HomeMy WebLinkAboutMO-9540_40972_C_NRP_20200114_Filed NRP & Tank Closure ReportB34203 - P645
FOR REGISTRATION
Fredrick Smith
REGISTMecklenburERCounttyOF EONC
2020 JAN 14 02:54:93 PM
BK:34203 PG:645-649
FE:INSTRUMENT$#62020006178
JONESAW
NOTICE OF RESIDUAL PETROLEUM
George Linville Property MecklenburgCounty, North Carolina
(Site name)
The property that is the subject of this Notice (hereinafter referred to as the "Site")
contains residual petroleum and is an Underground Storage Tank (UST) incident under North
Carolina's Statutes and Regulations, which consist of N.C.G.S. 143-215.94 and regulations adopted
thereunder. This Notice is part of a remedial action for the Site that has been approved by the
Secretary (or his/her delegate) of the North Carolina Department of Environmental Quality (or its
successor in function), as authorized by N.C.G.S. Section 143B-279.9 and 143B-279.11. The North
Carolina Department of Environmental Quality shall hereinafter be referred to as "DEQ".
NOTICE
Petroleum product was released and/or discharged at the Site. Petroleum constituents remain
on the site, but are not a danger to public health and the environment, provided that the
restrictions described herein, and any other measures required by DEQ pursuant to N.C.G.S.
Sections 143B-279.9 and 143B-279.11, are strictly complied with. This "Notice of Residual
Petroleum" is composed of a description of the property, the location of the residual petroleum and the
land use restrictions on the Site. The Notice has been approved and notarized by DEQ pursuant to
N.C.G.S. Sections 143B-279.9 and 143B-279.11 and has/shall be recorded at the
Mecklenburg Register of Deeds' office Book , Page
(name of county)
Any map or plat required by DEQ has been/shall be recorded at the Mecklenburg Register of
(name of county)
Deeds' office Book , Page , and has been/shall be incorporated into the Notice by this reference.
Source Property
George Linville of Charlotte, North Carolina
(Owner's name) (city & state ofhomeowner)
is the owner in fee simple of all or a portion of the Site, which is located in the County of Mecklenburg ,
State of North Carolina, and is known and legally described as:
Being all of Lot 9 of Echo Hills Subdivision, Section 3 as same is shown on map thereof
recorded in Book 1487 at Page 437 in the Mecklenburg Public Registry. (Excerpted from
Mecklenburg County Register of Deeds Book 31753, Page 360).
Return to: Revised January 15, 2013
Cedar Rock Environmental, P. C. Page 1 of 4
107 Pioneer Trail
Graham, NC 27253
B34203 - P646
For protection of public health and the environment, the following land use restrictions required
by N.C.G.S. Section 143B-279.9(b) shall apply to all of the above -described real property. These
restrictions shall continue in effect as long as residual petroleum remains on the site in excess of
unrestricted use standards and cannot be amended or cancelled unless and until the Mecklenburg County
Register of Deed receives and records the written concurrence of the Secretary (or his/her delegate) of
DEQ (or its successor in function).
PERPETUAL LAND USE RESTRICTIONS
Soil: Soil containing residual petroleum above applicable regulatory standard(s) remains on the site in
the area identified in Figure 1, Attachment A. No soil shall be excavated or disturbed within 3
feet of the area identified in Figure 1 Attachment A except to remediate the soil in accordance
with all applicable state and federal statutes, regulations and guidelines.
Groundwater: Groundwater from the site is prohibited from use as a water supply. Water supply wells
of any kind shall not be installed or operated on the site.
ENFORCEMENT
The above land use restriction(s) shall be enforced by any owner, operator, or other party
responsible for the Site. The above land use restriction(s) may also be enforced by DEQ through any of
the remedies provided by law or by means of a civil action, and may also be enforced by any unit of local
government having jurisdiction over any part of the Site. Any attempt to cancel this Notice without the
approval of DEQ (or its successor in function) shall be subject to enforcement by DEQ to the full extent
of the law. Failure by any party required or authorized to enforce any of the above restriction(s) shall in
no event be deemed a waiver of the right to do so thereafter as to the same violation or as to one occurring
prior or subsequent thereto.
