Loading...
HomeMy WebLinkAboutMO-28244_47502_CA_UST-61_20210112_24 Hour Release and UST Leak Reporting FormUST-61 24-Hour Release and UST Leak Reporting Form. For Releases This form should be completed and submitted to the UST Section's regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or in NC suspected release (DWM USE ONLY) Suspected Contamination? (Y/N) Y Facility ID Number N/A Incident # Risk (H,I,L,U) Confirmed GW Contamination? (Y/N) N Date Leak Discovered 12/23/20 Received On Received By Confirmed Soil Contamination ?(Y/N) Y Comm/Non-Commercial? Non -Comm. Reported by (circle one): Phone, Fax or Report Samples Taken?(Y/N) Y Reg/Non-regulated? Non -Reg. Region Free Product? (Y/N) N If Yes, State Greatest Thickness N/A INCIDENT DESCRIPTION Incident Name: Allcea Property Address: 1951 Sequoia Hills Drive County: Cabarrus Regional Office (circle one): Asheville, Mooresville Fayetteville, City/Town: Harrisburg Zip Code: 28075 Raleigh, Washington, Wilmington, Winston-Salem Latitude (decimal degrees): N 35.31407000' Longitude (decimal degrees) : W 80.608193390 Obtained by: ®GPS Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors) ❑Topographic map ❑GISAddress matching ❑Other ❑Unknown Describe location: -Soil contamination confirmed by laboratory result of soil sample collected by hand auger on 12/15/20 (TPH results attached) -Only supply well within 150 feet of source area scheduled to be abandoned -Notice of Residual Petroleum signed by RP to be submitted -UST to be removed with next couple weeks HOW RELEASE WAS DISCOVERED (Release code) (Check one) ❑Release Detection Equipment or Methods ❑Visual/Odor ❑Groundwater Contamination ❑During UST Closure/Removal ❑Water in Tank ❑Surface Water Contamination ❑Property Transfer ❑Water Supply Well Contamination ®Other (specify) Hand Auger SOURCE OF CONTAMINATION Source of Release Cause of Release Type of Release Product Type Released (Check primary source) (Check primary cause) (Check one) (Check primary product type released) ® Tank ❑ Spill ® Petroleum ❑ Gasoline/ Diesel/ ❑ Diesel/Veg. Oil ❑ Piping ❑ Overfill ❑ Non -Petroleum Kerosene Blend ❑ Dispenser ® Corrosion ❑ Both ® Heating Oil ❑ Vegetable Oil 100% ❑ Other Petroleum ❑ El0 — E20 ❑ Submersible Turbine Pump ❑Physical/Mechanical Location Products ❑ ❑ Delivery Problem Damage (Check one) Metals ❑ E21 — E84 ❑ Install Problem ❑ E85 — E99 ❑ Spill Bucket ❑ Other Inorganics ❑ ❑Other [:]Facility[:]Ethanolnol 100% Other ❑ Other Organics ❑ Unknown ®Residence ❑ E01 — E09 ❑ Unknown ❑Other Definitions presented on reverse Definitions presented on reverse Ownership 1. Municipal 2. Military 3. Unknown O Private 5. Federal 6. County 7. State Operation Type 1. Public Service 2. Agricultural 0 Residential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining UST Form 61 (02/19) Page 1 of 2 IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes 0. No 3. Unknown Number of Water Supply Wells Affected Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Luz C. Alicea Point of Contact Address 1951 Sequoia Hills Drive City State Zip Code Telephone Number Harrisburg NC 28075 N/A UST SYSTEM OPERATOR UST Operator/Company Address Unknown City State Zip Code Telephone Number LANDOWNER AT LOCATION OF UST INCIDENT Landowner Address Luz C. Alicea 1951 Sequoia Hills Drive City State Zip Code Telephone Number Harrisburg NC 28075 N/A Draw Sketch of Area (showing two major road intersections) or Attach Map See Attached Map Person Reporting Incident Ben Robinson Company Paragon Environmental Consultants Inc. Telephone Number(336) 669-6037 Title Geologist Address P.O. Box 157, Thomasville, NC 27361 Date 1/12/21 UST Form 61 (02/19) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end -use equipment (Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined Case Narrative Waypoint. ANALYTICAL Paragon Environmental Consultants, Inc. Brandon Moore PO Box 157 Thomasville, NC 27361 NC Certification No. 402 NC Drinking Water Cert No. 37735 SC Certification No. 99012 Project: 1951 Sequoia Hills Dr. Lab Submittal Date: 12/16/2020 Work Order: 0120267 12/23/20 9:51 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, WAYPOINT ANALYTICAL a,j Angela D. Overcash Senior Project Manager Data Qualifiers Key Reference: DO Surrogates diluted out. BRL Below Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference * Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Waypoint Analytical. