Loading...
HomeMy WebLinkAbout22047_University Place Mall_DC680002_20190730_IA and SG ReportAECOM AECOM Technical Services of North Carolina, Inc. 919.461.1100 tel 1600 Perimeter Park Drive, Suite 400 919.461.1415 fax Morrisville, NC 27560 July 30, 2019 North Carolina Department of Environmental Quality Division of Waste Management — DSCA Program 1646 Mail Service Center Raleigh, NC 27699 Att: Mr. Mike Cunningham DSCA Project Manager Re: June 2019 - Indoor Air and Soil Gas Sampling Report American Dry Cleaners DSCA Site ID #DC680002 201 South Estes Drive, Chapel Hill, Orange County, North Carolina Dear Mr. Cunningham: AECOM Technical Services of North Carolina, Inc. (includes legacy URS and legacy AECOM herein referred to as AECOM) is pleased to provide the attached Indoor Air and Soil Gas Sampling Report for the American Dry Cleaners (#DC680002) site located at 201 South Estes Drive, Chapel Hill, North Carolina. This report includes documentation pertaining to the indoor air and soil gas sampling activities that were completed at the site in June 2019. The activities documented herein were completed in accordance with State Lead Authorization for Work (SLAW) 028, as approved on February 28, 2019. Due to the potential risk of vapor intrusion from tetrachloroethene (PCE) contaminated groundwater to affect indoor air quality at the western portion of the Olin T. Binkley Church, periodic monitoring of soil gas and indoor air quality was implemented in June 2017. This included the installation and sampling of two permanent soil gas sampling points (SV-5 and SV-6) at the locations shown on Attachment 14. Comprehensive information specific to the installation and initial sampling of soil gas sampling points SV-5 and SV-6 in December 2016 is on file in the Groundwater and Vapor Monitoring Report, dated January 18, 2018. Pursuant to SLAW 028, AECOM replaced soil gas sampling point SV-6 with SV-6r as the intake to soil gas sampling point SV-6 had become flooded. . Soil gas sampling points SV-5 and SV-6r were sampled on June 14, 2019. The soil gas samples collected from SV-5 and SV-6r were analyzed for five DSCA contaminants of concern: PCE, trichloroethene (TCE), cis-1,2-dichloroethene (DCE), trans-1,2-DCE, and vinyl chloride using EPA Method TO-15 LL. Sampling results and locations are shown on Attachment 14. A summary of the soil gas quality results, as entered into DSCA risk calculators, is provided as follows: SV-5 (6/14/19) — non-residential worker o Acceptable cumulative carcinogenic risk between 1E-04 and 1E-05 (8.0E-05); and, o Unacceptable hazard index is greater than 1 (26). SV-5 (6/14/19) - resident o Unacceptable cumulative carcinogenic risk between 1E-02 and 1E-03 (1.4E-03); and, o Unacceptable hazard index is greater than 1 (330). A=COM Mr. Mike Cunningham American Dry Cleaners — DC680002 July 30, 2019 Page 2 of 3 SV-6r (6/14/19) — non-residential worker o Acceptable cumulative carcinogenic risk between 1E-05 and 1 E-06 (7.1E-06); and, o Unacceptable hazard index is greater than 1 (2.2). SV-6r (6/14/19) - resident o Unacceptable cumulative carcinogenic risk between 1E-03 and 1E-04 (1.2E-04); and, o Unacceptable hazard index is greater than 1 (28). Based on a review of soil gas quality data generated to date, concentrations of PCE in soil gas collected from SV-5 have increased from 75,800 micrograms per liter (µg/m3) to a high of 140,000 µg/m3 in June 2018 and decreased to 93,000 µg/m3 in June 2019. TCE concentrations have ranged from 24,900 µg/m3 in June 2017 to a high of 40,000 µg/m3 in June 2018 then decreased to 18,000 µg/m3 in June 2019. Due to water in the tubing during the June and December 2018 sampling events, limited data are available for SV-6. Soil gas sampling point SV-6r was installed adjacent to SV-6 during the June 2019 sampling event; therefore, no trend data is available. As part of continued evaluation of potential vapor intrusion to affect indoor air quality in the preschool classrooms located at the Olin T. Binkley Church, two indoor air samples (IA-2 and IA-3) were collected concurrent with the soil gas samples in June 2019. Each indoor air sample was collected using a passive Radiello sampler deployed for a period of 7 days from within two of the preschool classrooms located at the Olin T. Binkley Church. Sampling results and locations are shown on Attachment 14. A summary of the indoor air quality results, as entered into DSCA risk calculators, is provided as follows: • IA-2 (6/7/19 - 6/14/19) — non-residential worker o Acceptable cumulative carcinogenic risk less than 1E-06 (9.5E-07); and, o Acceptable hazard index is less than 1 (0.28). • IA-2 (6/7/19 - 6/14/19) - resident o Acceptable cumulative carcinogenic risk between 1E-05 and 1E-06 (4.8E-06); and o Unacceptable hazard index is greater than 1 (1.2). • IA-3 (6/7/19 - 6/14/19) - non-residential worker o Acceptable cumulative carcinogenic risk less than 1E-06 (6.8E-07); and o Acceptable cumulative hazard index is less than 1 (0.18). • IA-3 (6/7/19 - 6/14/19) - resident o Acceptable cumulative carcinogenic risk between 1E-05 and 1E-06 (3.0E-06); and o Acceptable cumulative hazard index is less than 1 (0.77) As documented above, indoor air contaminant concentrations at indoor air sample IA-2 present an acceptable cumulative carcinogenic risk and unacceptable risk for hazard index for residential exposure. As previously reported in Indoor Air, Soil Gas, and Groundwater Sampling Report, dated March 7, 2019, indoor air samples collected at sample locations IA-2 and IA-3 in December 2018 also indicated an exceedance of residential risk specific to hazard index. Additional indoor air sampling events were completed in January 2019 and February 2019 to determine if indoor air concentrations remained above acceptable risk levels. Both confirmatory sampling events indicated indoor air concentrations of PCE and TCE had slightly decreased to within calculated acceptable risk levels for residential use. The work was done in accordance with AECOM Contract N16004, dated January 3, 2017, and in accordance with the scope and estimates provided in the approved SLAW028. If you have any questions or require additional information, please do not hesitate to call either Rob MacWilliams at 704-499-4839 or Nick Shore at 919-461-1485. A=COM Mr. Mike Cunningham American Dry Cleaners — DC680002 July 30, 2019 Page 3 of 3 Sincerely, AECOM TECHNICAL SERVICES OF NORTH CAROLINA, INC. Nick Shore, PG Project Manager Enclosures Robert H. MacWilliams, PG Program Manager ANALYTICAL DATA TABLES Analytical Data Tables for North Carolina Dry -Cleaning Solvent Cleanup Act Program Facility Name: American Dry Cleaners 201 South Estes Drive, Chapel Hill, Orange County DSCA ID No.: DC680002 Submittal Date: July 2019 Prepared By: AECOM Technical Services of North Carolina, Inc. 1600 Perimeter Park Drive, Suite 400, Morrisville, North Carolina Table of Contents DSCA ID No.: DC680002 Table/ Att. No. Check box Description if included Tables Table 1 Site Chronology 0 Table 2 Analytical Data for Soil ❑ Table 3 Analytical Data for Sub -slab Gas ❑ Table 4 Analytical Data for Soil Gas 0 Table 5 Analytical Data for Indoor and Outdoor Air 0 Table 6 Monitoring Well Construction Data ❑ Table 7 Groundwater Elevation Data ❑ Table 8 Analytical Data for Groundwater ❑ Table 9 Analytical Data for Surface Water ❑ Table 10 Water Well(s) Survey Data ❑ Table 11 Analytical Data for Water Supply Well(s) ❑ Table 12 Analytical Data for Natural Attenuation Parameters ❑ Attachments Att. 1 Site map showing location(s) of soil boring(s). ❑ Att2 Soil contaminant concentration maps showing the concentration at each sampling point. El Att. 3 Soil isoconcentration maps. ❑ Att. 4 Site map showing location(s) of monitoring well(s). ❑ Att. 5 Well completion diagrams and records of construction submitted to state. ❑ Att. 6 Groundwater gradient map for each sampling event. ❑ Att. 7 PCE concentration map showing the concentration at each sampling point and isoconcentration map. However, if there are significant plumes for other dry- cleaning contaminants, contaminant concentration maps for each chemical of concern should be included. ❑ Att. 8 Groundwater concentration trend plots. ❑ Att. 9 Map showing location(s) of surface water sample(s) (if applicable). ❑ Att. 10 Surface water concentration map showing the concentration at each sampling point (if applicable). El Att. 11 USGS Quad map with plotted water well location(s) within the 1,500 foot and 0.5 mile radii of the site (if applicable). ❑ Att. 12 Site map showing location(s) of monitoring well(s) for natural attenuation parametc ❑ Att. 13 Site map showing location(s) of indoor air, outdoor air, or soil gas samples. ❑ Att. 14 Air and soil gas concentration map showing the concentration at each sampling point. Att.15 Signed laboratory analytical reports including chain -of custody and quality assurance/quality control (QA/QC) documentation (only if not previously submitted). Att. 16 DSCA Program Risk Calculators 17 Att. 17 Indoor Air Building Survey Form 0 Att. 18 ❑ Att. 19 ❑ Att. 20 ❑ Att. 21 ❑ Note: 1. All maps must include a bar scale, north arrow, site name, DSCA ID No., and date. Table 1: Site Chronology DSCA ID No.: DC680002 Chronology of Events Date Instructions: Brief description of all significant events that have occurred since a problem was suspected at the facility. Commence with the first date a problem was suspected and continue through the most recent activity described in the current report. 04/01/95 Chlorinated compounds detected by Withers & Ravenel (W&R) during removal and closure of Underground Storage Tanks. 05/01/95 W&R complete preliminary investigation, install one monitoring well at the site. 08/08/95 W&R conduct Phase II Investigation, install eight monitoring wells as the site. 02/01/96 W&R complete Phase III Investigation, excavating a total of 400 cubic yards of contaminated soil. 12/06/07 ECS Carolinas, LLP conduct groundwater assessment. 07/10/08 W&R sampled existing wells and prepared Prioritization Assessment Report. 10/22/08 W&R installed five off -site monitoring wells on neighboring Olin T. Binkley Church property. Report on this date documents these activities. 02/17/09 W&R authorized to conduct aggressive fluid vapor recovery event. Report on this date documents these activities and result of post AFVR groundwater monitoring. Site placed in quarterly monitoring by DSCA program. 04/17/09 Second AFVR event authorized and post event groundwater monitoring documented in report issued on this date. 08/04/09 Groundwater monitoring report submitted to DSCA. 11/11/09 Third AFVR event authorized and post event groundwater monitoring documented in report issued on this date. 02/19/09 Groundwater monitoring report submitted to DSCA. 04/15/10 Fourth AFVR event authorized and post event groundwater monitoring documented in report issued on this date. 05/27/10 Outdoor air, indoor air and sub slab vapor sampling on church property documented in report issued on this date. 08/17/10 First semi-annual indoor air monitoring event at church documented in report issued on this date. 09/14/10 Groundwater monitoring report submitted to DSCA. 12/01/10 Fifth AFVR event authorized and post event groundwater monitoring documented in report issued on this date. 02/21/11 Groundwater monitoring report submitted to DSCA. 02/23/11 Second semi-annual indoor air monitoring event at church documented in report issued on this date. 03/08/11 Soil vapor sampling report for Harris Teeter property to the west. 06/09/11 W&R completes underground injection control permit application to inject Adventus product EHC, and receives UIC permit to conduct pilot test. 06/13/11 Groundwater monitoring report submitted to DSCA. 06/30/11 Indoor air sampling at Harris Teeter documented in report issued on this date. O1/07/12 Draft injection pilot test (three month post injection) issued on this date. 11/07/12 One-year post injection pilot test report issued on this date. 04/15/13 W&R conducts hydrogeological study to find permeable saturated zone for injection on church property. Bedrock was encountered above the surficial water table at most geoprobe drilling locations, which would preclude use of geoprobe to do injection. Report issued on this date documents the study and findings. 09/24/13 End of W&R involvement in project due to expiration of contract. 11/12/13 Groundwater Sampling Event, conducted by AECOM. 12/6/13 - 12/13/13 Indoor/Outdoor Air Sampling Event, Conducted by AECOM. Page 1 of 2 Table 1: Site Chronology DSCA ID No.: DC680002 Chronology of Events Date Instructions: Brief description of all significant events that have occurred since a problem was suspected at the facility. Commence with the first date a problem was suspected and continue through the most recent activity described in the current report. 02/07/14 Groundwater Sampling Event, conducted by AECOM. 06/27/14 Installation of 4 groundwater monitoring wells 2W-9, 2W-10, 2W-11, and 2W-12 07/08/14 Groundwater Sampling Event, conducted by AECOM. 08/22/14 Soil gas sampling event, conducted by AECOM 03/19/15 Indoor Air Sampling Event, conducted by AECOM 06/17/15 Indoor Air Sampling Event, conducted by AECOM 1 1/23/15 Groundwater samples collected from wells MW-2, MW-3, 2W-4, 2W-5, 2W-9, 2W-10, 2W-11, and 2W-12. O1/11/16 Indoor Air Sampling Event, conducted by AECOM 06/06/16 Indoor Air Sampling Event, conducted by AECOM 12/12/16 Indoor Air (IA-2 and IA-3), Soil Vapor (SV-5 and SV-6), and Groundwater Sampling (MW-2, 2W-9, 2W-10, and 2W- 11) Event, conducted by URS. Two new soil vapor points (SV-5 and SV-6) were installed in the playground area of the Olin T. Binkley Memorial Church. 6/20/17 - 6/28/17 Indoor Air (IA-2 and IA-3) and Soil Vapor (SV-5 and SV-6) sampling event was conducted by AECOM. 12/12/17 - 12/18/17 Indoor Air (IA-2 and IA-3) and Soil Vapor (SV-5 and SV-6) sampling event was conducted by AECOM. 06/08/18 - 06/15/18 Indoor Air (IA-2 and IA-3) and Soil Vapor (SV-5) sampling event was conducted by AECOM. Soil vapor sampling point SV-6 had moisture in tubing and was not able to be sampled. 12/19/18 A soil vapor (SV-5) and limited groundwater sampling event of four wells (MW-2, 2W-9, 2W-10, and 2W-11) was conducted by AECOM. Soil vapor sampling point SV-6 had moisture in tubing and was not able to be sampled. 12/14/18 - 12/21/18 Indoor Air (IA-2 and IA-3) and Soil Vapor (SV-5) sampling event was conducted by AECOM. 