HomeMy WebLinkAbout23070_Red Carpet Inn_EMP_20211013
01671-003/00322972
1
EMP Version 2, January 2021
NORTH CAROLINA BROWNFIELDS PROGRAM
ENVIRONMENTAL MANAGEMENT PLAN
This form is to be used to prepare an Environmental Management Plan (EMP) for projects in
the North Carolina Brownfields Program at the direction of a Brownfields project manager.
The EMP is a typical requirement of a Brownfields Agreement (BFA). Its purpose is to clarify
actions to be taken during the demolition and construction at Brownfields properties in an
effort to avoid delays in the event of the discovery of new contamination sources or other
environmental conditions. The EMP provides a means to document redevelopment plans and
environmental data for each applicable environmental medium to inform regulatory-compliant
decision-making at the site. As much detail as possible should be included in the EMP,
including contingency planning for unknowns. Consult your project manager if you have
questions.
Prospective Developers and/or their consultants must complete and submit this form and all
pertinent attachments, see checklist below, to their Brownfields project manager prior to any
earthmoving or other development-related activities that have the potential to disturb soil at
the Brownfields Property, including demolition. For the resultant EMP to be valid for use, it
must be completed, reviewed by the program, signed by all parties working on the project,
and approved by the Brownfields project manager. Failure to comply with the requirements of
the EMP could jeopardize project eligibility, or in the event of a completed agreement, be
cause for a reopener.
The EMP is valid only for the scope of work described herein and must be updated to be
applicable for new phases of redevelopment or after significant changes in applicable
regulatory guidance.
Voluntary Metrics Tab
The NC Brownfields Program updates estimated capital investment (from the Brownfields
Property Application) and estimated jobs created (from the Brownfields Agreement) whenever
possible. As a voluntary measure, you may opt to complete the below information for capital
investment and jobs created as estimated by your final redevelopment plans for the Brownfields
Property:
1. Estimated capital investment in redevelopment project: Click or tap here to enter
text.
2. Estimated jobs created:
a. Construction Jobs: Click or tap here to enter text.
b. Full Time Post-Redevelopment Jobs: Click or tap here to enter text.
01671-003/00322972
2
EMP Version 2, January 2021
Table of Contents
NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN ........................... 1
GENERAL INFORMATION ........................................................................................................................ 5
COMMUNICATIONS ................................................................................................................................ 5
NOTIFICATIONS TO THE BROWNFIELDS PROGRAM ............................................................................... 6
REDEVELOPMENT PLANS ........................................................................................................................ 6
CONTAMINATED MEDIA ......................................................................................................................... 8
PART 1. Soil ......................................................................................................................................... 9
PART 2. GROUNDWATER .................................................................................................................. 19
PART 3. SURFACE WATER .................................................................................................................. 21
PART 4. SEDIMENT ............................................................................................................................ 22
PART 5. SOIL VAPOR ......................................................................................................................... 22
PART 6. SUB‐SLAB SOIL VAPOR ........................................................................................................ 23
PART 7. INDOOR AIR ......................................................................................................................... 24
VAPOR INTRUSION MITIGATION SYSTEM ............................................................................................. 24
CONTINGENCY PLAN – encountering unknown tanks, drums, or other waste materials ..................... 25
POST‐REDEVELOPMENT REPORTING..................................................................................................... 28
APPROVAL SIGNATURES ....................................................................................................................... 30
LIST OF ATTACHMENTS:
Exhibit 1 – NCBP Diagram for Temporary Containment of Impacted or Potentially Impacted Soil
Exhibit 2 – Topographic Map
Exhibit 3 – Redevelopment Plans
Exhibit 4 – Grading / Cut and Fill Heat Map
Exhibit 5 – Soil Sample Location Map w/ Grading Overlay
Exhibit 6 – Groundwater and Soil Vapor Sample Location Map w/ Redevelopment Overlay
Exhibit 7 – Proposed Final Grade Sample Locations
Exhibit 8 – Preliminary Construction Schedule
Table 1 – Summary of Historical Soil Analytical Results (Pre-2020)
Table 2 – Summary of Historical Groundwater Analytical Results (Pre-2020)
Table 3 – Summary of Historical Soil Analytical Results (2020)
Table 4 – Summary of Historical Groundwater Analytical Results (2020)
Table 5 – Summary of Historical Soil Gas Analytical Results (2020)
Table 6 – Summary of Historical Soil Gas Analytical Results (2021)
DEQ Risk Calculator – Vapor Intrusion –Soil Gas to Indoor Air (Residential; 2020 and 2021)
01671-003/00322972
3
EMP Version 2, January 2021
So that the EMP provides value in protecting brownfields eligibility and public health, the
preparer shall ensure that the following steps have been completed prior to submitting the
EMP for review. Any EMP prepared without completing these steps is premature.
☒ Site sampling and assessment that meets Brownfields’ objectives is complete and has
been reviewed and approved by the Brownfields Project Manager.
☒ Specific redevelopment plans, even if conceptual, have been developed for the project,
submitted and reviewed by the Brownfields Project Manager.
The proposed redevelopment (“The Radius Dilworth”) will consist of two multi-family
structures, hereafter referred to as the Enclave Building and the Overlook Building.
The Enclave building will be an eight-story structure containing solely multi-family
rental apartment units and the associated amenities (e.g. swimming pool). The
Overlook building will be a 26-story high-rise residential tower that will also contain a
parking garage and commercial (e.g. office/retail) space on the first floor.
Excerpts of the development plans (architectural plans showing the building
footprints and select elevations) are provided as Exhibit 3.
Please submit, along with the completed EMP form, the following attachments, as relevant
and applicable to the proposed redevelopment:
☒ A set of redevelopment plans, including architectural/engineering plans, if available; if
not conceptual plans may suffice if updated when detailed plans are drafted.
☒ A figure overlaying redevelopment plans on a map of the extent of contamination for
each media.
☒ Site grading plans that include a cut and fill analysis.
Grading plans for the redevelopment are included in Exhibit 4.
☒ A figure showing the proposed location and depth of impacted soil that would remain
on site after construction grading.
☒ Any necessary permits for redevelopment (i.e. demolition, etc.).
Permits for redevelopment have not been yet been obtained. Applicable permits will be
provided to the Brownfields Program upon their receipt.
01671-003/00322972
4
EMP Version 2, January 2021
☒ A detailed construction schedule that includes timing and phases of construction.
A proposed construction schedule is provided as Exhibit 8.
☒ Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas,
etc.) applicable to the proposed redevelopment.
☒ Figures with the sampling locations and contamination extents for each impacted media
applicable to the proposed redevelopment.
A map showing the locations of historical soil, groundwater, and soil vapor samples with
to footprint of the proposed development is provided as Exhibits 5 and 6. Summaries of
the corresponding analytical data are provided as Tables 1 through 6.
☒ A full final grade sampling and analysis plan, if the redevelopment plan is final.
☐ If known, information about each proposed potential borrow soil source, such as aerial
photos, historic site maps, historic Sanborn maps, a site history, necessary for
brownfields approval.
☐ Information and, analytical data if required, for quarries, or other borrow sources,
detailing the type of material proposed for importation to the Brownfields Property.
☐ A work plan for the sampling and analysis of soil to be brought onto the Brownfields
Property. Refer to Issue Resolution 15 in Brownfields Program Guidelines.
☐ A map of the Brownfields Property showing the location of soils proposed for export
and sampling data from those areas.
☐ If a Vapor Mitigation System is required by the Brownfields Program, the Vapor
Intrusion Mitigation System (VIMS) plan will be signed and sealed by a NC Professional
Engineer. The VIMS Plan may also be submitted under separate cover.
01671-003/00322972
5
EMP Version 2, January 2021
GENERAL INFORMATION
Date: 9/13/2021 Revision Date (if applicable): 10/13/2021
Brownfields Assigned Project Name: Red Carpet Inn
Brownfields Project Number: 23070-19-060
Brownfields Property Address: 615 East Morehead Street, Charlotte, Mecklenburg County, North
Carolina
Brownfields Property Area (acres): 2.83 acres
Is Brownfields Property Subject to RCRA Permit?.......................☐ Yes ☒ No
If yes enter Permit No.: Click or tap here to enter text.
Is Brownfields Property Subject to a Solid Waste Permit….……..☐ Yes ☒ No
If yes, enter Permit No.: Click or tap here to enter text.
COMMUNICATIONS
A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers
that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the
EMP shall be maintained at the Brownfields Property during redevelopment activities. NOTE, THE EMP
DOES NOT TAKE THE PLACE OF A SITE-SPECIFIC HEALTH AND SAFETY PLAN.
Prospective Developer (PD): MOD CLT Property, LLC
Contact Person: Ian S. Levine
Phone Numbers: Office: 646-747-2199 Mobile: Click or tap here to enter text.
Email: ilevine@spandreldevelopment.com
Contractor for PD: Gilbane Building Company
Contact Person: Jason Mari
Phone Numbers: Office: 704-501-0963 Mobile: 724-309-2854
Email: jmari@gilbaneco.com
Environmental Consultant: Terracon Consultants, Inc.
Contact Person: Will Frazier
Phone Numbers: Office: 704-324-7375 Mobile: 336-409-0772
Email: will.frazier@terracon.com
Brownfields Program Project Manager: Bill Schmithorst
Phone Numbers: Office: 919-707-8159 Mobile: 919-441-3606
Email: William.schmithorst@ncdenr.gov
Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch,
01671-003/00322972
6
EMP Version 2, January 2021
Hazardous Waste, Solid Waste): Click or tap here to enter text.
NOTIFICATIONS TO THE BROWNFIELDS PROGRAM
Written advance Notification Times to Brownfields Project Manager: Check each box to accept
minimum advance notice periods (in calendar days) for each type of onsite task:
On‐site assessment or remedial activities: ……………………………………….…… 10 days Prior ☒
Construction or grading start: ……………………………………….………………………. 10 days Prior ☒
Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously
unknown contamination: ……………………………….……………………………………. Within 48 hours ☒
Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in
area of contamination, ventilation of work zones): …………….……….……… Within 48 hours ☒
Installation of mitigation systems: ………………………….………………….……….. 10 days Prior ☒
Other notifications as required by local, state or federal agencies to implement redevelopment
activities: (as applicable): ……………………….…………………………………………..… Within 30 days ☒
REDEVELOPMENT PLANS
1) Type of Redevelopment (check all that apply):
☒Residential ☒Recreational ☐Institutional ☒Commercial ☒Office ☒Retail ☐Industrial
☐Other specify:
The proposed redevelopment (“The Radius Dilworth”) will consist of two multi-family
structures: the Enclave Building and the Overlook Building. The Enclave building will be
an eight-story structure containing solely multi-family rental apartment units and the
associated amenities (e.g. swimming pool). The Overlook building will be a 26-story
high-rise residential tower that will also contain a parking garage and commercial (e.g.
office/retail) space on the first floor.
2) Check the following activities that will be conducted prior to commencing earth‐moving activities
at the site:
☒ Review of historic maps (Sanborn Maps, facility maps)
☒ Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility
lines, etc.
☒ Interviews with employees/former employees/facility managers/neighbors
01671-003/00322972
7
EMP Version 2, January 2021
3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if
detailed plans are not available. EMP review without such information would be premature):
Provide brief summary of redevelopment plans, including demolition, removal of building
slabs/pavement, grading plans and planned construction of new structures:
See attached drawings (Exhibit 3) for proposed redevelopment plans. An overlay of the
grading plans showing areas of cut and fill with respect to historical soil sample locations is
also available in Exhibit 5.
4) Do plans include demolition of structure(s)?:
☐ Yes ☒ No ☐ Unknown
☐ If yes, please check here to confirm that demolition will be conducted in accordance with
applicable legal requirements, including without limitation those related to lead and asbestos
abatement that are administered by the Health Hazards Control Unit within the Division of Public
Health of the North Carolina Department of Health and Human Services. If available, please
provide a copy of your demolition permit.
Demolition will be limited to removal of existing hardscape (parking lot) and associated
landscaping and utilities.
5) Are sediment and erosion control measures required by federal, state, or local regulations?
☒ Yes ☐ No ☐ Unknown
☒ If yes, please check here to confirm that demolition will be conducted in accordance with
applicable legal requirements. If soil disturbance/grading activities are necessary to install
sediment and erosion control measures, the activities will not begin until this EMP is approved.
6) Which category of risk‐based screening level is used or is anticipated to be specified in the
Brownfields Agreement? Note: If children frequent the property, residential screening levels shall
be cited in the Brownfields Agreement for comparison purposes.
☒ Residential ☐ Non‐Residential or Industrial/Commercial
Both the Enclave and Overlook buildings contain residential rental units; as such, residential
screening levels will be uses in the Brownfields Agreement.
7) Schedule for Redevelopment (attach construction schedule):
a) Construction start date: 2/22/2022
b) Anticipated duration (specify activities during each phase):
Construction is anticipated to run through September of 2024. A summary of the preliminary
schedule is attached as Exhibit 8. Building A on the attached schedule refers to the Overlook
Building (Floors 13 and up), Building B refers to the residential units wrapping around the
parking garage of the Overlook Building, Building C refers to the Enclave Building, and Building
D refers to the parking garage that is part of the Overlook Building.
01671-003/00322972
8
EMP Version 2, January 2021
c) Additional phases planned? ☐ Yes ☒ No
If yes, specify the start date and/or activities if known:
Start Date: Click or tap to enter a date.
Planned Activity:
Click or tap here to enter text.
Start Date: Click or tap to enter a date.
Planned Activity:
Click or tap here to enter text.
Start Date: Click or tap to enter a date.
Planned Activity:
Click or tap here to enter text.
d) Provide the planned date of occupancy for new buildings:
Building C (Enclave Building) is expected to be completed in December 2023, with occupancy
planned to begin early 2024. Building B (residential units of the Overlook Building that wrap
around the garage) is projected to be completed in May 2024, with occupancy planned shortly
thereafter. Buildings A and D (remainder of Overlook Building) are projected to be completed in
September 2024, with occupancy planned shortly thereafter.
CONTAMINATED MEDIA
Please fill out the sections below, using detailed site plans, if available, or estimate using known areas
of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new
construction onto figure showing contaminated soil and groundwater locations.
1) Contaminated Media on the Brownfields Property
Part 1. Soil: ……………………………………….……………. ☒ Yes ☐ No ☐ Suspected ☐ Unknown
Part 2. Groundwater: .……………………….……..……. ☒ Yes ☐ No ☐ Suspected ☐ Unknown
Part 3. Surface Water: .……………...……..…………… ☐ Yes ☒ No ☐ Suspected ☐ Unknown
Part 4. Sediment: .……………...……..…………………… ☐ Yes ☒ No ☐ Suspected ☐ Unknown
Part 5. Soil Vapor: …..…………...……..…………………. ☒ Yes ☐ No ☐ Suspected ☐ Unknown
Part 6. Sub‐Slab Soil Vapor: ……...……..…………….. ☐ Yes ☐ No ☐ Suspected ☒ Unknown
Part 7. Indoor Air: ...……..…………………………………. ☐ Yes ☐ No ☐ Suspected ☒ Unknown
2) For the Areas of Proposed Redevelopment on the Brownfields Property, attach tabulated data
summaries for each impacted media and figure(s) with sample locations.
Summaries of soil, groundwater, and soil vapor analytical data available at the site are provided in
Tables 1 through 6. The associated sample locations are depicted on Exhibits 5 and 6.
01671-003/00322972
9
EMP Version 2, January 2021
PART 1. Soil
1) Known or suspected contaminants in soil (list general groups of contaminants):
Numerous subsurface investigations have been conducted at the site since 2000 to investigate
impacts related to a release (NCDEQ Incident No. 15378) from an underground storage tank (UST)
system formerly located on the adjacent property to the northwest of the site (521 East Morehead
Street). These investigations identified low levels of petroleum constituents at depth, near the
water table. Naphthalene was identified above its protection of groundwater Preliminary Soil
Remediation Goal (PSRG) in two locations (P-1, 12 to 16 feet below land surface [bls]; and P-9, 12
to 16 feet bls), above its residential PSRG in one location (P-2, 12 to 16 feet bls), and above its non-
residential PSRG at one location along the property line with 521 E. Morehead Street (GP-9, 11 to
13 feet bls). The following constituents were also identified above their protection of groundwater
PSRG at GP-9: ethylbenzene, xylenes, isopropylbenzene, n-propylbenzene, 1,3,5-
trimethylbenzene, n-butylbenzene, and sec-butylbenzene. 1,2,4-trimethylbenzene was identified
above its residential PSRG at GP-9 as well. Other petroleum constituents or volatile organic
compounds (VOCs) were not identified above their PSRGs at the site during historical sampling
events.
In 2020, Terracon collected additional soil samples at the site for VOCs, semi-volatile organic
compounds (SVOCs), and Resource Conservation and Recovery Act (RCRA) Metals (plus hexavalent
chromium). The sole compound identified above laboratory detection limits in the samples
collected was arsenic at concentrations ranging from 0.72 milligrams per kilogram (mg/kg) to 2.6
mg/kg. While these concentrations exceed arsenic’s residential PSRG, these concentrations are
considered naturally occurring based on the magnitude, range, and frequency of detections, as
well as the lack of a historical process at the site that could have resulted in arsenic releases.
2) Depth of known or suspected contaminants (feet):
Contaminants at concentrations exceeding their non-residential PSRG(s) have been detected in a
sample collected from 11 to 13 feet bls. Contaminants exceeding their residential or protection
of groundwater PSRG(s) from samples collected from between 11 and 16 feet bls.
3) Area of soil disturbed by redevelopment (square feet):
Approximately 123,275 square feet.
4) Depths of soil to be excavated (feet):
Based on the existing grading plan, soil excavation beneath the southwestern portion of the
Enclave Building will be up to approximately 7 feet. Cut beneath the Overlook Building will be
limited to the approximate top 2 feet of soil. The areas of cut and fill are provided as a heat map
in Exhibit 4.
5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan):
01671-003/00322972
10
EMP Version 2, January 2021
Per the current grading plans, approximately 10,642 cubic yards of soil will be cut at the site.
6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants:
Sample data does not exist for the majority of the soils to be excavated at the site, as most of the
historical samples were collected from deeper than the proposed cut depths (S-4, 0 to 5 feet bls is
the main sample within the cut area that may be representative of soils to be excavated). The
areas of cut are not expected to be impacted based on the site history; however, Terracon will be
submitting a Work Plan under separate cover for the sampling of soils in areas of cut to properly
characterize these soils prior to their disposal (see Part 1.B below).
7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable:
Based on current grading plans, there will be a net cut of approximate 4,614 cubic yards that will
require off-site disposal. It is not anticipated that the proposed cut soils at the site are
contaminated; however, as discussed in Part 1.C below, Terracon will submit a Work Plan to
sample and characterize soils that must leave the site for disposal purposes.
Part 1.A. MANAGING ONSITE SOIL
If soil is anticipated to be excavated from the Brownfield Property, relocated on the Brownfields
Property, or otherwise disturbed during site grading or other redevelopment activities, please
provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are
acceptable, if only preliminary data available).
1) HAZARDOUS WASTE DETERMINATION:
a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous
Waste Section under 40 CFR Part 261.31‐261.35?....................................... ☐Yes ☒No
☐ If yes, explain why below, including the level of knowledge regarding processes
generating the waste (include pertinent analytical results as needed).
Click or tap here to enter text.
☐ If yes, do the soils exceed the “Contained‐Out” levels in Attachment 1 of the
North Carolina Contained‐In Policy?................................................. ☐ Yes ☐ No
b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS
THE CONTAINED‐OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA
CONTAINED‐IN POLICY THE SOIL MAY NOT BE RE‐USED ON SITE AND MUST BE
DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND
REGULATIONS.
c) Does the soil contain a CHARACTERISTIC WASTE?.................................... ☐ Yes ☒ No
☐ If yes, mark reason(s) why below (and include pertinent analytical results).
☐ Ignitability Click or tap here to enter text.
☐ Corrosivity Click or tap here to enter text.
01671-003/00322972
11
EMP Version 2, January 2021
☐ Reactivity Click or tap here to enter text.
☐ Toxicity Click or tap here to enter text.
☐ TCLP results Click or tap here to enter text.
☐ Rule of 20 results (20 times total analytical results for an individual
hazardous constituent on TCLP list cannot, by test method, exceed regulatory
TCLP standard)
Click or tap here to enter text.
☒ If no, explain rationale:
Based on the TCLP Rule of 20 results, residual contaminants identified in the soils
on the site do not exceed the TCLP limits.
d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE
SOIL MAY NOT BE RE‐USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE
WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS.
2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in
place with low permeability barrier, removed to onsite location and capped, removed offsite):
☒ Preliminary Health‐Based Residential SRGs
☐ Preliminary Health‐Based Industrial/Commercial SRGs
☒ Division of Waste Management Risk Calculator (For Brownfields Properties Only)
☐ Site‐specific risk‐based cleanup level. Please provide details of methods used for
determination/explanation.
Click or tap here to enter text.
Additional comments:
Click or tap here to enter text.
3) If known impacted soil is proposed to be reused within the Brownfields Property Boundary,
please check the measures that will be utilized to ensure safe placement and documentation of
same. Please attach a proposed location diagram/site map.
☒ Provide documentation of analytical report(s) to Brownfields Project Manager
☒ Provide documentation of final location, thickness and depth of relocated soil on site map
to Brownfields Project Manager once known
☐ Geotextile to mark depth of fill material.
Provide description of material:
Click or tap here to enter text.
☒ Manage soil under impervious cap ☒ or clean fill ☒
☒ Describe cap or fill:
Impervious caps will consist of hardscapes (asphalt and/or concrete pavement and building
01671-003/00322972
12
EMP Version 2, January 2021
footprint) or at least two feet of demonstrably non-impacted soils from other portions of
the site.
☐ Confer with NC BF Project Manager if Brownfield Plat must be revised (or re‐recorded if
actions are Post‐Recordation).
