Loading...
HomeMy WebLinkAbout22001_South Graham Tower EMP FINAL 20181212 1 EMP Version 2, June 2018 NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the North Carolina Brownfields Program at the direction of a Brownfields project manager. The EMP is a typical requirement of a Brownfields Agreement (BFA). Its purpose is to clarify actions to be taken during the demolition and construction at Brownfields properties in an effort to avoid delays in the event of the discovery of new contamination sources or other environmental conditions. The EMP provides a means to document redevelopment plans and environmental data for each applicable environmental medium to inform regulatory-compliant decision-making at the site. As much detail as possible should be included in the EMP, including contingency planning for unknowns. Consult your project manager if you have questions. Prospective Developers and/or their consultants must complete and submit this form and all pertinent attachments, see checklist below, to their Brownfields project manager prior to any earthmoving or other development-related activities that have the potential to disturb soil at the Brownfields Property, including demolition. For the resultant EMP to be valid for use, it must be completed, reviewed by the program, signed by all parties working on the project, and approved by the Brownfields project manager. Failure to comply with the requirements of the EMP could jeopardize project eligibility, or in the event of a completed agreement, be cause for a reopener So that the EMP provides value in protecting brownfields eligibility and public health, the preparer shall ensure that the following steps have been completed prior to submitting the EMP for review. Any EMP prepared without completing these steps is premature. ☐ Site sampling and assessment that meets Brownfields’ objectives is complete and has been reviewed and approved by the Brownfields Project Manager. ☐ Specific redevelopment plans, even if conceptual, have been developed for the project, submitted and reviewed by the Brownfields Project Manager. 2 EMP Version 2, June 2018 Please submit, along with the completed EMP form, the following attachments, as relevant and applicable to the proposed redevelopment: ☒ A set of redevelopment plans, including architectural/engineering plans, if available; if not conceptual plans may suffice if updated when detailed plans are drafted. ☒ A figure overlaying redevelopment plans on a map of the extent of contamination for each media. ☒ Site grading plans that include a cut and fill analysis. ☐ A figure showing the proposed location and depth of impacted soil that would remain on site after construction grading. ☐ Any necessary permits for redevelopment (i.e. demolition, etc.). ☒ A detailed construction schedule that includes timing and phases of construction. ☒ Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas, etc.) applicable to the proposed redevelopment. ☒ Figures with the sampling locations and contamination extents for each impacted media applicable to the proposed redevelopment. ☐ A full final grade sampling and analysis plan, if the redevelopment plan is final. ☐ If known, information about each proposed potential borrow soil source, such as aerial photos, historic site maps, historic Sanborn maps, a site history, necessary for brownfields approval. ☐ Information and, analytical data if required, for quarries, or other borrow sources, detailing the type of material proposed for importation to the Brownfields Property. ☐ A work plan for the sampling and analysis of soil to be brought onto the Brownfields Property. Refer to Issue Resolution 15 in Brownfields Program Guidelines. ☒ A map of the Brownfields Property showing the location of soils proposed for export and sampling data from those areas. ☒ If a Vapor Mitigation System is required by the Brownfields Program, the Vapor Intrusion Mitigation System (VIMS) plan will be signed and sealed by a NC Professional Engineer. The VIMS Plan may also be submitted under separate cover. 3 EMP Version 2, June 2018 GENERAL INFORMATION Date: 11/20/2018 Revision Date (if applicable): 12/11/2018 Brownfields Assigned Project Name: 401 South Graham Street Brownfields Project Number: 22001-18-060 Brownfields Property Address: 401 South Graham Street, Charlotte, Mecklenburg County Brownfields Property Area (acres): 0.673 Is Brownfields Property Subject to RCRA Permit?.......................☐ Yes ☒ No If yes enter Permit No.: Click or tap here to enter text. Is Brownfields Property Subject to a Solid Waste Permit….……..☐ Yes ☒ No If yes, enter Permit No.: Click or tap here to enter text. COMMUNICATIONS A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the EMP shall be maintained at the Brownfields Property during redevelopment activities. NOTE, THE EMP DOES NOT TAKE THE PLACE OF A SITE-SPECIFIC HEALTH AND SAFETY PLAN. Prospective Developer (PD): Dominion Realty Partners, LLC Contact Person: Robert “Beau” McIntosh Phone Numbers: Office: (704) 877-5681 Mobile: (704) 877-5681 Email: BMcIntosh@drp-llc.com Contractor for PD: Batson-Cook Construction Contact Person: David Hamilton Phone Numbers: Office: (704)790-4003 Mobile: (904) 759-1096 Email: dhamilton@batson-cook.com Environmental Consultant: S&ME, Inc. Contact Person: Roger A. Smith, P.G. Phone Numbers: Office: (704) 523-4726 Mobile: (704) 840-7279 Email: rsmith@smeinc.com Brownfields Program Project Manager: William Schmithorst Phone Numbers: Office: (919) 707-8159 Mobile: Click or tap here to enter text. Email: william.schmithorst@ncdenr.gov Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch, 4 EMP Version 2, June 2018 Hazardous Waste, Solid Waste): Click or tap here to enter text. NOTIFICATIONS TO THE BROWNFIELDS PROGRAM Written advance Notification Times to Brownfields Project Manager: Check each box to accept minimum advance notice periods (in calendar days) for each type of onsite task: On-site assessment or remedial activities:……………………………………….…… 10 days Prior ☒ Construction or grading start:……………………………………….………………………. 10 days Prior ☒ Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously unknown contamination: ……………………………….……………………………………. Within 48 hours ☒ Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in area of contamination, ventilation of work zones):…………….……….……… Within 48 hours ☒ Installation of mitigation systems:………………………….………………….……….. 10 days Prior ☒ Other notifications as required by local, state or federal agencies to implement redevelopment activities: (as applicable): ……………………….…………………………………………..… Within 30 days ☒ REDEVELOPMENT PLANS 1) Type of Redevelopment (check all that apply): ☒Residential ☐Recreational ☐Institutional ☒Commercial ☒Office ☒Retail ☐Industrial ☐Other specify: Click or tap here to enter text. 2) Check the following activities that will be conducted prior to commencing earth-moving activities at the site: ☒ Review of historic maps (Sanborn Maps, facility maps) ☐ Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc. ☐ Interviews with employees/former employees/facility managers/neighbors 3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if detailed plans are not available. EMP review without such information would be premature): Provide brief summary of redevelopment plans, including demolition, removal of building slabs/pavement, grading plans and planned construction of new structures: The site currently consists of an asphalt and gravel covered parking lot (See Figure 2 for current 6 EMP Version 2, June 2018 Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. d) Provide the planned date of occupancy for new buildings: 1/1/2021 CONTAMINATED MEDIA 1) Contaminated Media on the Brownfields Property Part 1. Soil:……………………………………….……………. ☐ Yes ☒ No ☐ Suspected Part 2. Groundwater:.……………………….……..……. ☒ Yes ☐ No ☐ Suspected Part 3. Surface Water:.……………...……..…………… ☐ Yes ☒ No ☐ Suspected Part 4. Sediment:.……………...……..…………………… ☐ Yes ☒ No ☐ Suspected Part 5. Soil Vapor:…..…………...……..…………………. ☒ Yes ☐ No ☐ Suspected Part 6. Sub-Slab Soil Vapor:……...……..…………….. ☐ Yes ☒ No ☐ Suspected Part 7. Indoor Air:...……..…………………………………. ☐ Yes ☒ No ☐ Suspected 2) For the Area of Proposed Redevelopment on the Brownfields Property, attach tabulated data summaries for each impacted media and figure(s) with sample locations. PART 1. Soil – Please fill out the information below, using detailed site plans, if available, or estimate using known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new construction onto figure showing contaminated soil and groundwater locations. 1) Known or suspected contaminants in soil (list general groups of contaminants): No soil contamination has been identified at the site above the groundwater. During previous soil sampling events, conducted in proposed excavations areas, only arsenic was detected at concentrations greater than the Residential Preliminary Soil Remedial Goals (PSRGs); however, the concentrations appear to be naturally occurring and not a result of a release. Therefore, excavated soils above groundwater are not considered to be contaminated. (See Figure 3 for sample locations, Table 1 for summary of soil sample results and Figure 4 for PSRG exceedances) Soils removed from below groundwater are considered to be contaminated with VOCs, due to groundwater impacts. Soils removed from below the groundwater will either be direct loaded into trucks and transported offsite for permitted disposal, or will be stockpiled onsite, on plastic, 7 EMP Version 2, June 2018 secured, and covered until they can be loaded into trucks and transported offsite for permitted disposal. (See Table 2 for summary of groundwater sample results and Figure 4 for groundwater sample locations and exceedances) In order to assess removed soils for evidence of contamination, the environmental consultant will periodically visit the site during excavation activities to screen soils and worker’s breathing zones for apparent impacts using field observations and screening with either of Photoionization Detector (PID) or Flame Ionization Detector (FID). 2) Depth of known or suspected contaminants (feet): Soils below groundwater, anticipated to be below mean sea level elevation of approximately 700 to 702 feet. 3) Area of soil disturbed by redevelopment (square feet): Total Estimated volume of soils to be removed is approximately 7,000 cubic yards 4) Depths of soil to be excavated (feet): Varies 5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan): Total volume of soils to be excavated for foundations are less than 7,000 cubic yards 6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants: Less than 1,000 cubic yards (i.e., soils below groundwater) 7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: 1,000 cubic yards (i.e., all soils excavated below groundwater). However, due to no space available onsite for reuse of any soils (impacted or not impacted), all soils will be exported offsite for disposal. Part 1.A. MANAGING ONSITE SOIL If soil is anticipated to be excavated from the Brownfield Property, relocated on the Brownfields Property, or otherwise disturbed during site grading or other redevelopment activities, please provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are acceptable, if only preliminary data available). 1) HAZARDOUS WASTE DETERMINATION: a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous Waste Section under 40 CFR Part 261.31-261.35?....................................... ☐Yes ☒No ☐ If yes, explain why below, including the level of knowledge regarding processes generating the waste (include pertinent analytical results as needed). Click or tap here to enter text. 8 EMP Version 2, June 2018 ☐ If yes, do the soils exceed the “Contained-Out” levels in Attachment 1 of the North Carolina Contained-In Policy?................................................. ☐ Yes ☒ No b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE CONTAINED-OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED-IN POLICY THE SOIL MAY NOT BE RE-USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. c) Does the soil contain a CHARACTERISTIC WASTE?.................................... ☐ Yes ☒ No ☐ If yes, mark reason(s) why below (and include pertinent analytical results). ☐ Ignitability Click or tap here to enter text. ☐ Corrosivity Click or tap here to enter text. ☐ Reactivity Click or tap here to enter text. ☐ Toxicity Click or tap here to enter text. ☐ TCLP results Click or tap here to enter text. ☐ Rule of 20 results (20 times total analytical results for an individual hazardous constituent on TCLP list cannot, by test method, exceed regulatory TCLP standard) Click or tap here to enter text. ☒ If no, explain rationale: Based on historical laboratory results, site soils are not likely to contain characteristic waste. d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAY NOT BE RE-USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. 2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in place with low permeability barrier, removed to onsite location and capped, removed offsite): ☐ Preliminary Health-Based Residential SRGs ☐ Preliminary Health-Based Industrial/Commercial SRGs ☐ Division of Waste Management Risk Calculator (For Brownfields Properties Only) ☐ Site-specific risk-based cleanup level. Please provide details of methods used for determination/explanation. Click or tap here to enter text. Additional comments: 9 EMP Version 2, June 2018 Soils excavated at the site during construction will be disposed offsite. Excavated soils (above and below the impacted groundwater) will be either directly loaded into trucks and transported offsite for disposal at landfill or temporarily stockpiled onsite, on plastic, secured and covered until such time as they can be loaded and transported offsite for disposal. Soils excavated at the site will be transported to one or more of the following permitted landfills for disposal at Republic Services in Concord, North Carolina or at EVO in Winston Salem, NC. 3) If known impacted soil is proposed to be reused within the Brownfields Property Boundary, please check the measures that will be utilized to ensure safe placement and documentation of same. Please attach a proposed location diagram/site map. ☐ Provide documentation of analytical report(s) to Brownfields Project Manager ☐ Provide documentation of final location, thickness and depth of relocated soil on site map to Brownfields Project Manager once known ☐ Geotextile to mark depth of fill material. Provide description of material: Click or tap here to enter text. ☐ Manage soil under impervious cap ☐ or clean fill ☐ ☐ Describe cap or fill: Click or tap here to enter text. ☐ Confer with NC BF Project Manager if Brownfield Plat must be revised (or re-recorded if actions are Post-Recordation). ☐ GPS the location and provide site map with final location. ☒ Other. Please provide a description of the measure: 4) Please describe the following action(s) to be taken during and following excavation and management of site soils: Management of fugitive dust from site ☒ Yes, describe the method will include: Typical construction dust control measures will be utilized such as wetting with water trucks or hoses to manage nuisance dust levels. ☐ No, explain rationale: Click or tap here to enter text. Field Screening of site soil ☒ Yes, describe the field screening method, frequency of field screening, person conducting field screening: During soil disturbance, the workers or contractors will observe soils for evidence of All impacted soils that are excavated during construction will be transported offsite for disposal at a permitted landfill. 10 EMP Version 2, June 2018 distinct unnatural color, strong odor, or fill materials of concern (i.e., chemicals, tanks, drums, subsurface piping, etc.). Should the above be noted during site work, the contractor will contact the project environmental consultant to observe the suspect condition. Additionally, the environmental consultant will periodically visit the site during excavation activities to observe and periodically assess soils for evidence of apparent impacts. If the environmental consultant confirms that the material may be impacted (using field observations and screening with PID/FID), then the soils will be managed in accordance with this EMP and the NCDEQ, BF Project Manager will be contacted within 48 hours to advise of the condition. ☐ No, explain rationale: Click or tap here to enter text. Soil Sample Collection ☐ Yes, describe the sampling method (e.g., in-situ grab, composite, stockpile, etc.): . ☒ No, explain rationale: Laboratory analysis of soil samples collected above the groundwater table in areas to be excavated did not identify impacted soils at concentrations greater than the Residential PSRGs, except for arsenic, which is likely natural occurring concentration. Therefore, impacted soils are not anticipated. However, should impacted soils be encountered during redevelopment, they will be addressed as stated in No. 5 - “Field Screening”, above. If soil samples are collected for analysis, please check the applicable chemical analytes: ☒ Volatile organic compounds (VOCs) by EPA Method 8260 ☐ Semi-volatile organic compounds (SVOCs) by EPA Method 8270 ☐ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Specify Analytical Method Number(s): Click or tap here to enter text. ☒ Check to confirm that stockpiling of known or suspected impacted soils will be conducted 11 EMP Version 2, June 2018 in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion control, prohibiting contact between surface water/precipitation and contaminated soil, and preventing contaminated runoff. Explain any variances or provide additional details as needed: ☐ Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or permanent hardscape). Select chemical analyses for final grade samples with check boxes below (Check all that apply): ☐ Volatile organic compounds (VOCs) by EPA Method 8260 ☐ Semi-volatile organic compounds (SVOCs) by EPA Method 8270 ☐ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Click or tap here to enter text. Please provide a scope of work for final grade sampling, including a diagram of soil sampling locations, number of samples to be collected, and brief sampling methodology. Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs which should be taken from 1-2 ft below ground surface. Alternatively, a work plan for final grade sampling may be submitted under separate cover. Click or tap here to enter text. ☒ If final grade sampling was NOT selected please explain rationale: No final grade sampling is proposed since no contaminated soils were identified at the site above the groundwater table. Additionally, only limited soils will be exposed at the site after construction is completed and those areas will be within landscaped areas. Part 1.B. IMPORTED FILL SOIL NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL FROM THE BROWNFIELDS PROGRAM. According to the Brownfields IR 15, “Documenting imported soil (by sampling, analysis, and reporting in accordance with review and written approval in advance by the Brownfields Program), will safeguard the liability protections provided Click or tap here to enter text. 12 EMP Version 2, June 2018 by the brownfields agreement and is in the best interest of the prospective developer/property owner.” Requirements for importing fill: 1) Will fill soil be imported to the site?................................................ ☐ Yes ☒ No ☐ Unknown 2) If yes, what is the estimated volume of fill soil to be imported? Click or tap here to enter text. 3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range of depths, please list the range.) Click or tap here to enter text. 4) Provide the source of fill, including: location, site history, nearby environmental concerns, etc. Attach aerial photos, maps, historic Sanborn maps and a borrow source site history: Although no soils are anticipated to be imported to the site, should importing of soils be required, they will be acquired from Martin Marietta Quarry located at 4551 Beatties Ford Road in Charlotte, North Carolina. This quarry has previously been approved by the NCDEQ as a soils fill source for Brownfields site. 5) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide a plan to analyze fill soil to demonstrate that it meets acceptable standards applicable to the site and can be approved for use at the Brownfields property. Click or tap here to enter text. 6) Please check the applicable chemical analytes for fill soil samples. (Check all that apply): ☐ Volatile organic compounds (VOCs) by EPA Method 8260 ☐ Semi-volatile organic compounds (SVOCs) by EPA Method 8270 ☐ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Click or tap here to enter text. 7) The scope of work for import fill sampling may be provided below or in a Work Plan submitted separately for DEQ review and approval. Attach specific location maps for in-situ borrow sites. If using a quarry, provide information on the type of material to be brought 13 EMP Version 2, June 2018 onto the Brownfields Property. Click or tap here to enter text. Part 1.C. EXPORTED SOIL NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE BROWNFIELDS PROGRAM. FAILURE TO OBTAIN APPROVAL MAY VIOLATE A BROWNFIELDS AGREEMENT CAUSING A REOPENER OR JEOPARDIZING ELIGIBILITY IN THE PROGRAM, ENDANGERING LIABILITY PROTECTIONS AND MAKING SAID ACTION POSSIBLY SUBJECT TO ENFORCEMENT. JUSTIFICATIONS PROVIDED BELOW MUST BE APPROVED BY THE PROGRAM IN WRITING PRIOR TO COMPLETING TRANSPORT ACTIVITIES. Please refer to Brownfields IR 15 for additional details. 1) If export from a Brownfields Property is anticipated, please provide details regarding the proposed export actions. Volume of exported soil, depths, location from which soil will be excavated on site, related sampling results, etc. Provide a site map with locations of export and sampling results included. Although the only soils removed below groundwater are considered to be impacted, since there is no available areas of the site to allow reuse of any excavated soils, all soils excavated from the site for foundations will be exported, which is anticipated to be approximately 7,000 cubic yards or less. The excavated soils will either be direct loaded into trucks and transported offsite for permitted disposal, or will be stockpiled onsite, on plastic, secured, and covered until they can be loaded into trucks and transported offsite for permitted disposal. Should soils excavated below groundwater contain water at a sufficient amount that it leaches from the soils, even following dewatering activities, the soils will be contained (either on plastic, bermed and secured) to contain the groundwater until the soils are removed from the site for offsite disposal. Or, if the soils are directly loaded into trucks for offsite disposal, plastic will be placed in the bed of the trucks when soils are saturated, in order to contain any potential groundwater from exiting the truck during transport. The locations of the proposed excavations for the various foundations along with previous soil sampling locations are provided on Figure 5. 2) To what type of facility will the export Brownfields soil be sent? ☒ Subtitle D/Municipal Solid Waste Landfill (analytical program to be determined by landfill) ☐ Permitted but Unlined Landfill (i.e. LCID, C&D, etc.) Analytical program to be determined by the accepting Landfill; ☐ Landfarm or other treatment facility ☐ Use as fill at another suitable Brownfields Property – determination that a site is suitable will require, at a minimum, that similar concentrations of the same or similar contaminants already exist at both sites, use of impacted soil will not increase the potential for risk to human health and the environment at the receiving Brownfields property, and that a record of the acceptance of such soil from the property owner of 14 EMP Version 2, June 2018 the receiving site is provided to Brownfields. Please provide additional details below. ☐ Use as Beneficial Fill off-site at a non-Brownfields Property - Please provide documentation of approval from the property owner for receipt of fill material. This will also require approval by the DEQ Solid Waste Section. Additional information is provided in IR 15. Please provide additional details below. 3) Additional Details: (if transfer of soil to another property is requested above, please provide details related to the proposed plans). Click or tap here to enter text. Part 1.D. MANAGEMENT OF UTILITY TRENCHES ☐ Install liner between native impacted soils and base of utility trench before filling with clean fill (Preferred) ☐ Last out, first in principle for impacted soils (if soil can safely be reused onsite and is not a hazardous waste), i.e., impacted soils are placed back at approximately the depths they were removed from such that impacted soil is not placed at a greater depth than the original depth from which it was excavated. ☐ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or degradation of conduit materials due to direct impact with contaminants? ☐ If yes, provide specifications on barrier materials: Click or tap here to enter text. ☐ If no, include rationale here: Click or tap here to enter text. Other comments regarding managing impacted soil in utility trenches: Since contaminated soils have not been identified at the site, impacted soils in utility trenches are not anticipated. However, should impacted soils be identified, they will be managed as previously stated. PART 2. GROUNDWATER – Please fill out the information below. 1) What is the depth to groundwater at the Brownfields Property? Depending upon the ground surface location, the depth to groundwater at the site various from approximately 9 to 16 feet below grade. However, based on previous site investigations, ground is typically not encountered until a depth of approximately 20 feet, but over time, groundwater may rise to the depths of 9 to 16 feet, below current grade. 2) Is groundwater known to be contaminated by ☐onsite ☒offsite ☐both or ☐unknown sources? Describe source(s): 15 EMP Version 2, June 2018 The source of the groundwater contamination is not known, but is suspected to be from an offsite source. Figure 3 indicates the location of groundwater samples collected at the site, Table 2 summaries groundwater sample results, and Figure 4 indicates the locations of groundwater samples with contaminant exceedances. 3) What is the direction of groundwater flow at the Brownfields Property? Based on the USGS Topographic map, the groundwater is estimated to flow to the southwest toward a tributary of Irwin Creek. See Figure 1 for location and area topographic information. 4) Will groundwater likely be encountered during planned redevelopment activities? ☒Yes ☐No If yes, describe these activities: The areas of the site where deeper excavations are required, it is likely that groundwater may be encountered. Regardless of the answer; in the event that contaminated groundwater is encountered during redevelopment activities (even if no is checked above), list activities for contingent management of groundwater (e.g., dewatering of groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or sampling procedures). Groundwater will be dewatered and contained, then transported off-site for disposal at one of the following permitted facilities including Shamrock in Brown Summit, North Carolina or HazMat in Charlotte, North Carolina. 5) Are monitoring wells currently present on the Brownfields Property?.................☐Yes ☒No If yes, are any monitoring wells routinely monitored through DEQ or other agencies?..................................................................................................................☐Yes ☐No 6) Please check methods to be utilized in the management of known and previously unidentified wells. ☒ Abandonment of site monitoring wells in accordance with all applicable regulations. It is the Brownfields Program’s intent to allow proper abandonment of well(s) as specified in the Brownfields Agreement, except if required for active monitoring through another section of DEQ or the EPA. ☐ Location of existing monitoring wells marked ☐ Existing monitoring wells protected from disturbance ☐ Newly identified monitoring wells will be marked and protected from further disturbance until notification to DEQ Brownfields can be made and approval for abandonment is given. 7) Please provide additional details as needed: Please note, disturbance of existing site monitoring wells without approval by DEQ is not permissible. If monitoring wells are damaged and/or destroyed, DEQ may require that the PD be responsible for replacement of the well. Click or tap here to enter text. 16 EMP Version 2, June 2018 PART 3. SURFACE WATER -Please fill out the information below. 1) Is surface water present at the property? ☐ Yes ☒ No 2) Attach a map showing the location of surface water at the Brownfields Property. 3) Is surface water at the property known to be contaminated? ☐ Yes ☒ No 4) Will workers or the public be in contact with surface water during planned redevelopment activities? ☐ Yes ☒ No 5) In the event that contaminated surface water is encountered during redevelopment activities, or clean surface water enters open excavations, list activities for management of such events (e.g. flooding, contaminated surface water run-off, stormwater impacts): No streams or other surface waters are located on the site; however, should impacted surface water will be encountered, it will be managed and disposed as previously stated for groundwater (e.g., the water will be contained, then transported off-site for disposal along with removed groundwater).. PART 4. SEDIMENT – Please fill out the information below. 1) Are sediment sources present on the property? ☐ Yes ☒ No 2) If yes, is sediment at the property known to be contaminated: ☐ Yes ☐ No 3) Will workers or the public be in contact with sediment during planned redevelopment activities? ☐ Yes ☒ No 4) Attach a map showing location of known contaminated sediment at the property. 5) In the event that contaminated sediment is encountered during redevelopment activities, list activities for management of such events (stream bed disturbance): No streams were identified on the site and no contaminated sediment are anticipated. However should impacted sediment be contained, then the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential sampling, reporting, and disposal requirements. PART 5. SOIL VAPOR – Please fill out the information below. 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the following vapor intrusion screening levels (current version) in the following media: 17 EMP Version 2, June 2018 IHSB Residential Screening Levels: Soil Vapor:………..☒ Yes ☐ No ☐ Unknown Groundwater:.….☒ Yes ☐ No ☐ Unknown IHSB Industrial/Commercial Screening Levels: Soil Vapor:………..☐ Yes ☐ No ☐ Unknown Groundwater:…..☒ Yes ☐ No ☐ Unknown 2) Attach a map showing the locations of soil vapor contaminants that exceed site screening levels. 3) If applicable, at what depth(s) is soil vapor known to be contaminated? 4) Will workers encounter contaminated soil vapor during planned redevelopment activities? ☐ Yes ☐ No ☒ Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities (trenches, manways, basements or other subsurface work,) list activities for management of such contact: If soil vapors be encountered, all work will cease in that area until the area can be assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting, and mitigation PART 6. SUB-SLAB SOIL VAPOR – Please fill out the information below if existing buildings or foundations will be retained in the redevelopment. 1) Are sub-slab soil vapor data available for the Brownfields Property? ☐ Yes ☒ No ☐ Unknown 2) If data indicate that sub-slab soil vapor concentrations exceed screening levels, attach a map showing the location of these exceedances. 3) At what depth(s) is sub-slab soil vapor known to be contaminated? ☐0-6 inches ☐Other, please describe: No structures are currently located on the site. 4) Will workers encounter contaminated sub-slab soil vapor during planned redevelopment activities? ☐ Yes ☒ No ☐ Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities, list activities for management of such contact No structures are currently located on the site, therefore no sub-slab soil vapors are anticipated. Approximately 5 feet below current grade. Figure 3 indicates the location of soil gas samples collected below the planned occupied spaces of the proposed site building, Table 3 includes a summary of the soil gas sample results, and Figure 4 indicates the sample locations and concentrations exceeding residential soil gas screening levels. 18 EMP Version 2, June 2018 However, should sub-slab soil vapors be encountered, all work will cease in that area until the area can be assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting, and mitigation. PART 7. INDOOR AIR – Please fill out the information below. 1) Are indoor air data available for the Brownfields Property? ☐ Yes ☒ No ☐ Unknown 2) Attach a map showing the location(s) where indoor air contaminants exceed site screening levels. 3) If the structures where indoor air has been documented to exceed risk-based screening levels will not be demolished as part of redevelopment activities, will workers encounter contaminated indoor air during planned redevelopment activities? ☐ Yes ☒ No ☐ Unknown 4) In the event that contaminated indoor air is encountered during redevelopment activities, list activities for management of such contact: VAPOR INTRUSION MITIGATION SYSTEM – Please fill out the information below. Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property? ☒ Yes ☐ No ☐ Unknown If yes, ☐ VIMS Plan Attached or ☒ VIMS Plan to be submitted separately If submitted separately provide date: The VIMS is currently prepared in draft format awaiting approval with the architect. It is estimated that the VIMS will be submitted under a separate cover to NCDEQ, BF, before construction begins, or on/or about December 15, 2018. The VIMS will be signed and sealed by a NC Professional Engineer. VIMS Plan shall be signed and sealed by a NC Professional Engineer If no, please provide a brief rationale as to why no vapor mitigation plan is warranted: Click or tap here to enter text. No structures are currently located on the site, therefore no indoor air vapors are anticipated. However, should indoor air vapors be encountered, all work will cease in that area until the area can be assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting, and mitigation. 19 EMP Version 2, June 2018 CONTINGENCY PLAN – encountering unknown tanks, drums, or other waste materials In this section please provide actions that will be taken to identify or manage unknown potential new sources of contamination. During redevelopment activities, it is not uncommon that unknown tanks, drums, fuel lines, landfills, or other waste materials are encountered. Notification to DEQ Brownfields Project Manager, UST Section, Fire Department, and/or other officials, as necessary and appropriate, is required when new potential source(s) of contamination are discovered. These Notification Requirements were outlined on Page 1 of this EMP. Should potentially impacted materials be identified that are inconsistent with known site impacts, the DEQ Brownfields Project Manager will be notified and a sampling plan will be prepared based on the EMP requirements and site-specific factors. Samples will generally be collected to document the location of the potential impacts. Check the following chemical analysis that are to be conducted on newly identified releases: ☒ Volatile organic compounds (VOCs) by EPA Method 8260 ☒ Semi-volatile organic compounds (SVOCs) by EPA Method 8270 ☒ Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver) Click or tap here to enter text. ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.) Please note, if field observations indicate the need for additional analyses, they should be conducted, even if not listed here. Click or tap here to enter text. Please provide details on the proposed methods of managing the following commonly encountered issues during redevelopment of Brownfields Properties. Click or tap here to enter text. Underground Storage Tanks: Should underground storage tanks be encountered, all work will cease in that area until the area can be assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting and mitigation. Sub-Grade Feature/Pit: Should sub-grade feature/pit be encountered, all work will cease in that area until the area can be 20 EMP Version 2, June 2018 assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting and mitigation. Buried Waste Material: Should buried waste material be encountered, all work will cease in that area until the area can be assessed by the environmental consultant. Should assessment confirm the presence of contaminants, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting and mitigation. Re-Use of Impacted Soils On-Site: Due to limited site space, re-use of any soils onsite is not anticipated; however, should re-use of impacted soils on-site occur, the NCDEQ, BF Project Manager will be notified within 48 hours and consulted as to potential further sampling, reporting and mitigation. If unknown, impacted soil is identified on-site, management on-site can be considered after the project team provides the necessary information, outlined in Part 1.A. Item 11, for Brownfields Project Manager approval prior to final placement on-site. If other potential contingency plans are pertinent, please provide other details or scenarios as needed below: Click or tap here to enter text. POST-REDEVELOPMENT REPORTING ☒ Check this box to acknowledge that a Redevelopment Summary Report will be required for the project. If the project duration is longer than one year, an annual update is required and will be due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of this EMP (as agreed upon with the Project Manager). These reports will be required for as long as physical redevelopment of the Brownfields Property continues, except that the final Redevelopment Summary Report will be submitted within 90 days after completion of redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary Report is anticipated to be submitted on 1/31/2020 The Redevelopment Summary Report shall include environment-related activities since the last report, with a summary and drawings, that describes: 1. actions taken on the Brownfields Property; 2. soil grading and cut and fill actions; 3. methodology(ies) employed for field screening, sampling and laboratory analysis of environmental media; 21 EMP Version 2, June 2018 4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and ultimate disposition of any soil, groundwater or other materials suspected or confirmed to be contaminated with regulated substances; and 5. removal of any contaminated soil, water or other contaminated materials (for example, concrete, demolition debris) from the Brownfields Property (copies of all legally required manifests shall be included). ☒ Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment Summary Report in compliance with the site’s Brownfields Agreement. 12/14/2018 Attachments 22 EMP Version 2, June 2018 Attachment I – Figures ^_ ^_Project Location SCALE: DATE: PROJECT NUMBER FIGURE NO. 11 " = 2,000 ' 11-20-18 4335-17-154B GRAHAM TOWER SITE401 S. GRAHAM STREETCHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINADrawing Path: Q:\4335\17\154 Graham and MLK Tower\1_vicinityB.mxd plotted by DHomans 11-20-20180 2,000 4,000(FEET) SITE LOCATION MAP ³ REFERENCE: USGS USA TOPO STREAMING DATASETGIS BASE LAYERS WERE OBTAINED FROM THE NATIONAL MAP. THIS MAP IS FORINFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED.THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. Service Layer Credits: USGS The National Map: NationalBoundaries Dataset, 3DEP Elevation Program, GeographicNames Information System, National Hydrography S Graham StS Graham StW Martin Luther King Jr Bv Project Parcel SCALE: DATE: PROJECT NUMBER FIGURE NO. 21 " = 50 ' 11-20-18 4335-17-154B GRAHAM TOWER SITE401 S. GRAHAM STREETCHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINADrawing Path: Q:\4335\17\154 Graham and MLK Tower\02_AERIAL.mxd plotted by DHomans 11-20-20180 50 100(FEET) 2018 AERIAL PHOTOGRAPH ³ REFERENCE: 2018 AERIAL PHOTOGRAPHGIS BASE LAYERS WERE OBTAINED FROM MECKLENBURG COUNTY GIS. THIS MAP IS FORINFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED.THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. Service Layer Credits: meckco !´Ð !´Ð !´Ð Ð"I Ð"I Ð!G Ð!G Ð!G Ð!G Ð!G Ð!GÐ!G Ð!GS Graham StW Martin Luther King Jr Bv TW-1 TW-2 TW-3 SG-1 SG-2 B-7 B-6 B-8 B-4 B-3 B-2B-1 B-5 Ð"I Soil Gas Sample Locations Ð!G Soil Sample Locations !´Ð Groundwater Sample Locations Proposed Occupied Area Project Parcel SCALE: DATE: PROJECT NUMBER FIGURE NO. 31 " = 30 ' 11-20-18 4335-17-154B GRAHAM TOWER SITE401 S. GRAHAM STREETCHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINADrawing Path: Q:\4335\17\154 Graham and MLK Tower\03_sitemap.mxd plotted by DHomans 11-20-20180 30 60(FEET) SITE MAP ³REFERENCE: 2018 AERIAL PHOTOGRAPHGIS BASE LAYERS WERE OBTAINED FROM MECKLENBURG COUNTY GIS. GROUND LEVEL FLOORPLAN OBTAINED FROM RULE JOY TRAMMELL RUBIO, DATED JULY 27, 2018. THIS MAP IS FORINFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED.THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. Service Layer Credits: meckco !´Ð !´Ð !´Ð Ð"I Ð"I Ð!G Ð!G Ð!G Ð!G Ð!G Ð!GÐ!G Ð!GS Graham StW Martin Luther King Jr Bv TW-1 (10/17/2017)1,2-Dichloroethane: 0.83 µg/L*Tetrachloroethylene (PCE): 68 µg/L* TW-2 (10/17/2017)1,2-Dichloroethane: 1.3 µg/L*Tetrachloroethylene: 200 µg/L*Trichloroethylene: 3.4 µg/L TW-3 (10/17/2017)1,2-Dichloroethane: 0.70 µg/LTetrachloroethylene: 38 µg/L SG-1 (9/29/2018)Tetrachloroethylene: 420 µg/m³ SG-2 (9/29/2018)All < Residential SGSL B-7 (9/29/2018)@12'-16' BGSArsenic: 1.4 mg/kg (J) B-6 (9/29/2018)@2'-6' BGSArsenic: 1.5 mg/kg (J) B-8 (9/29/2018)@5'-7.5' BGSArsenic: 1.9 mg/kg (J) B-4 (9/29/2018)@8'-12' BGSAll < Residential PSRGs B-3 (9/29/2018)@12'-16' BGSAll < Residential PSRGs B-2 (9/29/2018)@2'-6' BGSArsenic: 3.0 mg/kg B-1 (9/29/2018)@8'-12' BGSAll < Residential PSRGs B-5 (9/29/2018)@10'-14' BGSAll < Residential PSRGs Ð"I Soil Gas Sample Locations Ð!G Soil Sample Locations !´Ð Groundwater Sample Locations Proposed Occupied Area Project Parcel SCALE: DATE: PROJECT NUMBER FIGURE NO. 41 " = 30 ' 11-20-18 4335-17-154B GRAHAM TOWER SITE401 S. GRAHAM STREETCHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINADrawing Path: Q:\4335\17\154 Graham and MLK Tower\04_sampleresults.mxd plotted by DHomans 11-20-20180 30 60(FEET) SAMPLE EXCEEDANCES MAP ³REFERENCE: 2017 AERIAL PHOTOGRAPHGIS BASE LAYERS WERE OBTAINED FROM MECKLENBURG COUNTY GIS. THIS MAP IS FORINFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED.THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. Service Layer Credits: meckco Soil samples exceeding the Redsidential Preliminary Soil Remediation Goals (PSRG) forResidential Health and Protection to Groundwater; (February 2018) are shown above. Arsenicvalues observed were within regionally typical natural occurance levels and were likely not theresult of contamination. Soil gas samples exceeding the NCDEQ Residential Vapor Intrusion Exterior Soil GasScreening Levels (SGSL) dated February 2018 are shown above. Groundwater samples exceeding the 2L Standard are shown above.Bold values exceededthe Residential Groundwater Vapor Intrusion Screening Level. *Asterisk marked valuesexceeded the Non-Residential Groundwater Vapor Intrusion Screening Level.* (J) = Estimated concentration between method detection limit and practical quantitation limit. !´Ð !´Ð !´Ð Ð"I Ð"I Ð!G Ð!G Ð!G Ð!G Ð!G Ð!GÐ!G Ð!GS Graham StW Martin Luther King Jr Bv TW-1 TW-2 TW-3 SG-1 SG-2 B-7 B-6 B-8 B-4 B-3 B-2B-1 B-5 Ð"I Soil Gas Sample Locations Ð!G Soil Sample Locations !´Ð Groundwater Sample Locations Proposed Areas of Excavation for Foundations Project Parcel SCALE: DATE: PROJECT NUMBER FIGURE NO. 51 " = 30 ' 11-20-18 4335-17-154B GRAHAM TOWER SITE401 S. GRAHAM STREETCHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINADrawing Path: Q:\4335\17\154 Graham and MLK Tower\05_EXCAVATIONS.mxd plotted by DHomans 11-20-20180 30 60(FEET) FOUNDATION EXCAVATION AREAS ³REFERENCE: 2017 AERIAL PHOTOGRAPHGIS BASE LAYERS WERE OBTAINED FROM MECKLENBURG COUNTY GIS.THISMAP IS FOR INFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONSDISPLAYED ARE APPROXIMATED. THEY ARE NOT BASED ON CIVIL SURVEYINFORMATION, UNLESS STATED OTHERWISE. Service Layer Credits: meckco Attachment II – Tables SVOCs by EPA Method 8270B Chromium VI by EPA Method 7196A Acetone1,4-DichlorobenzeneBenzoic AcidArsenicBariumCadmiumChromiumLeadMercuryChromiumB1 (8-12)09/29/18 8-12 <88.6 <0.12 0.0021 J 0.31 J <2.1 76 <0.21 29 3.5 0.015 J <0.20 B2 (2-6)09/29/18 2-6 <92.8 0.064 J <0.0029 0.34 J 3.0 47 0.31 56 22 0.057 <0.23 B3 (12-16)09/29/18 12-16 <92.2 <0.12 0.0013 J 0.34 J <2.4 76 <0.24 8.9 3.2 0.0068 J <0.22 B4 (8-12)09/29/18 8-12 <93.6 <0.16 0.0018 J 0.32 J <2.2 88 <0.22 17 2.8 0.016 J <0.21 B5 (10-14)09/29/18 10-14 <85.3 <0.10 0.0019 J 0.30 J <2.1 100 <0.21 16 4.0 0.013 <0.20 B6 (2-6)09/29/18 2-6 <89.4 0.071 J <0.0022 0.32 J 1.5 J 71 <0.22 52 21 0.099 <1.0 B7 (12-16)09/29/18 12-16 <83.8 <0.12 0.0029 0.29 J 1.4 J 83 <0.20 9.8 2.9 0.014 J <0.19 B8 (5-7.5)09/29/18 5-7.5 <81.4 0.034 J <0.0022 0.30 J 1.9 J 67 0.13 J 57 89 0.19 <0.19 DUP01 (B1)09/29/18 8-12 NA <0.11 0.0036 0.30 J <2.0 61 <0.20 8.6 2.5 0.014 J <0.19 NS 12,000 2.8 51,000 0.68 3,100 7.5 23,000 NS 2.3 0.31 NS 250 0.12 120 5.80 580 3.0 360,000 270 1.0 3.8 NOTES: Results reported in milligrams per kilogram (mg/kg) ft-BGS : feet below ground surface J : Detected but below the Reporting Limit (lowest calibration standard); therefore, result is an estimated concentration. Redsidential Preliminary Soil Remediation Goals (PSRG) for Residential Health and Protection to Groundwater; February 2018 Chromium values shown for PSRGs are considered to be Chromium III, insoluable salts VALUE = exceeds Residential Health PSRG TABLE 1 Protection of Groundwater PSRG Metals by EPA method 6010D Sample ID Date Collected Sample Depth (ft-BGS) Residential Health PSRG VOCs by EPA Method 8260B S&ME Project # 4335-17-154B, Ph 02 401 S. Graham Street, Charlotte, North Carolina Taken From: Additional Environmental Assessment SUMMARY OF SOIL SAMPLING RESULTS Oil and Grease (with Silica Gel Cleanup) 9071B TABLE 2 SUMMARY OF GROUNDWATER SAMPLING RESULTS Taken From: Limited Phase II Environmental Site Assessment - Proposed Graham and MLK Tower 401 South Graham Street, Charlotte, Mecklenburg County, North Carolina S&ME Project # 4335-17-154B VOCs by EPA Method 8260B SVOCs by EPA Method 8270 Ammonia by SM4500 Ethylene Glycol by EPA 8015C Sample ID Date Collected 1,1-Dichloroethylene1,2-Dichloroethanecis-1,2-DichloroethyleneTrichloroethylene (TCE)AmmoniaTW-1 10/17/17 6.7 2.8 1.1 0.83 4.1 <0.50 <5.0 68 *2.1*all BRL 580 323 J TW-2 10/17/17 5.6 2.6 1.6 1.3 4.7 0.82 <5.0 200 *3.4*all BRL 480 <265 TW-3 10/18/17 8.2 <0.50 1.1 0.70 3.0 0.62 1.1 J 38 *1.9*all BRL <100 <265 6,000 70 350 0.4 70 20 4,000 0.7 3 Varies 1,500 #10,000 19,000,000 36 160 98 NSL 20,000 1,900,000 48 4.4 Varies 670,000 NSL 4,500,000 8.1 39 22 NSL 4,500 450,000 12 1.0 Varies 160,000 NSL Notes: Analytes that are not shown for the method were not detected.Value Indicates value is greater than 2L or IMAC groundwater standard Concentrations are reported in micrograms per liter (µg/L).NSL:No Screening Level for this constituent GROUNDWATER - 2L Standard: North Carolina Groundwater Quality Standards: 15A NCAC 2L.0202 Value:Indicates value is greater than Non-Residential Groundwater Vapor Intrusion Screening Level VAPOR - Non-Residential GW VI Screening Level: Non-Residential Groundwater Vapor Intrusion Screening Level (October 2017) Value*:Indicates value is greater than Residential Groundwater Vapor Intrusion Screening Level VAPOR -Residential GW VI Screening Level: Residential Groundwater Vapor Intrusion Screening Level (October 2017) Value#:2L Standard listed for Ammonia is Interim Maximum Allowable Concentration (IMAC) J: Detected but below the reporting limit; therefore, result is an estimated concentration BRL:Below laboratory reporting limit Ethylene GlycolTetrachloroethylene (PCE)Methyl tert-butyl ether (MTBE)Methyl Ethyl Ketone (MEK)AcetoneVAPOR - Residential GW VI Screening Level Analytical Method → Contaminant of Concern →ChloroformGROUNDWATER - 2L Standard (µg/L) VAPOR - NON - Residential GW VI Screening Level Page 1 of 1 TABLE 3 SUMMARY OF SOIL GAS SAMPLING RESULTS Taken From: Additional Environmental Assessment 401 S. Graham Street, Charlotte, North Carolina S&ME Project # 4335-17-154B, Ph 02 Sample ID Date Collected 2-Butanone (MEK)Carbon DisulfideChloroformChloromethaneCyclohexane1,3-DichlorobenzeneDichlorodifluoromethane (Freon 12)EthanolEthyl AcetateEthylbenzene4-EthyltolueneHeptaneHexaneMethylene Chloride4-Methyl-2-pentanone (MIBK)NaphthalenePropeneTetrachloroethyleneTetrahydrofuranTolueneTrichloroethyleneTrichlorofluoromethane(Freon 11)1,3,5-TrimethylbenzeneVinyl AcetateVinyl chlorideSG-1 9/29/2018 <19 27 11 J 260 1.4 4.5 7.3 16 3.0 <15 <0.72 33 13 34 46 3.0 J 4.8 3.6 J 170 420 1.2 260 1.6 5.0 12 <14 1.4 148 SG-2 9/29/2018 170 33 31 180 2.4 1.7 <0.69 5.5 3.0 18 3.1 39 16 38 34 3.3 J 3.2 7.7 97 270 9.5 340 <1.1 8.5 14 7.1 J <0.51 188 DUP-1 (SG-2)9/29/2018 160 33 33 170 2.4 <0.83 4.8 7.4 2.9 17 3.5 41 16 39 35 5.2 J <0.82 7.4 100 280 12 330 <1.1 7.1 15 8.4 J <0.51 199 220,000 120 35,000 4,900 41 630 42,000 NS 700 NS 490 370 NS 2,800 4,900 4,200 21,000 21 NS 280 14,000 35,000 14 NS 420 1,400 56 700 2,700,000 1,600 440,000 61,000 530 7,900 530,000 NS 8,800 NS 6,100 4,900 NS 35,000 61,000 53,000 260,000 260 NS 3,500 180,000 44,000 180 NS 5,300 18,000 2,800 8,800 Notes: All concentrations in micrograms per cubic meter (µg/m3) VOCs: Volatile Organic Compounds Only constituents detected are shown SGSLs: Exterior Soil Gas Screening Levels (NCDEQ Vapor Intrusion Screening Levels dated February 2018) NS: No current North Carolina standards NA: Not Analyzed Non-Residential SGSLs Total XyleneAnalytical Method → Contaminant of Concern →AcetoneEPA Method TO-15 BenzeneResidential SGSLs Attachment III – Site Conceptual Plans 401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINAC 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT L:\15-085 401 SOUTH GRAHAM - CHARLOTTE\PRESENTATION\2018-03-29COMMISSION NO. 15-085.00 MARCH 29, 2018 401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINAC 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT L:\15-085 401 SOUTH GRAHAM - CHARLOTTE\PRESENTATION\2018-03-29COMMISSION NO. 15-085.00 MARCH 29, 2018 C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT \\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINA C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT \\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINA C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT L:\15-085 401 SOUTH GRAHAM - CHARLOTTE\PRESENTATION\2018-03-29 COMMISSION NO. 15-085.00 MARCH 29, 2018 401 S. GRAHAM STREET MIXED-USE CHARLOTTE, NORTH CAROLINA RJTR COMMISSION NO.: 15-085.00 3/30/2018 S-A S-B S-C S-D 1-A 1-B.1 1-B.2 1-C 1-D 1-E 1-F 1-G 1-H 1-J 1-K 2-A 2-B 2-C GMA RSF USF USF GSF (OUTSIDE F/O/GLASS) RESIDENTIAL COMMON RSF (UNITS ONLY) NUMBER OF UNITS TERRACE GSF 709 674 567 516 771 824 836 776 799 860 831 786 864 847 701 1,178 1,075 1,051 LEVEL 1 22,116 4,972 2,153 3126 2855 2,020 LEVEL 2 21,593 437 167 21,593 48 450 LEVEL 3 22,443 437 167 22,443 55 408 LEVEL 4 22,443 437 167 22,443 56 401 LEVEL 5 22,443 796 481 22,443 56 401 LEVEL 6 22,443 437 167 22,443 56 401 LEVEL 7 22,443 437 167 22,443 56 401 LEVEL 8 24,381 437 167 24,381 64 381 LEVEL 9 22,685 22,583 21,474 19,567 LEVEL 10 22,685 22,583 21,474 19,567 LEVEL 11 22,685 22,583 21,474 19,567 LEVEL 12 22,685 22,583 21,474 19,567 LEVEL 13 22,685 22,583 21,474 19,567 LEVEL 14 22,685 22,583 21,474 19,567 LEVEL 15 22,685 22,583 21,474 19,567 INTERSTITIAL 16*22,685 7,216 LEVEL 17 22,737 15,931 8,088 7,114 9 6,806 1 - - -1 1 1 1 - - - 1 1 1 1 - - - LEVEL 18 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 19 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 20 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 21 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 22 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 23 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 24 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 25 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 26 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 27 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 28 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 29 16,537 16,489 1,796 13,964 17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF 767 SUBTOTAL 583,733 163,053 150,318 136,969 2,153 220,343 33,978 174,682 213 6,806 7,216 160,209 391 410 13 12 12 12 13 13 13 13 12 12 12 13 13 13 1 12 12 12 - 6,013 280 Average RSF per Unit 163,053 156,331 2,433 Total RSF Office and Retail 158,764 Single Tenant Floor (13%)22,333 19,567 Multi Tenant Floor (18.2%)21,936 18,558 RSF/Floor USF/Floor 151 SPACES 213 SPACES 9 SPACES 10 SPACES 383 SPACES 391 SPACES NOTE 1: OFFICE AND RESIDENTIAL GROUND FLOOR CALCULATIONS INCLUDE AREAS DEDICATED FOR EACH USE; SEE SERVICE AREA CALCULATIONS NOTE 3: ** ROOF AND INTERSTITIAL LEVELS, INCLUDING AVAILABLE RESIDENTIAL STORAGE AREAS, ARE PRELIMINARY, PENDING FURTHER DEVELOPMENT AND COORDINATION NOTE 4: DOG SPA LOCATED ON PARKING LEVEL 5 NOTE 5: OFFICE AND RESIDENTIAL PARKING LOBBIES ARE LISTED UNDER THEIR RESPECTIVE CATEGORIES AND ALSO INCLUDED UNDER GSF FOR PARKING NOTE 6: RESIDENTIAL CORE HAS BEEN INCLUDED IN OFFICE BOMA CALCULATIONS ON OFFICE LEVELS AS MAJOR VERTICAL PENETRATIONS AND/OR FLOOR COMMON AREA; ELEVATOR R3 SERVES AS FIREMAN'S ELEVATOR ON ALL FLOORS NOTE 7: PARKING LEVEL STAIRS AND SERVICE AREAS ARE INCLUDED IN PARKING AND OVERALL FLOOR GSF ONLY 16.90%23.00%60.09% TOTAL REQUIRED TOTAL PROVIDED GUEST 84.69% 1/1,000 RSF 1/UNIT 4/1000 OFFICE RESIDENTIAL BRANCH BANK (INCL. IN OFFICE SF ABOVE) 401 SOUTH GRAHAM: AREA CALCULATIONS 49 36 PARKING (INCLUDES LOBBIES***) RESIDENTIAL UNITS ground level & parkingoffice levelsGSF SPACES 128 RATIO TOTAL STRUCTURED AREA (INCLUDING EXTERIOR SPACE) RESID. STORAGE** PARKING PROGRAM TOTAL RESIDENTIAL SF OFFICE/ RETAIL 820 residential levelsBUILDING LEVEL OFFICE SF Building Common Factor at 4% TYPICAL FLOOR RESIDENTIAL EFFICIENCY AREA SUMMARY C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINAGROUND LEVELSOUTH GRAHAM STREETW. MLK JR. BLVD. C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINATYPICAL PARKING LEVEL C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINATYPICAL OFFICE LEVEL C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINARESIDENTIAL/AMENITY LEVEL C 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 03, 2018401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINATYPICAL RESIDENTIAL LEVEL 401 S. GRAHAM STREET MIXED-USECHARLOTTE, NORTH CAROLINAC 2016 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT\\rjtrdata02\projects\15-085 401 South Graham - Charlotte\PRESENTATION\2018-04-02 Color Floor PlanCOMMISSION NO. 15-085.00 APRIL 04, 2018BUILDING SECTION DIAGRAM Attachment IV – Site Construction Drawings LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUED FOR CONSTRUCTION AT−00B 08.14.18COVER SHEET − VOLUME 2401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 401 SOUTH GRAHAM STREET, CHARLOTTE, NC MIXED USE TOWER PROJECT DIRECTORY ARCHITECT/INTERIOR DESIGNER: RULE JOY TRAMMELL + RUBIO, LLC. 300 GALLERIA PARKWAY SUITE 740 ATLANTA, GA 30339 770.661.1492 CONTACT: CHRISTY EMANSKI GENERAL CONTRACTOR: OWNER/DEVELOPER:401 SOUTH GRAHAM MEP/FP ENGINEER: STRUCTURAL ENGINEER: CIVIL ENGINEER & LANDSCAPE DESIGN: GEOTECHNICAL CONSULTANTS: SUSTAINABILITY CONSULTANT: DOMINION REALTY PARTNERS, LLC. 1600 CAMDEN ROAD SUITE 200 CHARLOTTE, NC 28203 704.877.5681 CONTACT: BEAU McINTOSH DOMINION REALTY PARTNERS, LLC. 2626 GLENWOOD AVENUE SUITE 195 RALEIGH, NC 27608 919.582.2044 CONTACT: CHRIS CARLINO MIKE REARDON DOMINION REALTY PARTNERS, LLC. 101 NORTH 5TH STREET SUITE B RICHMOND, VA 23219 804.780.3030 CONTACT: MICHAEL CAMPBELL LANDDESIGN 223 NORTH GRAHAM STREET CHARLOTTE, NC 28202 704.333.0325 CONTACT: NATHAN DOOLITTLE MATT GRIGSBY STANLEY D. LINDSEY AND ASSOCIATES, LTD 2300 WINDY RIDGE PARKWAY SE SUITE 675 SOUTH ATLANTA, GA 30339 770.850.1347 CONTACT: STEVE HAMVAS CATHERINE REICHARD IES 834 INMAN VILLAGE PARKWAY NE SUITE 240 ATLANTA, GA 30307 404.806.2018 CONTACT: MARK KNIPFER ECS SOUTHEAST, LLP 1812 CENTER PARK DRIVE SUITE D CHARLOTTE, NC 28217 704.525.5152 CONTACT: MARC F. PLOTKIN LEPPARD JOHNSON & ASSOCIATES, PC 100 CRESCENT CENTER PARKWAY SUITE 750 TUCKER, GA 30084 770.270.1588 CONTACT: TERRI JOHNSON BEN LEPPARD ENVIRONMENTAL CONSULTANT: S&ME 3201 SPRING FOREST ROAD RALEIGH, NC 27616 919.872.2660 CONTACT: ROGER SMITH BATSON COOK CONSTRUCTION 1900 SOUTH BLVD. SUITE 300 CHARLOTTE, NC 28203 704−790−4040 CONTACT: DAVID HAMILTON CURT RIGNEY CODES & ORDINANCES −2012 N.C. STATE BUILDING CODE −2012 N.C. STATE PLUMBING CODE −2012 N.C. STATE MECHANICAL CODE −2012 N.C. STATE FUEL GAS CODE −2017 N.C. STATE ELECTRICAL CODE (NEC w/ NC AMENDMENTS) −2012 N.C. STATE FIRE CODE −2012 N.C. STATE ENERGY CODE −2012 N.C. ADMINISTRATIVE CODE AND POLICIES −2012 N.C. ACCESSIBILITY CODE(ANSI A117.2009) FAIR HOUSING ACT 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN PROJECT INFO PROJECT NAME: 401 SOUTH GRAHAM LOCATION: CHARLOTTE, NC; MECKLENBURG COUNTY PROJECT DESCRIPTION LOCATED AT THE INTERSECTION OF SOUTH GRAHAM STREET AND WEST MLK JR BLVD, 401 SOUTH GRAHAM IS A VERTICAL MIXED USE PROJECT INCORPORATING APARTMENTS, OFFICE SPACE AND A PARKING GARAGE. THE NET AREA OF THE PROPERTY, WHICH IS LISTED AS TAX PARCEL I.D. NUMBER 07312404 IS APPROXIMATELY 0.6462 ACRES. IT WILL BE LOCATED AT AN EXISTING GRAVEL PARKING LOT DIRECTLY ADJACENT TO AN EXISTING PARKING DECK (ON A DIFFERENT LOT), ACROSS THE STREET FROM THE BB&T BALLPARK/CHARLOTTE KNIGHTS BASEBALL CLUB. THE PROPOSED NEW 29−STORY (INCLUDING ROOF LEVEL) TOWER INCLUDES (FROM TOP TO BOTTOM): 12 LEVELS OF APARTMENTS, 1 TRANSFER/INTERSTITIAL LEVEL, 7 LEVELS OF OFFICE SPACE, AND 8 LEVELS OF PARKING/GROUND FLOOR. PRIMARY USE CLASS OFFICE/RESIDENTIAL/PARKING/MIXED−USE; B/R−2/S−2 OPEN AIR PARKING CONSTRUCTION TYPE: IA − SPRINKLERED LOCATION MAP: North FIRE RESISTANCE RATING REQUIREMENTS PRIMARY STRUCTURAL FRAME: 3 HOUR BEARING WALLS EXTERIOR: 3 HOUR INTERIOR: 3 HOUR NON BEARING WALLS AND PARTITIONS (EXTERIOR): 1 HOUR SEE NOTES ON DRAWINGS NON BEARING WALLS AND PARTITIONS (INTERIOR): N/A FLOOR CONSTRUCTION & SECONDARY MEMBERS: 2 HOUR ROOF CONSTRUCTION AND SECONDARY MEMBERS: 1 1/2 HOUR ALLOWABLE % OPENINGS IN EXTERIOR NONBEARING WALLS AT ADJACENT PROPERTY 45% (SECTION 705.8.2 EXCEPTION : EXTERIOR OPENINGS PROTECTED BY A WATER CURTAIN..) SHAFTS: 2 HOUR OPENING PROTECTIVES 2 HOUR WALL: 1 1/2 HOUR DOOR 1 HOUR WALL: 45 MIN DOOR EXIT ACCESS CORRIDOR: 20 MIN DOOR EXIT ACCESS TRAVEL DISTANCE: BUSINESS 300’, RESIDENTIAL: 250’, STORAGE 400’ COMMON PATH OF TRAVEL: 100 FT MINIMUM CORRIDOR WIDTH: 44 IN MAXIMUM DEAD END CORRIDOR: B& R−2: 50 FT EXIT WIDTH STAIRS: 0.2"/OCCUPANT OTHER EGRESS COMPONENTS: 0.15"/OCCUPANT * ARTISTIC INTERPRETATION ENCLOSURE CONSULTANT: MOISTURE INTRUSION SOLUTIONS (MIS) 704.247.6054 CONTACT: DAVID NELSON ISSUED FOR CONSTRUCTION: 8.14.18 VOLUME 2 Date Issue/Revision LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUED FOR CONSTRUCTION AT−001 08.14.18ISSUE FOR CONSTRUCTION − PERMIT DRAWING LIST401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 ISSUE FOR CONSTRUCTION − PERMIT DRAWING LIST SHEET NUMBERSHEET NAMEISSUE FOR CONSTRUCTION: 08.14.18S7−02 P.T. BEAM DETAILS x S7−03 P.T. BEAM DETAILS x S7−05 P.T. BEAM SCHEDULE x S7−06 P.T. BEAM SCHEDULE x S7−11 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−12 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−13 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−14 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−15 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−16 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−17 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−18 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−19 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−20 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−21 P.T. TRANSFER BEAM SECTIONS AND DETAILS x S7−22 P.T. POOL BEAM SECTIONS AND DETAILS x S7−23 P.T. POOL BEAM SECTIONS AND DETAILS x S7−24 P.T. POOL BEAM SECTIONS AND DETAILS x 05 − MECHANICAL M0−01 MECHANICAL LEGENDS AND NOTES x M1−01 MECHANICAL FLOOR PLAN − LEVEL 01 − GROUND LEVEL x M1−02 MECHANICAL FLOOR PLAN − LEVEL 02 − PARKING LEVEL P2 x M1−03 MECHANICAL FLOOR PLAN − LEVEL 03−07 − TYPICAL PARKING LEVELS P3−P7 x M1−08 MECHANICAL FLOOR PLAN − LEVEL 08 − PARKING LEVEL P8 x M1−09 MECHANICAL FLOOR PLAN − LEVEL 09−14 − TYPICAL OFFICE LEVELS O1−O5 x M1−15 MECHANICAL FLOOR PLAN − LEVEL 15−16 − TYPICAL OFFICE LEVELS O6−O7 x M1−17 MECHANICAL FLOOR PLAN − LEVEL 17 − INTERSTITIAL LEVEL x M1−18 MECHANICAL FLOOR PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1 x M1−19 MECHANICAL FLOOR PLAN − LEVEL 19−29 − TYPICAL RESIDENTIAL UNIT LEVELS R2−R12 x M1−30 MECHANICAL FLOOR PLAN − LEVEL 30 − ROOF PLAN x M1−31 MECHANICAL FLOOR PLAN − LEVEL 31 − PENTHOUSE ROOF x M3−01 MECHANICAL UNIT PLANS x M3−02 MECHANICAL UNIT PLANS x M3−03 MECHANICAL UNIT PLANS x M3−04 MECHANICAL UNIT PLANS x M3−05 MECHANICAL UNIT PLANS x M4−01 MECHANICAL CONDENSER WATER FLOW DIAGRAM x M4−02 MECHANICAL OUTSIDE AIR RISER DIAGRAM x M4−03 MECHANICAL STAIR PRESSURIZATION DIAGRAM x M5−01 MECHANICAL SCHEDULES x M5−02 MECHANICAL SCHEDULES x M6−01 MECHANICAL DETAILS x M6−02 MECHANICAL DETAILS x M6−03 MECHANICAL DETAILS x M6−04 MECHANICAL DETAILS x 06 − ELECTRICAL E0−01 ELECTRICAL LEGENDS AND NOTES x E0−02 LIGHT FIXTURE SCHEDULES x E1−01A ELECTRICAL FLOOR PLAN − UNDERGROUND x E1−01B ELECTRICAL FLOOR PLAN − LEVEL 01 − GROUND LEVEL x E1−02 ELECTRICAL FLOOR PLAN − LEVEL 02 − PARKING LEVEL P2 x E1−03 ELECTRICAL FLOOR PLAN − LEVEL 03 − PARKING LEVEL P3 x E1−04 ELECTRICAL FLOOR PLAN − LEVEL 04 − PARKING LEVEL P4 x E1−05 ELECTRICAL FLOOR PLAN − LEVEL 05 − PARKING LEVEL P5 x E1−06 ELECTRICAL FLOOR PLAN − LEVEL 06 − PARKING LEVEL P6 x E1−07 ELECTRICAL FLOOR PLAN − LEVEL 07 − PARKING LEVEL P7 x E1−08 ELECTRICAL FLOOR PLAN − LEVEL 08 − PARKING LEVEL P8 x E1−09 ELECTRICAL FLOOR PLAN − LEVELS 09−14 − TYPICAL OFFICE LEVELS O1−O5 x E1−15 ELECTRICAL FLOOR PLAN − LEVEL 15−16 − TYPICAL OFFICE LEVELS O6−O7 x E1−17 ELECTRICAL FLOOR PLAN − LEVEL 17 − INTERSTITIAL LEVEL x E1−18 ELECTRICAL FLOOR PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1 x E1−19 ELECTRICAL FLOOR PLAN − LEVEL 19−29 − TYPICAL RESIDENTIAL UNIT LEVEL R2−R12 x E1−30 ELECTRICAL FLOOR PLAN − LEVEL 30 − ROOF PLAN x E1−31 ELECTRICAL FLOOR PLAN − LEVEL 31 − PENTHOUSE ROOF PLAN x E2−01 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 01 − GROUND LEVEL x E2−02 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 02 − PARKING LEVEL P2 x E2−03 ELECTRICAL REFLECTED CEILING PLAN − LEVELS 03−05 − TYPICAL PARKING LEVELS P3−P5 x E2−06 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 06 − PARKING LEVEL P6 x E2−07 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 07 − PARKING LEVEL P7 x E2−08 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 08 − PARKING LEVEL P8 x E2−09 ELECTRICAL REFLECTED CEILING PLAN − LEVELS 09−14 − TYPICAL OFFICE LEVELS O1−O5 x E2−17 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 17 − INTERSTITIAL LEVEL x E2−18 ELECTRICAL REFLECTED CEILING PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1 x E2−19 ELECTRICAL REFLECTED CEILING PLAN − LEVELS 19−29 − TYPICAL RESEDENTIAL LEVEL R2−R12 x E3−01 ELECTRICAL UNIT PLANS x E3−02 ELECTRICAL UNIT PLANS x E3−03 ELECTRICAL UNIT PLANS x E3−04 ELECTRICAL UNIT PLANS x E3−05 ELECTRICAL UNIT PLANS x E3−10 ELECTRICAL ENLARGED PLANS x E4−01 ELECTRICAL RISER DIAGRAM x E4−02 ELECTRICAL RISER DIAGRAM x E4−03 ELECTRICAL RISER DIAGRAM x E4−04 TYPICAL FIRE ALARM RISER x E4−05A LIGHTING STAIRWELL RISER x E4−05B LIGHTING STAIRWELL RISER x E5−01A ELECTRICAL SCHEDULES x E5−01B ELECTRICAL SCHEDULES x E5−03 ELECTRICAL SCHEDULES x E5−06 ELECTRICAL SCHEDULES x E5−08 ELECTRICAL SCHEDULES x E5−09 ELECTRICAL SCHEDULES x E5−10 ELECTRICAL SCHEDULES x E5−11 ELECTRICAL SCHEDULES x E5−12 ELECTRICAL SCHEDULES x E5−14 ELECTRICAL SCHEDULES x E5−15 ELECTRICAL SCHEDULES x E5−16 ELECTRICAL SCHEDULES x E5−17 ELECTRICAL SCHEDULES x E5−18 ELECTRICAL SCHEDULES x E5−19 ELECTRICAL SCHEDULES x E5−22 ELECTRICAL SCHEDULES x E5−25 ELECTRICAL SCHEDULES x E5−28 ELECTRICAL SCHEDULES x E5−30 ELECTRICAL SCHEDULES x E6−01 ELECTRICAL DETAILS x E6−02 ELECTRICAL DETAILS x E6−03 ELECTRICAL DETAILS x 07 − PLUMBING P0−01 PLUMBING LEGENDS AND NOTES x P1−00 PLUMBING UNDERGROUND FLOOR PLAN x P1−01 PLUMBING FLOOR PLAN − LEVEL 01 − GROUND FLOOR PLAN x P1−02 PLUMBING FLOOR PLAN − LEVEL 02 − PARKING LEVEL P2 x P1−03 PLUMBING FLOOR PLAN − LEVEL 03−07 − PARKING LEVEL P3−P7 x P1−08 PLUMBING FLOOR PLAN − LEVEL 08 − PARKING LEVEL P8 x P1−09 PLUMBING FLOOR PLAN − LEVEL 09−16 − TYPICAL OFFICE LEVELS O1−O7 x P1−17 PLUMBING FLOOR PLAN − LEVEL − 17 INTERSTITIAL LEVEL x P1−18 PLUMBING FLOOR PLAN − LEVEL 18 AMENITY/RESIDENTIAL UNIT LEVEL R1 x P1−19 PLUMBING FLOOR PLAN − LEVEL 19−28 − TYPICAL RESIDENTIAL UNIT LEVEL R2−R11 x P1−29 PLUMBING FLOOR PLAN − LEVEL 29 − RESIDENTIAL UNIT LEVEL R12 x P1−30 PLUMBING FLOOR PLAN − LEVEL 30 − ROOF PLAN x P3−01 PLUMBING TYPICAL UNIT PLANS x P3−02 PLUMBING TYPICAL UNIT PLANS x P3−03 PLUMBING TYPICAL UNIT PLANS x P3−04 PLUMBING TYPICAL UNIT PLANS x P3−05 PLUMBING TYPICAL UNIT PLANS x P3−10 PLUMBING ENLARGED PLANS x P4−01 DOMESTIC WATER RISER DIAGRAM − OFFICE x P4−02 DOMESTIC WATER RISER DIAGRAM − RESIDENTIAL TOWER x P4−03 FIRE PROTECTION RISER x P4−04 PLUMBING SANITARY RISERS x P4−05 PLUMBING GAS RISER x P4−06 PLUMBING ISOMETRICS x P5−01 PLUMBING SCHEDULES x P6−01 PLUMBING DETAILS x P6−02 PLUMBING DETAILS x ISSUE FOR CONSTRUCTION − PERMIT DRAWING LIST SHEET NUMBERSHEET NAMEISSUE FOR CONSTRUCTION: 08.14.18A5−21 ENLARGED ELEVATIONS − PARKING DECK x A5−61 ENLARGED ELEVATIONS − PENTHOUSE x A6−01 OVERALL BUILDING SECTIONS − WEST − EAST x A6−02 OVERALL BUILDING SECTIONS − NORTH − SOUTH x A6−11 GROUND LEVEL BUILDING SECTIONS − RESIDENTIAL SERVICE CORRIDOR x A6−12 GROUND LEVEL BUILDING SECTIONS − OFFICE LOBBY x A6−51 ROOF LEVEL BUILDING SECTIONS − PENTHOUSE x A7−01 WALL SECTIONS − NORTH x A7−02 WALL SECTIONS − NORTH x A7−03 WALL SECTIONS − EAST x A7−04 WALL SECTIONS − SOUTH x A7−05 WALL SECTIONS − WEST x A7−11 ENLARGED TRASH CHUTE PLANS/SECTION x A7−33 GROUND FLOOR WALL SECTIONS x A7−34 GROUND FLOOR WALL SECTIONS x A7−35 GROUND FLOOR WALL SECTIONS x A7−36 GROUND FLOOR WALL SECTIONS x A7−41 GROUND FLOOR SECTION DETAILS x A7−42 GROUND FLOOR SECTION DETAILS x A7−43 GROUND FLOOR SECTION DETAILS x A7−44 GROUND FLOOR SECTION DETAILS x A7−51 GROUND FLOOR PLAN DETAILS x A7−61 PARKING WALL SECTIONS x A7−71 PARKING DECK SECTION DETAILS x A7−82 PARKING DECK − CABLE GUARDRAIL DETAILS x A7−100 OFFICE AXONOMETRIC DETAILS x A7−111 OFFICE SECTION DETAILS x A7−121 OFFICE PLAN DETAILS − CURTAIN WALL x A7−131 RESIDENTIAL AXONOMETRIC DETAILS x A7−132 RESIDENTIAL WALL SECTIONS x A7−133 RESIDENTIAL WALL SECTIONS − AMENITY x A7−134 INTERSTITIAL LEVEL − BEAM PENETRATIONS x A7−141 RESIDENTIAL SECTION DETAILS x A7−142 RESIDENTIAL SECTION DETAILS x A7−153 RESIDENTIAL PLAN DETAILS x A7−171 ROOF LEVEL WALL SECTIONS x A7−181 ROOF LEVEL SECTION DETAILS x A7−182 ROOF LEVEL SECTION DETAILS x A7−183 ROOF LEVEL SECTION DETAILS x A8−SA UNIT TYPE S−A x A8−SA.A UNIT TYPE S−A TYPE A x A8−SB UNIT TYPE S−B x A8−SC UNIT TYPE S−C x A8−SD UNIT TYPE S−D x A8−01A UNIT TYPE 1−A x A8−01B UNIT TYPE 1−B x A8−01B.A UNIT TYPE 1−B TYPE A x A8−01C UNIT TYPE 1−C x A8−01D UNIT TYPE 1−D x A8−01E UNIT TYPE 1−E x A8−01F UNIT TYPE 1−F x A8−01G UNIT TYPE 1−G x A8−01H UNIT TYPE 1−H x A8−01H.A UNIT TYPE 1−H TYPE A x A8−01J UNIT TYPE 1−J x A8−01K UNIT TYPE 1−K x A8−02A UNIT TYPE 2−A x A8−02A.1 UNIT TYPE 2−A x A8−02A.A UNIT TYPE 2−A TYPE A x A8−02A.A1 UNIT TYPE 2−A TYPE A x A8−02B UNIT TYPE 2−B x A8−02C UNIT TYPE 2−C x A8−31 KITCHEN & BATH SECTIONS − TYPICAL UNITS x A8−32 KITCHEN & BATH SECTIONS − ACCESSIBLE UNITS x A8−33 KITCHEN & DESK SECTIONS x A8−50 BATH AND SHOWER DETAILS x A8−56 ELEVATOR ELEVATIONS, SECTIONS & DETAILS x A8−57 ELEVATOR ELEVATIONS, SECTIONS & DETAILS x A9−01 DOOR SCHEDULE x A9−02 DOOR & FRAME TYPES x A9−03 DOOR DETAILS − HEAD, JAMB, SILL DETAILS x A9−04 DOOR DETAILS − HOLD OPEN DOOR DETAIL x 04 − ARCHITECTURAL AT−00B COVER SHEET − VOLUME 2 x 04 − STRUCTURAL S0−00 COVER x S0−01 STRUCTURAL NOTES x S0−02 STRUCTURAL NOTES x S1−00 DETENTION VAULT FOUNDATION PLAN x S1−01 LEVEL 1 FOUNDATION PLAN x S1−02 LEVEL 2 − P2 FRAMING PLAN x S1−03 LEVEL 3 − P3 FRAMING PLAN x S1−04 LEVEL 4 − P4 FRAMING PLAN x S1−05 LEVEL 5 − P5 TO 7 − P7 FRAMING PLAN x S1−08 LEVEL 8 − P8 FRAMING PLAN x S1−08.5 LEVEL 8.5 − P8.5 FRAMING PLAN x S1−09 LEVEL 9 − O1 FRAMING PLAN x S1−10 LEVEL 10−O2 TO 12−O4, 14−O5 TO 16−O7 FRAMING PLAN x S1−17 LEVEL 17 INTERSTITIAL FRAMING PLAN x S1−18 LEVEL 18 AMENITY − R1 FRAMING PLAN x S1−18P LEVEL 18 AMENITY − R1 P.T. REINFORCEMENT PLAN x S1−18R LEVEL 18 AMENITY − R1 REINFORCEMENT PLAN x S1−19 LEVEL 19 − R2 FRAMING PLAN x S1−19PR LEVEL 19 − R2 PARTIAL REINFORCEMENT PLANS x S1−20 LEVEL 20 − R3 TO 28 − R11 FRAMING PLAN x S1−20P LEVEL 20 − R3 TO 28 − R11 P.T. REINFORCEMENT PLAN x S1−20R LEVEL 20 − R3 TO 28 − R11 REINFORCEMENT PLAN x S1−29 LEVEL 29 − R12 FRAMING PLAN x S1−30 ROOF LEVEL FRAMING PLAN x S1−30P ROOF LEVEL P.T. REINFORCEMENT PLAN x S1−30R ROOF LEVEL REINFORCEMENT PLAN x S1−31 LEVEL 31 − PENTHOUSE FRAMING PLAN x S2−01 TYPICAL FOUNDATION SECTIONS AND DETAILS x S2−02 TYPICAL FOUNDATION SECTIONS AND DETAILS x S2−03 TYPICAL FOUNDATION SECTIONS AND DETAILS x S2−11 TYPICAL FOUNDATION SECTIONS AND DETAILS x S2−12 FOUNDATION SECTIONS AND DETAILS x S2−21 FOUNDATION SECTIONS AND DETAILS x S2−22 FOUNDATION SECTIONS AND DETAILS x S2−23 FOUNDATION SECTIONS AND DETAILS x S3−01 TYPICAL FRAMING SECTIONS AND DETAILS x S3−02 TYPICAL FRAMING SECTIONS AND DETAILS x S3−11 TYPICAL FRAMING SECTIONS AND DETAILS x S3−12 TYPICAL FRAMING SECTIONS AND DETAILS x S3−21 TYPICAL FRAMING SECTIONS AND DETAILS x S3−22 TYPICAL FRAMING SECTIONS AND DETAILS x S3−23 TYPICAL FRAMING SECTIONS AND DETAILS x S3−31 TYPICAL FRAMING SECTIONS AND DETAILS x S3−41 TYPICAL FRAMING SECTIONS AND DETAILS x S3−51 FRAMING SECTIONS AND DETAILS x S3−52 FRAMING SECTIONS AND DETAILS x S3−53 FRAMING SECTIONS AND DETAILS x S3−61 FRAMING SECTIONS AND DETAILS x S4−01 CONCRETE COLUMN DETAILS x S4−05 COLUMN ELEVATIONS x S4−06 COLUMN ELEVATIONS x S4−07 COLUMN ELEVATIONS x S4−08 COLUMN ELEVATIONS x S4−09 COLUMN ELEVATIONS x S4−10 COLUMN ELEVATIONS x S4−11 COLUMN ELEVATIONS x S4−12 COLUMN ELEVATIONS x S5−01 SHEAR WALL DETAILS x S5−05 SHEAR WALL ELEVATIONS x S5−06 SHEAR WALL ELEVATIONS x S5−07 SHEAR WALL ELEVATIONS x S6−01 CONCRETE BEAM DETAILS x S6−02 CONCRETE BEAM DETAILS x S6−05 CONCRETE BEAM SCHEDULE x S6−11 CONCRETE TRANSFER BEAM SECTIONS AND DETAILS x S6−12 CONCRETE TRANSFER BEAM SECTIONS AND DETAILS x S7−01 P.T. BEAM DETAILS x ISSUE FOR CONSTRUCTION − PERMIT DRAWING LIST SHEET NUMBERSHEET NAMEISSUE FOR CONSTRUCTION: 08.14.1801 − GENERAL AT−00A COVER SHEET − VOLUME 1 x AT−001 ISSUE FOR CONSTRUCTION − PERMIT DRAWING LIST x AT−02 GENERAL INFORMATION x AT−03A APPENDIX B x AT−03B APPENDIX B AND ENERGY MODEL REPORT x AT−04 SPECIAL INSPECTIONS x AT−05 AREA CALCULATIONS x AT−06A PARTITION TYPES x AT−06B PARTITION TYPES x AT−07 TYPICAL MOUNTING HEIGHTS x AT−08A UL DETAILS x AT−08B UL DETAILS x AT−08C UL DETAILS x AT−08D UL DETAILS x AT−08E UL DETAILS x AT−08F UL DETAILS x LS1−01 LIFE SAFETY PLAN − LEVEL 01 − GROUND FLOOR x LS1−02 LIFE SAFETY PLAN − LEVEL 02 − PARKING LEVEL 2 x LS1−03 LIFE SAFETY PLAN − LEVEL 3−6 − TYPICAL PARKING LEVELS P3−P6 x LS1−07 LIFE SAFETY PLAN − LEVEL 07 − PARKING LEVEL P7 x LS1−08 LIFE SAFETY PLAN − LEVEL 08 − PARKING LEVEL 8 x LS1−09 LIFE SAFETY PLAN − LEVEL 09 − OFFICE LEVEL O1 x LS1−10 LIFE SAFETY PLAN − LEVEL 10−12, 14−16 − TYPICAL OFFICE LEVELS O2−O7 x LS1−17 LIFE SAFETY PLAN − LEVEL 17 − INTERSTITIAL LEVEL x LS1−18 LIFE SAFETY PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1 x LS1−19 LIFE SAFETY PLAN − LEVEL 19−29 − TYPICAL RESIDENTIAL LEVEL R2−R12 LS1−30 LIFE SAFETY PLAN − LEVEL 30 − ROOF PLAN 02 − CIVIL C−1.0 COVER SHEET x C−1.1 EXISTING CONDITIONS x C−2.0 DEMOLITION PLAN x L−3.0 OVERALL LAYOUT PLAN x L−3.1 DETAILED LAYOUT PLAN x L−3.2 MATERIALS PLAN x L−3.3 DETAILED AMENITY PLAN x L−3.4 SITE DETAILS x L−3.5 SITE DETAILS x L−3.6 SITE DETAILS x L−4.0 DETAILED GRADING PLAN x L−4.1 DETAILED GRADING PLAN x L−4.2 AMENITY DETAILED GRADING PLAN x C−5.0 STORMWATER PLAN x C−5.1 STORMWATER VAULT PLAN x C−5.2 STORMWATER PROFILE AND DETAILS x C−6.0 UTILITY PLAN x C−6.1 UTILITY PROFILE x C−6.2 UTILITY DETAILS x L−7.00 OVERALL PLANTING PLAN x C−8.00 OVERALL ROADWAY PLAN x C−8.01 ROADWAY PLAN x C−8.02 OVERALL CROSS SECTION PLAN x C−8.03 S. GRAHAM ST. CROSS SECTIONS x C−8.04A S. GRAHAM ST. CROSS SECTIONS x C−8.04B S. GRAHAM ST. CROSS SECTIONS x C−8.05 MLK JR. BLVD. CROSS SECTIONS x C−8.06 MLK JR. BLVD. CROSS SECTIONS x C−8.07A MLK JR. BLVD. CROSS SECTIONS x C−8.07B MLK JR. BLVD. CROSS SECTIONS x C−8.08 S. GRAHAM TRAFFIC CONTROL PH I x C−8.08A S. GRAHAM TRAFFIC CONTROL PH II x C−8.09 MLK JR. BLVD. TRAFFIC CONTROL PH I x C−8.09A MLK JR. BLVD. TRAFFIC CONTROL PH II x C−8.09B MLK JR. BLVD. TRAFFIC CONTROL PH III x C−8.10 TRAFFIC CONTROL NOTES x C−8.11 INTERSECTION SIGHT DISTANCE PLAN x 03 − ARCHITECTURAL A1−01 FLOOR PLAN − LEVEL 01 − GROUND LEVEL x A1−02 FLOOR PLAN − LEVEL 02 − PARKING LEVEL − P2 x A1−03 FLOOR PLAN − LEVEL 03 − PARKING LEVEL − P3 x A1−04 FLOOR PLAN − LEVEL 04 − PARKING LEVEL − P4 x A1−05 FLOOR PLAN − LEVELS 05−06 − PARKING LEVELS − P5−P6 x A1−07 FLOOR PLAN − LEVEL 07 − PARKING LEVEL − P7 x A1−08 FLOOR PLAN − LEVEL 08 − PARKING LEVEL − P8 x A1−09 FLOOR PLAN − LEVEL 09 − OFFICE LEVEL − O1 x A1−10 FLOOR PLAN − LEVEL 10−12, 14−16 − OFFICE LEVELS − O2−O7 x A1−17 FLOOR PLAN − LEVEL 17 − INTERSTITIAL LEVEL x A1−18 FLOOR PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL − R1 x A1−19 FLOOR PLAN − LEVELS 19−28 − RESIDENTIAL UNIT LEVELS − R2−R12 x A1−29 FLOOR PLAN − LEVEL 29 − RESIDENTIAL UNIT LEVEL − R12 x A1−30 FLOOR PLAN − LEVEL 30 − ROOF PLAN x A1−31 FLOOR PLAN − LEVEL 31 − PENTHOUSE ROOF PLAN x A2−01 REFLECTED CEILING PLAN − LEVEL 1 − GROUND LEVEL x A2−05 REFLECTED CEILING PLAN − LEVELS 5−6 − PARKING LEVELS P5−P6 x A2−07 REFLECTED CEILING PLAN − LEVEL 7 − PARKING LEVEL − P7 x A2−08 REFLECTED CEILING PLAN − LEVEL 8 − PARKING LEVEL − P8 x A2−09 REFLECTED CEILING PLAN − LEVEL 9 − OFFICE LEVEL − O1 x A2−10 REFLECTED CEILING PLAN −LEVELS 10−12, 14−16 − OFFICE LEVELS − O2−O7 x A2−17 REFLECTED CEILING PLAN − LEVEL 17 − INTERSTITIAL LEVEL x A2−18 REFLECTED CEILING PLAN − LEVEL 18 − RESIDENTIAL AMENITY LEVEL R1 x A2−19 REFLECTED CEILING PLAN − LEVELS 19−29 − RESIDENTIAL LEVELS R2−R12 x A2−30 REFLECTED CEILING PLAN − LEVEL 30 − RESIDENTIAL UNIT LEVEL R12 x A2−40 ENLARGED RCP − LEVEL 1 − OFFICE LOBBY x A2−41 ENLARGED RCP − LEVEL 9 − TENANT OFFICE LEVEL O1 x A2−42 ENLARGED RCP − LEVELS 10−12, 14−16 − OFFICE TENANT LEVEL O2−O7 x A3−01 ENLARGED PLAN − LEVEL 1 − GROUND LEVEL − OFFICE LOBBY x A3−02 ENLARGED PLAN − LEVEL 1 − GROUND LEVEL − OFFICE CORE x A3−03 ENLARGED PLAN − LEVEL 1.5 − GROUND LEVEL − RESIDENTIAL LOBBY x A3−04 ENLARGED PLANS − LEVEL 2 − PARKING DECK − P2 − MECHANICAL TRANSFER AREA x A3−09 ENLARGED PLAN − LEVEL 9 − OFFICE O1 − LEVEL 9 CORE PLAN x A3−10 ENLARGED PLAN − LEVEL 10−12, 14−16 − OFFICE LEVELS − O2−O7 − CORE PLAN x A3−11 ENLARGED PLANS − OFFICE x A3−12 ENLARGED PLANS/ELEVATIONS − OFFICE RESTROOMS x A3−18 ENLARGED PLANS/ELEVATIONS − LEVEL 18 − RESIDENTIAL − R1 − TERRACES x A3−19 ENLARGED PLANS/ELEVATIONS − LEVEL 18 − RESIDENTIAL − R1 − POOL DECK x A3−20 ENLARGED PLANS/ELEVATIONS − LEVEL 18 − RESIDENTIAL − R1 − AMENITY RESTROOMS x A3−21 ENLARGED PLANS − LEVEL 18 − RESIDENTIAL − R1 x A3−41 STAIR 1 − STAIR PLANS x A3−42 STAIR 1 − STAIR SECTIONS x A3−43 STAIR 2 − STAIR PLANS, SECTIONS + ELEVATIONS x A3−44 STAIR 2 − STAIR PLANS, SECTIONS + ELEVATIONS x A3−45 STAIR 2 − STAIR PLANS, SECTIONS + ELEVATIONS x A3−46 STAIR & RAMP DETAILS x A3−51 ELEVATOR PLANS − OFFICE x A3−52 ELEVATOR PLANS − RESIDENTIAL x A3−53 ELEVATOR PLANS − PARKING DECK x A3−54 ELEVATOR SECTIONS − OFFICE x A3−55 ELEVATOR SECTIONS − RESIDENTIAL x A4−00A OFFICE FINISH SCHEDULE x A4−00B RESIDENTIAL FINISH SCHEDULE x A4−00C UNIT FINISH SCHEDULE x A4−01 FINISH PLAN − GROUND LEVEL x A4−02 FINISH PLAN − ENLARGED OFFICE LOBBY x A4−03 FINISH PLAN − OFFICE CORE x A4−04 FINISH PLAN − TYPICAL RESIDENTIAL CORE x A4−05 FINISH PLAN − DOG WASH AND PARKING ELEVATOR LOBBY x A4−06 FINISH PLAN − AMENITY LEVEL x A4−22 ELEVATIONS − OFFICE LOBBY x A4−23 ELEVATIONS − MAIL ROOMS x A4−25 ELEVATIONS − AMENITY AND RESIDENTIAL x A4−41 OFFICE RECEPTION DESK x A4−42 DETAILS − OFFICE LOBBY x A4−43 DETAILS − LOBBY SECURITY DOOR x A4−44 DETAILS − LOBBY BLIND DOOR x A4−45 DETAILS − FLOOR TRANSITIONS AND MILLWORK x A5−01 BUILDING ELEVATIONS − NORTH AND EAST x A5−02 BUILDING ELEVATIONS − SOUTH AND WEST x A5−11 ENLARGED ELEVATIONS − GROUND LEVEL − NORTH x A5−12 ENLARGED ELEVATIONS − GROUND LEVEL − EAST x A5−13 ENLARGED ELEVATIONS − GROUND LEVEL − SOUTH x A5−14 ENLARGED ELEVATIONS − GROUND FLOOR − WEST x A5−15 ENLARGED ELEVATIONS − GROUND FLOOR − SERVICE x Date Issue/Revision LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:23 PMS0−00 08.14.18COVER401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 401 SOUTH GRAHAM ISSUE FOR CONSTRUCTION 08.14.18 Sheet Number Sheet Name S0-00 COVER S0-01 STRUCTURAL NOTES S0-02 STRUCTURAL NOTES S1-00 DETENTION VAULT FOUNDATION PLAN S1-01 LEVEL 1 FOUNDATION PLAN S1-02 LEVEL 2 - P2 FRAMING PLAN S1-03 LEVEL 3 - P3 FRAMING PLAN S1-04 LEVEL 4 - P4 FRAMING PLAN S1-05 LEVEL 5 - P5 TO 7 - P7 FRAMING PLAN S1-08 LEVEL 8 - P8 FRAMING PLAN S1-08.5 LEVEL 8.5 - P8.5 FRAMING PLAN S1-09 LEVEL 9 - O1 FRAMING PLAN S1-10 LEVEL 10-O2 TO 12-O4, 14-O5 TO 16-O7 FRAMING PLAN S1-17 LEVEL 17 INTERSTITIAL FRAMING PLAN S1-18 LEVEL 18 AMENITY - R1 FRAMING PLAN S1-18P LEVEL 18 AMENITY - R1 P.T. REINFORCEMENT PLAN S1-18R LEVEL 18 AMENITY - R1 REINFORCEMENT PLAN S1-19 LEVEL 19 - R2 FRAMING PLAN S1-19PR LEVEL 19 - R2 PARTIAL REINFORCEMENT PLANS S1-20 LEVEL 20 - R3 TO 28 - R11 FRAMING PLAN S1-20P LEVEL 20 - R3 TO 28 - R11 P.T. REINFORCEMENT PLAN S1-20R LEVEL 20 - R3 TO 28 - R11 REINFORCEMENT PLAN S1-29 LEVEL 29 - R12 FRAMING PLAN S1-30 ROOF LEVEL FRAMING PLAN S1-30P ROOF LEVEL P.T. REINFORCEMENT PLAN S1-30R ROOF LEVEL REINFORCEMENT PLAN S1-31 LEVEL 31 - PENTHOUSE FRAMING PLAN S2-01 TYPICAL FOUNDATION SECTIONS AND DETAILS S2-02 TYPICAL FOUNDATION SECTIONS AND DETAILS S2-03 TYPICAL FOUNDATION SECTIONS AND DETAILS S2-11 TYPICAL FOUNDATION SECTIONS AND DETAILS S2-12 FOUNDATION SECTIONS AND DETAILS S2-21 FOUNDATION SECTIONS AND DETAILS S2-22 FOUNDATION SECTIONS AND DETAILS S2-23 FOUNDATION SECTIONS AND DETAILS S3-01 TYPICAL FRAMING SECTIONS AND DETAILS S3-02 TYPICAL FRAMING SECTIONS AND DETAILS S3-11 TYPICAL FRAMING SECTIONS AND DETAILS S3-12 TYPICAL FRAMING SECTIONS AND DETAILS S3-21 TYPICAL FRAMING SECTIONS AND DETAILS S3-22 TYPICAL FRAMING SECTINS AND DETAILS S3-23 TYPICAL FRAMING SECTIONS AND DETAILS S3-31 TYPICAL FRAMING SECTIONS AND DETAILS S3-41 TYPICAL FRAMING SECTIONS AND DETAILS S3-51 FRAMING SECTIONS AND DETAILS S3-52 FRAMING SECTIONS AND DETAILS S3-53 FRAMING SECTIONS AND DETAILS S3-61 FRAMING SECTIONS AND DETAILS S4-01 CONCRETE COLUMN DETAILS S4-05 COLUMN ELEVATIONS S4-06 COLUMN ELEVATIONS S4-07 COLUMN ELEVATIONS S4-08 COLUMN ELEVATIONS S4-09 COLUMN ELEVATIONS S4-10 COLUMN ELEVATIONS S4-11 COLUMN ELEVATIONS S4-12 COLUMN ELEVATIONS S5-01 SHEAR WALL DETAILS S5-05 SHEAR WALL ELEVATIONS S5-06 SHEAR WALL ELEVATIONS S5-07 SHEAR WALL ELEVATIONS S6-01 CONCRETE BEAM DETAILS S6-02 CONCRETE BEAM DETAILS S6-05 CONCRETE BEAM SCHEDULE S7-01 P.T. BEAM DETAILS S7-02 P.T. BEAM DETAILS S7-03 P.T. BEAM DETAILS S7-05 P.T. BEAM SCHEDULE S7-06 P.T. BEAM SCHEDULE Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 A. GENERAL ----------- 1. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE (WHETHER OR NOT SPECIFICALLY INCORPORATED BY REFERENCE IN THE CONTRACT DOCUMENTS) SHALL BE EFFECTIVE TO CHANGE THE DUTIES AND RESPONSIBILITIES OF OWNER, CONTRACTOR, ENGINEER, SUPPLIER, OR ANY OF THEIR CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE CONTRACT DOCUMENTS. NOR SHALL IT BE EFFECTIVE TO ASSIGN TO THE STRUCTURAL ENGINEER OF RECORD OR ANY OF THE STRUCTURAL ENGINEER OF RECORD'S CONSULTANTS, AGENTS, OR EMPLOYEES ANY DUTY OR AUTHORITY TO SUPERVISE OR DIRECT THE FURNISHING OR PERFORMANCE OF THE WORK OR ANY DUTY OR AUTHORITY TO UNDERTAKE RESPONSIBILITIES CONTRARY TO THE PROVISIONS OF THE CONTRACT DOCUMENTS. 2. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL DOCUMENTS (DRAWINGS AND SPECIFICATIONS), BUT DO NOT INCLUDE SHOP DRAWINGS, VENDOR DRAWINGS, OR MATERIAL PREPARED AND SUBMITTED BY THE CONTRACTOR. 3. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY, ORGANIZATION, OR ASSOCIATION OR TO CODES OF LOCAL OR STATE AUTHORITIES, SHALL MEAN THE LATEST STANDARD, CODE, SPECIFICATION OR TENTATIVE SPECIFICATION ADOPTED AT THE DATE OF TAKING BIDS, UNLESS SPECIFICALLY STATED OTHERWISE. 4. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE CODE OF PRACTICE OR SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS. WHERE A CONFLICT OCCURS WITHIN THE CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENT SHALL GOVERN. 5. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED BUILDING CODE. 6. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL DOCUMENTS. ARCHITECT/STRUCTURAL ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS SEE THE ARCHITECTURAL DRAWINGS. 7. CONTRACTOR SHALL OBTAIN AND COORDINATE EDGE OF SLAB DIMENSIONS, OPENING LOCATIONS AND DIMENSIONS, DEPRESSED SLAB LOCATIONS AND EXTENTS, SLAB SLOPES, CURB LOCATIONS, AND CMU WALL LOCATIONS. ARCHITECT/STRUCTURAL ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. 8. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK. ARCHITECT/STRUCTURAL ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY. 9. CONTRACTOR SHALL VERIFY THAT MISCELLANEOUS FRAMING SHOWN ON THE STRUCTURAL DRAWINGS FOR MECHANICAL EQUIPMENT, OWNER-FURNISHED ITEMS, PARTITIONS, ETC. IS CONSISTENT WITH THE REQUIREMENTS OF SUCH ITEMS. CONTRACTOR SHALL VERIFY EQUIPMENT WEIGHTS, REQUIRED OPENING SIZES AND LOCATIONS IDENTIFIED ON THE STRUCTURAL DRAWINGS ARE IN AGREEMENT WITH FINAL ARCHITECTURAL AND MECHANICAL SHOP DRAWINGS AND SUBMITTALS. 10. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, SAFETY, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA REGULATIONS. 11. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR STABILITY DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, AND INSTALLED BY THE CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTABILITY ANALYSIS, AND ERECTION PROCEDURES, INCLUDING DESIGN AND ERECTION OF FALSEWORK, TEMPORARY BRACING, ETC. 12. REPRODUCTION OF STRUCTURAL DRAWINGS FOR SHOP DRAWINGS IS NOT PERMITTED. 13. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS AND CONNECTIONS SHOWN IN THE CONTRACT DOCUMENTS. REVIEW OF SHOP DRAWINGS SHALL BE FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS REGARDING ARRANGEMENT AND SIZES OF MEMBERS AND THE CONTRACTOR'S INTERPRETATION OF THE DESIGN LOADS AND CONTRACT DOCUMENT DETAILS. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE ARCHITECT/STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK ALL SUBMITTALS AND SHOP DRAWINGS BEFORE SUBMITTING TO THE STRUCTURAL ENGINEER. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE ARCHITECT/STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILITY FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. 14. WHERE A SECTION OR DETAIL IS SHOWN OR DETAILED FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR AND LIKE CONDITIONS. DETAILS LABELED "TYPICAL" OR "TYP." ON THE STRUCTURAL DRAWINGS APPLY TO ALL SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR. THE CONTRACTOR SHALL CONSIDER ALL OF THE CONTRACT DOCUMENTS IN DETERMINING SIMILAR AND LIKE CONDITIONS. 15. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED METAL FRAMING, OR OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE CONNECTION OF THESE SYSTEMS TO THE STRUCTURE. SUCH SYSTEMS SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE PROJECT STATE AND SHALL BE FURNISHED AND INSTALLED BY OTHERS AS REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS. 16. USE ONLY DIMENSIONS INDICATED ON THE CONTRACT DOCUMENTS. DO NOT SCALE DRAWINGS OR MEASURE OBJECTS IN ELECTRONIC FILES. NOTIFY STRUCTURAL ENGINEER AND ARCHITECT OF ANY DISCREPANCIES. 17. THE OWNER SHALL ESTABLISH A PERIODIC MAINTENANCE PROGRAM TO PROTECT THE STRUCTURE FROM DETERIORATION. THE MAINTENANCE PROGRAM IS THE RESPONSIBILITY OF THE OWNER AND SHOULD INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: PAINTING OF EXPOSED STEEL THAT IS NOT GALVANIZED. INSPECTION AND MAINTENANCE OF PROTECTIVE COATINGS, SEALANTS, CAULKED JOINTS, AND CONTROL JOINTS. REPAIR OF SPALLS AND CRACKS IN CONCRETE ELEMENTS. REPAIR AND RESTORATION OF CORRODED ELEMENTS. CLEANOUT OF DRAINS INCLUDING ALL ROOF AND TRENCH DRAINS AND SCUPPERS. CLEANING OF STRUCTURAL ELEMENTS EXPOSED TO HARSH CHEMICALS INCLUDING DE-ICING CHEMICALS. 18. IN THE EVENT THAT CAD FILES OR BIM FILES ARE PROVIDED TO THE CONTRACTOR, NO WARRANTIES, EXPRESSED OR IMPLIED, ARE MADE WITH RESPECT TO THIS FORM OF THE STRUCTURAL DRAWINGS, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IT IS UNDERSTOOD THAT THE USER MAKES USE OF THIS FORM OF THE STRUCTURAL DRAWINGS AT THE USER'S SOLE RISK AND THAT THE CAD OR BIM FILES ARE PROVIDED "AS IS" WITHOUT WARRANTIES OF ANY KIND. THE STRUCTURAL ENGINEER HAS NO OBLIGATION TO OR THROUGH THE USER FOR USE OF THIS FORM OF THE DRAWINGS, INCLUDING ANY OBLIGATION OR LIABILITY FOR THE ACCURACY OF THE INFORMATION FURNISHED VIA THE ELECTRONIC FORM. IN ADDITION TO AND NOTWITHSTANDING THE FOREGOING, IN NO EVENT SHALL THE STRUCTURAL ENGINEER BE LIABLE FOR ANY CONSEQUENTIAL OR SPECIAL DAMAGES OR FOR ANY LOSS OF PROFITS SUSTAINED BY USER IN CONNECTION WITH OR ARISING OUT OF THE USE OF CAD OR BIM FORMS OF THE DRAWINGS. IN ALL CASES, THE HARD COPY OF THE STRUCTURAL DRAWINGS AND SPECIFICATIONS SUPERSEDES ANY CAD OR BIM FILES. B. CODE/DESIGN CRITERIA ------------------------ 1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2012 NORTH CAROLINA BUILDING CODE (BASED ON THE INTERNATIONAL BUILDING CODE, 2009 EDITION). 2. GRAVITY LOADS 2.1 UNIFORM FLOOR LIVE LOADS: OFFICE: OFFICE SPACE (INCLUDES PARTITIONS) 81 PSF CORRIDORS ABOVE FIRST FLOOR 81 PSF LOBBIES AND FIRST FLOOR CORRIDORS 100 PSF RESIDENTIAL: PRIVATE ROOMS AND CORRIDORS SERVING THEM 40 PSF RESIDENTIAL STORAGE (INSIDE UNIT) 40 PSF BALCONIES SAME AS OCCUPANCY SERVED PUBLIC ROOMS AND CORRIDORS SERVING THEM 100 PSF (NON-REDUCIBLE) RESIDENTIAL AMENITY SPACES 100 PSF (NON-REDUCIBLE) GROUND FLOOR PUBLIC SPACES 100 PSF (NON-REDUCIBLE) STAIRS AND EXITS 100 PSF NON-RESIDENTIAL LIGHT STORAGE 125 PSF MECHANICAL ROOMS 125 PSF (NON-REDUCIBLE) OR EQUIPMENT WEIGHT PARKING 40 PSF NON-REDUCIBLE UNLESS NOTED OTHERWISE, ALL LIVE LOADS LESS THAN OR EQUAL TO 100 PSF ARE REDUCIBLE PER THE BUILDING CODE. 2.2 UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE): ROOF 20 PSF SNOW GROUND SNOW LOAD Pg = 10 PSF SNOW EXPOSURE FACTOR Ce = 1.0 SNOW THERMAL FACTOR Ct = 1.0 SNOW IMPORTANCE FACTOR I = 1.0 FLAT ROOF SNOW LOAD Pf = 10 PSF 2.3 CONCENTRATED FLOOR LOADS - DISTRIBUTED OVER AN AREA OF 2.5 FEET SQUARE, UNLESS NOTED OTHERWISE: OFFICE 2000 LB STORE 2000 LB PARKING: FLOOR 3000 LB (ON AREA OF 4.5" X 4.5") GUARD RAIL 6000 LB (BETWEEN 18 AND 27 INCHES ABOVE FLOOR OVER 1 SQUARE FOOT) 2.4 DEAD LOADS (IN ADDITION TO STRUCTURE SELF-WEIGHT): TYPICAL OFFICE LEVEL: FLOORING, SUSPENDED M.E.P. AND CEILING 10 PSF TYPICAL RESIDENTIAL LEVEL: PARTITIONS, FLOORING, SUSPENDED M.E.P. AND CEILING 20 PSF TYPICAL PARKING LEVEL: SUSPENDED M.E.P. 5 PSF LEVEL 18 POOL DECK: FINISH MATERIAL ALLOWANCE INCLUDING TOPPING SLABS, LANDSCAPING AND SUSPENDED M.E.P. AND CEILING 200 PSF OVER RETAIL SPACES: FLOORING, SUSPENDED M.E.P. AND CEILING 20 PSF OVER MECHANICAL ROOMS: FLOORING, SUSPENDED M.E.P. AND CEILING 20 PSF 3. WIND LOADS: IN ACCORDANCE WITH ASCE 7-05 BASIC WIND SPEED (3-SECOND GUST) = 90 MPH OCCUPANCY CATEGORY = II WIND IMPORTANCE FACTOR = 1.00 WIND EXPOSURE = B INTERNAL PRESSURE COEFFICIENT, GCpi = +/- 0.18 SEE SHEET S0-02 FOR DESIGN WIND PRESSURES TO BE USED FOR SELECTION OF EXTERIOR COMPONENTS AND CLADDING MATERIAL NOT SPECIFICALLY DESIGNED BY A REGISTERED DESIGN PROFESSIONAL. 4. EARTHQUAKE LOADS: IN ACCORDANCE WITH ASCE 7-05 OCCUPANCY CATEGORY = II SEISMIC IMPORTANCE FACTOR, I = 1.00 MAPPED SPECTRAL RESPONSE ACCELERATIONS: Ss = 0.317g S1 = 0.106g SITE CLASS = C BASED ON A SITE-SPECIFIC PROBABILISTIC SEISMIC HAZARD ANALYSIS PERFORMED BY ESC SOUTHEAST, LLP ("REPORT OF SEISMIC STUDY - 401 S. GRAHAM TOWER, ECS PROJECT NO. 08-12391-A, DATED DECEMBER 21, 2017), THE FOLLOWING SPECTRAL DESIGN VALUES ARE RECOMMENDED: Sds = 0.202g SD1 = 0.103g SEISMIC DESIGN CATEGORY = B BASIC SEISMIC-FORCE-RESISTING SYSTEM: SHEAR WALL-FRAME INTERACTIVE SYSTEM WITH ORDINARY REINFORCED CONCRETE MOMENT FRAMES AND ORDINARY REINFORCED CONCRETE SHEAR WALLS RESPONSE MODIFICATION COEFFICIENT, R = 4.5 RESPONSE AMPLIFICATION FACTOR, Cd = 4.0 DESIGN BASE SHEAR = 960 KIPS SEISMIC RESPONSE COEFFICIENT, Cs = 0.010 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE 5. MAXIMUM ESTIMATED DEFLECTIONS (IN INCHES) ARE AS FOLLOWS: LIVE LOAD DEAD + LIVE LOAD ------------- ------------------- ROOF MEMBERS: L/360 L/240 FLOOR MEMBERS: L/360 L/240 WHERE, L = SPAN LENGTH (IN INCHES) BETWEEN CENTERLINES OF SUPPORTS. (FOR CANTILEVERS, L IS TWICE THE LENGTH OF THE CANTILEVER.) 6. SPECIAL INSPECTIONS: SPECIAL INSPECTIONS ARE REQUIRED PER IBC CHAPTER 17 AND AS SPECIFIED IN THE SPECIAL INSPECTION STATEMENT PROVIDED BY THE ARCHITECT. 7. NO PROVISIONS HAVE BEEN MADE FOR FUTURE HORIZONTAL OR VERTICAL EXPANSION. C. FOUNDATION -------------- 1. FOUNDATION DESIGN IS BASED ON THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY ECS SOUTHEAST, LLP (ECS PROJECT NUMBER 08:12391), DATED SEPTEMBER 19, 2017 (REVISED APRIL 6, 2018). STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS ENCOUNTERED IN THE FIELD DIFFERENT FROM THOSE ASSUMED FOR DESIGN. 2. STRUCTURAL TESTING/INSPECTION AGENCY SHALL CERTIFY THE BEARING MEDIUM. 3. MISCELLANEOUS INDIVIDUAL SPREAD FOOTINGS AND CONTINUOUS FOOTINGS SUPPORTING LIGHTLY-LOADED STRUCTURES (FOUNDATIONS FOR SITE WALLS, RETAINING WALLS, LOADING DOCK WALLS, RAMP WALLS, STAIRS ON GRADE, CANOPY COLUMNS, ETC.) SHALL BEAR ON SOIL CAPABLE OF SUPPORTING 3,000 PSF. 3. FOOTINGS SUPPORTING BUILDING COLUMNS SHALL BEAR ON ROCK CAPABLE OF SUPPORTING 75 KSF. 3.1 PROVIDE TEST HOLES UNDER FOOTINGS AS NOTED IN THE STRUCTURAL DOCUMENTS. 4. DRIVEN STEEL PILES SHALL BE ONE OF THE FOLLOWING: HP14X89, ASTM A572, GRADE 60 HP14X102, ASTM A572, GRADE 50 5. DRIVEN STEEL PILES SHALL HAVE THE FOLLOWING CAPACITIES: ALLOWABLE VERTICAL COMPRESSIVE LOAD CAPACITY = 250 TONS (500 KIPS) ALLOWABLE VERTICAL TENSION (UPLIFT) LOAD CAPACITY = 50 TONS (100 KIPS) ALLOWABLE LATERAL LOAD CAPACITY = 21.5 TONS (43 KIPS) FOR LOAD APPLIED ALONG WEB OF PILE AND 13.9 TONS (27.8 KIPS) FOR LOAD APPLIED PERPENDICULAR TO WEB OF PILE. 6. THE MINIMUM LENGTH OF A STEEL PILE SHALL BE 10 FEET. 7. FOUNDATION WALLS ARE DESIGNED FOR LATERAL PRESSURES DUE TO THE FOLLOWING EQUIVALENT FLUID DENSITIES: WALLS SUPPORTED AT TOP (AT-REST CONDITION): 64 PCF WALLS FREE TO DISPLACE AT TOP (ACTIVE CONDITION): 44 PCF 8. PROOFROLL BUILDING AREAS WITH TWO COMPLETE COVERAGES OF A LOADED DUMP-TRUCK OR SCRAPER. REPLACE SOFT AREAS WITH COMPACTED STRUCTURAL FILL AS REQUIRED BY THE SPECIFICATIONS. D. REINFORCEMENT ----------------- 1. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE. 2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064 AND HAVE MINIMUM SIDE AND END LAPS OF 8". 3. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE REINFORCING BAR SIZES AND PLACEMENT. WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT ADEQUATE SECTIONS, ELEVATIONS, AND DETAILS IS NOT ACCEPTABLE. 4. PROVIDE DOWELS FROM FOUNDATIONS THE SAME SIZE AND NUMBER AS THE VERTICAL WALL OR COLUMN REINFORCING, UNLESS NOTED OTHERWISE. 5. PLACE REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE: 5.1 CAST-IN-PLACE (NON POST-TENSIONED) CONCRETE REINFORCEMENT COVER PERMANENTLY EXPOSED TO EARTH: CAST AGAINST THE EARTH 3" CLEAR EXPOSED TO EARTH OR WEATHER: FOR BARS LARGER THAN A NO. 5 BAR 2" CLEAR NO. 5 BARS OR SMALLER 1-1/2" CLEAR NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: WALLS 3/4" CLEAR SLABS 3/4" CLEAR COLUMN TIES 1-1/2" CLEAR BEAM/GIRDER STIRRUPS 1-1/2" CLEAR 5.2 CAST-IN-PLACE (POST-TENSIONED) CONCRETE REINFORCEMENT COVER PERMANENTLY EXPOSED TO EARTH: CAST AGAINST THE EARTH 3" CLEAR EXPOSED TO EARTH OR WEATHER: PT SLABS 1" CLEAR PT BEAM/GIRDER STIRRUPS 1-1/2" CLEAR NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: PT SLABS 3/4" CLEAR PT BEAM/GIRDER STIRRUPS 1" CLEAR PT BEAM/GIRDER PRIMARY REINFORCEMENT 1-1/2" CLEAR 5.3 MASONRY CONCRETE REINFORCEMENT COVER MASONRY REINFORCING STEEL SHALL BE PLACED IN THE CENTER OF CMU CELLS, UNLESS NOTED OTHERWISE. IF REINFORCING STEEL IS NOTED TO BE PLACED OTHER THAN THE CENTER OF THE CELL, PLACE BAR TO ACHIEVE 2" CLEAR COVER BETWEEN REINFORCING AND OUTSIDE FACE OF CMU BLOCK. 6. REINFORCEMENT SHALL BE SPLICED ONLY AT LOCATIONS SHOWN OR NOTED IN THE STRUCTURAL DOCUMENTS, EXCEPT REINFORCEMENT MARKED "CONTINUOUS" CAN BE SPLICED AT LOCATIONS DETERMINED BY CONTRACTOR. SPLICES AT OTHER LOCATIONS SHALL BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. REINFORCING STEEL SPLICES SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: CONCRETE REINFORCEMENT: CLASS B TENSION LAP - SEE REINFORCING LAP LENGTH SCHEDULE MASONRY REINFORCEMENT: SEE REINFORCING LAP LENGTH SCHEDULE E. POST-TENSIONED UNBONDED TENDONS ----------------------------------- 1. POST-TENSIONING SYSTEM SHALL BE AN UNBONDED, MONO-STRAND TENDON SYSTEM. POST-TENSIONED TENDONS SHALL BE SEVEN-WIRE STRAND CONFORMING TO ASTM A416 WITH A GUARANTEED MINIMUM ULTIMATE STRENGTH OF 270,000 PSI. 1.1 PROVIDE ENCAPSULATED SYSTEM FOR TENDONS IN AGGRESSIVE ENVIRONMENTS. 2. TENDON PLACEMENT SHALL NOT VARY MORE THAN 1/8" VERTICALLY FROM THE POINTS DIMENSIONED. SLAB TENDONS MAY BE MOVED LATERALLY TO CLEAR OPENINGS, BUT TIE-BACK REINFORCEMENT MAY BE REQUIRED (SEE DETAILS). 3. TENDON SUPPORT BARS AND BOLSTERS SHALL BE SECURED TO THE FORMWORK TO PREVENT DISPLACEMENT OF TENDONS DURING CONCRETE PLACEMENT. 4. STRESSING OF TENDONS MAY COMMENCE AFTER THE CONCRETE HAS OBTAINED A COMPRESSIVE STRENGTH OF 3,000 PSI. POST-TENSIONING OF THE TENDONS SHALL BE COMPLETED WITHIN 96 HOURS OF CONCRETE PLACEMENT. 5. STRESSING SEQUENCE UNLESS NOTED OTHERWISE: 5.1 TWO WAY FLAT SLAB STRESS UNIFORMLY DISTRIBUTED TENDONS FIRST STRESS BANDED TENDONS SECOND 5.2 BEAM AND SLAB STRESS SLAB TENDONS FIRST STRESS BEAM TENDONS SECOND 6. IN THE EVENT OF BROKEN TENDONS OR BLOW-OUTS, SUBMIT FOR APPROVAL TO THE STRUCTURAL ENGINEER DETAILED CALCULATIONS AND PROCEDURES FOR THE REMEDIAL WORK REQUIRED. 7. STRESSING RECORDS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER AFTER THE CONTRACTOR HAS VERIFIED THAT THE REQUIRED NUMBER OF TENDONS INDICATED ON THE SHOP DRAWINGS HAS BEEN STRESSED. IF THERE ARE TENDON ELONGATIONS OUT OF TOLERANCE, A LETTER SIGNED AND SEALED BY THE POST-TENSIONED SUPPLIER'S ENGINEER LICENSED IN THE PROJECT STATE SHALL ACCOMPANY THE STRESSING RECORDS INDICATING THAT LONG-TERM TENDON FORCES REQUIRED BY THE CONTRACT DOCUMENTS WILL BE SATISFIED. CUT TENDONS ONLY AFTER REVIEW OF THE STRESSING RECORDS BY THE STRUCTURAL ENGINEER. (USE CUTTING METHOD OUTLINED IN SPECIFICATIONS.) 8. EXPOSED PORTION OF THE TENDON AND THE GRIPPING PART OF THE ANCHORAGE SHALL BE COATED WITH AN EPOXY-RESIN COMPOUND BEFORE BEING DRY-PACKED WITH A NON-SHRINK GROUT. 9. CORING OF SLABS IS NOT PERMITTED WITHOUT THE WRITTEN CONSENT OF THE STRUCTURAL ENGINEER. OPENINGS AND SLEEVES MUST BE SHOWN ON THE SHOP DRAWINGS. ANY ADDITIONAL OPENINGS NOT SHOWN ON THE APPROVED SHOP DRAWINGS WILL REQUIRE REVIEW BY THE STRUCTURAL ENGINEER PRIOR TO PLACEMENT. 10. UNLESS OTHERWISE SPECIFIED BY THE STRUCTURAL ENGINEER IN THE CONTRACT DOCUMENTS, THE DESIGN AND INSTALLATION OF POST-INSTALLED ANCHORS, SUCH AS MECHANICAL ANCHORS, ADHESIVE ANCHORS, AND POWDER ACTUATED FASTENERS, IN POST-TENSIONED SLABS AND BEAMS IS THE RESPONSIBILITY OF THE CONTRACTOR. DO NOT DAMAGE THE POST-TENSIONING OR MILD REINFORCEMENT DURING INSTALLATION. 11. IN ACCORDANCE WITH ASTM E 119, ALL POST-TENSIONED FLOOR CONSTRUCTION IS CLASSIFIED AS RESTRAINED CONSTRUCTION. F. CAST-IN-PLACE CONCRETE -------------------------- 1. CONCRETE WORK SHALL CONFORM TO ACI 318 AND CRSI STANDARDS. 2. CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES: 2.1 NORMAL WEIGHT STRUCTURAL CONCRETE: MIN. MAX. MAX. EXPOSURE COMPRESSIVE W/C AGGREGATE CLASS STRENGTH, F'C RATIO SIZE -------- ------------- ----- --------- PILE CAPS C1 5,000 PSI 0.40 1" FOOTINGS BEARING ON ROCK C1 5,000 PSI 0.40 1" FOOTINGS BEARING ON SOIL C1 4,000 PSI 0.50 1 1/2" PEDESTALS C1 4,000 PSI 0.50 1" GRADE BEAMS C1 4,000 PSI 0.50 1" INTERIOR FOUNDATION WALLS C1 4,500 PSI 0.45 1" EXTERIOR FOUNDATION WALLS F2,C1 4,500 PSI 0.45 1" INTERIOR SLABS-ON-GRADE C1 4,000 PSI 0.48 1" EXTERIOR SLABS-ON-GRADE F2,C1 4,500 PSI 0.45 1" INTERIOR BEAMS & FRAMED SLABS 5,000 PSI* 0.48 1" EXTERIOR BEAMS & FRAMED SLABS F1,C1 5,000 PSI* 0.40 1" EXTERIOR BALCONIES F1,C1 5,000 PSI 0.40 1" CURBS, PARAPETS, F1,C1 5,000 PSI 0.40 3/4" IMPACT BARRIERS INTERIOR SHEAR WALLS SEE ELEVATIONS 0.48 1" EXTERIOR SHEAR WALLS F1,C1 SEE ELEVATIONS 0.40 1" INTERIOR COLUMNS SEE SCHEDULE 0.48 1" EXTERIOR COLUMNS F1,C1 SEE SCHEDULE 0.40 1" INTERIOR WALLS 5,000 PSI 0.48 1" EXTERIOR WALLS F1,C1 5,000 PSI 0.40 1" *UNLESS OTHERWISE NOTED ALL NORMAL WEIGHT CONCRETE SHALL BE CONSIDERED TO BE IN EXPOSURE CLASS F0, S0, P0, AND C0 ACCORDING TO ACI 318 UNLESS NOTED OTHERWISE ABOVE OR ELSEWHERE ON THE STRUCTURAL DRAWINGS F = FREEZING AND THAWING S = SULFATE P = REQUIRING LOW PERMEABILITY C = CORROSION PROTECTION OF REINFORCEMENT STRENGTH AGE: FOR CONCRETE 7,000 PSI AND LESS USE A 28 DAY STRENGTH FOR CONCRETE GREATER THAN 7,000 PSI EITHER A 28 DAY STRENGTH OR A 56 DAY STRENGTH SHALL BE USED 2.2 LIGHTWEIGHT STRUCTURAL CONCRETE: (110-120 PCF FRESH UNIT WEIGHT/107-116 PCF AIR-DRIED UNIT WEIGHT) MIN. 28-DAY MAX. EXPOSURE COMPRESSIVE AGGREGATE CLASS STRENGTH, F'C SIZE -------- ------------- --------- INTERIOR TOPPING SLABS 4,000 PSI 3/4" EXTERIOR TOPPING SLABS F1,C1 4,000 PSI 3/4" ALL LIGHTWEIGHT CONCRETE SHALL BE CONSIDERED TO BE IN EXPOSURE CLASS F0, S0, P0, AND C0 ACCORDING TO ACI 318 UNLESS NOTED OTHERWISE ABOVE OR ELSEWHERE ON THE STRUCTURAL DRAWINGS 3. CONCRETE MIX REQUIREMENTS 3.1 ALL CONCRETE SHALL BE PROPORTIONED TO COMPLY WITH ACI 318 CHAPTER 4 IN ACCORDANCE WITH THE EXPOSURE CLASS INDICATED. WHERE REQUIREMENTS INDICATED DIFFER FROM REQUIREMENTS OF CHAPTER 4, THE STRICTER REQUIREMENT SHALL APPLY. REFER TO THE SPECIFICATIONS FOR OTHER REQUIREMENTS FOR VARIOUS EXPOSURE CLASSES RELATIVE TO THE CEMENT TYPE, AIR ENTRAINMENT REQUIREMENTS, CHLORIDE ION LIMITS, POZZOLAN LIMITS, AND SHRINKAGE LIMITS. 3.2 CONCRETE SHALL BE CONSIDERED EXTERIOR CONCRETE IF THE CONCRETE IS PERMANENTLY EXPOSED TO THE WEATHER OR MOISTURE OR IF IT IS IN AN UNCONDITIONED SPACE IN ITS COMPLETED CONFIGURATION. 3.3 ALL CONCRETE SHALL SATISFY BOTH THE SPECIFIED MAXIMUM WATER TO CEMENT RATIO AND THE MINIMUM 28 OR 56 DAY COMPRESSIVE STRENGTH, F'C, REQUIREMENTS. 4. PIPES OR DUCTS SHALL NOT EXCEED ONE-QUARTER THE SLAB OR WALL THICKNESS UNLESS SPECIFICALLY DETAILED. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES, ACCESSORIES, ETC. 5. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS OR GROUNDS REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF ALL CONCRETE FINISHES AND SLAB DEPRESSIONS. 6. CONSTRUCTION JOINT LOCATIONS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. NO HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED EXCEPT THOSE SHOWN ON THE STRUCTURAL DRAWINGS. 7. DEFECTIVE AREAS IN CONCRETE INCLUDING, BUT NOT LIMITED TO, HONEY-COMBING, SPALLS, AND CRACKS WITH WIDTHS EXCEEDING 0.01 INCH SHALL BE REPAIRED. EXTENT OF DEFECTIVE AREA TO BE DETERMINED BY THE STRUCTURAL ENGINEER. 8. CONSTRUCTION JOINTS IN FLOORS SHALL BE LOCATED WITHIN THE MIDDLE THIRD OF SPANS OF SLABS, BEAMS, AND GIRDERS. JOINTS IN GIRDERS SHALL BE OFFSET A MINIMUM DISTANCE OF TWO TIMES THE WIDTH OF INTERSECTING BEAMS. 9. POLYSTYRENE BOARDS SHALL CONFORM TO THE FOLLOWING: 9.1 SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 25 PSI WHEN TESTED IN VERTICAL DIRECTION IN ACCORDANCE WITH ASTM D1621-00. 9.2 SHALL MEET PHYSICAL PROPERTY REQUIREMENTS PER ASTM C-578-01, TYPE IX. G. CONCRETE MASONRY -------------------- 1. CONCRETE MASONRY WORK SHALL CONFORM TO ACI 530, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND ACI 530.1, SPECIFICATION FOR MASONRY STRUCTURES. 2. MINIMUM COMPRESSIVE STRENGTH OF CONCRETE MASONRY SHALL BE F'M = 1,500 PSI. 3. MORTAR SHALL BE TYPE S AND SHALL COMPLY WITH THE BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY. 4. CONCRETE MASONRY UNITS SHALL BE GROUTED WITH 2,500 PSI COARSE GROUT AS SHOWN IN THE STRUCTURAL DOCUMENTS. GROUT SHALL CONFORM TO ASTM C476. 5. PROVIDE HORIZONTAL JOINT REINFORCEMENT WITH NO. 9 GAGE LONGITUDINAL WIRES AT 16" VERTICALLY, UNLESS NOTED OTHERWISE. PROVIDE SPECIAL ACCESSORIES FOR CORNERS, INTERSECTIONS, ETC. 6. PROVIDE OPEN BOTTOM BEAM BLOCK UNITS WITH 3" DEEP MINIMUM WEB OPENINGS AT HORIZONTAL REINFORCEMENT LOCATIONS. A MINIMUM CLEAR SPACE OF ONE BAR DIAMETER SHALL BE PROVIDED BETWEEN THE REINFORCING BARS AND THE FACE OF MASONRY UNITS. 7. PROVIDE CONTRACTION (CONTROL) JOINTS IN ALL CONCRETE MASONRY WALLS AT LOCATIONS APPROVED BY THE ARCHITECT AT A MAXIMUM SPACING OF 2.0 TIMES THE WALL HEIGHT OR 25'-0", WHICHEVER IS LESS. 8. PROVIDE DOVETAIL ANCHORS AT 16" C/C, UNLESS NOTED OTHERWISE, WHERE MASONRY WALLS ABUT CONCRETE SURFACES. 9. SUBMIT WRITTEN CONSTRUCTION PROCEDURES PRIOR TO THE START OF MASONRY CONSTRUCTION. 10. MINIMUM VERTICAL WALL REINFORCEMENT SHALL BE #5@32",FOR INTERIOR WALLS AND #5@16", FOR EXTERIOR WALLS, UNLESS NOTED OTHERWISE. H. STRUCTURAL STEEL -------------------- 1. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ANSI/AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND THE AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 2. STRUCTURAL STEEL SHALL BE OF THE FOLLOWING GRADE UNLESS NOTED OTHERWISE ON DRAWINGS: 2.1 W AND WT-SHAPES SHALL CONFORM TO ASTM A992, GRADE 50. 2.2 SQUARE/RECTANGULAR HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM TO EITHER ASTM A500, GRADE C OR ASTM A1085. 2.3 ROUND HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM TO EITHER ASTM A500, GRADE C OR ASTM A1085. 2.4 ROUND PIPE SECTIONS SHALL CONFORM TO ASTM A53, GRADE B. 2.5 OTHER STEEL SHAPES (CHANNELS, ANGLES, PLATES, AND ROUND ROD) MAY CONFORM TO ASTM A36. 3. BOLTS, ANCHOR RODS, AND HEADED STUDS: 3.1 ALL BOLTS SHALL BE A325 OR A490 HIGH STRENGTH BOLTS WITH A 3/4" MINIMUM DIAMETER. THE FOLLOWING CONNECTIONS SHALL BE SLIP CRITICAL: SHEAR CONNECTIONS IN MOMENT CONNECTIONS WITH WELDED JOINTS (MOMENT FRAMES, CANTILEVERS, ETC.) FILED MODIFIED CONNECTIONS HANGERS CONNECTIONS IN BRACED FRAMES OTHER CONNECTIONS AS NOTED IN THE DRAWINGS ALL OTHER CONNECTIONS MAY BE BEARING TYPE. BOLT SHEAR STRENGTH SHALL BE DETERMINED IN ACCORDANCE WITH TABLES 7-1 OR 7-3 AS APPLICABLE IN THE AISC �STEEL CONSTRUCTION MANUAL�, 13TH EDITION. 3.2 ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE. 3.3 HEADED STUDS SHALL BE 3/4" DIAMETER, UNLESS NOTED OTHERWISE, AND SHALL CONFORM TO AWS D1.1. LENGTH OF STUD SHALL BE AS SHOWN ON THE DRAWINGS. 4. CONNECTIONS: 4.1 STEEL CONNECTIONS SHALL BE DETAILED BASED ON THE DESIGN INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. DEVIATION FROM THE CONNECTION DETAILS DEPICTED IN THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED WITHOUT ADVANCE WRITTEN PERMISSION FROM THE STRUCTURAL ENGINEER OF RECORD (SEOR). 4.2 THE SERVICES OF A CONNECTION DESIGN SPECIALTY ENGINEER (CDSE) SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE OF SERVICES. THE CDSE SHALL BE LICENSED IN THE PROJECT STATE. THE CDSE IS RESPONSIBLE FOR REVIEWING THE STEEL SHOP DRAWINGS TO ENSURE THAT ALL CONNECTION DESIGN DETAILS HAVE BEEN CORRECTLY SHOWN ON THE SHOP DRAWINGS; AND, THE CDSE SHALL SUBMIT A SIGNED AND SEALED LETTER, WITH EACH SHOP DRAWING SUBMITTAL, CONFIRMING THE ABOVE REVIEW. 4.3 STANDARD SHEAR CONNECTIONS SHALL BE DETAILED AS DOUBLE-ANGLE, SINGLE- PLATE, SINGLE-ANGLE, OR TEE CONNECTIONS IN ACCORDANCE WITH CONNECTION TABLES IN THE "STEEL CONSTRUCTION MANUAL", 13TH EDITION, PART 10. THE CDSE SHALL SUBMIT SIGNED AND SEALED CALCULATIONS FOR ALL SHEAR CONNECTIONS THAT CANNOT BE DETAILED COMPLETELY FROM THE ABOVE MANUAL FOR REVIEW BY THE SEOR. 4.4 FOR WELDED CONNECTIONS, USE PREQUALIFIED WELDED JOINTS IN ACCORDANCE WITH AISC AND THE STRUCTURAL WELDING CODE OF THE AMERICAN WELDING SOCIETY. "NON-PREQUALIFIED JOINTS" SHALL BE QUALIFIED PRIOR TO FABRICATION. 4.5 THE REQUIRED REACTION USING LRFD LOAD COMBINATIONS SHALL BE AS SHOWN ON THE STRUCTURAL DRAWINGS. IF REACTIONS ARE NOT SHOWN: FOR BEAMS W10 AND SMALLER, PROVIDE CONNECTION WITH A MINIMUM 10 KIP SHEAR CAPACITY; FOR BEAMS W12 AND LARGER, CONTACT THE STRUCTURAL ENGINEER OF RECORD. 4.6 STEEL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS SHALL BE DESIGNED BY THE CDSE WITH THE EXCEPTION OF SIMPLE SHEAR CONNECTIONS AS DESCRIBED IN SECTION 4.3. THE CDSE SHALL SUBMIT SIGNED AND SEALED CALCULATIONS FOR ALL SUCH CONNECTIONS. THE CDSE SHALL USE THE UNIFORM FORCE METHOD WHEN APPLICABLE FOR ALL BRACE AND TRUSS TYPE CONNECTION DESIGNS. 4.7 REVIEW OF THE SHOP DRAWINGS AND / OR CONNECTION CALCULATIONS BY THE SEOR DOES NOT RELIEVE THE CONTRACTOR AND CDSE OF THE FULL RESPONSIBILITY FOR THE DESIGN AND ADEQUACY OF SUCH CONNECTIONS. 5. THE STRUCTURAL STEEL MEMBERS HAVE NOT BEEN DESIGNED TO ACCOMMODATE THE TORSION RESULTING FROM THE ECCENTRIC LOADING OF CURTAINWALL SYSTEMS, LIGHT GAUGE METAL FRAMING, ETC. SUPPLEMENTAL SECONDARY BRACING SHALL BE DESIGNED AND PROVIDED BY THE SUPPLIER TO ELIMINATE TORSION. 6. ALL STEEL EXPOSED TO WEATHER OR MOISTURE SHALL BE GALVANIZED, UNLESS OTHERWISE DIRECTED BY THE ARCHITECT. I. STEEL DECK -------------- 1. DESIGN OF STEEL DECK SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL CONFORM TO THE REQUIREMENTS OF THE STEEL DECK INSTITUTE (SDI) AND THE CONTRACT DOCUMENTS. SUBMIT SHOP DRAWINGS WITH DESIGN LOAD DATA SEALED BY AN ENGINEER LICENSED IN THE PROJECT STATE. REVIEW OF SHOP DRAWINGS SHALL BE FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS REGARDING ARRANGEMENT AND THE CONTRACTOR'S INTERPRETATION OF DESIGN LOADS AND CONTRACT DOCUMENT DETAILS. SUCH REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF THE FULL RESPONSIBILITY FOR THE DESIGN OF THE STEEL DECK. STEEL DECK SHALL BE CAPABLE OF SUPPORTING THE LOADS DESCRIBED IN THE CONTRACT DOCUMENTS CORRESPONDING TO THE NUMBER OF SPANS AND THE SPAN LENGTH. 2. ROOF DECK: 2.1 DECK SHALL BE A MINIMUM OF 20 GAGE, GALVANIZED. J. POST-INSTALLED ANCHORS AND REINFORCING STEEL ------------------------------------------------ 1. POST-INSTALLED ANCHORS AND REINFORCING STEEL SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING POST-INSTALLED ANCHORS OR REINFORCING STEEL IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS OR REINFORCING STEEL. 2. ANCHORS AND REINFORCING STEEL SHALL BE INSTALLED PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII) 3. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW SHALL BE SUBMITTED BY THE CONTRACTOR TO THE STRUCTURAL ENGINEER ALONG WITH CALCULATIONS THAT ARE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. 4. THE CONTRACTOR SHALL ARRANGE ONSITE INSTALLATION TRAINING BY THE MANUFACTURER FOR EACH PRODUCT TO BE INSTALLED. SUBMIT TO THE STRUCTURAL ENGINEER DOCUMENTATION CONFIRMING TRAINING OF ALL PERSONNEL WHO WILL BE INSTALLING PRODUCTS. TRAINING AND DOCUMENTATION SHALL OCCUR PRIOR TO COMMENCEMENT OF PRODUCT INSTALLATION. WHEN REQUIRED PER ACI 318-11 D.9.2.2, INSTALLATION OF ALL ADHESIVE ANCHOR PRODUCTS SHALL BE CONDUCTED BY AN INSTALLER HOLDING CURRENT AAI CERTIFICATION AS ACCREDITED BY ACI/CSRI IN ACCORDANCE WITH ACI 318-11 D.9.2.2. PROOF OF CERTIFICATION SHALL BE MAINTAINED AT THE JOB SITE. 5. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS, CONCRETE STRENGTH AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. IF NO SPACING OR EDGE DISTANCES ARE SPECIFIED ON THE STRUCTURAL DRAWINGS, REFER TO APPLICABLE EVALUATION REPORT FOR CRITICAL SPACING AND EDGE DISTANCES. 6. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR OR REINFORCING LOCATIONS. THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS OR REINFORCING, BY FERROSCAN, GPR, X-RAY, CHIPPING OR OTHER MEANS IN ORDER TO AVOID CONFLICT WITH INSTALLATION. THE CONTRACTOR SHALL NOT DAMAGE ANY REINFORCING STEEL PRIOR TO CONSULTING WITH THE STRUCTURAL ENGINEER. 7. UNLESS NOTED OTHERWISE, THE MINIMUM EMBEDMENT OF EXPANSION AND SCREW ANCHORS SHALL BE 6 TIMES THE ANCHOR DIAMETER, THE MINIMUM EMBEDMENT FOR ADHESIVE ANCHORS SHALL BE 12 TIMES THE ANCHOR DIAMETER, AND THE MINIMUM EMBEDMENT FOR ADHESIVE REINFORCING SHALL BE 12 BAR DIAMETERS. 8. ADHESIVE ANCHOR INSERT SHALL BE: INTERIOR NON-CORROSIVE ENVIRONMENTS: ASTM F1554 Gr. 36 ALL-THREAD ROD EXTERIOR NON-CORROSIVE ENVIRONMENTS: ASTM F1554 Gr. 36 ALL-THREAD ROD HOT-DIPPED GALVANIZED PER ASTM B695, CLASS 65, TYPE I CORROSIVE ENVIRONMENTS: ASTM A193 GR. B8M TYPE 316 ALL-THREAD ROD 9. MECHANICAL AND SCREW ANCHORS IN EXTERIOR NON-CORROSIVE ENVIRONMENTS SHALL BE HOT-DIPPED GALVANIZED PER ASTM B695, CLASS 65, TYPE I 10. ADHESIVE ANCHORS AND REINFORCING STEEL CAPACITY IS DEPENDENT UPON INSTALLATION CONDITIONS. THE FOLLOWING INSTALLATION CONDITIONS HAVE BEEN ASSUMED: HOLES DRILLED WITH HAMMER DRILL WITH CARBIDE TIPPED DRILL BIT DRY HOLE CONCRETE CURED FOR A MINIMUM OF 21 DAYS TEMPERATURE CATEGORY B (110 DEGREES F LONG TERM AND 130 DEGREES F SHORT TERM) IF THESE CONDITIONS DO NOT EXIST, THE CONTRACTOR SHALL SUBMIT ALTERNATE DRILLING METHODS AND MANUFACTURER BOND DATA FOR THE CONDITIONS BEING INSTALLED. 11. POST-INSTALLED ANCHORS AND REINFORCING INSTALLED INTO CONCRETE SHALL BE AS INDICATED BELOW. 11.1 MECHANICAL AND SCREW ANCHORS FOR USE IN CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN CRACKED CONCRETE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. 11.1.1 EXPANSION ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE STRONG-BOLT 2 (ICC ESR-3037) HILTI KWIK BOLT-TZ (ICC ESR-1917) DEWALT POWER-STUD+ SD2 (ICC ESR-2502) 11.1.2 SCREW ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE TITEN-HD (ICC ESR-2713) HILTI KWIK HUS-EZ (ICC ESR-3027) DEWALT SCREW-BOLT+ (ICC ESR-3889 11.1.3 SHALLOW EMBEDMENT ANCHORS (<3/4") SHALL BE ONE OF THE FOLLOWING, U.N.O.: DEWALT MINI-UNDERCUT+ (ICC ESR-3912) 11.2 ADHESIVE ANCHORS FOR USE IN CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN CRACKED CONCRETE IN ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 AND THE ICC-ES EVALUATION SERVICES REPORT SHALL SHOW COMPLIANCE WITH THE BUILDING CODE STATED IN SECTION B OF THESE STRUCTURAL NOTES. 11.2.1 ADHESIVE ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE SET-XP (ICC ESR-2508) HILTI HIT-RE 500 v3 (ICC ESR-3814) DEWALT PURE110+ (ICC ESR-3298) RED HEAD EPCON C6+ (ICC ESR-3577) 11.3 ADHESIVE FOR INSTALLING REINFORCING STEEL IN EXISTING CONCRETE SHALL BE QUALIFIED IN ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 AND THE ICC-ES EVALUATION SERVICES REPORT SHALL SHOW COMPLIANCE WITH THE BUILDING CODE STATED IN SECTION B OF THESE STRUCTURAL NOTES. 11.3.1 ADHESIVE SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE "SET-XP" (ICC-ES ESR-2508) HILTI HIT-RE 500 v3 (ICC ESR-3814) DEWALT PURE110+ (ICC ESR-3298) RED HEAD EPCON C6+ (ICC ESR-3577) STRUCTURAL NOTES LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:26 PMS0−01 08.14.18STRUCTURAL NOTES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 PRESSURE DIAGRAM LEGEND EFFECTIVE AREA PRESSURE (PSF) - SEE NOTES 1 - 9 (SQ. FT) - SEE NOTE 4 ROOF ZONE WALLS OVERHANGS PARAPETS ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 2 ZONE 3 ZONE 4 ZONE 5 < 10 20 50 100 200 > 500 12 2 2 2 3 3 3 3 5 54 a a TYP. MINIMUM COMPONENT AND CLADDING 4 4 5 54aa NOTES: 1. ZONES 1, 2, & 3 APPLY TO THE ROOF AND ZONES 4 & 5 APPLY TO THE WALLS. 2. (+) AND (-) SIGNS INDICATE PRESSURES ACTING TOWARD AND AWAY FROM THE SURFACE, RESPECTIVELY. SEE PARAPET & OVERHANG DIAGRAMS FOR PRESSURE DIRECTION ON THOSE ELEMENTS. 3. "a" DENOTES A DISTANCE OF 4. FOR EFFECTIVE AREAS BETWEEN THOSE PROVIDED, THE PRESSURE IS PERMITTED TO BE INTERPOLATED. OTHERWISE USE THE PRESSURE ASSOCIATED WITH THE LOWER EFFECTIVE AREA. 5. IF A PARAPET GREATER THAN OR EQUAL TO 3'-0" IN HEIGHT IS PROVIDED AROUND THE PERIMETER OF A FLAT ROOF, ZONE 3 MAY BE TREATED AS ZONE 2. 6. THE ABOVE PRESSURES ARE BASED ON A RISK CATEGORY NOMINAL DESIGN WIND SPEED OF - TO CONVERT PRESSURES TO A 10 YEAR DESIGN WIND SPEED OF MULTIPLY ABOVE PRESSURES BY 7. THE COMPONENT AND CLADDING PRESSURES PROVIDED ABOVE ARE INTENDED TO BE USED FOR THE SELECTION OF MISCELLANEOUS PRE-MANUFACTURED AND ENGINEERED ELEMENTS, ASSEMBLIES AND SYSTEMS NOT SPECIFICALLY DESIGNED BY SDL. 8. THE COMPONENT AND CLADDING PRESSURES PROVIDED ABOVE ARE NOT INTENDED TO BE USED FOR THE DESIGN OF ELEMENTS, ASSEMBLIES AND SYSTEMS OUTSIDE SDL'S SCOPE OF SERVICES. 9. THE APPROPRIATE WIND PRESSURES FOR THE DESIGN OF ELEMENTS, ASSEMBLIES AND SYSTEMS SPECIFIED TO BE DESIGNED BY ANOTHER REGISTERED DESIGN PROFESSIONAL SHALL BE DETERMINED BY THAT DESIGNER IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE SPECIFICATIONS AND/OR THE GOVERNING BUILDING CODE.TYP.NOMINAL WIND PRESSURE DIAGRAM (PER ASCE 7-05, METHOD 2) +16, -64 +16, -60 +16, -56 +16, -52 +16, -48 +16, -44 +16, -100 +16, -95 +16, -89 +16, -84 +16, -79 +16, -72 +16, -137 +16, -130 +16, -122 +16, -115 +16, -109 +16, -100 +44, -44 +44, -44 +40, -41 +38, -40 +35, -38 +32, -36 +44, -80 +44, -80 +40, -71 +38, -64 +35, -57 +32, -48 +16, -69 +16, -68 +16, -66 +16, -65 +16, -56 +16, -45 +16, -113 +16, -89 +16, -57 +16, -32 +16, -32 +16, -32 +132, -74 +127, -74 +117, -69 +109, -64 +101, -60 +91, -54 +169, -112 +163, -112 +151, -99 +141, -89 +132, -79 +120, -66 13' - 6". II 76 MPH, 0.44. 89 MPH.PRESSURESPARAPET PRESSURE DIAGRAM(+)PRESSURES(-)ROOF PRESSURES (-) OVERHANG PRESSURE DIAGRAM PRESSURES (+) 12. POST-INSTALLED ANCHORS INSTALLED INTO SOLID GROUTED CONCRETE MASONRY CELLS SHALL BE AS INDICATED BELOW. DO NOT INSTALL ANCHORS INTO HOLLOW HEAD JOINTS OR TEE JOINTS BETWEEN MASONRY BLOCKS. 12.1 MECHANICAL AND SCREW ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC01 AND AC106, RESPECTIVELY. 12.1.1 EXPANSION ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE STRONG-BOLT2 (IAPMO-UES ER-240) HILTI KWIK BOLT-3 (ICC ESR 1385) DEWALT POWER-STUD+ SD1 (ICC ESR-2966) 12.1.2 SCREW ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE TITEN-HD (ICC ESR-1056) HILTI KWIK HUS-EZ (ICC ESR-3056) DEWALT SCREW-BOLT+ (ICC-ES ESR-4042) 12.2 ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58 12.2.1 ADHESIVE ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE "SET-XP" (IAPMO-UES ER-265) HILTI HIT-HY 70 (ICC ESR-2682) DEWALT AC100+ GOLD (ICC ESR-3200) 13. POST-INSTALLED ANCHORS INSTALLED INTO HOLLOW CONCRETE MASONRY SHALL BE AS INDICATED BELOW: 13.1 SCREW ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC106. 13.1.1 SCREW ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: DEWALT TAPPER + (ICC ESR 3196) SIMPSON STRONG-TIE TITEN-HD (ICC ESR-1056) HILTI KWIK-CON II (ICC ESR-NOT AVAILABLE) 13.2 ADHESIVE ANCHORS WITH SCREEN TUBES SHALL BE TESTED AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC58 OR AC60, AS APPROPRIATE. STAINLESS STEEL SCREEN TUBES SHALL BE USED AS RECOMMENDED BY THE ADHESIVE MANUFACTURER. 13.2.1 ADHESIVE ANCHORS SHALL BE ONE OF THE FOLLOWING, U.N.O.: SIMPSON STRONG-TIE "SET-XP" (IAPMO-UES ER-265) HILTI HIT-HY 70 (ICC ESR-2682) DEWALT AC100+ GOLD (ICC ESR-3200) STRUCTURAL NOTES CONCRETE MASONRY UNIT WALL REINFORCING LAP LENGTH SCHEDULE (1) LAP LENGTH BAR SIZE (4) NOTES: 1. LAP SPLICE LENGTHS ARE BASED ON SECTION 2107 OF THE BUILDING CODE. 2. MULTIPLY ABOVE LAP LENGTHS BY 1.25 FOR GRADE 75 REINFORCING STEEL. 3. MULTIPLY ABOVE LAP LENGTHS BY 1.50 FOR EPOXY COATED BARS. 4. REINFORCEMENT LARGER THAN #9 SHALL BE SPLICED USING MECHANICAL CONNECTIONS. 5. USE CASE B UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. TENSION OR COMPRESSION LAP SPLICE LENGTHS, (INCHES) FOR GRADE 60 (2) UNCOATED BARS (3); MASONRY CASE A (5) CASE B (5) #3 15 27 #4 20 36 #5 25 45 #6 30 54 #7 35 63 #8 40 72 #9 46 82 f'c (psi) TENSION LAP SPLICE LENGTHS, (BAR DIAMETERS, db) FOR GRADE 60 (4) UNCOATED BARS; NORMAL-WEIGHT CONCRETE (5) LAP LENGTH PER SPACING AND COVER CASE (3) BAR SIZE LAP CLASS TOP BARS (6) CATEGORY (2) OTHER BARS CATEGORY (2) 1 2 3 A B A B ≥10000 #3-#6 #7-#11 47db 61db 32db 41db 19db 25db 36db 47db 24db 32db 15db 19db 59db 76db 39db 51db 24db 31db 45db 59db 30db 39db 18db 24db LAP NOTES: 1. LAP SPLICE LENGTHS ARE BASED ON ACI 318-05 SECTION 12.2 AND SUBSECTIONS 12.2.2 AND 12.2.3. 2. CATEGORY DEFINITIONS: (SEE FIGURES BELOW FOR ADDITIONAL INFORMATION) CATEGORY 1 - CODE 12.2.2 OTHER CASES - DOES NOT MEET CATEGORY 2 OR 3. CATEGORY 2 - CODE 12.2.2 - CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2db AND CLEAR COVER NOT LESS THAN db. CATEGORY 3 - CODE 12.2.3 - CLEAR COVER NOT LESS THAN 2db AND THE CLEAR SPACING NOT LESS THAN 4db. 3. MINIMUM LAP SPLICE SHALL NOT BE LESS THAN 12 INCHES. 4. MULTIPLY ABOVE LAP LENGTHS BY 1.25 FOR GRADE 75 REINFORCING STEEL. 5. MULTIPLY ABOVE LAP LENGTHS BY 1.3 FOR LIGHTWEIGHT CONCRETE. 6. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE. 7. COMPRESSION LAPS FOR GR. 60 UNCOATED BARS IN NORMAL WEIGHT CONCRETE WITH A MINIMUM STRENGTH OF 3,000 PSI SHALL BE 30db. USE 44db FOR GR. 75 COMPRESSION LAP. CATEGORY 2 CLEAR SPACING AT STAGGERED SPLICES CATEGORY 3 CLEAR SPACING AT OFFSET COLUMN BARS FACE OF CONCRET E OFFSET BARS FROM COLUMN BELOW BARS IN COLUMN ABOVE REINFORCING LAP LENGTH SCHEDULE 1 2 3 A B A B 8000 #3-#6 #7-#11 53db 68db 35db 46db 22db 28db 41db 53db 27db 35db 17db 21db 66db 85db 44db 57db 26db 34db 51db 66db 34db 44db 20db 26db A B A B 7000 #3-#6 #7-#11 56db 73db 38db 49db 24db 30db 43db 56db 29db 38db 18db 23db 70db 91db 47db 61db 28db 37db 54db 70db 36db 47db 22db 28db A B A B 5000 #3-#6 #7-#11 66db 86db 44db 58db 28db 36db 51db 66db 34db 44db 21db 27db 83db 108db 55db 72db 33db 43db 64db 83db 43db 55db 26db 33db A B A B 4000 #3-#6 #7-#11 74db 96db 50db 64db 30db 40db 57db 74db 38db 50db 24db 30db 93db 121db 62db 80db 37db 48db 71db 93db 48db 62db 29db 37db A B A B 3000 #3-#6 #7-#11 86db 111db 57db 74db 34db 46db 66db 86db 44db 57db 26db 34db 107db 139db 72db 93db 43db 56db 82db 107db 55db 72db 33db 43db ≥ 2db≥ dbSPACING CLEAR≥ 4db≥ 2dbFACE OF CONCRET E CLEAR SPACING LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:29 PMS0−02 08.14.18STRUCTURAL NOTES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 2 E.0.7 C.1 D.1 E.8 2.91.8 2.8 2.8 D.4 D.4 C.8C.8 C.9C.9 SW-1A2.3 EQ EQ EQ EQ EQ TYP. EQ EQ 4 S2-23 ____________ 19'-9" T/FND= 701'-0"EQ EQ EQ EQ EQ 25'-0"14'-0" 11'-0" 8'-10"6"15'-8"7'-0" T/FND= 699'-9" PC2 22'-3" 2'-9" D.2 SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S2-0 SERIES SHEETS FOR TYPICAL FOUNDATION DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. "F#" INDICATES FOOTING. SEE 14/S2-11 FOR FOOTING SCHEDULE. 5. "PC#" INDICATES PILE CAP. SEE S2-11 FOR PILE CAP DETAILS. 6. FOOTINGS AND PILE CAPS ARE CENTERED UNDER COLUMNS, UNLESS NOTED OTHERWISE. 7. TOP OF PILE CAP AND FOOTING ELEVATIONS SHALL BE 2'-0" BELOW TOP OF SLAB OR FINISHED GRADE, UNLESS NOTED OTHERWISE ON PLAN: 8. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 9. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 10. S.F. INDICATES STEPPED FOOTING. SEE 7/S2-01. 11. "GB#" INDICATES GRADE BEAM. SEE X/S2-XX FOR GRADE BEAM SCHEDULE. 12. "BP#" INDICATES BASE PLATE, SEE S2-02 FOR BASE PLATE SCHEDULES AND DETAILS. 13. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 14. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 15. AT PARKING AREAS, TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:33 PMS1−00 08.14.18DETENTION VAULT FOUNDATION PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 STORM WATER DETENTION VAULT FOUNDATION PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 SW-1ASW-2ASW-3ASW-4A SW-5A SW-6A CB013 (18 x 23)B-7 PWR = 684'-0" ROCK = 675'-6" B-4 PWR = 710'-0" ROCK = 698'-6" B-1 PWR = 702'-0" ROCK = 687'-6" B-2 PWR = 682'-0" ROCK = 669'-0"B-5 PWR = 680'-0" ROCK = 668'-0" B-8 PWR = 684'-0" ROCK = 674'-0" B-9 PWR = 678'-0" ROCK = 659'-0" B-6 PWR = 675'-0" ROCK = 667'-6" B-3 PWR = 682'-0" ROCK = 665'-6" PC6 PC7 F7 F7 PC8 PC8 PC8 PC7 PC7 PC5PC5PC8 PC7PC5PC5PC5 PC4 PC5 PC3 PC9 PC6 PC6 PC3 PC2 PC6 PC6 PC3 33'-10"11'-6" 13'-6" 6'-4"6"18'-2" 3'-3" 21'-9" 6'-2" 17'-1" T/FND= 703'-11" T/SLAB= 715'-1" T/SLAB= 710'-10" T/SLAB= 711'-0" T/SLAB= 710'-0" T/SLAB= 707'-0" T/SLAB= 711'-0" T/SLAB= 710'-0" 1 S2-21 ____________ 12" TWO-WAY REINF. CONCRETE SLAB 8" CONCRETE SLAB W/ #4@12" E.W. T&B ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT TRUCK DOCK/DRIVE) 8" CONCRETE SLAB W/ #4@12" E.W. T&B ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT TRUCK DOCK/DRIVE) 8" CONCRETE SLAB W/ #4@12" E.W. T&B ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT TRUCK DOCK/DRIVE) 6" CONCRETE SLAB W/ FIBER TYPE "B" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT SERVICE AREAS) 6" CONCRETE SLAB W/ FIBER TYPE "B" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT SERVICE AREAS) 6" CONCRETE SLAB W/ FIBER TYPE "B" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT SERVICE AREAS) 6" CONCRETE SLAB W/ FIBER TYPE "B" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT SERVICE AREAS) 5" CONCRETE SLAB W/ FIBER TYPE "A" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT LOBBY AND PARKING) 5" CONCRETE SLAB W/ FIBER TYPE "A" ON VAPOR RETARDER AND 4" MINIMUM GRANULAR SUB-BASE (TYP. AT LOBBY AND PARKING) RAMP UPRAMP UPRAMP UP RAMP DOWN T/SLAB= 710'-0" RAMP DOWN 5 S2-21 ____________ 3 S2-21 ____________ 4 S2-21 ____________ 6 S2-21 ____________ 7 S2-21 ____________ 4 S2-23 ____________ TYP.4'-0"VARIES2"T/SLAB= 710'-10"4'-3"4 S3-51 7 S3-52 2 S3-61 PC9 #5@12" T&B E.W. - 2.3 PROPERTY LINEPROPERTY LINE T/SLAB= 707'-7" L.0 M.0 N.0 O.0 P.0 Q.0 R.0 S.0 4.0 4.1 5.0 6.0 T/FND= 705'-0"T/FND= 706'-0" T/FND= 706'-0" T/FND= 708'-0" T/FND= 699'-6" T/FND= 704'-0" T/FND= 704'-0" T/FND= 704'-0" T/FND= 713'-0" T/FND= 704'-0" 2"12"DOCK LEVELER T/SLAB= 707'-1" T/SLAB= 706'-1"RAMP DOWNRAMP DOWNRAMP DOWNT/SLAB= 707'-0" T/SLAB= 715'-3" T/SLAB= 715'-1"T/SLAB= 715'-6" CURB - SEE 4/S2-01 T/FND= 704'-0" VARIES S.F.T/FND= 704'-0" PC2 T/SLAB= 707'-0" T/FND= 699'-6" T/FND= 703'-6" T/FND= 703'-6" T/FND= 706'-0" T/FND= 705'-0"T/FND= 705'-0" T/FND= 705'-0" T/FND= 702'-6" T/FND= 703'-6" T/SLAB= 707'-0" T/EXIST. FND= 708'-0" T/EXIST. FND= 706'-0" T/EXIST. FND= 707'-0" T/EXIST. FND= 708'-0" T/EXIST. FND= 708'-0"T/EXIST. FND= 709'-0" EXISTING 4'-0" WIDE x3'-0" DEEP GRADE BEAM EXISTING 3'-0" WIDE x 2'-0" DEEP GRADE BEAM EXISTING DRILLED PIER- TYP. EXISTING PRECAST PARKING DECK T/EXIST. FND= 708'-0" EXISTING RETAINING WALL FOOTING EXISTING RETAINING WALL FOOTING EXISTING RETAINING WALL FOOTING EXIST. PRECAST PARKING DECK EXIST. 4'-0" WIDE CONCRETE WALL TO ELEV. 713'-0" INDICATES APPROXIMATE LOCATION OF PROPERTY LINE, VERIFY EXACT LOCATION WITH ARCH. AND CIVIL DRAWINGS. E.9 2'-0"T/SLAB= 715'-3" T/FND= 710'-0" T/FND= 708'-0"T/FND= 705'-0" T/FND= 705'-0" T/FND= 708'-0" T/FND= 710'-0" PC1 PC1PC1PC1PC1 5.9 ___________8 S3-52 ___________9 S4-01 1 S3-61 ____________ SEE 1/S3-23 T/SLAB= 706'-3" T/SLAB= 707'-0" T/FND= 699'-9" T/SLAB= 715'-3" T/SLAB= 715'-3"2"2"4'-3"2"F4 F4 10" 3'-5" HSS8x4x1/4 HSS8x4x1/4T/FND= 699'-6" T/FND= 701'-6"4'-0"S.F. S.F. 2'-6"TYP.2'-6"T/FND= 705'-0" T/FND= 704'-5" T/FND= 707'-0" T/FND= 709'-0" T/FND= 713'-0" T/FND= 712'-0"T/FND= 710'-0"T/FND= 708'-0" T/FND= 706'-0" T/FND= 705'-0" T/FND= 705'-0" T/FND= 705'-0" T/FND= 705'-0" ___________1 S2-12 ___________2 S2-12 HSS8x4x1/4 F4 F4 PC2 T/FND= 704'-5" T/FND= 704'-5" T/FND= 705'-5" T/FND= 705'-5" 11 S2-03 ____________ 9 S2-03 ____________ 11 S2-03 ____________ 9 S2-03 ____________ 9 S2-03 ____________11 S2-03 ____________ 11 S2-03 ____________ HSS8x8x5/8 HSS8x8x5/8 HSS12x8x1/2 HSS12x8x1/2 T/FND= 705'-5" T/FND= 706'-0" T/FND= 706'-0" D.2 1 S2-22 ____________ T/SLAB= 710'-0" CURB - SEE 4/S2-01 T/SLAB= 710'-0" T/FND= 706'-0" T/FND= 707'-0" 4'-0"S.F.T/FND= 704'-5" T/FND= 703'-11" T/FND= 705'-0" T/FND= 707'-0" T/FND= 709'-0" 4'-0" 4'-0" 4'-0"S.F.S.F.S.F.VARIES 2'-5"T/FND= 714'-3" T/FND= 714'-3" T/FND= 705'-6" T/FND= 704'-5" SEE 2/S2-21 T/FND= 704'-0" S.F. S.F. 3 S2-21 ____________ 2 S2-22 ____________2 S2-22 ____________2 S2-22 ____________T/FND= 706'-0" T/FND= 708'-0" 4 S2-22 ____________ 4 S2-22 ____________ T/FND= 708'-0" T/FND= 708'-0" 3 S2-22 ____________ 3 S2-22 ____________ 3 S2-22 ____________ 5 S2-22 ____________5 S2-22 ____________6 S2-22 ____________7 S2-22 ____________8 S2-22 ____________ 1 S2-23 ____________ 1 S2-23 ____________ 1 S2-23 ____________ 8 S2-22 ____________ 2 S2-23 ____________ T/FND= 703'-6" 2 S2-23 ____________ T/FND= 699'-6" 3 S2-23 ____________ T/FND= 699'-6" 3 S2-23 ____________ T/FND= 699'-6"7'-4"7'-4"4'-0" 9'-6" 9'-6" 2'-6" T/FND= 703'-11" 5 S2-23 ____________ T/FND= 703'-11" T/FND= 711'-2" VARIES 6 S2-23 ____________ SEE NOTE 14 6 S2-23 ____________ VARIES 6 S2-23 ____________ 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8" 1'-2" 23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"26'-5" 7'-0" 12'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4" T/FND= 711'-0"T/FND= 709'-11" T/FND= 707'-11" 4'-0" 4'-0" 4'-0"S.F.S.F.S.F.S.F.T/FND= 703'-11" SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S2-0 SERIES SHEETS FOR TYPICAL FOUNDATION DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. "F#" INDICATES FOOTING. SEE 14/S2-11 FOR FOOTING SCHEDULE. 5. "PC#" INDICATES PILE CAP. SEE S2-11 FOR PILE CAP DETAILS. 6. FOOTINGS AND PILE CAPS ARE CENTERED UNDER COLUMNS, UNLESS NOTED OTHERWISE. 7. TOP OF PILE CAP AND FOOTING ELEVATIONS SHALL BE 2'-0" BELOW TOP OF SLAB OR FINISHED GRADE, UNLESS NOTED OTHERWISE ON PLAN: 8. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 9. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 10. S.F. INDICATES STEPPED FOOTING. SEE 7/S2-01. 11. "GB#" INDICATES GRADE BEAM. SEE X/S2-XX FOR GRADE BEAM SCHEDULE. 12. "BP#" INDICATES BASE PLATE, SEE S2-02 FOR BASE PLATE SCHEDULES AND DETAILS. 13. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 14. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 15. AT PARKING AREAS, TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:39 PMS1−01 08.14.18LEVEL 1 FOUNDATION PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 1 FOUNDATION PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 S29 S17 S20 S21S22S22S23S24S18S10S11S9S25S25S9 S12 S10 S26 S17S30 S26 S3S3S3S19S19S19S32S31S33 S33 S11 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 PB139 (24 x 23)PB142 (24 x 23)PB140 (24 x 23)PB156 (44 x 23)PB157 (44 x 23)PB158 (44 x 23)PB147 (18 x 23) PB101 (18 x 23)PB141 (24 x 23)PB138 (18 x 23) PB138 (18 x 23)PB138 (18 x 23)PB138 (18 x 23)PB143 (24 x 23)PB159 (44 x 23)PB160 (44 x 23)PB151 (40 x 23)PB152 (40 x 23)PB153 (40 x 23)CB006 (18 x 23)CB012 (24 x 23)PB145 (24 x 23)CB013 (18 x 23)CB013 (18 x 23)PB144 (24 x 23)CB006 (18 x 23) PB146 (24 x 23)PB145 (24 x 23)SW-1ASW-2APB112 (34 x 23) CB005 (30 x 23)PB104 (36 x 23)PB105 (40 x 23)PB101 (18 x 23)PB128 (48 x 23)PB106 (48 x 23)PB127 (48 x 23)PB101 (18 x 23)PB102 (24 x 23) PB102 (24 x 23)SW-3ASW-4A SW-5A SW-6A 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 W10x12 W10x12 W10x12 W10x12 W10x12 18 x 18 BARRIER CABLE ANCHOR POST 1 1/2"-TYPE "B" ROOF DECK DECK BEARING = 729'-5 1/2"W10x12W10x12W10x12W10x12W10x12RAMP UP FROM P1 RAMP UP TO P3 RAMP UPRAMP UPRAMP UP RAMP UP RAMP UP PB146 (24 x 23) PB108 (34 x 23)PB149 (18 x 23)PB148 (18 x 23)CB001 (12 x 23)SEE ARCH. FOR CONCRETE CURB LOCATIONS, TYP.4 S3-51 HSS12x8x3/87 S3-52 2 S3-61 2.3 E.9 2'-0"PB154 (60 x 23)PB155 (60 x 23)PB125 (32 x 23)PB126 (48 x 23)PB102 (24 x 23) PB102 (24 x 23)PB101 (18 x 23)PB101 (18 x 23)PB150 (40 x 23)PB106 (48 x 23)5.9 PB107 (18 x 23) PB135 (18 x 23) PB133 (30 x 23) - SEE NOTE 8PB161 (60 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB109 (30 x 23)PB110 (30 x 23)PB111 (30 x 23)CB001 (12 x 23)PB130 (18 x 23) CB004 (8 x 23)CB006 (18 x 23)PB134 (18 x 23)CB006 (18 x 23)CB006 (18 x 23)PB135 (18 x 23)CB006 (18 x 23)CB015 (18 x 23)CB001 (12 x 23)(18/34 x 23)(34/18 x 23) 1 S7-03 ____________ 4 S7-02 ____________4 S7-02 ____________CB006 (18 x 23)PB138 (18 x 23) ___________9 S6-02 1 S3-53 ____________ 4 S7-02 ____________CB001 (12 x 23)4 S7-02 ____________CB004 (8 x 23)CB004 (8 x 23) CB014 (18 x 23) PB116 (40 x 23)CB001 (12 x 23)CB004 (8 x 23)CB016 (12 x 23)CB017 (12 x 23) 11 S3-22 ____________ 11 S3-22 ____________ 12 S3-22 ____________ 11 S3-22 ____________ 9 S3-31 ____________ 12 S3-22 ____________ ___________9 S4-01 HSS8x4x1/4 4 S7-02 ____________ HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 7 S3-02 ____________ D.2 T/SLAB= 728'-1" T/SLAB= 729'-7" T/SLAB= 732'-0" T/SLAB= 732'-6" T/SLAB= 735'-4" T/SLAB= 736'-1" SEE 2/S3-41 SEE 2/S3-41 BARRIER CABLE ANCHOR POST 18 x 18 BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. 1 1/2"-TYPE "B" ROOF DECK DECK BEARING = 730'-5 1/2"W10x12W10x1215 S3-22 ____________ 15 S3-22 ____________1'-3"1'-3" 15 S3-22 ____________1'-3"BARRIER CABLES - SEE ARCH. ___________6 S3-41 CB003 (12 x 23)CB002 (12 x 23)CB003 (12 x 23)CB004 (8 x 23)BARRIER CABLE ANCHOR COL. SEE 4/S3-41 11 S3-22 ____________ SIM.33'-10"11'-6"13'-6"6'-4"6"18'-2"3'-3"21'-9"6'-2"17'-1"26'-5" 7'-0" 12'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4" 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:44 PMS1−02 08.14.18LEVEL 2 − P2 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 2 - P2 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 S22S22S22S23S24S27S28S17S20S3S19S3S18S3 S10S11S9S25S25S25S9 S9 S12 S10 S26 S17 S11 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 SW-1ASW-2APB113 (40 x 23)PB114 (40 x 23)PB122 (44 x 23)PB123 (44 x 23)PB101 (18 x 23) PB103 (36 x 23) CB007 (18 x 23)PB124 (44 x 23)PB101 (18 x 23) PB101 (18 x 23) PB131 (48 x 23)PB121 (44 x 23)PB120 (44 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)(48 x 23)PB116 (40 x 23) PB136 (18 x 23)CB001 (12 x 23)PB137 (18 x 23)CB010 (12 x 23) PB107 (18 x 23)PB108 (34 x 23) PB115 (40 x 23)PB129 (60 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB111 (30 x 23)PB110 (30 x 23)PB109 (30 x 23) PB130 (18 x 23) PB134 (18 x 23)CB006 (18 x 23)CB006 (18 x 23)PB135 (18 x 23)CB006 (18 x 23)CB003 (12 x 23)CB002 (12 x 23)CB003 (12 x 23) CB001 (12 x 23)CB004 (8 x 23)CB001 (12 x 23)PB101 (18 x 23)PB101 (18 x 23)PB105 (40 x 23)PB112 (34 x 23) CB005 (30 x 23)PB128 (48 x 23)PB106 (48 x 23) PB102 (24 x 23) PB102 (24 x 23) PB102 (24 x 23)PB127 (48 x 23)PB125 (32 x 23)PB102 (24 x 23) PB119 (40 x 23)PB118 (40 x 23)PB104 (36 x 23)SW-3ASW-4A SW-5A SW-6A 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 CB004 (8 x 23)RAMP UP FROM P2 RAMP UP TO P4 RAMP UPRAMP UPRAMP UP BARRIER CABLE ANCHOR POST 18 x 18 18 x 18 BARRIER CABLE ANCHOR POST 18 x 18BARRIER CABLE ANCHOR POST 18 x 18BARRIER CABLE ANCHOR POST 18 x 18BARRIER CABLE ANCHOR POST 18 x 30 BARRIER CABLE ANCHOR POST 18 x 36 BARRIER CABLE ANCHOR POST 18 x 30 BARRIER CABLE ANCHOR POST PB133 (30 x 23) RAMP UP SEE ARCH. FOR CONCRETE CURB LOCATIONS, TYP.CB001 (12 x 23)CB011 (8 x 23)CB001 (12 x 23)4 S3-51 7 S3-52 2.3 E.9 PB132 (30 x 23)PB101 (18 x 23)PB101 (18 x 23)CB (12 x 70)CB (12 x 23) TRANSFORMER TROLLEY BEAM B/STEEL = 743'-3"B/STEEL = 743'-3"B/STEEL = 743'-3"W14x34W14x34W14x34S20X86 1 S3-52 ____________ 6 S3-52 ____________ 4 S3-52 ____________ 5.9 3 S3-52 ____________5 S3-52 ____________CB (12 x 23)T/SLAB EL. = 747'-1" 6 1/2" ONE-WAY REINF. CONCRETE SLABCB009 (12 x 23)4 S7-02 ____________4 S7-02 ____________ 4 S7-02 ____________ (18/34 x 23)(34/18 x 23) 1 S7-03 ____________ PB117 (40 x 23)PB126 (48 x 23)- SEE NOTE 8 PB134 (18 x 23)CB006 (18 x 23)CB004 (8 x 23)HSS8x4x1/4PB135 (18 x 23)CB006 (18 x 23)12 S3-22 ____________ 12 S3-22 ____________ ___________9 S4-01 HSS8x4x1/4 4 S7-02 ____________ HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 7 S3-02 ____________ D.2 T/SLAB= 740'-7" T/SLAB= 743'-0" T/SLAB= 746'-4" T/SLAB= 747'-1" T/SLAB= 743'-6" BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. 15A S3-22 ____________1'-3"15A S3-22 ____________ 1'-3" 15 S3-22 ____________1'-3"15 S3-22 ____________ 1'-3" 15A S3-22 ____________ BARRIER CABLES - SEE ARCH. ___________6 S3-41 2'-0"2'-0"33'-10"11'-6"13'-6"6'-4"6"18'-2"3'-3"21'-9"6'-2"17'-1"26'-5" 7'-0" 12'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4" 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:48 PMS1−03 08.14.18LEVEL 3 − P3 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 3 - P3 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 S17S20 S21S22S22S23S24S3S19S3S18S3S10S11S9S25S25S25S9 S9 S12 S10 S26 S17 S11 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 PB120 (44 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB114 (40 x 23)PB115 (40 x 23)PB116 (40 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB121 (44 x 23)PB101 (18 x 23) PB101 (18 x 23)PB123 (44 x 23)PB124 (44 x 23)PB108 (34 x 23) PB103 (36 x 23) CB007 (18 x 23)PB137 (18 x 23)PB136 (18 x 23) PB101 (18 x 23)CB001 (12 x 23)PB107 (18 x 23)CB009 (12 x 23)CB010 (12 x 23) CB011 (8 x 23) PB130 (18 x 23) PB134 (18 x 23)PB101 (18 x 23)PB110 (30 x 23)PB111 (30 x 23) PB135 (18 x 23)CB006 (18 x 23)CB006 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB004 (36 x 23)CB005 (30 x 23)PB128 (48 x 23)PB125 (32 x 23)PB118 (40 x 23)PB119 (40 x 23) PB102 (24 x 23) PB102 (24 x 23) PB117 (40 x 23)PB101 (18 x 23)PB127 (48 x 23)PB102 (24 x 23) PB102 (24 x 23)PB106 (48 x 23)CB004 (8 x 23)PB129 (60 x 23)SW-1APB113 (40 x 23) PB109 (30 x 23)PB005 (40 x 23)PB106 (48 x 23)PB122 (44 x 23)PB131 (48 x 23)SW-2ASW-3ASW-4A SW-5A SW-6A 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 HSS8x4x1/4RAMP UP FROM P3 RAMP UP TO P5 RAMP UPRAMP UP18 x 18 18 x 18 18 x 36 18 x 30 18 x 18 18 x 18 18 x 18 18 x 30 BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST RAMP UP RAMP UP PB132 (30 x 23) PB134 (18 x 23)CB001 (12 x 23)E.9 5.9CB001 (12 x 23)4 S7-02 ____________4 S7-02 ____________ 4 S7-02 ____________PB101 (18 x 23)PB101 (18 x 23)PB126 (48 x 23)PB112 (34 x 23)(18/34 x 23)(34/18 x 23)CB001 (12 x 23)PB133 (30 x 23)CB006 (18 x 23)CB004 (8 x 23)CB006 (18 x 23)- SEE NOTE 8 CB006 (18 x 23)1 S7-03 ____________SEE ARCH. FOR CONCRETE CURB LOCATIONS, TYP. 12 S3-22 ____________ 12 S3-22 ____________ ___________9 S4-01 HSS8x4x1/4 4 S7-02 ____________ HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 7 S3-02 ____________ D.2 T/SLAB= 751'-7" T/SLAB= 754'-0" T/SLAB= 757'-4" T/SLAB= 758'-1" T/SLAB= 754'-6" BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. 15A S3-22 ____________ 15A S3-22 ____________ 15 S3-22 ____________ 15 S3-22 ____________ 1'-3"1'-3"1'-3"1'-3"15A S3-22 ____________ 15A S3-22 ____________ BARRIER CABLES - SEE ARCH. ___________6 S3-41 CB003 (12 x 23)CB002 (12 x 23)CB003 (12 x 23)CB004 (8 x 23)23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"2'-0"31'-10"11'-6"13'-6"6'-4"6"18'-2"3'-3"21'-9"6'-2"17'-1"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:52 PMS1−04 08.14.18LEVEL 4 − P4 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 4 - P4 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 S17S20 S21S22S22S23S24S3S19S3S18S3S10S11S9S25S25S25S9 S9 S12 S10 S26 S17 S11 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 SW-1APB120 (44 x 23)PB113 (40 x 23)PB114 (40 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB121 (44 x 23)PB122 (44 x 23)PB131 (48 x 23) PB101 (18 x 23) PB101 (18 x 23)PB123 (44 x 23)PB124 (44 x 23)PB101 (18 x 23) PB103 (36 x 23) PB108 (34 x 23)PB107 (18 x 23) CB007 (18 x 23) PB136 (18 x 23)PB137 (18 x 23)CB001 (12 x 23)PB129 (60 x 23)PB109 (30 x 23) PB130 (18 x 23)PB101 (18 x 23)PB134 (18 x 23) PB110 (30 x 23)PB111 (30 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)CB006 (18 x 23)PB135 (18 x 23)CB006 (18 x 23)PB112 (34 x 23)PB126 (48 x 23)PB127 (48 x 23)PB128 (48 x 23)CB005 (30 x 23) PB106 (48 x 23)PB104 (36 x 23)PB101 (18 x 23)PB101 (18 x 23)CB002 (12 x 23)CB003 (12 x 23) CB003 (12 x 23) CB001 (12 x 23) PB118 (40 x 23)PB119 (40 x 23)PB125 (32 x 23)PB102 (24 x 23) PB102 (24 x 23) PB116 (40 x 23)PB117 (40 x 23)PB106 (48 x 23)PB101 (18 x 23)PB101 (18 x 23)PB133 (30 x 23)CB004 (8 x 23)CB001 (12 x 23)PB115 (40 x 23) PB132 (30 x 23)PB101 (18 x 23)PB101 (18 x 23)PB134 (18 x 23)SW-2ASW-3ASW-4A SW-5A SW-6A 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 CB004 (8 x 23)HSS8x4x1/4RAMP UP FROM LEVEL BELOW RAMP UP TO LEVEL ABOVERAMP UPBARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST 18 x 18 18 x 18 18 x 36 18 x 30 18 x 18 18 x 18 18 x 18 18 x 30 RAMP UP RAMP UP CB010 (12 x 23)CB001 (12 x 23)5.9 - SEE NOTE 8 1 S7-03 ____________ 4 S7-02 ____________CB009 (12 x 23)4 S7-02 ____________ (18/34 x 23)(34/18 x 23)PB105 (40 x 23)4 S7-02 ____________ CB004 (8 x 23)CB001 (12 x 23)CB006 (18 x 23)CB006 (18 x 23)CB011 (8 x 23)CB006 (18 x 23)PB135 (18 x 23) SEE ARCH. FOR CONCRETE CURB LOCATIONS, TYP. 12 S3-22 ____________ 12 S3-22 ____________ PB102 (24 x 23) PB102 (24 x 23) 4 S7-02 ____________ ___________9 S4-01 HSS8x4x1/4 HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 7 S3-02 ____________ D.2 T/SLAB= 762'-7" T/SLAB= 765'-0" T/SLAB= 768'-1" T/SLAB= 768'-1" T/SLAB= 765'-6" (NOTE 12) (NOTE 12)(NOTE 12) (NOTE 12) (NOTE 12) BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. 15A S3-22 ____________ 15A S3-22 ____________ 15 S3-22 ____________ 15 S3-22 ____________ 1'-3"1'-3"1'-3"1'-3"15A S3-22 ____________ 15A S3-22 ____________ BARRIER CABLES - SEE ARCH. ___________6 S3-41 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"33'-10"11'-6"13'-6"6'-4"6"18'-2"3'-3"21'-9"6'-2"17'-1"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS. 12. T/SLAB ELEVATIONS SHOWN FOR LEVEL 5. SEE T/SLAB ELEVATION TABLE ON THIS SHEET FOR CORRESPONDING ELEVATIONS AT LEVELS 6 AND 7. 3 A A A.3 2.8 2.8 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:11:58 PMS1−05 08.14.18LEVEL 5 − P5 TO 7 − P7 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 5 - P5 TO 7 - P7 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION CORRESPONDING T/SLAB ELEVATIONS LEVEL 5 - P5 762'-7" 765'-0" 765'-6" 768'-1" LEVEL 6 - P6 772'-7" 775'-0" 775'-6" 778'-1" LEVEL 7 - P7 782'-7" 785'-0" 785'-6" 788'-1"0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 2 LEVEL 7 - P7 PARTIAL FRAMING PLAN 08/14/18 S17S20 S21S22S22S23S24S3S19S3S18S10S11S9S25S25S11 S9 S9 S16 S10 S11 S17 SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS. 