01/11/19 - O1/18/19 Confirmatory 7-day indoor air samples (IA-2 and IA-3) were collected via Radiello samplers, and samples (IA-2[8-hr] and IA-3[8-hr]) were collected via 6-liter summa canisters on January 11, 2019. '02/08/19 - 02/15/19 Confirmatory 7-day indoor air samples (IA-2 and IA-3) were collected via Radiello samplersby AECOM. 02/14/19 Damaged monitoring well 2W-8 was abandoned by an NC Licensed Drilling contractor. 06/07/19 - 06/14/19 Indoor Air (IA-2 and IA-3) and Soil Vapor (SV-5 and SV-6r) sampling event was conducted by AECOM. Page 2 of 2 Table 4: Analytical Data for Soil Gas DSCA ID No.: DC680002 N 0 ' y U N N A N O O N A i O iL p iL iL Q� U W O N Q In/m3] SV-1 4 0.5h 03/01/11 NA 31.3 NA NA NA 361 NA <1.3 147 13.8 NA NA SV-2 4 0.5h 03/01/11 NA <1.5 NA NA NA <2.5 NA <1.5 <2.0 <0.94 NA NA SV-3 4 0.5h 03/01/11 NA <1.4 NA NA NA 16.9 NA <1.4 1.8 <0.87 NA NA SV-4 3 0.5h 03/01/11 NA 1.6 NA NA NA <1.4 NA 10.1 5.5 <0.87 NA NA 7 0.5h 12/12/16 NA 16,000 NA NA NA 150,000 NA 410 35,000 1 <5.1 NA NA 7 0.5 h 06/28/17 NA 9,740 NA NA NA 75,800 NA 347 24,900 <10.2 NA NA S V-5 7 0.5 h 12/12/17 NA 11,000 NA NA NA 86,000 NA 260 23,000 <5.1 NA NA 7 0.5 h 06/15/18 NA 18,000 NA NA NA 140,000 NA 480 40,000 <51 NA NA 7 0.5 h 12/19/18 NA 9,800 NA NA NA 120,000 NA 390 24,000 <38 NA NA 7 0.5 h 06/14/19 NA 6,000 NA NA NA 93,000 NA 320 18,000 <38 NA NA 7 0.5h 12/12/16 NA 880 NA NA NA 31,000 NA 190 4,800 <5.1 NA NA SV-6 7 0.5 h 06/28/17 NA 262 NA NA NA 3,850 NA 154 484 <1.02 NA NA 7 0.5 h 12/12/17 NA 830 NA NA NA 21,000 NA 98 3,300 <5.1 NA NA SV-6r 7 0.5 h 06/14/19 NA 81 NA NA NA 13,000 NA 66 1,300 <5.1 NA NA SGOI 3.33 0.5h 07/09/14 NA 19 NA NA NA 330 NA <1.2 110 <0.77 NA <1.2 SG02 3.33 0.5h 07/09/14 NA 180 NA NA NA 130,000 NA <140 920 <90 NA <140 SG03 3.33 0.5h 07/09/14 NA <22 NA NA NA 11,000 NA 1 <22 70 1 <14 NA <22 Indicate "G" for grab sample or for longer samples indicate the number of hours followed by "h". Page 1 of I Table 5: Analytical Data for Indoor and Outdoor Air DSCA ID No.: DC680002 r O 3 05/04/10 AD SU 8h ND ND ND ND NA 9.3 7.3 ND ND ND ND IA-1 07/22/10 AD P 7d NA ND NA NA NA 14 NA ND 0.93 ND NA 01/28/11 AD P 7d NA 0.13 NA NA NA 6.1 NA ND 6.6 ND NA 05/04/10 AD SU 8h ND ND ND ND NA 7.4 7.4 ND 10.8 ND ND 08/23/11 AD P 34d NA 0.14 NA NA NA 10.0 NA ND 1.0 ND NA 08/30/11 AD P 7d NA 0.33 NA NA NA 11.0 NA ND 1.3 ND NA 09/22/11 AD P 23d NA 0.13 NA NA NA 9.2 NA ND 0.96 ND NA 11/18/11 AD P 30d NA 0.075 NA NA NA 5.2 NA ND 0.58 ND NA 11/30/11 AD P 13d NA ND NA NA NA 3.6 NA ND 0.45 ND NA 03/01/12 AD P 10d NA ND NA NA NA 3.5 NA ND 0.41 ND NA 06/01/12 AD P 8d NA ND NA NA NA 5.1 NA ND 0.48 ND NA 09/04/12 AD P 5d NA 0.24 NA NA NA 10.0 NA ND 1.30 ND NA 12/13/13 AD P 7d NA 0.18 NA NA NA 4.9 NA ND 0.56 ND NA 03/19/15 AD P 7d NA <0.32 NA NA NA 1.9 NA <0.33 0.22 <0.44 NA IA-2 06/17/15 AD P 7d NA <0.32 NA NA NA 4 NA <0.33 0.47 <0.44 NA 01/11/16 AD P 8d NA <0.28 NA NA NA 2.4 NA <0.29 0.23 <0.28 NA 06/13/16 AD P 7d NA <0.32 NA NA NA 3.9 NA <0.33 0.39 <0.44 NA 12/12/16 AD P 7d NA <0.32 NA NA NA 4.0 NA <0.34 0.46 <0.45 NA 06/20/17 AD P 7d NA <0.28 NA NA NA 3.1 NA <0.29 0.35 <0.39 NA 12/18/17 AD P 7d NA <0.32 NA NA NA 4.3 NA <0.33 0.59 <0.44 NA 06/15/18 AD P 7d NA <0.24 NA NA NA 2.8 NA <1.2 <0.29 <0.15 NA 12/21/18 AD P 7d NA <0.24 NA NA NA 4.6 NA <1.2 1.9 <0.15 NA 01/11/19 AD SU 8h NA <0.14 NA NA NA 1.4 NA <0.14 0.15J <0.09 NA 01/18/19 AD P 7d NA <0.24 NA NA NA 2.6 NA <1.2 1.6 <0.15 NA 02/15/19 AD P 7d NA <0.24 NA NA NA 2.5 NA <1.2 1.6 <0.15 NA 06/14/19 AD P 7d NA <0.24 NA NA NA 29 NA <1.2 1 <0.15 NA 05/04/10 AD SU 8h 9.5 ND 3.0 ND NA 4.6 22.6 ND 8.8 ND 18.7 07/22/10 AD P 7d NA ND NA NA NA 12 NA ND 0.75 ND NA 01/28/11 AD P 7d NA 0.15 NA NA NA 7.1 NA ND 0.8 ND NA 08/23/11 AD P 34d NA 0.14 NA NA NA 9.8 NA ND 0.99 ND NA 08/30/11 AD P 7d NA 0.31 NA NA NA 12.0 NA ND 1.20 ND NA 09/22/11 AD P 23d NA 0.11 NA NA NA 8.1 NA ND 0.88 ND NA 11/18/11 AD P 30d NA 0.093 NA NA NA 6.2 NA ND 0.75 ND NA 11/30/11 AD P 13d NA ND NA NA NA 4.1 NA ND 0.51 ND NA 03/01/12 AD P 10d NA ND NA NA NA 3.8 NA ND 0.44 ND NA 06/01/12 AD P 8d NA ND NA NA NA 5.5 NA ND 0.50 ND NA 09/04/12 AD P 5d NA 0.28 NA NA NA 12.0 NA ND 1.50 ND NA 12/13/13 AD P 7d NA 0.19 NA NA NA 5.9 NA ND 0.68 ND NA IA-3 03/19/15 AD P 7d NA <0.32 NA NA NA 1.8 NA <0.33 0.21 <0.44 NA 06/17/15 AD P 7d NA <0.32 NA NA NA 4.4 NA <0.33 1 0.5 <0.44 NA 01/11/16 AD P 8d NA <0.28 NA NA NA 2.4 NA <0.29 0.24 <0.39 NA 06/13/16 AD P 7d NA <0.32 NA NA NA 3.4 NA <0.33 0.36 <0.44 NA 12/12/16 AD P 7d NA <0.32 NA NA NA 3.2 NA <0.34 0.34 <0.45 NA 06/20/17 AD P 7d NA <0.28 NA NA NA 3.2 NA <0.29 0.38 <0.39 NA 12/18/17 AD P 7d NA <0.32 NA NA NA 4.5 NA <0.33 0.59 <0.44 NA 06/15/18 AD P 7d NA <0.24 NA NA NA 2.9 NA <1.2 <0.29 <0.15 NA 12/21/18 AD P 7d NA <0.24 NA NA NA 5.9 NA 1 <1.2 2.1 <0.15 NA 01/11/19 AD SU 8-h NA <0.16 NA NA NA 1.4 NA <0.16 0.12J <0.01 NA 01/18/19 AD P 7d NA <0.24 NA NA NA 2.3 NA <1.2 1.4 <0.15 NA 02/15/19 AD P 7d NA <024 NA NA NA 1.8 NA <1.2 1.6 <0.15 NA 06/14/19 AD P 7d NA <0.24 NA NA NA 32 NA <1.2 1 <0.29 <0.15 NA IA4 05/04/10 AD SU Sh 0.8 ND ND ND NA 3.9 4.7 ND ND ND ND IA-5 05/04/10 AD SU 8h ND ND ND ND NA ND 1.5 ND ND ND ND 07/22/10 AD P 7d NA ND NA NA NA 5.1 NA ND 0.45 ND NA 06/15/11 AD SU 8h NA 3.9 NA NA NA 4.1 NA ND 0.18 ND NA IA-6 01/10/12 AD SU 8h NA 2.4 NA NA NA 1.6 NA ND 0.23 ND NA HT-IA-1 03/19/15 AD P 7d NA <0.32 NA NA NA 0.88 NA 10 C <0.14 <0.44 NA HT-IA-2 03/19/15 AD P 7d NA <0.32 NA NA NA 3.8 NA 9.0 C <0.14 1 <0.44 NA BG-1 05/04/10 AD SU Sh ND ND ND 0.98 NA ND 1.5 ND ND ND ND BG-2 05/04/10 AD SU Sh ND ND ND ND NA ND ND ND 1.8 ND ND OAA-1 12/13/13 AD P 7d NA ND NA NA NA ND NA ND ND ND NA Notes: Page 1 of4 Table 5(2): Additional Data for Indoor and Outdoor Air CA ID No.: DC680002 Is dry-cleaning facility at the site: Operating ❑ Pick-up Only ❑ Abandoned ❑' If facility is operating, solvents used are: Perc ❑ Petroleum ❑ Green Earth ❑ Other ❑ For the active or former dry-cleaning space, describe the type and location of the air handling/HVAC unit (for example - a shared unit supplying two adjacent spaces; unit located on the root): - The air handling/HVAC unit(s) are located on the roof of the Harris Teeter building. For any indoor air spaces tested, describe the current use of the space (for example - an ABC liquor store adjacent to the dry-cleaner, a residence approximately 200 feet from the dry-cleaner, etc.): Harris Teeter (former American Dry -Cleaners). Olin T. Hinkley Baptist Church preschool facility located 150 feet east (down gradient) of former American Dry Cleaners. For any other indoor spaces tested, describe the type and location of the air handling/HVAC unit (for example - a shared unit supplying two adjacent spaces; unit located on the roof): Olin T. Binkley Baptist Church - One air handling/HVAC unit is located on the roof of the west wing where the preschool classrooms are located. - One air handling/HVAC unit is located on the ground along the south wall where the preschool classrooms are located. - Three air handling/HVAC units are located on the roof of the east wing where the church offices are located. - One air handling/HVAC unit is located on the ground along the north wall of the east wing where church sactuary is located. Sampling location map that indicates where all indoor air samples were collected. The map should clearly indicate the names/types of businesses and residence names sampled and in the vicinity of the subject site that maybe of concern. Page 3 of 4 Table 