Revised January 15, 2013
Page 2 of 4
B34203 - P647
IN WITNESS WHEREOF, George Linville has caused this Notice to be executed pursuant to
N.C.G.S. Sections 14313-279.9 and 14313-279.11, this 13`f' day of January , 2020.
Georize Linville
name ofresponsible party if agent is signing)
By:
(signature of responsible party, att ney or other agent if there is one)
President. Cedar Rock Environmental P. C.
(Title of agent for responsible parry if there is one)
Signatory's name typed or printed: Robert A. Payne
NORTH CAROLINA
A (arvwnc..e COUNTY
(Name ofcounty in which acknowledgment was taken)
I certify that the following person personally appeared before me this day, acknowledging to me that he or
she signed the foregoing document: Robert A. Payne
Date: 13, ZeqZy
(Official Seal)
JOSIAH D PAYNE
NOTARY PUBLIC
AIAMANCE COUNTY, N.C.
My Commission Expires 10-22-2020.
signature ofNotary Public)
printed or typed name of Notary Public)
Notary Public
My commission expires: Z Zv z o
Revised January 15, 2013
Page 3 of 4
B34203 - P648
Approved for the purposes fN.C.G.S. 143B-279.11
�(A �__
(signature of Regional Supervisor)
I A.)�LWegional Supervisor
(printed name of Regional Supervisor)
Winston-Salem Regional Office
UST Section
Division of Waste Management
Department of Environment Quality
NORTH CAROLINA
t-0'-S u - COUNTY
(Name of coutty in which acknowledgment was taken)
I certify that the following person(s) personally appeared before me this day, each acknowledging to me
that he or she signed the foregoing document: C.c-ri � Gu Krol"^ (full printed name of Regional Supervisor)
Date: TvnL�Gty l y t 20 Zp
l�
(Official Seal) ( gnature of Notary Public)
1��/AL
JOSIAH D PAYNE printed or typed name of Notary Public)
NOTARY PUBLIC Notary Public
ALAMANCE COUNTY, N.C.
My Coaenission Expires 10-22-2020.
My commission expires: 0e4, 221 20 zo
Revised January 15, 2013
Page 4 of 4
1334203 - P649
ATTACHMENT A
N NOTE:
This map may not be a certified survey
and has not been reviewed by a local
government agency for compliance with
any applicable land development regulations
and has not been reviewed for compliance
with recording requirements for plats.
t
Mohigan Street
Peter Conn
Property
/ T1�
House
T2
PCY Properties LLC Carol Walker
Property Property
Ronald Armeen
Property \ '
Ronald Armeen
Property
RESTRICTED AREA (estimated
extent of soil contamination
exceeding applicable cleanup standards.)
0
20 ao
ao — —
Property Lines
T1 = 540-Gallon UST;
Inch = 40 Feet
____�
T2 = 530-Gallon UST
PROJECT:
George Linville Properly
CEDAR ROCK
INCIDENT #
A coo 4 -7-
ENVIRONMENTAL, P.C.
LOCATION:
800 Mohigan Street
FIGURE
1
Charlotte, Mecklenburg Co.
FILENAME: 2852NoRP.fc7
CRE PROJECT NUMBER: 285222590
VERSION DATE: 1/3/20
CEDAR ROCK ENVIRONMENTAL, P.C.
Cedar Rock 107 Pioneer Trail
Graham, NC 27253
ENVIRONMENTAL (336) 376-0394
January 24, 2020
Mr. Wade Chipps
703 Rollerton Road — Apt. 202
Charlotte, NC 28205
RE: Underground Storage Tank (UST) Closure Assessment Report
800 Mohigan Street, Charlotte, North Carolina
Cedar Rock Project Number 285222590
Dear Mr. Chipps:
Cedar Rock Environmental, P.C. (Cedar Rock) is pleased to submit this report describing activities
and results for the in -place abandonment of two USTs located at 800 Mohigan Street in Charlotte,
North Carolina. The UST abandonments were performed on January 22, 2020. Included in this
report are project documents consisting of a disposal manifest and photographic documentation.