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 B.1 7.1 SW-1ASW-2ASW-3ASW-4A SW-5A SW-6AHSS8x4x1/4HSS8x4x1/4 HSS8x4x1/45.9 1'-4"PB120 (44 x 23)PB113 (40 x 23)PB114 (40 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)PB121 (44 x 23)PB122 (44 x 23)PB131 (48 x 23) PB101 (18 x 23) PB101 (18 x 23)PB123 (44 x 23)PB124 (44 x 23)PB101 (18 x 23) PB103 (36 x 23) PB108 (34 x 23)PB107 (18 x 23) CB007 (18 x 23) PB136 (18 x 23)PB137 (18 x 23)PB106 (48 x 23)PB109 (30 x 23) PB130 (18 x 23)PB101 (18 x 23)PB134 (18 x 23) PB110 (30 x 23)PB111 (30 x 23)PB101 (18 x 23)PB101 (18 x 23)PB101 (18 x 23)CB006 (18 x 23)PB135 (18 x 23)CB006 (18 x 23)PB112 (34 x 23)PB126 (48 x 23)PB127 (48 x 23)PB128 (48 x 23)CB005 (30 x 23) PB106 (48 x 23)PB104 (36 x 23)PB101 (18 x 23)PB101 (18 x 23)CB002 (12 x 23)CB003 (12 x 23) CB003 (12 x 23) CB001 (12 x 23) PB166 (40 x 23)PB167 (40 x 23)PB125 (32 x 23)PB102 (24 x 23) PB102 (24 x 23) PB165 (40 x 23)PB106 (48 x 23)PB101 (18 x 23)CB018 (30 x 23)CB004 (8 x 23)CB001 (12 x 23)CB018 (30 x 23) PB115 (40 x 23) PB132 (30 x 23)PB101 (18 x 23)PB101 (18 x 23)PB134 (18 x 23)CB004 (8 x 23)CB001 (12 x 23)CB010 (12 x 23)CB011 (8 x 23)PB105 (40 x 23)CB009 (12 x 23)PB102 (24 x 23)CB006 (18 x 23)CB006 (18 x 23)CB004 (8 x 23)PB164 (30 x 23)PB102 (24 x 23)PB163 (30 x 23)RAMP UP FROM LEVEL BELOW RAMP UPRAMP UPBARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST BARRIER CABLE ANCHOR POST RAMP UP RAMP UP 1 S7-03 ____________ 4 S7-02 ____________ 4 S7-02 ____________ SEE ARCH. FOR CONCRETE CURB LOCATIONS, TYP. 12 S3-22 ____________ (18/34 x 23)(34/18 x 23)18 x 18 18 x 36 18 x 30 18 x 18 18 x 18 18 x 18 18 x 30 18 x 18 5" ONE-WAY REINF. CONCRETE SLAB - SEE NOTE 8 4 S7-02 ____________ 14 S3-22 ____________ 13 S3-22 ____________ HSS8x4x1/4 HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ D.2 T/SLAB= 792'-7" T/SLAB= 795'-0" T/SLAB= 798'-1" T/SLAB= 798'-1" T/SLAB= 795'-6" T/SLAB= 799'-10 1/2" BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 SEE 2/S3-41 BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. BARRIER CABLES - SEE ARCH. BARRIER CABLE ANCHOR COL. SEE 4/S3-41 BARRIER CABLES - SEE ARCH. 15A S3-22 ____________ 15A S3-22 ____________ 15 S3-22 ____________ 15 S3-22 ____________ 15A S3-22 ____________1'-3"1'-3"1'-3"1'-3"1'-3" 15 S3-22 ____________ 15A S3-22 ____________ BARRIER CABLES - SEE ARCH. ___________6 S3-41 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"8'-10"6"15'-8"5'-9"19'-3"10'-0"4'-3"11'-6"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"33'-10"11'-6"13'-6"6'-4"6"18'-2"3'-3"21'-9"6'-2"17'-1"LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:02 PMS1−08 08.14.18LEVEL 8 − P8 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 8 - P8 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 SW-1ASW-2ASW-3ASW-4A SW-5A SW-6A 5.9 D.2 HSS12x12x3/8 HSS12x12x3/8 HSS12x12x3/8 HSS12x12x3/8 HSS12x12x3/8HSS12x12x3/8 HSS12x12x3/8HSS12x12x3/8HSS12x12x3/8HSS12x12x3/8HSS12x12x3/8HSS12x12x3/8HSS12x12x3/8 HSS12x12x3/8HSS12x12x3/8 T/SLAB EL. = 801'-4" 6 1/4"-LIGHTWEIGHT STUCTURAL CONC. SLAB W/ WWF 6x6-W1.4xW1.4 AND 3" COMPOSITE DECK (6 1/4" TOTAL DEPTH)5'-5 1/4"12'-11 1/2"12'-11 1/2"6'-7 3/4" 13'-0 3/4" 13'-0 3/4" 13'-0 3/4" W10x12 W10x12 W10x12 W10x12 W10x12 W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12W10x12 W10x12W10x12 W10x12 W10x12 W10x12 (12) HSS4x4x1/4 HANGERS W10x128 S3-53 ____________ 8 S3-53 ____________ 8 S3-53 ____________ OPP. HAND 8 S3-53 ____________ OPP. HAND 8 S3-53 ____________ SIM. 8 S3-53 ____________ OPP. HAND 6 S3-53 ____________ 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4" 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:06 PMS1−08.5 08.14.18LEVEL 8.5 − P8.5 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 8.5 - P8.5 FRAMING PLAN 08/14/18 S1S1 S4 S5S6S6S7S8S34S10S11S9S12 S13 S9 S14 S13 S10 S13 S13 S15 S15 S10 S13 S13 S13 S13 S10 S13 S16S16 S10 S13 S10S3S2S3S2 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 SW-1ACB005 (30 x 23) PB006 (48 x 23)PB005 (40 x 23)PB012 (34 x 23)PB011 (30 x 23)PB008 (34 x 23)PB009 (30 x 23)PB010 (30 x 23)PB004 (36 x 23)PB006 (48 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB002 (24 x 23) PB002 (24 x 23) PB002 (24 x 23) PB002 (24 x 23) PB031 (48 x 23) PB001 (18 x 23) PB001 (18 x 23) PB001 (18 x 23) PB001 (18 x 23) PB003 (18 x 23)PB006 (48 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)CB003 (12 x 23) CB003 (12 x 23)CB002 (12 x 23)CB001 (12 x 23) PB032 (18 x 23)PB033 (18 x 23) PB030 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)CB001 (12 x 23)CB004 (8 x 23)CB001 (12 x 23)PB020 (44 x 23)PB021 (44 x 23)PB022 (44 x 23)PB023 (44 x 23)PB024 (44 x 23)PB013 (40 x 23)PB014 (40 x 23)PB015 (40 x 23)PB016 (40 x 23)PB017 (40 x 23)PB018 (40 x 23)PB019 (40 x 23)PB025 (32 x 23)PB026 (48 x 23)PB027 (48 x 23)PB028 (48 x 23)PB007 (18 x 23)SW-2ASW-3ASW-4A SW-5A SW-6A T/SLAB EL. = 811'-3" 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 CB004 (8 x 23)HSS8x4x1/4CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23)CB004 (8 x 23)5.9 (18/34 x 23)(34/18 x 23) - SEE NOTE 8 1 S7-03 ____________ HSS8x4x1/4 CB003 (12 x 23)7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 4 S6-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 4 S6-02 ____________ D.2 16 S3-22 ____________ 16 S3-22 ____________ 16 S3-22 ____________ 16 S3-22 ____________CB019 (24 x 23)CB020 (24 x 23)CB021 (24 x 23)STAIR PLATFORM BELOW - SEE S1-08.5 (12) HSS4x4 HANGERS FOR PLATFORM BELOW - SEE S1-08.5 6 S3-53 ____________ 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4" 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:10 PMS1−09 08.14.18LEVEL 9 − O1 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 9 - O1 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 S1S1 S4 S5S6S6S7S8S3S2S10S11S9S12 S12 S13 S9 S14 S16 S11 S13 S10 S13 S10 S13 S13 S13 S10 S16 S13 S15 S15 S13 S13 S16S10 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 SW-1ASW-2ACB005 (30 x 23) PB006 (48 x 23)PB005 (40 x 23)PB012 (34 x 23)PB011 (30 x 23)PB008 (34 x 23)PB009 (30 x 23)PB010 (30 x 23)PB004 (36 x 23)PB006 (48 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB002 (24 x 23) PB002 (24 x 23) PB002 (24 x 23) PB002 (24 x 23) PB031 (48 x 23) PB001 (18 x 23) PB001 (18 x 23) PB001 (18 x 23) PB001 (18 x 23) PB003 (18 x 23)PB006 (48 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)PB001 (18 x 23)CB003 (12 x 23) CB003 (12 x 23)CB002 (12 x 23)CB001 (12 x 23) PB032 (18 x 23)PB033 (18 x 23) PB030 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)PB029 (18 x 23)CB001 (12 x 23) CB001 (12 x 23)CB004 (8 x 23)CB001 (12 x 23)PB020 (44 x 23)PB021 (44 x 23)PB022 (44 x 23)PB023 (44 x 23)PB024 (44 x 23)PB013 (40 x 23)PB014 (40 x 23)PB015 (40 x 23)PB016 (40 x 23)PB017 (40 x 23)PB018 (40 x 23)PB019 (40 x 23)PB025 (32 x 23)PB026 (48 x 23)PB027 (48 x 23)PB028 (48 x 23)SW-3ASW-4A SW-5A SW-6A 5" ONE-WAY REINF. CONCRETE SLAB HSS8x4x1/4HSS8x4x1/4 CB004 (8 x 23)HSS8x4x1/4HSS8x4x1/4 CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) CB001 (12 x 23) 1 S7-03 ____________ PB007 (18 x 23)(18/34 x 23)(34/18 x 23) - SEE NOTE 8 CB004 (8 x 23)CB001 (12 x 23)CB004 (8 x 23)5.9 T/SLAB EL. = SEE TABLE HSS8x4x1/4 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________ 10 S3-02 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ 4 S6-02 ____________ SEE 10/S3-02, TYP. EA. END SEE 10/S3-02 D.2 16 S3-22 ____________ 16 S3-22 ____________ 16 S3-22 ____________ 16 S3-22 ____________ 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4" 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:15 PMS1−10 08.14.18LEVEL 10−O2 TO 12−O4, 14−O5 TO 16−O7 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 10 - O2 TO 12 - O4, 14 - O5 TO 16 - O7 FRAMING PLAN T/SLAB ELEVATIONS LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 SW-1BSW-2BCB034 (30 x 35)PB220 (40 x 35)PB218 (40 x 35)PB217 (30 x 23)PB214 (40 x 23)PB215 (30 x 23)PB216 (30 x 23)PB219 (36 x 35)PB207 (24 x 23)PB (66 x 72)PB207 (24 x 23)PB208 (24 x 23)PB209 (24 x 35)CB003 (12 x 23) CB003 (12 x 23)CB002 (12 x 23)CB004 (8 x 23) PB205 (18 x 23)PB206 (18 x 23) PB (18 x 72)PB204 (18 x 23)PB204 (18 x 23)CB024 (18 x 23)CB024 (18 x 23)CB003 (12 x 23) CB003 (12 x 23)CB004 (8 x 23)CB003 (12 x 23)PB (30 x 72)PB (30 x 23)PB (30 x 72)PB213 (24 x 23)PB (66 x 72)PB (76 x 72)PB210 (18 x 23)PB (66 x 72)PB211 (18 x 23)T/SLAB EL. = 915'-1" 5" ONE-WAY REINF. CONCRETE SLAB SW-3BSW-4B SW-5B SW-6B COLUMN STARTS T/SLAB EL. = 910'-1" 12" TWO-WAY PT CONCRETE SLABHSS8x4x1/4CB004 (8 x 23)HSS8x4x1/4 CB003 (12 x 23) CB003 (12 x 23) CB003 (12 x 23) CB003 (12 x 23) CB023 (24 x 23) CB023 (24 x 23) (TYP, U.N.O.)CB032 (30 x 23)CB027 (30 x 23)CB028 (30 x 23)CB030 (30 x 23)CB029 (30 x 23)CB024 (18 x 23)CB024 (18 x 23)CB024 (18 x 23)CB022 (18 x 23)CB031 (30 x 23)T/SLAB EL. = 915'-1" 10" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLAB COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS CB003 (12 x 23) CB003 (12 x 23) COLUMN STARTS COLUMN STARTS 5.9CB025 (18 x 30)CB025 (18 x 30)CB025 (18 x 30)CB025 (18 x 30)T/SLAB EL. = 915'-8" 6" ONE-WAY REINF. CONCRETE SLAB @ POOL BOX 2'-6"PB203 (18 x 23)PB203 (18 x 23)PB203 (18 x 23)CB022 (18 x 23)CB022 (18 x 23)PB202 (18 x 23)PB202 (18 x 23)PB202 (18 x 23)T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLABPB201 (18 x 23)PB201 (18 x 23)PB201 (18 x 23)CB024 (18 x 23)CB024 (18 x 23)CB026 (18 x 53)2'-6"2'-6"PB207 (24 x 23)PB212 (18 x 23)CB026 (18 x 53) 2'-6"2'-6" CB022 (18 x 23) 2'-6"2'-6"HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01 T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 912'-7" 5" ONE-WAY REINF. CONCRETE SLAB CB033 (18 x 35)PB (66 x 72)CB004 (8 x 23) (24/40 x 23)(40/24 x 35) T/BEAM = 915'-1" f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI f'c = 7,000 PSI CB003 (12 x 23)2 S3-53 ____________ 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________SEE 10/S3-02, TYP. EA. END SEE 10/S3-02 D.2 16 S3-22 ____________ 16 S3-22 ____________ SEE 4/S6-02 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4" 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 28'-6"15'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"2 S7-03 ____________ TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BMOPENING INTRANSFER BMOPENING INTRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN TRANSFER BM OPENING IN 13 S3-53 ____________ 13 S3-53 ____________ SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:17 PMS1−17 08.14.18LEVEL 17 INTERSTITIAL FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 17 INTERSTITIAL FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF 7 C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 SW-1BT/SLAB EL. = 923'-10" 12" TWO-WAY PT CONCRETE SLAB SW-2BSW-3BSW-4B SW-5B SW-6B PB (48 x 165/177)PB (48 x 165)PB (30 x 177/171)CB (30 x 165/177) PB (24 x 177) PB (30 x 177/171) PB (24 x 165/177)PB (30 x 177)PB (30 x 165/177)PB (30 x 177/171) CB044 (12 x 20) CB044 (12 x 20) CB045 (8 x 20)CB043 (12 x 20)HSS8x4x1/4CB045 (8 x 20)COLUMN STARTS PB (36 x 146/158)12"12"CB041 (30 x 23)CB (30 x 116)CB036 (30 x 23)CB037 (30 x 23)CB038 (30 x 23)CB039 (30 x 23)PB (30 x 116/146)CB (24 x 116)PB (24 x 116) PB (24 x 116) PB226 (18 x 23)PB227 (18 x 23) 5 S3-61 PB221 (18 x 23) PB221 (18 x 23) PB221 (18 x 23) CB035 (18 x 23) T/SLAB EL. = 922'-10" 12" ONE-WAY PT CONCRETE SLAB T/SLAB EL. = 922'-10" 8" ONE-WAY REINF. CONCRETE SLABCB (18 x 23)COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS T/SLAB EL. = 922'-10" 12" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 922'-10" 8" ONE-WAY REINF. CONCRETE SLAB T/SLAB EL. = 922'-10" 8" ONE-WAY REINF. CONCRETE SLAB PB222 (36 x 20)PB223 (36 x 20)CB040 (30 x 23)CB042 (18 x 20)5.9CB (24 x 116)12"CB045 (8 x 20)HSS5x5x1/4 HSS5x5x1/4 HSS5x5x1/4 HSS5x5x1/4 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ D.2 3 S3-53 ____________ 3 S3-53 ____________ 3 S3-53 ____________ 3 S3-53 ____________ 3 S3-53 ____________ 4 S3-53 ____________4 S3-53 ____________ 4 S3-53 ____________6"6"6" HATCHING INDICATES TOPPING OR RAISED SLAB. SEE 1/S3-01PB225 (36 x 20)PB224 (36 x 20)9 S3-53 ____________ 9 S3-53 ____________ 10 S3-53 ____________11 S3-53 ____________ 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 1'-4" 12 S3-53 ____________ 13 S3-53 ____________ 13 S3-53 ____________ SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. "SR#" INDICATES STUDRAIL REINFORCING. SEE FOR STUDRAIL DETAILS AND SCHEDULE. 10. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9/S3-12 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:20 PMS1−18 08.14.18LEVEL 18 AMENITY − R1 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 18 AMENITY - R1 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF 7 C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 5.9 D.2 11 243K 216K 432K 6 11 11 11 11 11 8 6 1 3 3 3 1 5 270K 6 111 6 1111 SEE FOR ADD'L REINFORCING AT HORIZ. P.T. DEVIATIONS (TYP.) 4/S3-12 8.5 11 64.54.5Fe=54KFe=108KFe=54KFe=54KFe=54KFe=54KFe=162K6666666666666666666666666666666666666666666666666666666666666666Fe=54KFe=54KFe=54KFe=54K444466644446666666666666666666666666666666666663333333336333333333666666666666Fe=27KFe=54K66666666666666SEE AT OPENINGS (TYP.) 10/S3-1266 6111111111111111111111111111111111111113.5 1111611111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111115555533333333333333333333333333333333333111111111111111111111111111111333333333311111311111111111111111155555Fe=18K/FT Fe=18K/FT66666666666Fe=21K/FT 6666666666666666666666666666666666666666666666611111111111111111111111111111111111111111111111111111111166666666666486K Fe=54K111111111111111111111111111111111111111111111111111111111111111111111111111111555555555555555554K 11 3.5 6 1 6666666666666666243K 3 11 11 11 11 366666666666666666666666666666666666666666666666666666666666666666666666666666666666 555555111111111111111111111111111111111111111111111111111151111111111111111111111111111111111111111111111111111111111111111111111111111111333333333333333331111111111111111111111111111111111111161111111111111111111111111111133111111111111111111111111111111111111111111111111111111111111111111111177775553331111111111111111111111111111111111111111Fe=12K/FT3 155555555555555555555555555555555555222222222222222222222222222222222222222222222222222222222222222222222222222222222222263111133111133111133111133Fe=27K/FT Fe=18K/FT Fe=27K/FT 33331111111111311Fe=54K6 3 3 6 6 11 1 11 Fe=162K324K 23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 1'-4" SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES 2. SEE S3-1 SERIES FOR TYPICAL POST-TENSIONED SLAB DETAILS AND TENDON PROFILES. 3. "Fe=#" INDICATES REQUIRED EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES. 4. INDICATES DISTANCE BETWEEN TENDON CENTER OF GRAVITY (CGS) AND SLAB/DROP PANEL SOFFIT. 1 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:29 PMS1−18P 08.14.18LEVEL 18 AMENITY − R1 P.T. REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 18 AMENITY - R1 P.T. REINFORCEMENT PLAN 08/14/18 1 1 8 8234 5 5 6 A A B E.0.7 FF 7 C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.8 7.8 5.8 6.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4 D.4 B.1 7.1 5.9 D.2 9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T4#5x13'-0"T 9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T 9#5x13'-0"T 9#5x13'-0"T9#5x13'-0"T3#5x21'-0"T 9#5x13'-0"T #4@9"TEMP#4x7'-0"@12"T#5@12"T#5x8'-0"@12"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T 9#5x8'-6"T 9#5x21'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T 4#5x23'-0"T&B 4#5x23'-0"T&B 4#5x13'-0"T&B 4#5x13'-0"T&B4#5x13'-0"T&B2#5x5'-0"@4" MID-DEPTH (TYP. AT CORNERS OF OPENINGS) SEE FOR REINF. AT OPENINGS (TYP.) 10/S3-12 2#4x3'-0" AT CORNERS OF SHEARWALLS (TYP.) #4x14'-6"@12"T EXCEPT AT COLUMN ZONE #4x14'-6"@9"T #4x7'-0"@12"T #4x7'-0"@12"T 12#4x93'-0"@9"T&B (ALT) #4@9" TEMP #4x11'-0"@12"B#5x9'-0"@12"B#4@9"TEMP #4@12"T#4@12"B4#5x27'-6"B 2#5x18'-0"B 5#5x29'-0"B4#5x23'-6"B4#5x25'-0"B4#5x13'-6"B4#5x10'-0"TTYP.5'-0"4#5x10'-0"T4#5x10'-0"T4#5x29'-6"BADDITIONAL SLAB CORNER REINFORCEMENT PER (TYP.)5/S3-01 #5x26'-6"@12"B#5x7'-6"@12"B#5x28'-0"@12"B#5x25'-6"@12"B#5x23'-6"@12"B#5x14'-0"@12"T#5x12'-6"@12"T#5x12'-6"@12"T#5x28'-0"@12"B#5x28'-0"@12"B#5x18'-6"@12"B#5x7'-0"@12"T#4@9" TEMP 5'-0"#5x7'-0"@6"T#4x9'-0"@12"B#4x9'-0"@12"B#5x17'-0"@6"B#5x7'-6"@6"T#4@12" TEMP #4@12" TEMP #5x7'-6"@6"T#5x7'-0"@12"T#4@9" TEMP 5'-0"#4x10'-6"@6"B#4x18'-6"@6"T#4x18'-0"@6"T#4x23'-0"@6"T#4x11'-0"@12"B#4x11'-0"@12"B#4x11'-0"@12"B#4x9'-6"@6"B#4x15'-6"@9"T#4x8'-0"@12"T#4x8'-0"@12"B#4x9'-6"@12"B#4@12" TEMP #5x18'-0"@12"T #5x9'-6"@12"B #5x12'-0"@12"T#4@12" TEMP5'-0" #4@12" TEMP #4@12" TEMP #4@12" TEMP #4@12" TEMP #4@12" TEMP #5x14'-0"@12"T #5x12'-6"@6"B #4@12" TEMP#4@9" TEMP #4x21'-0"@9"T5'-0"#5x8'-0"@12"T #5x14'-0"@12"T #5x12'-6"@6"B #5x8'-0"@12"T#5@12"B#5x7'-0"@12"T#5@12"B#5x19'-6"@9"T 6#5x19'-0"T6#5x19'-6"T #5x19'-0"@12"T 9#5x14'-0"T#5x14'-0"@9"T#5x14'-0"@9"T3#5x21'-0"T #5x19'-6"@9"T 6#5x19'-0"T 6#5x19'-6"T #5x19'-0"@12"T #5x12'-0"@12"T#5x8'-0"@12"T#5x8'-0"@12"T#4@9" TEMP 4#5x10'-0"T 4#5x10'-0"T#5x11'-6"@12"T#5x11'-0"@12"B#4@12"T#4@12"B#4@9" TEMP #4@9" TEMP2'-0"#4@12"T#4@12"B#4@9"TEMP 5'-0" TYP. #4@9"TEMP #4@9"TEMP#5x6'-6"@12"T#4@9"TEMP #4@9"TEMP 4#4x53'-6"@9"T&B (ALT) 1#4T 4#5x10'-0"T4#5x10'-0"T #4x14'-6"@9"T EXCEPT AT COLUMN ZONE #4x14'-6"@9"T EXCEPT AT COLUMN ZONE #4x14'-6"@9"T #5x14'-6"@12"B#5x5'-6"@9"T#5x5'-6"@9"T2#4@9"T&B (ALT) #4x14'-6"@9"T #5x8'-6"@12"TEXCEPT AT COLUMN ZONES#5x13'-6"@12"B23'-11"22'-3" 2'-9" 25'-0"25'-0" 2'-6" 21'-10" 8"1'-2"23'-10"21'-1"1'-4"6'-4"25'-0"14'-0"9'-11"1'-1"25'-0"5'-9"19'-3"10'-0"4'-3"11'-6"33'-10"11'-6"13'-6"25'-0"3'-3"21'-9"6'-2"17'-1"26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 1'-4" SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-1 SERIES SHEETS FOR TYPICAL DETAILS. 3. "T" INDICATES TOP MILD REINFORCING AND "B" INDICATES BOTTOM MILD REINFORCING. SEE 1/S3-11 FOR LENGTH, UNLESS NOTED ON PLAN, AND FOR PLACING DETAIL.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:33 PMS1−18R 08.14.18LEVEL 18 AMENITY − R1 REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 18 AMENITY - R1 REINFORCEMENT PLAN 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 SW-1BSW-2BSW-3BSW-4B SW-5B T/SLAB EL. = 935'-10" 8" TWO-WAY PT CONCRETE SLAB CB003 (12 x 23) CB003 (12 x 23)HSS8x4x1/4SR-1 SR-3 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"LB (18 x 30)7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ SR-4 SR-4 D.2D.2 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"21'-10" 1'-10" 22'-3"22'-8" 7" 9" SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "SR#" INDICATES STUDRAIL REINFORCING. SEE FOR STUDRAIL DETAILS AND SCHEDULE. 8. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9/S3-12 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:36 PMS1−19 08.14.18LEVEL 19 − R2 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 19 - R2 FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 5 5 7 C D E.1 D.7 E.2 5.85.7 5.7 B.8B.8 6.7 7.1 21'-10" 1'-10" 22'-3"31'-10"21'-10"28'-2" 3'-6" D.2D.2 270K 189K 7 7 7 7 4 7 4 7 4 1 1 1 7 1 7 1 1 Fe=108KFe=108K44474444444444444444777711117 444444444477777777777777771111111111111111777777777777777477777777777777777777777777777777777741111177477777777777777777777Fe=27K486K 54K 189K 77777777777777777777744411111111111111111111114'-9"7'-8 155/256"16'-1 101/256"3'-7"25'-0"3'-3"5 5 7 C D E.1 D.7 E.2 5.85.7 5.7 B.8B.8 6.7 7.1 D.2D.2 21'-10" 1'-10" 22'-3"31'-10"6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T4#5x10'-0"T 13#5x13'-0"T#4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T #4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T #4@12"T2#5x13'-0"T 4#5x13'-0"T2#5x8'-6"T6#5x8'-6"T 8#4x25'-0"@12"T&B (ALT)10#4x33'-6"@12"T&B (ALT)10#4x32'-0"@12"T&B (ALT)8#4x32'-6"@12"T&B (ALT) #4x13'-6"@12"B #4x14'-0"@12"B #4@12"B2#5x9'-6"T&B 2#5x6'-0"T&B #4@12"TEMP #4@12"T#4@12"B4#5x27'-6"B 2#5x18'-0"B 4#5x27'-6"B 2#5x18'-0"B 4#5x29'-0"B4#5x10'-0"T 4#5x10'-0"T 4#5x10'-0"T3#4x10'-0"@12" T&B (ALT) 6#5x13'-0"T6#5x13'-0"T#4x12'-0"@12"B4#5x10'-0"T #4x7'-6"@12"B4#4x17'-6"@12" T&B (ALT)7#4x11-6"@12"T&B (ALT)4'-9"7'-8 155/256"16'-1 101/256"3'-7"25'-0"3'-3"21'-10"28'-2" 3'-6" SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES 2. SEE S3-1 SERIES FOR TYPICAL POST-TENSIONED SLAB DETAILS AND TENDON PROFILES. 3. "Fe=#" INDICATES REQUIRED EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES. 4. INDICATES DISTANCE BETWEEN TENDON CENTER OF GRAVITY (CGS) AND SLAB/DROP PANEL SOFFIT. 1 SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-1 SERIES SHEETS FOR TYPICAL DETAILS. 3. "T" INDICATES TOP MILD REINFORCING AND "B" INDICATES BOTTOM MILD REINFORCING. SEE 1/S3-11 FOR LENGTH, UNLESS NOTED ON PLAN, AND FOR PLACING DETAIL.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:41 PMS1−19PR 08.14.18LEVEL 19 − R2 PARTIAL REINFORCEMENT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 19 - R2 PARTIAL P.T. REINFORCEMENT PLAN 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 2 LEVEL 19 - R2 PARTIAL REINFORCEMENT PLAN NOTE: SEE S1-20R FOR REINFORCEMENT NOT SHOWN. NOTE: SEE S1-20P FOR P.T. REINFORCEMENT NOT SHOWN. Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 SW-1BSW-2BSW-3BSW-4B SW-5B CB003 (12 x 23) CB003 (12 x 23)HSS8x4x1/426'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9" 21'-10" 1'-10" 22'-3"22'-8" 7" 9" 8" TWO-WAY PT CONCRETE SLAB 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ SR-2 SR-1 D.2D.2 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"26'-8"4'-9"7'-8 155/256"16'-1 101/256"3'-7"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "SR#" INDICATES STUDRAIL REINFORCING. SEE FOR STUDRAIL DETAILS AND SCHEDULE. 8. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9/S3-12 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:45 PMS1−20 08.14.18LEVEL 20 − R3 TO 28 − R11 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 20 - R3 TO 28 - R11 FRAMING PLAN T/SLAB ELEVATIONS LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 189K 216K 270K 405K 189K 162K 7 189K 432K 405K 378K 486K 216K 270K 189K 189K 54K 216K 216K 7 7 7 7 4 4 7 4 7 4 7 7 7 7 7 7 7 7 7 7 7 7 4 47 7 4 4 4 7 4 4 4 7 7 4 7 4 7 4 4 2 1 1 1 4 4 1 2 1 1 2 1 1 1 1 1 1.5 3 1 3.5 3.5 7 1 1.5 1 3.5 2.5 2.5 1 1 111 1 1 7 1 7 4 1 1 81K ADD'L Fe=12K/FT Fe=21K/FTFe=108KFe=108KFe=162KFe=54KFe=108KFe=108KFe=81KFe=108KFe=108K2.51111111111111111111111111111114444444444444444444444444444444444444444444444447744444444444444447777777777777777777777777777777777777777777777777777777774444444444444444444444444444444444444444444444444444444444444444444444442.52.52.52.52.52.52.51111111111111111111111111111111111111111111111111111111111111111411111111111111111111111111111111111111111114444444444444444444444477777777777777777777777777777777777777777777777777777777777771111111111111111111111111 7 444444444477777777777777777777777111111111111111111111117777777777777777777777477777777444444444444444444444444444444444444111111111111111111111111111111111177777777777777777777777777777777777777777777777741111111111111111111111111111111111777711Fe=54KFe=54KFe=54KFe=81KFe=54KFe=54KFe=54K44444444444444444444411111111111111111111147777777777777777777777777777Fe=189KFe=54KFe=27KSEE FOR ADD'L REINFORCING AT HORIZ. P.T. DEVIATIONS (TYP.) 4/S3-12 SEE AT OPENINGS (TYP.) 10/S3-12 23'-8"22'-3"22'-8" 7" 9"77777777772.52.52.52.52.52.51111111111111Fe=54KD.2D.2 54K 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES 2. SEE S3-1 SERIES FOR TYPICAL POST-TENSIONED SLAB DETAILS AND TENDON PROFILES. 3. "Fe=#" INDICATES REQUIRED EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES. 4. INDICATES DISTANCE BETWEEN TENDON CENTER OF GRAVITY (CGS) AND SLAB/DROP PANEL SOFFIT. 1 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:53 PMS1−20P 08.14.18LEVEL 20 − R3 TO 28 − R11 P.T. REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 20 - R3 TO 28 - R11 P.T. REINFORCEMENT PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 8#5x13'-0"T6#5x13'-0"T8#5x13'-0"T6#5x13'-0"T8#5x13'-0"T6#5x13'-0"T4#5x13'-0"T 6#5x13'-0"T8#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T10#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T6#5x13'-0"T 4#5x10'-0"T 13#5x13'-0"T6#5x13'-0"T 6#5x13'-0"T 6#5x13'-0"T 6#5x13'-0"T 6#5x13'-0"T6#5x13'-0"T6#5x19'-6"T 6#5x19'-6"T 6#5x13'-0"T 6#5x13'-0"T6#5x13'-0"T3#5x26'-0"T#4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T #4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T#4x7'-0"@12"T#4x7'-0"@12"T#4x13'-0"@12"T 6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T2#5x13'-0"T 6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T 6#5x8'-6"T6#5x21'-6"T6#5x8'-6"T 6#5x8'-6"T 6#5x21'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T6#5x8'-6"T 6#5x8'-6"T 6#5x8'-6"T 6#5x8'-6"T 6#5x8'-6"T 6#5x8'-6"T 6#5x8'-6"T #4x7'-0"@12"T 3#5T4#5x13'-0"T2#5x8'-6"T6#5x8'-6"T 4#5x23'-0"T&B 4#5x23'-0"T&B 4#5x13'-0"T&B 4#5x13'-0"T&B4#5x13'-0"T&B2#5x5'-0"@4" MID-DEPTH (TYP. AT CORNERS OF OPENINGS) SEE FOR REINF. AT OPENINGS (TYP.) 10/S3-12 2#4x3'-0" AT CORNERS OF SHEARWALLS (TYP.) #4x14'-6"@12"T EXCEPT AT COLUMN ZONES #4x14'-6"@12"T EXCEPT AT COLUMN ZONES #4x17'-6"@12"T EXCEPT AT COLUMN ZONES #4x7'-0"@12"T #4x7'-0"@12"T 8#4x25'-0"@12"T&B (ALT)10#4x33'-6"@12"T&B (ALT)1#4x22'-0"T&B8#4x32'-0"@12"T&B (ALT)8#4x32'-6"@12" T&B (ALT) #4x10'-0"@12"B #4x14'-6"@12"B #4x11'-0"@12"B#4x13'-6"@12"B #4x14'-0"@12"B #4x12'-0"@12"B2#5x8'-6"T&B 2#5x6'-0"T&B #4@12"TEMP #4@12"T#4@12"B26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"4#5x27'-6"B 2#5x18'-0"B 4#5x27'-6"B 2#5x18'-0"B 4#5x27'-6"B 2#5x18'-0"B 4#5x24'-0"B3#5x16'-0"B4#5x24'-6"B 4#5x26'-6"B 5#5x29'-0"B4#5x23'-6"B4#5x18'-6"B4#5B4#5x25'-0"B4#5x25'-0"B4#5x29'-0"B4#5x12'-6"B4#5x24'-6"B4#5x13'-6"B8#4x32'-6"@12"T&B (ALT)10#4x32'-6"@12"T&B (ALT)4#5x10'-0"TTYP.5'-0"4#5x10'-0"T4#5x10'-0"T 4#5x10'-0"T 4#5x10'-0"T4#5x27'-6"B4#5x29'-6"B3#4x10'-0"@12" T&B (ALT) ADDITIONAL SLAB CORNER REINFORCEMENT PER (TYP.)5/S3-01 6#5x13'-0"T6#5x13'-0"TD.2D.2 4#5x10'-0"T26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9" 21'-10" 1'-10" 22'-3"22'-8" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-1 SERIES SHEETS FOR TYPICAL DETAILS. 3. "T" INDICATES TOP MILD REINFORCING AND "B" INDICATES BOTTOM MILD REINFORCING. SEE 1/S3-11 FOR LENGTH, UNLESS NOTED ON PLAN, AND FOR PLACING DETAIL.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:12:57 PMS1−20R 08.14.18LEVEL 20 − R3 TO 28 − R11 REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 20 - R3 TO 28 - R11 REINFORCEMENT PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 SW-1BSW-2BSW-3BSW-4B SW-5B HSS8x4x1/4SEE S1-20P & S1-20R FOR P.T. & MILD STEEL REINFORCEMENT T/SLAB EL. = 1037'-6" 8" TWO-WAY PT CONCRETE SLAB 7 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ CB003 (12 x 23) SR-2 SR-1 CB003 (12 x 23) D.2D.2 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 17 S3-22 ____________ 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"21'-10" 1'-10" 22'-3"22'-8" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "SR#" INDICATES STUDRAIL REINFORCING. SEE FOR STUDRAIL DETAILS AND SCHEDULE. 8. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9/S3-12 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:00 PMS1−29 08.14.18LEVEL 29 − R12 FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 29 - R12 FRAMING PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 SW-1BSW-2BSW-3BSW-4B SW-5B HSS8x4x1/48" CONCRETE CURB - SEE ARCH. FOR CURB HEIGHT FRAME TYPE "B" (TYP.) FRAME TYPE "A" (TYP.) (SIM.) ___________1 S3-51 CB003 (12 x 23) CB003 (12 x 23) COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS COLUMN STARTS SEE 2/S3-51 SEE 2/S3-51 FRAME TYPE "A" (TYP.) (SIM.)SEE 2/S3-51 T/SLAB EL. = Varies 12" TWO-WAY PT CONCRETE SLAB 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE 12" DIA. SLEEVE T/SLAB= 1049'-6" HSS8x8x5/8 HSS8x8x5/8 HSS8x8x5/8HSS8x8x5/8HSS8x8x5/8HSS8x8x5/8HSS8x8x5/8HSS8x8x5/8HSS8x8x5/8HSS8x8x5/87 S3-02 ____________10 S3-02 ____________ 7 S3-02 ____________ D.2D.2 SLOPESLOPESLOPE SLOPE SLOPE SLOPE 18 S3-22 ____________ 18 S3-22 ____________ 18 S3-22 ____________ 18 S3-22 ____________ 18 S3-22 ____________ 18 S3-22 ____________ 18 S3-22 ____________ 5 S3-53 ____________ TYP. HSS4x4x1/4 BRACE HSS4x4x1/4 BRACEHSS4x4x1/4 BRACE26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"21'-10" 1'-10" 22'-3"22'-8" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "SR#" INDICATES STUDRAIL REINFORCING. SEE FOR STUDRAIL DETAILS AND SCHEDULE. 8. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 9/S3-12 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:03 PMS1−30 08.14.18ROOF LEVEL FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 ROOF LEVEL FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 D.2D.2 243K 11 243K 11 11 11 1163.5 3 3 3 6 243K 486K 6 11 11 11 11 11 8 6 1 3 3 3 1 5 243K 6 111 3.5 513K 513K 6 11 11 11 611 11 1 1.5 4.5 1 41 11 SEE FOR ADD'L REINFORCING AT HORIZ. P.T. DEVIATIONS (TYP.) 4/S3-12 216K 162K 270K 6 11 11 11 666 6 11 1.5 1108K ADD'L 432K 216K 216K 11 6 11 6 4 11 1 1 594K 270K 270K 6 6 11 6 6 2.5 2.5 1 1 11 3 54K 324K 6 11 11 6353Fe=54KFe=54KFe=108KFe=54KFe=54KFe=54KFe=54KFe=135KFe=54K666666666666666666666666666666666666666666666666666666666666666666111166Fe=81KFe=108KFe=189KFe=54KFe=54KFe=54KFe=54KFe=54KFe=54KFe=27KFe=54K6666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666Fe=27KFe=54K6666666666666666SEE AT OPENINGS (TYP.) 10/S3-126 6665.55.55.55.55.55.55.55.55.55.511111111111111111111111111111111111111111111111111111111111111111111113.5 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111122222222222222222222222222222222222222222222222222222222222222222222222222222222222211111111111111111111111111111111111111111111111111111111111111111181111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111666663333333333333333333333333333333333333311111111111111111111111111111333333333333331111111111111111111111111111111115.55.55.55.55.55.55.55.55.55.5111111111111111111111111111111111111111111111111111111111133333333333333333333333333333333311111111111111111111111111111111111111111111111111111111111111111111111111111111111166666611111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111333333333333331111111111111111111111111111111111111111111111111111111111111111111111111111111111Fe=18K/FT Fe=18K/FT 26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"21'-10" 1'-10" 22'-3"22'-8" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES 2. SEE S3-1 SERIES FOR TYPICAL POST-TENSIONED SLAB DETAILS AND TENDON PROFILES. 3. "Fe=#" INDICATES REQUIRED EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES. 4. INDICATES DISTANCE BETWEEN TENDON CENTER OF GRAVITY (CGS) AND SLAB/DROP PANEL SOFFIT. 1 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:11 PMS1−30P 08.14.18ROOF LEVEL P.T. REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 ROOF LEVEL P.T. REINFORCEMENT PLAN 08/14/18 1 8 8234 5 5 6 AA BB F 7 B.2 B.9 C D E.1 A.3 D.7 E.2 7.8 7.8 5.8 A.7 C.7.1 D.0.5 2.8 5.7 5.7 B.8B.8 B.1 A.1A.1 7.9 7.9 6.7 C.2 7.1 D.2D.2 9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T 4#5x10'-0"T 13#5x13'-0"T9#5x13'-0"T 9#5x13'-0"T 9#5x13'-0"T 9#5x13'-0"T 9#5x13'-0"T9#5x13'-0"T9#5x19'-6"T 9#5x19'-6"T 9#5x13'-0"T 9#5x13'-0"T9#5x13'-0"T5#5x26'-0"T#4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T #4x13'-0"@12"T #4x7'-0"@12"T #4x7'-0"@12"T#4x7'-0"@12"T#4x7'-0"@12"T#4x13'-0"@12"T 9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T2#5x13'-0"T 9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T 9#5x8'-6"T9#5x21'-6"T9#5x8'-6"T 9#5x8'-6"T 9#5x21'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T9#5x8'-6"T 9#5x8'-6"T 9#5x8'-6"T 9#5x8'-6"T 9#5x8'-6"T 9#5x8'-6"T 9#5x8'-6"T #4x7'-0"@12"T 4#5x21'-6"T4#5x13'-0"T2#5x8'-6"T9#5x8'-6"T 2#5x5'-0"@4" MID-DEPTH (TYP. AT CORNERS OF OPENINGS) SEE FOR REINF. AT OPENINGS (TYP.) 10/S3-12 2#4x3'-0" AT CORNERS OF SHEARWALLS (TYP.) #4x14'-6"@12"T EXCEPT AT COLUMN ZONES #4x14'-6"@12"T EXCEPT AT COLUMN ZONES #4x17'-6"@12"T EXCEPT AT COLUMN ZONES 10#4x25'-0"@9"T&B (ALT)14#4x33'-6"@9"T&B (ALT)4#4x22'-0"@9"T&B (ALT)8#4x32'-0"@9"T&B (ALT)10#4x32'-6"@9" T&B (ALT) #4x10'-0"@12"B #4x14'-6"@12"B #4x11'-0"@12"B#4x13'-6"@12"B #4x14'-0"@12"B #4x12'-0"@12"B2#5x8'-6"T&B 2#5x6'-0"T&B #4@12"TEMP #4@12"T#4@12"B4#5x27'-6"B 2#5x18'-0"B 4#5x27'-6"B 2#5x18'-0"B 4#5x27'-6"B 2#5x18'-0"B 4#5x24'-0"B3#5x16'-0"B4#5x24'-6"B 4#5x26'-6"B 5#5x29'-0"B4#5x23'-6"B4#5x18'-6"B4#5x12'-0"B5#5x25'-0"B5#5x25'-0"B4#5x29'-0"B4#5x12'-6"B4#5x24'-6"B4#5x13'-6"B10#4x32'-6"@9"T&B (ALT)14#4x32'-6"@9"T&B (ALT)4#5x10'-0"TTYP.5'-0"4#5x10'-0"T4#5x10'-0"T 4#5x10'-0"T 4#5x10'-0"T4#5x27'-6"B 3#4x10'-0"@12" T&B (ALT) ADDITIONAL SLAB CORNER REINFORCEMENT PER (TYP.)5/S3-01 9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T9#5x13'-0"T4#5x10'-0"T26'-5"19'-9" 5'-3" 25'-0"25'-0"21'-10" 3'-2" 25'-0" 3'-6" 15'-1" 7" 9"26'-8"4'-9"7'-8 155/256"19'-8 101/256"25'-0"3'-3"21'-9"6'-2"15'-6"1'-7"21'-10" 1'-10" 22'-3"22'-8" 7" 9"2'-4"10'-6"12'-0"5'-0"2'-0"16'-6"2'-9"2'-6"11'-9"9'-11"1'-7"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-1 SERIES SHEETS FOR TYPICAL DETAILS. 3. "T" INDICATES TOP MILD REINFORCING AND "B" INDICATES BOTTOM MILD REINFORCING. SEE 1/S3-11 FOR LENGTH, UNLESS NOTED ON PLAN, AND FOR PLACING DETAIL.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:14 PMS1−30R 08.14.18ROOF LEVEL REINFORCEMENT PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 ROOF LEVEL REINFORCEMENT PLAN 08/14/18 S16S13S10S16 S13 S10 S34 S26 5 65.7 B.8 SW-2BSW-3BSW-4B SW-5BCB003 (12 x 23)CB003 (12 x 23)CB047 (12 x 23)CB048 (12 x 23)CB003 (12 x 23)CB048 (12 x 23)CB047 (12 x 23)6.4 21'-10" 11'-11" T/SLAB EL. = 1061'-9" 5" ONE-WAY REINF. CONCRETE SLAB CB003 (12 x 23) CB003 (12 x 23)W8x24W8x24W8x24HOIST BEAMHOIST BEAMHOIST BEAMCB046 (6 x 23) CB004 (8 x 23)CB (8 x 23)D.2 - SEE NOTE 8 31'-10"SHEET NOTES: 1. SEE S0 SERIES SHEETS FOR STRUCTURAL NOTES. 2. SEE S3-0 SERIES SHEETS FOR TYPICAL FRAMING DETAILS. 3. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS NOT SHOWN, SLAB DEPRESSION DEPTHS AND LOCATIONS NOT SHOWN, SLAB SLOPES NOT SHOWN, CONCRETE CURB HEIGHTS AND LOCATIONS NOT SHOWN, AND SLAB AND WALL OPENING SIZES AND LOCATIONS NOT SHOWN. 4. SEE S4 SERIES SHEETS FOR COLUMN DETAILS AND SCHEDULES. 5. "SW-#" INDICATES SHEAR WALL. SEE S5 SERIES SHEETS FOR SHEAR WALL DETAILS AND ELEVATIONS. 6 "CB###(AXB)" INDICATES CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S6 SERIES SHEETS FOR CONCRETE BEAM DETAILS AND SCHEDULES. 7. "PB###(AXB)" INDICATES POST-TENSIONED CONCRETE BEAM A" WIDE BY B" DEEP (DEPTH MEASURED FROM TOP OF SLAB TO UNDERSIDE OF BEAM). SEE S7 SERIES SHEETS FOR POST-TENSIONED CONCRETE BEAM DETAILS AND SCHEDULES. 8. SEE 1/S3-21 FOR TYPICAL SLAB REINFORCING. FOR SLABS NOT TYPICAL, "S#" INDICATES CONCRETE SLAB TYPE (SEE 2/S3-21 FOR DETAILS AND SCHEDULE). 9. INDICATES LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 10. INDICATES NON-LOAD BEARING CMU WALL. SEE S3-3 SERIES SHEETS FOR TYPICAL MASONRY DETAILS. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATIONS. 11. AT PARKING GARAGE SLABS: TOP OF SLAB ELEVATIONS SHOWN FOR REFERENCE. SEE ARCHITECTURAL DRAWINGS FOR TOP OF SLAB ELEVATIONS AND FOR SLOPES TO DRAINS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:17 PMS1−31 08.14.18LEVEL 31 − PENTHOUSE FRAMING PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 0'4' - 0" 8' - 0" 16' - 0" SCALE= 1/8" = 1'-0" 1 LEVEL 31 - PENTHOUSE FRAMING PLAN Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 COLD FORM KEY SEE PLAN"T"1/8" WIDEx0.25T DEEP - SAW CUT JOINT. SPACE PER SCHEDULE SHOWN HERE SEE PLAN"T"CONTRACTION JOINT CONSTRUCTION JOINT SLAB DEPTH "T" MAX JOINT SPACING 4" 12'-0" 5" 15'-0" >6" 18'-0" FIBER REINF. CONCRETE FIBER REINF. CONCRETE3"TYP.3"3"TYP.3"CONCRETE COLUMN WITH 15# FELT WRAP 2#4@3" AT EACH CORNER (TYP.) SAW CUT CONTRACTION JOINTS AS CLOSE TO COLUMN AS POSSIBLE. TOOL THE REMAINDER TO FACE OF COLUMN (TYP.) FELT WRAPPED COLUMNS #4 CONTINUOUS 8"SEE PLAN< 8"4" 8" 4"2"T" SEE PLAN8" TO 24"#4@12" MAX. CONTINUOUS (2 BAR MINIMUM) #4@12" 2#4 CONTINUOUS PLAN"T" SEE2x4 KEY WITH WATERSTOP 24" FIBER REINF. CONCRETE FIBER REINF. CONCRETEHW "W" = LESS THAN 8" (H = 2'-0" MAX.) #4@12" #4@12" (MIN. 1-BAR) ROUGHEN SURFACE HW "W" = 8" OR MORE (H = 2'-0" MAX.) #4@12" E.F. #4@12" E.F. (MIN. 1-ROW) ROUGHEN SURFACE VERIFY "W" & "H" DIMENSIONS WITH ARCH. DRAWINGS 2#4@4"x3'-0" TOP AT CORNERS (TYPICAL)2" EDGE OF SLAB 2#4x4'-0" AT MID DEPTH (TYPICAL) DISCONTINUOUS SLAB ON GRADE JOINTS 4"2"BENT BARS SAME SIZE & QUANTITY AS FOOTING REINFORCING "D" 2("A") - MIN.2'-0" MAX."A""D"TOP REINF. IF REQ'D. NOTE: "D" = FOOTING DEPTH SEE PLAN & SECTIONS LAP (TYP.) CLASS "B" CORNER BARS TO MATCH CONTINUOUS BARS 2' 2' FOOTING - SEE SECTIONS FOR SIZE AND REINF. FOOTING REINF."T"PIPE UNDER FOOTING DIA. 8" MIN.ONE PIPE"T"1'-6" 1'-6""T" MIN.T/WALL FOOTING EXTRA REBAR TO MATCH FOOTING REINFORCING OF PIPE PIPE AT BOTTOM OF FOOTING 2'-0" FOOTING REINF."T"1'-6" 1'-6""T" MIN.T/WALL FOOTING OF PIPE PIPE NEAR TOP OF FOOTING 2'-0" FOOTING REINF.MIN.3"2'-0" 2'-0" 2'-6" 2'-6" EXTRA REBAR TO MATCH FOOTING REINFORCING #4@12" NOTES: 1. COORDINATE PIPE PENETRATION LOCATIONS WITH PLUMBING DRAWINGS. 2. "T" EQUALS WALL FOOTING THICKNESS - SEE SECTIONS. CMU WALL 1'-0"6"6"2#4 CONTINUOUS CMU WALL (8" MAX.)SEE PLAN1'-0"6"6"2#4 CONTINUOUS AT SLAB DEPRESSION FIBER REINF. CONCRETE FIBER REINF. CONCRETE 1/8" WIDEx 1/4x"T" DEEP SAW CUT JOINT FILL FULL DEPTH W/ SEMI- RIGID JOINT FILLER AND JOINT SEALANT PLAN"T" SEECONTRACTION JOINT CONSTRUCTION JOINT1/2 x TSTOP REINFORCING EACH SIDE OF JOINT 3/4" TAPERED PLATE DOWELS @ 30"c/c BASKET ASSEMBLY 1/2 x TPLAN"T" SEEREINFORCING 1/8" WIDEx 1" DEEP SAW CUT JOINT FILL FULL DEPTH W/ SEMI-RIGID JOINT FILLER AND JOINT SEALANT STOP REINFORCING EACH SIDE OF JOINT REINFORCING SLEEVED FLAT PLATE DOWEL SYSTEM @ 20"c/c 1'-0"U.N.O.2'-0"FINISHED GRADE OR T/SLAB- SEE ARCH. AND CIVIL DRAWINGS 3#4 CONTINUOUS FIBER REINF. CONCRETE 6" 1'-0"U.N.O.2'-0"4#4 CONTINUOUS FINISHED EXTERIOR SURFACE (NOT BY SDL)1'-0"#4@24" FIBER REINF. CONCRETE T/SLAB PLAN"T" SEE1'-0" T/SLAB PLAN"T" SEE1'-0" NOTE: OFFSET CONTRACTION JOINT TO AVOID INTERSECTING THICKENED SLAB AREA AT T < 8"AT T > 8"_ SEE PLAN FOR REINFORCING (TOP & BOTTOM) SEE PLAN FOR REINFORCING FIBER REINF. CONCRETE FIBER REINF. CONCRETE 4"8"8"1'-0"PREFORMED JOINT MATERIAL T/SLAB EQUIPMENT PAD - SEE M.E.P. #4@12" EACH WAY (TOP AND BOTTOM) COORDINATE SIZE AND LOCATION WITH M.E.P.CLR.2"FIBER REINF. CONCRETE 3#4 CONT. FOUNDATION WALL 1'-0"PLANSEET/SLAB PREFORMED JOINT FILLER 10"FIBER REINF. CONCRETE 3#4 CONT. FOUNDATION WALL 1'-0"PLANSEET/SLAB T/FOOTING FOUNDATION PREFORMED JOINT FILLER FIBER REINF. CONCRETE 1'-0"1'-4"PLANSEEFUTURE SLAB, COORDINATE WITH TENANT 3"8"FIBER REINF. CONCRETE 3#4 CONT. 4" 8" #4 CONTINUOUS EACH SIDE 2x4 KEY 8" 4" SEE ARCH. T/SLAB SEE ARCH.VARIES4 1/2"#4@12" EACH SIDE L2x2x1/4 CONTINUOUS W/ 1/2" DIA. x6" HEADED ANCHORS @ 18" #4@12" CONTINUOUS SEE ARCH FOR TRENCH COVER 1'-0" #4@12" FIBER REINF. CONCRETE LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:22 PMS2−01 08.14.18TYPICAL FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL SLAB ON GRADE DETAILS 2 TYP. SLAB ON GRADE JOINT DETAIL AT COLUMNS 3 TYPICAL DEPRESSED SLAB ON GRADE DETAILS 4 TYPICAL CONCRETE CURB DETAILS 5 TYPICAL REINFORCING AT RE-ENTRANT CORNERS 6 TYP. REINFORCING AT DISCONTINUOUS JOINTS 7 TYPICAL SECTION AT STEPPED DOWN FOOTING 8 TYPICAL WALL FOOTING INTERSECTION REINFORCING PLAN 9 TYPICAL DETAILS OF WALL FOOTINGS PENETRATED BY PLUMBING LINES 10 TYPICAL THICKENED SLAB ON GRADE DETAILS AT NON-LOAD BEARING WALLS 11 TYPICAL SLAB ON GRADE DETAILS AT LOADING DOCK AND 8" THICK SLABS 12 TYPICAL TURNED DOWN SLAB 13 TYPICAL TURNED DOWN SLAB 14 TYPICAL THICKENED SLAB ON GRADE DETAILS 15 TYPICAL EQUIPMENT PAD ON GRADE SECTION 16 TYPICAL EDGE OF SLAB ON GRADE DETAIL 17 TYPICAL EDGE OF SLAB ON GRADE DETAIL 18 TYPICAL SECTION AT FUTURE SLAB Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 19 TYPICAL TRENCH DRAIN DETAILS 08/14/18 SS ldld2'-0" IF D≤8" 4'-0" IF 8"<D≤14" D S DS1' - 0"2'-0''MAX.FACE OF WALLSOIL CAP GRANULAR BACKFILL WATERPROOFING SEE ARCH. UNDISTURBED SOIL NOTE: SLOPE OF EXCAVATION TO BE DETERMINED BY CONTRACTOR TO MAINTAIN STABILITY OF SOIL. FOUNDATION DRAIN SEE CIVIL OR PLUMBING DRAWINGS 2'-0''60° MAX.FINISHED GRADE OR T/SLAB - SEE ARCH. AND CIVIL DWGS 2'-0''MAX.FACE OF WALLSOIL CAP SOIL BACKFILL WATERPROOFING AND DRAINAGE MAT - SEE ARCH. DWGSUNDISTURBED SOIL NOTE: SLOPE OF EXCAVATION TO BE DETERMINED BY CONTRACTOR TO MAINTAIN STABILITY OF SOIL. FOUNDATION DRAIN SEE CIVIL OR PLUMBING DRAWINGS 2'-0''60° MAX.FINISHED GRADE OR T/SLAB - SEE ARCH. AND CIVIL DWGS ALTERNATE DETAIL CONTINUOUS 2x4 KEY WITH WATERSTOP LAP SPLICE CONSTRUCTION JOINT 3/4"x3/4" VEE JOINT CONTROL JOINT @ 20'-0" MAX. ALTERNATE HORIZONTAL REINFORCING BARS SHALL BE DISCONTINUOUS ACROSS THE JOINT (EACH FACE). CORNERINTERSECTION ENDWALL STANDARD 90° HOOKS 1 VERTICAL BAR TYPICAL 2 VERTICAL BARS TYPICAL SPLICE LAP SPLICELAPL-BARS TO MATCH HORIZONTAL REINF. ALTERNATE BEND #3 HAIRPIN MATCH HORIZ. SPACING CLR 3/4" CLR 3/4" CORNERINTERSECTION ENDWALL SPLICELAPSPLICE LAP U-BARS TO MATCH HORIZONTAL REINF. STANDARD 90° HOOKS 2 VERTICAL BARS TYPICAL U-BARS TO MATCH HORIZONTAL REINF. 2 VERTICAL BARS TYPICAL LINTEL BAR SCHEDULE OPENING SIZE REINFORCING LESS THAN 5'-0" 5'-1" TO 7'-0" 7'-1" TO 9'-0" MORE THAN 9'- 0" 2#5 2#6 2#7 CONSULT ENGINEER FLOOR LINE SPLICELAPSPLICE LAP SPLICELAPACI STANDARD HOOK WHERE MIN. EMBED. IS NOT POSSIBLE DOWELS TO MATCH JAMB BARS JAMB BARS TO MATCH VERT. REINF. LINTEL BARS - SEE SCHEDULE WHERE EXTENSION IS NOT POSSIBLE, EXTEND BARS AS FAR AS POSSIBLE AND PROVIDE STANDARD ACI HOOK FLOOR LINE SPLICELAPTYPICAL WALL REINFORCING JAMB BARS TO MATCH VERT. REINF. WHERE EXTENSION IS NOT POSSIBLE, EXTEND BARS AS FAR AS POSSIBLE AND PROVIDE STANDARD ACI HOOK LINTEL BARS - SEE SCHEDULE LENGTH DEVELOPMENT HAIRPINS TO MATCH HORIZ. REINFORCINGTYP. WALL REINFORCING SECTION C JAMB 1/2 THE INTERRUPTED REINF. EACH SIDE OF OPENING TYP. WALL REINFORCING SECTION D JAMB SPLICE LAP 1/2 THE INTERRUPTED REINF. EACH SIDE OF OPENING U-BARS TO MATCH VERTICAL REINFORCING SECTION E ISOLATED WALL T/OPENINGT/OPENING HAIRPINS TO MATCH VERTICAL REINFORCING B/OPENING B/OPENING SECTION A LINTEL/SILL SECTION B LINTEL/SILL A OR BC OR D A OR BC OR D STANDARD 90° ACI HOOK SPLICELAPLINTEL BARS TYPICAL WALL REINFORCING U-BARS TO MATCH HORIZ. REINFORCING NOTES: 1. S = SPECIFIED VERTICAL REINFORCING SPACING S = SPECIFIED HORIZONTAL REINFORCING SPACING D = OUTSIDE DIAMETER OF WALL PENETRATION 2. MAXIMUM D EQUALS 14" 3. CLUSTERS OF PENETRATIONS NOT MEETING THESE LIMITATIONS SHOULD BE TREATED AS A FRAMED OPENING PER . 4. FOR OTHER CONDITIONS NOT MEETING THE PARAMETERS OF THIS DETAIL CONTACT STRUCTURAL ENGINEER. H V WALL REINF. PER PLANS AND DETAILS12" MIN.FOR PENETRATIONS WITH DIAMETERS "D" ≤ (S OR S ) - 3 INCHESHV FOR PENETRATIONS WITH DIAMETERS "D" ≥ (S OR S ) - 3 INCHESHV12" MIN.WALL REINF. PER PLANS AND DETAILS CUT VERT. AND HORIZ. REINF. AS REQUIRED (2 BARS MAX. PER OPENING) PROVIDE 1 ADDITIONAL HORIZ. BAR ON EACH SIDE OF PENETRATION TO MATCH HORIZ. REINFORCING - EXTEND BAR A DEVELOPMENT LENGTH BEYOND PENETRATION WHERE A DEVELOPMENT LENGTH IS NOT AVAILABLE BELOW PENETRATION - DRILL AND EPOXY ADDITIONAL VERT. BARS INTO FOUNDATION W/ A MINIMUM EMBEDMENT OF 12 BAR DIAMETERS PROVIDE 1 ADDITIONAL VERT. BAR ON EACH SIDE OF PENETRATION TO MATCH VERT. REINFORCING - EXTEND BAR A DEVELOPMENT LENGTH BEYOND PENETRATION T/FOUNDATION T/WALL 8" MIN.HV T/FOUNDATION T/WALL V 1 1/2" MIN. 1 1/2" MIN.8" MIN.H1 1/2"MIN.1 1/2"MIN.5/S2-02 "W" SHAPE COLUMN WITH 15# FELT WRAP 2#4@3"x3'-0" AT EACH CORNER (TYP.) SAW CUT CONTRACTION JOINTS AS CLOSE TO COLUMN AS POSSIBLE. TOOL THE REMAINDER TO FACE OF COLUMN (TYP.) FELT WRAPPED COLUMNS COLUMN, SEE PLAN CONSTRUCTION JOINT OR SAW CUT CONTRACTION JOINT ISOLATION JOINTS AT COLUMNS ISOLATION JOINT WITH PREFORMED JOINT FILLER AT COLUMN ISOLATION JOINT WITH PREFORMED JOINT FILLER AT COLUMN EDGE OF SLAB MIN.3"COLUMN, SEE PLAN CONSTRUCTION JOINT OR SAW CUT CONTRACTION JOINT 3"3" HSS COLUMNS WITH 15# FELT WRAP COLUMN BASE PLATE BELOW SLAB COLUMN BASE PLATE BELOW SLAB MI N. 3" NOTE: ISOLATION OF COLUMNS IS REQUIRED. PROVIDE EITHER ISOLATION JOINTS OR FELT WRAP AT COLUMN (CONTRACTOR'S OPTION)."F""A".THREADED ANCHOR ROD PROJECTION = GROUT + BASE PLATE THICKNESS + ANCHOR ROD DIA. + PLATE WASHER THICKNESS + 1" MIN."D1""D1""B""D2" "D2" "C" "E"GROUT - SEE 9/S2-02HEAVY HEX NUT ASTM F1554 GR. 36 ANCHOR RODS WITH 2 PLATE WASHERS AND 2 HEX NUTS (TYP.) PLATE WASHER SEE 9/S2-02 BASE PLATE & ANCHOR ROD SCHEDULE A B C D1 D2 E F № W COLUMN SIZE BASE PLATE ANCHOR RODS WELD 3" DIA. GROUT HOLES AT PLATES LARGER THAN 24"x24" (TYP.) 1/2" 20" 20" 8" 8" 3/4" 8" 4 3/16"HSS12x8x1/2 SEE 9/S2-02 "Y" "W" 1/2" 16" 16" 6" 6" 3/4" 8" 4 1/4"HSS8x8x5/8 3/4 1 5/16 3 3/8 2 3/16, NOTE 2 ANCHOR ROD DIAMETER (INCHES) MAXIMUM HOLE DIAMETER (INCHES) MINIMUM WASHER WIDTH (INCHES) NOTE 1 MINIMUM WASHER THICKNESS (INCHES) BASE PLATE GROUT (INCHES) WELD, "Y" WASHER TO BASE PLATE (INCHES) 7/8 1 9/16 3 3/8 2 3/16, NOTE 2 1 1 13/16 3 3/8 2 3/16, NOTE 2 1 1/4 2 1/16 3 1/2 3 3/16 1 1/2 2 5/16 3 1/2 1/2 3 3/16 1 3/4 2 3/4 4 5/8 4 1/4 2 3 1/4 5 3/4 4 5/16 2 1/2 3 3/4 5 1/2 7/8 4 5/16 NOTES: 1. PROVIDE SQUARE PLATE WASHERS CONFORMING TO ASTM A36 WITH STANDARD HOLES. 2. WELDS ARE NOT REQUIRED FOR GRAVITY COLUMNS.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:26 PMS2−02 08.14.18TYPICAL FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL BACKFILL AT FOUNDATION WALL 2 TYPICAL DETAIL AT VERT. CONSTRUCTION & CONTROL JOINT FOR CONC. FOUND. WALLS 3 TYPICAL REINFORCING AT WALL INTERSECTIONS SINGLE MAT REINFORCING 4 TYPICAL REINFORCING AT WALL INTERSECTIONS DOUBLE MAT REINFORCING 5 TYPICAL MINIMUM REINFORCING AT CONCRETE WALL OPENINGS 6 TYPICAL SLEEVE PENETRATION LOCATION AND REINFORCING DIAGRAM AT FOUNDATION WALLS 7 TYP. SLAB ON GRADE JOINT DETAIL AT COLUMNS (CONTRACTOR'S OPTION) 8 BASE PLATE AND ANCHOR ROD SCHEDULE 9 PLATE WASHER & GROUT THICKNESS SCHEDULE Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 VERIFY SUMP PIT SIZE w/ MEP DRAWINGS SUMP PIT3/4"ELEVATOR PITVERIFY w/ ELEVATOR MANUFACTURER2'-0"8"1'-0" 1'-0" 1'-6" 2x4 KEY CONTINUOUS 2#5 CONTINUOUS #5 DOWELS @ 12" 2' - 0"1' - 0" #4@12" FIBER REINF. CONCRETE8"1'-0" 1'-0" STRINGER (BY STAIR SUPPLIER) L3x3x1/4 W/ 3/4" DIA. EXPANSION ANCHOR, 4" MIN. EMBEDMENT 2#5 CONTINUOUS BOTTOM #4@12" FIBER REINF. CONCRETE MI N.5" LAP TENSION MIN. 8"MIN.1'-0"FINISHED GRADE OR SLAB - SEE PLAN SEE ARCH. DRAWINGS FOR STAIR PROFILE #3 NOSING BAR (TYP.) FIBER REINF. CONCRETE 2#4 CONTINUOUS #4 BAR AT BOTTOM OF EACH RISER #4@18" #4 CONTINUOUSMIN.5" LAP TENSION MIN. 8"1'-0"MIN.1'-0"4' - 0" MAX.FINISHED GRADE OR SLAB - SEE PLAN SEE ARCH. DRAWINGS FOR STAIR PROFILE #3 NOSING BAR (TYP.) FIBER REINF. CONCRETE #4 CONTINUOUS #4 BAR AT BOTTOM OF EACH RISER #4@18"AA#4@12" E.W. AT CHEEK WALL 3#5 CONTINUOUS BOT. ALTERNATE DOWELS HOOKS MIN. 6"LAP TENSION OR CIVILSEE ARCH.BUILDING OR CHEEK WALL (WHERE REQ.) CONCRETE OR MASONRY #4 DOWELS SECTION A-A 2'-0" FIBER REINF. CONCRETE 1'-0"3#4 E.W. SQUARE 2'-0" BASE PLATE 5/8"x10"x10" W/ (4) 3/4" DIA.. x6" LONG HEADED STUDS @ 6" E.W. HSS3.500x0.216 NOTE: FOR LANDING COLUMN LOCATIONS - SEE ARCH. 3/16 8" 8" #5@12"1'-0"VERIFY WITH ELEVATOR MFRELEVATOR PIT#5@12" CONTINUOUS 2x4 KEY AND WATERSTOP GRANULAR BACKFILL 120° #4@12" T/SLAB SEE PLAN #4 CONTINUOUS #4@12" #4@12" 10"2"EMBED PLATE 1/2"x8"x8" @ 4'-0" (2 MIN.) W/ (4) 1/2" DIA. x 6" HEADED STUDS (TYP. AT ELEVATOR SILL ANGLE) ELEVATOR SILL ANGLE COORDINATE WITH ELEVATOR SUPPLIER 3/163"TYP.1 1/2"5"TYP. 1 1/2" 5" WATER PROOFING - SEE ARCH 2#4 CONT. 3' - 0" EMBED FIBER REINF. CONCRETE 1'-0" NOTE: FOR REMAINDER OF SECTION NOT SHOWN SEE .1'-0"1'-0"SUMP PIT2"2" VERIFY SIZE W/ M.E.P. SUMP PIT - SEE PLAN #4@12" W/ STANDARD 90° HOOKS PROVIDE 1" GRATING COVER WHERE STATE BUILDING CODE SPECIFIES #4@12" E.W. 6/S2-03 1'-0" 2"2" T/PILE CAP #4@12" W/ STD. 90° HOOKS PILE CAP REINF. -SEE PLAN PROVIDE 1" GRATING COVER WHERE CODE REQUIRES #4@12" E.W. T/SLAB SEE PLAN EMBED PLATE 1/2"x8"x8" W/ (4) 1/2" DIA. x 6" HEADED STUDS3"TYP.1 1/2"5"TYP. 1 1/2" 5"2"HSS8x4 SEPARATOR BEAM W/ STD. HOLES#4@ 12" #4 CONTINUOUS3' - 0"1 1/2"3"1 1/2"1/2" 1 1/2" 2"1/4"CONNECTION DETAIL PC WT5x15 W/ STD. HOLES 3/4" DIA. BOLT (HAND TIGHTEN AND MAR THREAD OR TACK WELD) 3/8" PLATE W/ HORIZ. LONG SLOTS EMBED TYP. 1/4 3/16 FIBER REINF. CONCRETE 1" HSS HSS8x4x1/2 TYP. U.N.O. L6x4x3/8x1'-0" (LLH) W/ 3/4" DIA.x6" LG. STUDS AS SHOWN 4" 4"4" 4" HSS (CONTRACTOR TO COORD. LOCATIONS W/ ELEVATOR DRAWINGS) AT ELEVATOR PIT WALL ELEV. VERTICAL RAIL SUPPORT COLUMNS (2) HSS CONCRETE BEAM T/HSS 2-PL. 1/2"x6"x0'-6" W/ 13/16"x2" VERT. SLOT FOR 3/4" DIA. (A325) THRU BOLT (HAND TIGHTEN AND MAR THREAD OR TACK WELD) AT FLOOR SLAB PL. 1/2"x12"x1'-0" W/ 4-3/4" DIA. HEADED STUDS MIN. 6" EMBED 1" 5/16 3/4"CLR HSS (VERT. RAIL SUPPORTS, CONTRACTOR TO COORDINATE LOCATION W/ ELEVATOR DRAWINGS) HSS SEPARATOR BEAM (SEE PLAN) AT SEPARATOR BEAM HSS T/SLAB TYP. 1 1/2"5"TYP.1 1/2"5"3"2"8"10"3/16 ELEVATOR SILL ANGLE. COORDINATE W/ ELEVATOR SUPPLIER CONTINUOUS 2x4 KEY AND WATERSTOP 2#4 CONTINUOUS #4@12" CONT. EMBED PLATE 1/2"x8"x8" @2'-0" W/ 4-1/2" DIA.x6" HEADED STUDS (TYP. AT ELEVATOR SILL ANGLE) SEE MAT DETAILS FOR REINFORCING AND THICKNESS 3'-0"#4@12" #5@12" #4 CONT.FIBER REINF. CONCRETE ELEVATOR PIT - SEE FOUNDATION PLAN LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:30 PMS2−03 08.14.18TYPICAL FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL THICKENED SLAB AT CONCRETE STAIRS 2 TYPICAL THICKENED SLAB AT STAIR STRINGER 3 TYPICAL CONCRETE STAIR ON GRADE 4 TYPICAL CONCRETE STAIR ON GRADE 5 TYPICAL STAIR SUPPORT COLUMN 6 TYPICAL ELEVATOR PIT WALL 7 TYPICAL ELEVATOR SUMP PIT 8 TYPICAL ELEVATOR SUMP PIT AT PILE CAP 9 TYPICAL SEPARATOR BEAM CONNECTION 10 TYPICAL ELEVATOR RAIL SUPPORT DETAIL 11 TYPICAL ELEVATOR PIT WALL AT MATS Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LAP SPLICE6"LAP SPLICE4'-0"4'-0"6"5'-0"8'-6"2'-6"2'-6"2'-6"2'-6"1'-9"1'-9"8'-0 1/2"8'-6" 1'-9"2'-6"1'-9"2'-6"2'-6"2'-6"3'-6"3'-0 1/2"2'-3 1/2"8'-6"8'-6" 2'-6"1'-9"1'-9"2'-6"2'-6"1'-9"2'-6"1'-9"9'-11 1/2"9'-11 1/2" 2'-6"2'-5 3/4"2'-5 3/4"2'-6"2'-6"2'-5 3/4"2'-6"2'-5 3/4"8'-6"12'-0" 2'-6"1'-9"3'-6"2'-6"2'-6"1'-9"2'-6"3'-6"11'-1"12'-0" 2'-6"3'-0 1/2"1'-9"2'-6"2'-6"3'-0 1/2"2'-6"1'-9"1'-9"1'-9"11'-1"12'-0" 2'-6"3'-0 1/2"1'-9"2'-6"2'-6"3'-0 1/2"2'-6"1'-9"1'-9"1'-9"12'-0"12'-0" 2'-6"3'-6"3'-6"2'-6"2'-6"3'-6"2'-6"3'-6"5'-0"2'-6"2'-6"2'-6"2'-6" 5'-0" DOWELS TO MATCH COLUMN VERTICAL BARS. (SEE SCHEDULE) OR SHEAR WALL VERTICAL BARS (SEE SHEAR WALL ELEVATIONS) STEEL PILES PILE CAP-SEE PLAN 3" CLR.PROVIDE STD. 180 DEG. HOOKS, TYPICAL TOP BARS AS REQ'D, SEE PILE CAP DETAILS SEE PILE CAP DETAILSPILE CAP DEPTHTYPICAL PILE PILES WITH TENSION (UPLIFT) SHOWN ON PLANS AS 2'-6" TYP.4" TYP.#8 DOWEL SECTION A-A PILE4"4"#8 DOWEL TYP.STEEL PILE AWS D1.4-98, TYP.(1/2") (1/2") A A GRADE BEAM PILE CAP-SEE PLAN 6" POCKET 3" CLR.TOP BARS AS REQ'D, SEE PILE CAP DETAILS DOWELS TO MATCH COLUMN VERTICAL BARS. (SEE SCHEDULE) OR SHEAR WALL VERTICAL BARS (SEE SHEAR WALL ELEVATIONS) STEEL PILES PROVIDE STD. 180 DEG. HOOKS, TYPICALSEE PILE CAP DETAILSPILE CAP DEPTHSEE FOR DETAIL FOR PILES IN TENSION (UPLIFT)1/S2-11 COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN10#9 BOT., E.W. COLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN PILE CAP CENTROID & COLUMN CENTER, TYP UNLESS NOTED OTHERWISE ON PLAN 8#10 BOT., TYP. 3 WAYSCOLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN12#10 BOT., E.W.COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN15#10 BOT., E.W.COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN16#10 BOT., E.W.COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLANTYP, UNLESS NOTEDOTHERWISE ON PLAN23#10 BOT., E.W.COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN23#10 BOT., E.W.COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLAN TYP, UNLESS NOTEDOTHERWISE ON PLAN23#10 BOT., E.W. FIBER REINF. CONCRETE T/SLAB SEE PLAN COL. & FTG. SEE SCHEDULE FOR FOOTING SIZE AND REINFORCING 2" DIA. TEST HOLE SEE NOTES 1 & 2NOTES: 1. DEPTH OF TEST HOLE TO EQUAL 1.5 x LARGER FOOTING DIMENSION (MIN. 6 FEET, MAX. 10 FEET). 2. FOOTINGS GREATER THAN 5 FEET IN WIDTH REQUIRE TWO HOLES. T/FTG SEE PLAN STD 90 DEGREE HOOK T/SOUND ROCK TIES @ 6" IN FOOTING COLUMN COLUMN DOWELS - COORDINATE WITH COLUMN SCHEDULE SOUND ROCK UNREINFORCED CONCRETE FILL (f 'c = 3,000 psi MIN.) FOOTING TEST HOLE SEE SECTION FOR ADDITIONAL INFORMATION H/2H/2 (8'-0" MAX.)H12/S2-11 COLUMN & PILE CAPCOLUMN & PILE CAP TYP, UNLESS NOTED OTHERWISE ON PLANTYP, UNLESS NOTEDOTHERWISE ON PLAN8#9 BOT., E.W.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:36 PMS2−11 08.14.18TYPICAL FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SECTION AT TYPICAL PILE CAP 2 SECTION AT TYPICAL PILE CAP / GRADE BEAM 4 PILE CAP TYPE "PC2" DEPTH = 4'-4" 5 PILE CAP TYPE "PC3" DEPTH = 4'-4" 6 PILE CAP TYPE "PC4" DEPTH = 4'-4" 7 PILE CAP TYPE "PC5" DEPTH = 4'-4" 8 PILE CAP TYPE "PC6" DEPTH = 5'-6" 9 PILE CAP TYPE "PC7" DEPTH = 5'-6" 10 PILE CAP TYPE "PC8" DEPTH = 5'-6" 11 PILE CAP TYPE "PC9" DEPTH = 6'-0" 12 TYPICAL COLUMN FOOTING DETAIL 13 TYP. SECTION AT FOOTING ON ROCK BEARING ELEV. BELOW BOTTOM OF FOOTING 3 PILE CAP TYPE "PC1" DEPTH = 4'-4" FOOTING SCHEDULE MARK LENGTH WIDTH THICKNESS BOTTOM REINFORCEMENT LONG WAY SHORT WAY F4 4'-0" 4'-0" 1'-0" 7#4 7#4 F7 7'-0" 7'-0" 4'-0" 8#9 8#9 14 FOOTING SCHEDULE Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 4 5 5 3.9 5.7 5.7 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 SW-2ASW-3ASW-4A SW-5A SW-6A2'-6"5'-9"5'-9"4'-6"4'-6"4'-6"4'-6"2'-6"2'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 4'-6" 2'-6" 25'-0"21'-10"19'-10"6"21'-5"2'-3"2'-3"WALL2'-3"2'-3"WALLWALL 2'-6" 2 LAYERS #9@12"T 2 LAYERS #9@6"B 2 LAYERS #9@12"T2 LAYERS #9@6"B2 LAYERS #9@12"T 2 LAYERS #9@6"B2 LAYERS #9@12"T2 LAYERS #9@6"B2'-6"4'-6"4'-6"4'-6"4'-6"5'-9"D.2 C.1 D.1 2.8 2.8 B.8B.8 D.4 D.4 C.8C.8 C.9C.9 SW-1A2.3 11'-0"8'-10"6"15'-8"5'-9"2'-6" 4'-6" 4'-6" 4'-6" 4'-6" 2'-6" WALL 2'-0"4'-6"4'-6"4'-6"4'-9"4'-9"4'-9"4'-9"4'-9"4'-6"4'-6"4'-6"3'-0"2'-3" 2'-3"#9@12"T2 LAYERS #9@6"B#9@12"T 2 LAYERS #9@6"B #9@12"T 2 LAYERS #9@12"B #9@12"T 2 LAYERS #9@6"B D.2 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:40 PMS2−12 08.14.18FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851PILE CAP TYPE "PC118" PILE CAP DEPTH = 84"2 PILE CAP TYPE "PC48" PILE CAP DEPTH = 84" Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 8" 8" 1'-6" FINISHED GRADE OR T/SLAB- SEE ARCH. DRAWINGS 5#4 CONTINUOUS #5@12"8"T/SLAB SEE PLAN 2x4 KEY #4@12" #4@12" #4 CONTINUOUSC8x11.5 CONTINUOUS WITH 1/2''Ø x 6'' HEADED STUDS @ 2'-0'' (STAGGERED)60° GRANULAR BACKFILL FIBER REINF. CONCRETE 1'-0"1'-0" MIN.4'-0" MAX.ELEVATOR PIT ELEVATOR PIT ELEVATOR PITT/SLAB SEE PLAN 7'-1"5'-4"9'-3"T/SLAB SEE PLAN T/FND. 703'-11" SHEARWALL- SEE PLAN SHEARWALL- SEE PLAN RAISED SLAB ON POLYSTYRENE FILL -SEE 1/S3-01 RAISED SLAB ON POLYSTYRENE FILL - T/SLAB SEE PLAN 3'-6"T/FND #6@12" 10#6 CONT. T&B 3" CLR.2'-6"4'-0"2'-6" BOND BREAKER SEE 16/S2-01 12"CONCRETE SLAB 4" 1'-4" SEE 16/S2-01 #8@9" #4@12" CONT. #4@12"2'-0"6'-0"#8@9" #4@12" #4@9" T/SLAB SEE PLAN 3'-0" SEE 3/S2-01 FOR DETAILS NOT SHOWN 1 1/2" CLR. 8" #4@10" #4@8" CONT. T/SLAB VARIES T/SLAB VARIES T/SLAB SEE PLAN T/SLAB VARIES #4@10" #4@8" CONT. 2#4 CONT.6"6" 1'-0" 12" CMU WALL T/WALL SEE ARCH SEE 3/S2-01 CONTINUOUS 2x4 KEY AND WATERSTOP T/SLAB VARIES SEE 16/S2-01 SEE ARCH.2'-9" MIN.1 1/2" CLR #4@8" CONT. #4@8" T/FTG SEE PLAN CONTINUOUS 2x4 KEY AND WATERSTOP 3'-4" 8" 1'-0"2'-0"#5@12" 18#7 CONT. SEE 16/S2-01 T/SLAB SEE PLAN T/FTG SEE PLAN T/SLAB VARIES SEE 16/S2-01 #4@8" CONT. #4@10" 12" CMU WALL CONTINUOUS 2x4 KEY AND WATERSTOP 3'-0" 1'-0" 1'-0"2'-0"2'-9" MIN.SEE 16/S2-01 T/SLAB SEE PLAN 2'-0"#5@12" 18#7 CONT.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:43 PMS2−21 08.14.18FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2 TYPICAL SECTION AT LOADING DOCK 1 SECTION5SECTION 3 SECTION 4 SECTION 6 SECTION 7 SECTION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 PILE CAP - SEE PLAN ELEVATOR SHAFT SEE 6/S2-03 FOR ELEVATOR PIT INFORMATION #4@12" E.F. #4 CONT. E.F. LEVEL 1 SEE PLAN 8 1/2" 8"#4@12" CONT. #4@12" SEE 16/S2-01 T/SLAB SEE PLAN STONE VENEER - SEE ARCH. T/LEDGE SEE ARCH.6'-0" MAX.HANDRAIL - SEE ARCH.1'-0"1'-0" 4" 8" 2'-6" #5@12" #4@12" CONT. CONTINUOUS 2x4 KEY AND WATERSTOP #4@12"#5@12" 6#4 CONT. FINISHED GRADE - SEE CIVIL T/FTG SEE PLANAND CIVILCOORD. W/ ARCHSEE 16/S2-01 T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL 1'-0"3'-2" 1'-4" 1'-0" FACADE - SEE ARCH.AND CIVILCOORD. W/ ARCH7'-0" MAX.T/LEDGE SEE ARCH. T/FTG SEE PLAN 8" 8" #5@9" #4@12" CONT. CONTINUOUS 2x4 KEY AND WATERSTOP #4@12" #5@12" 9#4 CONT. EQ EQ T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL SEE 19/S2-01 FOR TRENCH DRAIN DETAIL CONCRETE CURB - SEE 4/S2-01 PLANSEET/CURB SEE ARCH. 8" FACADE - SEE ARCH. SEE 16/S2-01 T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL CONCRETE WALL - FOR REINF. SEE 8/S3-52 7'-6" MAX.1'-0" 3'-0"2'-0"6" 6" 6"1'-0"T/FTG SEE PLAN #5@12" #4@12" CONT. CONTINUOUS 2x4 KEY AND WATERSTOP LAP SPLICECLASS "B" TENSIONLAP SPLICECLASS "B" TENSION#5@12" #5@12" 16#7 CONT. SEE 16/S2-01 T/SLAB SEE PLAN 1'-0"FINISHED GRADE - SEE CIVIL CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT.2'-0"6'-0" MAX.AND CIVILCOORD. W/ ARCH.T/FTG SEE PLAN #5@12" #4@12" CONT. #5@12" 1'-0" 3'-0"LAP SPLICECLASS "B" TENSIONSEE 16/S2-01 T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT. T/FTG SEE PLAN #5@12" #4@12" CONT. #5@12"LAP SPLICECLASS "B" TENSIONAND CIVILCOORD. W/ ARCH.7'-0" MAX.2'-0"1'-0" 3'-0" 12" CMU WALL SEE 16/S2-01 T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT. T/FTG SEE PLAN #5@12" #4@12" CONT. #5@12"2'-0"6'-0" MAX.AND CIVILCOORD. W/ ARCH.GUARDRAIL - SEE ARCH. 1'-0" 3'-0"1'-0"LAP SPLICECLASS "B" TENSIONLLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:47 PMS2−22 08.14.18FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SECTION Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 2 SECTION4SECTION 3 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION 08/14/18 SEE 16/S2-01 T/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT. T/FTG SEE PLAN #5@12" #4@12" CONT. #5@12"2'-0"6'-0" MAX.GUARDRAIL - SEE ARCH. 1'-6" 1'-0" 1'-6"AND CIVILCOORD. W/ ARCH.1'-0"LAP SPLICECLASS "B" TENSIONT/SLAB SEE PLAN FINISHED GRADE - SEE CIVIL SEE 16/S2-01 CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT. #5@12" #4@12" CONT. #5@12" 1'-0" 3'-0"LAP SPLICECLASS "B" TENSION12" CMU WALL 2'-0"6'-6" MAX.AND CIVILCOORD. W/ ARCH.T/FTG SEE PLAN FINISHED GRADE - SEE CIVIL SEE 16/S2-01 T/SLAB SEE PLAN 1'-0"CONTINUOUS 2x4 KEY AND WATERSTOP #5@12" 16#7 CONT. T/FTG SEE PLAN #5@12" #4@12" CONT.LAP SPLICECLASS "B" TENSION2'-0"10'-0" MAX.AND CIVILCOORD. W/ ARCH.1'-6" 1'-0" 1'-6" DETENTION VAULT T/SLAB SEE PLAN PREFORMED JOINT FILLER 3#4CONT. 8" VAULT SLAB - SEE PLAN FOR SLAB REINF. 1'-0"6'-0" MAX.4"1'-3"SEE PLANT/FTG SEE CIVIL #4@12" E.F. #4@9" E.F.PLANSEE1'-8"#4@12" U-BAR #7@12 E.W. T&B 3'-6"T/FND #6@12" 10#6 CONT. T&B 3" CLR.2'-6"4'-0"2'-6" SEE 16/S2-01 #8@9" #4@12" T/SLAB SEE PLAN 8" 4" 1'-4" 3'-0" 1 1/2" CLR #4@8" #4@8" 8"2'-9" MIN.T/SLAB VARIES #8@9" #4@12" CONT. #4@12" T/SLAB SEE PLAN SEE 16/S2-01 T/FTG SEE PLAN T/SLAB SEE PLAN #5@12" #4@12" CONT. CONTINUOUS 2x4 KEY AND WATERSTOP 2'-10" 8" 1'-0"2'-0"5'-0" MAX.#5@12" 18#7 CONT.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:50 PMS2−23 08.14.18FOUNDATION SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION AT DETENTION VAULT 5 SECTION6SECTION 08/14/18 18" MAX.SEEPLANSEE ARCH.15" MAX.SEEPLAN18" MAX.SEEPLANSEE ARCH.15" MAX.SEEPLANEXTRUDED POLYSTYRENE BOARD FILLER (SEE STRUCTURAL NOTES) CONCRETE WALL PLAN DETAIL AT RAISED SLAB EXTRUDED POLYSTYRENE BOARD FILLER (SEE STRUCTURAL NOTES) RAISED SLAB THICKNESS IS GREATER THAN 6" TOPPING SLAB THICKNESS LESS THAN OR EQUAL TO 6" FIBER TYPE "B" REINF. CONCRETE #4 @18" AT EDGE RIBS #4@18" AT EDGE WALLS 6" APPLY BONDING AGENT AT TOP OF STRUCTURE/SLAB FIBER REINF. CONCRETE T ≤ 6"T > 6"4"6" TYP. 8'-0"TYP. 6"TYP.6"TYP.4'-0"6" 4'-0" 6" 4'-0" 6" APPLY BONDING AGENT AT TOP OF STRUCTURE/SLAB NOTES: 1. TOPPING SLABS SHALL BE LIGHTWEIGHT STRUCTURAL CONCRETE. 2. PROVIDE CONTRACTION JOINTS SIMILAR TO SLAB ON GRADE CONTRACTION JOINTS FOR LARGE TOPPING SLAB AREAS NOTE: 1. SINGLE CONDUIT OUTSIDE DIAMETER (O.D.) SHALL NOT EXCEED 1/4 THE SLAB THICKNESS. 2. THE COMBINED HEIGHT OF CROSSING CONDUITS SHALL NOT EXCEED 1/3 THE SLAB THICKNESS. 3. MINIMUM SPACING OF CONDUITS IS 3xO.D. 4. REINFORCE JUCTION BOXES AS SLAB OPENINGS. 5. ADDITIONAL REINFORCEMENT SHOWN IN DETAIL REQUIRED AT GROUPS OF 3 OR MORE CONDUITS. 6. SEE STRUCTURAL NOTES FOR CLEAR COVER, T&B.PLANSEESEE NOTE 6ADD #3@12"x3'-0" (MIN.) EXTEND 12" PAST EACH SIDE OF CONDUIT TOP OR BOTTOM (WHICHEVER FACE CONDUIT IS CLOSEST) CONDUIT T/SLAB SEE PLAN L2-1/2x2-1/2x1/4 W/ 1/2" DIA.x5" HEADED STUDS @ 12" M.P.E. SUPPORT NOTE: INSTALL EMBEDS AS REQUIRED FOR EQUIPMENT ATTACHMENT, U.N.O NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR THE STRUCTURAL DESIGN OF HANDRAILS AND THEIR ATTACHMENT TO THE STRUCTURE. CONTRACTOR ALSO RESPONSIBLE FOR SEALING THE INTERIOR OF HOLLOW HANDRAIL POST AGAINST WATER INTRUSION. 2. SEE ARCHITECTURAL DRAWINGS FOR HANDRAIL DESIGN. 3. 5 1/2" MIN. - SEE ARCHITECTURAL DRAWINGS. 4. PLACE 1#4 CONT. AND #3 HAIRPINS FLUSH WITH INSIDE OF SLAB ROTATED HOOK BAR. IF NO HOOK, PROVIDE 1 1/2" CLEAR. 5. IF PT ANCHOR @ EDGE, TRANSITION #4 BETWEEN #3 HAIRPINS @ HANDRAIL POST BLOCKOUT PER SECTION A. 6. #3 HAIRPIN SHALL BE TYPICAL BAR BEND TYPE 17 PER CRSI MANUAL OF STANDARD PRACTICE. 7. MAINTAIN 1 1/2" REBAR COVER IN CORNER @ HAIRPIN OVERLAP. 8. REFER TO STRUCTURAL NOTES SHEET AND SPECIFICATIONS FOR REQ'D COVER OF SLAB REBAR. REFER TO PLANS FOR REQ'D TOP & BOTTOM REBAR. 9. IF BOTTOM TEMP. REBAR REQ'D ON PLANS, PLACE ONE OF THESE BARS TOP @ 1 1/2" CLEAR OF HANDRAIL BLOCKOUT. OTHERWISE, PLACE ONE TOP TEMP. BAR @ THIS LOCATION. 10. ALUMINUM POSTS GOUTED INTO CONCRETE SHALL BE COATED TO PREVENT ELECTROLYTIC, GALVANIC, OR OTHER REACTIONS. UNLESS SPECIFIED BY THE ARCHITECT OR SUPPLIER, EMBEDDED PORTIONS SHALL BE PROTECTED BY A BITUMINOUS OR ASPHALT-BASED PAINT OR COATING. BLOCKOUT & EDGE OF SLAB 4" MIN. BETWEEN EDGE OF AT EDGE TERMINATE 2#4 PT BACKER BARS 1 1/2" CLR. FROM BLOCKOUT (IF APPLICABLE). PLACE BARS BETWEEN #3 HAIRPINS. EDGE OF SLAB 1#4 CONT. NOTE 4 A B #3 HAIRPIN T&B (NOTE 6) HANDRAIL POST 1' - 9" 8" TYP. SLAB TOP HK. BAR POST BLOCKOUT SIZE BY HANDRAIL DESIGNER (CONTRACTOR TO COORD. W/ ARCHITECT). CENTER BLOCKOUT 6" MIN. FROM SLAB EDGE, TYP. IF BLOCKOUT IS GREATER THAN 4" DIA. OR 4"x4", CONTACT E.O.R. AT CORNER EDGE OF SLAB A B HANDRAIL POST TYP. SLAB TOP HK. BAR OVERLAPPING HAIRPINS (NOTE 7) #3 HAIRPIN T&B (NOTE 6)CLR.1 1/2"CLR.1 1/2"NOTE 3MAX.1/2"BLOCKOUT1 1/2" BOT. OF CLR. 1 1/2" SLAB TEMP. BARS (NOTE 9) DRIP BEAD COORD. W/ ARCH. 1#4 CONT. #3 HAIRPIN T&B SECTION A SLAB TEMP. BARS (NOTE 9) ROTATE SLAB HOOK AS REQ'D TO MAINTAIN 1 1/2" MIN. SOFFIT CLEAR COVER. SECTION B NOTE 8 TO DRIP BEAD) 1 1/2" CLR. (BOT. BAR NOTE 8NOTE 81#4 CONT. (NOTE 5) 2#4 PT BACKER BARS. SIM. SIM. 1 1 6"1"2#4 (CENTERED ON CORNER) SEE NOTE 1 AND NOTE 2 3'-6". 6" 1 1 2#4x3'-0" (CENTER ON CORNER) SEE NOTE 1 NOTES: 1. INSTALL BELOW UPPER LAYER OF SLAB REINFORCING. 2. DOES NOT APPLY TO BALCONY CORNERS. 6" NOTE: 1. NO SLAB PENETRATIONS EXCEEDING 4" SHALL BE PLACED WITHIN 2'-0" OF COLUMNS WITHOUT PRIOR APPROVAL OF THE ENGINEER. 2. SLAB PENETRATIONS SHOULD BE AVOIDED ALONG LINES OF CONCENTRATED (BANDED) POST- TENSIONED TENDONS. 3. NO SLAB PENETRATIONS LARGER THAN INDICATED HERE SHALL BE PERMITTED WITHOUT PRIOR APPROVAL OF THE ENGINEER. 2#4 x 4'-0" DOWELS - TYP. ALL FOUR SIDES OF BLOCKOUT. 2"MAX. 1'-0"2" TEMPORARY BLOCKOUT NOTES: 1. WHERE CLEAR SPACING "A" BETWEEN ADJACENT SLEEVES IS LESS THAN 3", THE SLEEVE GROUP SHALL BE TREATED AS AN EQUIVALENT RECTANGULAR OPENING WITH LENGTH "L" AND WIDTH "W" AS SHOWN. 2. WHERE CLEAR SPACING BETWEEN ADJACENT SLEEVES IS GREATER THAN OR EQUAL TO 3", SCHEDULED SLAB BAR REINFORCEMENT SHALL BE OFFSET AS REQUIRED TO MISS SLEEVES. 3. REINFORCEMENT SHOWN IS ADDITIONAL TO SCHEDULED SLAB REINFORCEMENT. 4. SCHEDULED SLAB MESH REINFORCEMENT MAY BE CUT AS REQUIRED TO MISS PIPE SLEEVES. 5. REFER TO MECHANICAL DRAWINGS FOR LOCATION AND SIZE OF SLEEVES. 6. ISOLATED PIPE SLEEVES THAT ARE SMALLER THAN 5" AND DO NOT INTERRUPT REINFORCING DO NOT REQUIRE THE USE OF THIS DETAIL. 7. THIS DETAIL SHOULD NOT BE USED FOR OPENING GROUPS WITH DIAMETERS LARGER THAN 12". CONSULT ENGINEER FOR FRAMING OF SUCH CONDITIONS. A2'-0"2'-0" A "L""W"TYP.2"2' - 0" MIN.Ld + W/22' - 0" MIN. Ld + W/2 PLAN VIEW FOR A ≥ 3" PLAN VIEW FOR A < 3" EQUIVALENT RECTANGULAR OPENING PROVIDE 1/2 OF INTERRUPTED REINFORCEMENT PLUS ONE ADDL. BAR OF SAME SIZE AS INTERRUPTED REINFORCEMENT ON EACH SIDE OF EQUIVALENT RECTANGULAR OPENING. PROVIDE MINIMUM (1) #4 TOP AND BOTTOM EACH SIDE OF OPENING. (1) #4 TOP & BOTTOM (TYP.) (1) #4 TOP & BOTTOM2" TYPICAL6" 6" WINDOW WASHING TIE-BACK (BY OTHERS) COORDINATE ATTACHMENT WITH MANUFACTURER REQUIREMENTS EMBED PLATE 1"x18"x1'-6" W/ 9-3/4" DIA.x3 3/8" HEADED STUDS ADDITIONAL 4#4x8'-0"@6" E.W. TOP & BOTTOM CENTERED ABOUT TIE-BACK 6" 6" EMBED PLATE 1"x18"x1'-6" W/ 9-3/4" DIA.x3 3/8" HEADED STUDS ADDITIONAL 4#4x8'-0"@6" E.W. TOP & BOTTOM CENTERED ABOUT TIE-BACK 3"PLATE 3/4"x8"x8" HSS6.625x0.280 5/16 5/16 1 1/4" PLATE 5000 LB WORKING LOAD (MAX.)R 3 "R 2 " TIE-BACK ANCHOR NOTES 1. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED. 2. ALL PLATE CORNERS SHALL BE GROUND SMOOTH. 3. SEE ARCH DWGS. FOR LOCATIONS. TYP. 2" WINDOW WASHING TIE-BACK (BY OTHERS) COORDINATE ATTACHMENT WITH MANUFACTURER REQUIREMENTS EMBED PLATE 1"x12"x1'-0" W/ 4-3/4" DIA.x6" HEADED STUDS ADDL 4#4 CLOSED TIES @6" CENTERED ABOUT TIE-BACK 3"PLATE 3/4"x8"x8" HSS6.625x0.280 5/16 5/16 1 1/4" PLATE 5000 LB WORKING LOAD (MAX.)R 3 "R 2 " TIE-BACK ANCHOR NOTES 1. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED. 2. ALL PLATE CORNERS SHALL BE GROUND SMOOTH. 3. SEE ARCH. DWGS. FOR LOCATIONS. ADDL 4#4 CLOSED TIES @6" CENTERED ABOUT TIE-BACK EMBED PLATE 1"x12"x1'-0" W/ 4-3/4" DIA.x6" HEADED STUDS TYP. 2"LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:54 PMS3−01 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL CONCRETE TOPPING/RAISED SLAB DETAILS 2 TYPICAL SECTION AT CONDUIT IN ELEVATED SLAB 3 TYPICAL EMBED DETAIL AT MECHANICAL OPENINGS 4 TYPICAL DETAIL AT HANDRAIL POST BLOCKOUT 5 TYPICAL ADDITIONAL SLAB CORNER REINFORCING 6 TYPICAL DETAIL AT MEP BLOCKOUTS 8 TYPICAL DETAIL AT PIPE SLEEVES 7 NOT USED 9 TYPICAL ROOF TIE-BACK (TIE-BACK NOT BY SDL) 10 TYPICAL ROOF TIE-BACK (ALTERNATE TO 9/S3-01) 11 TYPICAL ROOF TIE-BACK (TIE-BACK NOT BY SDL) 12 TYPICAL ROOF TIE-BACK (ALTERNATE TO 11/S3-01) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 2"3'1/4"1/2"1 1/2"2"1 1/2"1 1/2"3'1/4"T/SLAB STAIR STRINGER (BY STAIR SUPPLIER) SEE ARCH. DRAWINGS STAIR LANDING (BY STAIR SUPPLIER) L5x3x3/8 (LLV) WASHER & NUT - MAR THREADS OR TACK WELD NUT THREADS AT END OF HANGER PLATE 3/8"x7"x7" PLATE 1/2"x8"x8" W/ 4-3/4" DIA.x6" HEADED STUDS 1"6"1"1" 4" 3" EMBED 8"8" FACE OF CONCRETE 3/16 6 6 T/SLAB EMBED 1 1/2"5 1/2"5 1/2"1 1/2"4"1'-2" B/BEAM 1/2"x7"x1'-2" EMBED PLATE W/ 3-3/4" DIAx 6" HEADED STUDS ROD TO STRINGER CONNECTION BY STAIR SUPPLIER HANGER ROD BY STAIR SUPPLIER (COORD LOCATION WITH ARCH) STAIR STRINGER (BY STAIR SUPPLIER) SEE ARCH. DRAWINGS STAIR LANDING (BY STAIR SUPPLIER) ARCH SEE4"HANGER ROD TO EMBED CONNECTION BY STAIR SUPPLIER (COORD EDGE OFF CONNECTION W/ ARCH) CENTER ROD ON EMBED PLATE HANGER ROD BY STAIR SUPPLIER (COORD LOCATION WITH ARCH) NOTES: 1. IF WALL IS 8" CMU THEN ELIMINATE ROD HANGER AND USE CMU TO SUPPORT METAL STAIR. T/SLAB STAIR STRINGER (BY STAIR SUPPLIER) SEE ARCH. DRAWINGS STAIR LANDING (BY STAIR SUPPLIER) L5x3x3/8 (LLV) WASHER & NUT - MAR THREADS OR TACK WELD NUT THREADS AT END OF HANGER PLATE 3/8"x7"x7" PLATE 1/2"x8"x8" W/ 4-3/4" DIA.x6" HEADED STUDS 1"6"1"1" 4" 3" EMBED 8"8" FACE OF CONCRETE 3/16 6 6 T/SLAB EMBED 1 1/2"5 1/2"5 1/2"1 1/2"4"1'-2" B/BEAM 1/2"x7"x1'-2" EMBED PLATE W/ 3-3/4" DIAx 6" HEADED STUDS ROD TO STRINGER CONNECTION BY STAIR SUPPLIER HANGER ROD BY STAIR SUPPLIER (COORD LOCATION WITH ARCH) STAIR STRINGER (BY STAIR SUPPLIER) SEE ARCH. DRAWINGS STAIR LANDING (BY STAIR SUPPLIER) ARCH SEE4"HANGER ROD TO EMBED CONNECTION BY STAIR SUPPLIER (COORD EDGE OFF CONNECTION W/ ARCH) CENTER ROD ON EMBED PLATE HANGER ROD BY STAIR SUPPLIER (COORD LOCATION WITH ARCH) NOTES: 1. IF WALL IS 8" CMU THEN ELIMINATE ROD HANGER AND USE CMU TO SUPPORT METAL STAIR. STAIR STRINGER (BY STAIR SUPPLIER) SEE ARCH.1 1/2"L4x3x1/4xCONT. (LLV) W/ 1/2" DIA.x6" HEADED STUDS @ 24" EMBED PLATE 1/2"x12"x12" W/ (4) 3/4" DIA. x6" LONG HEADED STUDS @ 4" E.W. 5/16 SEE PLAN NOTE: FOR LANDING COLUMN LOCATIONS - SEE ARCH. STAIR STRINGER (BY STAIR SUPPLIER)T/SLAB EMBED PLATE 3/4"x8"x0'-8" w/ 4 - 3/4"x4" HEADED STUDS STAIR STRINGER (BY STAIR SUPPLIER) SECTION - A SEE ARCH. PLAN A ∠4x4x1/4x0'-6" AND ANGLE LEG EMBED PLATE 1/4 TYP. 1 1/2"5"5"TYP.1 1/2"3/16 EMBED PLATE 1/2"x8"x8" @2'-0" W/ 4-1/2" DIA.x6" HEADED STUDS ELEVATOR SILL ANGLE. COORDINATE W/ ELEVATOR SUPPLIER2"MIN.3"TYP. 1 1/2"5"3"5"TYP.1 1/2"3/16 EMBED PLATE 1/2"x8"x8" @2'-0" W/ 4-1/2" DIA.x6" HEADED STUDS ELEVATOR SILL ANGLE. COORDINATE W/ ELEVATOR SUPPLIER2"MIN.3"ARCH. FINISHED FLOOR 2#4x3'-0" CENTERED ON EMBED PLATE HSS8x4 SEPARATOR BEAM W/ STD. HOLES T/SLAB ARCH. FINISHED FLOOR EMBED PLATE 1/2"x8" W/ 4-1/2" DIA.x6" HEADED STUDS TYP. 1 1/2"5"5"TYP.1 1/2"SEE DETAIL A 1/2" 1 1/2"1 1/2"1 1/2"1/4"3/8" PL. W/ HORIZ. LONG SLOTS 3/4" DIA. BOLT (HAND TIGHTEN AND MAR THREAD OR TACK WELD) PC WT5x15 W/ STD. HOLES 3/16 TYP. 3/16 DETAIL A HSS8x4 SEPARATOR BEAM W/ STD. HOLES T/SLAB ARCH. FINISHED FLOOR EMBED PLATE 1/2"x8" W/ 4-1/2" DIA.x6" HEADED STUDS TYP. 1 1/2"5"5"TYP.1 1/2"SEE DETAIL A 1/2" 1 1/2"1 1/2"1 1/2"1/4"3/8" PL. W/ HORIZ. LONG SLOTS 3/4" DIA. BOLT (HAND TIGHTEN AND MAR THREAD OR TACK WELD) PC WT5x15 W/ STD. HOLES 3/16 TYP. 3/16 DETAIL A 4"5"TYP.1 1/2"2"T/SLAB EMBEDDED PLATE - 3/8"x8"x0'-8" W/ 4-3/4"x4" HEADED STUDS FACE OF CONC. SLAB STAIR STRINGER (BY STAIR SUPPLIER) T/SLAB EMBEDDED PLATE - 3/8"x8"x0'-8" W/ 4-3/4"x4" HEADED STUDS 1" 1"LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:13:57 PMS3−02 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL STAIR HANGER DETAIL FOR STAIRS LESS THAN 10'-0" WIDE 2 TYPICAL STAIR HANGER DETAIL FOR STAIRS LESS THAN 10'-0" WIDE 3 TYPICAL STAIR STRINGER ATTACHMENT 5 TYPICAL STAIR SUPPORT COLUMN 6 TYPICAL STAIR STRINGER ATTACHMENT AT ELEVATED POST - TENSIONED SLAB 7 TYPICAL SECTION AT ELEVATOR SILL 8 TYPICAL SECTION AT ELEVATOR SILL 9 TYPICAL SEPARATOR BEAM CONNECTION 10 TYPICAL SEPARATOR BEAM CONNECTION 4 TYPICAL STAIR STRINGER ATTACHMENT Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 T2" CLEAR FOR BUNDLES OF 4 OR MORE TENDONS - SEE DETAIL FOR BANDED TENDONS 2#4 CONTINUOUS (MIN.) TENDON ANCHOR. IF T<7", TURN HORIZONTAL TFOR BUNDLES OF 4 OR MORE TENDONS - SEE DETAIL FOR BANDED TENDONS TENDON ANCHOR. IF T<7", TURN HORIZONTAL 2#4 CONTINUOUS (MIN.) POCKET FORMER CUT OFF EXCESS TENDON AND DRY PACK POCKET AFTER STRESSING T2" CLEAR STRESS A MINIMUM OF 2 TENDONS AT THE SLAB EDGE PERPENDICULAR TO THE BANDED TENDONS BEFORE THE BANDED TENDONS ARE STRESSED TENDON ANCHOR. IF T<7", TURN HORIZONTAL T/2 1'-2" 2#4 CONTINUOUS (MIN.) #3 HAIRPINS AT BANDED TENDONS (TOTAL EQUAL TO NUMBER OF ANCHORS PLUS ONE) SEE DETAIL FOR SPACING TSTRESS A MINIMUM OF 2 TENDONS AT THE SLAB EDGE PERPENDICULAR TO THE BANDED TENDONS BEFORE THE BANDED TENDONS ARE STRESSED T/2 1'-2"#3 HAIRPINS AT BANDED TENDONS (TOTAL EQUAL TO NUMBER OF ANCHORS PLUS ONE) POCKET FORMER CUT OFF EXCESS TENDON AND DRY PACK POCKET AFTER STRESSING TENDON ANCHOR. IF T<7", TURN HORIZONTAL 2#4 CONTINUOUS (MIN.)PLAN"T" SEESLAB REINFORCING SEE PLAN UNIFORM TENDONS (2 MIN. AT COLUMNS) 1.5T BANDED TENDONS 1.5T * 1/2" MAX. PENETRATION OF COLUMN INTO SLAB*SLAB REINFORCING SEE PLAN *PLAN"T" SEESLAB REINFORCING SEE PLAN BANDED TENDONS STANDARD ACI 180° HOOK 1.5T UNIFORM TENDONS * 1/2" MAX. PENETRATION OF COLUMN INTO SLAB*SLAB REINFORCING SEE PLAN * EXTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT EXTERIOR SPAN INTERIOR SPAN CANTILEVER SPAN CLR. 2" 6"L1 1/3 L1 1/6 L1 ℓ1 ℓ2 ℓ3 GREATER 1/6 L1 OR 1/6 L2 GREATER 1/6 L1 OR 1/6 L2 GREATER 1/6 L2 OR 1/6 L3 1/4 L2 1/2 L2 1/4 L2 L2 L3 STD ACI 180° HOOK POINT 0.1 ℓ1 INFLECTION POINT 0.1 ℓ2 INFLECTION POINT 0.1 ℓ1 INFLECTION POINT 0.1 ℓ3 INFLECTION POINT 0.1 ℓ2 INFLECTION NOTES: 1. 3/4" CLEAR TYPICAL UNLESS NOTED OTHERWISE ON DRAWINGS. 2. 3/4" CLEAR UNLESS NOTED OTHERWISE ON DRAWING. 1" CLEAR AT PARKING AREAS AND AREAS EXPOSED TO WEATHER. 3. BOTTOM BARS ARE REQUIRED ONLY IF SHOWN ON PLANS. 