5(3): Additional Data for Indoor and Outdoor Air 1 SCA ID No.: DC680002 Sample ID Name and Address for Sampling Location Property Owner Name, Address, and Phone Number Tenant Name, Address, and Phones Number IA-2 Olin T. Binkley Baptist Church Olin T. Binkley Baptist Church 1712 Willow Drive, Chapel Hill, NC 27514 1712 Willow Drive, Chapel Hill, NC 27514 919-9424964(office) Dale Osborne (Pastor) 919-923-3874 (cell) IA 3 HT-IA-1 Frank Rinaldo Harris Teeter, 2110 S Estes Drive, Chapel Hill, NC 27514 Madison University Mall LLC 2001 Pennsylvania Ave, NW Washington DC 20005 Jeff Hoffinan (Store Manager) 919-933-5700 (Work) HT-IA-1 (202) 741-3857 Page 4 of 4 ATTACHMENT 14 INDOOR AIR / SOIL GAS ANALYTICAL RESULTS MAP LEGEND Soil Gas Sample • Indoor/Ambient Air Sample 0 Site Location PCE - Tetrachloroethene TCE - Trichloroethene cis-1,2-DCE - cis-1,2-Dichloroethene trans-1,2-DCE - trans-1,2-Dichloroethene ug/m3 micrograms per cubic meter J Estimated Concentration Sample does not exceed acceptable 00 non-residential or residential risk. Sample exceeds acceptable residential risk • • based on the DSCA Groundwater to Indoor Air Resident Risk Calculator. Sample exceeds acceptable non-residential 00 risk based on the DSCA Groundwater to Indoor Air Non -Residential Risk Calculator. HARRIS TEETER -CENTER 0 R AM F IC� RY R 'LEA WILLOW DRIVE SV-6 (6/28/17) 00 PCE - 3,850 ug/m3 TCE - 484 ug/m3 cis-1,2-DCE - 262 ug/m3 trans-1,2-DCE - 154 ug/m3 SV-6 (12/12/17) • • PCE - 21,000 ug/m3 TCE - 3,300 ug/m3 cis-1,2-DCE - 830 ug/m3 trans-1,2-DCE - 98 ug/m3 SV-6 (6/15/18) Not Sampled SV-6 (12/19/18) Not Sampled SV-6R (6/14/19) • • PCE - 13,000 ug/m3 TCE - 1,300 ug/m3 cis-1,2-DCE - 81 ug/m3 trans-1,2-DCE - 66 ug/m3 SV-5 (6/28/17) • • -,� PCE - 75,800 ug/m3 TCE - 24,900 ug/m3 cis-1,2-DCE - 9,740 ug/m3 I�4• f trans-1,2-DCE - 347 ug/m3 SV-5 (12/12/17) e e PCE - 86,000 ug/m3 TCE - 23,000 ug/m3 cis-1,2-DCE - 11,000 ug/m3 trans-1,2-DCE - 260 ug/m3 SV-5 (6/15/18) 00 PCE - 140,000 ug/m3 TCE - 40,000 ug/m3 cis-1,2-DCE - 18,000 ug/m3 trans-1,2-DCE - 480 ug/m3 SV-5 (12/19/18) 00 PCE - 120,000 ug/m3 TCE - 24,000 ug/m3 cis-1,2-DCE - 9,800 ug/m3 trans-1,2-DCE - 390 ug/m3 SV-5 (6/14/19) 00 PCE - 93,000 ug/m3 + TCE - 18,000 ug/m3 cis-1,2-DCE - 6,000 ug/m3 trans-1,2-DCE - 320 ug/m3 l IA-3 (6/12/17 - 6/20/17) • • PCE - 3.2 ug/m3 TCE - 0.38 ug/m3 IA-3 (12/11/17-12/18/17) 0 O PCE - 4.5 ug/m3 TCE - 0.59 ug/m3 s IA-3 (6/8/18 - 6/15/18) 00 r PCE - 2.9 ug/m3 IA-3 (12/14/18-12/21/18) 00 PCE - 5.9 ug/m3 TCE - 2.1 ug/m3 IA-3 (8-hr) (1/11/19) 00 PCE - 1.4 ug/m3 TCE - 0.12 J ug/m3 IA-3 (1/11/19-1/18/19) 00 PCE - 2.3 ug/m3 TCE - 1.4 ug/m3 IA-3 (2/8/19 - 2/15/19) 00 PCE - 1.8 ug/m3 ' TCE - 1.6 ug/m3 IA-3 (6/7/19 - 6/14/19) 00 y 'a PCE - 32 ug/m3 OLIN T. BAPTIST IA-2 (6/12/17 - 6/20/17) • • - PCE - 3.1 ug/m3 TCE - 0.35 ug/m3 IA-2 (12/11/17-12/18/17) • • PCE - 4.3 ug/m3 TCE - 0.59 ug/m3 IA-2 (6/8/18 - 6/15/18) 00 PCE - 2.8 ug/m3 IA-2 (12/14/18-12/21/18) 00 PCE - 4.6 ug/m3 TCE - 1.9 ug/m3 IA-2 (8-hr) (1/11/19) 00 PCE - 1.4 ug/m3 TCE - 0.15 J ug/m3 IA-2 (1/11/19-1/18/19) 00 PCE - 2.6 ug/m3 TCE - 1.6 ug/m3 IA-2 (2/8/19 - 2/15/19) • • PCE - 2.5 ug/m3 TCE - 1.6 ug/m3 IA-2 (6/7/19 - 6/14/19) • 4D PCE - 29 ug/m3 TCE - 1.0 ug/m3 j 0 100 Feet Indoor Air/Soil Gas Results Map AECOM TECHNICAL SERVICES 5925CARNEOIE BOULEVARD, SUITE 370 COM OFNORTHCAEB20UE INC �� American Dry Cleaners N N 28209 201 South Estes Drive x °' J64�CHARLOTTE,NC TEL: (704) 553-6150 yam, b A FAX: (704) 553-6151 Chapel Hill, NC w 10 SHEET: S DSCA Site # DC680002 Attachment 14 ATTACHMENT 15 LABORATORY ANALYTICAL REPORT icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 June 28, 2019 Nick Shore AECOM-Morrisville NC 1600 Perimeter Park Drive Morrisville, NC 27560 Project Location: American Cleaners Client Job Number: Project Number: 60600676 Laboratory Work Order Number: 19F1004 Enclosed are results of analyses for samples received by the laboratory on June 17, 2019. If you have any questions concerning this report, please feel free to contact me. Sincerely, I,&, �. A�� Kerry K. McGee Project Manager QA Officer Katherine Allen Laboratory Manager Daren Damboragian Page 1 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 AECOM-Morrisville NC REPORT DATE: 6/28/2019 1600 Perimeter Park Drive Morrisville, NC 27560 PURCHASE ORDER NUMBER: 60600676 ATTN: Nick Shore PROJECT NUMBER: 60600676 ANALYTICAL SUMMARY WORK ORDER NUMBER: 19F1004 The results of analyses performed on the following samples submitted to the CON -TEST Analytical Laboratory are found in this report. PROJECT LOCATION: American Cleaners FIELD SAMPLE # LAB ID: MATRIX SAMPLE DESCRIPTION TEST SUB LAB SV-5 19F1004-01 Soil Gas EPATO-15 SV-6r 19171004-02 Soil Gas EPATO-15 IA-2 (610 HL) 19171004-03 Air RAD 130 IA-3 (611 HL) 19F1004-04 Air RAD 130 Page 2 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 CASE NARRATIVE SUMMARY All reported results are within defined laboratory quality control objectives unless listed below or otherwise qualified in this report. REVISED REPORT - 6/28/2019 - Sample i.d. edited for sample 19F1004-02 per client's request. For method Radiello RAD-130 - The sampling rates for trichloroethene and tetrachloroethene are as follows: trichloroethene = 69 mL/min, tetrachloroethene = 59 mL/min. The theoretical sampling rates for vinyl chloride, trans-1,2-dichloroethene, and cis-1,2-dichloroethene are estimated using Graham's Law and are as follows: vinyl chloride = 103 mL/min, trans-1,2-dichloroethene = 83 mL/min, cis-1,2-dichloroethene = 83 mL/min. The results for these 3 compounds are estimated values. EPA TO-15 Qualifications Elevated reporting limit due to high concentration of target compounds. Analyte & Samples(s) Qualified: 19F1004-01[SV--5], 19F1004-02[SV-6r] The results of analyses reported only relate to samples submitted to the Con -Test Analytical Laboratory for testing. I certify that the analyses listed above, unless specifically listed as subcontracted, if any, were performed under my direction according to the approved methodologies listed in this document, and that based upon my inquiry of those individuals immediately responsible for obtaining the information, the material contained in this report is, to the best of my knowledge and belief, accurate and complete. t&� L�. ALUtt Kerry K. McGee Project Manager Page 3 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 ANALYTICAL RESULTS Project Location: American Cleaners Sample Description/Location: Date Received: 6/17/2019 Sub Description/Location: Field Sample #: SV-5 Canister ID: 2004 Sample ID: 19F1004-01 Canister Size: 6 liter Sample Matrix: Soil Gas Flow Controller ID: 4367 Sampled: 6/14/2019 14:00 Sample Type: 30 min Work Order: 19171004 Initial Vacuum(in Hg): -30 Final Vacuum(in Hg): -5 Receipt Vacuum(in Hg): -5.3 Flow Controller Type: Fixed -Orifice Flow Controller Calibration RPD Pre and Post -Sampling: EPA TO-15 Sample Flags: RL-11 ppbv ug/m3 Date/Time Analyte Results RL MDL Flag/Qual Results RL MDL Dilution Analyzed Analyst cis-1,2-Dichloroethylene 1500 15 6.1 6000 59 24 300 6/21/19 22:16 BRF trans-1,2-Dichloroethylene 80 15 6.1 320 59 24 300 6/21/19 22:16 BRF Tetrachloroethylene 14000 15 8.3 93000 100 57 300 6/21/19 22:16 BRF Trichloroethylene 3300 15 6.1 18000 81 33 300 6/21/19 22:16 BRF Vinyl Chloride ND 15 9.4 ND 38 24 300 