☒ GPS the location and provide site map with final location.
☐ Other. Please provide a description of the measure:
4) Please describe the following action(s) to be taken during and following excavation and
management of site soils:
Management of fugitive dust from site
☒ Yes, describe the method will include:
Soils that are dry and have the potential to migrate through air from the site will be managed
in accordance with typical construction practices, which include a periodic light application
of water via tanker truck to moisten soils and reduce airborne dust. Management of fugitive
dust for constituents of concern will not be conducted at the site beyond typical construction
practices.
☐ No, explain rationale:
Click or tap here to enter text.
Field Screening of site soil
☒ Yes, describe the field screening method, frequency of field screening, person conducting
field screening:
If during grading, impacted soils are discovered, procedures for screening and sampling the
soils will be implemented as described in the section for “Contingency for encountering
unknown tanks, drums, or other waste materials”. Visual observations of discoloration and
the detection of odors by on-site construction personnel during grading activities will
prompt notification of the on-call environmental consultant. The consultant will visit the
site and assess the questionable soils.
☐ No, explain rationale:
Soil Sample Collection
☐ Yes, describe the sampling method (e.g., in‐situ grab, composite, stockpile, etc.):
Click or tap here to enter text.
☒ No, explain rationale:
If during grading activities impacted soils are discovered, procedures for screening and
Click or tap here to enter text.
01671-003/00322972
13
EMP Version 2, January 2021
sampling the soils will be implemented as described in the section for “Contingency for
encountering unknown tanks, drums, or other waste materials.” Laboratory analysis for
such soil sampling will be determined based on the nature of the unexpected impacts and
a discussion with the Brownfields Project Manager.
If soil samples are collected for analysis, please check the applicable chemical analytes:
☒ Volatile organic compounds (VOCs) by EPA Method 8260
☒ Semi‐volatile organic compounds (SVOCs) by EPA Method 8270
☒ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium
and silver): Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ Pesticides: Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ PCBs: Specify Analytical Method Number(s):
Click or tap here to enter text.
☒ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium,
Herbicides, etc.): Specify Analytical Method Number(s):
Hexavalent chromium by EPA Method 7199.
Laboratory analysis for soil sampling will be determined based on the nature of the
unexpected impacts and a discussion with the Brownfields Project Manager at the time
the impacts are encountered.
☒ Check to confirm that stockpiling of known or suspected impacted soils will be conducted
in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion
control, prohibiting contact between surface water/precipitation and contaminated soil,
and preventing contaminated runoff. Explain any variances or provide additional details as
needed:
☒ Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or
permanent hardscape). Select chemical analyses for final grade samples with check boxes
below (Check all that apply):
☒ Volatile organic compounds (VOCs) by EPA Method 8260
☒ Semi‐volatile organic compounds (SVOCs) by EPA Method 8270
Deviations from Figure 1 will not occur during stockpiling of soils. If construction logistics (e.g. schedule,
physical site constraints, etc.) prevent proper stockpiling of soils, the contingency procedures will be to
directly load soils onto trucks for export and disposal off the site. Should this alternative be required,
the exported soils will be sampled in accordance with Brownfields requirements and the selected
disposal facility will be contacted to discuss sampling requirements (analyses, frequency). Brownfields
approval will be obtained prior to soil export from the site.
01671-003/00322972
14
EMP Version 2, January 2021
☒ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead,
selenium and silver): Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ Pesticides: Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ PCBs: Specify Analytical Method Number(s):
Click or tap here to enter text.
☒ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent
Chromium, Herbicides, etc.):
Hexavalent chromium by EPA Method 7199.
Please provide a scope of work for final grade sampling, including a diagram of soil
sampling locations, number of samples to be collected, and brief sampling methodology.
Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs
which should be taken from 1-2 ft below ground surface. Alternatively, indicate if a work
plan for final grade sampling may be submitted under separate cover.
Based on preliminary development plans for the site, it is expected that exposed soils (not
capped under structures or hardscapes) will be limited to relatively minor landscaped
areas at the site between the buildings and sidewalks.
Six composite soil samples will be collected from these areas of exposed soil, as shown on
Exhibit 7. Composite soil samples will be collected using a decontaminated hand auger
from shallow depths (0 to 2 feet) in accordance with the sampling procedures outlined in
the NCDEQ Inactive Hazardous Site Branch’s (IHSB) Guidelines for Assessment and Cleanup
of Contaminated Sites (January 2020). Each of the samples will be composited from three
or four individual locations. The soils from each location will be divided equally with one
half placed in a sealed plastic bag that is placed on ice within a cooler and the other half
placed in a sealed plastic bag that is left in the sun and allowed to volatilize for
approximately 5 to 10 minutes. After the volatilization period, the headspace of the second
plastic bag will be screened for volatile vapors using a photo-ionization detector (PID). A
grab sample for VOC analysis will be collected from the sealed plastic bag that had been
stored on ice from the location exhibiting the highest PID reading. For composite sample
collection, soils from the sealed plastic bags (placed on ice) from each set of borings will
then be composited using a decontaminated stainless-steel bowl and spoon via the sample
homogenization procedures outlined in the U.S. Environmental Protection Agency’s
SESDPROC-300-R3 (June 11, 2020) guidance.
Samples will be analyzed for VOCs (8260), SVOCs (8270), RCRA 8 Metals (6010/7471), and
hexavalent chromium (7199). In addition to the six composite samples, Terracon will also
collect the following samples for quality assurance/quality control purposes: one
01671-003/00322972
15
EMP Version 2, January 2021
field/equipment blank (collected by rinsing deionized water over the bucket of the hand
auger and the mixing bowl and collecting the rinsate in laboratory-supplied glassware;
sample to be analyzed for VOCs only), one blind duplicate sample analyzed for the full suite
of analyses, and one matrix spike/matrix spike-duplicate sample analyzed for the full suite
of analyses. A Level II QA/QC package will be requested from the laboratory, whose
reporting and method detection limits will meet applicable screening criteria to the extent
technologically feasible. The analytical report will include the use of J-flags for estimated
concentrations.
Please note that the soil sample aliquot locations shown in Exhibit 7 are subject to change
based on possible changes to the final locations of exposed landscaping post-
redevelopment and the possible location of sub-grade utilities to be installed at the site.
The NCBP Project Manager will be contacted to discuss changes to these locations if/as
needed.
☐ If final grade sampling was NOT selected, please explain rationale:
Click or tap here to enter text.
Part 1.B. IMPORTED FILL SOIL
NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL
FROM THE BROWNFIELDS PROGRAM. According to the Brownfields IR 15, “Documenting
imported soil (by sampling, analysis, and reporting in accordance with review and written
approval in advance by the Brownfields Program), will safeguard the liability protections provided
by the brownfields agreement and is in the best interest of the prospective developer/property
owner.”
Requirements for importing fill:
1) Will fill soil be imported to the site?................................................ ☐ Yes ☒ No ☐ Unknown
Based on current grading plans, the site has a net cut of approximately 4,614 cubic yards. The
proposed redevelopment will utilize cut soils from portions of the site to satisfy fill
requirements in other areas. As such, no fill soil is planned for import at this time.
2) If yes, what is the estimated volume of fill soil to be imported?
0 cubic yards.
3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range
of depths, please list the range.)
Some portions of the site will require fill up to approximately 8-feet (filling and raising grade of the
existing stormwater detention pond in the northeast portion of the site). The majority of areas to
receive fill will only require between 0 and 2 feet of fill. As discussed above, import of soils for use
of fill is not planned, as cut soils from other portions of the site will be utilized as fill material.
01671-003/00322972
16
EMP Version 2, January 2021
4) Provide the source of fill, including: location, site history, nearby environmental concerns,
etc. Attach aerial photos, maps, historic Sanborn maps and a borrow source site history:
There are no plans for import fill. If soils are proposed for import to the site in the future; a work
plan for pre-import sampling would be submitted to the Brownfields PM for approval, or such soils
will be obtained from a source which has been pre-approved by the Brownfields Program as a
suitable fill source and pre-import sampling is not necessary.
5) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide a plan to analyze fill
soil to demonstrate that it meets acceptable standards applicable to the site and can be
approved for use at the Brownfields property.
Not applicable, as import soil is not currently planned. If plans change and soils are to be imported,
attempts will be made to import them from an NCDEQ-approved source. If construction
plans/logistics dictate an alternative, non-approved fill source be selected during the project, a
work plan for pre-import sampling will be submitted to the Brownfields PM for approval that
demonstrates acceptable criteria for obtaining soils from the alternate fill source. Approval will be
obtained from the PM prior to the import of soils.
6) Please check the applicable chemical analytes for fill soil samples. (Check all that apply):
☒ Volatile organic compounds (VOCs) by EPA Method 8260
☒ Semi‐volatile organic compounds (SVOCs) by EPA Method 8270
☒ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead,
selenium and silver): Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ Pesticides: Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ PCBs: Specify Analytical Method Number(s):
Click or tap here to enter text.
☒ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent
Chromium, Herbicides, etc.):
Hexavalent chromium by EPA Method 7199.
7) The scope of work for import fill sampling may be provided below or in a Work Plan
submitted separately for DEQ review and approval. Attach specific location maps for in-situ
borrow sites. If using a quarry, provide information on the type of material to be brought
onto the Brownfields Property.
A work plan will be prepared and submitted under separate cover if it is determined that the
source of any import soils has not been pre-approved by the NCDEQ.
01671-003/00322972
17
EMP Version 2, January 2021
Part 1.C. EXPORTED SOIL
NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE
BROWNFIELDS PROGRAM. FAILURE TO OBTAIN APPROVAL MAY VIOLATE A BROWNFIELDS
AGREEMENT CAUSING A REOPENER OR JEOPARDIZING ELIGIBILITY IN THE PROGRAM,
ENDANGERING LIABILITY PROTECTIONS AND MAKING SAID ACTION POSSIBLY SUBJECT TO
ENFORCEMENT. JUSTIFICATIONS PROVIDED BELOW MUST BE APPROVED BY THE PROGRAM IN
WRITING PRIOR TO COMPLETING TRANSPORT ACTIVITIES. Please refer to Brownfields IR 15 for
additional details.
1) If export from a Brownfields Property is anticipated, please provide details regarding the
proposed export actions. Volume of exported soil, depths, location from which soil will
be excavated on site, related sampling results, etc. Provide a site map with locations of
export and sampling results included.
Based on current grading plans, approximately 4,614 cubic yards of excavated soils will require
export from the site. Existing sample data does not exist for these soils. Terracon is preparing a
Work Plan to be submitted under separate cover to adequately characterize these soils for disposal
purposes. Disposal decisions for these soils will be based on the analytical results of said sampling.
Based on site history and past sampling, it is not anticipated that the soils to be exported will be
impacted by contaminants. Soils determined to not be impacted would be disposed at a nearby
LCID landfill such as the Lakeview Road Landfill, Reeves Landfill, Old 27 Landfill, or Kelly Road
Landfill (please note that these landfills are provided as examples of possible LCID disposal facilities
and this list is not intended to limit the PD’s disposal options). Soils determined to be impacted by
contaminants would either be disposed off-site at a permitted, lined landfill (Subtitle D) such as
the CMS Republic Landfill located at 5105 Morehead Road in Concord, North Carolina) or instead
transferred to another Brownfields site with similar contaminants and contaminant
concentrations, should such a site be present nearby and willing to accept the soils and prior DEQ
approval is obtained.
Additional off-site soil disposal methods (landfarming, as beneficial fill at a non-Brownfields
property) have also been selected to provide flexibility in the event the PD wishes to change its
contingency plans.
2) To what type of facility will the export Brownfields soil be sent?
☒ Subtitle D/Municipal Solid Waste Landfill (analytical program to be determined by
landfill)
☒ Permitted but Unlined Landfill (i.e. LCID, C&D, etc.) Analytical requirements to be
determined by the accepting landfill;
☒ Landfarm or other treatment facility
☒ Use as fill at another suitable Brownfields Property – determination that a
site is suitable will require, at a minimum, that similar concentrations of the same or
similar contaminants already exist at both sites, use of impacted soil will not increase
01671-003/00322972
18
EMP Version 2, January 2021
the potential for risk to human health and the environment at the receiving Brownfields
property, and that a record of the acceptance of such soils from the property owner of
the receiving site is provided to the Brownfields Program. Please provide additional
details below.
☒ Use as Beneficial Fill off-site at a non-Brownfields Property - Please provide
documentation of approval from the property owner for receipt of fill material. This will
also require approval by the DEQ Solid Waste Section. Additional information is
provided in IR 15. Please provide additional details below.
3) Additional Details: (if transfer of soil to another property is requested above, please provide
details related to the proposed plans).
See Part 1.C Item 1 above. Following completion of in situ soil characterization, proposed soil
export disposal locations (other than CMS Republic) will be provided to the Brownfields
Program for approval before any export occurs.
Part 1.D. MANAGEMENT OF UTILITY TRENCHES
☐ Install liner between native impacted soils and base of utility trench before filling with clean fill
(Preferred)
☒ Last out, first in principle for impacted soils (if soil can safely be reused onsite and is not a
hazardous waste), i.e., impacted soils are placed back at approximately the depths they
were removed from such that impacted soil is not placed at a greater depth than the original
depth from which it was excavated.
During initial site grading activities, workers should use appropriate safety personal protective
equipment (PPE). The on-site Health and Safety Plan will address potential exposure of workers to
constituents of concern (COCs). Soils will at times be disturbed for the construction of utilities or
other structures. With respect to subsurface utility construction at the site, the general rule will be
to remove and stockpiled soils so that a “last out, first in” process occurs. During excavation, soils in
the upper 2 feet will be stockpiled and segregated as the first materials removed. These soils/fill
materials will be the last returned to the excavation during backfilling. Soils will typically “bulk” or
expand in volume when disturbed by excavation. The contractor will compact these materials into
place according to the compaction requirements of the construction design. If no specifications for
compacted fill exist, the contractor will tamp the materials in place using the mechanical excavator
or equivalent. Utilities or structures will replace a certain volume of soils in these areas, resulting in
excess soils as excavation spoils. After the initial grading of the site, the worker and contractor
should plan from onset of construction to maintain a cap comprised of either (a) clean fill, or (b)
other barrier approved by the NCDEQ for areas that will not be capped with a building, asphalt, or
concrete surface. If excess contaminant impacted soils/fill are produced from excavation as spoils
which cannot be restored to original depths through the process of “first out, last in”, they must be
handled with special care. The worker or contractor will work with the Brownfields Project Manager
to ensure that, if the soils are contaminated, they are either properly re-used on the site or disposed
at an off-site location.
01671-003/00322972
19
EMP Version 2, January 2021
☒ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport,
and/or degradation of conduit materials due to direct impact with contaminants?
☐ If yes, provide specifications on barrier materials or provide the results of this evaluation in the
Vapor Mitigation Plan. Note that if vapor mitigation is planned for site buildings, utility
corridors will need to be evaluated as part of mitigation designs:
Click or tap here to enter text.
☒ If no, include rationale here:
Soil vapor data at the site indicates that vapor mitigation measures are not necessary at the site.
Summaries of the NCDEQ Risk Calculator model results, which do not indicate unacceptable risk
associated with vapor intrusion from soil vapor concentrations obtained in both 2020 and 2021,
are included as attachments to the EMP.
☐ Unknown, details to be provided in the Vapor Mitigation Plan for the site.
Click or tap here to enter text.
Other comments regarding managing impacted soil in utility trenches:
Concerns and methods for handling impacted soils do not preclude or modify any of the
Occupational Safety and Health Administration (OSHA) requirements for worker safety
incumbent upon contractors for regular site safety and trenching/excavation activities. OSHA
requirements will dictate adjustments of the soil management methods, where necessary.
PART 2. GROUNDWATER
1) What is the depth to groundwater at the Brownfields Property?
Depth to groundwater has been ranging from approximately 17 to 25 feet bls at the site.
2) Is groundwater known to be contaminated by ☐onsite ☒offsite ☐both or ☐unknown
sources? Describe source(s):
Existing data indicate various petroleum constituents, including benzene, toluene, ethylbenzene,
and xylene (BTEX) have been identified above their 2L Standards at the site. Refer to attached
Table 2 for specific concentrations.
These compounds are due to the release (NCDEQ LUST Incident 15378) from the UST system
formerly located on the adjacent property to the northwest of the site.
3) What is the direction of groundwater flow at the Brownfields Property?
Based on surficial topography, the direction of shallow groundwater flow is inferred to be toward
the east.
4) Will groundwater likely be encountered during planned redevelopment activities?
☒Yes ☐No
If yes, describe these activities:
01671-003/00322972
20
EMP Version 2, January 2021
Based on the proposed development plans, grading activities at the site are not anticipated to
exceed a depth of approximately 8 feet bls; as such, groundwater will likely not be encountered
during the majority of the soil work that will occur will not encountered groundwater. However,
the Overlook building will require the installation of deep foundations that will be installed into
bedrock, which averages approximately 31 feet bls. The installation of the foundations will be
achieved by drilling large diameter boreholes (ranging from approximately 3 to 6.5 feet) to the
necessary depth, installing concrete caissons within the boreholes, and then installing the deep
foundations inside the caissons. As these boreholes intersect the water table, it is anticipated
that some temporary dewatering will be necessary. The boreholes typically are open for
approximately one day prior to installation of the caissons. Based on the anticipated extent of
the interaction with groundwater during construction activities (e.g. during installation of
foundational caissons only), construction activities are not expected to modify existing
groundwater flow in a manner that would have an effect on adjacent properties or increase vapor
intrusion risk at the property.
Regardless of the answer; in the event that contaminated groundwater is encountered
during redevelopment activities (even if no is checked above), list activities for contingent
management of groundwater (e.g., dewatering of groundwater from excavations or
foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or
sampling procedures).
Generally speaking, excavations in areas where groundwater is encountered will be allowed
to re-infiltrate for approximately 24 hours, if it does not affect the construction schedule. If
the groundwater must be removed so that construction activities may proceed, the
groundwater will be discharged to a tanker or aboveground storage containers pending
approval by the Brownfields Program, and laboratory analysis for disposal. Copies of
laboratory data and disposal manifests will also be provided to the Brownfields Program.
In the case of the temporary dewatering that will likely be necessary during foundation
installation, the PD is currently evaluating its options. Such options may include off-site
disposal, temporary containerization coupled with on-site treatment (e.g. use of a granular
activated carbon filtration) prior to discharge in accordance with the site’s construction
stormwater permit, or discharge to the municipal POTW (if granted permission by the
municipality), etc. Please note that the above procedures are given as possible examples and
are not intended to limit the PD in its selection of the ultimate groundwater management
protocol(s). Once a groundwater management option that complies with all applicable laws
has been selected, the Brownfields Program will be contacted for approval.
5) Are monitoring wells currently present on the Brownfields Property?.................☐Yes ☒No
If yes, are any monitoring wells routinely monitored through DEQ or other
agencies?..................................................................................................................☐Yes ☐No
6) Please check methods to be utilized in the management of known and previously
unidentified wells.
☒ Abandonment of site monitoring wells in accordance with all applicable regulations. It
is the Brownfields Program’s intent to allow proper abandonment of well(s) as
specified in the Brownfields Agreement, except if required for active monitoring
through another section of DEQ or the EPA.
01671-003/00322972
21
EMP Version 2, January 2021
☐ Location of existing monitoring wells marked
☐ Existing monitoring wells protected from disturbance
☒ Newly identified monitoring wells will be marked and protected from further
disturbance until notification to DEQ Brownfields can be made and approval for
abandonment is given.
7) Please provide additional details as needed:
Please note, disturbance of existing site monitoring wells without approval by DEQ is not
permissible. If monitoring wells are damaged and/or destroyed, DEQ may require that the PD
be responsible for replacement of the well.
PART 3. SURFACE WATER
1) Is surface water present at the property? ☐ Yes ☒ No ☐ Unknown
2) Attach a map showing the location of surface water at the Brownfields Property.
3) Is surface water at the property known to be contaminated? ☐ Yes ☒ No
4) Will workers or the public be in contact with surface water during planned redevelopment
activities? ☐ Yes ☒ No
Stormwater can potentially accumulate in excavations and utility trenches during construction
activities following precipitation events. In the event stormwater management is required, the
applicable excavation activities should cease pending infiltration of the water or removal and
characterization of the water.
5) In the event that contaminated surface water is encountered during redevelopment
activities, or clean surface water enters open excavations, list activities for management of
such events (e.g. flooding, contaminated surface water run‐off, stormwater impacts):
Water is not anticipated to discharge into open excavations. Excavations and trenches shall be
graded, bermed, or provided with an equivalent barrier where necessary to help prevent surface
water and/or stormwater from entering excavations and/or leaving the site boundaries.
Stormwater or water from an unidentified source that collects in excavation areas will be allowed
to infiltrate naturally if construction schedule allows or removed so that construction activities
may proceed. The water will be containerized or diverted to an on-site stormwater management
basin where the water will be sampled for disposal characterization before it is allowed to leave
the site. Based on the types of contaminants documented on the site, water samples will be
analyzed for VOCs, SVOCs and RCRA metals. If containerized water is determined to be above
regulatory standards, the Brownfields Project Manager will be contacted, and the water will be
disposed in accordance with regulatory requirements.
Any identified monitoring wells will be abandoned in accordance with the applicable regulations,
following approval from NCDEQ.
01671-003/00322972
22
EMP Version 2, January 2021
PART 4. SEDIMENT
1) Are sediment sources present on the property? ☐ Yes ☒ No
2) If yes, is sediment at the property known to be contaminated: ☐ Yes ☒ No ☐ Unknown
3) Will workers or the public be in contact with sediment during planned redevelopment
activities? ☐ Yes ☒ No
4) Attach a map showing location of known contaminated sediment at the property.
5) In the event that contaminated sediment is encountered during redevelopment activities, list
activities for management of such events (stream bed disturbance):
Not applicable. There are no known current or historical natural drainage features on the site.