4. BAR LENGTHS GIVEN ARE MINIMUM UNLESS OTHERWISE SHOWN ON PLANS.NOTE 1NOTE 1NOTE 2NOTE 1NOTE 1SEE PLAN"T"SLAB THICKNESST/2T/2NOTE 2NOTE 2LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:01 PMS3−11 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL NON-STRESSING END DETAIL AT UNIFORM TENDONS 2 TYPICAL STRESSING END DETAIL AT UNIFORM TENDONS 4 TYPICAL NON-STRESSING END DETAIL AT BANDED TENDONS 5 TYPICAL STRESSING END DETAIL AT BANDED TENDONS 6 TYPICAL DETAIL AT INTERIOR COLUMN 7 TYPICAL DETAIL AT EXTERIOR COLUMN 3 TYPICAL TWO WAY P.T. SLAB REINFORCING DIAGRAM Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 SEE SCHEDULE NOTES: 1. MAXIMUM SLEEVE SIZE IS 4" DIA. (NOMINAL) IN ANCHORAGE ZONE. 2. SCHEDULE 40 PIPE SLEEVES SHALL BE GALVANIZED WHEN USED IN SLABS EXPOSED TO WEATHER. 3. IF HANDRAIL POST BLOCKOUT INTERRUPTS PT BACKER BARS, TERMINATE END OF BARS 1 1/2" CLEAR EA. SIDE OF BLOCKOUT. MIN. 8"1'-6"1'-6"45°1'-6"MIN.6"PENETRATION IN ANCHORAGE ZONE MUST USE SCHEDULE 40 PIPE SLEEVE. PENETRATION EDGE FORM HANDRAIL POST TYP. HANDRAIL POST BLOCKOUT T#5x5'-0" T&B ADD'L AT EVERY ANCHOR 2'-6" T/2 1'-2" 2#4 CONTINUOUS (NOTE 2) #3 HAIRPINS - TOTAL EQUAL TO NUMBER OF ANCHORS PLUS ONE (SEE NOTES)T/2T/2NOTES: 1. HAIRPINS NOT REQUIRED WHERE CLEAR SPACING BETWEEN ANCHOR BUNDLES IS GREATER THAN 12 INCHES O.C. AND BUNDLES THAT HAVE 4 OR LESS TENDONS 2. IF HAIRPINS NOT REQUIRED, PLACE BARS BETWEEN ANCHOR FACE AND T/2 FROM ANCHOR FACE. 3. IF T<7", TURN TENDON ANCHORS HORIZONTAL.T2#4 CONTINUOUS (NOTE 2) #3 HAIRPINS - TOTAL EQUAL TO NUMBER OF ANCHORS PLUS 1 (SEE NOTES)T/2T/2NOTES: 1. HAIRPINS NOT REQUIRED WHERE CLEAR SPACING BETWEEN ANCHOR BUNDLES IS GREATER THAN 12 INCHES O.C. AND BUNDLES THAT HAVE 4 OR LESS TENDONS. 2. IF HAIRPINS NOT REQUIRED, PLACE BARS BETWEEN ANCHOR FACE AND T/2 FROM ANCHOR FACE. 3. ADD 1 1/2" DEEP x 0'-6" LONG KEYWAYS 2'-0" O.C. ALONG CONSTRUCTION JOINT. LOCATE AT SLAB MID-DEPTH BETWEEN ANCHORS. 4. IF T<7", TURN TENDON ANCHORS HORIZONTAL. T/2 1'-2"2'-0" CONSTRUCTION JOINT (NOTE 3) #4@24"x4'-0" T&B (BARS SPACED ALONG FULL LENGTH OF CONSTRUCTION JOINT) TENDON RADIUS REMARKS LESS THAN 10' CONSULT ENGINEER 10' TO 20' #3 HAIRPINS @ 12" > 20' NO HAIRPINS REQ'D 4"HOR. CURVATURE (NOTE 1) PROVIDE 2" CLEAR DISTANCE WITHIN TENDON MAX. OF 4 TENDONS PER HAIRPIN. ADD MULTIPLE HAIRPINS AS REQ'D @ 12" TO ENCLOSE ALL BANDED OR UNIFORM TENDONS WITHIN CURVE. NOTE 1: CLEAR SPACING BETWEEN TENDONS APPLIES WHETHER HAIRPINS REQ'D OR NOT."R""R"SCHED. SEE HAIRPINS (SEE SCHEDULE) # TENDONS HAIRPIN LENGTH 1-4 TENDONS 2'-0" 5-8 TENDONS 3-'0" > 8 TENDONS CONSULT ENGINEER T = THICKNESS OF SLAB ADD ONE #3 HAIRPIN OUTSIDE LAST ANCHOR TYP. EACH SIDE EDGE OF SLABAND 3" MIN. FOR VERTICALLIMIT OF BANDED ANCHORSSPACED AT 6" MIN. FOR HORIZ.UNIFORM TENDONS BANDED TENDONS #3 HAIRPIN AT EVERY ANCHOR (TYP.) TOTAL EQUAL TO NUMBER OF ANCHORS PLUS ONE EQUALLY SPACED BETWEEN ANCHORS 14" (T-2") NOTIFY STRUCTURAL ENGINEER OF RECORD IN WRITING OF OPENINGS NOT SHOWN ON PLANS OR OF CONDITIONS NOT COVERED BY THESE DETAILS OPENING STRAIGHT IN THIS AREA TENDONS SHALL BE MAX. 2'-0"3" MIN.MAX.2'-0"TYP. * 1'-6" MIN. 1#4x3'-0" MID-DEPTH (NOT REQUIRED AT CIRCULAR OPENINGS) DETAIL AT SINGLE OPENING UNIFORM TENDONS OR BANDED TENDONS WITH APPROVAL1#4 TOP & BOTTOM * PROVIDE STANDARD ACI 180° HOOK WHERE MINIMUM BAR EXTENSION PAST EDGE OF OPENING IS NOT POSSIBLE DETAIL AT SINGLE OPENING (EITHER DIMENSION GREATER THAN 2'-0") OPENING STRAIGHT IN THIS AREA TENDONS SHALL BE 6' - 0" MAX.3" MIN.6' - 0" MAX.TYP. * 2'-0" MIN. 2#5x5'-0" @4" MID-DEPTH 2#5@4" TOP & BOTTOM ADDITIONAL REINFORCING NOT REQUIRED FOR SLAB OPENING LESS THAN T DETAIL AT CLUSTERED PENETRATIONS STRAIGHT IN THIS AREA TENDONS SHALL BE 6' - 0" MAX.3" MIN.6' - 0" MAX.TYP. * 2'-0" MIN. 2#5x5'-0" @4" MID-DEPTH UNIFORM TENDONS 2#5@4" TOP & BOTTOM M IN . 2 " MAX. 1'-6" 1#5 UNIFORM TENDONS 45°BANDED TENDONSEDGE OF SLAB #4@12" TOP TEMPERATURE REINFORCING MAX. 1'-0"0.5 "L"TYPICAL2'-0" MIN.BANDED TENDONS"L"12" MAX. SPACINGSLAB REINFORCING1.5 T1.5 T12" MAX. SPACING SLAB REINFORCING 1.5 T 1.5 T COLUMN COL.UNIFORM TENDONS BANDED TENDONST = THICKNESS OF SLAB 1.5 T12" MAX. SPACING SLAB REINFORCING 1.5 T 1.5 T COLUMN COL.TENDONSBANDEDUNIFORM TENDONS 12" MAX. SPACINGSLAB REINFORCINGT= THICKNESS OF SLAB NOTES: 1. INSTALL A MINIMUM OF 2 STUDRAILS PER COLUMN FACE. 2. WHERE EDGE OF SLAB IS FLUSH WITH COLUMN FACE, STUDRAILS SHALL BE INSTALLED AT LEAST 2" FROM SLAB EDGE. 3. SEE SPECIFICATIONS FOR STUDRAIL MANUFACTURER INFORMATION. 4. "Sr MAX" EQUALS TWICE THE EFFECTIVE SLAB DEPTH USED FOR DESIGN. CLR.3/4"H(TYP.) S (TYP.) So MAX.SrEQ(TYP.)EQEQTYPICAL STUDRAIL ARRANGMENT SECTION A-A AATHICKSLABCOVERTOPLLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:06 PMS3−12 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 8 TYPICAL DETAIL AT TENDON ANCHORAGE ZONE 6 TYPICAL INTERIOR NON-STRESSING END DETAIL 7 TYPICAL DETAIL AT CONSTRUCTION JOINT 4 TYPICAL DETAIL AT HORIZONTAL DEVIATIONS 5 TYPICAL BANDED TENDON ANCHORAGE DETAIL 10 TYPICAL DETAIL AT SLAB OPENING 1 TYPICAL TEMPERATURE REINF. AT SLAB EDGE 3 TYPICAL PLAN DETAIL AT INTERIOR COLUMN 2 TYPICAL PLAN DETAIL AT EXTERIOR COLUMN 9 TYPICAL STUDRAIL DETAIL STUDRAIL REINFORCING SCHEDULE MARK # COLUMN FACES # RAILS PER COLUMN STUDS PER RAIL H STUD Ø So S Sr Max REMARKS SR-1 3 9 6 6 1/2" 1/2" 2 1/2" 4 1/2" 1'-1" SR-2 3 11 9 6 1/2" 1/2" 2 1/2" 3 3/4" 1'-1" SR-3 3 9 8 6 1/2" 1/2" 2 1/2" 3 1/2" 1'-1" SR-4 4 12 5 6 1/2" 1/2" 2 1/2" 4 1/2" 1'-1" Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 END SUPPORT FIRST INTERIOR SUPPORT TYPICAL INTERIOR SUPPORT END SUPPORT "L" 6" MIN. 6" MIN.12'-6 1/2" 6" MIN. END SPAN LEFT END (LE) SHOWN, RIGHT END (RE) OPPOSITE HAND INTERIOR SPAN (I)CANTILEVER SPAN RIGHT CANTILEVER (RC) SHOWN, LEFT CANTILEVER (LC) OPPOSITE HAND 6" MIN."L2" 6" MIN. 6" MIN. "L3"SEE PLAN"T"SLAB THICKNESSCLR. 1 1/2" 0.25 "L" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L2" OR 0.30 "L3" 180° (ACI) STD HOOK (TYP.) NOTES: 1. SEE STRUCTURAL NOTES FOR TOP AND BOTTOM CLEAR COVERS (TYP.) 2. TEMPERATURE REINFORCING MAY BE INSTALLED AT THE TOP OR BOTTOM OF THE SLAB (CONTRACTOR'S OPTION) 3. TEMPERATURE REINFORCING SHOWN IS BASED ON A 5" THICK CONCRETE SLAB. FOR SLABS WITH A THICKNESS GREATER THAN 5" FOR SLABS WITH A SLAB OVERPOUR, SEE TABLE FOR TEMPERATURE REINFORCING. CLR. 1 1/2" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #4@12" #4@12" #4@12"#4@9" #4@12"#4@9" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #4@12" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #4@12" #4@12" TYPICAL LAP SPLICE TEMPERATURE REINFORCING AT SLAB OVER POURS TOTAL SLAB THICKNESS REINFORCING LESS THAN OR EQUAL TO 6" GREATER THAN 6" AND LESS THAN OR EQUAL TO 9" GREATER THAN 9" AND LESS THAN OR EQUAL TO 11" GREATER THAN 11" AND LESS THAN OR EQUAL TO 13" #4@18" #4@12" #4@10" #4@8" END SUPPORT FIRST INTERIOR SUPPORT TYPICAL INTERIOR SUPPORT END SUPPORT "L" 6" MIN. 6" MIN.12'-6 1/2" 6" MIN. END SPAN LEFT END (LE) SHOWN, RIGHT END (RE) OPPOSITE HAND INTERIOR SPAN (I)CANTILEVER SPAN RIGHT CANTILEVER (RC) SHOWN, LEFT CANTILEVER (LC) OPPOSITE HAND 6" MIN."L2" 6" MIN. 6" MIN. "L3"SEE PLAN"T"SLAB THICKNESSCLR. 1 1/2" 0.25 "L" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L2" OR 0.30 "L3" 180° (ACI) STD HOOK (TYP.) CLR. 1 1/2" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #4@12" #4@12" #4@12"#5@12" #4@9"#4@9" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #4@12" #4@18" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END. SEE NOTE 3. #5@12" #4@12" TYPICAL LAP SPLICE TYPICAL PARKING TYPICAL OFFICE END SUPPORT FIRST INTERIOR SUPPORT TYPICAL INTERIOR SUPPORT END SUPPORTSPLICESPLICESPLICE "L" 6" MIN. 6" MIN.12'-6 1/2" 6" MIN. END SPAN LEFT END (LE) SHOWN, RIGHT END (RE) OPPOSITE HAND INTERIOR SPAN (I)CANTILEVER SPAN RIGHT CANTILEVER (RC) SHOWN, LEFT CANTILEVER (LC) OPPOSITE HAND 0.5 "L" 0.125 "L" 0.5 "L1" 0.125 "L1"0.125 "L1" 6" MIN."L2" 6" MIN. 0.5 "L2" 0.125 "L2"0.125 "L2" 6" MIN. "L3"SEE PLAN"T"SLAB THICKNESSCLR. 1 1/2" 0.25 "L" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L" OR 0.30 "L1" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L1" OR 0.30 "L2" GREATER 0.30 "L2" OR 0.30 "L3" 180° (ACI) STD HOOK (TYP.) NOTES: 1. SEE STRUCTURAL NOTES FOR TOP AND BOTTOM CLEAR COVERS (TYP.) 2. TEMPERATURE REINFORCING MAY BE INSTALLED AT THE TOP OR BOTTOM OF THE SLAB (CONTRACTOR'S OPTION) CLR. 1 1/2"TYPICAL LAP SPLICE TYPICAL LAP SPLICE TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END "B3" BAR "B2" BAR "B1" BAR "T1" BAR "T5" BAR "T2" BAR "T6" BAR "T3" BAR "T6" BAR "T3" BAR "T2" BAR "T7" BAR "T4" BAR TYP.0" TYP.0" TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END "B3" BAR "B2" BAR TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END "B3" BAR "B2" BAR "T2" BAR "L" SUPPORT SUPPORT SEE PLAN"T"SLAB THICKNESSSPLICE 0.25 "L" LAP SPLICE CLASS "B"0" 0.125 "L" 0.5 "L" "B2" BAR "B3" BAR TEMPERATURE BARS CONT. AND EMBED A DEVELOPMENT LENGTH EACH END NOTE: SEE STRUCTURAL NOTES FOR TOP AND BOTTOM CLEAR COVERS (TYP.) 0.125 "L" CLEAR 1 1/2" 180° (ACI) STD HOOK (TYP.) 0.25 "L" "T1" BAR "T1" BAR"T5" BAR CLEAR 1 1/2"0" SLAB SCHEDULE ABBREVIATION LIST TYPE DESCRIPTION S LE RE LC RC SIMPLE LEFT END RIGHT END LEFT CANTILEVER RIGHT CANTILEVER LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:12 PMS3−21 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL SLAB REINFORCEMENT DIAGRAM (ONE-WAY CONTINUOUS SLAB WITH BEAMS) 2 SLAB REINFORCEMENT DIAGRAM (ONE-WAY CONTINUOUS SLAB WITH BEAMS) SLAB SCHEDULE SLAB MARK SLAB THICK. "T" (inches) SLAB TYPE REINFORCING TEMP. BARS REMARKS"T1" "T2" "T3" "T4" "T5" "T6" "B1" "B2" "B3" S1 5" LE #5@12" #5@12"#5@12" #4@18" EXTEND LEFT END OF T1 BARS STRAIGHT, 5'-0" PAST LEFT SUPPORT S2 5" I #4@9"#4@12" #4@18" EXTEND T3 BARS TO HOOK AT FAR RIGHT SUPPORT S3 5" RE #4@12" #4@18" S4 5" RE #5@12"#5@12" #4@18" EXTEND RIGHT END OF T1 BARS STRAIGHT, 5'-0" PAST RIGHT SUPPORT S5 5" LE #4@12" #5@9"#5@9" #4@18" S6 5" I #5@12"#4@9" #4@18" S7 5" I #5@9"#4@9" #4@18" S8 5" RE #5@9"#5@9" #4@18" EXTEND RIGHT END OF T1 BARS STRAIGHT, 5'-0" PAST RIGHT SUPPORT S9 5" LE #4@12"#4@12" #4@18" EXTEND LEFT END OF T3 BARS TO HOOK AT FAR LEFT SUPPORT S10 5" RE #4@12"#4@12" #4@18" S11 5" S #4@12"#4@12" #4@18" S12 5" LE #4@12" #4@12"#4@12" #4@18" EXTEND LEFT END OF T1 BARS STRAIGHT, 5'-0" PAST LEFT SUPPORT S13 5" I #4@12"#4@12" #4@18" S14 5" RC #4@12"#4@12" #4@12" #4@18" S15 5" LC #4@12"#4@12"#4@12" #4@12" #4@18" S16 5" LE #4@12" #4@12"#4@12" #4@18" S17 5" LE #4@12" #4@9"#4@12" #4@18" EXTEND LEFT END OF T1 BARS STRAIGHT, 5'-0" PAST LEFT SUPPORT S18 5" I #4@12"#4@12" #4@18" EXTEND T3 BARS TO HOOK AT FAR RIGHT SUPPORT S19 5" I #4@12" #4@18" S20 5" RE #4@12"#4@12" #4@18" EXTEND RIGHT END OF T1 BARS STRAIGHT, 5'-0" PAST RIGHT SUPPORT S21 5" LE #4@12" #5@12"#4@9" #4@18" S22 5" I #4@9"#4@12" #4@18" S23 5" I #5@12"#4@9" #4@18" S24 5" RE #4@9"#4@9" #4@18" EXTEND RIGHT END OF T1 BARS STRAIGHT, 5'-0" PAST RIGHT SUPPORT S25 5" S #5@6"#5@6" #4@18" EXTEND T1 BARS 5'-0" STRAIGHT PAST CONTINUOUS SUPPORT S26 5" S #4@12"#4@12" #4@18" AT LEFT SUPPORT, EXTEND LEFT END OF T1 BARS STRAIGHT, 5'-0" PAST SUPPORT S27 6 1/2" LE #4@12" #4@12"#4@12" #4@15" S28 6 1/2" S #4@12"#4@9" #4@15" S29 6" S #4@12"#4@12" #4@18" EXTEND LEFT END OF T2 BARS 5'-0" PAST LEFT SUPPORT, HOOK RIGHT END OF T2 BARS AT RIGHT SUPPORT S30 5" LE #4@9"#4@12" #4@18" EXTEND RIGHT END OF T1 BARS STRAIGHT, 5'-0" PAST RIGHT SUPPORT S31 5" LE #4@12" #4@12"#4@12" #4@18" EXTEND LEFT END OF T1 BARS 5'-0" STRAIGHT PAST LEFT SUPPORT; EXTEND T3 BARS TO HOOK AT FAR RIGHT SUPPORT S32 5" LE #4@12" #4@12"#4@12" #4@18" EXTEND LEFT END OF T1 BARS 5'-0" STRAIGHT PAST LEFT SUPPORT S33 6" LE #4@12" #4@9"#4@12" #4@18" EXTEND LEFT END OF T1 BARS STRAIGHT, 5'-0" PAST LEFT SUPPORT S34 5" RC #4@9"#4@12" #4@18" Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 3"1 1/2"2'-6" MAX. NOTES: 1. ALL TOP & BOTTOM SLAB BARS INTERRUPTED BY THE OPENING SHALL BE REPLACED WITH ADDITIONAL REINFORCING EQUAL TO THAT INTERRUPTED. PLACE HALF OF THE ADDITIONAL REINFORCING ON EACH SIDE OF OPENING AND EXTEND IT A DEVELOPMENT LENGTH BEYOND EDGE OF OPENING. 2. BOXED OUT OPENINGS, RECESSED BOXES, AND PIPE SLEEVE CLUSTERS SHALL BE TREATED AS FOR SLAB OPENINGS. 3. FOR OPENINGS NOT MEETING THESE CONDITIONS, CONSULT WITH ENGINEER. 2#5 AT CENTERLINE OF SLAB - TYPICAL OPENING - SQUARE, RECTANGULAR, OR ROUND (600in.² MAX.)ARCH.SEET/SLAB TYPICAL T/SLAB AT DEPRESSION PER PLANSLAB DEPTHSEE PLAN"H"SLAB REINFORCING SEE PLANSEE PLAN"H"SLAB REINFORCING SEE PLAN(TYPICAL) LAP SPLICE "H"Z-BAR SAME SIZE & SPACING AS SLAB REINFORCING 2'-0" MIN. TOP REINFORCEMENT CONSTRUCTION JOINT TEMP. REINFORCEMENT BOTTOM REINFORCEMENT 1 1/2"x1 1/2"x6" LONG KEY AT 2'-0" SPACING SEE PLAN"H"SLAB REINFORCING SEE PLAN (TYPICAL) LAP SPLICE Z-BAR SAME SIZE & SPACING AS SLAB REINFORCING S/2 S S T & B SLAB BARS - SEE SCHEDULE S = TEMP. BAR SCHEDULED SPACING TEMP. BARS CONT. - SEE SLAB SCHEDULE CONCRETE BEAM - SEE SCHEDULE S/2 S S T & B SLAB BARS - SEE SCHEDULE S = TEMP. BAR SCHEDULED SPACING TEMP. BARS CONT. - SEE SLAB SCHEDULE CONCRETE BEAM - SEE SCHEDULESEE PLAN"H"MIN. 2'-0""H"EDGE OF DEPRESSION SLAB REINFORCING SEE PLAN (TYPICAL) LAP SPLICE #4 NOSING Z-BAR SAME SIZE & SPACING AS SLAB REINFORCING SEE PLAN"H"MIN. 2'-0""H"EDGE OF DEPRESSION SLAB REINFORCING SEE PLAN2'-9" MIN.8" 1 1/2" CLR #4@10" #4@8" BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN FACADE - SEE ARCH.2'-9" MIN.6" 1 1/2" CLR. #5@8" #4@12" BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN METAL STUD WALL - SEE ARCH.3'-6" MIN.8" 1 1/2" CLR #4@10" #4@8" BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN SECTION A: FACADE - SEE ARCH. BARRIER CABLES - SEE ARCH.2'-9" MIN.6" 1 1/2" CLR BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN #5@8" #4@12" METAL STUD WALL - SEE ARCH. BEAM REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN FACADE - SEE ARCH. SLAB REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN FACADE - SEE ARCH. SLAB REINF. NOT SHOWN FOR CLARITY T/SLAB VARIES/SLOPES FACADE - SEE ARCH. SEE ARCH. SEE ARCH. FOR ROOFING AND INSULATION5'-0" MAX.#4@12" 6'-0" 3'-0" 2#4 CONT. 8" EQ EQ #4@12" CONT. #4@12" T/PARAPET SEE ARCH.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:17 PMS3−22 08.14.18TYPICAL FRAMING SECTINS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 TYPICAL REINFORCING DETAIL AT SLAB OPENING 2 TYPICAL DETAIL AT SLAB DEPRESSION 3 TYPICAL DETAIL AT SLAB DEPRESSION 4 TYPICAL DETAIL AT SLAB DEPRESSION 5 TYPICAL DETAIL AT CONSTRUCTION JOINT 6 TYPICAL SECTION AT SLAB THICKNESS CHANGE 7 TYPICAL LAYERING DETAIL AT BEAMS AT INTERIOR BEAMS 8 TYPICAL LAYERING DETAIL AT BEAMS AT EDGE BEAMS 9 TYPICAL SECTION AT SLAB DEPRESSION (EDGE PERPENDICULAR TO SLAB SPAN) 10 TYPICAL SECTION AT SLAB DEPRESSION (EDGE PARALLEL TO SLAB SPAN) 11 TYPICAL SECTION AT EXTERIOR IMPACT CURB 12 TYPICAL SECTION AT INTERIOR IMPACT CURB SUPPORTING METAL STUD WALL 13 TYPICAL SECTION AT IMPACT CURB/BARRIER WALL Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 15 TYPICAL SECTION AT EXTERIOR BARRIER CABLES14A 14 TYPICAL SECTION AT EXTERIOR IMPACT CURB SUPPORTING METAL STUD WALL 16 TYPICAL SECTION AT OFFICE PERIMETER 17 TYPICAL SECTION AT RESIDENTIAL PERIMETER 18 TYPICAL SECTION AT ROOF PERIMETER 08/14/18 STANDARD ACI 90° HOOK TYP. NOTE 2 NOTE 2 (TYP.) NOTES: 1. 2. TOP AND BOTTOM COVER TO BE 3/4" UNLESS NOTED OTHERWISE. AT LEAST TWO (2) BOTTOM BARS SHALL PASS WITHIN THE COLUMN CORE, BE ANCHORED AT EXTERIOR SUPPORTS, AND USE CLASS B LAP SPLICES. END SPAN INTERIOR SPAN (I)CANTILEVER SPAN MIN. 6""L""L1""L2""L3"SEE PLAN"T"SLAB THICKNESSCL'R 1 1/2" CL'R 1 1/2" SPLICE LAP SPLICE LAP SPLICE LAP END SUPPORT FIRST INTERIOR SUPPORT END SUPPORTFIRST INTERIOR SUPPORT LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:19 PMS3−23 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL CONTINUOUS TWO-WAY SLAB REINF. PLACEMENT DIAGRAM Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 VERTICAL REINFORCEMENT SPACED AT DESIGN INTERVALS TO CONTINUE ABOVE LINTELS CORNERWALL OPENINGS REINF. AT DOOR OPENINGS SIM. CONTRACTION JOINT SEE PLAN REINF. SPACING REINF. & GROUT ALL CELLS UNDER LINTEL BEARING AND PER CMU WALL OPENING REINFORCEMENT SCHEDULE DOWELS TO MATCH VERTICAL REINF. TYP. CONTRACTION JOINT SILL BEAM W/1#5 ADD HORIZ. JOINT REINF. BELOW CMU SILL EXTEND 2'-0" EA. SIDE OF OPENING LINTEL - SEE SCHEDULE 8" MIN. BEARING EACH END U.N.O. OPENING ADD HORIZ. JOINT REINF. ABOVE LINTEL EXTEND 2'-0" EA. SIDE OF OPENING HORIZ. JOINT REINF. @ 16" ABOVE T/SLAB DO NOT RUN HORIZ. JT. REINF. THROUGH CONTRACTION JOINT NOTES: 1. SEE STRUCTURAL NOTES FOR MAXIMUM SPACING OF CONTROL JOINTS. 2. LOCATE CONTROL JOINTS 2'-0" MINIMUM FROM SIDES OF OPENINGS B/SUPPORT T/SUPPORT 8 S3-31 ____________AT NON-LOAD BEARING WALLS ONLY NOTE: REINFORCING SIZE SHALL MATCH ADJACENT WALL REINFORCING. PROVIDE MATCHING FOUNDATION DOWELS, U.N.O. CELLS PER TABLE ABOVE REINFORCE AND GROUT OPENING WIDTH "W" REINFORCE AND GROUT 3 CELLS (TYP.) REINFORCE AND GROUT 5 CELLS (TYP.) NOTE: ALTERNATE BLOCK COURSES - TYP. REINFORCE AND GROUT 3 CELLS (TYP.) CMU WALL OPENING REINFORCEMENT SCHEDULE OPENING WIDTH "W" VERTICAL REINFORCEMENT (EACH SIDE) UP TO 6'-0" 6'-0" TO 8'-0" 8'-0" TO 12'-0" 2 BARS TO MATCH TYPICAL WALL REINFORCING 3 BARS TO MATCH TYPICAL WALL REINFORCING 4 BARS TO MATCH TYPICAL WALL REINFORCING AT OPENINGS AT INTERSECTIONS AT CORNERS AT ENDS ___________5 S3-31 ___________5 S3-31 REINF. BAR(S) TO MATCH HORIZ. REINF. (ALTERNATE HOOK) AT INTERSECTION CORNER BAR(S) TO MATCH HORIZ. REINF. AT CORNER2'-0"2'-0"2'-0"2'-0" NOTE: REINFORCING SIZE SHALL MATCH ADJACENT WALL REINFORCING. FOR UNREINFORCED WALLS, USE #4 BARS. PROVIDE MATCHING FOUNDATION DOWELS, U.N.O. CELLS PER TABLE ABOVE REINFORCE AND GROUT OPENING WIDTH "W" REINFORCE AND GROUT CORNER CELLS (TYP.) REINFORCE AND GROUT CORNER CELLS (TYP.) NOTE: ALTERNATE BLOCK COURSES - TYP. REINFORCE AND GROUT 2 CELLS (TYP.) CMU WALL OPENING REINFORCEMENT SCHEDULE OPENING WIDTH "W" VERTICAL REINFORCEMENT (EACH SIDE) UP TO 6'-0" 6'-0" TO 8'-0" 8'-0" TO 12'-0" 2 BARS TO MATCH TYPICAL WALL REINFORCING 3 BARS TO MATCH TYPICAL WALL REINFORCING 4 BARS TO MATCH TYPICAL WALL REINFORCING AT OPENINGS AT INTERSECTIONS AT CORNERS AT ENDS ___________5 S3-31 ___________5 S3-31 CUT JOINT REINFORCEMENT AND ADD LAPPING WIRE OR USE WELDED INTERSECTION BEND AND WELD OR TIE WITH EQUIVALENT WIRE PLANS STANDARD WEIGHT HORIZONTAL JOINT REINFORCING @ 16"MIN.8"MIN. LAP 1'-4" REINFORCE AND GROUT EACH SIDE OF CONTRACTION JOINT. BOND BEAM REINFORCING AT CONTRACTION JOINT BOND BEAM REINFORCING IS TERMINATED 2" FROM EACH SIDE OF CONTRACTION JOINT. SIZE AND SPACING SEE PLAN FOR REINFORCING PROVIDE 4'-0" LONG SMOOTH 1/2" DIA. DOWELS ACROSS THE JOINT. NUMBER OF DOWELS TO MATCH NUMBER OF BOND BEAM REINFORCING. PREVENT BOND BETWEEN BAR AND GROUT WITH GREASE OR PLASTIC SLEEVE. CAP ALL DOWELS TO ALLOW 1" OF MOVEMENT. LOCATION OF CONTRACTION JOINT BELOW. REINFORCE AND GROUT EACH SIDE OF CONTRACTION JOINT. WALL REINFORCING AT CONTRACTION JOINT SIZE AND SPACING SEE PLAN FOR REINFORCING CONTRACTION JOINT W/SHEAR LUGS STOP TYPICAL HORIZONTAL JOINT REINFORCING AT EACH SIDE OF CONTRACTION JOINT. CONTRACTION JOINT MATERIAL W/SHEAR LUGS BACKER ROD OF THE HEAD JOINT)DEPTH OF CAULKING (ONE HALF THE WIDTHSET FIRST COURSE IN FULL MORTAR BEDDING VERTICAL REINFORCING. LAP AND HOLD IN POSITION AS REQUIRED. SEE PLAN FOR SIZE AND LOCATION FOUNDATION OR FLOOR SLAB CMU MORTAR CROSS WEBS ADJACENT TO FILLED CELLS GROUT FILLED CELL. PLACE AND CONSOLIDATE GROUT PER SPECIFICATIONS OR IN 5'-0" MAX. LIFTS. STOP GROUT 1 1/2" FROM TOP OF CMU HORIZONTAL JOINT REINFORCING (SEE SPECIFICATIONS) STARTING AT FIRST COURSE ABOVE FOUNDATION. LAP SPLICES 16". USE PREFAB L's & T's AT WALL INTERSECTIONS. NOTE: SEE STRUCTURAL NOTES AND DETAILS FOR REINFORCEMENT SIZE AND SPACING. BOND BEAM STEEL CLEAN OUT OPENINGS AT GROUT FILLED CELL LOCATIONS FOR HIGH-LIFT GROUTING PER SPECIFICATIONS CONTRACTOR'S OPTION: U-SHAPED BOND BEAM MAY BE SUBSTITUTED FOR KNOCK-OUT BOND BEAM METAL LATH OR WIRE SCREEN OVER UN-GROUTED CELLS UNDER KNOCK-OUT BOND BEAM TO CONTAIN GROUT (SHEET METAL AND FELT ARE PROHIBITED) GROUT ALL CELLS SOLID BELOW GRADE SEE PLANS FOR TYPICAL WALL REINFORCING LINTEL REINFORCEMENT WALL OPENING DEPTHLINTELBOTTOM REINFORCING (SEE SCHEDULE) PROVIDE 3/4" COVER ALL AROUND BAR SECTION LINTEL DEPTH REINFORCING UP TO 4'-0" 8"2#4 BOTTOM 4'-0" TO 6'-0" 8"2#5 BOTTOM 6'-0" TO 8'-0" 16"2#5 BOTTOM 8'-0" TO 10'-0" 16"2#6 BOTTOM CONSULT ENGINEER ELEVATION 1" MIN. BEARING 8" MIN. OVER 10'-0" CMU WALL - SEE PLANS FOR REINF.ANCHOR IN FULLY GROUTED JOINT PTA-RN ANCHOR (3/8'' ROD AND NUT) AS MANUFACTURED BY HOHMANN & BARNARD, INC. OR APPROVED EQUAL @ 32'' (TYP.) MATERIAL COMPRESSIBLE FILLER IF REQUIRED BY ARCH. FOR FIRE RATING. GROUT REINFORCED CELLS SOLID BOND BEAM W/ 2#5 CONT. CMU WALL - SEE PLANS FOR REINF. DOWELS TO MATCH VERTICAL REINFORCING T/SLAB 1''LAP SPLICETYPICALB/BEAM OR SLAB A-A 3''AA L1 1/2x1 1/2x3/16 AT BEAMS SPANNING 20'-0'' OR MORE USE THIS CONNECTION (ONE END ONLY) CUT CMU AT BEARING AS REQUIRED FOR T/BEAM ELEVATION NOTE: FILL BLOCK CORES (2 CORES MINIMUM) BELOW BEAM BEARING W/ COARSE GROUT. REINFORCE EACH CORE W/ 1 (ONE) BAR TO MATCH ADJACENT WALL REINFORCING. BEARING PLATE 3/4''x7''x1'-0'' W/ 2-5/8'' DIA.x8'' LONG ANCHOR RODS AND SLOTTED HOLES BEARING PLATE 3/4''x7'' W/ 2-5/8'' DIA.x8'' LONG ANCHOR RODS (SLOTTED HOLES AT ONE END) NOTE: FILL BLOCK CORES (2 CORES MINIMUM) BELOW BEAM BEARING W/ COARSE GROUT. REINFORCE EACH CORE W/1 (ONE) BAR TO MATCH ADJACENT WALL REINFORCING. PERPENDICULAR TO WALL PARALLEL TO WALL PLAN PLAN SECTION ELEVATION TYP. T/BEAM SEE PLAN 1 1 CMU WALL - SEE PLANS FOR REINF. ANCHOR IN FULLY GROUTED JOINT PTA-RN ANCHOR (3/8'' ROD AND NUT) AS MANUFACTURED BY HOHMANN & BARNARD, INC. OR APPROVED EQUAL @ 32'' (TYP.) MATERIAL COMPRESSIBLE FILLER IF REQUIRED BY ARCH. FOR FIRE RATING. GROUT REINFORCED CELLS SOLID BOND BEAM W/ 2#5 CONT. CMU WALL - SEE PLANS FOR REINF. DOWELS TO MATCH VERTICAL REINFORCING T/SLAB 1''LAP SPLICETYPICALB/BEAM OR SLAB A-A 3''AA LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:24 PMS3−31 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL CMU WALL REINFORCING - ELEVATION 2 TYP REINF. AT LOAD BEARING CMU WALLS CORNERS, ENDS, INTERSECTIONS & OPENINGS 3 TYPICAL BOND BEAM REINF. AT INTERSECTING CMU WALL 4 TYP. REINF. AT NON-LOAD BEARING CMU WALLS CORNERS, ENDS, INTERSECTIONS & OPENINGS 5 TYPICAL JOINT REINF. AT INTERSECTING CMU WALLS 6 TYPICAL CONTRACTION JOINT DETAILS 7 TYPICAL CMU WALL CONSTRUCTION 8 CMU LINTEL SCHEDULE 9 TYPICAL CMU WALL ANCHORAGE 11 TYPICAL BEAM BEARING AT CMU WALLS 10 TYPICAL CMU WALL ANCHORAGE Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 MIDDLE HEIGHTOF THE FLOOR3"6"CONTINUOUS GALVANIZED PLATE EMBED PLATE AT EACH FLOOR AND AT MID- HEIGHT OF EACH FLOOR T/RAMP T/RAMP T/RAMP T/RAMP BARRIER CABLES #4 STIRRUPS AND TIES @ 4" C/C SEE COLUMN SCHEDULE FOR VERTICAL REINFORCEMENT T/BEAM SEE FOR DETAILS NOT SHOWN 1/S3-41 SLEEVE E.O.S. COLUMN - SEE SCHEDULE #4 STIRRUPS AND TIES @4"SEE FOR DETAILS NOT SHOWN BARRIER CABLES SPACED AT 4"O.C.3"3"1/S3-41 SEE FOR DETAILS NOT SHOWN #4 TIES @4" c/cBARRIER CABLES SPACED AT 4" O.C. T/BEAM 1/S3-41 TENDON ANCHOR POCKET FORMER CUT OFF EXCESS TENDON AND DRY PACK POCKET AFTER STRESSING SLEEVE- FILL WITH NON- SHRINK GROUT AFTER CABLE INSTALLATION 1/2" GALV. BARRIER CABLE, REFER TO SPECIFICATIONS. PROVIDE 3.0k/CABLE EFFECTIVE TENSION U.N.O. ON PLAN CONCRETE COLUMN, POST, OR WALL NOTE: 1. ANCHORAGE SHALL BE PLACED TO AVOID INTERFERENCE WITH COLUMN VERTICAL STEEL AND TIES. GROUT ALL POCKETS SOLID WITH NON-SHRINK GROUT POST - SEE SCHEDULE #4 STIRRUPS @4" C/C FROM FLOOR TO FLOOR SEE FOR DETAILS NOT SHOWN 1/2" Ø BARRIER CABLES 1/S3-41 SLEEVE 1/2" GALV. BARRIER CABLE, REFER TO SPECIFICATIONS. PROVIDE 3.0k/CABLE EFFECTIVE TENSION U.N.O. ON PLAN CONCRETE COLUMN, POST, OR WALL 1/2" Ø BARRIER CABLES GALV. 1/2"X5" PLATE CONT. W/ 3/4"Ø HOLES FOR CABLES GALVANIZED 1/2"x6"x1'-8" EMBED PLATE W/ (3) 3/4"Ø x 6" HEADED STUDS @ 8" EDGE OF SLAB CONCRETE COLUMN 7 TYPICAL ELEVATION AT RAMP CABLE GUIDE 8 TYPICAL ELEVATION AT BARRIER CABLE ANCHOR COLUMN 5 TYPICAL DETAIL AT BARRIER CABLE ANCHOR COLUMN 4 TYPICAL ELEVATION AT BARRIER CABLE ANCHOR COLUMN 1 TYPICAL DETAIL AT BARRIER CABLE ANCHOR 2 DETAIL AT BARRIER CABLE ANCHOR POST 3 TYPICAL DETAIL AT BARRIER CABLE GUIDE 6 TYPICAL DETAIL AT RAMP CABLE GUIDE LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:27 PMS3−41 08.14.18TYPICAL FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 OUTLINE OF MECH. UNIT PUNCH HOLES (TYP.) IN TOP FLANGE COORDINATE W/ MANUF. PEDESTALS & FOOTINGS CONCRETE PEDESTALS BOLTS (TYP.)TOPFLANGEHOLES PEDESTALAND BEAMCONTRACTOR VERIFY DIMENSIONS & WEIGHT W/ EQUIPMENT MANUFACTURER BEFORE FABRICATION. 1/4" CAP PL. PC HSS5x5x1'-3" LONG T/PEDESTAL6"W.P.W.P.MIN.T/PARAPET EL. T/ROOF 2'-0"HSS8x8x1/4W.P. 7'-6" T/HSS EL. HSS8x8 HSS5x 5x1/4HSS8x8 20"x20" PEDESTAL W/8#7 VERT. & #3 TIES @4" TYP.15'-0"FRAME A: 18'-8", FRAME B: 21'-0"1/4 3/4" DIA DRAIN HOLE TYP.PLANSEEEQ EQ #4@12"#4@12" 8" HSS8x8 GLASS SCREEN WALL - SEE ARCH. LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 0.5 - LOADING DOCK 707'-6" 1 HSS12x12x3/8 HSS12x12x3/8 HSS12x12x3/8 HSS12x12x3/8LEVEL 0.5-LOADING DOCK 707'-6" DETENTION VAULT 701'-0"LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:31 PMS3−51 08.14.18FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL PLAN AT COOLING TOWER SUPPORT 2 TYPICAL SECTION AT PODIUM ROOF SCREENWALL 4 SECTION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 STANDARD AISC SHEAR CONNECTION SEE PLAN B/CROSS BEAM = T/TROLLEY BEAM W14 CROSS BEAM - SEE PLAN ___________2 S3-52 1/2" EMBED PLATE (4)-3/4" DIA. x 6" LONG HEADED STUDS 3 1/2" 5" 3 1/2"3 1/2"11"3 1/2"SECTION A-A A A A A STANDARD AISC SHEAR CONNECTION CONCRETE COLUMN - SEE PLAN CONCRETE COLUMN - SEE PLAN T/SLAB SEE PLAN S20 TROLLEY BEAM - SEE PLAN LEVEL P3 FRAMING - SEE PLAN S20 TROLLEY BEAM - SEE PLAN STIFFENER PLATE (NS/FS) TYP. 1 1/2" (4)-3/4" DIA. A325 BOLTS W14 CROSS BEAM - SEE PLAN COLUMN TYP. 3 SIDES 3/16 TYP. 1 1/2" 3/8" STIFFENER PLATE EACH SIDE S20 TROLLEY BEAM W14 CROSS BEAM 1/2" EMBED PLATE (6)-3/4" DIA. x 6" LONG HEADED STUDS 3 1/2" 5" 3 1/2"4"8"8"4"SECTION A-A STANDARD AISC SHEAR CONNECTION A A CONCRETE BEAM - REINFORCEMENT NOT SHOWN FOR CLARITY T/STEEL SEE PLAN FOR TOP OF WALL DETAIL SEE 9/S3-31 12" CMU WALL S20 TROLLEY BEAM LEVEL P3 FRAMING - REINFORCEMENT NOT SHOWN FOR CLARITY CONCRETE BEAM - REINFORCEMENT NOT SHOWN FOR CLARITY CONCRETE WALL - SEE PLAN LEVEL P3 SEE PLAN 12" CMU WALL - SEE PLAN DASHED LINE INDICATES LIMIT OF LEVEL P3 FRAMING 8" CMU WALL - SEE PLAN FOR TOP OF WALL DETAIL SEE 9/S3-31 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 1.5 - RES. LOBBY 715'-3" LEVEL 0.5 - LOADING DOCK 707'-6" F E.9 CB (12 x 70) CB (12 x 24)12" THICK CONCRETE WALLf'c = 5,000 PSI12" CMU WALL - SEE PLAN 3/8" STIFFENER PLATE EACH SIDE S20 TROLLEY BEAM W14 CROSS BEAM TYP. 1 1/2" TYP. 3 SIDES 3/16 8 F 7.85.8 6.85.7 E.9 5.9 1'-3" 1'-3"22'-6"1'-3" 1'-3" 17'-4"2'-6" 8'-6 13/16" 1'-0"3'-8"7'-4"2'-10 1/8"3'-11 1/2"1'-4"6" THICK WALL #4@12" VERT. #4@12" HORIZ. 5000 PSI 14#7 VERT. #3 TIES @12" 5000 PSI 12#7 VERT. #3 TIES @12" 5000 PSI 12#7 VERT. #3 TIES @12" 5000 PSI 1'-0" 14#7 VERT. #3 TIES @12" 5000 PSI 14#7 VERT. #3 TIES @12" 5000 PSI EQEQLLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:35 PMS3−52 08.14.18FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SECTION 2 DETAIL 3 SECTION6SECTION 4 SECTION 7 SECTION AT TRANSFORMER VAULT WALL 5 SECTION 8 PARTIAL PLAN - TRANSFORMER VAULT COLUMNS & WALLS Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 CONCRETE COLUMN - SEE PLAN T/RAMP VARIES CONCRETE IMPACT CURB - SEE X/S3-XX 8" CONCRETE IMPACT CURB - SEE X/S3-XX CONCRETE BEAM - SEE PLAN T/SLAB SEE PLAN CONCRETE BEAM - SEE PLAN T/WALL SEE ARCH. T/WALL SEE ARCH. SEE 11/S3-22 RAISED SLAB ON POLYSTYRENE FILL -SEE 1/S3-01 INTERSTITIAL LEVEL SEE PLAN AMENITY LEVEL SEE PLAN RAISED SLAB ON POLYSTYRENE FILL - T/SLAB SEE PLAN TRANSFER WALL W/ OPENING - SEE PLAN C A.7 SLAB REINF. NOT SHOWN FOR CLARITY T/SLAB SEE PLAN FACADE - SEE ARCH. 8"8"GLASS HANDRAIL - SEE ARCH. TOPPING SLAB - SEE ARCH.8"8" 8" FACADE - SEE ARCH.PLANSEELAP SPLICE CLASS "B" #4@12" 2#4 CONT. T/SLAB SEE PLAN LAP SPLICE CLASS "B" Z-BARS TO MATCH SIZE AND SPACING OF ADJACENT BARS 6#4 CONT. #4@12" 8" SLAB REINF. NOT SHOWN FOR CLARITY SEE ARCH. #4@12" CONT. #4@12" T/CURB SEE ARCH. T/SLAB VARIES/SLOPES T/SLAB SEE PLAN WALL SYSTEM - SEE ARCH.2 1/2" 3" 2 1/2"2 1/2"4 1/2"4 1/2"2 1/2"FACE OF CONCRETE COLUMN/WALL EMBED PL. 1/2" W/ (6)-3/4" DIA. x 6" LONG HEADED STUDS4" BEAM & PL. STANDARD SHEAR CONNECTION (SIZE, GRADE, AND NUMBER OF BOLTS AS REQUIRED) SNUG TIGHT AND MAR END THREADS. PROVIDE LONG HORIZONTAL SLOTTED HOLDES IN WING PLATE OR 2L'S SECTION A-AAA HSS HANGERS SEE PLAN LEVEL 9 - O1 SEE PLAN T/SLAB @ STAIR PLATFORM SEE PLAN CONCRETE BEAM & HSS HANGER BENT PL. 1/4", TYP. W10 BEAMS - SEE PLAN BEAM REINF. NOT SHOWN FOR CLARITY, TYP.___________7 S3-53 SIM. ___________7 S3-53 EMBED PL. & HSS HANGER 2 1/2" 3" 2 1/2"2 1/2"3"2 1/2"EMBED PLATE 1"B/CONC. BEAM HSS HANGER 1/4 PL. 1/2"x5"x0'-5" EA. SIDE OF POST W/ (2)-3/4" DIA. THROUGH BOLTS IN 2" LONG VERTICAL SLOTTED HOLES. HAND TIGHTEN NUTS AND MAR THREADS. EMBED PLATE 1/2"x8"x8" W/ (4)-3/4" DIA. x 6" LONG HEADED STUDS HANDRAIL - SEE ARCH. CONCRETE TOPPING - SEE ARCH. AND LANDSCAPE DRAWINGS. BEAM REINF. NOT SHOWN FOR CLARITY 8" 8" T/SLAB SEE PLAN EQ EQ #4@12" #4@12" CONT. #4@12" #4@12" CONT. EQ EQ T/SLAB SEE PLAN SEE SCHEDULE FOR BEAM REINF. CONCRETE TOPPING - SEE ARCH. AND LANDSCAPE DRAWINGS SEE PLAN FOR SLAB REINF. T/SLAB SEE PLAN TRANSFER BEAM - SEE PLAN (BEAM REINF. NOT SHOWN FOR CLARITY) CONCRETE TOPPING - SEE ARCH. AND LANDSCAPE DRAWINGS SEE PLAN FOR SLAB REINF. T/SLAB SEE PLAN SEE SCHEDULE FOR BEAM REINF. SEE PLAN FOR SLAB REINF. RAISED SLAB ON POLYSTYRENE FILL -SEE 1/S3-01 RAISED SLAB ON POLYSTYRENE FILL - POOL AMENITY - R1 LEVEL SEE PLAN INTERSTITIAL LEVEL SEE PLAN 6'-0"1'-0"1'-0" CONCRETE TOPPING - SEE ARCH. AND LANDSCAPE DRAWINGS #4@12" 2#4 CONT. BEAM REINF. NOT SHOWN FOR CLARITY LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:39 PMS3−53 08.14.18FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SECTION 2 SECTION Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 3 SECTION 4 SECTION 5 SECTION8SECTION 6 SECTION 7 DETAIL 9 SECTION 10 SECTION 11 SECTION 12 SECTION 13 SECTION 08/14/18 4 5 HSS12x8x1/2 (LSH)HSS12x8x1/2HSS12x8x1/2T/STEEL = 720'-10" LEVEL 1 SEE PLAN B A.3 HSS8x8x5/8HSS8x8x5/8 HSS8x8x5/8LEVEL 1 SEE PLAN T/STEEL = SEE ARCH. ___________3 S3-61 ___________3 S3-61 T/SLAB VARIES1"1/4 PL. 1/2"x8"x0'-8" EA. SIDE OF POST W/ (2)-3/4" DIA. THROUGH BOLTS IN 2" LONG VERTICAL SLOTTED HOLES. HAND TIGHTEN NUTS AND MAR THREADS. HSS8x8 EMBED PLATE 1/2"x12"x12" W/ (4)-3/4" DIA. x 3 1/2" LONG HEADED STUDS 3" 6" 3"3"6"3"SECTION A-A AA LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" CD HSS5x5x1/4 HSS5x5x1/4HSS5x5x1/4HSS5x5x1/4HSS5x5x1/4 HSS5x5x1/4B/STEEL = 934'-1"B/STEEL = 934'-1"___________4 S3-61 ___________4 S3-61 ___________4 S3-61 ___________4 S3-61 ___________6 S3-61 ___________6 S3-61 ___________6 S3-61 ___________6 S3-61 1"1/4 PL. 1/2"x5"x0'-5" EA. SIDE OF POST W/ (2)-3/4" DIA. THROUGH BOLTS IN 2" LONG VERTICAL SLOTTED HOLES. HAND TIGHTEN NUTS AND MAR THREADS. HSS5x5 EMBED PLATE 1/2"x12"x12" W/ (4)-3/4" DIA. x 6" LONG HEADED STUDS 3" 6" 3"3"6"3"SECTION A-A AA 3/16 HSS5x5 A A EMBED PLATE 1/2"x12"x12" W/ (4)-3/4" DIA. x 6" LONG HEADED STUDS 3" 6" 3"3"6"3"SECTION A-A LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:43 PMS3−61 08.14.18FRAMING SECTIONS AND DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851FRAME ELEVATION AT OFFICE LOBBY 2 FRAME ELEVATION AT OFFICE LOBBY 3 DETAIL 5 FRAME ELEVATION AT AMENITY LEVEL BIFOLD DOORS 4 DETAIL 6 DETAIL Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 STAGGER ALT. LAPS 180° OPPOSITE SIDES LAP TIES A MINIMUM OF 6" AND PROVIDE 90° STANDARD HOOK #11 8 COLUMN TIE & STIRRUP SCHEDULE #3 * TIE & STIRRUP SPACING (INCHES) COL. VERT. REINF. LEAST COL. DIM. NOTES: 1. USE #4 TIES & STIRRUPS FOR #11 BARS. 2. TIES & STIRRUPS TO BE SPACED @ 4" AT COLUMNS W/ BARRIER CABLES. SEE BARRIER CABLE COLUMN DETAILS. #10 #9 #8 #7 #6 #5 8 8 8 8 8 8 10 10 10 10 10 10 10 12 12 12 12 12 12 10 14 14 14 14 14 16 16 16 16 18 18 18 20 18 18 22 18 18 16 14 12 10 16 14 12 10 16 14 12 10 14 12 10 12 10 8"10"12"14"16"18"20"22" AND OVER TYPE "T1" 20 BARS TYPE "T2" 16 BARS TYPE "T3" 14 BARS TYPE "T4" 18 BARS TYPE "T9" 6 BARS TYPE "T7" 10 BARS TYPE "T8" 8 BARS TYPE "T13" 8 BARS STAGGER ALT. LAPS 180° OPPOSITE SIDES LAP TIES A MINIMUM OF 6" AND PROVIDE 90° STANDARD HOOK TYPE "T14" 12 BARS TYPE "T5" 16 BARS TYPE "T6" 22 BARS TYPE "T10" 22 BARS TYPE "T11" 24 BARS TYPE "T12" 16 BARS TYPE "T15" 4 BARS TYPE "T16" 26 BARS TYPE "T17" 28 BARS PROVIDE CONCRETE STRENGTH PER COLUMN REQUIREMENTS. ONLY REQUIRED WHERE REQUIRED CONCRETE STRENGTH IS GREATER THAN 7,000 PSI.MIN. "D" MIN. 2'-0""D"INTEGRATE COLUMN AND BEAM/SLAB CONCRETE (PLACED MONOLITHIC). PROVIDE CONCRETE STRENGTH PER BEAM & SLAB REQUIREMENTS. EXTRA TIE REQUIRED AT END OF SPLICE (TYP.) NOTE: SEE COLUMN REINFORCING DIAGRAM FOR COLUMN TIE SPACING REQUIREMENTS LAP SPLICECLASS "B"DOWELS TO MATCH COLUMN VERTICAL REINFORCING STANDARD ACI 90° HOOK NOTE: S = TIE SPACING PER COLUMN SCHEDULE 1/2 STIES @ S2"TIES @ S/2CLEARSPANT/SLAB SEE PLAN T/FOUNDATION SEE PLAN (2) EXTRA TIES @ 3" AT BOTTOM OF BEND (TYP.) 6 (MIN.) 1 BAR BEND SPLICE (TYP.)CLASS "B" LAPEXTRA TIE REQUIRED AT END OF SPLICE (TYP.)CLEARSPAN1/2 STIES @ S2"TIES @ S/2WHERE BEAMS FRAME FROM FOUR DIRECTIONS INTO A COLUMN AND THE BEAM WIDTH ON EACH COLUMN FACE CONFINES A MIN. OF ¾ OF THE COLUMN WIDTH, TERMINATION OF TIES NOT MORE THAN 3" BELOW LOWEST REINFORCEMENT IN SHALLOWEST OF SUCH BEAMS SHALL BE PERMITTEDCLEARSPAN1/2 STIES @ S2"TIES @ S/2STANDARD ACI 90° HOOK EXTRA TIE REQUIRED AT END OF SPLICE (TYP.)LAP SPLICECLASS "B"LAP SPLICECLASS "B"OFFSET (TYP.) 3" OR GREATER DOWEL TO MATCH COLUMN VERTICAL REINFORCING FROM ABOVENOTE: SEE COLUMN REINFORCING DIAGRAM FOR COLUMN TIE SPACING REQUIREMENTS EXTRA TIE REQUIRED AT END OF SPLICE (TYP.)LAP SPLICECLASS "B"LAP SPLICECLASS "B"OFFSET (TYP.) 3" OR GREATER DOWEL TO MATCH COLUMN VERTICAL REINFORCING FROM ABOVENOTE: SEE COLUMN REINFORCING DIAGRAM FOR COLUMN TIE SPACING REQUIREMENTS NOTE: S = TIE SPACING PER COLUMN SCHEDULE 1/2 STIES @ S2"TIES @ S/2CLEARSPANT/SLAB SEE PLAN T/FOUNDATION SEE PLAN (2) EXTRA TIES @ 3" AT BOTTOM OF BEND (TYP.)SPLICE (TYP.)CLASS "B" LAPEXTRA TIE REQUIRED AT END OF SPLICE (TYP.)CLEARSPAN1/2 STIES @ S2"TIES @ S/2COLUMN TIES IN SLAB CAN BE OMITTED WHEN THE SLAB THICKNESS BELOW THE SLAB REINFORCING IS LESS THAN ONE-HALF THE SCHEDULED TIE SPACING FOR THE COLUMN BELOW.CLEARSPAN1/2 STIES @ S2"TIES @ S/2STANDARD ACI 90° HOOK SLAB REINFORCING - SEE PLAN 6 (MIN.) 1 BAR BEND L3x3 CONT. 1/2" DIA. x 6" LONG STUDS @ 2'-0" COLUMN SEE SCHEDULE FOR SIZE AND REINF. 3 A.3 2.8 8" 26"8"8"24" 12"6"30"4'-9 1/4" 4'-5 3/4" 9 1/4" 15#7 VERT. #3 TIES @ 4" 5000 PSI 15#7 VERT. #3 TIES @ 4" 5000 PSI 6"30"SEE 4/S4-01 FOR COLUMN REINFORCING DIAGRAM LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:47 PMS4−01 08.14.18CONCRETE COLUMN DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851COLUMN TIE PATTERNS 2 TYP. COLUMN/FLOOR JOINT PUDDLING DETAIL3TYPICAL COLUMN AT TRANSFER BEAM 4 TYPICAL COLUMN REINFORCING DIAGRAM AT BEAMS 5 TPICAL COLUMN DETAIL AT 3" OR GREATER OFFSET (GRAVITY COLUMNS AT BEAMS) 6 TYPICAL COLUMN DETAIL AT 3" OR GREATER OFFSET (GRAVITY COLUMNS AT SLABS) 7 TYPICAL COLUMN REINFORCING DIAGRAM AT FLAT SLABS 8 TYPICAL LOADING DOCK COLUMN CORNER PROTECTION STEEL 9 COLUMN REINFORCEMENT DETAIL Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" E.0.7 C.1D.1E.8 A.6.1 A.3B.1 SEE 2/S4-05 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI D.2 SEE 4/S3-41 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" E.0.7F C.1D.1E.8 A.6.1B.2B.9 A.3C.7.1D.0.5 B.1C.2 SEE 1/S4-05 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI D.2 SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:14:54 PMS4−05 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 1 SERIES COLUMN ELEVATION2GRIDLINE 1 SERIES COLUMN ELEVATION (CONTINUED) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 0.5 - LOADING DOCK 707'-6" AFB.1 SEE 2/S4-06 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI D.2 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" AFB.9D.0.5 B.1 SEE 1/S4-06 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#11 T1 - #4@6" 7000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 7000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 16"x30" 14#9 T3 - #3@9" 5000 PSI D.2 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 0.5 - LOADING DOCK 707'-6" 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI DETENTION VAULT 701'-0" SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:00 PMS4−06 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 1.8 TO 2 SERIES COLUMN ELEVATION2GRIDLINE 1.8 TO 2 SERIES COLUMN ELEVATION (CONTINUED)3 DETENTION VAULT SERIES COLUMN ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" ABE.0.7F A.3 SEE 3/S4-07 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 12000 PSI DETENTION VAULT 701'-0" 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI SEE 9/S4-02 SEE 9/S4-02 SEE 9/S4-02 SEE 9/S4-02 SEE 9/S4-02 SEE 9/S4-02 SEE 9/S4-02 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" ABE.0.7F A.3 A.1 SEE 2/S4-07 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#11 T1 - #4@6" 7000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x30" 14#9 T3 - #3@9" 5000 PSI LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 0.5 - LOADING DOCK 707'-6" C.1D.1 12"x18" 6#7 T9 - SEE SCHEDULE 12000 PSI 12"x18" 6#7 T9 - SEE SCHEDULE 12000 PSI DETENTION VAULT 701'-0" 18"x18" 8#7 T8 - SEE SCHEDULE 5000 PSI D.2 SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:08 PMS4−07 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2 GRIDLINE 2.8 TO 3 SERIES COLUMN ELEVATION3GRIDLINE 2.8 TO 3 SERIES COLUMN ELEVATION (CONTINUED)1 GRIDLINE 2.3 SERIES COLUMN ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" ABFD.4 C.8C.9 SEE 2/S4-08 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 16"x30" 14#7 T3 - SEE SCHEDULE 12000 PSI 30"x30" 24#11 (GR. 75) T11 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 30"x30" 20#11 (GR. 75) T1 - #4@12" 12000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@12" 10000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@12" 10000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@12" 10000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@12" 10000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@12" 10000 PSI 18"x24" 10#7 T7 - SEE SCHEDULE 12000 PSI D.2 SEE 4/S3-41 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" ABFD.0.5D.4 A.1C.2 SEE 1/S4-08 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@6" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#11 T1 - #4@6" 7000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 18"x42" 18#11 (GR. 75) T4 - #4@6" 10000 PSI 18"x72" 28#11 (GR. 75) T16 - #4@3" 7000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x30" 14#9 T3 - #3@9" 5000 PSI D.2 SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:16 PMS4−08 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 3.9 TO 4 SERIES COLUMN ELEVATION2GRIDLINE 3.9 TO 4 SERIES COLUMN ELEVATION (CONTINUED) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 1.5 - RES. LOBBY 715'-3" LEVEL 0.5 - LOADING DOCK 707'-6" ABF SEE 2/S4-09 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI SEE 4/S3-41 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" ABFE.2 A.1 SEE 1/S4-09 MATCHLINE LEVEL 31 - PENTHOUSE 1061'-9" 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#11 T1 - #4@6" 7000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 30" Ø 12#10 T14 - SEE SCHEDULE 7000 PSI 12"x12" 4#7 T15 - SEE SCHEDULE 5000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x30" 14#9 T3 - #3@9" 5000 PSI SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:22 PMS4−09 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 4.9 TO 5 SERIES COLUMN ELEVATION2GRIDLINE 4.9 TO 5 SERIES COLUMN ELEVATION (CONTINUED) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 1.5 - RES. LOBBY 715'-3" LEVEL 0.5 - LOADING DOCK 707'-6" ABF MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x54" 28#7 T17 - #3@6" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI SEE 2/S4-10 E.9 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" ABFE.1 A.1 MATCHLINE LEVEL 31 - PENTHOUSE 1061'-9" 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#11 T1 - #4@6" 7000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 18"x36" 16#10 T12 - SEE SCHEDULE 7000 PSI 18"x36" 16#10 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#10 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#10 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#10 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#7 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#7 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#7 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#7 T12 - SEE SCHEDULE 5000 PSI 18"x36" 16#7 T12 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 7000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 18"x30" 14#7 T3 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 7000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 7000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 7000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 7000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 7000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 5000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 5000 PSI 18"x18" 8#11 (GR. 75) T8 - #4@6" 5000 PSI 18"x18" 8#9 T8 - #3@6" 5000 PSI 18"x18" 8#9 T8 - #3@6" 5000 PSI 18"x18" 8#9 T8 - #3@6" 5000 PSI 18"x18" 8#9 T8 - #3@6" 5000 PSI 18"x18" 8#9 T8 - #3@4" 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 30" Ø 12#10 T14 - SEE SCHEDULE 7000 PSI 12"x12" 4#7 T15 - SEE SCHEDULE 5000 PSI SEE 1/S4-10 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x36" 16#9 T12 - #3@9" 5000 PSI 18"x18" 8#9 T8 - #3@6" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x30" 14#9 T3 - #3@9" 5000 PSI LEVEL 30 - ROOF 1049'-6" D LEVEL 31 - PENTHOUSE 1061'-9" 12"x12" 4#10 T15 - SEE SCHEDULE 5000 PSI 12"x12" 4#10 T15 - SEE SCHEDULE 5000 PSI 12"x12" 4#10 T15 - SEE SCHEDULE 5000 PSI SCREEN WALL A 1068'-2"12"x12" 4#10 T15 - #3@6" 5000 PSI 12"x12" 4#10 T15 - #3@6" 5000 PSI 12"x12" 4#10 T15 - #3@6" 5000 PSI SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:30 PMS4−10 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 5.7 TO 6 SERIES COLUMN ELEVATION2GRIDLINE 5.7 TO 6 SERIES COLUMN ELEVATION (CONTINUED) 3 GRIDLINE 6.4 SERIES COLUMN ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 1.5 - RES. LOBBY 715'-3" LEVEL 0.5 - LOADING DOCK 707'-6" F CD A.7 SEE 2/S4-11 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x54" 28#7 T17 - #3@6" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI E.9 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" F CDE.1 A.7 SEE 1/S4-11 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#10 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 7000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 7000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24"x30" 16#7 T5 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 30" Ø 12#10 T14 - SEE SCHEDULE 7000 PSI 30" Ø 12#7 T14 - SEE SCHEDULE 7000 PSI 24"x46" 22#7 T6 - #3@6" 7000 PSI 30" Ø 12#7 T14 - SEE SCHEDULE 7000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x30" 16#9 T5 - #3@9" 5000 PSI 24"x30" 16#9 T5 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:37 PMS4−11 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 6.7 TO 7.1 SERIES COLUMN ELEVATION2GRIDLINE 6.7 TO 7.1 SERIES COLUMN ELEVATION (CONTINUED) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 1.5 - RES. LOBBY 715'-3" LEVEL 0.5 - LOADING DOCK 707'-6" BFCDE A.7 SEE 2/S4-05 MATCHLINE SEE 2/S4-05 MATCHLINE SEE 2/S4-12 MATCHLINE 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 24#11 (GR. 75) T11 - #4@18" 12000 PSI 30"x30" 24#11 (GR. 75) T11 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#9 T1 - #3@9" 12000 PSI 30"x30" 20#9 T1 - #3@9" 12000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 24#11 (GR. 75) T11 - #4@18" 12000 PSI 30"x30" 24#11 (GR. 75) T11 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#11 T1 - #4@18" 12000 PSI 30"x30" 20#9 T1 - #3@9" 12000 PSI 30"x30" 20#9 T1 - #3@9" 12000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x30" 20#7 T1 - #3@9" 12000 PSI 30"x54" 28#7 T17 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #4@4" 12000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI 30"x36" 22#11 (GR. 75) T10 - #4@12" 12000 PSI E.9 SEE 4/S3-41 SEE 4/S3-41 SEE 4/S3-41 SEE 4/S3-41 SEE 4/S3-41 SEE 4/S3-41 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" BFCDD.7EE.2 A.7 SEE 2/S4-05 MATCHLINE SEE 2/S4-05 MATCHLINE SEE 1/S4-12 MATCHLINE 30"x30" 20#7 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 7000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 7000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 7000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24"x24" 16#7 T2 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 7000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 7000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 18"x26" 10#7 T7 - SEE SCHEDULE 5000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#9 T1 - #3@9" 10000 PSI 30"x30" 20#7 T1 - #3@9" 10000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 24" Ø 8#7 T13 - SEE SCHEDULE 7000 PSI 30"x30" 22#11 (GR. 75) T10 - #4@18" 10000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 24"x24" 16#9 T2 - #3@9" 5000 PSI 18"x26" 10#9 T7 - #3@9" 5000 PSI 18"x26" 10#9 T7 - #3@9" 5000 PSI 24" Ø 8#9 T13 - #3@9" 5000 PSI SHEET NOTES: 1.SEE S4-01 FOR TYPICAL COLUMN DETAILS AND TIE REINFORCEMENT DIAGRAMS. COLUMN SCHEDULE KEY: COLUMN SIZE VERTICAL REINFORCEMENT TIE REINFORCEMENT DIAGRAM - TIE SPACING CONCRETE STRENGTH LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:44 PMS4−12 08.14.18COLUMN ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 GRIDLINE 7.8 TO 8 SERIES COLUMN ELEVATION2GRIDLINE 7.8 TO 8 SERIES COLUMN ELEVATION (CONTINUED) Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LINTEL BAR SCHEDULE OPENING SIZE REINFORCING LESS THAN 5'-0" 5'-1" TO 7'-0" 7'-1" TO 9'-0" MORE THAN 9'-0" 2#5 2#6 2#7 CONSULT ENGINEER FLOOR LINE SPLICELAPSPLICE LAP SPLICELAPACI STANDARD HOOK WHERE MIN. EMBED. IS NOT POSSIBLE DOWELS TO MATCH JAMB BARS JAMB BARS TO MATCH VERT. REINF. LINTEL BARS - SEE SCHEDULE WHERE EXTENSION IS NOT POSSIBLE, EXTEND BARS AS FAR AS POSSIBLE AND PROVIDE STANDARD ACI HOOK FLOOR LINE SPLICELAPTYPICAL WALL REINFORCING JAMB BARS TO MATCH VERT. REINF. WHERE EXTENSION IS NOT POSSIBLE, EXTEND BARS AS FAR AS POSSIBLE AND PROVIDE STANDARD ACI HOOK LINTEL BARS - SEE SCHEDULE LENGTH DEVELOPMENT HAIRPINS TO MATCH HORIZ. REINFORCING TYP. WALL REINFORCING SECTION C JAMB 2-JAMB BARS TYP. WALL REINFORCING SECTION D JAMB SPLICE LAP 2-JAMB BARS U-BARS TO MATCH VERTICAL REINFORCING SECTION E ISOLATED WALL 48" OR LESS T/OPENINGT/OPENING HAIRPINS TO MATCH VERTICAL REINFORCING B/OPENING B/OPENING SECTION A LINTEL/SILL SECTION B LINTEL/SILL A OR BC OR D A OR BC OR D STANDARD 90° ACI HOOK SPLICELAPLINTEL BARS TYPICAL WALL REINFORCING U-BARS TO MATCH HORIZ. REINFORCINGSPLICELAPT/SLAB AT CONTINUOUS SLAB AT SLAB END 2x4 KEY CONTINUOUS 2x4 KEY CONTINUOUS ROUGHEN SURFACE SPLICELAPT/SLAB AT CONTINUOUS SLAB AT SLAB END ROUGHEN SURFACE ROUGHEN SURFACE U-BARS - SEE TABLE VERT. BAR U-BAR U-BAR TABLE #4 #4 #5 #5 #6 #6 #7 #7 #8 #8 #9 TO #11 #8 NOTES: (1) PLACE "T2" AND "B2" IN SECOND LAYER. (2) USE U-STIRRUPS AT BEAMS EXCEEDING 36" IN DEPTH. (3) SEE ELEV. FOR CONCRETE STRENGTH OF LINK BEAM. (4) SEE 6/S-501, 7/S-501 AND 8/S-501 FOR LINK BEAM DETAILS. 2""S1" STIRRUPS 2" DEVELOPMENT LENGTH T/SLAB FACE BARS PROVIDE 90 OR 180 HOOK REQ'D. FOR BAR DEVELOPMENT NOTE: COORDINATE PIPE SLEEVES WITH MECH. DWG'S. "T1" BARS "T2" BARS "B2" BARS "B1" BARS DEVELOPMENT LENGTH HORIZ. WALL REINF. -SEE WALL SECTION VERT. WALL REINF. -SEE WALL ELEV. LINK BEAM REINF. -SEE SECEDULE LINK BEAM STIRRUPS -SEE SCHEDULE LINK BEAM .. PLAN ELEVATION NOTE: SEE 5/S5-01 FOR BAR SCHEDULE HORIZ. WALL REINF. SEE WALL SECTIONS AND ELEVATIONS FACE BARS "B2" BARS SECOND LAYER "B1" BARS "T1" BARS "T2" BARS SECOND LAYER ROUGHEN SURFACE h<36""B3" BARS THIRD LAYER "T3" BARS THIRD LAYER HORIZ. WALL REINF. SEE WALL SECTIONS AND ELEVATIONS FACE BARS "B2" BARS SECOND LAYER "B1" BARS "T1" BARS "T2" BARS SECOND LAYER h>36"U-BARS .CLASS B LAP SPLICE ROUGHEN SURFACE "B3" BARS THIRD LAYER "T3" BARS THIRD LAYER CORNERINTERSECTION ENDWALL SPLICELAPSPLICE LAP U-BARS TO MATCH HORIZONTAL REINF. STANDARD 90° HOOKS 2 VERTICAL BARS TYPICAL U-BARS TO MATCH HORIZONTAL REINF. 2 VERTICAL BARS TYPICAL BOUNDARY ELEMENT @ WALL CORNER CLASS "B" LAP VERT. REINF. - SEE ELEV. FOR SIZE AND SPACING U-BARS TO MATCH HORIZONTAL BARS VERT. WALL REINFORCING @ 6"- SEE ELEV. FOR SIZE MINIMUM #6 BAR ZONE2'-0" BOUNDARYCLASS "B" LAP#3 J-TIES @ 12" IN BOUNDARY ZONE #3 CLOSED TIES @ 12" VERT. REINF. - SEE ELEV. FOR SIZE AND SPACING HORIZ. REINF. - SEE ELEV. FOR SIZE AND SPACING HORIZ. REINF. - SEE ELEV. FOR SIZE AND SPACING #3 J-TIES @ 12" WHERE CALLED FOR IN WALL ELEVATION BOUNDARY ELEMENT @ WALL END VERT. WALL REINFORCING @ 6"- SEE ELEV. FOR SIZE MINIMUM #6 BAR ZONE 2'-0" BOUNDARY CLASS "B" LAP #3 J-TIES @ 12" IN BOUNDARY ZONE #3 CLOSED TIES @ 12" VERT. REINF. - SEE ELEV. FOR SIZE AND SPACING HORIZ. REINF. - SEE ELEV. FOR SIZE AND SPACING U-BARS TO MATCH HORIZONTAL BARS #3 J-TIES @ 12" WHERE CALLED FOR IN WALL ELEVATION 2.8 B.8 BAR SIZE TO MATCH VERTICAL BARS SHOWN IN ADJACENT BOUNDARY ELEMENT - SEE SHEAR WALL "SW-1" ELEVATIONS SEE 4/S5-01 FOR DETAILS NOT SHOWN TIE SIZE AND SPACING TO MATCH HORIZONTAL REINFORCEMENT OF ADJACENT BOUNDARY ELEMENT - SEE SHEAR WALL "SW-1" ELEVATIONS SEE SHEAR WALL "SW-1" ELEVATIONS FOR VERTICAL REINFORCEMENT IN BOUNDARY ELEMENT 2.8 B.8 SEE SHEAR WALL ELEVATIONLENGTH OF BOUNDARY ELEMENTBAR SIZE TO MATCH VERTICAL BARS SHOWN IN ADJACENT BOUNDARY ELEMENT - SEE SHEAR WALL "SW-1" ELEVATIONS SEE 4/S5-01 FOR DETAILS NOT SHOWN TIE SIZE AND SPACING TO MATCH HORIZONTAL REINFORCEMENT OF ADJACENT BOUNDARY ELEMENT - SEE SHEAR WALL "SW-1" ELEVATIONS SEE SHEAR WALL "SW-1" ELEVATIONS FOR VERTICAL REINFORCEMENT IN BOUNDARY ELEMENT SEE SHEAR WALL "SW-1" ELEVATIONS FOR VERTICAL AND HORIZONTAL REINFORCEMENT SEE SHEAR WALL "SW-1" ELEVATIONS FOR VERTICAL AND HORIZONTAL REINFORCEMENT LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:50 PMS5−01 08.14.18SHEAR WALL DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL MINIMUM REINFORCING AT CONCRETE WALL OPENINGS 2 TYPICAL SHEAR WALL DETAIL AT FLOOR SLAB 3 TYPICAL SHEARWALL DETAIL AT TOP OF WALL 5 LINK BEAM SCHEDULE SHEAR WALL LINK BEAM REINFORCEMENT SCHEDULE MARK MINIMUM BM SIZE "T1" BARS "T2" BARS "T3" BARS "B1" BARS "B2" BARS "B3" BARS STIRRUPS (2) "S1" FACE BARS (E.F.) LB1 18x30 5#9 5#9 5#9 5#9 #4@4" #4@6" LB2 18x72 5#10 5#10 5#10 5#10 5#10 5#10 #4@4" #4@6" LB3 18x30 4#7 4#7 4#7 4#7 #3@4" #4@6" LB4 18x20 4#9 4#9 4#9 4#9 #4@4" #4@6" LB5 18x72 5#10 5#10 5#10 5#10 5#10 5#10 #4@4" #4@6" LB6 18x30 3#9 2#9 3#9 2#9 #3@4" #4@6" LB7 18x30 3#9 2#9 3#9 2#9 #3@4" #4@6" LB8 18x30 3#7 2#7 3#7 2#7 #3@4" #4@6" LB9 18x20 4#9 4#9 4#9 4#9 #4@4" #4@6" LB10 18x30 5#10 5#10 5#10 5#10 #4@4" #4@6" LB11 18x20 3#7 3#7 3#7 3#7 #3@4" #4@6" 6 TYPICAL SHEAR WALL LINK BEAM DETAIL 7 TYPICAL SECTION AT LINK BEAM DEPTH LESS THAN 36" 8 TYPICAL SECTION AT LINK BEAM DEPTH GREATER THAN 36" 9 TYPICAL REINFORCING AT WALL INTERSECTIONS DOUBLE MAT REINFORCING 4 SHEARWALL REINFORCING BOUNDARY DETAILS10DETAIL AT SHEAR WALL "SW-1" 11 DETAIL AT SHEAR WALL "SW-1" Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" B.8D.4 SEE 2/S5-05 MATCHLINE 18" WALLf'c = 7,000 PSI#10@6" VEF#10@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#10@6" VEF#9@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF(GR. 75)#10@6" VEF(GR. 75)10 S5-01 ____________ 11 S5-01 ____________#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEFNOTE 6#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#10@6" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#9@12" VEF#6@6" HEF #6@6" HEF #4@12" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #6@12" HEF #6@12" HEF 6'-0" BOUNDARY ELEMENT 14'-6" BOUNDARY ELEMENT NOTE 6NOTE 6NOTE 69'-0" BOUNDARY ELEMENT #6@6" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF D.2 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" B.8D.4 SEE 1/S5-05 MATCHLINEf'c = 5,000 PSIf'c = 7,000 PSI18" WALL#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF 6'-0" BOUNDARY ELEMENT 14'-6" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT #6@6" HEF #6@6" HEFLB11 (18 x 20) #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF D.2 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" B.8 SEE 4/S5-05 MATCHLINE 18" WALLf'c = 7,000 PSINOTE 6#9@12" VEF#8@12" VEF#9@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT NOTE 6NOTE 6D.2 LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" B.8 SEE 3/S5-05 MATCHLINE LEVEL 31 - PENTHOUSE 1061'-9"18" WALLf'c = 5,000 PSIf'c = 7,000 PSILB8 (18 x 30)#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#9@12" VEF#7@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@6" VEF#9@6 VEF#9@6" VEF#9@6" VEF#7@6" VEF#9@6" VEF#7@6" VEF#9@6" VEF#6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT #6@6" HEF #5@12" HEF #5@12" HEF D.2 #5@12" HEF#5@12" VEFSHEET NOTES: 1. 2. SEE S0 SERIES FOR STRUCTURAL NOTES. SEE S5-01 FOR TYPICAL SHEAR WALL DETAILS. 3. 4. SEE DETAIL 4/S5-01 FOR TIE REINFORCEMENT AT BOUNDARY ELEMENTS (HATCHED AREA). SEE DETAIL 4/S5-01 FOR VERTICAL STEEL REQUIREMENTS IN BOUNDARY ELEMENTS (HATCHED AREA). 5. 6. J-TIES REQUIRED IN SHEAR WALL BETWEEN BOUNDARY ELEMENTS WITHIN HATCHED AREA. DOWELS TO MATCH VERTICAL SHEAR WALL REINFORCEMENT.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:15:57 PMS5−05 08.14.18SHEAR WALL ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SHEAR WALL "SW-1A" ELEVATION2SHEAR WALL "SW-1B" ELEVATION3SHEAR WALL "SW-2A" ELEVATION4SHEAR WALL "SW-2B" ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" B.8D.4 SEE 2/S5-06 MATCHLINE LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30) LB4 (18 x 30)18" WALLf'c = 7,000 PSINOTE 6#9@12" VEF#9@12" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@12" VEF#7@12" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEFNOTE 6#9@12" VEF#9@12" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF 12'-2" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT NOTE 6NOTE 6#6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF D.2 LB4 (18 x 30) LB4 (18 x 30) LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" B.8D.4 SEE 1/S5-06 MATCHLINELB4 (18 x 30) LB5 (18 x 72) LB4 (18 x 20) LEVEL 31 - PENTHOUSE 1061'-9"18" WALLf'c = 5,000 PSIf'c = 7,000 PSILB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB6 (18 x 30) LB7 (18 x 30)LB7 (18 x 30) LB6 (18 x 30) LB4 (18 x 20)#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#7@12" VEF#6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF 4'-0" BOUNDARY ELEMENT 12'-2" BOUNDARY ELEMENT #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF D.2 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" 4 5.7 SEE 4/S5-06 MATCHLINE LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30)18" WALLf'c = 7,000 PSIMATCHLINE NOTE 6#9@12" VEF#9@12" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@12" VEF#7@12" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEFNOTE 6#9@12" VEF#9@12" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@6" VEF#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@12" VEF#7@12" VEFNOTE 6#9@12" VEF#9@12" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#7@12" VEF#6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF 7'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT NOTE 6NOTE 6NOTE 6LB1 (18 x 30) LB10 (18 x 30) LB10 (18 x 30) #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" 4 5.7 SEE 3/S5-06 MATCHLINE LB2 (18 x 72) LB1 (18 x 30) LEVEL 31 - PENTHOUSE 1061'-9"18" WALLf'c = 5,000 PSIf'c = 7,000 PSILB9 (18 x 20) MATCHLINE #7@6" VEF#9@6" VEF#7@12" VEF#7@12" VEF#7@6" VEF#9@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@12" VEF#9@12" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@12" VEF#9@12" VEF#9@12" VEF#5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF#6@12" HEF #6@6" HEF #6@6" HEF 4'-0" BOUNDARY ELEMENT 7'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT LB10 (18 x 30) #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF SHEET NOTES: 1. 2. SEE S0 SERIES FOR STRUCTURAL NOTES. SEE S5-01 FOR TYPICAL SHEAR WALL DETAILS. 3. 4. SEE DETAIL 4/S5-01 FOR TIE REINFORCEMENT AT BOUNDARY ELEMENTS (HATCHED AREA). SEE DETAIL 4/S5-01 FOR VERTICAL STEEL REQUIREMENTS IN BOUNDARY ELEMENTS (HATCHED AREA). 5. 6. J-TIES REQUIRED IN SHEAR WALL BETWEEN BOUNDARY ELEMENTS WITHIN HATCHED AREA. DOWELS TO MATCH VERTICAL SHEAR WALL REINFORCEMENT.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:05 PMS5−06 08.14.18SHEAR WALL ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SHEAR WALL "SW-3A" ELEVATION2SHEAR WALL "SW-3B" ELEVATION3SHEAR WALL "SW-4A" ELEVATION4SHEAR WALL "SW-4B" ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" 5 5.7 SEE 2/S5-07 MATCHLINE 18" WALLf'c = 7,000 PSILB3 (18 x 30)#10@6" VEF#10@6" VEF#6@6" HEF #6@6" HEF NOTE 6#10@6" VEF#4@6" HEF#10@6" VEF#10@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF NOTE 6#6@6" HEF LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" LEVEL 20 - R3 946'-0" LEVEL 21 - R4 956'-2" LEVEL 22 - R5 966'-4" LEVEL 23 - R6 976'-6" LEVEL 24 - R7 986'-8" LEVEL 25 - R8 996'-10" LEVEL 26 - R9 1007'-0" LEVEL 27 - R10 1017'-2" LEVEL 28 - R11 1027'-4" LEVEL 29 - R12 1037'-6" LEVEL 30 - ROOF 1049'-6" 5 5.7 SEE 1/S5-07 MATCHLINE LEVEL 31 - PENTHOUSE 1061'-9"18" WALLf'c = 5,000 PSIf'c = 7,000 PSI#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF #5@12" HEF 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT #5@12" HEF #5@12" HEF#5@12" HEF LEVEL 1 - OFFICE LOBBY 711'-0" LEVEL 2 - P2 735'-9" LEVEL 3 - P3 746'-9" LEVEL 4 - P4 757'-9" LEVEL 5 - P5 768'-1" LEVEL 6 - P6 778'-1" LEVEL 7 - P7 788'-1" LEVEL 8 - P8 798'-1" LEVEL 9 - O1 811'-3" LEVEL 10 - O2 825'-6" LEVEL 11 - O3 839'-9" LEVEL 12 - O4 854'-0" LEVEL 14 - O5 868'-3" LEVEL 15 - O6 882'-6" LEVEL 0.5 - LOADING DOCK 707'-6" 5 5.7 SEE 4/S5-07 MATCHLINE LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30) LB1 (18 x 30)18" WALLf'c = 7,000 PSILB1 (18 x 30)#10@6" VEF#6@6" HEF NOTE 6#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#9@6" VEF#5@12" VEF#7@12" VEF#9@6" VEFNOTE 6#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#10@6" VEFNOTE 6#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#10@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#7@6" VEF#5@12" VEF#5@12" VEF#9@6" VEFNOTE 6#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#8@12" VEF#8@12" VEF#7@12" VEF#7@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#5@12" VEF#6@6" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT #6@6" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF #6@12" HEF LEVEL 15 - O6 882'-6" LEVEL 16 - O7 896'-9" LEVEL 17 - INT 915'-1" LEVEL 18 - AMENITY - R1 923'-10" LEVEL 19 - R2 935'-10" 5 5.7 SEE 3/S5-07 MATCHLINELB1 (18 x 30) LB2 (18 x 72) LB1 (18 x 30)18" WALLf'c = 5,000 PSIf'c = 7,000 PSI#7@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#9@6" VEF#7@12" VEF#9@12" VEF#9@12" VEF#9@12" VEF#5@12" VEF#9@12" VEF#9@12" VEF#6@12" HEF #6@6" HEF #6@6" HEF #6@12" HEF #6@6" HEF #6@6" HEF #6@6" HEF 4'-0" BOUNDARY ELEMENT 4'-0" BOUNDARY ELEMENT #6@12" HEF #6@6" HEF #6@6" HEF SHEET NOTES: 1. 2. SEE S0 SERIES FOR STRUCTURAL NOTES. SEE S5-01 FOR TYPICAL SHEAR WALL DETAILS. 3. 4. SEE DETAIL 4/S5-01 FOR TIE REINFORCEMENT AT BOUNDARY ELEMENTS (HATCHED AREA). SEE DETAIL 4/S5-01 FOR VERTICAL STEEL REQUIREMENTS IN BOUNDARY ELEMENTS (HATCHED AREA). 5. 6. J-TIES REQUIRED IN SHEAR WALL BETWEEN BOUNDARY ELEMENTS WITHIN HATCHED AREA. DOWELS TO MATCH VERTICAL SHEAR WALL REINFORCEMENT.LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:11 PMS5−07 08.14.18SHEAR WALL ELEVATIONS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SHEAR WALL "SW-5A" ELEVATION2SHEAR WALL "SW-5B" ELEVATION3SHEAR WALL "SW-6A" ELEVATION4SHEAR WALL "SW-6B" ELEVATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 BEAM SCHEDULE ABBREVIATION LIST DESCRIPTIONTYPE LE I RE S LC RC SL SM SR SC LEFT END - START BEAM INTERIOR BEAM RIGHT END - END BEAM SINGLE SPAN BEAM LEFT CANTILEVER AND NEXT SPAN RIGHT CANTILEVER AND BACK SPAN STIRRUPS - LEFT STIRRUPS - MIDDLE STIRRUPS - RIGHT STIRRUPS - CANTILEVER SCHEDULE NOTES: 1. CLASS "B" LAP SPLICE - SEE STRUCTURAL NOTES. 2. WHICHEVER IS THE GREATER OF THE TWO VALUES. 3. PROVIDE ACI STANDARD 90° & 135° HOOKS AS DEPICTED. 4. FACE BARS NOT SHOWN IN ELEVATION FOR CLARITY. FACE BARS TO BE CONTINUOUS - PROVIDE CLASS "B" LAP SPLICES. 5. CONTRACTOR HAS THE OPTION OF DETAILING ONE LONG BAR WHERE BARS THE SAME SIZE AND SAME NUMBER ARE LAPPED WITH A CLASS "B" LAP SPLICE. 6. SUPPORT BARS NOT SHOWN. PROVIDE AS REQUIRED. 7.REINFORCING SCHEDULED WITH AN "L" OR "R" INDICATES REINFORCING PLACED AT LEFT OR RIGHT ENDS OF SPAN RESPECTIVELY. 8. BARS AT INTERIOR SUPPORTS ARE SCHEDULED WITH THE SPAN TO THE LEFT OF THE SUPPORT. BEAM TOP AND BOTTOM STEEL SLAB REINFORCING NOT SHOWN FOR CLARITY * COORDINATE REINFORCING CLEARANCES WITH STRUCTURAL NOTES (TYP.) GIRDER TOP AND BOTTOM STEEL GIRDER STIRRUP - SEE SCHEDULE FOR STIRRUP TYPE BEAM STIRRUP*END SUPPORT END SUPPORT SPLICE 0.5 "L" "L" CLEARSPAN 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. 0.125 "L"0.125 " L" B2 B3 T2 0.25 "L" TYP. NOTE 1 0.25 "L" NOTE 1 4'-0" MINIMUM (TYPICAL) DEVELOPMENT LENGTH OR TYP. NOTE 1 CLR. 2" B1 STIRRUPS (TYPICAL) B1 T1 T5 T1 T3 T6T3T6 SINGLE SPAN TYPE 1A STIRRUP (INTERIOR BEAM) "W""D"SEE NOTE 3 TYPE 1B STIRRUP (INTERIOR BEAM) "W""D"TYPE 1C STIRRUP (SPANDREL BEAM) "W""D"TYPE 1D STIRRUP (BEAM WITHOUT SLAB) "W""D"TYPE 1E STIRRUP (INTERIOR BEAM) "W""D"MAX. 1'-0" BEAM TOP BARS KEEP MIN. TWO BARS IN STIRRUP CORNERS, ADD EXTRA IN SLAB AT SIDE. TYPE 2A STIRRUP (INTERIOR BEAM) "W""D"SEE NOTE 3 0" TYPE 2B STIRRUP (INTERIOR BEAM) "W""D"0" TYPE 2C STIRRUP (SPANDREL BEAM) "W""D"0" TYPE 2D STIRRUP (BEAM WITHOUT SLAB) "W""D"0" "SL" "SM" "SR""SL" "SM" "SR""SC" LEFT CANTILEVER (LC)RIGHT END (RE) STIRRUPS AT OPPOSITE HAND MAX. 1'-0" END SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT END SUPPORT SPLICE 0.5 "L" SPLICE 0.5 "L1" SPLICE 0.5 "L2" "L" CLEARSPAN "L1" CLEARSPAN "L2" CLEARSPAN "L3" CANTILEVER END SPAN LEFT END (LE) SHOWN, RIGHT END (RE) OPPOSITE HAND INTERIOR SPAN (I)CANTILEVER SPAN RIGHT CANTILEVER (RC) SHOWN, LEFT CANTILEVER (LC) OPPOSITE HAND CLR. 2" 0.25 "L" SEE NOTE 2 0.33 "L" OR 0.33 "L1" SEE NOTE 2 0.33 "L" OR 0.33 "L1" 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. 0.3 "L" SPLICE 0.125 "L" TYP. NOTE 1 NOTE 1 NOTE 1 SPLICE 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. B7 SEE NOTE 3 TYPICAL B2 B3 TYP. NOTE 1 SEE NOTE 2 0.33 "L1" OR 0.33 "L2" SEE NOTE 2 0.33 "L1" OR 0.33 "L2" TYP. NOTE 1 TYP. NOTE 1 SEE NOTE 2 0.33 "L2" OR 1.0 "L3" NOTE 1 CLR. 2" 0.3 "L1" 0.125 "L1"0.125 " L1" SPLICE 0.125 "L2"0.125 " L2" NOTE 1 0.3 "L2" 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. NOTE 1NOTE 1 6" MIN. 2" STIRRUPS - SEE SCHEDULE "SC" B8B1 B9 B2 B3B4 B8 B2 B3B4 B5 B6 B10 T1 T5 T2 T6 T3 T2 T3 T6 T2 T4 T7 STIRRUPS (TYPICAL) CONTINUOUS SPAN LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:15 PMS6−01 08.14.18CONCRETE BEAM DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2 TYPICAL REINFORCEMENT LAYERING DIAGRAM 4 TYPICAL STIRRUP DETAILS 1 CONCRETE BEAM ELEVATIONS 3 NOT USED Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 DD/3D/3D/3SUPPORT SUPPORT SUPPORT 1'-0"LAP SPLICE CLASS "B" < 1.0 "L3" X < 0.25 "L" < 0.33 "L1" OR "L2" "T2" "T1", "T3", OR "T4" LAP SPLICE CLASS "B"1'-0""B2" "B2" OR "B5" "B2" OR "B6" SUPPORT SUPPORT SUPPORT 1'-0"≥ 1.0 "L3" X ≥ 0.25 "L" ≥ 0.33 "L1" OR "L2" "T2" "T1", "T3", OR "T4"1'-0""B8", "B9", OR "B10""B8", "B9", OR "B10" LAP SPLICE CLASS "B" LAP SPLICE CLASS "B" SUPPORT SUPPORT 1'-0""T6" OR "T7" "T5", "T6", OR "T7" LAP SPLICE CLASS "B"BEAM WIDTHSCHEDULEDFACE OF COLUMN SEE SCHEDULE TYP. SPACING -REINF. PER SCHEDULE 4" MIN.6" MIN.ADDL STIRRUPS TO MATCH BEAM STIRRUPS EACH SIDE OF SLEEVE EDGE OF BEAM SLEEVE NOTES: 1. MAINTAIN CONCRETE COVER REQUIREMENTS AT SLEEVES 2. PLACE VERTICAL BEAM PENETRATIONS ONLY AT LOCATIONS SHOWN ON STRUCTURAL DWGS. ALL OTHER VERTICAL PENETRATIONS MUST BE VERIFIED WITH STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION PLAN VIEW ADDL 4#7x5'-0"6" MIN.2 ADDL STIRRUPS @ 2" EACH SIDE OF OPENING NOTE: OPENINGS SHALL BE PLACED IN MIDDLE 1/3 SPAN OR CONSULT W/ ENGINEER6" MIN.T/SLAB B/SLAB B/BEAM 8" DIA. OPENING (MAX.) FACE BAR CRITERIA CONCRETE COVER Cc (IN.) MAX. BAR SPACING (IN.) 0 ≤ Cc ≤ 1 3/16 12 1 3/16 ≤ Cc ≤ 2 10 2 ≤ Cc ≤ 2 1/2 2 1/2 ≤ Cc ≤ 2 3/4 9 2 3/4 ≤ Cc ≤ 3 1/2 8 3 1/2 ≤ Cc ≤ 4 1/2 6 4 1/2 ≤ Cc ≤ 4 13/16 4 3 NOTES: 1. PROVIDE FACE BARS BY CRITERIA SHOWN FOR ALL BEAMS AND GIRDERS DEEPER THAN 36" UNLESS GIVEN OTHERWISE IN SCHEDULES OR DETAILS. 2. LAP FACE BARS WITH CLASS B LAP AT SPLICES. 3. SPACE FACE BARS EVENLY EACH FACE BETWEEN TOP AND BOTTOM REINFORCEMENT. 4. PROVIDE #5 BARS IF SIZE OF BAR IS NOT SPECIFIED. T/ BEAM OR GIRDER OR BEAM DEPTH "D"SCHEDULED GIRDEREQEQEQEQBEAM WIDTH "W" SCHEDULED GIRDER OR SCHEDULED OR DETAILED TOP REINFORCEMENT FACE BARS SEE CRITERIA ABOVE SCHEDULED OR DETAILED BOTTOM REINFORCEMENT FACE OF BEAM FACE BAR Cc SCHEDULED OR DETAILED STIRRUPS STIRRUP "a" PER SCHEDULE BEAM WIDTH BEAM1#5 CONT. ADDITIONAL T&B WHEN "a" EXCEEDS 3" 2#5 CONT. ADDITIONAL T&B WHEN "a" EXCEEDS 12" #3 U-BAR SPACED TO MATCH BEAM STIRRUPS WHEN "a" EXCEEDS 3" FACE BARS TO MATCH SCHEDULED FACE BARS WHEN "a" EXCEEDS 3". WIDEN AT OPENINGS OR EDGE OF SLAB VARIATIONS 3" 2" 2" 3" CONSTRUCTION JOINT NOTES: 1. ADDITIONAL STIRRUPS TO MATCH SCHEDULED BEAM STIRRUPS EA SIDE OF JOINT. 2. TOP & BOTTOM REINFORCING PER BEAM SCEDULE, CONTINUOUS THRU JOINT. 3. ADD #5X4'-0" FACE BARS EQUALLY SPACED ALONG EA. FACE OF BEAM. USE: 2#5 FOR D < 24" 3#5 FOR 24" < D < 36" 4#5 FOR 36" < D < 48" VERIFY WITH E.O.R. FOR BEAMS > 48" VERIFY WITH E.O.R. 4. SHEAR KEY WITH HEIGHT OF D/3 AND WIDTH OF W/2. CHAMFER EDGES AS REQ'D TO FACILITATE REMOVAL OF FORMING MATERIAL. 5. ROUGHEN SURFACE OUTSIDE OF SHEAR KEY OR PROVIDE EXPANDED METAL LATH EMBEDDED AT BULKHEAD. 6. CONSTRUCTION JOINT LOCATION. SEE STRUCTURAL SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS. SEE STRUCTURAL NOTES FOR RULES REGARDING LOCATIONS. NOTE 2 NOTE 1 NOTE 4 NOTE 5 NOTE 3 3" NOTE 6 BEAM BEAM 2'-0" MAX. SEE PLAN GIRDER - SEE PLAN BEAM - SEE PLAN BEAM - SEE PLAN 2 STIRRUPS MIN. SCHED. STIRRUPS @ 4" BEYOND BM. EXTENTS LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:19 PMS6−02 08.14.18CONCRETE BEAM DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL CONCRETE BEAM STEP DETAILS 2 TYP. VERTICAL BEAM PENETRATION DETAIL 3 TYPICAL HORIZONTAL BEAM PENETRATION 6 TYPICAL CONCRETE GIRDER AND BEAM FACE BARS CRITERIA 4 TYPICAL BEAM WIDENING DETAIL 5 NOT USED 8 TYPICAL CONSTRUCTION JOINT DETAIL 9 TYPICAL ADDITIONAL STIRRUPS AT BEAM OFFSET Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 7 NOT USED 08/14/18 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:26 PMS6−05 08.14.18CONCRETE BEAM SCHEDULE401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 CONCRETE BEAM SCHEDULE BEAM MARK "W" "D1" "D2" BEAM TYPE TOP BARS BOTTOM BARS FACE BARS (EA FACE) BEAM MARK STIRRUPS BEAM REMARKS"T1" "T2" "T3" "T4" "T5" "T6" "T7" "B1" "B2" "B3" "B4" "B5" "B6" "B7" "B8" "B9" "B10" SIZE TYPE (SPACING SHOWN IN INCHES) "SL" "SM" "SR" "SC" CB001 12" 23" 0" S - - - - 2#5 - - - 2#5 - - - - - - - - - CB001 #3 1C 9 9 9 -EXTEND B2 BARS TO HOOK AT SUPPORTS CB002 12" 23" 0" LC - - - - 2#7 - 2#7 2#5 2#5 - - 2#5 - - - - - - CB002 #3 1C 9 9 9 4 - CB003 12" 23" 0" S - - - - 3#7 - - 2#5 3#7 - - - - - - - - - CB003 #3 1C 9 9 9 -- CB004 8" 23" 0" S - 2#5 - - - - - - 2#5 - - - - - - - - - CB004 #3 1C 9 9 9 -EXTEND T2 & B2 BARS TO HOOK AT SUPPORTS CB005 30" 23" 0" LC - - - - 4#7 - 4#9 4#5 4#7 - - 4#5 - - - - - - CB005 #4 2C 9 9 9 4 - CB006 18" 23" 0" S - - - - 3#7 - - 2#5 3#7 - - - - - - - - - CB006 #3 1C 9 9 9 -- CB007 18" 23" 0" S - - - - 3#7 - - 2#5 3#7 - - - - - - - - - CB007 #3 1C 9 9 9 -- CB009 12" 23" 0" LC - - - 2#7 - - - - - - - 2#5 - - - - - - CB009 #3 1C - - - 4 STUB CANTILEVER; EXTEND T4 & B5 BARS TO HOOK AT RIGHT SUPPORT CB010 12" 23" 0" LE - - - - 3#5 3#5 - 2#5 3#5 - 3#5 - - - - - - - CB010 #3 1C 9 9 9 - HOOK (1)-T6 BAR AND (1)-B4 BAR AT STEP IN BEAM WIDTH AT RIGHT SUPPORT CB011 8" 23" 0" RE - - - - 2#5 - - 2#5 2#5 - - - - - - - - #3@4" CB011 #3 1C 4 4 4 -- CB012 24" 23" 0" RC - - - - 4#7 - 4#7 2#5 4#7 - - - - - - - - - CB012 #3 1C 9 9 9 4 EXTEND B4 BARS TO END OF CANTILEVER CB013 18" 23" 0" S - - - - 4#7 - - 2#5 4#7 - - - - - - - - - CB013 #3 1C 9 9 9 -- CB014 18" 23" 0" LE 3#7 - - - - - - - - - - - - - - - - #3@4" CB014 #3 1C 4 4 4 - EXTEND T1 BARS TO LAP WITH T2 BARS IN ADJACENT SPAN CB015 18" 23" 0" RE 3#7 2#5 - - - - - - - - - - - - - - - - CB015 #3 1C 9 9 9 -- CB016 12" 23" 0" LE 2#7 2#5 2#7 - - - - 2#5 2#7 - 2#5 - - - - - - - CB016 #3 1C 9 9 9 -EXTEND T3 BARS TO HOOK AT FAR RIGHT SUPPORT CB017 12" 23" 0" RE - - - - - - - 2#5 2#5 - - - - - - - - - CB017 #3 1C 9 9 9 -- CB018 30" 23" 0" LC - - - - - - 7#9 - - - - 4#5 - - - - - - CB018 #4 2C - - - 4 EXTEND T7 & B5 BARS TO HOOK AT SUPPORT CB019 24" 23" 0" LE 3#7 2#5 3#7 - - - - 2#5 3#7 - 2#5 - - - - - - - CB019 #3 1C 9 9 9 -- CB020 24" 23" 0" I - 2#5 3#7 - - - - - 3#7 - 2#5 - - - - - - - CB020 #3 1C 9 9 9 -- CB021 24" 23" 0" RE 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - CB021 #3 1C 9 9 9 -- CB022 18" 23" 0" S - - - - 4#7 - - 2#5 4#7 - - - - - - - - - CB022 #3 1C 9 9 9 -- CB023 24" 23" 0" S - - - - 5#9 - - 2#5 5#9 - - - - - - - - - CB023 #3 1C 6 6 6 -- CB024 18" 23" 0" S 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - CB024 #3 1C 9 9 9 -- CB025 18" 30" 0" S 3#7 2#5 - - - - - 2#5 3#9 - - - - - - - - - CB025 #3 1C 9 9 9 -- CB026 18" 53" 0" S 4#7 2#5 - - - - - 2#5 4#9 - - - - - - - - - CB026 #3 1C 9 9 9 -- CB027 30" 23" 0" LE - - - - 5#9 5#9 - - - - - - - 5#7 5#7 - - - CB027 #3 2C 9 9 9 -- CB028 30" 23" 0" I - - - - - 5#9 - - - - - - - - - 5#7 - - CB028 #3 2C 9 9 9 -- CB029 30" 23" 0" I - - - - - 5#9 - - - - - - - - - 5#7 - - CB029 #3 2C 9 9 9 -- CB030 30" 23" 0" RE - - - - 5#9 - - - - - - - - 5#7 - - - - CB030 #3 2D 9 9 9 -- CB031 30" 23" 0" LC - - - - - - 5#9 - - - - - - - - - 5#7 - CB031 #3 2C - - - 4 - CB032 30" 23" 0" S - - - - - 5#9 - - 5#7 - - - - - - - - - CB032 #3 2C 9 9 9 - EXTEND B2 BARS A DEVELOPMENT LENGTH INTO SUPPORTS CB033 18" 35" 0" S 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - #3@4" CB033 #3 1C 4 4 4 -- CB034 30" 35" 0" LC - - - - 4#7 - 5#9 4#5 4#7 - - 4#5 - - - - - - CB034 #4 2C 9 9 9 4 - CB035 18" 23" 0" S 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - CB035 #3 1C 9 9 9 -- CB036 30" 23" 0" LE - - - - 5#9 6#9 - - - - - - - 5#7 5#7 - - - CB036 #3 2C 9 9 9 -- CB037 30" 23" 0" I - - - - - 6#9 - - - - - - - - - 5#7 - - CB037 #3 2C 9 9 9 -- CB038 30" 23" 0" I - - - - - 6#9 - - - - - - - - - 5#7 - - CB038 #3 2C 9 9 9 -- CB039 30" 23" 0" RE - - - - 5#9 - - - - - - - - 5#7 - - - - CB039 #3 2C 9 9 9 -- CB040 30" 23" 0" LC - - - - - - 5#9 - - - - - - - - - 5#7 - CB040 #3 2C - - - 4 - CB041 30" 23" 0" S - - - - - 6#9 - - 5#7 - - - - - - - - - CB041 #3 2C 9 9 9 - EXTEND B2 BARS A DEVELOPMENT LENGTH INTO SUPPORTS CB042 18" 20" 0" S - - - - 3#7 - - - 3#7 - - - - - - - - - CB042 #3 1C 6 6 6 -EXTEND B2 BARS TO HOOK AT SUPPORTS CB043 12" 20" 0" LC - - - - 2#7 - 2#7 2#5 2#5 - - 2#5 - - - - - - CB043 #3 1C 6 6 6 4 - CB044 12" 20" 0" S - - - - 3#7 - - 2#5 3#7 - - - - - - - - - CB044 #3 1C 6 6 6 -- CB045 8" 20" 0" S - 2#5 - - - - - - 2#5 - - - - - - - - - CB045 #3 1C 6 6 6 -EXTEND T2 & B2 BARS TO HOOK AT SUPPORTS CB046 6" 23" 0" S - 2#5 - - - - - - 2#5 - - - - - - - - - CB046 #3 1C 9 9 9 -EXTEND T2 & B2 BARS TO HOOK AT SUPPORTS CB047 12" 23" 0" LE 2#7 2#5 2#7 - - - - 2#5 2#7 - 2#5 - - - - - - - CB047 #3 1C 9 9 9 -- CB048 12" 23" 0" RE 2#7 2#5 - - - - - 2#5 2#7 - - - - - - - - - CB048 #3 1C 9 9 9 -- Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 END SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT END SUPPORT SPLICE 0.5 "L" SPLICE 0.5 "L1" SPLICE 0.5 "L2" "L" CLEARSPAN "L1" CLEARSPAN "L2" CLEARSPAN "L3" CANTILEVER END SPAN LEFT END (LE) SHOWN, RIGHT END (RE) OPPOSITE HAND INTERIOR SPAN (I)CANTILEVER SPAN RIGHT CANTILEVER (RC) SHOWN, LEFT CANTILEVER (LC) OPPOSITE HAND CLR. 2" 0.2 "L" SEE NOTE 2 0.2 "L" OR 0.2 "L1" SEE NOTE 2 0.2 "L" OR 0.2 "L1" 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. 