HomeMy WebLinkAbout21024_Block 42_SIR_ 2020.01.14 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 01/16/2020 9:27 AM I. Inspection Information Date & Time: 01/14/2020 2:00 PM Inspection Type: Meeting - Liner Inspection Brownfields Staff: Kevin Slaughter Other Personnel: Andrew Besu H&H Location: Lat: 35.22937, Long: -80.83651, Brownfields Inspection Report: Block 42, 21024-17-060 01/14/2020 2:00 PM Page 2 of 6 II. Project Information Number: 21024-17-060 Name: Block 42 Address: 212 City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Commercial/Retail Structures on Property: New Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: Onsite for VIMS liner (Drago Wrap) inspection on southeast portion of building, slightly north of future "Retail A" pour back area. Areas being inspected consist of a currently open area approximately 50’x50’ in addition to a smaller interior space measuring approximately 15’x25’. Summary: N/A Summary: Commercial/Residential currently under construction. Summary: Grading of "Retail A" area observed while onsite. Brownfields Inspection Report: Block 42, 21024-17-060 01/14/2020 2:00 PM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Construction site surrounded with chain link construction fencing with strict entry requirements. No public risk observed. Brownfields Inspection Report: Block 42, 21024-17-060 01/14/2020 2:00 PM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Larger VIMS liner (Drago Wrap) area being inspected prior to concrete pour. “Drago Tape” used for all penetration sealing and repairs as opposed to optional “Drago Sealant”. Onsite for VIMS liner inspection. Andrew B. with H&H identified numerous seams, liner punctures, and retaping of penetrations that needed to be addressed prior to pouring concrete. Site workers marked locations and made identified repairs while H&H and DEQ personnel on-site. Brownfields Inspection Report: Block 42, 21024-17-060 01/14/2020 2:00 PM Page 5 of 6 Photo 2: Smaller secondary interior area also inspected prior to concrete pour. Photo 3: Typical puncture in VIMS liner identified and marked prior to repair. Brownfields Inspection Report: Block 42, 21024-17-060 01/14/2020 2:00 PM Page 6 of 6 Photo 4: Site workers cleaning around two rebar penetrations prior to sealing VIMS liner. Photo 5: Seam in VIMS liner identified during inspection that was not taped. Due to dried mud on liner, extensive cleaning required, and seam not taped prior to departing site.