PART 5. SOIL VAPOR
1) Do concentrations of volatile organic compounds at the Brownfields property exceed the
following vapor intrusion screening levels (current version) in the following media:
IHSB Residential Screening Levels:
Soil Vapor: ………..☒ Yes ☐ No ☐ Unknown
Groundwater: .….☒ Yes ☐ No ☐ Unknown
IHSB Industrial/Commercial Screening Levels:
Soil Vapor: ………..☐ Yes ☒ No ☐ Unknown
Groundwater: …..☒ Yes ☐ No ☐ Unknown
2) Attach a map showing the locations of soil vapor contaminants that exceed site
screening levels.
3) If applicable, at what depth(s) is soil vapor known to be contaminated?
In 2020, five soil vapor points were installed within the footprint of the planned building at depths
ranging from approximately 3 to 5.25 feet bls. While numerous VOCs were detected, the sole
compound exceeding its residential Soil Gas Screening Level (SGSL) was chloroform (at a concentration
of 8.37 µg/m3 vs. its residential SGSL of 8.1 µg/m3).
Five additional soil vapor points were installed and sampled at the site in 2021 to confirm the prior
results. The 2021 soil vapor points were installed to depths ranging from 5.25 feet to 8 feet bls. VOC
concentrations were not identified above their residential SGSLs.
Refer to the attached Tables 5 and 6 for specific soil vapor concentrations. Copies of modeled vapor
intrusion risk results using the NCDEQ Risk Calculator for both the 2020 and 2021 sample data sets are
also included behind the tables in the appendices. The NCDEQ Risk Calculator indicates there is not
unacceptable risk to future residential site occupants from the identified soil vapor VOC
concentrations.
01671-003/00322972
23
EMP Version 2, January 2021
4) Will workers encounter contaminated soil vapor during planned redevelopment activities?
☐ Yes ☒ No ☐ Unknown In the event that contaminated soil vapor is encountered during
redevelopment activities (trenches, manways, basements or other subsurface work,) list
activities for management of such contact:
Volatile organic compounds (VOCs) have been identified in localized areas (building footprint)
within soil vapor and groundwater. The concentrations of VOCs detected within soil vapor were
below residential SGSLs with the exception of chloroform in one sample, at a level only slightly in
excess of its SGSL. Based on the identified levels, it is not anticipated that construction workers
will encounter contaminated soil vapor during redevelopment activities. However, during
construction, site workers will be informed of the possible presence of contaminated soil vapors
particularly in trenches and other excavations on the site. If during construction, workers identify
evidence of elevated vapor concentrations (odor, lightheadedness, etc.), work will be stopped
until Terracon can mobilize to the site to complete vapor screening activities. Work will not begin
again until the vapor field screening indicates concentrations have returned to background levels.
PART 6. SUB‐SLAB SOIL VAPOR
1) Do concentrations of volatile organic compounds at the Brownfields property exceed the
following vapor intrusion screening levels (current version) in sub-slab soil vapor:
IHSB Residential Screening Levels:
Soil Vapor:………..☐ Yes ☐ No ☒ Unknown
Groundwater:.….☐ Yes ☐ No ☒ Unknown
IHSB Industrial/Commercial Screening Levels:
Soil Vapor:………..☐ Yes ☐ No ☒ Unknown
2) Groundwater:…..☐ Yes ☐ No ☒ Unknown If data indicate that sub‐slab soil vapor
concentrations exceed screening levels, attach a map showing the location of these exceedances.
3) At what depth(s) is sub‐slab soil vapor known to be contaminated? ☐0‐6 inches ☐Other, please
describe:
There are no structures currently located on the site; as such, sub-slab soil vapor samples have not
been collected.
4) Will workers encounter contaminated sub‐slab soil vapor during planned redevelopment
activities? ☐ Yes ☐ No ☒ Unknown
☒ If no, include rationale here:
There are no structures currently located on the site.
5) In the event that contaminated soil vapor is encountered during redevelopment activities, list
activities for management of such contact
Volatile organic compounds (VOCs) have been identified in localized areas within soil vapor and
groundwater beneath the site. Vapors will be evaluated, as discussed in Part 5.
01671-003/00322972
24
EMP Version 2, January 2021
PART 7. INDOOR AIR
1) Are indoor air data available for the Brownfields Property? ☐ Yes ☒ No ☐ Unknown
2) Attach a map showing the location(s) where indoor air contaminants exceed site screening levels.
3) If the structures where indoor air has been documented to exceed risk‐based screening levels will
not be demolished as part of redevelopment activities, will workers encounter contaminated
indoor air during planned redevelopment activities? ☐ Yes ☒ No ☐ Unknown
☒ If no, include rationale here:
Not applicable.
4) In the event that contaminated indoor air is encountered during redevelopment activities, list
activities for management of such contact:
VAPOR INTRUSION MITIGATION SYSTEM
Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property?
☐ Yes ☒ No ☐ Unknown
☒ If no or unknown, include rationale here as well as plans for pre-occupancy sampling, as
necessary:
Based on the 2020 and 2021 soil vapor sampling, concentrations of VOCs have not been
identified at levels that pose unacceptable risk to future residential occupants (see attached
NCDEQ Risk Calculator summaries).
DEQ’s determination is based on site conditions observed prior to redevelopment. While a
source of petroleum contamination is located on the property adjacent to the Brownfields
Property, based on the anticipated extent of the interaction with groundwater during
construction activities (e.g. during installation of foundational caissons only), construction
activities are not expected to modify existing groundwater flow in a manner that would have
an effect on adjacent properties or increase vapor intrusion risk at the property.
If yes, ☐ VIMS Plan Attached or ☐ VIMS Plan to be submitted separately
If submitted separately provide date:
VIMS Plan shall be signed and sealed by a NC Professional Engineer
If no, please provide a brief rationale as to why no vapor mitigation plan is warranted:
See above
Note that approval of this EMP does not imply approval with any vapor intrusion mitigation land
use restrictions or requirements of the recorded or draft Brownfields Agreement and that
separate approval of mitigation measures will be required.
Not applicable.
01671-003/00322972
25
EMP Version 2, January 2021
CONTINGENCY PLAN – encountering unknown tanks, drums, or other waste materials
In this section please provide actions that will be taken to identify or manage unknown
potential new sources of contamination. During redevelopment activities, it is not uncommon
that unknown tanks, drums, fuel lines, landfills, or other waste materials are encountered.
Notification to DEQ Brownfields Project Manager, UST Section, Fire Department, and/or other
officials, as necessary and appropriate, is required when new potential source(s) of
contamination are discovered. These Notification Requirements were outlined on Page 1 of this
EMP.
Should potentially impacted materials be identified that are inconsistent with known site impacts,
the Brownfields Project Manager will be notified, and a sampling plan will be prepared based on the
EMP requirements and site-specific factors. Samples will generally be collected to document the
location of the potential impacts.
Should potentially impacted materials be identified that are inconsistent with known site
impacts, the DEQ Brownfields Project Manager will be notified and a sampling plan will be
prepared based on the EMP requirements and site-specific factors. Samples will generally be
collected to document the location of the potential impacts.
Check the following chemical analysis that are to be conducted on newly identified releases:
☒ Volatile organic compounds (VOCs) by EPA Method 8260
☒ Semi‐volatile organic compounds (SVOCs) by EPA Method 8270
☒ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and
silver)
Click or tap here to enter text.
☐ Pesticides: Specify Analytical Method Number(s):
Click or tap here to enter text.
☐ PCBs: Specify Analytical Method Number(s):
Click or tap here to enter text.
☒ Other Constituents & Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.)
Please note, if field observations indicate the need for additional analyses, they should
be conducted, even if not listed here.
Hexavalent chromium by EPA Method 7199.
Please provide details on the proposed methods of managing the following commonly
encountered issues during redevelopment of Brownfields Properties.
There is a possibility that materials of unknown type (tanks, drums or impacted soils) could be
present on the site. The worker and contractor will be able to recognize when conditions change at
the site. Field staff will be able to determine if a new discovery of changed chemical conditions has
occurred, and if so, if it is significant. If there is question of the significance of a new discovery or
01671-003/00322972
26
EMP Version 2, January 2021
changed condition, the environmental manager (Terracon) or equivalent qualified environmental
professional should make the determination. The worker or contractor will be alert during
earthwork for the following indications that will trigger the possible identification of a new condition
not addressed by previous investigations and evaluation. All work will be completed in accordance
with applicable regulatory requirements.
Prior to beginning site work, the environmental manager will attend a pre-construction kick-off
meeting with the PD and the redevelopment contractors to discuss the DEQ-approved EMP and
various scenarios when it would be appropriate and necessary to notify the environmental manager
of the discovery of unknown subsurface features or potentially impacted media at the site.
Underground Storage Tanks:
Prior assessment reports have not identified suspected underground storage tanks (USTs) remaining
at the site. The worker and contractor will be cognizant of man-made containers or remnants of
containers of any material. The presence of whole or crushed drums or containers in excess of one
gallon in the soils in combination with odor or unique color changes may be indicative of a changed
condition. Should USTs, drums, or similar items be encountered during redevelopment activities, the
environmental manager (Will Frazier) will be contacted immediately, and the identified item should
remain as encountered. The NCBP Project Manager will be notified by the environmental manager
for the site within 48 hours of discovery. Following notification of the Brownfields Project Manager,
the UST or other containers will be removed from the ground after potential combustible vapors
have been stabilized. Residual fluids, if present, will be removed and sampled for VOCs, SVOCs, and
RCRA 8 metals. The fluids will be transported off-site for disposal at a suitable facility based on the
laboratory analytical results. The UST or other containers will be hauled to an off-site facility for
proper disposal and soil samples will be collected from the location of the UST or other containers
and analyzed for VOCs (EPA Method 8260B), SVOCs (EPA Method 8270D) and RCRA metals (EPA
Methods 6010D and 7471B), in accordance with the applicable DEQ UST Guidance and Brownfields
Program protocols. Impacted soil, if encountered, will be managed in accordance with the
“Managing On-site Soil” section of the EMP, as outlined above.
Documentation of the UST/container removal activities, UST disposal, and sampling results will be
provided to the Brownfields Project Manager upon receipt by the environmental manager.
Sub-Grade Feature/Pit:
If during redevelopment activities, an unknown sub-grade feature/pit is encountered, the
environmental manager (Will Frazier) will be notified immediately. The feature will be removed if
possible and the environmental manager will supervise exploratory excavation near the feature and
soils will be screened for potential impacts. If potential impacts are identified, the Brownfields
Project Manager will be notified, and soil samples will be collected from the area of potential impacts
and analyzed for VOCs (EPA Method 8260B), SVOCs (EPA Method 8270D) and RCRA metals (EPA
Methods 6010D and 7471B). The sample frequency will be determined based on the nature of the
feature and will be discussed with the Brownfields Project Manager prior to the collection of the
samples. If left in place, the location of the feature will be recorded for future reference. Soil
sampling results will be provided to the Brownfields Project Manager. If water is encountered within
a sub-grade pit, the procedures outlined in Part 3 will be followed. If a sub-grade feature or pit is
encountered and does not require removal for environmental, geotechnical, or construction
01671-003/00322972
27
EMP Version 2, January 2021
purposes, it will be filled with soil or suitable fill and construction will proceed.
Buried Waste Material – Note that if buried waste, non-native fill, or any obviously filled materials
is encountered, the DEQ Brownfields Program must be notified to determine if investigation of
landfill gases is required:
The below described protocols apply only to debris encountered during construction. If removal of
the debris is not necessary for construction or geotechnical reasons, the below protocols will not
apply.
If during redevelopment activities, buried waste materials are encountered, the environmental
manager (Will Frazier) will be notified immediately, and the identified waste should remain as
encountered. The Brownfields Project Manager will be notified by the environmental manager
within 24 hours of the environmental manager being notified. Following notification of the
Brownfields Project Manager, the environmental manager will supervise exploratory excavation
activities near the waste and soils will be screened for potential impacts. The waste will be
segregated from surrounding soils, inventoried and evaluated for proper management. If potential
impacts are identified, the Brownfields Project Manager will be notified, and soil samples will be
collected from the area of potential impacts and analyzed for VOCs (EPA Method 8260B), SVOCs
(EPA Method 8270D) and RCRA metals (EPA Methods 6010D and 7471B). The sample frequency will
be determined based on the nature of the debris and will be discussed with the Brownfields Project
Manager prior to the collection of the samples, and a determination will be made regarding the need
for an investigation of landfill gases. Additional laboratory analyses may be required based on the
types of waste discovered. The location of the debris will be recorded for future reference.
Documentation of the waste management activities and sampling results will be provided to the
Brownfields Project Manager upon receipt by the environmental manager.
If construction debris is identified during site grading, Terracon will evaluate whether the debris is
likely to be environmentally deleterious. If the debris appears to consist solely of former building
materials (e.g. concrete, wood, etc.), with Brownfields Program approval, the debris will be disposed
at an off-site C&D landfill. If the debris appears to consist of impacted materials, a sampling and
disposal protocol will be determined in coordination with the Brownfields Program. Areas of
suspected contaminated soil that remain at the site after excavation is complete above the NCDEQ
Residential PSRG will be managed pursuant to this plan.
Re-Use of Impacted Soils On-Site:
See Part 1 – Soil and Part 1.A for details regarding the re-use of impacted soils on the site.
If unknown, impacted soil is identified on-site, management on-site can be considered after the
project team provides the necessary information, outlined in Part 1.A. Item 11, for Brownfields
Project Manager approval prior to final placement on-site.
If other potential contingency plans are pertinent, please provide other details or scenarios as
needed below:
If impacted soils are noted at the site, the suspected soils will be isolated as soon as possible from
contact and disturbance from rain and wind until screening identification can be conducted.
Construction flagging tape attached to stakes can be used to prevent accidental movement of the
soils by earthwork operations. Covering of the soils with plastic sheeting anchored by planks,
01671-003/00322972
28
EMP Version 2, January 2021
sandbags, or an equivalent material will occur. The soils will be screened for volatile and semi-
volatile organic compounds and RCRA metals. The screening will be conducted by the on-site
environmental manager or other qualified environmental professional. The owner or contractor
may alternatively go directly to laboratory testing for identification purposes.
Screening activities can be conducted on the site and can produce preliminary results quickly. The
field tests do not produce a precise measurement of the amounts of contaminants found in the
soils but indicates whether contaminants are likely present and will generally warrant further
caution and actual measurement. If preliminary screening activities indicate a changed condition
may be present, it may be necessary to conduct laboratory testing to determine if contaminants
are present in the soil and actually pose a significant risk. Laboratory testing requires time that
varies depending on the type of test needed. In general, laboratory testing for VOCs, SVOCs and
metals can be completed in approximately 5 to 7 business days unless special arrangements are
made with the laboratory for more expensive “RUSH” results. During this time, the suspected
impacted soils should be further isolated from worker and public exposure. Special handling and
care must be taken in sampling and transporting soils for the laboratory tests to be accurate. The
workers in physical contact with suspected impacted soils should have training consistent with 29
OSHA 1910.120.
For small volumes, the soils may be placed temporarily in steel open-top drums with bolt-on lids.
After sealing, the drum should be clearly labeled with pertinent information such as “Do Not
Disturb”, sample number, date, and name of sampler. The drums should be placed in an on-site
area protected from general traffic. For larger volumes, it may be effective to place the soils into
commercial roll-off dumpsters which have been previously washed and cleaned of residues or soils
can be stockpiled on plastic sheeting. The containers will not have free-draining bottoms and
stockpiles shall be graded, bermed, or provided with an equivalent barrier where necessary to help
prevent water run-off, in accordance with Figure 1. The tops of the containers or stockpiles will
then be covered with plastic sheeting and secured against wind and rain. The commercial
containers or stockpiles should be placarded with information similar to the notation on drums.
POST‐REDEVELOPMENT REPORTING
☒ Check this box to acknowledge that a Redevelopment Summary Report will be required for the
project. If the project duration is longer than one year, an annual update is required and will be
due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of
this EMP (as agreed upon with the Project Manager). These reports will be required for as long as
physical redevelopment of the Brownfields Property continues, except that the final
Redevelopment Summary Report will be submitted within 90 days after completion of
redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary
Report is anticipated to be submitted on 1/31/2023
The Redevelopment Summary Report shall include environment-related activities since the last
report, with a summary and drawings, that describes:
1. actions taken on the Brownfields Property;
01671-003/00322972
29
EMP Version 2, January 2021
2. soil grading and cut and fill actions;
3. methodology(ies) employed for field screening, sampling and laboratory analysis of
environmental media;
4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and
ultimate disposition of any soil, groundwater or other materials suspected or confirmed
to be contaminated with regulated substances; and
5. removal of any contaminated soil, water or other contaminated materials (for example,
concrete, demolition debris) from the Brownfields Property (copies of all legally required
manifests shall be included).
☒ Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment
Summary Report in compliance with the site’s Brownfields Agreement.
01671-003/00322972
31
EMP Version 2, January 2021
APPROXIMATE
SITE BOUNDARY
TOPOGRAPHIC MAP
Red Carpet Inn Brownfields Site(AKA Morehead Overlook)NCBP #23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina
TOPOGRAPHIC MAP IMAGE COURTESY OF THE U.S. GEOLOGICAL SURVEY QUADRANGLES INCLUDE: CHARLOTTE EAST, NC (1/1/1988).
2701 Westport Road
Charlotte, NC 28208-3608
71197661 Project Manager:
Drawn by:
Checked by:
Approved by:
WOF
MNM
MNM
1”=2,000’
71197661.1
Mar. 2021
Project No.
Scale:
File Name:
Date: 2
WOF Exhibit
B
C
B
C
B
EXISTING 5
LEVEL OFFICE
BUILDING
EUCLID AVEEAST MOREHEAD STREETEXISTING DUKE ENERGY SUBSTATIONNEW PRIVATE DRIVE150' LONG FIRE ACCESS
EXISTING 1 LEVEL PARKING STRUCTURE
26' SETBACK ALONG
MOREHEAD
PROPERTY LINE
16' SETBACK ALONG EUCLID
GROUND LEVELS MF BASEMENT
MAIN LOBBY
RETAIL
RETAIL
TRASH
MOVE-IN
GENERATOR TRASH
RISER
FCC
TELE/DATA
POE
ELECTRICAL
RESIDENTIAL
RESIDENTIAL
PLAZA /
FORECOURT
SERVICE
R
AMENITY
RESIDENTIAL
PARKING ENTRANCE /
EXIT AT PRIVATE DRIVE
SPEED RAMP UP
TO TYPICAL
PARKING LEVELS
ENCLAVE UTILITY YARD
MAIL
T T T T
OVERLOOK UTILITY YARD
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 6:01:35 PM C:\Users\jgraham\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_jgraham@bbm-arch.com.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
ARCHITECTURAL SITE
PLAN
20SPN100
08.03.2021
JG/KW
CHARLOTTE, NC
A0.01SCALE: 3/64" = 1'-0"A0.01
1 OVERALL SITE PLAN
Revisions
No. Description DateExhibit 4 – Grading MapRed Carpet Inn Brownfields SiteAKA Morehead OverlookNCBP #23070-19-060615 East Morehead StreetCharlotte, North CarolinaExhibit 4 – Grading MapRed Carpet Inn Brownfields SiteAKA Morehead OverlookNCBP #23070-19-060615 East Morehead StreetCharlotte, North Carolina
1. COLORS ARE DIAGRAMATIC AND DO NOT REFLECT
FINAL MATERIAL SELECTIONS. ALL FINAL SELECTIONS
TO BE APPROVED BY OWNER AND ARCHITECT.
2. ALLOWED OPENINGS ARE UNLIMITED ON ALL
ELEVATIONS EXCEPT THE NORTH. PROXIMITY OF THE
NORTH ELEVATION TO THE PEROPERTY LINE LIMITS THE
OPENINGS AT ANY NON-PARKING LEVEL TO 45%
(NCBC T705.8)
3. WINDOW TRIM TO MATCH COLOR OF
SURROUNDING FINISH UNLESS NOTED OTHERWISE.
4. BRICK CONTROL JOINES ARE TO BE FREE OF MORTAR
AND PROVIDED WITH BACKER ROD AND SEALANT.
5. AT ALL RECESSES IN THE BUILDING FACADE, EXTERIOR
MATERIAL IS TO BE CONTINUED TO THE INSIDE
CORNER UNLESS NOTED OTHERWISE.
GENERAL NOTES
MATERIAL KEY NOTES
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
BRK-1:
STANDARD MASONRY VENEER, RUNNING
BOND.
COLOR: TBD
BRK-2:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD
BRK-3:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD, ACCENT
EIFS-1:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
EIFS-2:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
FC-1:
FIBER CEMENT PANEL RAINSCREEN SYSTEM WITH
APPLIED TRIM
COLOR: TBD
MTL SCREEN:
DECORATIVE METAL SCREENING SYSTEM WITH
REQUIRED STRUCTURAL FRAMING AND SUPPORT.
