPE PROTECTION MATTING, DITCH LININGS, STONE, ETC. ALL DISTURBED AREAS MUST BE STABILIZED WITHIN 14 DAYS OF INACTIVITY. DIRECT RUNOFF TO SILT FENCE OUTLETS. 5. WHEN DEMOLITION IS COMPLETE SCHEDULE AN INSPECTION. WHEN APPROVED PROCEED TO STAGE 2 EROSION CONTROL PLAN. 1 O O (" 5 Ln O CV O CV N 00 0 GRAPHIC SCALE 0 5 10 20 1 inch = to ft. Know what's below. Call before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SILT FENCE TREE PROTECTION FENCE LIMITS OF DISTURBANCE WOODED AREA DIVERSION DITCH CONSTRUCTION ENTRANCE/EXIT DISTURBED AREA = 0.70 AC. SEE SHEET CO.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 ��." CARC,,,�O `��=O ;OFES� lei+•" 0'9 ��: 01i155 = N N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 EROSION CONTROL PLAN -STAGE 1 C6e00 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL \ --------- o — no /----------- / i \ — — — —nQ 10 i -- — — — — — / wCn w w --�= __===— ---- n0—ono-- no no no -------, ----- w�—w w w w w w w �� —=_ �7---no_�r no no n0 no _`� 'T'— — /S I W —� w wow \ a` �no / �\ ` S S M H w w w w \ \ —w w \ w w w w w\` w \ — \ , w w4w w w I � \ AIM-314.86 � �\\ �a w \"'\� w w w \mow DI / I F 6 CLAY(E)—.309.59 EXISTING = o 6"CLAY W =30- .69 CRATE 311.04�` I I \ \ ( ) �\ (n �, ��� E. LE 15"RCPtN.)=308.98 / NOIR ST >> i — — \� \ \ MAIN STREET 15 RCP(S)=3Q8.99 PARALLEL \ EL PARKING P UBLIC -=- b,, s /W) ------ / I I I I � 1\6 s - PRIMARY ,STREET - ss Ss - /i 9 / GV o� m /� // ��� FI 61 6 /WWW I —D / o o EXISTING / >>> / � I / I / —/ RIGHT—OF—WAY / / /—SF—SF—SF— ar'01 01 al a� a� —o o� / / o� o—TP—TP—TP— __ _ N o -/x— — an x—x—x x_= X=X—x_x=X —X — _ — _ — _ — — _ _ _ _ _ / 3n �� / an '— m a� m an an ° a —a a / LD LD F / / /� ! IL�_I x�\ x—x—x=xx—x—x—x x — —X= — � ►n ..� — — — _ _ _—_ _ / °1 °i o m ° m o a o —X— X—X—X—X—x—X—x— TX -`— _ — _ _ — _— — — / / _—_ a1 — — I an \ —x—x—X X—x—x—x—X— — — J — 31I I N / X—X xCONSTRUCTION FENCE xti m SF _x \— S °�Qo° F 0921 E I CO uSF — ", S Con CONST TION FE I I I I s�0� o°�o 4 QO o° o SILJaE (TYP.) � - 0N 317 On o I L LD LD �� \ 4P.) FENCE OUTLET III E� 1 I I x ! v \ 1 X BUILDING OUTLINE 1 19 \ \ � / o f �` 1\ I ❑ I I 16 3 I V) / LI ITS OF DI TURBANCE / x 317 \ I I I I 0 Ix X v I i 314 III / II � � I SILT FENCE OUTLET 7 / I DRAINAGE AREA BOUNDARY I / xl I I `� / I W II 19 / 6 IIx � � '�-1 � � j / ❑ ❑ III TEMPORARY I I I I CONSTRUCTION 6 x m/ III I I // EASEMENT 19 MCI I I o / IIx I I l x I I I I \ CONSTR CTION I I 19 P i k I III 6 M 316 I � \ V I I I c� 118 IIx ' \ / PIV \ AND R LACE ASINECE I II D.B. LD III / I I ESTABLI H GRADE IIx I, 1 - I �EX. ROW ' x � i i /� / I I it \\ ❑ I i i I I I / .........■.. Nunni III / IIIx 6/lp I \ / i x IIIx I li � \ I/ / I IICONTEI CFILTER I I I I s VAULT; TO III I I LIMITS OF / O x REMAIN I I I DISTURBANCE CLOSED UNTIL INAL SITE STABILIZATION01 I III I I / III •I _J II x SILT FENCE OUTLET 6 II II I (TYP.) � � II / I I I ► I 19 TEMPORARY / x CONSTRUCTION ONST U TIONEASEM II �,------------ o I� L I—LD L� Lp — — — — _ — — — — — -- — — ---- — — —EI LxX \ X J i i / LD LD LD --- -- __ — TD — — — — — — — — — — — — — — — — — — — — — — — — EX. RETAINING WALL TO LD LD LD LD LD LD � _� _— — — _ L/ � REMAIN IN PLACE UNTIL 4° LD LD LD LD LD — — — — — — — — — — — — — — — BUILDING WALL I t— — — _ — — I INSTALLATION_ LD Lp_ LD — —LD = J 9 I � ILN NI /I EROSION CONTROL LEGEND CONSTRUCTION SEQUENCE - STAGE 2: 1. MAINTAIN ALL EROSION CONTROL DEVICES FROM STAGE 1 EROSION CONTROL PLAN AS NECESSARY IN ACCORDANCE WITH EROSION CONTROL NOTES ON SHEET CO.00. 2. FOR MAINTENANCE, EROSION CONTROL MEASURES SHALL BE CLEANED ON A REGULAR BASIS AND INSPECTED FOLLOWING EACH RUNOFF -PRODUCING RAIN EVENT. PLEASE NOTE THE CITY OF RALEIGH RESERVES THE RIGHT TO ISSUE A NOTICE OF VIOLATION IF EROSION CONTROL DEVICES ARE NOT PERFORMING CORRECTLY. FOR THIS REASON, THE CONTRACTOR MAY BE REQUIRED TO INSTALL ADDITIONAL MEASURES, AS REQUIRED IN THE FIELD, TO CONTROL SEDIMENT LADEN RUNOFF. 3. BRING THE AREA TO FINAL GRADE AND PAD OUT THE BUILDING FOOTPRINT. DIRECT RUNOFF TO SILT FENCE OUTLETS. AS THE CONTRACTOR DEEMS IT APPROPRIATE, INSTALL STORM, SEWER, WATER AND OTHER UTILITIES THAT CAN BE INSTALLED. PROVIDE INLET PROTECTION TO ALL STORM STRUCTURES AS INSTALLED. CONTECH STORMFILTER VAULT TO REMAIN COMPLETELY CLOSED UNTIL FINAL SITE STABILIZATION. DO NOT CONNECT ROOF DRAINAGE CONNECTION PIPE AS SHOWN ON THE GRADING PLAN UNTIL FINAL SITE STABILIZATION. CONTINUE WITH BUILDING CONSTRUCTION, REMOVING EXISTING RETAINING WALL AS NEEDED. 4. STABILIZE SITE AS AREAS ARE BROUGHT UP TO GRADE WITH VEGETATION, SLOPE PROTECTION MATTING, DITCH LININGS, STONE, ETC., WITHIN 14 DAYS OF COMPLETION. 5. ALL DISTURBED AREAS MUST BE STABILIZED WITHIN 14 DAYS OF INACTIVITY. 6. WHEN GRADING HAS BEEN COMPLETED AND ALL SITE AREA IS STABILIZED, CONTACT THE EROSION CONTROL INSPECTOR FOR AN INSPECTION. 7. ONCE APPROVED, PROCEED TO STAGE 3. P. al CD CD M CD N CD N N 1 00 GRAPHIC SCALE 0 5 10 20 1 inch = 10 ft. Know what's below. Cal I before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SILT FENCE OUTLET INLET PROTECTION INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN FILTER BERM CHECK DAM SILT FENCE TREE PROTECTION FENCE LIMITS OF DISTURBANCE WOODED AREA DIVERSION DITCH CONSTRUCTION ENTRANCE/EXIT DISTURBED AREA = 0.70 AC. SEE SHEET CO.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 A 0rL11TCrT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 N O 2 N N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA I MARK I DATE I DESCRIPTION I EROSION CONTROL PLAN -STAGE 2 C6e0l Construction Documents -n0 — —no _ _ — o — / — — r— — — — — — — — — — -- — — /—I — — — — — — wN w w w w w \ \ �__—=--__= n0—�I no— no no7Tno no o--------7------- �— w w — — F === — �n no no — _WV ----- I W \ —7—w w w w w ` w `� oar \ -----=_____— no—_---n0�-1'°`M' — Qo no —no-- \\ �\ SSMH \ �w w w w w w `� `� `� - — 9 EROSION CONTROL LEGEND M= 314.8 6 w w—mow\ w w w w -w ` �„ w— , \ 7 w w DI / °S / IIIIIIIII I F 6 CLAY(E��309.59 `\ `� EXISTING w�W AT —311.04 6 CLAY W =3 .69 \III �R E— \ ( ELENOIR15"RCP I\l,=308.98 / I � � °, ��, � �/ — — — — -- -- _ MAIN STREET ,P 15"RCP(S) 3Q8.99 s III PARALLEL _ PARKING / ��/ �cO� ss--- `_� -----J669___PUB_LIC__ SS — (PRIMARY --STREET) s 9 -�— / GV a CONSTRUCTION FENCE EXISTING 9 / RIGHT—OF—WAY / / / / J/ / SF —SF —SF an °1 °1 a m a '� ° �I— o ° D i � 9 TP TP — TP �an a ° o I / 3n 01 'tea a W ° n ° o ur d` x 3n 3 S— a a a a o 0 0 / / LD LD n m a an / F + d 4 X O X X X X X y 0� �9 a 0 D— I / 5 E 4 \ 4 \ SILT FENCE (TYP.) — _ a 3n =�- X—X_X d 7 n c x—x— o f SF _ d / \ 0 0 r SF — SF sF SF SF — SF — - ` - s �I g II \ CONSTRUCTION GATE 312 �o° / NSF —SF y V o0 u! d \ SF SF SF 4 \ \CoOcQC��[ / I \ \—SF—SF_SF—SF SF _ 4 -�_ � (TYP.) Y \ --------o V o� o° o (P F o o� O° O 0 -�— SF ,—SF�SFS ?' SF SF S �� SF _—. an al J ---- . ❑ ❑ , Q Q �SF — SF QISF F SF _ \ g o0 oOuO u , oO���Voo / d _ -- SF S — SF � F — SF i \ a w ti / I / 9 � ® ti I / v ILT FENCE OUTLET _ , --- _ I TYP.) I I _ CONSTRUCTION ENTRANCE; --f- - ti I \ INLET PROTECTION \ COORDINATE WITH CITY EROSION N (TYP.) CONTROL INSPECTOR FOR REMOVAL I I I I I OF CONSTRUCTION ENTRANCE FOR P I I I / I \ \ INSTALLATION OF SIDEWALKS, X N o DRIVEWAY, TREE GRATE, STORM I I I I I \ \ LI ITS OF SERVICE LINES, AND CURB AND / I DI TURBANCE I A GUTTER. I I \ I I / d \ N a \ IIIII I I d � _ I N °El / I TEMPORARY I I I CONSTRUCTION SILT FENCE OUTLET INLET PROTECTION INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN FILTER BERM CHECK DAM SILT FENCE TREE PROTECTION FENCE LIMITS OF DISTURBANCE WOODED AREA DIVERSION DITCH CONSTRUCTION ENTRANCE/EXIT DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 -(N CARS,,, �''•_ E5 2 0 7% 055 ��� •:�.::.::•� PSG ; IL\ a/ a rn EASEMENT II I 6 9 MCI a V / — v �'I T .� I` I 19 I P I I` 6 \ II I 118 L LD I I I I D.B. ° xl I I / I I I I / I I III III , II II 19 6 0 \ II II I I I / CONTECH STORMFILTER I I I III VAULT; VAULT TO REMAIN COMPLETELY I I MINIM I � L r L I •I ( CLOSED ANIMA FINAL 1 1 I 19 SITE 0 I I LIMITS OF ——,—_i--r— DISTURBANCE W I\ I I I I II I I t I I I cs O ------��- - � I � � I I 6 I I I � �� II I I � � ♦ 7-7— SILT FENCE OUTLET II I to I U --r——I--r_r_ I I I I I (TYP.) I I I I I I � I •— I I it I I I I j ROOF DRAINAGE LINE; I I I I I I I I TEMPORARY CONSTRUCTION DO NOT INSTALL CONNECTION UNTIL I I EASEMENT •— AFTER FINAL SITE STABILIZATION / 1-9 N •nn-11 xIn �, x r�--- ---- n J -'�'---------------------- ---------- I 0 V) o IF L I — — _ I--_—_—_—J— _—_— — --- I-�— — � / L.L LD LI I X—X—X I I — — — — I _ — — _ _ _ — — — — _ _ I LD II I / / LD LD LD — — — — — -- -- — — -- — — — -- -- — — --� — — — -- — -- -- — -- -- — — -- —_-- -- — —_— -- / /I I O � LD LD�LD LD LLD LD LD �---------------- --- _— ��J I I I V I _ I — co II Ti 1� I --_---- /` I I LD LD LD�_LD Lp _ 9 —-- - �ILD O 1 I / _ _ DISTURBED AREA = 0.7 AAC. CONSTRUCTION SEQUENCE - STAGE 3: 1. MAINTAIN EROSION CONTROL MEASURES FROM PREVIOUS STAGES. INSTALL TEMPORARY INLET PROTECTION AS SHOWN ON THIS PLAN. TREE PROTECTION, CONSTRUCTION ENTRANCE, SILT FENCE AND OUTLETS, INLET PROTECTION, AND CONSTRUCTION FENCE. COORDINATE WITH THE CITY'S EROSION CONTROL INSPECTOR FOR REMOVAL OF THE CONSTRUCTION ENTRANCE AND SILT FENCE FOR INSTALLATION OF STREETSCAPE, DRIVEWAY, CURB AND GUTTER AND SIDEWALKS ADJACENT TO PARKING DECK DRIVE. 2. ONCE UPSTREAM DRAINAGE AREAS HAVE BEEN STABILIZED, INSTALL ROOF DRAIN CONNECTION PIPE TO CONTECH STORMFILTER VAULT PER SHEET C9.00. COORDINATE CONNECTION WITH THE PLUMBING PLANS. 3. FOR MAINTENANCE, EROSION CONTROL MEASURES SHALL BE CLEANED ON A REGULAR BASIS AND INSPECTED FOLLOWING EACH RUNOFF -PRODUCING RAIN EVENT. PLEASE NOTE THE CITY OF RALEIGH RESERVES THE RIGHT TO ISSUE A NOTICE OF VIOLATION IF EROSION CONTROL DEVICES ARE NOT PERFORMING CORRECTLY. FOR THIS REASON, THE CONTRACTOR MAY BE REQUIRED TO INSTALL ADDITIONAL MEASURES, AS REQUIRED IN THE FIELD, TO CONTROL SEDIMENT LADEN RUNOFF. 4. STORMWATER CONTROL MEASURE CERTIFICATIONS AND AS -BUILT PLANS MUST BE PROVIDED TO STORMWATER CONTROL INSPECTOR, FOR REVIEW, 7 DAYS PRIOR TO FINAL INSPECTION. CERTIFICATIONS AND AS -BUILT PLANS MUST BE ACCEPTED PRIOR TO APPROVAL OF FINAL INSPECTION. 5. WHEN CONSTRUCTION IS COMPLETE, ALL AREAS ARE STABILIZED COMPLETELY AND STORMWATER CONTROL MEASURE CERTIFICATIONS AND AS -BUILT PLANS ARE ACCEPTED BY THE CITY OF RALEIGH, SCHEDULE FINAL INSPECTOR THROUGH CITY OF RALEIGH PERMIT PORTAL (PERM ITPORTAL.RALEIGH NC.GOV). 1 O O (" 5 O CV O CV N 00 GRAPHIC SCALE 0 1 10 20 1 inch = 10 ft. Know what's below. Cal I before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SEE SHEET CO.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 EROSION CONTROL PLAN -STAGE 3 6e02 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL GLASS HGT GLASS / NIDTH W3TH CLEARANCE 36, GLASS / HGT / FRONT VIEW SIDE VIEW SPECIFICATIONS: POWDER COAT ALUMINUM STRUCTURE (FINISH TO BE DETERMINED) " CLEAR LAMINATED TEMPERED SAFETY GLAZING 130y ❑.D," GREY ACRYLIC HIP ROOF WITH FASCIA 66" CURVELINE BENCH WITH RECYCLED PLASTIC (CEDAR) SLATS, FINISH TO MATCH 63" LEAN RAIL RECYCLED PLASTIC (CEDAR) FINISH TO MATCH ADA COMPLIANT PZ- BRASCO INTERNATIONAL, INC. 1000 MT. ELLIOTT 86" CURVELINE BENCH DETROIT, MICHIGAN 48207 68 Bx 1-800-893-3665 WWW.BRASCO.COM D CUSTOMER CITY OF RALEIGH 17].D FLOOR PLAN PROJECT MODEL TL 510 C DRAWN BY FBZ DATE 8-19-05 SHEET APPROVED BY DATE SCALE NONE REV. RASCO SHELTERS THIS ORAMNa IS PROPRIETARY AND IS FOR 7HE SOLE USE OF OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED Wf1HOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL IN -GROUND MOUNT SURFACE MOUNT 33-36" 35" 11 �11111=IIIII=11111=1 III=11111=IIIII=IIII (IIII=11111 -11111=IIIII=11111=III 11111=I I=11111 IJlll1=11TI IIII=11111=IIII IIII-=1111-= 111-11111 IIW=WII=UW==IIW=Ul11= WII=WTI I UW=IWI=11W= =mrl=lm=FED mrl=ml=m1 =m1= =mrl=FED=mrl 11111=11111=IIIII=1 � � III=11111=IIIII=IIII (IIII=11111 � � 1111�11111=11111=IIIII=IIII =11I=1ill I=11I I I I=11I=11I=11I I I I I=11I=11I-11I I�1=1I L=-I I=1I I I UW=pW= W11=WIl=UW= UW=UW=IIW= UW= =11111=111t1 =fIIII=_IIIII=11111 =1IIIIJIIII=11111 = _=11111=IIIIIJIII BIKE RACK INSTALLATION: SURFACE MOUNT - WHEN INSTALLED ON 35" CONCRETE SURFACE, USE 3/8" ANCHORS TO PLATE MOUNT. SHIM AS NECESSARY TO ENSURE VERTICAL PLACEMENT. IN -GROUND MOUNT - WHEN INSTALLED ON PAVERS OR OTHER NON -STABLE SURFACES, EMBED INTO BASE. CORE HOLES NO LESS 24" THAN 3" IN DIAMETER AND 10" DEEP. ® 6„ STANDARD BIKE RACK CITY OF RALEIGH STANDARD DETAIL REVISIONS DATE:8/1/18 WTTOSCALE BIKE RACK DETAILS B-20.03 1" ASPHALT SURFACE COURSE (NCDOT SF-9.5A) 2" ASPHALT BINDER COURSE (NCDOT 1-19.OB) 6" ABC STONE BASE COMPACTED SUBGRADE SEE SPECIFICATIONS FOR REQUIRED MATERIALS. WOVEN GEOTEXTILE (n LJ ry D Q iL H � U 0 0 A 1 Y" DEEP CUT SHALL BE MADE PERPENDICULAR TO BACK OF CURB AND THEN PARALLEL WITH GUTTER LINE FULL DEPTH CUT SHALL BE MADE PERPENDICULAR TO BACK OF CURB TYPE A TO BE USED ON STREETS WHERE FINAL LIFT OF ASPHALT HAS BEEN INSTALLED 45" < BREAK ^T^^ • ^ NOTES: 1. CURB AND GUTTER SECTION SHALL BE REMOVED IN ACCORDANCE WITH DRIVEWAY WIDTH APPROVED BY THE CITY. 2. IF PERPENDICULAR CUT IS LESS THAN 5' FROM NEXT JOINT. THEN THE PARALLEL CUT SHALL BE MADE TO THAT JOINT. 3. THIS METHOD IS NOT ALLOWED IN NEW ROADWAY CONSTRUCTION. PORTION TO BE REMOVED TYPE B USED ON STREETS WHERE FINAL = ASPHALT HAS NOT BEEN INSTALLED CITY OF RALEIGH PUBLIC WORKS DEPARTMENT DATE:911AS MOTTOSCALE STANDARD METHOD OF REMOVING EXISTING CURB (FOR A DRIVEWAY APRON INSTALLATION) T-10.24 ALUMINUM EDGE RESTRAINT GALVANIZED STAKE BRICK OR REFER TO MANUFACTURER'S CONCRETE PAVER RECOMMENDATION FOR 2 3/8" (60 MM) MIN. THICKNESS FfA INSTALLATION q2s� 0 1" TO 1 1/2" (25 - 40 MM) ,p\�•C 20�2 VARIABLE WIDTH DEPENDENT T COMPACTED BEDDING SAND / O� 6' ON GRASS STRIP WIDTH ,ceo oc•a •c c•o.°o. ac•a •c o°a coo a°cc a°cc `n °a •coe EXPANSION JOINT \ COMPACTED AGGREGATE BASE 8.5' ��92s/off✓��2>. 4" (100 MM) MIN. THICKNESS �.`� .. �C.fQP��\O�,O�� \GQo \\\\\\\\\\\\\\ �� \\ OG��fJO/2T COMPACTED SOIL SUBGRADE \ � '• • 11 ��000e�Go� SECTION 1 a \ \\\\\\\\\\\ USE GRANITE CURB DETAIL; REFER TO HARDSCAPE PLANS 1/2" EXPANSION JOINT \\\\\\\\ 3.5' RADIUS MAXIMUM \\\\\\\\\\\ AND CONTROL) JOINTS OW TOP 15O(4. PAVERS $CRERTE AVE OC \\\\\\\\\\\\\\\ \\\ @ 20 ( ) THICKNESS <• \\\ 8\ ° o ° P • p o°o&'" e� EXPANSION %/l/ gob ".^: •o°o vp. c°a. c. •c c°a• c°a. ac•On•a° 1 " TO 1 1/2" (25 - 40 M M) oo.°00000 000 °°000o COMPACTED BEDDING SAND • ° o 0 00 JOINT °°pv. O �o� �Do v ° 0 . v o0 000 �o 000'o a•,•• ,,.V v/� �0 se°d:��%� oa, 000 COMPACTED AGGREGATE BASE 4" (100 MM) MIN. THICKNESS SEE T-10.01.2 FOR ADDITIONAL NOTES COMPACTED SOIL SUBGRADE SECTION 2 6" EXPANSION JOINT 1/4"IFT (MAX) SLOPE * T 5•' 6" SIDEWALK NOTES: 1. BRICK OR CONCRETE PAVERS ALLOWED ONLY UNDER SPECIAL CONDITIONS. T' 6 2. THICKNESS OF BASE MAY VARY WITH SUBGRADE/TRAFFIC CONDITIONS. 3. SCATTER SAND OR SCREENINGS OVER COMPLETE WORK AND SWEEP INTO CRACKS. SHEET 1 OF 4. CONCRETE PAVERS SHOULD CONFORM TO REQUIREMENTS OF ASTM C-1319. 2' 6.5' 6' BRICK PAVERS SHOULD CONFORM TO REQUIREMENTS OF ASTM C902-95 CITY OF RALEIGH 5. SEE CITY OF RALEIGH CODE SECTION 10-7001 (D) FOR CONDITIONS UNDER CITY OF RALEIGH STANDARD DETAIL WHICH CONCRETE / BRICK PAVERS ARE ALLOWED. STANDARD DETAIL 4c USE 6.5" WHEN DRIVEWAY IS USED IN LIEU REVISIONS DATE:8108 NOT TO SCALE REVISIONS DATE: 60/18 NOTTOSCALE OF A WHEELCHAIR RAMP TO ACCOMMODATE 12:1 MAXIMUM SLOPE (ADA COMPLIANT), DRIVEWAYAND CONCRETE/BRICK PAVER SUCH AS IN A CUL-DE SAC. SIDEWALK DETAIL SIDEWALK DETAIL T-10.01.1 T-30.03 ONLY. REFER TO HARDSCAPE DETAILS COMPACTED S MEETING SPECIF 4" AGGREGATE BASE ^^'<ER ROD (STRAIGHT JOINTS ONLY) 1. REFER TO LAYOUT PLAN FOR SIDEWALK LOCATIONS, TYPES AND WIDTHS. CONCRETE SIDEWALK - PLAN AND SECTION 2. REFER TO DETAILED LAYOUT PLAN FOR SPECIFIC JOINT LOCATIONS AND SPACING. 