Loading...
HomeMy WebLinkAbout22010_Glenwood Square_EMP_20190528NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the North Carolina Brownfields Program at the direction of a Brownfields project manager. The EMP is a typical requirement of a Brownfields Agreement (BFA). Its purpose is to clarify actions to be taken during the demolition and construction at Brownfields properties in an effort to avoid delays in the event of the discovery of new contamination sources or other environmental conditions. The EMP provides a means to document redevelopment plans and environmental data for each applicable environmental medium to inform regulatory -compliant decision -making at the site. As much detail as possible should be included in the EMP, including contingency planning for unknowns. Consult your project manager if you have questions. Prospective Developers and/or their consultants must complete and submit this form and all pertinent attachments, see checklist below, to their Brownfields project manager prior to any earthmoving or other development -related activities that have the potential to disturb soil at the Brownfields Property, including demolition. For the resultant EMP to be valid for use, it must be completed, reviewed by the program, signed by all parties working on the project, and approved by the Brownfields project manager. Failure to comply with the requirements of the EMP could jeopardize project eligibility, or in the event of a completed agreement, be cause for a reopener So that the EMP provides value in protecting brownfields eligibility and public health, the preparer shall ensure that the following steps have been completed prior to submitting the EMP for review. Any EMP prepared without completing these steps is premature. ® Site sampling and assessment that meets Brownfields' objectives is complete and has been reviewed and approved by the Brownfields Project Manager. ® Specific redevelopment plans, even if conceptual, have been developed for the project, submitted and reviewed by the Brownfields Project Manager. EMP Version 2, June 2018 Please submit, along with the completed EMP form, the following attachments, as relevant and applicable to the proposed redevelopment: ® A set of redevelopment plans, including architectural/engineering plans, if available; if not conceptual plans may suffice if updated when detailed plans are drafted. ® A figure overlaying redevelopment plans on a map of the extent of contamination for each media. ® Site grading plans that include a cut and fill analysis. ❑ A figure showing the proposed location and depth of impacted soil that would remain on site after construction grading. ❑ Any necessary permits for redevelopment (i.e. demolition, etc.). ® A detailed construction schedule that includes timing and phases of construction. ® Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas, etc.) applicable to the proposed redevelopment. ® Figures with the sampling locations and contamination extents for each impacted media applicable to the proposed redevelopment. ❑ A full final grade sampling and analysis plan, if the redevelopment plan is final. ❑ If known, information about each proposed potential borrow soil source, such as aerial photos, historic site maps, historic Sanborn maps, a site history, necessary for brownfields approval. ❑ Information and, analytical data if required, for quarries, or other borrow sources, detailing the type of material proposed for importation to the Brownfields Property. ❑ A work plan for the sampling and analysis of soil to be brought onto the Brownfields Property. Refer to Issue Resolution 15 in Brownfields Program Guidelines. ❑ A map of the Brownfields Property showing the location of soils proposed for export and sampling data from those areas. ❑ If a Vapor Mitigation System is required by the Brownfields Program, the Vapor Intrusion Mitigation System (VIMS) plan will be signed and sealed by a NC Professional Engineer. The VIMS Plan may also be submitted under separate cover. EMP Version 2, June 2018 Date: 1/24/2019 GENERAL INFORMATION Revision Date (if applicable): 4/26/2019 Brownfields Assigned Project Name: Glenwood Square Brownfields Project Number: 22010-18-092 Brownfields Property Address: 615, 621, 623, 701, and 709 Hillsborough Street; 11 South Boylan Avenue, Raleigh, Wake County Brownfields Property Area (acres): 1.99 Is Brownfields Property Subject to RCRA Permit? ....................... ❑ Yes ® No If yes enter Permit No.: Click or tap here to enter text. Is Brownfields Property Subject to a Solid Waste Permit ............ ❑ Yes ® No If yes, enter Permit No.: Click or tap here to enter text. COMMUNICATIONS A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the EMP shall be maintained at the Brownfields Property during redevelopment activities. NOTE, THE EMP DOES NOT TAKE THE PLACE OF A SITE -SPECIFIC HEALTH AND SAFETY PLAN. Prospective Developer (PD): Glenwood Two LLC Contact Person: Ryan Blair Phone Numbers: Office: 410-769-6139 Mobile: 443-900-2158 Email: rblair@hpimd.com Contractor for PD: Whiting Turner Construction Company Contact Person: Brian Hale Phone Numbers: Office: (919) 256-6460 Mobile: (954) 818-6573 Email: brian.hale@whiting-turner.com Environmental Consultant: GTA Associates Inc. Contact Person: Jeffrey Mutter Phone Numbers: Office: 410-792-9446 Mobile: 410-984-9476 Email: jmutter@gtaeng.com Brownfields Program Project Manager: Kelly Johnson Phone Numbers: Office: Raleigh Mobile: 919.707.8279 Email: Kelly.johnson@ncdenr.gov 3 EMP Version 2, June 2018 Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch, Hazardous Waste, Solid Waste): _iicK or iap nere io enier iexi. NOTIFICATIONS TO THE BROWNFIELDS PROGRAM Written advance Notification Times to Brownfields Project Manager: Check each box to accept minimum advance notice periods (in calendar days) for each type of onsitetask: On -site assessment or remedial activities: .................................................... 10 days Prior Construction or grading start: .......................................................................... 10 days Prior Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously unknown contamination: ................................................................................ Within 48 hours Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in area of contamination, ventilation of work zones): ................................... Within 48 hours Installation of mitigation systems: ................................................................ 10 days Prior IK Other notifications as required by local, state or federal agencies toimplement redevelopment activities: (as applicable): ................................................................................. Within 30 days REDEVELOPMENT PLANS 1) Type of Redevelopment (check all that apply): ❑Residential ❑Recreational El Institutional ®Commercial ®Office ®Retail ❑ Industrial ®Other specify: Parking, Restaurant 2) Check the following activities that will be conducted prior to commencing earth -moving activities at the site: ® Review of historic maps (Sanborn Maps, facility maps) ® Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc. ® Interviews with employees/former employees/facility managers/neighbors 3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if detailed plans are not available. EMP review without such information would be premature): Provide brief summary of redevelopment plans, including demolition, removal of building slabs/pavement, grading plans and planned construction of new structures: EMP Version 2, June 2018 The development will consists of a 10 story office/retail building, a 635 space open parking garage, and two single story retail buildings. 4) Do plans include demolition of structure(s)?: ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements, including without limitation those related to lead and asbestos abatement that are administered by the Health Hazards Control Unit within the Division of Public Health of the North Carolina Department of Health and Human Services. If available, please provide a copy of your demolition permit. 5) Are sediment and erosion control measures required by federal, state, or local regulations? ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements. If soil disturbance is necessary to install sediment and erosion control measures, they may not begin until this EMP is approved. 6) Which category of risk -based screening level is used or is anticipated to be specified in the Brownfields Agreement? Note: If children frequent the property, residential screening levels shall be cited in the Brownfields Agreement for comparison purposes. ❑ Residential ® Non -Residential or Industrial/Commercial 7) Schedule for Redevelopment (attach construction schedule): a) Construction start date: 9/30/2019 b) Anticipated duration (specify activities during each phase): Office/Retail/Courtyard: Demo/Sitework Start 8/15/2019 Foundations Start 11/1/2019 Core & Shell Start 2/5/2020 Core & Shell Completion 12/15/2020 Prelease Up -Fit Completion 9/1/2020 Garage: Demo Sitework Start 8/15/2019 Garage Foundations Start 1/21/2020 Garage Completion 9/1/2020 c) Additional phases planned? ❑ Yes ❑ No If yes, specify the start date and/or activities if known: Start Date: N/A Planned Activity: No additional phases are planned. Document will not allow "No" to be checked above. 5 EMP Version 2, June 2018 Start Date: lick or tap to enter a date. Planned Activity: LACK or iap nere to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. d) Provide the planned date of occupancy for new buildings: 9/1/2020 CONTAMINATED MEDIA 1) Contaminated Media on the Brownfields Property Part 1. Soil: .............................................................. ® Yes ❑ No ❑ Suspected Part 2. Groundwater: ............................................ ® Yes ❑ No ❑ Suspected Part 3. Surface Water: .......................................... ❑ Yes © No ❑ Suspected Part 4. Sediment: ................................................... ❑ Yes ® No ❑ Suspected Part S. Soil Vapor: .................................................. ❑ Yes ® No ❑ Suspected Part 6. Sub -Slab Soil Vapor: .................................. ❑ Yes ® No ❑ Suspected Part 7. Indoor Air: ................................................... ❑ Yes ® No ❑ Suspected 2) For the Area of Proposed Redevelopment on the Brownfields Property, attach tabulated data summaries for each impacted media and figure(s) with sample locations. PART 1. Soil — Please fill out the information below, using detailed site plans, if available, or estimate using known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new construction onto figure showing contaminated soil and groundwater locations. 1) Known or suspected contaminants in soil (list general groups of contaminants): One VOC , one SVOC, and no metals detected above the Commercial MSCCs. However, there are several geophysical anomalies that are likely associated with underground storage tanks (USTs) on the subject property. During the removal of any potential USTs we may encounter petroleum impacted soil. If so, that soil will be handled and disposed of in coordination with DEQ. 2) Depth of known or suspected contaminants (feet): 10-20' 3) Area of soil disturbed by redevelopment (square feet): 70,000 6 EMP Version 2, June 2018 4) Depths of soil to be excavated (feet): 4.5 5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan): 2,266 (see Attachment B) 6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants: 200 7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: 200 Part 1.A. MANAGING ONSITE SOIL If soil is anticipated to be excavated fromthe Brownfield Property, relocated on the Brownfields Property, or otherwise disturbed during site grading or other redevelopment activities, please provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are acceptable, if only preliminarydata available). 1) HAZARDOUS WASTE DETERMINATION: a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous Waste Section under 40 CFR Part 261.31-261.35?....................................... ❑Yes ®No ❑ If yes, explain why below, including the level of knowledge regarding processes generating the waste (include pertinent analytical results as needed). UICK or tap here to enter text. ❑ If yes, do the soils exceed the "Contained -Out" levels in Attachment 1 of the North Carolina Contained -In Policy? ................................................. ❑ Yes ❑ No b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE CONTAINED -OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED -IN POLICYTHE SOIL MAY NOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. c) Does the soil contain a CHARACTERISTIC WASTE? .................................... ❑ Yes ® No ❑ If yes, mark reason(s) why below (and include pertinent analytical results). ❑ Ignitability Click or tap here to enter text. ❑ Corrosivity Click or tap here to enter text. ❑ Reactivity Click or tap here to enter text. ❑ Toxicity Click or tap here to enter text. ❑ TCLP results Click or tap here to enter text. 7 EMP Version 2, June 2018 ❑ Rule of 20 results (20 times total analytical results for an individual hazardous constituent on TCLP list cannot, by test method, exceed regulatory TCLP standard) -lick tap here to enter t­ ® If no, explain rationale: Characteristic soils are not expected to be encountered. d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAYNOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. 2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in place with low permeability barrier, removed to onsite location and capped, removed offsite): ❑ Preliminary Health -Based Residential SRGs ® Preliminary Health -Based Industrial/Commercial SRGs ❑ Division of Waste Management Risk Calculator (For Brownfields Properties Only) ❑ Site -specific risk -based cleanup level. Please provide details of methods used for determination/explanation. Click or tap here to enter text. Additional comments: Click or tap here to enter text. 3) If known impacted soil is proposed to be reused within the Brownfields Property Boundary, please check the measures that will be utilized to ensure safe placement and documentation of same. Please attach a proposed location diagram/site map. ❑ Provide documentation of analytical report(s) to Brownfields Project Manager ❑ Provide documentation of final location, thickness and depth of relocated soil on site map to Brownfields Project Manager once known ❑ Geotextile to mark depth of fill material. Provide description of material: --­ -1----+oenter - ❑ Manage soil under impervious cap ❑ or clean fill ❑ ❑ Describe cap or fill: - - tap here to ent, - ❑ Confer with NC BF Project Manager if Brownfield Plat must be revised (or re -recorded if actions are Post -Recordation). ❑ GPS the location and provide site map with final location. EMP Version 2, June 2018 ❑ Other. Please provide a description of the measure: Click or tap here to enter te> 4) Please describe the following action(s) to be taken during and following excavation and management of site soils: Management of fugitive dust from site ® Yes, describe the method will include: Soil will be dampened upon excavation in the vicinity of known contamination to avoid fugitive dust. ❑ No, explain rationale: -hA/ —+An here to enter+ext. Field Screenine of site soil ® Yes, describe the field screening method, frequency of field screening, person conducting field screening: Soil excavated from areas of known contamination will be screened using a field device as well as visual and olfactory perception to assess the potential existence of contamination. Aside from known areas of contamination, excavated soils will be screened for odor and discoloration possibly indicative of petroleum contamination during redevelopment grading and excavation. If evidence of possible petroleum contamination is discovered then the soil will be screened with an OVA and/or PID and temporarily stockpiled. If necessary, grab samples will be collected and sent to the laboratory for analyses using EPA Methods 8260 and 8270, and for the EPA RCRA metals. In the area east of South Boylan Avenue, where PCE was detected in soil vapor samples, environmental personnel will be present during excavation to screen and segregate (if necessary) excavated soils. ❑ No, explain rationale: Clirl� nr ter) here — enter text. Soil Sample Collection ® Yes, describe the sampling method (e.g., in -situ grab, composite, stockpile, etc.): Based on soil quantity the necessary number of composite soil samples will be collected to meet the requirements of the facility which will be receiving the material. ❑ No, explain rationale: Click or tap here to enter text. If soil samples are collected for analysis, please check the applicable chemical analytes: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 EMP Version 2, June 2018 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): USEPA Method 6020. If elevated total chromium is detected that sample(s) will be speciated. ❑ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter tc ® PCBs: Specify Analytical Method Number(s): USEPA Method 8082 ❑ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Specify Analytical Method Number(s): Click or tap here to enter text. ® Check to confirm that stockpiling of known or suspected impacted soils will be conducted in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion control, prohibiting contact between surface water/precipitation and contaminated soil, and preventing contaminated runoff. Explain any variances or provide additional details as needed: Excavated soils will be directly loaded when possible to avoid the requirement of stockpiling ® Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or permanent hardscape). Select chemical analyses for final grade samples with check boxes below (Check all thatapply): ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Method 6020; if elevated total chromium is detected, that sample(s) will be speciated, ❑ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ❑ PCBs: Specify Analytical Method Number(s): ❑ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Click or tap here to enter text. Please provide a scope of work for final grade sampling, including a diagram of soil sampling locations, number of samples to be collected, and brief sampling methodology. Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs which should be taken from 1-2 ft below ground surface. Alternatively, a work plan for 10 EMP Version 2, June 2018 final grade sampling may be submitted under separate cover. To be submitted when grading plan has been finalized. ❑ If final grade sampling was NOT selected please explain rationale: Click or tap here to enter t(,--- Part 1.13. IMPORTED FILL SOIL NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL FROM THE BROWNFIELDS PROGRAM. According to the Brownfields IR 15, "Documenting imported soil (by sampling, analysis, and reporting in accordance with review and written approval in advance by the Brownfields Program), will safeguard the liability protections provided by the brownfields agreement and is in the best interest of the prospective developer/property owner." Requirements for importing fill: 1) Will fill soil be imported to the site? ................................................ ® Yes ❑ No ❑ Unknown 2) If yes, what is the estimated volume of fill soil to be imported? 5,700 3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range of depths, please list the range.) 0-9 ft 4) Provide the source of fill, including: location, site history, nearby environmental concerns, etc. Attach aerial photos, maps, historic Sanborn maps and a borrow source site history: Source is to be determined; however, previous work utilized Wake Stone Quarry in Knightvale, NC, and that is the likely source for this project. 5) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide a plan to analyze fill soil to demonstrate that it meets acceptable standards applicable to the site and can be approved for use atthe Brownfields property. Fill material will be obtained from an NCDEQ-approved quarry, as noted in #4 above. 6) Please check the applicable chemical analytes for fill soil samples. (Check all that apply): © Volatile organic compounds (VOCs) by EPA Method 8260 © Semi -volatile organic compounds (SVOCs) by EPA Method 8270 © Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Method 6020; if elevated total chromium is detected, that sample(s) will be speciated for hexavalent chromium. 11 EMP Version 2, June 2018 ❑ Pesticides: Specify Analytical Method Number(s): ❑ PCBs: Specify Analytical Method Number(s): I, LICK or iap nere io enter iea. ❑ Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Click or tap here to enter text. 7) The scope of work for import fill sampling may be provided below or in a Work Plan submitted separately for DEQ review and approval. Attach specific location maps for in -situ borrow sites. If using a quarry, provide information on the type of material to be brought onto the Brownfields Property. A fill characterization plan will be submitted for DEQ review and approval. Part 1.C. EXPORTED SOIL NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE BROWNFIELDS PROGRAM. FAILURE TO OBTAIN APPROVAL MAY VIOLATE A BROWNFIELDS AGREEMENT CAUSING A REOPENER OR JEOPARDIZING ELIGIBILITY IN THE PROGRAM, ENDANGERING LIABILITY PROTECTIONS AND MAKING SAID ACTION POSSIBLY SUBJECT TO ENFORCEMENT. JUSTIFICATIONS PROVIDED BELOW MUST BE APPROVED BY THE PROGRAM IN WRITING PRIOR TO COMPLETING TRANSPORT ACTIVITIES. Please refer to Brownfields IR 15 for additional details. 1) If export from a Brownfields Property is anticipated, please provide details regarding the proposed export actions. Volume of exported soil, depths, location from which soil will be excavated on site, related sampling results, etc. Provide a site map with locations of export and sampling results included. Soil to be disposed off -site (if any) will be characterized in accordance with the requirements of the disposal facility. 2) To what type of facility will the export Brownfields soil be sent? ❑ Subtitle D/Municipal Solid Waste Landfill (analytical program to be determined by landfill) ❑ Permitted but Unlined Landfill (i.e. LCID, C&D, etc.) Analytical program to be determined by the accepting Landfill; ® Landfarm or other treatment facility ❑ Use as fill at another suitable Brownfields Property — determination that a site is suitable will require, at a minimum, that similar concentrations of the same or similar contaminants already exist at both sites, use of impacted soil will not increase the potential for risk to human health and the environment at the receiving Brownfields property, and thata record of the acceptance of such soil from the property owner of the receiving site is provided to Brownfields. Please provide additional details below. 12 EMP Version 2, June 2018 ❑ Use as Beneficial Fill off -site at a non-Brownfields Property - Please provide documentation of approval from the property owner for receipt of fill material. This will also require approval by the DEQ Solid Waste Section. Additional information is provided in IR 15. Please provide additional details below. 3) Additional Details: (if transfer of soil to another property is requested above, please provide details related to the proposed plans). Soil disposal facility is to be determined; however, soil from the Glenwood One project was disposed at Soilworks, Inc. in Selma, NC, and this facility will likely be used for this project. Part I.D. MANAGEMENT OF UTILITY TRENCHES ❑ Install liner between native impacted soils and base of utility trench before filling with clean fill (Preferred) ® Last out, first in principle for impacted soils (if soil can safely be reused onsite and is not hazardous waste), i.e., impacted soils are placed back at approximately the depths they were removed from such that impacted soil is not placed at a greater depth than the original depth from which it was excavated. ❑ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or degradation of conduit materials due to direct impact with contaminants? ❑ If yes, provide specifications on barrier materials: Click or tap here to enter text ❑ If no, include rationale here: Click or tap here to enter text. Other comments regarding managing impacted soil in utility trenches: Click or tap here to e­_. ___ PART 2. GROUNDWATER — Please fill out the information below. 1) What is the depth to groundwater at the Brownfields Property? Approximately 24.23 to 29.64 feet below ground surface. 2) Is groundwater known to be contaminated by ❑onsite ❑offsite ®both or ❑unknown sources? Describe source(s): On -site: Former gasoline stations at 623 and 701 Hillsborough Street; off -site: former gasoline station located at 630 Hillsborough Street, adjacently north of the site. 3) What is the direction of groundwater flow at the Brownfields Property? Approximately east to southeast 13 EMP Version 2, June 2018 4) Will groundwater likely be encountered during planned redevelopment activities? El Yes ®No If yes, describe these activities: Regardless of the answer; in the event that contaminated groundwater is encountered during redevelopment activities (even if no is checked above), list activities for contingent management of groundwater (e.g., dewateringof groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or sampling procedures). Should groundwater be encountered during excavations or grading, depending on the quantity, the water will be containerized and disposed off -site or treated and disposed on -site or to storm sewer. If dewatering is required, such activities will be coordinated with the City of Raleigh. 5) Are monitoring wells currently present on the Brownfields Property? ................. ❑X Yes ❑ No If yes, are any monitoring wells routinely monitored through DEQ or other agencies?.................................................................................................................. ❑Yes ®No 6) Please check methods to be utilized in the management of known and previously unidentified wells. ® Abandonment of site monitoring wells in accordance with all applicable regulations. It is the Brownfields Program's intent to allow proper abandonment of well(s) as specified in the Brownfields Agreement, except if required for active monitoring through another section of DEQ or the EPA. ❑ Location of existing monitoring wells marked ❑ Existing monitoring wells protected from disturbance ❑ Newly identified monitoring wells will be marked and protected from further disturbance until notification to DEQ Brownfields can be made and approval for abandonment is given. 7) Please provide additional details as needed: Click or tap here to enter text. Please note, disturbance of existing site monitoring wells without approval by DEQ is not permissible. If monitoring wells are damaged and/or destroyed, DEQ may require that the PD be resaonsible for replacement of the well. PART 3. SURFACE WATER -Please fill out the information below. 1) Is surface water present at the property? ❑ Yes ® No 2) Attach a map showing the location of surface water at the Brownfields Property. 14 EMP Version 2, June 2018 3) Is surface water at the property known to be contaminated? ❑ Yes ® No 4) Will workers or the public be in contact with surface water during planned redevelopment activities? ❑ Yes ® No 5) In the event that contaminated surface water is encountered during redevelopment activities, or clean surface water enters open excavations, list activities for management of such events (e.g. flooding, contaminated surface water run-off, stormwater impacts): Click or tap here to enter tex PART 4. SEDIMENT — Please fill out the information below. 1) Are sediment sources present on the property? ❑ Yes ® No 2) If yes, is sediment at the property known to be contaminated: ❑ Yes ® No 3) Will workers or the public be in contact with sediment during planned redevelopment activities? ❑ Yes ® No 4) Attach a map showing location of known contaminated sediment at theproperty. 5) In the event that contaminated sediment is encountered during redevelopment activities, list activities for management of such events (stream bed disturbance): _.. _.. _. -IJ I ICI C - C. L-I -AL PART 5. SOIL VAPOR — Please fill out the information below. 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the following vapor intrusion screening levels (current version) in the following media: IHSB Residential Screening Levels: Soil Vapor: ........... ❑ Yes ❑ No ❑ Unknown Groundwater:..... El Yes ❑ No ❑ Unknown IHSB Industrial/Commercial Screening Levels: Soil Vapor: ........... ❑ Yes ® No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown 2) Attach a map showing the locations of soil vapor contaminants that exceed site screening levels. 3) If applicable, at what depth(s) is soil vapor known to be contaminated? PCE and TCE were detected in one soil vapor sample collected east of South Boylan Avenue, at concentrations well below the soil vapor screening levels. Limited soil and groundwater sampling did 15 EMP Version 2, June 2018 not detect either compound. 4) Will workers encounter contaminated soil vapor during planned redevelopment activities? ❑ Yes ® No ❑ Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities (trenches, manways, basements or other subsurface work,) list activities for management of such contact: Screening using field instruments, ventilation of affected area(s) using appropriate equipment as determined by field screening results. PART 6. SUB -SLAB SOIL VAPOR — Please fill out the information below if existing buildings or foundations will be retained in the redevelopment. 1) Are sub -slab soil vapor data available for the Brownfields Property? ® Yes ❑ No ❑ Unknown 2) If data indicate that sub -slab soil vapor concentrations exceed screening levels, attach a map showing the location of these exceedances. 3) At what depth(s) is sub -slab soil vapor known to be contaminated? ❑0-6 inches ❑Other, please describe: PCE and TCE were detected in two sub -slab soil vapor samples collected from Dram and Draught and the stereo shop east of South Boylan Avenue, at concentrations well below the soil vapor screening levels. Limited soil and groundwater sampling did not detect either compound. 4) Will workers encounter contaminated sub -slab soil vapor during planned redevelopment activities? ❑ Yes ® No ❑ Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities, list activities for management of such contact Screening using field instruments, ventilation of affected area(s) using appropriate equipment as determined by field screening results. PART 7. INDOOR AIR — Please fill out the information below. 1) Are indoor air data available for the Brownfields Property? ❑ Yes ® No ❑ Unknown 2) Attach a map showing the location(s) where indoor air contaminants exceed site screening levels. 3) If the structures where indoor air has been documented to exceed risk -based screening levels will not be demolished as part of redevelopment activities, will workers encounter contaminated indoor air during planned redevelopment activities? ❑ Yes ❑ No ❑ Unknown 4) In the event that contaminated indoor air is encountered during redevelopment activities, list 16 EMP Version 2, June 2018 activities for management of such contact: Screening using field instruments, ventilation of affected area(s) using appropriate equipment as determined by field screening results. VAPOR INTRUSION MITIGATION SYSTEM — Please fill out the information below. Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property? ❑ Yes ® No ❑ Unknown If yes, ❑ VIMS Plan Attached or ❑ VIMS Plan to be submitted separately If submitted separately provide date: Click or tap here to enter tex VIMS Plan shall be signed and sealed by a NC Professional Engineer If no, please provide a brief rationale as to why no vapor mitigation plan is warranted: Indoor air is not considered to be a risk at this site. CONTINGENCY PLAN — encountering unknown tanks, drums, or other waste materials In this section please provide actions that will be taken to identify or manage unknown potential new sources of contamination. During redevelopment activities, it is not uncommon that unknown tanks, drums, fuel lines, landfills, orother waste materials are encountered. Notification to DEQ Brownfields Project Manager, UST Section, Fire Department, and/or other officials, as necessary and appropriate, is required when new potential source(s) of contamination are discovered. These Notification Requirements were outlined on Page 1 of this EMP. Should potentially impacted materials be identified that are inconsistent with known site impacts, the DEQ Brownfields Project Manager will be notified and a sampling plan will be prepared based on the EMP requirements and site -specific factors. Samples will generally be collected to document the location of the potential impacts. Check the following chemical analysis that are to be conducted on newly identified releases: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver) USEPA Method 6020; if elevated concentrations of chromium are detected, that sample(s) will be speciated for hexavalent chromium. 17 EMP Version 2, June 2018 ❑ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ❑ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ❑ Other Constituents & Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.) Please note, if field observations indicate the need for additional analyses, they should be conducted, even if not listed here. -I I% -I\ VI LCIP IICIC LV MILM ICA. Please provide details on the proposed methods of managing the following commonly encountered issues during redevelopment of Brownfields Properties. Click or tap here to enter text. Underground Storage Tanks: Notify NCDEQ Brownfields Program. Evaluate UST condition and remove in coordination with DEQ. Sub -Grade Feature/Pit: Notify NCDEQ Brownfields Program. Evaluate feature or pit to determine prior use and potential for contamination. If the potential for contamination is present, assess and remediate as appropriate for the contamination identified. Buried Waste Material: Notify NCDEQ Brownfields Program. Evaluate the waste material for potential for contamination. If the potential for contamination is present, assess and remediate as appropriate for the contamination identified. Re -Use of Impacted Soils On -Site: Excavated soils planned for re -use on site will be field -screened prior to re -use. Soils exhibiting field indicators of potential impact will be utilized beneath landscaped areas, parking areas, or the open parking deck, and not beneath enclosed spaces such as elevator shafts, stairwells, and retail spaces. If unknown, impacted soil is identified on -site, management on -site can be considered after the project team provides the necessary information, outlined in Part 1.A. Item 11, for Brownfields Project Manager approval prior to final placement on -site. If other potential contingency plans are pertinent, please provide other details or scenarios as needed below: Click or tap here to enter text. 18 EMP Version 2, June 2018 POST -REDEVELOPMENT REPORTING ® Check this box to acknowledge that a Redevelopment Summary Report will be required for the project. If the project duration is longer than one year, an annual update is required and will be due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of this EMP (as agreed upon with the Project Manager). These reports will be required for as long as physical redevelopment of the Brownfields Property continues, except that the final Redevelopment Summary Report will be submitted within 90 days after completion of redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary Report is anticipated to be submitted on 3/15/2020 The Redevelopment Summary Report shall include environment -related activities since the last report, with a summary and drawings, that describes: 1. actions taken on the Brownfields Property; 2. soil grading and cut and fill actions; 3. methodology(ies) employed for field screening, sampling and laboratory analysis of environmental media; 4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and ultimate disposition of any soil, groundwater or other materials suspected or confirmed to be contaminated with regulated substances; and 5. removal of any contaminated soil, water or other contaminated materials (for example, concrete, demolition debris) from the Brownfields Property (copies of all legally required manifests shall be included). ❑X Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment Summary Report in compliance with the site's Brownfields Agreement. 