ALTERNATE TO INCLUDE FABRIC SYSTEM IN LIEU OF
METAL SCREEN
LEVEL 1-H
EL 713' -6"
LEVEL 3
EL 733' -6"
LEVEL 2
EL 722' -10"
LEVEL 1-M
EL 711' -6"
LEVEL 4
EL 744' -2"
LEVEL 5
EL 754' -10"
LEVEL 6
EL 765' -6"
LEVEL 7
EL 776' -2"
LEVEL 8
EL 786' -10"
LEVEL 9
EL 797' -6"
LEVEL 10
EL 808' -2"
LEVEL 6.5
EL 770' -10"
LEVEL 11
EL 818' -10"
LEVEL 12
EL 832' -10"
LEVEL 13
EL 844' -10"
LEVEL 14
EL 855' -6"
LEVEL 15
EL 866' -2"
LEVEL 16
EL 876' -10"
LEVEL 17
EL 887' -6"
LEVEL 18
EL 898' -2"
LEVEL 19
EL 908' -10"
LEVEL 20
EL 919' -6"
LEVEL 21
EL 930' -2"
LEVEL 22
EL 940' -10"
LEVEL 23
EL 951' -6"
LEVEL 25
EL 974' -2"
TOWER ROOF
EL 998' -2"
LEVEL 26
EL 986' -2"
LEVEL 24
EL 962' -2"
DW ROOF BRG
EL 785' -6"
EIFS-1
EIFS-1
FC-1
BRK-2
EIFS-2
ROOF FEATURE
EL 1010' -2"
BRK-3
GUARD-HEIGHT PREFINISHED ALUMINUM RAILING
SYSTEM WITH HORIZONTAL BARS
60"+ GLASS GUARDRAIL SYSTEM
AT AMENITY DECK
ANODIZED STOREFRONT WINDOW SYSTEM W/
INTEGRAL MULLION CAPS
HANGER-SUPPORTED CANOPY WITH
BRACKETS AND METAL PROFILE
ANODIZED ALUMINUM STOREFRONT
SYSTEM W/ VISION GLAZING
ANODIZED ALUMINUM
CURTAINWALL SYSTEM
PROJECTED ROOF FEATURE
WITH ACM PROFILE AND SOFFIT
OVERBUILT FRAMING
WITH EIFS FINISH
ANODIZED ALUMINUM WINDOW WALL
SYSTEM W/ INTEGRAL MULLION CAPS
METAL PANEL COVER INTEGRAL WITH
WINDOW SYSTEM AT SLAB EDGES
PROVIDE EIFS OVER LIGHT-GAUGE FRAMING
AT RAISED WINDOW UNITS, TYP.
PREFINISHED ALUMINUM COPING, TYP. AT PARAPET
COPING CONDITIONS
OVERBUILT FIBER-CEMENT WRAPPED
CORNICE PROFILE
VEHICULAR CABLE CRASH BARRIER, TYP.
SITE WALLS TO BE MASONRY VENEER
WITH CAST STONE CAP, TYP.
VINYL WINDOW ASSEMBLY WITH DOUBLE-HUNG
AND FIXED UNITS. TYP ASSEMBLY IS 8'W X 6'H
ANODIZED ALUMINUM CURTAINWALL
SYSTEM WITH DECORATIVE GLAZING
MULTIFAMILY ENTRANCE
AT MOREHEAD
RETAIL ENTRANCEPROVIDE TUBE STEEL TO SUPPORT
UPPER WINDOW UNITS
PROVIDE SOLDIER COURSE AT WINDOW
HEADS AND ROWLOCK SILLS, TYP.
PROVIDE GRANITE
WATER TABLE AT PIERS
MODULAR BRICK VENEER W/
ACCENT DETAILING AT OPENINGS
AND HORIZONTAL BANDS
METAL SCREENING AT PARKING DECK
RETAIL ENTRANCE
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 4:29:11 PM C:\Users\kwarren\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_kwarrenLJ2JT.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
BUILDING ELEVATIONS
20SPN100
08.03.2021
JG/AW/KW
CHARLOTTE, NC
A4.01
Revisions
No. Description Date
SCALE: 1/16" = 1'-0"A4.01
1 MOREHEAD ST. ELEVATION -
1. COLORS ARE DIAGRAMATIC AND DO NOT REFLECT
FINAL MATERIAL SELECTIONS. ALL FINAL SELECTIONS
TO BE APPROVED BY OWNER AND ARCHITECT.
2. ALLOWED OPENINGS ARE UNLIMITED ON ALL
ELEVATIONS EXCEPT THE NORTH. PROXIMITY OF THE
NORTH ELEVATION TO THE PEROPERTY LINE LIMITS THE
OPENINGS AT ANY NON-PARKING LEVEL TO 45%
(NCBC T705.8)
3. WINDOW TRIM TO MATCH COLOR OF
SURROUNDING FINISH UNLESS NOTED OTHERWISE.
4. BRICK CONTROL JOINES ARE TO BE FREE OF MORTAR
AND PROVIDED WITH BACKER ROD AND SEALANT.
5. AT ALL RECESSES IN THE BUILDING FACADE, EXTERIOR
MATERIAL IS TO BE CONTINUED TO THE INSIDE
CORNER UNLESS NOTED OTHERWISE.
GENERAL NOTES
MATERIAL KEY NOTES
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
BRK-1:
STANDARD MASONRY VENEER, RUNNING
BOND.
COLOR: TBD
BRK-2:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD
BRK-3:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD, ACCENT
EIFS-1:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
EIFS-2:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
FC-1:
FIBER CEMENT PANEL RAINSCREEN SYSTEM WITH
APPLIED TRIM
COLOR: TBD
MTL SCREEN:
DECORATIVE METAL SCREENING SYSTEM WITH
REQUIRED STRUCTURAL FRAMING AND SUPPORT.
ALTERNATE TO INCLUDE FABRIC SYSTEM IN LIEU OF
METAL SCREEN
LEVEL 1-H
EL 713' -6"
LEVEL 3
EL 733' -6"
LEVEL 2
EL 722' -10"
LEVEL 1-M
EL 711' -6"
LEVEL 4
EL 744' -2"
LEVEL 5
EL 754' -10"
LEVEL 6
EL 765' -6"
LEVEL 7
EL 776' -2"
LEVEL 8
EL 786' -10"
LEVEL 9
EL 797' -6"
LEVEL 10
EL 808' -2"
LEVEL 11
EL 818' -10"
LEVEL 12
EL 832' -10"
LEVEL 13
EL 844' -10"
LEVEL 14
EL 855' -6"
LEVEL 15
EL 866' -2"
LEVEL 16
EL 876' -10"
LEVEL 17
EL 887' -6"
LEVEL 18
EL 898' -2"
LEVEL 19
EL 908' -10"
LEVEL 20
EL 919' -6"
LEVEL 21
EL 930' -2"
LEVEL 22
EL 940' -10"
LEVEL 23
EL 951' -6"
LEVEL 25
EL 974' -2"
TOWER ROOF
EL 998' -2"
LEVEL 26
EL 986' -2"12' - 0"12' - 0"12' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"12' - 0"14' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"9' - 4"2' - 0"286' - 8"LEVEL 24
EL 962' -2"
DW ROOF BRG
EL 785' -6"
ROOF FEATURE
EL 1010' -2"
EIFS-2
EIFS-2EIFS-1
FC-1
BRK-1
BRK-2
METAL SCREENING AT PARKING DECK
SITE WALLS TO BE MASONRY VENEER
WITH CAST STONE CAP, TYP.
ANODIZED ALUMINUM CURTAINWALL
SYSTEM WITH APPLIED DECORATIVE SCREEN
MULTIFAMILY ENTRANCE
AT EUCLID
ANODIZED ALUMINUM
STOREFRONT SYSTEM
W/ VISION GLAZING
OVERBUILT FIBER-CEMENT WRAPPED
CORNICE PROFILE
VINYL WINDOW ASSEMBLY WITH DOUBLE-HUNG
AND FIXED UNITS. TYP ASSEMBLY IS 8'W X 6'H
PROVIDE SOLDIER COURSE AT WINDOW
HEADS AND ROWLOCK SILLS, TYP.
GUARD-HEIGHT PREFINISHED ALUMINUM
RAILING SYSTEM WITH HORIZONTAL BARS
ANODIZED STOREFRONT WINDOW
SYSTEM W/ INTEGRAL MULLION CAPS
PREFINISHED ALUMINUM COPING, TYP. AT
PARAPET COPING CONDITIONS
ANODIZED ALUMINUM WINDOW WALL
SYSTEM W/ INTEGRAL MULLION CAPS
METAL PANEL COVER INTEGRAL WITH
WINDOW SYSTEM AT SLAB EDGES
PROVIDE EIFS OVER LIGHT-GAUGE FRAMING
AT RAISED WINDOW UNITS, TYP.
PROJECTED ROOF FEATURE WITH ACM
PROFILE AND SOFFIT
ANODIZED ALUMINUM CURTAINWALL
SYSTEM
VEHICULAR CABLE CRASH BARRIER, TYP.
MODULAR BRICK VENEER W/ ACCENT
DETAILING AT OPENINGS AND
HORIZONTAL BANDS
HANGER-SUPPORTED CANOPY WITH
BRACKETS AND METAL PROFILE
PROVIDE GRANITE WATER TABLE AT PIERS
PROVIDE TUBE STEEL TO SUPPORT
UPPER WINDOW UNITS PRIMARY GARAGE ACCESS FROM
EUCLID AVENUE
EIFS-1
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 4:29:25 PM C:\Users\kwarren\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_kwarrenLJ2JT.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
BUILDING ELEVATIONS
20SPN100
08.03.2021
JG/AW/KW
CHARLOTTE, NC
A4.02
Revisions
No. Description Date
SCALE: 1/16" = 1'-0"A4.02
1 EUCLID AVE. ELEVATION
1. COLORS ARE DIAGRAMATIC AND DO NOT REFLECT
FINAL MATERIAL SELECTIONS. ALL FINAL SELECTIONS
TO BE APPROVED BY OWNER AND ARCHITECT.
2. ALLOWED OPENINGS ARE UNLIMITED ON ALL
ELEVATIONS EXCEPT THE NORTH. PROXIMITY OF THE
NORTH ELEVATION TO THE PEROPERTY LINE LIMITS THE
OPENINGS AT ANY NON-PARKING LEVEL TO 45%
(NCBC T705.8)
3. WINDOW TRIM TO MATCH COLOR OF
SURROUNDING FINISH UNLESS NOTED OTHERWISE.
4. BRICK CONTROL JOINES ARE TO BE FREE OF MORTAR
AND PROVIDED WITH BACKER ROD AND SEALANT.
5. AT ALL RECESSES IN THE BUILDING FACADE, EXTERIOR
MATERIAL IS TO BE CONTINUED TO THE INSIDE
CORNER UNLESS NOTED OTHERWISE.
GENERAL NOTES
MATERIAL KEY NOTES
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
BRK-1:
STANDARD MASONRY VENEER, RUNNING
BOND.
COLOR: TBD
BRK-2:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD
BRK-3:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD, ACCENT
EIFS-1:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
EIFS-2:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
FC-1:
FIBER CEMENT PANEL RAINSCREEN SYSTEM WITH
APPLIED TRIM
COLOR: TBD
MTL SCREEN:
DECORATIVE METAL SCREENING SYSTEM WITH
REQUIRED STRUCTURAL FRAMING AND SUPPORT.
ALTERNATE TO INCLUDE FABRIC SYSTEM IN LIEU OF
METAL SCREEN
LEVEL 1-H
EL 713' -6"
LEVEL 3
EL 733' -6"
LEVEL 2
EL 722' -10"
LEVEL 1-M
EL 711' -6"
LEVEL 4
EL 744' -2"
LEVEL 5
EL 754' -10"
LEVEL 6
EL 765' -6"
LEVEL 7
EL 776' -2"
LEVEL 8
EL 786' -10"
LEVEL 9
EL 797' -6"
LEVEL 10
EL 808' -2"
LEVEL 11
EL 818' -10"
LEVEL 12
EL 832' -10"
LEVEL 13
EL 844' -10"
LEVEL 14
EL 855' -6"
LEVEL 15
EL 866' -2"
LEVEL 16
EL 876' -10"
LEVEL 17
EL 887' -6"
LEVEL 18
EL 898' -2"
LEVEL 19
EL 908' -10"
LEVEL 20
EL 919' -6"
LEVEL 21
EL 930' -2"
LEVEL 22
EL 940' -10"
LEVEL 23
EL 951' -6"
LEVEL 25
EL 974' -2"
TOWER ROOF
EL 998' -2"
LEVEL 26
EL 986' -2"12' - 0"12' - 0"12' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"12' - 0"14' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"9' - 4"2' - 0"286' - 8"LEVEL 24
EL 962' -2"
DW ROOF BRG
EL 785' -6"
ROOF FEATURE
EL 1010' -2"
EIFS-2
EIFS-1
EIFS-1
BRK-1
BRK-2
FC-1
ANODIZED ALUMINUM
CURTAINWALL SYSTEM
PROJECTED ROOF FEATURE
WITH ACM PROFILE AND SOFFIT
OVERBUILT FRAMING WITH EIFS FINISH
ANODIZED ALUMINUM WINDOW WALL
SYSTEM W/ INTEGRAL MULLION CAPS
METAL PANEL COVER INTEGRAL WITH
WINDOW SYSTEM AT SLAB EDGES
PROVIDE EIFS OVER LIGHT-GAUGE FRAMING
AT RAISED WINDOW UNITS, TYP.
60"+ GLASS GUARDRAIL SYSTEM
AT AMENITY DECK
OVERBUILT FIBER-CEMENT WRAPPED
CORNICE PROFILE
VEHICULAR CABLE CRASH BARRIER, TYP.
SERVICE ACESS POINTS
ON PRIVATE DRIVE
VINYL WINDOW ASSEMBLY WITH DOUBLE-
HUNG AND FIXED UNITS. TYP ASSEMBLY IS
8'W X 6'H
ANODIZED STOREFRONT WINDOW SYSTEM
W/ INTEGRAL MULLION CAPS
PREFINISHED ALUMINUM COPING, TYP. AT
PARAPET COPING CONDITIONS
METAL SCREENING AT PARKING DECK
MODULAR BRICK VENEER W/ ACCENT
DETAILING AT OPENINGS AND
HORIZONTAL BANDS
PROVIDE SOLDIER COURSE AT WINDOW
HEADS AND ROWLOCK SILLS, TYP.
STEEL FRAMED CONNECTOR BRIDGE WITH
INDEPENDENT COLUMN SUPPORTS FOR
PEDESTRIAN ACCESS BETWEEN MIDRISE
AND PARKING DECK
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 4:29:35 PM C:\Users\kwarren\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_kwarrenLJ2JT.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
BUILDING ELEVATIONS
20SPN100
08.03.2021
JG/AW/KW
CHARLOTTE, NC
A4.03
Revisions
No. Description Date
SCALE: 1/16" = 1'-0"A4.03
1 I-277 ELEVATION
1. COLORS ARE DIAGRAMATIC AND DO NOT REFLECT
FINAL MATERIAL SELECTIONS. ALL FINAL SELECTIONS
TO BE APPROVED BY OWNER AND ARCHITECT.
2. ALLOWED OPENINGS ARE UNLIMITED ON ALL
ELEVATIONS EXCEPT THE NORTH. PROXIMITY OF THE
NORTH ELEVATION TO THE PEROPERTY LINE LIMITS THE
OPENINGS AT ANY NON-PARKING LEVEL TO 45%
(NCBC T705.8)
3. WINDOW TRIM TO MATCH COLOR OF
SURROUNDING FINISH UNLESS NOTED OTHERWISE.
4. BRICK CONTROL JOINES ARE TO BE FREE OF MORTAR
AND PROVIDED WITH BACKER ROD AND SEALANT.
5. AT ALL RECESSES IN THE BUILDING FACADE, EXTERIOR
MATERIAL IS TO BE CONTINUED TO THE INSIDE
CORNER UNLESS NOTED OTHERWISE.
GENERAL NOTES
MATERIAL KEY NOTES
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
BRK-1:
STANDARD MASONRY VENEER, RUNNING
BOND.
COLOR: TBD
BRK-2:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD
BRK-3:
LARGE-FORMAT MASONRY VENEER
(ROCKCAST 12"x24", SMOOTH)
COLOR: TBD, ACCENT
EIFS-1:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
EIFS-2:
MIN. 2" EIFS VENEER SYSTEM(SMOOTH FINISH)WITH
INTEGRAL REVEAL AND ACCENT BANDS (STOTHERM)
COLOR: TBD
FC-1:
FIBER CEMENT PANEL RAINSCREEN SYSTEM WITH
APPLIED TRIM
COLOR: TBD
MTL SCREEN:
DECORATIVE METAL SCREENING SYSTEM WITH
REQUIRED STRUCTURAL FRAMING AND SUPPORT.
ALTERNATE TO INCLUDE FABRIC SYSTEM IN LIEU OF
METAL SCREEN
LEVEL 1-H
EL 713' -6"
LEVEL 1-H
EL 713' -6"
LEVEL 3
EL 733' -6"
LEVEL 2
EL 722' -10"
LEVEL 1-M
EL 711' -6"
LEVEL 1-M
EL 711' -6"
LEVEL 3.5
EL 738' -10"
LEVEL 4
EL 744' -2"
LEVEL 5
EL 754' -10"
LEVEL 6
EL 765' -6"
LEVEL 7
EL 776' -2"
LEVEL 8
EL 786' -10"
LEVEL 9
EL 797' -6"
LEVEL 10
EL 808' -2"
LEVEL 4.5
EL 749' -6"
LEVEL 5.5
EL 760' -2"
LEVEL 6.5
EL 770' -10"
LEVEL 7.5
EL 781' -6"
LEVEL 8.5
EL 792' -2"
LEVEL 11
EL 818' -10"
LEVEL 12
EL 832' -10"
LEVEL 12
EL 832' -10"
LEVEL 13
EL 844' -10"
LEVEL 14
EL 855' -6"
LEVEL 15
EL 866' -2"
LEVEL 16
EL 876' -10"
LEVEL 17
EL 887' -6"
LEVEL 18
EL 898' -2"
LEVEL 19
EL 908' -10"
LEVEL 20
EL 919' -6"
LEVEL 21
EL 930' -2"
LEVEL 22
EL 940' -10"
LEVEL 23
EL 951' -6"
LEVEL 25
EL 974' -2"
TOWER ROOF
EL 998' -2"
LEVEL 26
EL 986' -2"286' - 8"LEVEL 9.5
EL 802' -10"
LEVEL 10.5
EL 813' -6"
LEVEL 2.5
EL 727' -6"
LEVEL 24
EL 962' -2"2' - 0" 14' - 0" 11' - 4" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 19' - 4" 12' - 0" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 12' - 0" 12' - 0" 12' - 0"2' - 0" 9' - 4" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 14' - 0"
LEVELS 1 THROUGH LEVEL 13 ON THIS ELEVATION REQUIRES LIMITED PERCENTAGE
OF OPENING (45%) DUE TO PROXIMITY TO PROPERTY LINE
DW ROOF BRG
EL 785' -6"
ROOF FEATURE
EL 1010' -2"
EIFS-2
EIFS-1EIFS-2
EIFS-1 EIFS-1
BRK-2
FC-1
ANODIZED ALUMINUM
CURTAINWALL SYSTEM
PROJECTED ROOF FEATURE
WITH ACM PROFILE AND SOFFIT
OVERBUILT FRAMING WITH
EIFS FINISH
ANODIZED ALUMINUM WINDOW WALL
SYSTEM W/ INTEGRAL MULLION CAPS
METAL PANEL COVER INTEGRAL WITH
WINDOW SYSTEM AT SLAB EDGES
PROVIDE EIFS OVER LIGHT-GAUGE FRAMING
AT RAISED WINDOW UNITS, TYP.
60"+ GLASS GUARDRAIL SYSTEM AT
AMENITY DECK
VEHICULAR CABLE CRASH BARRIER, TYP.
METAL SCREENING AT PARKING DECK
OVERBUILT FIBER-
CEMENT WRAPPED
CORNICE PROFILE
PROVIDE SOLDIER
COURSE AT WINDOW
HEADS AND ROWLOCK
SILLS, TYP.
GUARD-HEIGHT PREFINISHED ALUMINUM
RAILING SYSTEM WITH HORIZONTAL BARS
SITE WALLS TO BE MASONRY VENEER
WITH CAST STONE CAP, TYP.
STEEL FRAMED CONNECTOR BRIDGE WITH
INDEPENDENT COLUMN SUPPORTS FOR
PEDESTRIAN ACCESS BETWEEN MIDRISE
AND PARKING DECK
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 4:29:55 PM C:\Users\kwarren\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_kwarrenLJ2JT.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
BUILDING ELEVATIONS
20SPN100
08.03.2021
JG/AW/KW
CHARLOTTE, NC
A4.04
Revisions
No. Description Date
SCALE: 1/16" = 1'-0"A4.04
1 UPTOWN ELEVATION (NORTH)
KEY NOTE/MATERIAL LEGEND
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
FCT-1:FIBER CEMENT TRIM BOARD
COLOR: TBD
ALG-1:POWDER COATED ALUMINUM GUARD RAIL
COLOR: TBD
AAU-1:ALUMINUM ARCHITECTURAL LOUVER UNIT
COLOR: TBD
FCT-2:FIBER CEMENT TRIM BOARD
COLOR: TBD
FCL-1:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-2:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-3:FIBER CEMENT LAP SIDING
COLOR: TBD
BRK-1:MASONRY VENEER, RUNNING BOND
COLOR: TBD
FCL-4:FIBER CEMENT LAP SIDING
COLOR: TBD
FCP-3:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-4:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
MCA-1:METAL CANOPY
COLOR: TBD
FCP-2:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-1:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
1. BALCONY RAIL TO BE POWDER-COATED ALUMINUM. FINISHED
COLOR TO BE APPROVED BY OWNER AND ARCHITECT.
2. WINDOW TRIM TO MATCH COLOR OF SURROUNDING FINISH.
3. AT MASONRY VENEER PROVIDE CONTROL JOINTS PER BIA
STANDARDS AND VERTICAL CONTROL JOINTS AT CHANGES IN
WALL HEIGHT, NEAR CORNERS ON RETURN WALL 2 FEET BACK
FROM FACE OF MAIN VENEER, AT INSIDE CORNER OF SETBACKS,
AT OFFSETS, AND ALIGNED WITH VERTICAL EDGES OF WINDOWS.
PROVIDE HORIZONTAL CONTROL JOINTS AT LOOSE LINTELS,
EXTEND IN 1/4" PAST EDGE OF LINTEL.
4. BRICK CONTROL JOINTS ARE TO BE FREE OF MORTAR AND
PROVIDED WITH BACKER ROD AND SEALANT.