3. USE THIS DETAIL FOR TYPICAL JOINT SPACING WHEN NO SPECIFIC JOINT SPACING IS INDICATED ON PLANS. 4. MAXIMUM SIDEWALK CROSS -SLOPE IS 2%. 5. EXPANSION JOINTS SHALL BE INSTALLED WHERE CONCRETE PAVEMENT ABUTS ALL VERTICAL SURFACES INCLUDING BUT NOT LIMITED TO ALL BUILDINGS, STRUCTURES, STAIRS, CURBS, COLUMNS, WALLS, LIGHT POLES, ETC. 6. WHERE WALK ABUTS RIGID STRUCTURE, JOINT SHALL BE WATERTIGHT. 7. PROVIDE EXPANSION JOINTS @ 20' O.C. MAX UNLESS OTHERWISE SHOWN/ REQUIRED. (SEE MATERIALS & STAKING PLAN) 8. TOOL JOINTS TO A MIN. DEPTH OF 1". CONTRACTOR TO CLOSELY COORDINATE LOCATIONS AND DESIGNS PRIOR TO AND DURING CONSTRUCTION. 9. ALL CONCRETE SHALL BE 3,000 PSI UNLESS OTHERWISE REQUIRED BY PROJECT SPECIFICATIONS. 1" ASPHALT SURFACE COURSE (NCDOT SF-9.5A) 2" ASPHALT BINDER COURSE (NCDOT 1-19.OB) 8" ABC STONE BASE COMPACTED SUBGRADE SEE SPECIFICATIONS FOR REQUIRED MATERIALS. WOVEN GEOTEXTILE ASPHALT PAVEMENT - LIGHT DUTY ASPHALT PAVEMENT - HEAVY DUTY PAVEMENT DETAIL PAVEMENT DETAIL NOTE: ASPHALT AND CONCRETE SECTIONS ARE SHOWN WITH MINIMUM THICKNESS. ON -SITE GEOTECH SHALL VERIFY THESE PRIOR TO CONSTRUCTION BASED ON FIELD CONDITIONS AND ADJUST AS NEEDED. OR, REFER TO CURRENT GEOTECHNICAL REPORT FOR PAVEMENT SECTION RECOMMENDATION. O O (" 5 O CV O CV CV 00 PAVER JOINT: POLYM 1" POLYMERIC JOINTING SAND S1 I`r d CONCRETE COMPACTED SUBGRADE MEI GEOTECHNICAL/STRUCTURAL F 2" PVC WEEP SPACED 8' �.�. FILL WITH WASHED PEA GRAVEL f�I�l\I��[iPLT1�■�i7s:7�y�:7�[�I�iP►I�it;7�y�:ifi7pIVT�I.Yil_��i�I�l_ll� PEDESTRIAN PAVER NOTES: 1. CONTRACTOR TO CONSTRUCT A 4' X 4' MOCK-UP OF EACH PAVER TYPE FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO FULL INSTALLATION. MOCK UP MAY BE INCLUDED AS PART OF FINAL INSTALLATION IF APPROVED. 2. INSTALL PAVERS PER MANUFACTURER'S SPECIFICATIONS. CUT PAVERS AS NECESSARY BUT NOT MORE THAN 1/3 OF THE TOTAL WIDTH OF THE PAVER TO AVOID SLIVERS. 3. REFER TO HARDSCAPE MATERIALS PLAN FOR PAVER PATTERNS, LOCATIONS OF PAVER TYPES AND PAVER BAND LOCATIONS. 4. CONTRACTOR TO VERIFY DEPTHS OF AGGREGATE BASE WITH GEOTECHNICAL ENGINEER. A A _ PREFORMED FIBER EXPANSION T WITH COLORED JOINT -ANT/CAULK. COLOR SHALL MATCH \CENT CONC. AND BE APPROVED BY ERAS REPRESENTATIVE TOOLED JOINT (TYP) A SCENT PAVED OR MIN. 1" DEEP AS SHOWN TICAL SURFACE ON PLAN DETAIL SHOWN FOR REFERENCE ONLY. REFER TO HARDSCAPE DETAILS Xz" EXP. JT. MATERIAL f-- 1 NOT TO SCALE CONCRETE ABC SETTING BEDS S';I:':L°'11^11"'IG"L"li"11"IG"11"IL"11"1:"1:'°L"1^°L"11"1:"IL"L' '1101:L��LIILII&L��L�TL�TR��IL�TI:T�L��ILI'1:17:I�LII Ii�;r.��1r11111Ta;,1: �le_,Ir-.u11.,IG.,IIIII:IIL,.IC.,I:,S�:I: i!lli; 9:��L�:IL;'I,L,r II ItI�r 1fi" GRANITE CURB SEE STREETSCAPE PLANS L ABC FILL BOTTOM OF TRENCH GRANITE CURB SETTING METHOD NOT TO SCALE DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 57 03i 355 ,,, •tiG I NEB•• : ,, a U a � ° a III=III=III-1 I II � II I I -III -_III- 4" COMPACTED III -III- AGGREGATE BASE O COMPACTED SUBGRADE MEETING PROJECT SPECIFICATIONS SECTION A -A SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: N N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 SITE DETAILS C goo Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER CITY OF RALEIGH CURB RAMPS GENERAL NOTES 1. CITY OF RALEIGH STANDARD CURB RAMPS HAVE BEEN DEVELOPED IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA) AND PUBLIC RIGHT OF WAY ACCESS GUIDELINES (PROWAG). 2. CURB RAMPS SHALL BE PROVIDED AT LOCATIONS AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. SIDEWALK ACCESS RAMPS SHALL BE LOCATED AS INDICATED IN THE DETAIL, HOWEVER, THE LOCATION MAY BE ADJUSTED IN COORDINATION WITH THE CITY OF RALEIGH WHERE EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. AFFECT PLACEMENT. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. 3. THE WALKING SURFACE SHALL BE SLIP RESISTANT. COLORS FOR THE DETECTABLE WARNING AREA SHALL BE DARK CHARCOAL GRAY FOR CONTRAST WITH LIGHT PATHWAY COLORS AND LIGHT CONCRETE GRAY FOR CONTRAST WITH DARK PATHWAY COLORS. 4. NO SLOPE ON THE SIDEWALK ACCESS RAMP SHALL EXCEED 1"/FT (12:1) IN RELATIONSHIP TO THE GRADE OF THE STREET. 5. IN NO CASE SHALL THE WIDTH OF THE SIDEWALK ACCESS RAMP BE LESS THAN 48" HOWEVER, RAMP MAY EXCEED 48. 6. USE CLASS A (3000 PSI) CONCRETE WITH A SIDEWALK FINISH IN ORDER TO OBTAIN A ROUGH NONSKID SURFACE. 7. A 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE CONCRETE SIDEWALK ACCESS RAMP JOINS THE CURB AND ALSO WHERE NEW CONCRETE ABUTS EXISTING CONCRETE. B. CURB RAMPS SHOULD BE PLACED PARALLEL TO THE DIRECTION OF TRAVEL. SHEET 6 OF 6 RAMP WIDTH AREA VARIABLE 4' MINIMUM m m o 0 o m m m m m m o m m m m BASE DIAMETER e® eo oom oo mmo ee oe omo om om eom Dm mo mo m 0.45"RTO 0.70"R om Do o m m m o m o m m o 0 0 o m o o TOP DIAMETER OF NO F o 0 0 0 0 0 0 o m o 0 0 o e o m LESS THAN 50% TO NO MORE THAN 65% OF THE BASE DIAMETER 0.651, 1.8" TO 0.9" TO MIN. 1.a• ' � z.a• 2' PRECAST CLASS •B' T CONCRETE DETECTABLE WARNING DOMES CONCRETE PAVER 4' MIN LANDING SLOPE 12:1 MAX (6' MIN.) 1/41IFT 2' DETECTABLE DEPRESSED CURB STANDARD 2'-6' 4• WARNING DOMES SEE NOTE W CURB 8 GUTTER T 6' +: CONC IDE ACCEWa-K T RAMP ' EXPANSION JOINT 4' CONCRETE FOUNDATION FOR WARNING DOMES TO BE WITH SAME POUR AS RAMP, FLARES, ETC. PAY LIMITS FOR CURB RAMP SIDEWALK WIDTH 6"W X 12"D CONCRETE CURB 8' MIN 1/2" EXPANSION JOINT (TYP) SSIDEIWALKWIDTH 2 '24" TYP •\/� R=1' (TYP) 1T MIN �� Gov, DEPRESSED 2'-8" 6' (TYP) CURB & GUTTER 4' MIN. DETECTABLE WARNING �\ SURFACE (TYP) 1/2"EXPANSION DEPRESSED I CONCRETE DEPTH JOINT (TYP) 2'-6" CURB & GUTTER (HEIGHT VARIES RAMP / FLARE 6" CURB REVEAL DETERMINED LANDING 4" NOTE: • USE SMALL FLARE ONLY WHEN A CURB BY FLARE SLOPE) WOULD DIRECTLY CONFLICT WITH APPROACHING VEHICLE TURNING MOVEMENTS. TYPE N-3 O 8.33% (12:1) MAX RAMP SLOPE O CROSS SLOPE: 2.00% O CURB RAMPS REQUIRE A (4'-0") MINIMUM LANDING WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. O RAMPS AND DOMES SHALL BE INSTALLED THE SAME WIDTH AS THE SIDEWALK. W MIN LANDING REPLACE FLARE SIDEWALK AREA WITH CURB ALONG RAMP; TOP AND 1/2"EXPANSION REPLACE FLARE BOTTOM OF CURB JOINT (TYP) 1/J(VPON WITH CURB ALONG TO BE FLUSH AT z JOINT(TYP) TOP OF RAMP; SEE RAMP; TOP AND ' SITE AND GRADING BOTTOM OF CURB PLAN = / �" • �\ 1 TO BE FLUSH AT DETECTABLE WARNING 3 TOP OF RAMP; SEE SURFACE (TYP) m00%°tor SITE AND GRADING 6'(TYP) PLAN 4' MIN. \\ DEPRESSED 2'-6" CURB &GUTTER 1/2" EXPANSION DEPRESSED 2'-6" JOINT (TYP) CURB & GUTTER (HEIGHT VARIES CURB REVEAL DETERMINED BY FLARE SLOPE) CONCRETE DEPTH TYPE N-3A SHEET 3 OF RAMP/FLARE s" LANDING 4' (COMMERCIAL/RETAIL USE) CITY OF RALEIGH STANDARD DETAIL REVISIONS GATE: W/18 NOT TO SC4LE CURB RAMPS (NEW DEVELOPMENT) T-20.01.3 (W MIN LANDING) SLOPE 12:1 MAX (94' MIN.) 2" 2'DETECTABLE DEPRESSED CURB ARMING DOME STANDARD 2'- 6" SEE NOTEM CURB & GUTTER EXISTING CRETE ..-..,. ..:.:' SURFACE APPLIEDIRETROFIT 4" CONCRETE SECTION "A -A" DETECTABLE WARNING SURFACE SYSTEM FOUNDATION WITH DETECTABLE WARNING PAVERS 49.De0 W DIA C 140LES bPL. ^YP.ISLOCATpN91� a000®0@8 S 0000006 0OO®®00®000°0®®®®®®000000000000 00000000000®e®00000000�1®000®® �� a0000�ooG®®®0000�eo®®®®oo�oo®® 0 0 0 0 0 0" 0" 00 0 0 0 0 0 0 0 0 0" 0° 0 0 aoo�e�o�®®e®000000®®®000©oo®® 00"00 NOO 0000"000000000 NOO 00000000 000 °ON000®ON0000000ONNNOON®® 00"000000"N0000000000"00"p00"00"0000 *00000061000000®00000061000000® � v y F "MF SOME 191X 1 1W LG. EXPANSKN ANCHOR VILEW NST9 44XnE N RAMP SECTION Ta WITH DETECTABLE WARNING PAVERS �o-P< Am I£ .WO 9 BIOEB DIA 16 DN.240 PL $y .DLD DEG PDIM o NOTE; IF, .0I6W 9 THIS APPLICATION ONLY TO BE USED WHEN RETRO FRYING EXISTING BARRIER FREE RAMPS ADD $ aoD 0 -l•i �" 9ECTION'B• SCBLE SHEET 2 OF 4 NOTES: 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. SIZE OF PAVER SHALL BE V X 1'. 2. OBTAIN 70% CONTRAST VISIBILITY WITH ADJOINING SURFACE, EITHER LIGHT ON DARK, OR DARK ON LIGHT SEQUENCE COVERING THE DETECTABLE WARNING AREA. NOTES: 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL 2. OBTAIN 70% CONTRAST VISIBILITY WITH ADJOINING SURFACE. EITHER LIGHT ON DARK, OR DARK ON LIGHT SEQUENCE COVERING THE DETECTABLE WARNING AREA. SHEET 3OF4 RAMP SECTION WITH DETECTABLE WARNING SURFACE CAST -IN -PLACE SYSTEM (4' MIN LANDING) SLOPE 12:1 MAX (5'4" MIN.) 2' DETECTABLE DEPRESSED CURB WARNING DOMES STANDAR ° ISEE NOTE #1 CURB & GI .4CNC.S/bALKCESS RAMPSION JOINT DETECTABLE WARNING SURFACE SYSTEM NOTES: 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. 2. OBTAIN 70% CONTRAST VISIBILITY WITH ADJOINING SURFACE, EITHER LIGHT ON DARK, OR DARK ON LIGHT SEQUENCE COVERING THE DETECTABLE WARNING AREA. SHEET40F4 CITY OF RALEIGH PUBLIC WORKS DEPARTMENT REVISIONS DATe. vfn8 NOT TO SCALE DETECTABLE WARNING CAST -IN -PLACE T-20.04.4 TYPICAL MH FOR STORM SEWER STANDARD MANHOLE B A � RING AND COVER \ ? rar� � G N W 12 4" '-� OR 5'-0• > ) . a'-o SLOPE 45' o , x C C 6' THICK UP TO 12' DEEP 12" THICK OVER 12' DEEP O LOPE 6"/12" °6' 0° 3000 PSI B A 3000 PSI CONCRETE GROUT SECTION A -A SECTION B-B B NOTES: 1. DEPTH MEASURED FROM TOP OF CASTING TO INVERT OF MANHOLE. 2. PRECAST MANHOLE COMPONENTS SHALL MEET ASTM-C-478 REQUIREMENTS. y 3. SEE STANDARD. SW-10.10 FOR MANHOLE COVER DETAIL. A A 4. DOMESTIC CASTINGS REQUIRED 8- WITHIN STREET RIGHT-OF-WAY. 4• v CITY OF RALEIGH STANDARD DETAIL B REVISIONS DATE: 0118 NOTTOSCALE TYPE A STANDARD CLASS "A" SECTION C-C MANHOLE SW-10.05 PIPE SIZE MH DIAMETER 12-24" 4'-0" 30-42" 5'-0" 48" 6'-0" 8" ADS N-12 COMPATIBLE ADAPTOR W/ SCREW TYPE SLOPE TRENCH SIDES SLOPE TRENCH SIDES CLEANOUT PLUG CONCRETE PER OSHA REQUIREMENTS PER OSHA REQUIREMENTS oD PAVEMENTW SLAB BASIN W IIII IIII IIII IIII IIII IIII IIII III SIZE (MIN.) 12" 4'-0" \ SELECT 12" 8" MIN. 15" 4'-0" \\ FILL 12" 12" PVC OR HDPE DRAIN 16" MIN. 18" 4'-6" 8" ADS N-12 PIPE PIPE; SIZE AND 24 5 -0 Z (LENGTH AS REQUIRED TO MATERIAL AS SPECIFIED 30" 6'-0" SELECT FILL `D INITIAL MATCH FINISH GRADE) ON SCHEDULE 8" MIN. BACKFILL DRAIN BASIN WITH H-25 RATED O D O D BACKFILL MATERIAL SHALL BE CRUSHED STONE MIN 4" HAUNCHING STD. PATTERN DUCTILE IRON OR GRAVEL MATERIAL MEETING CLASS 1 OR 2 BEDDING ADS N-12 GRATE OR SOLID LID; SIZE AND TYPE AS SPECIFIED ON SCHEDULE AS SPECIFIED IN ASTM D2321. REQUIRED IF CO 45• BEND BACKFILL MATERIAL SHALL BE PLACED _ IIII TRENCHING _ III UNIFORMLY IN 12" LIFTS AND COMPACTED. -IIII -IIII -IIII IN ROCK IIII -IIII -IIII -IIII IIII TYPICAL INSTALLATION IN PAVEMENT AREAS -IIII - -IIII - D+4' MAX DRAIN BASIN WITH DUCTILE MIN. 6" WIDE BY 4" THK. IRON GRATE OR SOLID LID; CONC. PAD TO BE RIGID PIPE FLEXIBLE PIPE SIZE AND TYPE AS FORMED AROUND DRAIN I SPECIFIED ON SCHEDULE BASIN FRAME. INCLUDES REINFORCED CONCRETE AND DUCTILE IRON PIPE INCLUDES CORRUGATED METEL, HDPE, AND PVC PIPE ADS N-12 "D" x 8" REDUCING WYE GENERAL NOTES I 1. BEDDING SHALL BE CLASS I -A WORKED BY 6. SELECT BACKFILL NOT UNDER PAVED AREAS HAND. IF GROUNDWATER IS ANTICIPATED, CAN BE CLASS IV -A COMPACTED TO 95% THEN BEDDING SHALL BE CLASS I-B STANDARD PROCTOR. PVC BODY COMPACTED TO 95% STANDARD PROCTOR. 7. ALL MATERIALS ARE CLASSIFIED IN ACCORDANCE ADS N-12 I 2. HAUNCHING SHALL BE WORKED AROUND THE PIPE WITH ASTM D 2321-LATEST EDITION. END CAP WATERTIGHT ADAPTORS I BY HAND TO ELIMINATE VOIDS AND SHALL BE CLASS 8. ALL MATERIALS SHALL BE INSTALLED IN Q FOR USE WITH ALL I -A OR CLASS I-B OR CLASS II COMPACTED TO MAXIMUM 8" LOOSE LIFTS IN ACCORDANCE PVC OR HDPE DRAIN PLASTIC PIPING SYSTEMS 95% PROCTOR. WITH ASTM D 698. CLASS III AND IV -A PIPE; SIZE AND ELEVATION PLAN 3. INITIAL BACKFILL SHALL BE CLASS I -A MATERIALS SHALL BE COMPACTED NEAR MATERIAL AS SPECIFIED WORKED BY HAND, OR CLASS I-B OR CLASS II OPTIMUM MOISTURE CONTENT. ON SCHEDULE COMPACTED TO 95% STANDARD PROCTOR. 9. FILL SALVAGED FROM EXCAVATION SHALL BE TYPICAL INSTALLATION IN YARD OR SIDEWALK AREAS 4. INITIAL BACKFILL NOT UNDER PAVED AREAS FREE OF DEBRIS, ORGANICS AND ROCKS LARGER THAN 3". NOTES: CAN BE CLASS III COMPACTED TO 90% STANDARD PROCTOR. 10. ALL TRENCH EXCAVATIONS SHALL BE SLOPED, 1. THE DIAMETER OF THE PIPE "D" MAY VARY FROM 8" - 15" NOTES: 1. GRATES WITHIN LAWN AREAS TO BE 12" STANDARD PATTERN DUCTILE IRON. 5. SELECT BACKFILL SHALL BE CLASS I, ll, OR SHORED, SHEETED, BRACED, OR OTHERWISE SUPPORTED IN COMPLIANCE WITH OSHA 2. ALL JOINTS SHALL BE WATER TIGHT 2. GRATES WITHIN MULCHED PLANTING BEDS TO BE 12" DUCTILE IRON, ATRIUM STYLE. III COMPACTED TO 95% STANDARD PROCTOR REGULATIONS AND LOCAL ORDINANCES. 3. GRATES WITHIN SIDEWALK AND PEDESTRIAN AREAS TO BE 12" ADA-COMPLIANT DUCTILE IRON. WITH TOP 24" COMPACTED TO 100% STANDARD PROCTOR. 3. ADS N-12 PIPE AND APURTANENCES MAY BE SUBSTITUTED 4. AREA DRAINS SHALL BE FURNISHED WITHOUT SUMP, ELSE SUMP SHALL BE FILLED WITH LEAN CONCRETE. WITH LIKE HIGH DENSITY POLYETHLENE PIPE OR PVC PRODUCTS STORM WATER CLEAN OU T, N TS O O (" 5 O CV O CV CV CO AREA DRAIN, NTS TRENCH DETAIL FOR STORM DRAIN AND UTILITY PIPES SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, INC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, INC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 III11 I1111"A CAR(,,�,4'. Q �� 34 355 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 SITE &STORM DRAINAGE DETAILS C8.01 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER 0 Z Z a > _P PF-: Z Z 2 Was a JJ� z � �aU W � Wawc9 z = o W V _ �ZF-W W LL ZW W 0 > W J LL D U U o ow =��� O IIIII ° �W�Z LLJ W LL ¢ LLI Ow �p�WO J= ��LL0 Frn OW mF w Z pp ° - I I I I Lu z0 Z�WQ~ ¢W c9a CA W LL 2 o C9 Z U F W z z o x w 000 I �°�11111— V1 U x w N �- Of 0 V) U- W �� �� �\ �� 0°°0°�0 �o ag°-°_o g��3 a 3\ \_ IIIII o w W W m W O z IY Z p w r 00°°0000 I I I I 000 0 o°ppopo— ° ¢ 1= 0 o J o 0 z o z z w Q, z�OZ \ IIIII=1 IC W U z w p w U 000op $�° Z OW W z Z a Z Q =IIIII=1 III—IIIII= D � U W tY F -i Z oo p0�j p e W ¢o rnULLO_ r 7q uTu Z = O(D LL � x U °00 w W HillUZ W r� 0 ILL W ° Lu IIIII � g o0p °0� m m a c9 z N 00 LL �_ o " ° Lu IIIII ru) z❑ W ova o w LL J IIIII a C W. a Y;'.'. N w IIIII I W oa z 00°IIIII o00 W > 3 l IIIII ZW Q= F 00 II II o �� _II _/- z > LU m ZCID IIIII LLl -i LCUO �v W W xo F- Z 0LD 0 U Z - 1311--� III=III= > U 0 IIIII J O Z �wUV) — 0 m LU °°o CL In CID 'L LLoo IIIII Z 90 ow HZ J rn z J o w o > d M ODO ¢ O p p LL () „lz z m9 Cn ¢ wom L)wo 0 LL w rrr IIIII Z Z Zw — 7 W= O Z= a 0` Of Z 0°� 0 W fA -4 a W J LL LL¢w �_ LL IIIII � co �� — v; z () H J o w o a W c� w °0 000 (� „o ,s „ Z g n_3 IIIII z W W M�OF LLD_x� c`aI O O � C9 a ' �LL IIIII Lu Mw 0000 0 O = M Z o 0�0 IIIII � o Z i/i z 5 W Lid a QR o po opo° oo° pOoll�ll U IIIII o ILL ° W �55° 55° poo0 p o dp�000ppp� �pp0000 0 IIIII Z w ri v °O 00 Op °00 0°°0 Q 0oa0 ee�°IIIII — Q IIII=1. WIIM11111�11.p00 00 0 0 o Il Iw 0� 0 w OOp00 — U IIIII w 0) ° Op 00 z g 000 Z o rn rn 3LU j0 D00 ZO ��m Op W Q io Q 2 �w 0�0 W F- 00 W to 0 0 op `)W °0° °0 o z 0i?0 ZZ 0 o 0 v) o o w ° o0 z o 30 0 U) O p v ° (D Z J co Q 0M °O (A0 0 Z Lu Z_ 00000 00000 LL U V 0�0 0 p 0 00°0p 00000 �_ ¢ LL 0000°0000000000-0°0 W IL 00 00 00000g 000000 Z W 0000 00 CITY OF RALEIGH a LL CITY OF RALEIGH p° 0 0p0p o0 0$0°DDopooO a0 0 0 0 0 0 p p 0 o 0 0 0 o po 0 0000000 3008000000p 0 STANDARD DETAIL STANDARD DETAIL REVISIONS DATE: 8/1/18 NOT TO SCALE REVISIONS DATE: 811/18 NOT TO SCALE XVMOVO0 l E)NIISIX3 CONSTRUCTION STANDARD TEMPORARY ENTRANCE (SEDIMENT/SILT) FENCE SW-20.09 SW-20.01 I° %°oo°° 009 0 600000 u.i o OOo00 00 0o°��0° 1?00 Z w Z Y 0�000a 0 DO 0 Q lwiK¢LU Z cc, o000 n_ 0 00 ,,..pp� 00 0 LU s!QOF LL Z0. w U m W` �OQOQo� oQ,,o OO�� 0 �oo ° O �CiOa O-o LIL W = 2 ¢ W JO0 `N V°O 8 OOO a J W W H j =i ¢ O m LL Z LLZ OZ o 0000a0�°o Do° °° g� �0� 0 �� W Lu Wo �& W z zF a z LL" WCL oo 0o Q dl go p w 0 O W— ih o a X Q O .. 