0.3 "L" SPLICE 0.2 "L" TYP. NOTE 1 NOTE 1 NOTE 1 SPLICE 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. B7 SEE NOTE 3 TYPICAL B2 B3 TYP. NOTE 1 SEE NOTE 2 0.2 "L1" OR 0.2 "L2" SEE NOTE 2 0.2 "L1" OR 0.2 "L2" TYP. NOTE 1 TYP. NOTE 1 SEE NOTE 2 0.2 "L2" OR 1.0 "L3" NOTE 1 CLR. 2" 0.3 "L1" 0.2 "L1"0.2 " L1" SPLICE 0.2 "L2"0.2 " L2" NOTE 1 0.3 "L2" 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. NOTE 1NOTE 1 6" MIN. 2" STIRRUPS - SEE SCHEDULE "SC" B8B1 B9 B2 B3B4 B8 B2 B3B4 B5 B6 B10 T1 T5 T2 T6 T3 T2 T3 T6 T2 T4 T7 STIRRUPS (TYPICAL) "ℓ""ℓ1""ℓ2""ℓ3" CANTILEVER EQ EQ EQ EQ EQ EQ"b""a""b""b""e""d"POINT 0.1 "ℓ" INFLECTION POINT 0.1 "ℓ1" INFLECTION POINT 0.1 "ℓ" INFLECTION POINT 0.1 "ℓ2" INFLECTION POINT 0.1 "ℓ1" INFLECTION POINT 0.1 "ℓ2" INFLECTION POINT 0.1 "ℓ3" INFLECTION "c""c"CONTINUOUS SPAN END SUPPORT END SUPPORT SPLICE 0.5 "L" "L" CLEARSPAN 6" MIN. 2" "SL" STIRRUPS - SEE SCHEDULE "SM""SR" 2" 6" MIN. 0.2 "L"0.2 " L" B2 B3 T2 0.2 "L" TYP. NOTE 1 0.2 "L" NOTE 1 4'-0" MINIMUM (TYPICAL) DEVELOPMENT LENGTH OR TYP. NOTE 1 CLR. 2" B1STIRRUPS (TYPICAL) B1 T1 T1 T3 T6T3T6 "ℓ""a""c""b"POINT 0.1 "ℓ" INFLECTION POINT 0.1 "ℓ" INFLECTION T5 SINGLE SPAN TYPE 1A STIRRUP (INTERIOR BEAM) "W""D"SEE NOTE 3 TYPE 1B STIRRUP (INTERIOR BEAM) "W""D"TYPE 1C STIRRUP (SPANDREL BEAM) "W""D"TYPE 1D STIRRUP (BEAM WITHOUT SLAB) "W""D"TYPE 1E STIRRUP (INTERIOR BEAM) "W""D"BEAM TOP BARS KEEP MIN. TWO BARS IN STIRRUP CORNERS, ADD EXTRA IN SLAB AT SIDE. TYPE 2A STIRRUP (INTERIOR BEAM) "W""D"SEE NOTE 3 0" TYPE 2B STIRRUP (INTERIOR BEAM) "W""D"0" TYPE 2C STIRRUP SPANDREL BEAM) "W""D"0" TYPE 2D STIRRUP (BEAM WITHOUT SLAB) "W""D"0" "SL" "SM" "SR""SL" "SM" "SR""SC" LEFT CANTILEVER (LC)RIGHT END (RE) STIRRUPS AT OPPOSITE HAND MAX. 1'-0" MAX. 1'-0" TYPE 3A STIRRUP (INTERIOR BEAM) "W""D"SEE NOTE 3 0" TYP.TYPE 3B STIRRUP (INTERIOR BEAM) "W""D"0" TYP.TYPE 3C STIRRUP SPANDREL BEAM) "W""D"0" TYP.TYPE 3D STIRRUP (BEAM WITHOUT SLAB) "W""D"0" TYP.SLAB REINFORCING NOT SHOWN FOR CLARITY. POST-TENSIONING NOT SHOWN FOR CLARITY. * COORDINATE REINFORCING CLEARANCES WITH STRUCTURAL NOTES (TYP.) BEAM TOP AND BOTTOM STEEL GIRDER TOP AND BOTTOM STEEL GIRDER STIRRUP - SEE SCHEDULE FOR STIRRUP TYPE BEAM STIRRUP*SCHEDULE NOTES: 1. CLASS "B" LAP SPLICE - SEE STRUCTURAL NOTES. 2. WHICHEVER IS THE GREATER OF THE TWO VALUES. 3. PROVIDE ACI STANDARD 90° & 135° HOOKS AS DEPICTED. 4. FACE BARS NOT SHOWN IN ELEVATION FOR CLARITY. FACE BARS TO BE CONTINUOUS - PROVIDE CLASS "B" LAP SPLICES. 5. CONTRACTOR HAS THE OPTION OF DETAILING ONE LONG BAR WHERE BARS THE SAME SIZE AND SAME NUMBER ARE LAPPED WITH A CLASS "B" LAP SPLICE. 6. SUPPORT BARS NOT SHOWN. PROVIDE AS REQUIRED. 7.REINFORCING SCHEDULED WITH AN "L" OR "R" INDICATES REINFORCING PLACED AT LEFT OR RIGHT ENDS OF SPAN RESPECTIVELY. 8. BARS AT INTERIOR SUPPORTS ARE SCHEDULED WITH THE SPAN TO THE LEFT OF THE SUPPORT. BEAM SCHEDULE ABBREVIATION LIST DESCRIPTIONTYPE LE I RE S LC RC SL SM SR SC LEFT END - START BEAM INTERIOR BEAM RIGHT END - END BEAM SINGLE SPAN BEAM LEFT CANTILEVER AND NEXT SPAN RIGHT CANTILEVER AND BACK SPAN STIRRUPS - LEFT STIRRUPS - MIDDLE STIRRUPS - RIGHT STIRRUPS - CANTILEVER LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:30 PMS7−01 08.14.18P.T. BEAM DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 1 POST-TENSIONED BEAM ELEVATIONS 4 TYPICAL STIRRUP DETAILS 2 TYPICAL REINFORCEMENT LAYERING DIAGRAM3NOT USED Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 DSUPPORT SUPPORT SUPPORT 1'-0"LAP SPLICE CLASS "B" < 1.0 "L3" X < 0.25 "L" < 0.33 "L1" OR "L2" "T2" "T1", "T3", OR "T4" LAP SPLICE CLASS "B"1'-0""B2" "B2" OR "B5" "B2" OR "B6" SUPPORT SUPPORT SUPPORT 1'-0"≥ 1.0 "L3" X ≥ 0.25 "L" ≥ 0.33 "L1" OR "L2" "T2" "T1", "T3", OR "T4"1'-0""B8", "B9", OR "B10""B8", "B9", OR "B10" LAP SPLICE CLASS "B" LAP SPLICE CLASS "B" SUPPORT SUPPORT 1'-0""T6" OR "T7" "T5", "T6", OR "T7" LAP SPLICE CLASS "B"BEAM WIDTHSCHEDULEDFACE OF COLUMN SEE SCHEDULE TYP. SPACING -REINF. PER SCHEDULE 4" MIN.6" MIN.ADDL STIRRUPS TO MATCH BEAM STIRRUPS EACH SIDE OF SLEEVE EDGE OF BEAM SLEEVE NOTES: 1. MAINTAIN CONCRETE COVER REQUIREMENTS AT SLEEVES 2. PLACE VERTICAL BEAM PENETRATIONS ONLY AT LOCATIONS SHOWN ON STRUCTURAL DWGS. ALL OTHER VERTICAL PENETRATIONS MUST BE VERIFIED WITH STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION PLAN VIEW ADDL 4#7x5'-0"6" MIN.2 ADDL STIRRUPS @ 2" EACH SIDE OF OPENING NOTE: OPENINGS SHALL BE PLACED IN MIDDLE 1/3 SPAN OR CONSULT W/ ENGINEER6" MIN.T/SLAB B/SLAB B/BEAM 8" DIA. OPENING (MAX.) FACE BAR CRITERIA CONCRETE COVER Cc (IN.) MAX. BAR SPACING (IN.) 0 ≤ Cc ≤ 1 3/16 12 1 3/16 ≤ Cc ≤ 2 10 2 ≤ Cc ≤ 2 1/2 2 1/2 ≤ Cc ≤ 2 3/4 9 2 3/4 ≤ Cc ≤ 3 1/2 8 3 1/2 ≤ Cc ≤ 4 1/2 6 4 1/2 ≤ Cc ≤ 4 13/16 4 3 NOTES: 1. PROVIDE FACE BARS BY CRITERIA SHOWN FOR ALL BEAMS AND GIRDERS DEEPER THAN 36" UNLESS GIVEN OTHERWISE IN SCHEDULES OR DETAILS. 2. LAP FACE BARS WITH CLASS B LAP AT SPLICES. 3. SPACE FACE BARS EVENLY EACH FACE BETWEEN TOP AND BOTTOM REINFORCEMENT. 4. PROVIDE #5 BARS IF SIZE OF BAR IS NOT SPECIFIED. T/ BEAM OR GIRDER OR BEAM DEPTH "D"SCHEDULED GIRDEREQEQEQEQBEAM WIDTH "W" SCHEDULED GIRDER OR SCHEDULED OR DETAILED TOP REINFORCEMENT FACE BARS SEE CRITERIA ABOVE SCHEDULED OR DETAILED BOTTOM REINFORCEMENT FACE OF BEAM FACE BAR Cc SCHEDULED OR DETAILED STIRRUPS STIRRUP "a" PER SCHEDULE BEAM WIDTH BEAM1#5 CONT. ADDITIONAL T&B WHEN "a" EXCEEDS 3" 2#5 CONT. ADDITIONAL T&B WHEN "a" EXCEEDS 12" #3 U-BAR SPACED TO MATCH BEAM STIRRUPS WHEN "a" EXCEEDS 3" FACE BARS TO MATCH SCHEDULED FACE BARS WHEN "a" EXCEEDS 3". WIDEN AT OPENINGS OR EDGE OF SLAB VARIATIONS "a""c"NOTES: 1. SEE 1/S7-01 FOR ADDITIONAL INFORMATION 2. SEE SCHEDULE FOR TENDON C.G.S. CONCRETE BEAMPOST-TENSIONED BEAM 3" 2" 2" 3" CONSTRUCTION JOINT NOTES: 1. ADDITIONAL STIRRUPS TO MATCH SCHEDULED BEAM STIRRUPS EA SIDE OF JOINT. 2. TOP & BOTTOM REINFORCING PER BEAM SCEDULE, CONTINUOUS THRU JOINT. 3. ADD #5X4'-0" FACE BARS EQUALLY SPACED ALONG EA. FACE OF BEAM. USE: 2#5 FOR D < 24" 3#5 FOR 24" < D < 36" 4#5 FOR 36" < D < 48" VERIFY WITH E.O.R. FOR BEAMS > 48" VERIFY WITH E.O.R. 4. #4 BARS FULL WIDTH OF BEAM WITH 90° HOOKS EA END, SET IMMEDIATELY BEHIND P.T. ANCHORS. 5. ROUGHEN SURFACE OR PROVIDE EXPANDED METAL LATH EMBEDDED AT BULKHEAD. 6. CONSTRUCTION JOINT LOCATION. SEE STRUCTURAL SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS. SEE STRUCTURAL NOTES FOR RULES REGARDING LOCATIONS AND ADDITION TO THE FOLLOWING: a. SET CONSTRUCTION JOINTS SO TENDON ANCHORS DO NOT INTERFERE WITH P.T. BEAM MILD REINFORCEMENT. REQUIRED BEAM REINFORCEMENT CONCRETE COVER MUST BE MAINTAINED. b. MAINTAIN MINIMUM 4" EDGE DISTANCE FROM C.L. OF ANY P.T. ANCHORS TO EDGE OF CONCRETE (ASSUMING NO CONFLICTS PER ITEM a.) c. NOT SATISFYING ITEMS a. AND b. WILL REQUIRE JOGGING THE CONSTRUCTION JOINT IN BEAM TO SHIFT JOINT FURTHER INTO BEAM SPAN. 7. C.G. OF P.T. ANCHORS TO ALWAYS MATCH THEORETICAL HEIGHT OF TENDONS AT LOCATION OF ALL CONSTRUCTION JOINTS AS CALCULATED BY THE P.T. VENDOR. NOTE 2 NOTE 7 NOTE 1 NOTE 4 NOTE 5 NOTE 3 NOTE 6 3"4'-0"3'-0"(3) ADDITIONAL #5 TOP BARS @ 6" EACH SIDE INTERIOR BEAM P.T. BEAM LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:34 PMS7−02 08.14.18P.T. BEAM DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851TYPICAL CONCRETE BEAM STEP DETAILSMS) 2 TYP. VERTICAL BEAM PENETRATION DETAIL 3 TYPICAL HORIZONTAL BEAM PENETRATION 6 TYPICAL CONCRETE GIRDER AND BEAM FACE BARS CRITERIA 4 TYPICAL BEAM WIDENING DETAIL 5 TYPICAL ANCHORAGE OF TENDONS IN ADJACENT BEAM 8 TYPICAL CONSTRUCTION JOINT@ P.T. BEAM 9 TYPICAL DETAIL AT P.T. BEAM TERMINATION Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION 7 NOT USED 08/14/18 DASHED LINE INDICATES LIMIT OF BEAMS AS DETAILED SEE BEAM SCHEDULE SEE BEAM SCHEDULE SCHEDULESEE BEAMSEE BEAM SCHEDULE FOR REINFORCEMENT AND POST TENSIONING DASHED LINE INDICATES LIMIT OF BEAMS AS DETAILED SEE BEAM SCHEDULE SEE BEAM SCHEDULE SCHEDULESEE BEAMSEE BEAM SCHEDULE FOR REINFORCEMENT AND POST TENSIONING T/RAMP VARIES LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:37 PMS7−03 08.14.18P.T. BEAM DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_0851SECTION Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 2 SECTION 08/14/18 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:48 PMS7−05 08.14.18P.T. BEAM SCHEDULE401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 POST-TENSIONED BEAM SCHEDULE BEAM MARK "W" "D1" "D2" BEAM TYPE EFFECTIVE PRESTRESS FORCE DISTANCE FROM BOTTOM OF BEAM TO CENTERLINE OF TENDON (INCHES) TOP BARS BOTTOM BARS FACE BARS (EA FACE) BEAM MARK STIRRUPS BEAM REMARKS "a" "b" "c" "d" "e" "T1" "T2" "T3" "T4" "T5" "T6" "T7" "B1" "B2""B3" "B4" "B5" "B6" "B7" "B8" "B9" "B10" SIZE TYPE (SPACING SHOWN IN INCHES) "SL" "SM" "SR" "SC" PB001 18" 23" 0" S 405 kip 16" 3 1/2" 16" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB001 #4 1C 15 15 15 -- PB002 24" 23" 0" S 486 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB002 #4 1C 15 15 15 -- PB003 18" 23" 0" S 324 kip 16" 3 1/2" 16" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB003 #4 1C 15 15 15 -- PB004 36" 23" 0" RC 459 kip 11 3/4" 11" 0" 19 1/2" 12 1/4" 4#7 4#5 - 5#9 - - - 4#5 4#7 - - 4#5 - - - - - - PB004 #4 2C 15 15 15 6 - PB005 40" 23" 0" S 459 kip 11 3/4" 11" 11 3/4" 0" 0" 4#7 4#5 - - -- - 4#5 4#7 - - - - - - - - - PB005 #4 2C 15 15 15 -- PB006 48" 23" 0" S 783 kip 14" 3 1/2" 14" 0" 0" 6#7 4#5 - - - - - 4#5 6#7 - - - - - - - - - PB006 #4 2C 12 12 12 -- PB007 18" 23" 0" LE 0 kip 12 3/4" 5" 19 1/2" 0" 0" - - - - 3#7 6#7 - - - - - - - 3#7 6#9 - - - PB007 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; HALF OF TENDONS TO BE ANCHORED AT LEFT SUPPORT; REMAINING TO BE ANCHORED AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); LEFT END OF HALF OF T6 BARS AND B8 BARS TO HOOK AT STEP IN BEAM WIDTH; USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB008 34" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 5#9 - - - - -- - - - 5#9 - - PB008 #4 2C 15 15 15 - HOOK (1)-T6 BAR AT RIGHT SUPPORT PB009 30" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 5#9 - - - - -- - - - 5#9 - - PB009 #4 2C 15 15 15 -- PB010 30" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 5#9 - - - - -- - - - 5#9 - - PB010 #4 2C 15 15 15 -- PB011 30" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#7 - - - - - - - - - 6#9 - - PB011 #4 2C 15 15 15 - LEFT END OF (1)-T6 BAR AND (1)-B9 BAR TO HOOK AT RIGHT SUPPORT; HALF OF T6 BARS AND B9 BARS TO HOOK AT STEP IN BEAM WIDTH OF ADJACENT SPAN PB012 34" 23" 0" RE 0 kip 12 3/4" 3 1/2" 19 1/2" 0" 0" - - - - 3#7 - - - - - - - - 3#7 - - - - PB012 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; TERMINATE HALF OF TENDONS AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB013 40" 23" 0" LE 162 kip 12 1/2" 5" 19 1/2" 0" 0" - - - - 5#9 6#9 - - - - - - - 5#9 6#9 - - - PB013 #4 2C 15 15 15 -- PB014 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB014 #4 2C 15 15 15 -- PB015 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB015 #4 2C 15 15 15 -- PB016 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB016 #4 2C 15 15 15 -- PB017 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB017 #4 2C 15 15 15 -- PB018 40" 23" 0" I 162 kip 0" 10" 19 1/2" 0" 0" - - - - - 6#9 - - - - - -- - - 6#9 - - PB018 #4 2C 15 15 15 -- PB019 40" 23" 0" RE 162 kip 12 1/2" 10" 0" 0" 0" - - - - 5#9 - - - - - -- - 5#9 - - - - PB019 #4 2C 15 15 15 -- PB020 44" 23" 0" LC 162 kip 0" 10" 19 1/2" 16" 11 3/4" - - - - - 6#9 6#9 - - - - - - 6#9 6#9 - - - PB020 #4 2C 15 15 15 4 - PB021 44" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB021 #4 2C 15 15 15 -- PB022 44" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB022 #4 2C 15 15 15 -- PB023 44" 23" 0" I 162 kip 0" 6" 19 1/2" 0" 0" - - - - - 6#9 - - - - - - -- - 6#9 - - PB023 #4 2C 15 15 15 - EXTEND T6 BARS TO HOOK AT END OF CANTILEVER PB024 44" 23" 0" RC 513 kip 0" 19" 0" 19 1/2" 12" - - - - - - - - - - - -- - - - 6#9 #5@4" PB024 #4 2C 4 4 4 4 - PB025 32" 23" 0" LE 189 kip 13" 3 1/2" 19 1/2" 0" 0" - - - - 5#9 7#9 - - - - - - - 5#9 7#9 - - - PB025 #4 2C 15 15 15 - LEFT END OF (2)-T6 BARS AND (2)-B8 BARS TO HOOK AT STEP IN BEAM WIDTH PB026 48" 23" 0" I 189 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB026 #4 2C 15 15 15 -- PB027 48" 23" 0" I 189 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB027 #4 2C 15 15 15 -- PB028 48" 23" 0" RC 189 kip 0" 3 1/2" 0" 15 1/2" 11 3/4" - - - - -- 6#9 - - - - - - - - - 6#9 - PB028 #4 2C 15 15 15 4 - PB029 18" 23" 0" S 243 kip 14" 3 1/2" 14" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB029 #4 1C 15 15 15 -- PB030 18" 23" 0" S 324 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB030 #4 1C 9 9 9 - EXTEND RIGHT END T1 & B1 BARS A DEVELOPMENT LENGTH STRAIGHT INTO SUPPORT PB031 48" 23" 0" LE 783 kip 14" 3 1/2" 19 1/2" 0" 0" 6#7 4#5 6#9 - - - - 4#5 6#7 - 6#5 - - - - - - - PB031 #4 2C 12 12 12 - TENDON FORCE OF 513 KIPS TO BE ANCHORED AT CENTROID OF BEAM AT RIGHT SUPPORT; (4)-T3 BARS & (4)-B4 BARS TO HOOK AT RIGHT SUPPORT PB032 18" 23" 0" I 270 kip 0" 3 1/2" 19 1/2" 0" 0" - 2#5 2#9 - - - -- 3#7 - 2#5 - - - - - - - PB032 #4 1C 9 9 9 -- PB033 18" 23" 0" RE 270 kip 15 1/2" 3 1/2" 0" 0" 0" 2#9 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB033 #4 1C 9 9 9 - EXTEND T1 & B1 BARS A DEVELOPMENT LENGTH STRAIGHT INTO RIGHT SUPPORT PB101 18" 23" 0" S 351 kip 16" 3 1/2" 16" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB101 #4 1C 15 15 15 -- PB102 24" 23" 0" S 459 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB102 #4 1C 15 15 15 -- PB103 36" 23" 0" S 621 kip 14 1/2" 3 1/2" 14 1/2" 0" 0" 5#7 4#5 - - - - - 4#5 5#7 - - - - - - - - - PB103 #4 2C 15 15 15 -- PB104 36" 23" 0" RC 459 kip 11 3/4" 11" 0" 19 1/2" 12 1/4" 4#7 4#5 - 5#9 - - - 4#5 4#7 - - 4#5 - - - - - - PB104 #4 2C 15 15 15 6 - PB105 40" 23" 0" S 459 kip 11 3/4" 11" 11 3/4" 0" 0" 4#7 4#5 - - -- - 4#5 4#7 - - - - - - - - - PB105 #4 2C 15 15 15 -- PB106 48" 23" 0" S 729 kip 14" 3 1/2" 14" 0" 0" 6#7 4#5 - - - - - 4#5 6#7 - - - - - - - - - PB106 #4 2C 12 12 12 -- PB107 18" 23" 0" LE 0 kip 11 1/2" 3 1/2" 19 1/2" 0" 0" - - - - 3#7 6#7 - - - - - - - 3#7 6#9 - - - PB107 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; HALF OF TENDONS TO BE ANCHORED AT LEFT SUPPORT; REMAINING TO BE ANCHORED AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); LEFT END OF HALF OF T6 BARS AND B8 BARS TO HOOK AT STEP IN BEAM WIDTH; USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB108 34" 23" 0" I 0 kip 0" 10" 19 1/2" 0" 0" - - - - - 5#9 - - - - - - - -- 5#9 - - PB108 #4 2C 15 15 15 - HOOK (1)-T6 BAR AT RIGHT SUPPORT PB109 30" 23" 0" I 0 kip 0" 8" 19 1/2" 0" 0" - - - - - 5#9 - - - - - - - - -5#9 - - PB109 #4 2C 15 15 15 -- PB110 30" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 5#9 - - - - -- - - - 5#9 - - PB110 #4 2C 15 15 15 -- PB111 30" 23" 0" I 0 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#7 - - - - - - - - - 6#9 - - PB111 #4 2C 15 15 15 - LEFT END OF (1)-T6 BAR AND (1)-B9 BAR TO HOOK AT RIGHT SUPPORT; HALF OF T6 BARS AND B9 BARS TO HOOK AT STEP IN BEAM WIDTH OF ADJACENT SPAN PB112 34" 23" 0" RE 0 kip 12 3/4" 3 1/2" 19 1/2" 0" 0" - - - - 3#7 - - - - - - - - 3#7 - - - - PB112 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; TERMINATE HALF OF TENDONS AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB113 40" 23" 0" LE 162 kip 12 1/2" 5" 19 1/2" 0" 0" - - - - 5#9 6#9 - - - - - - - 5#9 6#9 - - - PB113 #4 2C 15 15 15 -- PB114 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB114 #4 2C 15 15 15 -- PB115 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB115 #4 2C 15 15 15 -- PB116 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB116 #4 2C 15 15 15 -- PB117 40" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB117 #4 2C 15 15 15 -- PB118 40" 23" 0" I 162 kip 0" 10" 19 1/2" 0" 0" - - - - - 6#9 - - - - - -- - - 6#9 - - PB118 #4 2C 15 15 15 -- PB119 40" 23" 0" RE 162 kip 12 1/2" 10" 0" 0" 0" - - - - 5#9 - - - - - -- - 5#9 - - - - PB119 #4 2C 15 15 15 -- PB120 44" 23" 0" LC 162 kip 0" 10" 19 1/2" 16" 11 3/4" - - - - - 6#9 6#9 - - - - - - 6#9 6#9 - - - PB120 #4 2C 15 15 15 4 - PB121 44" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB121 #4 2C 15 15 15 -- PB122 44" 23" 0" I 162 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB122 #4 2C 15 15 15 -- PB123 44" 23" 0" I 162 kip 0" 6" 19 1/2" 0" 0" - - - - - 6#9 - - - - - - -- - 6#9 - - PB123 #4 2C 15 15 15 - EXTEND T6 BARS TO HOOK AT END OF CANTILEVER PB124 44" 23" 0" RC 513 kip 0" 19" 0" 19 1/2" 11 1/2" - - - - - - - -- - - - - - - - 6#9 #5@4" PB124 #4 2C 4 4 4 4 - PB125 32" 23" 0" LE 189 kip 13" 3 1/2" 19 1/2" 0" 0" - - - - 5#9 7#9 - - - - - - - 5#9 7#9 - - - PB125 #4 2C 15 15 15 - LEFT END OF (2)-T6 BARS AND (2)-B8 BARS TO HOOK AT STEP IN BEAM WIDTH PB126 48" 23" 0" I 189 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB126 #4 2C 15 15 15 -- PB127 48" 23" 0" I 189 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 6#9 - - -- - - - - - 6#9 - - PB127 #4 2C 15 15 15 -- PB128 48" 23" 0" RC 189 kip 0" 3 1/2" 0" 15 1/2" 11 3/4" - - - - -- 6#9 - - - - - - - - - 6#9 - PB128 #4 2C 15 15 15 4 - PB129 60" 23" 0" S 756 kip 12 3/4" 3 1/2" 12 3/4" 0" 0" 8#7 6#5 - - - - - 6#5 8#7 - - - - - - - - - PB129 #4 3C 15 15 15 -- PB130 18" 23" 0" S 243 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB130 #4 1C 9 9 9 - EXTEND RIGHT END T1 & B1 BARS A DEVELOPMENT LENGTH STRAIGHT INTO SUPPORT PB131 48" 23" 0" LE 729 kip 14" 3 1/2" 19 1/2" 0" 0" 6#7 4#5 6#9 - - - - 4#5 6#7 - 6#5 - - - - - - - PB131 #4 2C 12 12 12 - TENDON FORCE OF 513 KIPS TO BE ANCHORED AT CENTROID OF BEAM AT RIGHT SUPPORT; (2)-T3 BARS & (2)-B4 BARS TO HOOK AT RIGHT SUPPORT PB132 30" 23" 0" I 216 kip 0" 8" 19 1/2" 0" 0" - 4#5 4#7 - - - - - 4#7 - 4#5 - - - - - - - PB132 #4 1C 9 9 9 -- PB133 30" 23" 0" RE 216 kip 14" 3 1/2" 0" 0" 0" 4#7 4#5 - - - - - 4#5 4#7 - - - - - - - - - PB133 #4 1C 9 9 9 -- PB134 18" 23" 0" LE 108 kip 13 3/4" 5" 19 1/2" 0" 0" 3#7 2#5 3#7 - - - - 2#5 3#7 - 2#5 - - - - - - - PB134 #4 1C 15 15 15 -- PB135 18" 23" 0" RE 108 kip 13 3/4" 3 1/2" 0" 0" 0" 3#7 2#5 - - - -- 2#5 3#7 - - - - - - - - - PB135 #4 1C 15 15 15 -- PB136 18" 23" 0" RC 81 kip 14 3/4" 3 1/2" 0" 14 3/4" 14 3/4" 3#7 2#5 - 3#7 - - - 2#5 3#7 - - 3#5 - - - - - - PB136 #4 1C 15 15 15 4 - PB137 18" 23" 0" S 108 kip 14 1/2" 3 1/2" 14 1/2" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB137 #4 1C 15 15 15 -- PB138 18" 23" 0" S 162 kip 15 3/4" 3 1/2" 15 3/4" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB138 #4 1C 15 15 15 -- PB139 24" 23" 0" LE 162 kip 14 1/4" 6" 19 1/2" 0" 0" 4#7 2#5 4#7 - - - - 2#5 4#7 - 2#5 - - - - - - - PB139 #4 1C 15 15 15 -- PB140 24" 23" 0" I 162 kip 0" 3 1/2" 15" 0" 0" - 2#5 4#7 - - - - - 4#7 - 2#5 - - - - - - - PB140 #4 1C 15 15 15 - EXTEND RIGHTT END OF T3 BARS TO HOOK AT FAR RIGHT SUPPORT PB141 24" 23" 0" RE 162 kip 12 1/2" 12" 0" 0" 0" - - - - - - - 2#5 4#7 - - - - - - - - - PB141 #4 1C 15 15 15 -- PB142 24" 23" 0" S 459 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB142 #4 1C 15 15 15 -- PB143 24" 23" 0" LE 135 kip 14 3/4" 3 1/2" 18" 0" 0" 4#7 2#5 4#7 - - - - 2#5 4#7 - 2#5 - - - - - - - PB143 #4 1C 15 15 15 - EXTEND RIGHT END OF T3 BARS TO HOOK AT FAR RIGHT SUPPORT PB144 24" 23" 0" RE 135 kip 12 3/4" 12" 0" 0" 0" - - - - - - - 2#5 4#7 - - - - - - - - - PB144 #4 1C 15 15 15 -- PB145 24" 23" 0" LE 135 kip 13 1/4" 3 1/2" 19 1/2" 0" 0" 4#7 2#5 4#7 - - - - 2#5 4#7 - 2#5 - - - - - - - PB145 #4 1C 15 15 15 -- PB146 24" 23" 0" RE 135 kip 13 1/4" 6" 0" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB146 #4 1C 15 15 15 -- PB147 18" 23" 0" S 324 kip 14 1/2" 3 1/2" 14 1/2" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB147 #4 1C 15 15 15 -- PB148 18" 23" 0" RC 108 kip 15" 3 1/2" 0" 14 3/4" 12" - - - - 3#7 -3#7 2#5 3#7 - - 2#5 - - - - - - PB148 #4 1C 15 15 15 4 - PB149 18" 23" 0" S 108 kip 14 3/4" 3 1/2" 14 3/4" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB149 #4 1C 15 15 15 -- PB150 40" 23" 0" RE 162 kip 12 1/2" 3 1/2" 0" 0" 0" - - - - 5#9 - - -- - - - - 5#9 - - - - PB150 #4 2C 15 15 15 -- PB151 40" 23" 0" LE 135 kip 12 1/2" 5" 19 1/2" 0" 0" - - - - 5#9 5#9 - - - - - - - 5#9 5#9 - - - PB151 #4 2C 15 15 15 -- PB152 40" 23" 0" I 135 kip 0" 3 1/2" 19 1/2" 0" 0" - - - - - 5#9 - - -- - - - - - 5#9 - - PB152 #4 2C 15 15 15 -- PB153 40" 23" 0" RE 135 kip 12 1/2" 8" 0" 0" 0" - - - - 5#9 - - - - - - -- 5#9 - - - - PB153 #4 2C 15 15 15 -- PB154 60" 23" 0" LC 189 kip 0" 3 1/2" 19 1/2" 13 1/2" 11 1/2"- - - - - 6#9 6#9 - - - - - - 6#9 6#9 - - - PB154 #4 3C 15 15 15 4 - PB155 60" 23" 0" RE 189 kip 12" 6 1/2" 0" 0" 0" - - - - 6#9 - - - - - - -- 6#9 - - - - PB155 #4 3C 15 15 15 -- PB156 44" 23" 0" LC 162 kip 0" 10" 19 1/2" 16" 11 3/4" - - - - - 6#9 6#9 - - - - - - 6#9 6#9 - - - PB156 #4 2C 15 15 15 4 - PB157 44" 23" 0" I 162 kip 0" 6" 19 1/2" 0" 0" - - - - - 6#9 - - - - - - -- - 6#9 - - PB157 #4 2C 15 15 15 -- PB158 44" 23" 0" I 162 kip 0" 6" 19 1/2" 0" 0" - - - - - 6#9 - - - - - - -- - 6#9 - - PB158 #4 2C 15 15 15 -- PB159 44" 23" 0" I 162 kip 0" 6" 19 1/2" 0" 0" - - - - - 6#9 - - - - - - -- - 6#9 - - PB159 #4 2C 15 15 15 - EXTEND T6 BARS TO HOOK AT END OF CANTILEVER Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 08/14/18 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTIONDRAWING FILEPLOTTED ONPROJECT No. 17263.00 COA No.C-3232 E:\sdl\Revit_Local_Files\1726300_401_South_Graham_SDL17_creichard@sdlal.com.rvt8/14/2018 2:16:54 PMS7−06 08.14.18P.T. BEAM SCHEDULE401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION POST-TENSIONED BEAM SCHEDULE BEAM MARK "W" "D1" "D2" BEAM TYPE EFFECTIVE PRESTRESS FORCE DISTANCE FROM BOTTOM OF BEAM TO CENTERLINE OF TENDON (INCHES) TOP BARS BOTTOM BARS FACE BARS (EA FACE) BEAM MARK STIRRUPS BEAM REMARKS "a" "b" "c" "d" "e" "T1" "T2" "T3" "T4" "T5" "T6" "T7" "B1" "B2""B3" "B4" "B5" "B6" "B7" "B8" "B9" "B10" SIZE TYPE (SPACING SHOWN IN INCHES) "SL" "SM" "SR" "SC" PB160 44" 23" 0" RC 513 kip 0" 19" 0" 19 1/2" 11 1/2" - - - - - - - -- - - - - - - - 6#9 #5@4" PB160 #4 2C 4 4 4 4 - PB161 60" 23" 0" S 432 kip 12 3/4" 3 1/2" 12 3/4" 0" 0" 8#7 6#5 - - - - - 6#5 8#7 - - - - - - - - - PB161 #4 3C 15 15 15 -- PB163 30" 23" 0" LE 378 kip 13" 3 1/2" 15" 0" 0" 5#7 4#5 5#7 - - - -4#5 5#7 - 4#5 - - - - - - - PB163 #4 2C 15 15 15 - EXTEND RIGHT END OF T3 BARS TO HOOK AT FAR RIGHT SUPPORT PB164 30" 23" 0" RE 0 kip 12 1/2" 12 1/4" 0" 0" 0" - - - - - - - 4#5 5#7 - - - - - - - - - PB164 #4 2C 15 15 15 -- PB165 40" 23" 0" LC 162 kip 0" 3 1/2" 19 1/2" 15" 12 1/2" - - - -- 6#9 6#9 - - - - - - - 6#9 - 6#9 - PB165 #4 2C 15 15 15 4 - PB166 40" 23" 0" I 162 kip 0" 10" 19 1/2" 0" 0" - - - - - 6#9 - - - - - -- - - 6#9 - - PB166 #4 2C 15 15 15 -- PB167 40" 23" 0" RE 162 kip 12 1/2" 10" 0" 0" 0" - - - - 5#9 - - - - - -- - 5#9 - - - - PB167 #4 2C 15 15 15 -- PB201 18" 23" 0" S 135 kip 15 1/2" 4" 15 1/2" 0" 0" 4#7 2#5 - - - -- 2#5 4#7 - - - - - - - - - PB201 #4 1C 15 15 15 -- PB202 18" 23" 0" LE 81 kip 15 1/4" 8" 19 1/2" 0" 0" 3#7 2#5 3#7 -- - - 2#5 3#7 - 2#5 - - - - - - - PB202 #4 1C 15 15 15 -- PB203 18" 23" 0" RE 81 kip 15 1/4" 8" 0" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB203 #4 1C 15 15 15 -- PB204 18" 23" 0" S 297 kip 14" 3 1/2" 14" 0" 0" 4#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB204 #4 1C 15 15 15 -- PB205 18" 23" 0" LE 108 kip 15 1/2" 3 1/2" 19 1/2" 0" 0" 3#7 2#5 4#7 - - - - 2#5 3#7 - 2#5 - - - - - - - PB205 #4 1C 15 15 15 -- PB206 18" 23" 0" RE 108 kip 15 1/4" 3 1/2" 0" 0" 0" 3#7 2#5 - - - -- 2#5 3#7 - - - - - - - - - PB206 #4 1C 15 15 15 -- PB207 24" 23" 0" S 513 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 4#7 2#5 - - - - - 2#5 4#9 - - - - - - - - - PB207 #4 1C 12 12 12 -- PB208 24" 23" 0" S 351 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 4#9 2#5 - - - - - 2#5 4#9 - - - - - - - - - PB208 #4 1C 12 12 12 -- PB209 24" 35" 0" S 432 kip 19 3/4" 3 1/2" 19 3/4" 0" 0" 5#7 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB209 #4 1C 18 18 18 -- PB210 18" 23" 0" S 108 kip 15 1/4" 3 1/2" 15 1/4" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 - - - - - - - - - PB210 #4 1C 15 15 15 -- PB211 18" 23" 0" S 108 kip 15" 5" 15" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 -- - - - - - - - PB211 #4 1C 15 15 15 -- PB212 18" 23" 0" S 108 kip 15" 6" 15" 0" 0" 3#7 2#5 - - - - - 2#5 3#7 -- - - - - - - - PB212 #4 1C 15 15 15 -- PB213 24" 23" 0" LE 0 kip 12 1/2" 3 1/2" 19 1/2" 0" 0" - - - - 3#7 6#7 - - - - - - - 3#7 6#9 - - - PB213 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; HALF OF TENDONS TO BE ANCHORED AT LEFT SUPPORT; REMAINING TO BE ANCHORED AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); LEFT END OF HALF OF T6 BARS AND B8 BARS TO HOOK AT STEP IN BEAM WIDTH; USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB214 40" 23" 0" I 0 kip 0" 10" 19 1/2" 0" 0" - - - - - 5#9 - - - - - - - -- 5#9 - - PB214 #4 2C 15 15 15 - HOOK (1)-T6 BAR AT RIGHT SUPPORT PB215 30" 23" 0" I 0 kip 0" 8" 19 1/2" 0" 0" - - - - - 5#9 - - - - - - - - -5#9 - - PB215 #4 2C 15 15 15 -- PB216 30" 23" 0" I 0 kip 0" 8" 19 1/2" 0" 0" - - - - - 5#9 - - - - - - - - -5#9 - - PB216 #4 2C 15 15 15 -- PB217 30" 23" 0" I 0 kip 0" 10" 19 1/2" 0" 0" - - - - - 6#7 - - - - - - - - - 6#9 - - PB217 #4 2C 15 15 15 - LEFT END OF (1)-T6 BAR AND (1)-B9 BAR TO HOOK AT RIGHT SUPPORT; HALF OF T6 BARS AND B9 BARS TO HOOK AT STEP IN BEAM WIDTH OF ADJACENT SPAN; SEE 1/S7-02 FOR STEP IN BEAM DEPTH AT RIGHT SUPPORT PB218 40" 35" 0" RE 0 kip 18 3/4" 5" 19 1/2" 0" 0" - - - - 3#7 - - - - - - - - 3#7 - - - - PB218 #4 2C 15 15 15 - SEE PLAN FOR STEP IN BEAM WIDTH; TERMINATE HALF OF TENDONS AT STEP IN BEAM WIDTH (MID-DEPTH OF BEAM); USE TYPE 1C #4 STIRRUPS @ 12" WITHIN NARROWER BEAM WIDTH PB219 36" 35" 0" RC 378 kip 18 1/4" 17 1/2" 0" 31 1/2" 18 1/2" 5#7 4#5 - 5#9 - - - 4#5 5#7 - - 4#5 - - - - - - PB219 #4 2C 15 15 15 6 - PB220 40" 35" 0" S 378 kip 18 1/4" 17 1/2" 18 1/4" 0" 0" 5#7 4#5 - - - - - 4#5 5#7 - - - - - - - - - PB220 #4 2C 15 15 15 -- PB221 18" 23" 0" S 324 kip 15 3/4" 3 1/2" 15 3/4" 0" 0" 3#9 2#5 - - - - - 2#5 4#7 - - - - - - - - - PB221 #4 1C 15 15 15 -- PB222 36" 20" 0" LE 351 kip 11 1/4" 3 1/2" 16 1/2" 0" 0" 4#7 4#5 4#7 - - - - 4#5 4#7 - 4#5 - - - - - - - PB222 #4 2C 15 15 15 -- PB223 36" 20" 0" RE 351 kip 11 1/4" 3 1/2" 0" 0" 0" 4#7 4#5 - - - -- 4#5 4#7 - - - - - - - - - PB223 #4 2C 15 15 15 -- PB224 36" 20" 0" LE 216 kip 11 1/4" 3 1/2" 16 1/2" 0" 0" 4#7 4#5 4#7 - - - - 4#5 4#7 - 4#5 - - - - - - - PB224 #4 2C 15 15 15 - EXTEND T3 BARS TO HOOK AT FAR RIGHT SUPPORT PB225 36" 20" 0" RE 216 kip 11 1/4" 9 1/2" 0" 0" 0" - - - - - - - 4#5 4#7 - - - - - - - - - PB225 #4 2C 15 15 15 -- PB226 18" 23" 0" LE 162 kip 15 3/4" 3 1/2" 19 1/2" 0" 0" 3#7 2#5 3#9 - - - - 2#5 3#7 - 2#5 - - - - - - - PB226 #4 1C 15 15 15 -- PB227 18" 23" 0" RE 162 kip 15 1/2" 3 1/2" 0" 0" 0" 3#7 2#5 - - - -- 2#5 3#7 - - - - - - - - - PB227 #4 1C 15 15 15 -- 08/14/18 DRAWING NUMBER SHEET NUMBER DRAWING SCALE DRAWING NUMBER SHEET NUMBER AREA TO BE ENLARGED }ENLARGED AREA DRAWING PLAN NORTH TRUE OR MAGNETIC NORTH INDICATES GENERAL REGION WITH REVISIONS REVISION NUMBER DRAWING NUMBER SHEET NUMBER }SECTION DRAWING DRAWING CALLOUT ENLARGED CALLOUT SECTION CALLOUT PLAN & TRUE NORTH REVISION CLOUD REVISION TRIANGLE SCALE: 1 X1 1 X1 1 X1 DRAWING TITLE 1/8" = 1'-0" 1 N GRAPHICAL STANDARD AAV AUTOMATIC AIR VENT AC ABOVE CEILING AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ARCH ARCHITECT B BOILER BD BALANCING DAMPER BOS BOTTOM OF STRUCTURE CAP CAPACITY CD CEILING DIFFUSER CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CHW CHILLED WATER CHWP CHILLED WATER PUMP CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CLG CEILING COMP COMPRESSOR CONC CONCRETE COP COEFFICIENT OF PERFORMANCE CT COOLING TOWER CU CONDENSING UNIT CW COLD WATER CWP CONDENSER WATER PUMP CWR ONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY D DRAIN dB DECIBLE DB DRY BULB DN DOWN DIA DIAMETER EAT ENTERING AIR TEMPERATURE EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EH ELECTRIC HEATER ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EWH ELECTRIC WALL HEATER EWT ENTERING WATER TEMPERATURE °F DEGREE FAHRENHEIT F FAN FCU FAN COIL UNIT FD FIRE DAMPER FD FLOOR DRAIN FOD FACE OPERATED DAMPER FPB FAN POWERED BOX FSD FIRE SMOKE DAMPER FT FEET G GAS GPM GALLONS PER MINUTE GPR GAS PRESSURE REGULATOR GUH GAS UNIT HEATER H HOOD, HEATER HA HEAT OF ABSORPTION HC HEATING CAPACITY HD HEAD HD HUB DRAIN HE HEAT EXCHANGER HP HORSEPOWER HP HEAT PUMP HR HEAT OF REJECTION HW HOT WATER HWP HOT WATER PUMP HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER KW KILOWATT LAT LEAVING AIR TEMPERATURE LBS POUNDS (WEIGHT) LWT LEAVING WATER TEMPERATURE MA MAKEUP AIR MAU MAKEUP AIR UNIT MAX MAXIMUM MBH THOUSAND BTUH MIN MINIMUM MOD MOTOR OPERATED DAMPER NC NOISE CONTROL NOM NOMINAL NTS NOT TO SCALE OA OUTSIDE AIR OAU OUTSIDE AIR UNIT OF OVERFLOW PCHW PRIMARY CHILLED WATER PCHWP PRIMARY CHILLED WATER PUMP PCHWS PRIMARY CHILLED WATER SUPPLY PCHWR PRIMARY CHILLED WATER RETURN PD PRESSURE DROP PIU POWERED INDUCTION UNIT PRV PRESSURE REDUCING VALVE PS PRESSURE SENSOR PTAC PACKAGED TERMINAL AIR CONDITIONER RA RETURN AIR RAG RETURN AIR GRILLE RAR RETURN AIR REGISTER RLD REFRIGERANT LEAK DETECTOR RPBP RED. PRESS. BACKFLOW PREVENT RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR SAR SUPPLY AIR REGISTER SC SENSIBLE CAPACITY SCU WATER COOLED PACKAGED UNIT SCHW SECONDARY CHILLED WATER SCHWP SECONDARY CHILLED WATER PUMP SCHWS SECONDARY CHILLED WATER SUPPLY SCHWR SECONDARY CHILLED WATER RETURN SD SMOKE DAMPER, SPLITTER DAMPER SEER SEASONAL ENERGY EFFICIENCY RATIO SP STATIC PRESSURE T THERMOSTAT TC TOTAL CAPACITY TE TOILET EXHAUST TOS TOP OF STRUCTURE TS TEMPERATURE SENSOR TSP TOTAL STATIC PRESSURE TYP TYPICAL UC UNDERCUT (DOOR) UH UNIT HEATER V VOLTAGE VAV VARIABLE AIR VOLUME UNIT VD VOLUME DAMPER VEL VELOCITY VFD VARIABLE FREQUENCY DRIVE W WATTS WB WET BULB WC WATER COLUMN WG WATER GAUGE WSHP WATER SOURCE HEAT PUMP ZD ZONE DAMPER ABBREVIATIONS T FD MOD H D R SD FSD CO2 SP LOUVER TAG RETURN AIR GRILLE TAG RETURN /EXHAUST AIR REGISTER TAG SUPPLY AIR SLOT TAG SUPPLY AIR DIFFUSER TAG AV MAV AS MV AV FS TS PS GV B B DFS M PIPE FITTED THERMOSTAT PRESSURE GAUGE BUTTERFLY VALVE BALANCING VALVE, >2" BALANCING VALVE, <2" SHUT-OFF VALVE STRAINER TRIPLE DUTY VALVE MOTORIZED 3-WAY VALVE AIR SEPARATOR PLUG VALVE POINT OF NEW/EXISTING CONNECTION PRESSURE REDUCING VALVE PRESSURE CONTROL VALVE BALL VALVE GLOBE VALVE CHECK VALVE RELIEF OR SAFETY VALVE MANUAL AIR VENT AUTOMATIC AIR VENT FLOW SWITCH TEMPERATURE SENSOR PRESSURE SENSOR PRESSURE TEST PORT FLEXIBLE CONNECTION AUTOMATIC FLOW CONTROL VALVE UNION PUMP DIFFERENTIAL PRESSURE SWITCH GAS COCK P/T PS TS TEMPERATURE SENSOR PRESSURE SENSOR PRESS./TEMP. TEST PORT (PETE'S PLUG) FLEXIBLE PIPE CONNECTION THERMOMETER WITH PIPE WELL PRESSURE GAUGE BALL VALVE BUTTERFLY VALVE STRAINER WITH DRAIN KIT TRIPLE DUTY VALVE MOTORIZED 3-WAY VALVE MOTORIZED 2-WAY VALVE AUTOMATIC FLOW CONTROL VALVE AUTOMATIC AIR VENT MANUAL AIR VENT UNION PUMP FLEXIBLE HOSE KIT AUTOMATIC BUTTERFLY VALVE A NN A NN LEGEND MARK FACE SIZE LL MARK AIRFLOW, CFM LENGTH NECK SIZE NN A BB MARK FREE AREA SUPPLY AIR REGISTER RETURN AIR GRILLE EXHAUST REGISTER LINEAR SLOT DIFFUSER SIDEWALL SUPPLY REGISTER SIDEWALL RETURN AIR REGISTER MOTOR OPERATED DAMPER FIRE DAMPER BALANCING DAMPER FIRE/SMOKE DAMPER THERMOSTAT HUMIDITY SENSOR CARBON DIOXIDE SENSOR SMOKE DETECTOR POINT OF NEW/EXISTING CONNECTION STATIC PRESSURE SENSOR FLEXIBLE DUCTWORK FLEXIBLE CONNECTION RISE IN DUCTWORK ELEVATION DROP IN DUCTWORK ELEVATION LINED DUCTWORK NEW DUCTWORK (BOLD) EXISTING DUCTWORK (SCREENED) EXISTING TO BE REMOVED (HATCHED) MARK AIRFLOW, CFM NECK SIZE MARK AIRFLOW, CFM NECK SIZENN A BB A NN BB GENERAL NOTES: (APPLIES TO ENTIRE DRAWING SET) 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LOCAL GOVERNING CODES, STANDARDS AND ORDINANCES AS ADOPTED AND ENFORCED BY THE AUTHORITY HAVING JURISDICTION, INCLUDING LOCAL AMENDMENTS. 2. DRAWINGS, IN GENERAL, ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO CONVEY, IN CONJUNCTION WITH THE COMPLETE CONTRACT DOCUMENTS, A COMPLETE AND FUNCTIONAL SYSTEM. COORDINATION OF WORK WITH OTHER TRADES IS REQUIRED BEFORE PROCEEDING WITH WORK. 3. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION FROM ARCHITECT BEFORE PROCEEDING. 4. CONTRACTOR SHALL PROVIDE A COMPLETE OPERATIONAL AND FUNCTIONING SYSTEM. CONTRACTOR SHALL PROVIDE CONNECTIONS TO OWNER OR OTHER PARTY'S EQUIPMENT AND DEVICES, UNLESS OTHERWISE NOTED. 5. REFERENCE COMPLETE CONSTRUCTION DOCUMENTS (ARCHITECTURAL, PLUMBING, ELECTRICAL, ETC.) PRIOR TO COMMENCING WORK FOR ADDITIONAL INFORMATION AND REQUIREMENTS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE OWNER'S/ARCHITECT'S ATTENTION BEFORE PROCEEDING WITH WORK. 6. CONTRACTOR SHALL MAINTAIN ON SITE, AVAILABLE FOR REVIEW, A MASTER SET OF MARKED UP DRAWINGS REFLECTING "AS BUILT" CONDITIONS. UPON CONCLUSION OF PROJECT, "AS BUILT" DRAWINGS SHALL BE TURNED OVER TO OWNER. 7. DETAILS AND SECTIONS ARE INTENDED TO BE TYPICAL AND INDICATE BASIC DESIGN INTENT AND SHALL APPLY TO SIMILAR SITUATIONS. ADAPTATIONS TO SPECIFIC PROJECT CONDITIONS MAY BE REQUIRED. BASIC DESIGN INTENT IS TO BE RETAINED. 8. AFTER COMPLETION OF WORK ALL ADDITIONAL MATERIALS REMAINING DUE TO CONSTRUCTION SHALL BECOME THE PROPERTY OF THE GENERAL CONTRACTOR AND SHALL BE DISPOSED OF REMOVED FROM THE SITE IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, AND REGULATIONS UNLESS NOTIFIED OTHERWISE CONTRACTOR SHALL ALSO REMOVE ALL WASTE DEBRIS, RUBBISH, TOOLS, EQUIPMENT AND SURPLUS MATERIALS UPON COMPLETION OF WORK THROUGHOUT CONSTRUCTION, SITE SHALL BE ORGANIZED AND CLEANED BY CONTRACTOR ON A DAILY BASIS. 9. PENETRATIONS INTO OR THROUGH, OF EITHER VERTICAL OR HORIZONTAL FIRE RATED BARRIERS SHALL BE PROTECTED BY A SYSTEM LISTED BY A RECOGNIZED TESTING AGENCY. PROVIDE A DETAIL AND LISTING NUMBER PER NFPA 101 LIFE SAFETY CODE. 10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF EQUIPMENT AND DEVICES AT CEILING . IF AN ITEM IS NOT SHOWN SUBMIT RECOMMENDED LOCATION FOR ARCHITECT'S APPROVAL. 11. MATERIALS EXPOSED WITHIN SPACES ABOVE A CEILING BEING UTILIZED AS A RETURN AIR PLENUM SHALL BE NON-COMBUSTIBLE, OR SHALL HAVE A FLAME-SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50, AS DETERMINED IN ACCORDANCE WITH ASTM E84. 12. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH ITEM OF EQUIPMENT PRIOR TO ORDERING. 13. SMOKE DETECTORS SHALL BE LOCATED AS INDICATED IN THE MECHANICAL SCHEDULES. DESIGN NOTES: 1. OUTDOOR AIR DESIGN CONDITIONS: CHARLOTTE, NORTH CAROLINA ASHRAE FUNDAMENTALS HANDBOOK - 2017 SUMMER - 91.8°F DB / 74.1°F WB (1% COLUMN) WINTER - 25.3°F (99% COLUMN) 2. INDOOR DESIGN CONDITIONS: SUMMER - 75°F WINTER - 70°F DUCT WORK NOTES: 1. EXHAUST AIR DISCHARGE SHALL BE A MINIMUM OF THREE FEET HIGHER THAN OR A MINIMUM OF TEN FEET FROM INTAKE HOODS. 2. ALL LAY-IN DIFFUSERS SHALL HAVE FOUR-WAY BLOW UNLESS NOTED OTHERWISE. 3. MOUNTING FRAME OF CEILING MOUNTED AIR DISTRIBUTION DEVICES SHALL BE COMPATIBLE WITH CEILING TYPE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. 4. PORTIONS OF DUCTWORK OR PIPING VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 5. MOUNT THERMOSTATS AND/OR TEMPERATURE SENSORS WHERE INDICATED ON PLANS, 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. 6. TRANSITION RECTANGULAR DUCTWORK ON THE BOTTOM AND THE SIDES. MAINTAIN DUCTWORK LEVEL AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE. 7. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH TRANSITION. SPIN-INS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. 8. LINE ALL RETURN AIR DUCTWORK. 9. DUCT SIZES ARE SHOWN AS INSIDE CLEAR DIMENSIONS. 10. BRANCH ROUND DUCTWORK LOCATED ABOVE INACCESSIBLE CEILING OR SERVING MORE THAN ONE DIFFUSER SHALL HAVE MANUAL DAMPER OMITTED AND HAVE FACE OPERATED DAMPER IN EACH DIFFUSER UNLESS NOTED OTHERWISE. 11. FLEXIBLE DUCT RUNOUTS TO DIFFUSERS SHALL BE INSTALLED FREE OF KINKS AND SAGS. ALL DIFFUSER RUNOUTS SHALL BE SIZED TO MATCH THE INLET OF THE DIFFUSER SERVED. MAX. LENGTH OF FLEXIBLE DUCT IS 6'-0" IN PUBLIC AREAS AND 25'-0" IN THE APARTMENTS. 12. ACOUSTICALLY SEAL ALL DUCTWORK AND PIPING PENETRATIONS AT DEMISING PARTITIONS TO STRUCTURE. 13. ALL FIRE AND FIRE/SMOKE DAMPERS, IF REQUIRED, SHALL MEET OR EXCEED RATING OF PARTITION IN WHICH INSTALLED AS REQUIRED BY NORTH CAROLINA MECHANICAL CODE, 2012. 14. KITCHEN EXHAUST, DRYER EXHAUST, AND COMBUSTION AIR DUCTS SHALL BE SHEET METAL. 15. CEILING HEIGHTS SHOWN ON ARCHITECTURAL DRAWINGS MUST BE MAINTAINED. NO DUCTWORK SHALL BE FABRICATED PRIOR TO RECEIPT OF ACCEPTABLE SHOP DRAWINGS. EQUIPMENT NOTES: 1. COORDINATE POWER REQUIREMENTS FOR THE BMS SYSTEM WITH THE ELECTRICAL CONTRACTOR. 2. DASHED DOT LINE AROUND EQUIPMENT INDICATES MANUFACTURER'S RECOMMENDED CLEARANCES FOR SERVICE, MAINTENANCE AND ACCESS. CONTRACTOR SHALL MAINTAIN ALL REQUIRED CLEARANCES FOR ACTUAL EQUIPMENT INSTALLED. 3. PROVIDE 4" HOUSEKEEPING PAD WITH NEOPRENE VIBRATION ISOLATORS UNDER EQUIPMENT IN THE MECHANICAL ROOM. ROOF PLAN NOTES: 1. CURB MOUNTED EQUIPMENT ROUTE PIPING AND CIRCUITING WITHIN CURB. 2. SEAL RACEWAYS AT BOUNDARIES OF COLD AND WARM ENVIRONMENTS. 3. ROOF PENETRATIONS SHALL BE IN ACCORDANCE WITH ROOFING SYSTEM'S INSTRUCTIONS. 4. INSTALL PIPING, RACKS, AND EQUIPMENT AWAY FROM ROOF'S EDGE AND BELOW PARAPET TO PREVENT BEING VISIBLE FROM PUBLIC AREAS. PAINT EQUIPMENT AND RACEWAYS AS NECESSARY TO MATCH SURROUNDING AREAS. 5. MAINTAIN SEPARATION OF EXHAUST AND INLETS AS REQUIRED BY CODE. 6. INSTALL EQUIPMENT AND DUCTWORK TO PREVENT STANDING WATER ON FLAT SURFACES. 7. MAINTAIN WORKING CLEARANCES FOR ACCESS PANELS AND EQUIPMENT DOORS. 8. USE CORROSION RESISTANCE MATERIALS AND FASTENERS. PAINT CUT FERROUS METALS WITH ZINC RICH PAINT. PIPING NOTES: 1. ALL PIPING TO BE ROUTED AS HIGH AS POSSIBLE. 2. ALL REFRIGERANT PIPING SHALL BE LOCATED IN WALLS OF APARTMENTS AND SHALL BE SPACED A MINIMUM OF 1” FROM BACK OF GYPSUM BOARD. LOCATE PIPING TO LIMIT POTENTIAL DAMAGE FROM ANY ITEMS PENETRATING WALLS. 3. ACOUSTICALLY SEAL ALL PIPING PENETRATIONS AT DEMISING PARTITIONS TO STRUCTURE. 4. CONTRACTOR TO COORDINATE ROUTING OF REFRIGERANT PIPING IN WALLS WITH STRUCTURAL DESIGN AND OTHER TRADES. CONTRACTOR SHALL PROVIDE PIPING PLAN FOR REVIEW PRIOR TO STARTING INSTALLATION. 5. ALL VALVES SHALL BE ACCESSIBLE THROUGH THE CEILING. PROVIDE ACCESS PANELS WHERE CEILING IS NOT ACCESSIBLE. 6. AN AUTOMATIC AIR VENT SHALL BE PROVIDED AT THE HIGH POINT OF CONDENSER WATER PIPING AND DRAIN LINE SHALL BE ROUTED TO THE MECHANICAL ROOM FLOOR DRAIN. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:22:00 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM0−01 08.14.18MECHANICAL LEGENDS AND NOTES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SHEET INDEX Sheet Number Sheet Name M0-01 MECHANICAL LEGENDS AND NOTES M1-01 MECHANICAL FLOOR PLAN - LEVEL 01 - GROUND LEVEL M1-02 MECHANICAL FLOOR PLAN - LEVEL 02 - PARKING LEVEL P2 M1-03 MECHANICAL FLOOR PLAN - LEVEL 03-07 - TYPICAL PARKING LEVELS P3-P7 M1-08 MECHANICAL FLOOR PLAN - LEVEL 08 - PARKING LEVEL P8 M1-09 MECHANICAL FLOOR PLAN - LEVEL 09-14 - TYPICAL OFFICE LEVELS O1-O5 M1-15 MECHANICAL FLOOR PLAN - LEVEL 15-16 - TYPICAL OFFICE LEVELS O6-O7 M1-17 MECHANICAL FLOOR PLAN - LEVEL 17 - INTERSTITIAL LEVEL M1-18 MECHANICAL FLOOR PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 M1-19 MECHANICAL FLOOR PLAN - LEVEL 19-29 - TYPICAL RESIDENTIAL UNIT LEVELS R2-R12 M1-30 MECHANICAL FLOOR PLAN - LEVEL 30 - ROOF PLAN M1-31 MECHANICAL FLOOR PLAN - LEVEL 31 - PENTHOUSE ROOF M3-01 MECHANICAL UNIT PLANS M3-02 MECHANICAL UNIT PLANS M3-03 MECHANICAL UNIT PLANS M3-04 MECHANICAL UNIT PLANS M3-05 MECHANICAL UNIT PLANS M4-01 MECHANICAL CONDENSER WATER FLOW DIAGRAM M4-02 MECHANICAL OUTSIDE AIR RISER DIAGRAM M4-03 MECHANICAL STAIR PRESSURIZATION DIAGRAM M5-01 MECHANICAL SCHEDULES M5-02 MECHANICAL SCHEDULES M6-01 MECHANICAL DETAILS M6-02 MECHANICAL DETAILS M6-03 MECHANICAL DETAILS M6-04 MECHANICAL DETAILS Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FCU-01-01 AND 02 102 OFFICE LOBBY 1825 10 19 5 0.06 205 1 122 OFFICE MAILROOM 114 5 1 5 0.06 12 1 123 BUILDING MAINTENANCE 106 5 1 5 0.06 11 1 126 RESIDENTIAL MAILROOM 213 10 2 5 0.06 23 1 128 RESIDENTIAL CORRIDOR 813 0 0 0 0.06 49 Ventilation Efficiency (Ev) = 1 Occupant Diversity (D) = 1.00 299 Zone Effectiveness (Ez) = 0.8 299 Notes:Total Required 299 1. Occupancy based upon occupant density from 2012 NC Mechanical Code.Total Provided 400 Uncorrected Total Required Corrected Total Required OA Calculation Per 2012 North Carolina Mechanical Code Room No. Room Sq. Ft. People/ 1000 Sq. Ft People CFM/ Person CFM/ Sq. Ft. Total CFM Notes FEC FECFECFEFE FEFECFVC GENERAL NOTES: KEY NOTES: RETAIL SPACE -SPLIT SYSTEM(S) BY TENANT. OUTSIDE AIR AND EXHAUST AIR SHALL BE PROVIDED FROM EXTERIOR CONTINUOUS BAND IN BUILDING FACADE BY TENANT PROVIDED LOUVER(S). PROVIDE SLEEVE FOR SET(S) OF REFRIGERANT LINES UP TO LEVEL 03 FOR RETAIL TENANT. FUTURE OUTSIDE AIR/INTAKE FOR FIRST FLOOR RESIDENTIAL LOBBY FROM EXTERIOR CONTINUOUS BAND IN BUILDING FACADE. EXHAUST AIR TO EXTERIOR BUILDING FACADE, PROVIDE VENT CAP. INTAKE AIR FROM EXTERIOR BUILDING FACADE, PROVIDE INTAKE CAP, MINIMUM SIZE AS NOTED. INTAKE HOOD ON ROOF WITH MOTORIZED DAMPER. INTERLOCK DAMPER WITH EXHAUST FAN. ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. ELECTRIC UNIT HEATER, SUSPENDED FROM STRUTURE/WALL, WITH UNIT MOUNTED THERMOSTAT. ELECTRIC HEATER SHALL BE INSTALLED ABOVE THE CEILING. HEATER SHALL BE PLENUM RATED. FAN COIL UNIT , FLOOR MOUNTED. ROUTE REFRIGERANT LINES TO CONDENSING UNIT ON LEVEL 02, P-2. INLINE FAN FOR VENTILATION. DUCTLESS SPLIT INDOOR FAN COIL UNIT ABOVE DOOR OR INSTALLED ABOVE 6'-8". ROUTE REFRIGERNAT LINES TO CONDENSING UNIT ON LEVEL 02. CONTINUOUS LINEAR SUPPLY AIR SLOT, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LENGTH. PORTION OF SLOT NOT USED SHALL BE BLANKED OFF. RETURN AIR SHALL BE PROVIDED THROUGH ARCHITECTURAL OPENINGS (6.0 MINIMUN S.F. FREE AREA) IN THE TIERED CEILINGS. MINIMUM OPEN AREA IS 50 LINEAR FEET BY 1 1/2 INCHES. REFER TO ARCHETECTURAL DRAWINGS. 12" ROUND FROM GENERATOR TO EXTERIOR. INSULATE PIPE WITH 2" OF CALCIUM SILICATE. TRANSFER AIR DUCT ABOVE CEILINGS; SIZE AS NOTED. INTAKE LOUVER, MINIMUM SF FREE AREA AS NOTED WITH INSULATED PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. NOTE WIDTH TO BE INCREASED IF DUCTWORK IS DROPPING OUT OF BOTTOM OF PLENUM. PROVIDE FIRE DAMPER AS NOTED. EXHAUST/RELIEF LOUVER, MINIMUM SF FREE AREA AS NOTED WITH PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. NOTE WIDTH TO BE INCREASED IF DUCTWORK IS DROPPING OUT OF BOTTOM OF PLENUM. PROVIDE FIRE DAMPER AS NOTED. PROVDIE 16 GAUGE WIRE MESS OVER DUCTWORK OPENING IN TRASH ROOM. TRENCH HEATER WITH CONTINUOUS LINEAR FLOOR GRILLE -TYPE "L", REFER TO SCHEDULE ON M5-01. 45° INTAKE HOOD, SIZE AS NOTED WITH MESH SCREEN. PROVIDE FIRE DAMPER AS NOTED. TRENCH HEATER SHALL BE PROVIDED IN A SEPARATE PERMIT. PROVIDE CONCRETE TRENCH FOR HEATER AT THIS TIME. OUTSIDE SENSOR SHALL ENERGIZE TRENCH HEATERS IN LOBBY WHEN OUTDOOR AIR IS 50°F OR LOWER. FAN COIL UNITS SERVING THE LOBBY SHALL EACH BE CONTROLLED BY A PROGRAMMABLE THERMOSTAT LOCATED IN THE BUILDING MAINTENANCE ROOM WITH REMOTE SENSOR LOCATED IN THE SPACE AS SHOWN. SENSOR SHALL BE ACI BUTTON SENSOR WITH STAINLESS STEEL FINISH. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 15 16 17 18 19 20 21 22 23 24 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 1 21212121212121212121212121212 2 1 OA AIR 3 EH-017 FCU-01-01 FCU-01-02 10 10 5 F-01-05 4 EH-0288EH-02 DFCU-01-01 12 DFCU-01-0212 EH-01 9 F-01-03 11 EH-0312 EH-03 12 EH-01 7 DFCU-01-0312 18 EH-02 8 EH-01 7 H-01-01 11 17 F-01-01 SD SERVICE ELEVATOR LOBBY 119 MAIN ELECTRICAL ROOM 124 O3 TO3 O1 TO1 O2 TO2 BUILDING MAINTENANCE 130 STAIR #2 ST2 RESIDENTIAL SERVICE CORRID0R 128 JANITOR'S CLOSET 123 TELECOM 121 FD FD FD EMERGENCY ELECTRICAL ROOM 125 FIRE PUMP ROOM 110 FIRE COMMAND CENTER 108 EMERGENCY GENERATOR ROOM 117 RESIDENTIAL MAILROOM 126 BOH RESTROOM 134 14 14 1 212121212 12"x12" EH-06EH-05 12"x10"18"x10" 12"x10"20"x12"S S EH-08 EH-07 FD FD6"x6" H 200 CFM 6"x6" K 200 CFM 6"ø12"ø 10"ø F-01-06 LINE OF BUILDING FACADE LINE OF BUILDING FACADE FD FD SLOPE DUCTWORK WITH RAMP DOWN 4 FD 8"ø 6"x6" H 75 CFM (TYP 2)8"ø8"ø8"ø8"øF-01-04 1 21212 8"ø F 200 CFM 6"ø F 100 CFM 8"ø F 200 CFM 8"x6" K 125 CFM 8"ø E 150 CFM 8"x6" K 50 CFM 8"ø F 150 CFM 6"x6" K 75 CFM 24"x16" J 6"ø E 100 CFM FCU-01-02 FCU-01-01 G 6"x6" J24"x18"4'-0" 4'-0" 4'-0" 18"x18" T MOD 4'-0" EH-02 EH-02 8 8 MOD FD 12"x12" H 350 CFM 11'-0" AFF 16"x16"16"x16"19 12"ø 15 90.0 SF FREE AREA 40.0 SF FREE AREA HIGH 40.0 SF FREE AREA HIGH68.0 SF FREE AREA 10"ø10"ø10"x10" 10"ø 12"x12"4'-0" FD FD MOD 5.0 SF FREE AREA 3.0 SF FREE AREA T 3.0 SF FREE AREA 4.0 SF FREE AREA MOD 19 14"x6" K 250 CFM F-01-02 18 21 16"x16"14"x14"171186 1.0 SF FREE AREA 1.0 SF FREE AREA FD FD F-01-07 11 11 CONTINUOUS TYP 8 TAPS, 4' PLENUMS 1600 CFM TOTAL 13 11 11 11 12"x12"14"x12"24"x16" J 8"x6" 8"x6" J 8"x8"24"x24" C G 10"x10" 4'-0" 8"x8" 16 16 16 16 GENERATOR 20 20 2020 NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. 20X12 IN VERTICAL FD R1 TR1 R2 TR2 MOD MOD 8"ø F 200 CFM CONTINUOUS SLOT 1 TAP 200 CFM TOTALCONTINUOUS SLOT 2 TAPS 400 CFM TOTAL EH-02 8 22 22 R3 TR324"x16"16 FD 12"x12" 24 13 13TYP. 2 16 S 23 T T FCU-01-01 FCU-01-02 24 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/14/2018 4:33:30 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−01 08.14.18MECHANICAL FLOOR PLAN − LEVEL 01 − GROUND LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-01 1 MECHANICAL FLOOR PLAN - LEVEL 01 - GROUND LEVEL Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FEFEFE FEFE1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 3 M4-03 5 M4-03 F-02-01 DFCU-XX-01 48"x12" CU-01-01 CU-01-02 DCU-01-02 DCU-01-01 6 DCU-01-03 2 5 7 2 2 6 1 ST-2 C ST-1 B STAIR #2 ST2 O1 TO1 O2 TO2 EH-013 EH-04 4 30"x30"48"x12"30"x8" K 1000 CFM 30"x8" K 1000 CFM EH-01 3 FD 20.0 SF FREE AREA 8 FSD FSD MOD 9 9 9 RESIDENTIAL / FIREMANS ELEVATOR LOBBY 207 STAIR #1 ST1 O4 TO4 O3 TO3 DRY SPRINKLER ROOM 206 PARKING DECK ELEVATOR S1 PARKING DECK ELEVATOR VESTIBULE 210 R3 TR3 R1 TR1 R2 TR2 GENERAL NOTES: KEY NOTES: DUCTLESS SPLIT INDOOR FAN COIL UNIT ABOVE DOOR OR INSTALLED ABOVE 6'-8". ROUTE REFRIGERANT LINES TO CONDENSING UNIT ON THIS LEVEL. DUCTLESS SPLIT CONDENSING UNIT. ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. SURFACE MOUNTED CEILING HEATER WITH INTEGRAL THERMOSTAT. INLINE FAN FOR STAIR PRESSURIZATION. FAN SHALL BE FLOOR MOUNTED WITH FIELD FABRICATED SUPPORTS AND NEOPRENE VIBRATION ISOLATION PADS. PROVIDE FIRE WRAP OR RATED ENCLOSURE AROUND DUCTWORK FROM INTAKE AIR LOUVER. DUCTWORK IN STAIRWELL SHALL BE IN RATED ENCLOSURE. CONDENSING UNIT. FUTURE ROUTE FOR REFRIGERANT LINES FROM RETAIL ON LEVEL 01 TO LEVEL 03. INTAKE LOUVER, MINIMUM SF FREE AREA AS NOTED WITH PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. PROVIDE FIRE DAMPER AS NOTED. PROVIDE DRAIN PAN UNDER HEAT PUMP CONDENSING UNIT FOR CONDENSATE. 1 2 3 4 5 6 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 7 8 9 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:15:37 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−02 08.14.18MECHANICAL FLOOR PLAN − LEVEL 02 − PARKING LEVEL P2401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-02 1 MECHANICAL FLOOR PLAN - LEVEL 02 - PARKING LEVEL P2 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FEFEFE FEFE 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 3 M4-03 5 M4-03 1 EH-013 ST-2 C ST-1 B O1 TO1 O2 TO2 PARKING DECK ELEVATOR S1 7 2 EH-04 4 ELECTRICAL ROOM 508 O4 TO4 O3 TO3 ? ? ? ? RESIDENTIAL / FIREMANS LOBBY 507 STAIR #1 ST1 DRY SPRINKLER ROOM 506 STAIR #2 ST2 PARKING DECK ELEVATOR VESTIBULE 510 11 11 12 12 R3 TR3 TELECOM ROOM 509 14 13 DFCU-XX-01 GENERAL NOTES: KEY NOTES: DUCTLESS SPLIT INDOOR FAN COIL UNIT ABOVE DOOR OR INSTALLED ABOVE 6'-8". ROUTE REFRIGERNAT LINES TO CONDENSING UNIT. DUCTLESS SPLIT CONDENSING UNIT. ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. SURFACE MOUNTED CEILING HEATER WITH INTEGRAL THERMOSTAT.EQUIPMENT NOTED OCCURS IN THIS LOCATION ON LEVELS 3 THRU 6 ONLY. FUTURE CONDENSING UNITS. UNIT SHALL BE PROVIDED AND PERMITTED UNDER SEPARATE PACKAGE. EQUIPMENT NOTED OCCURS IN THIS LOCATION ON LEVEL 3 ONLY. FUTURE ROUTE FOR REFRIGERANT LINES FROM RETAIL ON LEVEL 01. OCCURS ON LEVEL 03 ONLY. DUCTLESS SPLIT CONDENSING UNIT FOR LEVEL 2, OCCURS ON LEVEL 3 ONLY. INTAKE DUCT FROM LOUVER WITH MOTOR OPERATED DAMPER, INTERLOCKED WITH FAN. INLINE FAN, TERMINATE DUCTWORK AT LOUVER. FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH AND BE ENERGIZED FOR AN ADDITIONAL 15 MINUTES AFTER LIGHTS HAVE BEEN TURNED OFF. ARCHITECTURAL LOUVER, MINIMUN 1.0 SF FREE AREA, WITH INSULATED PLENUM FULL SIZE OF LOUVER BY 12" DEEP. DUCTLESS SPLIT CONDENSING UNIT, OCCURS ON LEVELS 3 AND 6. PROVIDE DRAIN PAN UNDER HEAT PUMP CONDENSING UNIT FOR CONDENSATE. DUCTLESS SPLIT CONDENSING UNIT. ONLY OCCURS ON LEVEL 7. DUCTLESS SPLIT INDOOR FAN COIL UNIT AT TOP OF ELEVATOR SHAFT. ROUTE REGRIGERANT LINES TO CONDENSING UNIT. OCCURS ON LEVEL 7 ONLY. 1 2 3 4 5 6 7 8 9 10 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 11 12 13 14 8 F E.2 7.8 6.8 7.9 6.7 E.9 DFCU-07-02 8"x8" J F-07-01 MOD8"x8" 10 8 10 1 FD DOG WASH 713 9 D.1 D D.0.5 D.4 C.9 4.95 D.2 5.3 DFCU-03-02 DFCU-06-02 2 2 CU-01-03 CU-01-04CU-01-05CU-01-06DCU-03-02FUTURE RETAILFUTURE RETAIL5555DCU-XX-01 DCU-06-02 DCU-XX-01 6 7 2 11 11 12 12 DFCU-07-03 DCU-07-03 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:28:23 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−03 08.14.18MECHANICAL FLOOR PLAN − LEVEL 03−07 − TYPICAL PARKING LEVELS P3−P7401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-03 1 MECHANICAL FLOOR PLAN - LEVEL 03-07 - TYPICAL PARKING LEVELS P3-P7 SCALE: 1/8" = 1'-0"M1-03 3 MECHANICAL FLOOR PLAN -LEVEL 7 - DOG WASH SCALE: 1/8" = 1'-0"M1-03 4 MECHANICAL FLOOR PLAN - LEVEL 03 AND 06 - ELECTRICAL ROOMS Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FE FEFE1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 3 M4-03 5 M4-03 F-08-01 DFCU-XX-011 6 EH-013 ST-2 C 4 M4-03 ST-2 B ST-1 B 2EH-03 EH-03 EH-03 EH-03EH-03EH-03 EH-03 EH-03 5 5 555 5 5 EH-03 5 DCU-XX-012MOD EH-03 EH-03 EH-03 EH-03 5 5 5 2DCU-XX-01DCU-07-02O2 TO2 O1 TO1 STAIR #2 ST2 5 7WALKWAY ABOVE DRIVE AISLE 5 48"x12"30"x30"4 RESIDENTIAL FIREMANS LOBBY 807 O4 TO4 O3 TO3 STAIR #1 ST1 DCU-08-022DFCU-08-02 1 8888GENERAL NOTES: KEY NOTES: DUCTLESS SPLIT INDOOR FAN COIL UNIT ABOVE DOOR OR INSTALLED ABOVE 6'-8". ROUTE REFRIGERNAT LINES TO CONDENSING UNIT. DUCTLESS SPLIT CONDENSING UNIT. ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. 45° INTAKE HOOD, SIZE AS NOTED WITH MESH SCREEN. PROVIDE FIRE DAMPER AS NOTED. PLENUM RATED HEATERS WITH UNIT MOUNTED THERMOSTAT ABOVE CEILING FOR OFFICE FLOOR ABOVE. INLINE FAN FOR STAIR PRESSURIZATION. FAN SHALL BE SUSPENDED FROM STRUCTURE WITH VIBRATION ISOLATION HANGERS. PROVIDE FIRE WRAP OR RATED ENCLOSURE AROUND DUCTWORK FROM INTAKE AIR HOOD. DUCTWORK IN STAIRWELL SHALL BE IN RATED ENCLOSURE. LOCATION OF LEVEL 7 CONDENSING UNIT. PROVIDE DRAIN PAN UNDER HEAT PUMP CONDENSING UNIT FOR CONDENSATE. 1 2 3 4 5 6 7 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 8 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:16:59 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−08 08.14.18MECHANICAL FLOOR PLAN − LEVEL 08 − PARKING LEVEL P8401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-08 1 MECHANICAL FLOOR PLAN - LEVEL 08 - PARKING LEVEL P8 FD Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FE FECFVC FE1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 1 2121212 3 M4-0328"x12"72"x20" 1725 CFM RELIEF64"x20"64"x20"12 3 4 5 5 88 PIU-XX-01 6 4 M4-03 3 M4-02 MOD FSD 4 M4-02 RA 1 OA 3 ST-2 B ST-1 B FSD SCU-XX-01 48"x30" 24"x30" 2 4 "x 3 0 "MOD 3000 CFM 2400 CFM ELEVATOR LOBBY 901 FIREMANS ELEVATOR LOBBY 907 TELECOM ROOM 909 ELECTRICAL ROOM 908 TENANT CORRIDOR 911 STAIR #2 ST2 SERVICE ELEVATOR LOBBY 905 MECHANICAL ROOM 906 O1 TO1 O2 TO2 WOMEN'S BATHROOM 903 MEN'S BATHROOM 902 STAIR #1 ST1 1 21212121212 12"x12" C 75 CFM 10"x10" 10"x10" 6"Ø (TYP. 8)12"x12"6"x6" H 75 CFM 8"ø E 150 CFM 4'-0" 6"ø E 100 CFM 8"ø E 150 CFM 4'-0" 2'-0" 8"ø E 150 CFM 4'-0"8"x8"8"x8" K 250 CFM O3 TO3 O4 TO4 JANITOR'S CLOSET 904 MECHANICAL ROOM 906 G EH-097 EH-09 EH-09 EH-09EH-09 7 7 7 7 EH-09 7 10 8"ø10"ø10"øLEVEL O1 0NLY8T T 8"x8" F-XX-01 1 2 8"x8" H 250 CFM 9 10 SD 4'-0" 11 FSD PIU-XX-01 F-XX-01 SD SD R3 TR3 R1 TR1 R2 TR2 12 12 12 12 FD FD FD1314 14 13 GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. MATERIALS EXPOSED WITHIN SPACES ABOVE A CEILING BEING UTILIZED AS A RETURN AIR PLENUM SHALL BE NON-COMMBUSTIBLE, OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50, AS DETERMINED IN ACCORDANCE WITH ASTM E84. 3. DUCTWORK DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. KEY NOTES: SELF CONTAINED WATER PACKAGE UNIT, 17,500 CFM. PROVIDE 4" HOUSEKEEPING WITH NEOPRENE ISOLATION PADS, REFER TO DETAIL 9/M6-02. CONDENSER WATER SUPPY AND RETURN RISERS. PROVIDE 3" CWS&R WITH SHUT-OFF VALVES TO UNIT. REFER TO FLOW DIAGRAM FOR ADDITIONAL VALVES. OUTSIDE AIR RISER, 3000 CFM CONNECT 20X20 DUCT WITH FIRE SMOKE DAMPER AT CHASE PENETRATION. PROVIDE OUTDOOR AIR MONITORING STATION AND MOTORIZED DAMPER IN DUCTWORK TO REGULATE OUTSIDE AIR FLOW, INTERLOCK WITH RETURN/RELIEF MOTORIZED DAMPER. ALL OUTSIDE AIR DUCTWORK SHALL BE PROVIDED WITH 1-1/2" INSULATION, MINIMUM R=6. RELIEF/EXHAUST RISER. CONNECT 30X12 WITH FIRE SMOKE DAMPERS AT CHASE PENETRATION, 2400 CFM TOTAL. PROVIDE MOTORIZED INTERLOCKED WITH OA MOTORIZED DAMPER. RETURN AIR DUCTWORK, SIZE AS NOTED, SHALL BE LINED WITH 1" LINING. SERIES POWERED INDUCTION UNIT. REFER TO DETAIL 2/M6-03. PROVIDE LOW PRESSURE DUCTWORK AND AIR DISTRIBUTION IN BASE BUILDING PACKAGE. UNIT HEATERS WITH UNIT MOUNTED THERMOSTAT INSTALLED TO TEMPER SPACE PRIOR TO TENANT OCCUPANCY. 10" Ø FROM MP DUCT TO SERIES CORE BOX. DUCT IS TEMPORARY UNTIL MP DUCTWORK IS INSTALLED. WHEN MP DUCTWORK IS INSTALLED, CONNECT AS NOTED ON M1-15. TRANSFER AIR OPENING ABOVE THE CEILING, SIZE AS NOTED. REFER TO ARCHITECTURAL DRAWINGS IF ELEVATOR LOBBY IS TO BE FINISHED AT THIS TIME. IF NOT, CAP DUCTWORK ABOVE THE LOBBY CEILING FOR FUTURE. SMOKE DETECTOR -CEILING MOUNTED BEHIND UNIT IN RETURN AIR PATH. FOR FUTURE ROUTING. MEDIUM PRESSURE DUCT SHALL BE INSTALLED A MINIMUM OF 8'-0" FROM THE PERIMETER OF THE CORE WALLS. PROVIDE 1-1/2" INSULATION, MINIMUM R=6. MEDIUM PRESSURE DUCTWORK SHALL EXTEND TO CLEAR STAIR ON LEVEL 09, PLAN WEST SIDE. SEE SHEET M1-15 FOR LAYOUT. TRANSFER STAIR OCCURS ON LEVEL O1 ONLY, DOWN TO P8. SMOKE DAMPER AT WALL PENETRATION. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:17:28 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−09 08.14.18MECHANICAL FLOOR PLAN − LEVEL 09−14 − TYPICAL OFFICE LEVELS O1−O5401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-09 1 MECHANICAL FLOOR PLAN - LEVEL 09-14 - TYPICAL OFFICE LEVELS O1-O5 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FE FEC FECFVC FE1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 3 M4-03 4 M4-03 3 M4-02 4 M4-02 54"x14" 72"x20"54"x14"54"x14"42"x14"42"x14"PIU-XX-05 PIU-XX-04 PIU-XX-03 SCU-XX-01 12 3 4 5 5 6 8 8 8 8 8 PIU-XX-01 7 7 7 7 RA 1 OA 3 G 4'-0" 6"ø E 100 CFM 8"ø E 150 CFM 4'-0" 4'-0" 2'-0" 6"x6" H 75 CFM 8"x8" J 8"x8" K T F-XX-01 12"x12" C 75 CFM 6"Ø (TYP. 8)28"x12"12"x12"24"x30" 2 4 "x 3 0 "48"x30" MOD 8"x8"8"x8" H 150 CFM 10 9 MEN'S BATHROOM 1014 O3 TO3 O4 TO4 O2 TO2 O1 TO1 PIU-XX-02 SD 11 10"x10" MOD FSD ST-2 B ST-1 B FSD3000 CFM 2400 CFM TPIU-XX-01 F-XX-01 SD SD FD FD FD 8"ø E 150 CFM 4'-0" 10"x10" 8"ø E 150 CFM 12 12 GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. MATERIALS EXPOSED WITHIN SPACES ABOVE A CEILING BEING UTILIZED AS A RETURN AIR PLENUM SHALL BE NON-COMMBUSTIBLE, OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50, AS DETERMINED IN ACCORDANCE WITH ASTM E84. 3. DUCTWORK DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. KEY NOTES: SELF CONTAINED WATER PACKAGE UNIT, 17,500 CFM. PROVIDE 4" HOUSEKEEPING WITH NEOPRENE ISOLATION PADS, REFER TO DETAIL 9/M6-02. CONDENSER WATER SUPPY AND RETURN RISERS. PROVIDE 3" CWS&R WITH SHUT-OFF VALVES TO UNIT. REFER TO FLOW DIAGRAM FOR ADDITIONAL VALVES. OUTSIDE AIR RISER, 3000 CFM CONNECT 20X20 DUCT WITH FIRE SMOKE DAMPER AT CHASE PENETRATION. PROVIDE OUTDOOR AIR MONITORING STATION AND MOTORIZED DAMPER IN DUCTWORK TO REGULATE OUTSIDE AIR FLOW, INTERLOCK WITH RETURN/RELIEF MOTORIZED DAMPER. ALL OUTSIDE AIR DUCTWORK SHALL BE PROVIDED WITH 1-1/2" INSULATION, MINIMUM R=6. RELIEF/EXHAUST RISER. CONNECT 30X12 WITH FIRE SMOKE DAMPERS AT CHASE PENETRATION, 2400 CFM TOTAL. PROVIDE MOTORIZED INTERLOCKED WITH OA MOTORIZED DAMPER. RETURN AIR DUCTWORK, SIZE AS NOTED, SHALL BE LINED WITH 1" LINING. SERIES POWERED INDUCTION UNIT. REFER TO DETAIL 2/M6-03. PROVIDE LOW PRESSURE DUCTWORK AND AIR DISTRIBUTION IN BASE BUILDING PACKAGE AS NOTED. PARALLEL POWERED INDUCTION UNIT INSTALLED TO TEMPER SPACE PRIOR TO TENANT OCCUPANCY. PROVIDE THERMOSTAT WITH 100' WIRE, COILED UP BY UNIT. LOW PRESSURE DUCTWORK AND AIR DISTRIBUTIONTO BE PROVIDED BY TENANT. TENANTS SHALL PROVIDE ADDITIONAL BOXES AS REQUIRED. MEDIUM PRESSURE DUCT SHALL BE INSTALLED A MINIMUM OF 8'-0" FROM THE PERIMETER OF THE CORE WALLS. PROVIDE 1-1/2" INSULATION, MINIMUM R=6. TRANSFER AIR OPENING ABOVE THE CEILING, SIZE AS NOTED. REFER TO ARCHITECTURAL DRAWINGS IF ELEVATOR LOBBY IS TO BE FINISHED AT THIS TIME. IF NOT, CAP DUCTWORK ABOVE THE LOBBY CEILING FOR FUTURE. SMOKE DETECTOR -CEILING MOUNTED BEHIND UNIT IN RETURN AIR PATH. SMOKE DAMPER AT WALL PENETRATION. 1 2 3 4 5 6 7 8 9 10 11 12 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:27:26 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−15 08.14.18MECHANICAL FLOOR PLAN − LEVEL 15−16 − TYPICAL OFFICE LEVELS O6−O7401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-15 1 MECHANICAL FLOOR PLAN - LEVEL 15-16 - TYPICAL OFFICE LEVELS O6-O7 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION 1 1 8 823456 AA B B E.0.7 FF 7 C.1 D.1 E.8 B.9 C D 3.92.91.8 A.3 7.86.8 A.7 C.7.1 D.0.5 2.8 2.8 5.7 5.7 B.8 B.8 D.4D.4 B.1 C.2 7.1 5.9 D.2D.2 5.3 5.3 RESIDENTIAL SERVICE / FIREMANS ELEVATOR LOBBY 1707 STAIR #1 ST1STAIR #2 ST2 STAIR #2 ST2 UTILITY TRANSFER AREA 1713 POOL PUMP ROOM 1705 C.7.2 POOL CHEMICAL ROOM 1703 R1 TR1 R2 TR2 R3 TR3 3 M4-03 5.9 DFCU-17-01 4 M4-03 ST-2 B ST-1 B 3 M4-02 2 M1-17 4 M4-02 RA 1 4 EH-02 4 EH-02 4 EH-02 4 F-17-01 1 OA 3 3 UTILITY TRANSFER AREA 1713 8 9 CWS CWR CWSCWRCWR CWS CWSCWR60"x30"60"x30"66"x24" 50"x30" ERU-01 7 7 10 14 15 104"x52"104"x24"72"x36"16 FSD FSD 20"x20"20"x20"20"x20" MOD 20"x20"20"x20"20"x20"36"x12"12 EH-01 EH-01 EH-02 F-17-02 F-17-0350"x30"50"x30" 60"x30" 6"x6" K 100 CFM (TYP 2)8"ø6"ø8"ø 8"ø8"ø 20"x20"20"x20" 20"x20"40"x20"40"x20"48"x20"18"x18" 10"x10" K 300 CFM 10"x10" K 300 CFM 16"x14" 10"x10" K 300 CFM TYP.2 10"x10" K 300 CFM TYP.2 EH-02 EH-02 EH-024 4 EH-02 4 4DFCU-17-02 10"x10" K 300 CFM 10"x10" K 0 CFM 14"x14"10"x10"10"x10"12"x12" 12"x12" 18"x18"18"x18"BELOW POOL BOXBELOW POOL BOXSLOPE UP SLOPE DN 8"øSLOPE UP SLOPE DN FD FD FD DN EH-02 EH-02 4 4 8.0 SF FREE AREA 8.0 SF FREE AREA 14 15 13 FD FD 18 19 17 17 19 20"x20" FD 18 FD 7760.5 SF FREE AREA 13 FDFD 50.0 SF FREE AREA 14 2.0 SF FREE AREA FD 13 42.0 SF FREE AREA 12 11 6 5 5 121117 14"x14"6"x6" H 100 CFM 20 20 21 21 10"x10"10"x10"10"x10" K 300 CFM BD BD BD BD BD FD FDFD MOD FD FD FD FD FD 2210"x10"10"x10" K 300 CFM BD UP FROM OFFICE 30"x50"FD DOWN TO BELOW POOL BOX 48"x20" IN VERTICAL 10"x10" MOD GENERAL NOTES: KEY NOTES: INLINE FAN FOR STAIR PRESSURIZATION. FAN SHALL BE FLOOR MOUNTED WITH FIELD FABRICATED SUPPORTS AND NEOPRENE VIBRATION ISOLATION PADS. PROVIDE FIRE WRAP OR RATED ENCLOSURE AROUND DUCTWORK FROM INTAKE AIR LOUVER. DUCTWORK IN STAIRWELL SHALL BE IN RATED ENCLOSURE. OUTSIDE AIR DUCT DOWN TO OFFICE. PROVIDE FIRE SMOKE DAMPER AT CHASE PENETRATION. RETURN/RELIEF DUCT UP FROM OFFICE. PROVIDE FIRE SMOKE DAMPER AT CHASE PENETRATION. ELECTRIC UNIT HEATER SUSPENDED FROM STURCTURE, WITH UNIT MOUNTED THERMOSTAT. ELECTRIC WALL HEATER HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. 6" Ø EXHAUST AIR DUCT TERMINATE AT 12" ABOVE FINISHED FLOOR. PROVIDE BALANCING DAMPER IN VERTICAL. ROUTE DUCTWORK THRU STRUCTURAL BEAM PENETRATION. 8" CWS&R RISERS DOWN FROM PENTHOUSE. 8" CWS&R RISER DOWN TO OFFICE. ENERGY REVOCERY UNIT -PROVIDE 4" HOUSEKEEPING PAD FOR UNIT . ROUTE 4" CWS&R TO UNIT. MINIMUM HEIGHT CLEAR FOR UNIT IS 12'-0" CLEAR. RETURN/RELIEF AIR DUCTWORK SHALL BE ROUTED UP FROM OFFICE VERTICAL CHASE AND SHALL BE ROUTED TO THE ERU UNIT. PROVIDE FIRE SMOKE DAMPER AT CHASE PENETRATION. DUCTWORK SHALL BE INSULATED. OUTSIDE AIR DUCTWORK SHALL BE ROUTED FROM THE ERU UNIT TO THE OFFICE VERTICAL CHASE AND DOWN TO THE OFFICE SPACE. PROVIDE FIRE SMOKE DAMPER AT CHASE PENETRATION. DUCTWORK SHALL BE INSULATED. INTAKE LOUVER, MINIMUM SF FREE AREA AS NOTED WITH INSULATED PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. NOTE WIDTH TO BE INCREASED IF DUCTWORK IS DROPPING OUT OF BOTTOM OF PLENUM. PROVIDE FIRE DAMPER AS NOTED. EXHAUST/RELIEF LOUVER, MINIMUM SF FREE AREA AS NOTED WITH PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. NOTE WIDTH TO BE INCREASED IF DUCTWORK IS DROPPING OUT OF BOTTOM OF PLENUM. PROVIDE FIRE DAMPER AS NOTED. MAINTAIN MINIMUM 10'-0" BETWEEN INTAKE AND EXHAUST LOUVERS. DUCTWORK TRANSITION, MINIMUM 4'-0", BETWEEN UNITS. PRETREATED OUTSIDE AIR DUCT DOWN FROM FLOOR ABOVE; SIZE AS NOTED. PROVIDE FIRE DAMPER AT SLAB PENETRATION. RELIEF AIR DUCTWORK DOWN FROM FLOOR ABOVE; SIZE AS NOTED. PROVIDE FIRE DAMPER AT SLAB PENETRATION. OUTSIDE AIR DUCTWORK UP TO FLOOR ABOVE; SIZE AS NOTED. PROVIDE FIRE DAMPER AT SLAB PENETRATION. IN LINE FAN SUSPENDED FROM STRUCTURE. FANS F-17-02 AND F-17-03 SHALL BE INTERLOCKED TO OPERATE SIMULTANEOUSLY WITH MOTOR OPERATED DAMPER IN INTAKE DUCWORK TO FAN F-17-02 TO OPEN WHEN FANS ARE ENERGIZED. RELIEF AIR/EXHAUST DUCTWORK, PROVIDE FIRE DAMPER AT SLAB PENETRATION. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 18 19 20 21 22 84 LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" 4.93.9 7.85.8 6.85.7 7.96.74.95 5.95.3 30"x60" 24"x66" 3 0 "x 5 0 "30"x50" RA BEHIND SA 30"x60" 52"x104" 72"x36"24"x104"ERU-01 10 17 11 1112 13R2 LEVEL 939' - 7"36"x12"RA DUCTWORK 20"x20" 60"x30 OA 60"x30 RA TO OFFICE CHASE UNIT HEATER INLINE FAN c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:19:06 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−17 08.14.18MECHANICAL FLOOR PLAN − LEVEL 17 − INTERSTITIAL LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-17 1 MECHANICAL FLOOR PLAN - LEVEL 17 - INTERSTITIAL LEVEL SCALE: 1/8" = 1'-0"M1-17 2 INTERSTITIAL LEVEL ERU-01 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION R.DWFECFE R.FECDW R.R.DWR.DW R.R.DWR.R. DW DW R. R. DW 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 1 M4-02 2 M4-02 14"x6"22"x18"FSD(2) 8"x6" 12"x12" 2 1 1 1 1 2 2 2 1 10"x6"2 8"x6"1 1 3 3 13 6 EH-01 4 F-18-02 28"x18"20"x6"FSD 8"x6" 1 M4-03 2 M4-03 OA 1 OA 2 1 2 M1-17 4 M4-02 1 ST-1 A ST-2 A 3 MOD 3 LEASING OFFICE 1805 UNIT 1-K X091 UNIT 1-G X081 UNIT 1-H X071 UNIT 1-J X061 UNIT S-A X051 UNIT 1-A X041 UNIT 1-B X031 UNIT 1-B ALT X021 UNIT 1-C X011 CLUB ROOM 1824 YOGA ROOM 1821 FITNESS CENTER 1820 STAIR #1 ST1 JANITOR'S CLOSET 1809 5 8 14"x6" 2 14"x6" 18"x18"18"x18"14"x6" K 100 CFM 8"x6" K 135 CFM F-18-01 6"x6" C 50 CFM 8"x6" K 130 CFM 8"x6" K 130 CFM 8"x6" K 130 CFM FSDEH-03 EH-03 7 7 8"x6" 4"ø 8"x6" 6"x6" C 100 CFM 6"x6" C 50 CFM 9 9 EH-03 EH-03 7 7 6 12"x12" 12"x12" NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. 10 11 11 FSD FSD 9 6"x6"6"x6"6"x6" J TYP. 4 MOD 3 12 12 31212 MODMOD MOD FSD ELECTRICAL 1814 RESIDENTIAL / FIREMANS ELEVATOR LOBBY 1806 TYP. CORRIDOR 1730 R1 TR1 R2 TR2 R3 TR3 UNISEX BATHROOM 1807 MEN'S BATHROOM 1804 WOMEN'S BATHROOM 1803 8"x8" J (TYP.2) GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. KEY NOTES: 6X4 OA DUCT FOR APARTMENT UNITS FROM CORRIDOR, SEE INDIVIDUAL UNITS FOR CONTINUATION. OUTSIDE AIR FOR AMENITY SPACE AND LEASING AREA FROM OUTSIDE AIR UNIT. FUTURE FAN COIL UNIT. UNITS SHALL BE PROVIDED AND PERMITTED UNDER SEPARATE PACKAGE. CEILING CABINET FAN, TERMINATE DUCTWORK AT ARACHITECTURAL LOUVER. INLINE FAN, TERMINATE DUCTWORK AT ARCHITECTURAL LOUVEROUTSIDE OF BUILDING. ARCHITECTURAL LOUVER, MINIMUM 2 SF FREE AEA WITH INSULATED PLENUM FULL SIZE OF LOUVER BY MINIMUM 12" WIDTH. PLENUM RATED HEATERS WITH UNIT MOUNTED THERMOSTAT ABOVE CEILING FOR APARTMENT UNITS ABOVE. PROVIDE ACCESS PANELS FOR MAINTENANCE. REFER TO ACHITECTURAL DRAWINGS FOR LOCATION. 8" CWS & CWR RISERS. TRANSFER AIR DUCT ABOVE CEILING, SIZE AS NOTED. DUCT DOWN THROUGH GRILLE IN CORRIDOR. REFER TO TO DETAIL 8/M6-01. 18X18 PRETREATED OA DUCT DOWN TO FLOOR BELOW. PROVIDE FIRE DAMPER AT SLAB PENETRATION. 12X12 PRETREATED OA DUCT DOWN TO FLOOR BELOW. PROVIDE FIRE DAMPER AT SLAB PENETRATION. 20X20 OUTSIDE AIR/ REIELF AIR, UP FROM BELOW, SHALL BE CAPPED AT SLAB WITH FIRE DAMPER FOR FUTURE. ELECTRIC WALL HEATER HEATER WITH INTEGRAL THERMOSTAT. INSTALL HEATER AT 18" ABOVE THE FINISHED FLOOR. 1 2 3 4 5 6 7 8 9 10 11 12 13 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:18:31 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−18 08.14.18MECHANICAL FLOOR PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-18 1 MECHANICAL FLOOR PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FE FEC FECDW R. DW R.R.DWR. DW DWR.R.DW R.DWR.DWDW R.R.DW R.R.DWDW R.DWR.DW R. R. DW R. DW 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 1 M4-02 FSD(2) 2 M4-02 FSD(2) 10"x8"12"x6"10"x6"8"x6" 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 M4-03 2 M4-03 OA 1 OA 2 ST-1 A ST-2 A UNIT 1-B ALT X022 UNIT 1-B X032 UNIT 1-A X042 UNIT S-A X052 UNIT 1-J X062 UNIT 1-H X072 UNIT 1-G X082 UNIT 2-A X092 UNIT 1-F X102 ELECTRICAL ROOM 1914 RESIDENTIAL ELEVATOR LOBBY 1906 STAIR #1 ST1 UNIT 1-D X172 UNIT 1-C X012 UNIT 1-E X162 UNIT S-B X152 UNIT 2-C X142 UNIT S-D X132 UNIT 2-B X122 UNIT S-C X112 2 12"x6" 10"x6" 8"x6" K 100 CFM 8"x6" K 100 CFM 8"x6" K 125 CFM 8"x6" K 125 CFM 8"x6" J 8"x6" K 100 CFM (TYP 2)3 R2 TR2 R1 TR1 R3 TR3 GENERAL NOTES: KEY NOTES: 6" x 4" OA DUCT FOR APARTMENT UNITS FROM CORRIDOR. SEE INDIVIDUAL UNIT PLANS FOR CONTINUATION. 8" CWS & CWR RISERS. TRANSFER AIR DUCT ABOVE CEILING, SIZE AS NOTED. DUCT DOWN THROUGH GRILLE IN CORRIDOR. REFER TO TO DETAIL 8/M6-01. 1 2 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS OR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 3 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:17:58 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−19 08.14.18MECHANICAL FLOOR PLAN − LEVEL 19−29 − TYPICAL RESIDENTIAL UNIT LEVELSR2−R12401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-19 1 MECHANICAL FLOOR PLAN - LEVEL 19-29 - TYPICAL RESIDENTIAL UNIT LEVELS R2-R12 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FESDSDSDSD1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 1 M4-02 2 M4-02 F-R-02 OAU-02 OAU-01 1 M4-03 2 M4-03 CT-01 ST-1 A OA 1 OA 2 ST-2 A MOD 76"x16" 32"x32" P-05 P-04 P-06 EH-02 EH-02 MOD F-PH-01 HX-01 13 12 11 10 6 8 8 1 3 47 2 TYP. 2 TYP.2 TYP. 2 TYP. 4 9 (TYP 6) 14 15 ET-01 FSD FSD CU-18-03CU-18-02CU-18-01 32"x32"1 CHASE ABOVE ROOF OFFSET BELOW ROOF 16 TYP. 17 18 DFCU-R-01 DFCU-R-02 DCU-R-02 DCU-R-01 DCU-17-02 DCU-17-01 20 20 20 19 19 19 19 5 5 P-01 P-02 P-03 8"CWR 8"CWR 8"CWS10"CWS 10"CWR 1410"CWS 10"CWS CU-18-04 CU-18-05 MOD MOD CU-18-06 GENERAL NOTES: KEY NOTES: OUTSIDE AIR UNIT WITH GAS HEAT. PROVIDE ROOF SUPPORT/CURB FOR UNIT. ROUTE DUCTWORK ON ROOF AS NOTED. REFER TO DETAIL 3/M6-02. CONDENSING UNITS CU-A AND CU-B FOR RESIDENTIAL LEVELS; FUTURE AMENITY LEVEL UNITS ARE LABLED - PROVIDE MINIMUM 24" SUPPORT FRAME OFF ROOF. REFER TO DETAIL SHEET M6-04. ROOF MOUNTED VANE AXIAL STAIR PRESSURIZATION FAN. PROVIDE WEATHER PROOF/FIREWRAP OR RATED WEATHERPROOF ENCLOSURE AROUND DUCT TO SHAFT. OUTSIDE AIR DUCTWORK. PROVIDE FIRE SMOKE DAMPER AT CHASE PENETRATION. PROVIDE INSULATION WITH WEATHER PROOF ENCLOSURE. DUCTLESS SPLIT INDOOR FAN COIL UNIT IN ELEVATOR SHAFT, LOCATED AT TOP OF ELEVATOR. ROUTE REFRIGERANT LINES TO CONDENSING UNIT ON ROOF. INTAKE LOUVER, 3.0 SF FREE AREA, WITH MOTOR OPERATED DAMPER INTERLOCKED WITH EXHAUST FAN. INLINE EXHAUST FAN. ROUTE DUCTWORK TO LOUVER WITH AT LEAST 3.0 SF FREE AREA AND INTERLOCK FAN WITH MOTOR OPERATED INTAKE DAMPER. UNIT HEATER SUSPENDED FROM STRUCTURE WITH UNIT MOUNTED THERMOSTAT. CONDENSER WATER PUMP WITH INERTIA BASE PAD. HEAT EXCHANGER. PROVIDE HOUSEKEEPING PAD. FLOOR MOUNTED IN LINE AIR SEPARATOR. PROVIDE HOUSEKEEPING PAD. B&B ROLAIRTROL R-10F WITH STRAINER. FLOOR MOUNTED EXPANSION TANK . PROVIDE HOUSEKEEPING PAD. COOLING TOWER -2 CELL TOWER SHALL BE SUPPORT ON CONCRETE PIERS AND VIBRATION ISOLATION FRAME. TOP OF TOWER SHALL BE LEVEL WITH THE TALLEST SCREEN WALL. CONDENSER WATER PPING ON THE ROOF SHALL BE HEAT TRACED, INSULATED AND PROVIDED WITH WEATHER PROOF COVER. CONDENSER WATER RISERS DOWN TO OFFICE FLOORS. REFER TO FLOW DIAGRAM FOR PIPE SIZES. CHASE FOR REFRIGERANT LINES UP THRU ROOF TO CONDENSING UNIT. REFER TO DETAIL 2/M6-02. OFFSET CHASE BELOW ROOF WHERE NOTED. VENTILATION LOUVER WITH 6 SQUARE FEET FREE AREA WITH MOTOR OPERATED DAMPER THE INTERLOCKED WITH FIRE ALARM SYSTEM. REFER TO ARCHETECTURAL DRAWINGS FOR LOCATIONS AND SIZES. VENTILATION LOUVER WITH 3 SQUARE FEET FREE AREA WITH MOTOR OPERATED DAMPER THE INTERLOCKED WITH FIRE ALARM SYSTEM. REFER TO ARCHETECTURAL DRAWINGS FOR LOCATIONS AND SIZES. DUCTLESS SPLIT CONDENSING UNIT. PROVIDE ROOF SUPPORT FOR UNIT. REFER TO DETAIL 5/M6-02. FUTURE CONDENSING UNITS FOR PUBLIC AREAS ON AMENITY LEVEL. UNITS SHALL BE PROVIDED AND PERMITTED UNDER A SEPARATE PACKAGE. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND SIZE OF INTAKE AND EXHAUST LOUVERS. 3. ALL EXHAUST VENT LOCATIONS TO BE A MINIMUM OF TEN (10) FT FROM OOUTSIDE AIR INTAKE. 19 20 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:19:38 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−30 08.14.18MECHANICAL FLOOR PLAN − LEVEL 30 − ROOF PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-30 1 MECHANICAL FLOOR PLAN - LEVEL 30 - ROOF PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. KEY NOTES: ROOF MOUNTED VANE AXIAL STAIR PRESSURIZATION FAN. PROVIDE WEATHER PROOF/FIREWRAP OR RATED WEATHERPROOF ENCLOSURE AROUND DUCT TO SHAFT. 1 5 6 D.1 B.9 C D D.0.5 5.7 B.8 C.8 C.9 C.2 4.95 D.2 5.3 C.7.2 1 M4-03 1 76"x16"MOD F-R-01 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:22:25 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM1−31 08.14.18MECHANICAL FLOOR PLAN − LEVEL 31 − PENTHOUSE ROOF401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"M1-31 1 MECHANICAL FLOOR PLAN - LEVEL 31 - PENTHOUSE ROOF Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION R.DWFECR.DW DW R.R.DW6"x6" AA 25 CFM 10"x6" AA 125 CFM 10"x6" AA 150 CFM 10"x6" AA 175 CFM FCU-A 6"ø T 5 4 5 3 10 1 8 6 22 11 FCU-A 9 4"ø6"x6" BB 25 CFM 10"x6" BB 100 CFM 6"x6" BB 40 CFM14"x8"4"ø12 F-A GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. ADA UNITS ARE S-A, 1-B, 1-H, 2-A, AND ARE LOCATED ON R1, R2, AND R12. LAYOUTS ARE SIMILAR AND SIDEWALL DIFFUSERS SHALL BE REPLACED WITH CEILING DIFFUSERS. 3. SENSORY IMPAIRED UNITS ARE 1-H AND 2-A ON R3 AND S-A AND 1-B ON R11. KEY NOTES: 6"x4" OUTSIDE AIR DUCT TO OUTSIDE AIR SUPPLY DUCT IN CORRIDOR. UNDERCUT DOOR 1 INCH FOR TRANSFER AIR, BY OTHERS. SEE ARCHITECTURAL DRAWINGS. REFRIGERANT PIPING LINE SETS IN OPENING UP TO ROOF. SEE ARCHITECTURAL DRAWINGS FOR DRYWALL ENCLOSURE. 4"∅DRYER EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 4"∅OR 6"∅, SIZE AS NOTED ON PLAN, EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 6"∅UP FROM RANGE HOOD EXHAUST CONNECTION. PROVIDE TRANSITION TO RANGE HOOD EXHAUST CONNECTION. TRANSFER AIR DUCT WITH GRILLE, SIZE AS INDICATED; SEE DETAIL 8/M6-01. 4"∅DRYER VENT UP FROM TOP OF WALL MOUNTED DRYER BOX. DRYER BOX SHALL BE EQUAL TO IN-O-VATE TECHNOLOGIES DRYER BOX #350 WITH UPWARD EXHAUST DIRECTION COLLAR CONNECTION. DRYER EXHAUST AIR THROUGH 24X8 RETURN AIR GRILLE "CC" LOCATED ABOVE DOOR. GRILLES MUST PROVIDE A MINIMUM OF 100 SQ.IN. FREE AREA. 24X8 RETURN AIR THROUGH GRILLE "CC". GRILLE LOCATED ABOVE DOOR. THERMOSTAT SHALL BE A "NEST" THERMOSTAT. ALIGN THERMOSTAT WITH SWITCH LOCATIONS. SEE ARCHITECTURAL DRAWINGS. FAN COIL UNIT -REFER TO SCHEDULE ON M5-02 AND DETAIL1/M6-02. 1 2 3 4 5 6 7 8 9 10 11 12 FCU-A 6"x6" BB 25 CFM 10"x6" AA 200 CFM 10"x6" AA 175 CFM 14"x8" 6"x6" BB 40 CFM 6"ø 4"ø F-A 10"x6" AA 200 CFM3 1 10 9 6 8 5 4 5 2 4"ø 12 T FCU-A 11 FCU-A 14"x8"6"x6" BB 40 CFM 10"x6" AA 175 CFM 10"x6" AA 175 CFM 10"x6" AA 200 CFM 6"x6" BB 25 CFM F-A 6"x6" BB 25 CFM 6"ø 4"ø4"ø 4"ø 3 1 8 9 4 5 5 T FCU-A11 2 2 10 6 12 FCU-A 14"x8"6"x6" BB 40 CFM 10"x6" AA 175 CFM 10"x6" AA 200 CFM 10"x6" AA 175 CFM F-A 5 4 5 9 10 1 3 2 2 11 FCU-A T 6"x6" BB 25 CFM 6"x6" BB 25 CFM 6 12 6"ø4"ø4"øDRYER EXHAUST LENGTHS UNIT S-A EQUIVALENT LENGTH (FT.) ALLOWABLE LENGTH (FT.)NOTES 90 NOTES: 1. ALLOWABLE LENGTH BASED UPON GE GFDN110EDWW. 2. ALLOWABLE LENGTH BASED UPON WHIRLPOOL WETLV27HW. 3. EQUIVALENT LENGTH BASED ON LENGTH OF DUCT AND NUMBER OF ELBOWS AS INDICATED ON PLAN. EACH ELBOW 5 EQUIVALENT FEET. 1,371 S-B 125 2,388 S-C 90 1,373 S-D 90 1,377 OUTSIDE AIR CALCULATIONS UNIT S-A S-B S-C S-D BREATHING ZONE (FT3)PEOPLE PROVIDED OA CFM 2 2 2 2 40 40 40 40 AIR CHANGES/ HR 0.35 CFM/ PERSON 15 15 15 15 REQUIRED OA CFM 30 30 30 30 NOTES: 1. REQUIRED OUTSIDE AIR IS BASED ON 0.35 AIR CHANGES PER HOUR OR 15 CFM PER PERSON, WHICHEVER IS GREATER. 0.35 0.35 0.35 3560 3330 2880 2635 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:20:15 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM3−01 08.14.18MECHANICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"M3-01 1 UNIT S-A PLAN SCALE: 1/4" = 1'-0"M3-01 2 UNIT S-B PLAN SCALE: 1/4" = 1'-0"M3-01 3 UNIT S-C PLAN SCALE: 1/4" = 1'-0"M3-01 4 UNIT S-D PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION DWR.R. DW DW R. R. R. DW FCU-A 10"x6" AA 150 CFM 10"x6" AA 125 CFM 10"x6" AA 175 CFM 6"x6" BB 25 CFM 10"x6" BB 100 CFM F-A 6"x6" AA 25 CFM 14"x8" ø8"6"ø4"øø8" 1 2 5 54 8 6"x6" BB 40 CFM 3 6 10 9 2 7 FCU-AT 11 12"x6" CC ø4" ø4" ø6"8"ø6"ø4"ø12 FCU-A 10"x6" AA 125 CFM 10"x6" AA 125 CFM 6"x6" BB 40 CFM 6"x6" AA 25 CFM 6"x6" BB 25 CFM 10"x6" AA 200 CFM 10"x6" BB 100 CFM14"x8"4"ø 6"ø 4"ø 1 8 6 545 F-A 10 9 3 T 11 FCU-A 7 2 2 12"x6" CC 12 FCU-A 10"x6" AA 125 CFM 10"x6" AA 125 CFM 10"x6" AA 200 CFM 6"x6" BB 25 CFM F-A 6"x6" BB 25 CFM 10"x6" AA 100 CFM 4"ø 6"ø 6"x6" BB 40 CFM 22 7 1 5 4 5 6 8 9 10 T FCU-A 11 12"x6" CC 3 14"x8"ø8"ø8" 8"ø ø4" ø4" 4"ø 12 FCU-A 10"x6" AA 100 CFM 10"x6" AA 100 CFM 10"x6" BB 75 CFM 10"x6" AA 100 CFM 10"x6" AA 75 CFM 10"x6" BB 100 CFM 10"x6" BB 25 CFM 10"x6" AA 25 CFM 6"x6" BB 40 CFM F-A 6"ø 4"ø 4"ø 4"ø 14"x8" 5 5 4 1 3 10 9 2 2 ø6" T FCU-A 11 7 12"x6" CC 12 6 GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. ADA UNITS ARE S-A, 1-B, 1-H, 2-A, AND ARE LOCATED ON R1, R2, AND R12. LAYOUTS ARE SIMILAR AND SIDEWALL DIFFUSERS SHALL BE REPLACED WITH CEILING DIFFUSERS. 3. SENSORY IMPAIRED UNITS ARE 1-H AND 2-A ON R3 AND S-A AND 1-B ON R11. KEY NOTES: 6"x4" OUTSIDE AIR DUCT TO OUTSIDE AIR SUPPLY DUCT IN CORRIDOR. UNDERCUT DOOR 1 INCH FOR TRANSFER AIR, BY OTHERS. SEE ARCHITECTURAL DRAWINGS. REFRIGERANT PIPING LINE SETS IN OPENING UP TO ROOF. SEE ARCHITECTURAL DRAWINGS FOR DRYWALL ENCLOSURE. 4"∅DRYER EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 4"∅OR 6"∅, SIZE AS NOTED ON PLAN, EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 6"∅UP FROM RANGE HOOD EXHAUST CONNECTION. PROVIDE TRANSITION TO RANGE HOOD EXHAUST CONNECTION. TRANSFER AIR DUCT WITH GRILLE, SIZE AS INDICATED; SEE DETAIL 8/M6-01. 4"∅DRYER VENT UP FROM TOP OF WALL MOUNTED DRYER BOX. DRYER BOX SHALL BE EQUAL TO IN-O-VATE TECHNOLOGIES DRYER BOX #350 WITH UPWARD EXHAUST DIRECTION COLLAR CONNECTION. DRYER EXHAUST AIR THROUGH 24X8 RETURN AIR GRILLE "CC" LOCATED ABOVE DOOR. GRILLES MUST PROVIDE A MINIMUM OF 100 SQ.IN. FREE AREA. 24X8 RETURN AIR THROUGH GRILLE "CC". GRILLE LOCATED ABOVE DOOR. THERMOSTAT SHALL BE A "NEST" THERMOSTAT. ALIGN THERMOSTAT WITH SWITCH LOCATIONS. SEE ARCHITECTURAL DRAWINGS. FAN COIL UNIT -REFER TO SCHEDULE ON M5-02 AND DETAIL1/M6-02. 1 2 3 4 5 6 7 8 9 10 11 12 DRYER EXHAUST LENGTHS UNIT 1-A EQUIVALENT LENGTH (FT.) ALLOWABLE LENGTH (FT.)NOTES 125 NOTES: 1. ALLOWABLE LENGTH BASED UPON GE GFDN110EDWW. 2. ALLOWABLE LENGTH BASED UPON WHIRLPOOL WETLV27HW. 3. EQUIVALENT LENGTH BASED ON LENGTH OF DUCT AND NUMBER OF ELBOWS AS INDICATED ON PLAN. EACH ELBOW 5 EQUIVALENT FEET. 2,3 1-B 90 1,3 1-C 90 1,3 1-D 90 1,3 OUTSIDE AIR CALCULATIONS UNIT 1-A 1-B 1-C 1-D BREATHING ZONE (FT3)PEOPLE PROVIDED OA CFM 2 2 2 2 40 40 40 40 AIR CHANGES/ HR 0.35 CFM/ PERSON 15 15 15 15 REQUIRED OA CFM 30 30 30 30 NOTES: 1. REQUIRED OUTSIDE AIR IS BASED ON 0.35 AIR CHANGES PER HOUR OR 15 CFM PER PERSON, WHICHEVER IS GREATER. 0.35 0.35 0.35 81 95 78 35 3880 4125 3905 3990 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:26:58 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM3−02 08.14.18MECHANICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"M3-02 1 UNIT 1-A PLAN SCALE: 1/4" = 1'-0"M3-02 2 UNIT 1-B PLAN SCALE: 1/4" = 1'-0"M3-02 3 UNIT 1-C PLAN SCALE: 1/4" = 1'-0"M3-02 4 UNIT 1-D PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FECDWR.DW R.R.DW R.14"x8"10"x6" AA 200 CFM 6"x6" AA 25 CFM FCU-A 4"ø 6"ø 4"ø ø4" T 12"x6" CC 1 8 9 6 10 7 3 2 2 5 5 11FCU-A 4 10"x6" AA 125 CFM 10"x6" AA 125 CFM 10"x6" BB 100 CFM 6"x6" BB 40 CFM 6"x6" BB 25 CFM ø8" 12 F-A 10"x6" AA 150 CFM 6"x6" BB 25 CFM 6"x6" BB 25 CFM 14"x8" F-A 6"x6" BB 40 CFM 10"x6" BB 100 CFM 6"ø4"ø 4"ø10"x6" AA 150 CFM FCU-A T FCU-A 1 3 10 2 2 12"x6" CC 8 6 545 ø8" ø4" 9 11 7 10"x6" AA 150 CFM ø8" 12 10"x6" AA 150 CFM 10"x6" AA 150 CFM 10"x6" AA 200 CFM F-A FCU-A 6"x6" BB 40 CFM 10"x6" BB 100 CFM 3 10 9 2 1 7 5 5 4 6 8 12"x6" CC 14"x8"6"x6" BB 25 CFM 12 T FCU-A 11 14"x8" 4"ø 4"ø ø4" 4"ø 10"x6" AA 125 CFM 10"x6" AA 125 CFM 6"x6" BB 40 CFM 6"x6" BB 25 CFM FCU-A 10"x6" AA 200 CFM 10"x6" BB 100 CFM 1 3 9 10 6 8 7 12"x6" CC 2 2 10"x8"10"x8"TFCU-A11 12 6"ø 4 5 5 6"x6" BB 25 CFM F-A GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. ADA UNITS ARE S-A, 1-B, 1-H, 2-A, AND ARE LOCATED ON R1, R2, AND R12. LAYOUTS ARE SIMILAR AND SIDEWALL DIFFUSERS SHALL BE REPLACED WITH CEILING DIFFUSERS. 3. SENSORY IMPAIRED UNITS ARE 1-H AND 2-A ON R3 AND S-A AND 1-B ON R11. KEY NOTES: 6"x4" OUTSIDE AIR DUCT TO OUTSIDE AIR SUPPLY DUCT IN CORRIDOR. UNDERCUT DOOR 1 INCH FOR TRANSFER AIR, BY OTHERS. SEE ARCHITECTURAL DRAWINGS. REFRIGERANT PIPING LINE SETS IN OPENING UP TO ROOF. SEE ARCHITECTURAL DRAWINGS FOR DRYWALL ENCLOSURE. 4"∅DRYER EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 4"∅OR 6"∅, SIZE AS NOTED ON PLAN, EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 6"∅UP FROM RANGE HOOD EXHAUST CONNECTION. PROVIDE TRANSITION TO RANGE HOOD EXHAUST CONNECTION. TRANSFER AIR DUCT WITH GRILLE, SIZE AS INDICATED; SEE DETAIL 8/M6-01. 4"∅DRYER VENT UP FROM TOP OF WALL MOUNTED DRYER BOX. DRYER BOX SHALL BE EQUAL TO IN-O-VATE TECHNOLOGIES DRYER BOX #350 WITH UPWARD EXHAUST DIRECTION COLLAR CONNECTION. DRYER EXHAUST AIR THROUGH 24X8 RETURN AIR GRILLE "CC" LOCATED ABOVE DOOR. GRILLES MUST PROVIDE A MINIMUM OF 100 SQ.IN. FREE AREA. 24X8 RETURN AIR THROUGH GRILLE "CC". GRILLE LOCATED ABOVE DOOR. THERMOSTAT SHALL BE A "NEST" THERMOSTAT. ALIGN THERMOSTAT WITH SWITCH LOCATIONS. SEE ARCHITECTURAL DRAWINGS. FAN COIL UNIT -REFER TO SCHEDULE ON M5-02 AND DETAIL1/M6-02. 1 2 3 4 5 6 7 8 9 10 11 12 DRYER EXHAUST LENGTHS UNIT 1-E EQUIVALENT LENGTH (FT.) ALLOWABLE LENGTH (FT.)NOTES 90 NOTES: 1. ALLOWABLE LENGTH BASED UPON GE GFDN110EDWW. 2. ALLOWABLE LENGTH BASED UPON WHIRLPOOL WETLV27HW. 3. EQUIVALENT LENGTH BASED ON LENGTH OF DUCT AND NUMBER OF ELBOWS AS INDICATED ON PLAN. EACH ELBOW 5 EQUIVALENT FEET. 1,3 1-F 90 1,3 1-G 90 1,3 1-H 125 2,3 OUTSIDE AIR CALCULATIONS UNIT 1-E 1-F 1-G 1-H BREATHING ZONE (FT3)PEOPLE PROVIDED OA CFM 2 2 2 2 40 40 40 40 AIR CHANGES/ HR 0.35 CFM/ PERSON 15 15 15 15 REQUIRED OA CFM 30 30 30 30 NOTES: 1. REQUIRED OUTSIDE AIR IS BASED ON 0.35 AIR CHANGES PER HOUR OR 15 CFM PER PERSON, WHICHEVER IS GREATER. 0.35 0.35 0.35 35 61 50 89 4325 3945 3815 4300 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:25:11 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM3−03 08.14.18MECHANICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"M3-03 1 UNIT 1-E PLAN SCALE: 1/4" = 1'-0"M3-03 2 UNIT 1-F PLAN SCALE: 1/4" = 1'-0"M3-03 3 UNIT 1-G PLAN SCALE: 1/4" = 1'-0"M3-03 4 UNIT 1-H PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION DW R.R.DWFECR.10"x6" AA 175 CFM 10"x6" AA 150 CFM 10"x6" AA 125 CFM 10"x6" BB 100 CFM 6"x6" BB 40 CFM 6"x6" BB 25 CFM 6"ø 4"ø 10"x8"14"x8"10"x8"4"ø1 2 3 10 9 8 6 6"x6" BB 25 CFM FCU-A 4 5 2 7 12"x6" CC 12 5 F-A 6"x6" BB 40 CFM 6"x6" BB 25 CFM TFCU-A 10"x6" AA 150 CFM 10"x6" AA 200 CFM10"x6" BB 100 CFM 10"x6" BB 125 CFM 14"x8" 6"ø 4"ø 4"ø1 3 10 9 11 6 2 5 4 5 2 FCU-A12 F-A GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. ADA UNITS ARE S-A, 1-B, 1-H, 2-A, AND ARE LOCATED ON R1, R2, AND R12. LAYOUTS ARE SIMILAR AND SIDEWALL DIFFUSERS SHALL BE REPLACED WITH CEILING DIFFUSERS. 3. SENSORY IMPAIRED UNITS ARE 1-H AND 2-A ON R3 AND S-A AND 1-B ON R11. KEY NOTES: 6"x4" OUTSIDE AIR DUCT TO OUTSIDE AIR SUPPLY DUCT IN CORRIDOR. UNDERCUT DOOR 1 INCH FOR TRANSFER AIR, BY OTHERS. SEE ARCHITECTURAL DRAWINGS. REFRIGERANT PIPING LINE SETS IN OPENING UP TO ROOF. SEE ARCHITECTURAL DRAWINGS FOR DRYWALL ENCLOSURE. 4"∅DRYER EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 4"∅OR 6"∅, SIZE AS NOTED ON PLAN, EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 6"∅UP FROM RANGE HOOD EXHAUST CONNECTION. PROVIDE TRANSITION TO RANGE HOOD EXHAUST CONNECTION. TRANSFER AIR DUCT WITH GRILLE, SIZE AS INDICATED; SEE DETAIL 8/M6-01. 4"∅DRYER VENT UP FROM TOP OF WALL MOUNTED DRYER BOX. DRYER BOX SHALL BE EQUAL TO IN-O-VATE TECHNOLOGIES DRYER BOX #350 WITH UPWARD EXHAUST DIRECTION COLLAR CONNECTION. DRYER EXHAUST AIR THROUGH 24X8 RETURN AIR GRILLE "CC" LOCATED ABOVE DOOR. GRILLES MUST PROVIDE A MINIMUM OF 100 SQ.IN. FREE AREA. 24X8 RETURN AIR THROUGH GRILLE "CC". GRILLE LOCATED ABOVE DOOR. THERMOSTAT SHALL BE A "NEST" THERMOSTAT. ALIGN THERMOSTAT WITH SWITCH LOCATIONS. SEE ARCHITECTURAL DRAWINGS. FAN COIL UNIT -REFER TO SCHEDULE ON M5-02 AND DETAIL1/M6-02. 1 2 3 4 5 6 7 8 9 10 11 12 DRYER EXHAUST LENGTHS UNIT 1-J EQUIVALENT LENGTH (FT.) ALLOWABLE LENGTH (FT.)NOTES 90 NOTES: 1. ALLOWABLE LENGTH BASED UPON GE GFDN110EDWW. 2. ALLOWABLE LENGTH BASED UPON WHIRLPOOL WETLV27HW. 3. EQUIVALENT LENGTH BASED ON LENGTH OF DUCT AND NUMBER OF ELBOWS AS INDICATED ON PLAN. EACH ELBOW 5 EQUIVALENT FEET. 1,2 1-K 125 2,3 OUTSIDE AIR CALCULATIONS UNIT 1-J 1-K BREATHING ZONE (FT3)PEOPLE PROVIDED OA CFM 2 2 40 40 AIR CHANGES/ HR 0.35 CFM/ PERSON 15 15 REQUIRED OA CFM 30 30 NOTES: 1. REQUIRED OUTSIDE AIR IS BASED ON 0.35 AIR CHANGES PER HOUR OR 15 CFM PER PERSON, WHICHEVER IS GREATER. 0.35 98 77 4235 3645 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:25:42 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM3−04 08.14.18MECHANICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"M3-04 1 UNIT 1-J PLAN SCALE: 1/4" = 1'-0"M3-04 2 UNIT 1-K PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION FEC DW R. R.R.DWR.DW6"x6" BB 25 CFM 6"x6" BB 60 CFM F-A 10"x6" AA 125 CFM 6"x6" BB 25 CFM 6"x6" BB 25 CFM 6"x6" BB 25 CFM 10"x6" AA 175 CFM 10"x6" AA 200 CFM 10"x6" BB 100 CFM 18"x8"F-A 6 1 8 45 5 2 2 3 9 10 T FCU-B11 4"ø 4"ø 6"ø4"ø 6"ø FCU-B 2 2 12 6"ø4"ø6"ø12"x6" CC 7 12"x6" CC 10"x6" AA 100 CFM 10"x6" AA 150 CFM 10"x6" AA 25 CFM 10"x6" AA 175 CFM 10"x6" AA 175 CFM F-A F-A18"x8"12"x6" CC 12"x6" CC ø4" 7 7 9 10 3 8 5 1 2 2 6 5 FCU-B T FCU-B 11 2 2 6"ø 4"ø5 10"x6" BB 25 CFM 6"x6" BB 60 CFM 6"x6" BB 25 CFM 10"x6" BB 25 CFM 8"ø4 8"ø 10"x6" BB 200 CFM 12 10"x6" AA 200 CFM 10"x6" AA 175 CFM 6"x6" BB 25 CFM 6"x6" BB 25 CFM 6"x6" AA 25 CFM 6"x6" BB 60 CFM 6"ø4"ø8 5 5 6 3 10 7 1 4 5 2 2 6"x6" BB 25 CFM F-A FCU-B 12"x6" CC T FCU-B 11 9 6"øø4" ø4" 10"x6" BB 150 CFM 7 12"x6" CC 12 10"x6" BB 100 CFM18"x8"F-A GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. ADA UNITS ARE S-A, 1-B, 1-H, 2-A, AND ARE LOCATED ON R1, R2, AND R12. LAYOUTS ARE SIMILAR AND SIDEWALL DIFFUSERS SHALL BE REPLACED WITH CEILING DIFFUSERS. 3. SENSORY IMPAIRED UNITS ARE 1-H AND 2-A ON R3 AND S-A AND 1-B ON R11. KEY NOTES: 6"x4" OUTSIDE AIR DUCT TO OUTSIDE AIR SUPPLY DUCT IN CORRIDOR. UNDERCUT DOOR 1 INCH FOR TRANSFER AIR, BY OTHERS. SEE ARCHITECTURAL DRAWINGS. REFRIGERANT PIPING LINE SETS IN OPENING UP TO ROOF. SEE ARCHITECTURAL DRAWINGS FOR DRYWALL ENCLOSURE. 4"∅DRYER EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 4"∅OR 6"∅, SIZE AS NOTED ON PLAN, EXHAUST TO WALL CAP. PROVIDE GALVANIZED VENT CAP, FACTORY PAINTED TO MATCH METAL PANELS. SEE DETAIL 5/A7-166 FOR DUCT CONFIGURATION. 6"∅UP FROM RANGE HOOD EXHAUST CONNECTION. PROVIDE TRANSITION TO RANGE HOOD EXHAUST CONNECTION. TRANSFER AIR DUCT WITH GRILLE, SIZE AS INDICATED; SEE DETAIL 8/M6-01. 4"∅DRYER VENT UP FROM TOP OF WALL MOUNTED DRYER BOX. DRYER BOX SHALL BE EQUAL TO IN-O-VATE TECHNOLOGIES DRYER BOX #350 WITH UPWARD EXHAUST DIRECTION COLLAR CONNECTION. DRYER EXHAUST AIR THROUGH 24X8 RETURN AIR GRILLE "CC" LOCATED ABOVE DOOR. GRILLES MUST PROVIDE A MINIMUM OF 100 SQ.IN. FREE AREA. 24X8 RETURN AIR THROUGH GRILLE "CC". GRILLE LOCATED ABOVE DOOR. THERMOSTAT SHALL BE A "NEST" THERMOSTAT. ALIGN THERMOSTAT WITH SWITCH LOCATIONS. SEE ARCHITECTURAL DRAWINGS. FAN COIL UNIT -REFER TO SCHEDULE ON M5-02 AND DETAIL1/M6-02. 1 2 3 4 5 6 7 8 9 10 11 12 DRYER EXHAUST LENGTHS UNIT 2-A EQUIVALENT LENGTH (FT.) ALLOWABLE LENGTH (FT.)NOTES 90 NOTES: 1. ALLOWABLE LENGTH BASED UPON GE GFDN110EDWW. 2. EQUIVALENT LENGTH BASED ON LENGTH OF DUCT AND NUMBER OF ELBOWS AS INDICATED ON PLAN. 1,2 2-B 90 1,2 2-C 90 1,2 OUTSIDE AIR CALCULATIONS UNIT 2-A 2-B 2-C BREATHING ZONE (FT3) PEOPLE PROVIDED OA CFM 3 3 3 60 AIR CHANGES/ HR 0.35 CFM/ PERSON 15 15 15 REQUIRED OA CFM 45 45 45 NOTES: 1. REQUIRED OUTSIDE AIR IS BASED ON 0.35 AIR CHANGES PER HOUR OR 15 CFM PER PERSON, WHICHEVER IS GREATER. 0.35 0.35 82 66 83 60 60 5920 5920 5540 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:26:16 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM3−05 08.14.18MECHANICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"M3-05 1 UNIT 2-A PLAN SCALE: 1/4" = 1'-0"M3-05 2 UNIT 2-B PLAN SCALE: 1/4" = 1'-0"M3-05 3 UNIT 2-C PLAN Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION MM MMSCALE:MMMMMM2" CW MAKE-UP SEE PLUMBING DRAWINGS FOR CONTINUATION SOLENOID VALVE CONTROLLED BY WATER LEVEL SENSORS DRAIN VALVE - FULL SIZE OF TOWER CONNECTION TYPICAL OVERFLOW PIPE - FULL SIZE OF TOWER CONNECTION TYPICAL 6" DRAIN PIPE TO HUB DRAIN - SEE PLUMBING DRAWINGS FOR CONTINUATION 1" CW MAKE-UP SEE PLUMBING DRAWINGS FOR CONTINUATION LEVEL 09 SCU-12-01 SCU-11-01 SCU-10-01 SCU-09-01 LEVEL 10 LEVEL 11 LEVEL 12 ISOLATION VALVE (TYP.) 3" CWS 3" CWR 3" CWS 3" CWR 3" CWS 3" CWR 6" CWR 6" CWS 6" CWR 6" CWS COOLING TOWER CT-1 10" CWR 10" CWS NC 10" CWR 8" CWS 1350 GPM 10" CWR10" CWR10" CWS8" CWR 8" CWS 10" CWRPENTHOUSE LEVEL FLOW DIAGRAM LEGEND MANUAL BUTTERFLY VALVE UNLESS NOTED OTHERWISE AUTOMATED BUTTERFLY VALVES UNLESS NOTED OTHERWISE. NORMALLY OPEN NORMALLY CLOSED CONDENSER WATER SUPPLY CONDENSER WATER RETURN PRESSURE REDUCING STATION CWS CWR PRS NO NC SWING CHECK VALVE GATE VALVE 3" CWS 3" CWR HEAT EXCHANGER HX-1 1800 GPM CWS CONDENSER WATER PUMPS P-1/P-2/P-3 P-3 IS STANDBY PUMP 675 GPM EACH 10" CWS1800 GPM 10" CWS8" CWS8" CWS8" CWRP-4 P-5 P-2 P-3 450 GPM300GPM150 GPM150 GPM 150 GPM 150 GPM 150 GPM WATER LEVEL SENSOR TYPICAL EACH BASIN EXPANSION TANK MECHANICAL ROOM RISER DIAGRAM CONDENSER WATER PUMPS P-4/P-5 /P-6 P-6 IS STANDBY PUMP 900 GPM EACH SCU-14-01 LEVEL 14 3" CWS 3" CWR 6" CWR 6" CWS 600 GPM150 GPM SCU-15-01 LEVEL 15 3" CWS 3" CWR 8" CWR 8" CWS 750 GPM150 GPM SCU-16-01 LEVEL 16 3" CWS 3" CWR 8" CWR 8" CWS 900 GPM150 GPM 1800 GPM CWS ROOF FLOW DIAGRAM 8" CWRINTERSTITIAL LEVEL 8" CWR 8" CWS 1350 GPM CWR 1350 GPM CWS 1800 GPM CWR 10" CWR NC NC 6" CWS/R 8 CWR 8" CWS/R 8" CWS/R 10" CWR P-1 MOTORIZED TWO WAY VALVE (TYP.) NC NC NC NC NC NC ERU-01 4" CWS 4" CWR 270 GPM NC 8" CWR 8" CWS TO PENTHOUSE 1350 GPM CWS&R 1320 GPM REQUIRED NO P-6 8" CWS/R 8" CWR 8" CWS TO MECHANICAL ROOM RISER 1350 GPM CWS&R NO PRS1050 GPMTYP 3 PROVIDE ISOLATION BUTTERFLY VALVES AT BOTTOM OF RISER. PROVIDE 2" DRAIN VALVE AT BOTTOM OF RETURN RISER WITH THREADED END FOR HOSE CONNECTION. AIR SEPARATOR STRAINER PRS 1 M4-01 MECHANICAL FLOW DIAGRAM NONE c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:21:40 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM4−01 08.14.18MECHANICAL CONDENSER WATER FLOW DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" LEVEL 30 − ROOF 1049’ − 6" PARAPET 1052’ − 0" LEVEL 31 − PENTHOUSE ROOF 1061’ − 9"32"x32"28"x32"22"x32"16"x32"20"x32"FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD SEE FLOOR PLAN FOR CONTINUATION TYP. FSD(2) FSD(2)26"x32"FROM OAU-01. SEE ROOF PLAN FOR CONTINUATION LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" LEVEL 30 − ROOF 1049’ − 6" PARAPET 1052’ − 0" LEVEL 31 − PENTHOUSE ROOF 1061’ − 9"32"x32"28"x32"22"x32"20"x32"FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) FSD(2) SEE FLOOR PLAN FOR CONTINUATION TYP.26"x32"FROM OAU-02. SEE ROOF PLAN FOR CONTINUATION. LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1"34"x52"MOD FSD MOD MOD MOD MOD MOD MOD FSD FSD FSD FSD FSD FSD SEE FLOOR PLAN FOR CONTINUATION TYP. FROM ERU-01. SEE FLOOR PLAN M1-17 FOR CONTINUATION FSD LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" C.8C.9 FSD 50"x30"SEE FLOOR PLAN FOR CONTINUATION TYP. TO ERU-01. SEE FLOOR PLAN M1-17 FOR CONTINUATION FSD FSD FSD FSD FSD FSD FSD FD AT SLAB FD GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. EXTERIOR OUTSIDE AIR RISERS SHALL BE INSULATED AND PROVIDED WITH WEATHERPROOF JACKET. REFER TO SPECIFICATIONS. 3. ALL OUTSIDE AIR RISERS ARE LOCATED IN RATED CHASES, SEE ARCHITECURAL DRAWINGS FOR RATING. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:20:46 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM4−02 08.14.18MECHANICAL OUTSIDE AIR RISER DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/8" = 1'-0"M4-02 1 RESIDENTIAL OA-1 SCALE: 1/8" = 1'-0"M4-02 2 RESIDENTIAL OA-2 SCALE: 1/8" = 1'-0"M4-02 3 OFFICE OA-3 SCALE: 1/8" = 1'-0"M4-02 4 OFFICE RA-1 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" LEVEL 30 − ROOF 1049’ − 6" PARAPET 1052’ − 0" LEVEL 31 − PENTHOUSE ROOF 1061’ − 9" D.1DD.0.5C.8C.9 16"x76"20"x20" K 3000 CFM F-R-01 MOD SP SP 20"x20" K 3000 CFM 20"x20" K 3000 CFM 20"x20" K 3000 CFM 16"x76"10"x76"3 LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" LEVEL 30 − ROOF 1049’ − 6" PARAPET 1052’ − 0" LEVEL 31 − PENTHOUSE ROOF 1061’ − 9" 2.8 20"x20" K 3000 CFM FROM F-R-02. SEE ROOF PLAN FOR CONTINUATION SP STATIC PRESSURE CONTROLLER TO CONTROL FAN SPEED TO MAINTAIN PRESET STAIRWELL PRESSURE. TYP. SP16"x76"14"x76"10"x76"20"x20" K 3000 CFM 20"x20" K 3000 CFM 20"x20" K 3000 CFM LEVEL 2 − P2 735’ − 9" LEVEL 3 − P3 746’ − 9" LEVEL 4 − P4 757’ − 9" LEVEL 5 − P5 768’ − 1" LEVEL 6 − P6 778’ − 1" LEVEL 7 − P7 788’ − 1" LEVEL 8 − P8 798’ − 1" LEVEL 9 − O1 811’ − 3" LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10"20"x64"36"x20" K 3000 CFM 36"x20" K 3000 CFM 36"x20" K 3000 CFM 36"x20" K 3000 CFM 36"x20" K 3000 CFM FROM F-17-01. SEE M1-17 CONTINUATION SP SP STATIC PRESSURE CONTROLLER TO CONTROL FAN SPEED TO MAINTAIN PRESET STAIRWELL PRESSURE. TYP. SP LEVEL 8 − P8 798’ − 1" LEVEL 9 − O1 811’ − 3" LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1" C.7.1 C.8C.9 20"x20" K 2330 CFM 12"x48"SP STATIC PRESSURE CONTROLLER TO CONTROL FAN SPEED TO MAINTAIN PRESET STAIRWELL PRESSURE. TYP. SP 20"x20" K 2330 CFM 20"x20" K 2330 CFM FROM F-08-02. SEE M1-08 FOR CONTINUATION. B LEVEL 3 − P3 746’ − 9" LEVEL 4 − P4 757’ − 9" LEVEL 5 − P5 768’ − 1" LEVEL 6 − P6 778’ − 1" LEVEL 7 − P7 788’ − 1" LEVEL 8 − P8 798’ − 1" LEVEL 9 − O1 811’ − 3" A.6.1A.3 20"x20" K 2000 CFM 30"x8" K 1000 CFM TYP.212"x48"F-02-01 SP STATIC PRESSURE CONTROLLER TO CONTROL FAN SPEED TO MAINTAIN PRESET STAIRWELL PRESSURE. TYP. SP 20"x20" K 2000 CFM 20"x20" K 2000 CFM GENERAL NOTES: 1. SEE DRAWING M0-01 FOR GENERAL NOTES AND LEGENDS. 2. EXTERIOR STAIR PRESSURIZATION DUCTWORK WRAPPED WITH 2-HOUR RATED FIRE WRAP AND PROVIDED WITH WEATHERPROOF JACKET. FIRE WRAP MUST ENCASE THE DUCTWORK UNTIL IT REACHES THE RATED CHASE. REFER TO SPECIFICATIONS. 3. STAIR PRESSURIZATION DUCTWORK SHALL BE FULL SIZE OF FAN DISCHARGED CONNECTION. TRANSITION TO SIZE NOTED. 4. ALL STAIR PRESSURIZATION AIR RISERS ARE LOCATED WITHIN RATED STAIR ENCLOSURE, SEE ARCHITECTURAL DRAWINGS FOR RATING. 5. INTERLOCK MOTOR OPERATED DAMPER WITH ASSOCIATED FAN WITHIN STAIR PRESSURIZATION DUCTWORK. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:21:20 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM4−03 08.14.18MECHANICAL STAIR PRESSURIZATION DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/8" = 1'-0"M4-03 1 STAIR PRESSURIZATION RISER ST-1/A SCALE: 1/8" = 1'-0"M4-03 2 STAIR PRESSURIZATION RISER ST-2/A SCALE: 1/8" = 1'-0"M4-03 3 STAIR PRESSURIZATION RISER ST-1/B SCALE: 1/8" = 1'-0"M4-03 4 STAIR PRESSURIZATION RISER ST-2/B SCALE: 1/8" = 1'-0"M4-03 5 STAIR PRESSURIZATION RISER ST-2/C Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:24:10 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM5−01 08.14.18MECHANICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 COOLING TOWER SCHEDULE MARK SERVES TYPE FAN HP KW CONDENSER WATER COLD SIDE BASIS OF DESIGN "EVAPCO"NOTESEWT LWT GPM WB CT-01 OFFICE COOLING INDUCED DRAFT TWO (2) AT 20 FOUR (4) AT 4.0 85 95 1800 78 USS 293-K24 1 THRU 8 DIFFUSER, REGISTER, AND GRILLE SCHEDULE MARK TYPE BASIS OF DESIGN MODEL DESCRIPTION AA APARTMENT SIDEWALL SUPPLY REGISTER USAIRE V4004D EXTRUDED ALUMINUM CONSTRUCTION, FACE SIZE AND CFM AS NOTED, DOUBLE DEFLECTION, 2/3" FIN SPACING, FRONT BLADES PARALLEL TO SHORT DIMENSION, FLUSH INSTALLATION, SIDEWALL APPLICATION. PROVIDE WITH FACE OPERABLE DAMPER. FINISH AS APPROVED BY ARCHITECT. BB APARTMENT CEILING SUPPLY REGISTER USAIRE LS4D ROLLED FORMED ALUMINUM CONSTRUCTION, FACE SIZE AND CFM AS NOTED, ADJUSTABLE CURVED BLADES SET AT 15/16" CENTERS,FOUR WAY PATTERN, CEILING APPLICATION. PROVIDE WITH FACE OPERABLE DAMPER. FINISH AS APPROVED BY ARCHITECT. CC APARTMENT SIDEWALL RETURN/TRANSFER GRILLE USAIRE RHE ROLL-FORMED ALUMINUM CONSTRUCTION, HORIZONTAL FIXED BLADES AT 45 DEGREES, 2/3" BLADE SPACING. FINISH AS APPROVED BY ARCHITECT. A ARCHITECTURAL CEILING DIFFUSER SQUARE PLAQUE TITUS OMNI-AA 24X24 OR 12X12 FACE AS SHOWN, NECK SIZE (NS) AND CFM AS NOTED. BORDER TYPE TO MATCH CEILING TYPE IN ARCHITECTURAL REFLECTED CEILING PLAN. HEAVY GUAGE ALUMINUM FACE PANEL THAT CAPTURES A SECONDARY HEAVY GUAGE ALUMINUM PANEL. PROVIDE OPPOSED BLADE DAMPER IN DIFFUSER FACE FOR DIFFUSERS INSTALLED IN INACCESSIBLE CEILINGS. FINISH AS APPROVED BY ARCHITECT. B EGGCRATE RETURN GRILLE TITUS 50F FACE SIZE (FS) AS NOTED. BORDER TYPE AS REQUIRED BY ARCHITECTURAL REFLECTED CEILING PLAN. 1/2"X1/2"X1/2" ALUMINUM GRID WITH HEAVY EXTRUDED ALUMINUM CONSTRUCTION FOR BORDER. FINISH AS APPROVED BY ARCHITECT. C EGGCRATE RETURN AIR/EXHAUST REGISTER TITUS 50F FACE SIZE (FS) 24X24, 24X12, 12X12, AS NOTED. NECK SIZE = FACE SIZE - 2" FOR DUCTWORK CONNECTION. BORDER TYPE AS REQUIRED BY ARCHITECTURAL REFLECTED CEILING PLAN. 1/2"X1/2"X1/2" ALUMINUM GRID, HEAVY EXTRUDED ALUMINUM CONSTRUCTION FOR BORDER. PROVIDE FACE OPERABLE DAMPER ON EXHAUST REGISTERS. FINISH AS APPROVED BY ARCHITECT. D PLENUM SLOT SUPPLY DIFFUSER TITUS TBDI-80 TWO-SLOT DIFFUSER (1"SLOT EACH), LENGTH AS NOTED, INLET SIZE AND CFM AS NOTED ON THE DRAWING, WITH INSULATED PLENUM AND ADJUSTABLE GASKETED BLADE PATTERN CONTROLLER. PROVIDE FACE OPERABLE DAMPER FOR DIFFUSERS IN INACCESSIBLE CEILINGS. PROVIDE BORDER TYPE AS REQUIRED FOR CEILING APPLICATION. FINISH AS APPROVED BY ARCHITECT. E HIGH CAPACITY, HIGH THROW, LINEAR SUPPLY AIR SLOT TITUS FL-10 1-SLOT LINEAR DIFFUSER (1" SLOT) WITH END CAPS, LENGTH AS NOTED WITH HIGH THROW PATTERN, MAXIMUM 63 CFM/LINEAR FOOT. BORDER TYPE 22 FOR GYPSUM MUD IN CEILING. PROVIDE INSULATED PLENUM AS NOTED. DAMPER SHALL BE INSTALLED IN DUCTWORK BRANCH TO SLOT AND SHALL BE ACCESSIBLE THROUGH FACE OF SLOT. F HIGH CAPACITY, JET THROW, LINEAR SUPPLY AIR SLOT TITUS FL-10 1-SLOT LINEAR DIFFUSER (1" SLOT) WITH END CAPS, LENGTH AS NOTED WITH JET THROW PATTERN, MAXIMUM 100 CFM/LINEAR FOOT. BORDER TYPE 22 FOR GYPSUM MUD IN CEILING. PROVIDE 4'-0" INSULATED PLENUM, NECK SIZE AS NOTED, QUANTITY AS NOTED. DAMPER SHALL BE INSTALLED IN DUCTWORK BRANCH TO SLOT AND SHALL BE ACCESSIBLE THROUGH FACE OF SLOT. PORTION OF SLOT NOT USED SHALL BE BLANKED OFF. G LINEAR RETURN AIR SLOT TITUS FBRI-10 1-SLOT LINEAR DIFFUSERS (1" SLOT), LENGTH AS NOTED WITH INSULATED RETURN AIR SHIELD. BORDER TYPE 22 FOR GYPSUM MUD IN CEILING. H SIDEWALL EXHAUST REGISTER TITUS 350 FL FACE SIZE (FS) AS NOTED. BORDER TYPE AS REQUIRED FOR MOUNTINNG. ALUMINUM CONSTRUCTION WITH ALUMINUM BLADES. FRONT BLADES SHALL BE PARALLEL TO THE LONG DIMENSION AND SPACED 3/4" ON CENTERS WITH A 35° DEFLECTION ANGLE. PROVIDE FACE OPERABLE OPPOSED BLADE VOLUME DAMPER. FINISH AS APPROVED BY THE ARCHITECT. J SIDEWALL TRANSFER REGISTER TITUS 350 FL FACE SIZE (FS) AS NOTED. BORDER TYPE AS REQUIRED FOR MOUNTINNG. ALUMINUM CONSTRUCTION WITH ALUMINUM BLADES. FRONT BLADES SHALL BE PARALLEL TO THE LONG DIMENSION AND SPACED 3/4" ON CENTERS WITH A 35° DEFLECTION ANGLE. FINISH AS APPROVED BY ARCHITECT. K SIDEWALL SUPPLY AIR REGISTER TITUS 300 FS FACE SIZE (FS) AS NOTED. BORDER TYPE AS REQUIRED FOR MOUNTINNG. ALUMINUM CONSTRUCTION WITH ALUMINUM BLADES. INDIVIDUALLY ADJUSTABLE DOUBLE DEFLECTION BLADES SPACED ON 3/4" CENTERS. FRONT BLADES SHALL BE PARALLEL TO THE SHORT DIMENSION. FINISH AS APPROVED BY THE ARCHITECT. L LINER FLOOR GRILLE PRICE LFG SIZE OF GRILLE SHAL MATCH DIMENSIONS OF TRENCH HEATER. CONTINUOUS MANDREL CORE FLOOR GRILLE WITH END CAPS, NARROW BAR SPACING, CORE 15A, 0 DEGREE DEFLECTION. REMOVEABLE CORE AND CONCEALED MOUNTING BRACKET. OFFICE LOBBY SHALL HAVE BORDER TYPE 187 AND RESIDENTIAL LOBBY SHALL HAVE BORDER TYPE 125. COLOR AND FINISH SHALL BE SELECTED AND APPROVED BY THE ARCHITECT. DUCTLESS SPLIT FAN COIL/CONDENSING UNIT SCHEDULE MARK SERVES TYPE SUPPLY FAN COOLING CAPCITY HEATING CAPACITY BASIS OF DESIGN "MITSUBISHI" UNO NOTESCFM OA CFM ESP HP DX COIL HEAT PUMP FAN COIL UNIT CONDENSING UNITTOTAL (MBH) SENSIBLE (MBH)EAT (DB/WB) SEER CAPACITY (MBH)HSPF/COP DFCU-01-01 MAIN ELECTRICAL ROOM COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 10, 11 DFCU-01-02 TELECOM ROOM COOLING 705 0 0 24.0 18.48 75/62.5 21.4 NA NA PKA-A242KA7 PUY-A24NKA7 1 THRU 8, 10, 11 DFCU-01-03 FIRE COMMAND CENTER HEAT PUMP 370 0 0 18.0 12.42 75/62.5 18.5 19.0 10.2/4.26 PKA-A18HA7 PUZ-A18NKA7 1 THRU 7, 11 DFCU-03-02 ELECTRICAL ROOM PARKING DECK COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 10, 11 DFCU-06-02 ELECTRICAL ROOM PARKING DECK COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 11 DFCU-07-02 DOG WASH HEAT PUMP 370 0 0 12.0 9.72 75/62.5 20.8 14.0 10.2/4.31 PKA-A12HA7 PUZ-A12NKA7 1 THRU 7, 11 DFCU-07-03 GARAGE ELEVATOR MACH SHAFT COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 10, 11 DFCU-08-02 ELECTRICAL ROOM PARKING DECK COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 10, 11 DFCU-17-01 OFFICE ELEVATOR MACH SHAFT COOLING 700 0 0 NOMINAL 19.3 17.8 75/62.5 14.0 NA NA CARRIER 40MKCB22B-3 CARRIER AHA424A003 1 THRU 6, 8, 9, 11 DFCU-17-02 OFFICE ELEVATOR MACH SHAFT COOLING 700 0 0 NOMINAL 19.3 17.8 75/62.5 14.0 NA NA CARRIER 40MKCB22B-3 CARRIER AHA424A003 1 THRU 6, 8, 9, 11 DFCU-R-01 APARTM ELEV MACH SHAFT COOLING 705 0 0 24.0 18.48 75/62.5 21.4 NA NA PKA-A242KA7 PUY-A24NKA7 1 THRU 8, 11 DFCU-R-02 APARTM ELEV MACH SHAFT COOLING 370 0 0 12.0 9.72 75/62.5 20.8 NA NA PKA-A12HA7 PUY-A12NKA7 1 THRU 8, 11 DFCU-XX-01 RESID ELEV LOBBY P2 THRU P8 (7 TOTAL) HEAT PUMP 370 0 0 12.0 9.72 75/62.5 20.8 14.0 10.2/4.31 PKA-A12HA7 PUZ-A12NKA7 1 THRU 7, 11 FAN SCHEDULE MARK SERVES TYPE FAN MOTOR BASIS OF DESIGN "MANUFACTURER"NOTESCFM ESP HP DRIVE F-01-01 GENERATOR ROOM IN LINE FAN 2000 0.25 1/4 BELT COOK 120 SQN-B 1, 5, 7, 9, 11, 19, 21 F-01-02 PUMP ROOM IN LINE FAN 1200 0.25 1/4 BELT COOK 120 SQN-B 1, 5, 7, 9, 11, 19, 21 F-01-03 LOADING DOCK IN LINE FAN 350 0.5 1/4 BELT COOK 70 SQN-B 1, 5, 7, 9, 13, 21 F-01-04 SINGLE TOILET/JANITOR CLOSET IN LINE FAN 150 0.5 1/6 BELT COOK 60 SQN-B 1, 5, 7, 9, 13, 21 F-01-05 EMERGENCY ELECTRICAL ROOM IN LINE FAN 200 0.5 1/6 BELT COOK 70 SQN-B 1, 5, 7, 9, 16, 21 F-01-06 OA FCU-01-01,02 IN LINE FAN 400 0.5 1/6 BELT COOK 80 SQN-B 1, 5, 7, 17, 21 F-01-07 TRASH ROOM IN LINE FAN 1500 0.5 1/2 BELT COOK 120 SQN-B 1, 5, 7, 9, 15, 21 F-02-01 STAIR PRESS #2 GARAGE VANE AXIAL IN LINE 8000 0.75 3 BELT COOK 24AFBV-C 1, 3, 6, 8, 12, 21 F-07-01 DOG WASH IN LINE FAN 150 0.25 1/6 BELT COOK 70 SQN-B 1, 5, 7, 14, 19, 21 F-08-01 STAIR PRESS #2 OFFICE VANE AXIAL IN LINE 7000 0.75 2 BELT COOK 24AFBV-C 1, 3, 7, 8, 12, 21 F-17-01 STAIR PRESS #1 OFFICE/GARAGE VANE AXIAL IN LINE 15000 1.0 7.5 BELT COOK 28AFBV-C 1, 3, 6, 8, 12, 21 F-17-02 POOL CHEMICAL INTAKE FAN IN LINE FAN 200 0.50 1/6 BELT COOK 70 SQN-B 1, 5, 7, 9, 15, 18, 21 F-17-03 POOL CHEMICAL EXHAUST FAN IN LINE FAN 200 0.50 1/6 BELT COOK 70 SQN-B 1, 5, 7, 15, 18, 20, 21 F-18-01 AMENITY POOL SINGLE TOILET CABINET 70 0.25 30.4W DIRECT COOK GC-148 1, 4, 13, 21 F-18-02 AMENITY TOILETS IN LINE FAN 200 0.5 1/6 DIRECT COOK 70 SQN-B 1, 5, 7, 9, 15, 21 F-A APARTMENT TOILETS CABINET 50 0.25 0.13 DIRECT DELTA BREEZE SLM70 1, 4, 13, 21 F-PH-01 PENTHOUSE VENTILATION IN LINE FAN 1200 0.25 1/4 BELT COOK 120 SQN-B 1, 5, 7, 9, 11, 19, 21 F-R-01 STAIR PRESSURIZATION #1 VANE AXIAL IN LINE 12000 1.0 5 BELT COOK 28AFBV-C 1, 2, 8, 12, 21 F-R-02 STAIR PRESSURIZATION #2 VANE AXIAL IN LINE 12000 1.0 5 BELT COOK 28AFBV-C 1, 2, 8, 12, 21 F-XX-01 ELECTRICAL ROOMS - OFFICE IN LINE FAN 250 0.25 1/6 BELT COOK 70 SQN-B 1, 5, 7, 11, 19, 21 HEAT EXCHANGER SCHEDULE MARK SERVES TYPE HOT SIDE COLD SIDE BASIS OF DESIGN "SONDEX"NOTESEWT LWT GPM PD (FT) EWT LWT GPM PD (FT) HX-01 PENTHOUSE CONDENSER WATER PLATE & FRAME 98 88 1350 6.9 85 95 1800 11.6 A67-IS10-276-TMTL78 1, 2 HEAT EXCHANGER NOTES: 1. PROVIDE HOUSEKEEPING PAD. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. DUCTLESS SPLIT FAN COLI/CONDENSING UNIT NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. COOLING CAPACITY AT SCHEDULED CONDITIONS. CONDENSING UNIT SHALL BE RATED FOR 95 °F. 3. CONDENSING UNIT ON THE ROOF SHALL BE SUPPORTED AS NOTED ON DETAIL 5/M6-02. CONDENSING UNIT IN THE PARKING DECK SHALL BE SUPPORTED ON NEOPRENE PADS. REFER TO ARCHITECTURAL DRAWINGS. 4. UNITS SHALL BE WALL MOUNTED 8'-0" ABOVE THE FINISHED FLOOR OR AS NOTED ON THE DRAWINGS. 5. PROVIDE DIGITAL THERMOSTAT, REMOTE MOUNTED. 6. ROUTE CONDENSATE, FULL SIZE, TO NEAREST FLOOR DRAIN OR HUB DRAIN. SEE PLUMBING DRAWING FOR EXACT LOCATION. 7. INDOOR UNITS RECEIVE POWER FROM OUTDOOR UNITS THROUGH FIELD SUPPLIED INTERCONNECTED WIRING, REFER TO ELECTRICAL DRAWINGS. 8. PROVIDE LOW AMBIENT CONTROL DOWN TO 10 °F. 9. UNIT SHALL BE CAPABLE OF REFRIGERANT LINE LENGTHS UP TO 200 FT. PROVIDE POWER TO BOTH INDOOR AND OUTDOOR UNIT SEPARATELY, SEE ELECTRICAL DRAWINGS. 10. PROVIDE UNIT MOUNTED CONDENSATE PUMP. 11. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FAN NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. PROVIDE ROOF SUPPORT TO MATCH SLOPE, MOTOR OPERATED DAMPER, DISCONNECT SWITCH AND VFD. 3. PROVIDE MOTOR OPERATED DAMPER, DISCONNECT SWITCH AND VFD. 4. PROVIDE INTEGRAL GRILLE, BACKDRAFT DAMPER, SPEED CONTROLLER MOUNTED AT FAN, DISCONNECT SWITCH AND STARTER. 5. PROVIDE BACKDRAFT DAMPER, SPEED CONTROLLER MOUNTED AT FAN, DISCONNECT SWITCH AND STARTER. 6. FAN SHALL BE FLOOR MOUNTED FROM FIELD FABRICATED SUPPORTS WITH NEOPRENE ISOLATION PADS UNDER FAN. 7. FAN SHALL BE SUSPENDED FROM STRUCTURE WITH VIBRATION ISOLATION HANGERS. 8. FAN SHALL BE INTERLOCKED WITH MOTOR OPERATED DAMPER. 9. FAN SHALL BE INTERLOCKED WITH INTAKE MOTOR OPERATED DAMPER. 10. FAN SHALL BE CONTROLLED BY A WALL MOUNTED SMOKE DETECTOR. 11. FAN SHALL BE CONTROLLED BY AN ADJUSTABLE LINE VOLTAGE THERMOSTAT. 12. FAN SHALL BE CONTROLLED BY THE FIRE CONTROL SYSTEM. 13. FAN SHALL BE CONTROLLED BY A WALL SWITCH. 14. FAN SHALL BE CONTROLLED BY WALL SWITCH WITH 15 MINUTE OFF-DELAY AFTER THE LIGHTS ARE TURNED OFF. 15. FAN SHALL RUN CONTINUOUSLY. 16. WHEN FAN IS ENERGIZED, FAN F-01-06 SHALL BE DE-ENERGIZED. 17. FAN SHALL BE ENERGIZED WHEN EITHER FCU-01-01 OR FCU-01-02 IS RUNNING AND IN THE OCCUPIED MODE. FAN SHALL NOT RUN IN THE UNOCCUPIED MODE. 18. FAN F-17-02 AND F-17-03 SHALL BE INTERLOCKED TO RUN SIMULTANEOUSLY. 19. PROVIDE PROTECTIVE SCREEN ON INLET OF FAN. 20. FAN SHALL BE CORROSION RESISTANT PER NCMC503.4. 21. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. COOLING TOWER NOTES: 1. PROVIDE 3-PROBE WATER LEVEL CONTROL PACKAGE FOR EACH CELL. 2. PROVIDE CONTACTOR FOR HEATER PACKAGE. 3. PROVIDE INVERTER DUTY FAN MOTOR. 4. PROVIDE FAN MOTOR(S) WITH VARIABLE FREQUENCY DRIVE. 5. PROVIDE LADDER, 3 FT LADDER EXTENSION, LOW SOUND FAN, AND VIBRATION SWITCH. 6. STRUCTURAL SUPPORT FOR TOWER SAHLL BE DESIGNED BY THE STRUCTURAL ENGINEER. 7. TOWER IS A TWO (2) CELL TOWER. PROVIDE INDEPENDENT CELL OPERATION WITH FLUME BOX PLATE, SUCTION MAKEUP, DRAIN AND OVERFLOW. 8. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:24:34 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM5−02 08.14.18MECHANICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 OUTSIDE AIR UNIT WITH GAS HEAT SCHEDULE MARK SERVES TYPE SUPPLY FAN COOLING CAPACITY HOT GAS REHEAT HEATING CAPACITY UNIT LAT (DB/WB) BASIS OF DESIGN "DAIKIN"NOTESCFM ESP HP DX COIL CAPACITY (MBH) EAT/LAT GAS HEAT TOTAL (MBH) SENSIBLE (MBH) EAT (DB/WB) LAT (DB/WB)INPUT (MBH) OUTPUT (MBH)EAT/LAT OAU-01 APARTMENT VENTILATION HOT GAS REHEAT 10000 2.0 7.5 835.3 385.2 88/77 52.8/52.8 186.9 52.8/70 812.5 650 17.0/76.9 54.2/53.3 RPS068D 1 THRU 5 OAU-02 APARTMENT VENTILATION HOT GAS REHEAT 10000 2.0 7.5 835.3 385.2 88/77 52.8/52.8 186.9 52.8/70 812.5 650 17.0/76.9 54.2/53.3 RPS068D 1 THRU 5 HOOD SCHEDULE MARK SERVES TYPE BASIS OF DESIGN "COOK" CFM SP NOTES H-01-01 GENERATOR ROOM INTAKE 24 PR 2000 .05 1, 2, 3 POWERED INDUCTION UNIT SCHEDULE MARK SERVES TYPE PRIMARY AIR FAN HEATING (KW) BASIS OF DESIGN "TITUS" NOTESCFM MAX CFM MIN INLET SIZE CFM ESP HP PIU-XX-01 OFFICE CORE SERIES 800 150 8 800 0.2 1/4 '-- DTFS 1, 2, 3, 5, 6 PIU-XX-02 OFFICE NORTH PARALLEL 1200 230 10 600 0.2 1/4 6 DTQP 1 THRU 5 PIU-XX-03 OFFICE EAST PARALLEL 1200 230 10 600 0.2 1/4 6 DTQP 1 THRU 5 PIU-XX-04 OFFICE SOUTH PARALLEL 1200 230 10 600 0.2 1/4 6 DTQP 1 THRU 5 PIU-XX-05 OFFICE WEST PARALLEL 1200 230 10 600 0.2 1/4 6 DTQP 1 THRU 5 PUMP SCHEDULE MARK SERVES TYPE MOTOR PUMP BASIS OF DESIGN "BELL & GOSSETT"NOTESHP RPM GPM PD (FT) P-01 OFFICE CWSR LOOP END SUCTION 30 1800 675 110 e-1510 4GC 1 THRU 5, 7 P-02 OFFICE CWSR LOOP END SUCTION 30 1800 675 110 e-1510 4GC 1 THRU 5, 7 P-03 OFFICE CWSR LOOP END SUCTION 30 1800 675 110 e-1510 4GC 1 THRU 5, 7 P-04 TOWER CWSR LOOP DOUBLE SUCTION SPLIT CASE 20 1200 900 60 VSX-VSCS 6x8x13.5B 1 THRU 7 P-05 TOWER CWSR LOOP DOUBLE SUCTION SPLIT CASE 20 1200 900 60 VSX-VSCS 6x8x13.5B 1 THRU 7 P-06 TOWER CWSR LOOP DOUBLE SUCTION SPLIT CASE 20 1200 900 60 VSX-VSCS 6x8x13.5B 1 THRU 7 SPLIT SYSTEM FAN COIL/CONDENSING UNIT SCHEDULE MARK SERVES TYPE SUPPLY FAN COOLING CAPCITY HEATING CAPACITY BASIS OF DESIGN "GOODMAN" NOTESCFM OA CFM ESP HP DX COIL ELECTRIC HEAT HEAT PUMP FAN COIL UNIT CONDENSING UNITTOTAL (MBH) SENSIBLE (MBH)EAT (DB/WB) SEER CAPACITY (KW)STEPS CAPACITY (MBH)HSPF FCU-01-01 OFFICE LOBBY VERTICAL 1600 200 0.5 3/4 45.1 34.8 77.1/64.2 14.5 15 2 45.06 3.82 FX4DNF049L00 25HCE 1, 2, 4, 5, 7 THRU 12, 14,16 FCU-01-02 OFF LOBBY INTERIOR VERTICAL 1600 200 0.5 3/4 45.1 34.8 77.1/64.2 14.5 8 2 45.06 3.82 FX4DNF049L00 25HCE 1, 2, 4, 5, 7 THRU 12, 14, 16 FCU-A STUDIO AND 1 BEDROOM VERTICAL 600 40 0.5 1/3 15.8 13.1 75/62.5 14 5 1 10 8.2 AWUF190816 GSZ140191 1, 2, 3, 5, 6, 8, 9, 10, 12 THRU 16 FCU-B 2 BEDROOM VERTICAL 800 60 0.5 1/3 20.7 17.0 75/62.5 14 8 2 13 8.2 AWUF250815 GSZ140251 1, 2, 3, 5, 6, 8, 9, 10, 12 THRU 16 WATER COOLED ENERGY RECOVERY UNIT SCHEDULE MARK SERVES TYPE SUPPLY FAN EXHAUST FAN COOLING CAPACITY HEATING CAPACITY CONDENSER WATER UNIT LAT (DB/WB) BASIS OF DESIGN "DAIKIN"NOTESCFM ESP (") HP CFM ESP(") HP HEAT WHEEL DX COIL HEAT WHEEL ELECTRIC HEAT EWT (°F) LWT (°F) GPM PD (FT)TOTAL (MBH) EAT (DB/WB) LAT (DB/WB) TOTAL (MBH) SENSIBLE (MBH) EAT (DB/WB) LAT (DB/WB) TOTAL (MBH) LAT (DB/WB)kW STEPS ERU-01 OFFICE VENTILATION WATER COOLED WHEEL 21000 2.0 1.5 AT120V, 20 AT V480/3 16800 2.0 2@7.5 628.3 88.0/77.0 80.3/70.1 1090.4 607.0 80.3/70.1 53.9/53.9 1040.0 49.0/40.6 80 AT 480/3 6.0 88 98 267 10.8 55.8/54.5 CAC0322GVHM AND SWP088HSL 1 THRU 3 WATER COOLED INDOOR SELF CONTAINED UNIT SCHEDULE MARK SERVES TYPE SUPPLY FAN COOLING CAPACITY BASIS OF DESIGN "CARRIER"NOTESCFM PRETREATED OA CFM ESP HP DX COIL WATER ECONOMIZER TOTAL (MBH) SENSIBLE (MBH) EAT (DB/WB) LAT (DB/WB) EWT LWT GPM PD (FT) SYSTEM PD (FT)TOTAL WE SENSIBLE WE LAT WE (DB/WB)EWT WE LWT WE GPM WE PD WE SCU-XX-01 OFFICE HVAC UNIT VAV 17500 3000 3.0 2 AT 7.5 617.2 478.4 75/62.5 50 88 98 150 13.6 34.2 347.7 261.9 61.1/55.8 55 60 150 20.6 50BVW054 1 THRU 12 EXPANSION TANK SCHEDULE MARK SERVES TYPE SYSTEM VOLUME BASIS OF DESIGN "BELL & GOSSETT" NOTES ET-01 PENTHOUSE EXPANSION TANK BLADDER 1050 GALLONS B-300 1, 2, 3 ELECTRIC HEATER SCHEDULE MARK SERVES TYPE KW BASIS OF DESIGN NOTES EH-01 STAIRS, EXT DOORS, CORRIDORS AND DOORS WALL HEATER 3.0 QMARK AWH4307F 1, 2, 3, 7 EH-02 NON CONDITIONED SPACES UNIT HEATER 5 QUMARK MUH0571 1, 2, 4, 7 EH-03 LOADING DOCK, P8 CEILING, AMENITY PATIO CEILING PLENUM HEATER 1.9 QMARK CHPR25 1, 2, 4, 7 EH-04 P2 THRU P6 PARKING ELEVATOR LOBBY SURFACE MOUNTED HEATER 3.0 QMARK CDF547 1, 2, 5, 7 EH-05 OFFICE LOBBY - 3 SECTIONS FOR TOTAL LENGTH 20FT TRENCH HEATER 8' AT 2.0, 4'.0 AT 1.0, 8' AT 2.0 PRICE LFGH-RC 1, 2, 6, 7 EH-06 OFFICE LOBBY - 1 SECTION FOR TOTAL LENGTH 4FT TRENCH HEATER 4' AT 1.0 PRICE LFGH-RC 1, 2, 6, 7 EH-07 RESIDENTIAL LOBBY - 1 SECTION FROR TOTAL LENGTH 4 FT TRENCH HEATER 4' AT 1.0 PRICE LFGH-RC 1, 2, 6, 7 EH-08 RESIDENTIAL LOBBY - 2 SECTIONS FOR TOTAL LENGTH 12FT TRENCH HEATER 6' AT 1.5, 6' AT 1.5 PRICE LFGH-RC 1, 2, 6, 7 EH-09 OFFICE SHELL 5 FLOORS PLENUM HEATER 5.0 MARKEL P3P5705T 1, 2, 4, 7 OUTSIDE AIR UNIT WITH GAS HEAT NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. COOLING CAPACITY AT CONDITIONS INDICATED. CONDENSING SECTION SHALL BE RATED FOR 105°F. 3. PROVIDE FACTORY INSULATED ROOF CURB TO ACCOMMODATE ROOF SLOPE. 4. UNIT SHALL HAVE HOT GAS REHEAT COIL. 5. REFER TO SPECIFICATIONS FOR ADDITIONAL UNIT REQUIREMENTS. WATER COOLED ENERGY RECOVERY UNIT NOTES: 1. PROVIDE HOUSE KEEPING PAD. 2. ERU CONSISTS OF TWO SECTIONS CONNECTED BY DUCTWORK. FIRST SECTION: FILTERS, HEAT WHEEL, ELECTRIC HEATING COILS, AND RETURN AIR FANS. SECOND SECTION: 100% OUTSIDE AIR SELF CONTAINED UNIT. 3. REFER TO SPECIFICATIONS FOR ADDITIONAL UNIT REQUIREMENTS. WATER COOLED INDOOOR SELF CONTAINED UNIT NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. UNIT SHALL BE HIGH EFFICIENY TYPE WITH MICROPROCESSOR CONTROLS AND BAC-NET INTERFACE COMPATABLE WIT BAS. 3. PROVIDE SINGLE POINT CONNECTION AND BUILT-IN DISCONNECT. 4. PROVIDE TWO (2) SETS OF 2" FILTERS FOR UNIT. MINIMUM EFFICIENCY HALL BE 11 MERV AT 500 FPM MAXIMUM VELOCITY. 5. PROVIDE SMOKE DETECTOR AT RETURN TO UNIT. DETETORS SHALL BE ACCESSIBLE. DETECTORS SHALL BE PROVIDED AND INSTALLED BY MECHCANICAL CONTRACTOR. WIRING TO FIRE ALARM PANEL TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 6. ROUTE CONDENSATE FULL SIZE OF UNIT CONNECTION TO NEAREST FLOOR DRAIN OR HUB DRAIN. SEE PLUMBING DRAWINGS FOR EXACT LOCATION. 7. PROVIDE 4 ROW COOLING COIL. FACE VELOCITY ON COOLING COIL = 500 FPM. 8. PROVIDE VARIABLE FREQUENCY DRIVE AND DISCONNECT. 9. REFER TO SPECIFICATIONS FOR ADDITIONAL UINT REQUIREMENTS. 10. PRETREATED OUTSIDE AIR PROVIDED FROM ERU UNIT. 11. PROVIDE HOUSEKEEPING PAD. 12. REFER TO SPECIFICATIONS FOR ADDITIONAL UNIT REQUIREMENTS. SPLIT SYSTEM FAN COIL UNIT NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. COOLING CAPACITY AT CONDITIONS INDICATED. CONDENSING UNITS ON ROOF SHALL BE RATED FOR 105°F. CONDENSING UNITS LOCATED ELSEWHERE SHALL BE RATED AT 95°. 3. CONDENSING UNIT ON ROOF SHALL BE SUPPORTED ON PRE-MANUFACTURED EQUIPMENT FRAMES. REFER TO DRAWING M6-04. 4. CONDENSING UNIT INSTALLED ON PARKING DECK SHALL BE SUPPORTED ON NEOPRENE PADS. 5. PROVIDE TWO (2) SETS OF 1" FILTERS FOR UNIT. MINIMUM EFFICIENCY (500 FPM MAX. VELOCITY) MERV 8 EFFICIENCY. 6. UNIT SHALL BE WALL MOUNTED, SEE DETAIL 1/M6-02. 7. UNIT SHALL BE FLOOR MOUNTED, SEE DETAIL 4/M6-02. 8. ROUTE CONDENSATE FULL SIZE TO NEAREST FLOOR DRAIN OR HUB DRAIN. SEE PLUMBING DRAWINGS FOR EXACT LOCATIONS. 9. UNIT SHALL BE CONTROLLED BY PROGRAMABLE THERMOSTAT. 10. MANUFACTURER TO SIZE REFRIGERANT PIPING BASED ON ACTUAL PROJECT CONDITIONS; INCLUDING PIPING DIAGRAM, VALVES, AND ACCESSORIES REQUIRED FOR SYSTEM OPERATION. REFRIGERANT PIPING TO BE INSTALLED BY CONTRACTOR. 11. PROVIDE MOTOR OPERATED DAMPER INTERLOCKED WITH FCU FAN. FAN TO CYCLE BASED ON OPERATION OF THERMOSTAT. DAMPER TO CLOSE WHEN FAN CYCLES OFF. 12. PROVIDE FACTORY INSTALLED HEATER WITH SINGLE POINT CONNECTION OR DUAL CIRCUIT FOR LARGE HEATERS, REFER TO ELECTRICAL DRAWINGS. 13. PROVIDE LONG LINE KIT AND ALL MANUFACTURER'S RECOMMENDED ACCESSORIES FOR ALL REFRIGERANT LINE LENGTHS OVER THE MANUFACTURER'S STANDARD LENGTH. 14. PROVIDE 1 STAGE HEAT FOR HEATERS BELOW 5 KW. PROVIDE 2 STAGE HEAT FOR HEATERS 5 KW TO 10 KW. PROVIDE 3 STAGE HEAT FOR HEATERS OVER 10 KW. 15. PRETREATED OUTSIDE AIR SUPPLIED FROM DEDICATED OUTSIDE AIR UNIT WITH GAS HEAT. 16. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. POWER INDUCTION UNIT NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. PROVIDE PRESSURE INDEPENDENT AIR VALVE. 3. PROVIDE DIGITAL CONTROLS FOR CONNECTION TO BMS. 4. PROVIDE SINGLE POINT CONNECTION, FACTORY MOUNTED DISCONNECT FOR HEATER, AND INTEGRAL TRANSFORMER FOR CONTROL POWER. PROVIDE 1 STAGE HEAT FOR HEATERS 5 KW AND SMALLER, AND 2 STAGE HEAT FOR HEATERS ABOVE 5 KW TO 12 KW. 5. REFER TO SPECIFICATIONS FOR ADDITIONAL UNIT REQUIREMENTS. 6. PROVIDE SINGLE POINT CONNECTION, FACTORY MOUNTED DISCONNECT FOR HEATER, AND INTEGRAL TRANSFORMER FOR CONTROL POWER. PUMP NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. PROVIDE HOUSEKEEPING PAD AND INERTIA BASE UNDER PUMP. 3. PUMP SHALL BE PROVIDED WITH VARIABLE FREQUENCY DRIVE. 4. PROVIDE STARTER AND DISCONNECT. 5. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 6. NPSH = 7 FT. 7. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. EXPANSION TANK NOTES: 1. PROVIDE HOUSEKEEPING PAD. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 3. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. HOOD NOTES: 1. PROVIDE INSULATED ROOF CURB TO MATCH ROOF SLOPE. 2. PROVIDE MOTORIZED DAMPER INTERLOCKED WITH EXHAUST FAN. DAMPER SHALL OPEN WHEN FAN IS OPERATING. 3. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ELECTRIC HEATER NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR SERVICE VOLTAGE CHARACTERISTICS. 2. MAINTAIN ALL MANUFACTURER'S RECOMMENDED CLEARANCES. 3. PROVIDE BUILT-IN DISCONNECT, INTERNAL THERMOSTAT TO MAINTAIN SPACE TEMPERATURE OF 60°F ADJUSTABLE IN STAIRWELLS AND 70° ADJUSTABLE IN INTERNAL SPACES. HEATER SHALL BE MOUNTED 18" AFF. 4. PROVIDE BUILT-IN DISCONNECT, MOUNTING BRACKET (WALL/CEILING AS REQUIRED), AND UNIT MOUNTED THERMOSTAT TO MAINTAIN SPACE, ADJUSTABLE OF 70°F BELOW CONDITIONED SPACES AND 50°F ADJUSTABLE IN MECHANICAL SPACES AND OFFICE SHELL. 5. PROVIDE SURFACE MOUNTED FRAME FOR HEATER WITH DISCONNECT AND CEILING MOUNTED THERMOSTAT SET AT 60°F ADJUSTABLE. 6. PROVIDE TRENCH HEATER WITH DISCONNECT. HEATER SHALL BE PROVIDED IN MULTIPLE SECTIONS (AS NOTED) TO MAKE UP THE REQUIRED LENGTH. EACH SECTION SHALL BE INDIVIDUALLY WIRED. SECTIONS SHALL BE FLANGED TOGETHER FOR FIELD CONNECTION. EACH UNIT SHALL HAVE ITS OWN ELECTRIC ELEMENT AND ELECTRICAL BOX. PROVIDE OUTDOOR SENSOR TO ENERGIZE HEATER WHEN OUTSIDE AIR IS 50° F OR LOWER. 7. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION SCALE: 3 M6-01 T-BAR CEILING DETAIL N.T.S. MANUAL VOLUME DAMPER INSULATED FLEXIBLE DUCT MAX SAG 1/2" PER FOOT BETWEEN SUPPORTS FRAME FOR INSTALLATION IN T-BAR CEILING LINED PLENUM ADJUSTABLE GASKETED BLADE PATTERN CONTROLLERS PROVIDE FLEXIBLE ADJUSTABLE SHAFT ACCESSIBLE THROUGH FACE OF DIFFUSER IF BALANCING DAMPER IS NOT ACCESSIBLE SUSPENDED CEILING SECURELY CLAMP FLEXIBLE DUCT TO DIFFUSER FITTING BETWEEN WIRES OF THE LAST SPIRAL WITH 1/2" STAINLESS STEEL ADJUSTABLE BAND CLAMP WITH CADMIUM PLATED BUCKLE AND SLOTTED HEX-HEAD SCREW SCALE: 2 M6-01 TYPICAL SLOT DIFFUSER GYPSUM CEILING DETAIL N.T.S. SUSPENDED CEILING, SEE ARCHITECTURALRADIUS OF BEND ATLEAST1 1/2 X DIAMETER OFFLEX DUCTSCALE: 1 M6-01 N.T.S. FLEXIBLE DUCTWORK IN ACCESSIBLE CEILING ONLY FLEXIBLE DUCT CLAMP PER SPECIFICATION SECTION 233330 CEILING TEE CEILING TEE NOTES: 1. INSTALL DAMPERS PER CODE AND MANUFACTURER'S REQUIREMENTS FOR UL INSTALLATION. 2. SEAL BREAK-AWAY CONNECTIONS. 3. TAPE INSULATION TO DUCT AT BREAK-AWAY CONNECTIONS. 4. BREAK-AWAY CONNECTIONS AND RETAINING ANGLES SHALL BE VISIBLE. SCALE: 5 M6-01 TYPICAL FIRE DAMPER MOUNTING DETAIL N.T.S. FUSIBLE LINK 1-1/2x1" 1/2x1/8" GALV. SLEEVE RETAINING ANGLE MINIMUM 1" OVERLAP ON WALL. SLEEVE ACCESSIBLE ACCESS PANEL TYPE B FIRE DAMPER. REFER TO PLAN AND SCHEDULES FOR RATING. 6" MAX FIRE RATED WALL CONSTRUCTION PER ARCHITECTURAL DOCUMENTS 6" MAX ACCESSIBLE LOCATION OR ACCESS PANEL 1/2" GAP, 4 SIDES CEILING SCHEDULED NECK SIZE TYPICAL SLOT DIFFUSER LINED PLENUM CEILING FRAMING INSULATION FLEXIBLE DUCT IN ACCESSIBLE CEILINGS, SHEET METAL DUCT FOR INACCESSIBLE CEILINGS SECURELY CLAMP FLEXIBLE DUCT TO DIFFUSER FITTING BETWEEN WIRES OF THE LAST SPIRAL WITH 1/2" STAINLESS STEEL ADJUSTABLE BAND CLAMP WITH CADMIUM PLATED BUCKLE AND SLOTTED HEX-HEAD SCREW. MAXIMUM SAG 1/2" PER FOOT BETWEEN SUPPORTS FOR FLEXIBLE DUCTWORK CONCEALED DAMPER ADJUSTMENT SCREW REFER TO SCHEDULES FOR DIFFUSER TYPE AND DIMENSIONS GYPSUM BOARD CEILING NOTES: 1. INSTALL DAMPERS PER CODE AND MANUFACTURER'S REQUIREMENTS FOR UL INSTALLATION. 2. WHEN MULTIPLE DAMPERED ASSEMBLIES ARE JOINED OR FASTENED TO THE SLEEVE, DAMPER SHALL BE FASTENED WITH NO. 10 SCREWS SPACED 6" MAXIMUM, CENTER TO CENTER. 3. PROVIDE DUCT ACCESS PANEL ON MOTOR SIDE OF DAMPER. 4. PROVIDE SMOKE DETECTORS PER MECHANICAL CODE. SCALE: 4 M6-01 TYPICAL COMBINATION FIRE AND SMOKE DAMPER DETAIL N.T.S. DUCT LINER INSULATION OVERLAP DUCT LINER 2" SLEEVE INSULATED HINGED ACCESS PANEL IN DUCT 1-1/2X1" 1/2X1/8" GALV. SLEEVE RETAINING ANGLE MINIMUM 1" OVERLAP ON WALL. 1/2" GAP, 4 SIDES FIRE RATED WALL CONSTRUCTION PER ARCHITECTURAL DOCUMENTS 6" MAX ACCESSIBLE LOCATION OR ACCESS PANEL IN CEILING 6" MAX M CEILING SCALE: 7 M6-01 COMBINATION FIRE AND SMOKE DAMPER WITH GRILLE MOUNTING DETAIL N.T.S. NOTES: 1. INSTALL DAMPERS PER MANUFACTURER'S REQUIREMENTS FOR UL INSTALLATION. 2. SEAL BREAK-AWAY CONNECTIONS. 3. TAPE INSULATION TO DUCT AT BREAK-AWAY CONNECTIONS. 4. BREAK-AWAY CONNECTIONS AND RETAINING ANGLES SHALL BE VISIBLE. 5. OPERATOR/ACTUATOR DAMPER MAY BE SUPPLIED WITHOUT OPERATOR/ACTUATOR INSTALLED. UL LISTED FIRE DAMPER OPERATORS SPECIFIED ON DAMPER MARKING MAY BE FIELD INSTALLED. SEE OPERATOR/ACTUATOR INSTALLATION INSTRUCTIONS FOR FIELD MOUNTING OF DAMPER OPERATORS. NOTE 5 FIRE/SMOKE RATED WALLCONSTRUCTION PERARCHITECTURAL PLAN #8 MIN. FASTENER CAULKING MATERIAL GRILLE SLEEVE TRANSFER DUCT SIZE, SEE PLANS CEILING AIR FLOW AIR FLOW ACOUSTICAL DUCT LINING ACOUSTICAL SEALANT TYPICAL WALL CONSTRUCTION PER ARCHITECTURAL PLANS TRANSFER DUCT SIZE, SEE PLANS AIR FLOW CEILING AIR FLOW CEILING TRANSFER GRILLE SIZE AND TYPE AS NOTED ON PLANS ACOUSTICAL DUCT LINING WALL CONSTRUCTION PER ARCHITECTURAL PLANS SCALE: 8 M6-01 TRANSFER AIR DUCT WITH GRILLES DETAIL N.T.S. AIR FLOW TRANSFER DUCT SIZE PER PLANS CEILING AIR FLOW CEILING ACOUSTICAL DUCT LINING ACOUSTICAL SEALANT TYPICAL WALL CONSTRUCTION PER ARCHITECTURAL PLANS TRANSFER GRILLE SIZE AND TYPE AS NOTED ON PLANS TYPICAL SUPPLY DIFFUSER CONNECTION DETAIL FOR SUSPENDED CEILING NOTES : 1. REFER TO SCHEDULES FOR SLOT DIFFUSER DIMENSIONS. 2. WHERE SPIN-IN DUCT CONNECTION IS ABOVE AN ACCESSIBLE CEILING, OMIT DAMPER AT DIFFUSER AND PROVIDE BALANCING DAMPER AT SPIN-IN.NOTES : 1. REFER TO SCHEDULES FOR SLOT DIFFUSER DIMENSIONS. 2. SLOT RETURN REGISTERS ARE SIMILAR INSTALLATION WITH RETURN PLENUM OR LIGHT SHIELD AS NOTED. NOTES : 1. REFER TO CONTRACT DOCUMENTS FOR DIFFUSER SCHEDULE AND DUCTWORK SIZES. NOTES: SCALE: 6 M6-01 TYPICAL SMOKE DAMPER MOUNTING DETAIL N.T.S. SLEEVE 1. INSTALL DAMPERS PER CODE AND MANUFACTURER'S REQUIREMENTS FOR UL INSTALLATION. 2. SEAL BREAK-AWAY CONNECTIONS. 3. TAPE INSULATION TO DUCT AT BREAK-AWAY CONNECTIONS. 4. BREAK-AWAY CONNECTIONS AND RETAINING ANGLES SHALL BE VISIBLE. 5. OPERATOR/ACTUATOR DAMPER MAY BE SUPPLIED WITHOUT OPERATOR/ACTUATOR INSTALLED. UL LISTED SMOKE DAMPER OPERATORS SPECIFIED ON DAMPER MARKING MAY BE FIELD INSTALLED. SEE OPERATOR/ACTUATOR INSTALLATION INSTRUCTIONS FOR FIELD MOUNTING OF DAMPER OPERATORS. NOTE 5 NOTES 2, 3 & 4 SMOKE RATED WALL CONSTRUCTION PER ARCHITECTURAL PLAN 1-1/2x1" 1/2x1/8" GALV. SLEEVE RETAINING ANGLE MINIMUM 1" OVERLAP ON WALL. ACCESSIBLE LOCATION OR ACCESS PANEL 24" MAX 24" MAX M CEILING c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:22:45 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM6−01 08.14.18MECHANICAL DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION ROOF SLAB SCALE: ROOF SLAB NOTES: 1. REFER TO ARCHITECTURAL DETAILS FOR ADDITIONAL INFORMATION. ROOF PENETRATION REFRIGERANT PIPING DETAIL2 N.T.S. SPRAY WEATHER PROOF FOAM IN HOUSING AFTER ROOFING AND PIPING IS COMPLETE. MINERAL WOOL STARTING 2" BELOW TOP OF ROOF INSULATION. 1" WATERPROOFING INSULATION. SEE SPECIFICATIONS FOR THICKNESS AND SIZE. SHEETMETAL HOUSING ROOFING CONTRACTOR TO FLASH/WEATHER PROOF HOUSING TO ROOF REFRIGERANT PIPING EXITING BOTH SIDES OF HOUSING. MINIMUM 22 GAGE METAL ENCLOSURE. CEILING FCU COOLING COIL CEILING 1. DUCTWORK SHOWN FOR SCHEMATIC ONLY. 2. AUXILIARY CONDENSATE SHALL BE INTERNAL SECONDARY DRAIN PAN WITH FLOAT SWITCH. UNIT SHALL SHUT DOWN UPON ACTIVATION OF FLOAT SWITCH. 3. WATER IS INSTALLED BELOW UNIT. FAN COIL UNIT SHALL BE INSTALLED ABOVE WATER HEATER. NOTES: SCALE: RETURN AIR 1 M6-02 N.T.S. TYPICAL APARTMENT FAN COIL UNIT MOUNTING DETAIL - SIDE VIEW FILTER INTERNAL SECONDARY DRAIN PAN WITH FLOAT SWITCH CONDENSATE ROUTED AS SHOWN ON PLUMBING DRAWINGS SEE DETAIL 8/P7.1 WALL SUPPLY AIR DUCT SIZE AS NOTED ON PLAN WALL REFRIGERANT LINES TO CONDENSING UNIT WATER HEATER ON FLOOR FLOOR RETURN AIR GRILLEWALL BRACKET FOR UNIT PVC CONDENSATE DRAIN LINE, FULL SIZE OF UNIT OPENING, ROUTE TO SPLASH BLOCK. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION. OUTSIDE AIR UNIT ROOF OUTSIDE AIR INTAKE NOTES: 1. DETAIL IS SCHEMATIC ONLY, REFER TO DRAWING FOR LAYOUT. 2. OUTSIDE AIR DUCTWORK SHALL BE INSULATED AND PROVIDED WITH WEATHER JACKET AS NOTED IN SPECIFICATIONS 3. CONDENSATE DRAIN LINE SHALL BE FULL SIZE OF UNIT OPENING AND ROUTED TO NEAREST ROOF DRAIN. SEE PLUMBING DRAWINGS FOR LOCATION. 4. SEE DRAWINGS FOR SIZE AND ROUTING OF DUCTWORK. SCALE: OUTSIDE AIR ROOFTOP UNIT HORIZONTAL DISCHARGE DETAIL N.T.S. 3 ROOF CURB OR SUPPORT CEILING FCU COOLING COIL CEILING 1. DUCTWORK SHOWN FOR SCHEMATIC ONLY, SEE DRAWINGS FOR EXACT LOCATION AND SIZE OF DUCTWORK. 2. DAMPER MOTOR OPERATOR SHALL BE THE SAME VOLTAGE AS THERMOSTAT AND CONTROLLED BY THERMOSTAT. POWER SOURCE SHALL BE SIZED AT 125% OF CONNECTED LOAD. MOTOR OPERATED DAMPER SHALL OPEN WITH FAN ON AND CLOSE WITH FAN OFF. 3. AUXILIARY CONDENSATE SHALL BE ROUTED TO DRAIN PAN WITH FLOAT SWITCH. UNIT SHALL SHUT DOWN UPON ACTIVATION OF SWITCH. NOTES: SCALE: RETURN AIR WITH BALANCING DAMPER FILTER RACK CONDENSATE ROUTED AS SHOWN ON PLUMBING DRAWINGS, SEE DETAIL X/PX-XX. N.T.S. 4 FAN COIL UNIT PUBLIC SPACE VERTICAL MAOUNTING DETAIL DRAIN PAN WITH FLOAT SWITCH SUPPLY AIR DUCT SIZE AS NOTED ON PLAN REFRIGERANT LINES TO CONDENSING UNIT MOTOR OPERATED DAMPER PLENUM W/ 1" LINER OUTSIDE AIR DUCTWORK WALLFLEXIBLE CONNECTION FULLY LOUVERED DOOR NEOPRENE ISOLATION PADS (TYP.)SLAB SCALE: 5 DUCTLESS SPLIT CONDENSING UNIT DETAIL N.T.S. REFRIGERANT LINES PITCH POCKET ROOF PENETRATION; SEE 2/M6-01 MINIMUM VENDOR RECOMMENDED CLEARANCE ALL SIDES AND BETWEEN ADJACENT UNITS SLIP SHEET PRESSURE TREATED TIMBERS SCALE: REFRIGERANT PIPING UP IN WALL CONDENSATE PUMP IN METAL PAN BETWEEN STUDS IF NOTED ON SCHEDULE CONDENSATE TO DRAIN IF PUMP IS NOT REQUIRED 8X8 ACCESS PANEL IF CONDENSATE PUMP IS REQUIRED DUCTLESS FAN COIL UNIT MOUNT PER MFR'S RECOMMENDATIONS CEILING CLEARANCE PER MFR'S RECOMMENDATIONS TO CONDENSING UNIT FIRESTOP PER SPECIFICATIONS PUMP DISCHARGE TO DRAIN 7 DUCTLESS SPLIT SYSTEM WALL MOUNTING DETAIL N.T.S. WALL ROLLER TYPE CLEVIS HANGER WITHIN 36" OF WALL HIGH TEMPERATURE INSULATION PER SPECIFICATIONS SCHEDULE 40 STEEL EXHAUST PIPE 24" MIN. STEEL WALL SLEEVE MIN. 1/4" CLEAR ALL AROUND CUT 45° GAP BETWEEN INSULATION AND WEATHER SHIELD: LENGTH OF EXHAUST PIPE (FT) X 0.1 = GAP (IN INCHES) ATTACH TO WALL 6" OC (MIN 5) 2" MINIMUM OUTSIDE OF WALL SLEEVE 2" LONG SEMI-CIRCLE HOOD OVER PIPE. WELD HOOD TO WALL PLATE. EXHAUST PIPE CAULK PLATE TO WALL EXPANSION FACTORS: 0.1/FT FOR NATURAL GAS 0.06/FT FOR DIESEL 0.08/FT FOR GASOLINE SCALE: 8 GENERATOR EXHAUST PIPE THROUGH WALL DETAIL N.T.S. ABOVE FINISHED FLOOR 3" TURN FLOOR REINFORCING 6" MINIMUM UNLESS SPECIFIED OTHERWISE. 16 GAUGE STEEL TIE WIRE CONCRETE BASE, 3000 PSI. OF 2" OF COVER. EACH DIRECTION WITH A MINIMUM 3/8" REINFORCING RODS, 6" O.C. FINISHED FLOOR NOTES: 1. CONCRETE BASE SHALL BE 6" LARGER ALL AROUND THAN THE BASE OF THE EQUIPMENT BEING SUPPORTED. ROUGHEN AND MOISTEN FLOOR BEFORE POURING 1" CHAMFER ALL AROUND C C FAN NOTES: 1. CONDENSATE DRAIN SHALL BE ROUTED AND PIPED AS NOTED ON PLUMBING DRAWINGS. 2. COILS SHALL BE PIPED FROM OVERHEAD. PROVIDE 2-WAY VALVES TO OPEN ON DEMAND FOR COMPRESSOR OPERATION. COOLING COIL RETURN AIR FLOOR ANGLE FILTERS OUTSIDE AIR FROM DOAS UNIT. SCALE: SUPPLY AIR DUCT ISOLATION VALVE MOTOR OPERATED VALVETO CONDENSER/COMPRESSOR ASSEMBLY. SEE X/MX-XX VFD AND DISCONNECT MOUNTED ON UNIT OR WALL VIBRATION ISOLATOR PADS. SEE SPECIFICATIONS-TYPICAL PIPE SUPPORT, SEE DETAIL 8/M6-03 (TYP.) 9 SELF CONTAINED UNIT DETAIL N.T.S. CWR HEADER CWRSTRUCTURAL STEEL SEE STRUCTURAL DRAWING.ROOF COOLING TOWER CWS FROM TOWER THRU BUILDING WALL. PROVIDE PIPE SUPPORT, SEE DETAIL 10/M6-03. CWR TO TOWER THRU BUILDING WALL. PROVIDE PIPE SUPPORT, SEE DETAIL 10/M6-03. 1" DEFLECTION HOUSED SPRING ISOLATOR (MINIMUM 4) 3'-0" MINIMUM NOTES: ALL PIPING SHALL BE INSULATED, HEAT TRACED, AND WEATHERPROOFED WITH PROTECTED WEATHER JACKET, SEE SPECIFICATIONS. ALL PIPING SHALL BE SUPPORTED INDEPENDENT OF COOLING TOWER. PROVIDE ROOF MOUNTED EQUIPMENT SUPPORTS FOR PIPING. SEE DETAIL X/MXXX. SCALE: 11 N.T.S. COOLING TOWER DETAIL STEEL BEAM FRAME PER MANUFACTURER'S INSTALLATION DETAILS. FLEXIBLE PIPE CONNECTION CWR 2-POSITION AUTO ISOLATION VALVE BUTTERFLY VALVE MAKEUP WATER PLUGGED WATER LEVEL PROBE OVERFLOW DRAIN FLEXIBLE PIPE CONNECTION DRAIN WITH BALL VALVE BUTTERFLY VALVE DRAIN, SEE PLUMBING DRAWINGS FOR CONTINUATION (TYP.) CWR P AIR FLOW P P CONDENSER WATER OUT COMBINATION BALANCING AND SHUT-OFF VALVE REDUCING ELBOWS (WHERE REQUIRED) AIR FLOW CONDENSER WATER DX COIL CONDENSATE DRAIN AND TRAP, SEE PLUMBING DRAWINGS REDUCING ELBOWS (WHERE REQUIRED) UNION 3/4" HOSE END DRAIN VALVE COMBINATION PRESSURE/ TEMPERATURE TEST PLUG TYPICAL VENT CONNECTION PROVIDED BY COIL MANUFACTURER MANUAL AIR VENT GATE VALVE CONDENSER WATER IN CONDENSER DX COOLING COIL SCALE: 10 CONCRETE BASE DETAIL N.T.S. FLOOR MOUNTED EQUIPMENT SCALE: 12 PIPING DETAIL (2-WAY) N.T.S. SELF CONTAINED UNIT SCALE: 13 NONE END SUCTION PUMP PENTHOUSE SIDE VIEWSECTION A-A DISCHARGE ANCHOR BOLTS & EXPANSION ANCHORS. INSTALL AS RECOMMENDED BY PUMP MANUFACTURER. FLEXIBLE CONNECTION INLET CONCRETE PAD. SEE EQUIPMENT CONCRETE BASE DETAIL SPRING ISOLATORS & INERTIA BASE FLEXIBLE CONNECTION TEMPERATURE/PRESSURE TEST PORT CONCENTRIC REDUCER COUPLING GUARD FLEXIBLE CONNECTION CONCENTRIC REDUCER END SUCTION DIFFUSER WITH STRAINER INERTIA BASE, SIZED PER PUMP MANUFACTURER'S RECOMMENDATIONS. PRESSURE GAUGE STOP COCK A A BUTTERFLY VALVE BUTTERFLY VALVE BUTTERFLY VALVE LIFT CHECK VALVE LIFT CHECK VALVE SCALE: 6 FLAT ROOF MOUNTED CENTRIFUGAL EXHAUST FAN DETAIL N.T.S. SPUN ALUMINUM DISCHARGE APRON EQUIPPED WITH: VIBRATION ELIMINATOR, BIRD SCREEN AND NON-FUSED DISCONNECT SWITCH ALUMINUM CURB CAP ROOF CURB DAMPER AS SCHEDULED EXHAUST DUCT SIZE PER PLAN ROOF STRUCTURE-SEE ARCH. AND STRUCTURAL PLANS AND DETAILS FOR CONSTRUCTION. SCALE: AIR FLOW THREADED EXPANSION ANCHOR DUCT BOTTOM ACCESS PANELDIRECT DRIVE FAN MOTOR FLEXIBLE CONNECTION (TYP) MOUNTING BRACKET BY FAN MANUFACTURER (TYP) STEEL HEX NUT & FLAT WASHER VIBRATION ISOLATOR STEEL HEX NUT & FLAT WASHER GALVANIZED STEEL THREADED ROD CONCRETE SLAB 14 IN-LINE FAN - SUSPENDED N.T.S. M6-02M6-02M6-02M6-02M6-02 M6-02M6-02M6-02 M6-02 M6-02M6-02M6-02M6-02 NOTES: 1. GAUGE PIPING 1/4" GAU. STEEL PIPE & FITTINGS SCHEDULE 40. 2. BYPASS STOP COCK, 150 PSI OPERATING PRESSURE, MIN. 3. PIPE TO PUMP FLANGE CONNECTION POINTS. 4. REFER TO PLANS & SPECIFICATIONS FOR SIZES & LOCATIONS. 5. DOUBLE SUCTION SPLIT CASE PUMP DETAIL SIMILAR; SIDE INLET. 6. NO SUCTION DIFFUSER ON DOUBLE SUCTION SPLIT CASE PUMPS; 7. OPTION: PROVIDE TRIPLE DUTY VALVE IN PLACE OF CHECK AND STRAINER PROVIDED IN LINE PRIOR TO PUMP INLET. BUTTERFLY VALVE ON OUTLET OF PUMP. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:23:06 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM6−02 08.14.18MECHANICAL DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION UNION GATE VALVE AIR VENT REFER TO NOTE 2 3/4"X6" LONG NIPPLE DIRCTION OF FLOW HIGH POINT OF PIPING SYSTEM DRAIN LINE REFER TO PLANS AND SPECIFICATIONS. REFER TO NOTE 1 TO FLOOR DRAINAUTO AIR VENT UNION GATE VALVE GATE VALVE UNION ROUTE TO FLOOR DRAIN BLACK STEEL SUPPORT POST - 4 PLACES ℄ ANCHOR BOLT FLAT AND LOCK WASHER EXPANSION ANCHOR EXISTING CONC. FLOOR CONTINUOUS WELDED GUSSET PLATE LINE SIZE OUTLET CONNECTION NOTES: 1. REFER TO PLUMBING DRAWINGS FOR SIZE AND LOCATION FLOOR LINE SIZE INLET CONNECTION AIR SEPARATOR BASE RING BY MANUFACTURER COLD WATER LINE INLET. REFER TO PLUMBING DRAWINGS FOR SIZE AND LOCATION CONTINUOUS WELD (TYP) ANCHOR BOLTSCONCRETE PAD 3/4" GATE VALVE WITH HOSE CONNECTOR DIRECTION OF FLOW DIRECTION OF FLOW CHEMICAL BYPASS FEEDER SCREW ON CAP FINISHED FLOOR UNION UNION 3/4" MIN AIR VENT PRESSURE GAUGE GAUGE COCK 3/4" DRAIN WITH DRAIN VALVE 6" CONCRETE PAD EXPANSION TANK CHARGING VALVE ENCLOSURE TO SYSTEM PUMP STEEL PLATE - 6" LARGER THAN BASE RING DIAMETER STEEL BASE PLATE WELDED TO POST. ANCHOR BOLTS TO FLOOR WITH STEEL HEX BOLTS W/ FLAT AND LOCK WASHERS AND EXPANSION ANCHOR. EQUIPMENT PAD HEAT EXCHANGER HX-1 OFFICE CONDENSER WATER PIPING BETWEEN HEAT EXCHANGER AND SCU'S PRESSURE GAUGE & TEST COCK THERMOMETER & TEST WELL STOP VALVE WATER PIPING BETWEEN COOLING TOWER AND HEAT EXCHANGER P-1 P-2 1/8" TUBING TO FLOOR DRAIN EXPANSION TANK SEE SPECIFICATIONS P-4 P-5 CWR CWS STRAINER INSULATION STRUCTURAL STEEL REFER TO STRUCTURAL DRAWINGS SCHEDULE SUPPORTED PIPE SIZE 4" 6" 8" 10" 12" OVER 12" PIPE SUPPORT SIZE 1-1/2" 2" 2" 3" 3" 4" ℄ ℄ RISER EXPANSION SHIELD 4 EA. HEX ANCHOR BOLT 3/8"X3" 4 EA. FLOOR FLAT & LOCK WASHER 1/4" STEEL PLATE SLIP-ON FLANGE & BOLT SET CONTINUOUS WELD SCH 40 BLACK STEEL SUPPORT PIPE; SEE SCHEDULE SUPPORT FROM STRUCTURE HANGER ROD LOCK WASHER (TYP) 180° INSULATION SHIELD *NOTE 1 16 GA GALVANIZED 12" MIN. LENGTH INSERT, 12" LENGTH INSULATION CLEVIS TYPE HANGER PIPE 1. 180° INSULATION SHIELDS WITH SS BANDS. 2 PER SHIELD. 2. PIPE HANGERS, SUPPORTS AND RODS SHALL HAVE A FACTORY GALVANIZED FINISH. 3. PROVIDE SPRING ISOLATORS ON ALL PIPING. INSULATION NUT & LOCK WASHER TOP & BOTTOM, (TYP) TO STRUCTURE (TYP ALL HANGERS) GALVANIZED U-BOLT OR CLAMP.(2) 180°, 16 GA GALVANIZED INSULATION SHIELDS, 12" MIN LENGTH, SEE NOTE 1 3 X 3 X 1-1/4" GALVANIZED ANGLE IRON SPRING ISOLATOR SPRING ISOLATOR (TYP.) NOTES: SEE NOTE 3 4"℄ SCH 40 PIPE COLUMN 3/8"x9"x9" BASE PLATE w/FOUR 1/2"℄ BOLTS PRIMARY AIR FLOW RECIRCULATION AIR FLOW SCALE: 1 M6-03 PARALLEL FAN POWERED BOX ELECTRIC HEATING COIL DETAIL N.T.S. NOTE: PROVIDE UNIT WITH BOTTOM ACCESS DOOR(S) AIR VALVE/DAMPER. WHEN SIDE CLEARANCE IS NOT AVAILABLE CONTROL BOX PROVIDE ACCESS AIR VALVE/DAMPER FILTER AS SPECIFIED MOUNTED ON FILTER FRAME PARALLEL FAN-POWERED VAV BOX (PIU) ELECTRIC HEATING COIL FLEXIBLE CONNECTION SUPPLY AIR DUCT SIZE PER PLAN ISOLATORS PER SPECIFICATION SECTION 230548. FAN AND MOTOR MINIMUM LENGTH OF STRAIGHT RIGID DUCT BETWEEN VAV BOX INLET AND FIRST UPSTREAM ELBOW OR REDUCER NOT LESS THAN 6 DUCT DIAMETERS. SUPPORT WITH CHANNEL OR UNISTRUT AS RECOMMENDED BY UNIT MANUFACTURER SCALE: SUPPLY AIR 2 SERIES FAN POWERED BOX ELECTRIC HEATING COIL DETAIL N.T.S. NOTE: PROVIDE UNIT WITH BOTTOM ACCESS DOOR(S) AIR VALVE/DAMPER. WHEN SIDE CLEARANCE IS NOT AVAILABLE CONTROL BOX PROVIDE ACCESS ELECTRIC HEATING COIL SERIES FAN-POWERED VAV UNIT FLEXIBLE CONNECTION FAN & MOTOR MINIMUM LENGTH OF STRAIGHT RIGID DUCT BETWEEN VAV BOX INLET AND FIRST UPSTREAM ELBOW OR REDUCER NOT LESS THAN 6 DUCT DIAMETERS. AIR VALVE FILTER AS SPECIFIED MOUNTED ON FILTER FRAME RECIRCULATION DUCT AND FLEXIBLE CONNECTOR IF SHOWN ON PLAN PRIMARY AIR FLOW M6-03 3 M6-03 TYPICAL FLOOR MOUNTED AIR SEPARATOR DETAIL NONESCALE: NOTES: 1. STEEL CHEMICAL BYPASS FEEDER. PART NO. FB5-QC-AR CANNON WATER TECHNOLOGY, INC OR APPROVED EQUAL. MINIMUM, WORKING PRESSURE 150 PSI. NOTES: 1. PIPE DOWN LINE TO NEAREST FLOOR DRAIN. 2. EXPANSION TANK EQUIPPED WITH REPLACEABLE BLADDER. NOTES: 1. PIPE DRAIN TO NEAREST FLOOR DRAIN IN MECHANICAL ROOMS; TURN DOWN OVER JANITORS MOP SINK; TO "P" TRAP, OR TO EXTERIOR. 2. AUTOMATIC AIR VENT AT THE HIGH POINTS OF THE PIPING SYSTEM; OTHER LOCATIONS WHERE SHOWN OR WHERE CHANGE IN DIRECTION REQUIRES VENTING. P-3 TO OFFICE CWSFROM OFFICE CWR P-6 SCALE: 8 M6-03 SUSPENDED PIPE SUPPORT DETAIL NONE SCALE: 7 M6-03 VERTICAL PIPE FLOOR SUPPORT DETAIL NONE SCALE: 6 M6-03 TYPICAL BYPASS FEEDER DETAIL NONE SCALE: 5 M6-03 FLOOR MOUNTED EXPANSION TANK NONE SCALE: 4 M6-03 TYPICAL AUTOMATIC AIR VENT DETAIL NONE SCALE: 9 M6-03 TYPOCAL HEAT EXCHANGER PIPING DIAGRAM NONESCALE: 10 M6-03 TYPICAL COOLING TOWER PIPE SUPPORT DETAIL NONE c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:23:27 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM6−03 08.14.18MECHANICAL DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION SCALE: 2 M6-04 RACK ISOMETRIC DETAIL N.T.S. CONDENSING UNIT 3"x3"x1/4" ANGLE 3"x3"x1/4" ANGLE 3"x3"x1/4" ANGLE WELD FOUR CORNERS SCALE: 1 M6-04 RACK DETAIL N.T.S. CONDENSING UNIT 2'-6" 11'-6"3"2'-6" 3"x3"x1/4" ANGLE MINIMUM 24" FROM FINISHED ROOF TO BOTTOM OF FRAME SCALE: 5 M6-04 FRAME ELEVATION DETAIL N.T.S. CONDENSING UNIT SCALE: 4 M6-04 RACK & FRAME DETAIL N.T.S. CONDENSING UNIT RACK SITS INSIDE FRAME SCALE: 3 M6-04 FRAME ISOMETRIC DETAIL N.T.S. CONDENSING UNIT WELD FOUR CORNERS OUTSIDE FRAME FOUR 4"x4"x5/8" ANGLE WELD 6 (SIX) 3"Ø POSTS TO FRAME FRAME WITH 3" Ø POSTS SET ON 6 (SIX) 2-1/2"Ø POSTS EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL SCALE: 7 M6-04 MOUNTING DETAIL N.T.S. CONDENSING UNIT 20'-6"11'-7 1/2"SCALE: 6 M6-04 FRAME DETAIL N.T.S. CONDENSING UNIT c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/10/2018 4:23:47 PM C:\Users\Dejong.LEPPARDJOHNSON\Documents\17062 - Mechanical_v17_Dejong.rvtM6−04 08.14.18MECHANICAL DETAILS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUED FOR CONSTRUCTION 3 3 4 O O GEN ELEV O FAAP FACP F S S H S SA S CO F R SACO GRAPHICAL STANDARDS DRAWING NUMBER SHEET NUMBER DRAWING SCALE DRAWING NUMBER SHEET NUMBER AREA TO BE ENLARGED }ENLARGED AREA DRAWING PLAN NORTH TRUE OR MAGNETIC NORTH INDICATES GENERAL REGION WITH REVISIONS REVISION NUMBER DRAWING NUMBER SHEET NUMBER } SECTION DRAWING DRAWING CALLOUT ENLARGED CALLOUT SECTION CALLOUT PLAN & TRUE NORTH REVISION CLOUD REVISION TRIANGLE SCALE: 1 X1 1 X1 1 X1 DRAWING TITLE 1/8" = 1'-0" 1 NOTES: L1. CAPITAL LETTERS ADJACENT FIXTURES DESIGNATES FIXTURE TYPE IN LIGHT FIXTURE SCHEDULE. LOWER CASE LETTER DESIGNATES DIMMING ZONE OR SWITCH LEG. L2. SHADED CIRCLE IS TYPICAL INDICATOR FOR EGRESS LIGHTING. FLUORESCENT STRIP SYMBOL(S) DESCRIPTION NOTES MOUNT HEIGHT PENDANT FIXTURE EXHAUST FAN WITH LIGHT EXHAUST FAN POLE AND FIXTURE RECESSED FIXTURE BOLLARD FIXTURE FLOOD LIGHT EGRESS FIXTURE WALL EXIT LIGHT CEILING EXIT FIXTURE DIRECTIONAL FIXTURE WALL OR SCONCE FIXTURE FLUORESCENT OVERHEAD FIXTURE FLUORESCENT WALL FIXTURE FLUORESCENT STRIP WITH EMERGENCY BACKUP SURFACE FIXTURE RECESSED FIXTURE W/ EMERGENCY BACKUP PADDLE FAN (SHOWN WITH LIGHTS)LIGHT STEP OR RECESSED WALL FIXTURE W/ EMERGENCY BACK UP FLUORESCENT TROFFER W/ EMERGENCY BACKUP EXTERIOR WALL PACK FIXTURE FLUORESCENT TROFFER FLUORESCENT OVERHEAD EMERGENCY FIXTURE EXIT SIGN W/ EGRESS LIGHT HEADS EGRESS LIGHT HEADS STEP OR RECESSED WALL FIXTURE FLUORESCENT WALL FIXTURE W/ EMERGENCY BACKUP WALL OR SCONCE FIXTURE W/ EMERGENCY BACKUP SINGLE HEAD FLOOD LIGHT ABBREVIATIONS ABBREVIATIONS ARE FOR REFERENCE ONLY AND MAY OR MAY NOT BE USED ELSEWHERE IN CONSTRUCTION DOCUMENTS. A AMPERE AC ALTERNATING CURRENT AF ARC-FAULT PROTECTION (ARC-FAULT CIRCUIT INTERRUPTER) AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMP INTERRUPTING CURRENT AL ALUMINUM AWG AMERICAN WIRE GAUGE BKR BREAKER BLDG BUILDING BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CATV COMMUNITY ACCESS TELEVISION CL CENTERLINE CKT CIRCUIT CLG CEILING CU COPPER DDC DIRECT DIGITAL CONTROL D DEDICATED DT DATA/TELEPHONE CONDUIT DWG DRAWING E OR EM EMERGENCY EA EACH ELEC ELECTRICAL ELEV ELEVATOR EMT ELECTRICAL METALLIC TUBING ENT ELECTRICAL NONMETALLIC TUBING EXH EXHAUST EX EXISTING FACP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPS FLUOR FLUORESCENT GF OR GFI GROUND FAULT PROTECTION (GROUND FAULT CIRCUIT INTERRUPTER) G OR GND GROUND HP HORSEPOWER HVAC HEATING, VENTILATING, AIR CONDITIONING HZ HERTZ IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT J OR JB JUNCTION BOX KVA KILOVOLT-AMPERES LFNC LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT LV LOW VOLTAGE LTG LIGHTING LRA LOCK ROTOR AMPS MATV MASTER ANTENNA TELEVISION MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUGS ONLY N NEUTRAL NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE OCP OVERCURRENT PROTECTION PNL PANELBOARD OR PANEL POS POINT OF SALE R RELOCATED REC RECESSED RECEPT RECEPTACLE RMC RIGID METAL CONDUIT RM ROOM RNC RIGID NONMETALLIC CONDUIT SQFT SQUARE FOOT STD STANDARD SUSP CLG SUSPENDED CEILING SW SWITCH TYP TYPICAL UG UNDERGROUND V VOLTS VA VOLT-AMPERE W WATTS WP WEATHERPROOF XFMR TRANSFORMER TELE TELEPHONE TEMP TEMPERATURE TV TELEVISION UPS UNINTERRUPTED POWER SUPPLY SYMBOLS LISTED BELOW ARE FOR REFERENCE AND FOR THE USE IN UNDERSTANDING THE DESIGN INTENT. NOT ALL SYMBOLS LISTED BELOW ARE NECESSARILY USED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. SURFACE MOUNTED PANELBOARD FLUSH MOUNTED PANELBOARD FUSED DISCONNECT - XX DESIGNATES AMP RATING AND YY FUSE SIZE. * FUSE PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. XX/YY NON-FUSED DISCONNECT - XX DESIGNATES AMP RATINGXX SYMBOL(S)MOUNTING HEIGHT SINGLE RECEPTACLES (WALL/FLOOR/CEILING)E3 OR 18" AFF DUPLEX RECEPTACLES (WALL/FLOOR/CEILING)E3 OR 18" AFF QUAD RECEPTACLES (WALL/FLOOR/CEILING)E3 OR 18" AFF SPECIAL HEIGHT RECEPTACLES (WALL/FLOOR/CEILING) HALF SWITCHED DUPLEX (WALL/FLOOR)E3 OR 18" AFF GROUND FAULT DUPLEX RECEPTACLE E3 OR 18" AFF J J JUNCTION BOX (WALL/FLOOR/CEILING)J PP POWER POLE CLOCK RECEPTACLEC CIRCUITING INSTALLED EXPOSED SWITCH - TOGGLE/DIMMER/KEYED TOGGLE E3 OR 42" AFF THREE-WAY SWITCH - TOGGLE/DIMMER/KEYED3 E3 OR 42" AFF FOUR-WAY SWITCH E3 OR 42" AFF WALL MOUNTED OCCUPANCY SENSOR WITH INTEGRAL SWITCH E3 OR 42" AFF CEILING MOUNTED OCCUPANCY SENSOR - CLOSED CIRCLE INDICATES SWITCH LEG REMOTE GENERATOR CONTROL PANEL ELEVATOR CONTROL PANEL NOTES E2 E2 E2 E2 E2 GROUND WALL MOUNTED OCCUPANCY SENSOR - CLOSED CIRCLE INDICATES SWITCH LEG NOTES: E1. CIRCUIT NUMBERS SEPARATED BY COMMAS INDICATE MULTIWIRE BRANCH CIRCUIT IN COMMON RACEWAY. CIRCUIT NUMBERS SEPARATED BY BACKSLASH INDICATE MULTIPLE BRANCH CIRCUITS. E2. MOUNTING DIMENSIONS ARE TO THE CENTER OF THE DEVICE OR OUTLET MEASURED ABOVE GRADE OR FINISHED FLOOR, UNLESS OTHERWISE NOTED. E3. CONTRACTOR SHALL CONFIRM ELECTRICAL DEVICE MOUNTING HEIGHTS WITH ARCHITECTURAL, INTERIOR DESIGN, ETC. DOCUMENTS, WHICH SHALL TAKE PRECEDENCE. L LOW VOLTAGE DIMMER SWITCH E3 OR 42" AFF E2 ELECTRICAL SYMBOL LEGEND E3 OR MATCH CONDITIONS SPECIAL PURPOSE RECEPTACLE(S) (WALL or RACK/FLOOR/CEILING)E3 H-1,3,5 HOMERUN TO PANEL "H" AND TERMINATED ON 1, 3 & 5 CIRCUITING INSTALLED CONCEALED OR ABOVE CEILING CIRCUITING INSTALLED CONCEALED IN SLAB OR BELOW GRADE (DASHED) E2 E2 E2 E2 E2 E2 E2 L1&L2 L1 L1 L1 L1 DESCRIPTION LIGHTING FIXTURE SYMBOL LEGEND N SMOKE DETECTOR HEAT DETECTOR 48" AFF F1 F3 NOTES: F1. MOUNTING HEIGHT IS TO CENTER OF DEVICE. F2. DEVICE SHALL BE MOUNTED AT +80" ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6" BELOW THE CEILING, WHICHEVER IS LOWER. MOUNTING HEIGHTS ARE TO BOTTOM OF DEVICE. STROBES SHALL BE 75CD, UNLESS OTHERWISE NOTED. F3. DOOR HOLD MAY BE INTEGRAL WITH DOOR CLOSURE. F2 F2 CARBON MONOXIDE DETECTOR FIRE PHONE WATER FLOW SWITCH TAMPER SWITCH END OF LINE TERMINATION FIRE ALARM REMOTE ANNUNCIATOR PANEL FIRE ALARM PANEL REMOTE RESET DOOR HOLD WALL MOUNTED STROBE WALL MOUNTED HORN OR SPEAKER WITH STROBE WALL MOUNTED HORN OR SPEAKER PULL STATION SMOKE ALARM DETECTOR SMOKE LASER DUCT DETECTOR SYMBOLS LISTED BELOW ARE FOR REFERENCE AND FOR THE USE IN UNDERSTANDING THE DESIGN INTENT. NOT ALL SYMBOLS LISTED BELOW ARE NECESSARILY USED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. SYMBOL(S) DESCRIPTION NOTES MOUNT HEIGHT FIRE ALARM SYMBOL LEGEND E3 OR 42" AFF SYMBOLS LISTED BELOW ARE FOR REFERENCE AND FOR THE USE IN UNDERSTANDING THE DESIGN INTENT. NOT ALL SYMBOLS LISTED BELOW ARE NECESSARILY USED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. L1&L2 L1&L2 L1&L2 L1&L2 L1&L2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 E3 E1 GROUND FAULT DUPLEX RECEPTACLE E3 OR 18" AFF E2 XX KEYNOTE TAG 1 KEY VALUE SMOKE ALARM WITH CARBON MONOXIDE DETECTOR GENERAL NOTES: (APPLIES TO ENTIRE DRAWING SET) 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL GOVERNING CODES, STANDARDS AND ORDINANCES AS ADOPTED AND ENFORCED BY THE AUTHORITY HAVING JURISDICTION. 