5. PROVIDE CORNER MASONRY UNIT AT ALL MASONRY VENEER
CORNER RETURNS.
6. USE FIBER CEMENT PANEL WITH FIBER CEMENT TRIM, FIBER
CEMENT LAP SIDING AND MASONRY VENEER AS BASIS OF
DESIGN.
7. PAINTED FIBER CEMENT COLORS TO BE APPROVED BY
ARCHITECT.
8. EXTERIOR MATERIALS, DETAILING, AND COLORS TO WRAP
CORNER AT BALCONY, ALCOVE, AND PARAPET CONDITIONS
AND TERMINATE AT INSIDE CORNER, UNLESS NOTED OTHERWISE.
9. G.C. TO PROVIDE CONTINUOUS PRE-FINISHED ALUM. COPING
AT ALL PARAPET WALLS, INCLUDING SIDE FACE OF STEPPED
PARAPET.
10. ALL WINDOW SILLS IN BRICK VENEER TO BE ROWLOCK SILL
COURSE.
11. POOL COURTYARD: AT LEVEL MF-0 PATIOS IN POOL
COURTYARD, PROVIDE 42" HIGH ALUMINUM GUARDRAIL. USE
WINDOW LIMITERS FOR ALL OPERABLE WINDOWS ON LEVEL MF-B
WHICH OPEN TO POOL AND ARE NOT BEHIND A 42" HIGH
GUARDRAIL.
GENERAL ELEVATION NOTES
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
B1 B13B7
5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"90' - 0"FCL-2
FCP-3
BRK-1
FCP-3BRK-1 BRK-1
FCL-2
ALG-1
FCL-1
FCL-2
FCP-3
FCL-2
FCL-1AAU-1
FCP-2
FCL-4
BRK-1
FCL-2
T.O. PARAPET
EL 789' -2"FCP-4
FCP-4
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
2
A5.01
1
A5.01 BBBL
90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-2
FCP-3
BRK-1BRK-1
FCL-4
ALG-1
MCA-1
PEDESTRIAN BRIDGE
WITH COVER TO
PARKING GARAGE
FCP-4 FCL-2 FCL-4
AAU-1
FCP-2
S3S4S4
FCL-1FCP-4
T.O. PARAPET
EL 789' -2"
S5
1
A5.20
(DRIVE) (DRIVE)
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 5:23:56 PM C:\Users\jmarshall\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - MF_JMarshall_BBM.rvt
RADIUS DILWORTH
ENCLAVE
DESIGN DEVELOPEMENT
PROGRESS SET
BUILDING ELEVATIONS
20SPN110
08.03.2021
DC
A4.01
CHARLOTTE, NC
SOUTHWESTNORTH EASTNORTHWESTNORTH EASTPOOL
DRIVE
W E S
NTYP CORNER
W
I-277KEY PLAN
SCALE: 3/32" = 1'-0"A4.01
1 ELEVATION - SOUTH
SCALE: 3/32" = 1'-0"A4.01
2 ELEVATION - WEST (FRONT)
Revisions
No. Description Date
KEY NOTE/MATERIAL LEGEND
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
FCT-1:FIBER CEMENT TRIM BOARD
COLOR: TBD
ALG-1:POWDER COATED ALUMINUM GUARD RAIL
COLOR: TBD
AAU-1:ALUMINUM ARCHITECTURAL LOUVER UNIT
COLOR: TBD
FCT-2:FIBER CEMENT TRIM BOARD
COLOR: TBD
FCL-1:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-2:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-3:FIBER CEMENT LAP SIDING
COLOR: TBD
BRK-1:MASONRY VENEER, RUNNING BOND
COLOR: TBD
FCL-4:FIBER CEMENT LAP SIDING
COLOR: TBD
FCP-3:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-4:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
MCA-1:METAL CANOPY
COLOR: TBD
FCP-2:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-1:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
1. BALCONY RAIL TO BE POWDER-COATED ALUMINUM. FINISHED
COLOR TO BE APPROVED BY OWNER AND ARCHITECT.
2. WINDOW TRIM TO MATCH COLOR OF SURROUNDING FINISH.
3. AT MASONRY VENEER PROVIDE CONTROL JOINTS PER BIA
STANDARDS AND VERTICAL CONTROL JOINTS AT CHANGES IN
WALL HEIGHT, NEAR CORNERS ON RETURN WALL 2 FEET BACK
FROM FACE OF MAIN VENEER, AT INSIDE CORNER OF SETBACKS,
AT OFFSETS, AND ALIGNED WITH VERTICAL EDGES OF WINDOWS.
PROVIDE HORIZONTAL CONTROL JOINTS AT LOOSE LINTELS,
EXTEND IN 1/4" PAST EDGE OF LINTEL.
4. BRICK CONTROL JOINTS ARE TO BE FREE OF MORTAR AND
PROVIDED WITH BACKER ROD AND SEALANT.
5. PROVIDE CORNER MASONRY UNIT AT ALL MASONRY VENEER
CORNER RETURNS.
6. USE FIBER CEMENT PANEL WITH FIBER CEMENT TRIM, FIBER
CEMENT LAP SIDING AND MASONRY VENEER AS BASIS OF
DESIGN.
7. PAINTED FIBER CEMENT COLORS TO BE APPROVED BY
ARCHITECT.
8. EXTERIOR MATERIALS, DETAILING, AND COLORS TO WRAP
CORNER AT BALCONY, ALCOVE, AND PARAPET CONDITIONS
AND TERMINATE AT INSIDE CORNER, UNLESS NOTED OTHERWISE.
9. G.C. TO PROVIDE CONTINUOUS PRE-FINISHED ALUM. COPING
AT ALL PARAPET WALLS, INCLUDING SIDE FACE OF STEPPED
PARAPET.
10. ALL WINDOW SILLS IN BRICK VENEER TO BE ROWLOCK SILL
COURSE.
11. POOL COURTYARD: AT LEVEL MF-0 PATIOS IN POOL
COURTYARD, PROVIDE 42" HIGH ALUMINUM GUARDRAIL. USE
WINDOW LIMITERS FOR ALL OPERABLE WINDOWS ON LEVEL MF-B
WHICH OPEN TO POOL AND ARE NOT BEHIND A 42" HIGH
GUARDRAIL.
GENERAL ELEVATION NOTES
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
1
A5.01 BJ
90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-4
FCP-3
FCL-2
FCL-1
BRK-1
ALG-1
FCL-2
FCP-4
T.O. PARAPET
EL 789' -2"
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
B2 B1B3B5B6B4
90' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"9' - 10"5' - 6"BRK-1
FCL-4
FCL-1
FCP-4
FCL-1 FCL-2
FCP-3BRK-1
FCL-4
ALG-1
FCL-1
FCL-2
FCP-3
DRIVE RETAINING WALL
T.O. PARAPET
EL 789' -2"
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
1
A5.01
BLBJBK
DRIVE UP TO
PRIVATE ST.90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-1
FCL-2
FCL-4
FCP-3
BRK-1
ALG-1
FCL-1
FCL-2FCP-4
T.O. PARAPET
EL 789' -2"
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"84' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-2
FCP-1
ALG-1
FCP-4
FCL-4
FCP-3
BRK-1
FCL-1
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 5:24:03 PM C:\Users\jmarshall\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - MF_JMarshall_BBM.rvt
RADIUS DILWORTH
ENCLAVE
DESIGN DEVELOPEMENT
PROGRESS SET
BUILDING ELEVATIONS
20SPN110
08.03.2021
DC
A4.02
CHARLOTTE, NC
SOUTHWESTNORTH EASTNORTHWESTNORTH EASTPOOL
DRIVE
W E S
NTYP CORNER
W
I
-277KEY PLAN
SCALE: 3/32" = 1'-0"A4.02
3 ELEVATION - DRIVE EAST
SCALE: 3/32" = 1'-0"A4.02
1 ELEVATION - NORTH
SCALE: 3/32" = 1'-0"A4.02
2 ELEVATION - DRIVE WEST
SCALE: 3/32" = 1'-0"A4.02
4
ELEVATION - TYPICAL CORNER
BALCONY
Revisions
No. Description Date
KEY NOTE/MATERIAL LEGEND
NOTE: COLORS ARE FOR DIAGRAMATIC PURPOSES ONLY
FCT-1:FIBER CEMENT TRIM BOARD
COLOR: TBD
ALG-1:POWDER COATED ALUMINUM GUARD RAIL
COLOR: TBD
AAU-1:ALUMINUM ARCHITECTURAL LOUVER UNIT
COLOR: TBD
FCT-2:FIBER CEMENT TRIM BOARD
COLOR: TBD
FCL-1:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-2:FIBER CEMENT LAP SIDING
COLOR: TBD
FCL-3:FIBER CEMENT LAP SIDING
COLOR: TBD
BRK-1:MASONRY VENEER, RUNNING BOND
COLOR: TBD
FCL-4:FIBER CEMENT LAP SIDING
COLOR: TBD
FCP-3:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-4:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
MCA-1:METAL CANOPY
COLOR: TBD
FCP-2:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
FCP-1:FIBER CEMENT PANEL WITH F.C. TRIM
COLOR: TBD
1. BALCONY RAIL TO BE POWDER-COATED ALUMINUM. FINISHED
COLOR TO BE APPROVED BY OWNER AND ARCHITECT.
2. WINDOW TRIM TO MATCH COLOR OF SURROUNDING FINISH.
3. AT MASONRY VENEER PROVIDE CONTROL JOINTS PER BIA
STANDARDS AND VERTICAL CONTROL JOINTS AT CHANGES IN
WALL HEIGHT, NEAR CORNERS ON RETURN WALL 2 FEET BACK
FROM FACE OF MAIN VENEER, AT INSIDE CORNER OF SETBACKS,
AT OFFSETS, AND ALIGNED WITH VERTICAL EDGES OF WINDOWS.
PROVIDE HORIZONTAL CONTROL JOINTS AT LOOSE LINTELS,
EXTEND IN 1/4" PAST EDGE OF LINTEL.
4. BRICK CONTROL JOINTS ARE TO BE FREE OF MORTAR AND
PROVIDED WITH BACKER ROD AND SEALANT.
5. PROVIDE CORNER MASONRY UNIT AT ALL MASONRY VENEER
CORNER RETURNS.
6. USE FIBER CEMENT PANEL WITH FIBER CEMENT TRIM, FIBER
CEMENT LAP SIDING AND MASONRY VENEER AS BASIS OF
DESIGN.
7. PAINTED FIBER CEMENT COLORS TO BE APPROVED BY
ARCHITECT.
8. EXTERIOR MATERIALS, DETAILING, AND COLORS TO WRAP
CORNER AT BALCONY, ALCOVE, AND PARAPET CONDITIONS
AND TERMINATE AT INSIDE CORNER, UNLESS NOTED OTHERWISE.
9. G.C. TO PROVIDE CONTINUOUS PRE-FINISHED ALUM. COPING
AT ALL PARAPET WALLS, INCLUDING SIDE FACE OF STEPPED
PARAPET.
10. ALL WINDOW SILLS IN BRICK VENEER TO BE ROWLOCK SILL
COURSE.
11. POOL COURTYARD: AT LEVEL MF-0 PATIOS IN POOL
COURTYARD, PROVIDE 42" HIGH ALUMINUM GUARDRAIL. USE
WINDOW LIMITERS FOR ALL OPERABLE WINDOWS ON LEVEL MF-B
WHICH OPEN TO POOL AND ARE NOT BEHIND A 42" HIGH
GUARDRAIL.
GENERAL ELEVATION NOTES
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
D26D27D28 D29D33
90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-2
BRK-1
FCL-4
FCP-3
FCL-4
ALG-1
FCP-4
FCP-2
FCL-2
FCL-2
T.O. PARAPET
EL 789' -2"FCP-4
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
D24D25
90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-2
BRK-1
FCP-3
ALG-1
BRK-1
ALG-1
FCL-2
FCL-2
FCP-4 FCL-1 FCL-4
T.O. PARAPET
EL 789' -2"FCP-4
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
B11B12B13
90' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"9' - 10"5' - 6"FCL-4
FCP-3
BRK-1
FCL-2 FCP-1
FCL-4
ALG-1
FCP-4T.O. PARAPET
EL 789' -2"
AVERAGE GRADE
EL 701' -4"
MAX BLDG HT -TYPE III-A
EL 786' -7"
LEVEL MF-3 (T.O.S.)
EL 731' -2"
LEVEL MF-4 (T.O.D.)
EL 741' -10"
LEVEL MF-5 (T.O.D.)
EL 752' -6"
LEVEL MF-6 (T.O.D.)
EL 763' -2"
LEVEL MF-7 (T.O.D.)
EL 773' -10"
LEVEL MF-2 (T.O.S.)
EL 720' -6"
LEVEL MF-1 (T.O.S.)
EL 709' -10"
LEVEL MF-B (T.O.S.)
EL 699' -2"
MF-ROOF BEARING
EL 783' -8"
D27D28D34
90' - 0"5' - 6"9' - 10"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"FCL-2
ALG-1
BRK-1
FCP-2
FCL-4
FCP-4
T.O. PARAPET
EL 789' -2"
FCP-4
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 5:24:10 PM C:\Users\jmarshall\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - MF_JMarshall_BBM.rvt
RADIUS DILWORTH
ENCLAVE
DESIGN DEVELOPEMENT
PROGRESS SET
BUILDING ELEVATIONS
20SPN110
08.03.2021
DC
A4.03
CHARLOTTE, NC
SOUTHWESTNORTH EASTNORTHWESTNORTH EASTPOOL
DRIVE
W E S
NTYP CORNER
W
I-277KEY PLAN
SCALE: 3/32" = 1'-0"A4.03
1 ELEVATION - NORTH WEST
SCALE: 3/32" = 1'-0"A4.03
2 ELEVATION - NORTH EAST
SCALE: 3/32" = 1'-0"A4.03
3 ELEVATION - SOUTH POOL
SCALE: 3/32" = 1'-0"A4.03
4 ELEVATION - NORTH POOL
Revisions
No. Description Date
712711710705700705700695700703
695690
690695695691691695695690695695696710709710710715715710711713 713714
708TSSTTLD
LD
LD
LD LDLD LDLDLDLDLDLDLDLD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD
LD
LD LD LD LD
LDLDLDLDLDLDLDLDLDLDLDLDLDLD
LD
LD
LD
LD 715713 714712
711710
709708707705
702
700
698699698697
6
91
694
698
699TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->RADIUSDILWORTHSPANDREL DEVELOPMENTPARTNERS615 E MOREHEAD STCHARLOTTE, NC 282021019447EROSION CONTROL PLANPHASE IIN/A######C2-028/3/2021 6:44 PM ALEX RHODE N:\_2019\1019447\CAD\DOCUMENTATION\1019447_PLN_ECP.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMSITEE MOREHEAD STEU
C
L
I
D
A
VE
ROY
AL
CT
MY
R
T
L
E
A
VE
ORI
O
LE
S
T
S
MC
DO
WE
L
L
STLEXINGTON AVESCHEMATIC DESIGN02-23-20211PRICING SETNOT FORCONSTRUCTION08-03-2021SEAL033804SEALC-0653 ---- 1" = 30'6030015PROP. LIMITS OFDISTURBANCE (TYP.)PROP. SILT FENCE (TYP.)PROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)PROP. INLETPROTECTION (TYP.)EROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT JAMES MOORE WITH NCDEQ @ 704-235-2138 TO ADVISE ONSTART DATE AND SCHEDULE PRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN 10'REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.11.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.12.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.13.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.14.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.15.ALL DISTANCES ARE HORIZONTAL GROUND.16.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.17.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA18.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.19.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.20.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASEXISTING ASPHALT TO BE REMOVEDLIMITS OF DISTURBANCELEGENDLDTEMPORARY SILT FENCE (CLDS 30.06A)EXISTING CURB/WALL TO BE REMOVEDTREE PROTECTION (CLDS 40.02)PROPERTY LINEPROP. TREEPROTECTION (TYP.)PROP. TREEPROTECTION (TYP.)PROP. INLETPROTECTION (TYP.)PROP. INLETPROTECTION (TYP.)E. MOREHEAD ST
EUCLID AVECONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OREXISTING STRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURSPRIOR TO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODEAND IS SUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.5.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.6.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.7.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.8.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES AREIN PLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.9.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.10.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURESAS INDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSIONCONTROL INSPECTOR.11.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDINGIS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.12.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.13.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK ANDAFTER EVERY STORM EVENT OF 6" OR GREATER BY A CERTIFIED INSPECTOR. IFANY FAILURES ARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.14.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCEWITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGNMANUAL, U.S. DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROLORDINANCE, AND THE CHARLOTTE MECKLENBURG LAND DEVELOPMENTSTANDARDS.15.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING,PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.16.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT BASIN TO BEMUCKED OUT AND FILLED. (PHASE 3)PROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)BASEMENT PAD: 698.00711 EAST MOREHEAD STPARCEL #: 12517402NCDOT R/W
CDOT R/WPROPERTY LINE (TYP.)EX. STORM AND BMP TO REMAIN IN PLACE UNTIL PROP.STORM AND BMP ARE INSTALLED.DRAINAGE FROM 521 EAST MOREHEAD AND EXISTINGPARKING DECK TO BE BYPASSED TO FES.PROP. LIMITS OFDISTURBANCE ALONG PROPERTY LINE.NOTE: NO ENCROACHMENTS ALLOWED INNCDOT CONTROLLED ACCESS UNTILFINAL APPROVAL FROM THE STATEPROP. LIMITS OFDISTURBANCE ALONG PROPERTYLINE.NOTE: LOWER LEVEL ACCESS TOPARKING DECK WILL BE CLOSEDDURING CONSTRUCTIONTOTAL DENUDED AREA:3.30 ACRES ON-SITE +2.38 ACRES OFF-SITE IMPERVIOUS= 5.38 ACRESPERMANENT STORM PIPE ANDSTRUCTURES TO BE INSTALLED INPHASE 1. BYPASS 521 E MOREHEADDRAINAGE TO OUTLET .REFER TO SHEET C3.00 FOR FULLSTORMWATER LAYOUTPROP. TEMPORARY DIVERSIONDITCH BEFORE FULL STORMSYSTEM BUILDOUT.PROP. TEMPORARYDIVERSION DITCH (TYP.)Exhibit 4 – Grading MapRed Carpet Inn Brownfields SiteAKA Morehead OverlookNCBP #23070-19-060615 East Morehead StreetCharlotte, North Carolina
Exhibit 4 –Grading / Cut and Fill Heat Map
Red Carpet Inn Brownfields Site
AKA Morehead Overlook
NCBP #23070-19-060
615 East Morehead Street
Charlotte,North Carolina
EXHIBIT NO.
File Path:
Date:
PM:
Drawn By:
Checked By:
Approved By:
1 in = 100 ft
Project No.
Scale:
5
WOF
WOF
MNM
MNM 2701 Westport Road Charlotte, North Carolina 28208Phone: (704) 509-1777 Fax: (704) 509-1888
Soil Sample Location Map w/ Grading Overlay
Red Carpet Inn Brownfields Site(AKA Morehead Overlook)NCBP #23070-19-060615 East Morehead StreetCharlotte, Mecklenburg County, North Carolina8/23/2021
71197661
0 200100Feet
Legend
Site BoundaryTax ParcelsSoil SampleGroundwater / Soil Sample
East M
orehead Street Euclid AvenueRoyal Court
B-11/MW-10
B-6/MW-6
B-8/MW-7
B-7
P-2/TW-1
P-5
P-1
P-3
P-8
P-4
P-7
P-6
P-9
B-5/MW-3
B-8/MW-1
B-9/MW-2
B-10/MW-4
GP-9GP-8
GP-7
BG-1
BG-2
S-1
S-2/TW-2
S-3/TW-3
S-4/TW-4
@A
@A
@A
@A
@A
@A
@A
@A
@A
@A
#*
#*
#*
#*
#*
@A
@A@A
@A
#*
#*
#*
#*
#*
@A
@A
@A
@A
EXHIBIT NO.
File Path:
Date:
PM:
Drawn By:
Checked By:
Approved By:
1 in = 100 ft
Project No.
Scale:
6
WOF
WOF
MNM
MNM 2701 Westport Road Charlotte, North Carolina 28208Phone: (704) 509-1777 Fax: (704) 509-1888
Red Carpet Inn Brownfields Site(AKA Morehead Overlook)NCBP #23070-19-060615 East Morehead Street4/30/2021 Charlotte, Mecklenburg County, North Carolina
71197661
³
0 200100Feet
Legend
Site Boundary
@A Historical Vapor Intrusion GWSL Exceedance
@A Historical Groundwater Sample
#*2020 Soil Vapor Sample
#*2021 Soil Vapor Sample
East M
orehead Street Euclid AvenueRoyal Court
B-11/MW-10
B-6/MW-6
B-8/MW-7
MW-11
P-2/TW-1
P-10/TW-2
B-5/MW-3
B-8/MW-1
B-9/MW-2
B-10/MW-4
HHTW-4
HHTW-5
S-2/TW-2
S-3/TW-3
S-4/TW-4
SV-03
SV-04
SV-05
SV-02
SV-01
Garage
R
etail ResidentialResidentialResidential
2021-SV-01
2021-SV-02
2021-SV-03
2021-SV-04
2021-SV-05
B
C
B
C
B
EXISTING 5
LEVEL OFFICE
BUILDING
EUCLID AVEEAST MOREHEAD STREETEXISTING DUKE ENERGY SUBSTATIONNEW PRIVATE DRIVE150' LONG FIRE ACCESS
EXISTING 1 LEVEL PARKING STRUCTURE
26' SETBACK ALONG
MOREHEAD
PROPERTY LINE
16' SETBACK ALONG EUCLID
GROUND LEVELS MF BASEMENT
MAIN LOBBY
RETAIL
RETAIL
TRASH
MOVE-IN
GENERATOR TRASH
RISER
FCC
TELE/DATA
POE
ELECTRICAL
RESIDENTIAL
RESIDENTIAL
PLAZA /
FORECOURT
SERVICE
R
AMENITY
RESIDENTIAL
PARKING ENTRANCE /
EXIT AT PRIVATE DRIVE
SPEED RAMP UP
TO TYPICAL
PARKING LEVELS
ENCLAVE UTILITY YARD
MAIL
T T T T
OVERLOOK UTILITY YARD
PROJECT # /
1435 WEST MOREHEAD STREET
SUITE 160
CHARLOTTE, NC 28208
704.334.1716
BEACHAM BUNCE + MANLEY ARCHITECTURE PLLC
COPYRIGHT 2021 BB+M ARCHITECTURE PLLC.