0 00 0 V1 W Z o O o °000 c0O"0 N 0 U) of F W ON [is do 090 O Q ...: ❑ 0 0 0 00 W. W . U F- I- 7 <o ❑ o a.°aa°oa°.pa ENO =_ ° p0� ❑❑ ❑� 00�0 000Q O Q �i ❑ eo ava° °•°°•°°o W Z 08 0 o Oo"oo .v•a. o (�A�i� °�Q ° 0°(�°o�o�°8�° 0 0 0°000�� -=0 ° ° ogo_Zo 217jr 000 o a ° oo_ 0 ° ��o ono `�a oo W a$¢ W _ Z o �0P4800 I— W �Q / 3 ¢ 2� 11= > w o >o w _ F- ILL m= I w w = vfV O J¢ LL _III o W LU 0 I- U U z a to Z d K W W W U) 0] W jOfn F O W J F 0 F-a-0Q LLaLLI �Q� 5OmwO O W wo O pWg WW� �LL Lid O ¢ V1JLL LL U>a mlZ1 w =03�> o� it oN� =gam UrYQ rnJ LL z O W U 0- LLF-p0Wo ,z j z m w O _ W g N W W d W F LL Z zQQWMJa J LL O 0�0�� U�C9 Oa(QK7 �O o = III 0 U m QUO g Z W w w F F O W W w U ¢pw00 ��= LLc�iwZ �a W = N O J¢ W O o =¢=x x W Z W H rA tr W Z (n W rG 11 0) O¢0 Q LL Co W (/� U' W UZJLLO LL3� (.7U� W �o 3. o - LL CITY OF RALEIGH LL0)O W Om2 ¢ W 0 0 CITY OF RALEIGH } = W Z o F ¢ w w¢ w ao J w W mo Dam STANDARD DETAIL w STANDARD DETAIL O H w O W W LL 2 O W� 0 O F O REVISIONS DATE: 8/1/18 NOTTOSCALE > Q 0 J REVISIONS DATE. •8/1/18 NOT TO SCALE �o�Ha U m �LLO CID U)) ZOO LU w N M BLOCK AND GRAVEL W W Of X STANDARD SILT DROP INLET PROTECTION Z 1: N FENCE OUTLET SW-20.14 SW-20.24 O O (" 5 O CV O CV CV 00 SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, INC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, INC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, INC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, INC 27603 CARC,, p�+ 9 O'5355 ''. • �:tiG I NEB•• •` This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 EROSION CONTROL DETAILS C8.02 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL 141FLda:71121[damE[NIk9IIi99111IXC3 NEW CONC. TO BL 3000 P51 EX15TING CONC, PI FL SEE 5-4 * 5-5 SAW CUT AND KLMOVL EX15TING PAVEMENT 4���I ,_o" I p N OTE5: I. 5ee City of Raleigh standards for trenches and pipe bedding { 5-4 C 5-5) for additional details. 2. Pavement cuts over 5'-0" In width Shall be reinforced to N.C.D.O-T. 5tandard5- 3. Pavement cuts Shall be made with an appropriate saw cut machine. 4. Pavement cuts within NCDOT ROW 5hall conform to the approved on site encroachment permit. BORE 1 1/8" DIA., 1'-0" ON CENTER ALONG CUT * DOWEL WI #4 BAR EXPANSION JOINT MATERIAL, MASTIC SEALANT, AND DOWEL ADHESIVE AS REQUIKLD BY NCDOT STANDARD SPECS. 5PLC5. UNDISTURBED SOIL NEW ASPHALT SURFACE COURSE EX15TING PAVEMENT 3" MINIMUM EX15TING PAVEMENT EXI5TING / 5UBGRADE 0, UNDISTURBED SOIL COMPACTED PILL IN G" LIFTS >/PIPE REFER TO 5-4 5-5 NOTES: I . IN NCDOT MAINTAINED ROADWAYS ENCROACHMENT PAVEMENT PATCH Rff_QUIF?;EMENTS SHALL TAKE PRECEDENCE. 2. THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT EDGE AND CUT WITH AN APPROPRIATE 5AWCUT MACHINE, 3. THE TRENCH 5UBGRADE MATERIAL SHALL BE DACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DEN5ITY OF AT LEAST 05% OF THAT OBTAINED BY COMPACTING A 5AMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-00 A5 MODIFIED 13Y NCDOT, 4. THE FINAL I' OF FILL SHALL CON515T OF ABC MATERIAL COMPACTED TO A DENSITY EQUAL To 100% OF THAT OBTAINED BY COMPACTING A 5AMPLE OF THE MATERIAL IN ACCORDANCE WITH AA5HTO T-80 A5 MOD11=1ED BY NCDOT. 5. THE ENTIRE TMICKNE55 AND VERTICAL EDGE OF CUT 5HALL BE TACKED, G. THE SAME DEPTH OF PAVEMENT MATERIAL WHICH EXISTS 5HALL BE REINSTALLED, BUT IN NO CASE SHALL THE A5PHALT BE LL55 THAN 3" THICK. 7. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY WITH A SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH LEVEL PATCH. 8. REFER TO CITY OF RALEIGH STANDARDS FOR TRENCHE5 AND PIPE BEDDING (5-4 *,5-5) FOR ADDITIONAL DEFAIL5. 9. NO HAND PATCHING ALLOWED. 10. PAVEMENT CUTS WITHIN N.CDOT ROW 5HALL CONFORM TO THE APPROVED ON SITE ENCROACHMENT PERMIT. NOTES: I . THE TRACER WIRE 5HALL BE CONTINUOUS TO THE GREATEST EXTENT P055115LE. WHERE JO.INT5 ARE NECE551TATEU IN THE WIRE, THE JOINTS 5HALL BE SECURELY EXTEND TRACER WIRE BONDED TOGETHER WITH AN APRROVE❑ INDUSTRIAL CRIMP CONNECTOR TO TO JUST BELOW PROVIDE ELECTRICAL CONTINUITY. CRIMP5 5HALL BE 51MILAR METAL, CLEAN OUT PLUG r[ 2. THE CLEANOUT AT THE RIGHT OF WAY AND OR EASEMENT SHALL 5ERVE AS THE TEST � PORT WITH THE TRACING WIRE BROUGHT UP OUT5IDE THE CLEANOUT A55EMBLY AND WRAPFEU AROUND THE 57ACK TWICE AT A DEPTH OF APPROXIMATELY 1 2" D J BELOW GRADE. 3, SPLICED CONNECTION5 5HALL SE ALLOWED BETWEEN THE MAIN LINE TRACER WIRE AND THE LATERAL TRACER WIRE, FINI5HED 4. FOR NEW 5EWER TAP5 ON EXISTING MAINS VOID OF ANY TRACER WIRE, PROVIDE AN GKADE ANODE FOR THE TRACING WIRE TERMINATION AT THE POINT OF THE NEW TAF ON THE ! .'p =•=�!=�• ,= EXISTING SEWER MAIN. PAVEMENT CURS �. • ' r IT LOOP TRACER WIRE QTWICE AROUND a CLEANOUT A55EM15LY a f TRACER WIRE -NO, 12 A z GAUGE 5CLID COPIER rn Z - BARE WIRE n a n MAIN TRACER WRE �<°n 70 r FOR. NEW MAIN Tit CAST IRON OR BRONZE CLEAN OUT PLUG C I. LP F11 Z y ?MnAIN. SEWER 70 N LATERAL NEW 5EtRVICE ON EXISTING MAIN- -PROVIDE MAGNESIUM ANODE (I LB MIN) REQUIRED WHERE NO TRACER WIRE 15 IN517ALLEU ON 5EWER MAIN C)C)(" 5 O CV O CV CV 00 CLEANOUT A55EMBLY Q FINISHED GRADE FINAL / UNDISTURBED SOIL BACKFILL 2 -D" INITIAL BACKFILL G" #G7 STONE ° a ° ° MINIMUM SIDE WHEN ROCK 15 G" O.D. OF PIPE 6" CLEARANCE ENCOUNTERED O.D. OF PIPE MAXIMUM SIDE CLEARANCE NOTES: 1. TRENCHE5 REQUIRING SHORING AND BRACING, DIMEN51ON5 SHALL BE TAKEN FROM THE IN51DE FACE OF THE SHORING AND BRACING. 2. NO ROCKS OK BOULDER5 4" OR LARGER TO BE U5ED IN INITIAL BACKFILL. 3. ALL BACKFILL MATERIAL 5HALL BE SUITABLE NATIVE MATERIAL. 4. BACKFILL5HALL 5L TAMPED IN G" LIFTS IN TRAFFIC AKLA5, 1 2" IN NON TRAFFIC AKLA5. 5. ACHIEVE 50% COMPACTION IN NON -TRAFFIC AREAS, AND 95% COMPACTION IN TRAFFIC AREAS. G. IF IN EA5EMENT 4" TOPSOIL, AND 1 2" CLEAN 5ELECT FILL MAY BE REQUIRED. 7. NO BOULDERS 8" IN DIAMETER OR GREATER ALLOWED IN FINAL BACKFILL. CITY OF KALLIGH DLPAKTMLNT OF PUBLIC UTILITIES TRENCH BOTTOM DIMLN510N5 t BACKFILLING REQUIREMENTS FOR DUCTILE IRON DWG. NO. REV1510N5 DATE REVISIONS DATE D.W.G. 9-3-99 5-4 RRH 3-30-00 LOCALLY AVAILABLE SIZES INTERCEPTORS CAPACITY (GAL.) 5LFAKATOK5 CAPACITY (GAL.) 300 1000 550 1200 750 1GOO loon 1200 1500 2000 2500 3000 4000 5000 0000 8000 NOTE5: 1. BAFFLE WALL LOCATED AT A D15TANCE FROM INLET WALL 23 TO /4 OF THE TOTAL LENGTH OF THE INTERCEPTOR OR 5EPARATOR A5 SHOWN ON DETAIL 5-40. BAFFLE WALLS LOCATED AT A D15TANCE APPROXIMATELY OF �/3 OF THE TOTAL LENGTH OF THE 5EPAKATOK A5 5HOWN ON DETAIL 5-40.01 . 2. EACH INTERCEPTOR OR StPAKATOK 511ALL HAVE INLET AND OUTLET TE5. THE OUTLET TEE 5HALL EXTEND 50% INTO THE LIQUID DEPTH. THE INLET TEE 5HALL EXTEND 25%u INTO THE 1JOUID DEPTH. INLET AND OUTLET TEES MU5T BE OPEN TO ALLOW THE COLLECTION OF F.O.G. 5AMPLE. 3. ACE55 OFENING5 OVER EACH COMPARTMENT WITHIN THE INTERCEPTOR OR 5EPARATOR5HALL BF 24 INCHE5 IN DIAMETER AND CONTAIN PICK HOLF5. ALL COVERS 5HALL BE CONSTRUCTED OF CA5T IRON OR toU.fvALENT TRAFFIC BFAPJNG MATERIAL. MANHOLE COVtK5 MUST EXTEND TO FINISH GRADE AND BE INSTALLED TO EXCLUDE THE ENTRANCE Of 5TORMWATER INTO THE iNTEKCPPTOR OR SEPARATOR. 4. FULL 517F DUAL SWEEP CLEANOUT5 SHALL BE I45TALLED ON THE INLET AND OUTLET 51DF5 OF THE INTERCEPTOR OR 5EPARATOK. 5. INTFRCEPTOR5 AND 5FPARATOR5 MUST BE VENTED IN ACCORDANCE WITH THE NC 5TATF FLLJMBING CODE. G. CONCRETE: 4000 P51 @ 28 DAYS. 7. DE5fGN: ACI 3 I b BUILDING CODE A5TM C I G 3-OG FOR GREA5f INTERCEFTOR5 A5TM C913-02 FOR WATER AND WA5TEWATER 5TRUCTURE5 A5TM C890-OG FOR MINIMAL STRUCTURAL DE51GN LOADING b. INTERCEPTORS AND arAKATOR5 5HALL BE DE5iGNED TO WITHSTAND AN H 20 WHEEL LOAD. 9. INTERCEPTORS OR SEPARATORS MADE Of POLYETHYLENE OR FIBEKGLA55 5HALL INCLUDE A MINIMUM 12,OG0 P51 TENSILE STRENGTH, 19.000 P51 FLEXURAL 5TRFJNGTi. AND 800,000 P51 FEXURAL MODULU5. 10. ALL INTERCEPTOK5 AND 5tPARATOK5 5HALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTUREK5 SPECIFICATIONS. FINISHED GKADL FINAL BACKFILL / UNDISTURBED 501L INITIAL BACKFILL SPRING LINE .'-. / #G7 STONE HAUNCITL a° a ° o PIPE GRADE °o °gym aO° 4" BEDDING TAMP WELL UNDER MINIMUM SIDE BOTTOM HALF OF PIPE G" O.D. OF FIFE 6" �� CLEARANCE TYPICAL TRENCH BOTTOM DIMEN51ON5 FOR 5DR 35 PVC GRAVITY PIPE NOTES: I . FOR TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN FROM THE INSIDE FACL OF THE SHORING AND BRACING. 2. NO ROCKS OK BOULDERS 4" OR LARGERTO BE USED IN INITIAL BACKFILL. 3. ALL BACKFILL MATERIAL 5HALL BE SUITABLE NATIVE MATERIAL. 4. BACKFILL 5HALL BE TAMPED IN G" LIFTS IN TRAFFIC AKLA5, 1 2" IN NON -TRAFFIC AKLA5. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIL5 TRENCH BOTTOM DIMLN51ON5 AND BACKFILNNG REQUIREMENTS FOR PVC GRAVITY 5EWER MAIN DWG. NO. REVISIONS I DATE I REVISIONS I DATE 5-5TO NOTES 3-1-87 I D.W.C. 9-3-99 7-2-82 I RRH -30-00 8" W/ G/5/4" BOOT 8" C24' SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 0*4 a)O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION PROJECT NUMBER: 21901 1 SANITARY SEWER DETAILS C e03 Construction Documents NEW CONC. TO BE EXISTING 3000 P51 CONC. - 5AW CUT AND KLMOVL EXISTING PAVEMENT I _0, TYP, . NEW ASPHALT SURFACE COARSE 3" MINIMJM EX15TING PAVEMENT EXISTING PAVEMENT NL 1DC 12 MIN U[:r' as°� BORE I 1/8" DIA., I'-O° 2" BW ELOEXISTING EXISTING 5UBCRADE O° ... ON CENTER ALONG CUT # G" COMPACTED NO. DOWEL W/ #4 BAR G7 STONE -O" TyP' TYP' `-UNDISTURBED EXPANSION JOINT MATERIAL, COMPACTED SOIL BACKFILL, TAMPED IN MASTIC SEALANT, AND DOWEL FILL IN 6" LIFTS ADHE51VE AS REQUIRED BY G." LIFTS NCDOT STANDARD SPECS. PIPE FIFE UNDISTURBED SOIL REH> R TO W 3 SEE W-3 NOTES: 1. 5EE CITY OF RALEIGH 5TANDARD5 7ORTRENCHE5 AND PIPE BEDDING W-3 FOR ADDITIONAL DETAILS 2, PAVEMENT CUTS WITHIN NCDOT ROWS ALL CONFORM TO THE APPROVED ON SITE ENCKOACHMFNT PERMIT. 3. THE PAVEMENT CUT 5HALL BE DEFINED BY A 5TKAIGHT EDGE AND. CUT WITH AN APPROVED 5AW'CUT MACHINE. 4. THE TRENCH 5UBGKADE MATEMALSHALL BE BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DEN5ITY OF AT LEA5T 95% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AA5HTO T-99 A5 MODIFIED BY NCDOT. 5. THE FINAL G" OF FILL 5HALL CONSIST OF ABC MATERAIL COMPACTED TO A DENSITY EQUAL TO 1 DO% OF THAT OBTAINED BY COMPACTING A 5AMPLE OF THE MATERIAL IN ACCORDANCE WITH AA5HTO T-bO A5 MODIFIED BY NCDOT. TEE INTERSECTION NOTES: I . THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT LOGE AND CUT WITH AN APPROPRIATE SAW CUT MACHINE. 2. THE TRENCH 5U8GRADE MATERIAL SHALL BE BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DENSITY OF AT LEAST 95% Of THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-99 A5 MODIFIED BY NCDOT. 3. THE FINAL 1' OF FILL SHALL CON515T Of ABC MATERIAL COMPACTED TO A DENSITY EQUAL TO 1 00% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THL MATERIAL IN ACCORDANCE WITH AA5HTO T-60 A5 MODIFIED BY NCDOT. 4. THE ENTIRE THICKNESS/ VERTICAL EDGE OF CUT SHALL BE TACKED. 5. THE SAME DEPTH OF PAV}rIv1ENT MATERIAL WHICH EXISTS SHALL BE RLIN5TALLED, BUT IN NO CASE SHALL THE ASPHALT BE LESS THAN 3" THICK. G. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY WITH A SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH LEVEL PATCH, 7. REFER TO CITY OF PALEIGH STANDARDS FOR TRENCHES AND PIPI= BEDDING, W-3. FOR ADDITIONAL DETAILS. 8. NO HAND PATCHING ALLOWED. 9. PAVEMENT CUTS WITHIN NCDOT ROW SHALL CONFORM TO THI< APPROVED ON SITE ENCROACHMENT PERMIT. THRUST BLOCKING C � C9 P o Fcl n o N THRU5T BLOCK z AREA S 70 y z D CD W o 6' � n - O O r C -'I NOTES: a n rn 1. CONCRETE 51ALL 5E 3000 751 G) 2. CONCKETE 5HALL NOT CONTACT 130LT5 ORENDS OF r = O G� MECHANICAL JOINT FITTINGS. U < � 3. TKENCHE5 SHALL CONFORM TO STANDARD DETAIL W-3. 4. SEE STANDARD THRUST BLOCK TABLES, W-10 THRU W-1 1, FOR AREA OF CONCRETE REQUIRED. 5, ALL 5END5 AND INTERSECTIONS 5HALL HAVE CONCRETE THRUST BLOCKING. b b 0� O TYPICAL NOTES: 1)-ALL EXPOSED PIPING AND FITTINGS TO BE GALVANIZED WITH EXCEPTION OF STORZ CONNECTION 2)-40' MAX. FROM FDC TO FIRE APPARATUS ACCESS (DRIVEWAY) 3)-FOR NFPA 13R SYSTEMS (2 1/2" RISER AND SMALLER) SINGLE FDC W/ RALEIGH THREADS (3.340 X 6 SHARPE V FORM) 4)-WHEN BUILDING HT. IS GREATER THAN 200' USE RAL. SIAMESE 5)-AN APPROVED CONNECTION (TAPPING NOT APPROVED) `I b. aba a:d.'�4. 4d 5" STORZ CONNECTION 30 DEGREE FIXED (NON -SWIVEL) THREADED NIPPLE W/ CAP SECURED W/ CHAIN GUARDIAN MODEL 6625 RAL. (4") OR MODEL 6628 RAL (6") OR EQUAL STABILIZE PIPE WITH 2' X 2' X 6" CONC. PADL BITUMINOUS COATING APPLIED TO GALVANIZED�� �LLw MINIMUM" (HOT DIP) GALV. 01 -J�ncn< RODS WITH BITUMINOUS COATING m 0 ON BOLTS AND NUTS. TO SYSTEM DEADMAN RESTRAINT PER PUBLIC UTLITIES THRUST BLOCKING PER COR DETAIL #W-7 PUBLIC UTILITIES GUIDE W-9 QUARTER TURN ¢ BALL VALVE o r TM Mw O O (_ w2c- m IL GRADE BALL DRIP IN GRAVEL WRAP GRAVEL IN FILTER FABRIC (FX55, OR EQUAL) CITY OF RALEIGH FIRE DEPARTMENT DESCRIPTION: REVISIONS: DATE: DRAWING NO. FIRE PROTEGPON DIVISION YARD FDC DETAIL REQUIREMENTS 5-1 06 IS. e FP-15 310 WEST MARTIN ST. RALEIGH, NC 27602 0 O I-0 O CV O CN CV 00 UNDISTURBED 501 L O.D. OF PIPE �� MINIMUM 51DE I G" OF #G7 STONE WHEN I G G' I CLEARANCE ROCK OR WATER 15 FS � - ENCOUNTERED NOTES: I . TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BL TAKEN FROM THE IN51DE FACE OF: THE SHORING AND BRACING. 2. NO R.00K5 OR B0ULDER5 4" OR LAKGEP TO SE USED IN BACKFILL. 3. ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL. 4. BACKFILL SHALL 13E TAMPED IN G" LIFT5. 5. ACHIEVE 95% COMPACTION IN BACKFILL. GATE / TAPPING VALVE A a a - 4 fl O D o D.. 4 4 07 p Oi _ o0 ..4 A A TOP VIEW 3000 P51 SOLID CONCRETE SHALL BE USED AS FOOTING FOR DUCTILE IRON PIPE. VALVE FLANGE M.J. PETTING P Q - .4 a� o 0 r,IAIIJ TAPPING SLEEVE 51DL VILW NOTES: 1. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTI N G5. 2. 5EE STANDARD REACTION BLOCK CITY OF RALEIGH TABLES, W-1 O AND W-I I FOR AREA OF DEPARTMENT Of FUBUC UTILITIL5 CONCRETE REQUIRED. 4" - 24" 5TANDARD TAPPING SLEEVE AND VALVE A55EMDLY DWG. NO. REVISIONS I DATE I REVISIONS DATE W- 14 Y.C.A, 1 2-3 1 -9 I KRIT 3-3 1-00 D.W.C. 9-7-59 1 J.F.5. 11 1-1-10 PROPERTY MINIMUM 3G" HOKWONTAL CLEARANCE LINE FROM ANY OBJECT. FIRE HYDRANT, PUMPER NOZZLE TO BL POINTED TOWARDS FIRE TRUCK ACCESS. TRAFFIC FLANGE BETWEEN 2" 6" ABOVE GRADE ]-I SIDEWALK CURB AND GUTTER �6 � �. PAVEMENT VALVE BOX G" GATE VALVE CONC. THRUST N COMPACTED BACKFILL / BLOCK (TAMPED IN G" LIFTS) f/ - A.. G" MIN. BRANCH PIPE _ RESTRAINING GLANDS MAIN E-I'-3"x I'-3"x 4" THICK RESTRAINING GLANDS 7 CU. FT. CRUSHED STONE MIN. UNDISTURBED EARTH. NOTES: 1. FIRE HYDRANT SHALL BE A5 MANUFACTURED: MUELLER. AMERICAN DARLING. KENNFDY, M4H, WATEKOU5, CLOW, EA5T JORDAN IRON WORKS. OK U5 FIFE. 2. BRANCH PIPE 511ALL BE DUCTILE IRON AMA C 15b-9C 3. G" GATE VALVE 5HALL BE AWWA C500-8G OPEN LEFT 4. STEEL ROD5 AND BOLT5 5HALL BE A" HOT DIPPED GALVANIZED 5. FIRE HYDRANTS WILL BE INSTALLED IN TRUE VERTICAL P051TION KOD5 5HALL NOT BE COUPLED MORE THAN ONCE. IF THE LENGTH FROM THE VALVE TO THE HYDRANT EXCEEDS 20THEN A MI=CHANICAL RESTRAINING GLAND WITH A KEBAfK CAGE 5HALL BE INSTALLED NO MOPE THAN 10' FROM HYDRANT AND POURED IN CONCRETE. FIRE HYDRANT5 TO BE LOCATED IN ROW OR 2 FOOT EA5EMENT ADJACENT TO ROW ANYTIME SITE WORK, CONSTRUCTION, ROAD WORK, OR ANY OTHER WORK CHANGES THE GRADE OF THE FIRE CITY OF RALEIGH HYDRANT, THE PERSON RE5PON51BLE FOR THE WORK 15 RE51`011515LE FOR DEPARTMENT OF PUBLIC UTILITIES ADJUSTING THE PIKE HYDRANT TO STAY WITHIN COMPLIANCE. rJ`TANDARD FIRE I�YDRANT INSTALLATION DETAIL DWG. NO, REVI510115 DATE REV151ON5 A6t3 4-6-OQ- PAP W-4 ©HL V 14108 APPROVED METHOD FOP. EYTEN51ON OF VALVE SOX NOTE: 2'x 2'r G" CONCRETE PAD REQUIRED ON ALL VALVF5. NO FRECA5T CONCRETE DOUGHNUT ALLOWED. 5 112'-5 515 I I14"-I I" SEE STANDARD W-18 FOR COVER Dff7AIL5. 