6/21/19 22:16 BRF Surrogates 4-Bromofluorobenzene (1) % Recovery 99.0 % REC Limits 70-130 6/21/19 22:16 Page 4 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 ANALYTICAL RESULTS Project Location: American Cleaners Sample Description/Location: Work Order: 19171004 Date Received: 6/17/2019 Sub Description/Location: Initial Vacuum(in Hg): -30 Field Sample #: SV-6r Canister ID: 1909 Final Vacuum(in Hg): -5 Sample ID: 19F1004-02 Canister Size: 6 liter Receipt Vacuum(in Hg): -4.2 Sample Matrix: Soil Gas Flow Controller ID: 4368 Flow Controller Type: Fixed -Orifice Sampled: 6/14/2019 14:50 Sample Type: 30 min Flow Controller Calibration RPD Pre and Post -Sampling: EPA TO-15 Sample Flags: RL-11 ppbv ug/m3 Date/Time Analyte Results RL MDL Flag/Qual Results RL MDL Dilution Analyzed Analyst cis-1,2-Dichloroethylene 20 2.0 0.82 81 7.9 3.2 40 6/21/19 23:45 BRF trans-1,2-Dichloroethylene 17 2.0 0.81 66 7.9 3.2 40 6/21/19 23:45 BRF Tetrachloroethylene 1900 2.0 1.1 13000 14 7.5 40 6/21/19 23:45 BRF Trichloroethylene 250 2.0 0.81 1300 11 4.3 40 6/21/19 23:45 BRF Vinyl Chloride ND 2.0 1.3 ND 5.1 3.2 40 6/21/19 23:45 BRF Surrogates % Recovery % REC Limits 4-Bromofluorobenzene (1) 96.7 70-130 6/21/19 23:45 Page 5 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 ANALYTICAL RESULTS Project Location: American Cleaners Sample Description/Location: Work Order: 19171004 Date Received: 6/17/2019 Sub Description/Location: Field Sample #: IA-2 (610 HL) Sample ID: 19F1004-03 Sample Matrix: Air Flow Controller ID: Sampled: 6/14/2019 11:40 Sample Type: Air Volume L: 10115 RAD 130 Total µg ug/m3 Date/Time Analyte Results RL MDL Flag/Qual Results RL MDL Dilution Analyzed Analyst Vinyl Chloride ND 0.16 ND 0.15 1 6/24/19 15:35 IMR trans-1,2-Dichloroethene ND 1.0 ND 1.2 1 6/24/19 15:35 IMR cis-1,2-Dichloroethene ND 0.20 ND 0.24 1 6/24/19 15:35 IMR Tichloroethene 0.71 0.20 1.0 0.29 1 6/24/19 15:35 IMR Tetrachloroethene 17 0.20 29 0.34 1 6/24/19 15:35 IMR Page 6 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 ANALYTICAL RESULTS Project Location: American Cleaners Sample Description/Location: Work Order: 19171004 Date Received: 6/17/2019 Sub Description/Location: Field Sample #: IA-3 (611 HL) Sample ID: 19F1004-04 Sample Matrix: Air Flow Controller ID: Sampled: 6/14/2019 11:45 Sample Type: Air Volume L: 10095 RAD 130 Total µg ug/m3 Date/Time Analyte Results RL MDL Flag/Qual Results RL MDL Dilution Analyzed Analyst Vinyl Chloride ND 0.16 ND 0.15 1 6/24/19 15:59 IMR trans-1,2-Dichloroethene ND 1.0 ND 1.2 1 6/24/19 15:59 IMR cis-1,2-Dichloroethene ND 0.20 ND 0.24 1 6/24/19 15:59 IMR Tichloroethene ND 0.20 ND 0.29 1 6/24/19 15:59 IMR Tetrachloroethene 19 0.20 32 0.34 1 6/24/19 15:59 IMR Page 7 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 Sample Extraction Data Prep Method: TO-15 Prep -EPA TO-15 Pre-Dil Pre-Dil Default Actual Pressure Pre Initial Final Injection Injection Lab Number [Field ID] Batch Dilution Dilution mL mL mL mL Date 19F1004-01 [SV-51 B234143 1.5 200 5 1000 400 400 06/21/19 19F1004-02 [SV-6r] B234143 1.5 1 N/A 1000 400 15 06/21/19 Prep Method: Radiello-RAD 130 Lab Number [Field ID] Batch Initial [Cartridge Final [mL] Date 19F1004-03 [IA-2 (610 HL)] B233916 1.00 2.00 06/21/19 19F1004-04 [IA-3 (611 HL)] B233916 1.00 2.00 06/21/19 Page 8 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 QUALITY CONTROL Miscellaneous Air Analyses - Quality Control Total µg ug/m3 Spike Level Source %REC RPD nalyte Results RL Results RL Total µg Result %REC Limits RPD Limit Flag/Qua Batch B233916 - Radiello Blank (B233916-BLKI) Prepared: 06/21/19 Analyzed: 06/24/19 Vinyl Chloride ND 0.16 trans-1,2-Dichloroethene ND 1.0 cis-1,2-Dichloroethene ND 0.20 Trichloroethene ND 0.20 Tetrachloroethene ND 0.20 LCS (B233916-BS1) Prepared: 06/21/19 Analyzed: 06/24/19 Vinyl Chloride 6.21 0.16 0.41 10.0 62.1 40-140 trans-1,2-Dichloroethene 7.84 1.0 10.0 78.4 40-140 cis-1,2-Dichloroethene 7.96 0.20 10.0 79.6 40-140 Trichloroethene 7.57 0.20 10.0 75.7 40-140 Tetrachloroethene 7.26 0.20 10.0 72.6 40-140 LCS Dup (B233916-BSD1) Prepared: 06/21/19 Analyzed: 06/24/19 Vinyl Chloride 7.30 0.16 0.41 10.0 73.0 40-140 16.1 30 trans-1,2-Dichloroethene 8.64 1.0 10.0 86.4 40-140 9.71 30 cis-1,2-Dichloroethene 9.35 0.20 10.0 93.5 40-140 16.0 30 Trichloroethene 8.93 0.20 10.0 89.3 40-140 16.5 30 Tetrachloroethene 8.84 0.20 10.0 88.4 40-140 19.6 30 Page 9 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 QUALITY CONTROL Air Toxics by EPA Compendium Methods - Quality Control ppbv ug/m3 Spike Level Source %REC RPD Analyte Results RL Results RL ppbv Result %REC Limits RPD Limit Flag/Qual Batch B234143 - TO-15 Prep Blank (B234143-BLKI) Prepared & Analyzed: 06/21/19 cis-1,2-Dichloroethylene ND 0.035 trans-1,2-Dichloroethylene ND 0.035 Tetrachloroethylene ND 0.035 Trichloroethylene ND 0.035 Vinyl Chloride ND 0.035 Surrogate: 4-Bromofluorobenzene (1) LCS (B234143-BSI) 7.74 8.00 96.8 Prepared & Analyzed: 06/21/19 70-130 cis-1,2-Dichloroethylene 3.71 5.00 74.2 70-130 trans-1,2-Dichloroethylene 4.36 5.00 87.2 70-130 Tetrachloroethylene 4.03 5.00 80.6 70-130 Trichloroethylene 3.96 5.00 79.1 70-130 Vinyl Chloride 3.96 5.00 79.2 70-130 Surrogate: 4-Bromofluorobenzene (1) 8.10 8.00 101 70-130 Page 10 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 * FAX 413/525-6405 " TEL. 413/525-2332 FLAG/QUALIFIER SUMMARY * QC result is outside of established limits. t Wide recovery limits established for difficult compound. $ Wide RPD limits established for difficult compound. # Data exceeded client recommended or regulatory level RL Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference LCS Laboratory Control Sample LCS Dup Duplicate Laboratory Control Sample MS Matrix Spike Sample MS Dup Duplicate Matrix Spike Sample REC Recovery QC Quality Control ppbv Parts per billion volume EPA United States Environmental Protection Agency % REC Percent Recovery ND Not Detected N/A Not Applicable DL Detection Limit NC Not Calculated LFB/LCS Lab Fortified Blank/Lab Control Sample ORP Oxidation -Reduction Potential wet Not dry weight corrected % wt Percent weight Kg Kilogram g Gram mg Milligram µg Microgram ng Nanogram L Liter mL Milliliter µL Microliter m3 Cubic Meter EPH Extractable Petroleum Hydrocarbons VPH Volatile Petroleum Hydrocarbons APH Air Petroleum Hydrocarbons FID Flame Ionization Detector PID Photo Ionization Detector Percent recoveries and relative percent differences (RPDs) are determined by the software using values in the calculation which have not been rounded. RL-11 Elevated reporting limit due to high concentration of target compounds. ANALYST TPH Thomas P. Hnitecki RAP RaisaA. Petraitis PEB Paula E. Blakeborough KKM Kerry K. McGee IMR Irina Raducan CLA Catherine L. Amrich CJM Christian J. Merchant BRF Brittany R. Fisk Page 11 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 INTERNAL STANDARD AREAAND RT SUMMARY EPA TO-15 Internal Standard Response RT Reference Response Reference RT Area % Area o/ Limits RT Diff RT Diff Limit Q Initial Cal Check (S036903-ICV1) Lab File ID: H1914916.13 Analyzed: 05/30/19 05:00 Bromochloromethane (1) 235809 9.19 250109 9.19 94 60 - 140 0.0000 +/-0.50 1,4-Difluorobenzene(1) 689777 11.092 642900 11.092 107 60-140 0.0000 +/-0.50 Chlorobenzene-d5(1) 629422 15.877 581108 15.877 108 60-140 0.0000 +/-0.50 INTERNAL