HomeMy WebLinkAbout16041_Fleming Labs_SIR_20211012 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 10/13/2021 1:17 PM I. Inspection Information Date & Time: 10/12/2021 2:31 PM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter Other Personnel: Kristin Cagney - Business owner (Summit Seltzer) Location: Lat: 35.2344403, Long: -80.8738124, Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 2 of 7 II. Project Information Number: 16041-12-060 Name: Fleming Laboratories-RFRU Address: 2205 - 2215 Thrift Road City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Commercial/Retail Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: Unknown Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: The VIMS is an active system consisting of 4 rooftop blowers, each connected to a field of vertical riser pipes. Each VIMS riser is equipped with a vacuum sampling port and labeling. The VIMS also consists of a main control panel, low vacuum alarms, and an auto-dialer. During the site inspection, the control panel, numerous risers, overhead piping, and floor sealing were inspected. A Magnahelic gauge on the control panel indicated Blower #4 may not be operational (Photo 4), and DEQ personnel were unable to access the roof-top to inspect blowers due to a locked roof-top ladder and used pallets blocking access (Photo 7). Summary: N/A Summary: Single story masonry Fleming lab building has been retrofitted into two brewery type facilitues. The northern portion of building is in use. While remodling on the southern portion of building (brewery and restaurant), has almost been completed. Summary: N/A Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Based on the presence of significant vacuum on each of the VIMS risers, public exposure does not appear to be a concern; however, the status of blower #4 needs to be confirmed. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Photo of the east side of the Former Fleming Lab building facing west across Thrift Rd. Site visit performed to confirm active VIMS is still operational during building renovation activities. Summit Seltzery (currently operating), is located within the northern portion of the building, and Midnight Mulligan Brewing, a brewery/restaurant, will be open to the public in the near future and is located within the southern portion of the property. As mentioned previously, blower #4 may not be operational. Vacuum was indicated on two vertical risers checked that are part of the field connected to Blower #4 using a Dwyer micromanometer; however, this could be residual sub-slab vacuum induced from the other three blowers pulling air from below the slab. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 5 of 7 Photo 2: Interior of Summit Seltzery located in northern portion of building. Photo 3: Brewing area within Summit Seltzery. There is a similar but larger brewing area within Midnight Mulligan Brewing in southern portion of building. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 6 of 7 Photo 4: Checking vacuum on VIMS riser SP 4-5. Measured 0.898 “WC using Dwyer micromanometer Photo 5: VIMS control panel. Blower #4 may not be operating based on Magnahelic gauge reading, although this could be a blower, gauge, or tubing issue. Sensaphone autodialer located below Magnahelic gauge panel and alarm lamp in center of panel are also visible. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 10/12/2021 2:31 PM Page 7 of 7 Photo 6: Overhead VIMS trunk lines painted black, yellow VIMS labels visible. Photo 7: Rooftop access ladder blocked by pallets and locked during Site Inspection preventing rooftop examination of VIMS blowers.