HomeMy WebLinkAbout22055_Charlotte Oil & Fertilizer_SIR_20210302 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 03/04/2021 11:47 AM I. Inspection Information Date & Time: 03/02/2021 2:51 PM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Jason Blanchard - Clean Vapor, and Kaitlynn Bryan-Scaggss - One Environmental Location: Lat: 35.20909, Long: -80.8621, II. Project Information Number: 22055-18-060 Name: Charlotte Oil & Fertilizer Address: 2151 Hawkins St. City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Mixed Use Structures on Property: New Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: Portions of sub-slab piping and VIMS riser piping observed in addition to remote sampling conduit/screens, helium supply and junction boxes, and Liquid Boot spray VI barrier being applied during visit. Observed coupon test of VI barrier while on- site. Summary: N/A Summary: 17-Story Mixed Use building currently under construction. Spray applied VIMS being installed during the construction process. Summary: soils exposed due to general construction activities. Brownfields Inspection Report: Charlotte Oil & Fertilizer, 22055-18-060 03/02/2021 2:51 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Site fenced with temporary construction fencing. Site access closely monitored at check- in station, with no environmental exposure to public observed at the time of the site inspection. Brownfields Inspection Report: Charlotte Oil & Fertilizer, 22055-18-060 03/02/2021 2:51 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Site photo looking northeast down Hawkins St. Examined portions of VIMS that was visible prior to installation of Liquid Boot VI barrier. Also observed installation of Liquid Boot barrier on another portion of site, discussed barrier installation with installers, and observed coupon sampling and thickness measurement. Coupon sampling holes to be used for smoke testing the following day. Brownfields Inspection Report: Charlotte Oil & Fertilizer, 22055-18-060 03/02/2021 2:51 PM Page 5 of 7 Photo 2: Photo of three steel VIMS Risers along interior wall. Future sub-slab soil gas and helium injection tubing visible exiting conduits at central monitoring location. Photo 3: Two VIMS trunk lines visible exiting stone layer. Brownfields Inspection Report: Charlotte Oil & Fertilizer, 22055-18-060 03/02/2021 2:51 PM Page 6 of 7 Photo 4: Sub-slab sample screen. Internal sample tubing and seal within conduit at screen not visible. Photo 5: Gray junction box (rear of photo) and two helium injection boxes (left side of photo) visible in photograph. Brownfields Inspection Report: Charlotte Oil & Fertilizer, 22055-18-060 03/02/2021 2:51 PM Page 7 of 7 Photo 6: Spraying Liquid Boot over VI-20 membrane. Photo 7: Coupon testing of VIMS barrier. Thickness measured was 85 mils.