WWW.BBM-ARCH.COM
LOCATION /
DATE /
DRAWN /
PRELIMINARY:
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
8/3/2021 6:01:35 PM C:\Users\jgraham\Documents\Revit Local Files\SPANDREL_CENTRAL_R20 - Tower_jgraham@bbm-arch.com.rvt
RADIUS DILWORTH
OVERLOOK
DESIGN DEVELOPMENT
PROGRESS
ARCHITECTURAL SITE
PLAN
20SPN100
08.03.2021
JG/KW
CHARLOTTE, NC
A0.01SCALE: 3/64" = 1'-0"A0.01
1 OVERALL SITE PLAN
Revisions
No. Description Date
Activity IDActivity NameRemDurStartFinishCommentsProject: MHOL-19-1 Morehead Overlook - 19.1 - Comfortable Case Schedule 7-30-21 - DraftProject: MHOL-19-1 Morehead Overlook - 19.1 - Comfortable Case Schedule 7-30-21 - Draft84717-May-2119-Sep-24WBS: MHOL-19-1.0 SUMMARY & MILESTONEWBS: MHOL-19-1.0 SUMMARY & MILESTONE79204-Aug-2119-Sep-24LOE.1000Summary - Design & Permitting13804-Aug-2121-Feb-22MS.2040Mobilize/ Start Construction022-Feb-22MS.9350Owner Turnover L14 - L17 - Building A&D028-Aug-24MS.9360Owner Turnover L18 - L21 & L13 - Building A&D005-Sep-24MS.9370Owner Turnover L22 - L25 - Building A&D018-Sep-24MS.9300Project Substantial Completion019-Sep-24MS.9380Owner Turnover L26 - L30 - Building A&D019-Sep-24WBS: MHOL-19-1.0.1 SUMMARY & MILESTONE A&DWBS: MHOL-19-1.0.1 SUMMARY & MILESTONE A&D65422-Feb-2219-Sep-24WBS: MHOL-19-1.0.2 SUMMARY & MILESTONE BWBS: MHOL-19-1.0.2 SUMMARY & MILESTONE B42312-Sep-2213-May-24WBS: MHOL-19-1.0.3 SUMMARY & MILESTONE CWBS: MHOL-19-1.0.3 SUMMARY & MILESTONE C46122-Feb-2218-Dec-23WBS: MHOL-19-1.11 ENGINEERING & PERMITSWBS: MHOL-19-1.11 ENGINEERING & PERMITS23817-May-2125-Apr-22A1000TIA Submission7817-May-21*03-Sep-21ENG.4080DD Documents Progress Set less Specs4501-Jun-2103-Aug-21MS.9540Design Assist Constraints for Concrete Finalized003-Aug-21ENG.3000100% DD Documents and Specs1804-Aug-2127-Aug-21MS.9560Remaining Design Assist On-Board027-Aug-21Need Specs to really lock down the DA guys.MS.9550Design Assist Concrete On-Board027-Aug-21ENG.4070100% DD Pricing Update Deliverable Submitted2030-Aug-2127-Sep-21ENG.405050% CD Development2030-Aug-2127-Sep-21A1030Land Development Submitted to City6607-Sep-2110-Dec-21A1020Land Development Submitted to NCDOT11507-Sep-2121-Feb-225.5 Months for NCDOT ReviewA1110Enclave Sanitary Sewer DOT Permit2007-Sep-2104-Oct-21ENG.406090% CD Development2028-Sep-2125-Oct-21GMP.1000Develop GMP3826-Oct-2121-Dec-21A1040F&F Building A & D Permit Cycle 12013-Dec-2111-Jan-22A1060F&F Building C Permit Cycle 12013-Dec-2111-Jan-22A1100Duke Energy Underground Duct Bank on Private Drive3013-Dec-2125-Jan-22GMP.2000Approve GMP522-Dec-2129-Dec-21A1050F&F Building A & D Permit Cycle 22025-Jan-2221-Feb-22A1090F&F Building C Permit Cycle 22025-Jan-2221-Feb-22MS.3000Notice to Proceed Construction021-Feb-22A1070Building Permit A & D4522-Feb-2225-Apr-22A1080Building Permit C4522-Feb-2225-Apr-22WBS: MHOL-19-1.16 SHOP DRAWINGSWBS: MHOL-19-1.16 SHOP DRAWINGS5526-Oct-2117-Jan-22MAMJJASONDJFMAMJJASONDJFMAMJJASONDJFMAMJJASO2021202220232024Summary - Design & PermittingMobilize/ Start ConstructionOwOOPOTIA SubmissionDD Documents Progress Set less SpecsDesign Assist Constraints for Concrete Finalized100% DD Documents and SpecsRemaining Design Assist On-BoardDesign Assist Concrete On-Board100% DD Pricing Update Deliverable Submitted50% CD DevelopmentLand Development Submitted to CityLand Development Submitted to NCDOTEnclave Sanitary Sewer DOT Permit90% CD DevelopmentDevelop GMPF&F Building A & D Permit Cycle 1F&F Building C Permit Cycle 1Duke Energy Underground Duct Bank on Private DriveApprove GMPF&F Building A & D Permit Cycle 2F&F Building C Permit Cycle 2Notice to Proceed ConstructionBuilding Permit A & DBuilding Permit CMHOL-19-1Finish Date: 19-Sep-24Data Date: 15-Apr-21Run Date: 17-Aug-21 13:52Page 1 of 3Remaining Level of EffortActual Level of EffortProject Baseline BarActual WorkRemaining WorkCritical Remaining WorkPrimary BaselineSecondary BaselineSummary MilestonesCritical MilestonesMorehead Overlook - 19.1 - Comfortable Case Schedule 7-30-21 - Draft
Activity IDActivity NameRemDurStartFinishCommentsWBS: MHOL-19-1.17 FAB & DELIVERWBS: MHOL-19-1.17 FAB & DELIVER2024-Nov-2123-Dec-21WBS: MHOL-19-1.18 SITE CONSTRUCTIONWBS: MHOL-19-1.18 SITE CONSTRUCTION44122-Feb-2216-Nov-23SITE.C.1140Excavate Vault - Building C1029-Mar-2211-Apr-22SITE.C.1150Set Precast Retention Vaults - Building C1012-Apr-2225-Apr-22SITE.C.1160Back Fill Vaults - Building C1026-Apr-2209-May-22WBS: MHOL-19-1.18.1 SITE ACTIVITIESWBS: MHOL-19-1.18.1 SITE ACTIVITIES44122-Feb-2216-Nov-23SITE.C.1000Mobilize on Site - Building C522-Feb-22*28-Feb-22SITE.C.1010Implement Pedestrian Route and Signage - Building C1001-Mar-2214-Mar-22SITE.C.1020Site Fencing and Lane Closure Barriers - Building C1015-Mar-2228-Mar-22SITE.C.1030Construction Office Set-up - Building C1029-Mar-2211-Apr-22SITE.C.1040Site Temp Power - Building C1029-Mar-2211-Apr-22SITE.C.1050Site Utility Cut Offs - Building C2029-Mar-2225-Apr-22SITE.C.1060Site Demo and Off-haul - Building C1029-Mar-2211-Apr-22SITE.C.1070Install Telecom into Building - Building C2012-Apr-2209-May-22SITE.C.1080Install Water Services - Building C2012-Apr-2209-May-22SITE.C.1090Install Storm Piping - Building C2012-Apr-2209-May-22SITE.C.1100Develop Staging and Access Areas - Building C1012-Apr-2225-Apr-22SITE.C.1110Pool/Patio Terrace Construction - Building C7507-Jul-2220-Oct-22SITE.C.1120Hardscape and Planting - Building C3528-Sep-2316-Nov-23SITE.C.1130Curb Gutter and Site Paving - Building C3028-Sep-2308-Nov-23WBS: MHOL-19-1.18.2 SITE WORKWBS: MHOL-19-1.18.2 SITE WORK7022-Feb-2231-May-22SITE.A.1020Mobilize - Building A&D1022-Feb-2207-Mar-22SITE.A.1040Install Tree Protection - Building A&D222-Feb-2223-Feb-22SITE.A.1050Close Euclid Ave - Building A&D522-Feb-2228-Feb-22SITE.A.1060Install Fencing - Building A&D522-Feb-2228-Feb-22SITE.A.1070Install Erosion Control - Building A&D522-Feb-2228-Feb-22SITE.A.1080Install Temporary Construction Entrance - Building A&D522-Feb-2228-Feb-22SITE.A.1090Install Temporary Drain Swales - Building A&D501-Mar-2207-Mar-22SITE.A.1100Mass Excavation - Building A&D1008-Mar-2221-Mar-22SITE.A.1120Set Precast Retention Vaults - Building A&D1022-Mar-2204-Apr-22SITE.A.1140Backfill Vaults - Building A&D1005-Apr-2218-Apr-22SITE.A.1160Install Temporary Roadways - Building A&D1019-Apr-2202-May-22SITE.A.1170Install Site Storm System - Building A&D1019-Apr-2202-May-22SITE.A.1180Install Sewer System - Building A&D1003-May-2216-May-22SITE.A.1190Install Site Water & Gas - Building A&D1017-May-2231-May-22WBS: MHOL-19-1.18.6 A&D - UNDERGROUND & SOGWBS: MHOL-19-1.18.6 A&D - UNDERGROUND & SOG7022-Mar-2228-Jun-22MAMJJASONDJFMAMJJASONDJFMAMJJASONDJFMAMJJASO2021202220232024Excavate Vault - Building CSet Precast Retention Vaults - Building CBack Fill Vaults - Building CMobilize on Site - Building CImplement Pedestrian Route and Signage - Building CSite Fencing and Lane Closure Barriers - Building CConstruction Office Set-up - Building CSite Temp Power - Building CSite Utility Cut Offs - Building CSite Demo and Off-haul - Building CInstall Telecom into Building - Building CInstall Water Services - Building CInstall Storm Piping - Building CDevelop Staging and Access Areas - Building CPool/Patio Terrace Construction - Building CHardscape and PlanCurb Gutter and Site Mobilize - Building A&DInstall Tree Protection - Building A&DClose Euclid Ave - Building A&DInstall Fencing - Building A&DInstall Erosion Control - Building A&DInstall Temporary Construction Entrance - Building A&DInstall Temporary Drain Swales - Building A&DMass Excavation - Building A&DSet Precast Retention Vaults - Building A&DBackfill Vaults - Building A&DInstall Temporary Roadways - Building A&DInstall Site Storm System - Building A&DInstall Sewer System - Building A&DInstall Site Water & Gas - Building A&DMHOL-19-1Finish Date: 19-Sep-24Data Date: 15-Apr-21Run Date: 17-Aug-21 13:52Page 2 of 3Remaining Level of EffortActual Level of EffortProject Baseline BarActual WorkRemaining WorkCritical Remaining WorkPrimary BaselineSecondary BaselineSummary MilestonesCritical MilestonesMorehead Overlook - 19.1 - Comfortable Case Schedule 7-30-21 - Draft
Activity IDActivity NameRemDurStartFinishCommentsUG.A.1000Deep Foundations3522-Mar-2209-May-22UG.A.1010Elevator Pits & Utilities1010-May-2223-May-22UG.A.1020Water Proof & Backfill524-May-2231-May-22UG.A.1040Grade Beams & Caps - Level 011001-Jun-2214-Jun-22TS.01.1000SOG - Level 011015-Jun-2228-Jun-22WBS: MHOL-19-1.A&D A&D - BUILDING A&DWBS: MHOL-19-1.A&D A&D - BUILDING A&D58401-Jun-2219-Sep-24WBS: MHOL-19-1.B B - BUILDINGWBS: MHOL-19-1.B B - BUILDING41912-Sep-2207-May-24WBS: MHOL-19-1.21 C - BUILDINGWBS: MHOL-19-1.21 C - BUILDING41626-Apr-2218-Dec-23MAMJJASONDJFMAMJJASONDJFMAMJJASONDJFMAMJJASO2021202220232024Deep FoundationsElevator Pits & UtilitiesWater Proof & BackfillGrade Beams & Caps - Level 01SOG - Level 01MHOL-19-1Finish Date: 19-Sep-24Data Date: 15-Apr-21Run Date: 17-Aug-21 13:52Page 3 of 3Remaining Level of EffortActual Level of EffortProject Baseline BarActual WorkRemaining WorkCritical Remaining WorkPrimary BaselineSecondary BaselineSummary MilestonesCritical MilestonesMorehead Overlook - 19.1 - Comfortable Case Schedule 7-30-21 - Draft
Sample ID: B-6 (MW-6) B-7 B-8 (MW-7) B-11 (MW-10) P-2 P-4
Sample Interval (ft bgs): 19-21 24-26 9-11 14-16 4-8 12-16 12-16 8-12 12-16 12-16
Sample Date: 2/26/1996 2/26/1996 2/26/1996 2/26/1996 9/28/2000 9/28/2000 9/28/2000 9/28/2000 9/28/2000 9/28/2000
Gasoline Range Organics ND ND ND ND NS NS NS NS NS NS NE NE NE
MADEP VPH
C5-C8 Aliphatics NS NS NS NS ND ND 120 ND ND ND NE NE NE
C9-C12 Aliphatics NS NS NS NS ND 31 1,300 39 95 240 NE NE NE
C9-C22 Aromatics NS NS NS NS ND ND 250 ND ND 53 NE NE NE
Residential
PSRGs
Non-Residential
PSRGs
Total Petroleum Hydrocarbons (TPH)
PoG PSRG
Volatile Organic Compounds by EPA Method 8260
P-1 P-3
Benzene NS NS NS NS ND ND ND ND ND ND 0.01 1.2 5.4
Toluene NS NS NS NS ND 0.4 ND ND 0.049 ND 8.3 990 9,700
Ethylbenzene NS NS NS NS ND 0.64 ND ND 0.056 0.048 13 6.1 27
Xylenes NS NS NS NS ND 3.2 ND ND 0.31 0.251 9.8 120 500
Isopropylbenzene NS NS NS NS ND 0.19 ND ND ND 0.036 2.3 410.0 2,100
n-Propylbenzene NS NS NS NS ND 0.73 ND ND 0.048 0.16 2.6 780.0 5,100
1,2,4-Trimethylbenzene NS NS NS NS 0.031 4.5 9.1 0.028 0.38 1.1 12 63 370
1,3,5-Trimethylbenzene NS NS NS NS ND 1.3 2.6 0.0063 0.096 0.33 11 56 320
n-Butylbenzene NS NS NS NS ND 0.44 0.77 ND ND 0.13 4.5 780 12,000
sec-Butylbenzene NS NS NS NS ND 0.15 ND ND ND 0.045 4.1 1,600 23,000
tert-Butylbenzene NS NS NS NS ND ND 0.61 ND ND ND 3.1 1,600 23,000
p-Isopropyltoluene NS NS NS NS ND 0.081 0.15 ND ND ND NE NE NE
Naphthalene NS NS NS NS ND 1.0 2.1 0.0066 0.14 0.38 0.39 2.1 8.8
Methylene Chloride NS NS NS NS 0.0091 ND ND ND ND ND 0.025 58 650
Acetone NS NS NS NS ND ND ND ND ND ND 25 12000 250,000
Notes:
Results are shown in milligrams per kilogram (mg/kg).
ft bgs - Feet Below Ground Surface
ppm - parts per million
Only compounds detected within one or more sample are shown except for TPH- Gasoline Range Organics
NA - Not Analyzed
ND - Not Detected above laboratory method detection limit
NE - Not Established
Detections are indicated in bold.
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
PSRG - NCDEQ Inactive Hazardous Sites Branch Preliminary Soil Remediation Goals (July 2020)
Shaded cells indicate the detected concentrations exceed the regulatory threshold of the corresponding color.
Table 1
Summary of Historical Soil Analytical Results (Pre-2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina
Terracon Project No.71197661
Sample ID: P-6 P-7 P-9
Sample Interval (ft bgs): 8-12 12-16 8-12 8-12 12-16 13.5-15 16-17.5 16-17.5 18.5-20
Sample Date: 9/28/2000 9/28/2000 9/28/2000 9/28/2000 9/28/2000 6/29/2005 6/29/2005 6/29/2005 6/29/2005
Gasoline Range Organics NS NS NS NS NS NS NS NS NS NE NE NE
MADEP VPH
C5-C8 Aliphatics ND 21 ND ND ND 0.78 J 0.56 J ND 1.0 J NE NE NE
C9-C12 Aliphatics ND 99 ND ND 59 ND ND ND ND NE NE NE
C9-C22 Aromatics ND 21 ND ND 12 1.5 3.2 ND 2.6 NE NE NE
Benzene ND 0.0063 ND ND ND 0.0053 0.003 J ND ND 0.01 1.2 5.4
Toluene ND 0.0064 ND ND 0.27 0.017 0.0093 0.00074 J 0.0025 J 8.3 990 9,700
Ethylbenzene ND 0.014 ND ND 0.62 0.011 0.018 0.00071 0.0014 13 6.1 27
Xylenes 0.032 0.09 ND ND 2.92 0.041 0.051 0.003 J 0.007 J 9.8 120 500
Isopropylbenzene ND 0.0078 ND ND 0.22 NS NS NS NS 2.3 410.0 2,100
n-Propylbenzene ND 0.031 ND ND 0.79 NS NS NS NS 2.6 780.0 5,100
1,2,4-Trimethylbenzene ND 0.25 ND ND 2.6 NS NS NS NS 12 63 370
1,3,5-Trimethylbenzene 0.033 0.077 ND ND 1.3 NS NS NS NS 11 56 320
n-Butylbenzene ND 0.043 ND ND 0.47 NS NS NS NS 4.5 780 12,000
sec-Butylbenzene ND 0.011 ND ND 0.18 NS NS NS NS 4.1 1,600 23,000
tert-Butylbenzene ND ND ND ND ND NS NS NS NS 3.1 1,600 23,000
p-Isopropyltoluene ND 0.0073 ND ND 0.094 NS NS NS NS NE NE NE
Naphthalene ND 0.12 ND ND 1.1 0.0038 J 0.0068 ND 0.0014 J 0.39 2.1 8.8
Methylene Chloride ND ND ND ND ND NS NS NS NS 0.025 58 650
Acetone ND ND ND ND ND ND ND ND ND 25 12000 250,000
Notes:
Results are shown in milligrams per kilogram (mg/kg).
ft bgs - Feet Below Ground Surface
ppm - parts per million
Only compounds detected within one or more sample are shown except for TPH- Gasoline Range Organics
NA - Not Analyzed
ND - Not Detected above laboratory method detection limit
NE - Not Established
Detections are indicated in bold.
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
PSRG - NCDEQ Inactive Hazardous Sites Branch Preliminary Soil Remediation Goals (July 2020)
Shaded cells indicate the detected concentrations exceed the regulatory threshold of the corresponding color.
Total Petroleum Hydrocarbons (TPH)
Volatile Organic Compounds by EPA Method 8260
P-5 B-8 (MW-1)B-9 (MW-2)
PoG PSRG Residential
PSRGs
Non-Residential
PSRGs
Table 1
Summary of Historical Soil Analytical Results (Pre-2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina
Terracon Project No.71197661
Sample ID: GP-7
Sample Interval (ft bgs): 13.5-15 16-17.5 16-17.5 18.5-20 16-18 10-12 14-16 8-10 11-13
Sample Date: 6/29/2005 6/29/2005 6/29/2005 6/29/2005 1/21/2014 1/21/2014 1/21/2014 1/21/2014 1/21/2014
Gasoline Range Organics NS NS NS NS NS NS NS NS NS NE NE NE
MADEP VPH
C5-C8 Aliphatics ND ND 0.79 J 0.69 J ND ND ND ND 32 NE NE NE
C9-C12 Aliphatics ND ND ND ND ND ND ND ND ND NE NE NE
C9-C22 Aromatics 0.31 ND 0.69 J 0.69 J ND ND 17 ND 62 NE NE NE
Benzene ND ND ND ND ND ND ND ND ND 0.01 1.2 5.4
Toluene 0.0012 J 0.00054 J 0.00075 J 0.0024 J ND ND ND ND ND 8.3 990 9,700
Ethylbenzene 0.00078 J 0.0005 J 0.00075J 0.0012 J ND ND 0.019 ND 16 13 6.1 27
Xylenes 0.0049 J 0.0031 J 0.004 J 0.0068 J ND ND 0.10 ND 37 9.8 120 500
Isopropylbenzene NS NS NS NS ND ND 0.020 ND 6.5 2.3 410 2,100
n-Propylbenzene NS NS NS NS ND ND ND ND 29 2.6 780 5,100
1,2,4-Trimethylbenzene NS NS NS NS ND ND 0.22 ND 110 12 63 370
1,3,5-Trimethylbenzene NS NS NS NS ND ND 0.057 ND 35 11 56 320
n-Butylbenzene NS NS NS NS ND ND 0.096 ND 19 4.5 780 12,000
sec-Butylbenzene NS NS NS NS ND ND 0.022 ND 5.0 4.1 1,600 23,000
tert-Butylbenzene NS NS NS NS ND ND ND ND ND 3.1 1,600 23,000
p-Isopropyltoluene NS NS NS NS ND ND 0.013 ND 2.5 NE NE NE
Naphthalene ND ND ND ND ND ND ND ND 18 0.39 2.1 8.8
Methylene Chloride NS NS NS NS 0.0061 0.0079 ND ND ND 0.025 58 650
Acetone ND ND ND ND ND 0.019 ND ND ND 25 12000 250,000
Notes:
Results are shown in milligrams per kilogram (mg/kg).
ft bgs - Feet Below Ground Surface
ppm - parts per million
Only compounds detected within one or more sample are shown except for TPH- Gasoline Range Organics
NA - Not Analyzed
ND - Not Detected above laboratory method detection limit
NE - Not Established
Detections are indicated in bold.