This report should be kept with other documents pertaining to the residential property.
Both USTs were found to have leaked, and significant soil contamination was detected beneath
one of the USTs during a site inspection performed on December 19, 2019. The release was
reported to the Department of Environmental Quality (DEQ) using a UST-61 form on January 3,
2020. Although the State no longer requires further assessment of the contamination, the State
does require the filing of a Notice of Residual Petroleum (NRP) prior to conveying the property to
another party. The NRP includes land use restrictions prohibiting any disturbance of site soils
within a specified radius of the estimated extent of soil contamination, and prohibits the use or
installation of any water supply wells on the property. Cedar Rock filed the NRP on January 14,
2020. The DEQ will issue a Conditional Notice of No Further Action (NFA) letter within the next
few days. Upon receipt of proof that the local officials and adjacent property owners have been
notified of the release by receiving a copy of the Conditional NFA letter, and that the NRP has
been filed, the DEQ will reissue the NFA letter with no conditions to officially close out the
petroleum release incident.
Enclosed is an invoice for this work effort. If you have any questions, please do not hesitate to
contact me at 336-376-0394. Thank you for your consideration of Cedar Rock to provide you with
this service.
Sincerely,
Robert A. Payne, L.G.
President
RAP:rp
Attachments
UNDERGROUND STORAGE TANK
CLOSURE ASSESSMENT REPORT FOR
800 MOHIGAN STREET
CHARLOTTE, NORTH CAROLINA
Prepared for:
Mr. Wade Chipps
Charlotte, North Carolina
Prepared by:
Cedar Rock Environmental, P.C.
107 Pioneer Trail
Graham, North Carolina
Robert A. Payne, L.G.
President
January 24, 2020
CR #285222590
Section
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 PROJECT
FIGURE
Site Map
APPENDICES
A Fluid Disposal Manifest
B Photographic Documentation
Pam
I hereby certify this 24th day of January 2020 that this report was prepared by me or under my
direct supervision.
� YC A
t SEALS°°"
0970 #
Robert A. Payne, L.G.
Geologist
ii
1.0 INTRODUCTION
Cedar Rock Environmental, P.C. (Cedar Rock) was contacted by Mr. Wade Chipps of Charlotte,
North Carolina to abandon in -place two underground storage tanks (USTs) located at 800 Mohigan
Street in Charlotte, North Carolina. The USTs were first inspected on December 19, 2019. An
inactive UST (T I) was discovered to be located parallel to and centered approximately 4.3 feet off
the northwest foundation wall and about 10 feet southwest of the northern foundation corner of
the house. Both the fill and vent pipes of T 1 were observed to be intact. The depth to the top of
the UST is approximately 18 inches below land surface (bls). The UST has a length of about 75
inches with a diameter of approximately 46 inches and a capacity of about 540 gallons. The UST
was measured to contain approximately 181 gallons of fluid. White flagging was installed to mark
the ends of the UST.
Once the orientation of the UST (TI) was determined, two soil borings were performed, one at
each end of the UST using a 3.25-inch diameter stainless steel hand auger. The soil boring at the
northeast end of the T 1 was advanced to a depth of approximately 6.6 feet bls, about 1.3 feet below
the bottom of the UST. No soil contamination was observed in this boring. A second soil boring
was performed at the opposite end of T1. A slight petroleum odor was observed at a depth of
approximately 4.8 feet and exhibited local discoloration indicating that some tank leakage had
occurred. The soil at the base of the boring at a depth of 6.6 feet bls exhibited no petroleum odor
suggesting T 1 is in the early stages of leakage but has not yet significantly impacted the underlying
soils. The native soil underlying T 1 consists of a reddish -brown sandy silt.
A metal detector was used to survey the outside perimeter of the house where USTs are most likely
to be located. In such manner, a second UST (T2) was discovered to be located parallel to and
centered approximately 6.0 feet off the southwest foundation wall and about 11.2 feet southeast of
the western foundation corner of the house. Both the fill and vent pipes of T2 were missing. The
depth to the top of T2 is approximately 19 inches below land surface (bls). The UST has a length
of about 98 inches. No access was available to measure tank contents on December 19, 2019.