19 EMP Version 2, June 2018 APPROVAL SIGNATURES Brownfields Project Number: 22010-18-092 Brownfields Project Name: Prospective velop Printed Na /Title/1 Two LLC Glenwood Square .Gleoid Two LLC mpany: Ryan Blair/Officer/Glenwood Cdfifultant: GTA Associates Inc. Printed Name/Title/Company: Jeffrey W. Mutter/Project Manager/GTA Associates Inc. Brownfields Project Manager:Kelly Johnson 20 EMP Version 2, June 2018 oat I Date Click orI tap to enter a date. May 9, 2019 Date Date Click or tap to enter a date. Figure 1 NCBP Diagram for Temporary- Containment of Impacted or Potentially Impacted Soil Cross -Section View Top Plastic C:ov(.x Shutting: lindorliner: 1 layer, minimum of iQ (1 I,syer, minim urn: 10 mil thick) mil thick plastic Berm (Straw hales, R%ciglit composted earth, etc.) (If plastic ` Wver used) Land Contaminated Soils Surface/ Straw Bale Berm Map View ght k7 .......... ......... . ..... ---_ F L Contanrinated Soils ■ ..._.... _.... ....... ....... ....... ....... ._...... ...» - V DO■ ❑ Plastic _ Sheeting Note Adapted from NC DEQ UST Section 'Guidelines for Ex Situ Petroleum Contaminated Soil Remediation" dated December, 1, 2013 21 EMP Version 2, June 2018 ATTACHMENT A REDEVELOPMENT PLANS BLOCK 623 HILLSBOROUGH STREET RALEIGH, NORTH CAROLINA, 27603 CONSTRUCTION DRAWINGS -PRICING SET PROJECT NUMBER: HTG-17000 CASE NUMBER: SR-59-18 TRANSACTION NUMBER: 559068 DATE: DECEMBER 151 2018 PRICING SET NOTE: 1. THIS SET IS TO BE USED FOR PRELIMINARY PRICING ONLY. 2. THE JOHN R. MCADAMS COMPANY SHALL NOT BE RESPONSIBLE FOR ANY ADDITIONAL COSTS INCURRED DUE TO CHANGES TO THIS PRELIMINARY PLAN DURING THE CONSTRUCTION DRAWING PERMIT PROCESS. 1. THE DEVELOPER ACKNOWLEDGES THAT THEY HAVE REVIEWED AND ARE IN COMPLIANCE WITH THE REQUIREMENTS SET FORTH IN THE SOLID WASTE DESIGN MANUAL. 2. THE SOLID WASTE REMOVAL FOR THIS PROJECT WILL BE HANDLED BY A PRIVATE SERVICE (SEE SITE PLAN SHEET C-6). 3. REFUSE WILL BE COLLECTED IN CENTRAL COMPACTOR AND/OR DUMPSTERS AND RECYCLING AREAS WITHIN THE SITE. 1. WITHIN THE AREA OF A DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMING OR PARKED VEHICLES BETWEEN THE HEIGHTS OF TWENTY-FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB ELEVATION OR THE NEAREST TRAVELED WAY, IF NO CURBING EXISTS. 2. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS -OF -WAYS, NOT INCLUDING AN ALLEY. VICINITY MAP Know what's below. Call before you dig. SHEET INDEX C-1 EXISTING CONDITIONS C-2 PROJECT NOTES C-3 DEMOLITION PLAN C-4 SITE PLAN C-5 GRADING PLAN C-6 UTILITY PLAN EC-1 EROSION CONTROL PLAN - STAGE 1 EC-2 EROSION CONTROL PLAN - STAGE 2 EC-3 EROSION CONTROL PLAN - STAGE 3 EC-4 NPDES EROSION CONTROL PLAN EC-5 EROSION CONTROL DETAILS EC-6 EROSION CONTROL DETAILS LS-1 LANDSCAPE PLAN (BY SURFACE) LS-2 LANDSCAPE DETAILS (BY SURFACE) D-1 SITE DETAILS D-2 SITE DETAILS D-3 WATER DETAILS D-4 SANITARY SEWER DETAILS D-5 STORM DRAINAGE DETAILS D-6 STORM DRAINAGE DETAILS SW-1 STORMWATER CONTROL MEASURE DETAILS BUILDING ELEVATIONS (BYGENSLER) A0.01 ACCESSORY STRUCTURE SOUTH BLDG - ZONING ELEVATIONS A0.02 ACCESSORY STRUCTURE NORTH BLDG - ZONING ELEVATIONS A0.11 MIXED USE BUILDING ELEVATION - NORTH (HILLSBOROUGH STREET) A0.12 MIXED USE BUILDING ELEVATION - WEST (BOYLAN AVENUE) A0.13 MIXED USE BUILDING ELEVATION - SOUTH (MORGAN STREET) A0.14 MIXED USE BUILDING ELEVATION - EAST (COURTYARD) A0.15 MIXED USE BUILDING ROOF PLAN NOTE: NO TREE CONSERVATION PLAN REQUIRED DUE TO PROPOSED SITE AREA BEING LESS THAN 2.00 ACRES. UDO 4.7.4.11 ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS AND DETAILS. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, INC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CONTACT RICK SLATER slater@mcadamsco.com PHONE: 919. 361. 5000 CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 a r: HERITAGE PROPERTIES, INC PROJECT DIRECTORY DEVELOPER HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 STRUCTURAL ENGINEER LYNCH MYKINS STRUCTURAL ENGINEERS, P.C. 415 HILLSBOROUGH STREET, SUITE 101 RALEIGH, NORTH CAROLINA, 27603 PHONE: 919. 809. 8948 GEOTECHNICAL ENGINEER GTA ASSOCIATES, INC. 5605 CHAPEL HILL ROAD, SUITE 112 RALEIGH, NORTH CAROLINA, 27607 PHONE: 984. 200. 2104 ARCHITECT GENSLER 530 HILLSBOROUGH STREET RALEIGH, NORTH CAROLINA, 27603 PHONE: 919. 239. 7838 LANDSCAPE ARCHITECT SURFACE 678 215 MORRIS STREET, SUITE 150 DURHAM, NORTH CAROLINA, 27701 PHONE: 919. 419. 1199 �``��N,►CA ►� R •FES 0 •'�- R, 09 - �GINE. • S. S\-",%O,* REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION CONSTRUCTION DRAWINGS - PRICING SET FOR: N.T.S. PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION BLOCK 83 RALEIGH, NORTH CAROLINA, 27603 PROJECT NUMBER: HTG-17000 t -G \-�� W W- �-G— W�WG WG SS SS 3 -7— SS SS 401ong-_ � 7—UL — NX—_ - 3 — FO N/F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7—UL VARIABLE WIDTH PUBLIC R/W CB TOP=351.99 12"RCP(E)=349.47 JB RIM=352.17 18"RCP(E)=349.34 12"RCP(W)=349.46 n"ono/nnu\—un Go — Ou SSMH / RIM=352.57 8"VCP(N)=344.38 8"VCP(S)=344.26 N/F FIRE HYDRANT PLANNED PARENTHOOD OF GREATER RALEIGH INC 100 S BOYLAN AVE PIN 1703-38-9868 DB 4798, PG 489 0.47 AC. ZONING: OX-7—UL HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F N/F 630 HILLSBOROUGH STREET 618 HILLSBOROUGH ST I HSA LIMITED PARTNERSHIP THE BAR STOOL INC PIN 1703-49-1348 I PIN 1703-49-2349 610 HILLSBOROUGH ST 600 HILLSBOROUGH ST DB 16997, PG 1152 DB 2790, PG 13 PIN 1703-49-3325 PIN 1703-49-4345 0.30 AC. HILLSBOROUGH 0.38 AC. I ZONING: NX-7—UL DB 4908, PG 342 0.34 AC. DB 13828, PG 1200 ZONING: NX-7—UL I S T VARIABLE WIDTH ZONING: NX-7—UL X I X 0.18 AC. ZONING: DX-7—SH `�------- (VARIABLE LE PUBLIC R/W I I r- �— WIDTH PUBLIC R/W) N — , � ZONING: DX-7—UL w ss SS ss ss Imo_ i u FO FO FO FO FO 8" W/L wv w W W_L< �w ■ ss ss SS Ss I x NIN �IC r 0 I PREVIOUSLY APPROVED PROJECT SEE CITY OF RALEIGH CASE #SR-45-16 I PRIVATE DRAINAGE ` EASEMENT Wv RALEIGH HOTEL GROUP, LLC 603 W MORGAN ST PIN 1703-48-4920 DB 16986, PG 2031 — — — — — — _ _ — 0.23 AC. F--------------- ZONTRG-Dk=7—t}L— — I-- — — — LEGEND QQ EXISTING IRON PIPE 0 IRON PIPE SET A CALCULATED POINT ® BORE HOLE SD SANITARY SEWER MANHOLE c0 SANITARY SEWER CLEANOUT M WATER VALVE ® WATER METER FIRE HYDRANT ❑T TELEPHONE PEDESTAL QT TELEPHONE MANHOLE 0 ELECTRIC BOX LIGHT POLE POWER POLE Wil CURB INLET Q STORM DRAINAGE MANHOLE ❑ YARD INLET Ac AIR CONDITIONER FX-X-X-X-1 ADDRESS BOX • BOLLARD FIRE CONNECTION ® FIBER OPTIC MARKER © GREASE PIT ACCESSIBLE PARKING `p IRRIGATION CONTROL VALVE FLOOD LIGHT ❑M MAIL BOX ® MONITORING WELL SIAMESE CONNECTION —o— SIGN O WELL ® WATER MANHOLE pCI LIGHT SINGLE DOCI LIGHT DOUBLE ® CABLE BOX FIBER OPTIC VAULT spy SPRINKLER HEAD SD STORM DRAIN PIPE OU OVERHEAD UTILITY LINES W WATER LINE SS SANITARY SEWER LINE T TELEPHONE LINE G GAS LINE UE UNDERGROUND ELECTRIC UT UNDERGROUND TELEPHONE —X X— FENCE LINE ZONING LINE GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 HERITAGE PROPERTIES, INC LU V) 0 z� U LU - LU m I (,n (V M �=z 00 zc�J V QOU O oc °C O� = J Imo 00 z`"z OJT _ -i � M � N Ljo z O U REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-XC1 CHECKED BY CHT DRAWN BY CHT SCALE 1"=20' DATE 12. 15. 2018 SHEET EXISTING CONDITIONS C-1 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION EROSION CONTROL NOTES 1. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN 7 DAYS (SEE TABLE BELOW) AFTER FINAL GRADE IS REACHED ON ANY PORTION OF SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN 7 DAYS (SEE TABLE BELOW) OF DISTURBANCE TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE, BUT WILL REMAIN DORMANT (UNDISTURBED) FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2. ALL CUT AND FILL SLOPES AND CHANNEL SIDE SLOPES WHICH ARE NOT TO BE PAVED, SHALL BE SEEDED UNTIL A GOOD STAND OF GRASS IS OBTAINED IN ACCORDANCE WITH: A. 100 LBS. PER 1,000 SQUARE FOOT GROUND LIMESTONE OR EQUIVALENT. NO SOIL TEST REQUIRED FOR INITIAL ESTABLISHMENT. B. 20 LBS. OF 10-10-10 FERTILIZER OR EQUIVALENT PER 1,000 SQUARE FOOT. C. VARIETIES TO BE SEEDED: C.1. SPRING SEEDING - MARCH 1 - APRIL 30; SPRING OATS 2.5 LBS. PER 1,000 SQUARE FOOT. C.2. SUMMER SEEDING - MAY 1 - AUGUST 1; WEEPING LOVE GRASS AT 2 OZ. PER SQUARE FOOT MIXED WITH 1 BUSHEL OF SAWDUST FOR UNIFORM SEEDING. C.3. ASPHALT TACK AND STRAW MULCH 6 GALLONS PER 1,000 SQUARE FOOT. ALL SEEDING SHALL BE MULCHED. 3. CITY ENGINEER AND OTHER APPLICABLE AGENCIES SHALL MAKE A CONTINUING REVIEW AND EVALUATION OF THE METHOD USED FOR THE OVERALL EFFECTIVENESS OF THE EROSION CONTROL PROGRAM. AN APPROVED EROSION AND SEDIMENT CONTROL PLAN MAY BE AMENDED BY THE APPROVING AUTHORITY IF ON -SITE INSPECTION INDICATES THAT THE APPROVED CONTROL MEASURES ARE NOT EFFECTIVE IN CONTROLLING EROSION AND SEDIMENTATION OR IF BECAUSE OF CHANGED CIRCUMSTANCES, THE APPROVED PLAN CANNOT BE CARRIED OUT. 4. CONTRACTOR SHALL LOCATE AND VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 5. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 6. EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED, SO THAT SEDIMENT LADEN RUNOFF FROM THE SITE WILL NOT ENTER STORM DRAINAGE FACILITIES. 7. PROPERTIES AND RIGHT-OF-WAY ADJOINING THE SITE SHALL BE KEPT CLEAN OF MUD OR SILT CARRIED FROM THE SITE BY VEHICULAR TRAFFIC OR RUNOFF. ANY MUD OR SILT THAT INADVERTENTLY GETS INTO ADJOINING PROPERTIES OR RIGHT-OF-WAY SHALL BE REMOVED IMMEDIATELY BY THE CONTRACTOR. 8. ALL CONSTRUCTION TRAFFIC SHALL ENTER AND EXIT THE SITE VIA THE CONSTRUCTION ENTRANCES. 9. EXCAVATED MATERIAL FROM TRENCHES SHALL BE PLACED ON THE UPGRADE SIDE OF THE TRENCH TO ALLOW MATERIAL TO ERODE INTO THE TRENCH. 10. CONSTRUCTION MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF GRADING CONTRACTOR UNLESS OTHERWISE NOTED, AND ONLY AFTER PERMISSION BY THE GOVERNING AUTHORITY. 11. SILT FENCE OUTLETS SHOWN ON THESE PLANS ARE BASED ON THE BEST TOPOGRAPHIC INFORMATION AVAILABLE AT THE TIME OF DESIGN. CONTRACTOR TO FIELD VERIFY AND ADJUST LOCATIONS OF SILT FENCE OUTLETS AND/OR PLACE ADDITIONAL OUTLETS TO INSURE THAT ALL LOW SPOTS ALONG THE SILT FENCE HAVE AN OUTLET. GENERAL DRIVEWAY NOTE 1. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS -OF -WAYS, NOT INCLUDING AN ALLEY. TRAFFIC CONTROL NOTES 1. THE CONTRACTOR SHALL CONDUCT ALL WORK IN A SAFE MANNER AND WITH A MINIMUM AMOUNT OF INCONVENIENCE TO TRAFFIC. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL AND SHALL ADHERE TO THE PROVISIONS OF THE MUTCD (MOST CURRENT EDITION). 3. PRIOR TO START OF WORK, A PRE CONSTRUCTION MEETING MUST BE SETUP WITH THE CONTRACTOR AND THE CITY OF RALEIGH TRANSPORTATION FIELD SERVICES STAFF. CONTACT ENGINEERING INSPECTIONS AT 919-996-2409 TO SET UP THE MEETING. 4. THE CONTRACTOR SHALL OBTAIN A RIGHT-OF-WAY OBSTRUCTION PERMIT FOR ANY WORK WHICH REQUIRES THE TEMPORARY CLOSURE OF A STREET, TRAVEL LANE, PARKING SPACE OR SIDEWALK FROM RIGHT-OF-WAY SERVICES AT LEAST 48 HOURS IN ADVANCE. 5. A TEMPORARY STREET CLOSURE REQUEST MUST BE SUBMITTED AT LEAST A MINIMUM OF TWO WEEKS PRIOR TO THE START OF WORK. SEE "RIGHT-OF-WAY CLOSURES" ON WWW.RALEIGHNC.GOV. SEND THE RIGHT-OF-WAY OBSTRUCTION PERMIT REQUEST TO RIGHTOFWAYSERVICESORALEIGHNC.GOV. 6. THE CONTRACTOR SHALL HAVE A COMPLETE SET OF CONTRACT DOCUMENTS AS WELL AS ALL PERMITS, APPROVALS AND EASEMENTS ON THE JOB SITE AT ALL TIMES. 7. THE CONTRACTOR SHALL REPAIR ALL DAMAGED DRIVEWAYS, DRIVEWAY PIPES, CURB AND GUTTER, SIDEWALKS AND STREETS TO EXISTING CONDITION OR BETTER. 8. SIDEWALKS MUST BE ACCESSIBLE TO PERSONS WHO ARE VISUALLY IMPAIRED AND PEOPLE WITH MOBILITY DISABILITIES. EXISTING PEDESTRIAN ROUTES AND ALTERNATE PEDESTRIAN ROUTES, DURING CONSTRUCTION, WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). PAVEMENT MARKING NOTES 1. ALL PAVEMENT MARKINGS SHOWN IN THESE PLANS FOR CITY OF RALEIGH MAINTAINED STREETS ARE SUBJECT TO FINAL APPROVAL FROM PUBLIC WORKS TRANSPORTATION OPERATIONS DIVISION. CONTRACTOR SHALL CONTACT TRANSPORTATION OPERATIONS AT 919-996-3030 FOR COORDINATION AND FINAL APPROVAL PRIOR TO PLACEMENT OF ANY PAVEMENT MARKINGS. MARKINGS WITHIN NCDOT RIGHT-OF-WAYS SHALL BE IN COMPLIANCE WITH NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL SIGNS & PAVEMENT MARKINGS ASSOCIATED WITH THE PUBLIC STREET SYSTEM WILL REQUIRE APPROVAL BY CITY COUNCIL TO BE ORDINANCED FOR ENFORCEMENT. 3. ALL PAVEMENT MARKINGS SHALL BE PLACED PER THE NCDOT DIVISION 12 STANDARD DETAILS. BICYCLE LANE MARKINGS SHALL BE PLACED PER CITY OF RALEIGH STANDARD BICYCLE FACILITIES DETAILS. GENERAL RAILROAD NOTES 1. CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF THE NORFOLK SOUTHERN'S NSCE-8 SPECIFICATIONS. 2. PIPELINE AND CROSSINGS TO BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH LAST APPROVED AMERICAN RAILWAY ENGINEERING AND MAINTENANCE OF WAY ASSOCIATION SPECIFICATIONS FOR PIPELINES CONVEYING FLAMMABLE AND NON-FLAMMABLE SUBSTANCES. 3. BLASTING NOT PERMITTED. SITE PLAN NOTES 1. NON -ALLEY LOADED DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 20 FEET FROM THE INTERSECTION OF TWO STREET RIGHT-OF-WAYS. THE MINIMUM CORNER CLEARANCE FROM CURB LINE OR EDGE OF PAVEMENT OF INTERSECTING STREETS SHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY OF THE RADIUS OF CURVATURE, OR 20 FEET FROM THE INTERSECTION OF RIGHT-OF-WAY LINES, WHICH EVER IS GREATER. THE RADIUS OF THE DRIVEWAY SHALL NOT ENCROACH ON THE MINIMUM CORNER CLEARANCE. REFER TO SECTION 6.5 OF THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL FOR ADDITIONAL DETAILS. 2. WITHIN THE AREA DEFINED SIGHT TRIANGLES SHOWN ON THESE PLANS THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE BERMS, OR PARKED VEHICLES BETWEEN THE HEIGHTS OF 24 INCHES AND 8 FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVEL WAY IF NO CURB LINE EXISTS. REFER TO SECTION 6.12 OF THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL FOR ADDITIONAL DETAILS. 3. MULTIWAY STOP CONTROL WILL NOT BE USED AT ANY PUBLIC STREET INTERSECTION WITHOUT AN ENGINEERING STUDY TO PROVIDE DATA TO CITY OF RALEIGH TRANSPORTATION DIVISION THAT THE MULTIWAY STOP INSTALLATION WARRANTS CAN BE MET AND ORDINANCED BY CITY COUNCIL APPROVAL. 4. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 5. ALL DIMENSIONS SHOWN ON SITE PLAN ARE MEASURED TO FACE OF CURB UNLESS OTHERWISE NOTED. 6. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 7. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION AND TO THE SATISFACTION OF THE OWNER, BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 8. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 9. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 10. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 11. PRIOR TO BEGINNING CONSTRUCTION BEYOND EROSION CONTROL MEASURES, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH PUBLIC WORKS DEPARTMENT (919) 996-2409, AND A REPRESENTATIVE OF THE ENGINEER AND OWNER. THE PURPOSE OF THIS MEETING IS TO REVIEW THE SPECIFIC COMPONENTS OF THE PLAN AND OPERATION OF THE FACILITIES DURING CONSTRUCTION. 12. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 13. ACCESSIBLE RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF RALEIGH UNIFIED DEVELOPMENT ORDINANCE (UDO) DETAILS. 14. ALL SIDEWALKS THAT CONNECT TO THE PUBLIC RIGHT-OF-WAY MUST BE ACCESSIBLE TO PERSONS WHO ARE BLIND, HAVE LOW VISION AND PEOPLE WITH MOBILITY DISABILITIES. PEDESTRIAN EXISTING ROUTES AND ALTERNATE PEDESTRIAN ROUTES DURING CONSTRUCTION WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 15. TYPICAL PAVEMENT SECTION DETAILS ARE SHOWN WITHIN THIS SET AND INTENDED TO BE A MINIMUM PAVEMENT SECTION REQUIREMENT. THE CURRENT GEOTECHNICAL REPORT SHALL OVER -RIDE ALL TYPICAL PAVEMENT SECTIONS SHOWN, IF THE GEOTECHNICAL ENGINEER DEEMS A HEAVIER SECTION IS REQUIRED. 16. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO SUBSTITUTION OF ALTERNATE EQUIPMENT. 17. IF UNFORESEEN CONDITIONS DEVELOP DURING CONSTRUCTION, REFER TO THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL AND CONTACT PUBLIC WORKS STAFF FOR FURTHER GUIDANCE. 18. ALL SIGNAGE ASSOCIATED WITH THE PUBLIC STREET SYSTEM SHALL ADHERE TO MUTCD STANDARDS AND SPECIFICATIONS. widdt A Right-af-way width Wlth center turn lane 90' With median 94' B Back •of•curb to back•of•curb With center turn lane 62' Wrth median Or 5treetscape C Sidewalk (mint ......... ...... _...__..... _ S' ^ ... _...... ........ ..... �...._... D Planting area (min) ._... 1V _, �. ... Trivelway E Parallel parking lane $ 5' _ ... ..... ......-----........ - ._ ...,. F Bike lane _.-...- _ ...-..._,.--------. . - _6' ... . ...,.... _..... _ G Travel lane ... .... _...... .,.... ...... 1!' .. ...--....,_........._....�...._......._...._... H Center lane .....�..- Striped turn lane 11' Median is' Gem" � Walkway type Sidewalk Planting type Tree grate / lawn Tree spacing 40' o.c. avg Parking type Parallel HILLSBOROUGH STREET AVENUE 3-LANE PARALLEL PARKING N.T.S. CIDIEI F GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 5. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 7. CONTRACTOR SHALL DETERMINE LOCATIONS FOR SPILL CURB TO PROVIDE POSITIVE DRAINAGE TO STORM STRUCTURES THROUGHOUT THE SITE. NO "BIRDBATHS" SHALL BE CREATED WITHIN THE CURB AND GUTTER OR ASPHALT PAVED AREAS. STORM DRAINAGE NOTES 1. ALL STORM DRAINAGE PIPES SHOWN SHALL BE CLASS III REINFORCED CONCRETE (RCP) UNLESS NOTED OTHERWISE. 2. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH STANDARDS. 3. ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4 ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 5. ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 6. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD, USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 7. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 8. MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE OR GEOTECH AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 9. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95 % OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 11. ALL CONCRETE PIPE AND PRECAST STORM STRUCTURES SHALL MEET NCDOT STANDARDS AND STAMPED ACCORDINGLY BY MANUFACTURER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL PIPE AND STRUCTURES FOR CRACKS OR BREAKS, PRIOR TO INSTALLATION. ANY DAMAGED ITEMS SHALL NOT BE INSTALLED. 13. "KNOCK -OUT" BOXES OR HDPE PIPE SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAYS UNLESS APPROVED IN WRITING BY CITY OF RALEIGH STORMWATER DEPARTMENT. RETAINING WALL NOTES 1. THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE TOP OF THE WALL. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING RETAINING WALLS ARE NOT LOCATED IN ANY STREAM BUFFERS, AND THEIR CONSTRUCTION DOES NOT ENCROACH INTO ANY ADJACENT PROPERTIES DUE TO ANY BATTER INCORPORATED IN THE DESIGN OF THE WALLS. 2. RETAINING WALLS ARE TO BE DESIGN -BUILD PROJECTS BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALLS. 3. RETAINING WALLS SHALL BE ASSUMED TO BE BACKFILLED WITH OFF -SITE BORROW MATERIAL OR PROCESSED FILL, UNLESS THE CONTRACTOR CAN PROVIDE TO THE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER, THAT READILY AVAILABLE ON -SITE SOILS CAN BE USED. 4. THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING OR ABOVE GRADE TO THE TOP OF THE CAP BLOCK COURSE SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. 5. ALL RETAINING WALLS OVER 30" HIGH SHALL HAVE A SAFETY FENCE (DESIGN BY OTHERS). 6. ANY PART OF ANY RETAINING WALL THAT EXTENDS INTO THE RIGHT-OF-WAY WILL REQUIRE AN ENCROACHMENT AGREEMENT. ENCROACHMENT AGREEMENTS FOR RETAINING WALLS SHALL BE APPROVED PRIOR TO CONSTRUCTION DRAWING APPROVAL. 7. ANY TIEBACK SYSTEMS FOR THE RETAINING WALLS SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAY. 8. STORMWATER RUN-OFF SHALL BE DIRECTED AWAY FROM RETAINING WALLS. ANY RUN-OFF FLOWING TO AND OVER A RETAINING WALL SHALL BE KEPT TO AN ABSOLUTE MINIMUM AND BROUGHT TO THE ATTENTION OF THE WALL DESIGNER PRIOR TO THEIR DESIGN. i I H I Is F I E I C A liirdtll -- A Righuof-way width With center turn lane With median B Back. of -curb to back -of -curb With center turn lane With median 5treetscape _ G Utility placement, easement �minl _D Maintenance strip (min) E Sidewalk (min) F Planting area (mtn) Tra►re" G Bike lane H Travel lane Centeriane Striped turn lane Median General Walkway type Planting type Tree spacing 7s' 79' 4 8' 52, 5' z; 6' 7' 11' Sidewalk Tree lawn 40' o.c. avg MORGAN STREET AVENUE 2-LANE DIVIDED N.T.S. i Tl117iI9 CITY OF RALEIGH PUBLIC UTILITIES STANDARD UTILITY NOTES (AS APPLICABLE 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS, DETAILS & SPECIFICATIONS (REFERENCE: CORPUD HANDBOOK, CURRENT EDITION). 2. UTILITY SEPARATION REQUIREMENTS: a) A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. b) WHEN INSTALLING WATER &/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER & MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. c) WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. d) 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER & STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. e) MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN & RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER & RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS & A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (PER CORPUD DETAILS W-41 & S-49). f) ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS & SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL REUSE MAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER & SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. THIS INCLUDES ABANDONING TAP AT MAIN & REMOVAL OF SERVICE FROM ROW OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. INSTALL 3/4" COPPER* WATER SERVICES WITH METERS LOCATED AT ROW OR WITHIN A 2'X2' WATERLINE EASEMENT IMMEDIATELY ADJACENT. NOTE: IT IS THE APPLICANT'S RESPONSIBILITY TO PROPERLY SIZE THE WATER SERVICE FOR EACH CONNECTION TO PROVIDE ADEQUATE FLOW & PRESSURE. 8. INSTALL 4" PVC* SEWER SERVICES 0 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE & SPACED EVERY 75 LINEAR FEET MAXIMUM. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SANITARY SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0' ABOVE THE NEXT UPSTREAM MANHOLE. 10. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 11. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. 12. GREASE INTERCEPTOR / OIL WATER SEPARATOR SIZING CALCULATIONS & INSTALLATION SPECIFICATIONS SHALL BE APPROVED BY THE CORPUD FOG PROGRAM COORDINATOR PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTACT TIM BEASLEY AT (919) 250-7825 OR TIMOTHY.BEASLEY@RALEIGHNC.GOV FOR MORE INFORMATION. 13. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX-13 OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HARTLEY AT (919) 996-5923 OR JOAN I E. HARTLEYORALEIGH NC. GOV FOR MORE INFORMATION. ADDITIONAL UTILITY NOTES: 1. ALL WATER MAINS, SERVICES AND FIRE SERVICES GREATER THAN 2" DIAMETER ARE TO BE DUCTILE IRON PIPE. 2" & SMALLER DOMESTIC SERVICES MUST BE TYPE K SOFT COPPER (WITHOUT FITTINGS) TO THE WATER METER. 2. ALL SEWER MAINS SHALL BE EITHER PVC OR DUCTILE IRON PIPE AS SHOWN ON THE PLANS. ALL PIPE MATERIAL SHALL MEET CITY OF RALEIGH STANDARDS AND SPECIFICATIONS AS DEFINED IN THE LATEST ISSUE OF THE PUBLIC UTILITIES HANDBOOK AND/OR UNIFIED DEVELOPMENT ORDINANCE (UDO). 3. ALL FIRE HYDRANTS ALONG PUBLIC R/W LINES SHALL HAVE A 3'Wx3'L CITY OF RALEIGH WATERLINE EASEMENT ONTO ADJACENT PROPERTY. 4. ALL SANITARY SEWER INTERCEPTOR LINES (12" AND LARGER), AS WELL AS MANHOLES AND FITTINGS ASSOCIATED WITH THE INTERCEPTOR LINE, SHALL BE INTERNALLY LINED WITH PROTECTO 401 OR APPROVED EQUAL TO PREVENT HYDROGEN SULFIDE CORROSION. SEE THE CURRENT CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT HANDBOOK FOR APPROVED COATINGS AND APPLICATION METHODS. 5. IN ACCORDANCE WITH GENERAL STATUTE 87-121(G), ALL UNDERGROUND UTILITIES INSTALLED AFTER OCTOBER 1, 2014 SHALL BE ELECTRONICALLY LOCATABLE. CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT FOR DETAILS AND SPECIFICATIONS FOR MEETING THESE REQUIREMENTS. 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL WATER AND SEWER MAINS WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE OWNED, OPERATED, AND MAINTAINED BY THE CITY OF RALEIGH. 8. ALL WATER AND SEWER MAINS NOT WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE PRIVATELY OWNED, OPERATED, AND MAINTAINED BY THE PROPERTY OWNER. 9. ALL UTILITY SLEEVES SHALL BE SCHEDULE 40 PVC AND INSTALLED WITH 2' MINIMUM COVER. BOTH ENDS SHALL BE CAPPED AND MARKED. A Right of•waywidth 6-V B Back-of•curb to back -of -curb 3u 5treetscape C Utility placement, easement {min) 5' D Maintenance strip Amin) 2' L Sidewalk (min) _ 5 F Planting area I<minj 6' Traivellway G Bike lane 7' _...... ...... ...... �....._......_ m... _ _ .. _ .»...� .f.. . . H Travel Ian e 11 ALL TRAFFIC CONTROL/DETOUR PLANS AND """"""""'-""""'� "'" PEDESTRIAN DETOUR PLANS TO BE PROVIDED BY Germ CONTRACTOR AND COORDINATED WITH THE CITY Walkway type � �W Sidewalk OF RALEIGH TRANSPORTATION STAFF Planting type Tree lawn Tree spacing .„ - .�..» .. 41T o_c. avg ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS SPECIFICATIONS AND DETAILS. BOYLAN AVE AVENUE 2-LANE UNDIVIDED N.T.S. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE a" ` PROPERTIES, INC LU r� V z� U w LU M (V M V = z 00 z J �� V Q O OO = oc ttttttJ 0 m O m z z OLU J J U ZN) M < L.I. N z O U REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-NI CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET PROJECT NOTES PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION I v 0 a X / I / I I I I I I I 1 i w-t HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F F N 618 HILLSBOROUGH ST HSA LIMITED PARTNERSHIP / 630 HILLSBOROUGH STREET 610 HILLSBOROUGH ST THE BAR STOOL INC PIN 1703-49-1348 I PIN 1703-49-2349 '600 HILLSBOROUGH ST DEMOLITION LEGEND � DB 16997, PG 1152 DB 2790, PG 13 PIN 1703-49-3325 PIN 1703-49-4345 / DB 4908, PG 342 HYDRANT - ! ZONING: I EXISTING 0.38 AC. I DB 130 18 AC. 828, FIG 1200 ZONING: NX-7-UL 0.34 AC. HILLSBOROUGH S' T � ZONING: NX-7-UL ZONING: DX-7-SH TREE TREE OR OTHER VEGETATION I SAWCUT REMOVE AND TO BE REMOVED - , - - I (VARIABLE WIDTH PUBLIC R/W) EX. VARIABLE WIDTH � REPLACE AS REQUIRED REMOVE AND _ _ _ g - - PUBLIC R/W FOR UTILITY TIE-IN PER ���T L��1%��� UTILITY -� - - - E�i�RC�4fIRED - - - - - - _ - �-� - I EIGH TO BE REMOVED G G- G G - CITY OF RAL STANDARDS - -w w w �w CI ` EX 7A LfRE- _ -� _ _ =1_ - - - - - - - -� [E}- Fo I - - - - - - AREA TO BE REMOVED - - - - - - _ - _ (SIDEWALK, CURB AND GUTTER, 3 w- fi- FG - - - w- G G G G <- = d`-- -- Fo - SS SS - w� c G - - - - _ _ - - _ - - - _ _ _ASPHALT,CONCRETE STRUCTURES, SS \ EX. 8" CIP W/L (ASSUMED LOCATION) \ _ _ zr_ _ _ _ - - - PAVING, ETC.) - SS ss SS LIMITS OF -w \ = - _ 3 \ \ SS SS SS _ EX. 8" SS EX. 8" W/L wv \ _ �- so - (TYp,) ; s SS S• _ w \ �, -NOTE: SEE PLAN FOR DETAILED DEMOLITION PROCEDURES, IEX. SSMH � _� \ 9 CONTRACTOR TO FIELD ss SS ss ss SS -�- ^� � SEQUENCING AND SPECIFICATIONS. SS RIM=355.14 / -�-� SERVICE TO BE - VERIFY LOCATION OF -DISCONNECTED AT THE MAIN PER CIiY \ 9 8"VCP(N) 348.98 ` EX. WATER SERVICE 8'VCP(E)=348.61 DEMO AND REMOVE - OF RALEIGH STANDARDS. IN LIEU OF 8'VCP(W)=348.73 / ` 0 SAWCUTTING ACROSS ROAD, POTHOLE-� EXISTING-WRKING AREA 9 CONNECTION, DISCONNECT THE SERVICE INCLUDING EXISTING ALIMITS OF PAVEMENT, WALLS, BAND MAIN, AND FILL ENTIRE DISTURBAN 9 \ SIDEWALKS, CURB AND I 6 - -to ABANDONED SERVICE WITH FLOAWABLE (TYP-) - - GUTTER, PAINT STRIPING, UNDERGROUND 3 FILL PER RALEIGH STANDARDS. LIGHT POLES, CLEANOUTS ELECTRICAL / EX. ELECTRICAL - 'SAWCUT ANB-RSP6ACE EXIST! _ 5 AND FENCES I CURB AND PAVEMENT. GRANITE �VAULT AND LIGHT _ - �o -J POLE TO REMAI ---CURB TO BE SALVAGED AND TO - - - / EhW N- � ss � IF ss�� ss 3s. � SS SS - 3 w EX. ELECTRICAL / VAULT TO REMAIN / W E EX.OVGREEA��NITE ALACED CURB TO BE - F III 3 I -I - - �- - - - - - -� - - - - I ' MET RATER ND WITH LIKEMATERIA DEMO AND REMOVE ; I I / \ ® DEMO AND I J- �o REMOVE EXISTING II EXISTING PAVEMENT, STORY BUILDING I II I CONCRETE, SIDEWALKS, LIMITS I I II I I ® II I I I CURB AND GUTTER 1 \, D;PE - I` (i) Ex. BOLLARDS, EX. 8" �II I DIP PROPERTY LINE I ELECTRICAL AND WATER LINE � TO BE ABANDONED II PROPERTY LINE TELEPHONE BOXES I I I N/F I�IO zl� F II ■ I I I I I II TO BE ABANDONED TO BE REMOVED I II 3 1 I GLENWOOD ONE OFFICE, LLC I I I I' 1 I I I I L L_ I II I ` II 1 GLENWOOD AVE I 1 FMW AT 70 I cn 1_4 Q I I I I I - -� I \ / I PIN 1703-49-4101 I I I 701 HI1, HILLSBOROUGH LLC I I I I I I /F I I N F II' I DB 16926, PG 570 I� _ � ,� � I � I N LSBO49-01 ST ( L I I ` GLENWOOD TWO LLC PARTNERSHIP NO 3 II I \ / /II 0.70 AC. I 1 PIN 'I� 3 49-0106 � R EX. WA M R 1 623 HILLSBOROUGH ST ( \ � j� DB 1I 37, PG 2509 -I r ITO BE R MO III I c I PIN 1703-49-1158 I I VALLAS FAMILY LTD I I I� / I ZONING: DX-12-UG, DX-12-UL Ii1 I BMI 87, PG 1251 I Iw I I / I I DB 17043, FIG AC. 1871 1 621 HILLSBOROUGH ST II I I / II / I EX. 4" DIP I� I F 3AC. ( o I PIN 1703-49-2128 DEMO AND_WATER LINE I � I o I DB 6218, PG 552 I \ - - - IINX-7-UL I a ■ I � � I ZONING: DX-12-UG I REMOVE EXISTING 1 A I 0.17 AC. I --2STORY BUILDING -- - _I / I� \ ■ - - _ I ZONING: DX-12-UG II - - -- I , II PROPOSED F U E PROJECT SITE I I / I ---- I II I I I I UL crllr = IilO F -RE R N E ONLY IIII oIIIw IW■II �VARIABLE WIDTH IDTH III III NIIIIIIII I 33 II I -- MI II- I I � 7 (A ED 100 IMPERVIOUS EX. DRAINAGE EASEMENT To BE UATI .�73539 I AeaDONED I�0 I -�3 CASE S-%8 �N REMOVE DEMO AND REMOVE IN, DEMO AND IPEREMOVE EXISTING EXISTING CONCRETE WALK 'EX. WATER SERVI E TO BE AREA INCLUDING EXISTING/ 1-STORY BRICK/DISCONNECTAT THE MAIN PER DUMPSTER PAD, WALLS, OF oel SIDEWALKS, CURB AND BUILDING PROPERTY LINE I\ROAD POTHOLE \OTO BE ABANDONED CONNECTION, DISCONN CT THE SERVICE CLEANOUTS, ANDFENCES AT THE INIL�NTIRE ABANDONED I III I ITH 1 1 i WABLE 7 -�- FILL PER RALEIGH STANDARDS. \ \ EX. POWER POLE AND \ OVERHEAD POWER TO BE \ REMOVED OR RELOCATED AV NEEDED. CONTRACTOR TO COORDINATE W/ APPROPRIATE \ \ UTILITY COMPANY EX. SS \ \ RIM=353.13 \ \8"VCP(S)=3A.01 I �I I? I �I II I II EX. VARIABLE WIDTH 700 WESTNMORGAN LLC PUBLIC R/W I PIN 1703-49-0004 DB 11755 PG 933 - - _ E 1 EX. PAINT TO BF� i - REMOVED Li / 1,IILL1111 EX. GAS LINE I / / TO REM IN I JI U= a lliiiil�_-6✓ _ LD �D REMAIN IF POSSIBLE:--- W - JI I c I II I I ® -� - -•• -an- -__ II 9 II I II = --- -----_ _ _ - - 3 EX. WATER METER I - ------------ r ` / - TO BE REMOVED � i----- 1 EX. AC UNITS TO N I M II I BE REMOV D-� I I I M PROPERTY LINE / II - _ - \ I I TO BE ABANDONED L J I/ LIMITS OF % J I I DISTURBANCE / EX. D % / SO TYP.) J I /// ELECTRICARICAITO / / / I I 11-1 PREVIOUSLY APPROVE P I I - - --- - - - - BE REMOVED/ LIL - -- / ���� \ / - (TYP.) \ % N/F SEE CITY OF RALEIGH -n / �',� COWELL PROPERTIES LLC \ Y� CASE #SR-45-16 J _ I " 615 HILLSBOROUGH ST.PIN II I I I I EX. STAIRS TO BE I ® I `'®, �� DB 11575,49-2196 PG 8811 �401, REMOVED - 0.49 AC. - - .� ZONING: DX-12-UG, _ L / --LTT -- -�----rrT � - I � DX-�� \ TO BE REMOVED J STORM DRAINAGE r \ VARIABLE WIDTH EX. I I OR ABANDONED IN li I EX. LIGHT POLE-; I 3 TO BE REMOVED DRAINAGE EASEMENT / 348 PLACE AND FILLED I // L I l I I I (TYP.) I II �TO BE ABANDONED / - - - - \ ' ` WITH FLOWABLE II I \ I FILL. J/,� 1 N/F � � � EX. WALL T0/ BE � o� I I I I GLENWOOD TWO LLC J I REMOVED _ _ _ _ - 34� II Q II 11 S BOYLAN AVE I L - 3 / WATER LINE U I PIN 1703-49-1076 EX. UNDERGROUND I I 3 `_1z II of I I DB 17043, PG/1865 ELECTRICAL TO BE I / / I / I I L1 0.39 AC.- REMOVED (TYP.) TO BE ABfNDONED - 346 ZONING: DX-12-UL EX. DI L1 L7 N WI I / GRATE=343.53 I II cn I I - r - 12"RCP(E)=342.65 TO BE REMOVED III la -�" I I ! 3 ► II i / / z DEMO AND REMOVE III 3 I 9 I P I I EXISTING BRICK BUILDING II / AND PARKING DECK PROPERTY LINE � � 1 � � J INCLUDING EXISTING r - - - \ = I TO BE tBANDONED PAVEMENT, PARKING KIOSK, I 'EX. DIco A II I X I x 1�9 I I I I GUTTERSIDEWA,LIGHTPOLESS, CURB , AND G "=343.47 W w I I CLANOUTS I 12(S)=340.56 s I I I I 11 0.151 AC. EX. PAINT ro BE 1 I 12 RCP(W)=340.56 I / I I I L I // ZONING: NX-7-UL FI II r I 1 � TO BE REMOVIED I / I T/C=343.1 REMOVED 1 � EX. CB I I / TOP C351.99 ,II ■ 9 EX. GAS LINE (ASSUMED I N.\� O \ d I 15"RCP(N- 37-37 12"RCP(E)=349.47 II II I ONTLOCATRACTOROTOEF FIELD I \ 15 RCP(S)=�37.27 I I III I I EX. 15 RCP / EX. JB I I II ]¢ I VERIFY EX *I \\ TO CITY OF CB TO BRA RALEIGH CONVERTED / ' I I III I III la I I I I I I // RIM 352.17 EX. CB TO BE CONVERTED 1 STANDARD CB I / ' 342 _ 18"RCP(E)=349.34 I I / 9 II I � � TO CITY OF RALEIGH I I I I � I II � EX. GREASE ` 7 INTERCEPTOR 12"RCP(W)=349.46 / II I L- -STANDARD CB EX. JB I' _ \ I \ I I i I II 12" RCP(NW) 359.58 - - - - - --(ASSUMER LOCATION - - - I- - - - - - - - - - I _ /' I EX. II 12" PVC II � i'-Owo-%.w d . a/ - - / I I I RIM=350.40 - - - - - - - _ I I -T----�- I - INV INV IN( )1 346.41--�\ • w �s�sz - \� _ EX. GAS LINE - - - ° �i _ ° r� - - / 8 no -� i no _ _ - -� - - N/ - \� T -REMAIN SS _� ��`�SS 1� a P - -_�_� �G c 6j '� can Wv so EX. C \ \ so - - - - - „- - - - _ _ - "'1"�- - EX. 15, RGsC� / \ TOP=35�1. 6 \ �� V A EX. 15" RCP �'o o sd �� �= - -� M M M M- / \ 12"RCP(E)=35�0.403 - _ - \ \ \ EX. GAS LIN\ �" i� X 11�RGP---=- ---� ����SD� I \ \ \ 6 EX. CB _ \ \ TOP=343.17 EX. B I w (n _ EX. f" CIP W/L \ \TO REMAIN 15"RCP(S)=338.31 \ 6 1yy 6 �- - -R T/C=345.37 / ■ I m U LIMITS a m 9 i EX. FIRE ` �� m OR ci -�-w 15' RCP(E)=339.17 / iR EX. fEOWER POLE A�JD ! / DISTURBANCE ! �- - w w w w f5"RCP(W)=339.07 HYD�ANT OVERHEAD POWER TO BE '- (TYP.) / c1 (ASSUMED LOCATION) rn a. EX. JB / RELOCATED AS NEEDED. / �- / -� / CO CTOR TO COORDINATE Ig - �� RIM=343.59_ �_ z RIM=343.07 I ` / W APPROPRIATE UTILITY I SAWCUT REMOVE AND EX. SEWER SERVICE TO BE DISCONNEC D / INV IN(N)=338.7 E J -mmmi-4 5" RCP(NE)=3386 / COMPANY I / REPLACES/ AS REQUIRED AT THE MANHOLE PER CITY OF RALEIGH / 15"RCP(W)=33&�79 =34 0 X Q 15' RCP E =330 6 -� I / I I FOR UT LITY TIE-IN PER / / EX. SMH w ()- - CITY 0 RALEIGH STANDARDS. IN LIEU OF SAWCUTTING 15"RCP(E)=3,38.79 15 RCP(N)=336.93 _ c, ACROSS ROAD, POTHOLE CONNECTION, / RIM 345.8. / 15"RCP(W) 336.93 w 2" PVC(W�336.16 -� STANDARDS DISCONNECT THE SERVICE AT THE MAIN, / 6" )=338.18 / ; 15" RCP(E)=336.93 i� (NW)=339.21 AND FILL ENTIR ABANDONED SERVICE WITH / 8"VCP(E)=338.23 / I 18" RCP(S)=336.06 -,' F1 AW613LE FIL PER RACIGW STANDARDS. / / EX. 8" SS -----1--- --_ ■ no Z - ---�- _C -� s ss ss SS S EX. S SS no EX. SSMH 1"01 �-as �� ---_RIM=352.57 ---� ?----S� ----_____ 8"VCP(N)=344.38 I\ / I -- --� 3 __- s'vcP(s)=344.2s Ir I� \ I EXISTING - - - - - _ __L A III I I I� 1VJ1 ®R G1�1! S 1 DEMO AND REMOVE �►' 5 - - SS SS `� 's,� Ma/ 10 I �I so �11 / % O N F EX. FIRE I I VARIAB I ! EXISTING t0NCRETE - - - �- ss r� ,d/ 1�J PLANNED PARENTHOOD OF GREATER HYDRANT I I lI I I III (VARIABLE WIDTH PUBLIC R W r - - - - - - - - - M� / I / ) DRIVEWAY, PAVEMENT, I IM - - I - " RALEIGH INC I 1 I II I r \ i WALLS, SIDEWALKS, CURB I I I 100 S BOYLAN AVE 1 I I I ' I II I I N/F ANODES UTTER, AND LIGHT I I I I I I I I N/F PIN 1703 38 9868 II I I CROCKER FAMILY 344 L I- - III RALEIGH HOTEL GROUP, LLC DB 4798, PG 489 I ~ II I I I + II ( I PROPERTIES, LLC I \ I I �r� I Jill T - - I I - - - - Al - v 603 W MORGAN ST 0.47 AC. I I �I 615 W MORGAN ST 1� I 101 I l PIN 1703-48 4920 ZONING: OX-7-UL I II EX. VARIABLE WIDTH PIN 1703-48-1885 ++ 4I3 I DB 16986, PG 2031 LIC I I� DB 16759, PG 165 1 - - - - - _ / I N - t - -I-I - - -I r- - - - -rl- - - - - - - - - 0.23 AC. (_'--------------------- 0.63 AC. ZONING: DX-7-UL ZONING: DX-7-UL EXISTING GAS LINES ARE PRESENT ON SITE. CONTRACTOR IS TO VERIFY LOCATIONS PRIOR TO ANY EXCAVATION/ CONSTRUCTION ACTIVITY TO MAINTAIN THE SAFEST ENVIRONMENT POSSIBLE. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS CONTRACTOR TO COORDINATE WATER METER REIMBURSEMENT WITH CITY OF RALEIGH PUBLIC WORKS DEPARTMENT z GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE PROPERTIES, INC W z� vW / W M I..L (V M= z 00 z J �:O< VQCC- 0 °COS = J 0 CO O m z z O J �_ W J U M < N) N z O U �\A CAI • 9 . S. S\-P...``�• REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-XC1 CHECKED BY CHT DRAWN BY CHT SCALE 1"=20' DATE 12. 15. 