1 5TANDAKD VALVE I � BOX TOP SECTION TO Y� 2'-r� DOMESTIC BL SLIDE SECTION CASTING FINAL PAVEMENT P, COURSE . .n VALVE BOX COVER CONCRETE , PAD VALVE BOX U5E 5" 501L PIPE FOR EXTENSIONS TAMPED- BACKFILL VALVE WATER 0 0 MAIN 5TAD-IN C.I. OR D.I. : •. " . ' FIFL GASKET TAMPED .:"_;•..: "''." : :; ' BACKFILL NOTF5: 1 I VALVE BOX NOT TO CONTACT WATER MAIN 2) ALL TKAFFIC CA5TING5 MUST BE CLA55 35 OK GREATER. 3) FOR ANY VALVF5 OVER 1 O' DEEP, A VALVE 5TEM EXTEN510N MUST BE U5ED TO. BRING TO A DEPTH OF NO MOKE THAN 5', EXTEN510N MUI BE A MINIMUM OF 1' 501-[D 5TOcr. STANDARD VALVE BOX 4) TOTAL VALVE BOX WEIGHT: MINIMUM DF 85 LB5. BOTTOM SECTION SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda � Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 CAR(-,, '. • O ES r _ JE- 9r•i 0 35 355 '. • �.tiG I NE�e' 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 WATER DETAILS C so4 Construction Documents a: I v I 4 o. Q z �z J_ w. TEE/ w ,40 IRRIGATION oCl DOMESTIC BACKFLOW a m SPLIT AND SERVICE VALVE NEW OR EXISTING WHEN REQUIRED d ^ U a CURB 5TOP v METER DOMESTIC 0 IRRIGATION METER LINE I I NEW CURB STOP IN CURB STOP BOX APPROVED RP BACKFLOW ASSEMBLY. NOTES: 1. IRRIGATION METER SHALL BE LOCATED ON THE 51DE OF DOMESTIC METER WITH INCREASING ADDRE55E5. 2. THE BACKFLOW SHALL BE INSTALLED NO MORE THAN I O' FROM THE METER IN A VISIBLE LOCATION. 3. BACKFLOW RI5ER/5TANDPIPE SHALL BE OF COPPER OR BRA55. 3. THE RP RELIEF VALVE SHALL BE A MINIMUM OF 1 2" ABOVE ANY MATERIAL (MULCH INCLUDED) OR GRADE. 4. A SERVICE VALVE 15 REQUIRED AFTER THE METER BUT BEFORE THE BACKFLOW ASSEMBLY FOR MAINTENANCE AND REPLACEMENT PURPOSES. 5. THE INSTALLATION MUST AL50 MEET ALL CODE REQUIREMENTS PER THE NC PLUMBING CODE. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES IRRIGATION TAP ON NEW AND EXI5TING SERVICES DWG. NO. 1 REV151ON5 DATE I REVISIONS I DATE W-35 RRH 3-31-00 D.H.L. G-18-08 ABB -10-04 1 J.1".5. 10/25 1 O 28, TO RISER ROOM 18 Y2" MAXIMUM ELECTRIC SUPERVISORY CONTROL VALVE SWITCH (MUST FACE UPWARD) WALL SLEEVE SET WALL SCREW 4 ° o Z ° Z1Siltll GATE VALVE � O ---------- 1SZ1Si Z d° (SLO 5" w LOCK ° WALL SLEEVE a 5/6" STAINLESS ° d ° 0 iu STEEL CHAIN ° v z (LOCK PROVIDED ° 0 a BY TOWN) d ° G1 O Q M ° W > ° ° ° 0 ° d 00 ° ° ° d ° GRADE LINE ° FLOOR ° ° °° ° °° I I 1=1 1-1 11-1 11=1 I I I, �,I I II I II I Il=„III FROM WATER MAIN 1 -III-III-I l ll i ll l ll l ll l -II WALL MOUNTED POST INDICATOR VALVE N.T.S. CA5T DATE U PLAN VIEW BOTTOM VIEW NOTE I - "WATER" LETTERING MUST BE 1 " RAIS[D (RECESSED FLU511) 5LCTION VIEW NOTE 2 VALVE COVLK SHALL BE DOML5TICALLY CAST. NOTE 3 - COVER MU5T HAVE A MINIMUM WEIGHT OF 25 POUND5. NOTE 4 - COVER MUST BE CLA55 35 OR GREATER. NOT[ 5 COVEK MU5T MELT OK EXCEED AA511TO H-20 LOAD 9fQUIREMENTS, I V . A. MLTLK a I A55EMBLYI P' Z Q .a APPROPRIATE BACKFLOW °' ' a PKLVLNTION A55EMBLY 4w. (ABOVE GROUND ONLY) 0 4 o I DOME5TIC LINE a APPKOPKIATL FIKL LINE BACKFLOW PRE. A55EM. (ABOVL GROUND ONLY) n FIRE LINE ' MAIN a Q I I p IRRIGATION LINE � FDC IF R APPLICABLE METER O REDllC1 D PRE5URP A55EMBLY W A55EMBLY (ABOVE GROUND ONLY) 1 . 5EKVICE TAP5 FOR 2" AND 5MALLER DOMESTIC 5ERVICE5 MAY BE BY CORPORATION COCKS. LARGER 5ERVICE5 WILL REQUIRE A TEL AND GATE VALVE OR TAPPING 5LE[VE AND VALVE A55LMBLY AND 90° BEND. 2. DOMESTIC 5ERVICETAP5 SHALL BE ALLOWED ONLY ON G" OR LARGER FIRE LINE5 BEFORE THE BACKFLOW A55LM13LY. 3. ONE DOMESTIC TAP PER FIRE UN[ ON 5TREET 51DE OF: BACKFLOW. 4. FIRE LINE SHALL HAVE A FIRE HYDRANT OR BLOW OFF A55EMBLY AT IT5 END TO FACILITATE FLU51HING WHEN NEEDED. 5. IRRIGATION METER 5HALL BE LOCATED ON THE 51DL OF DOMESTIC METER WITH INCREA5ING ADDRESSES. G. THE BACKFLOW SHALL BL INSTALLLD NO MORE THAN 1 0' FKOM THE MLTLK IN A V1515LL LOCATION. 7. DOME5TIC'/IRRIGATION BACKFLOW RI5ER/5TANDPIPE SHALL BE OF COPPER OR BRA55. 8. THE KP RELIEF VALVE SHALL BL A MINIMUM OF 1 2" ABOVE ANY MATERIAL (MULCH INCLUDED) OR GRADE. 9. A SERVICE VALVE 15 REQUIRED AFTER THE METER BUT BEFORE THE BACKFLOW A55EMBLY FOP, MAINTENANCE AND REPLACEMENT PURPOSE5. 10. THE INSTALLATION MUST AL50 MEET ALL CODE REQUIKEMLNT5 PER THE NC PLUMBING CODE. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIE5 FIRE, DOME5TIC � IRRIGATION 07TION5 SCHEMATIC DWG. NOJ REVISIONS I DATE 1 KEV1510N5 DATE W-34 D.w.c.I 11-18-99 A.B.B. 7-10-04 RRH 3-3 1 -oo I D. H . L. G/ 18/08 4'-0" G" MIN. LIFTING HOLES rn'• / TYP 4X 25" 12'' 3'-0" 35" TYP SHAPE TRAFFIC RATED ACCESS DOGHOUSE DOOR W/ SLAM LOCK CAST IN TOP G" MIN. 1 2"W x 18"H DOGHOUSE WEIGHT: 2,900 lb5. NOTE5: 1) REINFORCEMENT: #4 @ G" OCEW 2) CONCRETE: 4,000 PSI @ 28 DAYS 3) G" OF #G7 STONE SHALL BE PLACED IN CITY OF RALEIGH BOTTOM OF VAULT DEPARTMENT OF PUBLIC UTILITIES 4) METER FLANGE SHALL BE PLACED 42 " BELOW FINISHED GRADE TYPICAL 4" WATER METER VAULT DWG. NO. REVISIONS DATE REVISIONS DATE W-32 A.B.B. 8-2G-04 D.H.L. G-I8-0,5 ++ ++ ++++++ +++++ +++++ +++++ +++++ ALUMINUM LID + + + O N mW� U� ww Q z g WATER MAIN Z p(2 N m�Y) J LUo oJU wU-J lu m� OD�HJ =� H � J ° UQ] W Z L NIPPLE w q w Q0 z JJ � z tu m �l Q > Z w w tu > tu- m �� w Q U °°� m p O H p �w �N Q�X =Om O > 06)UJ 0o zip wUJ CL gwo Q p \ U wm z wp H W = I- D Z¢ QO X Q j U Z U- JU-i Z Q0 J10 ,61 n U- WJ 0OZ �u O o � wwLU LU z 0L zQ UJ :j p U- U Z N ct) KN� G N UJ :�00 0z 0 pQCDI u)Q) ZZ =amm rom > Q � 0 CU CITY OF RALEIGH _ CZ E w o DEPARTMENT OF PUBLIC UTILITIES mo TYPICAL 4"- 5" DOMESTIC WATER METER Q 13YPA55 1 N 5TALLATI O N DWG. NO. REVISIONS DATE REVISIONS DATE W-29 D.W.0 11-IS-9 D.H.L. G/IS/OS A.B.B. 8-30-04 J.P.S. 1 1 -4-10 SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. @ Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION PROJECT NUMBER: 21901 1 WATER DETAILS C 005 Construction Documents CONSTRUCTION SPECIFICATIONS GENERAL NOTES 1. PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION. 2. PRIOR TO ANY CONSTRUCTION OR PLACEMENT OF ANY BACKFILL, THE ONSITE GEOTECHNICAL ENGINEER SHALL INSPECT THE EXCAVATION AREA FOR THE UNDERGROUND SCM WITHIN THIS AREA TO ASSESS WHETHER SUITABLE SOILS EXIST AT THE SUBGRADE LEVEL. IF THE CONTRACTOR CONSTRUCTS AND COVERS UP THE UNDERGROUND SCM PRIOR TO INSPECTION, THEN THIS AREA SHALL BE UNCOVERED AND TESTED (TO THE ENGINEER'S AND OWNER'S APPROVAL) AT THE CONTRACTOR'S EXPENSE. 3. THE FACILITY SHALL NOT BE USED AS A TEMPORARY EROSION CONTROL DEVICE (I.E. SEDIMENT TRAP OR SEDIMENT BASIN) DURING CONSTRUCTION. 4. PRIOR TO PLACING STORMFILTER CARTRIDGES WITHIN THE UNDERGROUND SYSTEM, THE CONTRACTOR SHALL REQUEST AN ONSITE MEETING WITH THE DESIGN ENGINEER AND THE EROSION CONTROL INSPECTOR TO ENSURE THE UPSTREAM DRAINAGE AREA IS COMPLETELY STABILIZED (I.E. GOOD VEGETATIVE COVER). IF THE CONTRACTOR DECIDES TO PLACE THE STORMFILTER CARTRIDGES PRIOR TO APPROVAL FROM THE DESIGN ENGINEER AND THE EROSION CONTROL INSPECTOR, THEN THE CONTRACTOR SHALL EXCAVATE/REPLACE, AS NECESSARY, THE COMPONENTS NEEDED FOR THE SYSTEM TO FUNCTION PROPERLY AT HIS / HER EXPENSE SHOULD THE STORMFILTER CARTRIDGES NOT FUNCTION PROPERLY (I.E. WILL NOT DRAIN DUE TO SEDIMENT DEPOSITION) DUE TO AN UNSTABILIZED UPSTREAM DRAINAGE AREA. 5. ONCE CONSTRUCTED, THE STORMFILTER CARTRIDGES SHALL NOT RECEIVE STORMWATER RUNOFF UNTILTHE ENTIRE CONTRIBUTING DRAINAGE AREA TO THE UNDERGROUND SYSTEM HAS BEEN COMPLETELY STABILIZED AND SITE CONSTRUCTION IS COMPLETE. 6. ALL COMPONENTS OF THE UNDERGROUND SCM SYSTEM (JOINT/ RISER CONNECTIONS, ENDCAPS, ACCESS MANHOLES, ETC.) SHALL BE DESIGNED BY OTHERS. ANY VARIATIONS OR CHANGES MADE FROM THESE SPECIFICATIONS AND DRAWINGS DURING THE ORDERING AND/ OR INSTALLATION OF ALL COMPONENTS MUST BE APPROVED BY THE DESIGN ENGINEER. THE STRUCTURAL DESIGN OF THE UNDERGROUND SCM, ALONG WITH ITS ASSUMPTIONS, IS ALSO BY OTHERS. THE JOHN R. McADAMS COMPANY, INC. AND ITS EMPLOYEES ASSUME NO LIABILITY WITH RESPECT TO ANY ASPECT OF THE STRUCTURAL DESIGN FOR THE UNDERGROUND SCM SYSTEM. 7. ALL PIPE/RISER CONNECTIONS AND JOINTS ASSOCIATED WITH THE STORM FILTER SYSTEM AND UNDERGROUND DETENTION PIPE SHALL BE WATER TIGHT. THE MECHANISM FOR ACHIEVING THIS SHALL BE SUBMITTED TO THE DESIGN ENGINEER FOR REVIEW. 8. THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE SAND FILTER SYSTEM SITE. IT IS ANTICIPATED THAT PUMPING WILL BE NECESSARY IN THE EXCAVATION AREAS. DURING PLACEMENT OF FILL WITHIN THIS AREA (OR OTHER AREAS AS NECESSARY), THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ADHERE TO ALL CURRENT OSHA REGULATIONS FOR CONFINED SPACE ENTRY AND PROVIDE SUCH DURING ENGINEER WALK-THROUGH/INSPECTION. 10. ALL PIPE PENETRATIONS THROUGH A CONCRETE OR CMP STRUCTURE (I.E. STORMFILTER CARTRIDGE / DETENTION SYSTEM, STORM DRAINAGE MANHOLES, ETC.) SHALL BE MADE WATERTIGHT USING NON -SHRINK CEMENTIOUS GROUT. 11. ACCESS MANHOLES SHALL INCLUDE LADDERS OR MANHOLE STEPS. IF, AT ANY ACCESS POINT, MANHOLE STEPS WOULD RESULT IN A 3" OR GREATER OFFSET, A LADDER SHALL BE PROVIDED. AS SUCH, A LADDER SHALL BE REQUIRED AT ALL MANHOLE ACCESS POINTS TO THE STORMFILTER VAULT. ALL LADDERS SHALL INCLUDE AN EXTENDING AND RETRACTING SECTION THAT ALLOWS THE LADDER TO BE EXTENDED ABOVE THE ACCESS LID TO FACILITATE SAFE INGRESS AND EGRESS TO/FROM A STANDING POSITION. FOUNDATION NOTES 1. ONCE THE EXCAVATION IS COMPLETE AND PRIOR TO INSTALLATION OF THE UNDERGROUND SCM SYSTEM, THE ONSITE GEOTECHNICAL ENGINEEER SHALL VERIFY THE BEARING CAPACITY OF THE UNDERLYING SOILS TO SERVE AS A FOUNDATION FOR THE UNDERGROUND SCM SYSTEM. IF THE ONSITE GEOTECHNICAL ENGINEER DEEMS THE FOUNDATION SOILS AS UNSUITABLE, THEN THE UNSUITABLE MATERIAL SHOULD BE REMOVED DOWN TO A SUITABLE DEPTH AND THEN BUILT BACK UP TO THE CORRECT ELEVATION WITH A COMPACTED BACKFILL MATERIAL THAT IS APPROVED BY THE ONSITE GEOTECHNICAL ENGINEER. THE APPROVED BACKFILL MATERIAL SHOULD HAVE A GRADATION THAT WILL NOT ALLOW THE MIGRATION OF FINES, WHICH COULD CAUSE SETTLEMENT OF THE UNDERGROUND SCM SYSTEM. IF NECESSARY, A GEOTEXTILE FABRIC CAN BE USED TO SEPARATE THE UNDERLYING SOILS AND THE BACKFILL MATERIAL. THIS GEOTEXTILE FABRIC (IF USED) IS TO BE SPECIFIED BY THE GEOTECHNICAL ENGINEER. 2. IF THE FOUNDATION SUBGRADE WILL BE EXPOSED FOR AN EXTENDED PERIOD DURING CONSTRUCTION, THEN IT SHOULD BE GRADED TO A SLIGHT SLOPE SUCH THAT SATURATION OF THE SUBGRADE DOES NOT OCCUR. 3. THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC. NEEDED FOR REMOVAL OF WATER FROM THE EXCAVATION. IT IS BEST TO BEGIN THE CONSTRUCTION OF THE SAND FILTER/DETENTION SYSTEMS AT THE DOWNSTREAM END WITH THE OUTLET ALREADY CONSTRUCTED TO ALLOW A ROUTE FOR WATER TO ESCAPE. 4. THE ONSITE GEOTECHNICAL ENGINEER SHALL DETERMINE IF FOUNDATION DRAINS ARE REQUIRED FOR THE UNDERGROUND SCM SYSTEM. THE DESIGN ENGINEER SHALL BE NOTIFIED FOLLOWING THIS DETERMINATION. IF REQUIRED, THE FOUNDATION DRAINS ARE TO BE DESIGNED ENTIRELY BY THE ONSITE GEOTECHINCAL ENGINEER. THE FOUNDATION DRAIN SYSTEMS SHALL TIE TO THE NEAREST STORM SEWER INLET / JUNCTION BOX WITH INVERT LOWER THAN THE INVERT OF THE FOUNDATION DRAIN. FOUNDATION DRAIN SYSTEM SHALL NOT TIE INTO THE UNDERGROUND SCM AT ANY POINT. BEDDING NOTES 1. THE EXCAVATION SUB GRADE MUST BE TRANSIT LEVEL. 2. THE EXCAVATION PIT SHALL BE LINED (ON THE BOTTOM AND ALL FOUR SIDES) WITH A NON -WOVEN GEO-TEXTILE (GEOTEX 401 OR APPROVED EQUIVALENT). THE ONSITE GEOTECHNICAL ENGINEER SHALL APPROVE FABRIC FOR USE. 3. THE SUBGRADE FOR THE DETENTION SYSTEM CAN BE A CONCRETE SLAB, OR CLEAN GRANULAR MATERIAL WITH A MAXIMUM AGGREGATE SIZE OF 3/4". THE BEDDING SHALL BE FREE FROM ROCK FORMATIONS, PROTRUDING STONES, FROZEN LUMPS, ROOTS, AND OTHER FOREIGN MATERIAL. 4. PREPARE THE SUBGRADE PER THE ONSITE GEOTECHNICAL ENGINEER'S DIRECTION (APPROXIMATELY 5-6" BELOW GRADE ON WHICH SLAB WILL SET). THE BEDDING MATERIAL SHOULD BE GRADED SUCH THAT A SMOOTH UNIFORM GRADE IS ESTABLISHED TO ALLOW FOR OPTIMUM PLACEMENT OF THE SAND FILTER. 5. THE SUBGRADE MUST SUPPORT THE DETENTION SYSTEM WITHOUT DIFFERENTIAL SETTLEMENT BETWEEN PIECES. 6. IF CONSTRUCTION EQUIPMENT WILL BE OPERATING FOR AN EXTENDED PERIOD OF TIME ON THE BEDDING, THEN THE APPROPRIATE MEASURES (E.G. STIFF GEOGRID, ETC.) SHALL BE TAKEN TO ENSURE THE INTEGRITY OF THE BEDDING IS NOT COMPROMISED. STORMWATER SYSTEM MATERIAL SPECIFICATIONS 1. THE UNDERGROUND SCM UNITS ARE TO BE DESIGNED BY OTHERS. ANY CHANGES TO THE APPROVED PLANS SHALL BE PROVIDED TO THE DESIGN ENGINEER PRIOR TO INSTALLATION FOR REVIEW. 2. ACCESS RISERS SHALL BE INSTALLED PER MANUFACTURE SPECIFICATIONS. ACCESS STEPS / LADDERS SHALL BE ATTACHED TO THE RISERS TO ALLOW FOR ACCESS INTO THE UNDERGROUND SCM SYSTEM. 3. DRAWDOWN OF THE STORMFILTER CARTRIDGE AREA AND DETENTION SYSTEMS IS VIA AN 6" 0 PLUG VALVE. THE VALVES SHALL BE A M&H STYLE 1820 X-CENTRIC VALVE OR ENGINEER APPROVED EQUIVALENT. THIS VALVE IS IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM INSIDE THE SEDIMENTATION AND DETENTION SYSTEMS VIA A HANDWHEEL (SEE DETAIL SHEET SW-2). THE CONTRACTOR SHALL PROVIDE A REMOVABLE VALVE WRENCH WITH A HANDWHEEL ON TOP FOR OPERATION OF THE 6" 0 PLUG VALVE. 4. THE RCP OUTLET BARREL SHALL BE CLASS III RCP, MODIFIED BELL AND SPIGOT, MEETING THE REQUIREMENTS OF ASTM C76-LATEST. THE PIPE SHALL HAVE CONFINED O-RING RUBBER GASKETJOINTS MEETING ASTM C-443-LATEST. THE PIPE JOINTS SHALL BE TYPE R-4. 5. GEOTEXTILE FABRIC FOR THE OUTLET BARREL JOINTS SHALL BE MIRAFI 18ON OR ENGINEER APPROVED EQUAL (NON -WOVEN FABRIC). THE ONSITE GEOTECHNICAL ENGINEER SHALL APPROVE FABRIC FOR USE. 6. ALL POURED CONCRETE SHALL BE MINIMUM 3000 PSI (28 DAY) UNLESS OTHERWISE NOTED. 7. THE CONTRACTOR SHALL INSTALL THE UNDERGROUND SCM UNITS PER MANUFACTURERS' SPECIFICATIONS. CONTRACTOR TO PROVIDE A LETTER FROM MATERIAL SUPPLIER(S) STATING MATERIALS MEET THE SPECIFIED STANDARDS PRIOR TO INSTALLATION. BACKFILL MATERIAL NOTES 1. THE ON -SITE GEOTECHNICAL ENGINEER SHALL SPECIFY THE BACKFILL MATERIAL FOR THE UNDERGROUND SCM SYSTEM. 2. THE BACKFILL MATERIAL SHOULD BE FREE OF ROCKS, FROZEN LUMPS, AND OTHER FOREIGN MATTER THAT COULD CAUSE HARD SPOTS WITHIN THE BACKFILL MATERIAL, OR THAT COULD DECOMPOSE AND CREATE VOIDS. 3. HIGHLY PLASTIC SILTS, HIGHLY PLASTIC CLAYS, ORGANIC SILTS, ORGANIC CLAYS, AND PEATS SHOULD NOT BE USED AS A BACKFILL MATERIAL. 4. THE BACKFILL MATERIAL SHOULD BE PLACED IN 6" LOOSE LIFTS AND COMPACTED TO 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM-D698). THE FILL SOILS SHOULD BE COMPACTED AT A MOISTURE CONTENT WITHIN +/- TWO PERCENT OF ITS OPTIMUM MOISTURE CONTENT. 5. ANY MATERIAL STOCKPILING ON TOP OF THE UNDERGROUND SCM SYSTEM SHALL BE APPROVED BY THE STRUCTURAL DESIGN ENGINEER. STORMFILTER VAULT CONSTRUCTION NOTES 1. STORMFILTER CONTROL MEASURE CONFIGURATION IS PROVIDED ON SHEET C9.01. 2. ABSOLUTELY NO RUNOFF SHALL ENTER THE STORMFILTER CONTROL MEASURE UNTIL ALL CONTRIBUTING DRAINAGE AREAS HAVE BEEN STABILIZED. 3. MANHOLE ACCESS SHALL BE PROVIDED FOR THE STORMFILTER CONTROL MEASURE. MANHOLES SHALL BE IN COMPLIANCE WITH CITY OF RALEIGH STANDARD DETAILS BUT SHALL BE A MINIMUM OF 24 INCHES IN DIAMETER TO COMPLY WITH OSHA CONFINED SPACE REQUIREMENTS (OR MINIMUM OSHA REQUIREMENTS APPLICABLE AT TIME OF CONSTRUCTION). CONTRACTOR SHALL PROVIDE ACCESS LADDERS FOR ACCESS BELOW ALL MANHOLES. MANHOLE COVERS SHALL ALLOW FOR PROPER VENTILATION. STATEMENT OF RESPONSIBILITY 1. ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THIS FACILITY SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. O O (" 5 O CV O CV CV 00 I I I I I I II I I I PROPOSED PARKING DECK 4- / I i INTERNAL ROOF DRAINAGE LINE; COORDINATE WITH PLUMBING PLANS \ PRIVATE DRAINAGE L --------------X- ----- ------------------- I I �I I I I f I I I I II I -4 I I I III I I Ixl� I I III I I x ❑ II � I I I ICI I I ICI I ❑I I I I I II I � X �JB-102 Z III I I xll I I \ i I f III I I 11 LF 15" R�P i III ® 1.49% xll I I I I I i STORMFILTER VAULT < I I I UNDER PARKING DECK SLAB II I I (SEE DETAIL AND I I ?I I A COORDINATE WITH I I I I STRUCTURAL DRAWINGS) II I I I If I I JII I I _J SEE SHEET C9.01 FOR I / SECTION VIEWS AND DETAILS II STORMFILTER SYSTEM PLAN VIEW 1"=10' SCM CERTIFICATIONS AND AS -BUILT PLANS MUST BE PROVIDED TO STORMWATER CONTROL INSPECTOR, FOR REVIEW, 7 DAYS PRIOR TO FINAL INSPECTION. CERTIFICATIONS AND AS -BUILT PLANS MUST BE ACCEPT PRIOR TO FINAL INSPECTION. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, INC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, INC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, INC 27603 •``� N CARC' '•� SEA._ 034 J55 Ilk 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 STORMWATER CONTROL MEASURE PLAN VIEW AND NOTES C9600 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER STORMFILTER DESIGN NOTES STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (7). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 7 CARTRIDGES. 072" MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.5 CFS. IF THE SITE CONDITIONS EXCEED 1.5 CFS AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 181. LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 1 2.3' 1.8' SPECIFIC FLOW RATE (gpm/sf) 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 1 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 1 2 gpm/sf 1.67* WEST] gpm/sf CARTRIDGE FLOW RATE (gpm) 22.5 1 18.79 1 11.25 1 15 1 12.53 1 7.5 1 10 1 8.35 1 5 * 1.67 gpm/sf SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB `' (PSORB) MEDIA ONLY FRAME AND COVER (DIAMETER VARIES) N.T.S. SITE SPECIFIC DATA REQUIREMENTS STRUCTUREID WATER QUALITY FLOW RATE (cfs) PEAK FLOW RATE (cfs) RETURN PERIOD OF PEAK FLOW (yrs) CARTRIDGE HEIGHT (27", 18", LOW DROP(LD)) NUMBER OF CARTRIDGES REQUIRED CARTRIDGE FLOW RATE MEDIA TYPE (PERLITE, ZPG,PSORB) PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE #1 INLET PIPE #2 OUTLET PIPE RIM ELEVATION ANTI -FLOTATION BALLAST WIDTH HEIGHT NOTES/SPECIAL REQUIREMENTS: * PER ENGINEER OF RECORD GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. 5. STRUCTURE SHALL MEET AASHTO HS-20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 5' AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. 6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. 7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft). 8. STORMFILTER STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND AASHTO LOAD FACTOR DESIGN METHOD. INSTALLATION NOTES A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB AND SAND COLLAR. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR, F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. O O (" 5 L0 O CV O CV CV 00 COUNT DESCRIPTION INSTALLED BY 1 27", 7.5GPM, PHOSPHOSORB CARTRIDGE ( PRP) CONTRACTOR 0 2" PVC SLIP PLUG CONTRACTOR 1 FLOW KIT CONTRACTOR 1 INLET DISSIPATOR CONTRACTOR 1 6" PLUG VALVE CONTRACTOR 1 JOINT SEALANT (BY PRECASTER) CONTRACTOR 2 1030 " x 4" FRAME AND COVER CONTRACTOR PERFORMANCE SPECIFICATION RIM ELEVATION TO BE - SET AT FINAL GRADE OF PARKING DECK SLAB 100-YEAR STORM EL. = 315.68 ° 10-YEAR STORM EL. = 315.67 d 0 CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 12" O.C. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 37SECONDS. SPECIFIC FLOW RATE SHALL BE 1 GPM/SF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPM/CF OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH TO PROVIDE ALL COMPONENTS SPECIFIED IN TABLE ABOVE. 2. CONTRACTOR TO PROVIDE STRUCTURAL DESIGN FOR ALL CONCRETE COMPONENTS UNLESS OTHER ARRANGEMENTS ARE MADE WITH CONTECH PRIOR TO ORDER. 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 4. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, AND CASTINGS SHALL MEET AASHTO M306. INSTALLATION NOTES 1. CONTRACTOR TO PROVIDE AND CAST -IN -PLACE ALL CONCRETE COMPONENTS. 2. CONTRACTOR TO PROVIDE AND INSTALL VAULT STEPS. 3. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. 4. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. 5. CONTRACTOR TO REMOVE TRANSFER HOLE COVER WHEN SYSTEM IS BROUGHT ONLINE. 8" INTERNAL ROO DRAINAGE TI STORMFILTER VAUL INV EL. = 312.5E SEE PLUMBING PLAN FOR UPSTREAP CONTI N UATIO CDARAC Anin PLAN VIEW - EXTERNAL N.T.S. 10'-0" WALL THICKNESS TO BE DETERMINED BY OTHERS d d ° d 0 FLOW _� _ d ° A d d ° C � 4 d s 8"INTERNAL d d d d° ROOF DRAINAGE TO STORMFILTER 7 VAULT 4 d INV EL. = 312.56 SEDIMENT J 6" PLUG VALVE. THE VALVE SHALL BE A M&H STORAGE STYLE 1820 ECCENTRIC VALVE OR APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE VIA A HANDWHEEL. SECTION A -A N.T.S. 4' x 4' SEDIMENT STORAGE WEIR ELEV. = 313.76 CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT O 12" O.C. d d ° d ° d RIM ELEVATION TO BE SET AT FINAL GRADE OF PARKING DECK SLAB INSIDE TOP EL. = 316.56 TOP OF WEIR WALL EL. = 315.56 (1) 27" STORMFILTER CARTRIDGE (PHOSPHOSORB) RCP OUT INV EL. = 310.56 If0917 00"N ►Pi1l�He�i�i7�. CONTECH FLOW KIT ° FLOW d ❑ OUTLET BAY 8" INTERNAL ROOF DRAINAGE TO d STORMFILTER VAULT d d ° ° INV EL. = 312.56 I I SEE PLUMBING PLANS I l FOR UPSTREAM I I CONTINUATION I o d 6=d WEIR WALL 1D THICKNESS (1) 27" STORMFILTER- TO BE CARTRIDGE ° ° DETERMINED (PHOSPHOSORB) BY OTHERS 10'-0" d FILTER BAY d oe WALL THICKNESS TO BE ° DETERMINED BY OTHERS A i d STORMFILTER VAULT DETAILS N.T.S. CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 12" O.C. PLAN VIEW - INTERNAL N.T.S. RCP INV. OUT = 310.56 - 4' x 4' OUTLET BAY WEIR ELEV. = 316.76 SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 �•� �N OARC` 0 ,3i 355 = tiC NEFe' N O 2 0*4 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 STORMWATER CONTROL MEASURE DETAILS C9001 Construction Documents I ! I ! I 1 I SD so- yl� -- J�------ __-- =no===�o� ---- - - - - - - - - - - _no� �_ mow �o 2 - , ,�io - no no - --Kno n0 - EXIS - D.02 CONCRETE PAVERS ON E. LENTING - L4.01 CONCRETE BASE OIR ST MAIN STREET, PARALLEL ARKING - VARIABLE WIDTH D.04 TREE GRATE (CITY OF STUCTURAL SOIL(D.06SIDEWALK SYSTEM L4.01 EASEMENT BUILDING OVERHANG PRIMARY STR L4.01 RALEIGH STANDARD), TYP. - CONCRETE PAVING, PLANTER 2 D.02 D.02 PLANTER 2 ` TYP. 42.1 ' L4.02 L4.02 D.06 STUCTURAL SOIL / 41.1' L4.01 SYSTEM � \ 43.9' D.03 - - - - -\` Z WOODEN BENCH I _ - -- -- -. / I L4.01 -- ---- - - - -- - - '- -- - -- I� - --- ----- - -- ------ 6.9' N F II I = _ --- --- WOODEN BENCH D.03 I ____ - /,--- ---❑ I L4.01 BIKE I 1 L ! EXISTING 020' RACKS L---- RIGHT-OF-WAY BUS STOP SHELTERUILON I ,BD_ APPROXIMATE LOCATIO- L4.01 SHOWN (6'X10') - I 1 ��! SEE ENTRY ENLARGEMENT t 1 1 1� I li I I I EJ 1 1 ! I STAINED CONCRETE PAVING I .I I; I I ! I N I O - - I-i' I I 15'x2O' TRANSIT I 4'dI I -- I I N/F EASEMENT REQUIRED MCDONALDS REAL ALONG WILMINGTON ea -� BUILDING ! ESTATE CO ! I ST (Z-42-14 #6) I I I FIFE 315.50 I 1 P8 :170376 R313 CITY STANDARD N I I I D.B. 14479, PG. 2287 ! ' BRICK PAVERS I 843' N D.08 CONCRETE WALL ! ! ! ! 0 CONCRETE PAVING, SE D.06 �_ D.01 001 STRUCTURAL PLANS FTR ! iBUIILDING OVERHANG ii I L4.01 STUCTURAL SOIL SYSTEM I SEE PAVING J ! SLAB DETAILS I I I� � �} 9 I i IZ i ENLARGEMENT F IErISTING II I I r oI� SEE DECK PLAN R GHT-OF WAY FOR MARKINGS 1 I 1 ® 2.5' SIDEWALK' I I Im I I I I41 ACCESS I ! EASEMENT I I I C I 1 I _ IIII I UTILITY GRATE, SEE ARCHITECTURAL - - - _ _ I I PLANS I I, --------------------I_- - - I I ' -J --------------------------� 1 1 1 114 I ! _! ! I I 11� I MCDONALDS REAL ! _ I! I I Q"' 11 \ I MCDONALDS REAL ESTATE CO J I N/F ESTATE CO I PIN:1703764221 r MCDONN/F REAL ^ ! PIN:1703763211 111 E. SOUTH ST. E- 11 ! 101 E. SOUTH ST. D.B. 14479, PG. 2287 I I STATE CO PIN 80 D.B. 14479, PG. 2287 1 I I 117 E. SOUTH ST. I 11 I Cr3 Qi li I 1 I D.B. 14479, PG. 2287 I z 1 0" I I I �za�� ; L I I 1.4 I I z I I I W I I I I I ENTRY ENLARGEMENT SCALE: 1/4"=V-0" P 7 O O C-s O N O N N 00 ADA RAMP, SEE ARCHITECTS `DRAWINGS I 1 I I 1 I ........... I. 2.0' 6.0' 1 I 0 1 0 1 I o 1 1 1 1.0' 2.0 1.0' 1.7' 3.1' ! N I 1.2' 1.0' 2.0' I 1 1 I I i 3.0' 3.0' 0 0 o HANDRAIL, SEE ARCHITECT'S J D.05 DRAWINGS BOLLARD, TYP. L4.01 PAVING ENLARGEMENT 1"=10'-0" SCALE: D.01 CONCRETE PAVING L4.01 STAINED CONCRETE PAVING Z MATERIALS LEGEND SITE LEGEND T ACC VAN XX TYPE Q TYPE © TYPE SIGNAGE YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL PARKING SPACE COUNT ACCESSIBLE RAMPS PHASE LINE PROPERTY LINE RIGHT-OF-WAY LINE - - - - LOT LINE EASEMENT LINE CENTERLINE SYMBOL TYPE STYLE/MANUFACTURER COLOR/FINISH DETAIL# 3,000 PSI MIN. NATURAL COLOR IN MEDIUM C8.0 CONCRETE PAVING MUST MEET ALL STRUCTURAL AND BROOM FINISH PERPENDICULAR GEOTECHNICAL REQUIREMENTS TO PATH OF TRAVEL STAINED CONCRETE PAVING - COLOR 1 SEE STRUCTURAL DRAWINGS STAIN: SCOFIELD REVIVE PLATINUM GREY D.01/1-4.01 EXTERIOR CONCRETE STAIN STAINED CONCRETE PAVING -COLOR 2 SEE STRUCTURAL DRAWINGS STAIN: SCOFIELD REVIVE CONCRETE GREY D.01/1-4.01 EXTERIOR CONCRETE STAIN STAINED CONCRETE PAVING - COLOR 3 SEE STRUCTURAL DRAWINGS STAIN: SCOFIELD REVIVE BEIGE CREAM D.01/1-4.01 EXTERIOR CONCRETE STAIN BRICK PAVERS CITY OF RALEIGH STANDARD PINE HALL BRICK FULL RANGE C8.0 CONCRETE PAVERS ON CONCRETE BASE MODULINE BY BELGARD 60 MM SEE ENLARGEMENT FOR SIZE AND COLOR D.02/1-4.01 STRUCTURAL SOIL 2'-6' DEPTH N/A D.06/1-4.01 SYSTEM Op TREE GRATE CITY OF RALEIGH STANDARD CAST IRON D.04/1-4.01 FURNISHING SCHEDULE FURNISHING SYMBOL QUANTITY DETAIL #k PRODUCT PRODUCT DESCRIPTION WOODEN BENCH 3 D.03/14.01 PARALLEL 42 BENCH BY WOODEN BENCH - LANDSCAPE FORMS - THERMALLY MODIFIED ASH CUSTOMIZED FOR SITE SLATS (SEE DETAIL) PLANTER 1 ❑ 2 D.02/1-4.02 WILSHIRE COLLECTION 2' X 2' FRP PLANTER BY TOURNESOL COLOR: APPLE TO BE CONFIRMED BY OWNER PLANTER 2 ❑ 3 D.02/1-4.02 WILSHIRE COLLECTION 4' X 4' N BY TOURNESOL COLOR: ROYALTY TO BE CONFIRMED BY OWNER BIKE RACK I I 2 TWIST BIKE RACK CAST ALUMINUM WITH POWDER BY FORMS+SURFACES COAT FINISH - COLOR TO BE CONFIRMED BY OWNER GRAPHIC SCALE 0 10 20 40 BOLLARD 0 7 D.05/L4.01 HELIOS SECURITY 6 IN. DIAM. STAINLESS STEEL BOLLARD BY FORMS WITH SATIN FINISH BOLLARD, AND SURFACES, SEE EMBEDDED SECURITY CORE, 1 inch = 20 ft. SPEC 323300 FOR ILLUMINATED, 360 LIGHT MODEL# DISTRIBUTION GENERAL NOTES: PAVING PATTERN ESTABLISHED ON 6"x12" GRID. CONSTRUCT USING 1. ALL DIMENSIONS ARE TO EDGE OF PAVING UNLESS OTHERWISE 3 SIZES AND 2 COLORS ARRANGED INDICATED. AS SHOWN. 2. ALL CONCRETE SHALL BE 3,000 PSI. PAVER SIZES: 6"x12", 12"x12", 18"x12' COLORS: GRANIT, SUEDE 3. DIGITAL BASE FILE SHALL BE MADE AVAILABLE FOR USE IN FIELD LOCATION OF ELEMENTS AND SITE FEATURES. HARDCOPY INFORMATION SHALL PREVAIL. 4. CONTRACTOR SHALL COORDINATE CONDUIT LOCATIONS (I.E. IRRIGATION, ELECTRICAL, ETC.) WITH SUBSEQUENT DRAWINGS PRIOR TO CONCRETE INSTALLATION. 5. SEE SHEET L2.02 FOR 6TH FLOOR AMENITY LAYOUT PLAN. 6. SEE SHEET L2.03 FOR 6TH FLOOR AMENITY FURNISHINGS PLAN. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: `1 UDA PAIN OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 w nil IITr/�T Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Alllea rlre rroreC lon 80 Rupert Rd. Raleigh, NC 27603 N O 2 C44 N O 2 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA PROJECT NUMBER: QV9,0i HARDSCAPE PLAN - STREET LEVEL L e0l CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER PLf (69 sf) F (38 sf) AJ`. (58 sf) ' STEEL EDGING BETWEE PLANT MATERIALS, TY1 CAFE TABLE WITH TV CHAIRS (3) ASE PLANTER 1, 1 FURNISHING SCHEDULE SYMBOL FURNISHING FIRE TABLE DOUBLE GRILL — � 1 ISLAND QUANTITY DETAIL #! 2 N/A 1 1 /L4.02 PRODUCT PRODUCT DESCRIPTION 55" ASPEN RECTANGULAR 55"X30"X16" FIRE TABLE BY ARCHPOT COLOR: TO BE SELECTED BY ARCHITECT/OWNER BURNER OPTION: FBD MARINE GRADE BURNER (ITEM# FBD—REC-30) AND ALL WEATHER ELECTRONIC IGNITION SYSTEM (ITEM#AWEIS) WITH SEE DETAIL FOR PRODUCT SEE DETAIL FOR PRODUCT INFO INFO PLANTER 2 5 2/L4.02 WILSHIRE COLLECTION BY TOURNESOL SITEWORKS PLANTER 3 10 2/1-4.02 WILSHIRE COLLECTION BY TOURNESOL SITEWORKS PLANTER 3 3 3/L4.02 WILSHIRE COLLECTION BY ® W/ SCREEN TOURNESOL SITEWORKS BEER CART N/A N/A PROVIDED BY OWNER O O M O CV O CV CV 00 2X2 PLANTER COLOR: SHADOW 41 X 1.5'W X 3' HT COLOR: SHADOW 41 X 1.5'W X 3' HT PLANTER PLANTER COLOR: SHADOW SCREEN: POWDERCOATED METAL, COLOR: SHARK CUSTOM PATTERN TO BE PROVIDED UPON REQUEST N/A ADA POOL LIFT J CHEZ LOUNGE (FINAL SELECTIONS FOR THE FOLLOWING FURNISHINGS TO BE MADE BY INTERIOR DESIGNER) SYMBOL FURNISHING QUANTITY PRODUCT L-SHAPED 1 TBD BY INTERIOR SOFA-6 DESIGNER SEATS L-SHAPED SOFA 1 TBD BY INTERIOR - 5 SEATS DESIGNER 3 SEAT SOFA 2 TBD BY INTERIOR DESIGNER ISLAND [BISTRO HEIGHT TABLE] 1 TBD BY INTERIOR DESIGNER TABLE WITH 3 TBD BY INTERIOR FOUR CHAIRS DESIGNER BISTRO TABLE WITH 6 TBD BY INTERIOR TWO CHAIRS DESIGNER CAFE TABLE WITH 10 TBD BY INTERIOR TWO CHAIRS DESIGNER LOUNGE CHAIR 4 TBD BY INTERIOR DESIGNER Ll END TABLE 6 TBD BY INTERIOR DESIGNER CHEZ LOUNGE 5 TBD BY INTERIOR DESIGNER O BISTRO TABLE 9 TBD BY INTERIOR DESIGNER PANT SCHEDULE — AMENITY LEVEL SHRUBS CODE QTY COMMON NAME BOTANICAL NAME 0 ASER 35 Cast Iron Plant Aspidistra elatior 0+ DWHG 14 Wavy Hair Grass Deschampsia flexuoso GROUND COVERS CODE � COMMON NAME BOTANICAL NAME F7PR 69 sf CrazyBlue Russian Sage Perovskia atriplicifolia 'CrazyBlue' HEIGHT CONT 1 gal 1 gal CONT SPREAD 1 gal — — SP 58 sf Little Bluestem Grass Schizachyrium scoparium 'Prairie Blues' 1 gal El AJSC 38 sf Autumn Joy Stonecrop Sedum spectabile 'Herbstfreude' 1 gal PLANTER 3 WITH SCREEN TABLE WITH FOUR CHAIRS (10) DWHG PLANTER 3 BISTRO TABLE WITH CHAIRS NOTE: REFER TO SHEET L2.01 FOR GENERAL NOTES 0 GRAPHIC SCALE 0 5 10 20 1 inch = to ft. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Ducal Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION PROJECT NUMBER: 21901 1 FURNISHING &PLANTING PLAN -FLOOR 6 L e02 Construction Documents •1 O O M LO O tV O CV CV 00 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1 W 1' 1' MATERIALS LEGEND SYMBOL TYPE STYLE/MANUFACTURER STAINED CONCRETE SEE STRUCTURAL DRAWINGS 71= PAVING - COLOR 1 STAIN: SCOFIELD REVIVE co _ ilt = EXTERIOR CONCRETE STAIN N STAINED CONCRETE SEE STRUCTURAL DRAWINGS PAVING - COLOR 2 STAIN: SCOFIELD REVIVE EXTERIOR CONCRETE STAIN pirof STAINED CONCRETE SEE STRUCTURAL DRAWINGS PAVING - COLOR 3 STAIN: SCOFIELD REVIVE _ ur' EXTERIOR CONCRETE STAIN GREEN ROOF N/A PLANTING B ADA + PLANTING AREA, SEE +. . COMPLIANT PERFORATED L2.02/ PLANTING AND ,+++1+1+; r_-----T ---- o-- STAINLESS STEEL 5.25"X24" FURNISHING PLAN --- GRATE BY TRENCH DRAIN + . . + + i ib SYSTEMS COLOR/FINISH PLATINUM GREY CONCRETE GREY BEIGE CREAM SEE L2.02 FOR PLANTING PLAN STAINLESS STEEL n=A ll u DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 ARCHITECT Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 D.01/1-4.01 FIRE PROTECTION Allied Fire Protection D.01/L-4.01 80 Rupert Rd. Raleigh, NC 27603 D.01/1-4.01 SEE ARCHITECTURE PLANS FOR ROOF DETAIL SEE STRUCTURAL PLANS NOTES: 1. REFER TO SHEET L2.01 FOR GENERAL NOTES 2. PLAN INDICATED FLOORING FINISH ONLY. REFER TO ARCHITECTURE AND STRUCTURAL PLANS FOR ASSEMBLIES O 4— O V � N � O N �z GRAPHIC SCALE rn o s io 20 C4 \.J/ •n—, 1 inch = 10 ft. �✓ v 400) `O _0 O SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA I MARK I DATE I DESCRIPTION I PROJECT NUMBER: 21901 HARDSCAPE PLAN - FLOOR 6 L e03 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER psi O O 66 Ln O CV O CV CV 00 BACKER ROD (STRAIGHT JOINTS ONLY) SEAL PREFORMED FIBER EXPANSION JOINT WITH COLORED JOINT SEALANT/CAULK. COLOR SHALL MATCH ADJACENT CONC. AND BE APPROVED BY OWNER'S REPRESENTATIVE " RADIUS ADJACENT PAVED OR VERTICAL SURFACE wq11111IN COMPACTED SUBGRADE- MEETING PROJECT SPECIFICATIONS 4" COMPACTED AGGREGATE BASE NOTES: u v < d d \ \° a e o ° d 1. REFER TO LAYOUT PLAN FOR SIDEWALK LOCATIONS, TYPES AND WIDTHS. 2. REFER TO DETAILED LAYOUT PLAN FOR SPECIFIC JOINT LOCATIONS AND SPACING. 