White flagging was installed to mark the ends of the UST. UST T2 is likely to be the original UST
installed with the oil heat system. UST T 1 would probably have been installed to replace T2 when
it began to take on water through corrosion holes in the UST. During abandonment activities on
January 22, 2020, the diameter of T2 was measured to be approximately 42 inches giving a
capacity of about 590 gallons, and it was measured to contain approximately 20 gallons of fluid.
Once the orientation of the UST (T2) was determined, a single soil boring was performed at the
northwest end of the UST. The soil boring was advanced to a depth of approximately 6.8 feet bls,
about 1.9 feet below the estimated bottom of the UST. A moderate petroleum odor was observed
in the soils from a depth of approximately 5.0 to 6.8 feet bls suggesting the UST has significantly
impacted the underlying soils. The native soil underlying T2 consists of a light brown sandy silt.
2.0 PROJECT
The in -place abandonments of the USTs were performed on January 22, 2020. The abandonments
consisted of the hand excavation of the soils overlying the northeastern end of T1, and the
northwestern end of T2, to expose the topside of each tank. A hole approximately 1.5 feet in
1
diameter was then cut on the top of each UST to allow for removal of the tank contents, cleaning
and visual inspection of the UST interior, and subsequent filling. Each tank was pressure washed
to remove all residual petroleum sludge. Residual oil in the fuel lines was also removed by
vacuum. The fuel lines were cut and crimped closed at the foundation wall of the crawlspace area.
A total of approximately 243 gallons of fluid and sludge (including rinsate) were removed from
the two USTs. The fluid disposal manifest for the tank contents is included in Appendix A.
After the interior of each UST was cleaned, each tank was then entirely filled with an excavatable
flowable fill cement slurry. Once filled, the exposed portion of each UST was then covered with
site soils (see Appendix B - Photographic Documentation).
2
FIGURE
SITE MAP
0 5 10 20
T1 = 540-Gallon UST;
1 Inch = 10 Feet T2 = 590-Gallon UST
PROJECT: George Linville Property
INCIDENT # 40972
LOCATION: 800 Mohigan Street
Charlotte Mecklenburg Co.
CRE PROJECT NUMBER: 285222590
CEDAR ROCK
ENVIRONMENTAL, P.C.
FILENAME: 2852-Figl.fc7
VERSION DATE: 1/23/20
SITE MAP
FIGURE 1
APPENDIX A
FLUID DISPOSAL MANIFEST
MATERIAL 40''` Manifest Document No.
ebia
MANIFEST ---�-- Page of
EnvuonmenfalB lnduslsial Se/vites l
EMERGENCY PHONE NO. POST OFFICE BOX 357 TEL (336) 841-5276 Zebra Job No.
(336) 841-5276 HIGH POINT, NC 27261 FAX (336) 841-5509
GENERATOR INFORMATION
Name � US EPA ID No.
Street Address Mailing Address Phone No.
�(Oo I-qo t i !jq'i �5 Contact
DESCRIPTION OF MATERIALS
USDOT Proper Shipping Name
HMI (Complete All Items for Hazardous Materials)
Hazard
Class or Div
UN I NA
ID No.
Packing
Group
Containers
Qty. Type
Total
Quantity
Unit
Wt.Nol.
a.
b.
c.
ADDITIONAL INFORMATION
ERG No.
Zebra Profile Code
Facility Use
a.
b.
C.
GENERATOR'S CERTIFICATION
This is to certify that the above -described materials are properly classified, described, packaged, marked and labeled, and are in
proper condition for transportation according to the applicable regulations of the Department of Transportation. 1 further certify that
none of the materials described above are a hazardous waste as defined by EPA 40 CFR Part 261 or any applicable state law, and
unless specifically identified above, the materials contain less than 1, 000 ppm total halogens and do not contain quantifiable levels
(2 ppm) of PCBs as defined by EPA 40 CFR Parts 279 and 761.
Printed,) Typed Name Signature ){ Mo. I Day ! Yr.