2018 SHEET DEMOLITION PLAN C-3 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION I v t v a`j F a a X HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F N/F SITE LEGEND I 618 HILLSBOROUGH ST L_ 630 HILLSBOROUGH STREET HSA LIMITED PARTNERSHIP I THE BAR STOOL INC I / PIN 1703-49-1348 PIN 1703-49-2349 610 HILLSBOROUGH ST o I X DB 16997, PG 1152 DB 2790, PG 13 PIN 1703-49-3325 600 HILLSBOROUGH ST v SIGNAGE DB 4908, PG 342 PIN 1703-49-4345 0.30 AC. 0.38 AC. DB 13828, PG 1200 ZONING: NX-7-UL I ZONING: NX-7-UL 0.34 AC. z o 0.18 AC. �, POWER POLE / I I \\ - - ZONING: NX-7-UL x j� ZONING: DX-7-SH — — — y — _# -- / I ❑E - _ _ _ I I c rn TRAFFIC DIRECTIONAL ARROW IEX. PAINT � —1__--� I ACCESSIBLE RAMPS STOP BAR -- I (TYP.) �-----I --� ==�1----��- #�% �1 E❑ - --ter- TYPE® TYPE QB TYPE© EX. PAINT o-----__-===�i 1(--------- -- PROPERTY LINE OX-7-UL CITY OF RALEIGH STANDARD 1- _ _ _ _ _ a 1--�_ \ I GRANITE CURB ALONG �STIN �� — _ � = = 1� — — — NX-7-UL ; SAWCUT REMOVE AND I I HILLSBOROUGH STREET. REUSE HILLSBOROUGH —L - - - - - - RIGHT-OF-WAY LINE REPLACE AS REQUIRED GRANITE IF POSSIBLE. I- - - I — — EASEMENT LINE FOR UTILITY TIE-IN I (VARIABLE WIDTH PUBLIC R W I I SAWCUT REMOVE AND I CITY OF RALEIGH - 3 STANDARDS ' I- -4 " PRIMARY STREET I CENTERLINE REPLACE AS REQUIRED DX-12-UG A�3 j•�..RTE PARL FOR UTILITY TIE-IN PER • • • • • • • • ADA ACCESSIBLE ROUTE I G L+t 11 V EX. PAINT �t7 CITY A RALEIGH oBIKE RACK �� `" STANDARDS 6' WIDE PEDESTRIAN \ I L` (TYP) FOR HARDSCAPE DETAILS SEE � — _ CROSSWALK (TYP.) N LANDSCAPING PLAN AND DETAIL Of _j � ON SHEET D-2 (TYP.) I I EX. 4'X6' ADA TREE o TREE GRATE (TYP.) GRATE (TYP.) e 1/0 L - - - - _ _ - - PPROIPOSED CONCRETE WALCAST CONCRETE I 11T �� \ A - - - - - - - -LS TYP. SIDEWALK - (DESIGN BY OTHERS) I IL L1 I O ACCESSIBLE 1 RAMP (TYP.) � — — / ao CANOPY — r — — _ — _ _ — S87'03'40"E— — OVERHANG N87'09'47"W © — — _ — —E— �,r - - - - - _� - _ (TYP.) - - - - - 34.76' S2'S0' 13"E 18 65S87*03,40"E - - -�I I� —— r I 1= I I - - - - - - _ _ _ _ - - - 59.66' - 1.35 N2'29'22"E -II J I III I I 27.1' 1 - - - - , • • S8T03'40"E i i - - - 2.78' I FOR HARDSCAPE DETAILS SEE 1 I II L I I I I ' // I I °`,N + I / r- - I LANDSCAPING PLAN AND DETAIL T1TTl lTI L ON SHEET D-2 (TYP.) I I EX. PINT TAPERED I I I I STEP WITH HANDRAIL I I J N/F ` - - 1 II SAWCUT LINE FMW AT 701 HILLSBOROUGH LLC I I 701 HILLSBOROUGH ST I I II I I PIN 1703-49-0106 I I II DB 16937, PG 2509 BM 1987, PG 125 0.43 AC. EX.I PAINT BI R CK I ZONING: NX-7-U I I I ( ) CITY OF RALEIGH ANDARD GRANITE CURB ALO G,- S. BOYLAN AVE. R US{� I I I EX. GRANITE CURB IF POSSIBLE. _ � I I w r Q I CONCRETE 22.5 1 W8 1 SIDEWALK a I �E:II� I I I I W I �C&� i C I N DO I _ �Z r I N� I ---� a " Z 14'R i t C/0 Z I I I I , I I 1 I II I , PROPOSED FUTURE PROJECT SITE I 1 $ II I4'R I REFERENCE ONLY 1 11 (ASSUMED 100% IMPERVIOUS) I 11 I I TRANSACTION# 573539 1 1 II HHATCH EAVY DEN TES I CASE # SR-100-18 I CONCRETE P. I I I I I II II I PROPOSED R/W Ll TREE GRATEI(TY . P )17.5' II C L TO F C II I I II 32' I II N/F I II SAWCUT LINE C/L TO RI/W 700 WEST MORGAN LLC IB 4 1170 5,PG0 004 D933 II 1 II 0.15 AC. II x x ZONING: NX-7-UL II I v r- C I EX. PAINT r I al I ----------------� CCESSIBLE 1 RAMP (TYP.) I 6' WIDE PEDESTRIAN I NX-7-UL - � � � � � X ------------- NF ' III PLANNED PARENTHOOD OF GREATER I� RALEIGH INC 100 S BOYLAN AVE PIN 1703-38-9868 I II DB 4798, PG 489 1 I II 0.47 AC. ZONING: OX-7-UL I 1 11 I I u GENERAL DRIVEWAY NOTE 1. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS -OF -WAY, NOT INCLUDING AN ALLEY. r v ivir — ROOM — — — — 30'x3O' CORNER RETAIL 20'LOT BUILD -TO 20' MAX. BUILD -TO LD-TO MAX. BUILD -TO BUI RETAIL DOOR (TYP.) STAIRS (TYP.) LOBBY —STEPS WITH HANDRAILS LOT 1 36,938 SF t0.848 AC OELEVATORSONING: DX-12-UG & DX-12-UL COMPACTOR LOADING/ REFUSE IVJ IL 43.86' 44 F SEAT WALL— 1- 06 PRIVATE DRAINAGE EASEMENT u• I •STEP$I- • (TYP.yy I� co / j / � ACCESSIBLE j ROUTE (TYP.) SIDEWALK CONCRETE SIDEWALK — / r ACCESSORY STRUCTURE I / 29 L � NORTH BUILDING iva SEAT WALL I 'I 502 SFLOT 3 III 1 / ,' • �I Ifl 1 1 I • • 1 1 II i 1 r1 41,661 1 SF 1 I i I • I • ZONING:9DX AC 11 I 12�F ; 1 26 700'38"w ,,� f I it & DX-12-UL / IilO SEAT j 1 61 LF 1 • I rl "� �� I 1 ' SEAT WALL STEPS WITH p 1, f 7 I 1 / 1 WALL % N HANDRAILS rl (TYP.)49 !•,a I SEATFWALL 59.,30' nl ! I Ill I S7g'55 59 E I / 0' OR BA 3957 SF SEAT WALL 6' BUILDING LOT 2 22 LF ' SIDE LOT LANE / t0.091 AC / DNING: DX-12-UG / & DX-12-UL AMENITY N I `M I I I / (DESIGNED BY OTHERS) o) `r _ 7 .� h 30 LF / 25 N N I ! �. // SEAT WALL j gg.63' W N76-3 30' z �= = J / L // Al 2 33"w I FOR F IIEHAKNOX BOX PREVIOUSLY APPROVED PROJECT / / // / / SEE CITY OF RALEIGH CASE #SR-45-16 Y/ / / //37 / SEATWALL\ / Ar� .4 /� /� I / 9 o 12 LF I` C C / SEAT WALL h � JI %tat S1'52'11"W // 1 — II ACCESSORY STRUCTURE 67.15' / I r 1 I SOUTH BUILDING 2,147 SF y ACCESSIBLE r If 1 11 I I EX. PRIVATE ROUTE (TYP.) I III L — I I DRAINAGE EASEMENT I / 4 J III II soo '11"W �I STEPS WITH ) HANDRAILS (TYP N87'45'337"W --------I�- -�ag.- J 16 LF J GATE WITH KNOX BOX SEAT WALL r FOR FIRE ACCESS 7 ` CROSSWALK (TYP.) I (TYP.) c� F - - - - - - - - - - 7 �_ _ _ _ _ Via_ -{I O 0 30" STANDARD CURB - - - - - - = J Lam_ j C STOP BAR ~ `O AND GUTTER (TYP.) 1PRECAST CONCRETE I I - — - - - - (TYP.) ------ -' N o L — ) — — — — — 1 WALLS TYP. 1 N87'45'37"W EX. CONCRETE EX. BIKE RACK J ACCESSIBLE � — I I 6' WIDE PEDESTRIAN CROSSWALK (TYP.) I 1 TRANS 11 IFORMER GENE RATOR I ZONING LINE (TYP.) DX-12—UG DA-12—UL 0 MIXED —USE ACCESSIBLE - BUILDING ROUTE (TYP.) 264,027 SF STAIRS STEPS WITH — (TYP) HANDRAILS (TYP.) 6 LF SEAT WALL JI W '0•I ORRIDOR • • • �I• 26 LF SEAT WALL . 1 h ",—PUMP • ROOM ACCESSIBLE 1 20.9' - RETAIL ROUTE (TYP.) I — I 30'x30' CORNER LOT BUILD -TO I RI S2'44'48"W 20' MAX. 42.95' YBUILD-TO STEPS WITH I SEATF HANDRAILS • I I WALL _ (TYP.) II I STEPTAPERWITH ACCESSIBLE 19.1, I HANDRAIL ROUTE (TYP.) • I , • I / I- - - - - - - 24.08' N87 ------__--' - '45''37 OA --- BIKE RACK PROPOSED 0 R/W 17 LF vW_=:z3M f SEAT WALL TREE GRATE RAMP (TYP.) 30.79' SIDEWALK (TYP.) _ RETAINING WALL CONCRETE 1- -' V_SA_WnU REMOVE AND (DESIGN BY OTHERS) SIDEWALK REPLAeE-AS REQUIRED FOR UTILITY TIE-IN PER DX-12=UL _ CITY OF RALEIGH FOR HARDSCAPE DETAILS SEE W. 1►1�JJ 1� D G EXISTING DX-7-UL STANDARDS LANDSCAPING PLAN AND DETAIL jv S EX. PAINT ON SHEET D-2 (TYP.) �1�y/11 (VARIABLE WIDTH PUBLIC R/W) SECONDARY STREET _ _ _ _ _ _ — _ (AVENUE 2—LANE DIVIDED) — — — — - — --- ------ ------------y- r==� ---r- -�-_-----_-- I I N/F I I," CROCKER FAMILY PROPERTIES, I ILLC - _ _ _- - - - - - - as 615 W MORGAN ST- I I PIN 1703-48-1885 '' I I DB 1 0.63 , PG AC. 165 fl I I I - - - - - - N/F I ZONING: DX-7-UL 1 I 1 I I RALEIGH HOTEL GROUP, LLC I II 11 I_ I. a I I nl 1-I I I 603 W MORGAN ST HC RAMPS: 1. ALL HC RAMPS TO BE FIELD ADJUSTED WITH INPUT FROM THE CITY OF RALEIGH FIELD INSPECTOR PRIOR TO INSTALLATION. 2. POWER POLES WHICH CONFLICT WITH FIELD LOCATED HC RAMPS ARE TO BE RELOCATED BY APPROPRIATE UTILITY COMPANY. PIN 1703-48-4920 DB 16986, PG 2031 0.23 AC. SEE SHEET C-2 FOR ALL PROJECT, ALL CONSTRUCTION SHALL BE IN ZONING: DX-7-UL SITE, GRADING, STORM DRAINAGE AND ACCORDANCE WITH THE CURRENT CITY UTILITY NOTES OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS HEAVY DUTY ASPHALT PAVEMENT GRAPHIC SCALE q 20 0 10 20 40 1z 1 inch = 20 ft. y 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE PROPERTIES, INC 1 LU lJ rV V z� U W LU m (V M V = z 00 z J �:O< VQor- O =0 = J 0 CO O m z z 0 (D W J U M < N) N v / z O U REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-S1 CHECKED BY CHT DRAWN BY CHT SCALE 1" = 20' DATE 12. 15. 2018 SHEET SITE PLAN C-4 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION v 0 a X HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F N/F L_ II 630 HILLSBOROUGH STREET I 618 HILLSBOROUGH ST I HSA LIMITED PARTNERSHIP THE BAR STOOL INC PIN 1703-49-1348 PIN 1703-49-2349 610 HILLSBOROUGH ST 600 HILLSBOROUGH ST DB 2790, PG 13 PIN 1703-49-3325 DB 4908, PG 342 PIN 1703-49-4345 - - - - - - - o I X DB 16997, PG 1152 EXISTING 0.38 AC. I 0.34 AC. DB 13828, PG 1200 0.30 AC. HIT LSBOROUGH ST. ZONING: NX-7-UL z o 0.18 AC. I II ZONING: NX-7-UL L ZONING: NX-7-UL x x /i // '- ❑E �� - - - I (VARIABLE V ZONING: DX-7-SH ( ABLE WIDTH PUBLIC R/W I 1 Wv W'WTw W- we wc� I c c c c_ -y -i- - _ -_ 35 w w w G�c --;�__-`_ -___�1 __-- _SS SS EX. RCP 8" SS W W- W!w- w / w- w- r_L cLD � G c c c --- L=== ==�1 __-- - f�---- _ --- -� [�}-� ------ ss EX. I�P 8"3SS T 9 W W w W___ � c c c c " c- T� - - - FO F0FO - - ss w- I _ OX-7-UL I �- \ w w W w EX. 8w CIP W/w (ASSUMED LOCATION) o =_ - - - - - %- - - IT � ss _ NX-7-U d ss EX. 8" RCP SS W - L - 3 3 SS W W w \ wv SS -SS W W- / � \ g _ SS ss SS ss 6 \ \ '"-�W- W__w� NX-7-UL� 9 �' ss EX. 8" RCP §S W- w ySS X 12 UG \ ■� I�� I PRECAST CONCRETE / / I _ WALLS TYP. ■� Q3 _ - 9 � 6 - _ _ _ - - - (DESIGN BY OTHERS) �� T - i�S / LIMITS OF PROPOSED Fl� # 5 - �\ 4 LD �D - DISTURBANCE - - g LD - IE LD LD I / T I ` - _ 3n 3n LD LD LD I 6 `� �I I I Ir--------=__-- - \\ AREA DRAIN--- / ( III PI I P:353.8 --- --� - - = = - (TYP.) II I I I I _E353.8- `� Z - ------ \ I _ I-�� 31 I r -I---- i - I-�- _-- - ✓ \� 353.97 � � V 52 90 � I 3 353.30 353.30 >• \ 353.97 353.97 353.97 I v Y - - - - - - _ - I 3 I 1 - 352.97 - - I / I I�,p O�-• I �„ FFE- I I 1 20' WAX. � - 33 353.97 I BUILD -TO I ^I \ J 3 I P:352.00 LIMITS OF I I / \ 35.97 I ' / E:351.30 1 I JI DISTU E 352 97 29 O I FIRE RETAIL 8" Pvc 1 �i I 352.05 '� �I i I I 30'x3O' CORNEE i DTT1fD FFF=1152.97 STORMz�_ I; ^1 I Z o I I N/F I 1 J I FMW AT 701 HILLSB ROUGH LLC R 701 HILLSBO O GH ST ( it PIN 1703- 0106 ' - - I � I DB 16937, 2509 Z --+ I ) / N BM 1987, 12 1251 0.43 L u N I J ZONING: X II I (� w I 353�97 II II I I I I\ 7 I� I I I X o I I/ \ I � I I I N I I I 0& �� • C ISTEPI �I j" - � HANDSf�,ILSH I (PROP 0SE$ TLTTl7R €--F'RO-J EE & I I/ REFERENCE ONLY ASSUMED 100� IMPERVIOUS) I I I I I \ TRANSACTIONS 573539 11 I II II I �I I 352.8 CASE # SR-100-18 I II I IN � II 352.8C \ \ I II I 352.80 \ \ I I II 352.80 I 352.80 - RIM=3- V \ I 8"VCP(S)- 46.01 II • I,� I 352.0- �OSED 352.00\ ip 11 17 II- i �I Ip� DUI I I ^ 51.97 - 3 700 WESTNMORGAN LLC I I ICI II I 0I 00 I PIN 1703-49-0004 a x DB 11755, PG 933 I II \oo ``' / 9 0.15 AC. ZONING: NX-7-UL + mil II x l x I I IIDI�t III �o �IF- EX. CB J TOP=351.99 12"RCP(E)=349.47 I I v / x -T----�--- ----� I W o \ \ \ EX. C� \ � � � \ TOP=35Z. 6 \ \ \ \ � 12"RCP(E)=-3W_40 53 \ \ 1 W Wv \ NX-7-UL I I II w w w OX-7-UL - 7SSMH I / / RI"�352.57 I ZEE&__VCP(N)=344.38 8'VCP(S)=344.26' ou ou I -----=_--- no no flo \1 n0 \ I / NF PLANNED PARENTHOOD OF GREATER RALEIGH INC 100 S BOYLAN AVE PIN 1703 38 9868 DB 4798, PG 489 I r B 0.47 AC. ZONING: OX-7-UL RETAIALL =IGN�BYV OTHE,� EX. JB �/ (ASSUMED 18LOCATION) RIM=352.17 RIM- 50.40 I LIMITS OFF 18"RCPO=349.34 INV IN(N)=346.41 DISTURB NCE 12"RCPAW)=349.46 INV OUT=346.41 / (TYP.) 12"RCf(NW)=359.58Ij FCO 013 ang KIM=J4 Jy EX. SSMH INV I ( )=338.79 RIM/345.38 1 CP(W)=338.79 8"VCP(E)=338.23 I RCP(E)=338.79 - - - SS -EX. 8" DIP SS SS SS __ 6 p I I EXISTING - - -� d I W.®���� cT• EX. SSMH / PPP I I (VARIABLE IJ I ! RIM �43 25- 3#4/ IIII r i I ( BLE WIDTH PUBLIC R/yv) f \ ,8 DIP(E)=333.06 8"DIP(W)=334.74 N/F l / 10"DIP(16"ENCASEMENT) I il' I I CROCKER FAMILY PROPERTIES, LLC I j \ (S)=333.05 MORGAN 11 PIN 1703-48-1885 / DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL 15"RCP(S)=337.27 / EX. JB-1 13 RIM=342.90 15"RCP(N)=336.93 15"RCP(W)=336.93 15"RCP(E)- 36.93 _-- - - - 8" IP _L _ �A I 101 344 L I- I ' STEPS WITH LOT 3 r r -j y� (TMP) AILS 41,611 SIF a- t0.955 AC =_ 6 ZONING: DX-12-UG� I r & DX-12-UL AREA DRAIN r� (TYP.) 0' OR 6' BUILDING SETBACK FROM J1 8" PVC STORM T SERVICE PRIVATE DRAINAGE EASEMENT a rr4 � S " al I II ACCESSORYSTRUCTUREII SOUTH BUILDING Ii FFE=346.79 EX. PRIVATE DRAINAGE EASEMENT EX. SSMH RIM=343.38 8"DIP(E)=334 27 PREVIOUSLY APPROVED PROJECT SEE CITY OF RALEIGH CASE #SR-45-16 8"DIP(S)=334.27 r r - - - -I- -\-/ 0 - - i ram, ---•FPS as __ � _ _ EX. /CB-110 - L T/q=345.37 / 15' RCP(E)=339.17 N a w��w"RCP(W)w 339.07 w / EX. JB-106 a52RIM=343.07 1i RCP(NE)=3366 °° ^� 15" RCP(E)=336A 6 �I > w I 15" RCP(W)=336.16 12" PVC(NW)=339.21 18" RCP(S)=336.06 EX. SSMH SS RIM=342.98 8"DIP(N)=333.68 r - - 8"DIP(W)=3 3.48 as - - - -SSSSp� SS SS M�� SS I I I I N/F I RALEIGH HOTEL GROUP, LLC - - . _ I- - - - 603 W MORGAN ST PIN 1703-48-4920 DB 16986, PG 2031 0.23 AC. ZONING: DX-7-UL r J/ / / / / -sow so e - - -' r\ / SP SS/ n GRADING LEGEND CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN O JUNCTION BOX ��--- DRAINAGE FLOW ARROW 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION P-250.00 PROPOSED AVERGAGE GRADE PLANE SPOT E:248.00 EXISTING AVERGAGE GRADE PLANE SPOT STORM DRAINAGE STORM SERVICE LINE LD LD LIMITS OF DISTURBANCE 250 MAJOR CONTOUR 252 MINOR CONTOUR ------_ 250 EXISTING MAJOR CONTOUR ------- 252------- EXISTING MINOR CONTOUR EASEMENT LINE SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. DISTURBED AREA = 2.00 AC. EX. CB-117 T/C=343.17 INV IN=338.41 (JB-117A) INV OUT=338.31 JB-117A RIM=344.90 INV IN=338.80 (JB-117B) INV OUT=338.70 JB-117B RIM=349.75 INV IN=339.35 (SWMF) INV OUT=339.25 SWMF RIM=349.50 INV OUT=339.50 SWMF RIM=349.50 INV IN=346.10 (JB-200) JB-200 RIM=349.50 INV OUT=346.50 GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE PROPERTIES, INC W z� U W W M ^ I..L F �0 I (A N M V = z 00 z 0 J �OU Z) = VQor- O °COF- = J 0 m O m z z 0 (D LU U M < N�N N Ln z O U 0%uuu 0%% �\A CA, ••�� - WO& . S. SLP.•`��,, REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-G1 CHECKED BY CHT DRAWN BY CHT SCALE 1" = 20' DATE 12. 15. 2018 SHEET GRADING PLAN C-s PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F N/F ' I 630 HILLSBOROUGH STREET 618 HILLSBOROUGH ST I HSA LIMITED PARTNERSHIP I THE BAR STOOL INC ' PIN 1703-49-2349 610 HILLSBOROUGH ST 600 HILLSBOROUGH ST I- II / PIN 1703-49-1348 DB 2790, PG 13 PIN 1703-49-3325 II Ii DB 16997, PG 1152 I EXISTING 0.38 AC. I PIN 1703-49-4345 EX. FIRE 0.30 AC. DB 40.34 AC. 342 DB 13828, PG 1200 I � ZONING: NX-7-UL HILLSBOROUGH pT ZONING: NX-7-UL I 0.18 AC. SS 0 / \ HYDRANT 1 Y 1 �� S ®� ®U u Cy m • ZONING. NX-7-UL ZONING: DX-7-SH E I 1 � �7 1 (VARIABLE WIDTH PUBLIC R/W I I I -G- mac- I •--c�j-----_-� V --` _ _ --- --- _ �- I c -W�ry�W W�WG WG w n�--G W W w G G \ RCP W W- c -ss ; EX. SS w�W_ w---� -, G- G G ss 3 ss �- Ss ss __ _ 18"X8W H-304 SS TS&V W G N _EX- 8w CIP W/L (ASSUMED LOCATION) - �o - _ _ _ _ _ _ - _ - _ i 1(- -�- - r - - - I I� � I i � EX. 8" RCP SS W W W W yy W � W � � sD 3 ; s SS I L W W W__ W� _ W EX. SSMH I I SS SS W -W�W� I RIM=355.14 IRRIGATION WATERLINE BACKFLOW DEVICES SSs- SS - - W wWv - 8"VCP(N)=348.98 SAWCUT REMOVE AND I I 8" DIP FIRE PROTECTION WILL BE LOCATED IN THE BUILDING. I I ISS ss W 3 8"VCP(E)=348.61 3 0� REPLACE AS REQUIRED I I SERVICE COORDINATE WITH PLUMBING PLANS FOR ss 8"VCP(W)=348.73 FOR UTILITY TIE-IN PER MORE INFORMATION. BACKFLOW DEVICES SAWCUT REMOVE AND I I ss - CITY OF RALEIGH I I 1" COPPER IRRIGATION SHALL BE A 1" WATTS LF909QT (RP) OR REPLACE AS REQUIRED 0 3 / STANDARDS I I SERVICE LINE APPROVED EQUIVALENT. FOR OFLITY TIE-IN PECITYR 1" IRRIGATION FIRE WATERLINE BACKFLOW DEVICES STANDARDS I I 4" SS SERVICE \ 8"X4" TEE I METER WILL BE LOCATED IN THE BUILDING. _ _ -- - FIRE HYDRANT I FIRE COORDINATE WITH PLUMBING PLANS I I -� 7¢( - - _ ; \ _ - - - -ASSEMBLY (IYP.) DEPARTMENT FOR MORE INFORMATION. BACKFLOW I a - I 2" COPPER DOMESTIC I I O - - CONNECTION DEVICES SHALL BE A 8" WATTS LF909 OR APPROVED EQUIVALENT. SERVICES I I 00 I w SIT '4�-vALVE------------------I I I OT L _ - I 4" METER an 3n - �lo' AND VAULT n � -3 8" GATE VALVE 2_ " GV 4" GATE VALVE _ _ - - - - _ - PROPOSED 2" METER I I I I 4" DIP DOMESTIC - - -L _ - - - - - - - R/W \ I - - ---- AND VAULT_ • ram\ TER SERVICE _ EX. WATER J I Ilo 3 ` I I � - - - - - _ � - z _ 1 -i - �� - 2" GV METER � ��\\� I W I ~ I I I I I II I I I I 20' -MAX. ILD-TO PRIVATE E DRAINAGE FFE_BUCLEANOYUT _ I I`I - ET-�-0 EASEMENT 3.-° L 353.97 TYP.Ex. 4" W/L RETAIL �30'x30' CORNER FIRE F=352.97 LOT BUILD -TO PUMP DOMESTIC WATERLINE BACKFLOW DEVICES WILL BE LOCATED IN THE BUILDING. COORDINATE WITH ACCESSORY STRUCTURE PLUMBING PLANS FOR MORE IilO I NORTH BUILDING RETAIL INFORMATION. BACKFLOW DEVICES FFE=352.05 Illl I FFE=353.97 SHALL BE A 4" WATTS LF909 (RP) / I I I FMW AT 701 HI L B ROUGH LLC I II I I I OR APPROVED EQUIVALENT.`i EX. 8" W/L III I 1 S R I AIRS 701 HILLSBORO GH ST ' 13 I � " LIM08in0 WMIRBE" OINIC FIRE HYDRANT ASSEMBLY FIRE DEPARTMENT CONNECTION 0 WATER METER N WATER VALVE POST INDICATOR VALVE N ® VALVE IN MANHOLE METER & VAULT © BACKFLOW PREVENTER REDUCER u PLUG o_I+- BLOW -OFF ASSEMBLY • SANITARY SEWER MANHOLE • SEWER CLEAN -OUT m GREASE TRAP SEWER FLOW DIRECTION / ARROW T YARD LIGHTS LIGHT POLE POWER POLE r.. LINE BREAK SYMBOL WATERLINE WATER SERVICE LINE ----------------- UTILITY SLEEVE SANITARY SEWER SEWER SERVICE LINE FM FM SEWER FORCE MAIN -G-G-G-G- GAS LINE OU OU OVERHEAD UTILITY PIN 1703-45 161i - DB 16937, P 25o9 I STORMWATER I I I I I I 11 41,0611 SF Ifl i I UE UE UNDERGROUND ELECTRIC BM 1987, P 1 1 T I 20 CONTROL MAX. �/ t0.955 AC 1 I II I I 0.43 A Ri � � I I BUILD -TO I I I 3 , ZONING: DX-12-UG I �-T-T-T-T- TELEPHONE ZONING: NX7-UL W I MEASURE A ; I I & DX-12-uL Ifl I I a I I I (SEE "SW" SHEET) 1 E I li = _ = III i 1 I - - - - EASEMENT LINE / I I STEPS WITH I II CLEANOUT 3 I , 1 TYp, I 1 HANDRAILS II \ z a I I I I I I LOBBY -- I 11_ I� I I SEE SHEET C-2 FOR ALL PROJECT, I ��x I I �� '-' I � � � I � FFE=353.30 � - _ �� � i I 1� M � � Io4 I I SITE, GRADING, STORM DRAINAGE AND I \ `� Q I I L _ - I III I'I I UTILITY NOTES I \ I I I LOT 1 STEPS WITH 3 F / I I II 1 � � � � " I 36,938 SF HANDRAILS t AC / 4" SS 3 I 0' OR 6' BUILDING K FROM�_� II I - - - - - - I I t0.848 AC (TYP.) ZONIN-12-UG/ SERVICE ( SIDE L LOT LANE Ifl I I I� ALL CONSTRUCTION SHALL BE IN I I I I I I ELEVATORS ZONING: DX-12-UG 12-UL / 1 lil I III I ACCORDANCE WITH THE CURRENT CITY & DX-12-UL / I I a I I OF RALEIGH ENGINEERING DESIGN AND I COMPACTOR I �I PROPOSED FUTURE PROJECT SITE REFERENCE ONLY LOADI \ (ASSUMED 100% IMPERVIOUS) I I I REFUSE L TRANSACTION# 573539 I II I I FFE=352.80 IM II I CASE # SR-100-18 II � I II I I I ram` I i III I GENE TRAN FORMER RATOR FFE 352.80 I I h II I I FE-_ 352.8C _ _ CSC. SSMH I I RIM=353.13 I I G 3,000 GAL GREASE INTERCEPTOR (DESIGNED AND PRIVATE DRAINAGE ROUTED TO SERVICE EASEMENT BY OTHERS) / I/ RETAIL FFE=349.80 O I MIXED -USE I / BUILDING STEPS WITH NDRILS 8 VCP(3)-346.01 I z• DOM P.) / II I PUM II ca> o I I FFE=35 .80 1 STAIRS I I I II0 12 I ( I I RR R TYP.) -- - - - =U P II N I PROPOSED" I I FIRE I I R/W I PUMP -I LI I I II J R I I FFE=352.80 RETAIL II I I P II 31 a I o I I =349.80 FFE RETAIL I FFEI II I I FIRE WATERLINE BACKFLOW DEVICES I N/F II tO o0� 1 I � II " I I WILL BE LOCATED IN THE BUILDING. I 700 WEST MORGAN LLC X X COORDINATE WITH PLUMBING PLANS PIN 1703-49-0004 FOR MORE INFORMATION. BACKFLOW 20' MAX. I I DB 11755, PG 933 I I I DEVICES SHALL BE A 8" WATTS LF909 BUILD -TO STEPS WITH 0.15 AC. IIIloIlIlI •I I �, II I1 II (RP) OR APPROVED D EQUIVALENT. HANDRA ILS ZONING: NX-7-UL CLEANOUT (TYP.) CORNER FIRE HYDRANT L30 0T3B0U_III I II ~I I I I TYP. ASSEMBLY I II ( > �� II -ill I L 8" SS SERVICE - - - - - - - - - - _ I I PROPOSED --- -- - --- I / 9i I ` I I R/W CLEANOUT ono- nc ---- �a • I ------ -____ I - G S so F SD - FIRE Wv o eDEPARTI CONNECM ENT ON RETAINING WALL • W wT I I I I - - - - - - - - - = EX. 8" CIP W/L (DESIGN BY OTHERS) I I o L--- " ----H - 8 DIP FIRE PROTECTION 7ASSIdi L.-MATI10i - - - - - - - - - - - - - 0 SERVICE - - SSMH I 4" SS SERVICE STUBBED EX. RIM SSMH 7 • 8"X8" H-304 SS TS&V AT CLEANOUTS FOR FUTURE D ING SERVICE SAWCUT REMOVE AND 8"VCP(N)=344.38 I o AND GREASE CONNECTIONS 8"VCP(S)-344.26 � I '' REPLACE AS REQUIRED EX. SSMH - - _ - - - - - - - _ 3 I FOR UTILITY TIE-IN PER RIM=345.38 w CITY OF RALEIGH 8"VCP(E)=338.23 ou Gu I Y� STANDARDS - - - - - - - - - no nono Z = -----_---------- ��EX. 8" DIP SS - - \\ - __ o f _ R_ nc_ �c-� SS -SS no FO - no F0- no _ _ z 111 - _ _ _ _ -- Ir D� I I EXISTING - - - II I EX. FIRE I II a W• MORGAN ST. N/F HYDRANT �I II81 Iji (VARIABLE WIDTH PUBLIC R W PLANNED PARENTHOOD OF GREATER II o_ I / ) S + RALEIGH INC I II 010I� II I �1;� I rl 1 I 100 S BOYLAN AVE I I x 11 1 'I N/F PIN 1703-38-9868 II w I I CROCKER FAMILY PROPERMES, LLC DB 4798, PG 489 I 615 W MORGAN ST 0.47 AC. PIN 1703-48-1885 ZONING: OX-7-UL DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL CLEANOUT CONSTRUCTION STANDARDS / I � - I III / TYP. I - MM,-_ J� I III / i I Il I I 4' GATE WITH KNOX BOX � FOR FIRE ACCESS L II \ I PREVIOUSLY APPROVED PROJECT / SEE CITY OF RALEIGH // / CASE #SR-45-16 � r ° EX. 4" W/L / % ACCESSORY STRUCTURE SOUTH BUILDING FFE=346.79 All L/E STORM DRAINAGEEASEMENTIIIL I I F al EX. 8" IW/L h� o II ► II � � / // / % � -'q i r.3 V.-I _ _ J/j / Iv SS -� SS SS _ _ _ _ _ _ 7- - I GRAPHIC SCALE J O ° c� I 20 0 10 20 40 -+4- M EX. 8" W/L /// �\ �\ --�-- WV -b - - - Mfl�r}i-M M �1 1 inch = 20 ft. 7 So GS GS- -M �` -�- _ - - �l / SD - SD \ . GATE WITH KNOX BOX �! FOR FIRE ACCESS �w o EX. FIRE W W W HYDRANT / 4" SS SERVICE - 1,000 GAL COMMUNITY GREASE INTERCEPTOR (BY OTHERS) STEPS WITH HANDRAILS (TYP.) r SSMH 2" GV 8" DIP SS -2 . GV 72�" 'SDMETERsilD VAULT Wv I., OlW WW_ If - J EX. SSMH RIM=343.25 8"DIP(E)=333.06 8"DIP(W)=334.74 10"DIP(16"ENCASEMENT) (S)=333.05 EX. 8" DIP SS SS e< a I 0 EX. SSMH 00 RIM=343.38 w V 8"DIP(E)=334.27 11 8 DIP(S)=334.27 I EX. PRIVATE SEWER TO BE CONVERTED TO PUBLIC SEWER EX. SSMH RIM=342.98 _ 8"DIP(N)=333.68 �s 8»DIP(W)=333.48- Ip cis - Gs' -� so SS I I N/F I ------ RALEIGH HOTEL GROUP, LLC 603 W MORGAN ST NOTE IRRIGATION CONTRACTOR SHALL NOT MAKE ANY ADDITIONAL TAPS ON THE PUBLIC WATER SIDE OF THE IRRIGATION SERVICE BACK FLOW PREVENTER. ALL PRIVATE IRRIGATION LINES AND TAPS SHALL OCCUR ON THE SERVICE SIDE OF THE BACKFLOW PREVENTER TO PREVENT ANY UNPROTECTED TAPS. PIN 1703-48-4920 DB 16986, PG 2031 0.23 AC. ZONING: DX-7-UL C) 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 y HERITAGE a" PROPERTIES, INC ,,W lJ (V V z� U W W M M V = z 00 z (D J �:O< VQCC- O °COS = J 0 CO 0 m z z OLill JT J U ZN) M < N (ri z O U "'0%J11n1 RL-1 _ = 9 r; • S. S\jP .:,,� 1111111100. REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-U1 CHECKED BY CHT DRAWN BY CHT SCALE 1" = 20' DATE 12. 15. 2018 SHEET UTILITY PLAN C-6 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION L_ II G G \ w WG ss � ss SS _SS 3 � N/F Temporary Skimmer Basin Design Table I HILLSBOROUGH 630 LLC N/F I N/F /I 630 HILLSBOROUGH STREET I AYCOCK, MAHLON L WILDER, RYON W HSA LIMITED PARTNERSHIP Sediment Trap ID SB-1 PIN 1703-49-1348 618 HILLSBOROUGH ST 610 HILLSBOROUGH ST N/F DB 16997, PG 1152 EXISTING PIN 1703-49-2349 I THE BAR STOOL INC Drainage Area (AC.) 0.90 l PIN 1703-49-3325 600 HILLSBOROUGH ST Flow Q10 (CFS) 5.84 EX. FIRE 0.30 AC. I DB 2790, PG 13 DB 4908, PG 342 PIN _ 49-4345 HYDRANT HILLSROROUGH ST. ZONING: 8NXC7-UL 0.34 AC. j DB 1 828, PG 1200 Bottom Elevation (FT) 339 ZONING: NX-7-UL I ZONING: NX-7-UL SAWCUT REMOVE AND ■ (VARIABLE WIDTH PUBLIC R/W) EX. VARIABLE WIDTH REPLACE AS REQUIRED 0.18 AC. _ - - _ J -__ _ PUBLIC R/W - PER' ZONING: DX-7-SH Sediment Depth (FT) 2.50 _ - _ FOR UTILITY TIE-IN __ �l Dd _ �y - - - STANDARDSTY OF Depth Freeboard (From Sediment Depth) 1.50 w wW W\� -�-= -_--mac - ---- --- ----�__--- --- _ DepthtoCrest ofRiser gFT) N/A �W EX. GAS LINE -1_ \` a W- W--_ W- \ c- c G c- {{p11- LE}- Fc FG De th to Crest of Emer ency Spillway (FT) 4 ;S SSG - SS SS SMS TSs _SS LIMITS OF \ EX. 8" CIP W/L (ASSUMED LOCATION) o _ _ _ # _ __ �� Side Slope 2 OH 1 OV \ SS ss ss -DISIURWCE^ - w 1D wv r�� - - - - Spillway Length (FT) 6.25 (Riser Circumference) ss sr EX.Sg " SS _ \ W EX. 8"w L - \ Height of Berm (FT) 4 IEX. SSMH "I"Mm 9 CONTRACTOR TO FIELD ; _ SS SS SS SS ss 6 �W Top of Trap Length (FT) 52 RIM=355.14 �� -�-� ATER SERVICE TO-BI- 9 F� ss 8"VCP N-348.98 ` OCATIRV OF DISCONNECTED AT THE MAIN PER CITY ss Top of Trap Width (FT) 34 ( )- EX. WATER SERVICE ss 8"VCP(E)=348.61 ` T DEMO AND�REMO _ _ _ - -�� RALEIGH STANDARDS. IN LIEU OF / 0 ARR - SAWCUTTING ACROSS ROAD, POTHOLE �� Storage Volume Required (FT) 1620 8"VCP(W)=348.73 EXISTING P KING EA - 9 INCLUDING EXISTINCONNECTION;.: DISCONNECT THE SERVICE � G / ' Storage Volume Provided (FT) 2380 ` PAVEMENTWALLS, AT THE MAIN, AND FILL ENTIRE TQ 3 , 6 - ABANDONED SERVICE WITH FLOAWABLE LIMITS OF 9 \SIDEWALKS, C RB AN/� -- --; DISTURBANCE Sediment Surface Area Required (FT) 1270 S .GUTTER, PAINT STRIPE UNDERGROUND �, FILL PER RALEIGH STANDARDS. (TYP.) - 3 - Sediment Surface Area Provided(FT) 1290 LIGHT POLES, 0 ELECTRICAL EX. ELECTRICAL 9 - - / AND FENCES � SAWCIJfi-ftN�f2EPLACE EXISTI)1� - - 6 co 5+- - AN �p ID II REMAIN- VAULT AND LIGHT CURB AND PAVEMENT. GRANITE _ - Number of Skimmers 1 LD J _ POLE TO REMAIN _ s CURB TO BE SALVAGED AND T9 w Skimmer Size (IN) 2 }�D e $ R _ - LD LD REMAIN IF POSSIBLE. -- SILT FENCE EX. ELECTRICAL SF SF = - LD ID TMp• Skimmer Orifice Size (IN) 1 - - - 9 � sF--� ^, _ _ - - - - - VAULT TO REMAIN SF F - I LD ! EX. PAINT TO B � / - -3n -- -----� sF S �---- � Ant -Flotation Block SEE SIA L _ 6 REMOVED '� - �'- LD 6 L: -�- �_ 3n - "gal - -3n �n- - ��- I �sF= _ Riser Diameter (IN) 24 - ----- - �' - _ Barrel Diameter(IN) 15 I I I EX. ;GAS E ICI I I I EX. WATER METER - - - - - - - = z g \ III TO EM U�1 I I- - TO BE REMOVED - - - - - - - - - - Notes: I iX. GRANITE CURB TO BE / I i I I --- � '"------I 1 � � EX. WATER vv3s 1. SIDE SLOPES PERTAIN ONLY FOR THE VERTICAL HEIGHT FROM I REMOVED AND REPLACED -JI I I 1 1 -I I ---I METER \� I � ( WITH LIKE MATERIAL � I 9 � � I .� _ \ THE BASE TO THE TOP OF THE BERM. I / / I I I III II SILT FENCE OUTLET AT I �`� 2. SEE DETAIL ON SILT FENCE AND BAFFLE SPACING. 3 I ALL LOW POINTS (TYP.) DEMO AND I DEMO AND REMOVE I e`- EROSION CONTROL LEGEND I I EXISTING PAVEMENT �� I /. � 9 I SILT FENCE SIL'1ENCE OUTLET AT REMOVE EXISTING I II I (TYP.) / ALL LOW,POINTS TYP.Z_ 2-STORY BUILDING I CURBCONCRAND GUTTER SILLIMITST II I I Illlllllli SILT FENCE OUTLET -SF -SF -SF - I \� I � I �I DISTU 0 E I I I -II / i U-TP-TP-TP- SILT FENCE f I I ® hh TREE PROTECTION FENCE � II 11(�'> �I 91 III ' - I PROPERTY LINE EX. BOLLARDS, n 3 I II I I I I _ - PROPERTY ABANDONED TO BE ABANDONED ELECTRTELEPHICAL ANDONE BOXES I I II I N F INLET PROTECTION LD LD � I � I � I TO BE REMOVED I II 3 1 LIMITS OF DISTURBANCE L - yI I I I I GLENWOOD GLENWOOD FFAVE LLC INLET PROTECTION WOODED AREA N/F / E-' ICI I I - # -' TEMP. GRAVEL CONSTRUCTION I I I PIN 1703-49-4101 FOR EXISTING STRUCTURES FMW AT 701, HILLSBOROUGH LLC ��,� I I I I I N/F I I I _ ENTRANCE/EXIT II f I DB 16926, PG 570 ����� DIVERSION DITCH Q 701 H�L,LSBOROUGH ST ( QQ I � GLENWOOD TWO LLC 0.70 AC. PIN 1'03-49-0106 _ ^,' ++ir IEX• W M R N I 623 HILLSBOROUGH ST I I PVALLAS ARTNERSHIP LTD II I ' I I ZONING: DX-12-UG, DX-12-UL TEMPORARY SLOPE DRAIN ° o°�Q°� o o°,Q°� DB 1 37, PG 2509 �J TO BE R MO 1- -< j� -�� PIN 1703-49-1158 I o�v °' °­°d BM 87� PG 1251 I I 111 �� ° I DB 17043, PG 1871 I 621 HILLSBOROUGH ST II I I I I I I o° °� o °° o° �o U° 0.28 AC. I ° ° CONSTRUCTION ENTRANCE/EXIT DEMO AND o o 0 .43 AC. I a % I % ° \ ZONING: DX-12-UG I PIN 1703-49-2128 I REMOVE EXISTING - I / 3 vO o" ° o° vO O" ° ZOM NX-7-UL I I I DB 6218, PG 552 I II \ FILTER BERM o uO�� - ° I I i -2=STORY BUILDING - - -- - / °° °� o �° 0-4 /� - ° - I ZONING: DX 12-UG II, - I II ° ° _ o0 0 ° ° ° PROPOSED F U E PROJECT SITE R N E ONLY ' I IIIII� I II I III II 'I I I I VARIABLE WIDTH II I I III I I I I I 3I 6G y� D bL`TICHECK DAM DRAINAGE EASEMENTDEMO AND TO BE ABANDONEDREMOVE EXISTI350ASSUMEOIMPERVIOUS N +_M DEMOLITION LEGEND ATI 1-STORY BRICKTRANSBUILDING DEMO AND REMOVE - XIS CONSTRUC�ION ETINGRAVEL PARKING /CASE S ENTRANCE/EXITUG EXISTING ING UNDERGR OU ND UTILITY DUMPSTERPAD, TO BE REMOVED EX. WATER SERVI E TO BE SIDEWALKS, CURB AND I I I / I 'I DISCONNECTED AT THE MAIN PER � III GUTTER, LIGHT POLES, II I II I I - LIMITS AREA BE REMOVED OF RALEIGH STANDAFDS. IN LIEU OF °� CLEANOUTS, AND FENCES DISTURBANCE A D GUTTER, SAWCUTTING ACROSS\ ROAD, POTHOLE � (TYP-) ASPHALT, CONCRETE CONNECTION, DISCONN CT THE SERVICE PROPERTY LINE PAVING, ETC.)AT THE MAIN, AND FILL -,ENTIRE I TO BE ABANDONED ABANDONED SERVICE WITH ABLE EX. AC U ITSW T-FILL PER RALEIGH STANDARDS. I I I / / 11 I BE REMED NOTE: SEE PLAN FOR DETAILED DEMOLITION PROCEDURES, jv= SEQUENCING AND SPECIFICATIONS. PROPERTY LINE I CONSTRUCTION SEQUENCE - STAGE 1 EX. POWER POLE AND 9 / �� \ TO BE ABANDONED I L J I �\ OVERHEAD POWER TO B ( I / - - ' / / /I J R E I I / - - - 1 EX. OVERHEAD �� \ 4 �`� 1. OBTAIN A LAND DISTURBING PERMIT. REMOVED OR RELOCATED A \ I II I I ' /// _ _ _ -� \ ELECTRICAI TO / / / I I / NEEDED. CONTRACTOR TOLL-- I II I -�X- - BE REMOVED / / / I --��� \ //� 1i PREVIOUSLY APPROVED PROJECT 2, SUBMIT DOCUMENTATION REQUIRED UNDER THE SITE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITY COORDINATE W/ APPROPR TE I I - - - = - �! (TYP.) 6 / % N/F SEE CITY OF RALEIGH (NCGO10000) TO STORMWATER INSPECTIONS THROUGHOUT THE PROJECT. UTILITY COMPANY I \ I II I 9 - .rr• � r -\' / C61V5 HILLSBOROUGH GH ST CASE #SR-45-16 �. / PIN 1703-49-2196 \ � / � ° 3. PRIOR TO BEGINNING CONSTRUCTION CALL THE STORMWATER INSPECTIONS REGIONAL COORDINATOR AT \ EX. SSMH II II I I I EX. STAIRS TO BE I I �% / DB 11575, PG 881 \ /�I T - �j��° N= 7% L (919)-279-1308 TO SCHEDULE AN ON -SITE PRE CONSTRUCTION MEETING. \ RIM-353.13 II j - - - REMOVED 0.® ZONING:49 AC.DX12-UG ` I ' STORM DRAINA TO BE "VCP(S)=346.01 * ^ I9 I -�-- - - - - � I � � I L - 4. INSTALL ALL PERIMETER SILT FENCE AND INLET PROTECTION, AS SHOWN ON THIS SHEET, PRIOR TO BEGINNING I - - - , ` \ DX-12REMOVED OR ABANDQ IN \ \ I I DEMO AND REMOVE trT - - - - - �_ __- - - - I _ - - J PLACE AND FILLED DEMOLITION OF EXISTING GRAVEL, CONCRETE, STRUCTURES, ETC. EXISTING BRICK BUILDING I rr - \ / I FLOWABLE FILL. X \ I II AND PARKING DECK I / I % _ _ - - EX. LIGHT POLE I TEMPORARY INLET �` 5. CALL THE RAPID RESPONSE NUMBER (919) 857 4412 TO SCHEDULE A STORMWATER SITE INSPECTION. INCLUDING EXISTING I TO BE REMOVED "� `'' I - I / _ ' \9 • PAVEMENT, PARKING KIOSK, I I TEMPORARY CHECK - -- I ' PROTECTION (TYP.) \\ 6. UPON APPROVAL OF STORMWATER INSPECTION COMMENCE WITH THE PERMITTED LAND DISTURBING ACTIVITY SIDEWALKS, CURB AND (TYP-) I �'AM (TYP.) /"ti OUTLINED BELOW. \ I GUTTER, LIGHT POLES, AND �j TEMPORARY INLET CLEANOUTS N/F PROTECTION (TYP.) I L 34 X. WALL TO BED 1 7. BEGIN DEMOLITION OF ALL SITE FEATURES REQUIRED TO INSTALL THE TEMPORARY SEDIMENT BASIN SB-1. o GLENWOOD TWO LLC EX. DI EX. UNDERGROUND I- -- -- -- -- REMOVED � / II II e- I II 11 S BOYLAN AVE GRATE=343.53 ELECTRICAL TO BE I I TEMPORARY CHECK I �� 8. INSTALL SEDIMENT BASIN SB-1 AS SHOWN ON THESE PLANS. II U I PIN 1703-49-1076 12 RCP(E)=342.65 REMOVED (TYP.) PROPERTY LINE DAM (TYP.) I 3 of I I DB 17043, PG,�1865 TO BE REMOVED I I 4rr / 1 `� I 11 0.39 AC. TO "BE ABANDONED! I �/ 9. PRIOR TO COMMENCING ADDITIONAL GRADING AND DEMOLITION OPERATIONS FOR THE SITE, CALL 919-857-4412 >;I ll I �t J !r N I� ., ZONING: DX-12-UL L1 Ll EX. DI I - -346- I J I II W FOR AN INSPECTION OF THE TEMPORARY SEDIMENT BASIN, IF APPROVED COMMENCE WITH ADDITIONAL STEPS IN I -I / GRATE=343.47 I I STAGE 1. III V) �- - 1 TEMPORARY DIVERSION ? 12"RCP(S)=340.56 I I I' 17 g� 8 DITCH/BERM. (TYP.) W. 12"RCP(W)=340.56I I I TEf�PORARY DITCH TD-2 LINED WITH II + - �- - - - - - - I TO BE REMOVED �3 r NAG ERONEr ITCH OR EQUIVALENT. 10. BEGIN DEMOLITION OF REMAINING SITE FEATURES SITE AS SHOWN ON THIS PLAN AND THE DEMOLITION PLAN ' I I ' I I - - - - - - - - - - - - - I \ TEM ORA 18 ASSOCIATED WITH THIS PLAN SET. IIII I 3 I I -► I I TEMPORARY H K I s` HPP SLOPE D I 1 II a � I I I I - �►��CHECK '�,�, / r- =d ) I 11. GROUND COVER SHALL BE PROVIDED AS FOLLOWS: 700 WESTNMORGAN LLC PUBLIC RIR�W WIDTH I II II I I (- - J ��►��.��� DAM (TYP.) i I L I I i i I II FOR ALL AREAS OF MODERATE AND/OR STEEP SLOPES, PROVIDE TEMPORARY GROUND COVER IF THE SLOPE PIN 1703-49-0004 I I I� II I x I X Ipp I I TEMPORARY DITCH TD-1 LINED WITH �'����►� I- - 34 __ - - - I I 11 HAS NOT BEEN DISTURBED FOR A PERIOD OF FOURTEEN (14) DAYS. DB 11755, PG 933 I J II \w w I r I I NAG ERONET C125 OR EQUIVALENT. TEMPORARY CHECK DAM EX. PAINT TO BE COIR'BAFFLES (TYP.) �I�! I I L SB-1 • PROVIDE GROUND COVER SUFFICIENT TO RESTRAIN EROSION ON ANY PORTION OF THE SITE UPON WHICH 0.15 AC. REMOVED I I EX. GAS LINE (ASSUMED (TYP.) ZONING: NX-7-UL I I I LOCATION) TO REMAIN. I \\� (SEE BASIN DETAIL FORI I II(SEE SUMMARY TABLE) FURTHER LAND -DISTURBING ACTIVITY IS NOT BEING UNDERTAKEN WITHIN FOURTEEN (14) CALENDAR DAYS OF INSTALLATION) I II Ex. CB r CONTRACTOR TO FIELD � I _ I I TEMPORARILY OR PERMANENTLY SUSPENDING LAND DISTURBING ACTIVITY. TOP=351.99 19 A II I VERIFY I \ O SKIMMER DEVICE - I I III I I 12"RCP(E)=349.47 I SILT FENCE I (• I I • ESTABLISH PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION WITHIN FOURTEEN (14) CALENDAR I I I (TYP.) EX. CB TO BE CONVERTED ATTACHED TO RISER I 3 _ I II I PROPERTY LINE DAYS FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT AND/OR PRIOR TO FINAL INSPECTION. EX. JB I BARREL. RIM=352.17 III � �� I II I SILT FENCE OUTLET AT I \\ TO CITY OF RALEIGH , I I TO BE ABANDONED STANDARD CB �1 I n ALL LOW POINTS (TYP.) I 18"RCP(E)=349.34 I I / 9 II I Is RISER STRUCTURE' 77�I TEMPORARI� INLET III 12. MAINTAIN DEVICES AS FREQUENTLY AD NEEDED IN ACCORDANCE TO ENSURE LIMITED FAILURES AND TO PREVENT 12"RCP(W)=349.46 I EX. JB I �sLLT FENCE OUTL T I (TYP•) I PROTECTIO (1YP.) II ACCELERATED EROSION, OFF -SITE SEDIMENTATION, OR REPETITIVE NON-COMPLINACE ISSUES.SILT FENCE, INLET 12"RCP(NW)=359.58 / EX. CB TO BE CONVERTED PROTECTION AND OTHER SIMILAR FEATURES MUST BE CLEANED OUT BEFORE THEY ARE HALF FULL. CLOGGED I TO CITY OF RALEIGH (ASSUMED LOCATION) AL LOW POINTS .) - =-- I II II II STONE FILTERS MUST BE REFRESHED/REPLACED. SILT FENCE CAN NOT HAVE HOLES OR TEARS / I I STANDARD CB NIV IN(Oj4046.41 I \ T MPORARY INLET I _ �, - I STMP FENCE 13. SUBMIT DOCUMENTATION REQUIRED UNDER THE SITE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITY T - - - I %I INV OUT=346.41 � (TYP.) - J - / X PROTECTION TYP. I - - - - - / / _ _ - ! ) E E - - - (NCGO10000) TO STORMWATER INSPECTIONS THROUGHOUT THE PROJECT. n0 _ - N 87V8'S1=W 151.82 SS �y $$�� _ _ �T - - _ - - - - - - - - Iy �w --� I GREM AIN N 6+. 14. PRIOR TO COMMENCING PHASE I -STAGE 2, CALL THE RAPID RESPONSE TEAM AT 919-279-1308 FOR AN -_ �� .�� T I `EA I� `� h INSPECTION. IF APPROVED, COMMENCE WITH STAGE 2. \ \ F S Ts0 , SD - _��---�� --- _-� -�s�ds ise��s --- M Wv \ EX. CB s0 7 - -----� i ��� M M M M- \ TOP=35�1.�6 A A A X. 15" RCP SD -�- - - � �'� EX 5" RCP \ \ 12°RCP(E)=3 0.403 0' I \ '- - - - -' - _ _ _ m m f- Cn I i� X-1fr"-� P-- alv ti as--��---- / ---L � W � \ \ \ X 8" CIP W L �6 EX. GAS LIN\ TOP C343.17 � _ EX. CB / I _ ASSU D LOCATION) � PTO REMAIN \ 15"RCP(S)=338.31 � 6 9 6 - -� T/C=345.37 I m 1 rrrr� I Gl G7 = .. W / EX. FIRE ® ' cn m m m -W 15"RCP(E)=339.17 iR EX. WER POLE�A�JD m ci m W w HYDRANT �/ m EX. CB W W_ _ t5'RCP(W)=339.07 �'°` OVER :AD POWER TO BE '- I/ - _-� / EX. JB T/C=343.13 ci a W '" / RELOCATED AS NEEDED. f PORARY INLET �_ � (ASSUMED LOCATION) 15"RCP(N)=337.37 U EX. JB / / CO ACTOR TO COORDINATE `� �' p ECTION (TYP.) LIMITS OF � _ INV IN43.5§- 15"RCP(S)=337.27 - = RIM=343.07 ��` / W�APPROPRIATE UTILITY pI ER SERVICE TO BE DISCONNECTED INV IN(N)=338.7 � 15" RCP(NE)=336216 E--� / COMPANY �j I ' / / THE MANHOLE PER ;CITY OF RALEIGH / I (TYP ' / EX. SMH 15"RCP(W)=33 .79 EX. 3 x u� 15" RCP(E)=336.16 TANDARDS. IN LIEU OE SAWCUTTING RIM 345.38 15"RCP(E)-338.79 RIM=342.90 w w -15" RCP(W)=336.16 _ DISTURBED AREA = 2.00 AC. Y� DISCONNECT ACROSS OApTHE SERVICEATTHETIMAIN, / 6ON,"( )=338.18 / 7 ; 15 RCP(N) _336.93 12" PVC(NW)=339.21 - Vu �Qu oiu �� AND FILL ENTIR ABANDONED S RVICE WITH / 8"VCP(E)=338.23 / 15"RCP(W)=336.93 I 18" RCP(S)=336.06 - - - - - - �o / / / _ - _ - - / FLOAWABLE FI PER_RALEIGlf,STNDARDS. / - / EX. 8" SS 15"RCP(E)=336.9 EX. 8" SS n0 -Fo - ^� - - _ -3 - - - - _N1 ALL CONSTRUCTION SHALL BE IN dF EX. SSMH o \ �- ®� _ - cs - _ cisS - - - ACCORDANCE WITH THE CURRENT CITY RIM=352.57 �\ _ - - - _ _ _� _ - - - - - 0 - _ _ _ I -�L OF RALEIGH ENGINEERING DESIGN AND 8"VCP(N)=344.38 _ 8"VCP(S)=344.26 Ir EXISTING - - -/ - _ - - - _ 7__ •-_ CONSTRUCTION STANDARDS SS SSI�I I II I I® DEMO AND REMOVE -� ------ ss �/ III I I R GAN S T . rL ►' - - - - � - �M SS Ss HYDRANT I I I II I M (VARIABLE WIDTH PUBLIC R yy DRIVEWAY, , PAVEMENT, -r _ _ _ _ ---- - -�- _ PLANNED PARENTHOOD OF GREATER III o I" VA / ) I / WALLS, SIDEWALKS, CURB I I 1 -Y _ _ - NOTICE TO CONTRACTOR RALEIGH INC I ' I II I � I .. -��° - ,� EXISTING GAS LINES ARE PRESENT ON 100 S BOYLAN AVE I I III I I II I I N/F , �� POLES UTTER, AND LIGHT I I I E E E PIN 1703-38-9868 CROCKER FAMILY EROSION CONTROL MAINTENANCE PLAN SITE. CONTRACTOR IS TO VERIFY DB 4798, PG 489 ( ~ II u I I 1 1 '' Ih I I PROPERTIES LLC I \ I II 0.47 AC. 615 W MORGAN ST 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED BY THE SITE CONTRACTOR FOR LOCATIONS PRIOR TO ANY EXCAVATION ZONING: OX-7-UL EX. VARIABLE WIDTH PIN 1703-48-1885 PUBLIC R/W DB 16759, PG 165 STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE CONSTRUCTION ACTIVITY TO MAINTAIN 0.63 AC. EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. THE SAFEST ENVIRONMENT POSSIBLE. ZONING: DX-7-UL 2. SEDIMENT FENCES SHALL BE INSPECTED AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. REPAIRS SHALL BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED AS NEEDED TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAINFALL EVENT, AND TO REDUCE PRESSURE ON THE FENCE. FENCING MATERIALS AND SEDIMENT DEPOSITS SHALL BE REMOVED, AND THE AREA BROUGHT TO GRADE FOLLOWING STABILIZATION OF UPGRADIENT DISTURBED AREAS. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 a- HERITAGE Y PROPERTIES, INC W r(� V z� U W off W M 0 I(A ( N M V = z 00 z J �:O< VQcc- O °COS = J 0 W O m z z 0 (D LU U M < N) N z O U ,/lulu J`� CAS :Q �.�. (:jj49 ` = iG I NE � , S. • SLP.�•`��,, �itllllllll`` REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-EC1 CHECKED BY CHT DRAWN BY CHT SCALE 1"=20' DATE 12. 1S. 2018 SHEET EROSION CONTROL PLAN STAGE I EC�l PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION NF ■ , / I I HILLSBOROUGH 630 LLC N/F N/F ' 1 L 11 / 630 HILLSBOROUGH STREET AYCOCK, MAHLON L WILDER, RYON W I HSA LIMITED PARTNERSHIP PIN 1703-49-1348 618 HILLSBOROUGH ST 610 HILLSBOROUGH ST N/F DB 16997, PG 1152 EXISTING PIN 1703-49-2349 I PIN 1703-49-3325 THE BAR STOOL INC l EX. FIRE 0.30 AC. DB 2790, PG 13 DB 4908, PG 342 600 HILLSBOROUGH ST HYDRANT- - ZONING: NX-7-UL HILL S ®R ®UGH S T • 0.38 AC. 0.34 AC. PIN 1703-49-4345 _ _ _ - - - - ! 1 ZONING: NX-7-UL ZONING: NX-7-UL DB 13828, PG 1200 ��` I (VARIABLE WIDTH PUBLIC R/W) I VARIABLE WIDTH PUBLIC 0.18 AC. �c \ - - - - -_ �� - - - _ _ _ _ - R/W ZONING: DX-7-SH �G�c J --y- ss ss -wLwG w w \ �W\- w- w / �- �-• G _ X. G ASLIRE- s ss w- w- w- c_c- ss-ss T ss ; w- w wG G SMS c c- ---- �- -----_---- ss ss \ EX. 8" CIP W/L (ASSUMED LOCATION) _r_ - ss ss LIMITS OF w wv \ ---- 3 ; ss ss EX. 8" SS EX. 8" W L (TYP.) ss - w w \ 1 - I EX. SSMH \ -9 - SS SS SS SS SS 1 / RIM=355.14 ��- '�-� -9 �� ss ss SS / 3 8"VCP(N)=348.98 ` / �- ��- -�� 7-ss - 1 8"VCP(E)=348.61 - - - - �� / 8"VCP(W)=348.73 - 9 \ LIMITS OF DISTURBANCE 54- _ - -- -- Fo LD- "_� LD - LD =moo e c / \ sF - $ s LD to Lo SILT FENCE 9 / R - SF - sF - SF = s� `D 1D I o w (TYP. - sF SF SF SillSF _ SF_ LD I.c Ln 36 3n \ SILT FENCE OUTLET AT SILT FENCE OUTLET AT ALL LOW POINTS (TYP.) , - - - _ _ - ALL LOW POINTS (TYP.) I - I I � - 1 6 SILT FENCE r I v (TYP.) /\ I / 1 TEMP. GRAVEL CONSTRUCTION I ; ENTRANCE/EXIT ,I l i \ J ---���4 LIMrr- - -- - _ 1 �I I III DI E I I s t� \v I I I 13 � 11 I 1 II � EX. WATER METER 1- _ / � I I 1 LOT 3 1 ,I N/F / �' H I 1 1 - - -� j \ I / I I 40 611 SF AC FMW AT 7Q1, HILLSBOROUGH LLC ►--� Q II I 1I 701 H L,LSBOROUGH ST ( �-.� �� I 3E I \� ZONING: DX-12-UG PIN 11103-49-0106 e 1 DB i 37, PG 2509 - 1 L -I - r I ( / /� /� & DX-12-UL BM 87, PG 1251 .43 AC. � � ' I I I I I ZO NX-7-UL � a � I � __ _ �` / L IMPROVEMENTS LOCATED ON I _� GLENWOOD ONE OFFICE, LLC /I BE \� I �3 \ Ivl HATCHED AREA TO BE ZED PRIOR 0 I P \ \ - - - - - -- - - -- -- J �/ IF I APPROPRIATE TEO PLANS REVISED ISEDER N =$ 1 PROPOSED F U E PROJECT SITE Ix I I ICA 1 R N E ONLY III I I \I 1 REMOVAL OF SP-1. I / 1 0 i I I 1r 6 CASE #SR-45-16 1 ri (ASSUMED 0� IMPERVIOUS) z 1 TRANSA TI 70573539 L / LOT 1 - - 1 ----� I /CASE # S I I s 1 // / 36,938 SF - �$ 8 I / < I / t0.848 AC / � � � I I / f � �„ \ I ZONING: DX-12-UG / I / I-m\ a / & DX-12-UL 358 LOT 2 3 - 3,957 SF I I LIMITS OF U LCJ TEMP. GRAVEL CONSTRUCTION t0.091 AC I I DISTURBANCE ` ENTRANCE/EXIT I / ZONING: DX-12-UG I� 3 � �x-� UL I \ 1 1 r- E-i _j I/ 11 4 349 jt PREVIOUSLY APPROVED PROJEC d - s / I / SEE CITY OF RALEIGH \ \ X. SSMH \ - I 3 CASE #SR-45-16 wI E \8"VCP(S) 1346.91 II I - - - 1amm I I /� G 348 / S f I I9 / TEMPORARY CHECK L DAM (TYP.) �� Z 348 TEMPORARY DITCH TD-2 LINED WITH �� NAG ERONET C125 OR EQUIVALENT. /� 1 / \ ` N �� I j o� TEMPORARY CHECK / DAM TYP. �[ J ftft still l 7 1 _ �I I 351 (TYP.) TEMPORARY CHECK DAM II I - - N _ 1 17 s* I � I I �I II V' 1 TEMPORARY DITCH TD�-1 LINED WTH- TEMPORARY DIVERSION E- OSDITCD) TEMPORARY CHECK NAG ERONET C125 OR EQUIVALENT. HBERMTYPL II II I !- N/F -►'�',-�',-�►� I I �►�DAM ► �� L III I II 1700 WEST MORGAN LLC I I I I II 1 � \ ��34__ PIN 1703-49-0004 ~� �l 1 DB 11755, PG 933 I �I \W w I COIR BAFFLES (TYP.)�' III I i II I 0.15 AC. VARIABLE WIDTH PUBLIC I ZONING: NX-7-UL R/W II � HATCHED AREA TO BE (SEE BASIN DETAIL FOR I 11 N STABILIZED PRIOR TO INSTALLATION) . EX. CB �I (I I SILT FENCE REMOVAL OF SB-1. TOP=351.99 II�1131EI 9 I (TYP.) fff \ ATTACHED DEVICE RE R, I -�� 1 I I 12"RCP(E)=349.47 t� C ED 0 SE 1 I I I SILT FENCE OUTLET AT \ BARREL. SEE SUMMARY 1 II1 ST-1 EX. JB TABLE SHEET C-X III I (SEE SUMMARY TABLE) I RIM=352.17 L� � i�/ I I ALL LOW POINTS (TYP.) 18"RCP(E)=349.34 I I / 9s RISER STRUCTURI 11 0 11I 11 12"RCP(W)=349.46 / �(TYP-) 345 I III 11 12"RCP(NW)=359.58 I _ _ 4 CONVERT EX. CB - - 41CO 1- - T - - - - I % 9 TO COR STD CB a - 4 - �� - J� / - - - SILT FENCE I - - �' _ • � _ no - no - - -� /� I JB-118 a "�) a / SILT FENCE OUTLET AT _� ��`� - _ _ _ -T- 1- 1 \ G r ALL LOW POINM-PYP.) -ij �, 6 - - IW - - - - �o I EX. CB-117 TEMPORARY INLET _ I� U 01 1 T- \ \ EX. Cv8 9 sG \- gn �^ PROTECTION (TYP.) " M - wv EX. J EX. 15�' RCP \s� - S -� M M M M C \ TOP CP(E) 6 \ - - ` EX. 15" CI \ 12"RCP(E)=3.40 3 0' (ASSU ED LOCATION \ V CON -EX -CCU 15��� G Wv 4� \ \ TO COR STD CB °� m RCP, 6 - - X-15= RGP- - _ _ 'as lNV IN - 46.41 _ \ V A \ EX. 8" CIP L \ \ �\ EX. CB 6 �- - _X �'_RCB os EX. CB - I I I INV 0 = .41 w I\ w- ASSUMED LOCA N \ _ \ 6 T/C=343.13 9 T/C=345.37 1 `�--- a1 cn �� m -W-t j _ 15"RCP E=339.17 / EX. FIRE / I �- / cn - 15 RC S)=3 �w w w " w- (5"RCP(W)=339.07 HYD�ANT ��--� -�-" / EX. JB cI N a /TEMPORARY INLET _ / _ ���I �� (ASSUMED LOCATION) . ;N�j R M 343.07 / I EX. JB PROTECTION (TYP.) LIMITS OF 4- - RIM=343.59 EX. JB �-� o ( )_ 1 / ' DISTURBANCE! / / / INV IN(N)=338.7 � 15" RCP NE =33 6 (TYP.) / EX. SMH 15"RCP(W)=338.79 RIM=342.90 u, 15' RCP(E)=336.16 ~� I - - - _ / f / I / / / RIM 345.38 15"RCP(E)-338.79 15 RCP(N)=336.93 W -15" RCP(W)=336.16 7 - �_ I / / / / 6"(=338.18 / 3 15 RCP(W)=336.93 12" PVC(NW)=339.21 �p - ou �� / / / 8"VCP(E)=338.23 / 15"RCP(E)=336.93 I 18" RCP(S)=336.06 ____ ___ 1----- -- L --- �- / EX. 8" SS - \ / -- - - -�-- - - '�- ss ss no - EX. 8" SS no rnl EX. SSMH - \ - '� \ - - ® _ 3 `� - CIS RIM=352.57 � �\ - ---�- -- %--�----\ I-- 8"VCP(N)=344.38 - 1 8"VCP(S)=344.26 1r EXISTING - - -, - _ - - - _ �__ - L 1 II I I W . MORGAN SS ss - - - / -� --- m----- , N F EX. FIRE I III I I I VARI R G1�� S T. - - -4� ® p- - - - _L _��, - ss_ ss _ PLANNED PARENTHOOD OF GREATER HYDRANT 111 I / III I (VARIABLE WIDTH PUBLIC R W / I r - - - - - --_-__ _- -�--- - RALEIGH INC I I I 11 I r I / )\/ I I �r 1 1 100 S BOYLAN AVE I I I I I/ II I I N/F / 11 �1 I I I I 1 1 N/F II I PIN 1703-38-9868 II I I CROCKER FAMILY j � 344 L I- - I RALEIGH HOTEL GROUP, LLC DB 4798, PG 489 i W II I I 1 1 5' Ih I PROPERTIES LLC I \ I II !� a I ins - - I I- - - - r 603 W MORGAN ST 0.47 AC. 615 W MORGAN ST PIN 1703-48-4920 ZONING: OX-7-UL VARIABLE WIDTH PUBLIC PIN 1703-48-1885 DB 16986, PG 2031 R/W DB 16759, PG 165 0.23 AC. 0.63 AC. ZONING: DX-7-UL ZONING: DX-7-UL EROSION CONTROL LEGEND IIII�IIII� SILT FENCE OUTLET INLET PROTECTION INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN FILTER BERM CHECK DAM -SF -SF -SF- SILT FENCE - TP - TP - TP - TREE PROTECTION FENCE LD LD LIMITS OF DISTURBANCE WOODED AREA DIVERSION DITCH o RO °� 0f.0" �o° CONSTRUCTION ENTRANCE/EXIT uo °° O° CONSTRUCTION SEQUENCE - STAGE 2 1. PENDING STAGE 1 IS COMPLETE AND ALL APPROVAL AND INSPECTIONS HAVE TAKEN PLACE. 2. BEGIN INSTALLING PROPOSED BUILDING FOUNDATIONS AND BUILDING RETAINING WALLS. 3. BEGIN GENERAL SITE GRADING SHALL COMMENCE IN ORDER TO ASSURE POSITIVE DRAINAGE. 4. ALL DISTURBED AREAS MUST BE STABILIZED WITHIN 14 DAYS OF INACTIVITY. 5. INSTALL ANY CURB AND CONCRETE THAT IS CONSTRUCTIVELY FEASIBLE AT THIS TIME OF CONSTRUCTION. ONCE NEW CURB LINES ARE ESTABLISHED MOVE SILT FENCE TO THE BACK OF CURB OR TO AREAS THAT DO NOT IMPEDE FUTURE HARDSCAPE CONSTRUCTION. 6. INLET PROTECTION SHOULD BE INSPECTED AND MAINTAINED AFTER EVERY RAINFALL EVENT. NO OPEN TRENCHES SHALL BE LEFT AT THE END OF THE WORK DAY. CONTRACTOR SHALL INSPECT AND REPAIR ALL EROSION CONTROL DEVICES UNTIL THE AREAS HAVE BEEN STABILIZED AND APPROVED. THE CITY OF RALEIGH STORMWATER CONTROL DEPARTMENT RESERVES THE RIGHT TO ISSUE A NOTICE OF VIOLATION IF EROSION CONTROL DEVICES ARE NOT PERFORMING CORRECTLY. FOR THIS REASON THE CONTRACTOR MAY BE REQUIRED TO INSTALL ADDITIONAL MEASURES AS REQUIRED IN THE FIELD TO PERFORM THE CONTROL OF SEDIMENT LADEN RUNOFF. 7. GRADE OUT OFFICE BUILDING PAD FOR THE PROPOSED OFFICE BUILDING. STABILIZE GRADED BUILDING PAD AREA WITH SUITABLE SUBGRADE MATERIALS. 8. ONCE OFFICE BUILDING AREA HAS BEEN STABILIZED CALL THE RAPID RESPONSE TEAM AT (919)-857-4412 TO SCHEDULE A STORMWATER SITE INSPECTION. ONCE APPROVED BY CITY OF RALEIGH STAFF, REMOVE THE TEMPORARY SEDIMENT BASIN SB-1 AND PROCEED WITH IMPROVEMENTS PROPOSED IN THAT AREA. 9. GROUND COVER SHALL BE PROVIDED AS FOLLOWS: • FOR ALL AREAS OF MODERATE AND/OR STEEP SLOPES, PROVIDE TEMPORARY GROUND COVER IF THE SLOPE HAS NOT BEEN DISTURBED FOR A PERIOD OF FOURTEEN (14) DAYS. • PROVIDE GROUND COVER SUFFICIENT TO RESTRAIN EROSION ON ANY PORTION OF THE SITE UPON WHICH FURTHER LAND -DISTURBING ACTIVITY IS NOT BEING UNDERTAKEN WITHIN FOURTEEN (14) CALENDAR DAYS OF TEMPORARILY OR PERMANENTLY SUSPENDING LAND DISTURBING ACTIVITY. • ESTABLISH PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION WITHIN FOURTEEN (14) CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT AND/OR PRIOR TO FINAL INSPECTION. 9. SUBMIT DOCUMENTATION REQUIRED UNDER THE SITE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITY (NCGO10000) TO STORMWATER INSPECTIONS, 919-279-1308. 10. WHEN STAGE 2 IS COMPLETE AND PRIOR TO COMMENCING TO STAGE 3 CALL 919-279-1308 FOR AN INSPECTION. 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED BY THE SITE CONTRACTOR FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. 2. SEDIMENT FENCES SHALL BE INSPECTED AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. REPAIRS SHALL BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED AS NEEDED TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAINFALL EVENT, AND TO REDUCE PRESSURE ON THE FENCE. FENCING MATERIALS AND SEDIMENT DEPOSITS SHALL BE REMOVED, AND THE AREA BROUGHT TO GRADE FOLLOWING STABILIZATION OF UPGRADIENT DISTURBED AREAS. DISTURBED AREA = 2.00 AC. EXISTING GAS LINES ARE PRESENT ON SITE. CONTRACTOR IS TO VERIFY LOCATIONS PRIOR TO ANY EXCAVATION CONSTRUCTION ACTIVITY TO MAINTAIN THE SAFEST ENVIRONMENT POSSIBLE. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE a Y PROPERTIES, INC LU V z� U LU LU M N M V = z 00 z J �:O< VQcc- O °COS = J 0 CO O m z z 0 (D LU U ) M < = N issississis z O U CAS ts j. 7 1 �e.'� q .......... I .... � 1,,, n,, ,,%1 REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-EC2 CHECKED BY CHT DRAWN BY CHT SCALE 1"=20' DATE 12. 1S. 2018 SHEET EROSION CONTROL PLAN STAGE 2 ECIIIIIIIIIIIIIIIIIIIIIIIII L II HILLSBOROUGH 630 LLC I AYCOCK, MAHLON LFWILDER, RYON W I N/F 630 HILLSBOROUGH STREET N/F 7 `/ i PIN 1703-49-1348 618 HILLSBOROUGH ST HSA LIMITED PARTNERSHIP THE BAR STOOL INC DB 16997, PG 1152 EXISTING PIN 1703-49-2349 I i 600 HILLSBOROUGH ST T T L� � 7 610 HILLSBOROUGH ST I �+�"���®�®lJ �H S�• DB 0.38 AC. 13 PIN 1703-49-3325 PIN 1703-49-4345 0.30 AC. ZONING: NX-7-UL DB 4908, PG 342 0.34 AC. DB 13828, PG 1200 ( ZONING: NX-7-UL ZONING: NX-7-UL i 0.18 AC. - - _ I VARIABLE WIDTH PUBLIC R/W) I ZONING: DX-7-SH -wawa- c- -�-emswn�w cJG=GL c Q-c c =--- -w ww c G�c c - �_--`- ss EX. RCP 8" SS w w- !w- w / w- w- r_ cio�c- c cSS - - • _ ss EX. RCP 8" SS �� 9w w �� c c c ---- �\ ss --�_ SS SS SS w� Ml \ w- w- w- w w EX. 8W CIP W/W-(ASSUMED LOCAT ON) o LD � � I\ -�- ss w wvImam F " w --- ss ss EX. 8" RCP SS w � \ 9 s SS ss o f - w� M / f \ � -in now\ \ 9 f� ss SS SS E. 8" RCP IS wow-w-w- 7 SILT FENCE OUTLET AT 9 / I ALL LOW POINTS TYP. - - TEMP. GRAVEL CONSTRUCTION ENTRANCE/EXIT PRECAST CONCRETE _ - _ 5 _ / / / 9 SILT FENCEWALLS TYP, LIMITS OF (DESIGN OTHERS) - \ LD LD I J (n,P) DISTURBANCE - - 9 (TYP.) a�.� 7�5 / ✓ LD LD LID �S'F � LD LD LD I � 1 �9 s _ _ �� / T a = _ _ - 3n T LD LD I 6 `I F 35� _ _-�- all- n PROPOSED © �__ _ R/W 35 � \ � / I I I f ��-- _---- 2 I� I \ --- I �3S + I I I 9 \ AREA DRAIN II 304 (TYP.) 1 IT 20' MAX. I / I \ II I I/ oF• � ��,FFE= BUILD -TO � I � 1353.97 I n r I EROSION CONTROL LEGEND SILT FENCE OUTLET ila�ai�cz•�rx�rl:•�. INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN FILTER BERM yaX•l.��l_l�l SILT FENCE TREE PROTECTION FENCE LIMITS OF DISTURBANCE WOODED AREA DIVERSION U, CONSTRUCTION ENTRANCE/EXIT DISTURBANCEI ! ; ' / �v I I _ I CONSTRUCTION SEQUENCE - STAGE 3 1 I I FIRE RETAIL _ - ` (NP') \ I ( 30'x30' CORNER = I ; O PUMP FFE 352.97 I 3 I 1. PENDING STAGE 2 IS COMPLETE AND ALL APPROVAL AND INSPECTIONS HAVE TAKEN PLACE. 1 • ! ®, II II Z \ I t I STEP ACCESSORY LOT BUILD -TO / I I ACCESSORY STRUCTURE NORTH BUILDING 2. INSTALL STORM DRAINAGE SYSTEM FROM EX. CB-1 17 TO AND INCLUDING THE SWMF (SEE SW SHEETS RETAIL h STORMWATER I FFE=352.05 FOR DETAIL) AND FROM THE SWMF TO JB-200. INSTALL STORM DRAINAGE STARTING DOWNSTREAM AND o I FFE=353.97 - _ CONTROL I AREA DRAIN 6' WORKING UPSTREAM OF THE DRAINAGE SYSTEM. BE SURE TO USE PIPE INLET PROTECTION ON ALL FMW AT 701 HILLF�90ROUGH LLC �' II o I I 20' MAX. MEASURE A I i / (TYP) F , EXPOSED PIPES NOT CONNECTED TO A STRUCTURE AT THE END OF EACH WORKDAY. ( Q 701 HILLSBOf O GH ST rrr I I BUILD -TO » » I I N/F PIN 1703-44 0106 I �' I I I STAIRS (SEE SW SHEET) I 3501 GLENWOOD ONE OFFICE, LLC 3. CONTRACTOR IS TO INSTALL CONCRETE, AND ANY REMAINING CURB AND GUTTER THAT IS DB 16937,�3 2509 Z+ 1 GLENWOOD AVE CONSTRUCTIVELY FEASIBLE AT THIS TIME OF CONSTRUCTION. E i x v / I' r I , II 0.43 ~ � J� 9 I I I (NP•) I I _ i PIN 1703-49-4101 BM 1987, IR 1251 I \ I \ I I I 3 I �I DB 16926, 0.70 AC. 570 a�' I4. ADJUST TEMPORARY CONSTRUCTION ENTRANCES AS NEEDED TO ALLOW ACCESS TO SITE. ZONING: I�X7 UL- I� ZONING: DX-12-UG, DX-12-UL STEPS WITH 5. ALL DISTURBED AREAS MUST BE STABILIZED WITHIN 14 DAYS OF INACTIVITY. I 1 I- W III I \ I I _ I I HANDRAILS / I 3 6. REMOVE TEMPORARY CONSTRUCTION ENTRANCES ONCE APPROVED BY THE CITY OF RALEIGH EROSION r W I tO \ (TYP.) I I �`� '� CONTROL INSPECTOR. I {]� W LAINAGE LOBBYPRIVATE I I -�� _' 7. INLET PROTECTION SHOULD BE INSPECTED AND MAINTAINED AFTER EVERY RAINFALL EVENT. NO OPEN /FFE=353.30 EASEMENT = TRENCHES SHALL BE LEFT AT THE END OF THE WORK DAY. CONTRACTOR SHALL INSPECT AND REPAIR �a,IMPROVEMENTS LOCATED oN N ALL EROSION CONTROL DEVICES UNTIL THE AREAS HAVE BEEN STABILIZED AND APPROVED. THE CITY O_ GLENWOOD ONE OFFICE, LLC RALEIGH STORMWATER CONTROL DEPARTMENT RESERVES THE RIGHT TO ISSUE A NOTICE OF VIOLATION I I PROPERTY To BE REVISED ON b AREA DRAT �� � � � � � I / f �, I \ I \ , (Typ,) - APPROPRIATE PLANS UNDER � EROSION CONTROL DEVICES ARE NOT PERFORMING CORRECTLY. FOR THIS REASON THE CONTRACTOR I CASE #SR-45-16 MAY BE REQUIRED TO INSTALL ADDITIONAL MEASURES AS REQUIRED IN THE FIELD TO PERFORM THE --- IELEVATORS CONTROL OF SEDIMENT LADEN RUNOFF. e I I � 8. INSTALL THE REMAINING CURB, BASE ASPHALT LIFT AND CONCRETE ON SITE. 4 1 \ 1 STEPS WITH I ILT ENCE NOTE: FINAL LIFT OF ASPHALT SHALL BE PLACED ONLY AFTER SITE IS COMPLETELY STABILIZED AND 4 \ HANDR�ILS I / I (TYP.) OFFICE ROOF SYS i \ I , / / / � � I tI � APPROVED BY THE EROSION CONTROL INSPECTOR. CAMP I - . I AC TIE IN POINT i I (PROPOSED �UTl7RE--PROJE� � \ -« � / / TOR , � I � � � �_, \ REFERENCE ONLY \ 1 � I I � I I I I � � � II � i' 9. ONCE GRADING IS COMPLETE AND THE SITE IS STABILIZED, CALL THE EROSION CONTROL INSPECTIONS I/ I / PREVAUSLY APPROVED PROJECT SEE ASSUMED 100� IMPERVIOUS I II / LOADING JI PRIVATE / I - CITY OF RALEIGH REGIONAL COORDINATOR AT (919) -279-1308 TO REQUEST AN INSPECTION AND APPROVAL FOR ) I I I I I / \ DRAINAGE / / I CASE #SR-45-1 PHASE -I AND TO REMOVE TEMPORARY MEASURES. DO NOT REMOVE TEMPORARY MEASURES PRIOR TO TRANSACTION 573539 I (� -REFUSE - � \ EASEMEN So ; ' STORMWATER INSPECTOR APPROVAL. CASE SR-1B200 00-18 I I II I I I ` I' -FFE=352.8o- - / II PRIVATE DRAINAGE 10. IF SITE IS APPROVED, SEED OUT AND/OR PAVE WITH THE FINAL LIFT ANY PROPOSED PAVED AREAS. EASEMENT We 11. REMOVE SILT FENCING, INLET PROTECTION, ETC. \ \\(jilrl II I RETAIL ��`�,\1 /-/ 12. ALL GRATES AND LIDS SHOULD BE INSTALLED AT THIS TIME. \ \ ^ I / 11 - - - - FFE=349.80 I Oil II I 34 3 13. ONCE GRADING IS COMPLETE, TEMPORARY MEASURES ARE REMOVED AND THE SITE IS STABILIZED CALL GENE JB-117B - - / _ LIMITS OF `� / �� THE RAPID RESPONSE NUMBER (919)-857-4412 TO SCHEDULE A STORMWATER FINAL INSPECTION. TRAN FORMER I DISTURBANCE .I /� FULL STABILIZATION ON THE ENTIRE SITE IS REQUIRED IN ORDER TO OBTAIN A CO. \ \ \ I I I I I =352.80 RATOR O \ \ 3g 3 (TYP.) FE-352.80 ,•..„,,, „�„ - / / �� / /rl / I NOTE• LAND DISTURBANCE PERMIT SHALL EXPIRE TWO 2 YEARS FROM DATE OF ISSUANCE RIM=353�1 \ \ 8"VCP(S) �46.01 I I o OSED f 17 I I I I• N N/F I �I t z 2 II 700 WEST MORGAN LLC o aD I PIN 1703-49-0004 X� 19 \ DB 11755, PG 933 , I �I \0 0.15 AC. II Q I IIn ZONING: NX-7-UL �II EX. CB �I 1 \ III za I TOP 351.99 12"RCP(E)=349.47 /I -T----�--_ I w % 9 ^n -� \ / \ TOP �7 �352.9�6 \ 12"RCP(E)=3 0.40 3 \ �w 'WV TEMPORARY INLET PROTECTION (TYP. w w�I\ ° EJSSMH / / RII�"352.57 / Sr'VCP(N)=344.38 \ OU --�---_ __-- no / -----1----�--- ^��-no 170 \` 1)0 A\ �/70 I/ NF III�Iq � a I PLANNED PARENTHOOD OF GREATER I~ III � � I 9i3I RALEIGH INC I l u 100 S BOYLAN AVE I I Np I PIN 1703-38-9868 n w I I DB 4798, PG 489 I i r B I 11 1 5' Ih I 0.47 AC. ZONING: OX-7-UL m ai1_ J m 01 m� ,,,- / 1 �cmnj RETAININc� WALL �-_ /IGNyBY OTHERS) EX. CB 17 / EX. JB/ / �y T/C=3 3.80 ! EX. JB - EX. JB / (ASSUMED LOCATION) I INV O�T(S)=339.00 (ASSUM RIM=352 17 RIM= 50 40 LIMITS OFF J TEMPORARY DITCH TD-2 LINED WITH ERONET C125 OR EQUIVALENT. II ACCESSORYSTRUCTUREII SOUTH BUILDING I I FFE=346.79 EX. PRIVATE DRAINAGE EASEMENT EX. SSMH RIM=343.38 8"DIP(E)-334 27 EROSION CONTROL MAINTENANCE PLAN I1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED BY THE SITE CONTRACTOR FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS I THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. I 2. SEDIMENT FENCES SHALL BE INSPECTED AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. REPAIRS SHALL BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED AS NEEDED TO I PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAINFALL EVENT, AND TO REDUCE PRESSURE ON THE FENCE. FENCING MATERIALS AND SEDIMENT DEPOSITS SHALL BE REMOVED, AND THE AREA BROUGHT TO GRADE FOLLOWING STABILIZATION OF UPGRADIENT DISTURBED AREAS. SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN / ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND I�111 11 8 DIP(S)=334.27 r 11 + vv u � -_� EXM 15"' RCr ".dK CONSTRUCTION STANDARDS / *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. i -X 1 ter- _� as ---- sD�3- _ EX. /CB - / � T/C=345.37 -w 15/"RCP(E)=339.17 Na W-W- w� �5"RCP(W)w 339.07 / w w�w� o EX. JB / I RIM=343.07 I / RIM=34 .tea 15"RCP S-337.27 ' _ 15" RCP(NE)=3366 0 18"RCP( )=349.34 INV IN(N)=346.41 DISTURBANCE / EX. SSMH INV I (N)=338.79 EX.( JB io ^� 15' RCP(E)=336.'16 12"RCP W)=349.46 INV OUT=346.41 TYP.) / x x 15" RCP W =336.16 /( ( / RItv1�345.38 1 �P(W)=338.79 I RIM=342.90 W w ( ) 12"RCf(NW)=359.58 / 8" CP(E)=338.23 /15" RCP(E)=338.79 3 15"RCP(N)=336.93 I 12" PVC(NW)=339.21 / / / 15"RCP(W)=336.93 18" RCP(S)=336.06 EX. 8" DIP SS 15"RCP(E)=336.93 $ EX. SSMH _SS ss ss EX. 8" DIP SS RIM=342.98 - •"� ` \- - - - - 8"DIP(N)=333.68 \ \ - (-nl 8"DIP (W)=3 3.48 I EXISTING _ - ^I I _ I I W. S EX. SSMH / ■ � � _� - -�-- -S � SS - - �/ r/ W gD � MORGAN +J RIM Z-43:25- 3&4/ I�- _ _ _ _ �- SSA SS SS MI MI �I I (VARIABLE WIDTH PUBLIC I 8'DIP(E)=333.06 ® I Y- - �--L= - _ SS/ r I BLIC R/W) I \ 8"DIP(W)=334.74 I I I JP N/F f 10"DIP(16"ENCASEMENT) I �r 1 1 1 1 1 N/F ~ __ I I CROCKER FAMILY PROPERTIES, LLC I + / (S)=333.05 I 1 01 344 L I_ _ _ I -� 11 615 W MORGAN ST I II 1,1,E I , �, - _ L� _ _ _ I RALEIGH W ORGAN GROUP, LLC PIN 1703-48-1885 PIN 1703-48-4920 DB 16759, PG 165 DB 16986, PG 2031 0.63 AC. 0.23 AC. ZONING: DX-7-UL ZONING: DX-7-UL DISTURBED AREA = 2.00 AC. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 r HERITAGE PROPERTIES, INC LU (� V z U W CC LLJ cn O rZ I r4 M �'7=z 00 zc�J �OU D = V Q== O °COP J 0 CO 0 m z z 0 (D U LU Q v I z O U �. N CAS °F'S 7 GIs. ' : a' S. 1111111100. REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-EC3 CHECKED BY CHT DRAWN BY CHT SCALE 1"=20' DATE 12. 15. 2018 SHEET EROSION CONTROL PLAN STAGE 3 EC-3 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION L II fil• I�� HILLSBOROUGH 630 LLC AYCOCK, MAHLON LFWILDER, RYON W I 7 630 HILLSBOROUGH STREET I N/F , N/F PIN 1703-49-1348 618 HILLSBOROUGH ST HSA LIMITED PARTNERSHIP THE BAR STOOL INC DB 16997, PG 1152 EXISTING PIN 1703-49-2349 I 600 HILLSBOROUGH ST 610 HILLSBOROUGH ST I HILLSBOROUGH STD DB 0.38 AC. 13 PIN 1703-49-3325 PIN 1703-49 4345 0.30 AC. DB 4908, PG 342 ' DB 13828, PG 1200 , _ ZONING: NX-7-UL 0.34 AC. 0.18 AC. ZONING: NX-7-UL ZONING: NX-7-UL /�Oc �/ � � � ❑O - - - � _ _ _ ��- _ (VARIABLE WIDTH PUBLIC I ZONING. DX-7-SH ----- \ ----- ------ W. f R W -WG� w= G WG�G G G 0 G G G -� W W G G- ss ss T EX. FRCP 8" SS W w ! w- w�- W- �- GLD � G c G G G �- - - - - _ _ _ 1 - ` , - -- Fo _ 39 \_ss ss 3 W g w w W w G c -� _ FS ss- G- G ---- _ �- I �- ss w w w- W- W EX. 8W CIP W/L (ASSUMEDLOCATION) - ss ss _ ss -r- \ W 1p - \W� W WNM WVjumm ss"� ss ss EX. 8" RCP SS W ; g \ ` ss ss ss �_ w w w w ' ` --W_ W- Wv _ ss _ 6 � i SS W� / / t / \ I \ \ \ 9 f--- ss �s ss EX. 8" RCP IS I 3 ` 3 0,, I ■ � �� I � Ssss ` SILT FENCE OUTLET AT - - g \ I ALL LOW POINTS (TYP.) / I / / I TEMP. GRAVEL CONSTRUCTION / ENTRANCE/EXIT T - PRECAST CONCRETE - _ _ WALLS TYP. - �- LD g SILT FENCE LIMITS OF DESIGN BY OTHERS 6 _- = - a, LD -- TYP.) DISTURBANCE ( ) F0- i �' LD ( (TYP.) E SF �D %% SILT FENCE OUTLET AT -_ SF �SFI _� LALL LOW POINTS (TYP.) S SF W LD in --- NSF-- 06 ��llan SF / I W 3 / Li 0. - 1 N/F I �I FMW AT 701 HILLSR ROUGH LLC 701 HILLSBORQ GH ST PIN 1703-41 i 0106 DB 16937, P 2509 Z� BM 1987, P 1251 0.43 A ZONING: iXI� 7rUL r \ I \00 II SILT FENCE OUTLET AT ALLY POINTS (TYP.) 7 I (PROPOSED _FUTURff-PROJ9SITE, \� REFERENCE ONLY (ASSUMED 100% IMPERVIOUS) TRANSACTION# 573539 CASE # SR-100-18 n N/F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7-UL RIM-3TP1 3 8"VCP(S)=346.01 EX. CB TOP=351.99 12"RCP(E)=349.47 \ \ EX. C\B \ TOP=352.96 \ 12"RCP(E)-3550.40 \ ■ rt EX.�SSMH RIMS�-352.57 / �''VCP(N)=344.38 8"VCP(S)=344.26 N/F PLANNED PARENTHOOD OF GREATER RALEIGH INC 100 S BOYLAN AVE PIN 1703-38-9868 DB 4798, PG 489 0.47 AC. ZONING: OX-7-UL g \ cl I I INV OUT(S)=346.68 �I :D I cl I I CONVERT EX. CB TO COR STD CB SILT FENCE OUTLET AT ALL LOW POINTS (TYP.) LCID w� It I -- I SILT FENCE \ (TYP.) S S T SD SD S -7- SD SD EX. 5" RCP- \ TEMPORARY INLET \ \ & \ PROTECTION (TYP.) \ w� 7 Iw m w m w W EX. w SS \ / RETAINING WALL / JB �- (DESIGN YY OTHERS)_ s OF EX. JB (ASSUMED LOCATION) DISTURBANCE' I I / RIM=352.17 RIM- 50.40 I (TYP.) / 18"RCP(E)=349.34 INV IN(N)=346.41 I / 12"RCP(W)=349.46 INV OUT=346.41 I / 12"RCP(NW)=359.58 no nf no no �- F0F0 0%) T - (- `` 170 - IIV ,J�-JJJ.VV ��JJ I V �V..�IIVIV� RIM=343,.59 - EX. SSMH INV IN(N)=338.79 RIM�345.38 15; RCP(W)=338.79 8"VCP(E)=338.23 15"RCP(E)=338.79 / / / EX. 8" DIP SS Ir D� I I EXISTING - - -/ 4I III ►� I W. MORGAN ST. EX. SSMH / / (VARIABLE I f RIM=343.25- �4 I III I I IIII P'� ( BLE WIDTH PUBLIC R/ W) ++ 8"DIP(E)_333.06 8 DIP(W)=334.74 �4 I I III I N/F 10"DIP(16"ENCASEMENT)I II CROCKER FAMILY PROPERTIES, LL(S)=333.056 11/I ,I 615 W MORGAN ST I PIN 1703-48-1885 DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL ACCESSORY STRUCTURE NORTH BUILDING FFE=352.05 N/F GLENWOOD ONE OFFICE, LLC 1 GLENWOOD AVE PIN 1703-49-4101 DB 16926, PG 570 0.70 AC. ZONING: DX-12-UG, DX-12-UIL � N F � =:U_ ���' PRIVATE DRAINAGE 6 EASEMENT ` _ PREVIOUSLY APPROVED PROJECT ( ITV nr MAI nnu / tAS `LIMITS OF DISTURBANCE .( (TYP.) TEMPORARY DITCH TD-2 LINED WITH NqG ERONET C125 OR EQUIVALENT. ACCESSORYOSTRUCTURE SOUTH BUILDING 741�1 FFE=346.79 EX. PRIVATE DRAINAGE EASEMENT EX. SSMH RIM=343.38 8"DIP(E)=334.27 8"DIP(S)=334.27 _ss . I I I I I I 7 I / r� I' ---T-- ,--'o =Ri FxM 1541 RCP 1127 EROSION CONTROL LEGEND II�III�II' SILT FENCE OUTLET INLET PROTECTION INLET PROTECTION FOR EXISTING STRUCTURES TEMPORARY SLOPE DRAIN FILTER BERM CHECK DAM -SF -SF -SF- SILT FENCE -TP-TP-TP- TREE PROTECTION FENCE LD LD LIMITS OF DISTURBANCE IIIIIIIIIIIIIIIIIIII110 IIIIIIIIIIIIIIIIIIIII0 _11� IIIIIIIIIIIIIIIIIIII110 IIIIIIIIIIIIIIIIIIIII0 DIVERSION DITCH o Oo O° off°° (� O° ° o °° °Op°°°VVV°°�°vQn°° °°�°° CONSTRUCTION ENTRANCE/EXIT ° o 0o , o O�' �9b �o �� O v�0�� o °o °�� o ° ° °o o° CONTRACTOR'S MAINTENANCE PLAN: 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE DONE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. 2. TEMPORARY DIVERSIONS SHALL BE MAINTAINED DAILY BY THE CONTRACTOR SO THAT THEY ARE FUNCTIONAL AT THE END OF EACH WORKDAY AND WHEN STOPPING WORK FOR RAIN. 3. REMOVE SEDIMENT BEHIND SILT FENCE WHEN DEPTH REACHES 6 INCHES AT THE FENCE. REPAIR SILT FENCE AS NECESSARY TO MAINTAIN A BARRIER. 4. ALL SEEDED AREAS SHALL BE FERTILIZED, RE -SEEDED AS NECESSARY AND MULCHED ACCORDING TO PROJECT SPECS TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE GROWTH. 5. MAINTAIN TREE PROTECTION FENCING THROUGHOUT DURATION OF CONSTRUCTION. 6. ALL OPEN STORM PIPES MUST BE PROTECTED WITH STONE FILTER PROTECTION AFTER WORK STOPPAGE EACH DAY. SLOPES AND SURFACE STABILIZATION: 1. DURING ALL STAGES OF CONSTRUCTION, PERMANENT GROUND COVER OR OTHER DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION SHALL BE PROVIDED ON ALL DISTURBED AREAS WITHIN 14 DAYS FOLLOWING A TEMPORARY OR PERMANENT STOPPAGE 2. CUT AND FILL SLOPES SHALL BE STABILIZED WITHIN 14 DAYS OF ANY GRADING PHASE. 3. SLOPE EROSION CONTROL MATTING SHALL BE INSTALLED FOR TEMPORARY STABILIZATION DURING THE ESTABLISHMENT OF VEGETATIVE COVER ON ALL STEEP SLOPES (6:1 OR STEEPER). 4. INSTALL MATTING PER MANUFACTURER'S INSTRUCTIONS. STANDARD NPDES NOTES: 1. THIS PAGE IS SUBMITTED TO COMPLY WITH NPDES GENERAL STORMWATER PERMIT NCGO10000. 2. THIS PAGE CAN BE APPROVED BY THE CITY PURSUANT TO NPDES GENERAL STORMWATER PERMIT NCGO10000 ONLY. 3. THIS PAGE OF THE APPROVED PLANS IS ENFORCEABLE EXCLUSIVELY PURSUANT TO NPDES GENERAL STORMWATER PERMIT NCGO10000. 4. THE CITY IS NOT AUTHORIZED TO ENFORCE THIS PAGE OF THE PLANS AND IT IS NOT PART OF THE APPROVED PLANS FOR PURPOSES OF ENFORCEMENT ACTION UNDER THE CITY CODE. SEEDBED PREPARATION: 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL THREE INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO SIX INCHES DEEP. r 3. REMOVE ALL LOOSE ROCK, ROOTS AND OTHER OBSTRUCTIONS, LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. r ' 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED FOUR TO SIX INCHES DEEP. 7 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE MORE THAN 60% DAMAGED, RE-ESTABLISH FOLLOWING THE ORIGINAL LIME, FERTILIZER AND SEEDING RATES. i/ 9. CONSULT S&EC ENVIRONMENTAL ENGINEERS ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. 1 m ' C - f01s - �Gs�X-15-GS sP- -as"S _ _ - - - , - Jl LI�i sn -� _ _ _ EX. 3 - 6 / wv g I � T/C=345.37 I I I I -W w w o 15"'RCP(E) 339.17 L J W w W15"RCP(W)=339.07 / EX. CB vNi o �LW W W EX. JB T/C=343.13 a I R M 343.07/ I ` 15"RCP(N)=337.37 15"RCP(S)=337.27 15" RCP(NE) 335"16 I W I EX. JB 15" RCP(E) 336.16 �� �■ RIM=342.90 w w I 15 RCP(W)=336.16 I - 15"RCP(N)=336.93 12 PVC(NW)=339.21 15"RCP(W)=336.93 18" RCP(S)=336.06 15"RCP(E)=336.93 EX. SSMH EX. 8" DIP SS RIM=342.98 - - _ 8"DIP(N)=333.68 -�� -rrnl- ----- 8„DIP(W)=333.48as as ---_----_ - --- ss ss = - - - - CO � IL_ J I I I I I • I - - RALEIGH HOTELF GROUP, LLC - - -� - -"'�- �� 344 L 1- _ I �� 603 W MORGAN ST Cr I _ - - - _ PIN 1703-48-4920 �1 DB 16986, PG 2031 0.23 AC. ZONING: DX-7-UL ALL CONSTRUCTION SHALL BE IN SEE SHEET C-2 FOR ALL PROJECT, ACCORDANCE WITH THE CURRENT CITY SITE, GRADING, STORM DRAINAGE AND OF RALEIGH ENGINEERING DESIGN AND UTILITY NOTES CONSTRUCTION STANDARDS NPDES GROUND STABILIZATION SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES 7 DAYS NONE AND SLOPES HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE IF SLOPES ARE 10' SLOPES STEEPER OR LESS IN LENGTH THAN 3:1 7 DAYS AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR 7-DAYS FOR SLOPES FLATTER 14 DAYS GREATER THAN 50 FEET IN LENGTH ALL OTHER AREAS NONE (EXCEPT FOR WITH SLOPES 14 DAYS PERIMETERS AND HQW FLATTER THAN 4:1 ZONES) *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. DISTURBED AREA = 2.00 AC. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 HERITAGE a� - Y PROPERTIES, INC IIII- w /) (L V z� U w oc w M o rZ I r4 M �'7=z 00 zc�J �OU V Q== O °COor_ J 0 CO 0 m z z 0 (D LLJ J Um< N�N c'V z O U CAS At- � 'at- . S. S\-P..``��� REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-EC4 CHECKED BY CHT DRAWN BY CHT SCALE I"=20' DATE 12. 15. 2018 SHEET NPDES EROSION CONTROL PLAN EC-4 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION \ \\\ CLASS 1 RIP RAP 1 HEADWALL INVERT PIPE / a #57 WASHED STONE. 1' THICKX 3' HIGH MIN. � MAINTENANCE: / REMOVE SEDIMENT & RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSION PLAN VIEW WHEN SEDIMENT HAS ACCUMULATED TO 112 NOTE: DESIGN DEPTH OF THE TRAP. NO SCALE IF EXCAVATED STORAGE AREA IS USED AS TEMPORARY SEDIMENT TRAP, THE DESIGN CRITERIA FOR TEMPORARY SEDIMENT TRAP MUST BE SATISFIED. ANY RIP -RAP DISPLACED FROM THE STONE HORSESHOE MUST MAX DIA PIPE IS 36' BE REPLACED IMMEDIATELY. RIP RAP HEADWALL (1' MIN HEIGHT FROM ROAD SHOULDER). -1 NATURAL 111I T GA car GROUND ] -Ili A70wMINIMU ) O FLOW -IIIII- I FILTER FABRIC =1 II= CLASS 1 RIP -RAP n n O y k57 WASHED STONE. 1' MIN THICKNESS. oxi O O v m CROSS SECTION NO SCALE 2 ROLLMA)CH ROLLED EROSION CONTROL Specification Sheet - EroNet- C125"' Erosion Control Blanket DESCRIPTION Indexr r-rty Test Method Typical The long-term double net erosinn control blanket shall he a machine C.22 in. produced mat of 7001/o coconut fiber with a functional longevity of up Thickness ASTM 06525 (5.59 mm) to36months. (NOTEfunctional longevity may vary deperdingUpon Resiliency ECT:Guidelines 82% Tlimatic conditions, soil, geographical location, and elevation). The WaterAbsorhency ASTM 07117 1671h htanket shall he of cansistert thickness with the coconut evenly MasslUnit Area A5TM 5475 7,73 oz(sy distributed over the entire area of the mat. The blanket shall be (262.8 gJsm) covered on the top and bottom sides with a heavyweight photode- Swell ECTC Guidelines 13% gradable polypropylene netting having ultraviolet additives to delay Smolder Resistance ECTC Guidelines Yes breakdown and an approximate 0.61 x 0.63 in (1.59 x 1.59 Len) mesh. Stiffness ASTM 01388 0.75 oz-in The blanket shall he sewn together on 1,50 inch (3,81 cm) centers with Light Penetration ASTM 06567 16 6% degradable thread. The blanket shall be manufactured with a colored 472.81hs/ft thread stitched alonghoti-I outer edges (approximately 2-5 inches g PP Y Tensile Strength - MD ASTM D5818 (7,01 kN/m) [5-12.5 cm] from the edge) as an overlap guide for adjacent mats, Elongation - M13 ASTM D5818 25.691b 223ft The C125 shall meet Type 4 specification requirements established by Tensile strength - TD ASTM 36818 (3.35 kN/N(m) the Erosion Contral Technology Council (ECTC) and Federal Highway Administration's (FHWA) FP-03 Section 711.17 Elongation - TD ASTM 05818 33.9% Material Content Biomass Improvement ASTM 7322 257% 0.5 cos/sq yd MatriX i00%Coconut Fiher (0,27kg/sm) Design Permissible UnvegetatedShear Stress 2.25psf(108Pa) Heavyweight phowdegradable 3 Ibs/1000 sq ft Unvegetated Velocity 10.0 fps (3.05 m/s) Netting with UV additives (1.47 gJsm) Thread Black polypropylene SlopeDesign Data: C Factors Slope Gradients (S) Standard Roll Sizes Slope Length (L) _ 3:1 31 - 2.1 > 2:1 Width 5.67 (2.03 m) 9 ft (2.44IT) 120 ft 16 m) 0.001 C.029 0.082 Length 108 ft (32.02 m} 112 ft (35.14 m) 20-50 ft 0,036 0.060 0,096 Weight t 10 % 44Iha (19.95 kg) 56.25 (25.5 kg) _ 50 ft (15.2 m) 0.070 0.090 0.110 Area 80 sq yd (66.9 sm) 100 sq yd (83.61 sm) Flow Depth Manning's n <_ 0.50 ft (0.151 0.022 0.50 - 2.0 ft 0.022-0.014 a2.0ft(0.60m) 0.014 Tensar lmtrmatmal cnrpmradonwarrants that at the tlrm of delivery the product iurdshm Tensar International Corporation hemundershali od- tothespeJTaadonAatedheremAllyahe•warrantyintluding 2500NorthwindsParkwa �ananrirtyandot'rests`ahispgFp�rp r1. nerehyexcrto l a!Iat .T Tensar Y doesnotelApp du,t at onthis the Lout Ten ar is pmdud sareo on5up Tensar SUltP 500 will replace the product at rw cost To the cusdcmer This produRsperi5ration supersede Alpharetta, GA30009 WI prior9-iiiraHo %rthtl pedurtdasrrihedahoveandT,-tappiirahletosny NORTH AMERICAN GREEN' BOOTENSAR-1 podurts:Mpped pram to lan.N 1, 1012. tensarcorp,com 0209, Tensar International Corporation EC_RMX_MnDS_EC725_5.13 1•+ TREE PROTECTION AREA e DO NOT ENTER WARNING SIGN DETAIL STEEL POST WOVEN WIRE FABRIC WARNING SIGN MIN. 10 GA. LINE WIRES FILL SLOPE N GRADE MIN o IIII H 4' MIN SILT FENCE GEOTEXTILE FABRIC SIDE VIEW rry IIII MIN. 12-IJ2 CA INTERMEDLAT- i1,WIRES �■TREE r___-1■■■■IIIII PROTECTION AREA DO NOT 1�►�!�!j��!���dl E, 110,11, 01i►�:�:i If, r TO SECOND FROM• •.�III r.•:� O►i`�WIRE D�i�►�i�i���i�i►111 i�i�i�i�i��i'IIGRADE IIII RIII FRONT VIEW IIII IIIII - IITI IIII - 'IIII = MAINTENANCE: CLEAN OUT AT 50% CAPACITY LIFE OF FENCING: 6-9 MONTHS NOTES: 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 2. LETTERS TO BE W HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 3. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND WON CENTER THEREAFTER. 4. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 5. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 6. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 7. ADDITIONAL SIGNS MAY BE REQUIRED BY CITY OF RALEIGH INSPECTIONS DEPARTMENT BASED ON ACTUAL FIELD CONDITIONS. B. FLOW SHALL NOT RUN PARALLEL WITH THE FENCE. 9. END OF SILT FENCE NEEDS TO BE TURNED UPHILL. 10. SEE N.C. STATE DENR PRACTICE STANDARDS & SPECIFICATIONS SEDIMENT FENCE SET FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING CONSIDERATIONS & DESIGN CRITERIA. (HOWEVER FLOW SHALL NOT RUN PARALELL WITH THE TOE OF THE FENCE). SECTION VIEW STANDARD METAL POSTS (MINIMUM LENGTH 5') 2'-O" IN GROUND 1 ONCRETE"' r BLOCKS ,,HARDWARE WIRE #57 WASHED STONE 6-4- 2'BURY IN SOLID GROUND GALVANIZED HARDWARE WIRE EXTENDS TO THE TOP OF BOX. (19 GUAGE, Y" MESH OPENINGS.) Og o• Uo o 0 0 0 0 °° o o �0 0 2: 1 0 goP o CO , o0 00 -a�o� o'o '00 0 �0 0 -- a O OO o �0 B o 0 00 0 0 o °o V o° 0 0 0 ��o o � o � o� o o oo oDoo-U ° 000 00 oQ ��gog�o�o4 ao 57 WASHED STONE PLACED AGAINST HARDWARE IRE TO A HEIGHT OF 16" MIN. ABOVE TOP OF BOX. DRAINAGE AREA =1 ACRE (MAXIMUM). 2' MIN COMPACTED 2' MIN A` -IIIII=IIIII=IIII'- STEEP CUT OR FILL SLOPE- 6' TYPICAL I- � I I-IIII l III„ -III ORIGINAL GRADE CROSS SECTION NOTE: AT A MINIMUM, SEED, STRAW & TACK REQUIRED FOR SITE INSPECTION APPROVAL. SEE N.C. DENR EROSION and SEDIMENT CONTROL PLANNING and DESIGN MANUAL FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING CONSIDERATION & DESIGN CRITERIA. STABILIZE DIVERSION DITCH BASED ON DESIGN VELOCITY. 50' MIN. AND SUFFICIENT TO KEEP SEDIMENT ON SITE 00 0 0 0 0 000��0 OOOO OS 0 04'0 0000/0000 00 0 0�0 0 00 � o 00 0 0 00 25' OR FULL WIDTH z o 00 3" - 4" STONE TO BE USED g o OF PROPOSED STREET O U) o0 ( SURGE STONE OR 000 OR ENTRANCE, O o0 0o RAILROAD BALAST) �o o WHICHEVER IS 00 Oo o 000 0 0 $000 GREATER. 1 0 00a7 oo O O 00oO p%p o0 0p 000 000 0 000000o0000s0000000000v0000 * PLAN SILT FENCE TOP OF SILT FI MUST BE AT LE ABOVE THE TIC THE WASHED 1 NOTES: 1. SILT FENCE SHOULD BE INSTALLED TO ENSURE CONSTRUCTION ENTRANCE IS USED. 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE STONE, THEN THE TIRES OF THE VEHICLE MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD OR THE LENGTH OF THE CONSTRUCTION ENTRANCE EXTENDED. EXISTING ROADWAY \ 35' MIN. 6"MIN. 000000p0000008ot00000 00 00 0 0 0 0 �'111-IIIII- ''III=IIIII I11- FABRIC UNDER STONE NOTES: 1. REMOVE SEDIMENT WHEN HALF OF STONE OUTLET IS COVERED. 2. REPLACE STONE AS NEEDED TO ENSURE DEWATERING. CROSS SECTION STEEL POST WOVEN WIRE FABRIC HARDWARE CLOTH � NEW CONSTRUCTION 15' MIN. �4'008�0 o goo0 00 12' MIN. ��� �� IIIII�II►'' I-IIIII=IIIII= IIIII= MAINTENANCE: ADD ADDITIONAL STONE AND'FL UFF" TOP DRESSING WITH 2' STONE. SEE N.C. DENR EROSION and SEDIMENT CONTROL PLANNING and DESIGN MANUAL FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING CONSIDERATION & DESIGN CRITERIA u FILTER FABRIC, V� AND HARDWARE STEEL POST SET CLOTH IN TRENCH. MAX 7 APART MIN 2' INTO SOLID GROUND FILTER • r•Y� WASHED • ,.