2. DRAWINGS, IN GENERAL, ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO CONVEY, IN CONJUNCTION WITH THE COMPLETE CONTRACT DOCUMENTS, A COMPLETE AND FUNCTIONAL SYSTEM. COORDINATION OF WORK WITH OTHER TRADES IS REQUIRED BEFORE PROCEEDING WITH WORK. 3. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION FROM ARCHITECT BEFORE PROCEEDING. 4. CONTRACTOR SHALL PROVIDE A COMPLETE OPERATIONAL AND FUNCTIONING SYSTEM. CONTRACTOR SHALL PROVIDE CONNECTIONS TO OWNER, OR OTHER PARTY'S EQUIPMENT AND DEVICES, UNLESS OTHERWISE NOTED. 5. REFERENCE COMPLETE CONSTRUCTION DOCUMENTS (ARCHITECTURAL, MECHANICAL, PLUMBING, ETC.) PRIOR TO COMMENCING WORK FOR ADDITIONAL INFORMATION AND REQUIREMENTS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE OWNER'S/ARCHITECT'S ATTENTION BEFORE PROCEEDING WITH WORK. 6. CONTRACTOR SHALL MAINTAIN ON SITE, AVAILABLE FOR REVIEW, A MASTER SET OF MARKED UP DRAWINGS REFLECTING "AS BUILT" CONDITIONS. UPON CONCLUSION OF PROJECT, "AS BUILT" DRAWINGS SHALL BE TURNED OVER TO OWNER. 7. DETAILS AND SECTIONS ARE INTENDED TO BE TYPICAL AND INDICATE BASIC DESIGN INTENT AND SHALL APPLY TO SIMILAR SITUATIONS. ADAPTATIONS TO SPECIFIC PROJECT CONDITIONS MAY BE REQUIRED. BASIC DESIGN INTENT IS TO BE RETAINED. 8. AFTER COMPLETION OF WORK ALL ADDITIONAL MATERIALS REMAINING DUE TO CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF REMOVED FROM THE SITE IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, AND REGULATIONS UNLESS NOTIFIED OTHERWISE CONTRACTOR SHALL ALSO REMOVE ALL WASTE DEBRIS, RUBBISH, TOOLS, EQUIPMENT AND SURPLUS MATERIALS UPON COMPLETION OF WORK THROUGHOUT CONSTRUCTION, SITE SHALL BE ORGANIZED AND CLEANED BY CONTRACTOR ON A DAILY BASIS. 9. PENETRATIONS INTO OR THROUGH, OF EITHER VERTICAL OR HORIZONTAL FIRE RATED BARRIERS SHALL BE PROTECTED BY A SYSTEM LISTED BY A RECOGNIZED TESTING AGENCY. PROVIDE A DETAIL AND LISTING NUMBER PER NFPA 101 LIFE SAFETY CODE. 10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF EQUIPMENT AND DEVICES AT CEILING. IF AN ITEM IS NOT SHOWN SUBMIT RECOMMENDED LOCATION FOR ARCHITECT'S APPROVAL. 11. MATERIALS EXPOSED WITHIN SPACES ABOVE A CEILING BEING UTILIZED AS A RETURN AIR PLENUM SHALL BE NON-COMBUSTIBLE, OR SHALL HAVE A FLAME-SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50, AS DETERMINED IN ACCORDANCE WITH ASTM E84. 12. CONTRACTOR SHALL REVIEW CONSTRUCTION DOCUMENTS TO IDENTIFY MISCELLANEOUS POWER REQUIREMENTS AND PROVIDE CIRCUITING AS REQUIRED. COORDINATE POWER REQUIREMENTS WITH OTHER INSTALLERS. MISCELLANEOUS POWER REQUIREMENTS FOR CONTROL PANELS AND SMALL EQUIPMENT IS MANUFACTURER DEPENDENT AND MAY NOT BE SHOWN OR WILL BE DEFINED BY OTHERS. TYPICAL SYSTEMS INCLUDE, BUT NOT LIMITED TO: ·FIRE ALARM SYSTEMS - FACP POWER (DEDICATED CIRCUIT), FAAP POWER, REMOTE POWER SUPPLIES, DOOR HOLDS, ETC. ·BUILDING MANAGEMENT SYSTEMS - MASTER CONTROL PANEL, REMOTE CONTROL PANELS, REMOTE POWER SUPPLIES, ETC. ·DIRECT DIGITAL CONTROL SYSTEMS - MASTER CONTROL PANEL, REMOTE CONTROL PANELS, REMOTE POWER SUPPLIES, ETC. ·HVAC EQUIPMENT - CONTROL PANELS, VAV CONTROL POWER, SMOKE DAMPERS, FIRE/SMOKE DAMPERS, MOTORIZED DAMPERS, ETC. ·PLUMBING - CONTROL PANELS, IGNITER CIRCUIT POWER, LEAK DETECTION ETC. ·REFRIGERANT DETECTION AND PURGE SYSTEMS ·CARBON MONOXIDE DETECTION AND PURGE SYSTEMS ·CARBON DIOXIDE DETECTION SYSTEMS ·GENERATOR - PERIPHERAL EQUIPMENT (WATER JACKET HEATER, BATTERY CHARGER, ETC.) ·ELEVATOR - PERIPHERAL EQUIPMENT (CONTROL PANELS, ETC.) 13. PROVIDE GROUNDING CONDUCTOR FOR EACH CIRCUIT IN ADDITION TO ANY RACEWAY GROUNDING. 14. PROVIDE PERMANENT BARRIER PLATE IN SWITCH JUNCTION BOXES TO SEPARATE 120V AND 277V SYSTEMS PER NEC ARTICLE 404.8.B. 15. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 16. GFI DEVICES SHALL BE READILY ACCESSIBLE IN ACCORDANCE WITH NEC ARTICLE 210.8. SHOULD RECEPTACLES BE RENDERED INACCESSIBLE BY INSTALLATION OF EQUIPMENT (I.E. VENDING MACHINES, KITCHEN EQUIPMENT, ETC.), GFI PROTECTION SHALL BE PROVIDED BY THE CIRCUIT BREAKER AT THE PANEL. 17. OUTLET BOX HEIGHTS SHALL BE ADJUSTED TO AVOID INSTALLATION OF BOXES ON MULTIPLE SURFACE PLANES (I.E. TRANSITION OF TILE MOUNTED ON TOP OF SHEET ROCK). FACEPLATES SHALL BE INSTALLED SO AS TO COMPLETELY COVER THE OPENING AND SEAT AGAINST MOUNTING SURFACE PER NEC 404.9(A) AND NEC 406.5. COORDINATE CHANGES WITH OWNER/ARCHITECT. 18. FINAL SELECTION OF EQUIPMENT MAY VARY FROM BASIS OF DESIGN. CONTRACTOR IS TO COORDINATE EQUIPMENT BRANCH CIRCUIT REQUIREMENTS (VOLTAGE, AMPERAGE, CIRCUIT CONDUCTORS, OVER CURRENT PROTECTION, AND METHOD OF TERMINATION) WITH ACTUAL EQUIPMENT TO BE PURCHASED BEFORE COMMENCING ASSOCIATED WORK. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 7:46:11 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE0−01 08.14.18ELECTRICAL LEGENDS AND NOTES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SHEET INDEX NUMBER NAME E0-01 ELECTRICAL LEGENDS AND NOTES E0-02 LIGHT FIXTURE SCHEDULES E1-01A ELECTRICAL FLOOR PLAN - UNDERGROUND E1-01B ELECTRICAL FLOOR PLAN - LEVEL 01 - GROUND LEVEL E1-02 ELECTRICAL FLOOR PLAN - LEVEL 02 - PARKING LEVEL P2 E1-03 ELECTRICAL FLOOR PLAN - LEVEL 03 - PARKING LEVEL P3 E1-04 ELECTRICAL FLOOR PLAN - LEVEL 04 - PARKING LEVEL P4 E1-05 ELECTRICAL FLOOR PLAN - LEVEL 05 - PARKING LEVEL P5 E1-06 ELECTRICAL FLOOR PLAN - LEVEL 06 - PARKING LEVEL P6 E1-07 ELECTRICAL FLOOR PLAN - LEVEL 07 - PARKING LEVEL P7 E1-08 ELECTRICAL FLOOR PLAN - LEVEL 08 - PARKING LEVEL P8 E1-09 ELECTRICAL FLOOR PLAN - LEVEL 09-14 - TYPICAL OFFICE LEVELS O1-O5 E1-15 ELECTRICAL FLOOR PLAN - LEVEL 15-16 - TYPICAL OFFICE LEVELS O6-O7 E1-17 ELECTRICAL FLOOR PLAN - LEVEL 17 - INTERSTITIAL LEVEL E1-18 ELECTRICAL FLOOR PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 E1-19 ELECTRICAL FLOOR PLAN - LEVEL 19-29 - TYPICAL RESIDENTIAL UNIT LEVEL R2-R12 E1-30 ELECTRICAL FLOOR PLAN - LEVEL 30 - ROOF PLAN E1-31 ELECTRICAL FLOOR PLAN - LEVEL 31 - PENTHOUSE ROOF PLAN E2-01 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 01 - GROUND LEVEL E2-02 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 02 - PARKING LEVEL P2 E2-03 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 03-05 - TYPICAL PARKING LEVELS P3-P5 E2-06 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 06 - PARKING LEVEL P6 E2-07 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 07 - PARKING LEVEL P7 E2-08 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 08 - PARKING LEVEL P8 E2-09 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 09-14 - TYPICAL OFFICE LEVELS O1-O5 E2-18 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 E2-19 ELECTRICAL REFLECTED CEILING PLAN - LEVELS 19-29 - TYPICAL RESIDENTIAL LEVEL R2-R12 E3-01 ELECTRICAL UNIT PLANS E3-02 ELECTRICAL UNIT PLANS E3-03 ELECTRICAL UNIT PLANS E3-04 ELECTRICAL UNIT PLANS E3-05 ELECTRICAL UNIT PLANS E3-10 ELECTRICAL ENLARGED PLANS E4-01 ELECTRICAL RISER DIAGRAM E4-02 ELECTRICAL RISER DIAGRAM E4-03 ELECTRICAL RISER DIAGRAM E4-04 TYPICAL FIRE ALARM RISER E4-05A LIGHTING STAIRWELL RISER E4-05B LIGHTING STAIRWELL RISER E5-00A ELECTRICAL SCHEDULES E5-00B ELECTRICAL SCHEDULES E5-00C ELECTRICAL SCHEDULES E5-01A ELECTRICAL SCHEDULES E5-01B ELECTRICAL SCHEDULES E5-03 ELECTRICAL SCHEDULES E5-06 ELECTRICAL SCHEDULES E5-08 ELECTRICAL SCHEDULES E5-09 ELECTRICAL SCHEDULES E5-10 ELECTRICAL SCHEDULES E5-11 ELECTRICAL SCHEDULES E5-12 ELECTRICAL SCHEDULES E5-14 ELECTRICAL SCHEDULES E5-15 ELECTRICAL SCHEDULES E5-16 ELECTRICAL SCHEDULES E5-17 ELECTRICAL SCHEDULES E5-18 ELECTRICAL SCHEDULES E5-19 ELECTRICAL SCHEDULES E5-22 ELECTRICAL SCHEDULES E5-25 ELECTRICAL SCHEDULES E5-28 ELECTRICAL SCHEDULES E5-30 ELECTRICAL SCHEDULES E6-01 ELECTRICAL DETAILS E6-02 ELECTRICAL DETAILS E6-03 ELECTRICAL DETAILS Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1. CAPITAL LETTERS ADJACENT FEXTURES DESIGNATES FIXTURE TYPE IN LIGHT FIXTURE SCHEDULE. LOWER CASE LETTER DESIGNATES DIMMING ZONE OR SWITCH LEG. 2. SHADED CIRCLE IS TYPICAL INDICATOR FOR EGRESS LIGHTING. LIGHT FIXTURE SCHEDULE NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 10:56:05 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE0−02 08.14.18LIGHT FIXTURE SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION - 1 1 8 823456 AA B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.9 3.9 3.92.91.8 E 7.86.8 A.7 C.7.1 2.8 2.8 5.7 5.7 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 RESIDENTIAL LOBBY 133 OFFICE LOBBY 102 PARKING DECK ELEVATOR LOBBY 106 TELECOM 121 MAIN ELECTRICAL ROOM 124 EMERGENCY ELECTRICAL ROOM 125 RESIDENTIAL MAILROOM 126 BUILDING MAINTENANCE 130 FIRE PUMP ROOM 110 RECYCLING AREA 111 EMERGENCY GENERATOR ROOM 117 TRANSFORMER AREA 118 STAIR #2 ST2 FIRE COMMAND CENTER 108 MEP CLOSET O4 OFFICE MAILROOM 122 RESIDENTIAL SERVICE CORRID0R 128 5.9 D.2D.2 JANITOR’S CLOSET 123 5.3 5.3 RAMP 127 O1 TO1 O2 TO2 O3 TO3 RESIDENTIAL ELEV. LOBBY 132 ACCESS STAIR 131 SERVICE ELEVATOR LOBBY 119 TRASH COMPACTOR 113 LOADING DOCK 114 S1 TS1 ENTRY LOGGIA 101 SERVICE ENTRY 109 SERVICE DRIVE 115 BOH RESTROOM 134 MECH CLOSET 133 E.9 O4 TO4 R1 TR1 R2 TR2 R3 TR3 2.3 E.9 5.9 1 2121212121 212121212121212121212 E3-10 1 1 2121212121212 MAINTAIN 5 FEET BETWEEN DUCT BANKS: DUCT BANK TO BE 2 ROWS DEEP. 208V XFMR 1000KVA 480V XFMR 2500 KVA 480V C.T. 480V T.C. 208V T.C. GENERATOR MTR MTR RETAIL R1 R2 PROVIDE PROVISIONS FOR CONNECTION TO BUILDING FIRE ALARM SYSTEM FOR RETAIL AREA. PROVIDE PROVISION FOR 277V EMERGENCY POWER WITH TRANSFER MODULE. PROVIDE (2) 4" CONDUITS FOR RETAILPOWER BACK TO RETAIL METER. TOWER SWITCH PROVIDE CONDUIT FROM 480V C.T. CABINET TO PUMP ROOM FOR FIRE PUMP. REFER TO E4-02 FOR ADDITIONAL INFORMATION. UTILITY PRIMARY CONDUITS PER DUKE ENERGY STANDARDS. NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. PROVIDE 2" UNDERGROUND CONDUITS FOR FEATURE LIGHTING TBD ON SOUTH GRAHAM AND MLK. 8'x5/8" GROUND ROD PAD GROUND ROD(S) BOND TO REBAR 4/0 AWG BARE COPPER GROUND BAR 4/0 AWG BARE COPPER GROUND BAR BOND TO REBAR VAULT GROUNDING PER DUKE ENERGY STANDARDS. POWER NOTES: 1. REFER TO UTILITY COMPANY STANDARDS FOR ALL CONDUITS/DUCT BANKS ENTERING BUILDING. 2. REFER TO E4 SERIES FOR ADDITIONAL CONDUIT INFORMATION. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 12:04:19 PM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−01A 08.14.18ELECTRICAL FLOOR PLAN − UNDERGROUND401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-01A 1 ELECTRICAL FLOOR PLAN - UNDERGROUND PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION S S S S 3J J J JFSJJ J WPJ H S S S S S S FF F J J 1 1 8 823456 AA B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.9 3.9 3.92.91.8 E 7.86.8 A.7 C.7.1 2.8 2.8 5.7 5.7 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 RESIDENTIAL LOBBY 133 OFFICE LOBBY 102 PARKING DECK ELEVATOR LOBBY 106 5.9 D.2D.2 5.3 5.3 RAMP 127 O1 TO1 O2 TO2 O3 TO3 RESIDENTIAL ELEV. LOBBY 132 ENTRY LOGGIA 101 SERVICE DRIVE 115 E.9 O4 TO4 2.3 E.9 5.9 ATS-1 ATS-2 MSB-HOUSET-EL1E1H1E1L1 T-1L1 1L1 1H1DFCU-01-01EH-02 F-01-01 EH-02 FCU-01-01 EH-03 FP-1 BP-1 BP-2EH-02F-01-03 EH-03 DFCU-01-02 DFCU-01-03 ATS-3Z1H11LR R1 R2 FACP FAAP FAAPSP-4 SP-3SP-2SP-5SP-1 TURNSTILE 208V XFMR 1000KVA 480V XFMR 2500 KVA EH-01 EH-01EH-01METERIRP-1JP-1 COMP-2750KW DIESEL GENERATOR 196"L X 74"W X 96"H 480V C.T. 480V T.C. 208V T.C. MTR MTR RTL 1HTV1LTV700 GALLON UNDERGROUND TANK FOR TRANSFORMER RUPTURE LOCATION TO BE COORDINATED WITH STRUCTURAL AND ELECTRICAL CONDUITS. DIRECTORY 1 2121212121 212121212121212121212 F-01-04 F-01-05 T-1LTV1DP E3-10 2 EH-06 EH-07 EH-08 EH-01 ADA DOOR OPENER POWER 1 2121212 1L3 FCU-01-02 EH-05 1 21212 F-01-06 F-01-07 SPRINKLER PANEL ELEVATOR CONTROL PANEL ELEVATOR COMM SMOKE CONTROL PANEL SMOKE CONTROL PANEL STAIR RELEASE PANEL ATS PANEL IRRIGATION CONTROLLER GENERATOR PANEL FIRE PUMP CONTROLLER OVERHEAD DOOR 1H1 - 2 WH-2 1LTV - 1 1LLR T-1LLR 1L1 - 11,13 1L1 - 8 1L1 - 10,12 1L1 - 15,17 1L1 - 7,9 1L1 - 16 1H1 - 4 1H1 - 6 GENERATOR - 4 1H1 - 7 1L3 - 1 1L3 - 2 1L1 - 20,22 1H1 - 91H1 - 8 1L1 - 24 1L1 - 27 1L1 - 26 1L1 - 25 SP-61L1 - 36,38 1L1 - 37,39 1H1 - 10 1H1 - 11 1L1 - 40 1L1 - 29,31 1L1 - 33,35 1L1 - 32,34 1LLR - 2 1LLR - 1 1LLR - 3 1H1 - 12,14,16 EH-02 EH-02 NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. 1L1 - 23 MODF-01-02MODMODMOD1H1 - 18,20,22 1L1 - 42,44 1L1 - 41,43 1H1 - 21 HOIST DISCONNECT 1HTV - 1,3,5 ST-1 1LR - 13,15,17 1LR - 14,16,18 1LR - 1,3,5 1L1 - 48 1H1 - 23 1H1 - 24 1L1 - 49 SLAB LEAVE OUT COLD DARK SHELL TEMPORARY MEANS OF EGRESS DOCK LEVELER 1L1 - 62,64 DOCK LEVELER CONTROL PARKING GATEPARKING PAYCENTER1L1 - 63,651L1 - 66,68EH-021H1 - 27 1L1 - 14 1L1 - 45 1L1 - 70 PROVIDE ELEVATED WALKWAY AROUND GENERATOR. 1LLR - 4 TOWER 1L1 - 28,30 RETAIL 1L1 - 71 1L1 - 73 1L1 - 72 1L1 - 47 1L1 - 75 1L1 - 74 1L1 - 76 1L1 - 77 ELEVATOR SHAFT LIGHT SWITCHES STUB IN FIRE ALARM CIRCUITS FOR FUTURE BUILDOUT. STUB IN 1"C FROM E1H1 LIFE-SAFETY. 1 2 2 2 1L1 - 78 1L2 PROVIDE REMOVABLE WALL FOR GENERATOR . 1LTV - 2,4 OIL TANK SUMP PUMP ADA DOOR OPENER POWER 3 1L1 - 79 1L1 - 80,82 TRASH COMPACTOR 1L1 - 46 1L1 - 81 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: COORDINATE POWER AND CONDUIT REQUIREMENTS FOR TURNSTILE EQUIPMENT WITH EQUIPMENT MANUFACTURER. COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS. SUMP PUMP CONTROLLER(S). REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION AND ADDITIONAL INFORMATION. ADA DOOR OPENER(S). REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS. DOOR POWER. COORDINATE POWER REQUIREMENTS WITH EQUIPMENT MANUFACTURER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 3 4 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:42:34 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−01B 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 01 − GROUND LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-01B 1 ELECTRICAL FLOOR PLAN - LEVEL 01 - GROUND LEVEL 1 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 3 4 4 FEFEFE FEFEFF F S S S S SS 1 1 8 823456 AA B E.0.7 FF 7 C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 E 7.86.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 STAIR #2 ST2 PARKING DECK ELEVATOR S1 RESIDENTIAL / FIREMANS ELEVATOR LOBBY 207 STAIR #1 ST1 5.9 D.2 D.2 5.3 5.3 ELECTRICAL ROOM 208 TELECOM ROOM 209 O1 TO1 O2 TO2 O3 TO3 15 15 16 E.9 PARKING DECK ELEVATOR VESTIBULE 210 O4 TO4 DRY SPRINKLER ROOM 206 R1 TR1 R2 TR2 R3 TR3 2.3 E.9 5.9 DCU-01-02 DCU-01-01 CU-01-01 CU-01-02 F-02-01 EH-01EH-04 COMP-1 EH-01 R1 R2 O DFCU-XX-01 DCU-01-03 1H1 - 15,17,19MODFSD FSDCAR CHARGING 3L1 - 1,33L1 - 13 3H1 - 5 3H1 - 12 3H1 - 7 1L1 - 51,53 1L1 - 50 1L1 - 52,54 1L1 - 55,57 1L1 - 56,58 1L1 - 59,61 #10 #10 #10 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:42:49 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−02 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 02 − PARKING LEVEL P2401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-02 1 ELECTRICAL FLOOR PLAN - LEVEL 02 - PARKING LEVEL P2 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FF S S F S S 1 1 8 823456 AA B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.86.8 A.7 2.8 2.8 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 FIREMANS ELEVATOR LOBBY 307 TELECOM ROOM 309 PARKING DECK ELEVATOR S1 STAIR #2 ST2 STAIR #1 ST1ELECTRICAL ROOM 308 5.9 D.2D.2 5.3 5.3 O3 TO3 O1 TO1 O2 TO2 PARKING DECK ELEVATOR VESTIBULE 310 O4 TO4 DRY SPRINKLER ROOM 306 R1 TR1 R2 TR2 R3 TR3 E.9 5.9 DFCU-XX-01 T-3L1 3H1 3L1 E3H1EH-01R1 R2 O EH-04 3H1 - 1 3H1 - 8 3L1 - 6,8 3L1 - 14 DCU-XX-01 DCU-XX-01 DCU-03-02CU-01-06CU-01-04CU-01-03CU-01-05?3L1 - 5,73L1 - 9,113L1 - 19,213L1 - 23,253L1 - 20,223L1 - 27,293L1 - 24,263L1 - 28 #10 #10 #10 DFCU-03-02 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:42:56 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−03 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 03 − PARKING LEVEL P3401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-03 1 ELECTRICAL FLOOR PLAN - LEVEL 03 - PARKING LEVEL P3 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION F FS S F S S 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 R1 R2 OEH-01EH-04 3H1 - 10 3H1 - 3 CAR CHARGING 3L1 - 10,12 3L1 - 16 3L1 - 18 DCU-XX-013L1 - 2,4DFCU-XX-01 #10 #10 #10 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:43:05 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−04 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 04 − PARKING LEVEL P4401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-04 1 ELECTRICAL FLOOR PLAN - LEVEL 04 - PARKING LEVEL P4 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FEFEFE FES FS F F S S 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 EH-01 R1 R2 O EH-04 6H1 - 2 CAR CHARGING 6L1 - 2,4 6L1 - 5 O3 TO3 O4 TO4 O1 TO1 O2 TO2 ELECTRICAL ROOM 508 TELECOM ROOM 509 STAIR #1 ST1 R3 TR3 R1 TR1 R2 TR2 RESIDENTIAL / FIREMANS LOBBY 507 PARKING DECK ELEVATOR S1STAIR #2 ST2 DRY SPRINKLER ROOM 506 DCU-XX-016H1 - 4DFCU-XX-01 6L1 - 10,12 6L1 - 5 #10 #10 #10 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:43:17 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−05 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 05 − PARKING LEVEL P5401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-05 1 ELECTRICAL FLOOR PLAN - LEVEL 05 PARKING LEVELS P5 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FEFEF F S S FS S 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 6L1 - 1,3 CAR CHARGING DFCU-XX-01EH-016H1 - 2 EH-04 6H1 - 7 DFCU-06-02 R2 O R1 E6H1 6L1 T-6L1 6H1 O2 TO2 O1 TO1 O3 TO3 O4 TO4 ELECTRICAL ROOM 608 TELECOM ROOM 609 R3 TR3 RESIDENTIAL / FIREMANS LOBBY 607 R2 TR2 R1 TR1 DRY SPRINKLER ROOM 606 PARKING DECK ELEVATOR S1STAIR #2 ST2 6L1 - 9 DCU-06-02 DCU-XX-01 1L1 - 21 6L1 - 11,13 6L1 - 14,16 #10 #10 6L1 - 15 #10 #10 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:43:30 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−06 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 06 − PARKING LEVEL P6401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-06 1 ELECTRICAL FLOOR PLAN - LEVEL 06 - PARKING LEVEL P6 Date Issue/Revision FS F F S S S 1 1 8 823456 AA B B E.0.7 FF 7 C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 D.7 E 7.86.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 5.9 D.2D.2 5.3 5.3 EH-01 R1 R2 O WH-3 8L1 - 34,36 8H1 - 2 CAR CHARGING 8L1 - 2,4 O3 TO3 O4 TO4 ELECTRICAL ROOM 708 R3 TR3 STAIR #1 ST1 FIREMANS ELEVATOR LOBBY 707 R2 TR2 R1 TR1 O1 TO1 O2 TO2 DRY SPRINKLER ROOM 706 PARKING DECK ELEVATOR OVER RUN S1 STAIR #2 ST2 DOG WASH 713 TELECOM ROOM 709 8L1 - 38 8L1 - 40 8L1 - 42 DFCU-07-03 PARKING DECK ELEVATOR 1 DCU-07-03 6L1 - 6,8 7LLRT-7LLRDFCU-XX-01 F-07-01 DFCU-07-02 PARKING DECK LEGALLY REQUIRED TROUGH #10 #10 #10 #10 PARKING DECK LEGALLY REQUIRED TROUGH-7,9,11 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:43:46 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−07 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 07 − PARKING LEVEL P7401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-07 1 ELECTRICAL FLOOR PLAN - LEVEL 07 - PARKING LEVEL P7 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION DN UP S F FF F SSS 1 1 8 823456 AA B E.0.7 FF C.1 D.1 E.8 A.6.1 C D 4.93.92.91.8 A.3 E 7.86.8 A.7 2.8 2.8 5.7 5.7 B.8B.8 D.4D.4 C.8C.8 C.9C.9 B.1 7.1 5.9 D.2D.2 5.3 5.3 5.9 F-08-01 DFCU-XX-01 T-8L1 8H18L1 EH-03 EH-01 DCU-XX-01DCU-07-02DCU-XX-01EH-03 WALKWAY ABOVE DRIVE AISLE DN TO PREVIOUS LEVEL STAIR #1 ST1 O2 TO2 O1 TO1 O3 TO3 O4 TO4 DRY SPRINKLER ROOM 806 RESIDENTIAL FIREMANS LOBBY 807 STAIR #2 ST2 STAIR PRESSURIZATION 811 EH-03 EH-03 EH-03 EH-03EH-03 EH-03 EH-03 EH-03EH-03 EH-03 EH-03 R1 R2 O MOD 8L1 - 6,8 8L1 - 9,11 8L1 - 1,3 8L1 - 13,15 8H1 - 4,6,8 8L1 - 14,16 8L1 - 18,20 8L1 - 17,19 8L1 - 21,23 8L1 - 25,278L1 - 22,248L1 - 33,35 8L1 - 29,31 8L1 - 30,32 DFCU-08-02 CAR CHARGING 8L1 - 37,39 END OF PARKING DECK R3 TR3 R1 TR1 R2 TR2 8L1 - 22,248L1 - 5,7 8H1 - 2 8L1 - 10 DCU-08-021L1 - 67,698L1 - 26,288L1 - 41,438L1 - 12 #10 #10 8L1 - 12 #10 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:05 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−08 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 08 − PARKING LEVEL P8401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-08 1 ELECTRICAL FLOOR PLAN - LEVEL 08 - PARKING LEVEL P8 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE FECFVC FEFS S S F S F1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 E9H1 9L1A9L1C T-9L1 9H1 SCU-XX-01 1 21212121212121212 R1 R2 O EH-09 EH-09 EH-09 EH-09 EH-09 EH-09 1 212 WH-O CP-O 9H1 - 2,4,6 9H1 - 8 9H1 - 7 9H1 - 9 9H1 - 11 9H1 - 10 9H1 - 12 9L1A - 2 9L1A - 4 F-XX-01 PIU-XX-01 MOD FSDFSDMOD 9L1A - 1 9L1A - 8 9L1A - 3 9L1A - 6 9L1A - 10 9L1A - 5,7 9L1A - 12 9L1B9L1A - 9 9L1A - 11 SD FD FD FD 9L1B - 2 9L1B - 4 9L1B - 6 STAIRWELL ONLY PRESENT ON OFFICE LEVEL 1. POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:09 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−09 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 09−14 − TYPICAL OFFICE LEVELS O1−O5401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-09 1 ELECTRICAL FLOOR PLAN - LEVEL 09-14 - TYPICAL OFFICE LEVELS O1-O5 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE FEC FECFVC FEF FF S S S S 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 SCU-XX-01 R1 R2 O 15H1F-XX-01PIU-XX-01 PIU-XX-03 PIU-XX-02 PIU-XX-05 PIU-XX-04 15L1A15L1B15L1C 15H1 - 2,4,6 15H1 - 7 15H1 - 8 15L1A - 2 15H1 - 9 15L1A - 6 15L1A - 4 15L1A - 1 15L1A - 10 15L1A - 12SD MODMODFSDFSD 15H1 - 10 15L1A - 5 15L1A - 3 ? c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:17 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−15 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 15−16 − TYPICAL OFFICE LEVELS O6−O7401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-15 1 ELECTRICAL FLOOR PLAN - LEVEL 15-16 - TYPICAL OFFICE LEVELS O6-O7 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION F FFFF S S S S 1 1 8 823456 AA B B E.0.7 FF 7 C.1 D.1 E.8 B.9 C D 3.92.91.8 A.3 7.86.8 A.7 C.7.1 D.0.5 2.8 2.8 5.7 5.7 B.8 B.8 D.4D.4 B.1 C.2 7.1 5.9 D.2D.2 5.3 5.3 C.7.2 5.9 17H1 ERU-01 F-17-01DFCU-17-0117LP1 EH-02 EH-02 EH-02 T-17LP1 T-LAM1 R1 R2 UTILITY TRANSFER AREA 1713 UTILITY TRANSFER AREA 1713 UTILITY TRANSFER AREA 1713 POOL PUMP ROOM 1705 UTILITY TRANSFER AREA 1713 STAIR #2 ST2 STAIR #2 ST2 STAIR #1 ST1 RESIDENTIAL SERVICE / FIREMANS ELEVATOR LOBBY 1707 5000A BUSO T-17LLR 17LLR EH-01 F-17-03 F-17-02 EH-01EH-02 DFCU-17-02EH-02 EH-02 EH-02 EH-02 EH-02 EH-02 17H1 - 12 17H1 - 16 17H1 - 14 17H1 - 19 17H1 - 27 17H1 - 15 17H1 - 8 17H1 - 10 17LP1 - 3 17H1 - 18 17H1 - 13 17H1 - 20 OFFICE ELEVATOR 1 OFFICE ELEVATOR 2 OFFICE ELEVATOR 4 OFFICE ELEVATOR 3 MOD FSD 17H1 - 1717H1 -21,23,2517LP1 - 1 17LP1 - 2 R2 ERU-01-HEATER ?? ERU-01-HEAT WHEEL MOTOR ? ? ?? ERU-01-OAU SUPPLY FAN MOTOR ERU-01 RETURN AIR FANS ERU-01-SUPPLY FAN MOTOR ?? ? 17LP1 - 5 17LP1 - 6 17LP1 - 7 17H1 - 22,24,26 17H1 - 29,31,33 17LP1 - 8 17H1 - 28,30,32 17H1 - 35,37,39 17LR R1 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:21 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−17 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 17 − INTERSTITIAL LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-17 1 ELECTRICAL FLOOR PLAN - LEVEL 17 - INTERSTITIAL LEVEL Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE F FF S SS S J 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 5.9 ? F-18-02 LAM2 LAM1 R2 R1 EH-01F-18-01 SHADED AREAS WILLBE APPLIED FOR IN SEPERATE PERMITWH-119L1 - 1,3 1H1 - 13 19L1 - 6 19L1 - 10 19L1 - 8 19L1 - 14 19L1 - 10 WH-4 WPWPEH-03EH-03FSDFSDFSDFSDFSDLAM1 - 1,3 POOL CHAIR LIFT FSD LAM1 - 2,4 LAM1 - 6,819L1 - 2 LAM1 - 5 <unnamed> LAM2 - 1,3 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:26 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−18 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 18 − AMENITY/RESIDENTIAL LEVEL R1401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-18 1 ELECTRICAL FLOOR PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE FEC FECFS F F J J S 3J S S 1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 19H1 E19H1 T-19L1 T-E19L119L1 E19L1 FSD(2) FSD(2) R1 R2 19L1 - 9 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:31 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−19 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 19−29 − TYPICAL RESIDENTIAL UNIT LEVELR2−R12401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-19 1 ELECTRICAL FLOOR PLAN - LEVEL 19-29 - TYPICAL RESIDENTIAL UNIT LEVELS R2-R12 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FEF WP WPWPJ FWP WPWPWP WP WPWP WP S S S S FE1 823456 A B E.0.7 F 7 C.1 D.1 E.8 A.6.1 B.9 C D 4.93.92.91.8 A.3 D.7 E E.2 7.8 5.8 6.8 A.7 C.7.1 D.0.5 2.8 5.7 B.8 D.4 C.8 C.9 B.1 A.1 7.9 6.7 C.2 7.1 4.95 5.9 D.2 5.3 C.7.2 E.9 P-05 P-04 P-06 OAU-02 F-R-02 CT-0130H1T-30L1 30L1EH-02 ET-01DCU-R-02HX-01 EH-02 F-PH-01 OAU-01 DFCU-R-01 FAA LIGHTING DFCU-R-02 RLLR T-RLLRDCU-R-01DCU-17-01DCU-17-02? CU-ACU-ACU-ACU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-ACU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-18-06 CU-A CU-A CU-A CU-A CU-A CU-ACU-B CU-BCU-B CU-BCU-BCU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-B CU-18-03 CU-18-02CU-18-01 CU-ACU-ACU-A CU-ACU-ACU-ACU-ACU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-ACU-A CU-A CU-A CU-B CU-B CU-A CU-A CU-ACU-BCU-B CU-A CU-A CU-B CU-B CU-A CU-ACU-A CU-B CU-B CU-B CU-A CU-A CU-A CU-A CU-A CU-ACU-ACU-ACU-ACU-A CU-A CU-A CU-ACU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-A CU-ACU-A CU-ACU-A CU-A CU-A CU-A CU-A CU-18-04 CU-18-05 CU-A WP 30H1 - 2,4,6 30H1 - 1,3,5 30H1 - 22,24,26 30H1 - 19,21,23 30L1 - 1 30H1 - 20 30L1 - 2 P-03P-02P-01 RESIDENTIAL LEGALLYREQUIRED TROUGH30H1 - 8 30H230H1 - 7,9,11 MODMODCU-A FSDFSD30L1 - 11,1330L1 - 6,830L1 - 10,1230L1 - 7,9CU-A CU-A CU-A CU-A 30L1 - 5 30L1 - 18,20 30L1 - 15,17 30L1 - 14,16 30H2 - 2,4,6 30L1 - 19,21 30H2 - 13,15,17 MODRESIDENTIALELEVATOR 1RESIDENTIALELEVATOR 2RESIDENTIALELEVATOR 330L1 - 4 1 E1-30 2 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: POWER CIRCUIT HAS TO BE IN FIRE RATED ENCLOSURE OR 2 HR RATED CABLE. DESIGN INTENT IS TO ROUTE POWER CIRCUIT WITHIN STAIR ENCLOSURE AND AND USE 2 HOUR RATED CABLE ONLY OUTSIDE STAIR ENCLOSURE. FAA LIGHTING VERIFY LOCATION WITH ARCHITECT. KEYNOTES: 1 2 2 5 6 D.1 B.9 C D D.0.5 5.7 B.8 C.8 C.9 C.2 4.95 D.2 5.3 C.7.2 STW E1H1 - 10 STW E1H1 - 11 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 P2 E19H1 - 4 AWP E19H1 - 4 AWP E19H1 - 4 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/14/2018 9:58:05 AM C:\Users\Kelly\Documents\~REALTIME PROJECT BACKUP\17062 - ELECTRICAL_v17_Kelly.rvtE1−30 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 30 − ROOF PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-30 1 ELECTRICAL FLOOR PLAN - LEVEL 30 - ROOF PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION N SCALE: 1/8" = 1'-0"E1-30 2 ELECTRICAL FLOOR PLAN - LEVEL 30 - PENTHOUSE LIGHTING PLAN 5 6 D.1 B.9 C D D.0.5 5.7 B.8 C.8 C.9 C.2 4.95 D.2 5.3 C.7.2 6.4 F-R-01 WP 30H2 - 14,16,18 30L1 - 22 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: POWER CIRCUIT HAS TO BE IN FIRE RATED ENCLOSURE OR 2 HR RATED CABLE. DESIGN INTENT IS TO ROUTE POWER CIRCUIT WITHIN STAIR ENCLOSURE AND AND USE 2 HOUR RATED CABLE ONLY OUTSIDE STAIR ENCLOSURE. FAA LIGHTING VERIFY LOCATION WITH ARCHITECT. KEYNOTES: 1 2 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:44:45 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE1−31 08.14.18ELECTRICAL FLOOR PLAN − LEVEL 31 − PENTHOUSE ROOF PLAN401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E1-31 1 ELECTRICAL FLOOR PLAN - LEVEL 31 - PENTHOUSE ROOF PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 FEC FECFECFEFE FEFECFVC OS 333OSOS33 STW AX2 P1 E1H1 - 8 P1 1H1 - 26 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 1H1 - 26 P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 P1 1H1 - 26P21H1 - 28P2 K K P2 EPLEPLEPL EPL EPL EPL P1 E1H1 - 8 P1 1H1 - 26 P1 E1H1 - 8 EPL EPL EPL EPL EPL GENERATOR RC-1 E1L1 - 5 RC-1 RC-1 E1L1 - 5 B B B B B CP-6 RC-1P2 P2 E1H1 - 16 P2 E1H1 - 16 B B B K KK K E1L1 - 3 P2 E1H1 - 14 P2 E1H1 - 14 P2 P2 P2 E1H1 - 14 P1 1H1 - 26 P1 E1H1 - 8 AWP AWP AWPAWP K E1L1 - 3 NOTE: THIS SPACE WILL BE APPLIED FOR IN SEPARATE PERMIT. ? ? ? ? P2 E1H1 - 16 A AX1 AX1 AX1AX1 AX1 AX1 AX1 AX1 AX2 AX2 P2 1H1 - 28 AX2 AX2 AX2 AX2 AX1 A A A A H P21H1 - 28P2 E1H1 - 16 P21H1 - 28C 1H1 - 28 C 1H1 - 28 C 1H1 - 28 C E1H1 - 16 C E1H1 - 16 C E1H1 - 16 EPL 1LLR - 6 EPL 1LLR - 6 EPL 1LLR - 6 EPL 1LLR - 6 EPL 1LLR - 5 EPL 1LLR - 5 EPL 1LLR - 5 EPL 1L1 - 60 AWP E1H1 - 16 AWP E1H1 - 16 P2E1H1 - 16P2 E1H1 - 16 P2 1H1 - 28 P2 1H1 - 28 P2 1H1 - 28 P2 E1H1 - 16 P2 1H1 - 28 P2 E1H1 - 16 1 2 2 2 2 2 1 1DP - 2 AA A AAA AA A A A A 1DP - 4 1DP - 1 1DP - 5 F C1DP - 3C1LLR - 9C1LLR - 9C1DP - 31L1 - 18 AWP AWPAWP AWP 1H1 - 29 1L1 - 1 1H1 - 28 1H1 - 30 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 12:04:24 PM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−01 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 01 − GROUND LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085N SCALE: 1/8" = 1'-0"E2-01 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 01 - GROUND LEVEL Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: STW E1H1 - 12 STW E1H1 - 13 STW E1H1 - 10 STW E1H1 - 11 P2 1H1 - 31 P2 E3H1 - 1 P2 E3H1 - 1 CM-2 E1L1 - 1 CM-2 E1L1 - 1 STAIR #1 ST1 O2 TO2 O1 TO1 O3 TO3 O4 TO4 STW E1H1 - 17 P1 1H1 - 31 P1 E1H1 - 7 P1 E1H1 - 7 P1 E1H1 - 7 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 E1H1 - 7 P1 1H1 - 31 P1 E1H1 - 7 P1 E1H1 - 7 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P2 1H1 - 31 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 E1H1 - 7 P1 E1H1 - 7 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 1H1 - 31 P1 1H1 - 31 P1 E1H1 - 7 P1 E1H1 - 7 P1 1H1 - 31 ELECTRICAL ROOM 208 TELECOM ROOM 609 R3 TR3 RESIDENTIAL / FIREMANS LOBBY 207 R2 TR2 R1 TR1 DRY SPRINKLER ROOM 606 PARKING DECK ELEVATOR S1STAIR #2 ST2 1 2 2 2 2 2 P2 E1H1 - 7 P2 1H1 - 31 AX2 AX2 AX2 AX2 AX2 AX2 PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 12:04:28 PM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−02 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 02 − PARKING LEVEL P2401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-02 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 02 - PARKING LEVEL P2 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION O3 TO3 O4 TO4 O2 TO2 O1 TO1 STW E1H1 - 13 STW E1H1 - 11 STW E1H1 - 10 P2 E3H1 - 1 P2 E3H1 - 1 P2 3H1 - 9 STW E1H1 - 12 P1 3H1 - 11 P1 E3H1 - 1 P1 E3H1 - 1 P1 E3H1 - 1 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 3H1 - 11 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P2 3H1 - 9 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 E3H1 - 1 P1 3H1 - 11 P1 3H1 - 11 P1 E3H1 - 1 P1 E3H1 - 1 P1 3H1 - 11 CM-2 E1L1 - 1 CM-2 E1L1 - 1 ELECTRICAL ROOM 308 TELECOM ROOM 309 R3 TR3 RESIDENTIAL / FIREMANS LOBBY 307 R2 TR2 R1 TR1 DRY SPRINKLER ROOM 306 PARKING DECK ELEVATOR S1STAIR #2 ST2 P2 3H1 - 11 STAIR #1 ST1 P2 E3H1 - 1 AX2 AX2 AX2 AX2 AX2 AX2 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 12:04:37 PM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−03 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 03−05 − TYPICAL PARKINGLEVELS P3−P5401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-03 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 03-05 - PARKING LEVEL P3 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 1 2 2 2 2 2 ELECTRICAL ROOM 608 TELECOM ROOM 609 R3 TR3 RESIDENTIAL / FIREMANS LOBBY 607 R2 TR2 R1 TR1 DRY SPRINKLER ROOM 606 PARKING DECK ELEVATOR S1STAIR #2 ST2 STAIR #1 ST1 CM-2 E1L1 - 1 CM-2 E1L1 - 1 P2 E6H1 - 1 P2 6H1 - 6 STW E1H1 - 12 STW E1H1 - 13 STW E1H1 - 11 STW E1H1 - 10 P2 E6H1 - 2 P2 E6H1 - 2 P2 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 E6H1 - 1 P1 E6H1 - 1 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 E6H1 - 1 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P2 6H1 - 6 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 E6H1 - 1 P1 E6H1 - 1 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 6H1 - 6 P1 6H1 - 6 P1 E6H1 - 1 P1 E6H1 - 1 P1 6H1 - 6 CM-2 E1L1 - 1 CM-2 E1L1 - 1 AX2 AX2 AX2 AX2 AX2 AX2 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 12:04:58 PM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−06 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 06 − PARKING LEVEL P6401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-06 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 06 - PARKING LEVEL P6 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 1 222 2 OSSTW P2 8H1 - 9 P2 E6H1 - 2 P2 E6H1 - 2 P1 8H1 - 7 P1 E9H1 - 5 P1 8H1 - 7 O3 TO3 O4 TO4 O1 TO1 O2 TO2 ELECTRICAL ROOM 708 TELECOM ROOM 709 R3 TR3 RESIDENTIAL / FIREMANS LOBBY 707 R2 TR2 R1 TR1 DRY SPRINKLER ROOM 706 PARKING DECK ELEVATOR S1STAIR #2 ST2 STAIR #1 ST1 END OF PARKING DECK ABOVE STW E1H1 - 13 STW E1H1 - 11 P1 8H1 - 9 P1 E9H1 - 5 P1 E9H1 - 5 P1 E9H1 - 5 P1 E9H1 - 5 P1 8H1 - 10 P1 8H1 - 10 P1 E9H1 - 5 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 8H1 - 9 P1 E9H1 - 5 P1 E9H1 - 5 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 8H1 - 9 P1 8H1 - 9 P1 8H1 - 9 P1 E9H1 - 5 P2 8H1 - 10 P1 8H1 - 9 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 E9H1 - 5 P1 E9H1 - 5 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 P1 8H1 - 9 P1 E9H1 - 5 P1 8H1 - 9 CM-2 E1L1 - 1 CM-2 E1L1 - 1 AX2 CP-4 AX2 AX2 AX2 AX2 AX2 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:56:25 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−07 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 07 − PARKING LEVEL P7401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-07 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 07 - PARKING LEVEL P7 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 1 2 2 2 2 2 O1 TO1 O2 TO2 O4 TO4 O3 TO3 STW E1H1 - 12 STW E1H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 E6H1 - 2 P3 E6H1 - 2 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 E6H1 - 2 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 E6H1 - 2 P3 E6H1 - 2 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 E6H1 - 2 P3 E6H1 - 2 P3 8H1 - 10 P3 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P2 8H1 - 10 P3 8H1 - 10 P3 E6H1 - 2 P3 8H1 - 10 P3 E6H1 - 2 P3 E6H1 - 2 P3 8H1 - 10 STW E1H1 - 13 R3 TR3 FIREMANS ELEVATOR LOBBY 707 R1 TR1 R2 TR2 ELECTRICAL ROOM 708 STAIR #1 ST1 DRY SPRINKLER ROOM 706 CM-2 E1L1 - 1 CM-2 E1L1 - 1 P3 8H1 - 10 P3 E6H1 - 2 STW E1H1 - 11 P2 E6H1 - 2 P2 E6H1 - 2 P2 8H1 - 10 CP-4 STW STW E9H1 - 3 STW E9H1 - 3 STW E9H1 - 3 STW E9H1 - 3 STW E9H1 - 3 STW E9H1 - 3 STW E9H1 - 3 STAIR #2 ST2 AX2 AX2 AX2 AX2 AX2 AX2 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:56:34 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−08 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 08 − PARKING LEVEL P8401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-08 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 08 - PARKING LEVEL P8 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE FECFVC FESTW K B B K KKK K K K K B K STW N N N N N N 9H1 - 13 N E9H1 - 6 N 9H1 - 13 N E9H1 - 6 N 9H1 - 13 N E9H1 - 6 N N NNNNNN N E9H1 - 6 N 9H1 - 13 P2 9H1 - 13 P2 E9H1 - 6 P2 E9H1 - 6 P2 9H1 - 13 P2 9H1 - 13 P2 E9H1 - 6 P2 E9H1 - 6 P2 9H1 - 13 STAIRWELL ONLY PRESENT ON OFFICE LEVEL 1. AX1 AX1 AX1 AX1 AX1 AX1 AX1AX1 AX1 9L1A - 13 9H1 - 15 9H1 - 14 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 P2 E9H1 - 4 K 9L1A - 15 K 9L1A - 15 K 9L1A - 15 K 9L1A - 15 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 9L1A - 13 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 K E10L1 - 2 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:56:41 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−09 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 09−14 − TYPICAL OFFICE LEVELSO1−O5401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-09 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 09-14 - OFFICE LEVELS O1-O5 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 1 1 1 2 2 2 2 FEFEFE1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: STW E9H1 - 2 STW E16H1 - 4 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 E16H1 - 6 A4 E16H1 - 6 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 A4 A4 E16H1 - 6 A4 E16H1 - 6A4 16H1 - 14 A4A4 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 A4 E16H1 - 6 A4 E16H1 - 6 A4 A4 A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 16H1 - 14A4 E16H1 - 6 A4 16H1 - 14 A4 E16H1 - 6 A4 E16H1 - 6 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:56:48 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−17 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 17 − INTERSTITIAL LEVEL401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-17 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 17 - INTERSTITIAL LEVEL Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION FECFECCM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 WS-3 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-2 E19L1 - 7CM-2 E19L1 - 7 CM-2 E19L1 - 7 CM-2 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-2 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-2 19L1 - 16 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-1 19L1 - 16 CM-1 E19L1 - 7 CM-2 19L1 - 16 CM-2 E19L1 - 7 CM-2 19L1 - 16 CM-2 19L1 - 16 AX1 STW E1H1 - 11 AX1 STW E16H1 - 2 STW E16H1 - 4 AX1 AX1 AX1 P2 E19H1 - 2 P2 E19H1 - 2 P2 E19H1 - 2 AX1 STW E1H1 - 10 STW E1H1 - 11 WS-2 19L1 - 16 RC-1 E19L1 - 7 RC-1 19L1 - 16 RC-1 19L1 - 16 RC-1 E19L1 - 7 WS-2 19L1 - 16 P2 E19H1 - 2 RC-1 E19L1 - 7 STW E1H1 - 10 AX1 AX1 AX1 AX1AX1 (16) IN-WALL RECESS WALL SCONCES. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS. DP3 LAM2 - 2 DP3 LAM2 - 2 DP3 LAM2 - 2 RC-1 RC-1 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:56:56 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−18 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVEL 18 − AMENITY/RESIDENTIALLEVEL R1401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-18 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 18 - AMENITY/RESIDENTIAL LEVEL R1 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FE FEC FECSTAIR #2 ST2 STAIR #1 ST1 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 19L1 - 17 WS-3 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 CM-1 E19L1 - 9 CM-1 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 WS-3 19L1 - 17 CM-2 E19L1 - 9 CM-2 E19L1 - 9 CM-2 E19L1 - 9 CM-2 E19L1 - 9 CM-2 E19L1 - 9 CM-2 E19L1 - 9 CM-2 E19L1 - 9CM-2 19L1 - 17 P2 E19H1 - 2 P2 E19H1 - 2 P2 E19H1 - 2 P2 E19H1 - 2 AX1 AX1 AX1 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. 5. CONTROL EXTERIOR LIGHTS VIA PHOTOCELL/ TIMECLOCK. 6. REFER TO LIGHT FIXTURE SCHEDULE ON E0-02. 7. COORDINATE EXIT LIGHTS WITH LIFE SAFETY DRAWINGS. 8. CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. LIGHTING NOTES: PROVIDE (1) "STW" FIXTURE TO STAIR LANDING. EACH CIRCUIT EXTENDS THE HEIGHT OF THE BUILDING. REFER TO E4 -04 AND E405 FOR STAIRWELL FIXTURE LAYOUT. PROVIDE "EPL" FIXTURES ON EVERY OTHER FLOOR FOR EVELVATOR SHART LIGHTING. CIRCUIT FIXTURES WITH #8 AWG WIRE. CONTROL FOR FIXTURES IS LOCATED IN THE FIRE COMMAND CENTER. KEYNOTES: (NOT ALL KEYNOTES APPLY TO EVERY DRAWING) 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:57:03 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE2−19 08.14.18ELECTRICAL REFLECTED CEILING PLAN − LEVELS 19−29 − TYPICAL RESIDENTIALLEVEL R2−R12401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/8" = 1'-0"E2-19 1 ELECTRICAL REFLECTED CEILING PLAN - LEVEL 19-29 - TYPICAL RESIDENTIAL UNIT LEVELS R2-R12 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION REFJJTV3 3 S FECTV JJ S 33TV 33S 33J J33JJ TVGD8 11 17 9 10 7 5 6 3 4 2 2 16 15 14 13 18 UCF UCF UH UB UB UF UB UB UH UE F-A 11 11 UB 1. ELECTRICAL AND COMMUNICATION OUTLETS (TELEPHONE, TV, AND INTERNET) SHALL BE INSTALLED AT SAME HEIGHTS. COORDINATE ELECTRICAL AND COMMUNICATION OUTLETS AND CABLING REQUIREMENTS BEFORE COMMENCING WORK. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF LIGHT SWITCHES AND ABOVE COUNTER RECEPTACLES TO ENSURE COMPLIANCE WITH ADA AND FAIR HOUSING ACT REQUIREMENTS. RECEPTACLES CAN BE PLACED IN FURRING WALLS NEXT TO COLUMNS. 3. RECEPTACLES INSTALLED IN RESIDENTIAL UNITS SHALL BE LISTED TAMPER RESISTANT. 4. ELECTRICAL DEVICES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN FIRE RATING UTILIZING PUTTY PACKS AND/OR LISTED INSERTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. METALLIC COVER PLATES ARE ANTICIPATED TO BE REQUIRED. 5. INSTALL BACK TO BACK DEVICES IN WALL IN SEPARATE STUD CAVITY. 6. REFRIGERATOR RECEPTACLES WITHIN 6' OF SINK SHALL BE GFCI AND THE FIRST RECEPTACLE IN THE CIRCUIT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RATED FLOOR-CEILING ASSEMBLY PENETRATION DETAILS. 8. REFER TO E6 SERIES DRAWING FOR APPLICABLE ELECTRICAL DETAILS. 9. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 10. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES. ACCESSIBLE UNITS ARE S-A, 1-B, 1-H. AND 2-A (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS NOT GREATER THAN 48" AFF. A TOGGLE SWITCH SHALL BE FIELD INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCH SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES. 11. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION). SENSORY-IMPAIRED UNITS ARE 1-H AND 2-A, S-A, AND 1-B (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE OUTSIDE OF ENTRY DOOR. TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVINGROOM. EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. POWER NOTES: APPLIANCE NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR CONDUCTOR SIZE, CONDUIT SIZE AND DISCONNECT SWITCH RATING. WHERE EQUIPMENT IS NOT ADDRESSED, REFER TO CONDUCTOR SCHEDULE. 2. CONTRACTOR SHALL COORDINATE APPLIANCE CONNECTION TYPE AND PROVIDE NECESSARY CONDUCTORS, CONDUIT, CORDS, PLUGS AND RECEPTACLES OF PROPER NEMA CONFIGURATION AS REQUIRED TO MAKE FINAL TERMINATIONS. 3. CORD AND PLUG CONNECTED APPLIANCES SHALL CONFORM TO NEC ARTICLE 422.16 AND NEC ARTICLE 422.33. 4. CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH LOCATED WITHIN SIGHT OF HVAC EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 440.14. 5. FOR PERMANENTLY CONNECTED APPLIANCES (EXCLUDING MOTOR DRIVEN EQUIPMENT), DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 6. PROVIDE JUNCTION BOX, CONDUCTORS AND CONDUIT AND MAKE FINAL CONNECTION TO WATER HEATER. WHERE INSTALLED IN PLENUM SPACES, PROVIDE FLEXIBLE METALLIC CONDUIT. DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 7. RECEPTACLES FOR REFRIGERATOR, WASHING MACHINE AND DRYER SHALL BE MOUNTED AT +36"AFF. PROVIDE NEMA 14-30R RECEPTACLE FOR DRYER. EXACT LOCATION FOR ALL APPLIANCE RECEPTACLES SHALL BE COORDINATED WITH ARCHITECT/OWNER AND INSTALLED EQUIPMENT. 8. KITCHEN APPLIANCE CIRCUIT WITH REFRIGERATOR RECEPTACLE SHALL HAVE RECEPTACLE AS FIRST OUTLET IN HOMERUN. 9. APARTMENT PLAN DRAWING SHOWS A SINGLE 220V OUTLET FOR STOVE. STOVE CONSISTS OF THREE COMPONENTS -GAS COOK TOP, OVEN, AND WARMING OVEN. PROVIDE 120V OUTLET (NOT SHOWN) ON APPLIANCE CIRCUIT FOR COOK TOP. PROVIDE 120V RECEPTACLE ON DEDICATED 15A CIRCUIT (NOT SHOWN) FOR WARMING OVEN. 1. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 2. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 3. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 4. RESIDENTIAL UNIT SMOKE DETECTORS ARE TO ANNUNCIATE IMMEDIATELY UPON DETECTION OF SMOKE WITHIN THE RESIDENCE. BUILDING EVACUATION ALARM SHALL NOT BE INITIATED. 5. PROVIDE ANNUNCIATION WITHIN RESIDENTIAL UNITS (85 dBA @ 10 FT AND 75 dBA AT PILLOW) THROUGHOUT THE RESIDENTIAL UNITS. 6. MULTIPLE SMOKE DETECTORS AND ANNUNCIATION DEVICES WITHIN RESIDENTIAL UNIT SHALL BE INTERLOCKED FOR COMMON INDICATION OF ALARM. 7. PROVIDE WIRING PER IBC 907.9.1.4 FOR VISUAL ANNUNCIATION FOR BEDROOMS AND SLEEPING UNITS IN STRUCTURES RATED AS R2. FIRE ALARM NOTES: 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. LIGHTING NOTES: FLOOR RECEPTACLE. COORDINATE LOCATION WITH ARCHITECT. CEILING FAN WITH LIGHTS/J-BOX. PROVIDE ONE SWITCH FOR FAN CONTROL AND SWITCH(ES) FOR LIGHT CONTROL. WATER HEATER DISCONNECT. HVAC SYSTEM DISCONNECT. WASHER RECEPTACLE. DRYER RECEPTACLE. DISHWASHER, PROVIDE GFCI BREAKER AT LOAD CENTER. REFRIGERATOR. RANGE. GARBAGE DISPOSAL. COORDINATE LOCATION OF DISPOSAL SWITCH WITH ARCHITECT. USB RECEPTACLE. PROTECT WITH UPSTREAM GFCI RECEPTACLE. SWITCH FOR UNDERCABINET LIGHTING. LOAD CENTER, COLOR PER ARCHITECT. COMBINATION SMOKE DETECTOR/CO DETECTOR. EXHAUST FAN. REFRIGERANT PIPING CHASE. MICROWAVE IT CABINET, COLOR PER ARCHITECT. KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 UA UB UB UCF UCF UF UE UB 16 3 4 13 2 2 5 6 15 14 18 8 9 17 10 7 11 1 10 13 4 3 15 658179 2 7 14 16 F-A 18 UH UAUBUBUB UCF UH UF UE UB 1 UA UB UB UCF UH UBUF8 9 17 10 7 6 5 13 18 UE 3 4 2 11 1 16 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:21:46 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−01 08.14.18ELECTRICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"E3-01 1 UNIT S-A PLAN SCALE: 1/4" = 1'-0"E3-01 2 UNIT S-B PLAN SCALE: 1/4" = 1'-0"E3-01 3 UNIT S-C PLAN SCALE: 1/4" = 1'-0"E3-01 4 UNIT S-D PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION TVTVJ J 3 3 S S 33TVTVJ JSS JTVSS J33J J JJ J TV TV 33 33 S S F-A UB UA UH UB UCFUCF UB UF 5 6 3 4 2 2 7 8 9 17 18 1 13 14 14 1 1. ELECTRICAL AND COMMUNICATION OUTLETS (TELEPHONE, TV, AND INTERNET) SHALL BE INSTALLED AT SAME HEIGHTS. COORDINATE ELECTRICAL AND COMMUNICATION OUTLETS AND CABLING REQUIREMENTS BEFORE COMMENCING WORK. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF LIGHT SWITCHES AND ABOVE COUNTER RECEPTACLES TO ENSURE COMPLIANCE WITH ADA AND FAIR HOUSING ACT REQUIREMENTS. RECEPTACLES CAN BE PLACED IN FURRING WALLS NEXT TO COLUMNS. 3. RECEPTACLES INSTALLED IN RESIDENTIAL UNITS SHALL BE LISTED TAMPER RESISTANT. 4. ELECTRICAL DEVICES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN FIRE RATING UTILIZING PUTTY PACKS AND/OR LISTED INSERTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. METALLIC COVER PLATES ARE ANTICIPATED TO BE REQUIRED. 5. INSTALL BACK TO BACK DEVICES IN WALL IN SEPARATE STUD CAVITY. 6. REFRIGERATOR RECEPTACLES WITHIN 6' OF SINK SHALL BE GFCI AND THE FIRST RECEPTACLE IN THE CIRCUIT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RATED FLOOR-CEILING ASSEMBLY PENETRATION DETAILS. 8. REFER TO E6 SERIES DRAWING FOR APPLICABLE ELECTRICAL DETAILS. 9. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 10. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES. ACCESSIBLE UNITS ARE S-A, 1-B, 1-H. AND 2-A (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS NOT GREATER THAN 48" AFF. A TOGGLE SWITCH SHALL BE FIELD INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCH SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES. 11. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION). SENSORY-IMPAIRED UNITS ARE 1-H AND 2-A, S-A, AND 1-B (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE OUTSIDE OF ENTRY DOOR. TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVINGROOM. EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. POWER NOTES: APPLIANCE NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR CONDUCTOR SIZE, CONDUIT SIZE AND DISCONNECT SWITCH RATING. WHERE EQUIPMENT IS NOT ADDRESSED, REFER TO CONDUCTOR SCHEDULE. 2. CONTRACTOR SHALL COORDINATE APPLIANCE CONNECTION TYPE AND PROVIDE NECESSARY CONDUCTORS, CONDUIT, CORDS, PLUGS AND RECEPTACLES OF PROPER NEMA CONFIGURATION AS REQUIRED TO MAKE FINAL TERMINATIONS. 3. CORD AND PLUG CONNECTED APPLIANCES SHALL CONFORM TO NEC ARTICLE 422.16 AND NEC ARTICLE 422.33. 4. CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH LOCATED WITHIN SIGHT OF HVAC EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 440.14. 5. FOR PERMANENTLY CONNECTED APPLIANCES (EXCLUDING MOTOR DRIVEN EQUIPMENT), DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 6. PROVIDE JUNCTION BOX, CONDUCTORS AND CONDUIT AND MAKE FINAL CONNECTION TO WATER HEATER. WHERE INSTALLED IN PLENUM SPACES, PROVIDE FLEXIBLE METALLIC CONDUIT. DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 7. RECEPTACLES FOR REFRIGERATOR, WASHING MACHINE AND DRYER SHALL BE MOUNTED AT +36"AFF. PROVIDE NEMA 14-30R RECEPTACLE FOR DRYER. EXACT LOCATION FOR ALL APPLIANCE RECEPTACLES SHALL BE COORDINATED WITH ARCHITECT/OWNER AND INSTALLED EQUIPMENT. 8. KITCHEN APPLIANCE CIRCUIT WITH REFRIGERATOR RECEPTACLE SHALL HAVE RECEPTACLE AS FIRST OUTLET IN HOMERUN. 9. APARTMENT PLAN DRAWING SHOWS A SINGLE 220V OUTLET FOR STOVE. STOVE CONSISTS OF THREE COMPONENTS -GAS COOK TOP, OVEN, AND WARMING OVEN. PROVIDE 120V OUTLET (NOT SHOWN) ON APPLIANCE CIRCUIT FOR COOK TOP. PROVIDE 120V RECEPTACLE ON DEDICATED 15A CIRCUIT (NOT SHOWN) FOR WARMING OVEN. 1. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 2. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 3. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 4. RESIDENTIAL UNIT SMOKE DETECTORS ARE TO ANNUNCIATE IMMEDIATELY UPON DETECTION OF SMOKE WITHIN THE RESIDENCE. BUILDING EVACUATION ALARM SHALL NOT BE INITIATED. 5. PROVIDE ANNUNCIATION WITHIN RESIDENTIAL UNITS (85 dBA @ 10 FT AND 75 dBA AT PILLOW) THROUGHOUT THE RESIDENTIAL UNITS. 6. MULTIPLE SMOKE DETECTORS AND ANNUNCIATION DEVICES WITHIN RESIDENTIAL UNIT SHALL BE INTERLOCKED FOR COMMON INDICATION OF ALARM. 7. PROVIDE WIRING PER IBC 907.9.1.4 FOR VISUAL ANNUNCIATION FOR BEDROOMS AND SLEEPING UNITS IN STRUCTURES RATED AS R2. FIRE ALARM NOTES: 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. LIGHTING NOTES: FLOOR RECEPTACLE. COORDINATE LOCATION WITH ARCHITECT. CEILING FAN WITH LIGHTS/J-BOX. PROVIDE ONE SWITCH FOR FAN CONTROL AND SWITCH(ES) FOR LIGHT CONTROL. WATER HEATER DISCONNECT. HVAC SYSTEM DISCONNECT. WASHER RECEPTACLE. DRYER RECEPTACLE. DISHWASHER, PROVIDE GFCI BREAKER AT LOAD CENTER. REFRIGERATOR. RANGE. GARBAGE DISPOSAL. COORDINATE LOCATION OF DISPOSAL SWITCH WITH ARCHITECT. USB RECEPTACLE. PROTECT WITH UPSTREAM GFCI RECEPTACLE. SWITCH FOR UNDERCABINET LIGHTING. LOAD CENTER, COLOR PER ARCHITECT. COMBINATION SMOKE DETECTOR/CO DETECTOR. EXHAUST FAN. REFRIGERANT PIPING CHASE. MICROWAVE IT CABINET, COLOR PER ARCHITECT. KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 15 3 4 5 6 UA UB UB UB UC UC UF UH UB UBUE 8 17 9 11 10 2 2 7 13 14 14 UCF UCF 18 11 16 F-A UC UC UA UB UH UB UB UF UCF UCF 16 6 7 3 4 17 9 107 11 1414 13 18 UE 8 15 UB UB UB 1 1 1 1 F-A UCF UB UA UE UBUB UBUB UH UCF 3 4710917 18 8 2 2 15 14 14 6 5 UF 1 F-A c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:05 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−02 08.14.18ELECTRICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"E3-02 1 UNIT 1-A PLAN SCALE: 1/4" = 1'-0"E3-02 2 UNIT 1-B PLAN SCALE: 1/4" = 1'-0"E3-02 3 UNIT 1-C PLAN SCALE: 1/4" = 1'-0"E3-02 4 UNIT 1-D PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FECTV TVJREF S S 33J 33 3 3 33 JJ 33S SJJ333 S S 3J J 3 3333 S S J 31. ELECTRICAL AND COMMUNICATION OUTLETS (TELEPHONE, TV, AND INTERNET) SHALL BE INSTALLED AT SAME HEIGHTS. COORDINATE ELECTRICAL AND COMMUNICATION OUTLETS AND CABLING REQUIREMENTS BEFORE COMMENCING WORK. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF LIGHT SWITCHES AND ABOVE COUNTER RECEPTACLES TO ENSURE COMPLIANCE WITH ADA AND FAIR HOUSING ACT REQUIREMENTS. RECEPTACLES CAN BE PLACED IN FURRING WALLS NEXT TO COLUMNS. 3. RECEPTACLES INSTALLED IN RESIDENTIAL UNITS SHALL BE LISTED TAMPER RESISTANT. 4. ELECTRICAL DEVICES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN FIRE RATING UTILIZING PUTTY PACKS AND/OR LISTED INSERTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. METALLIC COVER PLATES ARE ANTICIPATED TO BE REQUIRED. 5. INSTALL BACK TO BACK DEVICES IN WALL IN SEPARATE STUD CAVITY. 6. REFRIGERATOR RECEPTACLES WITHIN 6' OF SINK SHALL BE GFCI AND THE FIRST RECEPTACLE IN THE CIRCUIT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RATED FLOOR-CEILING ASSEMBLY PENETRATION DETAILS. 8. REFER TO E6 SERIES DRAWING FOR APPLICABLE ELECTRICAL DETAILS. 9. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 10. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES. ACCESSIBLE UNITS ARE S-A, 1-B, 1-H. AND 2-A (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS NOT GREATER THAN 48" AFF. A TOGGLE SWITCH SHALL BE FIELD INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCH SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES. 11. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION). SENSORY-IMPAIRED UNITS ARE 1-H AND 2-A, S-A, AND 1-B (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE OUTSIDE OF ENTRY DOOR. TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVINGROOM. EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. POWER NOTES: APPLIANCE NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR CONDUCTOR SIZE, CONDUIT SIZE AND DISCONNECT SWITCH RATING. WHERE EQUIPMENT IS NOT ADDRESSED, REFER TO CONDUCTOR SCHEDULE. 2. CONTRACTOR SHALL COORDINATE APPLIANCE CONNECTION TYPE AND PROVIDE NECESSARY CONDUCTORS, CONDUIT, CORDS, PLUGS AND RECEPTACLES OF PROPER NEMA CONFIGURATION AS REQUIRED TO MAKE FINAL TERMINATIONS. 3. CORD AND PLUG CONNECTED APPLIANCES SHALL CONFORM TO NEC ARTICLE 422.16 AND NEC ARTICLE 422.33. 4. CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH LOCATED WITHIN SIGHT OF HVAC EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 440.14. 5. FOR PERMANENTLY CONNECTED APPLIANCES (EXCLUDING MOTOR DRIVEN EQUIPMENT), DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 6. PROVIDE JUNCTION BOX, CONDUCTORS AND CONDUIT AND MAKE FINAL CONNECTION TO WATER HEATER. WHERE INSTALLED IN PLENUM SPACES, PROVIDE FLEXIBLE METALLIC CONDUIT. DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 7. RECEPTACLES FOR REFRIGERATOR, WASHING MACHINE AND DRYER SHALL BE MOUNTED AT +36"AFF. PROVIDE NEMA 14-30R RECEPTACLE FOR DRYER. EXACT LOCATION FOR ALL APPLIANCE RECEPTACLES SHALL BE COORDINATED WITH ARCHITECT/OWNER AND INSTALLED EQUIPMENT. 8. KITCHEN APPLIANCE CIRCUIT WITH REFRIGERATOR RECEPTACLE SHALL HAVE RECEPTACLE AS FIRST OUTLET IN HOMERUN. 9. APARTMENT PLAN DRAWING SHOWS A SINGLE 220V OUTLET FOR STOVE. STOVE CONSISTS OF THREE COMPONENTS -GAS COOK TOP, OVEN, AND WARMING OVEN. PROVIDE 120V OUTLET (NOT SHOWN) ON APPLIANCE CIRCUIT FOR COOK TOP. PROVIDE 120V RECEPTACLE ON DEDICATED 15A CIRCUIT (NOT SHOWN) FOR WARMING OVEN. 1. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 2. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 3. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 4. RESIDENTIAL UNIT SMOKE DETECTORS ARE TO ANNUNCIATE IMMEDIATELY UPON DETECTION OF SMOKE WITHIN THE RESIDENCE. BUILDING EVACUATION ALARM SHALL NOT BE INITIATED. 5. PROVIDE ANNUNCIATION WITHIN RESIDENTIAL UNITS (85 dBA @ 10 FT AND 75 dBA AT PILLOW) THROUGHOUT THE RESIDENTIAL UNITS. 6. MULTIPLE SMOKE DETECTORS AND ANNUNCIATION DEVICES WITHIN RESIDENTIAL UNIT SHALL BE INTERLOCKED FOR COMMON INDICATION OF ALARM. 7. PROVIDE WIRING PER IBC 907.9.1.4 FOR VISUAL ANNUNCIATION FOR BEDROOMS AND SLEEPING UNITS IN STRUCTURES RATED AS R2. FIRE ALARM NOTES: 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. LIGHTING NOTES: FLOOR RECEPTACLE. COORDINATE LOCATION WITH ARCHITECT. CEILING FAN WITH LIGHTS/J-BOX. PROVIDE ONE SWITCH FOR FAN CONTROL AND SWITCH(ES) FOR LIGHT CONTROL. WATER HEATER DISCONNECT. HVAC SYSTEM DISCONNECT. WASHER RECEPTACLE. DRYER RECEPTACLE. DISHWASHER, PROVIDE GFCI BREAKER AT LOAD CENTER. REFRIGERATOR. RANGE. GARBAGE DISPOSAL. COORDINATE LOCATION OF DISPOSAL SWITCH WITH ARCHITECT. USB RECEPTACLE. PROTECT WITH UPSTREAM GFCI RECEPTACLE. SWITCH FOR UNDERCABINET LIGHTING. LOAD CENTER, COLOR PER ARCHITECT. COMBINATION SMOKE DETECTOR/CO DETECTOR. EXHAUST FAN. REFRIGERANT PIPING CHASE. MICROWAVE IT CABINET, COLOR PER ARCHITECT. KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 3 4 16 6 5 9 17 10 13 14 14 18 UA UB UB UB UC UC 7 UH UF UB UB UE UCF UCF UB UB UBUB F-A 11 11 1 1 34 16 8 9 17 710 5 6 14 14 15 11 11 13 UA UBUB UCUC UCFUCF UF UH UB 18 11 3 4 16 8 17 7 10 9 15 13 14 14 6 5 UB UB UB UAUB UF UCF UE UCF 18 1 1 F-A 568917 10 3 4 16 15 13 14 14 7 UFUB UB UB UE UE UCF UCF UC UC UB UB UA UH 1811 1 1 1 1 1 1 F-A c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:20 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−03 08.14.18ELECTRICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"E3-03 1 UNIT 1-E PLAN SCALE: 1/4" = 1'-0"E3-03 2 UNIT 1-F PLAN SCALE: 1/4" = 1'-0"E3-03 3 UNIT 1-G PLAN SCALE: 1/4" = 1'-0"E3-03 4 UNIT 1-H PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION REFJJJ J 3333 3 3TVSS FECS S TVTVJJ3 3333J 1. ELECTRICAL AND COMMUNICATION OUTLETS (TELEPHONE, TV, AND INTERNET) SHALL BE INSTALLED AT SAME HEIGHTS. COORDINATE ELECTRICAL AND COMMUNICATION OUTLETS AND CABLING REQUIREMENTS BEFORE COMMENCING WORK. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF LIGHT SWITCHES AND ABOVE COUNTER RECEPTACLES TO ENSURE COMPLIANCE WITH ADA AND FAIR HOUSING ACT REQUIREMENTS. RECEPTACLES CAN BE PLACED IN FURRING WALLS NEXT TO COLUMNS. 3. RECEPTACLES INSTALLED IN RESIDENTIAL UNITS SHALL BE LISTED TAMPER RESISTANT. 4. ELECTRICAL DEVICES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN FIRE RATING UTILIZING PUTTY PACKS AND/OR LISTED INSERTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. METALLIC COVER PLATES ARE ANTICIPATED TO BE REQUIRED. 5. INSTALL BACK TO BACK DEVICES IN WALL IN SEPARATE STUD CAVITY. 6. REFRIGERATOR RECEPTACLES WITHIN 6' OF SINK SHALL BE GFCI AND THE FIRST RECEPTACLE IN THE CIRCUIT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RATED FLOOR-CEILING ASSEMBLY PENETRATION DETAILS. 8. REFER TO E6 SERIES DRAWING FOR APPLICABLE ELECTRICAL DETAILS. 9. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 10. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES. ACCESSIBLE UNITS ARE S-A, 1-B, 1-H. AND 2-A (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS NOT GREATER THAN 48" AFF. A TOGGLE SWITCH SHALL BE FIELD INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCH SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES. 11. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION). SENSORY-IMPAIRED UNITS ARE 1-H AND 2-A, S-A, AND 1-B (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE OUTSIDE OF ENTRY DOOR. TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVINGROOM. EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. POWER NOTES: APPLIANCE NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR CONDUCTOR SIZE, CONDUIT SIZE AND DISCONNECT SWITCH RATING. WHERE EQUIPMENT IS NOT ADDRESSED, REFER TO CONDUCTOR SCHEDULE. 2. CONTRACTOR SHALL COORDINATE APPLIANCE CONNECTION TYPE AND PROVIDE NECESSARY CONDUCTORS, CONDUIT, CORDS, PLUGS AND RECEPTACLES OF PROPER NEMA CONFIGURATION AS REQUIRED TO MAKE FINAL TERMINATIONS. 3. CORD AND PLUG CONNECTED APPLIANCES SHALL CONFORM TO NEC ARTICLE 422.16 AND NEC ARTICLE 422.33. 4. CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH LOCATED WITHIN SIGHT OF HVAC EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 440.14. 5. FOR PERMANENTLY CONNECTED APPLIANCES (EXCLUDING MOTOR DRIVEN EQUIPMENT), DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 6. PROVIDE JUNCTION BOX, CONDUCTORS AND CONDUIT AND MAKE FINAL CONNECTION TO WATER HEATER. WHERE INSTALLED IN PLENUM SPACES, PROVIDE FLEXIBLE METALLIC CONDUIT. DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 7. RECEPTACLES FOR REFRIGERATOR, WASHING MACHINE AND DRYER SHALL BE MOUNTED AT +36"AFF. PROVIDE NEMA 14-30R RECEPTACLE FOR DRYER. EXACT LOCATION FOR ALL APPLIANCE RECEPTACLES SHALL BE COORDINATED WITH ARCHITECT/OWNER AND INSTALLED EQUIPMENT. 8. KITCHEN APPLIANCE CIRCUIT WITH REFRIGERATOR RECEPTACLE SHALL HAVE RECEPTACLE AS FIRST OUTLET IN HOMERUN. 9. APARTMENT PLAN DRAWING SHOWS A SINGLE 220V OUTLET FOR STOVE. STOVE CONSISTS OF THREE COMPONENTS -GAS COOK TOP, OVEN, AND WARMING OVEN. PROVIDE 120V OUTLET (NOT SHOWN) ON APPLIANCE CIRCUIT FOR COOK TOP. PROVIDE 120V RECEPTACLE ON DEDICATED 15A CIRCUIT (NOT SHOWN) FOR WARMING OVEN. 1. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 2. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 3. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 4. RESIDENTIAL UNIT SMOKE DETECTORS ARE TO ANNUNCIATE IMMEDIATELY UPON DETECTION OF SMOKE WITHIN THE RESIDENCE. BUILDING EVACUATION ALARM SHALL NOT BE INITIATED. 5. PROVIDE ANNUNCIATION WITHIN RESIDENTIAL UNITS (85 dBA @ 10 FT AND 75 dBA AT PILLOW) THROUGHOUT THE RESIDENTIAL UNITS. 6. MULTIPLE SMOKE DETECTORS AND ANNUNCIATION DEVICES WITHIN RESIDENTIAL UNIT SHALL BE INTERLOCKED FOR COMMON INDICATION OF ALARM. 7. PROVIDE WIRING PER IBC 907.9.1.4 FOR VISUAL ANNUNCIATION FOR BEDROOMS AND SLEEPING UNITS IN STRUCTURES RATED AS R2. FIRE ALARM NOTES: 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. LIGHTING NOTES: FLOOR RECEPTACLE. COORDINATE LOCATION WITH ARCHITECT. CEILING FAN WITH LIGHTS/J-BOX. PROVIDE ONE SWITCH FOR FAN CONTROL AND SWITCH(ES) FOR LIGHT CONTROL. WATER HEATER DISCONNECT. HVAC SYSTEM DISCONNECT. WASHER RECEPTACLE. DRYER RECEPTACLE. DISHWASHER, PROVIDE GFCI BREAKER AT LOAD CENTER. REFRIGERATOR. RANGE. GARBAGE DISPOSAL. COORDINATE LOCATION OF DISPOSAL SWITCH WITH ARCHITECT. USB RECEPTACLE. PROTECT WITH UPSTREAM GFCI RECEPTACLE. SWITCH FOR UNDERCABINET LIGHTING. LOAD CENTER, COLOR PER ARCHITECT. COMBINATION SMOKE DETECTOR/CO DETECTOR. EXHAUST FAN. REFRIGERANT PIPING CHASE. MICROWAVE IT CABINET, COLOR PER ARCHITECT. KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 5 68917 7 3 4 14 14 15 UA UB UBUB UC UC UH UB UB UF UCF 2 2 UCF 11 18 UH UE 1 1 1 1 13 F-A 1 2 2 7 10 17 9 8 5 6 3 4 16 13 15 14 14 18 UA UB UB UB UCF UB UE UF UCF UB 1 F-A c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:32 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−04 08.14.18ELECTRICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"E3-04 1 UNIT 1-J PLAN SCALE: 1/4" = 1'-0"E3-04 2 UNIT 1-K PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FEC TV S S S S3 3333333 JJ S STVTVTVJJ33 3 3 33 3 3 3 33 S 3J JTVJJTVTVTV3 333 33 3333 33 SS S S 1. ELECTRICAL AND COMMUNICATION OUTLETS (TELEPHONE, TV, AND INTERNET) SHALL BE INSTALLED AT SAME HEIGHTS. COORDINATE ELECTRICAL AND COMMUNICATION OUTLETS AND CABLING REQUIREMENTS BEFORE COMMENCING WORK. 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF LIGHT SWITCHES AND ABOVE COUNTER RECEPTACLES TO ENSURE COMPLIANCE WITH ADA AND FAIR HOUSING ACT REQUIREMENTS. RECEPTACLES CAN BE PLACED IN FURRING WALLS NEXT TO COLUMNS. 3. RECEPTACLES INSTALLED IN RESIDENTIAL UNITS SHALL BE LISTED TAMPER RESISTANT. 4. ELECTRICAL DEVICES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN FIRE RATING UTILIZING PUTTY PACKS AND/OR LISTED INSERTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. METALLIC COVER PLATES ARE ANTICIPATED TO BE REQUIRED. 5. INSTALL BACK TO BACK DEVICES IN WALL IN SEPARATE STUD CAVITY. 6. REFRIGERATOR RECEPTACLES WITHIN 6' OF SINK SHALL BE GFCI AND THE FIRST RECEPTACLE IN THE CIRCUIT. 7. REFER TO ARCHITECTURAL DRAWINGS FOR RATED FLOOR-CEILING ASSEMBLY PENETRATION DETAILS. 8. REFER TO E6 SERIES DRAWING FOR APPLICABLE ELECTRICAL DETAILS. 9. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 10. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES. ACCESSIBLE UNITS ARE S-A, 1-B, 1-H. AND 2-A (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS NOT GREATER THAN 48" AFF. A TOGGLE SWITCH SHALL BE FIELD INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCH SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES. 11. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION). SENSORY-IMPAIRED UNITS ARE 1-H AND 2-A, S-A, AND 1-B (REFER TO ARCHITECTURAL DRAWINGS FOR UNIT LOCATIONS). FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE OUTSIDE OF ENTRY DOOR. TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVINGROOM. EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. POWER NOTES: APPLIANCE NOTES: 1. REFER TO EQUIPMENT SCHEDULE FOR CONDUCTOR SIZE, CONDUIT SIZE AND DISCONNECT SWITCH RATING. WHERE EQUIPMENT IS NOT ADDRESSED, REFER TO CONDUCTOR SCHEDULE. 2. CONTRACTOR SHALL COORDINATE APPLIANCE CONNECTION TYPE AND PROVIDE NECESSARY CONDUCTORS, CONDUIT, CORDS, PLUGS AND RECEPTACLES OF PROPER NEMA CONFIGURATION AS REQUIRED TO MAKE FINAL TERMINATIONS. 3. CORD AND PLUG CONNECTED APPLIANCES SHALL CONFORM TO NEC ARTICLE 422.16 AND NEC ARTICLE 422.33. 4. CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH LOCATED WITHIN SIGHT OF HVAC EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 440.14. 5. FOR PERMANENTLY CONNECTED APPLIANCES (EXCLUDING MOTOR DRIVEN EQUIPMENT), DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 6. PROVIDE JUNCTION BOX, CONDUCTORS AND CONDUIT AND MAKE FINAL CONNECTION TO WATER HEATER. WHERE INSTALLED IN PLENUM SPACES, PROVIDE FLEXIBLE METALLIC CONDUIT. DISCONNECTING MEANS SHALL BE PROVIDED BY A LOCKABLE BREAKER IN THE PANEL IN ACCORDANCE WITH NEC ARTICLE 422.31(B). 7. RECEPTACLES FOR REFRIGERATOR, WASHING MACHINE AND DRYER SHALL BE MOUNTED AT +36"AFF. PROVIDE NEMA 14-30R RECEPTACLE FOR DRYER. EXACT LOCATION FOR ALL APPLIANCE RECEPTACLES SHALL BE COORDINATED WITH ARCHITECT/OWNER AND INSTALLED EQUIPMENT. 8. KITCHEN APPLIANCE CIRCUIT WITH REFRIGERATOR RECEPTACLE SHALL HAVE RECEPTACLE AS FIRST OUTLET IN HOMERUN. 9. APARTMENT PLAN DRAWING SHOWS A SINGLE 220V OUTLET FOR STOVE. STOVE CONSISTS OF THREE COMPONENTS -GAS COOK TOP, OVEN, AND WARMING OVEN. PROVIDE 120V OUTLET (NOT SHOWN) ON APPLIANCE CIRCUIT FOR COOK TOP. PROVIDE 120V RECEPTACLE ON DEDICATED 15A CIRCUIT (NOT SHOWN) FOR WARMING OVEN. 1. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 2. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 3. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 4. RESIDENTIAL UNIT SMOKE DETECTORS ARE TO ANNUNCIATE IMMEDIATELY UPON DETECTION OF SMOKE WITHIN THE RESIDENCE. BUILDING EVACUATION ALARM SHALL NOT BE INITIATED. 5. PROVIDE ANNUNCIATION WITHIN RESIDENTIAL UNITS (85 dBA @ 10 FT AND 75 dBA AT PILLOW) THROUGHOUT THE RESIDENTIAL UNITS. 6. MULTIPLE SMOKE DETECTORS AND ANNUNCIATION DEVICES WITHIN RESIDENTIAL UNIT SHALL BE INTERLOCKED FOR COMMON INDICATION OF ALARM. 7. PROVIDE WIRING PER IBC 907.9.1.4 FOR VISUAL ANNUNCIATION FOR BEDROOMS AND SLEEPING UNITS IN STRUCTURES RATED AS R2. FIRE ALARM NOTES: 1. EXIT AND EGRESS LIGHTING FIXTURES SHALL BE WIRED TO NEAREST LIFE SAFETY CIRCUIT SERVING SAME AREA AND AHEAD OF SWITCHING. 2. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT ARRANGEMENT AND LOCATION OF FIXTURES AND OTHER REQUIREMENTS. 3. LIGHTING CONTROLLED BY TIME CLOCK OR OTHER AUTOMATED CONTROL SHALL HAVE A LOCAL OVERRIDE SWITCH. 4. AT FINAL ACCEPTANCE BY OWNER CLEAN FIXTURES AND LENS, REMOVE ANY PROTECTIVE COVERING, REPLACE FAILED LAMPS OR BALLAST, AND PROVE BATTERY BACKUP SYSTEMS ARE FUNCTIONAL. LIGHTING NOTES: FLOOR RECEPTACLE. COORDINATE LOCATION WITH ARCHITECT. CEILING FAN WITH LIGHTS/J-BOX. PROVIDE ONE SWITCH FOR FAN CONTROL AND SWITCH(ES) FOR LIGHT CONTROL. WATER HEATER DISCONNECT. HVAC SYSTEM DISCONNECT. WASHER RECEPTACLE. DRYER RECEPTACLE. DISHWASHER, PROVIDE GFCI BREAKER AT LOAD CENTER. REFRIGERATOR. RANGE. GARBAGE DISPOSAL. COORDINATE LOCATION OF DISPOSAL SWITCH WITH ARCHITECT. USB RECEPTACLE. PROTECT WITH UPSTREAM GFCI RECEPTACLE. SWITCH FOR UNDERCABINET LIGHTING. LOAD CENTER, COLOR PER ARCHITECT. COMBINATION SMOKE DETECTOR/CO DETECTOR. EXHAUST FAN. REFRIGERANT PIPING CHASE. MICROWAVE IT CABINET, COLOR PER ARCHITECT. KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 43 16 13 15 2 2 2 14 14 14 14 15 6 5 11 710 9 17 UB UB UB UBUCUC UA UCF UF UE UH UF UB UB UE UCF UCF 18 UH 11 1 F-A F-A 8 UCF UCF F-A 14 14 9 10 11 17 8 5 6 14 13 14 16 3 4 15 7 15 7 2 2 2 11 18 UB UB UC UC UC UH UB UF UA UB UCF UB UH UF UE UE 1 1 1 1 F-A 1 1414 9 17 10 7 8 15 13 14 14 2 15 5 6 3 4 16 11 18 UCF UE UB UF UCF UCF UF UB UH UB UB UC UC UA UB UB UH 2 2 11 1 1 11 F-A 1 F-A c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:44 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−05 08.14.18ELECTRICAL UNIT PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/4" = 1'-0"E3-05 1 UNIT 2-A PLAN SCALE: 1/4" = 1'-0"E3-05 2 UNIT 2-B PLAN SCALE: 1/4" = 1'-0"E3-05 3 UNIT 2-C PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION FEC FEFECLEVEL 1 − OFFICE LOBBY 711’ − 0" LEVEL 2 − P2 735’ − 9" 4 LEVEL 1.5 − RES. LOBBY 715’ − 3" 3.94.955.3 HOUSE RISER RESIDENTIAL RISER R1 RESIDENTIAL RISER R2 MSB-HOUSE R1 R21DP 1L1T-1L1 1H1 ATS-1 ATS-2 ATS-3 T-EL1 E1L11LR T-1LLR 1LLRZ1H1E1H1 POWER NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR EXACT PLACEMENT OF OUTLETS, DEVICES, AND OTHER REQUIREMENTS. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. REFER TO AUDIO VISUAL, SECURITY, INFORMATION TECHNOLOGY AND MATV DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 5. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT. DO NOT SHARE NEUTRALS. 6. 120V BRANCH CIRCUIT HOMERUNS ARE SHOWN AS INDIVIDUAL CIRCUITS. IN GENERAL, UNLESS PROHIBITED ELSEWHERE IN CONTRACT DOCUMENTS, CONTRACTOR MAY COMBINE 120V HOMERUNS AND SHARE NEUTRALS PROVIDED NEC REQUIREMENTS ARE MET FOR FILL AND NUMBER OF CONDUCTOR DERATING. 7.CIRCUITS 75' OR GREATER USE #10 AWG OR NEXT LARGER SIZE. 8.FIRE SMOKE DAMPERS(FSD) ARE TO BE FAIL CLOSED. CONNECT TO NEARBY 120V LIGHTING CIRCUIT. IF A 120V LIGHTING CIRCUIT IS NOT AVAILABLE, CONNECTO TO NEARBY RECEPTACLE CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ALL FSD LOCATIONS. 9.REFER TO E5 SERIES DRAWINGS FOR ELECTRICAL SCHEDULES. 10.REFER TO E6 SERIES DRAWINGS FOR ELECTRICAL DETAILS. 11.REFER TO TSYS DRAWINGS FOR LOW VOLTAGE CONDUIT REQUIREMENTS. 1. WALL MOUNTED FIRE ALARM DEVICES SHALL BE INSTALLED WITH CONDUIT INTO ACCESSIBLE CEILING SPACE. 2. FINAL FIRE ALARM INSTALLATION SHALL BE CERTIFIED BY MANUFACTURER'S FIELD REPRESENTATIVE. 3. MAINTAIN SMOKE AND HEAT DETECTORS' DUST COVERS TO FINAL ACCEPTANCE OR FOR TESTING. 4. FIRE ALARM SYSTEM AND WORK SHALL BE IN COMPLIANCE WITH NFPA 72 AND GOVERNING LOCAL CODES AND REGULATIONS. 5. FIRE ALARM ANNUNCIATION DEVICES MOUNTED IN UNCONDITIONED SPACES SHALL BE WEATHERPROOF. FIRE ALARM NOTES: c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:52 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE3−10 08.14.18ELECTRICAL ENLARGED PLANS401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 N SCALE: 1/4" = 1'-0"E3-10 1 BUSDUCT N SCALE: 1/4" = 1'-0"E3-10 2 ELECTRICAL ROOM ENLARGED PLAN Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION SYMBOL(S)DESCRIPTION NOTESMOUNT HEIGHT S H S F 3#12, #10G 1/2" THREE PHASE TRANSFORMER CONDUCTOR SCHEDULE (ALUMINUM*) 3 CONDUCTORS & GROUNDKVA 6 20A/3P 4#12, #8G 4 CONDUCTORS & GROUNDOCPD 20A/3P 480V PRIMARY 3PH, 3W 208V/120V SECONDARY 3PH, 4W 9 20A/3P 4#10, #8G30A/3P1/2" 3#10, #8G15 30A/3P 4#6, #8G50A/3P1/2" 1/2" 1" 3/4" 3#6, #8G30 50A/3P 100A/3P3/4"4#1, #6G 1-1/2" 45 80A/3P 150A/3P3#2, #6G 2"4#3/0, #4G 75 125A/3P 250A/3P1-1/2"3#2/0, #4G 3"4#350, #1/0G 112.5 200A/3P 400A/3P2-1/2"3#250KCMIL, #2G 4"4#700KCMIL, #3/0G 150 500A/3P250A/3P 3#350KCMIL, #2G (2) 3"(2 SETS) 4#350KCMIL, #3/0G 225 700A/3P400A/3P (2 SETS) 3#250KCMIL, #2G (2) 2"(2) 4"(2 SETS) 4#700KCMIL, #4/0G 300 1000A/3P500A/3P (3 SETS) 4#600KCMIL, #250G 500 1600A/3P1000A/3P (4) 3"(3 SETS) 3#600KCMIL, #1G (5) 4"(5 SETS) 4#600KCMIL, #400G 3#12, #10G 2-1/2" GROUNDING ELECTRODE #6 #4 #1/0 #3/0 #3/0 #4/0 #250 #250 1-1/4" (2 SETS) 3#350KCMIL, #2G #6 #6 #6 TAG T#P TAG T#S MAX OCPD MAX * * * * * * * * * NOTE: *COPPER CONDUCTORS TO BE USED FOR ALL CONDUCTORS LESS THAN 1/0 AWG. CONDUIT CONDUIT T6P T9P T15P T30P T45P (2) 2-1/2"(3) 3-1/2" T75P T112P T150P T225P T300P T500P T6S T9S T15S T30S T75S T112S T150S T225S T300S T500S T45S SYMBOLS ARE SHOWN FOR REFERENCE ONLY AND MAY OR MAY NOT BE USED ELSEWHERE IN CONSTRUCTION DOCUMENTS. SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR PULL STATION HORN OR SPEAKER HORN OR SPEAKER WITH STROBE STROBE DOOR HOLD REMOTE RESET FACP FIRE ALARM CONTROL PANEL TAMPER SWITCH WATER FLOW SWITCH AR AM ADDRESSABLE INPUT MODULE ADDRESSABLE RELAY MODULE FAAP FIRE ALARM ANNUNCIATION PANEL R CONTINUATION OF CIRCUIT WITH DEVICES OMITTED FIRE PHONEF FIRE ALARM RISER LEGEND TAG 3 CONDUCTORS & GROUND 4 CONDUCTORS & GROUNDTAGCONDUIT CONDUIT THREE PHASE FEEDER SCHEDULE ALUMINUM CONDUCTORS, 75C RATING W/ GROUND WIRE 1/2" 1/2" 3/4" 1" 1-1/4" 1-1/4" 1/2" 1/2" 3/4" 1-1/4" 3#12, #12G 4#12, #12G 3#4, #8G 3#10, #10G 4#10, #10G 4#8, #10G 4#6, #8G 4#4, #8G 4#3, #6G 3#8, #10G 3#6, #8G 30N 40N 3#3, #6G 65N 85N 100N 3" 20N 2" 3" 3" 4" (2 SETS) 3#300KCMIL, #1/0G 30 20 40 65 85 100 20A 30A (2 SETS) 4#300KCMIL, #1/0G 50A (2 SETS) 4#350KCMIL, #1/0G (2 SETS) 4#400KCMIL, #2/0G 70A (2 SETS) 4#500KCMIL, #3/0G 90A 110A 1" 1-1/4" 2"3#1/0, #4G 3#2/0, #4G 3#3/0, #4G 3#4/0, #4G 3#250KCMIL, #2G 3#300KCMIL, #2G 3#350KCMIL, #2G 3#600KCMIL, #1G 3#400KCMIL, #2G 3"3#500KCMIL, #1G 4" 3#700KCMIL, #1G 3#750KCMIL, #1G 2" 2"2" 2" 3"2" 3" 3" 3" 3" 4" 4" (2 SETS) 3#250KCMIL, #1/0G (2 SETS) 3#350KCMIL, #1/0G (2 SETS) 3#500KCMIL, #3/0G (2) 3" (2 SETS) 3#700KCMIL, #3/0G (2 SETS) 3#400KCMIL, #2/0G (2 SETS) 3#750KCMIL, #3/0G (2 SETS) 3#600KCMIL, #3/0G (2) 4" (2) 3" (2) 3" (2) 3" (2) 3" (2) 3" (2) 4" (2) 4" 4#2/0, #4G 4#1/0, #4G 4#3/0, #4G 4#4/0, #4G 4#250KCMIL, #2G 4#350KCMIL, #2G 4#300KCMIL, #2G 4#600KCMIL, #1G 4#400KCMIL, #2G 4#500KCMIL, #1G 4#700KCMIL, #1G (2 SETS) 4#250KCMIL, #1/0G 4#750KCMIL, #1G (2 SETS) 4#700KCMIL, #3/0G (2 SETS) 4#600KCMIL, #3/0G (3 SETS) 3#400KCMIL, #3/0G (3) 3" (2 SETS) 4#750KCMIL, #3/0G 125A 150A (3 SETS) 3#400KCMIL, #3/0G 175A 250A 200A 225A 350A 350A 250A 500A 600A 400A 700A 120N 700A 700A 135N 300A 400A 155N 700A 450A 180N 500A 800A 205N 230N 250N 270N 310N 340N 375N 385N 410N 500N 540N 620N 680N 750N 770N 460N 810N 120 135 155 180 205 230 250 270 310 340 375 385 410 500 540 620 680 750 770 810 460 NOTE: *COPPER CONDUCTORS TO BE USED FOR ALL CONDUCTORS LESS THAN 1/0 AWG. 3" 3" 3" 4" (2) 3" (2) 3" (2) 3" (2) 3" (2) 4" (2) 4" (2) 4" (3) 3" * * * * * * * * * * * * 20A 30A 50A 70A 90A 110A MAX OCPD RATING 125A 150A 175A 250A 200A 225A 350A 350A 250A 500A 600A 400A 700A 700A 700A 300A 400A 700A 450A 500A 800A MAX OCPD RATING (4 SETS) 3#400KCMIL, #4/0G (4) 3"(4 SETS) 4#350KCMIL, #4/0G1000A1000N1000(4) 3"1000A ELECTRICAL RISER NOTES: 1. CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. 2. ALUMINUM MAY BE SUBSTITUTED FOR COPPER, PROVIDED CONDUCTORS ARE NOT CONNECTED TO VIBRATING EQUIPMENT, MINIMUM CONDUCTOR SIZE IS 1/0 AWG AND NEC CONDUIT PERCENT FILL ARE MAINTAINED. TERMINATE ALUMINUM CONDUCTORS WITH COMPRESSION CONNECTORS. 3. CONTRACTOR SHALL COMPLY WITH UTILITY COMPANY'S POLICIES FOR SERVICE. CONTRACTOR SHALL PERFORM AND PAY FOR ANY WORK (TRENCHING, PLACEMENT OF CONDUITS, ETC.) CUSTOMARILY REQUIRED BY UTILITIES. CONTRACTOR SHALL PAY FOR ANY ASSOCIATED COSTS AND FEES REQUIRED FOR SERVICE. 4. SEAL UNDERGROUND CONDUIT'S ENTRY INTO SWITCHBOARD AND EQUIPMENT PER NEC 230.8 AND NEC 300.5(G). SEAL CONDUITS PASSING THROUGH EXTERIOR WALLS (DIFFERENTIAL TEMPERATURES) PER NEC 300.7(A). 5. SWITCHBOARD, ELECTRICAL WIRING TROUGHS, METER SOCKET ENCLOSURES AND PANELBOARDS SHALL BE CLEARLY FIELD MARKED TO WARN OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. 6. LABEL PANELBOARDS, EQUIPMENT WITH LAMINATED PLASTIC LABELS WITH BLACK CORE AND WHITE BACKGROUND TO INDICATE DESIGNATED NAME AND/OR FUNCTION. 7. TAGS IN FEEDER SCHEDULE CORRESPOND TO AMPACITY OF FEEDER. COORDINATE FEEDER SIZE WITH OVERCURRENT PROTECTION SHOWN. 8. PRIMARY AND SECONDARY OVERCURRENT PROTECTION AND FEEDER AND CONDUIT SIZE SHALL CORRESPOND TO TRANSFORMER SCHEDULE. 9. ALUMINUM BUS RISER IS ACCEPTABLE PROVIDED CONTRACTOR VERIFIES ADEQUATE CLEARANCES ARE MAINTAINED. 10. TVSS DEVICES SHALL BE FURNISHED WITH OVERCURRENT PROTECTION. 11. PROVIDE VERTICAL SUPPORT FOR CONDUCTORS IN ACCORDANCE WITH NEC ARTICLE 300.19. 12. SUPPORT SURFACE MOUNTED PANELS AND EQUIPMENT ENCLOSURES IN DAMP OR WET LOCATIONS A MINIMUM OF 1/4" OFF WALL PER NEC 312.2. PAINT EXPOSED STEEL WITH HEAVY ZINC RUST PREVENTATIVE PAINT. 13. FOR 1200A BREAKERS AND LARGER, COMPLY WITH NEC ARTICLE 240.87. 14. CONDUIT FOR STAIR PRESSURIZATION EQUIPMENT TO BE RUN IN STAIRWELL OR ENCASED ENCLOSURE. 15. STAIR PRESSURIZATION CIRCUITS ARE REQUIRED TO BE IN A 2 HOUR RATED ENCLOSURE OR 2 HOUR RATED CABLE TO MOTOR. FIRE ALARM RISER NOTES: 1. PROVIDE AN ADDRESSABLE, FULLY FUNCTIONAL, CODE COMPLIANT FIRE ALARM SYSTEM. PROVIDE AUXILIARY MONITORING AND CONTROL MODULES AS NEEDED. PROVIDE WIRING FOR POWER AND COMMUNICATIONS CIRCUITS. PROVIDE RACEWAYS AND CABLING FOR COMPLETE SYSTEM. 2. REFERENCE CONSTRUCTION DOCUMENTS FOR ADDITIONAL INFORMATION PERTAINING TO DEVICES AND THEIR LOCATIONS. 3. ZONE ANNUNCIATION DEVICES TO MATCH SPRINKLER ZONES, SMOKE CONTROL ZONES, AND FIRE PARTITIONS. 4. RISER DIAGRAM IS NOT INTENDED TO CONSTITUTE NOR REPLACE CONTRACTORS WIRING DIAGRAM. RISER DIAGRAM HAS BEEN PROVIDED TO CONVEY CONCEPTUAL INTERCONNECTIVITY. END OF LINE TERMINATION DEVICES OR RESISTORS ARE NOT SHOWN. 5. PROVIDE SURGE SUPPRESSION FOR DEDICATED OUTSIDE PHONE LINES, 120V INPUT POWER, AND ANY OUTSIDE WIRING (e.g. CHECK VALVE TAMPER SWITCH). 6. THE RELEASE BY MEANS OF SMOKE DETECTION OF ANY ONE DOOR IN A STAIR ENCLOSURE SHALL RESULT IN THE CLOSING OF ALL DOORS SERVING THAT STAIR. 7. DUCT DETECTORS SHALL BE PROVIDED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE SECTION 606. 8. PROVIDE DETECTORS FOR SMOKE DAMPERS IN ACCORDANCE WITH INTERNATIONAL MECHANICAL CODE SECTION 607. GROUP METERING RISER NOTES: 1. GROUP METERING EQUIPMENT SHALL BE NEMA 1 RATED WITH LOCKABLE BREAKER COMPARTMENT COVERS AND APPROVED FOR LOCAL UTILITY. 2. METER SOCKET ENCLOSURES SHALL BE LABELED BOTH ON EXTERIOR METER SOCKET COVER AND INTERIOR OF METER SOCKET (NOT ON COVER INTERIOR). LABELS SHALL BE LAMINATED PLASTIC WITH BLACK CORE AND WHITE BACKGROUND WHICH CLEARLY IDENTIFY SPACE SERVED. SWITCHBOARD AND PANELBOARD NOTES: 1. PANELS ARE TO HAVE LOCKABLE DOORS. 2. PANEL LUGS AND BREAKERS SHALL BE RATED FOR 75 DEGREE C. TERMINATION. 3. PROVIDE LOCK-ON DEVICES FOR EMERGENCY SYSTEMS, SUCH AS FIRE ALARM, DEDICATED STAIRWELL AND CORRIDOR LIGHTING. 4. PROVIDE TYPED (HAND WRITTEN IS NOT ACCEPTABLE) PANELBOARD SCHEDULES. PROVIDE UNIQUE CIRCUIT DESCRIPTIONS IN COMPLIANCE WITH NEC ARTICLE 408.4. 5. PROVIDE GROUND FAULT CIRCUIT INTERRUPTERS FOR SWIMMING POOL IN ACCORDANCE WITH NEC ARTICLE 680. BUSWAY NOTES: 1. BUSWAY SHALL BE INSTALLED TO FULLY COMPLY WITH NEC ARTICLE 368.10. ENSURE JOINTS AND FITTINGS ARE ACCESSIBLE FOR MAINTENANCE. 2. PROVIDE EXPANSION FITTINGS WHERE BUSWAY TRANSVERSES EXPANSION JOINTS AND AT LENGTHS AS PER MANUFACTURER'S RECOMMENDATIONS. EXPANSION FITTING LOCATIONS SHALL BE SELECTED TO PREVENT REDUCTION IN BUS-PLUGS. BUSWAY SUBMITTAL SHALL INCLUDE PROPOSED LOCATIONS OF EXPANSION FITTING FOR ENGINEER/ARCHITECT APPROVAL. 3. EQUALIZE WEIGHT DISTRIBUTION OF VERTICAL SECTIONS BETWEEN FLOORS. 4. BUSWAY SHALL BE INSTALLED TO OPTIMIZE NUMBER OF USEABLE BUS-PLUGS PER FLOOR. A MINIMUM OF TWO PER FLOOR IS REQUIRED UNLESS INDICATED OTHERWISE WITHIN DOCUMENTS. 5. BUSWAY SHALL BE LABELED AT EACH FLOOR TO INDICATE VOLTAGE, AMPACITY AND RISER NAME. BUS-PLUGS SHALL BE LABELED TO INDICATE THE LOAD SERVED AND OVERCURRENT PROTECTION RATING. 6. ALUMINUM BUS RISER IS ACCEPTABLE PROVIDED CONTRACTOR VERIFIES ADEQUATE CLEARANCES ARE MAINTAINED. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:22:54 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−01 08.14.18ELECTRICAL RISER DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS #3/0 MCB: 400 #1/0 MCB: 400 BUSSMAN POWER CONTROL MODULE(S) OR EQUIVALENT #3/0 MCB: 400 #3/0 MCB: 400 #3/0 MCB: 400 #3/0 MCB: 400 #3/0 MCB: 400 #3/0 MCB: 400 #4 MCB: 150 #4 MCB: 150 #4 MCB: 150 #4 MCB: 150 #1/0 MCB: 100 FUSEDPANEL #3/0 #1/0 MCB: 50 MCB: 50 (PARKING DECK) LEVEL 2 (GROUND FLOOR) LEVEL 1 (PARKING DECK) LEVEL 3 (PARKING DECK) LEVEL 4 (PARKING DECK) LEVEL 5 (PARKING DECK) LEVEL 6 (PARKING DECK) LEVEL 7 (PARKING DECK) LEVEL 8 (OFFICE) LEVEL 9 (OFFICE) LEVEL 10 (OFFICE) LEVEL 11 (OFFICE) LEVEL 12 (OFFICE) LEVEL 14 (OFFICE) LEVEL 15 (OFFICE) LEVEL 16 3000A/2500A N #3/0 3000A/3000A #3/0 RESIDENTIAL R1 N RESIDENTIAL R2 PANEL9H1400A PANEL10H1400A PANEL11H1400A PANEL12H1400A PANEL14H1400A PANEL15H1400A PANEL16H1400A PANEL16L1A400A T-16L1A 480V-208/120V 150KVA PANEL16L1A400A PANEL16L1A400A MSB-HOUSE 480V 5000A M FIRE PUMP 250HP FIRE PUMP CONTROLLER WITH INTEGRAL DISCONNECT N #1/0375N M JOCKEY PUMP 5HP SERVICE VOLTAGE: 480V LOCKED ROTOR CURRENT: XXA 20NMAIN BREAKER COMPARTMENT N #3/0 800A 400A 400A 5000A 480V UTILITYTRANSFORMER 208V UTILITYTRANSFORMER GEN 480 VOLT 750KW #3/0 500A 400A 400A 800A PARKING DECK ELEVATOR LEGALLY REQUIRED WIRING TROUGH PANEL6H1400A PANEL1H1 800A PANEL3H1400A PANEL8H1400A 800A T-1L1 480V-208/120V 112.5KVA T1125P PANEL 1L1 400A PANEL E3H1225A PANELE6H1 225A PANELE9H1225A PANELE12H1225A PANELE16H1225A PANELZ1H1 400A STUB-OUT CONDUITS TO RETAIL SPACE 400A/400 (2)4"C RETAIL 1 PROVIDE STAND-OFF STRUCTURE FROM WALL FOR INSTALLATION OF METERS AND DISCONNECT SWITCHES TO EXTEND DEVICES WITHIN 6" OF EDGE OF WIRING TROUGH TO COMPLY WITH NEC ARTICLE 110.26.A(3) (PARKING DECK) LEVEL 2 (PARKING DECK) LEVEL 3 (PARKING DECK) LEVEL 4 (PARKING DECK) LEVEL 5 (PARKING DECK) LEVEL 6 (PARKING DECK) LEVEL 7 (PARKING DECK) LEVEL 8 (OFFICE) LEVEL 9 (OFFICE) LEVEL 10 (OFFICE) LEVEL 11 (OFFICE) LEVEL 12 (OFFICE) LEVEL 14 (OFFICE) LEVEL 15 (OFFICE) LEVEL 16 CIRCUITS ROUTED IN RATED ENCLOSURE OR ELEVATOR SHAFTPANEL15L1A400A T-15L1A 480V-208/120V 150KVA PANEL15L1B400A PANEL15L1C400A PANEL14L1A400A T-14L1A 480V-208/120V 150KVA PANEL14L1B400A PANEL14L1C400A PANEL12L1A400A T-12L1A 480V-208/120V 150KVA PANEL12L1B400A PANEL12L1C400A PANEL9L1A400A T-9L1A 480V-208/120V 150KVA PANEL9L1B400A PANEL9L1C400A T112P T112S 375N 375N 385N PANEL10L1A400A T-10L1A 480V-208/120V 150KVA PANEL10L1B400A PANEL10L1C400A PANEL11L1A400A T-11L1A 480V-208/120V 150KVA PANEL11L1B400A PANEL11L1C400A LEGALLY REQ. 800A ATS-2 4-POLE EMERGENCY 400A ATS-1 4-POLE OPTIONAL 400A ATS-3 4-POLE M F-08-02 30/20 20/ 10 STAIR PRESSURIZATION T-3L1 480V-208/120V 45KVA T45P PANEL3L1225A T-6L1 480V-208/120V 45KVA PANEL6L1225A T-8L1 480V-208/120V 45KVA PANEL8L1225A PANELE1H1 225A T-E1L1 480V-208/120V 45KVA T45P PANEL E1L1 225A T45S T112.ST45S (15 SETS)#700 KCMIL, 4"C (10 SETS)-#700 KCMIL, 4"C 4-#700 KCMIL, 4"C (10 SETS)-#700 KCMIL, 4"C 400/3/400 M F-2-02 30/20 400/3/400 400/3/400 400/3/400 400/3/400 400/3/400 230N230N230N230N230N230NCT CABINET 480V TERMINATION CABINET 208V TERMINATION CABINET BY UTILITY BY UTILITY (2 SETS)4-#300 KCMIL, 4"C385N810N410N410N410N60/ 45 375N 375N 385N 375N 375N 385N 375N 375N 385N 375N 375N 385N 375N 375N 385N 375N 375N 385N PANEL 1DP 100A LIGHTING PANEL METER CT CABINET CT CABINET IS 60" X 60" MAXIMUM OF 7 SETS OF CABLES METER CT CABINET5000A-CU BUSPANEL1HTV 225A 200A180NT-1LTV 480V-208/120V 30KVA T30P PANEL 1LTV 100A T30S 100NT45PT45S T45PT45S T112P T112S T112P T112S T112P T112S T112P T112S T112P T112S PANEL7LLR100A PANELLR 800A T-7LLR 480V-208/120V 15KVA T15P T15S 30/ 30 CIRCUITS ROUTED IN RATED ENCLOSURE OR ELEVATOR SHAFTT-1LLR 480V-208/120V 15KVA T15P PANEL 1LLR 100A T15S PANEL 1L3 100A 100N810N385N385NCIRCUITS ROUTED IN RATED ENCLOSURE OR STAIRWELLCIRCUITS ROUTED IN RATED ENCLOSURE OR STAIRWELLCIRCUITS ROUTED IN RATED ENCLOSURE OR STAIRWELL400A STAIR PRESSURIZATION 460N 310N85N40N100N30N65N(2) 4" CONDUITS30NPANEL 1L3 400A PANELE10L1100A PANELE14L1100A 120N120Nc NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 10:51:14 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−02 08.14.18ELECTRICAL RISER DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1" = 1'-0"E4-02 1 ELECTRICAL RISER DIAGRAM Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION TVSS TVSS TVSS TVSS TVSS #1/0 MCB: 100 #1/0 BUSSMAN POWER CONTROL MODULES OR EQUIVALENT MCB: 150 MCB: 150 MCB: 150 #4 MCB: 150 MCB: 225 MCB: 225 MCB: 150 (9 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) (17 UNITS) #1/0 #4 #4 #4 #4 FUSEDPANEL (INTERSTITIAL) LEVEL 17 (RESIDENTIAL) LEVEL 18 (RESIDENTIAL) LEVEL 19 (RESIDENTIAL) LEVEL 20 (RESIDENTIAL) LEVEL 21 (RESIDENTIAL) LEVEL 22 (RESIDENTIAL) LEVEL 23 (RESIDENTIAL) LEVEL 24 (RESIDENTIAL) LEVEL 25 (RESIDENTIAL) LEVEL 26 (RESIDENTIAL) LEVEL 27 (RESIDENTIAL) LEVEL 28 (RESIDENTIAL) LEVEL 29 ROOF 400A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB 800A MCB PANELE22L1100A PANELE25L1100A PANELE28L1100A PANEL E19H1 225A T-E19L1 480V-208/120V 30KVA T30P PANELE19L1100A PANEL17H1800A (INTERSTITIAL) LEVEL 17 (RESIDENTIAL) LEVEL 18 (RESIDENTIAL) LEVEL 19 (RESIDENTIAL) LEVEL 20 (RESIDENTIAL) LEVEL 21 (RESIDENTIAL) LEVEL 22 (RESIDENTIAL) LEVEL 23 (RESIDENTIAL) LEVEL 24 (RESIDENTIAL) LEVEL 25 (RESIDENTIAL) LEVEL 26 (RESIDENTIAL) LEVEL 27 (RESIDENTIAL) LEVEL 28 (RESIDENTIAL) LEVEL 29 ROOF PANEL19H1400A PANEL22H1400A PANEL25H1400A PANEL28H1400A T-L17AM1 480V-208/120V 75KVA PANEL LAM1 225A T45P M F-R-01 M F-R-02 STAIR PRESSURIZATION 30/20 30/20 M 200/150 OAU-1 OUTSIDE AIR UNITS M 100/70 CT-1 COOLING TOWER M F-17-01 30/20 800/3/800 M 200/150 T-28L1 480V-208/120V 45KVA T45P PANEL28L1225A T-25L1 480V-208/120V 45KVA T45P PANEL25L1225A T-22L1 480V-208/120V 45KVA T45P PANEL22L1225A T-19L1 480V-208/120V 45KVA T45P PANEL19L1225A 60/ 60 T30S T45S T45S T45S T45S T75S 400/ 225 PANEL LAM2 225A 205N STAIR PRESSURIZATION T-17LP1 480V-208/120V 75KVA PANEL 17LP1225A T45PT75S PANEL30H1800A T-30L1 480V-208/120V 45KVA T45P PANEL30L1225A T45S 120N120N1000N410N410N410N410N205N230NRESIDENTIAL RISER-R1RESIDENTIAL RISER-R2120NPANEL 17LLR 100A T-17LLR 480V-208/120V 15KVA #3/0 T15P T15S PANEL 30LLR100A T-30LLR 480V-208/120V 15KVA #3/0 T15P T15S MCB: 50 MCB: 50 30/ 30 CIRCUITS ROUTED IN RATED ENCLOSURE OR ELEVATOR SHAFTCIRCUITS ROUTED IN RATED ENCLOSURE OR STAIRWELLCIRCUITS ROUTED IN RATED ENCLOSURE OR STAIRWELLOFFICE ELEVATOR LEGALLY REQUIRED WIRING TROUGHRESIDENTIAL CAR 1RESIDENTIAL CAR 2RESIDENTIAL CAR 360/ 60 60/ 60 M 200/150 OAU-2 M 60/35 M SUPPLY FAN MOTOR 20/20 M 200/125 M 20/20 ERU-01 270NPANEL30H2800A 810N PANEL 17LR 400A HEATERS HEAT WHEEL MOTOR RETURN AIR FANS SUPPLY FAN MOTOR110N110N c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 10:51:15 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−03 08.14.18ELECTRICAL RISER DIAGRAM401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: N.T.S.E4-03 1 ELECTRICAL RISER DIAGRAM Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION S H H SS S S S SSSSSHSS SS S S SS S SS S S S S S S S S S SSSS SS AM APARTMENT SMOKE ALARM AM APARTMENT SMOKE ALARM AM APARTMENT SMOKE ALARM VOICE ANNOUNCEMENT (AS REQUIRED) ELEVATOR LOBBY ELEVATOR LOBBY ELEVATOR LOBBY AM TAMPER SWITCH ELEV. VALVE ELEVATOR PIT ELEVATOR LOBBY ELEVATOR LOBBY ELEVATOR CAB ELEVATOR LOBBY ELEVATOR LOBBYELEVATOR LOBBY LA TAMPER SWITCH AM TAMPER SWITCH AM DRY SPRINKLER RISER PRESSURE SWITCH AM AM TAMPER SWITCH FLOW SWITCH AM WET SPRINKLER RISER AM TAMPER SWITCH FLOW SWITCH AM AM TAMPER SWITCH FLOW SWITCH AM AM TAMPER SWITCH FLOW SWITCH AM AM TAMPER SWITCH FLOW SWITCH AM AM TAMPER SWITCH FLOW SWITCH AM TAMPER SWITCH DOUBLE DECTECTOR CHECK VALVE OR POST INDICATING VALVE IF OUTDOOR PROVIDE WET RATED AM TAMPER SWITCH AM TAMPER SWITCH PHASE REVERSAL AM FAIL AM RUN AM FIRE PUMP POWER AM ELEVATOR EQUIPMENT ROOM AR STAIR PRESSURIZATION FAN (LOCATED @ LEVELS 2, 8, 17 AND ROOF) ROOF TOP UNIT START /STOP AM FAIL AM RUN AM GENERATOR APRARTMENT LOBBY OFFICE LOBBY LEVEL 1 F F F F F FACP WITH INTEGRAL TVSS TO 120V CIRCUIT BREAKER WITH LOCK-ON PROVISIONS AUTODIALER OR OFF SITE MONITORING TELEPHONE CIRCUIT TO PUBLIC ADDRESS AND SOUND SYSTEM MUTE INPUT. AR DOOR HOLDS TYPICAL RESIDENTIAL FLOOR LEVEL 1 LEVEL 2 LEVEL 3 RESIDENTIAL LEVEL X ROOF (SIMILAR TO TYPICAL FLOOR) AR HORN/SPEAKER STROBE DUCT DETECTORS FAN SHUTDOWN REMOTE TEST SWITCH R AM FAAP AREA DETECTOR WP AT FDC SUPPLY DUCT DETECTOR FAN SHUTDOWN REMOTE TEST SWITCH R LEVEL 2 LEVEL 3 ROOF (SIMILAR TO TYPICAL FLOOR) REMOTE TEST SWITCH R FAN SHUTDOWN RETURN DUCT DETECTOR AREA DETECTOR AREA DETECTOR DOOR HOLDS SMOKE DAMPER M SMOKE DAMPERM REMOTE TEST SWITCH R AR DOOR HOLDS AR DOOR HOLDS SMOKE CONTROL PANEL FOR STAIRS WITH SMOKE CONTROL MONITORING HORN/SPEAKER STROBEHORN/SPEAKER STROBE HORN/SPEAKER STROBE AM J FAN SAIL SWITCH FIRST RESPONDER TWO - WAY COMMUNICATION IS PROVIDED BY TWO - WAY RADIO HORN/SPEAKER STROBE HORN/SPEAKER STROBE PROVIDE MAIN FACP IN FIRE COMMAND CENTER AND SATELLITE FACPs AT INTERSTITIAL LEVEL (ONE DEDICATED TO OFFICE AND ONE TO APARTMENTS) FAAP OFFICE LEVEL X RESIDENTIAL LEVEL X OFFICE LEVEL X SMOKE DAMPER M TYPICAL OFFICE FLOOR AR DOOR HOLDS AREA DETECTOR AREA DETECTOR AREA DETECTOR AR DOOR HOLDS SMOKE DAMPER M HORN/SPEAKER STROBE HORN/SPEAKER STROBE HORN/SPEAKER STROBE c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 10:51:16 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−04 08.14.18TYPICAL FIRE ALARM RISER401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: N.T.S.E4-04 1 TYPICAL FIRE ALARM RISER Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION LEVEL 18 − AMENITY − R1 923’ − 10" LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" LEVEL 30 − ROOF 1049’ − 6" A-LEVEL 18 - AMENITY - R1 923' - 10" A-LEVEL 19 - R2 935' - 10" A-LEVEL 20 - R3 946' - 0" A-LEVEL 21 - R4 956' - 2" A-LEVEL 22 - R5 966' - 4" A-LEVEL 23 - R6 976' - 6" A-LEVEL 24 - R7 986' - 8" A-LEVEL 25 - R8 996' - 10" A-LEVEL 26 - R9 1007' - 0" A-LEVEL 27 - R10 1017' - 2" A-LEVEL 28 - R11 1027' - 4" A-LEVEL 29 - R12 1037' - 6" A-LEVEL 30 - ROOF PLAN 1049' - 6" LEVEL R3 949' - 9" LEVEL R3 949' - 9" LEVEL R3 949' - 9" 1 E4-05A LEVEL 1 − OFFICE LOBBY 711’ − 0" LEVEL 2 − P2 735’ − 9" LEVEL 3 − P3 746’ − 9" LEVEL 4 − P4 757’ − 9" LEVEL 5 − P5 768’ − 1" LEVEL 6 − P6 778’ − 1" LEVEL 7 − P7 788’ − 1" LEVEL 8 − P8 798’ − 1" LEVEL 9 − O1 811’ − 3" LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" LEVEL 1.5 − RES. LOBBY 715’ − 3" A-LEVEL 1 - OFFICE LOBBY 711' - 0" A-LEVEL 2 - P2 735' - 9" A-LEVEL 3 - P3 746' - 9" A-LEVEL 4 - P4 757' - 9" A-LEVEL 5 - P5 768' - 1" A-LEVEL 6 - P6 778' - 1" A-LEVEL 7 - P7 788' - 1" A-LEVEL 8 - P8 798' - 1" A-LEVEL 8 - P9 805' - 0" A-LEVEL 9 - O1 811' - 3" A-LEVEL 10 - O2 825' - 6" A-LEVEL 11 - O3 839' - 9" A-LEVEL 12 - O4 854' - 0" A-LEVEL 14 - O5 868' - 3" A-LEVEL 15 - O6 882' - 6" A-LEVEL 16 - O7 896' - 9" A-LEVEL 17 - INT 915' - 1" A-LEVEL 18 - AMENITY - R1 923' - 10" 2 E4-05A LEVEL R3 949' - 9" A-LEVEL 1.5 - RES. LOBBY 715' - 3" STW E1H1 - 11 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 11 STW E1H1 - 10STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 10 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 11 STW E1H1 - 10 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:10:29 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−05A 08.14.18LIGHTING STAIRWELL RISER401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/8" = 1'-0"E4-05A 2 STAIR #1-LEVEL 19 TO LEVEL 29 N SCALE: 1/8" = 1'-0"E4-05A 1 STAIR #1-LEVEL 1 TO LEVEL 18 Date Issue/Revision LEVEL 17 − INT 915’ − 1" LEVEL 18 − AMENITY − R1 923’ − 10" LEVEL 19 − R2 935’ − 10" LEVEL 20 − R3 946’ − 0" LEVEL 21 − R4 956’ − 2" LEVEL 22 − R5 966’ − 4" LEVEL 23 − R6 976’ − 6" LEVEL 24 − R7 986’ − 8" LEVEL 25 − R8 996’ − 10" LEVEL 26 − R9 1007’ − 0" LEVEL 27 − R10 1017’ − 2" LEVEL 28 − R11 1027’ − 4" LEVEL 29 − R12 1037’ − 6" A-LEVEL 17 - INT 915' - 1" A-LEVEL 18 - AMENITY - R1 923' - 10" A-LEVEL 19 - R2 935' - 10" A-LEVEL 20 - R3 946' - 0" A-LEVEL 21 - R4 956' - 2" A-LEVEL 22 - R5 966' - 4" A-LEVEL 23 - R6 976' - 6" A-LEVEL 24 - R7 986' - 8" A-LEVEL 25 - R8 996' - 10" A-LEVEL 26 - R9 1007' - 0" A-LEVEL 27 - R10 1017' - 2" A-LEVEL 28 - R11 1027' - 4" A-LEVEL 29 - R12 1037' - 6" LEVEL R2 935' - 9 31/32" LEVEL R3 945' - 11 31/32" R2 LEVEL 939' - 7" R3 LEVEL 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R1 927' - 7" LEVEL R2 939' - 7" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 1041' - 3" LEVEL R3 1052' - 7" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 1041' - 3" LEVEL R3 1052' - 7" LEVEL R2 1041' - 3" LEVEL R3 1051' - 5" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" R2 LEVEL 939' - 7" R3 LEVEL 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" R2 LEVEL 939' - 7" R3 LEVEL 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 935' - 9 31/32" LEVEL R3 945' - 11 31/32" LEVEL R2 935' - 9 31/32" LEVEL R3 945' - 11 31/32" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 939' - 7" LEVEL R3 949' - 9" LEVEL R2 1041' - 2 31/32" LEVEL R3 1051' - 4 31/32" LEVEL 2 − P2 735’ − 9" LEVEL 3 − P3 746’ − 9" LEVEL 4 − P4 757’ − 9" LEVEL 5 − P5 768’ − 1" LEVEL 6 − P6 778’ − 1" LEVEL 7 − P7 788’ − 1" LEVEL 8 − P8 798’ − 1" A-LEVEL 2 - P2 735' - 9" A-LEVEL 3 - P3 746' - 9" A-LEVEL 4 - P4 757' - 9" A-LEVEL 5 - P5 768' - 1" A-LEVEL 6 - P6 778' - 1" A-LEVEL 7 - P7 788' - 1" A-LEVEL 8 - P8 798' - 1" A-LEVEL 8 - P9 805' - 0" LEVEL 2 − P2 735’ − 9" 2 2.3 A-LEVEL 2 - P2 735' - 9" 4 E4-05B LEVEL 1 − OFFICE LOBBY 711’ − 0" LEVEL 2 − P2 735’ − 9" B LEVEL 1.5 − RES. LOBBY 715’ − 3" A.6.1 A.3B.1 A-LEVEL 1 - OFFICE LOBBY 711' - 0" A-LEVEL 2 - P2 735' - 9" A-LEVEL 1.5 - RES. LOBBY 715' - 3" 2 E4-05B 3 E4-05B LEVEL 9 − O1 811’ − 3" LEVEL 10 − O2 825’ − 6" LEVEL 11 − O3 839’ − 9" LEVEL 12 − O4 854’ − 0" LEVEL 14 − O5 868’ − 3" LEVEL 15 − O6 882’ − 6" LEVEL 16 − O7 896’ − 9" LEVEL 17 − INT 915’ − 1" A-LEVEL 9 - O1 811' - 3" A-LEVEL 10 - O2 825' - 6" A-LEVEL 11 - O3 839' - 9" A-LEVEL 12 - O4 854' - 0" A-LEVEL 14 - O5 868' - 3" A-LEVEL 15 - O6 882' - 6" A-LEVEL 16 - O7 896' - 9" A-LEVEL 17 - INT 915' - 1" LEVEL 8 − P8 798’ − 1" LEVEL 9 − O1 811’ − 3" LEVEL 10 − O2 825’ − 6" A-LEVEL 8 - P8 798' - 1" A-LEVEL 8 - P9 805' - 0" A-LEVEL 9 - O1 811' - 3" A-LEVEL 10 - O2 825' - 6" c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:10:56 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE4−05B 08.14.18LIGHTING STAIRWELL RISER401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 SCALE: 1/8" = 1'-0"E4-05B 1 STAIR #2 SCALE: 1/8" = 1'-0"E4-05B 2 STAIR #2-LEVEL 1 TO LEVEL 9 SCALE: 1/8" = 1'-0"E4-05B 3 STAIR #2-LEVEL 1 TO LEVEL 9 Date Issue/Revision SCALE: 1/8" = 1'-0"E4-05B 4 STAIR #2-LEVEL 1 TO LEVEL 9 SCALE: 1/8" = 1'-0"E4-05B 5 STAIR #2-LEVEL 9 TO LEVEL 17 SCALE: 1/8" = 1'-0"E4-05B 6 STAIR #2-LEVEL 8 TO LEVEL 10 POWER NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, PIU POWER, VAV'S POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. VERIFY IF EQUIPMENT IS SUPPLIED WITH INTEGRAL DISCONNECTS. IF EQUIPMENT IS NOT PROVIDED WITH INTEGRAL DISCONNECTS, PROVIDE NEC REQUIRED DISCONNECTS. PROVIDE LINE VOLTAGE THERMOSTAT REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. EQUIPMENT HAS MULTIPLE CONNECTIONS. REFER TO MECHANICAL DRAWINGS AND MANUFACTURER'S SPECIFICATIONS FOR ADDITIONAL INFORMATION. KEYNOTES: 1 2 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:27:40 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−00A 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 BOOSTER PUMPS EQUP. TAG DESCRIPTION LOCATION SERVES HP kW FLA MCA MOCP V/P BP-1 OFFICE BOOSTER PUMP PUMP ROOM OFFICE 3 X 15 55 59.5 82 460/3 BP-2 RES. BOOSTER PUMP PUMP RESIDENTIAL 3 X 20 77.8 84.2 116.2 460/3 COMPRESSORS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P COMP-1 COMPRESSOR DRY VALVE ROOM FIRE SYSTEM 1/3 3.2 208/1 COMP-2 COMPRESSOR PUMP ROOM 1ST FLOOR DRY SPRINKLER 1/6 5 115/1 COOLING TOWER EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P CT-01 COOL TOWER ROOF OFFICE COOLING TWO (2) AT 20 FOUR (4) AT 4.0 480/3 DUCTLESS SPLIT CONDENSING UNIT EQUP. TAG DESCRIPTION LOCATION SERVES HP kW FLA MCA MOCP V/P DCU-01-01 DUCTLESS CONDENSING UNIT P2 SW CORNER MAIN ELECTRICAL ROOM 15 208/1 DCU-01-02 DUCTLESS CONDENSING UNIT P2 SW CORNER MAINTENANCE ROOM 25 208/1 DCU-01-03 DUCTLESS CONDENSING UNIT P2 NW CORNER FIRE COMMAND CENTER 15 208/1 DCU-03-02 DUCTLESS CONDENSING UNIT P3 SE CORNER PARKING ELECTRICAL ROOM 15 208/1 DCU-06-02 DUCTLESS CONDENSING UNIT P6 SE CORNER PARKING ELECTRICAL ROOM 15 208/1 DCU-07-02 DUCTLESS CONDENSING UNIT P8 PLAN SE CORNER DOG WASH 15 208/1 DCU-07-03 DUCTLESS CONDENSING UNIT P7 PLAN NW CORNER GARAGE ELEVATOR MACH SHAFT 15 208/1 DCU-08-02 DUCTLESS CONDENSING UNIT P8 PLAN SE CORNER PARKING ELECTRICAL ROOM 15 208/1 DCU-17-01 DUCTLESS CONDENSING UNIT ROOF OFFICE ELEVATOR MACH SHAFT 14.1 25 208/1 DCU-17-02 DUCTLESS CONDENSING UNIT ROOF OFFICE ELEVATOR MACH SHAFT 14.1 25 208/1 DCU-R-01 DUCTLESS CONDENSING UNIT ROOF APART ELEVATOR MACH SHAFT 25 208/1 DCU-R-02 DUCTLESS CONDENSING UNIT ROOF APART ELEVATOR MACH SHAFT 15 208/1 DCU-XX-01 DUCTLESS CONDENSING UNIT P3(2), P4, P5, P6, P8(2) PLAN SE CORNER (7 TOTAL) RESID ELEV LOBBY 2 THRU 8 (7 TOTAL)15 208/1 DUCTLESS SPLIT FAN COIL UNIT EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P DFCU-01-01 DUCTLESS SPLIT INDOOR UNIT LEVEL 1 MAIN ELECTRICAL ROOM FROM OUTDOOR UNIT DFCU-01-02 DUCTLESS SPLIT INDOOR UNIT LEVEL 1 TELECOM ROOM FROM OUTDOOR UNIT DFCU-01-03 DUCTLESS SPLIT INDOOR UNIT LEVEL 1 FIRE COMMAND CENTER FROM OUTDOOR UNIT DFCU-03-02 DUCTLESS SPLIT INDOOR UNIT P3 ELECTRICAL ROOM PARKING DECK FROM OUTDOOR UNIT DFCU-06-02 DUCTLESS SPLIT INDOOR UNIT P6 ELECTRICAL ROOM PARKING DECK FROM OUTDOOR UNIT DFCU-07-02 DUCTLESS SPLIT INDOOR UNIT P8 PLAN SE CORNER DOG WASH FROM OUTDOOR UNIT DFCU-07-03 DUCTLESS SPLIT INDOOR UNIT P8 PLAN NW CORNER GARAGE ELEVATOR MACH SHAFT FROM OUTDOOR UNIT DFCU-08-02 DUCTLESS SPLIT INDOOR UNIT P8 PLAN SE CORNER ELECTRICAL ROOM PARKING DECK FROM OUTDOOR UNIT DFCU-17-01 DUCTLESS SPLIT INDOOR UNIT INTERSTITIAL OFFICE ELEVATOR MACH SHAFT NOMINAL 0.48 1 15 208/1 DFCU-17-02 DUCTLESS CONDENSING UNIT INTERSTITIAL OFFICE ELEVATOR MACH SHAFT NOMINAL 0.48 1 15 208/1 DFCU-R-01 DUCTLESS SPLIT INDOOR UNIT ROOF APARTM ELEV MACH SHAFT FROM OUTDOOR UNIT DFCU-R-02 DUCTLESS CONDENSING UNIT ROOF APARTM ELEV MACH SHAFT FROM OUTDOOR UNIT DFCU-XX-01 DUCTLESS SPLIT INDOOR UNIT RES ELEV LOBBY P2 THRU P8 (7 TOTAL) RESID ELEV LOBBY P2 THRU P8 (7 TOTAL)FROM OUTDOOR UNIT ELECTRIC HEATERS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P EH-01 WALL HEATER STAIRS, EXT DOORS, CORRIDORS AND DOORS STAIRS, EXT DOORS, CORRIDORS AND DOORS 3.0 10.8 277/1 EH-02 UNIT HEATER LEVEL 1, INTERSTITIAL, PENTHOUSE NON CONDITIONED SPACES NON CONDITIONED SPACES 5 277/1 EH-03 PLENUM HEATER LOADING DOCK, P8 CEILING AND AMNEITY PATIO CEILINGS LOADING DOCK, P8 CEILING, AMENITY PATIO CEILING 1.9 9.42 208/1 EH-04 SURFACE MOUNTED HEATER PARKING ELEVATOR LOBBY P2 THRU P6 PARKING ELEVATOR LOBBY 3.0 277/1 EH-05 TRENCH HEATER OFFICE LOBBY OFFICE LOBBY - 3 SECTIONS FOR TOTAL LENGTH 8' AT 2.0, 4'.0 AT 1.0, 8' AT 2.0 277/1 EH-06 TRENCH HEATER OFFICE LOBBY OFFICE LOBBY - 1 SECTION FOR TOTAL LENGTH 4' AT 1.0 277/1 EH-07 TRENCH HEATER RESIDENTIAL LOBBY RESIDENTIAL LOBBY - 1 SECTION FROR TOTAL LENGTH 4' AT 1.0 277/1 EH-08 TRENCH HEATER RESIDENTIAL LOBBY RESIDENTIAL LOBBY - 2 SECTIONS FOR TOTAL LENGTH 6' AT 1.5, 6' AT 1.5 277/1 EH-09 PLENUM HEATER OFFICE SHELL OFFICE SHELL 5 FLOORS 5.0 18 277/1 FAN COIL UNITS EQUP. TAG DESCRIPTION LOCATION SERVES HP kW FLA MCA MOCP V/P FCU-01-01 FAN COIL UNIT LEVEL1 OFFICE LOBBY 3/4 15 36.2 AND 18.1 53.8 AND 22.7 60 AND 25 208/1 FCU-01-02 FAN COIL UNIT LEVEL 1 OFF LOBBY INTERIOR 3/4 8 6 44.7 45 208/1 FCU-A FAN COIL UNIT APARTMENT MECH CLOSET STUDIO AND 1 BEDROOM 1/3 5 2.6 24.9 25 208/1 FCU-B FAN COIL UNIT APARTMENT MECH CLOSET 2 BEDROOM 1/3 8 2.6 36.2 40 208/1 FAN SCHEDULE EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P F-01-01 INLINE FAN GENERATOR ROOF GENERATOR ROOM 1/4 120/1 F-01-02 INLINE FAN FIRE PUMP ROOM PUMP ROOM 1/4 120/1 F-01-03 INLINE FAN LOADING DOCK ABOVE CEIING LOADING DOCK 1/4 120/1 F-01-04 INLINE FAN SUSPENDED OUTSIDE ROOM SINGLE TOILET/JANITOR CLOSET 1/6 120/1 F-01-05 INLINE FAN SUSPENDED OUTSIDE ROOM EMERGENCY ELECTRICAL ROOM 1/6 120/1 F-01-06 INLINE FAN SUSPENDED OUTSIDE ROOM OA FCU-01-01,02 1/6 120/1 F-01-07 INLINE FAN TRASH ROOM TRASH ROOM 1/2 208/1 F-02-01 VANE AXIAL FAN LEVEL 2 PARKING NW CORNER STAIR PRESS #2 GARAGE 3 480/3 F-07-01 INLINE FAN P7 PLAN SE CORNER DOG WASH 1/6 NOM 120/1 F-08-01 VANE AXIAL FAN P8.5 PLAN NW CORNER STAIR PRESS #2 OFFICE 2 480/3 F-17-01 VANE AXIAL FAN INTERSTITIAL PLAN NE CORNER STAIR PRESS #1 OFFICE/GARAGE 7.5 480/3 F-17-02 INLINE FAN CHEMICAL POOL ROOM POOL CHEMICAL INTAKE FAN 1/6 120/1 F-17-03 INLINE FAN INTERSTITIAL SE CORNER POOL CHEMICAL EXHAUST FAN 1/6 120/1 F-18-01 CABINET POOL RESTROOM CEILING AMENITY POOL SINGLE TOILET 30.4W 120/1 F-18-02 INLINE FAN CORRIDOR TO POOL ABOVE CEILIING AMENITY TOILETS 1/6 120/1 F-A CEILING FAN APARTMENT RESTROOM APARTMENT TOILETS 0.13 0.29 120/1 F-PH-01 INLINE FAN PENTHOUSE PENTHOUSE VENTILATION 1/4 120/1 F-R-01 VANE AXIAL FAN PENTHOUSE ROOF STAIR PRESSURIZATION #1 5 480/3 F-R-02 VANE AXIAL FAN ROOF STAIR PRESSURIZATION #2 5 480/3 F-XX-01 INLINE FAN ELECTRICAL ROOM ELECTRICAL ROOMS - OFFICE 1/6 120/1 HEAT PUMPS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P CU-01-01 HEAT PUMP P3 OFFICE LOBBY 1.4 25.2 40 208/1 CU-01-02 HEAT PUMP P3 OFFICE LOOBBY 1.4 25.2 40 208/1 CU-01-03 HEAT PUMP - FUTURE P3 FUTURE RES LOBBY 0.6 14.2 25 208/1 CU-01-04 HEAT PUMP - FUTURE P3 FUTURE RES LOBBY 0.6 14.2 25 208/1 CU-01-05 HEAT PUMP - FUTURE P3 FUTURE RETAIL CU-01-06 HEAT PUMP - FUTURE P3 FUTURE RETAIL CU-A 1.5 TON HEAT PUMP ROOF APARTMENT UNITS 1.1 12.4 20 208/1 CU-B 2 TON HEAT PUMP ROOF APARTMENT UNITS 1.1 14.7 25 208/1 JOCKEY PUMP EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P JP-1 JOCKEY PUMP PUMP ROOM FIRE SERVICE 5 460/3 OUTSIDE AIR UNIT WITH GAS HEAT EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P OAU-01 DEDICATED OUTSIDE AIR UNIT ROOF APARTMENT VENTILATION 7.5 141.8 150 480/3 OAU-02 DEDICATED OUTSIDE AIR UNIT ROOF APARTMENT VENTILATION 7.5 141.8 150 480/3 POWER INDUCTION UNIT EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P PIU-XX-01 POWER INDUCTION UNIT OFF FLR ONE (1) ON EACH FLR (7 FLRS) OFFICE CORE 1/4 '--120/1 PIU-XX-02 POWER INDUCTION UNIT OFF FLR ONE (1) ON FLRS (6,7 FLRS) OFFICE NORTH 1/4 6 277/1 PIU-XX-03 POWER INDUCTION UNIT OFF FLR ONE (1) ON FLRS (6,7 FLRS) OFFICE EAST 1/4 6 277/1 PIU-XX-04 POWER INDUCTION UNIT OFF FLR ONE (1) ON FLRS (6,7 FLRS) OFFICE SOUTH 1/4 6 277/1 PIU-XX-05 POWER INDUCTION UNIT OFF FLR ONE (1) ON FLRS (6,7 FLRS) OFFICE WEST 1/4 6 277/1 PUMP EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P P-01 PUMP PENTHOUSE OFFICE CWSR LOOP 30 480/3 P-02 PUMP PENTHOUSE OFFICE CWSR LOOP 30 480/3 P-03 PUMP PENTHOUSE OFFICE CWSR LOOP 30 480/3 P-04 PUMP PENTHOUSE TOWER CWSR LOOP 20 480/3 P-05 PUMP PENTHOUSE TOWER CWSR LOOP 20 480/3 P-06 PUMP PENTHOUSE TOWER CWSR LOOP 20 480/3 SUMP PUMPS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P SP-1 SUMP PUMP ELEVATOR S1 ELEVATOR SUMP 0.5 8 208/1 SP-2 SUMP PUMP ELEVATOR O3 AND O4 ELEVATOR SUMP 0.5 8 208/1 SP-3 SUMP PUMP ELEVATOR O1 AND O2 ELEVATOR SUMP 1.0 14 208/1 SP-4 SUMP PUMP ELEVATOR R1 AND R2 ELEVATOR SUMP 1.0 14 208/1 SP-5 SUMP PUMP ELEVATOR R3 ELEVATOR SUMP 0.5 8 208/1 SP-6 LIFT STATION TRASH ROOM ELEVATOR SUMP 0.5 8 208/1 WATER COOLED ENERGY RECOVERY UNIT EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P ERU-01 WATER COOLED INDOOR SELF CONTAINED UNIT SCHEDULE EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P SCU-XX-01 SELF CONTAINED UNIT MECHANICAL ROOM ONE (1) ON EACH FLR (7FLRS) OFFICE HVAC UNIT 2 AT 7.5 93.8 98.5 110 480/3 WATER HEATERS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P WH-1 TANK TYPE WATER HEATER AMENITY JANITOR'S CLOSET AMENITY RESTROOMS 2.5 208/1 WH-2 TANK TYPE WATER HEATER BOH JANITOR'S CLOSET AMENITY RESTROOMS 2.5 208/1 WH-3 INSTANTANEOUS WATER HEATER DOG SPA DOG SPA 6.2 30 208/1 WH-4 INSTANTANEOUS WATER HEATER AMENITY DECK POOL SINK 4.1 208/1 WH-A WATER HEATER UNITS UNITS 5.5 208/1 WH-O WATER HEATER OFFICE JANITOR'S CLOSET OFFICE RESTROOMS 3 208/1 IRRIGATION PUMP EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P IRP-1 IRRIGATION PUMP PUMP ROOM IRRIGATION AT AMENITY LEVEL 5 460/3 CIRCULATION PUMPS EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P CP-O CIRC PUMP OFFICE JANITOR'S CLOSET OFFICE RESTROOMS 1/8 1.45 115/1 FIRE PUMP EQUP. TAG DESCRIPTION LOCATION ~SERVES HP kW FLA MCA MOCP V/P FP-1 FIRE PUMP PUMP ROOM FIRE SERVICE 250 460/3 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 2 1 1 2 1 c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:27:43 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−00B 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 8:27:46 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−00C 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:0 A 0 A Total Load:0 VA 0 VA 23 Space -- -- 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 24 21 IT CABINET 15 A 1 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 22 19 ---- -- 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 20 17 FAN COIL UNIT - FCU-A 30 A 2 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 18 15 ---- -- 0 VA 0 VA 1 20 A BATHROOM 16 13 CONDENSING UNIT - CU-A 30 A 2 0 VA 0 VA 1 20 A REFRIGERATOR 14 11 ---- -- 0 VA 0 VA 1 20 A MICROWAVE 12 9 WATER HEATER - WH-A 40 A 2 0 VA 0 VA 1 20 A DISHWASHER 10 7 ---- -- 0 VA 0 VA 1 20 A LAUNDRY 8 5 DRYER 30 A 2 0 VA 0 VA 1 20 A DISPOSAL 6 3 ---- -- 0 VA 0 VA 1 20 A KITCHEN RECEPTACLE 4 1 RANGE 50 A 2 0 VA 0 VA 1 20 A KITCHEN RECEPTACLE 2 CKT Breaker Type Circuit Description Trip Poles A B Poles Trip Circuit Description Breaker Type CKT TYPICAL RESIDENTIAL LOAD CENTER Notes: Enclosure:MCB Rating:125 A Mounting:Recessed Wires:3 Mains Rating:125 A Supply From:RESIDENTIAL METER CENTER Phases:1 Mains Type:MCB Location:Volts:208/120V A.I.C. Rating: LOAD CENTER TYPICAL 1BR (TYPICAL) Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:0 A 0 A Total Load:0 VA 0 VA 29 Space -- -- 0 VA 0 VA -- -- Space 30 27 Space -- -- 0 VA 0 VA -- -- Space 28 25 Space -- -- 0 VA 0 VA -- -- Space 26 23 LIGHTS/RECEPTACLE 15 A 1 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 24 21 IT CABINET 15 A 1 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 22 19 ---- -- 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 20 17 FAN COIL UNIT - FCU-B 40 A 2 0 VA 0 VA 1 15 A LIGHTS/RECEPTACLE 18 15 ---- -- 0 VA 0 VA 1 20 A BATHROOM 16 13 CONDENSING UNIT - CU-B 30 A 2 0 VA 0 VA 1 20 A REFRIGERATOR 14 11 ---- -- 0 VA 0 VA 1 20 A MICROWAVE 12 9 WATER HEATER - WH-A 40 A 2 0 VA 0 VA 1 20 A DISHWASHER 10 7 ---- -- 0 VA 0 VA 1 20 A LAUNDRY 8 5 DRYER 30 A 2 0 VA 0 VA 1 20 A DISPOSAL 6 3 ---- -- 0 VA 0 VA 1 20 A KITCHEN RECEPTACLE 4 1 RANGE 50 A 2 0 VA 0 VA 1 20 A KITCHEN RECEPTACLE 2 CKT Breaker Type Circuit Description Trip Poles A B Poles Trip Circuit Description Breaker Type CKT TYPICAL RESIDENTIAL LOAD CENTER Notes: Enclosure:MCB Rating:150 A Mounting:Recessed Wires:3 Mains Rating:150 A Supply From:RESIDENTIAL METER CENTER Phases:1 Mains Type:MCB Location:Volts:208/120V A.I.C. Rating: LOAD CENTER TYPICAL 2BR (TYPICAL) Date Issue/Revision PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:57:05 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−01A 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 1280 VA 125.00% 1600 VA Motor-RESIDENTIAL ELEVATOR 17700 VA 85.00% 15045 VA Receptacle 12300 VA 90.65% 11150 VA Power 3000 VA 100.00% 3000 VA Other 84 VA 100.00% 84 VA Total Est. Demand:197 A Motor 58303 VA 103.99% 60628 VA Total Conn.:198 A Lighting 1232 VA 125.00% 1540 VA Total Est. Demand:163993 VA Heating 63100 VA 100.00% 63100 VA Total Conn. Load:164875 VA HVAC 8000 VA 100.00% 8000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:204 A 210 A 186 A Total Load:55901 VA 57379 VA 51596 VA 47 0 VA -- --Space 48 45 0 VA -- --Space 46 43 0 VA -- --Space 44 41 42 39 40 37 38 35 36 33 EH-08 20 A 1 3000...34 31 Lighting GARAGE 20 A 1 800... 1000... 1 20 A EH-7 32 29 Lighting 20 A 1 400... 64 VA 1 20 A Other 30 27 EH-02 20 A 1 5000... 608... 1 20 A Lighting 28 25 Lighting - Dwelling Unit 20 A 1 0 VA 576... 1 20 A Lighting 26 23 Motor-RESIDENTIAL ELEVATOR 20 A 1 5000... 5000... 1 20 A EH-02 24 21 EH-02 20 A 1 5000... 433... -- -- -- 22 19 -- -- -- 1333... 433... -- -- -- 20 17 -- -- -- 1333... 433... 3 20 A F-01-01 18 15 F-02-01 20 A 3 1333... 2100... -- -- -- 16 13 EH-01 20 A 1 3000... 2100... -- -- -- 14 11 EH-06 20 A 1 1000... 2100... 3 20 A IRP-1 12 9 EH-02 20 A 1 5000... 5000... 1 20 A EH-05 10 7 EH-01 20 A 1 3000... 5000... 1 20 A EH-02 8 5 -- -- -- 3328... 3000... 1 20 A EH-01 6 3 -- -- -- 2693... 3000... 1 20 A EH-01 4 1 T-1L1 200 A 3 3572... 3000... 1 20 A EH-01 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:800 A Supply From:MSB-HOUSE Phases:3 Mains Type:MLO Location:MAIN ELECTRICAL ROOM...Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 1H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Motor-RESIDENTIAL ELEVATOR 17700 VA 85.00% 15045 VA Receptacle 12300 VA 90.65% 11150 VA Power 3000 VA 100.00% 3000 VA Other 84 VA 100.00% 84 VA Total Est. Demand:262 A Motor 46703 VA 104.98% 49028 VA Total Conn.:266 A Lighting 64 VA 125.00% 80 VA Total Est. Demand:94483 VA Heating 8100 VA 100.00% 8100 VA Total Conn. Load:95948 VA HVAC 8000 VA 100.00% 8000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:306 A 224 A 286 A Total Load:35726 VA 26934 VA 33288 VA 89 -- -- -- 0 VA 2704... -- -- --90 87 -- -- -- 0 VA 2704... 2 40 A FCU-01-04 88 85 1L2 400 A 3 0 VA 4649... -- -- --86 83 4649... 2 60 A FCU-01-03 84 81 DOOR POWER 20 A 1 500... 1400... -- -- -- 82 79 ADA DOOR OPENER 20 A 1 500... 1400... 2 20 A Motor-RESIDENTIAL ELEVATOR 80 77 Receptacle 20 A 1 540... 600... 1 20 A AMAZON LOCKER 78 75 DOOR POWER 20 A 1 500... 180... 1 20 A Receptacle 76 73 Receptacle 20 A 1 180... 500... 1 20 A ADA DOOR OPENER 74 71 Receptacle 20 A 1 180... 180... 1 20 A Receptacle 72 69 -- -- -- 1000... 720... 1 20 A Receptacle 70 67 DCU-08-02 20 A 2 1000... 250... -- -- -- 68 65 -- -- -- 250... 250... 2 20 A PARKING PAY CENTER 66 63 PARKING GATE 20 A 2 250... 600... -- -- -- 64 61 -- -- -- 1000... 600... 2 20 A DOCK LEVELER 62 59 DCU-01-02 20 A 2 1000... 64 VA 1 20 A Lighting 60 57 -- -- -- 3300... 1000... -- -- -- 58 55 CU-01-02 20 A 2 3300... 1000... 2 20 A DCU-01-01 56 53 -- -- -- 1000... 3300... -- -- -- 54 51 DCU-01-03 20 A 2 1000... 3300... 2 20 A CU-01-01 52 49 Receptacle 20 A 1 360... 720... 1 20 A Receptacle 50 47 Receptacle 20 A 1 1440... 360... 1 20 A Receptacle 48 45 Receptacle 20 A 1 1080... 1260... 1 20 A Receptacle 46 43 -- -- -- 3300... 4649... -- -- -- 44 41 FCU-01-01 20 A 2 3300... 4649... 2 60 A FCU-01-02 42 39 -- -- -- 550... 720... 1 20 A Receptacle 40 37 SP-1 20 A 2 550... 900... -- -- -- 38 35 -- -- -- 550... 900... 2 20 A SP-6 36 33 SP-2 20 A 2 550... 900... -- -- -- 34 31 -- -- -- 900... 900... 2 20 A SP-3 32 29 SP-4 20 A 2 900... 550... -- -- -- 30 27 F-01-06 20 A 1 500... 550... 2 20 A SP-5 28 25 F-01-04 20 A 1 500... 500... 1 20 A F-01-05 26 23 F-01-02 20 A 1 700... 720... 1 20 A Receptacle 24 21 Receptacle 20 A 1 540... 250... -- -- -- 22 19 COMP-2 20 A 1 1700... 250... 2 20 A OVERHEAD DOOR 20 17 -- -- -- 1000... 56 VA 1 20 A Other 18 15 EH-03 20 A 2 1000... 180... 1 20 A Receptacle 16 13 -- -- -- 2050... 540... 1 20 A Receptacle 14 11 WH-2 25 A 2 2050... 550... -- -- -- 12 9 -- -- -- 1000... 550... 2 20 A F-01-07 10 7 EH-03 20 A 2 1000... 700... 1 20 A F-01-03 8 5 -- -- -- 850... 0 VA -- -- -- 6 3 COMP-1 20 A 2 850... 0 VA -- -- -- 4 1 Other 20 A 1 28 VA 1800... 3 100 A 1L3 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:400 A Mounting:Surface Wires:4 MCB Rating:400 A Supply From:T-1L1 Phases:3 Mains Type:MCB Location:MAIN ELECTRICAL ROOM...Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 1L1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:14 A Total Conn.:14 A Total Est. Demand:5040 VA Motor-RESIDENTIAL ELEVATOR 4500 VA 100.00% 4500 VA Total Conn. Load:5040 VA Receptacle 540 VA 100.00% 540 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:26 A 22 A 0 A Total Load:2790 VA 2250 VA 0 VA 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 2250... -- -- -- 4 1 Receptacle 20 A 1 540... 2250... 2 20 A Motor-RESIDENTIAL ELEVATOR 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Enclosure:Type 1 Mains Rating:100 A Mounting:Surface Wires:4 MCB Rating:100 A Supply From:T-1LTV Phases:3 Mains Type:MCB Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 1LTV 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:17 A Total Conn.:15 A Motor-RESIDENTIAL ELEVATOR 4500 VA 100.00% 4500 VA Total Est. Demand:14415 VA Receptacle 540 VA 100.00% 540 VA Total Conn. Load:12540 VA Motor 7500 VA 125.00% 9375 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:20 A 18 A 9 A Total Load:5290 VA 4750 VA 2500 VA 47 48 45 46 43 44 41 0 VA -- -- -- 42 39 2250... -- -- -- 40 37 2790... 3 50 A T-1LTV 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 -- -- -- 2500...6 3 -- -- -- 2500...4 1 TRANSFORMER HOIST 20 A 3 2500...2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:225 A Supply From:Z1H1 Phases:3 Mains Type:MLO Location:TRANSFORMER AREA 118 Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 1HTV Notes: Total Est. Demand:17 A Total Conn.:15 A Motor-RESIDENTIAL ELEVATOR 4500 VA 100.00% 4500 VA Total Est. Demand:14415 VA Receptacle 540 VA 100.00% 540 VA Total Conn. Load:12540 VA Motor 7500 VA 125.00% 9375 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:20 A 18 A 9 A Total Load:5290 VA 4750 VA 2500 VA 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 -- -- -- 2500...6 3 -- -- -- 4750...4 1 1HTV 20 A 3 5290...2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:ATS-3 Phases:3 Mains Type:MLO Location:MAIN ELECTRICAL ROOM...Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: Z1H1 Lighting GARAGE 6592 VA 125.00% 8240 VA Lighting STAIRWELL 12000 VA 125.00% 15000 VA Motor-RESIDENTIAL ELEVATOR 42500 VA 72.00% 30600 VA Receptacle 80700 VA 56.20% 45350 VA Power 73500 VA 100.00% 73500 VA Other 7841 VA 100.00% 7841 VA Motor 811453 VA 103.64% 840966 VA Lighting - Dwelling Unit 1680 VA 100.00% 1680 VA Total Est. Demand:2235 A Lighting 13240 VA 125.00% 16550 VA Total Conn.:2384 A Heating 439800 VA 100.00% 439800 VA Total Est. Demand:1857889 VA HVAC 71600 VA 100.00% 71600 VA Total Conn. Load:1982258 VA Elevator 423000 VA 73.00% 308790 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:2384 A Total Conn. Load:1982258 VA 8 7 6 5000A BUS 3 5000 A 5000 A 1055142 VA 5 3H1 3 400 A 400 A 197984 VA 4 1H1 3 800 A 800 A 164875 VA 3 ATS-2 3 400 A 400 A 526899 VA 2 ATS-1 3 400 A 400 A 25650 VA 1 ATS-3 3 400 A 400 A 12540 VA CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Enclosure:TYPE 1 MCB Rating:5000 Mounting:FLOOR MOUNTED Wires:4 Mains Rating:5000 Supply From:UTILITY 480V XFMR Phases:3 Mains Type:MCB Location:MAIN ELECTRICAL ROOM...Volts:480/277 Wye A.I.C. Rating:65,000 Switchboard: MSB-HOUSE 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:5 A Total Conn.:5 A Total Est. Demand:1800 VA Total Conn. Load:1800 VA Receptacle 1800 VA 100.00% 1800 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:15 A 0 A 0 A Total Load:1800 VA 0 VA 0 VA 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 Receptacle 20 A 1 900... 900... 1 20 A Receptacle 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:100 A Supply From:1L1 Phases:3 Mains Type:MLO Location:TELECOM 121 Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 1L3 Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:48 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−01B 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 Notes: Receptacle 1080 VA 100.00% 1080 VA Total Est. Demand:516 A Other 2200 VA 100.00% 2200 VA Total Conn.:634 A Motor 97700 VA 116.35% 113675 VA Total Est. Demand:429395 VA Lighting 3072 VA 125.00% 3840 VA Total Conn. Load:526899 VA Elevator 423000 VA 73.00% 308790 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:628 A 639 A 638 A Total Load:173940 VA 176640 VA 176321 VA 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 -- -- -- 3072...24 21 -- -- -- 3240...22 19 T-1LLR 50 A 3 540...20 17 -- -- -- 2130... 9000... -- -- -- 18 15 -- -- -- 2130... 9000... -- -- -- 16 13 BP-2 20 A 3 2130... 9000... 3 20 A BP-1 14 11 -- -- -- 3333... 5000... -- -- -- 12 9 -- -- -- 3333... 5000... -- -- -- 10 7 PARKING DECK LEGALLY REQUIRED... 20 A 3 3333... 5000... 3 20 A RESIDENTIAL LEGALLY REQUIRED... 8 5 -- -- -- 2100... 5766... -- -- -- 6 3 -- -- -- 2100... 5766... -- -- -- 4 1 JP-1 20 A 3 2100... 5766... 3 400 A 17LR 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:800 A Supply From:ATS-2 Phases:3 Mains Type:MLO Location:MAIN ELECTRICAL ROOM...Volts:480/277 Wye A.I.C. Rating:65,000 FUSED Panel: 1LR 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Motor-RESIDENTIAL ELEVATOR 7200 VA 95.00% 6840 VA Receptacle 57060 VA 58.76% 33530 VA Power 500 VA 100.00% 500 VA Other 742 VA 100.00% 742 VA Motor 641950 VA 104.60% 671463 VA Total Est. Demand:1277 A Lighting - Dwelling Unit 880 VA 100.00% 880 VA Total Conn.:1269 A Lighting 2688 VA 125.00% 3360 VA Total Est. Demand:1061404 VA Heating 316500 VA 100.00% 316500 VA Total Conn. Load:1055142 VA HVAC 27800 VA 100.00% 27800 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:1351 A 1244 A 1221 A Total Load:373292 VA 343635 VA 338217 VA 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 -- -- -- 2330...34 31 -- -- -- 2452...32 29 17H1 400 A 3 2593...30 27 28 25 26 23 2216... -- -- -- 24 21 1876... -- -- -- 22 19 2015... 3 20 A 9H1 20 17 -- -- -- 6700... 8860... -- -- -- 18 15 -- -- -- 2136... 1954... -- -- -- 16 13 15H1 400 A 3 2112... 1458... 3 400 A 14H1 14 11 -- -- -- 7940... 9980... -- -- -- 12 9 -- -- -- 1346... 1440... -- -- -- 10 7 12H1 400 A 3 1808... 1860... 3 400 A 11H1 8 5 -- -- -- 1258... 1060... -- -- -- 6 3 -- -- -- 1290... 1014... -- -- -- 4 1 10H1 400 A 3 1400... 2148... 3 400 A 16H1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:5000 A Supply From:MSB-HOUSE Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating: Branch Panel: 5000A BUS 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 3072 VA 125.00% 3840 VA Total Est. Demand:37 A Lighting STAIRWELL 12000 VA 125.00% 15000 VA Total Conn.:31 A Other 4815 VA 100.00% 4815 VA Total Est. Demand:30701 VA Lighting - Dwelling Unit 800 VA 100.00% 800 VA Total Conn. Load:25650 VA Lighting 5160 VA 125.00% 6450 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:32 A 26 A 36 A Total Load:8734 VA 7119 VA 9803 VA 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 Lighting STAIRWELL 20 A 1 192... 96 VA 1 20 A Lighting STAIRWELL 18 15 744... 1 20 A Lighting 16 13 Lighting STAIRWELL 20 A 1 672... 96 VA 1 20 A Lighting 14 11 Lighting - STAIRWELL 20 A 1 2784... 768... 1 20 A Lighting STAIRWELL 12 9 2976... 1 20 A Lighting - STAIRWELL 10 7 Lighting GARAGE 20 A 1 672... 640... 1 20 A Lighting - Dwelling Unit 8 5 -- -- -- 2603... 3456... -- -- -- 6 3 -- -- -- 998... 2443... -- -- -- 4 1 T-EL1 20 A 3 710... 5974... 3 20 A EH3 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:225 A Supply From:ATS-1 Phases:3 Mains Type:MLO Location:MAIN ELECTRICAL ROOM...Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: E1H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:12 A Total Conn.:12 A Total Est. Demand:4311 VA Total Conn. Load:4311 VA Other 4311 VA 100.00% 4311 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:6 A 9 A 22 A Total Load:710 VA 998 VA 2603 VA 35 36 33 34 31 32 29 -- -- -- 0 VA 30 27 -- -- -- 0 VA 28 25 E10L1 100 A 3 210...26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 500... -- -- -- 8 5 Other 20 A 1 28 VA 2575... -- -- -- 6 3 Lighting 20 A 1 28 VA 970... 3 100 A 1DP 4 1 Other 20 A 1 0 VA 0 VA 1 20 A Other 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Enclosure:Type 1 Mains Rating:225 A Mounting:Surface Wires:4 MCB Rating:100 A Supply From:T-EL1 Phases:3 Mains Type:MCB Location:MAIN ELECTRICAL ROOM...Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: E1L1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:21 A Receptacle 1080 VA 100.00% 1080 VA Total Conn.:19 A Other 2200 VA 100.00% 2200 VA Total Est. Demand:7648 VA Motor 500 VA 125.00% 625 VA Total Conn. Load:6767 VA Lighting 3072 VA 125.00% 3840 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:5 A 30 A 29 A Total Load:540 VA 3240 VA 3072 VA 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 Other 20 A 1 2200...10 7 8 5 Lighting 30 A 1 2816... 256... 1 20 A Lighting 6 3 Receptacle 20 A 1 540... 500... 1 20 A Motor 4 1 Receptacle 20 A 1 360... 180... 1 20 A Receptacle 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Enclosure:Type 1 Mains Rating:100 A Mounting:Surface Wires:4 MCB Rating:50 A Supply From:T-1LLR Phases:3 Mains Type:MCB Location:MAIN ELECTRICAL ROOM...Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 1LLR Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION Notes: Total Est. Demand:11 A Total Conn.:11 A Total Est. Demand:4045 VA Total Conn. Load:4045 VA Other 4045 VA 100.00% 4045 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:9 A 22 A 4 A Total Load:970 VA 2575 VA 500 VA 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 Lighting 20 A 1 500...6 3 Other 20 A 1 2200... 375... 1 20 A Other 4 1 Other 20 A 1 70 VA 900... 1 20 A Other 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:100 A Supply From:E1L1 Phases:3 Mains Type:MLO Location:MAIN ELECTRICAL ROOM...Volts:120/208 Wye A.I.C. Rating:10,000 DIMMING PANEL 1DP 2. 2.. SHADED AREAS SHOWN FOR LUG LOAD VERIFICATION PURPOSED ONLY. 1. PROVIDE FEEDTHRU LUGS Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:0 A 0 A 0 A Total Load:0 VA 0 VA 0 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:1L1 Phases:3 Mains Type:MLO Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 1L2 PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:51 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−03 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 2240 VA 125.00% 2800 VA Motor-RESIDENTIAL ELEVATOR 13100 VA 85.00% 11135 VA Receptacle 9720 VA 100.00% 9720 VA Power 70000 VA 100.00% 70000 VA Other 0 VA 0.00% 0 VA Total Est. Demand:238 A Motor 6000 VA 116.67% 7000 VA Total Conn.:238 A Lighting 1088 VA 125.00% 1360 VA Total Est. Demand:197811 VA Heating 60200 VA 100.00% 60200 VA Total Conn. Load:197984 VA HVAC 35800 VA 100.00% 35800 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:300 A 254 A 180 A Total Load:80405 VA 67585 VA 49996 VA 47 ---- --2128...48 45 ---- --4202...46 43 6H1 400 A 3 4579...44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 Lighting GARAGE 20 A 1 96 VA 2000... 1 20 A EH-04 14 11 Lighting GARAGE 20 A 1 768... 2000... 1 20 A EH-04 12 9 Lighting 20 A 1 64 VA 2000... 1 20 A EH-04 10 7 Motor-RESIDENTIAL ELEVATOR 20 A 1 3000... 2000... 1 20 A EH-04 8 5 EH-01 20 A 1 3000... 2298... -- -- -- 6 3 EH-01 20 A 1 3000... 2050... -- -- -- 4 1 EH-01 20 A 1 3000... 2452... 3 80 A T-3L1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:MSB-HOUSE Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 3H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Total Est. Demand:188 A Motor-RESIDENTIAL ELEVATOR 8600 VA 95.00% 8170 VA Total Conn.:189 A Receptacle 3600 VA 100.00% 3600 VA Total Est. Demand:67570 VA Power 30000 VA 100.00% 30000 VA Total Conn. Load:68000 VA HVAC 25800 VA 100.00% 25800 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:208 A 171 A 195 A Total Load:24520 VA 20500 VA 22980 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 -- -- -- 3300...30 27 CU-01-06 20 A 2 3300... 180... 1 20 A Receptacle 28 25 -- -- -- 3300... 3300... -- -- -- 26 23 CU-01-03 20 A 2 3300... 3300... 2 20 A CU-01-05 24 21 -- -- -- 1000... 3300... -- -- -- 22 19 DCU-03-02 20 A 2 1000... 3300... 2 20 A CU-01-04 20 17 Receptacle 20 A 1 540... 540... 1 20 A Receptacle 18 15 720... 1 20 A Receptacle 16 13 Receptacle 20 A 1 900... 720... 1 20 A Receptacle 14 11 -- -- -- 1000... 5000... -- -- -- 12 9 DCU-XX-01 20 A 2 1000... 5000... 2 20 A Power 10 7 -- -- -- 1000... 5000... -- -- -- 8 5 DCU-XX-01 20 A 2 1000... 5000... 2 20 A CAR CHARGING 6 3 -- -- -- 5000... 1000... -- -- -- 4 1 CAR CHARGING 20 A 2 5000... 1000... 2 20 A HVAC 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:225 A Mounting:Surface Wires:4 MCB Rating:150 A Supply From:T-3L1 Phases:3 Mains Type:MCB Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 3L1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 1792 VA 125.00% 2240 VA Total Est. Demand:17 A Lighting STAIRWELL 4512 VA 125.00% 5640 VA Total Conn.:14 A Other 504 VA 100.00% 504 VA Total Est. Demand:14520 VA Lighting - Dwelling Unit 800 VA 100.00% 800 VA Total Conn. Load:11872 VA Lighting 4288 VA 125.00% 5360 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:22 A 9 A 13 A Total Load:5974 VA 2443 VA 3456 VA 47 ---- --3456...48 45 ---- --2443...46 43 E6H1 225 A 3 5206...44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 Lighting GARAGE 20 A 1 768...2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:225 A Supply From:E1H1 Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: E3H1 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:53 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−06 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 1472 VA 125.00% 1840 VA Motor-RESIDENTIAL ELEVATOR 4500 VA 95.00% 4275 VA Receptacle 6120 VA 100.00% 6120 VA Power 40000 VA 100.00% 40000 VA Other 0 VA 0.00% 0 VA Total Est. Demand:133 A Motor 6000 VA 116.67% 7000 VA Total Conn.:131 A Lighting 928 VA 125.00% 1160 VA Total Est. Demand:110449 VA Heating 40200 VA 100.00% 40200 VA Total Conn. Load:109103 VA HVAC 10000 VA 100.00% 10000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:177 A 163 A 77 A Total Load:45794 VA 42025 VA 21285 VA 47 1659...-- ----48 45 2512...-- ----46 43 2725...3 400 A 8H1 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 EH-01 20 A 1 3000...8 5 -- -- -- 3900... 832... 1 20 A Lighting GARAGE 6 3 -- -- -- 1290... 4000... 1 20 A EH-01 4 1 T-1L6 80 A 3 1354... 2000... 1 20 A EH-04 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:3H1 Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 6H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Total Est. Demand:86 A Receptacle 2340 VA 100.00% 2340 VA Total Conn.:84 A Power 20000 VA 100.00% 20000 VA Total Est. Demand:30840 VA Motor 2000 VA 125.00% 2500 VA Total Conn. Load:30340 VA HVAC 6000 VA 100.00% 6000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:124 A 119 A 33 A Total Load:13540 VA 12900 VA 3900 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 Receptacle 20 A 1 180... 1000... -- -- -- 16 13 -- -- -- 1000... 1000... 2 20 A DCU-06-02 14 11 DCU-XX-01 20 A 2 1000... 1000... -- -- -- 12 9 Receptacle 20 A 1 720... 1000... 2 20 A DCU-XX-01 10 7 Receptacle 20 A 1 540... 1000... -- -- -- 8 5 Receptacle 20 A 1 900... 1000... 2 20 A DCU-07-03 6 3 -- -- -- 5000... 5000... -- -- -- 4 1 CAR CHARGING 20 A 2 5000... 5000... 2 20 A CAR CHARGING 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:225 A Mounting:Surface Wires:4 MCB Rating:150 A Supply From:T-6L1 Phases:3 Mains Type:MCB Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 6L1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 1184 VA 125.00% 1480 VA Total Est. Demand:16 A Lighting STAIRWELL 4512 VA 125.00% 5640 VA Total Conn.:13 A Other 504 VA 100.00% 504 VA Total Est. Demand:13560 VA Lighting - Dwelling Unit 800 VA 100.00% 800 VA Total Conn. Load:11104 VA Lighting 4128 VA 125.00% 5160 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:19 A 9 A 13 A Total Load:5206 VA 2443 VA 3456 VA 47 ---- --3456...48 45 ---- --2443...46 43 E9H1 225 A 3 3606...44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 Lighting GARAGE 20 A 1 640... 960... 1 20 A Lighting 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:225 A Supply From:E3H1 Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: E6H1 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:54 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−08 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 736 VA 125.00% 920 VA Motor-RESIDENTIAL ELEVATOR 500 VA 100.00% 500 VA Receptacle 3780 VA 100.00% 3780 VA Power 20000 VA 100.00% 20000 VA Other 0 VA 0.00% 0 VA Total Est. Demand:85 A Motor 4000 VA 125.00% 5000 VA Total Conn.:83 A Lighting 832 VA 125.00% 1040 VA Total Est. Demand:70345 VA Heating 35200 VA 100.00% 35200 VA Total Conn. Load:68971 VA HVAC 4000 VA 100.00% 4000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:103 A 95 A 60 A Total Load:27254 VA 25127 VA 16593 VA 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 Lighting GARAGE 20 A 1 640... 864... 1 20 A Lighting 10 7 Lighting GARAGE 20 A 1 64 VA 1333... -- -- -- 8 5 -- -- -- 1526... 1333... -- -- -- 6 3 -- -- -- 2236... 1333... 3 20 A F-08-01 4 1 T-1L8 80 A 3 2286... 3000... 1 20 A EH-01 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:6H1 Phases:3 Mains Type:MLO Location:Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 8H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Motor-RESIDENTIAL ELEVATOR 500 VA 100.00% 500 VA Total Est. Demand:168 A Receptacle 3780 VA 100.00% 3780 VA Total Conn.:168 A Power 20000 VA 100.00% 20000 VA Total Est. Demand:60480 VA Heating 32200 VA 100.00% 32200 VA Total Conn. Load:60480 VA HVAC 4000 VA 100.00% 4000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:200 A 195 A 127 A Total Load:22860 VA 22360 VA 15260 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 -- -- -- 1000...44 41 DCU-XX-01 20 A 2 1000... 900... 1 20 A Receptacle 42 39 -- -- -- 5000... 720... 1 20 A Receptacle 40 37 CAR CHARGING 20 A 2 5000... 860... 1 20 A Receptacle 38 35 -- -- -- 1000... 3100... -- -- -- 36 33 EH-03 20 A 2 1000... 3100... 2 20 A WH-3 34 31 -- -- -- 1000... 1000... -- -- -- 32 29 EH-03 20 A 2 1000... 1000... 2 20 A EH-03 30 27 -- -- -- 1000... 1000... -- -- -- 28 25 EH-03 20 A 2 1000... 1000... 2 20 A EH-03 26 23 -- -- -- 1000... 0 VA -- -- -- 24 21 EH-03 20 A 2 1000... 0 VA 2 20 A DCU-07-02 22 19 -- -- -- 1000... 1000... -- -- -- 20 17 EH-03 20 A 2 1000... 1000... 2 20 A EH-03 18 15 -- -- -- 1000... 1000... -- -- -- 16 13 EH-03 20 A 2 1000... 1000... 2 20 A EH-03 14 11 -- -- -- 1000... 1260... 1 20 A Receptacle 12 9 EH-03 20 A 2 1000... 540... 1 20 A Receptacle 10 7 -- -- -- 1000... 1000... -- -- -- 8 5 DCU-XX-01 20 A 2 1000... 1000... 2 20 A EH-03 6 3 -- -- -- 1000... 5000... -- -- -- 4 1 EH-03 20 A 2 1000... 5000... 2 20 A CAR CHARGING 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:225 A Mounting:Surface Wires:4 MCB Rating:150 A Supply From:T-8L1 Phases:3 Mains Type:MCB Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 8L1 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:56 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−09 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Receptacle 4320 VA 100.00% 4320 VA Other 196 VA 100.00% 196 VA Total Est. Demand:79 A Motor 22600 VA 119.25% 26950 VA Total Conn.:73 A Lighting - Dwelling Unit 880 VA 100.00% 880 VA Total Est. Demand:65455 VA Lighting 128 VA 125.00% 160 VA Total Conn. Load:61074 VA Heating 33000 VA 100.00% 33000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:74 A 68 A 81 A Total Load:20151 VA 18764 VA 22160 VA 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 Lighting - Dwelling Unit 20 A 1 240...16 13 Lighting 20 A 1 448... 320... 1 20 A Lighting - Dwelling Unit 14 11 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 12 9 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 10 7 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 8 5 -- -- -- 6360... 5800... -- -- -- 6 3 -- -- -- 2736... 5800... -- -- -- 4 1 T-1L9 250 A 3 3620... 5800... 3 30 A SCU-XX-01 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:5000A BUS Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 908 Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 9H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Total Est. Demand:38 A Receptacle 4320 VA 100.00% 4320 VA Total Conn.:35 A Other 196 VA 100.00% 196 VA Total Est. Demand:13716 VA Motor 5200 VA 119.23% 6200 VA Total Conn. Load:12716 VA Heating 3000 VA 100.00% 3000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:31 A 23 A 54 A Total Load:3620 VA 2736 VA 6360 VA 89 -- -- -- 180...90 87 -- -- -- 180...88 85 9L1B 400 A 3 180...86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 Other 20 A 1 56 VA 16 13 Other 20 A 1 140...14 11 F-XX-01 20 A 1 4000... 500... 1 20 A CP-0 12 9 PIU-XX-01 20 A 1 700... 360... 1 20 A Receptacle 10 7 -- -- -- 1500... 540... 1 20 A Receptacle 8 5 WH-O 20 A 2 1500... 180... 1 20 A Receptacle 6 3 Receptacle 20 A 1 360... 1080... 1 20 A Receptacle 4 1 Receptacle 20 A 1 720... 540... 1 20 A Receptacle 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:400 A Mounting:Surface Wires:4 MCB Rating:400 A Supply From:T-9L1 Phases:3 Mains Type:MCB Location:TENANT CORRIDOR 911 Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 9L1A 2. 2.. SHADED AREAS SHOWN FOR LUG LOAD VERIFICATION PURPOSED ONLY. 1. PROVIDE FEEDTHRU LUGS Notes: Total Est. Demand:1 A Total Conn.:1 A Total Est. Demand:540 VA Total Conn. Load:540 VA Receptacle 540 VA 100.00% 540 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:2 A 2 A 2 A Total Load:180 VA 180 VA 180 VA 89 -- -- -- 0 VA 90 87 -- -- -- 0 VA 88 85 1L9C 400 A 3 0 VA 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 180... 1 20 A Receptacle 6 3 180... 1 20 A Receptacle 4 1 180... 1 20 A Receptacle 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:9L1A Phases:3 Mains Type:MLO Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 9L1B 2. 2.. SHADED AREAS SHOWN FOR LUG LOAD VERIFICATION PURPOSED ONLY. 1. PROVIDE FEEDTHRU LUGS Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:0 A 0 A 0 A Total Load:0 VA 0 VA 0 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:9L1B Phases:3 Mains Type:MLO Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 9L1C 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Lighting GARAGE 576 VA 125.00% 720 VA Total Est. Demand:14 A Lighting STAIRWELL 4512 VA 125.00% 5640 VA Total Conn.:11 A Other 504 VA 100.00% 504 VA Total Est. Demand:11560 VA Lighting - Dwelling Unit 800 VA 100.00% 800 VA Total Conn. Load:9504 VA Lighting 3136 VA 125.00% 3920 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:14 A 9 A 13 A Total Load:3606 VA 2443 VA 3456 VA 47 ---- --2432...48 45 ---- --1355...46 43 E12H1 225 A 3 1785...44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 Lighting - Dwelling Unit 20 A 1 320... 160... 1 20 A Lighting - Dwelling Unit 8 5 Lighting GARAGE 20 A 1 576... 448... 1 20 A Lighting - Dwelling Unit 6 3 Lighting STAIRWELL 20 A 1 768... 320... 1 20 A Lighting 4 1 Lighting STAIRWELL 20 A 1 672... 672... 1 20 A Lighting STAIRWELL 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:225 A Supply From:E6H1 Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 908 Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: E9H1 Date Issue/Revision 05.04.18 DESIGN DEVELOPMENT 08.14.18 ISSUE FOR CONSTRUCTION PANEL SCHEDULE NOTES: 1. CONTRACTOR TO COORDINATE POWER REQUIREMENTS WITH EQUIPMENT SELECTED. 2. REFER TO MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL POWER REQUIREMENTS AND LOCATIONS FOR BUILDING MANAGEMENT SYSTEM CONTROL PANELS, VAV POWER, PIU POWER, CARBON MONOXIDE DETECTOR PANELS, ETC. CONTRACTOR SHALL PROVIDE/ALLOW FOR ADDITIONAL POWER REQUIREMENTS IN BID. 3. PROVIDE NEC REQUIRED DISCONNECTS. 4. PROVIDE VENDING MACHINES, KITCHEN EQUIPMENT, DISHWASHERS, ETC WITH GFCI BREAKERS. VERIFY EQUIPMENT TYPE AND LOCATIONS WITH ARCHITECTURAL DRAWINGS. c NORTH CAROLINA REG NO: C-2129 100 CRESCENT CENTRE PARKWAY, TUCKER, GEORGIA 30084 (770)270-1588 FAX (770)270-9588PROJECT NO: 17062 Leppard Johnson & Associates, PC SUITE 520 LLCARCHITECTUREINTERIOR DESIGNRUBIOTRAMMELLULEROYJ300 Galleria Parkway Suite 740 Atlanta, Georgia 30339770-661-1492 (phone) 770-661-1493 (fax)www.rjtplusr.comTHIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT © 2012DRAWING NO: PRINTED DATE:COMMISSION NO:ISSUED FOR CONSTRUCTION8/13/2018 11:23:58 AM C:\Users\ashley.LEPPARDJOHNSON\Documents\17062 - ELECTRICAL_v17_ashley_leppardjohnson_com.rvtE5−10 08.14.18ELECTRICAL SCHEDULES401 SOUTH GRAHAM401 SOUTH GRAHAM STREETCHARLOTTE, NORTH CAROLINA15_085 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:49 A Total Conn.:47 A Receptacle 3780 VA 100.00% 3780 VA Total Est. Demand:40605 VA Motor 5700 VA 119.74% 6825 VA Total Conn. Load:39480 VA Heating 30000 VA 100.00% 30000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:51 A 47 A 45 A Total Load:14000 VA 12900 VA 12580 VA 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 12 9 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 10 7 EH-09 20 A 1 5000... 5000... 1 20 A EH-09 8 5 -- -- -- 1080... 1500... -- -- -- 6 3 -- -- -- 1400... 1500... -- -- -- 4 1 T-10L1 250 A 3 2500... 1500... 3 20 A SCU-XX-01 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:5000A BUS Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 1008 Volts:480/277 Wye A.I.C. Rating:65,000 Branch Panel: 10H1 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFICATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS Notes: Total Est. Demand:14 A Total Conn.:14 A Total Est. Demand:5155 VA Receptacle 3780 VA 100.00% 3780 VA Total Conn. Load:4980 VA Motor 1200 VA 114.58% 1375 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:21 A 12 A 9 A Total Load:2500 VA 1400 VA 1080 VA 89 -- -- -- 0 VA 90 87 -- -- -- 0 VA 88 85 10L1B 400 A 3 0 VA 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 360... 1 20 A Receptacle 12 9 540... 1 20 A Receptacle 10 7 720... 1 20 A Receptacle 8 5 Receptacle 20 A 1 540... 180... 1 20 A Receptacle 6 3 Receptacle 20 A 1 360... 500... 1 20 A F-XX-01 4 1 Receptacle 20 A 1 1080... 700... 1 20 A PIU-XX-01 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mains Rating:400 A Mounting:Surface Wires:4 MCB Rating:400 A Supply From:T-10L1 Phases:3 Mains Type:MCB Location:TENANT CORRIDOR 1011 Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 10L1A 2. 2.. SHADED AREAS SHOWN FOR LUG LOAD VERIFICATION PURPOSED ONLY. 1. PROVIDE FEEDTHRU LUGS Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:0 A 0 A 0 A Total Load:0 VA 0 VA 0 VA 89 -- -- -- 0 VA 90 87 -- -- -- 0 VA 88 85 10L1C 400 A 3 0 VA 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:10L1A Phases:3 Mains Type:MLO Location:TENANT CORRIDOR 1011 Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 10L1B 2. 2.. SHADED AREAS SHOWN FOR LUG LOAD VERIFICATION PURPOSED ONLY. 1. PROVIDE FEEDTHRU LUGS Notes: Total Est. Demand:0 A Total Conn.:0 A Total Est. Demand:0 VA Total Conn. Load:0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:0 A 0 A 0 A Total Load:0 VA 0 VA 0 VA 89 90 87 88 85 86 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:400 A Supply From:10L1B Phases:3 Mains Type:MLO Location:TENANT CORRIDOR 1011 Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: 10L1C Date Issue/Revision 08.14.18 ISSUE FOR CONSTRUCTION 2. SHADED AREA IS SHOWN FOR LUG LOAD VERIFCATION PURPOSES ONLY. 1. PROVIDE FEED THRU LUGS. Notes: Total Est. Demand:1 A Total Conn.:1 A Total Est. Demand:210 VA Total Conn. Load:210 VA Other 210 VA 100.00% 210 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:2 A 0 A 0 A Total Load:210 VA 0 VA 0 VA 35 -- -- -- 0 VA 36 33 -- -- -- 0 VA 34 31 E14L1 100 A 3 0 VA 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 210... 1 20 A Other 2 CKT Load Name Trip Poles A B C Poles Trip Load Name CKT Enclosure:Type 1 Mounting:Surface Wires:4 Mains Rating:100 A Supply From:E1L1 Phases:3 Mains Type:MLO Location:Volts:120/208 Wye A.I.C. Rating:10,000 Branch Panel: E10L1