3. USE THIS DETAIL FOR TYPICAL JOINT SPACING WHEN NO SPECIFIC JOINT SPACING IS INDICATED ON PLANS. 4. MAXIMUM SIDEWALK CROSS -SLOPE IS 2%. 5. EXPANSION JOINTS SHALL BE INSTALLED WHERE CONCRETE PAVEMENT ABUTS ALL VERTICAL SURFACES INCLUDING BUT NOT LIMITED TO ALL BUILDINGS, STRUCTURES, STAIRS, CURBS, COLUMNS, WALLS, LIGHT POLES, ETC. 6. WHERE WALK ABUTS RIGID STRUCTURE, JOINT SHALL BE WATERTIGHT. 7. PROVIDE EXPANSION JOINTS @ 20' O.C. MAX UNLESS OTHERWISE SHOWN/ REQUIRED. (SEE MATERIALS & STAKING PLAN) 8. TOOL JOINTS TO A MIN. DEPTH OF 1". CONTRACTOR TO CLOSELY COORDINATE LOCATIONS AND DESIGNS PRIOR TO AND DURING CONSTRUCTION. 9. ALL CONCRETE SHALL BE 3,000 PSI UNLESS OTHERWISE REQUIRED BY PROJECT SPECIFICATIONS. n 7 CONCRETE SIDEWALK - PLAN & SECTION V Ilili& SCALE: 1"=1'-0" Parallel 42 Bench, straight backless unit, 67in length, surface mount Product Drawing Drawing: MU103-02 Dimensions are in inches [mm] U.S, Patent No. D712,168 [1699] 67" [443] 17 1 /2" Date: 2/10/2020 www.landscapeforms.com Ph:800.521.2546 NOTES: 1. MANUFACTURER'S DETAIL PROVIDED FOR REFERENCE ONLY. SEE PLAN FOR CUSTOM DIMENSIONS. 2. CONTRACTOR TO PROVIDE SHOP DRAWINGS FROM LANDSCAPE FORMS FOR APPROVAL BY DESIGNER PRIOR TO FABRICATION. WOOD SEAT AND SIDES [4561 18" \� (4) STAINLESS STEEL GLIDES METAL END SUPPORTS WITH 3/8-16 DROP -IN ANCHORS FOR SURFACE MOUNTING. ANCHORING HARDWARE INCLUDED. CONFIDENTIAL DRAWING INFORMATION CONTAINED HEREIN IS THE PROPERTY OF LANDSCAPE FORMS, INC. INTENDED USE IS LIMITED TO DESIGN PROFESSIONALS SPECIFYING LANDSCAPE FORMS, INC. PRODUCTS AND THEIR DIRECT CLIENTS. DRAWING IS NOT TO BE COPIED OR DISCLOSED TO OTHERS WITHOUT THE CONSENT OF LANDSCAPE FORMS, INC. © 2015 LANDSCAPE FORMS, INC. ALL RIGHTS RESERVED. n'2 CUSTOM PARALLEL 42 BENCH BY LANDSCAPE FORMS VW&P SCALE: N.T.S. = J Q a- LJ u U C F- N N NOTES: 1. TREE GRATE TO BE INSTALLED PER MANUFACTURER INSTALLATION PROCEDURES FOR A POURED CONCRETE APPLICATION. SEE SPECIFICATIONS FOR TYPE. 2. REFER TO SOIL PREPARATION SPECIFICATION FOR STRUCTURAL SOIL MIX. RAME G TOOLED JOINT (TYP) A MIN. 1" DEEP AS SHOWN ON PLAN 4" COMPACTED AGGREGATE BASE COMPACTED SUBGRADE MEETING PROJECT SPECIFICATIONS GRAY IRON, RECTANGULAR 4X6',1.5" MIN. THICK, WITH 1/4" OPENING OR LESS NOTES: \\�V��1 1. GRATE DESIGN MUST BE ADA COMPLIANT. \ 2. GENERAL PATTERN DESIGN MUST BE AS SHOWN. 3. EXCEPTIONS OR PERSONALIZATION MUST BE REVIEWED AND APPROVED BY THE CITY OF RALEIGH. 4. A TREE IMPACT PERMIT IS REQUIRED. 5. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 6. ELECTRIC OUTLETS AND OTHER UTILITIES ARE i PROHIBITED IN THE GRATE AREA. II)�M\\\\ CONTACT INFORMATION: CITY OF RALEIGH PARKS, OSOURCES E PARTM NT URBAN NC GOON AND CULTURAL WWW.RALEIGHNC.GOV a N 73 3/8" FRAME (9o 72114"FRAME 0 w N 36" ! = FRAMES U NGA6X1S4EXB4ED THICK STEEL PLATE BOLTED ALL SLOTS ARE TO FRAME w/ (213/8-16UNC 1 112• IX 1 STNLS STL. FFLAT HD. Y," WIDE MAX. 3/4• CAP SCREWS BOLT TREE GRATE HALVES TOGETHER w/ I (2) 1/2"-13 x 3" STNL. STL. HEX BOLTS, GALV. FLAT WASHERS AND STNL. STL. HEX NUT BOLTED PLATE (2) 318-16UNC 4 3/41. r6 ] 31 �q• TAPPED HOLES y�IjuF,3!` i ASSEMBLY DETAIL -I 1� CITY OF RALEIGH NOTE: ALL DIMENSIONS SHOWN ARE IN ENGLISH STANDARD DETAIL MATERIAL: CAST GRAY IRON ASTM A-48, CLASS 35B REVISIONS FAM alma NOTMSW.E FINISH: NO PAINT WEIGHT: 608#/SET nA CITY OF RALEIGH TREE GRATE V SCALE: NTS 10'-10" s �• w b 3X3 ALUMINUM POST LEAN BAR J Z BENCH COLUMN BASE� D D D 6" NOTES: 1. SHELTER SHOWN IS A FULL SIZE BRASCO MODEL TL 510 ILS, OR APPROVED EQUAL. COORDINATE WITH CITY OF RALEIGH FOR SHELTER TYPE. 2. INSTALL COLUMN BASE 6" FROM EDGE OF CONCRETE PAD WITH APPROVED CONCRETE ANCHOR UNITS RECOMMENDED BY THE MANUFACTURER, TYPICAL UNLESS OTHERWISE SHOWN. 3. INSTALL BENCH ON OPPOSITE SIDE OF LEAN BAR. 4. ALL CERTIFICATIONS OF STRUCTURES TO BE PROVIDED BY MANUFACTURER. CITY OF RALEIGH STANDARD DETAIL REVISIONS aarE..a1n8 NOTTOiFE BUS SHELTER LAYOUT TT-03 CONCRETE SIDEWALK SLOPED AWAY FROM WALL, SEE ARCHITECTS DWGS FOR DETAIL EXPANSION JOINT WITH BACKER ROD (DTL1 /L-4.01) COMPACTED AGGREGATE BASE r PAVER JOINT: POLYN 1" POLYMERIC JOINTING SAND SI M d CONCRETE COMPACTED SUBGRADE ME GEOTECHNICAL/STRUCTURAL F 2" PVC WEEP SPACED 8' ., FILL WITH WASHED PEA GRAVEL PEDESTRIAN PAVER NOTES: 1. CONTRACTOR TO CONSTRUCT A 4' X 4' MOCK-UP OF EACH PAVER TYPE FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO FULL INSTALLATION. MOCK UP MAY BE INCLUDED AS PART OF FINAL INSTALLATION IF APPROVED. 2. INSTALL PAVERS PER MANUFACTURER'S SPECIFICATIONS. CUT PAVERS AS NECESSARY BUT NOT MORE THAN 1/3 OF THE TOTAL WIDTH OF THE PAVER TO AVOID SLIVERS. 3. REFER TO HARDSCAPE MATERIALS PLAN FOR PAVER PATTERNS, LOCATIONS OF PAVER TYPES AND PAVER BAND LOCATIONS. 4. CONTRACTOR TO VERIFY DEPTHS OF AGGREGATE BASE WITH GEOTECHNICAL ENGINEER. n 7 PAVERS ON CONCRETE BASE V `I SCALE: 1"=1'-0" BOLLARD CONCRETE FOOTING, MIN. 3,000 PSI CONCRETE PAVING, SEE ARCHITECT'S DRAWINGS a a a d d aQ 4 4 Q 4 JIIi�III3II 11 I 1 OBOLLARD %5 SCALE: NTS 13 4" CHAMFER 1" REVEAL POURED -IN -PLACE CONCRETE WALL WITH LIGHT SAND BLASTED FINISH #4 DOWELS CONTINUOUS AT 12" O.C. #4 DOWEL AT 12" O.C. SEE CIVIL DWGS FOR VAULT DETAIL COMPACTED SUBGRADE MEETING GEOTECHNICAL/ STRUCTURAL REQ'S NOTES: 1. LEAN WALL MAY RETAIN UP TO 12" HEIGHT BEHIND WALL. WHERE WALL DOES RETAIN, CONTRACTOR TO PROVIDE SWALE BEHIND WALL FOR POSITIVE DRAINAGE AWAY FROM WALL. 2. TOP -OF -WALL SLOPE 1/4" PER FOOT IN DIRECTION OF HARDSCAPE FOR DRAINAGE. PLAN SITE PERMIT REVIEW APPROVAL ',ITY OF RALEIGH - PLANS AUTHORI7ED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St l Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 N N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION HARDSCAPE DETAILS L e0l Construction Documents 06TREE GRATE AND STRUCTURAL SOILS SCALE: 3/4" = 1' 07 CITY OF RALEIGH BUS STOP SHELTER SCALE: NITS n Q CAST IN PLACE CONCRETE WALL V V SCALE: 3/4"=1'-O" CITY 01 RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER O O C` i LO O N O N N 00 JOINTS IN COUNTER MATERIAL SHALL BE LOCATED BEHIND AND ON CENTER WITH THE GRILLS GLASS RAILING, EDGE OF GRILL COUNTER SHALL BE SPACED 2" MIN. FROM RAILING SINGLE ACCESS DOORS — SHALL BE INSTALLED ON CENTER WITH GRILLS GLASS RAILING, EDGE KNOB STUB HANDLE OF GRILL COUNTER ATTACHED TO GRILL WITH SHALL BE SPACED 2" CONNECTING BOLTS MIN. FROM RAILING (THIS SIDE ONLY) WALL RECESS FOR ACCESSIBLE WORK AREA 1 2'-10" 2'— 6 1 II II II IL N I I 1 1 '-1 5/8" OUTDOOR KITCHEN: PLAN VIEW KNOB STUB HANDLE ATTACHED TO GRILL WITH CONNECTING BOLTS 110V GFCI RATED (THIS SIDE ONLY) OUTDOOR ELECTRICAL SOCKET (ONE EACH SIDE) 1 WALL RECESS FOR ACCESSIBLE WORK 10" AREA 3 O O 0 �J O TIMER EMERGENCY SHUT—OFF SWITCH SHUT OFF BALL VALVE STONE VENEER, TILE SELECTION TO BE COORDINATED WITH INTERIOR DESIGNER NOTES: 1. REFER TO ARCHITECTURAL AND ENGINEERING DWGS FOR GAS LINE DETAILS AND CONNECTION INFORMATION. 2. 2PSI TO z PSI PRESSURE REGULATOR FOR NATURAL GAS 3. ROUTE GAS LINE THROUGH STONE ENCLOSURE TO CONNECTION POINT ON GRILL. 4. CONTRACTOR SHALL LAYOUT BALL VALVE, TIME/EMERGENCY SHUT—OFF, AND GAS LINE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS AND REQUIREMENTS. ELEMENTS SHOWN HERE ARE FOR ILLUSTRATIVE PURPOSES ONLY. OUTDOOR KITCHEN: FRONT ELEVATION n 7 DOUBLE GRILL ISLAND V Z SCALE: 1/2" = 1'-0" blur. NOTES: UNLESS OTHERWISE SPECIFIED 1) MATERIAL: GLASS FIBER REINFORCED CONCRETE (GFRC) NOMINAL WALL THICKNESS 1/2" - 3/4" 2) ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY, 02 TOURNESOL PLANTER SCALE: N.T.S. OUTDOOR KITCHEN: BACK ELEVATION PEDESTAL LAYOUT v a� PROVIDED BY MANUFACTURER COLOR:_ TEXTURE: A GLASS RAILING, SEE ARCHITECTURAL DWGS — STONE VENEER, TILE SELECTION TO BE COORDINATED WITH INTERIOR DESIGNER CONTRACTOR TO COORDINATE REQUIRED VENTING PER GRILL MANUFACTURER SPECIFICATIONS APPROVAL: Signature authorizes to manufacture the (21") 24" DRAINAGE HOLE:. TO BE PROVIDED BY MANUFACTURER To 2930 Faber Street, Union City, CA 94587 DRAWN: MLC 10/28/2016 SIZE DWG NO C WCR-2400-SUB ALL DIMENSIONS IN INCHES SCALE 1 / 6 DETAIL B, as shown WILSHIRE WCR-2400 MATERIAL: GFRC 0 STONE VENEER TO EXTEND BELOW FINISH GRADE 3" MIN. ON ALL SIDES ADJACENT HARDSCAPE. REFER TO HARDSCAPE PLANS & ARCHITECTURAL DWGS FOR CONCRETE FLOOR SLAB 2'-6" OUTDOOR KITCHEN: SIDE ELEVATION OUTDOOR KITCHEN: STONE VENEER COLOR TO BE COORDINATED WITH INTERIOR DESIGNER AND ARCHITECTURAL FINISHES OUTDOOR KITCHEN PRODUCTS (OR COMPARABLE PRODUCTS) INSTALLED PER MANUFACTURER SPECIFICATIONS: 1. BUILT—IN GRILL MANUFACTURER: AMERICAN OUTDOOR GAS GRILL — "T" SERIES 30" MODEL MODEL: 3ONBT—OOSP, 30" BUILT—IN FINISH: STAINLESS STEEL CONTACT: BBQGUYS.COM CUT OUT DIMENSIONS: PER MANUFACTURER 2. SINGLE ACCESS DOOR UNDER GRILLS MANUFACTURER: AMERICAN OUTDOOR GRILL MODEL: 24-17—SSDR (17 IN. RIGHT HINGED SINGLE ACCESS DOOR & 17 IN. LEFT HINGED SINGLE ACCESS DOOR) FINISH: 304 STAINLESS STEEL CONTACT: BBQGUYS.COM DIMENSIONS: 22" X 28.5" CUT OUT DIMENSIONS: PER MANUFACTURER 3. COUNTERTOP SURFACE MANUFACTURER: DEKTON MATERIAL: BROMO FROM NATURAL COLLECTION EDGE 4" BULLNOSE BASIS OF DESIGN: DEKTON.COM 4. NATURAL STONE TILE MANUFACTURER: DALTILE MODEL: AMBASSADOR —RANDOM LINEAR MOSAIC —JET SETTER DUSK (VERTICALS COLLECTION) THICKNESS: BASIS OF DESIGN: DALTILE.COM 5. TIMER/EMERGENCY SHUT—OFF SWITCH PRODUCT SHALL BE SKYTECH "E—STOP2-5" OR EQUAL PRODUCT WITH 1 HOUR TWIST TIMER AND RED PUSH KNOB SHUT—OFF. NOTES: 1. DETAIL CONVEYS DESIGN INTENT. CONTRACTOR TO PROVIDE SHOP DRAWINGS, INCLUDING ALL HARDWARE, CONNECTORS, MATERIALS, ETC. FOR APPROVAL PRIOR TO CONSTRUCTION. 2. ALL ELECTRICAL EQUIPMENT INCLUDING INSTALLATION OF GRILL SHALL BE INSTALLED BY QUALIFIED ELECTRICIAN WITH PROPER GROUNDING AND GROUND FAULT INTERRUPTION CIRCUIT BREAKERS. 3. CONTRACTOR TO ENSURE ALL GRILLS ARE VENTED PER MANUFACTURER'S SPECIFICATIONS. 4. REFER TO ENGINEERING DRAWINGS GAS CONNECTION. 5. CONTRACTOR TO PROVIDE OWNER WITH SAMPLE MATERIALS (COUNTERTOP, STONE VENEER, ETC.) FOR FINAL APPROVAL BY OWNER. 6. REFER TO STRUCTURAL DRAWINGS FOR ALL FOUNDATION SIZING, REINFORCEMENT AND CMU BLOCK REINFORCING. 7. CONTRACTOR TO CUT NO MORE THAN J OF STONE VENEER TO AVOID SLIVERS. ANY DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT FOR RESOLUTION PRIOR TO INSTALLATION. JE VENEER ANCHORED TO STEM WALL MANUFACTURER'S SPECIFICATIONS X16" CMU. GROUT MASONRY SOLID (TYP) ADJACENT FITNESS AREA — SEE PLANS FOR MATERIAL REFER TO STRUCTURAL DRAWINGS FOR REINFORCEMENTS GAS CONNECTION BY OTHERS. REFER TO GRILL MANUFACTURER SPECIFICATIONS. APPROVAL: 48" (44") 2" (14") 18" 2" DETAIL B PLAN A I I 18" I A ELEVATION e SECTION manufacture the product as shown NOTES: UNLESS OTHERWISE SPECIFIED 1) MATERIAL: GLASS FIBER REINFORCED CONCRETE (GFRC) NOMINAL WALL THICKNESS 1/2" - 3/4" 2) ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY. COLOR: TEXTURE: To 930 Fa l r Street, TITLE so 2930 Faber Street, Union City, CA 94587 WCR-481818 LAWN: WAY 12/10/2015 tE DWG NO REV C WCR-481818-SUB A L DIMENSIONS IN INCHES SCALE 1/10 MATERIAL: GFRC SHEET 1 OF 1 NOTE: PATTERN INDICATES DESIGN INTENT AND DESIGNER WILL PROVIDE DIGITAL FILE FOR FABRICATION. 4' �4" SIDE ELEVATION (WX3-721824-78X) (OFFSET) °°°°°°°°°0000000°°°°°°°°°°°°°00000000000......................................... . oo 0 0 0 0 00 0 0 0 0 0 00 0 0 0 0 °°°°°°°°°°°°°°°°°°e ........................„ .........„.„0..,..,..... °°°°°°°°°°°°°°°°° O O O O O O O O O O O O O O O O O O O o0000000000000000000000 O O O O O O O O O O O O O O O O O O O o000000000 ........... o o 0 0 0 o o 0 0 0 o o 0 0 0 o o 0 0 0 o o 0 O O O O O O O O O O O O O O O O O O O ....................... 000000000000000000000000 000000000000000--0 00000000000 O O O O O O 000000000000000000000000 0000000"0000000000"00000000000 0000000000 00000000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000000co00o00o00o00000000000000 O O O O O O 0000000000 o 0 o o 0 0 0 0 0 0 0 0 0 0 0°°° °°°°°°°°°°............::::::::::::::::::::::: O O O O O O 000 0 o 0 o 0 o 0 0 o 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O o o — o — o — o — o o — o o — 0 O O O O O O 000cococo00ococo000000 o000 0 0 0 0 0 0 0 ...................................... W66' O O O O 0000 O O O O o0 00000000000000000000000000000000000000000000000 °°°°°°°°°°000000000000000o00o00o00o00000000000 O O O O O O O O O O O O 0000000000000000000000000000000000000000000 000 O 00 O 00 00 O 00 O °Ooo°°°°°00000000000000°°°°°°°°0000 o o o o o o o o o o o o o o o o o 0000000000 O O O O O O O O 000000000000o00o00o0000000000000000 o o o 0 o 0 o 0 o o 0 o 0 o 0 o 0 0000000000 O O O O O O O O 000000000000o00o00o0000000000000000 o o o o o o o o o o o o o o o o o 0000000000 0000000000000000000000000000000000 00000000000000000000000 O O O O O O O O 000000000000000000000000000000000000000000000000000000000 oo—o—o—o—oo—oo 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o—o—oo—o—oo—oo 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o o 0 0 0 o 0 0 0 o 0 0 0 o 0 0 0 o o 0 0 0 o 0 0000000000000000000000000 O O O O O O O O O o O O O O O O O O °°°°°°°°°°°°°°°°°°o e o o 0 o 0 o o o o o o o o 0 000 0 0 `00000 000000000000000000°°°°°°°°°°°°°000° 0000—coo—co—oo0 00000°° °°°°°00000—o—o°°°°°°°°°°°°°°°°°°°000 o °°°°°°°°° 00 O O O O O O O oo o o o o o o o o0 °°°°°°°°° o00000000 oo oo oo o oo °°°°°°°°°°°°°°°°°°°°°° 000000000a000000000000000°°°°°°°°°°°° OOOO 00000000000000000000000000— — 00000O O O O O O O O 0000000000000000000000000000000000000000 000000000000000000000000 o o o o o o o o o o, o, 0 0 o a...,..,..,.„.„ ................................. 000000000000000000000000 o o o o o o o o o o o o o o o o 000000000000000000000000 o o o o o o o o o o o o 0 o o o=^^_^__^__^_^^_^^_^__^__^_^^_^__^__^_^^_^^_^__^__^ .................................................. O O O O O O O O O O O O O 00000000000000000000000000000000o000000000 °°°°°°°°°00000000000°°°°°°°°°°°°°0000000 O O O O O O O O O O O O O 000000000000 oo-o-o-oo-oo-oo-oo °°°°°°°°°°°°°°°°°°°°° °°°°°°°°°°°°°°°°°°°°° 0 O O O o 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 ..,.ee.ee.e..e..e.ee.ee.e..e..e.ee.e..e..e. o O O O O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O o 0 0 0 0 o O O O O O O O O O (PLANTER) CUSTOM DESIGN PATTERN DETAIL SCALE: 1 "=10' NOTE: DETAIL SHOWS ATTACHMENT METHOD UNLY. SUKLLN SHALL L L UU51 UM—UU I ML IF PATTERN BY TOURNESOL. CUSTOM DESIGN PATTERN DETAIL IS SHOWN ABOVE. DESIGNER WILL PROVIDE FINAL DIGITAL PATTERN FILE FOR FABRICATION. ANCHOR PER MANUFACTURER'S RECOMMENDATION. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR APPROVAL BY DESIGNER PRIOR TO FABRICATION ELEVATION n 02 TOURNESOL WILSHIRE SCREEN V1111o# SCALE: N.T.S. VrG3-7248 PANEL BPAC FRP PLANTEI PATTERN H PATTERN G PATTERN F o o o o o 0000° PATTERN E 0 0 o PATTERN D 0 0 0 O O O O O O PATTERN C O O O 00000 PATTERN B 00000 0000° PATTERN A 1.5" BORDER, TYP. WILSHIRE SCREEN PLANTERS INSTALLED IN AREAS THAT EXPERIENCE WIND GUSTS OVER 40 MPH MUST BE ANCHORED TO PREVENT TIPPING. SEE TOURNESOL SITEWORKS' PLANTER ANCHORING GUIDELINES FOR RECOMMENDATIONS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA PAINE ARCH I T E C T S OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 n— nW1 W � O I O N 4-U Z E •n-1 ^ W V) J LPL �O �J This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK DATE DESCRIPTION HARDSCAPE DETAILS L e02 Construction Documents GENERAL LANDSCAPE NOTES: 1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2. CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 3. LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 4. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 5. ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 6. THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 7. VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 8. LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF "AMERICAN STANDARD FOR NURSERY STOCK" AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 9. ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAYBE REJECTED BY THE LANDSCAPE ARCHITECT. 10. ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 11. ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 12. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL PLANTING AREAS. 13. PROPOSED TREES TO BE PLANTED A MINIMUM 10 FEET FROM ANY FIRE HYDRANT AS MEASURED FROM TRUNK OF THE TREE TO THE HYDRANT. 14. CONTRACTOR SHALL COMPLETE SOIL TEST IN ALL PLANTING AREAS TO DETERMINE SOIL AMENDMENT REQUIREMENTS UNLESS WAIVED BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ADJUST PH AND FERTILITY BASED UPON THE SOIL TEST RESULTS. 15. TOPSOIL SHALL BE FREE OF MATERIAL LARGER THAN 1.0 INCH IN DIAMETER OR LENGTH AND SHALL NOT CONTAIN SLAG, CINDERS, STONES, LUMPS OF SOIL, STICKS, ROOTS, TRASH, OR OTHER EXTRANEOUS MATERIAL. 16. LOOSEN SUBGRADE / SURFACE SOIL TO A MINIMUM DEPTH OF 6 INCHES. APPLY SOIL AMENDMENTS AND FERTILIZERS AS REQUIRED BY THE SOIL TEST RESULTS TO ACHIEVE A HEALTHY GROWING MEDIA AND MIX THOROUGHLY INTO TOP 4 INCHES OF SOIL. SPREAD PLANTING SOIL MIX TO A DEPTH OF 6 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 17. THE SUBGRADE SHALL BE SCARIFIED OR TILLED TO A DEPTH OF AT LEAST 6 INCHES PRIOR TO INSTALLATION OF IMPORTED TOPSOIL. FOLLOWING INSTALLATION OF IMPORTED TOPSOIL, THE TOPSOIL SHALL BE TILLED TO INTEGRATE THE SOIL PROFILES. 18. PLANT MATERIALS ARE TO BE GUARANTEED FOR A PERIOD OF 12 MONTHS. PLANT MATERIALS WHICH REMAIN UNHEALTHY WILL BE REPLACED BY THE LANDSCAPE CONTRACTOR BEFORE THE EXPIRATION OF THE GUARANTEE PERIOD OR IMMEDIATELY IF SO DIRECTED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 19. DO NOT PRUNE TREES AND SHRUBS BEFORE DELIVERY. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND -TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY THEIR NATURAL SHAPE. PROVIDE PROTECTIVE COVERING OF EXTERIOR PLANTS DURING DELIVERY. DO NOT DROP EXTERIOR PLANTS DURING DELIVERY AND HANDLING. 20. DELIVER EXTERIOR PLANTS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED AND INSTALL IMMEDIATELY. IMMEDIATELY AFTER UNLOADING, STAND THE TREES UP TO REDUCE THE RISK OF SUN SCALD. PROPERLY STAGED TREES ARE STANDING, UNTIED AND SPACED. UNLESS IMMEDIATELY INSTALLED, SET EXTERIOR PLANTS AND TREES IN SHADE, PROTECT FROM WEATHER AND MECHANICAL DAMAGE, AND KEEP ROOTS MOIST. 21. SEE LANDSCAPE DETAILS FOR TREE STAKING REQUIREMENTS. 22. CONTRACTOR SHALL REMOVE DEBRIS AND FINE GRADE ALL PLANTING AREAS PRIOR TO INSTALLATION. 23. REMOVE GUY WIRES AND STAKES AT END OF WARRANTY PERIOD OR ESTABLISHMENT. 24. FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISHED GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE. M. i7 O O 615 O N O N N CO I i 8 I f CB CB I 8 I To ��-318.4 0 II I 15RCP(E =315.6()=." IP(S)=316.74 15RCP(W315.7 C(W)=316.43 SDI- S DI d - 319.07 316.97 II f I _ ' I ITR ® L-T- _ I _w1L - WV I - In WV - _ - - - - - - - -------------�- r�t _ w - nos------ --- ------ w W IN w W w w� � --'� �0 --�T- -T- z - -- r -w w W = - - - no4 0 _ no -�no N w w w wW ---- w W- _w w I BUILDING IL II E LENOIR GRATE=311.(I w w w W_ - f OVERHANG ST 15"RCP(N)=308.98 I - MAIN STREET, PARALLEL pARKI ID P(S)=308.99 VARIABLE WIDTH SIDEWALK _ EASEMENT EXTENT OF CONCRETE 66 PUBLIC R/W) / PAVERS BENCH, PLANTER (PRIMARY STREET) SS CSC BENCH, TYP.' I PLANTER TYP. , BENCH, BIKE °J TYP. RACK (2) (4) ZSV -J_ F PLANTER / IN 1 ' - L I N---- ---0 - _ - ---J ---L-- --------- - IJ I--------L------ - - --i-J - -- --- - I F ----- ' --- -- -- - - - - - - - t - I N I (3) AS () LMSD L 10 I EXISTING I f - I o 90 I RIGHT-OF-WAY I - - PLANTER (3 sf) ANNU BUILD -TO LINE - N I� J � _ �I I I I � I 1 (9) BSGM BUILDING I i i I I I I II v FFE 315.50 I I I 6'x10' BUS STOP APPROXIMATION ' I (27) LMSD ° II 15'x2O' TRANSIT } EASEMENT REQUIRED I I I a I MCDONALDS LONG WILMINGTON I I o I PIN: 1703765313 I T (Z-42-14 #6) I (42) LMSD 118 E. LENOIR ST. I I D.B. 14479, PG. 2287 I I I II -- I I I f I I� (2) ULM I i STRUCTURAL SOIL SYSTEM EF I N EXISTINGN I I I I RIGHT-OF-WAY I UNDERGROUND I I TRANSFORMER 141 I SIDEWALK I I I VAULT ACCESS I I II I I EASEMENT IIrn -- - I f �r - - - - I F- I in I� II III ----------------- -------------------------- - t� I 13*d I f-a----- I 1 ---� I I I )Z I I I �I I L--- I I I I 1 I I 1 I N/F f II\\�I 1� I N/F MCDONALDS REAL 1 1 _ _ _ - - l� MCDONALDS REAL I ESTATE CO __ _ PIN:1703764221 r J N/F -a ^ II / PIN1703763211 111 E. SOUTH ST. I MCDONALDS REAL I ~I I E I I J D.B. 14479, PG. 2287 I ESTATE CO Z W I 101 E. SOUTH ST. I I PIN:1703764280 I 0 as a �I D.B. 14479, PG. 2287 I 117 E. SOUTH ST. Z� U E I I I D.B. 14479, PG. 2287 I W�Wa I I --- I I coo"A i I ------------- I I I •w � I I Z I I v l I I I I I II I cn to I I I I 1 � \ =0"11 M016 a91N1Ia TREES CODE CITY COMMON NAME BOTANICAL NAME CAL HEIGHT • AS 3 Amagi Shigure Japanese Maple Acer palmatum `Amagi Shigure' 2" 10' min • ULM 2 Princeton American Elm Ulmus americana 'Princeton' 3" min 14' min 0 ZSV 4 Sawleaf Zelkova Zelkova serrata 'Village Green' 3" min 14' min SHRUBS CODE QTY COMMON NAME BOTANICAL NAME HEIGHT SPACING BSGM 9 Green Mountain Boxwood Buxus sempervirens x sinica 'Green Mountain' 18-24" GROUND COVERS CODE QTY COMMON NAME BOTANICAL NAME CONT HEIGHT O O O O� �O ANNU 3 sf Annuals Annuals Annuals - 000 LMSD 79 Lily Turf Liriope muscari 'Silver Dragon` 1 gal GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. GRAY IRON, RECTANGULAR 41R, 1.5" MIN. THICK, WITH 1/4" OPENING OR LESS NOTES: 1. GRATE DESIGN MUST BE ADA COMPLIANT. 2. GENERAL PATTERN DESIGN MUST BE AS SHOWN. 3. EXCEPTIONS OR PERSONALIZATION MUST BE REVIEWED AND APPROVED BY THE CITY OF RALEIGH. 4. A TREE IMPACT PERMIT IS REQUIRED. 5. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 6. ELECTRIC OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE GRATE AREA. CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER:TREES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV a �N So o Z 0 I N �m c� L r FRAMES ARE ASSEMBLED USING A 6" X 1 1/4" X 1/4" g THICK STEEL PLATE BOLTED m TO FRAME w/ (2) 3/8-16UNC 1 V2" X 1 STNLS STL. FLAT HD. o 314' CAP SCREWS �� TOGETHER w/ (2)1/2'-13 x 3" STNL. STL. HEX BOLTS, GALV. FLAT WASHERS AND STNL STL. HEX NUT 1 1/4'• 3/4' 43/4'• _ ItT [^ -�Tn• EEO NOTE: ALL DIMENSIONS SHOWN ARE IN ENGUSH MATERIAL: CAST GRAY IRON ASTM A48, CLASS 35B FINISH: NO PAINT WEIGHT: 608#NSET BOLTED PLATE (2)318.16UNC TAPPED HOLES ASSEMBLY DETAIL .......................................................................................................................................................... . DO NOT PRUNE LEADER. PRUNE OR CUT ONLY DEAD OR UNHEALTHY BRANCHES PROVIDE STAKING IF SPECIFIED. IF STAKING IS PROVIDED, PROTECT TREE WITH BROAD STRAP OR FLEXIBLE TUBING. ALLOW FLEXIBILITY IN STRAPS TO DEVELOP TRUNK TAPER. PROVIDE TURN BUCKLE AND WARNING FLAGS. REMOVE ALL STAKING AND ACCESSORIES WITHIN ONE YEAR FROM PLANTING. THE ROOT FLARE SHALL BE PLANTED AT GRADE,' NO HIGHER THAN T ABOVE GRADE, AND NEVER BELOW GRADE. REMOVE EXCESS SOIL TO EXPOSE THE ROOT FLARE AT GRADE. TREE SHALL BE SET PLUMB MULCH DEPTH 3". KEEP MULCH 3" FROM ROOT FLARE AND DO NOT CONTACT STEM HIGH QUALITY SOIL MIX AS SPECIFIED WATER SAUCER, IF SPECIFIED, SHALL RISE NO, MORE THAN 3" ABOVE GRADE., COMPLETELY REMOVE TOP HALF OF BURLAP, LACING STRAPS, NAILS AND WIRE BASKET AND _ DISCARD FROM HOLE. ALL SYNTHETIC BURLAP MUST BE REMOVED FROM SIDES OF ROOT BALL -I ROOT BALL SHALL BE PLACED DIRECTLY ON COMPACTED SUBGRADE. HANDLE TREE BY THE ROOT BALL ONLY. 3X ROOTBALL DIAMETER CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: THEES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE DRAINAGE OF ALL PLANTING PITS. (POSITIVE DRAINAGE AWAY FROM PIT) 2. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 3. STREET TREES MUST BE 3" CALIPER AT INSTALLATION WITH A 5' MINIMUM FIRST BRANCH HEIGHT. CITY OF RALEIGH 4. PLANTING SEASON OCTOBER - APRIL. STANDARD DETALL 5. A TREE IMPACT PERMIT IS REQUIRED. REWS/ONS oareann8 WTTOS aE 6. ELECTRICAL OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE PLANTING AREA TREE PLANTING DETAIL IMMEDIATELY SURROUNDING THE TREE. TPP-03 ---------------------------------------------------------------------------------------------------------------------------------------------------------- NOTE: SEE TREE MULCH 3" DEEP MAX. AND 3" MIN. FROM THE PLANTING DETAIL BASE OF THE TREE Jo SIDEWALK PAVING AND SUBBASE * PLANTING SOIL MIXASSPECIFIED 4" DIA. PVC PIPE WRAPPED IN FILTER a III III -III -1 FABRIC AND CONNECTED TO STORM -III-1 -III- DRAINAGE SYSTEM WHERE APPLICABLE SECTION COMPACTED OR UNDISTURBED SUBGRADE NOTES: 1. A SITE SPECIFIC PLAN MUST BE DEVELOPED TO ENSURE THAT: 1.1. EACH TREE IS PROVIDED A MIN. ROOT -ACCESSIBLE SOIL VOLUME OF 600 CUBIC FEET. 1.2. THE TREE ROOT AREA BENEATH THE SIDEWALK IS EXPANDED TO MAXIMIZE ROOT ACCESSIBLE SOIL SPACE UNDER THE PAVEMENT. 1.3. CONNECT SOIL SPACE FOR ROOT EXPANSION WHERE POSSIBLE TO ALLOW ROOT SYSTEMS OF TREES TO OVERLAP AND COLONIZE A SHARED SOIL SPACE. 1.4. ANY COMBINATION OF STRUCTURAL SOILS, SOIL CONTAINMENT SYSTEM (e.g., SILVA CELL), OR ROOT CHANNELING (e.g., SOIL STRIP DRAIN/AERATION SYSTEM) THAT PERFORMS AS SPECIFIED IS ACCEPTABLE. 3. 40' X 6' WIDTH MINIMUM APPLIES TO BOTH STRUCTURAL SOILS AND SUBSURFACE SOIL CONTAINMENT SYSTEMS. 4. SUBSURFACE APPLICATION SHALL BE REVIEWED AND APPROVED BY CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES URBAN FORESTRY DIVISION PRIOR TO INSTALLATION. STRUCTURAL SOIL SYSTEM SOIL CONTAINMENT SYSTEM ROOT CHANNELING/PATHWAYS CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV SITE LEGEND ACC VAN 7 TYPE AQ TYPE © TYPE SIGNAGE YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL PARKING SPACE COUNT ACCESSIBLE RAMPS ■II �II�II�II�II■ PHASE LINE - - PROPERTY LINE - - - RIGHT-OF-WAY LINE - - - - LOT LINE EASEMENT LINE CENTERLINE LANDSCAPE CALCULATIONS STREET TREES E LENOIR ST: 211 LF TREES REQUIRED: 5 (1/40 LF) PROVIDED: 4 *(UNABLE TO MET MINIMUM SPACING DUE TO UNDERGROUND UTILITY CONFLICTS) S WILMINGTON ST: 105 LF TREES REQUIRED/PROVIDED: 2 (1/40 LF) URBAN PLAZA (2,450 SF OUTDOOR AMENITY AREA REQUIRED) SEATING REQUIRED: 49 LF (1/50 LF) SEATING PROVIDED: 49 LF 2" CALIPER TREES REQUIRED: 3 TREES (1/1,000 LF) 2" CALIPER TREES PROVIDED: 3 TREES NOTES: 1. SEATING AREAS SHALL INCLUDE BUT NOT LIMITED TO BENCHES, CHAIRS, OUTDOOR DINING TABLES, MOVABLE/FIXED CHAIRS AND/OR SEAT WALLS. SEATING MY BE PROVIDED ANYWHERE WITHIN THE OUTDOOR AMENITY AREAS OR ALONG THE STREETSCAPE. FINAL LOCATION TO BE SHOWN WITH BUILDING PERMIT OR ENHANCED LANDSCAPE/HARDSCAPE DRAWINGS BY OTHERS. 2. ALL TREES LOCATED WITHIN IN A SIGHT DISTANCE TRIANGLE SHALL BE LIMBED UP TO A MINIMUM 8' ABOVE FINISHED GRADE AT MATURITY. 3. " STREET TREES SHALL BE PLANTED IN ACCORDANCE WITH CITY OF RALEIGH TREE PLANTING DETAIL TPP-006, TPP-07 BETWEEN OCT 1 AND APRIL 30. A LANDSCAPE AGREEMENT IS NEEDED IF CERTIFICATE OF OCCUPANY IS REQUIRED OUTSIDE OF THE PLANTING WINDOW. CONTACT THE URBAN FORESTRY INSPECTOR WITH QUESTIONS. 4. STREET TREES MUST BE MAINTAINED FOR A PERIOD OF ONE YEAR FOLLOWING THE CITY'S APPROVAL OF THE STREET TREE PLANTING. 5. PLANTING BEDS AND POTS TO BE IRRIGATED. CONTRACTOR TO PROVIDE COMPLETE IRRIGATION SYSTEM INCLUDING EMMITTERS, LINESM AND OPERATION MANUAL. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO INSTALLATION. 6. STREET TREES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 2 OF THE CITY TREE MANUAL. 7. ALL STREET TREES ARE TO BE PLATED IN ACCORDANCE WITH CITY OF RALEIGH STANDARD DETAIL, TPP-03. ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 Raleigh, NC 27617 A ft/ftl IIWr/ftW Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION AMea I -Ire rrotectlon 80 Rupert Rd. Raleigh, NC 27603 CN N O 2 n� nW' W � � O O N �U •C Z E W coI c / I..L O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION LANDSCAPE PLAN - STREET LEVEL L5e0l Construction Documents DO NOT PRUNE LEADER. PRUNE OR CUT ONLY DEAD OR UNHEALTHY BRANCHES PROVIDE STAKING IF SPECIFIED. IF STAKING IS PROVIDED, PROTECT TREE WITH BROAD STRAP OR FLEXIBLE TUBING. ALLOW FLEXIBILITY IN STRAPS TO DEVELOP TRUNK TAPER. PROVIDE TURN BUCKLE AND WARNING FLAGS. REMOVE ALL STAKING AND ACCESSORIES WITHIN ONE YEAR FROM PLANTING. THE ROOT FLARE SHALL BE PLANTED AT GRADE, NO HIGHER THAN 2" ABOVE GRADE, AND NEVER BELOW GRADE. REMOVE EXCESS SOIL TO EXPOSE THE ROOT FLARE AT GRADE. TREE SHALL BE SET PLUMB MULCH DEPTH T. KEEP MULCH 3" FROM ROOT FLARE AND DO NOT CONTACT STEM HIGH QUALITY SOIL MIX AS SPECIFIED WATER SAUCER, IF SPECIFIED, SHALL RISE NO MORE THAN 3" ABOVE GRADE. COMPLETELY REMOVE TOP HALF OF BURLAP, LACING STRAPS, NAILS AND WIRE BASKET AND DISCARD FROM HOLE. ALL SYNTHETIC BURLAP MUST BE REMOVED FROM SIDES OF ROOT BALL ROOT BALL SHALL BE PLACED DIRECTLY ON COMPACTED SUBGRADE. HANDLE TREE BY THE ROOT BALL ONLY. 3X ROOTBALL DIAMETER CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE DRAINAGE OF ALL PLANTING PITS. (POSITIVE DRAINAGE AWAY FROM PIT) 2. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 3. STREET TREES MUST BE 3" CALIPER AT INSTALLATION WITH A5' MINIMUM FIRST BRANCH HEIGHT. 4. PLANTING SEASON OCTOBER - APRIL. 5. A TREE IMPACT PERMIT IS REQUIRED. 6. ELECTRICAL OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE PLANTING AREA IMMEDIATELY SURROUNDING THE TREE. 0 TREE PLANTING (CITY OF RALEIGH STANDARD) 1 SCALE: NTS TYPICAL EDGE OF PLANT BED ATYPICAL SPACING IN CURVILINEAR PLAN BEDS, OUTSIDE ROW TO FOLLOW CURVE AS SHOWN ON PLAN + + TYPICAL EDGE OF BUILDING + FINISHED GRADE + l +—+-+ +I + '� rA + ++ + + + + + + + + + + SPECIFIED O.C. SPACING (SEE PLANT SCHEDULE) 6" MIN. AMENDED SOIL SPECIFIED O.C. SPACING (SEE PLANT SCHEDULE) 1/2 OF SPECIFIED O.C. SPACING NOTES: 1. PLACE PLANTS IN PREPARED BED AS SHOWN 2. SPACING AS SPECIFIED IN PLANT LIST 3. AMEND SOILS WITH SHRUB/FLOWER BED MIX PER SPECIFICATIONS 04 GROUNDCOVER PLANTING SCALE: 3/8"=1'-O" O O M LO O CV O CV CV 00 3" (8 CM) BARK MULCH PLANTING MIXTURE (SEE SPECS) NOTE: SEE TREE MULCH 3" DEEP MAX. AND 3" MIN. FROM THE PLANTING DETAIL BASE OF THE TREE SIDEWALK PAVING AND SUBBASE * (D PLANTING SOIL MIX AS SPECIFIED z _ 4" DIA. PVC PIPE WRAPPED IN FILTER 5 —III=1 III FABRIC AND CONNECTED TO STORM a —I=III=III—III— _ — DRAINAGE SYSTEM WHERE APPLICABLE SECTION COMPACTED OR UNDISTURBED SUBGRADE NOTES: 1. A SITE SPECIFIC PLAN MUST BE DEVELOPED TO ENSURE THAT: 1.1. EACH TREE IS PROVIDED A MIN. ROOT -ACCESSIBLE SOIL VOLUME OF 600 CUBIC FEET. 1.2. THE TREE ROOT AREA BENEATH THE SIDEWALK IS EXPANDED TO MAXIMIZE ROOT ACCESSIBLE SOIL SPACE UNDER THE PAVEMENT. 1.3. CONNECT SOIL SPACE FOR ROOT EXPANSION WHERE POSSIBLE TO ALLOW ROOT SYSTEMS OF TREES TO OVERLAP AND COLONIZE A SHARED SOIL SPACE. 1.4. ANY COMBINATION OF STRUCTURAL SOILS, SOIL CONTAINMENT SYSTEM (e.g., SILVA CELL), OR ROOT CHANNELING (e.g., SOIL STRIP DRAINIAERATION SYSTEM) THAT PERFORMS AS SPECIFIED IS ACCEPTABLE. 3. 40' X 6' WIDTH MINIMUM APPLIES TO BOTH STRUCTURAL SOILS AND SUBSURFACE SOIL CONTAINMENT SYSTEMS. 