STANDARD AREAAND RT SUMMARY RAD 130 Internal Standard Response RT Reference Response Reference RT Area % Area o/ Limits RT Diff RT Diff Limit Q LCS (B233916-BS1 Lab File ID: B0624002.13 Analyzed: 06/24/19 14:24 2-Fluorotoluene 8432989 13.31 7516154 13.305 112 50-200 0.0050 +/-0.50 LCS Dup (B233916-BSD1) Lab File ID: B0624003.13 Analyzed: 06/24/19 14:47 2-Fluorotoluene 8363106 13.311 7516154 13.305 111 50-200 0.0060 +/-0.50 Blank (B233916-BLK1) Lab File ID: B0624004.13 Analyzed: 06/24/19 15:11 2-Fluorotoluene 8032183 13.312 7516154 13.305 107 50-200 0.0070 +/-0.50 IA-2 (610 HL) (19171004-03) Lab File ID: B0624005.D Analyzed: 06/24/19 15:35 2-Fluorotoluene 7662341 13.313 7516154 13.305 102 50-200 0.0080 +/-0.50 IA-3 (611 HL) (19F1004-04) Lab File ID: B0624006.13 Analyzed: 06/24/19 15:59 2-Fluorotoluene 7657184 13.315 7516154 13.305 102 50-200 0.0100 +/-0.50 INTERNAL STANDARD AREAAND RT SUMMARY EPA TO-15 Internal Standard Response RT Reference Response Reference RT Area % Area % Limits RT Diff RT Diff Limit Q Calibration Check (S037442-CCVI) Lab File ID: H1917204.13 Analyzed: 06/21/19 11:26 Bromochloromethane (1) 243490 9.19 250109 9.19 97 60 - 140 0.0000 +/-0.50 1,4-Difluorobenzene (1) 622067 11.086 642900 11.092 97 60 - 140 -0.0060 +/-0.50 Chlorobenzene-d5 (1) 556147 15.877 581108 15.877 96 60 - 140 0.0000 +/-0.50 LCS (B234143-BS1 ) Lab File ID: 1-11917205.1) Analyzed: 06/21/19 12:12 Bromochloromethane (1) 248895 9.19 243490 9.19 102 60 - 140 0.0000 +/-0.50 1,4-Difluorobenzene(1) 635796 11.092 622067 11.086 102 60-140 0.0060 +/-0.50 Chlorobenzene-d5(1) 566663 15.877 556147 15.877 102 60-140 0.0000 +/-0.50 Blank (B234143-BLK1) Lab File ID: H1917207.13 Analyzed: 06/21/19 13:53 Bromochloromethane (1) 241533 9.19 243490 9.19 99 60 - 140 0.0000 +/-0.50 1,4-Difluorobenzene (1) 613077 11.085 622067 11.086 99 60 - 140 -0.0010 +/-0.50 Chlorobenzene-d5(1) 544820 15.877 556147 15.877 98 60-140 0.0000 +/-0.50 SV-5 (19F1004-01 ) Lab File ID: H1917215.13 Analyzed: 06/21/19 22:16 Bromochloromethane (1) 249280 9.196 243490 9.19 102 60 - 140 0.0060 +/-0.50 1,4-Difluorobenzene(1) 724102 11.092 622067 11.086 116 60-140 0.0060 +/-0.50 Chlorobenzene-d5(1) 642271 15.877 556147 15.877 115 60-140 0.0000 +/-0.50 Page 12 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 INTERNAL STANDARD AREAAND RT SUMMARY EPA TO-15 Internal Standard Response RT Reference Response Reference RT Area % Area % Limits RT Diff RT Diff Limit Q SV-6r (19F1004-02) Lab File ID: H1917217.D Analyzed: 06/21/19 23:45 Bromochloromethane (1) 230854 9.196 243490 9.19 95 60 - 140 0.0060 +/-0.50 1,4-Difluorobenzene(1) 636332 11.092 622067 11.086 102 60-140 0.0060 +/-0.50 Chlorobenzene-d5(1) 560094 15.877 556147 15.877 101 60-140 0.0000 +/-0.50 Page 13 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028 ` FAX 413/525-6405 " TEL. 413/525-2332 CONTINUING CALIBRATION CHECK EPA TO-15 S037442-CCV 1 COMPOUND TYPE CONC. (ppbv) RESPONSE FACTOR % DIFF / DRIFT STD CCV ICAL CCV MIN (#) CCV LIMIT (#) cis-1,2-Dichloroethylene A 5.00 3.77 1.064439 0.8021553 -24.6 30 trans-1,2-Dichloroethylene A 5.00 4.27 0.9846697 0.8408789 -14.6 30 Tetrachloroethylene A 5.00 4.09 0.5221659 0.4267332 -18.3 30 Trichloroethylene A 5.00 4.01 0.3789929 0.3037563 -19.9 30 Vinyl Chloride A 5.00 4.22 0.6859689 0.5789807 -15.6 30 # Column to be used to flag Response Factor and %Diff/Drift values with an asterisk * Values outside of QC limits Page 14 of 18 icon-tes w . ANALYTICAL LABORATORY 39 Spruce Street ` East Longmeadow, MA 01028 ' FAX 413/525-6405 " TEL. 413/525-2332 CERTIFICATIONS Certified Analyses included in this Report Analyte Certifications EPA TO-15 in Air cis-1,2-Dichloroethylene AIHA,FL,NY,ME,NH,VA trans-1,2-Dichloroethylene AIHA,NJ,NY,ME,NH,VA Tetrachloroethylene AIHA,FL,NJ,NYM E,NH,VA Trichloroethylene AIHA,FL,NJ,NY,ME,NH,VA Vinyl Chloride AIHA,FL,NJ,NY,ME,NH,VA The CON -TEST Environmental Laboratory operates under the following certifications and accreditations: Code Description Number Expires AIHA AIHA-LAP, LLC - ISO17025:2005 100033 03/l/2020 MA Massachusetts DEP M-MA100 06/30/2020 CT Connecticut Department of Publilc Health PH-0567 09/30/2019 NY New York State Department of Health 10899 NELAP 04/l/2020 NH-S New Hampshire Environmental Lab 2516 NELAP 02/5/2020 RI Rhode Island Department of Health LA000112 12/30/2019 NC North Carolina Div. of Water Quality 652 12/31/2019 NJ New Jersey DEP MA007 NELAP 06/30/2020 FL Florida Department of Health E871027 NELAP 06/30/2020 VT Vermont Department of Health Lead Laboratory LL015036 07/30/2020 ME State of Maine 2011028 06/9/2021 VA Commonwealth of Virginia 460217 12/14/2019 NH-P New Hampshire Environmental Lab 2557 NELAP 09/6/2019 VT-DW Vermont Department of Health Drinking Water VT-255716 06/12/2020 NC-DW North Carolina Department of Health 25703 07/31/2019 PA Commonwealth of Pennsylvania DEP 68-05812 06/30/2020 Page 15 of 18 «� a� °. o me � m�� R '�6p an - V a a + c 1°2. E°°� c ytaa�; c u a E e E C m CO Q N W � LL Lab Receipt Pressure Final Pressure Q] .O d H Initial Pressure u c t�Jl a to N m m� c`7 W 'w z CO n Ah E a r _� f ,_ .v R ❑ T T tV c0 u >y 6 U LULU i C? tl tl ✓ U h 0 R E .G x O N G E R � � G7 Q7 y F,- U Q E 4 d � G. LL 0. U N an RE 4 X W � t LDQm� W �O ptm�cc d � x �� n161 ��m w W F- !I II O O = p 2 u� it W z L g v>¢aLnnmp O w � � a r Ln H ] � H r � U � zti m a _ W E y G v v 0 Uj 0 R a a oc a a E H } < a o w w V R h u U U. a U C O t U Q Lf _ ❑ W ca o LU c Y J _ w vm O z a 3 O° t- z Lu Q C ¢ z W to 7 U0 L, r z b y L- W LU H Or Or a W y 2 f N i ❑ p 49 c z O u w 2 �r. z y r O U E E\ E E; E N A b .Q �� .y .✓.j v Page 16 of 18 Track your package or shipment with FedEx Tracking 77-5491829460`: Delivered Wednesday 6/19/2019 at 1.47 pry DELIVERED Signed for by- FFOUST GET STATUS UPDATES OBTAIN PROOF OF DELIVERY FROM TO Raleigh, NC US East Longn Meadlow, IVA US Shipment Facts TRACKING NUMBER SERVICE REFERENCE 775491229460 I=edEx Ground 80 WEIGHT DIMENSIONS TOTAL PIECES 10 lb,; / 4 54 kgs 22x740 in. 1 TERMS PACKAGING STANDARD TRANSIT Third Party Package 0 6/19/2019 SHIP DATE ACTUAL DELIVERY '; , wed 6i19/2019 1 47 p11 Mon 6/17/2019 Travel History Local Scan Time Wednesday, 6/19/2019 1,47 pm East Longmeadow, MA Delivered 4,25 am CHICOPEE, MA On FedEx vehicle for delivery 4,24 am CHICOPEE, MA At local FedEx facility 1-57 am MIDDLETOWN, CT Departed FedEx location Tuesday, 6/1W2019 Page 17 18 a -AA ,,,„ KAMN PTnW1,1 rr n.�;.,a� �< r.APF 1�,.a,;�� of https://www.fedex.comlapps/fedextrack/?action=track&trackingnumber=775491829460&cntry_code=us&locale=en_US 1/2 I Have Not Confirmed Sample Container' Numbers With Lab Staff Before Relinquishing Over ^N^L-V-r10^L- L--^OconAa-rr`C)ny Samples ................ # 2T> . Fieu .G017 Air Media Sample Receipt Checklist - (Rejection Criteria Listing - Using Acceptance Policy) Any False Statement will be brought to the attention of the Client - State True or False Client LP t?rn Received By Date How were the samples In Cooler received? In Box — Were samples within Temperature 13y Gun Compliance? 