Loading...
HomeMy WebLinkAbout23002_Stax Gym_SIR_20210326 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 03/29/2021 11:52 AM I. Inspection Information Date & Time: 03/25/2021 12:29 PM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter Other Personnel: Mark Wiherspoon- Sanders Utilities superintendent of tunnel division. Location: Lat: 35.19343, Long: -80.87984, Brownfields Inspection Report: Stax Gym, 23002-19-060 03/25/2021 12:29 PM Page 2 of 6 II. Project Information Number: 23002-19-060 Name: Stax Gym Address: 3722 South Tryon Street City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Recreation/Festival Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Not Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: N/A Summary: N/A Summary: Demolition taking place at time of Site Inspection. Most of the site structures have been torn down with exception of multi-level driving range at rear of property. Demolition company not on-site the day of the inspection. Summary: Stockpiled soils adjacent to a 32' diameter utility shaft. Shaft will be excavated to a depth of approximately 21 feet bls. At that depth, a horizontal boring machine will be lowered into the shaft and bore an approximately 60" borehole below S. Tryon and the Yorkshire Dr. Brownfield site, to cross street to the east. Brownfields Inspection Report: Stax Gym, 23002-19-060 03/25/2021 12:29 PM Page 3 of 6 Use of Basements: Not Observed Basement Violation: Yes Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Site perimeter enclosed by temporary construction fencing, and concrete barricades along S. Tryon St. No current exposure observed to general public at the time of the site inspection. Requested to see copy of EMP for work being performed at the site, and one was not available at the site. The job superintendent made it clear one would be brought out to the site the following day. Brownfields Inspection Report: Stax Gym, 23002-19-060 03/25/2021 12:29 PM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Demolition actively underway at former Stax Gym property. Demolition company not on-site during the site inspection. Building slabs not disturbed at time of Site Inspection. Met with Mr. Mark Witherspoon, site superintendent – Sanders Utility Construction Co. on-site. Excavating to 32’ shaft to approximate depth of 20 feet bgs at which point, a 60” dia. hole will be bored to the east below S. Tryon and Yorkshire Drive site to connect to existing utility lines. Groundwater encountered will be pumped into frac tanks, and tested before disposal. Excavated soil is being stockpiled, will be used to refill vertical shaft following completion of utility installation. Horizontal soil generated during horizontal slurry drilling will fall out of slurry into sealed containers prior to being tested and disposed of at landfill. Brownfields Inspection Report: Stax Gym, 23002-19-060 03/25/2021 12:29 PM Page 5 of 6 Photo 2: Additional building demolition photo facing west. Photo 3: Utility shaft being constructed along eastern portion of site adjacent to S. Tryon. No protective fencing installed yet although shaft only 4-5 ft below grade at time of site inspection. Brownfields Inspection Report: Stax Gym, 23002-19-060 03/25/2021 12:29 PM Page 6 of 6 Photo 4: Interior of vertical utility shaft. Photo 5: Stockpiled soils from utility shaft. Soil pile will become significantly larger due to proposed excavation depth. Soil pile not lined or covered at the time of inspection.