TRANSPORTER
INFORMATION
Transporter Zebra Environmental & Industrial Services Inc
I hereby acknowledge receipt of the above -described materials for transport
from the generator site listed above.
Address
901 East Springfield Road
High Point, NC 27263
Signature - Shipment Date
I hereby acknowledge receipt of the above -described materials were received
from the generator site and were transported to the facility listed below.
Transporter or NC0991302669
Unit NT
{ --
EPA ID NO.
V nC
Signature Delivery Date
Phone (336) 841-5276
FACILITY INFORMATION
Facility Zebra Environmental & Industrial Services, Inc.
thereby acknowledge receipt of the materials covered by this manifest
except for any discrepancy noted below.
Address
901 East Springfield Road
High Point, NC 27263
Signature Receipt Date
Discrepancies i Routing Codes i Handing Methods
Facility or NCO991302669
EPA ID No.
a'
Phone (336)841-5276
b'
Contact gill Hunter
C.
ORIGINAL - Facility Retain COPY 2 -Return to Generator COPY 3 -Transporter Retain COPY 4 - Generator Retain
APPENDIX B
PHOTOGRAPHIC DOCUMENTATION
T -T
Y4 8m \
p
M1��l1 '.. �r n /, tie ��/ � . �1i' - � p ' .rt� �'h'+'�c-`�it;�•' ,�i, � .<
Photo 3. View of UST Tl interior after the removal of UST contents and
pressure wash cleaning of the tank interior.
n
.A
Photo 4. View of UST T1 being filled with flowable fill cement slurry.
Photo 5. View of UST T 1 after filling with flowable fill cement slurry.
Photo 6. View of UST T1 site after the completion of abandonment activities.
Photo 7. View of UST T2 site prior to abandonment activities.
Photo 8. View of UST T2 interior prior to the removal of tank contents.
Photo 9. View of UST T2 interior after the removal of UST contents and
pressure wash cleaning of the tank interior.
Photo 10. View of UST T2 being filled with flowable fill cement slurry.
Photo 11. View of UST T2 after filling with flowable fill cement slurry.
Photo 12. View of UST T2 site after the completion of abandonment activities.
Beverly, Trudy
From: Beverly, Trudy
Sent: Friday, January 24, 2020 9:55 AM
To: Bob Payne
Subject: RE: [External] Documents for the George Linville property, 800 Mohigan Street,
Charlotte
Received.
Trudy
Trudy Beverly, L.G.
D-�IE Hydrogeologist, Division of Waste Management
North Carolina Department of Environmental Quality
IFepnrlren[ol Gma'nn mental4w
UST Section, Mooresville Regional Office
704.235.2182 (Office)
Trudy. B everlykncdenr. gov
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Office Mailing Address:
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: hit2s://deq.nc.gov/about/divisions/waste-management/ust/ast-program
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
httns://dea.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-mans
File Review Procedures:
hops://deq.ne. gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
fts://deq.nc.gov/about/divisions/waste-manaizement/laserfiche
Document Submittal & UST File Names for Laserfiche Policies:
https:Hfiles.nc.gov/ncdeq/Waste%2OManagement/D WMIUST/Corrective%2OAction/Electronic%2ODocument%2OSubmittal%2OMemo%2OUpdate.pdf
https:Hfiles.nc. gov/ncdeq/Waste%2OManagement/DWM/UST/Corrective%2OAction/UST%2Ofile%20names%20for%2OLaserfiche.docx
From: Bob Payne [mailto:cedarrockenv@gmail.com]
Sent: Friday, January 24, 2020 6:50 AM
To: Beverly, Trudy <trudy.beverly@ncdenr.gov>
Subject: [External] Documents for the George Linville property, 800 Mohigan Street, Charlotte
External email. Do not click links or open attachments unless you verify. Send all suspicious email as an
attachment to report.spam@nc.gov
Good morning Trudy. Please see the attached report and NRP. Let me know if you need anything else for
issuance of the Conditional NFA letter. Thank you,
Robert A. Payne, L. G.
(cell) 336-684-2734
gtl�Cedar Rock
ENVIRONMENTAL
Jeremiah 9:23-24