�.�,....• .•.� •.,,�•.:a• ,�&FILTER FABRIC APRON -11 -11 STEEL POST WOVEN WIRE FABRIC 4 N FILL SLOPE M GRADE 6' MIN 4 \ N =MIN `SILT FENCE GEOTEXTILE FABRICk MAINTENANCE: CLEAN OUT AT 50%. CAPACITY LIFE OF FENCING: 6-9 MONTHS SIDE VIEW 8 MAX' PLASTIC OR VARIABLE AS DIRECTED BY THE ENGINEER WIRE TIES TM MIN. 10 GA. 11 MIN. 12-V2 GA. LINE WIRES INTERMEDIATE WIRES AI 04= GRADE b m f/ o=IIIII-1 I1111Mlll 111 y � I Cn�FRONT m I 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HE '� `�_ r• PROPERTIES, INC LU /W V z� U w - W m M V = z 00 z � J �:O� VQCC- O o� = J 0 W O CID z � z O J (D REVISIONS N0. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATIONEC�5 PROJECT NO. HTG-17000 FILENAME HTG17000-EC5 CHECKED BY CHT DRAWN BY CHT SCALE NTS DATE 12. 15. 2018 SHEET EROSION CONTROL DETAILS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION WOODEN STAKE WITH WATTLE FILTER FABRIC ANCHORED TO THE TOP 12" DIAMETER STRAW FILLED WATTLE OR DITCH LINER DITCHLINE NOTES: 1. WATTLES SHALL BE FILLED WITH STRAW OR OTHER APPROVED MATERIAL 2. SPACING FOR WATTLES SHALL BE PROFILE VIEW DETERMINED BY THE SITE ENGINEER. 3. WATTLES MAY BE USED FOR PROTECTION OF CATCH BASINS AND DROP INLETS WITH APPROVAL BY THE STORMWATER UTILITY MANAGER OR DESIGNEE. 12" DIAMETER STRAW FILLED WATTLE FASTENED TO WOODEN STAKE BY NAIL OR STAPLE m WOODEN STAKE 5 — DITCHLINE FILTER FABRIC OR DITCH LINER Wfty FLOW 8" FABRIC STAPLE 18, 18" 6" COVER LENGTH AS RY_\ TO EXTEND THRU DIKE EARTH DIKE 4' MIN. PIPE I� 1.5' MIN. 12 FLEXIBLE PIPE _ _-III-III-III-III-I � �-� i l� TIE DOWN 10' MAX. SPACING III I I--111-1II I I 111=111-11I _II1- '' TIE DOWN AT END —1 4' (MIN)* I DIAMETER (D) _ PROFILE IIIII -1 II I I II 111 * AT LESS THAN 1 % SLOPE CONSTRUCTION SPECIFICATIONS: 1. THE TOP OF THE EARTH DIKE OVER THE INLET PIPE AND THOSE DIKES CARRYING WATER TO THE PIPE SHALL BE AT LEAST 1.5 FEET HIGHER AT ALL POINTS THAN THE TOP OF THE INLET PIPE. 2. THE PIPE SHALL BE FLEXIBLE WITH WATER TIGHT CONNECTING BANDS. FLEXIBLE PIPE SHOULD BE STAKED ON EITHER SIDE. 3. A RIP RAP APRON SHALL BE PROVIDED AT THE OUTLET, IF EMPTYING INTO A DISTURBED AREA. 4. THE SOIL AROUND AND UNDER THE INLET PIPE AND ENTRANCE SECTION SHALL BE HAND TAMPED IN 4" LIFTS TO THE TOP OF THE EARTH DIKE. 5. FOLLOW-UP INSPECTION AND ANY NEEDED MAINTENANCE SHALL BE PERFORMED AFTER EACH STORM BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT. TEMPORARY SLOPE DRAIN N.T.S. PVC END CAP \ SCHEDULE40 PVC VENT PVC PIPE PVC ELBOW i/ WATER SURFACE D PVC END o CAP SCHEOULE40 PVC PIPE PVC TEE ORIFICE PLATE C PIPE FLEXIBLE 1¢' HOLES IN HOSE PVC TEE UNDERSIDE OBOTTOM SURFACE END VIEW FRONT VIEW ARM ASSEMBLY o m � o y O cZiJ "C" ENCLOSURE c S $. `C O (A 25x PERSPECTIVE VIEW o WATERENTRY K mi�t N ITT v T` O W Tn zo t7 m= NOTE: SKIMMER TO BE TETHERED i m 1 SEE N.C. DENR EROSION and SEDIMENT CONTROL PLANNING and DESIGN MANUAL FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING CONSIDERATION & DESIGN CRITERIA. F. DESIGN CRITERIA SUMMARY: PRIMARY SPILLWAY: MAXIMUM DRAINAGE AREA: MINIMUM SEDIMENT STORAGE VOLUME: MINIMUM SURFACE AREA MINIMUM LAN RATIO: MAXIMUM LAN RATIO: MINIMUM DEPTH: DEWATERING MECHANISM: MINIMUM DEWATERING TIME: BAFFLES REQUIRED: DESIGN LIFE: DAM HEIGHT: TEMPORARY SEDIMENT BASIN Rig RI BARREL PIPE 100 ACRES MA%. 1 SOD CUBIC FEET PER ACRE OF DISTURBED AREA 435 SQUARE FEET PER CFS OF PSMNFLOW 2:1 6:1 2 FEET SKIMMER ATTACHED TO BOTTOM OF RISER 24 HOURS 3 MINIMUM 3YEARSMAX 15 FEET OR LESS FROM TOP OF DAM TO LOW POINT OF DOWNSTREAM TOE. SEE NC DENR EROSION and SEDIMENT CONTROL PLANNING and DESIGN MANUAL. U CREST WIDTH 9'-16" STONE WIFABRIC y ME�G�Nc� E MIN. SIZE 15'CMP 12" SMOOTH WALL1_ O W BAFFLE (TYP.) TETHER AC1�b :STONE ENERGY 7i DISSIPATOR 'G�p _ PERSPECTIVE VIEW INLET ZONE 35% OF SURFACE AREA FIRST CHAMBER 25% OF SURFACE AREA SECOND CHAMBER 25% OF SURFACE AREA EXTEND BAFFLES UP SIDES AS TO NOTALLOW FLOW AROUND THE ENDS. SUPPORT ROPE TO WIRE TO SUPPORT POST PREVENT SAGGING 24'oN SID sue' BAFFLE DETAIL 4'MAX STAKE TO SUPPORT WIRE T MIN COIR MESH OR JUTE, TRENCHED DES ON LIFE OF FABRIC INTO BOTTOM AND SIDE IS a-12 MONTHS 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 * HERITAGE J PROPERTIES, INC L U ,, V 11 ( V z�__ U LU LU M lD I N M V = z 00 z J �0< re VQ= O °C0� J 0 m 0 m z z 0LU _J_C� J U Z) m N A ' l , vI z 0 U ,,,,, 11111111/IT",I �N CARS,, SEA'__ � Or'109 i�� 141 a %;S'. S. S�-P /11111ts0** REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-EC5 CHECKED BY CHT DRAWN BY CHT SCALE NTS DATE 12. 15. 2018 SHEET EROSION CONTROL DETAILS EC-6 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 0 2 0 3 0 4 0 5 D 0 C 0 B 0 A a-i (3) NYS SYL o I (3) PIS CHI r g F � g s I � � � o (2) PIS CHI _ cn I � � U' SD wv o W D U U w do �D (3) NYS SYL f-77 o w f 771 i H H G G SS SS SS SS LD LD H (3) QUE BIC (2) ULM PAR (2) QUE BIC PLANTING SCHEDULE - CONTRACTOR SHALL SATISFY ALL MEASUREMENTS INDICATED SYM QTY BOTANICAL NAME COMMON NAME MIN. CAL/RT MIN. HT. MIN. SPR. SPACING REMARKS STREET TREES LIRIODENDRON STRONG CENTRAL LEADER; EVENLY LIR TUL 4 TULIPFERA TULIP POPLAR 3" 10, 5' AS SHOWN BRANCHED; FULL STRONG CENTRAL LEADER; EVENLY NYS SYL 6 NYSSA SYLVATICA BLACK GUM 3" 10' 5' AS SHOWN BRANCHED; FULL STRONG CENTRAL LEADER; EVENLY PIS CHI 5 PISTACIA CHINENSIS CHINESE PISCTACHE 1.5" 10' 5' AS SHOWN BRANCHED; FULL AMENITY AREA TREES MAG LOE 1 MAGNOLIA X LOEBNER N/A 8' 4" AS SHOWN STRONG CENTRAL LEADER; EVENLY LOEBENERI 'MERRIL' MAGNOLIA BRANCHED; FULL LIRIODENDRON STRONG CENTRAL LEADER; EVENLY QUE BIC 5 TULIPFERA TULIP POPLAR 6" 16' 6' AS SHOWN BRANCHED; FULL STRONG CENTRAL LEADER; EVENLY ULM PAR 2 ULMUS PARVIFLORA CHINESE ELM 5" 14' 5' AS SHOWN BRANCHED; FULL I J LLD LD \ T. P � Ir 0 I (2) LIR TUL (1) MAG LOE - — SS Co /)T /AA- r 44s- a, as (1) LIR TUL (1) LIR TUL wl� al ai ai o Un SS SS n�-n n- -- -- 7 Ss = (IS � (IS � I � 0 I I I L 1 I°I _L I°I 1 I � — �T - M Wei M So SS SS o�� �— as GENERAL NOTES 1. LOCATION AND TOPOGRAPHICAL INFORMATION WAS TAKEN FROM AN ACTUAL FIELD SURVEY DATED XX-XX-XXXX. SURFACE 678 ASSUMES NO RESPONSIBILITY FOR DESIGN OR CONSTRUCTION CHANGES CAUSED BY INACCURACIES IN SURVEYS. 2. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION. 3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR ADHERENCE TO ORDINANCES, REGULATIONS, LAWS AND CODES HAVING JURISDICTION OVER THE PROPERTY PRIOR TO COMMENCING WORK. 4. ALL MATERIALS, CONSTRUCTION, AND WORKMANSHIP SHALL MEET THE, CITY OF RALEIGH SPECIFICATIONS AND DESIGN STANDARDS. 5. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD PRIOR TO BEGINNING WORK. CONTRACTOR SHALL CONTACT NC ONE CALL CENTER AT 1-800-632-4949 FOR LOCATION OF EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN WORKING AROUND EXISTING UTILITIES TO REMAIN. 6. ALL WORK WITHIN THE NCDOT ROW SHALL CONFORM TO NCDOT STANDARDS AND SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN ALL NEEDED PERMITS, AGREEMENTS AND SUPPLY NOTIFICATIONS OF CLOSURES FROM THE NCDOT. 7. CONSTRUCTION STAKEOUT FOR THIS PROJECT SHALL BE PROVIDED BY THE CONTRACTOR USING A DIGITAL (CADD) FILE PROVIDED THROUGH THE ARCHITECT/GC. THE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES FOUND BETWEEN THE DIGITAL FILE AND THE STAKING DIMENSIONS SHOWN ON THE PLAN OR DISCREPANCIES FOUND BETWEEN THE LAYOUT AND THE SITE. ANY MODIFICATIONS MADE BY OTHERS TO THE DIGITAL FILE PROVIDED SHALL RENDER IT VOID. IN THE EVENT OF DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND THE DESIGN LAYOUT OR EXISTING CONDITIONS, THE CONTRACT DOCUMENTS TAKE PRECEDENCE OVER THE DIGITAL FILE. 8. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVING FOR ELECTRIC, DRAINAGE, AND UTILITIES PRIOR TO THE INSTALLATION OF COMPACTED SUB -GRADE, SUB -BASE AND PAVEMENT AS NECESSARY. SLEEVES TO BE INSTALLED AT A MINIMUM DEPTH BELOW GRADE AS PER LOCAL CODES. 9. ROADWAYS AND BUILDINGS MUST BE CAPABLE OF SUPPORTING FIRE AND EMERGENCY APPARATUS DURING CONSTRUCTION. 10. SEE CIVIL SHEET FOR SEDIMENTATION AND EROSION CONTROL MEASURES. 11. SEE CIVIL SHEET FOR UTILITY AND UNDERGROUND STORM DRAINAGE INFORMATION. LANDSCAPE NOTES 1. THE PLAN DEPICTS REQUIRED PLANTING BY THE CITY OF RALEIGH 2. ALL CONSTRUCTION TO CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RALEIGH 3. PLANT LIST IS PROVIDED FOR CONVENIENCE ONLY. IN THE CASE OF DISCREPANCIES BETWEEN THE PLAN AND PLANT LIST QUANTITIES, THE PLAN SHALL TAKE PRECEDENCE. 4. AFTER THE SITE IS STABILIZED AND FREE OF SEDIMENTATION, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL DEVICES, SILT, RIP RAP AND TEMPORARY STONE STAGING AREAS FOR REPLACEMENT WITH PLANTING SOIL. PROVIDE PLANTING ACCORDING TO THE LANDSCAPE PLAN. 5. TEMPORARY EROSION CONTROL SEED MUST BE FULLY REMOVED PRIOR TO PREPARATION OF PERMANENT SEED, SOD OR LANDSCAPE BEDS. 6. UNLESS OTHERWISE NOTED IN THE PLANT LIST, THE CONTRACTOR SHALL OBTAIN AND INSTALL ONLY PLANT MATERIAL THAT IS GROWN ON ITS OWN ROOT -GRAFTED OR BUDDED PLANT MATERIAL WILL BE REJECTED. 7. ALL TREES SHALL BE OBTAINED FROM THE NURSERY WITH EXPOSED ROOT CROWNS. B&B MATERIAL DELIVERED TO SITE WITH BURIED OR RECENTLY BURIED ROOT CROWNS WILL BE REJECTED. 6. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF PLANT SUBSTITUTIONS IN ANY MEASUREMENT OR SPECIES INDICATED. SEE SPECIFICATIONS FOR FULL NOTIFICATION REQUIREMENTS. 7. DO NOT PLANT IN STORM WATER CONVEYANCE SWALES OR PROVIDE FINE GRADING THAT DISRUPTS FLOW OR CHANGES LONGITUDINAL SLOPES. 8. PLANT THE OUTER EDGES OF EACH PLANTING GROUP FOLLOWING THE BED OUTLINE ACCORDING TO THE PLAN. ONCE A SATISFACTORY MATCHED OUTER SHAPE IS OBTAINED, FILL THE CENTER OF EACH AREA WITH PLANTS ACCORDING TO THE PLAN AND SPACING NOTES. 9. THE PLANTING LAYOUT WITHIN PLANTING BEDS SHOULD BE SHIFTED TO MINIMIZE CONFLICTS WITH EXISTING TREE ROOTS. 10. DISTURBED EARTH AREAS BEYOND PROJECT LIMITS THAT ARE DIRECTLY CAUSED BY CONTRACTOR MEANS AND METHODS SHALL BE RESTORED WITH TURF SOD; UNLESS OTHERWISE NOTED. 11. STREET TREES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 2 OF THE CITY TREE MANUAL. N SCALE: V = 20'-0" 0 10 20 40 ii r a Surface 678, P.A. 215 Morris Street, Suite 150 Durham, NC 27701 www.surface678.com p : 919-419-1199 f : 919-419-1669 CONSULTANTS REGISTRATION C A R -,!e *e C-098 c*- A a;. �,p,•.� Q��. - M07 FoLM CoH87�c� �7oo� CLIENT F'{ HERITAGE �T PROPERTIES, IN HERITAGE PROPERTIES, INC. 501 FAIRMOUNT AVENUE, SUITE 101 TOWSON, MD 21286 TWO HILLSBOROUGH RALEIGH, NC KEY MAP NO. REVISION DATE ISSUE: ADMINISTRATIVE SITE REVIEW PROJECT NO: DATE: NOVEMBER 7, 2018 DRAWN: RS, YW CHECKED: CB SHEET TITLE: LANDSCAPE PLAN F L S-1 1 0 2 0 3 07 0 5 Surface u 0 0 0 0 ninTC0. 1. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE DRAINAGE OF ALL PLANTING PITS. (POSITIVE DRAINAGE AWAY FROM PIT) 2. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 3. STREET TREES MUST BE 3" CALIPER AT INSTALLATION WITH A S MINIMUM FIRST BRANCH HEIGHT. 4. PLANTING SEASON OCTOBER - APRIL. 5. A TREE IMPACT PERMIT IS REQUIRED. 6. ELECTRICAL OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE PLANTING AREA IMMEDIATELY SURROUNDING THE TREE. ninTGc• �0 NOT PRUNE LEADER. PRUNE OR CUT ONLY )EAD OR UNHEALTHY BRANCHES 'ROVIDE STAKING IF SPECIFIED. IF STAKING IS 'ROVIDED, PROTECT TREE WITH BROAD STRAP OR =LEXIBLE TUBING. ALLOW FLEXIBILITY IN STRAPS f0 DEVELOP TRUNK TAPER. PROVIDE TURN 3UCKLE AND WARNING FLAGS. REMOVE ALL STAKING AND ACCESSORIES WITHIN ONE YEAR :ROM PLANTING. THE ROOT FLARE SHALL BE PLANTED AT GRADE, NO HIGHER THAN 2" ABOVE GRADE, AND NEVER BELOW GRADE. REMOVE EXCESS SOIL TO EXPOSE THE ROOT FLARE AT GRADE. TREE SHALL BE SET PLUMB MULCH DEPTH 3". KEEP MULCH 3" FROM ROOT FLARE AND DO NOT CONTACT STEM HIGH QUALITY SOIL MIX AS SPECIFIED WATER SAUCER SHALL BE NO MORE THAN 3" ABOVE GRADE COMPLETELY REMOVE TOP HALF OF BURLAP, LACING AND WIRE BASKET AND DISCARD FROM HOLE ROOT BALL SHALL BE PLACED DIRECTLY ON COMPACTED SUBGRADE. HANDLE TREE BY THE ROOT BALL ONLY. CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV CITYOFRALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPT REVISIONS DATE• 911113 NOT TO SCALE TREE PLANTING DETAIL PRCR-03 MULCH 3" DEEP MIN. AND 6" MIN. FROM THE BASE OF THE TREE SIDEWALK PAVING AND SUBBASE PLANTING SOIL MIX AS SPECIFIED 4" DIA. PVC PIPE WRAPPED IN FILTER FABRIC AND CONNECTED TO STORM DRAINAGE SYSTEM COMPACTED OR UNDISTURBED SUBGRADE 1. A SITE SPECIFIC PLAN MUST BE DEVELOPED TO ENSURE THAT: 1.1. EACH TREE IS PROVIDED A MIN. ROOT -ACCESSIBLE SOIL VOLUME OF 600 CUBIC FEET OR A MINIMUM OF 6 ROOT PATHS. 1.2. THE TREE ROOT AREA BENEATH THE SIDEWALK IS EXPANDED TO MAXIMIZE ROOT ACCESSIBLE SOIL SPACE UNDER THE PAVEMENT. 1.3. CONNECT SOIL SPACE FOR ROOT EXPANSION WHERE POSSIBLE TO ALLOW ROOT SYSTEMS OF TREES TO OVERLAP AND COLONIZE A SHARED SOIL SPACE. 1.4. ANY COMBINATION OF STRUCTURAL SOILS, SOIL CONTAINMENT SYSTEM (e.g., SILVA CELL), OR ROOT CHANNELING (e.g., SOIL STRIP DRAIN/AERATION SYSTEM) THAT PERFORMS AS SPECIFIED IS ACCEPTABLE. 3. 40' X 6' WIDTH MINIMUM APPLIES TO BOTH STRUCTURAL SOILS AND SUBSURFACE SOIL CONTAINMENT SYSTEMS. 4. SUBSURFACE APPLICATION SHALL BE REVIEWED AND APPROVED BY CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES URBAN FORESTRY DIVISION PRIOR TO INSTALLATION. STRUCTURAL SOIL SYSTEM CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GOV WWW.RALEIGHNC.GOV L GREY IRON, RECTANGULAR 4'X6', 1.5" MIN. THICK, WITH 112" OPENING OR LESS NOTES: 001WOFX�®4 I j f� 2. GENERAL PATTERNS TT RN DESIGN MUSGTE DESIGN MUT BE ADA T AS SHOWN. ``,a 3. EXCEPTIONS OR PERSONALIZATION MUST BE REVIEWED AND APPROVED BY THE CITY OF RALEIGH. 4. A TREE IMPACT PERMIT IS REQUIRED. 5. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 6. ELECTRIC OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE GRATE AREA. /��I\\ ` CONTACT INFORMATION: I \ \� \ CITY OF RALEIGH PARKS, RECREATION AND CULTURAL r h\\\\\wpe \ RESOURCES DEPARTMENT URBAN FORESTER:TREES@RALEIGH NC.GOV WWW.RALEIGHNC.GOV (3 3I8' rKAME 721 /4" FRAME 36" W LL e O L ALL SLOTS ARE Y4" WIDE MAX. eh m I m BOLT TREE GRATE HALVES TOGETHER wl (2)1/7-13 x 3" STNL. STL. HEX BOLTS, GALV. FLAT WASHERS AND STNL. STL. HEX NUT f 7' 11/4" 314" _ " 4 3A" 6 m NOTE: ALL DIMENSIONS SHOWN ARE IN ENGLISH MATERIAL: CAST GRAY IRON ASTM A48, CLASS 35B FINISH: NO PAINT WEIGHT: 608#ISET w a CO J J U.] 0 CO CID FRAMES ARE ASSEMBLED USING A6"X11/4"X114" THICK STEEL PLATE BOLTED TO FRAME wl (2 3/8-16UNC .11 1112" X 1 STNLS STL. LAT HD. CAP SCREWS BOLTED PLATE (2) 318-16UNC TAPPED HOLES ASSEMBLY DETAIL Surface 678, P.A. 215 Morris Street, Suite 150 Durham, NC 27701 www.surface678.com p : 919-419-1199 f : 919-419-1669 CONSULTANTS REGISTRATION CAR . ..;,Cl E A ......... 4*•• �� ��i . Q. *° C-098 cE 6�10'%% M07 FOLM C0H87�UC7�o� CLIENT HERITAGE PROPERTIES, INC HERITAGE PROPERTIES, INC. 501 FAIRMOUNT AVENUE, SUITE 101 TOWSON, MD 21286 TWO HILLSBOROUGH RALEIGH, NC 11 G' NO. REVISION DATE ISSUE: ADMINISTRATIVE SITE REVIEW PROJECT NO: DATE: NOVEMBER 7, 2018 DRAWN: RS, YW CHECKED: CB SHEET TITLE: DETAILS LS-2 v C U v E LID m 7ii V 00 CD ti c�}R9 2,y�o VARIABLE WIDTH DEPENDENT ON GRASS STRIP WIDTH EXPANSION JOINT 2- a0�.Q5�G /o elpooa y\o��a.N� ✓Qryr J�p� B.5' 1 112^ EXPANSION JOINT MAXIMUM g c ad°o°°8• vo EXPANSION JOINT SEE T-10.01,2 FOR ADDITIONAL NOTES 6" EXPANSION JOINT SLOPE 114"IFT (MAX) 7.5" 6" SIDEWALK 7" 6" 2' 6.5' 6' SHEET I OF2 CITY OF RALEIGH STANDARD DETAIL USE 6.5" WHEN DRIVEWAY IS USED IN LIEU REvisrolvs ORTEE1111a MOTTOSCglE OF A WHEELCHAIR RAMP TO ACCOMMODATE 12:1 MAXIMUM SLOPE (ADA COMPLIANT), DRIVEWAY AND SUCH AS IN A CUL-DE SAC. SIDEWALK DETAIL T-10.01.1 FULL DEPTH CUTS HALL BE MADE GUTTER LINE PORTION TO REMOVED IF THE FINAL LIFT OF ASPHALT HAS BEEN INSTALLED AND IS DAMAGED DURING CURB REMOVAL, A ONE FOOT WIDE SECTION OF ASPHALT SHOULD BE SAWCUT AND REMOVED FOR FORMS TO BE USED TO KEEP A STRAIGHT EDGE ON THE DRIVEWAY APRON, REINSTALL HOT MIX SURFACE ASPHALT PATCH S9.56. IF THE FINAL LIFT OF ASPHALT HAS NOT BEEN INSTALLED, THE ASPHALT IN FRONT OF THE APRON CAN REMAIN IN PLACE. NOTES: 1. CURB AND GUTTER SECTION SHALL BE REMOVED IN ACCORDANCE WITH DRIVEWAY WIDTH APPROVED BY THE CITY- 2- IF PERPENDICULAR CUT IS LESS THAN 5' FROM NEXT JOINT, THEN THE PARALLEL CUT SHALL BE MADE TO THAT JOINT. 3, THIS METHOD IS NOT ALLOWED IN NEW ROADWAY CONSTRUCTION, PAY LIMITS FOR CURB RAMP SIDEWALK WIDTH 6'W X 12"D CONCRETE CURB 6' MIN 112" EXPANSION JOINT(TYP) SIDENWALK WIDTH 9 MI •cry. 8 TYP y,y "�' _ '24" TYP " \ /�• R=V (TYP) 12" MIN // �o�•. DEPRESSED (TYP) CURS &GUTTER 4ER 4' MIN. �\ DETECTABLE WARNING SURPACE(TYP) V2" EXPAN&ON DEPRESSED CONCRETE DEPTH JOINT (TYP} 2'-6° CURB 8, GUTTER (HEICHT VARIFS RAMPI FLARE 6" URBREVEAL DETERMINED LANDING 4" NOTE: ' USE SMALL FLARE ONLY WHEN A CURB BY FLARE SLOPE} WOULD DIRECTLY CONFLICT WITH APPROACHING VEHICLE TURNING MOVEMENTS. TYPE N-3 O1 8.33 % (12:1) MAX RAMP SLOPE O CROSS SLOPE: 2.00% O3 CURB RAMPS REQUIRE A (4'-0') MINIMUM LANDING WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. O RAMPS AND DOMES SHALL BE INSTALLED THE SAME WIDTH AS THE SIDEWALK. 4' MIN LANDING SI OE WALK AREA 112" EXPANSION JOINT (TYP) 112" EXPANSION 2 JOINT (TYP) 10% DETECTABLE WARNING ` "•• SURFACE (TYP) "10 tp°r V (TYP) 4'MIN. DE RESSED24' CURB 8 GUTTER 112"EXPANSION DEPRESSED 2'-6" JOINT (TYP) CURB & GUTTER HEIGHT VARIES URB REVEAL DETERMINED BY FLARE SLOPE) CONCRETE DEPTH RAMP IFLARE 6• TYPE N-3A SHEET OF LANDNG 4" (COMMERCIAL/RETAIL USE) CITY OF RALEIGH EXPANSION JOIN MA%. StoPE t!4'IFT IVY E%PAN3I°R JOIN[ 15' SIDEWALK c I °IITSER �+ vAa. �vro zS NAk .{ Tr '� SEC"IION A -A NOTES: 1, WHEN A DRIVEWAY IS TO BE CONSTRUCTED WHERE FINAL LAYER 6.THE DISTANCE FROM THE END OF A STREET CURB RADIUS TO THE OF ASPHALT HAS BEEN PLACED, THE CURB CAN BE SAW CUT IN A BEGINNING OF THE DRIVEWAY RADIUS SHOULD BE MINIMUM OF 20 FT. STRAIGHT LINE AND REMOVED. IF THE FINAL LAYER HAS NOT BEEN PLACED, 7. CURB RADIUS TO BE DISSIPATED BETWEEN LIMITS NOTED ABOVE. THE ENTIRE CURB AND GUTTER SHALL BE REMOVED AND THE DRIVEWAY 8. T MIN. BETWEEN DRIVEWAYS ON ADJACENT LOTS. SHALL BE A MONOLITHIC POUR USING 3000 PSI ,MAX. 4' SLUMP CONCRETE. 45' MIN. BETWEEN DRIVEWAYS ON SAME LOT, 2. EXPANSION MATERIAL SHALL EXTEND THE FULL DEPTH OF THE CONCRETE, 9. NO RADIUS ENCROACHMENT SHALL BE ALLOWED ACROSS AN 112' EXPANSION JOINTS ALONG SIDEWALK SHALL BE LOCATED AT NOT MORE THAN 40' ADJOINING PROP. FRONTAGE. THIS IS DETERMINED BY EXTENDING INTERVALS & DUMMY CONSTRUCTION JOINTS AT 6' INTERVALS. DUMMY A LINE FROM THE PROPERTY CORNER PERPENDICULAR TO THE RAW JOINTS SHALL BE AT LEAST 113 THE SLAB THICKNESS VN DEPTH. TO THE CURB AND GUTTER LOCATION, 3. SLOPE ON UNPAVED AREAS BETWEEN BACK OF CURB & SIDEWALK SHALL BE 14' PER FT. 10. ALL CONCRETE MOST BE POUREO ON SAME DAY AS INSPECTION O 4. NO EXPOSED AGGREGATE OR OTHER SPECIAL SURFACE TREATMENTS fN ROW. OR RE -INSPECTION IS REQUlREC. Z 5- W-DIMENSION AS SHOWN ON PLAN VIEW SHALL BE AS FOLLOWS: tmrl 10' MINIMUM, 18' MAXIMUM FOR RESIDENTIAL DRIVEWAYS 11. DRIVEWAY RADIUS SHALL BE A MINIMUM OF 5' FROM ANY CATCH BASIN, --i ro 36' MAXIMUM FOR COMMERCIAL DRIVEWAYS O 7'I N JOINT FILLER 118" RADIUS (TYP.) NOTE: MAINTAIN 50' MAX. BETWEEN EXPANSION JOINTS OR AT ALL RIGID OBJECTS. ----------- --- FRONT ELEVATION 114" TRANSVERSE EXPANSION JOINT B' 24• -� 6" 3' 4.1 4.5„ • 3" SLOPE=1rz'1Fr. SLOPE=1 rz'IF1. • ^^ °aood e$a�oo.00 oO:�a op�;>e �e oe 4• 0 °$p°°°° 1Po� ��O �o °:o'� $ 4'�"°°e°2a8�✓�&o�gi."o YSAe B°A$to:.'O:ebo.a°i°,• 1. 30" CURB & GUTTER 18, 12" 2. 30" VALLEY TYPE GUTTER ry v�rq•R. .. - 'O ` e'o ' •a eo°.oe o' •�•° ', oa e• • 00 0 0.� � ' Pa'$�� ', 1 91 k a, b°o'":911'a:>°o °�b°A`GC$o€S'GC'°c+o"2': a7 p ❑ • o� I .Q::e:�0.`;�n'ti0€i °s'L2°�eGL•3�°�Pa 4" COMPACTED A.B.C. UNDER STANDARD CURB & GUTTER (MIN! MEDIAN CURB AND GUTTER SIDE ELEVATION NO VALLEY CURB SHALL BE USED AT INTERSECTIONS, HYDRANTS, ETC. TR 3"R 6" 6• 24' "v - •' o0 8�' T� 6' •3. sJOPe•rrz•r FT. 4" �o°°°�o�c � 0'e o$UaQ,•.�.Qtr°�e 6„ .. ° 5' 12' MEDIAN CURB AND GUTTER ph�f�y�$ao 8e o°`•••° ° !J; 4" (NON -MOUNTABLE) SPELL CURB DETAIL NOTES: 1. 10' MAXIMUM BETWEEN DUMMY JOINTS. 15' MAXIMUM BETWEEN DUMMY JOINTS ON MACHINE POURS. 2. 1!2" EXPANSION JOINT EVERY 50'. .3. 3000 PSI CONCRETE MINIMUM, 4" SLUMP MAXIMUM. 4_ LIQUID MEMBRANE CURING COMPOUND SHALL MEET THE REQUIREMENTS OF SECTION 1026-2 OF NCDOT SHEET 1 OF2 STANDARDS & SPECIFICATIONS FOR ROADS AND STRUCTURES. CITY OF RALEIGH 5. ALL CONSTRUCTION JOINTS SHALL BE FILLED STANDARD DETAIL WITH JOINT FILLER AND SEALER IN ACCORDANCE WITH NCDOT ROADWAY STANDARD DETAIL B46.01 REVISIONS WTEr81111e VOTTO SCALE THE JOINT MATERIAL SHALL CONFORM TO SECTION 1028-2 OF NCDOT STANDARD & SPECIFICATIONS FOR CURB AND GUTTER ROADS AND STRUCTURES. 6. REFER TO NCDOT DETAIL 846.01 FOR CURB AND GLITTER SUPERELEVATION RATES. T-1 0.2V.1 PAY LIMITS FOR CURB RAMP , I 6"W X 12"D yr"RASSSTR/P CONCRETECU B 2 O (D12' 5' MAX. 3 D. (TVA) e ego tia,4 8 se _r CROSS SLOPE NOT TO EXCEED 2 % ON ANY R=1' (TYP) PORTION OF RAMP OR 4'n)-P� DETECTABLE 1!2^ EXPANSION TRANSITION TO STREET. 4f/N WARNIJOINT (TYP) 5URFACEI(T YP) TYPE N-4 O SLOPETO MEET GRADE, W MAXIMUM. O CROSS SLOPE. 2.00% O3 CURB RAMPS REQUIREA (4'-0") MINIMUM LANDING WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOPE OF 2..00 % WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. CONCRETE DEPTH Oa RAMPS AND DOMES SHALL BE INSTALLED THE SAME RAMP 6" LANDING 4" O WIDTH AS THE SIDEWALK. IF LENGTH EXCEEDS 5', TRUNCATED DOMES SHALL BE INSTALLED ALONG THE BACK OF THE CURB COVERING THE FULL WIDTH OF THE RAMP. 112' EXPANSION JOINT (TYP) Gpgss'sTgiP �s-1�p ' - iN��Nc�' 6"W1 X 12" p CONCRETE CURB 2 0 : • 1 ' O 1 IT D. (TYP) 5' MAX. e e 4 8 CROSS SLOPE NOT TO EXCEED 2% ON ANY PORTION OF RAMP OR R=1' (TYP) TRANSITION TO STREET. a/O DETECTABLE 112'EXPANSION 4'M/N WARNING JOINT (TYP} SURFACE (TYP) SHEET40F8 112 " EXPANSION JOINT DRIVEWAY GRADES EXISTING OR PROPOSED DRIVE WAY SIDEWALK PAVEMENT GUTTER LINE /APRON xM16°!° ". a. a-•. :. 8::"d-r. 11111_11=(I'4% 25 0 2' 6.5' 'k 5' FOR SENSITIVE AREA AVENUE AND SENSITIVE AREA RESIDENTIAL STREET A. CURB & GUTTER, SIDEWALK SECTION VARIABLE PAVEMENT WIDTH SHOULDER WIDTH V4"IFT 114" PER FT. OR -2.08% +a% -8.33°o III�II=11- . ...... ... ... ...... ...... OR Illzw 18% 1 "IFT 5' B. SHOULDER SECTION NOTES: IF THE SLOPE BETWEEN THE TOP OF CURB AND GUTTER AND A POINT 30 FEET FROM THE CURB AND GUTTER EXCEEDS 20%, THIS SLOPE SHALL BE ADJUSTED TO A MAXIMUM OF 8,33% ( 1"/FT) UP OR C175/0 (1I2" IFT ) DOWN. FACEOFCURB 10" AA BB CC 7" 30' 2,-6" 2,�6" 2%6" 2--6- PLAN VEIW 8 314 SECTION A A SECTION B-B SECTION C-C SHEET20F2 CITY OF RALEIGH STANDARD DETAIL NOTES: TRANSITION NOT TO BE LOCATED WITHIN REVISIONS DATE -alma ,vorros LE THE CURB RADIUS. CURB TRANSITION TO 2'- 6" VALLEY GUTTER T-10.26.2 PAY LIMITS FOR CURB RAMP CURB ANDGUTTER -'k 8"W X 6"D •Y. - Y • O 112" EXPANSION CONCRETEDEP- JOINT(TYP) RAMP IFAARES 6" OLANDING s 4" 5' MAX. O� f q AND GITCUURER 1(2" EXPANSION JOINT(TYP) 24"TYP. ' - SURFACE •-NON-WALK 6, T 12" MIN. (P ) X SIDEWALK 4MIN. TYPE R-1j' 6" X 12" CONCRETE CURB O 8.33%(12:1) MAX RAMP SLOPE DETECTABLE WARNING (DCROSS SLOPE 2SURFACE00% - O3 CURB RAMPS REQUIRE A (4'-0") MINIMUM LANDING 4(MIN) WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL ` SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM 1 P2" EXPANSION TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. JOINT (TYP) ` 4O RAMPS AND DOMES SHALL BE INSTALLED THE SAME \ SIDEWALK WIDTH AS THE SIDEWALK. 7-8" CURB AND GUTTER O IF LENGTH EXCEEDS 5, TRUNCATED DOMES SHALL ` \ BE INSTALLED ALONG THE BACK OF THE CURB COVERING THE FULL WIDTH OF THE RAMP. TYPE R-2 NON -WALK SURFACE (USE ONLY WHERE WATER WILL NOT " POND WITHIN LANDING) R=V (1YP) 1 O DETECTABLE \ fi"x 12"CONCRETE WARNING •04 CURB SURFACE '• ;; ) 4' MIN. 2'-6' CURB &GUTTER TYPE R-2A SIDEWALK U2' EXPANSION JOINT (TYP) 2 __ NON -WALK SURFACE .•: J ••• CONCRETE DEPTH RAMP! FLARES 6" SIDEWALK -" 112"EXPANSION LANDING 4- V- JOINT(TYP) W x 12" CONCRETE CURB SHEET 5OF8 R=1'(TYP) " DETECTABLE WARNING ` 4 CITY OF RALEIGH SURFACE STANDARD DETAIL 6 (TYP) REVISIONS OR re: NIN8 NOTTOSCAtF 4' MIN. \ 1W EXPANSION SIDEWALK TYPE R-2B JOINT (TYP) CURB RAMPS (RETROFIT) 2'-6" CURB AND GUTTER NON -WALK SURFACE T-20.01.5 ASPHALT PAVEMENT PATCH AND RCP PIPE BACKFILL SAW CUT SAW CUT ANDTACKAND TACK EXISTING PAVEMENT ! EXISTING PAVEMENT 4 /f NEW ASPHALT 3" MINIMUM �1 L �00 �oaQo130000000° Oa0 °0 D° po0o0Doo°Oa °"QOoOoo�o o/p�°p01 oOD�oO o0�°O p NEW ABC 12" MINIMUM DEPTH 004 O,0^o Do Oo0 o,o .O °0 0 o O°0°o O° EXISTING ABC T KEY -IN I�T 1' KEY -IN EXISTING ABC III -III I I I�I I ! 1. EXISTING SUBGRADE III IIII�I�I�I O 0 0 pQOD SEE NOTE #7 CA0,F800 MOaOao NOTES: 1. THE PAVEMENT EDGE SHALL BE DEFINED BY A STRAIGHT EDGE FORMED BY A MACHINED SAW CUT. 2. THE TRENCH SUBGRADE MATERIAL SHALL BE BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DENSITY OF AT LEAST 95% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL 1N ACCORDANCE WITH AASHTO T-99 AS MODIFIED BY NCDOT. 3. THE FINAL 1' OF FILL SHALL CONSIST OF ABC MATERIAL COMPACTED TO A DENSITY EQUAL TO 100% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-80 AS MODIFIED BY NCDOT. BITUMINOUS BASE OR BINDER MAY BE SUBSTITUTED IF APPROVED BY TRANSPORTATION DIRECTOR OR DESIGNEE. 4. THE ENTIRE THICKNESS/VERTICAL EDGE OF THE CUT SHALL BETACKED. 5, THE SAME DEPTH OF PAVEMENT MATERIAL WHICH EXISTS SHALL BE REINSTALLED, BUT IN NO CASE SHALL THE ASPHALT BE LESS THAN 3" THICK. 6. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY AND ROLLED WITH A SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH. LEVEL PATCH, 7. FOR RCP 36" OR LARGER, 457 OR #67 WASHED STONE SHALL BE INSTALLED TO THE SPRING LINE BEFORE BACKFILL. NOTE: SEE STANDARD DETAIL T-20.05 FOR I PAVEMENT MARKING PLACEMENT Jlj STOP BAR GRASSEDAREA SIDEWALK PED-RING S6]EWALK j STOP BAR 2 X v Q mwm 6 STOP BAR SIDEWALK SIDEWALK PEC-XING' DETAIL SHOWING TYPICAL LOCATION OF SIDEWALK ACCESS RAMPS, PEDESTRIAN s�o CROSSWALKS AND STOP BARS, R VARIABLE STOP BAR SIDEWALK PE1-XING SIDEWALK GRAS$EDAREA �- a Z ow L1 z STOPBAR i m z } STOP BAR I ow Id o GRASSED AREA SIDEWALK SIDEWALK DETAIL SHOWING TYPICAL LOCATION OF SIDEWALK ACCESS RAMPS PEDESTRIAN CROSSWALKS AND STOP BARS FOR TEE INTERSECTION. } STOP BAR SIDEWALK SIDEWALK GRASSED AREA GRASSED AREA DEPRESSED CURB &WINGS SHEET I OF 8 OR HARD RETURN AT RAMP FOR RAMPS AT ASPHALT TO ASPHALT STREET CITY OF RALEIGH TYPE DRIVEWAYS OR PRIVATE STREET TIE IN. LPAY LIMITS FOR CURB RAMP SIDEWALK SIDEWALK 1!2" EXPANSION JOINT (TYP) 6'W X 12'D CONCRETE CURB 3 0 suHFncc 5"W X 12"D CONCRETE CURB ti ' R=1' (TYP) CONCRETE DEPTH DEPRESSED 2'-6" g•(7Yp}} SIDE RAMPS 4" CURB & GUTTER 4 MIFf LANDING & OPENINGS 6" 10 EXPANSION JOINT(TYP) TYPE R-3 O1 5.33%(12:1) MAX RAMP SLOPE O CROSS SLOPE: 2.00% O3 CURB RAMPS REQUIRE A (4'-D") MINIMUM LANDING WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO GRAIN TO CURB- O RAMPS AND DOMES SHALL BE INSTALLED THE SAME WIDTH AS THE SIDEWALK. 112" EXPANSION JOINT (TYP) SEOEWALK� ^ I / r6"WX 12^D CONCRETE CURB � SIDEWALK R-v (TYP) 6'W X 12D CONCRETE CORE - DEPRESSED 2'- CURB & GUTTE DETI=CTABLE WARN SURFACE (TYP) CONCRETE DEPTH SIDE RAMPS 4" LANDING & CURB RAMPS 6" 24"TYP. _ • 12" MIN. 6'fTYP) A MIN. DEPRESSED 2'-6" CURB & GUTTER (HEIGHT VARIES, CURB REVEAL DETERMINED SHEET 6OF8 PAY LIMITS FOR CURB RAMP 1 I2" EXPANSION siyq� JOINT TYP ._ 611W X 12"D CONCRETE CURB O CONCRETE DEPTH �- O5 R=1' 2 RAMPl FLARE 6" 3 I• LANDING 4" 6'MAX ,4 T CROSS SLOPE NOT TOEXCEED ON ANY ON OF G,gA'�s PORT RAMP OR R=1' (Typ) TRANSITION TO STREET. i 8'W X 6'D TYP. %err DETECTABLE 112" EXPANSION 112' EXPANSION WARNING JOINT (TYP) JOINT (TYP) --, SURFACE (TYP) TYPE N-1 (CURB TYPE) SOX. 3 O 4e . ° r O 6.33916(12:1) MAX RAMP SLOPE CROSS SLOPE NOT TO Q GROSS SLOPE: 2.00% EXCEED_ - PORTION OFON ANY RAMP OR 24" TYP WIDTH TRANSITION TO STREET, O CURB RAMPS MINIMUM LANDING 12' MIN WIDTH DETECTABLE WARNING UM GROSS WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOP SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM Nf' SURFACE(TYP) TURNING MANEUVERS SLOPE TO GRAIN TO CURB, 112" EXPANSION O RAMPS AND DOMES SHALL BE INSTALLED THE JOINT(TYP) SAME WIDTH AS THE SIDEWALK. O5 IF LENGTH EXCEEDS 6',TRUNCATEDDOMES SHALL TYPE N-1A (FLARE TYPE) BE INSTALLED ALONG THE BACK OF THE CURB COVERING THE FULL WIDTH OF THE RAMP. NOTE: USE SMALL FLARE$ ONLY WHEN ACURB TYPE DIRECTLY CONFLICTS WITH APPROACHING VEHICULAR TURNING MOVEMENTS. SIDEWALK 112" EXPANSION JOINT {TYP) 2 TYPE N-2 (RADIUS) '' 4 . GRASS - fi"W X 12'D 4'" R=1' (TYP) CONCRETE CURB - e� DEPRESSED 2'-6" DETECTABLE WARNING CURB & GUTTER SURFACE (TYP) CONCRETE DEPTH RAMPIFLARE fi' LANDING 4" Q 11T EXPANSION 112" EXPANSION JOINT (TYP) JOINT (TYP) TYPE N-2 (TEE INTERSECTION) SIDEWALK 0 aJFP " SHEET 2 OF S 4 R=r (r P) CITY OF RALEIGH DETECTABLE WARNING SURFACE (TYP) STANDARD DETAIL REVISION'S DAM ENO A10TTOSCAI.E CURB RAMPS 6" W X 12"D CONCRETE CURB DEPRESSED 2'-6• (NEW DEVELOPMENT) CURB & GUTTER T-20.01.2 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 HERITAGE , PROPERTIES, INC LU V) z�-- U W L U con W N M V = z 00 zc�J �O< V Qom= O oCOCC J m 0 m z � z 0 (D LU U m N) I..V N to z O U �N CAR�'��'�'� 9- •! .. �� �j ..Q `SEA,- y<i ��� Or'109 iQ- 1j111111110** REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET SITE DETAILS - - - - - - - - - - - - - - -- ---- - - - - - - - -- - - - - - PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION uu E M F a a ti v 00 CD N n N c-I TYPE N-1, NAA & R-1 TYPE N-2 & N.3 TIDE N PLANTING OR OTHER NON- TOT, C �7var.v KING SUR ISNOT PROTECTEpIF pRpPpFF � rOp ewalk 5 MIN -vyOjM ly�0.r -•,• • 2`Y RAMP 5 MIN SIDE LANDING LAAE •. •. F !N 0 51$ R �P flf AFI SRCE i CROSS SLOPE NOT TO EXCEED 2%ON ANY PORTION OF RAMP OR TRANSTION TO STREET. TYPE R-1A TYPE R-2 PLANTING OR OTHER NON - WALKING SURFACE IF DROPOFF IS NOT PROTECTED TYPE -R3 .{,.• �'P�'�'G' f SIDEWALK � - r� m �` gMIN /f 8.3% 5'bii SHARED RnMP .,• • N - RAMP N 40 gu YH to 8"W % 12"O CONCRETE CURB CROSS SLOPE NOT TO PARALLEL CURB RAMP EXCEED 2% ON ANY PORTION OF RAMP OR TRANSITION TO STREET. 2' STRIP IF CUT THROUGH IS GREATER THAN 4- IN LENGTH OTHERWISE PLACE DETECTABLE ADR Mlry RAMPS OFCLLFT TMRNOUGRENTIRE SURFACE RF�UOE ALIGN CURB PARALLEL 2°k 1p'I°1I,y 00 WITHCROSSWALx O M • FOAk AMP TYPE R 4 SIDEWALK 6"WX12"DCONCRETE CURB -. - .•)R?:. '� .-: �:{'jr:• CONCRETE URH 6 u CURB RAMPS AT MEDIAN ISLANDS 6 FLARE RAMP SHEET1 OF4 - / CITY OF RALEIGH HARE DETECTABLE WARNING STANDARD DETAIL _ RED SURFACE SHALL EXTEND SHARED SHARED FULL WIDTH OF SIDEWALK REVISIONS OA TE-BSI/1B NOi TOSCALF RAMP LANDING OR RAMP DETECTABLE WARNING FLARE II I I anRE II SURFACE PLACEMENT cTo B3�IIIII--� PEEP RAMP T-20.04.1 RAMP WIDTH AREA VARIABLE 4' MINIMUM BASE DIAMETER 0 0 0® o o a o 0 o a s a o a o 0.45" R TO 0.70" R B®® B® N® 0 a® 8®® b d 0 a s o 0 o a o 0 0 0 0 0 0 o e o TOP DIAMETER OF NO J R m a m m ®e o ® m 0® m m ®o m m m m 0 0 0 ® a m m m ®o ® LESSTHAN50% TO NO MORE THAN 65% OF THE BASE DIAMETER 0 65" 1.6" TO 0.9"TO MIN. 1.4" �' 2.4" PRECAST CLASS "B" T a I CONCRETE I r • 12" '1 DETECTABLE WARNING DOMES CONCRETE PAVER 4' MtN LANDING SLOPE 12:1 MAX (6' MIN.) 114"!FT 7 DETECTABLE DEPRESSED CURB WARNING DOMES STANDARD 2'-B" 4" _ �; e•CON SEE NOTE#1 CURB&GUTTER T r .'.ACC SSrR9MPI,X •. EXPANSION JOINT 1' GROUT TO SET BLOCKS 4" CONCRETE FOUNDATION FOR WARNING DOMES TO BE WITH SAME POUR AS RAMP, FLARE$ ETC. RAMP SECTION WITH DETECTABLE WARNING PAVERS NOTES: 1. DETECTABLE WARNING DOMES SHALL COVER Z-O" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL, SIZE OF PAVER SHALL BE V X 1'. 2. THE COLOR FOR THE DETECTABLE WARNING AREA SHALL BE YELLOW FOR CONTRAST. SHEET20F4 14' MIN LANDING) SLOPE 12:1 MAX(5'A° MIN.) 2" 2'DETECTABLE DEPRESSED CURB ARNING DOME STANDARD 2'-6' •: r SEE NOTE#1 CURB &GUTTER EXISTING CONCRETE SURFACE APPLIEDIRETROFIT 4" CONCRETE SECTION "A -A" DETECTABLE WARNING SURFACE SYSTEM FOUNDATION WITH DETECTABLE WARNING PAVERSnaQcoaa y IULFscALE EXPANSION ANCHOR {q��� a• 8X °o°ob✓ ..E. 00 TILE INSTALLATION VIEW B 4X SCALE ,4PL S 1B0 5W 4510E5 bIA R9Il PL NOTE: oso oEc" NT THIS APPLICATION ONLY TO BE USED R B .as wcn 'u WHEN RETROFITTING EXISTING BARRIER FREE RAMPS �T 15ao SECTION "S" TYPICAL SECTION SHEET3 OF CITY OF RALEIGH NOTES: STANDARD DETAIL 1. DETECTABLE WARNING DOMES SHALL COVER 74' LENGTH AND FULL REVISIONS DATE-aanA WTTOSra WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. Z THE COLOR FOR THE DETECTABLE WARMING AREA SHALL BE DETECTABLE WARN ING YELLOW FOR CONTRAST. SURFACE, SURFACE APPLIED (RETROFIT ONLY) T-20.04.3 o 1N• PW. GTaI( HDLEE IS LOCATIOd15) ®®®®®®®®®®®®®®®®®®®®®®®®®®®® ®®®®®®®®®®®®®®®®®®®®®®®®®®®®® RAMP SECTION WITH DETECTABLE WARNING SURFACE CAST -IN -PLACE SYSTEM SLOPE 12:1 MAX (5'-4" MIN-) (4' MIN LANDING) 2'DETECTABLE DEPRESSED CURB WARNING DOMES STANDAR e SEE NOTE #1 CURB & G A OCESS/ MPrK EXPANSION JOINT CASTAN-PLACE DETECTABLE WARNING SURFACE SYSTEM NOTES: L DETECTABLE WARNING DOMES SHALL COVER 2'-O" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. 2. THE COLOR FOR THE DETECTABLE WARNING AREA SHALL BE YELLOW FOR CONTRAST. SPEET4 OF 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 1 HERITAGE , PROPERTIES, INC tR;N ALUMINUM EDGE RESTRAINT u" I 1 i GALVANIZED STAKE BRICK OR REFER TO -�-T- GRASSED PROPOSED SIDEWALK RECOMMENDATION FOR MANUFACTURER'S 203/gC(64 MM) MINRETE RTHICKNES5 UTILITY STRIP (3000 P.S.I.) CONCRETE PATH INSTALLATION z' I v4"rFT v4"rFr I V TO 1 112" (25 - 40 MM) 1!4"IFT ,L6, alr. I TL�Tiaul-a o COMPACTED BEDDING SAND �' /�l / \ ° a ° °o a°¢.• '*Uo.��O ••8 •.- I / 00000�o oodoan z U LU 2'-6" CURB COMPACTED TO A DENSITY PLAN VIEW SAW OUT JOINT SPACING @ 10 O.C. 1 M ru a I AND GUTTER OF NO LESS THAN 95% \o o-p as 0. ° \ a o oo\ p`p o - I rid / ji /Lr�li/ 0 Ed Cn TYPICAL SECTION CONCRETE PATH z >I (3000 P's,L) 4" (1^OOAMMEMIN. GHICKNESSco M ASE N c 7 z mI SHOULDER SHOULDER COMPACTED SOIL SUBGRADE / ^ z � ➢ Z ZI v FR z M -T I 114"1FT 1I4"!FT 114"!FT z JOINT FILLER SIDEWALK SURFACE �- nlr, SECTION 1 M , ^ J Ill �N-,'NPPE,4�L- ° •, IIIIFp E�II�IF_II w v i, F'1= IEI 7 II -I C-II III -I ^- EI E- m m 0 m 4" COMPACTED TO A DENSITY 112 OF NO LESS THAN 95% II TYPICAL SECTION CONCRETE CURB BRICK OR O�/ U SET 114" (7 MM) BELOW TOP OF PAVERS CONCRETE PAVER LL 6 AND CONTROL JOINTS @ 15' (4.58 M) OC a a O �/ O TRANSVERSE EXPANSION JOINT 2 318" (60 MM) MIN. THICKNESS = PLAN VIEW PATH SURFACE JOINT FILLER •o '° v ¢o ;•O, o ° • o °o. • °Qe e e 1" TO 1 1 /2" (25 - 40 MM) J m O 2" SF 9.5A 9 'tee o o P o 0 0 0 0= o COMPACTED BEDDING SAND z ° ' o'o I.-. - y - ¢°e •q°oo 00e� ono$ y o ab A °• i O NOTES: COMPACTED AGGREGATE BASE J O 1. TRANSVERSE EXPANSIONJOINTS TO BEA MAXIMUM OF 50 FEET, o 0 0 0 / 4" (100 MM) MIN. THICKNESS 2. ALL CONCRETE TO BE 3000 PSI AND FINISHED WITH CURING COMPOUND. c11ABr (D 3. A 6INCH DEPTH IS REQUIRED AT LOCATIONS OF DRIVEWAY CROSSINGS, V l� TRANSVERSE EXPANSION JOINT COMPACTED SOIL SUBGRADE LU CCC"' AT STREET INJTERSECTIONS (ALONG THE LENGTH OF RADIUS CURB RETURNS), AND IN THE HANDICAP RAMPS. v SECTION 2 NOTES- 1. / 1. TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF 50 FEET APART. /1/ ` v / 2. ALL CONCRETE TO BE FINISHED WITH CURING COMPOUND. Lj� to COMPACTED SUB GRADE 4. SAW JOINTSEPTH EVERY10F 4. SAW CUT JOINTS EVERY 10 FEET OR SAME AS WIDTH. WHICHEVER IS LESS. NOTES: 5. NO UTILITY SURFACE COVERS/PLATESIMANHOLES (La- WATERLINE VALVE COVERS, ETC.) SHALL BE LOCATED WITHIN PATH 1. BRICK OR CONCRETE PAVERS ALLOWED ONLY UNDER SPECIAL CON DITIONS. AND SHALL BE MINIMUM 1 FOOT FROM THE EDGE OF PATH. 2. THICKNESS OF BASE MAY VARY WITH SUBGRADEITRAFFIC CONDITIONS. 6, ALL PATHS SHALL BE LOCATED MINIMUM 6 FEET FROM THE BACK OF CURB. 3. SCATTER SAND OR SCREENINGS OVER COMPLETE WORK AND SWEEP INTO CRACKS. SHEET i OF2 7. MULTI -USE PATH WIDTH TO BE DETERMINED BY CITY OF RALEIGH BASED SMEET2OF2 4. CONCRETE PAVERS SHOULD CONFORM TO REQUIREMENTS OF ASTM C-1319. ON ROADWAY TYPE, LOCATION AND PEDESTRIAN VOLUMES. BRICK PAVERS SHOULD CONFORM TO REQUIREMENTS OF ASTM C902-95 O CITY OF RALEIGH CITY OF RALEIGH 5. SEE CITY OF RALEIGH CODE SECTION 10-7001 (0) FOR CONDITIONS UNDER CITY OF RALEIGH STANDARD DETAIL STANDARD DETAIL WHICH CONCRETE I BRICK PAVERS ARE ALLOWED. STANDARD DETAIL ( , REVISIONS DATEPi,S NOTTOSCw REVISIONS DATE&nne MOTTOSCAIE v REVISIONS DArEB�lne norra3eAL� ASPHALT MULTI -PURPOSE CONCRETE MULTI -PURPOSE CONCRETEIBRICK PAVER PATH PATH SIDEWALK DETAIL T-30.02.1 T-30.02.2 T-30.03 TREE G NEW STREET TREE (TYI EXISTING/PROPOSED 6" GRANITE CURB " ) CONCRETE PAVER: I PER CITY OF RASTER PLAN ;ORED CONCRETE (VING (TYP) PER CITY RALEIGH SPEC'S: (PITAL GRID SBF TREE GRATE D22 Series o'-s' �o �o" SCORED CONCRETE PAVING PER CITY OF RALEIGH SPECS: 'CAPITAL GRID' CONCRETE PAVING PATERN N.T.S. PROPOSED BITUMINOUS CONCRETE (FOLLOW CITY OF RALEIGH SPECIFICATIONS FOR PAVEMENT THICKNESS) FULL DEPTH SAWCUT EXISTING BITUMINOUS CONCRETE EXISTING AGGREGATE BASE COURSE CITY OF RALEIGH STANDARD GRANITE CURB 6" 1 /2" 1 /2" EXPANSION JOINT MATERIAL (TYP.) SIDEWALK 6" CLASS "A" d CONCRETE BACKING e° A° a 3,000 PSI CONCRETE DRY MIX EXISTING J SUBBASE PERFORATED POLYETHYLENE UNDERDRAIN WRAP W/ FILTER FABRIC IF REQUIRED BY GOVERNING MUNICIPALITY (TIE TO CLOSEST DOWN STREAM STORM DRAINAGE STRUCTURE) GRANITE CURB REPLACEMENT N.T.S. Or09 i�� REVISIONS N0. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET SITE DETAILS DIIIIIIIIIIIIIIII2 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'SOIL NIMUM 510L G' OP #G7 51ONt WHEN _G,� 0.rJ. Or P'PEMI=ARANC:i POCK OR WAf tK 15 ENCOUNTERED NOTE5: I, TKIENC"E5 REQUIRING SHORING AND BRACING, DIMEN510N5 511ALL BE TAFPN FROM THE IN51DE `Art OF IHE 5HOki NG AND 15KAGING. 2, NO ROCF5 OR BOULDERS 4. OR- LAKGtK 10 M USED IN BACKPiLL, 3. All BACKFII I MATFIRIAt SHAH I3E 5UITAF31F NATIVE MATERIAL, 4, DACKPl11 51IAI.I BE TAMPED IN 9" IA T`. 5. ACI IIEVE 95% COMPACTION IN E3AGNFIILL. GAIt1IArriNG VALVE • 'E r A 9 ❑ ❑ d, D ]LOA TOP VIEW 3000 F51 50DO CON CRrT r 5HALL BC USED A5 FOOTING FOP. DlUCFILC IRON FIPF. VALVE FI AhGE M.J, FITTING a -d LN 'P TAPPING 5LECV'F 51DE VIEW NOTF5: I CQNcKE7r 5HALL NQT CQNTAGT BOLT 5 OR IND5 OF MECHANICAL JOINT FITTiNG:a. 2. 5CC STANDARD RfACIION BLOCK 01Y OF FIALtIGH TABLE5. W- 10 AND W- I I FOR AREA OF OLPART MLIQ 1 OF i'I)(5L IC I T II I I IE'i CONCRETE REQUIRED. 4" - 24" STANDARD TAPPING 5LEEVE AND VALVE A55EM5LY MVG. No. KtVI510N5 pATP 1 REVI5ION5 DATE W- 14 Y.C.A_ 17-31-5JI RRH f _31 -00 D.W.C. 9-7-99 J.P.5. 1 1. 1 _1 O CAST uATT a❑L WATER IN - PLAN VIEW Manufacturer M❑/DAY/YR Class 35 Elva IOM VIEW NOTE I 'WATER" LETTERING MUST BE I " RA15ED [RECE55E4 FLUSH) 5CCT II�N VTV NOI t Z - VALVE COVtK 5HALL fat DOMt51 CALLY CA5i , NOI t 3 - COVER MU51 HAVE A MINIMUM WLIGFii 01- 25 F'OUN05. NC3TF 4 GQV1-R h405T aF GLA55 35 0K GRr&TCR. NOTI 5 CQVLR MU51 kIF-P OR. FXCF10 AA54TO H 20 LOAD KEQUIRLIArNT, 5. 0 a X f"ROPERIY MINIMUM -3 G' HONIZONIALCLEARANCE iJt FROM ANY013JECT. FIRE HYDRANT, PUMPER NOZZLE TO BE POIHTL-D 70WARD5 FIRE TRUCK ACCL55. TRAFFIC FLANGE 5ETWEIEN 2" - 6' ABOVE GRADE 91DEWALK CURB AND GUTTER PAVEMENT `r' VAI VE r30X G" GATE VALVE CONC.IHKU51 N COMPACT ED 6ACi:1­151 BLOCK [TAMPI'D IN G" I IFT5) n• _6" MIN. BRPNCII PIPE MAIN RF5TRAINING GLAND5 I'-3'x 4" 1HICK RE�01RAINING GLAND5 7 CU. FT. CRIJDHFO 5TONF MIN, UNDR.5IUR15ED tAKIH. NOTL5: I , FIRE HYDRANT SHALL BE A5 MANUFACTURED MUCLLER, AMEFUCAN DARBLINS. KCFINEDI'. MW. WATEKOUS, CLOW, EAST JORDAN IROIJ WORF5, OR U5 PIPE, 2 BRANCH PIPE 5HALL dt LAIC lILL. IRON AWWA C150 _% 3. G" CATE HALVE ;�l1ALL BE AWWA C500-CG 01 EN LEFT 4. 5TEEL RODS AND DOLT 511ALL BE + 11OT DIPPED GALVAN12ED 5. FiRL HYPRANTG WILL BC I45TALLED IN TRUE VERTICAL F051 ON P.IODS SItALL NOT E3E COUPLED MORE TIIAN ONCE. IF T LIE LENGTH F-P,OM Dit VALVE TO tHE HYDRANI Fa'CU05 20' 1 HEN A MECHAN"L RhnIRAiMiNG GLANv WII H A Ktl5AKCAGE 5HALL bt 11<)TALLED NO MORE. IIAN 10' FROM nY0FANT AND POL'P.ED IN CONCRETE. 1`1RE'1YDP.AN75 TO BE LOCATED IN ROW OR 2 FOOT EA5FMENT ADJACENT TO ROW ANY1IMF 51iF WORK, WN51RUCiION, R.OAL) IWOKK.. OK ANY 01 HEK WOKK C;HANr4rS 1 Hf GKAQI` OY I HF FIrt Cllr vF RALEIGHHYDRANT_ THE EER50N R.E5EON51E)a TOR. T11E WORK 15 Kt5PON5IERE FOR DC PART ME NIT OF PUBDG UTILITIF5, Al].11151 ING IHF FIRM Hyt) ANT 1D 51 AY WiTNIN COMELIANCt. STANDARD FIRE HYDRANT IN5TALLATION DETAIL DWG. NO. KFV15101,15 I DATE I REV1510N5 I DATF ,f 4F.SI3 4-G-v,; �.n,_ W`"i ❑HI 21113kC, GAlt1IAfPING VALVt A _ A j 4. a ❑ ❑ • v A❑❑ Q• f' a A 4• TOP VIEW 000 F51 501-0 CON CRr7E 5HALL BC USED A5 FOOTING �QP. DIJL- FILL IRON FIPT. VALVE FI ANC.E Y J. FITTING a TAPPING 5LEEVE 51DE VIEW NOTF5: I CONCKrTr5HALLNO1CQNTArT BOLTS OR IND5 OF MCCHANIGAL JOINT FITTiNG:3. 2. 5EC STANDARD RfAC`TION BLOC}, Cl I DF RALtIGH TABLES, W-1 O AND W- I I FOR AREA OF 01:FAR MLN I (X 0)(5LIC IJTII I IIE`) CONCRETE KtQUIKtD, 4" 24" STANDARD TAPPING 5LEEVE AND VALVE A55EM5LY MVG. 4,10. RtVISIOr:s pATF PFVI ,ION ; DAIL W- 14 Y.C.A. I P-3 1-51 RR11 3-31 -00 D.W.C. 9-7-99 J.P.5. I I. 1 _10 �U I YF 5 H A"t DOG110USE t 2'W X 1' b'H DOGHOU5E NOT E5 r 1 ) PEINPC) RCEMEKTT: #4 {g 6' OCEW 2) CONCRETE: 4.000 P51 t?a 28 DAYS 3) G" OF #G / 5) ONE 5HALL BE PLACED IN 501 TOM Oh VAUI I 4) METER F1 ANGE SHAH. BE PLACED 4P " BEIOW `1A1511ED GRADE i KAF!`IC RAI kD AGCtS DOOR WI SLAM LOCK CAST 1N TnP W-32r CITY OF RALEIGH DEPARTMENT OF Pi1Bi IC UTfI ITIES TYPICAL 4" WATER METER. . VAULT MITI. 5" N 2 §" NOZZLE NATIONAL ST THREAD 32" MIN. 2" " NOTES: 1. ALL PUBLIC FIRE HYDRANTS IN THE CITY OF RALEIGH AND THE MERGER TOWNS OF GARNER, ROLESVILLE, WAKE FOREST, KNIGHTDALE, WENDELL AND ZEBULON SHALL BE PAINTED CHROM YELLOW WITH HIGH REFLECTIVE ALUMINUM SILVER CAPS, BONNETS AND OPERATING NUTS. 2. ALL PRIVATE FIRE HYDRANTS SHALL BE RED. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES RALEIGH, GARNER, KNIGHTDALE, ROLESV WAKE FOREST, WENDELL & ZEBUL01 STANDARD FIRE HYDRANT WI 5" STORZ PUMPER NOZZLE UAlt VALVt tt 314' ALL THREAD S7ECL ROV ECU 1 10 LENGTH) e �D 'O 5EEW 10AND W I I FOR REACTION F31OCKiNG CONCRETE AREA. i',O° M_J. NIPPI E WiTI l / G1 AND: (MIN.y VALVt MAY rat BOLTLD DIKtCILY 10 Itt. ROD REQUIREMENT5 1 _ H 4" 2 O' 7 G^ 4 12" 4 r" 6 30" 8 3b" 8 NOI t5 1, 51ttL K005 AND 301-15 5HALL BE 314" HOT pIPPtL) GALVANIZED. P. :)fE 5TANDARD TI IRIJ 5T 131 OCK. TABI ES W- 10 AND W- I I FOR CON CPIfTF. 3. CONCRETE 51IALI NOT CONTACT DOI T5 OR END5 OF MECI IANEAI FITTIN65• 4. THI5 KID DDiNG RLQUIFWENT DOE5 NOT APPLY TO FIRE HYDRANT 5. ' Mtl t I a . � n55tM�LYI I w J + APPROPRIATE BACF FLOW r d `KtVEN I ION A55tM13LY � (ABOVt GROUND ONLY) o N +e I DOMESTIC I [HE v APPROPRIATE FIRE I INE BACKFI OW FRE_ A55EM. '- IIADOVE GROUND ONLY) A a FIRE LINE I MAIN 1 1RRIGATICN LINE OFDCIF R AFM ICAPI I MITER O REDUCED PRE-5JI A55EMBLY W A55tMr3LY (ABOVE GROUND ONLY) I _ SERVICE TAP5 FOR P" AND 5MAI I ER DOMESTIC 5FRVICE5 MAY BE BY CORPORATION COCK5. i ARGEIZ .`)ERVICE5 WI I REQUIRE A TEE AND GATE VA1 VE OR TAPPING 51 EEVE AND VALVE A35fMBLYAND 90' BENV. 2. DOMESTIC 5ERVIGE TAF'S 5HAtL BE ALLOWED ONLY ON G" OR LARDER FIRE UNIE5 BEFORE THE BACKFLOW A55LM13LY 3, ONE DOMESTIC TAP PER PI RE LINE QN 5-1 KEET 51Dt OF BACKFLOW, 4. PIKE LINE 5HALL HAVE A FIRE HYDRANT 0K BLOW OFF A55tM13LY AI 115 END 1 U FACIUTAI E PLU5HfNG WHEN NEEDED. 5. IRRIGATION METER 5HA1 I r3F LOCATED ON TI1E 51DE OF DOV IC MFTFR WfTI I INCREASING ADDRE523Fw- 6. THE BACKFLOW 5HALL 15F IN5TALLCD NO MORE THAN I C' FROM THE METER IN A V15IBLE LOCATION, r, LIONISE fCIIRk1GAl14N BACK( LOW KISERl51Al1UPIPE 5HALL BE OF CLIPPER OR BRA55. 0. T I I E RP Ul IElf VALVE 511Al. I 13E A MINIMUM OF I P" AT30VE ANY MAT FRIAI. (MUI CU INC.I UDED) OR GRADE. 9, A SFRVICF VALVE 15 REQUIREP AFTFR TI IF MFTfR BUT BFFORF THE 13ACKFLOW A55FMBLY FOR MAINTCNANCr AND REPLAGCMPNT PURF05r5. 10. THE IN5TALLATION MU5T AL-90 MITT ALL CODE REQUI RUM ITNT5 FIE KTHE NC PLUMBING CODE, 191 I G" OPERATION NUT 1 2.50V CL 2 1 /2" NATIONAL STANDARD OUTLET T11READ5 CIIY OF RALEIGH DCPART MCNIT OF PUE3UG UTILITIF5 HYDRANT OPERATING NUT AND 2 ill" OUTLET THREAD5 pWG. NO. REVI5ION5 DATE REVI51ON5 DATE - KRH 3-31-00 DHL 2 1508 A,6,13 1304 J. .5 f l-f-IU APPR❑%,[D h:1=1«❑D F❑F' D71r+510I+ DP ,ALVE ['C!' I IOTE 2: G' WNCKM rav rzowR[O ON AE; 'JAI I'141f M,r rk1 _W7IF IV>11.:I INUr �A1II1Nn'u IN ? e -A P SEE STANDARD W- 18 ° ATE 2 1.OK C;OVtR UtIAll L5. d O a a v .fL t. �• P 4r- 51ANDAKD VALVE I m TOP SECTION TO F � JE3� DOME5TI0 f BE Si DE SECTION r CA.5TING FINAI PAVEMENT COURSE I AL�'E 5OX COVER CONCRE l E PAL] VALVE Boy u5E 5' SOLI PIPE FOR E[TEN51ON5 IAMPtV ; L ACK•F 1 LL WA1EP VALVE o Q MAIN 51AE3-IN C.I, OR D.I. '•- P[Pt III TAMPED ^� : 2ACKFILL - Nr.r11'r. it Jrwc 00v W, IV WNI PC WA IOL .+urn 21 ALL TRAFFIC CAST-N❑5 MUM 6E C+Ag5 35 O1 GREd7RP, 5k FOO ANC "ALVtS OVEF 1 O CET- a 1'A:vE S:t6.1 L'YTL'N910N M1 V BE UUD10 BRING YP A DEPTH OF HD M0IIpTr1AN 5', W1 N'FON M1.61 BE A MrkIVL I, or I•:"rj11r1 �I�pF. 5 FANDAKD VALVt BOX +1 '01 wL 'RYL box wGwn I rrrlu Mto yr 65 f BID 1-1 OM 5EC f ION R. 90' DEND5 TO 3 4' 5TFEL 1=5 (TYP.) TO ff HAVE BLOCKING HOT DIPPCD GALVANIZED_ -1 F D.I. PIPE APPROFKIAI E BACKFLOW U PREVENTION u� DEVICE �o Uh _� p t'7 LP n o, 7Q 7--- y CS1 r n ❑ = [SI Q O a n�1 z 1 � � n s 6 � rn FR U�n 70 O 5 C?' ALL Bi=LL 0 ' I y0° BENU GATE VALVE BYPA.Sa TO BE ROODED TEE TO TEE FROM 5UPPLY LINE NO FLANGE ON HOU5E SHALL SF SAME 517E D 9 1 tt 519F, MIN, " OF PIPE AS 5LIPPLY LINE INSIDE METER BOX GATT VALVE GATE VAIVE, cn FLANGED COUPLING ADA?FEKIF NttUtU Et MET EKAND 1EE TO 13E IN$1ALLE0 BY CITY 1) DOMESTIC METtR5 ONLY 2) ALL FITTING5 ARF TO BE MECHANICAL J01h[T 3} BRONZE 5TRAINIP R -9 SHALL HAVE NOA-IHRGADrF) BOLT HOLL5 n 611 U.I- IEt r� Y z r3RON7F .`STRAINER "A" MEIFR OPENING 41 ME1 ER 2B" d" METER 39' 0" METER 3 J" PLAN VIEW 0.5:f Y. Rl91NG STEM OR INDICATING BUTTERFLY VALVE IMIN E ETHETAPISTOAPUBLICMAIN,A ENCL05URZ 5ERVIGE VALVE MU57 6PLCEP 12" BE1N5 TYE RIGHT OF WAY PRIOR TON ALL SIDES THE BFP. 2 POSSIBLE LOCATION5 -ARE 5110". 95�N. ! 2,, MINI 2,, MIN ALL 6D"MAX SIDES "THICK � VALVE BOx CiYP7 Q CONCRETE FAD REFER TOW 19 RODDING (iYP) p ran � ;: �.d j Cl G ao.•. e ed•. •w'4V (� ➢ O a] WATER VALVE " il'PJJ5T BLOCKING REF>•R TO W-8 7C n d WATER MAIN Q ➢ _ �7 P r 1, ALL ABOVE GROUND ENCL05UKE5 MU5T HAVE ADEQUATE DRAINAGE (TWICE THE DIAMETER GRADE. rn 70 n 2 OF THE 5UFPLY PIPE) TO DAYLIGHT ABOVE 2. REDUCED PRE55URE BACKFLOW PRE5ENTER5 MAY BE LOCATED IN A BUILDING PROVIDED C rn O O THEME ARE NO OTHER UNPROTECTED TAPS BETWEEN THE MAIN AND THE BUILDING. DRAINAGE rTI Z IN A BUILDING MUST BE TWICE THE DIAMETER OF THE 5UPFY PIPE. rn U 3. ABOVE GROUND INSULATED VAULTS MUST BE A-95E 1060 APPROVED ABOVE GROUND a �0 � O �' ENCLOSURES. SEE CROSS CONNECTION MANUAL FOR ENCLOSURE FREEZE PROTECTION AND CERTIFICATION UQUIREMSNTS. _ P° Ln 4. PE51DENTIAL LAWN IRRIGATION R.P. A55EMBLIES THAT ARE REMOVED TO PREVENT 7REEZING IN THE WINTER MONTH5 MUST BE CAPPED OFF. ALL ABOVE GROUND A55EMBLIE5, EXCEPT rn rn u" RE51DENTIAL LAWN IRRIGATION A55EMBLIE5, M05T BE PROTECTED FROM FROST. G. FOR ENCL05URF DIMEN5iON5 SEE DETAIL W-34. O 03 z:7. 5TPEL RODS AND 13OLT5 5HALL BE 3/411 HOT DIFFPD GALVANIZED. - y FTI 8, ALL A55FMBLIE5 MU5T BE ON THE CURRENT APPROVAL L15T. Crn 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE PROPERTIES, INC 1 LU Ln z� U LU LU m Q0 N M V = z 00 z ( J U Q O 0 J W 0 0LU J� J U M < N 1� /A' L z 0 U ,,��11111 CAI •..G I NS ..... S. REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET WATER DETAILS D-3 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION v u v E F a 00 00 ti 0 N ti r'4 0 NEW ASPh1AL7 SURFACE COURSE EXISTING PAVEMENT 3" MINIMUM EX15TING PAVEMENT NLW ADC 12" MIN. DEPTIT �- - EXI5TING 5U BGRADE UNDISTURBED 501E COMPACTED FILL IN G" LIFTS PIPE REFER TO 5-4 5-5 NOTES: I . IN NCDOT MAINTAINED ROADWAYS ENCROACHMENT PAVEMI NT PATCH R+=QUIKEMENT5 SHALL TAKE PRECEDENCE. 2, THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT EDGE AND CUT WITH AN APPROPRIATE 5AWCUT MACHINE. 3. THE TRENCH 5UBGRADE MATERIAL SMALL BE BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DENSITY OF AT LEAST 95% OF THAT OBTAINED 13Y COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-99 A5 MODIFIED 5Y NCDOT. 4. THE FINAL I' OF FILL 50ALL CONSIST OF ABC MATERIAL COMPACTED TO A DENSITY EQUAL TO 100% OF THAT OBTAINED- BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AA5HTO T-50 A5 MODIFIED BY NCDOT. 5, THE ENTIRE THICKNESS AND VERTICAL EDGE OF CUT SHALL BE TACKED, G_ THE SAME DEPTH OF PAVEMENT MATERIAL WHICH EXISTS SHALLBE REINSTA LL=D BUT I N NO CASE 5HALL THE ASPHALT BE LE53 THAN 3" THICK, 7. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY WITH A SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH LEVEL PATCH. 8. REFER TO CITY OF RALEIGH 5TANDARD5 FOR TRENCHES AND PIPE BEDDING (5-4 * 5-5) FOR ADDITIONAL DETAILS. 9. NO HAND PATCHING ALLOWED, 10. PAVEMENT CUTS WITHIN NCDOT POW SHALL CONFORM TO THE APPROVED ON SITE ENCROACHMENT PERMIT, 8" W/ G/5/4" BOOT e, ADJUSTED TO SOLID RING t COVER, FIN15HLD GRADE OPEN OPEN 3" OUTLET = INLET f4 DLFTH " BAFFLE 2/3 TO 3I4 OF ° TOTAL LENGTH " �2 DEPTH 4, a LENGTH NOTE5: 1. REINFORCEMENT: H-2C BRIDGE LOADING (TRAFFIC RATED) CITY OF KALEIGH 2. CONCRETE: 4000 P51 @28 DAY5 DLPARTMENT OF PUBLIC UTILITIES 3. EARTHCCI O' TO 5' MAX. 1000 GALLON GREA5L INITERCLPTOR. DWG. NO. REVISIONS DATE REVISIONS DATE c5.-40 RF:I-1 3/W0 D.H.L. G/18/08 ABB 3/ 19/04 24" C24 PRECAST BAFFLE 4" THICK 24' CL FINISHED GRADE FINAL / UNDISTURBED SOIL BACKFILL '�`/ INITIAL BACKFILL .p .. G" #G7 5TONEA +_ MINIMUM SIDE WHEN ROCK 15 0" O.D. OF PIPE G" CLEARANCE ENCOUNTERED O.D, OF PIPE I ---_MAXIMLJM SIDE CLEARANCE NOTES: 1. TRENCHES REQUIRING SHORING AND BRACING, DIMEN51ON5 SHALL BE TAKLIN FROM THE INSIDE FACE OF THE 51FORING AND BRACING. 2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL. 3, ALL BACKFILL MATERIAL 51ALL BE 5UITABLE NATIVE MATERIAL. 4. BACKFILL 5HALL BE TAMPED IN G" LIFTS IN TRAFFIC AREA5, 1 2" IN NON -TRAFFIC AFEA5, 5 ACHIEVE 80 o COM A TIO IN ON-T FIC ARLAS AND 95 COMPACTIO FFIC ARLAS % P C N N RAF , A % N N TRA G. IF IN EASEMENT 4" TOPSOIL, AND 1 2" CLEAN SELECT FILL MAY BE REQUIRED. 7- NO BOULDERS 8" IN DIAMETER OR GREATER ALLOWED IN FINAL BACKFILL CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES TRENCH BOTTOM DIMENSIONS � DACKFILLING REQUIREMENT5 FOR DUCTILE IRON DWG. NO. REVI510N5 DATE REVI510N5 DATE !W C. 9-3-99 5-4 RRH 3-30-00 COVER 120 L135_ MINIMUM I 23 112" 2 1 " 7 /2" ' BUTYL-NEK OK APPROVED SEALANT BETWEEN FRAME AND COVER NOTE57 1) ALL MANHOLE FRAMES 5HALL BE DOML5TICALLY CAST, 2) FRAME 5HALL BE A MINIMUM WEIGHT Of 182 L55. WITHIN PUBLIC ROW AND 160 L55. WITHIN. EA5EMENT5, 3) COVER SHALL WEIGH A MIN. Of 120 LB5. 4) ALL MANHOLE FRAMES DIJT5IDE OF PAVED 5LfrFACE5 5HALL BE HOLTED TO THE CONE 'SECTION OR KING WITH A MINIMUM OF 4 BOLT5 FEK FRAME, MANHOLE FRAME AND COVER HOLE I 33 1 /4" 5WX3" LAGEHiELD IN HOLE DRILLED INTO CONE OR RING WITH ANCHOR SUNK TO DESIGN DEPTH, AND 3/8`0" HOT DIPPED GALVANIZED LAG BOLT AND WA5HER- T'KECA5T BAFFLE 4" THICK I8" W/ G)5/4" _ BOOT 8" 24" 24" 24" T I II II � II II 1 ADJUSTED TO 50111E RING C COVER, FINISHED GRADE OPEN OPEN 3° INLET - = OUTLET Y4 DEPTH ' ,e �4, �4,� V3 L Y3 L Y3 L a ;, LENGTH NOTE5- 1 , REINFORCEMENT: H-20 BRIDGE CITY OF KALEIGH LOADING (TRAFFIC RATED) DEPARTMENT OF PUBLIC UTILITIES 2, CONCRETE: 4000 P51 @26 DAY5 1 000 GALLON O[L-WATER-SAND 5ET ARATOR DWG, NO REVI510N5 DATE REVISIONS DATE 5-40a RK1 3/9/O D.H.L. G/18/08 ABB NEW MANH0L15 U5L A BUTYL 5EALANT BETWEEN FRAME AND 5EE C.D.R. STANDARD MANHOLE TOP SECTION WHEN SECURING FRAME TO MANHOLE TO 5-25 FOR MANHOLE ROVIDE A WATERTIGHT SEAL. FRAME AND COVER 'o . b• . 0" . 0 24" MAX/'y ..-A �. a . •0. ECCENTRIC M.H. CONE MAY BL USED ON 8" , 1 0" ° n a AND f 2" SEWER MAIN5. c;•� MANHOLE CONE AND BARREL SECTIONS SHALL " BE A5 PER A5TM 5TANDARD5 4'-6' DIA. A5 s'.: o "Q REQUIRED m "0" RING SEAL n j bb ,•s OR RAM -NECK 1 4" m, l SHELF I , -'p is ,a �RU' SLOPE a a ; . p 'a 60, .a o d • a ' ,. y' a: b s, A L •...• ....•. - �•.••.. *0 A•• 800T LATERAL INVERT SHALL NOT BL -LOWER THAN MAIN 5791NG- LINE. MANHOLE 5HALL BE 2' ABOVE 100 YEAR FLOOD PLAIN OR SEALED AND VENT TO BE 2' ABOVE 100 YEAR FLOOD PLAIN, WHEN MANHOLE TOPS ARE IN EX'CL55 OF 3' ABOVL GRADE. OUTSIDE STEPS MUST 13LPROVIDLD. 5EE STANDARD 5-25 FOR STEP DETAIL. IN NON TRAFFIC AKEA5, TOP OF FRAME AND COVER 5HALL BE RAM V A INSTALLED A MIN. OF I' ABOVE FINISHED GROUND SURFACE, SEE SEWER DESIGN SECTION \ MIN. 9" COMPACTED #G7 STONE BASE TO BE INSTALLED UNDER NEW MAN HOLL, T_ 4 C PLAN SLIP KL515TANT CLEATS 0 Q 1 2" #3 OR #4 REBAK CORR051ON RESISTANT MATERIAL RUBBEF. PLA5TIC 5ECTION A - A LOCALLY AVAILABLI= SIZES INTERCEPTORS CAPACITY (GAL.) 5EPAKATOR5 CAPACITY (GAL.) 300 1000 550 1200 750 1600 000 20C 500 2000 2500 3000 4000 500E 0000 8000 NOTES: I . UAFFLE WALL LOCATED AT A D15TANCE FROM INLET WALL 23 TO 3/4 OF THETOTAL LENGTH OF THE INTERCEPTOR OK 5EPARATOR AS SHOWN ON DETAIL 540 BAFFLE WALL5 LOCATED AT A D15TANCE APPROXIMATELY OF Y3 OF THE TOTAL LENGTH OF THE 5FPARATOR AS SHOWN ON DETAIL 5-40.01 . 2, EACH INTERCEFTOR OR5FPARATpR5HALL HAVE INLET AND OUTLET TEE5, THE OUTLET Tff 5HALL EXTEND 50% INTO THE LIQUID DEPTH. THE INLET THE 5HALL EXTEND 25% INTO THE LIQUID DEPTH, INLET AND OUTLET TFF5 MU5T BE OPEN TO ALLOW THE COLLECTION OF F_O,C_ SAMPLE. 3. ACF55 OPENING5 OVER FAGH COMPARTMENT WITHIN THE INTERCEPTOR OR 5EPARATOR SHALL BE 24 INCHE5 iN DIAMETER AND CONTAIN PICK HOLES. ALL COVER5 SHALL SE CONSTRUCTED OF CAST IRON OR EOUIVALENT TKAFFIC BEARING MATERIAL MANHOLE COVERS MUST EXTEND TO FIN15H GRADE AND BE INSTALLED TO EXCLUDE THE ENTRANCE OF 5TORMWATEK INTO THE INTERCEPTOR OR 5EFARATOR. 4. FULL 512E DUAL 5WEEP CLEANOUT5 SHALL BE IN5TALLED ON THE INLET AND OUTLET SIDES OF THE INTERCEPTOR OR SEPARATOR. 5 INTERCEPTOP5 AND 5EPAPATOR5 MUST BE VENTED IN ACCORDANCE WITH THE NG 5TATE PLUM81 NG CODE. C. CONCRETE: 4000 P51 @ 26 DAYS. 7, 4ESIGN: AG 3 18 BUILDING CODE A5TM C1613-OG FOR GREASE INTEKCEFTOK5 A5TM C91 3-02 FOR WATER AND WASTEWATER STRUCTURES ASTM C890-OG FOR MINIMAL STRUCTURAL DESIGN LOADING 8, INTERCEPTORS AND SEPARATORS SHALL BE DE5IGNE❑ TO WITH5TAND AN H-20 WHEEL LOAD 9. INTERCEPTORS OK5EPAKATOPS MADE OF POLYETHYLENE OR FIDLKGLA55 5HALL INCLUDE A MINIMUM 12,000 Psi TENSILE STRENGTH, h 9.000 PS! FLEXURAL STRENGTH. AND 600.000 P51 FEXUKAL MODULU5, 10. ALL INTERGEFTORS AND SEPAPATORS 5HALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. PLASTIC GREEN MANHOLE MARKER -LABELED SEWER MANHOLE, SEE NOTE 3 TEST STATION OR TEST 70RT- 57ANDARp H2O7P.AFFIC LOAD RATED VALVE SOX WITH LID LASELED'TS" AND PAINTED GREEN, PLACED ABOVE LOOT' 3 FT (MIN) DOWN5TKEAM SEWER N OF WIRE INTO TEST STATION'`` I STANDARD INDUSTRIAL CRIMP I I \ \\\\\ (SIMILAR METAU. _ I 0 NO. 12 GAUGE I I I ���\ FILLED WITH z SOLID BARE CONCRETE COPPER TRACER W RE, Ty" �i i I sEwER 1 I a WRAP TRACER I LATERAL WIRE AROUND I I I I SEE CIRCUMFERENCE OF I I I I NOTE 2 MANHOLE AND SPLICE I I I 5EWER TO TRACER WIRE FOR I I I I SADDLE DOWN5TREAM SEWER I I I I TAP MAIN I I I PLOW I I I I I(- - -II % I I I I u U ------L---------�-L-��---- -V L------------------ SEWER NOTES: MAIN I . THE TRACER WIRE SHALL BE CONTINUOUS TO THE GREATEST EXTENT P0551BLE. FOR GRAVITY MAIN D O LATERAL INSTALLATIONS LE55 TH 8 FT TRACING RE SHALL ATTACHED TO THE AN R LA RALAN .THE IN WI A E PIPE. TRACER WIRE 5HALL BE LAID FLAT AND 5ECUKELY AFFIXED TO THE PIPE AT 10 FOOT INTERVALS. FOR GRAVITY MAIN AND OR LATERAL IN5TALLATION DEEPER THAN 8 FT, THE TRACING WIRE SHALL BE 5 ALLED 7 EPTH O -8 THE WIRE 5HALL BF P OTFCTED FROM DAMAGE DU G THE N 7 A A p F 7 FT A L R FR pAMA RIN H EXECUTION OF THE WORK. NO BREAKS OF CUTS IN THE TRACER WIRE 5HALL BE PERMITTED. 2. WHERE LATERAL TAPS ARE MADE BY 5EKVICF SADDLES, THE TRACER WIRE 5HALL NOT BE ALLOWED TO TO BI= PLACED BETWEEN THE SADDLE AND MAIN, 3. MANHOLE MARKERS SHALL BE PLACED ADJACENT TO MANHOLES AT THE DISCRETION OF OWNER OR OWNER'S REPF.E5ENTATIVF. N01 E5: I THE TRACER WIRE 5HALL BE CONTINUOUS TO THE GREATEST EXTENT P055i6LE. WHERE JOINTS ARE NFCF551TATED IN THE WIRE, THE JOINTS 5HALL HE SECURELY DXTENO TRACER WIRE BONDED TOGETHER WITH AN APRROVFD INDUSTRIAL CRIMP CONNEGTORTO TO JUST BELOW PROVIDE ELECTRICAL CONTINUITY. CRIMPS SMALL BE SIMILAR METAL. CLEAN OUT PLUG 2 THE CLEANOUT AT THC RIGHT OF WAY ANp OR EASEMENT 5HALL SERVE A5 THE TE57 PORT WITH THE TRACING WIRE BROUGHT UP OUTSIDE THE CLEANOUT A55DMBLY AND WRAPPED AROUND THE STACK TWICE AT A DEPTH OF APPROXIMATELY 1211 BELOW GAAUE. 3. 5PUCED CONNECIDN5 5HALL 6E ALLOWE❑ BETWEEN THE MAIN LINETRACER WIRE AND THE LATERAL TRACER WIRE, FIN15HED 4. FOR NEW 5EWER TAP5 ON EXISTING MAIN5 VOID OF ANY TRACER WIRE, PROVIDE AN o.'. GRADE ANODE FOR THE TRACING WIRE TERMINATION AT THE POINT OF THE NEW TAP ON THE !'. ` EXISTING SEWER MAIN. PAVEMENT CURB y ' p .�' O o .. o� •� � LOCI' TRACER WIRE CAST IRON OR BRONZE -CLEAN OUT PLUG z TWICE AROUND CLEANOUT a CLEANOUT A55EMBLY A552M31Y TRACER WIRE -NO. 12 9 ➢ D z 7' GAUGE SOLID COPPER z � BARE WIRE C) o 0 MAIN TRACER WIRE �� 70 rn FOR NEW MAIN (S) c1 _ 7d EXISTING LATERAL MAIN NEW 5CRVICC ON EX15TING MAIN- r�irn PROVIDE MAGNESIUM ANCDE (1 LB MIN) REQUIRED WHORE NO TRACER WIRE 15 INS7AUFI) ON SEINER MAIN COO mzz,u�� z °L 14a-cc) 00 <=w- z w S ,n � z v �-<O 0 ¢ O C7 la\u Ozzw� C_ " Q m U :7 °� O II����� �OUnu�'1�Zr�� j '•w IL U O w I 1�'-�0 Uz ro o k--D D ¢ 3NH Q 14 n __ z III....,.. w Lo L - � > z�w� uT�� �0-9 In b. U O>pO ¢�-z 4¢ ' v .a': "IR o pv� zz0r CID O w OC ��z-� ��� to B_ 7! < - ¢Tv � f ¢ W J~ Q Q O 55 - o �n �' 4'- 4 '¢ 0 - z n O z n J u, =]fix u Q p z zaz<pa� w- pu�m m ���� U s(nnO IL Ju Q T) tT1 N _ -. C] w U(n uO Zjz p .- 4 Q U = > O uj LA u) Q 11 ~ U ¢ 0O ¢ q o 0 a', a O o? - ¢ z z D aJ a� U} °LO g ZIn uu� Ow OU <UU1 u.3 ¢ 1 z0 Q� O O z ¢ z j CITY OF RALEIGH Ov = a¢_ DEPARTMENT OF PUBLIC UTILITIES 2 w TYPICAL 5ANITAPY 5EWER > 4 g LATERAL CONNECTION al n p DWG. NO. REVISION5 DATE REVISION5 DATE u Y,C.A. G-92 A.B.B. 4-8-04 5-30 KRH 3-30-00 D.H.L, G-18-08 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, INC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 ERITAGE x PROPERTIES, INC 1 ,,W 11 (V V z� U w - W m N M V = z 00 z � J �:O� VQCC- O �ol� = m z � z O J (D LU U M < r� V / z O U uuu �. \A CAI �CINE. ` . S. SLP.•`�� REVISIONS N0. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET SANITARY SEWER DETAILS D-4 W a X PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION (2)DROPHANDI 7-77 7r9" 3+a• (22mmj 19mm) 1 314' (44 J 151r8' 1114' (384mm) (32mT) TOP OF CURB NOTES: 1. THE SLOPE OF THE GUTTER TO THE CATCH BASIN ON THE UPHILL 12 3f4. 3000 P.SI, CONG. FOR SLOPE RED.'S SEE NOTE 1. T 6" �'• ', FLOW LINE 0 2-2- G 1- PIPE OR WC PIPE E' MIN..OVER 12' DEEP 12' MIN. UP TO 6' FROM TOP OF CURE. 0 e � a a ° " c 1I2' O a 112• D S1DE SHALL BEGIN 10' FROM THE THE CATCH BASIN. THE SLOPE OF THE GUTTER TO THE CATCH BASIN ON THE DOWNHILL SIDE, SHALL BEGIN 10' FROM THE CATCH BASIN. 2. STEPS SHALL BE INSTALLED IN ALL CATCH BASINS OVER 3' IN DEPTH. DEPTH SHALL BE MEASURED FROM THE TOP OF CURB TO THE INVERT OF THE CATCH BASIN. 3. SOLID CONCRETE BRICKS MAY BE USED IN 4X4X8 OR 4X8X16 SIZES. 4. NCDOT APPROVED PRECAST CONCRETE BOXES ACCEPTABLE USING STANDARD 5' CASTINGS. 5. DOMESTIC CASTING REQUIRED WITHN STREET RIGHT OF WAY, 6. 1" MAXIMUM EXTENSION OF PIPE INTO THE STORM BOX. , 6" UP TO 12' DEEP ° . �• ° ^' , ° a .{ tl V - 12- OVER 12- DEEP 6"0 0 6.4. ° I7 STANDARD C.B. STEP 3-43 REBARS� 8'LONG 1 9 T GROUT .e_ �" 6• �IN PLACE °Ne zI v4• 4. IJ 000 000 212 PIPES2z 2'1 u2• A 510E LONG ON A a• PLAN ELEVATION BLOPE-18"BELfWJ TOP OF C.B. <• SUPRE&STANYGILFA- ­SAR 8"MiNIMLIM. 8" RE516TANT OVER 12' DEEP MATERIAL 12' MMIMUM llP TO RueRER1 6FROM TOP OF CURS. 12' P,ASTIC ,sue- ELEVATION SECTION A -A IF STRDCTDRE IS GREATER TMN 12'- OEEP,FOOTING IS TD EMEND fi" U-YONOTHESTRUCTURE ° CITY OF RALEIGH s^ s" STANDARD DETAIL REVISIONS OATE.-81Iffs Mor T°scaLE 3000 PSI CONCRETE n nu rnrru �� - a wa ►Sa. 3aa� �a�aoaa�aaa�o' CITY OF RALEIGH NODUMPINGI NO TIRE RASURA- (RAISED) 35D3N OIU U3 Ia33D3N IV 53NAH0 .061hW4 015NIVHO IVkIOSV931,1110N IONId WrlO ON AD131V8 HO AiIO COVER SECTION 718" (2)DROPHANDI 3!A' (22mm? 119mmJ 1 3r4" 15 1!8• 11/4" (384mm) (32mm, (44 ) NO.3 REBAR 3" O.C. PLACED 3'FROM GROUT FRAME EDGE, ALL SIDES. TO SLAB TOP 3'f" NOTES 1. FOR 24" PIPE & LARGER USE IIII`IIII`lIII� slid IIII�IIII�II PIPE DIAMETER PLUS I2"FOR °•tl 0lllll~I° MINIMUM INSIDE DIMENSION. ADJUST TO TOP 9 CL4 "A" CONCRETE .N" OF BRICK 2. USE 4"X4"XB"OR 4"X8"X16" = SOLID CONCRETE BLOCK, CAST 2 IN PLACE OR PRECAST CONCRETE 1l2" PLASTER 2' MIN. _ TO MEET NCD07 STANDARDS 3' MAX. ACCEPTABLE. 3' MINIMUM, OVER 8' DEEP 12" MINIMUM UP TO 6' a 3. FOR STEP REQUIREMENTS, FROM TOP OF CURB rc q SEE NOTE 4 ON STANDARD DETAIL SW-10.03. N 3000 P51 CDNCRETE CONCRETE SLAB TOP 4 3_6" CLASS"A"CONCRETE III III II '0= II II III II III I I I I € I m I I NO.3 REBAR T O.C. PLACED 3"FROM EDGE, ALL SIDES. - vGi Inv I CITY OF RALEIGI STANDARD DETAIL REVISIONS OA7E:W„1e as � �aa����paaapa�ae�a• CITY OF RALEIGH NODUMPINGI NO TIRE HASURAI DI TO ONVIIIIIM DREN SAL 01 31 V2" 31 112' 31 112' (AM-) 000-)USE EAST (0oemm) 3!4" 1 TV 3' USE EAST JORDAN (44mm) IRON WORKS, C a4mmJ p3mm) IRON WORKS, INC. V-4096-2 V-4096-2 OR APPROVED EQUAL 3l4-TI IT l4, OR APPROVED EQUAL 314.1 IT (19mm) 1 114" {19mm1 (19mmj [32mm) �(251­) 2 1f2• (25mm) (25mm) (64mm) ASSEMBLY SECTION � x an! dU1ow ° MOIDAYNR X' DI Q (3) 7M"-9x3 3I4" LG HEX HD $ BOLTS, NUTS (GRADE 6) ,n WITH LOCK WASHERS ti 0 m u v ,_ M F- a m 0 ti '7 00 CD 0 N n �i N c-I BACK SIDE OF ASSEMBLY NOTE: USE GRADE 8 BOLTS ONLY FOR BOLTING TOGETHER 4 i 3' (73mm) (RAISED) 3sn3N OIU a3Ala39D3N lV 63 � N3aO r 01 SNIVHa IVNnSV93'dL10N 1DNld W000N HOSIV8 dO A JO COVER SECTION 1 114" 43zmm1 2 1q' 64mm) ASSEMBLY SECTION 31 t!2" (eDOmm) TT� 314, (lsmm) 1, (25mm) i, ID o xa.VAVUIoIv MOfOAYNR X' g DI (3) 718"-9x3 314^ LG HEX HID BOLTS, NUTS (GRADE 8) WITH LOCK WASHERS BACK SIDE OF ASSEMBLY NOTE: USE GRADE 8 80LTS ONLY FOR BOLTING TOGETHER TYPICAL MH FOR STORM SEWER PIPE SIZE MH DIAMETER 12-24" 4'-0" 30-42" 51�01 48' 54" 5'-3" - - - - - - - - - - 1 - - - - - - 1 3" SIDE ELEVATION B STANDARD MANHOLE A 1" 1„ TREAD SURFACE 1„ RING AND COVER A A 34" HOLES FOR HANDLES 15" -SEE DETAIL- r-U" 77 PLAN OF COVER B W 12" 0 4. a 4A" OR 5' 0" O T Kg T 1• � SLOPE 45' C OR 5'-0" 314^ a C C G'THICK UP TO 12' DEEP 2'-4112" i"h 2'-4112" �1'`- I-� 1 10 12'THICX OVER 12' DEEP g-3" LOPE fi'f12" - �� 6 s" F� SECTION A -A 21114' I 3000 PSI " .B 3000 P51 CONCRETE A 3„ 5"�1r2'I-�5�7if2�-I GROUT �-�SECTION A -A SECTION B-B 5" 7r=;;�I- 1 v4" SECTION B-B T TOP VIEW NOTES. } 5J0" uoulvo I 1. DEPTH MEASURED FROM TOP OF t 112" - - 12 10 1 1(4" CASTING TO INVERT OF MANHOLE, 3 V4" see R s = T 314" 2. PRECAST MANHOLE COMPONENTS SHALL T 1f2"SD. 1 MEET ASTM-C-478 REQUIREMENTS. _ HE, NUT 1 V2 3. SEE STANDARD. SW-10. 10 FOR MANHOLE S.E 314^ 41(2" COVER DETAIL. DETAIL OF HANDLE 4. DOMESTIC CASTINGS REQUIRED 21 IA'.� WITHIN STREET RIGHT-OF-WAY. TYPE A SECTION C-C 5/8" 0 t - M DETAIL OF pbl PLATES 10 OSTAINLESS STEEL DROP HANDLES NOTES: PAINT WITH RUST INHIBITING BLACK PAINT. BILL OF MATERIAL MATERIAL LIST FOR ONE UNIT - MAKE UNITS 1 C1.5 X 33.W CHANNEL 62 1/2" MK-cal 4 118" X 1' H.R. FLAT BAR 3" MK-pal 2 31W X 3" H.R. FLAT BAR 10" MK-pb1 2 112" STAINLESS STEEL ROUND ROD 18" 8 112' STAINLESS STEEL HEX NUTS 4 17T STAINLESS STEEL FLAT WASHERS 1l4j SHEETI OF2 12, 314' ss.4" CITY OF RALEIGH STANDARD DETAIL REVISIONS GATE.-61vre u TTOSCALF CATCH BASIN END ELEVATION CASTINGS 0 PERM I T G� 231l2' 21" O ( Lv ° SPACE p0 �0 �N 2 &4" ° COVER 120 LEIS. MINIMUM 25 1116" BUTYL-NEK OR APPROVED SEALANT 71/2' � 22" .� BETWEEN FRAME AND COVER 2 r Y� zs lsns° 33 114" 518"X3" LAGSHIELD IN HOLE DRILLED INTO CONE OR RING WITH ANCHOR SUNK TO NOTES: DESIGN DEPTH, AND 51B"X3" 1. ALL MANHOLE FRAMES SHALL BE DOMESTICALLY CAST, HOT DIPPED GALVANIZED LAG BOLT AND WASHER. 2. FRAME SHALL BE A MINIMUM WEIGHT OF 1132 LBS_ WITHIN PUBLIC ROW AND 160 LBS. WITHIN EASEMENTS. 3. COVER SHALL WEIGH A MINIMUM OF 120 LBS. 4. ALL MANHOLE FRAMES OUTSIDE OF PAVED SURFACE SHALL BE BOLTED TO THE CONE SECTION OR RING WITH A MINIMUM OF 4 BOLTS PER FRAME. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 HERITAGE , y PROPERTIES, INC III- 1 U , V ) zIIII- U LU - LU r�o v1J I '^ v l N M V = z 00 zc�J �OU V Q O Or- oCC = J m 0 m z � z OJcD LU U m N) I..V N to z O U ,,,,, 11111111/II"�I % �N CAR,),o ••Q SEA,- y<i 0r1,1909 0-7 '�/nllll•�`` REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET STORM DRAINAGE DETAILS D�5 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION NYLOPLAST 12" DRAIN BASIN: 2812AG X (1, 2) INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. MINIMUM PIPE BURIAL DEPTH PER PIPE (3} VARIABLE INVERT HEIGHTS MANUFACTURER RECOMMENDATION AVAILABLE (ACCORDING TO (MIN. MANUFACTURING PLANSITAKE OFF) REO. SAME AS MIN. SUMP) WATERTIGHTJOINT _ (CORRUGATED HDPE SHOWN) (4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4'- 12' FOR CORRUGATED HDPE (ADS N-121HANCOR DUAL WALL, ADSIHANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX'. SDR 35), PVC DWV (EX: SCH 40), PVC C9001C9M, CORRUGATED & RIBBED PVC THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321, BEDDING & BACKFILL FOR SURFACE DRAJNAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. 1 - GRAT£SISOLID COVER SHALL BE DUCTILE IRON PER ASTM A526 GRADE 70-50.05, WITH THE EXCEPTION OF THE BRONZE GRATE. 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A636 GRADE70M0-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS, RISERS ARE NEEDED FOR BASINS OVER 84' DJE TO SHIPPING RESTRICTIONS, SEE DRAWING NO 7001-11R065 4 • DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM 03212 FOR CORRUGATED HOPE (ADS N-12 RANCOR DUAL WALL). N-12 HP, &FNC SEWER. 5 -ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0' TD 360'. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO.7001-110.01Z 12' COVER FRAME 12' SOLID COVER 114-20 X 134" LONG HEX BOLT ZINC -PLATED STEEL NOTE: LOCATION OF LOCKING DEVICE MAY VARY voo DRILL 0.281 THRU GRATE ONLY COUNTERBORE 0.75 X .16 DP 15) ADAPTER ANGLES 'ARIABLE0'- & ACCORDING TO PLANS fil020iffetTeil 18" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY, ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION. (3) VARIABLE SUMP DEPTH ACCORDING TO PLANS (6' MIN. BASED ON MANUFACTURING REQ.) 4" MIN GRATEOPTIONS LOADRATING PART 40 DRAWING# PEDESTRIAN MEETS H-10 1299CGP 7001-110-202 STANDAPZ MEETS H•20 12B9CGS 7C01-110-203 SOLE COVER MEETS H-20 1299CGC 7001-110.204 PEDESTRIAN BRONZE NVA 1299CGPB 7001-110-205 DOME NIA 12B000D 7001-110-2W DROP IN GRATE LIGHT DUTY 120161 7001-1111021 DRILL 0 TAP 114-20 THREAD NYLOPLAST WATER TIGHT SWAGE JOINT O i i &�5 O1 25,25 Q1 . O- SEE DRAWING NO. 7001-110-364 FOR ADSIHANCOR THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY JJC MATERIAL 3130 VERONA AVE N-12 HP BELL INFORMATION NYLDPLAST HAS PROPRIETARY RIGHTS_ THE RECEIPT BUFORO GA 30518 O2 - SEE DRAWING NO. 7003-11D-031 FOR WATER TIGHT OR POSSESSION OF THIS PRINTDOES NOT CONFER. DATE 8-6-09 PVC �T PHN (770) 932-2443 SWAGE JOINT DETAIL TRANSFER, OR LICENSE THE USE OF THE DESIGN OR N 4o aSt FAX 1770) 3sWsc am 3 - DIMENSIONS ARE FOR REFERENCE ONLY TECHNICAL INFORMATION SHOWN HEREIN APPO BY JJC PROJECT NO NAME 5 ACTUAL DIMENSIONS MAY VARY REPRODUCTION OF THIS PRINT OR ANY INFORMATION TITLE CONTAINED HEREIN, OR MANUFACTURE OF ANY DATE B.609 72 X 12 ADSIHANCOR N•12 HPTEE 4 - DIMENSIONS ARE IN INCH ES ARTICLE HEREFROM, FOR THE DISCLOSURETO OTHERS 15 FORBIDDEN. EXCEPT BY SPEGIFIG WRITTEN PERMISSION FROM NYLOPLAST. �mppxnausr DWG SIZE A SCALE 1:6 SHEET 1 OF 1 DWG NO. 1285AGHP REV A Section 2722 Engineered Surface Drainage Products GENERAL PVC surface drainage inlets shall be of the inline drain type as indicated on the contract drawing and referenced within the contract specifications. The ductile iron grates for each of these fittings are to be considered an integral part of the surface drainage inlet and shall be furnished by the same manufacturer. The surface drainage inlets shall be as manufactured by Nyloplast a division of Advanced Drainage Systems, Inc., or prior approved equal. MATERIALS The inline drain required for this contract shall be manufactured from PVC pipe stock, utilizing a thermo-molding process to reform the pipe stock to the furnished configuration. The drainage pipe connection stubs shall be manufactured from PVC pipe stock and formed to provide a watertight connection with the specified pipe system. This joint tightness shall conform to ASTM D3212 for joints for drain and sewer plastic pipe using flexible elastomeric seals. The flexible elastomeric seals shall conform to ASTM F477. The pipe bell spigot shall be joined to the inline drain body by use of a swage mechanical joint. The raw material used to manufacture the pipe stock that is used to manufacture the inline drain body and pipe stubs of the surface drainage inlets shall conform to ASTM D1784 cell class 12454. The grates furnished for a9 surface drainage inlets shall be ductile iron grates for sizes 8", 10", 12", 15", 113", 24' and 30" Shall be made specifically for each fitting so as to provide a round bottom flange that closely matches the diameter of the surface drainage inlet. Grates for inline drains shall be capable of supporting H-20 wheel loading for traffic areas or H-10 loading for pedestrian areas. 12" and 15' square grates will be hinged to the frame using pins. Metal used in the manufacture of the castings shall conform to ASTM A536 grade 70-50-05 for ductile iron. Grates shall be provided painted black. INSTALLATION The specified PVC surface drainage inlet shall be installed using conventional flexible pipe backfill materials and procedures. The backfill material shall be crushed stone or other granular material meeting the requirements of class 1, class 2, or class 3 material as defined in ASTM D2321. Bedding and backfill for surface drainage inlets shall be well placed and compacted uniformly in accordance with ASTM D2321. The drain basin body will be cut at the time of the final grade. No brick, stone or concrete block will be required to set the grate to the final grade height. For H-20 load rated installations, a concrete ring will be poured under and around the grate and frame. The concrete slab must be designed taking into consideration local sail conditions, traffic loading, and other applicable design factors. For other installation considerations such as migration of fines, ground water, and soft foundations refer to ASTM D2321 guidelines. D 09 0A INVERT ALL DIMENSIONS ARE IN INCHES THIS PRINT DISCLOSES SUBJECT MATTER IN WH9CIF DRAWN BY JJC MATERIAL 3131 VERONA AVE NIYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT BUFORD, GA 30518 OR POSSESSION OF THIS PRIM DOES NOT CONFER, DATE TRANSFER, OR LICENSE THE USE OF THE DESIGN OR 816-09 PVC Nyto � ast PHN 1170) 932-2443 FAX 1770) 532.2490 TECHNICAL INFORMATION O N HEREIN SH W H Apcp BY JJC PROJECT NO (NAME r>' wwW.n I Va51-Us.Gam Y °7' REPRODUCTION DF THIS PRINT OR ANY INFORMATION TITLE CONTAINED HEREIN, OR MANUFACTURE OF ANY DATE 8.6-09 121N-30TNADSINANCORM-12HP ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS UNIVERSAL BELL INFORMATION IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST- a:imr xvintvs OWG SIZE A SCALE NTS SHEET 1 GF 1 DWG NO. 7001-110.364 REV A 12' GRATE FRAME 12' STANDARD GRATE 114-20 X 1 3I4" LONG HEX BOLT ZINC -PLATED STEEL liPLIT 196211 NOTF: LOCATION OF LOCKING DEVICE MAY VARY DRILL 0,281 THRU GRATE ONLY COUNTERBORE 0.75 X.18 DP SIZE HAMIN flA MAX 0B MIN 0B MAX C MIr�! C MAX D AVG 72" 15.338 15.549 15.044 16.294 5.50D 7.399 13.641 75" 18.230 16.470 18.975 19225 6.400 9.409 16.542 1 B" 21.929 22.199 23.527 23.822 9.459 11.959 20.773 24" 28.993 29.269 30.861 31.185 13.063 14.813 27.754 30" 37.134 37.334 39.324 39.624 14.264 1 fi.260. 35,168 ORIL! TAP 114-2C THREAD 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE:410. 769. 6139 HE s- ., PROPERTIES, INC IIII- IIIICC LU - r� V z ��.� �N CARS,, ••Q SEA,_ y<i 0r11,09 i0-7� REVISIONS N0. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-D1 CHECKED BY CHT DRAWN BY CHT SCALE N.T.S. DATE 12. 15. 2018 SHEET STORM DRAINAGE DETAILS PRELIMINARY DRAWING -NOT RELEASED FOR CONSTRUCTION D-6 E 4 SMRMWATER DETENTION SYSTEM PLAN VIEW N.T.S. STORMFILTER DESIGN NOTES STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (7). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 7 CARTRIDGES. 072" MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.5 CFS. IF THE SITE CONDITIONS EXCEED 1.5 CFS AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 2.3' 1.8, SPECIFIC FLOW RATE (gpm/SO 2 gpm/sf 11.67*gpm/sfl 1 gpmisf I 2 gpm/sf 1.67* gpm/sf 1 gpmisf 2 gpm/sf 1.67* gpm/sf 1 gpm/sf CARTRIDGE FLOW RATE (gpm) 22.5 1 18.79 1 11.25 1 15 1 12.53 1 7.5 1 10 1 8.35 1 5 * 1_67 gpmisf SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB ' (PSORB) MEDIA ONLY FRAME AND COVER (DIAMETER VARIES) N.T.S. SITE SPECIFIC DATA REQUIREMENTS STRUCTUREID ` WATER QUALITY FLOW RATE (cfs) PEAK FLOW RATE Ids) RETURN PERIOD OF PEAK FLOW (yrs) CARTRIDGE HEIGHT (27", 18", LOW DROP(LD)) NUMBER OF CARTRIDGES REQUIRED CARTRIDGE FLOW RATE MEDIA TYPE (PERLITE, ZPG,PSORB) PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE #1 INLET PIPE #2 OUTLET PIPE RIM ELEVATION ANTI -FLOTATION BALLAST WIDTH HEIGHT NOTES/SPECIAL REQUIREMENTS: * PER ENGINEER OF RECORD GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2, DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3, FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. 