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
PSRG - NCDEQ Inactive Hazardous Sites Branch Preliminary Soil Remediation Goals (July 2020)
Shaded cells indicate the detected concentrations exceed the regulatory threshold of the corresponding color.
Non-Residential
PSRGs
Total Petroleum Hydrocarbons (TPH)
Volatile Organic Compounds by EPA Method 8260
B-10 (MW-4)B-5 (MW-3)GP-8 GP-9
PoG PSRG Residential
PSRGs
Table 1
Summary of Historical Soil Analytical Results (Pre-2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina
Terracon Project No.71197661
Sample ID:
Sample Date:3/1/1996 5/19/2000 1/2/2004 10/12/2005 1/26/2012 4/5/2012 1/17/2014 7/21/2014 3/1/1996 5/19/2000 3/22/1996 5/19/2000 6/30/2005
C5-C8 Aliphatics NA NA 8,700 20,000 NA 10,100 11,000 6,000 NA NA NA NA ND 400 NE NE NE
C9-C18 Aliphatics NA NA 1,100 7,800 NA 2,550 NA 1,300 NA NA NA NA ND 700 NE NE NE
C9-C22 Aromatics NA NA 5,500 8,100 NA 5,340 4,600 4,300 NA NA NA NA ND 200 NE NE NE
Benzene 1,800 600 280 170 38.6 NA 25 80 ND ND ND ND ND 1 5,000 16 69
Toluene 8,700 1,800 2,000 2,300 197 NA 240 1,300 ND ND ND ND ND 600 260,000 3,800 16,000
Ethylbenzene 2,400 1,100 1,100 1,600 402 NA 370 1,500 ND ND ND ND ND 600 84,500 35 150
Xylene 7,200 2,000 2,900 3,800 856 NA 1,090 5,700 ND ND ND ND 0.59 J 500 85,500 77 320
MTBE 120 ND ND ND ND NA ND ND 2.8 ND ND ND 140 20 20,000 4,500 2,000
IPE ND 340 ND NA ND NA ND ND ND ND ND ND NA 70 70,000 1,400 5,900
EDB 0.022 ND ND NA ND NA ND ND ND ND ND ND NA 0.02 50 1.8 7.7
Chloroform NA NA NA NA ND NA ND ND ND ND ND ND NA 70 70,000 8.1 36
Trichloroethene ND ND NA NA ND NA ND ND ND ND ND ND NA 3 3,000 1.0 4.4
Naphthalene 270 NA NA NA 210 NA 98 310 ND NA NA NA 1.3 J 6 6,000 35 150
Isopropylbenzene NA NA NA NA 53.3 NA 45 73 NA NA NA NA NA 70 25,000 180 750
p-Isopropyltoluene NA NA NA NA ND NA 8.4 8.0 NA NA NA NA NA 25 11,700 NE NE
2-Butanone NA NA NA NA ND NA ND ND NA NA NA NA NA 4,000 4,000,000 450,000 1,900,000
n-Butylbenzene NA NA NA NA ND NA 43 20 NA NA NA NA NA 70 6,900 NE NE
sec-Butylbenzene NA NA NA NA ND NA 14 12 NA NA NA NA NA 70 8,500 NE NE
tert-Butylbenzene NA NA NA NA ND NA NA NA NA NA NA NA NA 70 15,000 NE NE
n-Propylbenzene NA NA NA NA 86.7 NA 98 160 NA NA NA NA NA 70 30,000 490 2,000
1,2,4-Trimethylbenzene NA NA NA NA 337 NA 620 1,700 NA NA NA NA NA 400 28,500 50 210
1,3,5-Trimethylbenzene NA NA NA NA 96.9 NA 200 460 NA NA NA NA NA 400 25,000 35 150
Bis(2-ethylhexyl)phthalate ND NA NA NA NA NA NA NA 4.3 NA NA NA NA 3 170 NE NE
Phenol ND NA NA NA NA NA NA NA 1.6 NA NA NA NA 30 30,000 NE NE
Lead 0.0093 J ND NA NA NA ND 4.5 ND 0.0089 J ND ND ND NA 15 15,000 NE NE
Notes:
Data obtained from the following prior reports prepared by others: LAW Engineering Comprehensive Site Assessment (1996); LAW Report of Groundwater Monitoring (2000); ECS Assessment of Petroleum Impacted Soils (2000); S&ME Soil and Groundwater Assessment Report (2004);
Schnabel Environmental Assessment (2004); Hart & Hickman Pre-CAP Monitoring Plan (2014); and Hart & Hickmman Groundwater Monitoring Report (2014).
NA - Not Analyzed
ND - Not Detected above laboratory method detection limits
NE - Not Established
All results are shown in micrograms per liter (µg/L).
Only compounds detected in one or more sample are shown.
Detections are indicated in bold.
J - Estimated concentration between method detection limit and reporting limit.
Concentrations highlighted in yellow exceed their respective NCDEQ 2L groundwater standards (or Interim Maximum Contaminant Levels if a 2L standard has not been established).
Concentrations highlighted in orange exceed their respective Gross Contaminant Levels.
Concentrations shaded in green exceed their respective NCDEQ Residential Groundwater Screening Levels for Vapor Intrusion (February 2018).
Concentrations shaded in blue exceed their respective NCDEQ Non-Residential Groundwater Screening Levels for Vapor Intrusion (February 2018).
In cases where a concentration exceeds multiple standards, the shading for the exceedance of a vapor standard is given preference.
Gross
Contaminant Level
VI-GWSL
Residential
VI-GWSL Non-
Residential
NCDEQ 2L
Groundwater
Standard
Analyte
Semi-Volatile Organic Compounds by EPA Method 8270
MADEP VPH
Lead by EPA Method 6010
Volatile Organic Compounds by EPA Method 8260, 601/602, and/or 504-1
MW-7 MW-10MW-6
Table 2
Summary of Historical Groundwater Analytical Results (Pre-2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina Terracon Project No.
71197661
Table 2
Summary of Historical Groundwater Analytical Results (Pre-2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina Terracon Project No.
71197661
Sample ID:MW-11 TW-1 (P-2)*TW-2 (P-10)MW-2 MW-3 MW-4 HTTW-4 HTTW-5
Sample Date:10/5/2000 10/5/2000 10/5/2000 6/30/2005 6/30/2005 6/30/2005 1/22/2014 1/22/2014
MADEP VPH
C5-C8 Aliphatics ND 3,700 6,200 ND ND ND 620 66 400 NE NE NE
C9-C18 Aliphatics ND 26,000 42,000 ND ND ND 71 100 700 NE NE NE
C9-C22 Aromatics ND 2,400 3,900 ND ND ND 720 75 200 NE NE NE
Volatile Organic Compounds by EPA Method 8260, 601/602, and/or 504-1
Benzene ND ND 16,000 190 1.2 NA 6.6 ND 1 5,000 16 69
Toluene ND ND 77,000 1,300 NA 0.26 J 0.82 ND 600 260,000 3,800 16,000
Ethylbenzene ND ND 25,000 1,800 NA NA 4.3 ND 600 84,500 35 150
Xylene ND ND 121,000 7,400 NA 0.41 J 2 ND 500 85,500 77 320
MTBE ND ND ND ND ND 4.5 J ND 1.9 20 20,000 4,500 2,000
IPE ND ND ND NA NA NA 8.5 ND 70 70,000 1,400 5,900
EDB NA NA NA NA NA NA ND 0.033 0.02 50 1.8 7.7
Chloroform ND 5.3 ND NA NA NA 0.29 1.7 70 70,000 8.1 36
Trichloroethene ND ND ND NA NA NA ND 1.1 3 3,000 1.0 4.4
Naphthalene NA NA NA 730 2.9 ND 2.7 ND 6 6,000 35 150
Isopropylbenzene NA NA NA NA NA NA ND ND 70 25,000 180 750
p-Isopropyltoluene NA NA NA NA NA NA ND ND 25 11,700 NE NE
2-Butanone NA NA NA NA NA NA 6.1 ND 4,000 4,000,000 450,000 1,900,000
n-Butylbenzene NA NA NA NA NA NA 2.9 ND 70 6,900 NE NE
sec-Butylbenzene NA NA NA NA NA NA 3.5 ND 70 8,500 NE NE
tert-Butylbenzene NA NA NA NA NA NA 0.3 ND 70 15,000 NE NE
n-Propylbenzene NA NA NA NA NA NA 1.8 ND 70 30,000 490 2,000
1,2,4-Trimethylbenzene NA NA NA NA NA NA 1.5 ND 400 28,500 50 210
1,3,5-Trimethylbenzene NA NA NA NA NA NA 0.44 ND 400 25,000 35 150
Semi-Volatile Organic Compounds by EPA Method 8270
Bis(2-ethylhexyl)phthalate NA NA NA NA NA NA NA NA 3 170 NE NE
Phenol NA NA NA NA NA NA NA NA 30 30,000 NE NE
Lead by EPA Method 6010
Lead NA NA NA NA NA NA 5.5 34 15 15,000 NE NE
Notes:
Data obtained from the following prior reports prepared by others: LAW Engineering Comprehensive Site Assessment (1996); LAW Report of Groundwater Monitoring (2000); ECS Assessment of Petroleum Impacted Soils (2000); S&ME Soil and Groundwater Assessment Report (2004);
Schnabel Environmental Assessment (2004); Hart & Hickman Pre-CAP Monitoring Plan (2014); and Hart & Hickmman Groundwater Monitoring Report (2014).
NA - Not Analyzed
ND - Not Detected above laboratory method detection limits
NE - Not Established
All results are shown in micrograms per liter (µg/L).
Only compounds detected in one or more sample are shown.
Detections are indicated in bold.
J - Estimated concentration between method detection limit and reporting limit.
Concentrations highlighted in yellow exceed their respective NCDEQ 2L groundwater standards (or Interim Maximum Contaminant Levels if a 2L standard has not been established).
Concentrations highlighted in orange exceed their respective Gross Contaminant Levels.
Concentrations shaded in green exceed their respective NCDEQ Residential Groundwater Screening Levels for Vapor Intrusion (February 2018).
Concentrations shaded in blue exceed their respective NCDEQ Non-Residential Groundwater Screening Levels for Vapor Intrusion (February 2018).
In cases where a concentration exceeds multiple standards, the shading for the exceedance of a vapor standard is given preference.
Analyte
NCDEQ 2L
Groundwater
Standard
Gross
Contaminant Level
VI-GWSL
Residential
VI-GWSL Non-
Residential
Sample ID:S-1 S-2 S-3 S-4 BG-1 BG-2
Sample Date:02/21/20 02/21/20 02/21/20 02/21/20 02/21/20 02/21/20
Sample Interval
(ft bgs):10-15 10-14 5-10 0-5
25 12,000 140,000 0.0108J 0.0128J 0.019J <0.0069 NA NA
4.5 780 12,000 0.0124 <0.0022 <0.0023 <0.0021 NA NA
4.1 1,600 23,000 0.0026J <0.0017 <0.0017 <0.0016 NA NA
2.3 410 2,100 0.0013J <0.0011 <0.0012 <0.0011 NA NA
1.24 NS NS 0.0059 <0.0019 <0.002 <0.0018 NA NA
0.39 4.1 18 0.027 <0.0033 <00034 <0.0031 NA NA
2.6 780 5,100 0.0058 <0.0013 <0.0014 <0.0012 NA NA
12 63 370 0.052 <0.0015 <0.0016 <0.0014 NA NA
11 56 320 0.0131 <0.0013 <0.0014 <0.0012 NA NA
9.9 120 530 0.0021J <0.0027 <0.0028 <0.0026 NA NA
5.8 0.68 3 0.67J 1.4 2.2 0.72 2.6 1.3
580 3,100 47,000 194 18.2 30 65.7 113 31
360,000 23,000 350,000 22.3 7.6 104 42 19.8 5.9
270 400 800 2.1 2 6.3 2.3 7.2 7.1
1 2.3 9.7 <0.0027 0.008 0.043 0.011 0.015 0.043
Notes:
All results are shown in milligrams per kilogram (mg/kg).
ft bgs - Feet Below Ground Surface
NS - No Standard
ND - Not detected
NA- Not analyzed
J - estimated concentration above the method detection limit but below the laboratory reporting limit
Total chromium is assumed to consist exclusively of trivalent chromium since hexavalent chromium was not detected in the soils.
PSRG - NCDEQ Inactive Hazardous Sites Branch Preliminary Soil Remediation Goals, updated December, 2019.
Concentrations highlighted in yellow exceed their respective residential PSRG.
Concentrations highlighted in orange exceed their respective non-residential PSRG.
No semi-volatile organic compounds were detected.
Semi-Volatile Organic Compounds by EPA Method 8270
Naphthalene
n-Propylbenzene
1,2,4-Trimethylbenzene
1,3,5-Trimethylbenzene
Total Xylenes
Volatile Organic Compounds by EPA Method 8260
Analyte
Acetone
Mercury
RCRA Metals by EPA Method 6010, 7196, and 7471
Arsenic
Barium
Chromium
Lead
Residential
PSRGs
Non-
Residential
PSRGs
Protection of
Groundwater
PSRGs
n-Butylbenzene
sec-Butylbenzene
Isopropylbenzene (Cumene)
p-Isopropyltoluene
Table 3
Summary of Historical Soil Analytical Results (2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina
Terracon Project No.71197661
Sample ID:TW-2 TW-3 TW-4
Sample Date:02/21/20 2/21/2020 2/21/2020
Screen Interval (ft bgs):9-24 16-31 25-40
Benzene 1 45.1 <0.15 <0.15
Diisopropyl ether 70 <1.1 <0.22 0.22J
Ethylbenzene 600 636 <0.26 <0.26
p-Isopropyltoluene 25 17.5 <0.21 <0.21
Methyl tert-butyl ether 20 <1.4 0.31J 0.31J
Naphthalene 6 186 0.65J <0.35
Toluene 600 421 <0.24 <0.24
Total Xylenes 500 810 1.7 <0.63
Benzo(a)anthracene 0.05 <1.5 <1.5 3.7J
Benzo(a)pyrene 0.005 <1.8 <1.8 4.1J
Benzo(b)fluoranthene 0.05 <1.7 <1.7 3.8J
Benzo(g,h,i)perylene 200 <1.6 <1.6 4.7J
Benzo(k)fluoranthene 0.5 <1.5 <1.5 4.2J
Butylbenzylphthalate 1000 <1.9 <1.9 3.8J
Chrysene 5 <1.4 <1.4 4.2J
Dibenz(a,h)anthracene 0.005 <1.6 <1.6 4.5J
Di-n-butylphthalate 700 <1.6 <1.6 2.9J
Di-n-octylphthalate 100 <2.2 <2.2 4.6J
bis(2-Ethylhexyl)phthalate 3 <2.0 <2.0 4.6J
Fluoranthene 300 <1.6 <1.6 2.7J
Hexachlorobenzene 0.02 <1.3 <1.3 1.4J
Indeno(1,2,3-cd)pyrene 0.05 <1.7 <1.7 4.5J
1-Methylnaphthalene 1 16.5 <1.4 <1.4
2-Methylnaphthalene 30 24 <1.4 <1.4
Naphthalene 6 63 <1.6 <1.6
Phenanthrene 200 <1.4 <1.4 1.6J
Pyrene 200 <1.5 <1.5 2.8J
Barium 700 92.9 133 66.7
Lead 15 <1.6 1.8J <1.6
Notes:
Concentrations are reported in micrograms per liter (µg/L).
Only detected compounds are shown.
J - estimated concentration above the method detection limit but below the laboratory reporting limit
NCAC 2L GWQS - North Carolina Administrative Code Subchapter 2L Groundwater Quality Standards (April 1, 2013).
Concentrations highlighted in yellow exceed their respective NCAC 2L GWQS
RCRA Metals by EPA Method 6010
Mercury not detected in any of the samples.
Analyte NCAC 2L
GWQS
Volatile Organic Compounds by EPA Method 8260
Mercury by EPA Method 7470
Semi-Volatile Organic Compounds by EPA Method 8270
Table 4
Summary of Historical Groundwater Analytical Results (2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina Terracon
Project No. 71197661
Sample ID:SV-01 SV-02 DUP-01
(SV-02)SV-03 SV-04 SV-05
Sample Depth:4.5-5 3-3.5 3-4 4.75-5.25 4.5-5 4.5-5
Helium NS <0.1 %NS NS NS NS NE NE
12.6 6.56 6.2 6.68 60.6 7.51 220,000 2,700,000
Benzene <0.639 <0.639 <0.639 <0.639 3.51 <0.639 120 1,600
Carbon Disulfide 11.2 <0.622 <0.622 13.4 220 16.8 4,900 61,000
Chloroform <0.973 1.24 0.988 1.02 8.37 1.14 8.1 530
Chloromethane 0.551 <0.413 0.477 <0.413 6.92 1.13 630 7,900
Cyclohexane <0.689 <0.689 <0.689 <0.689 1.17 <0.689 42,000 530,000
1,3-Dichlorobenzene 3.23 5.31 3.14 6.13 <1.20 6.43 NE NE
Ethanol 82.8 45.6 49.4 25.8 21.7 39 NE NE
Ethylbenzene <0.867 <0.867 <0.867 1.19 8.71 <0.867 370 4,900
4-Ethyltoluene <0.982 <0.982 <0.982 1.65 9.91 <0.982 NE NE
Trichlorofluoromethane (Freon 11)<1.12 1.12 1.16 1.54 1.78 8.04 NE NE
Dichlorodifluoromethane (Freon 12)1.61 1.67 1.77 1.69 2.03 4.64 700 8,800
Heptane <0.818 <0.818 <0.818 <0.818 3.19 <0.818 2,800 35,000
Hexane <0.705 <0.705 <0.705 <0.705 2.98 <0.705 4,900 61,000
Methyl Ethyl Ketone (2-Butanone)<3.69 <3.69 <3.69 <3.69 8.14 <3.69 35,000 440,000
Methyl tert-Butyl Ether (MTBE)<0.721 <0.721 <0.721 <0.721 3.96 <0.721 3,600 47,000
Methylene Chloride 1.26 <0.694 0.802 <0.694 <0.694 <0.694 4,200 1,800,000
2-Propanol 5.73 4.52 <3.07 18.2 4.62 4.01 1,400 18,000
Tetrachloroethylene <1.36 <1.36 3.93 <1.36 <1.36 <1.36 280 3,500
Tetrahydrofuran 2.59 4.19 2.95 3.89 50.1 2.06 14,000 180,000
Toluene 2.99 <0.753 1.14 4.11 32.8 1.23 35,000 440,000
1,2,4-Trimethylbenzene 2.02 <0.982 <0.982 2.54 13.3 <0.982 420 5,300
1,3,5-Trimethylbenzene <0.982 <0.982 <0.982 <0.982 3.57 <0.982 420 5,300
2,2,4-Trimethylpentane <0.934 <0.934 <0.934 <0.934 1 <0.934 NE NE
m&p-xylene 2.25 <1.73 <1.73 4.81 33.9 <1.73 700 8,800
o-Xylene 1.28 <0.867 <0.867 1.94 12.1 <0.867 700 8,800
Notes:
Vapor samples were collected on Apri 14, 2020.
Concentrations are reported in micrograms per cubic meter (μg/m3) unless otherwise noted.
Only compounds detected in one or more samples are shown.
Concentrations detected above the laboratory reporting limit are shown in bold.
NS - Not Sampled/Analyzed
NE - Not Established
DWM - North Carolina Department of Environmental Quality, Division of Waste Management
SGSL - DWM Sub-slab and Exterior Soil Gas Screening Level, updated February 2018.
Concentrations highlighted in yellow exceed their respective Residential SGSL.
Residential
SGSL Non-Residential SGSL
EPA Method 3C
EPA Method TO-15
Acetone
Table 5
Summary of Historical Soil Gas Analytical Results (2020)
Red Carpet Inn Brownfields Site
Brownfields Site No. 23070-19-060
615 East Morehead Street
Charlotte, Mecklenburg County, North Carolina Terracon
Project No. 71197661
Table 6
Summary of Historical Soil Vapor Analytical Results (2021)
Red Carpet Inn Brownfields Site
NCBP ID: 23070-19-060
615 E. Morehead Street
Charlotte, Mecklenburg County, North Carolina
Terracon Project No. 71197661
Sample ID: 2021-SV-01 2021-SV-02 (2021-SV-02)2021-SV-03 2021-SV-04 2021-SV-05
Sample Depth:7.5-8 7.5-8 7.5-8 5.25-5.75 7.5-8 7.5-8
Acetone 15 34 33 42 37 55 220,000 2,700,000
Benzene 0.58 5.5 5.6 4 4.2 11 12 160
2-Butanone (MEK)<0.98 6.4 J 6.3 J 7.3 J 5 J 9.5 J 35,000 440,000
Chloroform 0.28 J <0.12 <0.12 <0.12 <0.12 3.5 4.1 53
Ethanol 4.9 J 30 18 15 27 9.1 NE NE
Ethylbenzene 0.74 3.5 3.4 2.2 3.1 5 37 490
Heptane <0.18 46 41 2.6 19 37 2,800 35,000
Hexane <0.64 <0.64 <0.64 9.4 J 9.4 J 25 4,900 61,000
Isopropanol <2.3 6.4 J 7.2 J 7.9 J <2.3 6.1 J 1,400 18,000
Propene <0.58 30 <0.58 110 62 170 21,000 260,000
Styrene <0.12 0.36 J <0.12 1.1 0.6 1.9 7,000 88,000
Tetrachloroethylene 0.75 0.85 1.3 1.4 0.81 0.72 280 3,500
Toluene 190 140 110 220 70 84 35,000 440,000
Trichloroethylene <0.20 <0.20 <0.20 <0.20 1.3 <0.20 14 180
Trichlorofluoromethane (Freon 11)3.3 2.8 2.8 6.4 2.3 1.7 J NE NE
1,2,4-Trimethylbenzene <0.11 2.5 <0.11 <0.11 <0.11 2.4 420 5,300
1,3,5-Trimethylbenzene <0.13 0.65 <0.13 <0.13 0.51 0.64 420 5,300
m&p-Xylene 2.8 11 11 5.2 9.4 13 700 8,800
o-Xylene 0.84 4.4 4.2 2 3.7 5.5 700 8,800
Notes:
Vapor samples were collected on March 26, 2021.