2-60C By Bla Was Custody Seal Intact? _ Was COC Relinquished ? Are there any loose caps/valves on any samples? Is COC in ink/ Legible?T DCOC l 1 d 11 Client - Analy (, f � • 1q, Time , Q 1 On Ice No Ice Ambient Melted Ice # Actual Temp - nk # Actual Temp - Were Samples Tampered with? Does Chain Agree With Samples? i nc u e a sis -r Sampler Name Pertinent Information? Project^ ID's� Collection Dates/Times Are Sample Labels filled out and legible? Are there Rushes? F Who was notified? Samples are received within holding time? Proper Media Used? Individually Certified Cans? Are there Trip Blanks? Is there enough Volume? Nut/Ferrule IC Train Summa Cans Tedlar Bags Tubing TO-17 Tubes T-Connector Radiello Syringe PufsITO-11 s Tedlar 18 of 18 ATTACHMENT 16 DSCA PROGRAM RISK CALCULATORS DSCA Indoor Air Risk Calculator - Cumulative Risk for Resident Version 6, November 2017 DSCA ID No: Name/Address of DSCA Site: Name/Address of Sampling Location Sampling Date: Sample ID: DC680002 American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC 1712 Willow Drive, Chapel Hill, Orange County, NC 6/14/2019 IA-2 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Risks are calculated for these values if indoor air concentrations are entered and indoor air screening levels have been established, but it should be noted that detections of these chemicals are likely not associated with vapor intrusion. All concentrations are in u2/tn3 Indoor Air Indoor Air Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Screening Level for Non- Calculated Carcinogenic 3 (ug/m) for Carcinogens Carcinogens @ Carcinogenic Risk Hazard @ TCR = 1E-06 TH 0.2 = 0. Quotient 156-59-2 Dichloroethylene, 1,2-cis- 156-60-5 Dichloroeth lene 1 2-trans- 127-18-4 Tetrachloroethylene 29 1.1E+01 8.3E+00 2.7E-06 7.0E-Ol 79-01-6 Trichloroeth lene 1 4.8E-21 4.2E-01 2.1E-06 4.8E-01 75-01-4 Vinyl Chloride 1.7E-Ol 2.1E+O1 Cumulative: I 4.8E-06 I1.2E+00 DSCA Indoor Air Risk Calculator - Cumulative Risk for Resident Version 6, November 2017 DSCA ID No: Name/Address of DSCA Site: Name/Address of Sampling Location Sampling Date: Sample ID: DC680002 American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC 1712 Willow Drive, Chapel Hill, Orange County, NC 6/14/2019 IA-3 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Risks are calculated for these values if indoor air concentrations are entered and indoor air screening levels have been established, but it should be noted that detections of these chemicals are likely not associated with vapor intrusion. All concentrations are in u2/tn3 Indoor Air Indoor Air Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Screening Level for Non- Calculated Carcinogenic 3 (ug/m) for Carcinogens Carcinogens @ Carcinogenic Risk Hazard @ TCR = 1E-06 TH 0.2 = 0. Quotient 156-59-2 Dichloroethylene, 1,2-cis- 156-60-5 Dichloroeth lene 1 2-trans- 127-18-4 Tetrachloroethylene 32 1.1E+01 8.3E+00 3.0E-06 7.7E-Ol 76 Trichloroeth lene .7E-011 4.2E-019-01- 1- 21E+0175-0 Cumulative: I 3.0E-06 I7.7E-Ol DSCA Indoor Air Risk Calculator - Cumulative Risk for Non -Residential Worker Version 6, November 2017 DSCA ID No: Name/Address of DSCA Site: Name/Address of Sampling Location Sampling Date: Sample ID: DC680002 American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC 1712 Willow Drive, Chapel Hill, Orange County, NC 6/14/2019 IA-2 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Risks are calculated for these values if indoor air concentrations are entered and indoor air screening levels have been established, but it should be noted that detections of these chemicals are likely not associated with vapor intrusion. All concentratinns are in ue/m3 Indoor Air Indoor Air Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Screening Level for Non- Calculated Carcinogenic a (ug/m) for Carcinogens Carcinogens @ Carcinogenic Risk Hazard @ TCR=1E-06 THQ = 0.2 Quotient 156-59-2 Dichloroeth lene 1 2-cis- 156-60-5 Dichloroethylene, 1,2-trans- 127-18-4 Tetrachloroeth lene 29 4.7E+01 3.5E+01 6.1E-07 1.7E-01 79-01-6 Trichloroethylene 1 3.0E+00 1.8E+00 3.3E-07 1.1E-01 75-01-4 Vinyl Chloride 2.8E+00 8.8E+01 Cumulative: I 9.5E-07 I2.8E-Ol DSCA Indoor Air Risk Calculator - Cumulative Risk for Non -Residential Worker Version 6, November 2017 DSCA ID No: Name/Address of DSCA Site: Name/Address of Sampling Location Sampling Date: Sample ID: DC680002 American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC 1712 Willow Drive, Chapel Hill, Orange County, NC 6/14/2019 IA-3 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Risks are calculated for these values if indoor air concentrations are entered and indoor air screening levels have been established, but it should be noted that detections of these chemicals are likely not associated with vapor intrusion. All concentratinns are in ue/m3 Indoor Air Indoor Air Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Screening Level for Non- Calculated Carcinogenic a (ug/m) for Carcinogens Carcinogens @ Carcinogenic Risk Hazard @ TCR=1E-06 THQ = 0.2 Quotient 156-59-2 Dichloroeth lene 1 2-cis- 156-60-5 Dichloroethylene, 1,2-trans- 127-18-4 Tetrachloroeth lene 32 4.7E+01 3.5E+01 6.8E-07 1.8E-01 79-01-6 Trichloroethylene 3.0E+00 1.8E+00 75-01-4 Vinyl Chloride 2.8E+00 8.8E+01 Cumulative: I 6.8E-07 I1.8E-0 l DSCA Soil Gas Risk Calculator - Cumulative Risk for Resident Version 6, November 2017 DSCA ID No: DC680002 Name/Address of DSCA Site: American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC Name/Address of Sampling Location: 1712 Willow Drive, Chapel Hill, Orange County, NC Sampling Date: 6/14/2019 Sample ID: SV-5 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals. All cnnnentratinns are in no/m3 Indoor Air Soil Gas Calculated Indoor Indoor Air Screening Leve] Calculated Non - CAS # Chemical Name: Concentration Air Concentration Screening Level for Non- Calculated Carcinogenic (ug/m,) (ug/m) for Carcinogens @ Carcinogens @ Carcinogenic Risk Hazard Quotient TCR = 1E-06 THQ 9 0.2 156-59-2 Dichloroeth lene 1 2-cis- 6000 180 156-60-5 Dichloroethylene, 1,2-trans- 320 9.6 127-18-4 Tetrachloroeth lene 93000 2790 1.1E+01 8.3E+00 2.6E-04 6.7E+01 79-01-6 Trichloroethylene 18000 540 4.8E-01 4.2E-01 l.1E-03 2.6E+02 75-01-4 Vinyl Chloride 1.7E-01 2.1E+01 Cumulative: I 1.4E-03 I 3.3E+02 DSCA Soil Gas Risk Calculator - Cumulative Risk for Resident Version 6, November 2017 DSCA ID No: DC680002 Name/Address of DSCA Site: American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC Name/Address of Sampling Location: 1712 Willow Drive, Chapel Hill, Orange County, NC Sampling Date: 6/14/2019 Sample ID: SV-6r Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals. All cnnnentratinns are in no/m3 Indoor Air Soil Gas Calculated Indoor Indoor Air Screening Leve] Calculated Non - CAS # Chemical Name: Concentration Air Concentration Screening Level for Non- Calculated Carcinogenic (ug/m) (ug/m') for Carcinogens @ Carcinogens @ Carcinogenic Risk Hazard Quotient TCR = 1E-06 THQ = 0.2 156-59-2 Dichloroeth lene 1 2-cis- 81 2.43 156-60-5 Dichloroethylene, 1,2-trans- 66 1.98 127-18-4 Tetrachloroeth lene 13000 390 1.1E+01 8.3E+00 3.6E-05 9.3E+00 79-01-6 Trichloroethylene 1300 39 4.8E-01 4.2E-01 8.2E-OS 1.9E+01 75-01-4 Vinyl Chloride 1.7E-01 2.1E+01 Cumulative: I 1.2E-04 I 2.8E+01 DSCA Soil Gas Risk Calculator - Cumulative Risk for Non -Residential Worker Version 6, November 2017 DSCA ID No: DC680002 Name/Address of DSCA Site: American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC Name/Address of Sampling Location: 1712 Willow Drive, Chapel Hill, Orange County, NC Sampling