5. STRUCTURE SHALL MEET AASHTO HS-20 LOAD RATING, ASSUMING EARTH COVER OF 0'- T AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION, ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. 6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. 7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft). 8. STORMFILTER STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND AASHTO LOAD FACTOR DESIGN METHOD. INSTALLATION NOTES A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HOPE OUTLET STUB AND SAND COLLAR. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. 11 fn .. �� /F"' �" / « " "h I _s fi BILCO SINGLE DOOR ACCESS - (J-2AL H20) OR ENGINEER APPROVED EQUIVALENT (TYP.) 4 4. Q d' a RCP (FROM SEDIMENT _STORAGE BOX) 4 a_ 15" RCP (IN) / / ° ° . \ \ Q INV. = 346.10 4 4.' (FROM SEDIMENT ° \ \ STORAGE BOX) ° a \ V e� Q (44 .. a a a ' as /p • a � �� a 1 l 4 4 4 X 4 �owl G 4 d / a BOTTOM EL. 339.50 4• a 4 4 15" RCP (TO EXISTING CATCH BASIN) 72" CMP (WQ STORAGE) INV. = 340.00 OVERFLOW WEIR 4�j- a CREST EL. = 346.00 ' 1 TOP OF HANDWHEEL TO EXTEND ABOVE WEIR WALL. 15" RCP (TO EXISTING CATCH - -BASIN) - - 15" RCP (OUT) INV. = 339.50 (TO EXISTING CATCH BASIN) OVERFLOW WEIR - LENGTH = 8 FT CREST EL. = 346.00 d. 4 STORMFILTER FLOWKIT OUTLET (TYP.) N RIM EL. = 349.00 TOP EL. = 349.00 ACCESS RISERS AND TOPS DESIGNED BY OTHERS (TYP.) OVERFLOW WEIR LENGTH = 8 FT CREST EL. = 346.00 6" PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 1820 ECCENTRIC VALVE OR ENGINEER -APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HANDWHEEL 15" RCP (IN) a INV. = 346.10 (FROM SEDIMENT STORAGE BOX) ALUMINUM REINFORCED VERTICAL ACCESS LADDER (TYP-) 7Y0 ALUMINIZED CMP WQ VOL STORAGE PIPE a 4 d a Q4 4 CONTRACTOR SHALL ANCHOR LADDER TO BOTTOM OF SEDIMENTATION CHAMBER 6" PLUG VALVE CONTECH STORMFILTER WITH ADHESIVE ANCHOR BOLTS (TYP.) CARTRIDGES AND FLOW KIT 720 ALUM(NiZEI CMP WQ VOL STORAGE PIPE BILCO SINGLE DOOR ACCESS (J-2AL H20) OR ENGINEER APPROVED EQUIVALENT (TYP.) 7 STORMFILTER CARTRIDGES AND ASSOCIATED PLUMBING TO BE INSTALLED PER MANUFACTURER'S a SPECIFICATIONS d 4 . ° 4 a• `Q n .4 \ 9� O \J \ EAl 8'X8' INTERNAL DIMENSION CONCRETE BOX DESIGNED BY OTHERS 6" PLUG VALVE NCDOT STANDARD JUNCTION BOX DIMENSIONS = 4'X4' 4 a 15" RCP 15" RCP (TO STORMFILTER) (FROM ROOF DRAINAGE) _ G 4 2' SEDIMENT STORAGE 4 I SUMP a• 4 4 a 4 11 kv, I •' :• M 8 N�+ z o � N� VJ � A V .tlll/li//flit!! F • S%�- ' SEAL �•� ' 042537 •,"JJS`A/A f E.07/1 SN w w U U s W it W � � c~rf z N 6i N Go co Z N 0 T o O 1 N U2 00 OD i w 5 N N N Qqq Cfl w V-4 aw A E E z o Ww o 0D Lo W 0 0 r W � �5 A V ctai0 o 0 W O - ` ►mot !� PROJECT NO. HTG-17000 FmNAME. HTG17000-SW CHECKED BY. JES DRAWN DY- KEG SCALE: N.T.S. DATE' 12-18-18 SHEET NO. s w _ j 2%1 61 e) WA 1 • :• PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION �.J MCADAMS FACE OF ONE GLENWOOD ON ADJACENT PROPERT" i II i --------------—t— EL.349.80 --————————— — — — — — — EL. 348.85 REAR EXISTING AVG. GRADE PLANE = 349.33' (MOST RESTRICTIVE) ROOF - HIGH POINT Adk 367.79 ROOF - LOW POINT 361.79 LEVEL 01 - MORGAN ST 346.79 MORGAN ST AVG GRADE PLANE 345.79 TRANSPARENCY REQUIREMENT - UD01.5.9: N/A NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UD01.5.10, N/A NO STREET FRONTAGE THIS ELEVATION *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE 2 ACCESSORY STRUCTURE SOUTH BLDG- NORTH ELEVATION SCALE: 1/8" = 1'-0" *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE HATCH DENOTES GROUND STORY TRANSPARENT AREA PER UDO 3.2.6 F1 LEVEL OF ADJACENT SIDEWALK TO RETAIL BUILDING STAIRS UP TO PATIO LEVEL W/ GROUND FLOOR FRONT EXISTING AVG GRADE PLANE = 325.25' (MOST RESTRICTIVE) ENWOOD ON E RTY ROOF - HIGH POINT 367.79 ROOF - LOW POINT 361.79 LEVEL 01-MORGAN ST MORGAN ST AVG GRADE PLANE 345.79 01 - TOTAL WALL AREA ;EN 0 AND 12' ABOVE ADJ. SIDEWALK = LEVEL 01 - TRANSPARENT AREA = LEVEL 01 - TRANSPARENCY % _ TRANSPARENCY % REQUIRED = ACCESSORY STRUCTURE SOUTH BLDG - SOUTH ELEVATION (MORGAN STREET) 1 SCALE: 1/8" = 1'-0" 3 ACCESSORY STRUCTURE SOUTH BLDG - WEST ELEVATION SCALE: 1/8" = 1'-0" 3 *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE ACCESSORY STRUCTURE SOUTH BUILDING - EAST FACADE 4 SCALE: 1/8" = 1'-0" 2 307 SF 218 SF 71% 66% �342.25 LMORGAN ST MOST RESTRICTIVE AVG GRADE TOTAL AVG GRADE = 345.79' (SLOPING SITE - LIDO 1.5.7.4) ACCESSORY STRUCTURE CRITERIA: 3.2.6.D2 - Accessory Structure Max Height of 25' — both buildings are less than this maximum height (refer to elevations) 6.7.1 .A 1. Buildings are incidental to the primary mixed -use building as they are accompanying but not a major part or portion of the development and are found in connection with the principal mixed -use building 2. Buildings are subordinate (smaller in size, scale, and area) to the primary mixed -use building which is allowed and required under its zoning (DX-12-UG) 3. Buildings are subordinate in size having a much smaller size, scale, and area (1500 SF and 2100 SF each) compared to that of the primary mixed -use building (265,000 SF) 4. Buildings provide convenient access to additional retail that the primary mixed -use building would not have space to provide, giving users and the community additional options to use 5 .Buildings are located on the same lot as the primary mixed -use building 6.7.2.E 1. Accessory structures comply with the requirements set forth under section 3.2.6.D2. 2. Accessory structures are located greater than 10' from the primary structure and each other on the same lot. 12.2.a — Buildings meet the definition of an Accessory Structure— any structure or use subordinate in both purpose and size that is incidental to and customarily associated with any primary structure or principal use that is located on the same lot. ROOF - HIGH POINT 367.79 ROOF - LOW POINT 361.79 LEVEL 01 - MORGAN ST OIL 346.79 MORGAN ST AVG GRADE PLANE 345.79 TRANSPARENCY REQUIREMENT - UD01.5.9: NIA NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UD01.5.10: N/A NO STREET FRONTAGE THIS ELEVATION ROOF - HIGH POINT OL 367.79 ROOF - LOW POINT 361.79 LEVEL 01 - MORGAN ST OIL 346.79 OILMORGAN ST AVG GRADE PLANE � 345.79 TRANSPARENCY REQUIREMENT - UDO 1.5.9: N/A NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UDO 1.5.10: N/A NO STREET FRONTAGE THIS ELEVATION HERITAGE 77! PROPERTIES, INC 0-3 HILLSBOROUGH STREET EVELOPMENT ensler 30 Hillsborough St. aleigh, NC 27603 U ed States Fnch ks ctural Engineer Hillsborough Street, Suite Tel 919.239.7836 Fax 919.239.7828 BW FdA = MEP Engineer 2301 Rexwoods Dr, #108 eigh, NC 27603 Raleigh, NC 27607 ited States United States 919.782.1833 Tel 919.747.9884 Date Description 2018.10.12 ASR SUBMISSION #2 Seal I Signature NOT FOR CONSTRUCTION Project Name (ORGAN STREET RETAIL ►UILDING roject Number J0.0279.000 escription JCCESSORY STRUCTURE SOUTH BLDG - ZONING ELEVATIONS Scale Ass° _ 1 1-011 A0n01 0 © 2015 Gensler *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE ACCESSORY STRUCTURE NORTH BLDG - SOUTH ELEV 2 SCALE: 1/4" = 1'-0" HILLSBOROUGH ST AVG GRADE PLANE 351.78 TRANSPARECNY REQUIREMENT - UDO 1.5.9 NIA - NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UDO 1.5.10 NIA - NO STREET FRONTAGE THIS ELEVATION --- EL. 351.30 LINE OF AVG GRADE PLANE = 351.78' (EXISTING GRADING MORE RESTRICTIVE) CANOPY TOP OF STEEL OiL 366.72 ROUND =NT 651 LEVEL 01 OIL 352.05 HILLSBOROUGH ST AVG GRADE PLANE�ST AVG GRADE PLANE RS1 7R LEVEL 01 - TOTAL WALL AREA BETWEEN 0-12' ABOVE ADJ. SIDEWALK = 345 SF LEVEL 01 - TRANSPARENT AREA = 232 SF LEVEL 01 - TRANSAPRENT % = 67% TRANSPARENCY % REQUIRED = 66% BLANK WALL AREA COMPLIANCE - UDO 1.5.10 NO BLANK WALL AREAS THIS ELEVATION ACCESSORY STRUCTURE NORTH BLDG - NORTH ELEVATION (HILLSBOROUGH STREET) 5 SCALE: 1/4" = 1'-0" i *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE ACCESSORY STRUCTURE NORTH BLDG - WEST ELEV 3 SCALE: 1/4" = V-0" 3.2.6.D2 - Accessory Structure Max Height of 25' — both buildings are less than this maximum height (refer to elevations) 6.7.1 .A 1. Buildings are incidental to the primary mixed -use building as they are accompanying but not a major part or portion of the development and are found in connection with the principal mixed -use building 2. Buildings are subordinate (smaller in size, scale, and area) to the primary mixed -use building which is allowed and required under its zoning (DX-12-UG) 3. Buildings are subordinate in size having a much smaller size, scale, and area (1500 SF and 2100 SF each) compared to that of the primary mixed -use building (265,000 SF) 4. Buildings provide convenient access to additional retail that the primary mixed -use building would not have space to provide, giving users and the community additional options to use 5 .Buildings are located on the same lot as the primary mixed -use building 6.7.2. B 1. Accessory structures comply with the requirements set forth under section 3.2.6.D2. 2. Accessory structures are located greater than 10' from the primary structure and each other on the same lot. 12.2.a — Buildings meet the definition of an Accessory Structure— any structure or use subordinate in both purpose and size that is incidental to and customarily associated with any primary structure or principal use that is located on the same lot. TOP OF STEEL OIL 366.72 LEVEL 01 j1 352.05 GRADE PLANE 351.78 NIA- NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UDO 1.5.10 NIA - NO STREET FRONTAGE THIS ELEVATION TRANSPARECNYREOUIREMENT-UDO 1.5.9 NIA -NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UDO 1.5.10 NIA - NO STREET FRONTAGE THIS ELEVATION HERITAGE 4_ PROPERTIES, INC 623 HILLSBOROUGH STREET DEVELOPMENT 2 Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States BVV &A Structural Engineer MEP Engineer 415 Hillsborough Street, Suite 2301 Rexwoods Dr, #108 101 Raleigh, NC 27607 Raleigh, NC 27603 United States United States Tel 919.782.1833 Tel 919.747.9884 0 Date Description 2 2018.10.12 ASR SUBMISSION #2 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET RETAIL BUILDING Project Number 90.0279.000 Description ACCESSORY STRUCTURE NORTH BUILDING - ZONING ELEVATIONS Scale 1 /411 = 1'-011 0 *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE 4 ACCESSORY STRUCTURE NORTH BLDG - EAST ELEV SCALE: 1/4" = V-0" A0n02 © 2015 Gensler MECHANICAL EQUIPMENT SET BACK > 10' PER LIDO 1.5.7.D.3 IC MECHANICAL EQUIPMENT SET BACK > 10' PER LIDO 1.5.7.D.3 NTHOUSE 515.30 — ilk\11,6111, \ iI �I �1I N ROOF 503.30 ■■ .'. � �li r,,Il �,�I �. �I I I II�I I� �I II I I � IF, Ilk ■■ I � .� � I II . LEVEL 10.-'k I- .......... ■ �I �►L *16 II �- I I�-II,-I ■■�II-II- 488.63 ■ J,I04I�1II11 \I - I\ I� I �I I I I ■ ----��II-- � \I \ --: ■ II��� I I I I I I It I I I I I I. I`■ I. I �� I I I I I ■ ■ 101 473.97 ■ ,, - -�I--;I�- - I :I -I` - I ■ I=I` � I I - - iii II I�I I�I I�I I I` ■ 1i `` ■ Owl LF\—M LEV , ■ --� I I `�\ 101� I►�I__ ■ 1 ■ �I\I ��I►\ I--I--�I- ;I �I�I �I- �I \I I \IIF \I ■ I -I ■ I ---:I-; � -I.I ® . � ■' , I\I I I I I® I � I \I \ I F I�IF ■,Itl� ■�11 I\ I I 1 � 1 ■ .. ■ II. I��\�� I. I�I� �� [� I��. I1 ■ l���t I� �� . ■ �■LEVEL 1 ■ � },F IISI 'EftI ■■■ 'i �� _��_ _j j l � �j'�44463 I III �- �-�I �® II��III �-II�-III '�III�CtIIl ■■■■ - NIII - - ■ ��I '' 11' �II II II• \jII :II ■■LU • �1 \\� II\�II qw, II-®-I-- ��� ` I I ■ Ak LU 429.97 II ■ , I �I I � I I \I 'I I ��I I �I �� ®� �lij } � I`j I \I� \� �I` I � I � I I � ■ ■ 1 I I� I I I■ 1 ■ I\ I ■ I (D LEVEL415. ■ ��1 �I� ON 11101 I LU � !�II�I' I \I , ■ \ I I I \I I ®I \I I I ■ `I� `I I I I I`I Itl I \ ®LEVEL400 - �- -� '�' ■ I I I I I� ■. I I I 11�1�1 �I . .1iSO �I�I\,►���i\LEVEL �1� I��I��., i6 h 3,-Jk INI��II 116MEMi��► MINIMUM, ; . ------111------ 1 !rrl�l�l�l�■III — -__ _�371.31 EL 352.85' 2 HEIGHT / STORY COMPLIANCE - LIDO 3.2.6: LIDO 3.3.1 - MAX HEIGHT: 12 STORIES MAX ALLOWED 150' MAX HEIGHT ALLOWED LIDO 3.3.2 - MIN. HEIGHT: 2 STORIES MIN ALLOWED 75% MIN STREET FACING FACADE AT MIN HEIGHT 45MIN. DEPTH OF MIN. HEIGHT FROM FRONT BUILDING FACADE INTO LOT BLANK WALL AREA COMPLIANCE - UDO 1.5.10: NO BLANK WALL AREAS THIS ELEVATION 10 STORIES SHOWN A2'49'- 11 11/16" SHOWN 10 STORIES SHOWN LOT WIDTH : 247' - 6" FACADE AT MIN HEIGHT: 133' - 6" % OF FACADE PER LOT WIDTH: 54% /2\ 221'-3"' SHOWN EL 353.80' 2 353.30 HILLSBOROUGH ST AVG GRADE PLANE 353.33 LINE OF AVG GRADE PLANE = 353.33' (PROPOSED IS MOST RESTRICTIVE) MIXED -USE BUILDING ELEVATION - NORTH (HILLSBOROUGH STREET) 1 SCALE: 1/16" = V-0" OUTDOOR SCREENED EQUIPMENT INCLUDES: 1) COOLING TOWERS 2) ENERGY RECOVERY SYSTEM 3) STAIR PRESSURIZATION FANS INDOOR PENTHOUSE EQUIPMENT INCLUDES: 1) ELEVATOR OVERRUN + EQUIP. 2) ROOF STAIRWAY ACCESS 3) MECHANICAL HEAT PUMPS *REFER TO SHEET A0.15 - ROOF PLAN LEVEL 10 - TOTAL WALL AREA = 1,906 SF LEVEL 10 - TRANSPARENT AREA = 1,772 SF LEVEL 10 - TRANSPARENCY % = 92% TRANSPARENCY % REQUIRED = 20% LEVEL 09 - TOTAL WALL AREA = 1,906 SF LEVEL 09 - TRANSPARENT AREA = 1,743 SF LEVEL 09 - TRANSPARENCY % = 91% TRANSPARENCY % REQUIRED = 20% LEVEL 08 - TOTAL WALL AREA = LEVEL 08 - TRANSPARENT AREA = LEVEL 08 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 07 - TOTAL WALL AREA = LEVEL 07 - TRANSPARENT AREA = LEVEL 07 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 06 - TOTAL WALL AREA = LEVEL 06 - TRANSPARENT AREA = LEVEL 06 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 05 - TOTAL WALL AREA = LEVEL 05 - TRANSPARENT AREA = LEVEL 05 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 04 - TOTAL WALL AREA = LEVEL 04 - TRANSPARENT AREA = LEVEL 04 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 03 - TOTAL WALL AREA = LEVEL 03 - TRANSPARENT AREA = LEVEL 03 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 02 - TOTAL WALL AREA = LEVEL 02 - TRANSPARENT AREA = LEVEL 02 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = LEVEL 01 - TOTAL WALL AREA BETWEEN 0 AND 12' ABOVE ADJ. SIDEWALK = LEVEL 01 - TRANSPARENT AREA = LEVEL 01 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = A2 1,906 SF 1,743 SF 91% 20% 1,906 SF 1,743 SF 91% 20% 1,906 SF 1,743 SF 91% 20% 1,906 SF 1,743 SF 91% 20% 1,906 SF 1,743 SF 91% 20% 1,891 SF 1,091 SF 58% 20% 2,F 44 S 1,240 SF 2 61% 20% 1,736 SF 1,307 SF 75% 66% HERITAGE PROPERTIES, INC -7 HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States lynch Arei Structural Engineer 415 Hillsborough Street, Suite 101 Raleigh, NC 27603 United States Tel 919.782.1833 BW &A MEP Engineer 2301 Rexwoods Dr,#108 Raleigh, NC 27607 United States Tel 919.747.9884 0 Date Description 2 2018.10.12 ASR SUBMISSION #2 3 2018.11.08 ASR SUBMISSION #3 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Project Number 90.0279.000 Description MIXED -USE BUILDING ELEVATION NORTH (HILLSBOROUGH STREET) Scale 1 /16" =1'-0" A0n1 1 © 2015 Gensler MECHANICAL EQUIPMENT SET BACK > 10' PER LIDO 1.5.7.D.3 HATCH DENOTES UPPER STORY TRANSPARENT AREA PER LIDO 3.2.6 F2 HATCH DENOTES GROUND STORY TRANSPARENT AREA PER LIDO 3.2.6 F1 O wO 0 0-LL �O 0 0 '0O LL O= �re Cf)O o O z� 0 O o O O EOLL_ 1 1.1 2 2 HEIGHT / STORY COMPLIANCE - UDO 3.2.6: UDO 3.3.1 - MAX HEIGHT: 12 STORIES MAX ALLOWED 150' MAX HEIGHT ALLOWED LIDO 3.3.2 - MIN. HEIGHT: 2 STORIES MIN ALLOWED 75% MIN STREET FACING FACADE AT MIN HEIGHT 45' MIN. DEPTH OF MIN. HEIGHT FROM FRONT BUILDING FACADE INTO LOT BLANK WALL AREA COMPLIANCE - UDO 1.5.10: NO BLANK WALL AREAS THIS ELEVATION 3 slim 10 STORIES SHOWN /�149' -11 11/16" SHOWN 10 STORIES SHOWN LOT WIDTH : 247' - 1" FACADE AT MIN HEIGHT: 216' - 4" A % OF FACADE PER LOT WIDTH: 87% 139'-3"' SHOWN MIXED -USE BUILDING ELEVATION - WEST (BOYLAN AVENUE) 1 SCALE: 1/16" = V-0" f l % r77 37'-10" 0 N TOP OF PENTHOUSE 515.30 ■ 1� i� �� �� �� ��LEVEL 1 I.■■■■.:.�� .::. LEVEL 1 473.97 If ammIIIIIIII LEVEL 1: 459.30 •LEVEL 1 444.63 11 ��1 • LU ��■1 If LU LEVEL 06 . IMF NMI It �� i� si 1 L ■ �I■1 415.30 is 'I at �� �; 1. , _kI\ ��■■■■■■l 400.63 �I iiLEVEL 03 OlL 385.97 "IF LEVEL 02 OIL 371.30"Ir 0 5o 01 LOBBY OIL 353.30 "-F OUTDOOR SCREENED EQUIPMENT INCLUDES: 1) COOLING TOWERS 2) ENERGY RECOVERY SYSTEM 3) STAIR PRESSURIZATION FANS s INDOOR PENTHOUSE EQUIPMENT INCLUDES: 1) ELEVATOR OVERRUN + EQUIP. 3 2) ROOF STAIRWAY ACCESS 3) MECHANICAL HEAT PUMPS *REFER TQ SHEET A0. 15 - ROOF PL N ME LE TS BACK > 10' PER UDO 1.5.7.D.3 LEVEL 10 - TOTAL WALL AREA = 3,154 SF LEVEL 10 - TRANSPARENT AREA = 2,508 SF LEVEL 10 - TRANSPARENCY % = 80% TRANSPARENCY % REQUIRED = 20% LEVEL 9 - TOTAL WALL AREA = 3,145 SF LEVEL 9 - TRANSPARENT AREA = 1,982 SF LEVEL 9 - TRANSPARENCY % = 63% TRANSPARENCY % REQUIRED = 20% LEVEL 8 - TOTAL WALL AREA = 3,135 SF LEVEL 8 - TRANSPARENT AREA = 2,483 SF LEVEL 8 - TRANSPARENCY % = 79% TRANSPARENCY % REQUIRED = 20% LEVEL 7 - TOTAL WALL AREA = 3,126 SF LEVEL 7 - TRANSPARENT AREA = 2,483 SF LEVEL 7 - TRANSPARENCY % = 79% TRANSPARENCY % REQUIRED = 20% LEVEL 6 - TOTAL WALL AREA = 3,116 SF LEVEL 6 - TRANSPARENT AREA = 2,483 SF LEVEL 6 - TRANSPARENCY % = 80% TRANSPARENCY % REQUIRED = 20% LEVEL 5 - TOTAL WALL AREA = 3,107 SF LEVEL 5 - TRANSPARENT AREA = 2,483 SF LEVEL 5 - TRANSPARENCY % = 80% TRANSPARENCY % REQUIRED = 20% LEVEL 04 - TOTAL WALL AREA = 3,097 SF LEVEL 04 - TRANSPARENT AREA = 2,483 SF LEVEL 04 - TRANSPARENCY % = 80% TRANSPARENCY % REQUIRED = 20% LEVEL 03 - TOTAL WALL AREA = 3,052 SF LEVEL 03 - TRANSPARENT AREA = 1,778 SF LEVEL 03 - TRANSPARENCY % = 55% TRANSPARENCY % REQUIRED = L 20% LEVEL 02 - TOTAL WALL AREA = 3,163 SF LEVEL 02 - TRANSPARENT AREA = 1,971 SF LEVEL 02 - TRANSPARENCY % - TRANSPARENCY % REQUIRED = 62% 20% LEVEL 01 - TOTAL WALL AREA BETWEEN 0 AND 12' ABOVE ADJ. SIDEWALK = 2,632 SF LEVEL 01 - TRANSPARENT AREA = 1,762 SF LEVEL 01 - TRANSPARENCY % = 67% TRANSPARENCY % REQUIRED = 66% ILLSBOROUGH ST AVG GRADE PLANE 2 353.33 LEVEL 01 - FITNESS / RETAIL SUITE 03 OIL 349.80 A2 NOTE REMOVED FAI HERITAGE PROPERTIES, INC HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States _� BVV lynch,&A Structural Engineer MEP Engineer 415 Hillsborough Street, Suite 2301 Rexwoods Dr, #108 101 Raleigh, NC 27607 Raleigh, NC 27603 United States United States Tel 919.782.1833 Tel 919.747.9884 0 Date Description 2 2018.10.12 ASR SUBMISSION #2 3 2018.11.08 ASR SUBMISSION #3 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Project Number 90.0279.000 Description MIXED -USE BUILDING ELEVATION WEST (BOYLAN AVENUE) Scale 1 /16" =1'-0" A0n12 © 2015 Gensler HATCH DENOTES UPPER STORY TRANSPARENT AREA PER UDO 3.2.6 F2 HATCH DENOTES GROUND STORY TRANSPARENT AREA PER UDO 3.2.6 F1 ZL rik LEVEL 01 - FITNESS / 349.80 � A� 0 _ 0 0 0 zZD _J M 00 0 J o� LL_ HEIGHT / STORY COMPLIANCE - UDO 3.2.6: UDO 3.3.1 - MAX HEIGHT: 12 STORIES MAX ALLOWED 150' MAX HEIGHT ALLOWED OUTDOOR SCREENED EQUIPMENT INCLUDES: 1) COOLING TOWERS B B.2 B.H D 2) ENERGY RECOVERY SYSTEM 3) STAIR PRESSURIZATION FANS TOP OF PENTHOUSE INDOOR PENTHOUSE EQUIPMENT INCLUDES: 515.30 A 1) ELEVATOR OVERRUN + EQUIP. — 2) ROOF STAIRWAY ACCESS � — — _ 3) MECHANICAL HEAT PUMPS 4 0 *REFER TO SHEET A0.15 - ROOF PLAN ROOF LEVEL 10 - TOTAL WALL AREA = 1,863 SF LEVEL 10 - TRANSPARENT AREA = 1,774 SF LEVEL 10 - TRANSPARENCY % = 94% LEVEL 10 TRANSPARENCY % REQUIRED = 20% 488.63 LEVEL 09 - TOTAL WALL AREA = 1,863 SF ' LEVEL 09 - TRANSPARENT AREA = 1,733 SF LEVEL 09 - TRANSPARENCY % = 93% _ LEVEL 09 TRANSPARENCY % REQUIRED = 20% 473.97 LEVEL 08 - TOTAL WALL AREA = 1,863 SF LEVEL 08 - TRANSPARENT AREA = 1,733 SF LEVEL 08 - TRANSPARENCY % = 93% LEVEL 08 TRANSPARENCY % REQUIRED = 20% 459.30 LEVEL 07 - TOTAL WALL AREA = 1,863 SF LEVEL 07 - TRANSPARENT AREA = 1,733 SF LEVEL 07 - TRANSPARENCY % = 93% — 0 LEVEL 07 OIL TRANSPARENCY % REQUIRED = 20% orf 444.63 LEVEL 06 - TOTAL WALL AREA = 1,863 SF LEVEL 06 - TRANSPARENT AREA = 1,733 SF a LEVEL 06 - TRANSPARENCY % = 93% LEVEL 06 TRANSPARENCY % REQUIRED = 20% — o 0 429.97 ' o LEVEL 05 - TOTAL WALL AREA = 1,863 SF Q LEVEL 05 - TRANSPARENT AREA = 1,733 SF LEVEL 05 - TRANSPARENCY % = 93% _ LEVEL 05 AL TRANSPARENCY % REQUIRED = 20% = 415.30 o LEVEL 04 - TOTAL WALL AREA = 1,863 SF LEVEL 04 - TRANSPARENT AREA = 1,733 SF LEVEL 04 - TRANSPARENCY % = 93% LEVEL 04 OdL TRANSPARENCY % REQUIRED = 20% 400.63 LEVEL 03 - TOTAL WALL AREA = 1,846 SF °O LEVEL 03 - TRANSPARENT AREA = 1,054 SF LEVEL 03 - TRANSPARENCY % = ZL 57% -__- LEVEL 03 TRANSPARENCY % REQUIRED = 20% 385.97 LEVEL 02 - TOTAL WALL AREA = 1,871 SF °D LEVEL 02 - TRANSPARENT AREA = 1,137 SF LEVEL 02 - TRANSPARENCY % = 61 % TRANSPARENCY % REQUIRED = 20% LEVEL 02 OIL 371.30 LEVEL 01 - TOTAL WALL AREA BETWEEN 0 AND 12' ABOVE ADJ. o SIDEWALK = 1,480 SF ao LEVEL 01 -TRANSPARENT AREA - 979 SF LEVEL 01 - TRANSPARENCY % = 66% - LEVEL 01 -LOBBY TRANSPARENCY % REQUIRED = 66% 353.30 — - ------------ A HILLSBOROUGH ST AVG GRADE PLANE 353.33 LEVEL 01 - RETAIL SUITE 03 347.22 UDO 3.3.2 - MIN. HEIGHT: 2 STORIES MIN ALLOWED 75% MIN STREET FACING FACADE AT MIN HEIGHT 45' MIN. DEPTH OF MIN. HEIGHT FROM FRONT BUILDING FACADE INTO LOT BLANK WALL AREA COMPLIANCE - UDO 1.5.10: NO BLANK WALL AREAS THIS ELEVATION 10 STORIES SHOWN z�\_149' -11 11/16" SHOWN 10 STORIES SHOWN LOT WIDTH : 216' - 2" FACADE AT MIN HEIGHT: 125' - 6" % OF FACADE PER LOT WIDTH: 57% 22V-3"' SHOWN MIXED -USE BUILDING ELEVATION - SOUTH (MORGAN STREET) 1 SCALE: 1/16" = V-0" �i HERITAGE PROPERTIES, INC HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States B VV & i Structural Engineer MEP Engineer 415 Hillsborough Street, Suite 2301 Rexwoods Dr, #108 101 Raleigh, NC 27607 Raleigh, NC 27603 United States United States Tel 919.782.1833 Tel 919.747.9884 0 Date Description 2 2018.10.12 ASR SUBMISSION #2 3 2018.11.08 ASR SUBMISSION #3 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Project Number 90.0279.000 Description MIXED -USE BUILDING ELEVATION SOUTH (MORGAN STREET) Scale 1 /16" =1'-0" Q co CD A0n13 © 2015 Gensler I J`FI.LL / 2 \ MIXED -USE BUILDING ELEVATION - EAST (COURTYARD) 1 SCALE: 1/16" = V-0" ZI TRANSPARECNY REQUIREMENT - UDO 1.5.9 N/A NOT STREET FACING FACADE BLANK WALL AREA COMPLIANCE - UDO 1.5.1 N/A NO STREET FRONTAGE THIS AREA xERITAGE PROPERTIES, INC HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States B&VV �f L Structural Engineer MEP Engineer 415 Hillsborough Street, Suite 2301 Rexwoods Dr, #108 101 Raleigh, NC 27607 Raleigh, NC 27603 United States United States Tel 919.747.9884 Tel 919.782.1833 0 Date Description 2 2018.10.12 ASR SUBMISSION #2 3 2018.11.08 ASR SUBMISSION #3 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Project Number 011 1 • 111 Description MIXED -USE BUILDING ELEVATION - EAST (COURTYARD) Scale 1 /16" =1'-0" Q co CD A0n14 © 2015 Gensler HERITAGE PROPERTIES, INC TOTAL ROOF AREA = 24,51 25% MAX PENTHOUSE ARI UDO 1.5.7.D-3 TOTAL PROVIDED PENTHOUSE AREA = 4,321 PROVIDED PENTHOUSE IS 18% OF TOTAL ROOF ARE PARAPET WALL = 3 FEET A 10 STORY BUILDING IS ALLOWED A PARAPET WA OF 11 FEET (LIDO 1.5.7.1) ZONING PLAN - ROOF 1 SCALE. 1/16 = 1-0 PARAPET WALL = 3 FEET TALL A 10 STORY BUILDING IS ALLOWED A PARAPET WALL OF 11 FEET (LIDO 1.5.7.1) B.8 C.4 HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States B VV &A Structural Engineer MEP Engineer 415 Hillsborough Street, Suite 2301 Rexwoods Dr, #108 101 Raleigh, NC 27607 Raleigh, NC 27603 United States United States Tel 919.747.9884 Tel 919.782.1833 0 Date Description 3 2018.11.08 ASR SUBMISSION #3 Seal / Signature NOT FOR CONSTRUCTION Project Name HILLSBOROUGH STREET OFFICE BUILDING DEVELOPMENT Project Number 0111 1 • 111 Description MIXED -USE BUILDING ROOF PLAN Scale 1 /16" =1'-0" A0n15 © 2015 Gensler 'tiv Administrative Site Review Application 411111,3 i E3ES EERVVICESICES T S (for UDC Districts only) �6 DEPARTMENT TlevelnpmenI Servitex C:usluuler Sert•iue Caen ter I F—ha-x PIL-n. Soiteeft I R:Jcigh, fif 17fi01 G 9 944_ RI Ella 416 ME <; FArhhird Sal ON Le 0I11Lxs 111211- " ;O f:rrrnivi Road I Ratcipp, INC. 2'r,0I I p I 4 .•12c11 When suhmr3irig plans, please check the approprioto building type snd Pndude the Plan Checklist document. BUILDING TYPE FOR O FRCE USE ONLY 0 Da:adipd L� General '"""�"Jenriin5- ❑ Attached ❑ rviked u. F1 Apartment LJ Open Lot w..lyrnd emJenraminov. ❑ Townhou,c eve^rd IJos your;, ry>rect prmft'mv bin I4M40- Me flue Oi$ger or Sketch Plea Review pra[Pv•' it Yea, n; cVh7e rho "Coracf7nd � GENERAL INFORMATION Deve lop m. en L N a me BLOCK 83 PARKING DECK htslde City Limit? DYcs ❑No Zoning Distric I V X-7—I I L Ovoday Distri- (if a.: ph c a;;l ej NIA Prfl,—C Ll- PARKING DECK AND RETAIL Property Addresslas) 701 & 709 H#LLSBOROUGH STREET IN -[or stepptloratnr HI LLSBOROUGHIBOYLAN Wake Coo my Properly identif ca l ion NUmberjsl for rscn parxl to which Lhesa gui culines'A II apply: P-LN_ P-I"N. P-I N- 1703490106 "'N 1703399107 1 What h your poled tgpCT ❑ ApurL—,l 0 Elrcrly Fo Ab- ❑ H-p.ui. ❑ HpI-L-W,wtcl, E: ON- ❑ Irt mil R—W.irrial ❑ N--Reudenteal Cnndn ❑ ❑ Shopping Center ❑ IS— ❑ Ird—rill Riiijdrlq, ❑ Duplex ❑ Telmon-munlEr.lon Tower ❑ Ik6@lous Instituttons ❑ riesldemlal Cando I:• Rota -I O oxtage Court A U:k,-If other, pkn—I—iLr_: PARKING DECK Pe r C' ty Coda Section 1n.2. R-D. 1, summa HrP viP Inrolert win rk swap" for ad Ell Lions, changes of rrSp, or ntr"ppanWYLper Chapter a of Lhe DDO I,•ndi a re imaa— or parking requrerne nl s" �110WFSCOPP THE PROPOSED DEVELOPMENT INCLUDES A PARKING DECK WITH A SVIALL PO RT ION OF RETAIL ALSO INCLUDED ARE THE INFRASTRUCTURE AND UTILITIES REOUIREID TOSERVE THE PROPOSED BUILDINGS I^er C•tv Code Chapter 8, 5u7ima•i2e it Your prulbLL ra eul res either a des IgH aQ usLm ant, ur Section 1.0 - Ahernwke DESIGN AD]USTIBENT Admimstry Uve 4c OR AD MIN ALTERNATE N/A Camp-"'' HERITAGE PROPERTIES, INC "am& sl RYAN BLAIR CL1EN EVELDPER Address OWNER 501 FAIR_MOUNT AVENUE, SUITE 101, TOWSON, MD _ P'lD-410-769-6139 Email RBLAIROHPIMD.COM Fax N/A I [nmpa-MCADAMS Nama{4,RICK SLATER CONSULTANT I Contact Pe rson for Address 2905 MERIDIAN PARKWAY, DURHAM, NC Plansl Phan- 919-361-5000 `'mall Sl-ATERQMCADAMSCCt.G•0M rmf N/A FAQ I OF 3 W W W.iiALF1GH-VC .G0V REVISION 05.13.16 DEVELOPMENT TYPE & SITE DATA TABLE (Applicable to all developments) Zoning informatinn Building Information Zonin, District(s) NX-7-UL Proposed building uses) PARKING DECKiRETAIL If more19an one district, provide the ac•eareof each: NIA Existing Buildings) sq" ft gross5.940 Proposed Build ing(s) sq" ft, grocs267,333 Overlay Distri et NIA Total SileAcres Inside City Limits ® Yes 0 N❑ 0.82 ae Off street park lng: n equl red 29 Provided 693 COA I Cart lfkate of Approprl ntenass]vase#N/A ToLaI sq, ft. gress(exiAing & pntpvsed)267 333 Proposed height of hu 116ing(s]89'-63116"— #of storl eK1 (parking deck Ievels excl uded) BOA (Bo a rd of Adi u stment) c a se It A NIA Celli ng h eight of l" Floo r 13' minimum CUD (Conditional Usc Distr:ctl casettZ 70-94 5tormwater Information ExisU r,g Im pervious Surface 27,634 acre quare feel Proposed ImperVio LIS Surface 35,860 acre sq.Iar, fee flood Hazard Area ❑ Yes 0 No Ifyes, please provide: Aliuvlal Solls N1A Tlond Study NIA FEMAMap 'anel4 NIA Neese River Buffer 0 Yes ❑ Ne Nletlarlds ❑ ves 0 Yc FOR RESIDENTIAL DEVELOPMENTS 1" Total It Of Apartment, Condo In ini um or Residential Units NIA 5" Bedroom Units: 1hr tar 36r 4br or more NIA 2" Tntal #[r Cnng"Pgmtp[a re Or 1. Ifie Cm re meal ling Unl is NIA 5" InQI Da•ve•op7rp nt 2.2.7 N/A 3" Total Number of Hotel Units NIA 7" Open Space [only)air Amenity N/A d. Overall Total4 Of Dwelling Units (1-6Above)N/A E. Is yo ur proj ecI a wt Lage wu rL? ❑ Yes 1- No SIGNATURE BLOCK IAppHcahle to all developments] In Filing this clan as the prop a rty nwner(sj, Ifwe do hereby agree and firmly bird ourselves, mylo ur heirs, Elva utors, administrators, successors and ass Igoe jointly and serelally to Caro truct all irnp ruverrlenis and make all dedications as shown on this proposed deve lop me ell plan as approved by the City. t herahy rl s gnat, R I C K SLATER, PE to serve as my agent rega•ding thls appl licatlo In, to receive and �espend to adm inist ra live ce m merits, to resu brr it plans en my beha.f and to represent mein any public meeting regard irg L% application" Ilwe have read, acxnowl edge and of -min that this project is confo rming to all application requi renrents applicable with the propose ddeve lop ment so- 5 ifiligned A SDate 1 D/15J2418 �T Jnhn F. Hn Imp.%, Jr" Prea:dent, J.T. Hnnhy and Snn, Inc- Prir-ted Na in fit, le Signed' -sr` 'Date 1011.r,; 2:]7R Ryan J. RN:r I Partner Hp rltagp Pro nertivc, Inc.. R Gl PnwnM Twn, LLC Printed Name& TRIG PAGE 2 OF 3 WWW.HALE1C;HVC'.GOV REVISION 05.13.16 VICINITY MAP ADMINISTRATIVE SITE REVIEW CASE NUMBER: XX-XX-XX TRANSACTION NUMBER*,� ZONING CONDITIONS RALEIGH,NORTH LINA PROPERTY PIN: 1703399107 ORDINANCE NO. (1994) 499 ZC 353 Effective: 9.6-94 0 Z-70-94 Hillsborough Street, south side, between S. Boylan Avenue and 5t. MWs PROJECT NUMBER: HTG- 1 1 Street, being Parcel 9107, Block 39, Tax Map 1703.06, rezoned to Neighborhood Business Conditional Use D1S1r1C1. Conditions: DATE: OCTOBER 16, 2018 f.Dfld1 1. Only uses allowed in the Buffer Commercial Zoning District will be permitted on this property. 2. There will be no vat dipping procedure carried on, on the premises in question. ZONING CONDITION RESPONSES: OWNER/DEVELOPER: 1. ALL USES SHOWN WERE ALLOWED IN THE OLD BUFFER GIENWOOD TWO, LLC COMMERCIAL ZONING DISTRICT. 2. NO VAT DIPPING IS PROPOSED. 501 FAIRMONT AVENUE, SUrFE" 101 TONMSON, MARYLAND 21286 CONTACT: RYAN BLAIR PHONE: 410-769-6139 E M A I L: RBLAIR�HPIMD.COM PROJECT CONSULTANTS: ENGINEER. - THE JOHN R. MCADAMS COMPANY, INC PHONE: 919-361-5000 EMAIL: SLATEROMCADAMSCO. COM SURVEYOR: THE JOHN R. MCADAMS COMPANY, INC PHONE: 919-361-5000 EMAIL: SLATEROMCADAMSCO. COM Know whaYa below. Call before you dig. ARCHITECT: GENSLER PHONE: 919-239-7838 EMAIL: SCOT1 LAHR@GENSLER.COM PARKING/STRU • KIMLEY-HORN AND ASSOCIATES, INC PHONE: 919-653-6649 EMAIL: MATT. S R0y HORN. C0M[ CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. N CAR • A =vC 1.09 Y '�•,IIII111j1`` O LL�Qo U z DO >Cu OI C' Q ~ Z U = F-- _ (n Q LJ Ld � O m if7z� F-- UJ z Q = U w U 0OJ _ J Ld z m � O Q SHEET INDEX C-1 EMSTING CONDITIONS C-1A CURRENT RECORDED PLAT C-2 PROJECT NOTES C-3 DEMOLITION PLAN C-4 SITE PLAN C-5 GRADING AND STORM DRAINAGE PLAN C-6 UTILITY PLAN LS-1 LANDSCAPE PIAN & DETAILS D-1 SITE DETAILS D-2 SITE DETAILS D-3 WATER DETAILS D-4 SANITARY SEWER DETAILS D-5 STORM DRAINAGE DETAILS D-6 STORM DRAINAGE DETAILS BUILDING ELEVATIONS (BY GENSLEm A0.01 PARKING GARAGE ZONING ELEVATIONS SOLID WASTE COMPLIANCE STATEMENT: 1. THE DEVELOPER ACKNOWLEDGES THAT THEY HAVE REVIEWED AND ARE IN COMPLIANCE WITH THE REQUIREMENTS SET FORTH IN THE SOLID WASTE DESIGN MANUAL. 2. THE SOLID WASTE REMOVAL FOR THIS PROJECT WILL BE HANDLED BY A PRIVATE SERVICE (SEE SITE PLAN SHEET C-6). 3. REFUSE WILL BE COLLECTED IN CENTRAL COMPACTOR AND/OR DUMPSTERS AND RECYCLING AREAS WITHIN THE SITE. 1. WITHIN THE AREA OF A DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMING OR PARKED VEHICLES BETWEEN THE HEIGHTS OF TWENTY-FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB ELEVATION OR THE NEAREST TRAVELED WAY, IF NO CURBING EXISTS. 2. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS —OF —WAYS, NOT INCLUDING AN ALLEY. NOTE: NO TREE CONSERVATION PLAN REQUIRED DUE TO TOTAL SITE AREA BEING LESS THAN 2.00 ACRES. UDO 4.7.4.11 NOTE: STORMWATER MANAGEMENT FOR THIS SITE WILL BE ACCOUNTED FOR UNDER A SEPERATE COVER WITH A SHARED FACILTIY. ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS SPECIFICATIONS AND DETAILS. MCADAMS THE JOHN R. MCADAMS COMPANY, INC. 2905 Meridian Parkway Durham, North Carolina 27713 License No.: C-0293 919. 361. 5000 ■ McAdamsCo. corn Contact: Rick Slater, PE Slater@mcadamsco.com x P]RIEILIMINAIRY DRAWING — NOT RELEASED FOR CONSTRUCTION N/F WILLIAMS- CROSS INVESTMENT CO INC 706 HILLSBOROUGH ST PIN 1703-39-9454 N/F DB 1408, PG 569 HILLSBOROUGH 630 LLC 0.67 AC. - i I 630 HILLSBOROUGH STREET ZONING: OX-7-UL I I PIN 1703-49-1348 DB 16997, PG 1152 - - L ti FIRE HYDRANT 0.30 ZONING: NXC7-UL �w-W �w �w�w R-SS�9O-S� Wow-- E 8"VCP(E)=352.21 w__�� � ❑ - - �w�w c-G�c- W-wGAG _wW� GAS LINE - - - - - W W W�WG wG G��-G G EXISTING ss _ W wG G G G G ss ss ss W W c HILL,SB® ss s ss w� w W 8" CIP W/L ®U lX T. ss ss ss s ss - 81, SS 3 0 -- w�W-w _ 3 SS SS (VARIABLE WIDTH PUBLIC R/W) _ - - ss 3 SS SS ss -{�- - ss SS ss Ss - SSMH - RIM=355.14 - - 3n 8'VCP(N)=348.98 8'VCP(E)=348.61 T SIDEWALK 8"VCP(W)=348.73 E 6Qy / O 3l Od - oj", E �cr� Fo N/F THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. PIN 1703-39-7175 DB 12630, PG 838 1.16 AC. ZONING: OX-7-UL 0 1� Z 'o 'o 0 03 O S 86'32'29" E 90.88, FO�Fo Fo \ S� / ASPHALT CANOPY - 1 I x I ® x CONCRETE ® PATIO 2-STORY BRICK \ BUILDING N/F JT HOBBY & SON INC 709 HILLSBOROUGH ST. PIN:1703-39-9107 DB 14313, PG 1726 - 0.39 AC. ® ZONING: NX-7-UL-CU I OC / 1 2-STORY BRICK BUILDING �I 1-STORY BRICK BUILDING ASPHALT - x x x a WALLI � x ;0 I N M x 0 I N x x I x I x x FENCE WITH ' BRICK COLUMNS PAINT BUILDING OVER PROPERTY LINE x_ �x-�_ __�_x x_x_x WALL N 86'50'01" W 90.29' 2-STORY FRAME BUILDING N/F SAMIH T & REBECCA A YEHIA RVCBLE TRUST THE YEHIA, SAMIH T TRUSTEE 704 W. MORGAN ST. PIN 1703-39-9004 DB 15864, PG. 676 0.12 AC. ZONING: NX-7-UL FO FO 86'32'29" E C� ASPHA J N/F FMW AT 701 HILLSBOROUGH LLC 701 HILLSBOROUGH ST PIN 1703-49-0106 DB 16937, PG 2509 BM 1987, PG 1251 0.43 AC. ZONING: NX-7-UL 1-STORY BLOCK AND METAL BUILDING M SIGN CONCRETE J ASPHALT 00 oe, \ 10O 06 06 r CONCRETE 1 WALL X �(' SSMH RIM_35 .13 8"VCP(S=346.01 BUILDING 0 R PROPERN LI E WALL WALL N 86'S0'01 W 00.23' 7 - - 3-STORY BRICK BUILDING N/F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING° NX-7-1111 OG I I 0 I 0 'o - 3n 3n 3n 3n - S87'03'40"E 238.51� - BLOCK 83 PROJECT ZONING: DX-12-UG TDER SEPARATE COVER TRANS# 559068) r LEGEND QQ EXISTING IRON PIPE ACCESSIBLE PARKING ® IRON PIPE SET IRRIGATION CONTROL VALVE A CALCULATED POINT FLOOD LIGHT ® BORE HOLE OR MAIL BOX QS SANITARY SEWER MANHOLE (9 MONITORING WELL © SANITARY SEWER CLEANOUT � SAP SIAMESE CONNECTION m WATER VALVE SIGN ® WATER METER O WELL FIRE HYDRANT ® WATER MANHOLE ❑p TELEPHONE PEDESTAL 0=0 LIGHT SINGLE QT TELEPHONE MANHOLE E�OC LIGHT DOUBLE p ELECTRIC BOX ® CABLE BOX LIGHT POLE FIBER OPTIC VAULT � POWER POLE ypy SPRINKLER HEAD Wi CURB INLET SD STORM DRAIN PIPE QD STORM DRAINAGE MANHOLE OU OVERHEAD UTILITY LINES ❑ YARD INLET W WATER LINE FA-Cl AIR CONDITIONER SS SANITARY SEWER LINE FX-X-X-Xl ADDRESS BOX T TELEPHONE LINE • BOLLARD G GAS LINE FIRE CONNECTION LIE UNDERGROUND ELECTRIC ® FIBER OPTIC MARKER UT UNDERGROUND TELEPHONE © GREASE PIT -X X- FENCE LINE � V H o� o J o� � P � I ) I I I P JIN II a V) UIN I (o Co I I I g ~ IN O ti JB I0 I (ASSUMED LOCATION) RIM=350.40U. c�+ ~I o INV IN(N)=346.41 H N I INV OUT=346.41 N I GRAPHIC SCALE o 20 0 10 20 40 N87q5r3-7V -208.13' JI 1 inch = 20 ft. sN So f .40 0 0 I N W w I f I N J 0 I l f ou j N - - T N -_ 0 OU - -- --- --- --- o no no - i - 0 f I I co_., 00 r ti SIDEWALK n0 I SSMH O I RIM=352.57 I8"VCP(N)=344.38 I N/F N/F 8'VCP(S)=344.26 o y- THE COLEMAN GROUP LLC PLANNED PARENTHOOD OF GREATER I 705 W MORGAN ST I RALEIGH INCFIRE PIN 1703-38-8847 100 S BOYLAN AVE HYDRANT I7 I DB 15399, PG 1 I PIN 1703-38-9868 I� I II 0.29 AC. DB 4798, PG 489 ZONING: OX-7-UL 0.47 AC. ZONING: OX-7-UL CB TOP=351.99 12"RCP(E)=349.47 JB RIM=352.17 18"RCP(E)=349.34 SIDEWALK 12"RCP(W)=349.46 12"RCP(NW)=359.58 T - - - - - - - - - _ _ _-_ ------ - - - - no no no \ � 20 \ CB TO ����/T EXISTING®j� �0 12 /1 s MORGAN ST. (VARIABLE WIDTH PUBLIC R W)\ -no- - -� no r0 Fo -- N/F CROCKER FAMILY PROPERTIES, LLC 615 W MORGAN ST PIN 1703-48-1885 DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL CO 0 4 v • O t` �Nm 090 N d �0 00 �z00 o� o� C9 �." cr) 6 0) � A V v� O W a Mz 00 W r_-I 4]� O 1--1 z W O14 w W O I4 O z W LO O O w 5 z wwO O M A R O z z z PROJECT NO. H TG-18010 FILENAME: HTG18010-XC1 CHECKED BY: RSS DRAWN BY: iM S SCALE: 1�� _ 20' DATE: 10-16-18 SHEET N0. C i x PRELIMINARY DRAWING - NOT RELEASED FOR, CONSTRUCTION �� MCADAMS z" 211 II v CJ VICINITY MAP THIS CtiRTIFIES THAT TEE UNDMSIGNED I5 (ARE) THE 9WJER(S) OF THE PROPERTY SNOWN ON THIS MAP HAYING ACQUIRED TITLE SNERVIO BY DEED(S) RECORDED IN Tt1L+ OPFICE OF THE RPIGISTER OF DEMS OF WKe COUNTY, NCRTR CAROLINA, OR CI'I►R+RWISE, AS SHOW BELOW. AND THAT BY SURM15SION OF THIS PLAT OR MAP, FOR APPROVAL, I (WE) DO DEDICATE TO TM CITY OF MEIOH, FOR PUBLIC USE ALL STREETS, EASF148M, RP2173 OF SPAY AND PARKS SHOW 7"M1M FOR ALL LAWFUL PURPOSES To MICH THE , CITY MAP DEVUM OR ALLOW THE SANG! TO BE USED AND UPON, AC'C'EPPAMM T ITFR" IN ACCORDANCE WITH ALL CITY PO[. M. RA 9INAHCF;, ANIn P=LATICtC OR CONDITIONS CIF SHE CITY Or RALEI0i FOR THE SE7,IF.FIT OF THE I+MIC, SAID DMICATION SRALL Be IRREVOCABLE; PIUaVED ANY DEDICATION Ce EMEMEIM FOR SA" DRAINAGE ARE NVC NAPE TD THE CITY OF RAi.EICH Un ARE IRREVOCABLY MADE TO THE SUBSEOUF.NT OWWRS OF AM AND ALL PF40MTIES 511CWN HEREON FOR THEIR LMF AND MNEFIT .