Concentrations are reported in micrograms per cubic meter (μg/m3) unless otherwise noted.
Only compounds detected in one or more samples are shown.
Concentrations detected above the laboratory reporting limit are shown in bold.
J - Estimated concentration between laboratory method detection and reporting limits.
NE - Not Established
DWM - North Carolina Department of Environmental Quality, Division of Waste Management
SGSL - DWM Sub-slab and Exterior Soil Gas Screening Level, updated January 2021.
Concentrations highlighted in yellow exceed their respective Residential SGSL.
Residential
SGSL
Non-
Residential
SGSL
EPA Method TO-15
Version Date:
Basis:
Site Name:
Site Address:
DEQ Section:
Site ID:
Exposure Unit ID:
Submittal Date:
Reviewed By:
North Carolina Department of Environmental Quality
Risk Calculator
Red Carpet Inn Brownfields Site
615 East Morehead Street, Charlotte NC
NCBP
23070-19-060
December 2019
November 2019 EPA RSL Table
Prepared By:Terracon Consultants Inc
North Carolina DEQ Risk Calculator
Complete Exposure Pathways
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Note: Risk output will only be calculated for complete exposure pathways.
Receptor Pathway
Check box if
pathway
complete
Soil
Groundwater Use
Soil
Groundwater Use
Construction Worker Soil
Soil
Surface Water
Groundwater to Indoor Air
Soil Gas to Indoor Air
Indoor Air
Groundwater to Indoor Air
Soil Gas to Indoor Air
Indoor Air
Source Soil
Source Groundwater
Source Soil
Source Groundwater
Resident
Non-Residential Worker
CONTAMINANT MIGRATION PATHWAYS
Groundwater
Surface Water
Input Form 1A
VAPOR INTRUSION PATHWAYS
DIRECT CONTACT SOIL AND WATER PATHWAYS
Resident
Non-Residential Worker
Recreator/Trespasser
North Carolina DEQ Risk Calculator
Exposure Point Concentrations
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Exposure Point
Concentration
(mg/kg)
Notes:CAS Number Chemical
Minimum
Concentration
(Qualifier)
Maximum
Concentration
(Qualifier)
Units
Location of
Maximum
Concentration
Detection
Frequency
0.019 67-64-1 Acetone mg/kg
2.6 7440-38-2 Arsenic, Inorganic mg/kg
194 7440-39-3 Barium mg/kg
0.0124 104-51-8 Butylbenzene, n-mg/kg
0.0026 135-98-8 Butylbenzene, sec-mg/kg
104 16065-83-1 Chromium(III), Insoluble Salts mg/kg
0.0013 98-82-8 Cumene mg/kg
7.2 7439-92-1 ~Lead and Compounds mg/kg
0.043 7439-97-6 ~Mercury (elemental)mg/kg
0.027 91-20-3 ~Naphthalene mg/kg
0.0058 103-65-1 Propyl benzene mg/kg
0.052 95-63-6 Trimethylbenzene, 1,2,4-mg/kg
0.0131 108-67-8 Trimethylbenzene, 1,3,5-mg/kg
0.0021 1330-20-7 Xylenes mg/kg
Soil Exposure Point Concentration Table
Description of Exposure Point Concentration Selection:
North Carolina DEQ Risk Calculator
Range of
Detection Limits
Concentration
Used for
Screening
Background
Value
Screening
Toxicity Value
(Screening
Level) (n/c)
Potential
ARAR/TBC
Value
Potential
ARAR/TBC
Source
COPC
Flag
(Y/N)
Rationale for
Selection or
Deletion
Input Form 2A
North Carolina DEQ Risk Calculator
Exposure Point Concentrations
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Description of Exposure Point Concentration Selection:
Exposure Point
Concentration (ug/L)Notes:CAS Number Chemical
Minimum
Concentration
(Qualifier)
Maximum
Concentration
(Qualifier)
Units
Location of
Maximum
Concentration
Detection
Frequency
133 7440-39-3 Barium ug/L
45.1 71-43-2 Benzene ug/L
0.22 108-20-3 Diisopropyl Ether ug/L
636 100-41-4 Ethylbenzene ug/L
1.4 118-74-1 Hexachlorobenzene ug/L
1.8 7439-92-1 ~Lead and Compounds ug/L
0.31 1634-04-4 Methyl tert-Butyl Ether (MTBE)ug/L
4.6 117-81-7 ~Bis(2-ethylhexyl)phthalate ug/L
3.8 85-68-7 ~Butyl Benzyl Phthalate ug/L
2.9 84-74-2 ~Dibutyl Phthalate ug/L
4.6 117-84-0 ~Octyl Phthalate, di-N-ug/L
3.7 56-55-3 ~Benz[a]anthracene ug/L
4.1 50-32-8 ~Benzo[a]pyrene ug/L
3.8 205-99-2 ~Benzo[b]fluoranthene ug/L
4.2 207-08-9 ~Benzo[k]fluoranthene ug/L
4.2 218-01-9 ~Chrysene ug/L
4.5 53-70-3 ~Dibenz[a,h]anthracene ug/L
2.7 206-44-0 ~Fluoranthene ug/L
4.5 193-39-5 ~Indeno[1,2,3-cd]pyrene ug/L
16.5 90-12-0 ~Methylnaphthalene, 1-ug/L
24 91-57-6 ~Methylnaphthalene, 2-ug/L
186 91-20-3 ~Naphthalene ug/L
2.8 129-00-0 ~Pyrene ug/L
421 108-88-3 Toluene ug/L
810 1330-20-7 Xylenes ug/L
Groundwater Exposure Point Concentration Table
North Carolina DEQ Risk Calculator
Range of
Detection
Limits
Concentration
Used for
Screening
Background
Value
Screening
Toxicity Value
(Screening Level)
(n/c)
Potential
ARAR/TBC
Value
Potential
ARAR/TBC
Source
COPC
Flag
(Y/N)
Rationale for
Selection or Deletion
Input Form 2B
North Carolina DEQ Risk Calculator
Exposure Point Concentrations
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Description of Exposure Point Concentration Selection:
Note: Chemicals highlighted in orange are non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals.
Exposure Point
Concentration
(ug/m3)
Notes:CAS Number Chemical
Minimum
Concentration
(Qualifier)
Maximum
Concentration
(Qualifier)
Units
Location of
Maximum
Concentration
Detection
Frequency
60.6 67-64-1 Acetone ug/m3
3.51 71-43-2 Benzene ug/m3
220 75-15-0 Carbon Disulfide ug/m3
8.37 67-66-3 Chloroform ug/m3
6.92 74-87-3 Chloromethane ug/m3
1.17 110-82-7 Cyclohexane ug/m3
4.64 75-71-8 Dichlorodifluoromethane ug/m3
8.71 100-41-4 Ethylbenzene ug/m3
50.1 109-99-9 ~Tetrahydrofuran ug/m3
3.19 142-82-5 Heptane, N-ug/m3
2.98 110-54-3 Hexane, N-ug/m3
18.2 67-63-0 Isopropanol ug/m3
8.14 78-93-3 Methyl Ethyl Ketone (2-Butanone)ug/m3
3.96 1634-04-4 Methyl tert-Butyl Ether (MTBE)ug/m3
1.26 75-09-2 Methylene Chloride ug/m3
3.93 127-18-4 Tetrachloroethylene ug/m3
32.8 108-88-3 Toluene ug/m3
8.04 75-69-4 Trichlorofluoromethane ug/m3
13.3 95-63-6 Trimethylbenzene, 1,2,4-ug/m3
3.57 108-67-8 Trimethylbenzene, 1,3,5-ug/m3
1 25167-70-8 Trimethylpentene, 2,4,4-ug/m3
33.9 106-42-3 Xylene, P-ug/m3
33.9 108-38-3 Xylene, m-ug/m3
12.1 95-47-6 Xylene, o-ug/m3
Soil Gas Exposure Point Concentration Table
North Carolina DEQ Risk Calculator
Range of
Detection
Limits
Concentration
Used for
Screening
Background
Value
Screening
Toxicity Value
(Screening
Level) (n/c)
Potential
ARAR/TBC
Value
Potential
ARAR/TBC
Source
COPC Flag
(Y/N)
Rationale for
Selection or
Deletion
Input Form 2D
North Carolina DEQ Risk Calculator
DEQ Risk Calculator - Vapor Intrusion - Resident Soil Gas to Indoor Air
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
CAS #Chemical Name:
Soil Gas
Concentration
(ug/m3)
Calculated
Indoor Air
Concentration
(ug/m3)
Target Indoor
Air Conc. for
Carcinogens @
TCR = 1E-06
Target Indoor Air
Conc. for Non-
Carcinogens @
THQ = 0.2
Calculated
Carcinogenic
Risk
Calculated
Non-
Carcinogenic
Hazard
Quotient
67-64-1 Acetone 60.6 1.818 -6.5E+03 5.6E-05
71-43-2 Benzene 3.51 0.1053 3.6E-01 6.3E+00 2.9E-07 3.4E-03
75-15-0 Carbon Disulfide 220 6.6 -1.5E+02 9.0E-03
67-66-3 Chloroform 8.37 0.2511 1.2E-01 2.0E+01 2.1E-06 2.5E-03
74-87-3 Chloromethane 6.92 0.2076 -1.9E+01 2.2E-03
110-82-7 Cyclohexane 1.17 0.0351 -1.3E+03 5.6E-06
75-71-8 Dichlorodifluoromethane 4.64 0.1392 -2.1E+01 1.3E-03
100-41-4 Ethylbenzene 8.71 0.2613 1.1E+00 2.1E+02 2.3E-07 2.5E-04
109-99-9 ~Tetrahydrofuran 50.1 1.503 -4.2E+02 7.2E-04
142-82-5 Heptane, N-3.19 0.0957 -8.3E+01 2.3E-04
110-54-3 Hexane, N-2.98 0.0894 -1.5E+02 1.2E-04
67-63-0 Isopropanol 18.2 0.546 -4.2E+01 2.6E-03
78-93-3 Methyl Ethyl Ketone (2-Butanone)8.14 0.2442 -1.0E+03 4.7E-05
1634-04-4 Methyl tert-Butyl Ether (MTBE)3.96 0.1188 1.1E+01 6.3E+02 1.1E-08 3.8E-05
75-09-2 Methylene Chloride 1.26 0.0378 1.0E+02 1.3E+02 3.7E-10 6.0E-05
127-18-4 Tetrachloroethylene 3.93 0.1179 1.1E+01 8.3E+00 1.1E-08 2.8E-03
108-88-3 Toluene 32.8 0.984 -1.0E+03 1.9E-04
75-69-4 Trichlorofluoromethane 8.04 0.2412 --
95-63-6 Trimethylbenzene, 1,2,4-13.3 0.399 -1.3E+01 6.4E-03
108-67-8 Trimethylbenzene, 1,3,5-3.57 0.1071 -1.3E+01 1.7E-03
25167-70-8 Trimethylpentene, 2,4,4-1 0.03 --
106-42-3 Xylene, P-33.9 1.017 -2.1E+01 9.8E-03
108-38-3 Xylene, m-33.9 1.017 -2.1E+01 9.8E-03
95-47-6 Xylene, o-12.1 0.363 -2.1E+01 3.5E-03
Cumulative:2.6E-06 5.7E-02
All concentrations are in ug/m3
Output Form 3B
Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion
risk, no risk values are calculated for these chemicals.
North Carolina DEQ Risk Calculator
DEQ Risk Calculator - Vapor Intrusion - Non-Residential Worker Soil Gas to Indoor Air
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
CAS #Chemical Name:
Soil Gas
Concentration
(ug/m3)
Calculated
Indoor Air
Concentration
(ug/m3)
Target Indoor
Air Conc. for
Carcinogens @
TCR = 1E-06
Target Indoor Air
Conc. for Non-
Carcinogens @
THQ = 0.2
Calculated
Carcinogenic
Risk
Calculated
Non-
Carcinogenic
Hazard
Quotient
67-64-1 Acetone 60.6 0.606 -2.7E+04 4.5E-06
71-43-2 Benzene 3.51 0.0351 1.6E+00 2.6E+01 2.2E-08 2.7E-04
75-15-0 Carbon Disulfide 220 2.2 -6.1E+02 7.2E-04
67-66-3 Chloroform 8.37 0.0837 5.3E-01 8.6E+01 1.6E-07 1.9E-04
74-87-3 Chloromethane 6.92 0.0692 -7.9E+01 1.8E-04
110-82-7 Cyclohexane 1.17 0.0117 -5.3E+03 4.5E-07
75-71-8 Dichlorodifluoromethane 4.64 0.0464 -8.8E+01 1.1E-04
100-41-4 Ethylbenzene 8.71 0.0871 4.9E+00 8.8E+02 1.8E-08 2.0E-05
109-99-9 ~Tetrahydrofuran 50.1 0.501 -1.8E+03 5.7E-05
142-82-5 Heptane, N-3.19 0.0319 -3.5E+02 1.8E-05
110-54-3 Hexane, N-2.98 0.0298 -6.1E+02 9.7E-06
67-63-0 Isopropanol 18.2 0.182 -1.8E+02 2.1E-04
78-93-3 Methyl Ethyl Ketone (2-Butanone)8.14 0.0814 -4.4E+03 3.7E-06
1634-04-4 Methyl tert-Butyl Ether (MTBE)3.96 0.0396 4.7E+01 2.6E+03 8.4E-10 3.0E-06
75-09-2 Methylene Chloride 1.26 0.0126 1.2E+03 5.3E+02 1.0E-11 4.8E-06
127-18-4 Tetrachloroethylene 3.93 0.0393 4.7E+01 3.5E+01 8.3E-10 2.2E-04
108-88-3 Toluene 32.8 0.328 -4.4E+03 1.5E-05
75-69-4 Trichlorofluoromethane 8.04 0.0804 --
95-63-6 Trimethylbenzene, 1,2,4-13.3 0.133 -5.3E+01 5.1E-04
108-67-8 Trimethylbenzene, 1,3,5-3.57 0.0357 -5.3E+01 1.4E-04
25167-70-8 Trimethylpentene, 2,4,4-1 0.01 --
106-42-3 Xylene, P-33.9 0.339 -8.8E+01 7.7E-04
108-38-3 Xylene, m-33.9 0.339 -8.8E+01 7.7E-04
95-47-6 Xylene, o-12.1 0.121 -8.8E+01 2.8E-04
Cumulative:2.0E-07 4.5E-03
All concentrations are in ug/m3
Output Form 3E
Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk,
no risk values are calculated for these chemicals.
North Carolina DEQ Risk Calculator
Output Form 3E
North Carolina DEQ Risk Calculator
Risk for Individual Pathways Output Form 1A
Version Date: December 2019
Basis: November 2019 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Receptor Pathway Carcinogenic
Risk Hazard Index Risk exceeded?
Soil 3.8E-06 9.2E-02 NO
Groundwater Use*NC NC NC
Soil 8.7E-07 7.3E-03 NO
Groundwater Use*NC NC NC
Construction Worker Soil 1.4E-07 7.8E-02 NO
Soil 2.1E-06 4.9E-02 NO
Surface Water*NC NC NC
Receptor Pathway Carcinogenic
Risk Hazard Index Risk exceeded?
Groundwater to Indoor Air NC NC NC
Soil Gas to Indoor Air 2.6E-06 5.7E-02 NO
Indoor Air 0.0E+00 0.0E+00 NO
Groundwater to Indoor Air NC NC NC
Soil Gas to Indoor Air 2.0E-07 4.5E-03 NO
Indoor Air 0.0E+00 0.0E+00 NO
Pathway Source
Source Soil NM
Source Groundwater NM
Source Soil NM
Source Groundwater NM
3. NM = Not Modeled
4. NC = Pathway not complete
2. * = If concentrations in groundwater exceed the NC 2L Standards or IMAC, or concentrations in surface water exceed the
NC 2B Standards, appropriate remediation and/or institutional control measures will be necessary to be eligible for a risk-based
closure.
Surface Water Exceedence of 2B at Receptor?
Exceedence of 2B at Receptor?
VAPOR INTRUSION CALCULATORS
Resident
Non-Residential Worker
CONTAMINANT MIGRATION CALCULATORS
Target Receptor Concentrations Exceeded?
Groundwater Exceedence of 2L at Receptor?
Exceedence of 2L at Receptor?
1. If lead concentrations were entered in the exposure point concentration tables, see the individual calculator sheets for lead
concentrations in comparison to screening levels. Note that lead is not included in cumulative risk calculations.
Notes:
DIRECT CONTACT SOIL AND WATER CALCULATORS
Resident
Non-Residential Worker
Recreator/Trespasser
North Carolina DEQ Risk Calculator
Version Date:
Basis:
Site Name:
Site Address:
DEQ Section:
Site ID:
Exposure Unit ID:
Submittal Date:
Reviewed By:
North Carolina Department of Environmental Quality
Risk Calculator
Red Carpet Inn Brownfields Site
615 East Morehead Street, Charlotte, North Carolina
Brownfields
23070-19-060
January 2021
November 2020 EPA RSL Table
Prepared By:Terracon Consultants, Inc.
North Carolina DEQ Risk Calculator
Risk for Individual Pathways Output Form 1A
Version Date: January 2021
Basis: November 2020 EPA RSL Table
Site ID: 23070-19-060
Exposure Unit ID:
Receptor Pathway
Carcinogenic
Risk Hazard Index Risk exceeded?
Soil NC NC NC
Groundwater Use* NC NC NC
Soil NC NC NC
Groundwater Use* NC NC NC
Construction Worker Soil NC NC NC
Soil NC NC NC
Surface Water* NC NC NC
Receptor Pathway
Carcinogenic
Risk Hazard Index Risk exceeded?
Groundwater to Indoor Air NC NC NC
Soil Gas to Indoor Air 2.0E-06 5.1E-02 NO
Indoor Air NC NC NC
Groundwater to Indoor Air NC NC NC
Soil Gas to Indoor Air 1.5E-07 4.0E-03 NO
Indoor Air NC NC NC
Pathway Source
Source Soil NC
Source Groundwater NC
Source Soil NC
Source Groundwater NC
3. NM = Not Modeled
4. NC = Pathway not calculated
DIRECT CONTACT SOIL AND WATER CALCULATORS
Resident
Non-Residential Worker
Recreator/Trespasser
2. * = If concentrations in groundwater exceed the NC 2L Standards or IMAC, or concentrations in surface water exceed the
NC 2B Standards, appropriate remediation and/or institutional control measures will be necessary to be eligible for a risk-based
closure.
Surface Water Exceedence of 2B at Receptor?
Exceedence of 2B at Receptor?
VAPOR INTRUSION CALCULATORS
Resident
Non-Residential Worker
CONTAMINANT MIGRATION CALCULATORS
Target Receptor Concentrations Exceeded?
Groundwater Exceedence of 2L at Receptor?
Exceedence of 2L at Receptor?
1. If lead concentrations were entered in the exposure point concentration tables, see the individual calculator sheets for lead
concentrations in comparison to screening levels. Note that lead is not included in cumulative risk calculations.
Notes:
North Carolina DEQ Risk Calculator
Exposure Point ConcentrationsVersion Date: January 2021Basis: November 2020 EPA RSL TableSite ID: 23070-19-060Exposure Unit ID: Description of Exposure Point Concentration Selection:Exposure Point Concentration (ug/m3)Notes: CAS Number ChemicalMinimum Concentration (Qualifier)Maximum Concentration (Qualifier)UnitsLocation of Maximum ConcentrationDetection FrequencyRange of Detection LimitsConcentration Used for ScreeningBackground ValueScreening Toxicity Value (Screening Level) (n/c)Potential ARAR/TBC ValuePotential ARAR/TBC SourceCOPC Flag (Y/N)Rationale for Selection or Deletion55 67-64-1 Acetoneug/m311 71-43-2 Benzeneug/m33.5 67-66-3 Chloroformug/m35 100-41-4 Ethylbenzeneug/m346 142-82-5 Heptane, N-ug/m325 110-54-3 Hexane, N-ug/m37.9 67-63-0 Isopropanolug/m39.5 78-93-3 Methyl Ethyl Ketone (2-Butanone)ug/m3170 115-07-1 Propyleneug/m31.9 100-42-5 Styreneug/m31.4 127-18-4 Tetrachloroethyleneug/m3220 108-88-3 Tolueneug/m31.3 79-01-6 Trichloroethyleneug/m36.4 75-69-4 Trichlorofluoromethaneug/m32.5 95-63-6 Trimethylbenzene, 1,2,4-ug/m30.65 108-67-8 Trimethylbenzene, 1,3,5-ug/m313 106-42-3 Xylene, P-ug/m313 108-38-3 Xylene, m-ug/m35.5 95-47-6 Xylene, o-ug/m3Input Form 2DSoil Gas Exposure Point Concentration TableNote: Chemicals highlighted in orange are non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals.If the chemical list is changed from a prior calculator run, remember to select "See All Chemicals" on the data output sheet or newly added chemicals will not be included in risk calculationsNorth Carolina DEQ Risk Calculator