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 1 Of 6 0 Waypoint. ANALYTICAL Sample Receipt Summary 12/23/2020 Work Order: 0120267 Client Sample ID Lab Sample ID Matrix Date/Time Sampled Date/Time Received TI-5 0120267-01 Solid 12/15/20 15:40 12/16/20 15:10 Samples were received in good condition at 0.5 degrees C unless otherwise noted. This report should not be reproduced, except in its entirety, without the written consent of Waypoint Analytical. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 2 0f 6 Way poi nt . ANALYTICAL Waypoint ID Client ID 0120267-01 TI-5 Parameter Diesel Range Organics Summary of Detections 12/23/2020 Work Order: 0120267 Method Result *8015C 8700 Units mg/kg dry This report should not be reproduced, except in its entirety, without the written consent of Waypoint Analytical. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 3 0f 6 Laboratory Report • � 12/23/2020 PA Waynt.� ANALYTICAL Paragon Environmental Consultants, Inc. Project: 1951 Sequoia Hills Dr. Client Sample ID: TI-5 Attn: Brandon Moore Sample ID: 0120267-01 PO Box 157 Work Order: 0120267 Thomasville, NC 27361 Sample Matrix: Solid Time Collected: 12/15/20 15:40 Time Submitted: 12/16/20 15:10 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics 8700 mg/kg dry 460 150 50 *8015C 12/18/20 17:35 ZRC POL0378 Surrogate Recovery Control Limits o-Terphenyl 0 % 31-123 DO General Chemistry Parameters % Solids 76.2 % by 0.100 0.100 1 *SM2540 G 12/21/20 14:21 SMW POL0435 Weight This report should not be reproduced, except in its entirety, without the written consent of Waypoint Analytical. 449 Springbrook Road - P.O. Box 240543 - Charlotte, INC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 4 0f 6 ® Level II QC Report Waynt � 12/23/20 poi ANALYTICAL Paragon Environmental Consultants, Inc. Project: 1951 Sequoia Hills Dr. Work Order: 0120267 Attn: Brandon Moore Time Submitted: 12/16/2020 3:10:OOPM PO Box 157 Thomasville, NC 27361 Diesel Range Organics by GC/FID - Quality Control Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch POL0378 - 3546 Blank (POL0378-BLK1) Prepared & Analyzed: 12/18/20 Diesel Range Organics BRL 7.0 mg/kg wet Surrogate: o-Terphenyl 1.15 mg/kg wet 1.342 86 31-123 LCS (POL0378-BS1) Prepared &Analyzed: 12/18/20 Diesel Range Organics 55.8 7.0 mg/kg wet 67.05 83 46-126 Surrogate: o-Terphenyl 1.17 mg/kg wet 1.341 87 31-123 LCS Dup (POL0378-BSD1) Prepared &Analyzed: 12/18/20 Diesel Range Organics 57.0 7.0 mg/kg wet 66.69 85 46-126 2 20 Surrogate: o-Terphenyl 1.21 mg/kg wet 1.334 91 31-123 Sample Extraction Data Prep Method: 3546 Lab Number Batch Initial Final Date/Time 0120267-01 POL0378 30.06 g 1 mL 12/18/20 8:20 Prep Method: Solids, Dry Weight Lab Number Batch Initial Final Date/Time 0120267-01 POL0435 30 g 30 g 12/21/20 14:21 This report should not be reproduced, except in its entirety, without the written consent of Waypoint Analytical. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 5of6 Waypointo ANALYTICAL 449 Springbrook Road • Charlotte, NC 21217 Phone 704/529-6364 • Fax: 704/525-0409 Client Company Name:+ Report To/Contact Nam AAU r Reporting Address: P.e Box 147 c!� r CHAIN OF CUSTODY RECORD PAGE _ OF _ ,QUOTE # TOENSURE PROPER BILLING: Project Name: Short Hold Analysis (Yes) No) UST Project: • es) (NO) . *Please ATTACH any project sftecffic reporting (QC LEVE I IV) provisions ar/or QC Requirements Invoice To: Tdionpri Address: YES NO N/A Samples INTACT upon arrival? Received ON WET ICE? PROPER PRESERVATIVES indicated? Received WITHIN HOLDING TIMES? CUSTODY SEALS INTACT? VOLATILES rec'd W/OUT HEADSPACE? PROPER CONTAINERS used? • ��� _ TEMP: Therm l.D: R'T' j Observedy C lCorr.