4. SUBSURFACE APPLICATION SHALL BE REVIEWED AND APPROVED BY CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES URBAN FORESTRY DIVISION PRIOR TO INSTALLATION. ,1 ROAD �� ROAD STRUCTURAL SOIL SYSTEM AINMENT SYSTEM ROOT CHANNELINGIPATH CITY OF PALEIGH STANDARD DETAD. CONTACT INFORMATION: REVISIONS a+rE — e Wsc CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT TREE PLANTING IN URBAN FORESTER: TREES@RALEIGHNC.GOV SIDEWALK WITHIN ROW WWW.RALEIGHNC.GOV TPP-07 02 TREE PLANTING IN SIDEWALK WITHIN ROW (CITY OF RALEIGH STANDARD) 03 SCALE: NTS PRUNE PROPORTIONALLY — TO COMPENSATE FOR REDUCTION OF ROOTS AND TO PROMOTE NATURAL CHARACTER OF GROWTH 3" (8 CM) BARK MULCH; DO NOT PLACE MULCH WITHIN 3" OF TRUNK/STEM. FORM 2" DEEP SAUCER 3 PLANTING SOIL MIX — BACKFILL TO BE COMPACTED BY SOAKING WITH WATER AND OR LIGHTLY HAND TAMPED. SHRUB PLANTING SCALE: 3/8"=V-0" DUDA I PAINE ARCHITECTS TOP OF ROOT BALL SHALL OWNER BE 1" HIGHER THAN ADJACENT FINISHED GRADE. Narsl Properties 10020 Sellona Street, Suite 100 1 —CUT & REMOVE BURLAP Raleigh, NC 27617 FROM 1/3 OF ROOT BALL ARCHITECT Duda I Paine Architects, PA 333 Liggett Street \ Durham, NC 27701 CIVIL ENGINEER 6" MIN. McAdams 2905 Meridian Parkway, �� Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design � PLANTING SOIL MIX 555 Fayetteville St I Suite 300 �i //��//��//��//��//��/// �/% TO BE TAMPED TO AVOID SETTLING Raleigh, NC 27601 TWICE ROOT BALL WIDTH MIN. SUBSOIL BROKEN WITH PICK MEP ENGINEER WIDTH OF PLANTING HOLE SHALL BE 3 TIMES THE ROOT BALL DIAMETER IN HIGHLY COMPACTED OR CLAY SOIL; 2 TIMES THE ROOT BALL DIAMETER MINIMUM IN ALL OTHERS GENERAL LANDSCAPING NOTES 1. CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 2. LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 3. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 4. ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 5. THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 6. VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 7. CONTRACTOR TO ENSURE PROPER STABILIZATION AND SEEDING OF THE SITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 8. LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF "AMERICAN STANDARD FOR NURSERY STOCK" AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 9. ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT. 10. ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 11. ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 12. ANY EXISTING PLANT MATERIAL WITHIN THE LIMITS OF DISTURBANCE AND/OR NOTED AS TO BE RETAINED THAT IS DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE REPLACED AT THE OWNERS EXPENSE. 13. REFER TO SPECIFICATION FOR MORE INFORMATION ON DELIVERY, STORAGE AND HANDLING OF PLANT MATERIAL, QUALITY ASSURANCE, PRODUCTS AND MATERIALS, SOIL TESTING AND AMENDMENTS, INSTALLATION, MAINTENANCE AND WARRANTIES, AND ADDITIONAL PLANTING REQUIREMENTS. 14. ALL AREAS CALLED OUT AS MULCH AND ANY ADDITIONAL DISTURBED AREAS NOT SCHEDULED FOR SOD SHALL BE MULCHED WITH MINIMUM 3" DEPTH SHREDDED BARK MULCH. 15. STRUCTURAL SOIL SHALL BE 'CU STRUCTURAL SOIL' OR APPROVED EQUIVALENT SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH — PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 CN 4) 2 4-1 nWl W � O mot,! O N MU� V/ Z E a� Cn lcl::� 0 *__o This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION LANDSCAPE DETAILS L5e02 Construction Documents CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER .614 1r1 C a / / I 'I • i1 r+ eT L Yi't_yri , F 1 Appendix B Grading Plan hart ` hickman SMARTER ENVIRONMENTAL SOEVr1ONS I U, / T-------------------- - - - - - - - - - - - - - - - - - -- -T -- \-T----- / 1--- - - - - - - - _ I =--------- -�° _- na nno-------------/-_-J- ----�-� - - - - - - - - - -------- --_ - / 7 -- �- no no no no no - - no no �il:� o - - / - - - - - - rrN� w w w w n0-ono- no noc- 1--------T------ - \ -� w w w w----=-f===�= T�- -__�_° _ no no no _- ----- W \� T w w w wow w- \� o`"---_- n�� -no_� no - no �� \ SSMH -w w w w w \ w w w w �� w w - y -� w w w w \ EX-C6100 N � \ `RIM=314.86 � w ' � ��\ w � � EXIST \ /v I F \ 6 CLAY(E)�309.59 EXISTING = D� � v 6"CLAY W =30-.69 � �� � � � CRATE 311.04� � I \ � ( ) �� � . .1:� 15"RCP�f�)=308.98 / 0IR ST / -- - - - - - -- --\ = ----- - -- _ MAIN STREET EIN P15"RCP (S) =�� 8. 9 9 s s / r _ r ARALLEL PARKING / / '��/ �/Oi - _ ss- » � � t --- -�66 ---PUBLIC R _w- -- --- N � F , / '�/ / � I -�- S�-� =,Z--sue- - - ---- - I I I I GRADING LEGEND m FLARED END SECTION U ENDWALL SECTION CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN Q JUNCTION BOX DRAINAGE FLOW ARROW r.. LINE BREAK SYMBOL 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS /317.36 (PRIMARY.STREET)I �TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION 316.86-MG � J >>> / / (NOTE: BOTTOM OF WALL IS GROUND ai an / / ��� ELEVATION NOT WALL FOUNDATION) /F / 311.42 MG f / / o 1/1 ADJUST EX. MANHOLE RIM i 61 LF 15" RCP o 1 /r 317.27 r I / 19 LF 12" HDF£ o / WW W TO FINISHED GRADE i @ 1 08% + 250.60 SPOT ELEVATION 317.36 / o 0 1.07% / >>> i N I / 317.36 316.77- L _o / 316.18 / / / / + 250.60-MG MATCH EXISTING GRADE °1 L_ m o ai 315.68-MG I / / 31 1.97-MG 317.68 °1 ai al / I I S 311.75 a-i 01 0 � o !- I i 9 STORM DRAINAGE m i 311.25 I 317.18 MG 01 a� J-..�� � �,, � 312.83 312.48 � m on STORM SERVICE LINE N ( I' m m a,312.33-cG m 311.98-MG 311.42 ' f - a . 01 °1 a� y -_ 311.42 ROOF DRAIN, 8" ADS I a - - �J� -- -- - - -- -- - 0 - o - o- - RD- RD- RD- i � � O � 1 NON -PERFORATED TUBING OR I / 317 27 a S 87° , „ \ v �� L - EQUAL 1.0% MIN. SLOPE 3' MIN. F - - _ _ 4 2 7 E A"O1 �'� \ 4 I O T 1 3j2 �2 9 �, COVER PVC SCHEDULE 40 IN ' I \ 210.53 (TOTAL _ 102 F 12" HDPE I - TRAFFIC AREAS I \ 317.62 VARIABLE WIDTH SIDEWA - �� 1' 8% i'� 312.43 3 - --TP-TP-TP- TREE PROTECTION FENCE 317.12-M6 �� 317.37 ACCESS EASEMENT �O V 13 LF 312.43 311.54 ti - JB m ] v - - _ ❑ \ (F � - - 1 1.54 LD LD LIMITS OF DISTURBANCE an 31727 AD-202 v \ [j3�1 a- - ---- -- -- - - - - - - -_L- - --❑- - -- r- -C'0 -200� ---------- 3[1 i I\I I9II2 - -0-- \ - - - - WOODED AREA - - - - - - - - - - - - - - BS 12.62 312.49 ---------31339g31.0250 MAJOR CONTOU R IE 252 -- 315.48 - MINOR CONTOUR T3 EXISTING T SPS 250 RIGHT-OF-WAY I I ______--- MAJOREXISTING /LLJ 315.8 o R P 312.81 317.38 313.39 312.31 312.74 II(XI _____252 _EXISTING MINOR CONTOUR I 312.24 c, 3 3.9 312.56 EASEMENT LINE314.65 No u' 020' 314.65 -RAMUP I INTERNAL RAMP \315.50 BUILD -TO LINB ACCESSIBLE PARKING AREA LO (2% MAX. SLOPE IN ALL DIRECTIONS) I NIO 1317.45 I \ UP T-I OF / DIM�TURBANCE 317 1317.14-M('w \ 13� A 315.45 I' BUILDING --- I FFE=315.50 / � 72 LF 15" RCP c, / / 1 I I / z 0 1.04% I i �� 315.50 I / - - � (I4)-SLEEVES hN CURB o o I I 19 UTLETS FOR/ 4" PVC o I I h I __ VAR' BLE WI TH PRIVATE I RAIN PIPES - - J m \ __ _DR7 AGE E SEMENT I I / '� I I I- / (STO MWAT R B I I I I I I SS & AINTENAN E) 317.1 I 19 n 6 / INV.=316.18 ICI I I / INV.=316.17 I 317.25 (4)-4" PVC DRAIN PIPES I / 1 ® 1.0% MIN. SLOPE FOR BACKFLOW PREVENTER INV.-316.1 6 EMERGENCY OVERFLOW INV.=316015 LD INV.=316.50 / \ I I I III to I I I FFE=316.80 o I I I 1 I I 1 I \ / ROW I 316.70 \ o I I I N II II II II / I / � 316.58 \ I I \ r----------- I X I 9 � / � I,l \ 1 I I I 316.80 // \ I VARIABLE WIDTH PRIVATE cr) I I I DRAINAGE EASEMENT I I I I \I 11 I I IV I I� I I (STORMWATER BMP ACCESS AND I LIMITS OF316.48 ram MAINTENANCE) DISTURBAN CE T11, _JI__I__L 8F-w I III I J I11 316.80 I I I / 1316.23 I 1 \ �- CONNECT\TO'INTERNAL 315.73 M j 1 U ROOF DRAINAGE COORDINATE WITH JB-102 I I I I PLUMBING PLANS _ I i 16.80 / - / \ ®1191 RCP I_1 FFE=316.80 \ SF -OUT I I I I I I I I I I 1 31 .54 I I I I I I I I 315.8 316.12 I I I I / � I I 315.3 -MG 316.05-1-_J__I___j 31 .44 _ UNDERGROUND STORM 1 �I I9 �_L � I I FILTER VAULT hn RIM=MATCH FINISHEDI GRADE I Ir ) I I I I OF PARKING DECK I x I I I I I I II I 316.10 i\ SEE DETAIL ON SHEET C9.00 s ----- _ 31 6.20-MG L� _ I I - - - -X-X-X-xX����f7 �X87 �(�_L"� ��T��I� LD--- --- ------ - LD 315.95-MGLD LD J / - LD -- L°-- �� --LD --- - - _--------- i I I DISTURBED AREA =0.70AC. I1 i I �-316.00-MG // /// LD LDLD LD LD LD - LD --� ---�- - - - - - - - - - - - - - - - - __ __ I � / �j I I I- - / � TEMPORARY CONSTRUCTION �- � LD LD LD LD � - - - - - � 9 CD/ I 11 "t" I I I I 1 - - - - -- -- EASEMENT I LD LD � LD - SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE, AND UTILITY NOTES ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST5 VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT, THE ENGINEER AND A REPRESENTATIVE OF THE OWNER. 6. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 7. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY GRAPHIC SCALE DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 0 5 10 20 8. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. linch =loft. P. 7 CD CD M Lf) CD N CD N N 00 Know what's below. Call before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All Construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: CITY OF RALEIGH DEVELOPMENT APPROVAL CITY OF RALEIGH REVIEW OFFICER DUDA I PAINE ARCHITECTS OWNER Narsi Properties 10020 Sellona Street, Suite 100 1 Raleigh, NC 27617 Duda I Paine Architects, PA 333 Liggett Street Durham, NC 27701 CIVIL ENGINEER McAdams 2905 Meridian Parkway, Durham, NC 27713 STRUCTURAL ENGINEER Scalene Design 555 Fayetteville St I Suite 300 Raleigh, NC 27601 MEP ENGINEER Barrett Woodyard 2301 Rexwoods Drive, Suite 108, Raleigh, NC 27607 FIRE PROTECTION Allied Fire Protection 80 Rupert Rd. Raleigh, NC 27603 N O 2 N N O This document is the product and exclusive property of Duda I Paine Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Duda I Paine Architects, PA. © Copyright 2020 Duda I Paine Architects, PA MARK I DATE I DESCRIPTION DETAILED GRADING PLAN C 601 Construction Documents CB TOP=319.58 15"RCP(E)=316.3& 15"RCP(S)=316.74 (2)15"PVC(W)=316.43 DI GRATE=319.07 15"RCP(N)=316.i\' WV �! I f I I f I I � I I f I I I I I TO :318.40 15"RCP(E =315.6 I I 15"RC '(W =315.7 I F -i SD S I/ I � I I �- I I - I / TR TR L _ I I I I T--- - - - - - - i-------------------- - -7 � - w�w w 1 -- - - �RT\ -\-\ =II=I w -w -\= \- ---w wow w--�W ww w w w w ww \ w w w w SATE=311.�4 15"RCP (S)=3Q,,8.99 - - - - - - - - - - - - - - - - - - - .a7i 0.09 o.os - 0. 04 0.08- 0.�4 0.08 0.19 0.29 0.23 0.23 0.26 0.3 ��l O0. 0.3�1 0.28 0 0.10-. 2 ® I J , ❑ 0. 0.08 0.24 .43 0.41 0.59t0.48 0.30- 0.28 0.130.18 + u.v� 0.03 0.09 0.14 0.1+ 0.02 0.09 0. \ 0.1 7B 0.9!} 0.98 0.9 3?� \ . II I + 0.28- 0.00- 0.00- 0.00- 0.00- 0.08- �28 .I64 0.85- 0.83- I0.93110.60- 0.32- 0.23- 0.1 s- 0.0+ 0.0 s- 0.33- 0.39- 0.53- 0.63 �\\ 4 0.9s 0.96 1.02 1.1 + 1.2-+1.30.4& 1.4+ 1. 1.2 0. 0.44 0.38- 0.38- 0.23 + 0.79- .44 0.0 .00- 0.16- 0.29-� 0.39- 0.34 4 1.00- O.t�� �.16- 0.30- 0.24 0.24 0.19- 0.14 0.0 0.1 + 0.2,1- 0.40- 0.44 0.59- 0.7+ 0.84 0.96- 1.10- 1.29E 1.40- 1.5+ .69- 1.6£ 1.6& 1.53- 1. EF1.2 0. 8- 0.49- 0.46- 0.39- 0.4 1. 0- 0.38- 0.00- 0. 0- 0.06- 0.3+ 0.4+ 0.33- .32- 0.64 0.01E 1.S2-0.42- 0.3+ 0.32- 0.25- 0.14 0.00-\13- 0.28- 0.36- 0.5+ 0.63- 0.73- 0.92- 1.p-+ 1.2& 1.38- 1.4& 1.61E .7& 1.79 1.6& 1.74 1. 1.2 0 4 0.59- 0.6+ 0.64 0.6 + 1 0- 0.29- 0.00- . 0.88- 0.69- 0.5+ 0.32- 0.1 + 0.13- 0.3+ 0� 84�0.52- 0.44 0.36- 0.24 0.1 + 0.02- 0.18�0.29- 0.45- 0.6+ 0.76- 0.9+ 1.Og i.1-+1.31E 1.48- 1.58- 1.6-+ 78- 1/8+ 1.93- 1.99- 1. + 1.4& 9+ 0.86- 0.9+ 0.92- 0.9 ,,III \ \� + 1 0 0.22- 0.0 0 02- 0.7+ 0.50- 0.30- 0.10- 0.02- 0.10- 0.02- y1.38- 0170- 0.48- 0.35-0.22- 0.08- 0.03- 0.24 0.% 0.46- 0.62- 0.75-0.88- 1.00- 1I.13-1.33-1.5+ 1.72- 1.8& 1.9 2.03 2.3+ 1.9 1.4 .28 1.31E 1.34 1.32 1.3 I � II + 1 0 8 .65- 0.78- 0.56- 0.33- 0.13- 0.03- 0.20- 0.3+ 0.39- i.44 0.84 0.46- 0.30- 0.16- 0.04 0.13- 0.25-0.34 0.42- 0.53- 0.66- 0.8+ 0.99- 1I.1-+1.38- 1.61E 1.82- 2.00 / 10- 2.2+ 2.4 2.48- 2.0+ 1.6-+.6 + . 0. .82- 0.58- 0.34 0.02 IQ.24 0.9410.45-0.24 0.09- 0.04 0.12- 0.2+ 0.28- 0�3- 0.48- 0.63- 0.85-1.0& 1I2+ 1.4-+1.6& 1.9+/- .12- 2.33- 2.44 2.42- 44 2.23- 1.8 1.89-1.9+ 1.9& 1.92- 1.9 / / I + .9 0. 0.69- 0.80- 0.74 0.74 0.78- 0.83- 0.98- 1.1 + 1.2 U.2s 0.98- 0.43- 0.24 0.10- 0.0+ 0.09- 0.18- 0.23- 0.35-0.42- 0.6+ 0.86- 1.08- 1.2+ 1.7+ 1:/2 8.18- 2.36- 2.38- 2.39- 2.44 2. 2.3+ 2.0 2.12- 2.13- 2.13- 2.14 2. .9 0. 0.62- 0.74 0.86- 0.93- 1.021- 0.93- 016- 0.24 0.12- 0.03- 0.05- 0.13- 0.24 0.28- 0..30`0.44 0.68- 0.9t 1.2& 1.93 /2.24 2.33- 2.35- 2.36- 2.38- 2.4+ 2.4 2.43- 2. 2.32- 2.32- 2.34 2.3+ 2. 1 1 / I I / 9� .0 0.05- 0.18- 0.2+ 0 36- 0.05- 0.03- .3+ 0.50- 0.5+ 0.68- 0.78- 0.82- 0.43- 0.22- 0.14 0.06- 0.02- 0.10- 0.18- 0.2+ 0.34 0.42- 0.63- 0.94 1.3+ �04 2.33- 2.34 2.36- 2.38- 2.4+ 2.42- 2.44 2. 8 i t .9 O.O+ 0.18- 0.24 0 4 0.51- 0.43- 0.4+ 0.4+ 0.42- 0.43- 0.5s- 0.69- q.34 0.1 g 0.0& 0.08- 0.08- 0.18- 0.2g 0.33- 0.44 0 58- 0.74 1.0 1.4� i 14C 2.44 2.43- 2.48- 2.48- 2.5+2.53- 2.58- 2.64 2 2- 2.6+ 2.5�1- 2.54 2.5+ 0 23- .0 0.04 0.14 0.22 34 0.51- 0.49- 0.43- 0.42- 0.40- 0.33- 0.42- 0.4i /0.l+ 0.09- 0.04 0.08- 0.13- 0.20- 0.2+ 0.34 0.42- 0%58- 0.7+ 1.0T 1.48- {18-\ ,48- 2.4+ 2.43- 2.45- 2.48- 2.58- 2.58- 2.5+ 8- 2.55- 2.52- 2.49- 2.4+ .20- 1.0 ` 0.02 0.10- 0.2+ C 2+ 0.62 0.52- 0.43- 0.46- 0.46- 0.4+ 0%3*'0.30- 0.19- 0.06- 0.03- 0.14 0.28- 0.23- 0.33- 0.44 0.47 0.55- 0.73- 1.4 1.48- ?.h 5- 2.3 2.38- 2.48- 2.43- 2.45- 2.49- 2.58- 2.55- .53- 2.5+ 2.43- 2.44 2.44 .1 ()- 1.00-\ 23- 0.0+ 0.18- .28- 0.63- 0.54 0.50- 0.49- 0.43- 0.46- O.43- 0.30- 0.19- 0.08- 0.03- 0.14 0.19- 0.29- 0.39- 0.43- 0 554 0.7+ 0.94 1.1 � 4& 1.16- 2.3+ .3+ 2.38- 2.40- 2.43- 2.4+ 2.54 2.54 .48- 2.45-2.42- 2.3+ 2.35- 0.40.04 O.ls0.220.2 .590.5+ 0.590.480.41C.480.390.220.080.00.120.20.2s0.36 T} 58 2.48 2.342.35- 2.38 2.42 2.48 2.48 2.4 .43 2.48 2.31 2.34 2.38+ 0 \9g 1. .3 0.80- 0.48- 0.01- 0.0+ 0.1 + 0.03- .24 0.40- 0.42- 0.49- 0.4t 0.42- 0.44 0.34 0.14 0.02- 0.13- 0.24 0.29- 0 38- 0.45- 0.64 0.84 1.02- 1 h9- 1.72- 2\..4 2.40- 2.322-\2.3+ 2.36- 2.43- 2.44 2.44 44 2.38- 2.35- 2.32- 2.29- 2.25- ' I + 0.63- 0.59- 0.23- 0.10- 0.0+ 0.05- 0.1 + .1 a 0.28- 0.23- 0,2+ 30- 0.30- 0.2+ 0.20- 0.13- 0.06- 0.12- 0.22- 0.30- 0.39- 0.49- 0.59- 0.75- 0.99- 2 ! 23-1.6& 1E 1.91.8+ 2.06- Z.25- 2.36- 2.44 2.48- 2.3 2.36- 2.33- 2.3+ 2.23- 2.23- 2.2+1 . ��I�1 + 0.33- .35- 0.08- 0.06- 0.02- 0.0+ 0.09- .00.1 + 0.10- 0.09- 0.08- 0.03- 0.0+ 0.0+ 0."..13- 0.24 0.34 0.44 0.54 0.64 0.74 0.9+ 1 .� + 1.31E 1.52- 1.7+ 1.93- 2.16- 2.34 2.35- 2.36- 2.34 2.34 2.28- 2.25- 2.22- 2.18- 2.131 9 I I I 11 I + 0.13- 08- 0.0()- 0.0+ 0.02- 0._Q+ " .14 0.04 0.04 0.06- 0.1 + 0.12- 0.13- 0.14 0,4-9�-0.2+ 0.22- 0.30- 0.39- 0.49- 0.59- 0.68- 0.78- 0.88-/1.0+ 1.2+ 1.4+ 1.6+ 1.8+ t.0+ 2.18- 2.24 2.23- 2.24 2.24 2.23- 2.2+ 2.1 + 2.13- 2.18! 0 1.01E 1.1 1.33- 1.51E 1.6-+ 1.8+-�61 2.06- 2.08- 2.08- 2.08- 2.09- 2.09- 2.09- 2.08- 2.0 Q 1 - /I ---------_= j I "j f I I I III -------- LLI I F I I I I I I I F I I-----------------------J I II I � I I I I I I � I I II I f la I� w w w w W- General Revision number 0 Number of points 22161 Minimum X coordinate 2107260.000' Minimum Y coordinate 736282.000' Maximum X coordinate 2107475.000' Maximum Y coordinate 736393.000' Minimum elevation-1.240' Maximum elevation 2.651' Mean elevation 0.711' Grid X spacing 1.000' Y spacing 1.000' OrientationNO'00'00.00"E Volume Base Surface Ex. Surface Comparison Surface Pr. Surface Cut Factor 1.000 Fill Factor 1.000 Cut volume (adjusted) 101.45 Cu. Yd. Fill volume (adjusted) 675.98 Cu. Yd. Net volume (adjusted) 574.53 Cu. Yd.<Fill> Cut volume (unadjusted) 101.45 Cu. Yd. Fill volume (unadjusted) 675.98 Cu. Yd. Net volume (unadjusted) 574.53 Cu. Yd.<Fill> 0 GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. 'J McADAMS The John R. McAdams Company, Inc. One Glenwood Avenue Suite 201 Raleigh, NC 27603 phone 919. 823. 4300 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT DUDA PAINE ARCHITECTS 333 LIGGETT STREET DURHAM, NORTH CAROLINA 27701 PHONE: 919. 688. 5133 IDUDA j PAINE ITECTS J W Q � � H � N w H H N cH W z 0 G � =a REVISIONS 9 i NO. DATE 1 11-05-2019 REVISED PER CITY OF RALEIGH COMMENTS 2 01-30-2020 REVISED PER CITY OF RALEIGH COMMENTS 3 02-04-2020 REVISED PER CITY OF RALEIGH COMMENTS 4 04-08-2020 REVISED PER CITY OF RALEIGH COMMENTS PLAN INFORMATION PROJECT NO FILENAME CHECKED BY DRAWN BY SCALE DATE SHEET DPA-17010 DPA17010x 07. 15. 2019 EARTHWORK ANALYSIS EX-1