Date: 6/14/2019 Sample ID: SV-5 Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals. All rnn --tinna a in -/ma Indoor Air Soil Gas Calculated Indoor Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Air Concentration Screening Level for Non Calculated Carcinogenic s (ug/m) s (ug/m) for Carcinogens @ Carcinogens @ Carcinogenic Risk Hazard Quotient TCR= 1E-06 TH = 0.2 156-59-2 Dichloroethylene, 1,2-cis- 6000 60 156-60-5 Dichloroeth lene 1 2-trans- 320 3.2 127-18-4 Tetrachloroethylene 93000 930 4.7E+01 3.5E+O1 2.0E-OS 5.3E+00 79-01-6 Trichloroeth lene 18000 180 3.0E+00 1.8E+00 6.0E-OS 2.1E+01 75-01-4 Vinyl Chloride I I 2.8E+00 8.8E+01 Cumulative: I 8.0E-05 I 2.6E+01 DSCA Soil Gas Risk Calculator - Cumulative Risk for Non -Residential Worker Version 6, November 2017 DSCA ID No: DC680002 Name/Address of DSCA Site: American Dry Cleaners 201 S. Estes Drive, Chapel Hill, Orange County, NC Name/Address of Sampling Location: 1712 Willow Drive, Chapel Hill, Orange County, NC Sampling Date: 6/14/2019 Sample ID: SV-6r Carcinogenic risk and hazard quotient cells highlighted in orange are associated with non-volatile chemicals. Since these chemicals do not pose a vapor intrusion risk, no risk values are calculated for these chemicals. All rnn --tinna a in -/ma Indoor Air Soil Gas Calculated Indoor Indoor Air Screening Level Calculated Non - CAS # Chemical Name: Concentration Air Concentration Screening Level for Non Calculated Carcinogenic s (ug/m) s (ug/m) for Carcinogens @ Carcinogens @ Carcinogenic Risk Hazard Quotient TCR= 1E-06 TH = 0.2 156-59-2 Dichloroethylene, 1,2-cis- 81 0.81 156-60-5 Dichloroeth lene 1 2-trans- 66 0.66 127-18-4 Tetrachloroethylene 13000 130 4.7E+O1 3.5E+O1 2.8E-06 7.4E-01 79-01-6 Trichlorceth lene 1300 13 3.0E+00 1.8E+00 4.3E-06 1.5E+00 75-01-4 Vinyl Chloride 2.8E+00 8.8E+01 Cumulative: I 7.1E-06 I 2.2E+00 ATTACHMENT 17 INDOOR AIR SAMPLING BUILDING SURVEY FORM INDOOR AIR BUILDING SURVEY and SAMPLING FORM Site Name: RMt l Preparer's name: Preparer's affiliation: Psi—'c1} ,M Part I - Occupants DSCAID#:�2000�� Date: Phone #: S-\45 - y33 U Building Address: Q L-L— Property Contact: ►�jPrs l E �-, ti�i�� i . Owner / Renter /n I t 1�]�SS YrICiC� Contact's Phone: home ( ) work (qtq) "fy Z_ 41j (0 1 cell ( ) # of Building occupants: Children under age 13 ✓ Children age 13-18 Adults ,/ — c1-10RC(A -� ( ',*`RC5C\-r00t_- -- '5-)A'\ vVnq-cz. cAr-,Ps I V\,P-Pl-L- PROF 4 a'ct_t \l4z?- y So cc c,,-) P ('% 1si Part II — Building Characteristics Building type: residential / multi -family residential /office strip mall / commercial / industrial Describe building: 1 6-ropA SPL► —� LfC\3CL— Year constructed: _]gCIM Sensitive population: ay car / nursing home / hospital schoo / er (speci Number of floors below grade: (full basement / crawl space / slab on grad ) Number of floors at or above grade: I Depth of basement below grade surface: ft. Basement size: ft2 1.11 fi Basement floor construction: concrete / dirt / floating / stone / other (specify): Foundation walls: poured concrete / inder bloc / stone / other (specify) Basement sump present? Eau /11In Sump pump? a Water in sump? ter 7`-rr 1,��P \ Type of hea ' ircle all that apply): air circulat' hot air radiation wood steam radiation �atum hot water radiation kerosene heater electric baseboard of(specify): ]�5 N L—q�� Type of ventilat' cle all that apply): entral air condi ' ing mechanical fans athroom ventilation s individual air conditioning units kitchen range hood fan outside air in a e other (specify): Type of fuel d (circl ll that apply): aual / fuel oil / wood / coal / solar / kerosene Are the basement walls or floor sealed with waterproof paint or epoxy coatings? Yes Is there a whole house fan? Yes I0 Septic system? Yes / Yes (but not used) Irrigation/private well? Yes / Yes (but not used) Type of ground cover outside of building: grass oncrete sphalt other (specify) Existing subsurface depressurization (radon) system in place? Yes No active /passive Sub -slab vapor/moisture barrier in place? Yes / Co Type of barrier: Ply-2- yh2 , C �L F3 ec-D6-r HAS Part III - Outside Contaminant Sources Other stationary sources nearby (gas stations, emission stacks, etc.):-Q _ Heavy vehicular traffic nearby (or other mobile sources): p,�Q C) j­ Part IV - Indoor Contaminant Sources w L.L_pw Z"�R Identify all potential indoor sources found in the building (including attached garages), the location of the source (floor and room), and whether the item was removed from the building 48 hours prior to indoor air sampling event. Any ventilation implemented after removal of the items should be completed at least 24 hours prior to the commencement of the indoor air sampling event. Potential Sources Location(s) Removed (Yes / No / NA) Gasoline storage cans Gas -powered equipment Kerosene storage cans Paints / thinners / strippers Cleaning solvents �� Oven cleaners Carpet / upholstery cleaners Other house cleaning products t r M Moth balls Polishes / waxes Insecticides Furniture / floor polish Nail polish / polish remover Hairspray Cologne / perfume Air fresheners Fuel tank (inside building) NA Wood stove or fireplace NA New furniture / upholstery New carpeting / flooring NA Bobbies - glues, paints, etc. Part V — Miscellaneous Items Do any occupants of the building smoke? Yes / No How often? Last time someone smoked in the building? hours /days ago Does the building have an attached garage directly connected to living space? Yes / No If so, is a car usually parked in the garage? Yes / No Are gas -powered equipment or cans of gasoline/fuels stored in the garage? Yes / No Do the occupants of the building have their clothes dry cleaned? Q / No If yes, how often? weekly / monthly / 3-4 times a year Do any of the occupants use solvents in work? Yes I �o If yes, what types of solvents are used? If yes, are their clothes washed at work? Yes / No Have any pesticides/herbicides been applied around the building or in the yard? Yes 1 If so, when and which chemicals? Has there ever been a fire in the building? Yes / 6) If yes, when? Has painting or staining been done in the building in the last 6 months? Yes /(E) If yes, when and where? Part VI -- Sampling Information Sample Technician: �, 'PLC EEF. L_ , - Phone number: (01 ►no S%� - �A33C Sample Source: ndoor Ai / Crawlspace Air / Sub -Slab / Near Slab Soil Gas xterior Soil G s Sampler Type: Tedlar bag / Sorbent / tainless Steel Canis er / �(specify), Analytical Metho 0-)51 0-17 / other: ��' I CD Cert. Laboratory: CQl_ Sample locations (floor, room): Field ID # _ - _U _ ICField ID # - Co I I H L Field ID # Field 1D # - Were "Instructions for Occupants" followed? es No If not, describe modifications: Aj! erXjL—N Provide Drawing of Sample Location(s) in Building Part VII - Meteorological Conditions Was there significant precipitation within 12 hours prior to (or during) the sampling event? Yes / No Describe the general weather conditions: tN Lx) T46 S wE tt.3yanF S�L4 InIC-11]EE"'Pri -- P���oas ot= 'C>P5� Part VIII — General Observations Provide any information that may be pertinent to the sampling event and may assist in the data interpretation process (e.g., observed that drycleaner operated with door or windows propped open for ventilation). (Adapted from the NJDEP Vapor Intrusion Guidance, October 2005)