�-°C Phone: Fax (Yes)(No): Purchase Order No./Billing Reference Email Address: QMe0/ Ylo S L Requested Due Date ❑ 1 Day ❑ 2 Days ❑ 3 Days ❑ 4 Days N�5 Days EDD Type: PDFIX _ xcelOther "Working Days" ❑ 6-9 Days ❑ Standard 10 days ❑ Rush Work Must Be Pre Approved, Site Location Name: ok 1 rldlg. Samples received after 14:00 will be processed next business day. Site Location Physical Addres SI U 1 , (f DfW Turnaround time is based on business days, excluding weekends and holidays. drrts yr NC 2�075 (SEE REVERSE FOR TERMS & CONDITIONS REGARDING SERVICES RENDERED BY WAYPOINT ANALYTICAL, LLC TO CLIENT) TO BE FILLED IN BY CLIENT/SAMPLING PERSONNEL Certification: NELAC FL NC_X SC OTHER NIA Water Chlorinated: YES_ NO Sample Iced Upon Collection: YES K No TIME MATRIX SAMPLE CONTAINER ANALYSIS REQUESTED CLIENT SAMPLE DESCRIPTION DATE COLLECTED COLLECTED MILITARY HOURS (SOIL, WATER, OR SLUDGE) PRESERVA- TIVES REMARKS ID NO. *TYPE SEE BELOW NO. SIZE ToAk#l@S Soi I x • • . PRESS FIRMLY - 2 IES Sampler's Signatur _ 1 Sampled By (Print Name) %crivil", L/ 0064104 Affiliation DOWN U n relinquishing, Chain of Custody is your authorization for Waypoint Analytical to proceed with the analyses as requested above. Any changes must be S m' itted in writing to the Waypoint Analytical Project Manager. There will be charges for any changes after analyses have been initialized. LAB USE ONLY nquished By:,Jy;lgnature) I , Received By: (Signature) Date Military/Hours Additional Comments: Site Arrival Time: / I� �� (,I Z.5 in wished By: (Signature) FMceived y: (Signature) to Site Departure Time: Relinquished By: (Signature) Received For Waypoint Analytical By: Date Field Tech Fee: ) Z � ,? /s/d Mileage: Method or Shipment: NOTE: ALL SAMPLE COOLERS SHOULD BE TAPED SHUT WITH CUSTODY SEALS FOR TRANSP RTATION TO THE ORATORY. C Group No. ///��� SAMPLES ARE NOT ACCEPTED AND VERIFIED AGAINST CDC UNTIL RECEIVED AT THE LABO TORY. . ❑ Fed Ex ❑ UPS 9Hand-delivered OW aypoint Analytical Field Service ❑ Other / NPDES: UST, TER: ING SOLID GROWATER: FLD IL240THER: — SEE REVERSE FOR F❑ SC I ❑O NC ❑ SC TERMS & CONDITIONS ❑ NC ❑ SC � NC ❑ SC ❑ INCU ❑ SC ❑ NICK ❑ SC NC ❑ SCTE ❑❑ NC ❑ SC ❑❑ NCN ❑ SC ❑❑ NC I ❑ ❑ ❑ ❑ *CONTAINER TYPE CODES: Ate= Amber C = Clear G= Glass P = Plastic; TL = Teflon -Lined Cap VOA = Volatile Organics Analysis (Zero Head Space) Page 6 of 6 o gle Maps 1951 Sequoia Hills Dr Back CrL-ek r „q 1951 Sequoia Hills Dr, a Harrisburg, INC 28075 �A 7' 4' � r RR r CreeV, Paul Linker Rd Pau! Linker Rd A� ogle Map data ©2021 200 ft r r Beverly, Trudy From: Beverly, Trudy Sent: Tuesday, January 12, 2021 8:57 AM To: Ben Robinson Subject: RE: [External] Alicea Property UST-61 Received. Trudy Trudy Beverly, L.G. D IE �1 Hydrogeologist, Division of Waste Management _ North Carolina Department of Environmental Quality Q� LF Pa.rI n. of Lnorun,w 0MOT ` UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudy. B everlykncdenn gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: ht_pt s://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: hgps:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-proeram INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://deu.nc. eov/about/divisions/waste-manaeement/waste-manaeement-rules-data/waste-manaeement-eis-mans File Review Procedures: ht_pt s://deq.nc.gov/about/divisions/waste-manaeement/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): httns: //dea.nc. eov/about/divisions/waste-manaeement/laserfiche Document Submittal & UST File Names for Laserfiche Policies: httys:Hfiles.nc.eov/nedea/Waste%2OMana2ement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policy.odf https:Hfiles.nc.gov/ncdeg/Waste%2OManagement/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche.docx From: Ben Robinson [mailto:brobinson8915@gmail.com] Sent: Tuesday, January 12, 2021 8:28 AM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Subject: [External] Alicea Property UST-61 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Please find attached to this e-mail the UST-61 for the Alicea Property. Thank you very much! Ben Robinson, L.G. Paragon Environmental Consultants, Inc.