�SIB7ECT TO CONDITIONS OF SUR,ECY'I416 f Bj (C) (D t AND (F) OF. SFJL`i'IO[j I —SPX 1'i0N 4 C— �^fORN DR.�IN},GE POI.ILY' (RE9]LR 11 (1970}-742 Al I SAME MAY BE FROM 71ME TO TIME AMFNSW.1" ' PROPEP" OWNER ��..r.�� — _ - CASS f I,,J THE UND90SIGh9b CITY CLERK AND TREASURER OF `I-Trm CITY OF RALEIGH, DO HERE13Y CERTIFY THAT T-HE CITY COUNCIL OF THE CITY OF RALEIGH ON DAY OF 19 APPROVED THIS PLAT OR MAP AND ACCEPTED THE DEDICATIONS AS SHOWN THEREON BUT ON THE FURTHER CONDITION THAT THE CITY ASSUMES NO RESPONSIBILITY TO OPEN OR MAINTAIN THE SAME, UNTIL IN THE DISCRETION AND OPINION OF THE GOVERNING BODY OF THE CITY OF RALEIGH IT IS IN THE PUBLIC INTEREST TO DO SO. DEPTUY CITY CLERK AND TREASURER DATE STATE OF NORTH CAROLINA, WAKE COUNTY, I, J. FRED DAVIS, JR., CERTIFY THAT THIS MAP WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SIPERVISI0% THAT THE RATIO OF PRECISION AS CALCULATED BY LATITUDES AND DEPARTURES IS 1/Z0j04O'O- , THAT THIS MAP WAS PREPARED IN ACCORDANCE WITH G.S. 47-30 AS AMENDED. WITNESS r HAND AND SEAL THISroc DAY OF a. .... I I. a 0A 3Fi r,q"►V oo� 4�' _. NiRTH CAROLINA - WAKE COUNTX"A �p ►y,��� I, A NOTARY PUBLIC OF THE C NTY AND STATE AFORE-- P0.1N;- ��RAr y SAID, CERTIFY THAT J. FRED DAVIS, JR., A REGISTERED C,. ' �•ss LAND SURVEYOR, PERSONALLY APPEAREU BEFORE ME THIS - N�ZARY DAY AND ACIQIOWLEDGED THE EXECIPPION OF THE FOREGOING * * * � CD, U LA INSTRUMENT. WITNESS MY HAND AND OFFICIAL SEAL THIS DAY OFu NORTH CAROLINA - WAKE COUNTY THE FOREGOING CERTIFICATE ........ OF ........ _ C a.iN 0, Pa r i�e.r NOTARY IS CERTIFIED BE CORRECT. THIS INSTRUMENT WAS PRESENTED FOR REGISTRATION AND RECORDED IN THIS OFFICE. rl THIS7S DAY OF LIA 1C_AT4. 'CLACKP..M. KENNETH C. WILKINS■ REGISTER OF DEEDS By CLA - I um, C� j� REGISTER OF DEEDS C r. r5 5e gnW SCAI RECORDED IN BOOK OF MAPS', rgg7 PAGE, jp��l�' ,NA h'F I,"� T , , IS TRY '- ( %4 G- nrv-.= - ❑+�7N.ISt7g3r-^µq.yJ .4n-.04w1 (7 �Ib�hNta �, ST&E OF NORTH CAROLINA, WAKE CQUNW, I, CATHY A. PARKER NOTARY PT3BL IC, DO CERTIFY THAT -� r- r., nF� PERSONALLY APPEARED BEFORE ME THIS DAY AND ACKNOWLEDGED THE DUE EXFrr ON OF THE FOREGOING INSTRUMENT. WInw-55 MY HAND AND OFFICIAL, SEAT, THIS _� c �� DAY OF 19 g2 ';LVWTARY PUBLIC Mr Cammiss'nn E=plrts 4•34.91 k A p r G+�R * ** L740 • pUBOP, p 1. *1 0 E I.P. EXIST. IRON PIN J.P.S. IRON PFN SET P.P. POWER POLE P-8 T. OVERHEAD POWER 8 TELEPHONE T. OVERHEAD TELEPHONE THIS IS NOT A SUBDIVISION BUT A RECOMBINATIOX GF PREVIOUSLY PLATTED PROPERTY. ' _7-2L 87 GEQRG� B. �PMAN OAT£ Director at Planning THIS PLAT NOT TO BE RE ORDER AFTER _ _DTI'! DAY OF ,L 1 COPY TO BE RETAINED FOR -SHE CITY. THIS PLAT IS C�IN ❑OUT OF THE CITY LIMITS. CALF Qp Fl�Q��VhUf. I c ti.. S1 •..� Fs4�1 ,a �i,C�W4..14 L.I= -q4 Cinx , SURVEY DATE:4UGUST 24)984 (R' t) 8� RECOMBINATION OF; Date: DULY-;-1-+SR7 Sheet PARCEL 10 AND FI Scale: r' = 20 PROPERTY OF; J, FRED DAVIS. JR., INC. JOHNSON'S JEWELERS INC. If 6e �B w'" plar.ninq Engineering -Surveying I erl y, RAl SIGH, N C Of RALEICH, NAhC M c I�r O U �INdcr) rh Cq orb da4 U woo z• �0�o 00 z ao Nam co Q � O) VJ V ,,,+�, 1111111,1j N CAR G �0 F V-S %009 S �. tiG � NE�• �Q- .' ,1j111111sill % z O 0-4 W a f� 1�1 E-I E-1 O O a w W O > 1-4 C40 W � O z O I W 5 z a � wwo A M F� � W I•_I � w O U Z O z W Z U !r � PROJECT NO- H TG-18010 FILENAME: HTG18010—XC2 CHECKED BY: RSS DRAWN BY: JM S SCALE: N. T. S. DATE' 10-16-18 SHEET N0. C-1A x IPRIEILIMINARY DRAWING — NOT RELEASED FOR CONSTRUCTION TI MCADAMS a� v c v L U L c E Q 00 M LO CN 0 w 0 0 v+ 3 v z i 0 0 oo i v+ c .3 v 0 c a� L i c v IL a) V) v N E v i 0 i O O 0 i i i N U U L iZ EROSION CONTROL NOTES 1. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN 7 DAYS SEE TABLE BELOW AFTER FINAL GRADE IS REACHED ON ANY PORTION OF SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN 7 DAYS (SEE TABLE BELOW) OF DISTURBANCE TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE, BUT WILL REMAIN DORMANT (UNDISTURBED) FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2. ALL CUT AND FILL SLOPES AND CHANNEL SIDE SLOPES WHICH ARE NOT TO BE PAVED, SHALL BE SEEDED UNTIL A GOOD STAND OF GRASS IS OBTAINED IN ACCORDANCE WITH: A. 100 LBS. PER 1,000 SQUARE FOOT GROUND LIMESTONE OR EQUIVALENT. NO SOIL TEST REQUIRED FOR INITIAL ESTABLISHMENT. B. 20 LBS. OF 10-10-10 FERTILIZER OR EQUIVALENT PER 1,000 SQUARE FOOT. C. VARIETIES TO BE SEEDED: C.1. SPRING SEEDING - MARCH 1 - APRIL 30; SPRING OATS 2.5 LBS. PER 1,000 SQUARE FOOT. C.2. SUMMER SEEDING - MAY 1 - AUGUST 1; WEEPING LOVE GRASS AT 2 OZ. PER SQUARE FOOT MIXED WITH 1 BUSHEL OF SAWDUST FOR UNIFORM SEEDING. C.3. ASPHALT TACK AND STRAW MULCH 6 GALLONS PER 1,000 SQUARE FOOT. ALL SEEDING SHALL BE MULCHED. 3. CITY ENGINEER AND OTHER APPLICABLE AGENCIES SHALL MAKE A CONTINUING REVIEW AND EVALUATION OF THE METHOD USED FOR THE OVERALL EFFECTIVENESS OF THE EROSION CONTROL PROGRAM. AN APPROVED EROSION AND SEDIMENT CONTROL PLAN MAY BE AMENDED BY THE APPROVING AUTHORITY IF ON -SITE INSPECTION INDICATES THAT THE APPROVED CONTROL MEASURES ARE NOT EFFECTIVE IN CONTROLLING EROSION AND SEDIMENTATION OR IF BECAUSE OF CHANGED CIRCUMSTANCES, THE APPROVED PLAN CANNOT BE CARRIED OUT. 4. CONTRACTOR SHALL LOCATE AND VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 5. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 6. EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED SO THAT SEDIMENT LADEN RUNOFF FROM THE SITE WILL NOT ENTER STORM DRAINAGE FACILITIES. 7. PROPERTIES AND RIGHT-OF-WAY ADJOINING THE SITE SHALL BE KEPT CLEAN OF MUD OR SILT CARRIED FROM THE SITE BY VEHICULAR TRAFFIC OR RUNOFF. ANY MUD OR SILT THAT INADVERTENTLY GETS INTO ADJOINING PROPERTIES OR RIGHT-OF-WAY SHALL BE REMOVED IMMEDIATELY BY THE CONTRACTOR. 8. ALL CONSTRUCTION TRAFFIC SHALL ENTER AND EXIT THE SITE VIA THE CONSTRUCTION ENTRANCES. 9. EXCAVATED MATERIAL FROM TRENCHES SHALL BE PLACED ON THE UPGRADE SIDE OF THE TRENCH TO ALLOW MATERIAL TO ERODE INTO THE TRENCH. 10. CONSTRUCTION MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF GRADING CONTRACTOR UNLESS OTHERWISE NOTED, AND ONLY AFTER PERMISSION BY THE GOVERNING AUTHORITY. 11. SILT FENCE OUTLETS SHOWN ON THESE PLANS ARE BASED ON THE BEST TOPOGRAPHIC INFORMATION AVAILABLE AT THE TIME OF DESIGN. CONTRACTOR TO FIELD VERIFY AND ADJUST LOCATIONS OF SILT FENCE OUTLETS AND/OR PLACE ADDITIONAL OUTLETS TO INSURE THAT ALL LOW SPOTS ALONG THE SILT FENCE HAVE AN OUTLET. GENERAL DRIVEWAY NOTE 1. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS -OF -WAYS, NOT INCLUDING AN ALLEY. TRAFFIC CONTROL NOTES 1. THE CONTRACTOR SHALL CONDUCT ALL WORK IN A SAFE MANNER AND WITH A MINIMUM AMOUNT OF INCONVENIENCE TO TRAFFIC. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL AND SHALL ADHERE TO THE PROVISIONS OF THE MUTCD (MOST CURRENT EDITION). 3. PRIOR TO START OF WORK, A PRE CONSTRUCTION MEETING MUST BE SETUP WITH THE CONTRACTOR AND THE CITY OF RALEIGH TRANSPORTATION FIELD SERVICES STAFF. CONTACT ENGINEERING INSPECTIONS AT 919-996-2409 TO SET UP THE MEETING. 4. THE CONTRACTOR SHALL OBTAIN A RIGHT-OF-WAY OBSTRUCTION PERMIT FOR ANY WORK WHICH REQUIRES THE TEMPORARY CLOSURE OF A STREET, TRAVEL LANE, PARKING SPACE OR SIDEWALK FROM RIGHT-OF-WAY SERVICES AT LEAST 48 HOURS IN ADVANCE. 5. A TEMPORARY STREET CLOSURE REQUEST MUST BE SUBMITTED AT LEAST A MINIMUM OF TWO WEEKS PRIOR TO THE START OF WORK. SEE "RIGHT-OF-WAY CLOSURES" ON WWW.RALEIGHNC.GOV. SEND THE RIGHT-OF-WAY OBSTRUCTION PERMIT REQUEST TO RIGHTOFWAYSERVICESORALEIGHNC.GOV. 6. THE CONTRACTOR SHALL HAVE A COMPLETE SET OF CONTRACT DOCUMENTS AS WELL AS ALL PERMITS, APPROVALS AND EASEMENTS ON THE JOB SITE AT ALL TIMES. 7. THE CONTRACTOR SHALL REPAIR ALL DAMAGED DRIVEWAYS, DRIVEWAY PIPES, CURB AND GUTTER, SIDEWALKS AND STREETS TO EXISTING CONDITION OR BETTER. 8. SIDEWALKS MUST BE ACCESSIBLE TO PERSONS WHO ARE VISUALLY IMPAIRED AND PEOPLE WITH MOBILITY DISABILITIES. EXISTING PEDESTRIAN ROUTES AND ALTERNATE PEDESTRIAN ROUTES, DURING CONSTRUCTION, WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). PAVEMENT MARKING NOTES 1. ALL PAVEMENT MARKINGS SHOWN IN THESE PLANS FOR CITY OF RALEIGH MAINTAINED STREETS ARE SUBJECT TO FINAL APPROVAL FROM PUBLIC WORKS TRANSPORTATION OPERATIONS DIVISION. CONTRACTOR SHALL CONTACT TRANSPORTATION OPERATIONS AT 919-996-3030 FOR COORDINATION AND FINAL APPROVAL PRIOR TO PLACEMENT OF ANY PAVEMENT MARKINGS. MARKINGS WITHIN NCDOT RIGHT-OF-WAYS SHALL BE IN COMPLIANCE WITH NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL SIGNS & PAVEMENT MARKINGS ASSOCIATED WITH THE PUBLIC STREET SYSTEM WILL REQUIRE APPROVAL BY CITY COUNCIL TO BE ORDINANCED FOR ENFORCEMENT. 3. ALL PAVEMENT MARKINGS SHALL BE PLACED PER THE NCDOT DIVISION 12 STANDARD DETAILS. BICYCLE LANE MARKINGS SHALL BE PLACED PER CITY OF RALEIGH STANDARD BICYCLE FACILITIES DETAILS. GENERAL RAILROAD NOTES 1. CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF THE NORFOLK SOUTHERN'S NSCE-8 SPECIFICATIONS. 2. PIPELINE AND CROSSINGS TO BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH LAST APPROVED AMERICAN RAILWAY ENGINEERING AND MAINTENANCE OF WAY ASSOCIATION SPECIFICATIONS FOR PIPELINES CONVEYING FLAMMABLE AND NON-FLAMMABLE SUBSTANCES. 3. BLASTING NOT PERMITTED. SITE PLAN NOTES 1. NON -ALLEY LOADED DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 20 FEET FROM THE INTERSECTION OF TWO STREET RIGHT-OF-WAYS. THE MINIMUM CORNER CLEARANCE FROM CURB LINE OR EDGE OF PAVEMENT OF INTERSECTING STREETS SHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY OF THE RADIUS OF CURVATURE, OR 20 FEET FROM THE INTERSECTION OF RIGHT-OF-WAY LINES, WHICH EVER IS GREATER. THE RADIUS OF THE DRIVEWAY SHALL NOT ENCROACH ON THE MINIMUM CORNER CLEARANCE. REFER TO SECTION 6.5 OF THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL FOR ADDITIONAL DETAILS. 2. WITHIN THE AREA DEFINED SIGHT TRIANGLES SHOWN ON THESE PLANS, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL,FENCE SIGN FOLIAGE BERMS OR PARKED VEHICLES BETWEEN THE HEIGHTS OF 24 INCHES AND 8FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVEL WAY IF NO CURB LINE EXISTS. REFER TO SECTION 6.12 OF THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL FOR ADDITIONAL DETAILS. 3. MULTIWAY STOP CONTROL WILL NOT BE USED AT ANY PUBLIC STREET INTERSECTION WITHOUT AN ENGINEERING STUDY TO PROVIDE DATA TO CITY OF RALEIGH TRANSPORTATION DIVISION THAT THE MULTIWAY STOP INSTALLATION WARRANTS CAN BE MET AND ORDINANCED BY CITY COUNCIL APPROVAL. 4. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 5. ALL DIMENSIONS SHOWN ON SITE PLAN ARE MEASURED TO FACE OF CURB UNLESS OTHERWISE NOTED. 6. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 7. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION AND TO THE SATISFACTION OF THE OWNER, BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 8. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 9. CONTRACTOR SHALL NOTIFY "NC811" 811 OR 1-800-632-4949 AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 10. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 11. PRIOR TO BEGINNING CONSTRUCTION BEYOND EROSION CONTROL MEASURES, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH PUBLIC WORKS DEPARTMENT (919) 996-2409, AND A REPRESENTATIVE OF THE ENGINEER AND OWNER. THE PURPOSE OF THIS MEETING IS TO REVIEW THE SPECIFIC COMPONENTS OF THE PLAN AND OPERATION OF THE FACILITIES DURING CONSTRUCTION. 12. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 13. ACCESSIBLE RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF RALEIGH UNIFIED DEVELOPMENT ORDINANCE (UDO) DETAILS. 14. ALL SIDEWALKS THAT CONNECT TO THE PUBLIC RIGHT-OF-WAY MUST BE ACCESSIBLE TO PERSONS WHO ARE BLIND, HAVE LOW VISION AND PEOPLE WITH MOBILITY DISABILITIES. PEDESTRIAN EXISTING ROUTES AND ALTERNATE PEDESTRIAN ROUTES DURING CONSTRUCTION WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 15. TYPICAL PAVEMENT SECTION DETAILS ARE SHOWN WITHIN THIS SET AND INTENDED TO BE A MINIMUM PAVEMENT SECTION REQUIREMENT. THE CURRENT GEOTECHNICAL REPORT SHALL OVER -RIDE ALL TYPICAL PAVEMENT SECTIONS SHOWN, IF THE GEOTECHNICAL ENGINEER DEEMS A HEAVIER SECTION IS REQUIRED. 16. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO SUBSTITUTION OF ALTERNATE EQUIPMENT. 17. IF UNFORESEEN CONDITIONS DEVELOP DURING CONSTRUCTION, REFER TO THE LATEST VERSION OF THE RALEIGH STREET DESIGN MANUAL AND CONTACT PUBLIC WORKS STAFF FOR FURTHER GUIDANCE. 18. ALL SIGNAGE ASSOCIATED WITH THE PUBLIC STREET SYSTEM SHALL ADHERE TO MUTCD STANDARDS AND SPECIFICATIONS. 1Nidth A Rtgtrt-of•waVwidth W6th center turn lane with median B 8ackof•eurlrtatiack-of•curh With center turn lane With medlan Stir�pe t 56detxa[k Imtnj 0 Planting area Iminj Tra wkway E Paralled parlung One. _ .-.. _ ...... ... . .......... ----- F Bike lane G Travel Iail e H Center lane Striped turn lane h1edlan General WaIkway type Planting type Tree spa cirtg ParkiRg type 90' 944 62' 66' 8' 6' 6' I1 11' 15' Sidewalk Tree grate f lawn 40" D.L. avg Parallel GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 5. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 7. CONTRACTOR SHALL DETERMINE LOCATIONS FOR SPILL CURB TO PROVIDE POSITIVE DRAINAGE TO STORM STRUCTURES THROUGHOUT THE SITE. NO "BIRDBATHS" SHALL BE CREATED WITHIN THE CURB AND GUTTER OR ASPHALT PAVED AREAS. STORM DRAINAGE NOTES 1. ALL STORM DRAINAGE PIPES SHOWN SHALL BE CLASS III REINFORCED CONCRETE (RCP) UNLESS NOTED OTHERWISE. 2. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH STANDARDS 3. ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4 ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 5. ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 6. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD, USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 7. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 8. MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE OR GEOTECH AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 9. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95 % OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 11. ALL CONCRETE PIPE AND PRECAST STORM STRUCTURES SHALL MEET NCDOT STANDARDS AND STAMPED ACCORDINGLY BY MANUFACTURER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL PIPE AND STRUCTURES FOR CRACKS OR BREAKS, PRIOR TO INSTALLATION. ANY DAMAGED ITEMS SHALL NOT BE INSTALLED. 13. "KNOCK -OUT" BOXES OR HDPE PIPE SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAYS UNLESS APPROVED IN WRITING BY CITY OF RALEIGH STORMWATER DEPARTMENT. RETAINING WALL NOTES 1. THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE TOP OF THE WALL. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING RETAINING WALLS ARE NOT LOCATED IN ANY STREAM BUFFERS, AND THEIR CONSTRUCTION DOES NOT ENCROACH INTO ANY ADJACENT PROPERTIES DUE TO ANY BATTER INCORPORATED IN THE DESIGN OF THE WALLS. 2. RETAINING WALLS ARE TO BE DESIGN -BUILD PROJECTS BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALLS. 3. RETAINING WALLS SHALL BE ASSUMED TO BE BACKFILLED WITH OFF -SITE BORROW MATERIAL OR PROCESSED FILL, UNLESS THE CONTRACTOR CAN PROVIDE TO THE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER, THAT READILY AVAILABLE ON -SITE SOILS CAN BE USED. 4. THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING OR ABOVE GRADE TO THE TOP OF THE CAP BLOCK COURSE SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. 5. ALL RETAINING WALLS OVER 30" HIGH SHALL HAVE A SAFETY FENCE (DESIGN BY OTHERS). 6. ANY PART OF ANY RETAINING WALL THAT EXTENDS INTO THE RIGHT-OF-WAY WILL REQUIRE AN ENCROACHMENT AGREEMENT. ENCROACHMENT AGREEMENTS FOR RETAINING WALLS SHALL BE APPROVED PRIOR TO CONSTRUCTION DRAWING APPROVAL. 7. ANY TIEBACK SYSTEMS FOR THE RETAINING WALLS SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAY. 8. STORMWATER RUN-OFF SHALL BE DIRECTED AWAY FROM RETAINING WALLS. ANY RUN-OFF FLOWING TO AND OVER A RETAINING WALL SHALL BE KEPT TO AN ABSOLUTE MINIMUM AND BROUGHT TO THE ATTENTION OF THE WALL DESIGNER PRIOR TO THEIR DESIGN. HILLSBOROUGH STREET AVENUE 3-LANE PARALLEL PARKING N.T.S. CITY OF RALEIGH PUBLIC UTILITIES STANDARD UTILITY NOTES (AS AP P LI CAB LEA 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS DETAILS & SPECIFICATIONS REFERENCE: CORPUD HANDBOOK CURRENT EDITION . 2. UTILITY SEPARATION REQUIREMENTS: a) A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. b) WHEN INSTALLING WATER &/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER & MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. c) WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. d) 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER & STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. e) MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN & RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER & RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS & A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (PER CORPUD DETAILS W-41 & S-49). f) ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS & SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL REUSE MAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER & SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. THIS INCLUDES ABANDONING TAP AT MAIN & REMOVAL OF SERVICE FROM ROW OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. INSTALL 3/4" COPPER* WATER SERVICES WITH METERS LOCATED AT ROW OR WITHIN A 2'X2' WATERLINE EASEMENT IMMEDIATELY ADJACENT. NOTE: IT IS THE APPLICANT'S RESPONSIBILITY TO PROPERLY SIZE THE WATER SERVICE FOR EACH CONNECTION TO PROVIDE ADEQUATE FLOW & PRESSURE. 8. INSTALL 4" PVC* SEWER SERVICES ® 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE & SPACED EVERY 75 LINEAR FEET MAXIMUM. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SANITARY SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0, ABOVE THE NEXT UPSTREAM MANHOLE. 10. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 11. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. 12. GREASE INTERCEPTOR / OIL WATER SEPARATOR SIZING CALCULATIONS & INSTALLATION SPECIFICATIONS SHALL BE APPROVED BY THE CORPUD FOG PROGRAM COORDINATOR PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTACT TIM BEASLEY AT (919) 250-7825 OR TIMOTHY.BEASLEY@RALEIGHNC.GOV FOR MORE INFORMATION. 13. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX-B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HARTLEY AT (919) 996-5923 OR JOANIE.HARTLEY®RALEIGHNC.GOV FOR MORE INFORMATION. ADDITIONAL UTILITY NOTES 1. ALL WATER MAINS, SERVICES AND FIRE SERVICES GREATER THAN 2" DIAMETER ARE TO BE DUCTILE IRON PIPE. 2" & SMALLER DOMESTIC SERVICES MUST BE TYPE K SOFT COPPER (WITHOUT FITTINGS) TO THE WATER METER. 2. ALL SEWER MAINS SHALL BE EITHER PVC OR DUCTILE IRON PIPE AS SHOWN ON THE PLANS. ALL PIPE MATERIAL SHALL MEET CITY OF RALEIGH STANDARDS AND SPECIFICATIONS AS DEFINED IN THE LATEST ISSUE OF THE PUBLIC UTILITIES HANDBOOK AND/OR UNIFIED DEVELOPMENT ORDINANCE (UDO). 3. ALL FIRE HYDRANTS ALONG PUBLIC R/W LINES SHALL HAVE A 3'Wx3'L CITY OF RALEIGH WATERLINE EASEMENT ONTO ADJACENT PROPERTY. 4. ALL SANITARY SEWER INTERCEPTOR LINES (12" AND LARGER), AS WELL AS MANHOLES AND FITTINGS ASSOCIATED WITH THE INTERCEPTOR LINE, SHALL BE INTERNALLY LINED WITH PROTECTO 401 OR APPROVED EQUAL TO PREVENT HYDROGEN SULFIDE CORROSION. SEE THE CURRENT CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT HANDBOOK FOR APPROVED COATINGS AND APPLICATION METHODS. 5. IN ACCORDANCE WITH GENERAL STATUTE 87-121(G), ALL UNDERGROUND UTILITIES INSTALLED AFTER OCTOBER 1, 2014 SHALL BE ELECTRONICALLY LOCATABLE. CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT FOR DETAILS AND SPECIFICATIONS FOR MEETING THESE REQUIREMENTS. 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL WATER AND SEWER MAINS WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE OWNED, OPERATED, AND MAINTAINED BY THE CITY OF RALEIGH. 8. ALL WATER AND SEWER MAINS NOT WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE PRIVATELY OWNED, OPERATED, AND MAINTAINED BY THE PROPERTY OWNER. 9. ALL UTILITY SLEEVES SHALL BE SCHEDULE 40 PVC AND INSTALLED WITH 2' MINIMUM COVER. BOTH ENDS SHALL BE CAPPED AND MARKED. WhM A Right-ot way width 64' 8 Back!oVcurh to back•of -curb 36' Streetmpe C Utility placement, easement (min) 5' D MainTenance strip (ruin) 2' E Sidewalk (min) 6' F Planting area (min} 6' Travelway G Bike lane 7' IN Travel lane III ALL TRAFFIC CONTROL/DETOUR PLANS AND _" PEDESTRIAN DETOUR PLANS TO BE PROVIDED BY Getwnd CONTRACTOR AND COORDINATED WITH THE CITY Walkway type . Sadewalk OF RALEIGH TRANSPORTATION STAFF Planting type Tree lawn Tree spacing„�� ,r_, 44' D.L. avg ALL CONSTRUCTION SHALL CONFORM WITH THE LATEST VERSION OF THE CITY OF RALEIGH AND NCDOT STANDARDS, SPECIFICATIONS AND DETAILS. BOYLAN AVE AVENUE 2-LANE UNDIVIDED N.T.S. C o o U ,� �cv � c OOb d �0 �0(n0 00 z GO vto Nato co I:a 6 fir^ VJ CAR ,, G 0 V-S" / 1109 �.. S �rto sip L/Z 00 W a cD W � � W Q Q � � 0�E-0 a�C/O > 1.4 w � O z N O W 5 � z U ww0 co F� 00 W '� AEU (vim UZ o z w x � � a W F-1 PROJECT NO. H TG-18010 FILENAME: HTG18010-N1 CHECKED BY: RSS DRAWN BY: JM S SCALE: N. T. S. DATE' 10-16-18 SHEET N0. C-2 x PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J MCADAMS EXISTING WATER SERVICES TO BE - - - - - - ABANDONED AT THE MAIN PER - - - - - - CIY OF RALEIGH STANDARDS. --� `@ E / / --w— w-EX- SSMH - - - RIM=360.94 8"VCP(E)=352.21 EXISTING 1 I-IILLSROROUG11 IT ST. (VARIABLE WIDTH PUBLIC R/W) / i DEMd AND REMOVE EXISTING VEGET90N, POWER,SIQN, CURB D GUTTER��$rT PARKIN PAINT STRIPIN CANOPY AND STAIRS N /F THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. PIN 1703-39-7175 DB 12630, PG 838 1.16 AC. ZONING: OX-7-UL EX. WALL TO BE REMOVED. CONTRACTOR TO CONSULT STRUCTURAL ENGINEER PRIOR TO REMOVAL DUE TO PROXIMITY OF EXISTING BULIDNG. N /F WILLIAMS- CROSS INVESTMENT CO INC 706 HILLSBOROUGH ST PIN 1703-39-9454 DB 1408, PG 569 0.67 AC. 7nnunl!_= nV--7-111 N /F SAMIH T & REBECCA A YEHIA RVCBLE TRUST THE YEHIA, SAMIH T TRUSTEE 704 W. MORGAN ST. PIN 1703-39-9004 DB 15864, PG. 676 0.12 AC. ZONING: NX-7-UL EXISTING WATER SERVICE TO BE ABANDONED AT THE MAIN PER rIV Y1C DA1 CIrIJ cTAKMADr)(Z N /F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7-UL EX. CB TOP=351.99 12"RCP(E)=349.47 EX. JB RIM=352.17 18"RCP(E)=349.34 DEWALK 12"RCP(W)=349.46 12"RCP(NW)=359.58 — — — — — no no � \ \ EX. CB \ \ TOP=352.96 EXISTING 12"RCP(E)=35\0.40 W. MORGAN ST. 1i (VARIABLE WIDTH PUBLIC R/W) I EX. SIDEWALK EX. SSMH I RIM=352.57 8"VCP(N)=344.38 IN /F N /F 8"VCP(S)=344.26 THE COLEMAN GROUP LLC I PLANNED PARENTHOOD OF GREATER EX. FIRE I 705 W MORGAN ST RALEIGH INC HYDRANT PIN 1703-38-8847 100 S BOYLAN AVE DB 15399, PG 1 I PIN 1703-38-9868 0.29 AC. DB 4798, PG 489 ZONING: OX-7-UL 0.47 AC. ZONING: OX-7-UL — N /F HILLSBOROUGH 630 LLC 630 HILLSBOROUGH STREET PIN 1703-49-1348 DB 16997, PG 1152 0.30 AC. ZONING: NX-7-UL ss sSEX. 8" Ss ss ss — — T -,-fXISTING STOPLIGHT POLE AMD LIGHT CONTROL BOARD TO REMAIN. CONTRACTOR TO COORDINATE CESSARY GRADE CHANGES WITH CI RALEIGH TRANSPORTATION. 3n 3 � _ 3n _ 3n 3n - S8703'40"E 238.51' EX. GAS LINE TO REMAIN -------I EX. FIBER LINES TO REMAIN. CONTRACTOR TO NOTIFY APPORPRIATE UTILITY COMPANY FOR RELOCATIONS IF NECESSARY. BLOCK 83 PROJECT P ZONING: DX-12—UG IiUNDER SEPARATE COVER (1 TRANS# 559068) I EX. VARIABLE WIDTH PUBLIC R/W I I / nwo no I /Z IIO __FO no F0 �d I 013 N /F �q CROCKER FAMILY PROPERTIES, LLC 615 W MORGAN ST III �I b �I !2 III I I PIN B 4 16759,PG1 885 D1165 0.63 AC. ZONING: DX-7-UL DEMOLITION LEGEND ��bJI L��'b111'4�L TREE OR OTHER VEGETATION TO BE REMOVED UNDERGROUND UTILITY TO BE REMOVED AREA TO BE REMOVED (SIDEWALK, CURB AND GUTTER, STRUCTURES, ASPHALT, CONCRETE PAVING, ETC.) NOTE: SEE PLAN FOR DETAILED DEMOLITION PROCEDURES, SEQUENCING AND SPECIFICATIONS. EXISTING SEWER SERVICES, IF FOUND, SHALL BE REMOVED ABANDONED AT THE MAIN PER CITY OF RALEIGH STANDARDS. EXISTING GAS LINES ARE PRESENT ON SITE. CONTRACTOR IS TO VERIFY LOCATIONS PRIOR TO ANY EXCAVATION CONSTRUCTION ACTIVITY TO MAINTAIN THE SAFEST ENVIRONMENT POSSIBLE. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. C o coCo rh U • o N 'd Q' p 1 �U d w v0 z• (n Q OUz I~O u� v`o Nato Co Ca � 0) C/) V N CAR •� 9 = �.. % S 0 0-4 w af� cc 00 W C\2 C\t 0� w W O > 1-4 w � O z N O F� W 5 z V ww Q M F� 00 A�� z C� 0 t � W V � O Uzi � 'Wk O 1-1 W W A !r � PROJECT N0. H TG-1 801 0 FILENAME: H TG 18 010 — D M 1 CHECKED BY: RSS DRAWN BY: J M S scALE: 1 „ = 20' DATE: 10-16 —18 SHEET N0. C-3 x PRELIMINARY DRAWING — NOT RELEASED FOR CONSTRUCTION TI MCADAMS N/F WILLIAMS- CROSS INVESTMENT CO INC _ _ N/F I 706 HILLSBOROUGH ST - PIN 1703-39-9454 —'L I I I HILLSBOROUGH 630 LLC DB 1408, PG 569 I I I I 630 HILLSBOROUGH STREET PIN 1703-49-1348 0.67 AC. - I DB 16997, PG 1152 ZONING: OX-7-UL L �I /� I— ----� O 0 - - �s____�_— II ZONI G30NXC mo7-UL HATCHING DENOTES =-1_-- — HEAVY DUTY DUTY ASPHALT FOR HARDSCAPE DETAILS SEE EXISTING PAVEMENT (TYP.) DETAIL ON SHEET D-2 (TYP.) EX. PAINT — — ----------- HILLSBOROUGH EX. PEDESTRIAN STOP BAR ST • CROSSWALK PAIN (TYP.) (VARIABLE WIDTH PUBLIC R/W) CITY OF RALEIGH STANDARD GRANITE CURB ALONG HILLSBOROUGH STREET. REUSE EX. GRANITE CURB IF POSSIBLE. TIE TO EXISTING STANDARD CURB AND GUTTER AND EXISTING ASPHALT (TYP.) TEMORARY — CONSTRUCTION EASMENT N/F THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. PIN 1703-39-7175 DB 12630, PG 838 1.16 AC. ZONING: OX-7-UL 0' OR 6' BUILDING SETBACK FROM SIDE LOT LINE I® I I I I I I � I I I •o. I I I =1 �l Li III II II I II I II I II I II I II I II I V VI\ V UVILVIIVV JLI Ul1V f\ I FROM SIDE LOT LINE N/F SAMIH T & REBECCA A YEHIA RVCBLE TRUST THE YEHIA, SAMIH T TRUSTEE 704 W. MORGAN ST. PIN 1703-39-9004 DB 15864, PG. 676 0.12 AC. ZONING: NX-7-UL EXISTING W. MORGAN ST. (VARIABLE WIDTH PUBLIC R/W) \— _ N/F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7-UL 6' WIDE PEDESTRIAN - CROSSWALKXTYP.) EXISTING POWER POLE AND STOPLIGHT CONTROLS ---------------------- - —— — — — — — — — — EX. SIDEWALK I N/F II THE COLEMAN GROUP LLC N/F I 705 W MORGAN ST PLANNED PARENTHOOD OF GREATER it I PIN 1703-38-8847 RALEIGH INC DB 15399, PG 1 I 100 S BOYLAN AVE I I II 0.29 AC. PIN 1703-38-9868 I ZONING: OX-7—UL DB 4798, PG 489 II I II 0.47 AC. I I ZONING: OX-7—UL SEE SHEET C-2 FOR ALL PROJECT, ALL CONSTRUCTION SHALL BE IN SITE, GRADING, STORM DRAINAGE AND ACCORDANCE WITH THE CURRENT CITY UTILITY NOTES OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS 15'R ACCESSIBLE \V RAMP S8703'40"E 238.51' FY PAINT FOR HARDSCAPE DETAILS SEE DETAIL ON SHEET D-2 (TYP.) CITY OF RALEIGH STANDARD GRANITE CURB ALONG HILLSBOROUGH STREET. REUSE EX. GRANITE CURB IF POSSIBLE. ZONING: DX-12-UG (UNDER SEPARATE COI 7 I' N8T45�3' 6' WIDE PEDESTRIAN CROSSWALK (TYP.) TIE TO EXISTING STANDARD CURB AND GUTTER AND EXISTING ASPHALT (TYP.) 1 6' WIDE PEDESTRIAN CROSSWALK (TYP.) N/F CROCKER FAMILY PROPERTIES, LLC 615 W MORGAN ST PIN 1703-48-1885 I DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL SITE LEGEND v SIGNAGE qL POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE RAMPS TYPE ® TYPE © TYPE PROPERTY LINE RIGHT-OF-WAY LINE EASEMENT LINE CENTERLINE ADA ACCESSIBLE ROUTE OPEN AMENITY AREA HEAVY DUTY ASPHALT PAVEMENT SITE DATA SITE ADDRESS: 701 HILLSBOROUGH ST & 709 HILLSBOROUGH ST PIN NUMBER: 1703490106 1703399107 DEED BOOK: DB 16937, PG 2509 DB 14313, PG 1726 ZONING(S): NX-7-UL (1703490106) + NX-7-UL-CU (1703399107) EX. ACREAGE: 0.43 + 0.39 = f0.82 PROP. R/W DEDICATION: t0.03 AC PROP. ACERAGE: t0.79 AC PROPOSED USE: GENERAL BUILDING: PARKING GARAGE/RETAIL TOTAL PROPOSED GROSS SF: 267,333 SF (8,472 RETAIL + 258,861 GARAGE) GENERAL DRIVEWAY NOTE 1. DRIVEWAYS MAY INTERSECT A STREET NO CLOSER THAN 50' FROM THE INTERSECTION OF 2 STREET RIGHTS -OF -WAY, NOT INCLUDING AN ALLEY. HC RAMPS: 1. ALL HC RAMPS TO BE FIELD ADJUSTED WITH INPUT FROM THE CITY OF RALEIGH FIELD INSPECTOR PRIOR TO INSTALLATION. 2. POWER POLES WHICH CONFLICT WITH FIELD LOCATED HC RAMPS ARE TO BE RELOCATED BY APPROPRIATE UTILITY COMPANY. OUTDOOR AMENITY AND PARKING REQUIRMENTS PARKING LIDO 7.1.2.0 - REQUIRED PARKING 1 SPACE/ 300 SF RETAIL RETAIL GROSS SF = 8,472 (ALL RETAIL) PARKING CALCULATION = (8,472)/300 = 29 SPACES TOTAL PARKING PROVIDED = 693 SPACES (14 HC SPACES & 13 COMPACT) ' BICYCLE PARKING RETAIL USES (MINIMUM 4) SHORT TERM (1 SPACE/8,000 SF) = (8,472)/5,000 = 1.7 SPACES LONG TERM (1 SPACE/0 SF) = 0 SPACES TOTAL REQUIRED = 4 SPACES BIKE PARKING PROVIDED (ON STREET) = 4 SPACES (2 RACKS) AMENITY AREA TOTAL SITE AREA: t0.79 AC = 34,257 SF. REQUIRED: 10.00% OF SITE = 0.079 AC = 3,426 SF TOTAL REQUIRED = 3,426 SF (0.079 AC) PROVIDED: OUTDOOR AMENITY AREAS: 3,426 SF (0.079 AC) = 10.0% 2 SEATING REQUIRED: 1 LF/50 SF OF AMENITY AREA = 3,426/50 = 68.6 LF SEATING PROVIDED: 70 LF 2 TREES REQUIRED: 1 TREE/1,000 SF = 3,426/1,000 = 3.43 TREES TREES PROVIDED: 4 TREES (SEE LANDSCAPE PLANS) 2 NOTES: 1. 693 PARKING SPACES PROVIDED BREAKDOWN: 240 - BLOCK 83 (SR-59-18 ; COR TRANS# 559068) 29 - TWO HILLSBOROUGH DECK RETAIL 424 - FUTURE USES 2. AMENITY AREA BREAKDOWN 1,306 SF PROVIDED ON SITE (27 LF SEATING & 2 TREES) 2,120 SF PROVIDED WITH BLOCK 83 PROJECT (SR-59-18 ; COR TRANS# 559068) (43 LF SEATING & 3 TREES) GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. CO O '4 U �r O co [� Co"p �i 'd dQ' U woo z• �04)o OUZ 00 u� �`O N co VJ V . N CAR r/C ' 09 z 0 5 W a W � C,2 Q � � a � 0 Z� w W O > 1-4 C40 W LO O z N 0 F� W 5 z U wwo M F� 00 W AEU z 0 z W !r � PROJECT NO. H TG-18010 FILENAME: HTG18010-S1 CHECKED BY: RSS DRAWN BY: JM S SCALE: 1 = 20' DATE' 10-16-18 SHEET N0. C-4 x PRELIMINARY DRAWING — NOT RELEASED FOR, CONSTRUCTION 'J MCADAMS N /F WILLIAMS- CROSS INVESTMENT CO INC 706 HILLSBOROUGH ST PIN 1703-39-9454 - - - - - - DB 1408, PG 569 - - - - - - 0.67 AC. - - - ZONING: OX-7-UL p E ---� w�w�w W-- EXISTING I_w�� ILL,S13O R O �lJ G H S �i ss _ ss ss \ p ss _ .. 9 - ss EX. 8" SS\ ST. ` UMITS OF (VARIABLE WIDTH PUBLIC R/W) DISTURBANCE (TYP.) ...". CITY OF RALEIGH STANDARD 1 GRANITE CURB ALONG 9 SAWCUT REMOVE AND 6 /. HILLSBOROUGH STREET. / REPLACE AS kEQUIRED FOR ._/ REUSEPOSSIBLE. CURB / I UTILITY RUTILITY IEMOVALAPDERECITY I PROP. Ary /BI DE IF N /F THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. PIN 1703-39-7175 DB 12630, PG 838 1.16 AC. ZONING: OX-7-UL TEMORARY \\ CONSTRUCTION \ EASMENT LIMITS OF ­-` DISTURBANCE (TYP.) -Tj I IJ 0' OR 6' BUILDING SETBACK FROM SIDE LOT LINE FROM SIDE LOT LINE N /F SAMIH T & REBECCA A YEHIA RVCBLE TRUST THE YEHIA, SAMIH T TRUSTEE 704 W. MORGAN ST. PIN 1703-39-9004 DB 15864, PG. 676 0.12 AC. ZONING: NX-7-UL N /F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7-UL - - - - I EX. SIDEWALK --� � � \ EX. CB \ TOP =35L.96 EXISTING \ 12"RCP(E)=350.40 W. MORGAN ST. (VARIABLE WIDTH PUBLIC R W)\ I EXLMH \ / / RIM�--352.57 / ;I��'VCP(N)=344.38 8"VCP(S)=344,26' = a _ - - - - - -- OU Ca I EX. SIDEWALK N /F THE COLEMAN GROUP LLC I N/F I 705 W MORGAN ST PLANNED PARENTHOOD OF GREATER PIN 1703-38-8847 RALEIGH INC DB 15399, PG 1 I 100 S BOYLAN AVE 0.29 AC. PIN 1703-38-9868 I ZONING: OX-7-UL DB 4798, PG 489 I 0.47 AC. ZONING: OX-7-UL N/F I HILLSBOROUGH 630 LLC 630 HILLSBOROUGH STREET PIN 1703-49-1348 DB 16997, PG 1152 0.30 AC. / ZONING: NX-7-UL E o- w � w� w w c- o- w w w- w ss -6- ss ss SEX. 8" SS ss-ss- SAWCUT REMOVE AND REPLACE AS REQUIRED FOR / ROADWAY IMPROVEMENTS PER CITY OF RALEIGH STANDARDS - - m - 1 LIMITS OF / DISTURBANCE / (TYP.) :�y 9 - 4c - - 3n 3 � _ an _ an 3n - BLOCK 83 PROJECT ZONING: DX-12-UG (UNDER SEPARATE COVER TRANS# 559068) SAWCUT REMOVE AND REPLACE AS REQUIRED FOR---- -- UTILITY TIE-INS AND EX UTILITY REMOVAL PER CITY OF RALEIGH STANDARDS EX. CB T/C=350.68 INV OUT(S)=346.68 CONVERT EX. CB TO COR STD CB EX. JB �� (ASSUMED LOCATION) RIM=352LL17 RIM- 50.40 / 18" RCP(E)=349.34 INV IN(N)=346.41 / 12" RCPXW)=349.46 INV OUT=346.41 / 12"RCP(NW)=359.58 o�-no_-L- /Zno no � 0013 I N /F CROCKER FAMILY MORGANERT ES, LLC ST PIN 1703-48-1885 III I I DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL GRADING LEGEND CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN O JUNCTION BOX ��-- DRAINAGE FLOW ARROW 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION STORM DRAINAGE STORM SERVICE LINE LD LD LIMITS OF DISTURBANCE 250 MAJOR CONTOUR 252 MINOR CONTOUR _______250 EXISTING MAJOR CONTOUR 252 EXISTING MINOR CONTOUR - - EASEMENT LINE SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. DISTURBED AREA = 1.00 AC. GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. CCo rh o • o Cq dQ' U w v0 z• 00 z 00 N Co Ca � Vd V CAc�R �i: •, �_' •� 9 = z 0 5 w ax cD W � � W Q O O > 1.4 w O z N 0 w 5 a V w Z Co 00A�� A W Z z W z z !r � PROJECT N0. H TG-1 801 0 FILENAME: HTG18010-G1 CHECKED BY: RSS DRAWN BY: J M S SCALE: 1 „ = 20' DATE: 10-16 -18 SHEET N0. C-5 x PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J MCADAMS EX. SSMH N/F RIM=360.94 WILLIAMS- CROSS INVESTMENT CO INC 8"VCP(E)=352.21 706 HILLSBOROUGH ST PIN 1703-39-9454 DB 1408, PG 569 0.67 AC. j( I ZONING: OX-7-UL Li II w — I �' I I 8"X8" H-304 STANLESS I I D— �_ M I SS i I STEELE SLEEVE i i w w�w�wc wD�o_ i -w cEX. GASGLINE EXISTING o 1 I I I Ex s" vcP I I w w w_=-�wc HILLSBOROUGH I LL S B O R O �LJ G H ST. I I I 8" FIRE PROTECTION i i - ss SS VARIABLE WIDTH PUBLIC R/W) I� X 8" VCP SS I LINE WITH RPZ IN I I I i ss EINTERIOR RISER ROOM I I j I SAWCUT REMOVE AND REPLACE AS I I j UTILITY TIE—INS REQUIRED EX FOR I I EX. SSMH i 1ITII ITY RFAAC)\/AI PFR r:ITY I I ry rioro nnTin i u.irc nnniToenTno I I RIM=355.14 —3n _ 8"X4" TEE TEMORARY CONSTRUCTION EASMENT FIRE WATERLINE BACKFLOW DEVICES WILL BE LOCATED IN THE BUILDING. COORDINATE WITH PLUMBING PLANS FOR MORE INFORMATION. BACKFLOW DEVICES SHALL BE A 8" WATTS LF909 (RP) OR APPROVED EQUIVALENT. DOMESTIC WATERLINE BACKFLOW DEVICES-' WILL BE LOCATED IN THE BUILDING. I COORDINATE WITH PLUMBING PLANS FOR I MORE INFORMATION. BACKFLOW DEVICES SHALL BE A 4" WATTS LF909 (RP) OR I APPROVED EQUIVALENT. II N/F I THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. I PIN 1703-39-7175 DB 12630, PG 838 I. 1.16 AC. ZONING: OX-7-UL l — Im I I I I I I I BUILDING BACK FROM SIDE LOT LINE I II EX. 1-STORY BRICK BUILDING EX. BUILDING OVER-1 PROPERTY LINE L EX. WALL 0' OR 6' BUILDING SETBACK FROM SIDE LOT LINE N/F SAMIH T & REBECCA A YEHIA RVCBLE TRUST THE YEHIA, SAMIH T TRUSTEE 704 W. MORGAN ST. PIN 1703-39-9004 DB 15864, PG. 676 0.12 AC. ZONING: NX-7-UL N/F 700 WEST MORGAN LLC PIN 1703-49-0004 DB 11755, PG 933 0.15 AC. ZONING: NX-7-UL --------------------- EXISTING \ wv W. MORGAN ST. � N /) (VARIABLE WIDTH PUBLIC R W \ I \ EX. SSMH RIM=352.57 I 8"VCP(N)=344.38 8"VCP(S)=344.26 ou EX. FIRE �\ HYDRANT 0 N/F HILLSBOROUGH 630 LLC 630 HILLSBOROUGH STREET PIN 1703-49-1348 DB 16997, PG 1152 EX. SSMH 0.30 AC. RIM=354.49 ZONING: NX-7-UL 8"DIP(E)=345.93 8"VCP(W)=346.95 — 0- -w�w w w w w Ss —f / EX 8" DIP SS se -SAWCUT REMOVE AND d, REPLACE AS REQUIRED FOR RC)AnWAY IMPRC)VFMFNTS I I z�;a" I jjl El II II I I x�Q� III I• I l I pgW III I •I L _ III III I� I • I III I II oI I m III N II I v . I I N I � m I it _ III I I " III I III I III I I II I 8" SS SERVICE \\ IL I I I I I EX. SSMH RIM=353.13 \ I 8"VCP(S)=346.01 I I r(T;4--- I H II FIRE HYDRANT III ASSEMBLY (TYP.) I FIREDEPARENT I CON ECT ON I I I III � I III I H III it I III I o I I II III _ SD SD SDI — EXISTING STOPLIGHT POLE AMD LIGHT CONTROL BOARD TO REMAIN. CONTRACTOR TO COORDINATE ANY NECESSARY GRADE CHANGES WITH CITY OF RALEIGH TRANSPORTATION. PROPOSED FIRE HYDRANT UNDER _ SEPERATE COVER an 3n 3n - -—S87*03140"E BLOCK 83 PROJECT ZONING: DX-12—UG (UNDER SEPARATE COVER TRANS# 559068) SAWCUT REMOVE AND REPLACE AS REQUIRED FOR UTILITY TIE-INS AND EX UTILITY REMOVAL PER CITY OF RALEIGH STANDARDS PROPOSED FIRE HYDRANT UNDER SEPERATE COVER LE N8T453' — —_ — = _ §6 -- SD -- �___ — _ EX. 8" CIP W/L (ASSUMED LOCATION) _w I --- --- --- --- c� 40 — — f10-- npFO old 1?0 — I N/F 40 THE COLEMAN GROUP LLC I N/F ^/ 705 W MORGAN ST PLANNED PARENTHOOD OF GREATER I PIN 1703-38-8847 RALEIGH INC II DB 15399, PG 1 I 100 S BOYLAN AVE I II 'I I CROCKER FAMILY PROPERTIES, LLC 0.29 AC. PIN 1703-38-9868 EX. FIRE I I ZONING: OX-7-UL DB , PG 489 HYDRANT 615 W MORGAN ST 0.47III II �� I IIII I PIN 1703-48-1885 ZONING: OX-7-UL DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL UTILITY LEGEND FIRE HYDRANT ASSEMBLY �•�' FIRE DEPARTMENT CONNECTION (FDC) 0 WATER METER N WATER VALVE N POST INDICATOR VALVE ® VALVE IN MANHOLE ❑ METER & VAULT © BACKFLOW PREVENTER REDUCER '-' PLUG 0-/+— BLOW -OFF ASSEMBLY e SANITARY SEWER MANHOLE • SEWER CLEAN -OUT m GREASE TRAP SEWER FLOW DIRECTION / ARROW YARD LIGHTS LIGHT POLE POWER POLE ti LINE BREAK SYMBOL WATERLINE • WATER SERVICE LINE ----------------- UTILITY SLEEVE SANITARY SEWER SEWER SERVICE LINE FM FM SEWER FORCE MAIN —G—G—G—G— GAS LINE OU OU OVERHEAD UTILITY UE UE UNDERGROUND ELECTRIC —T—T—T—T— TELEPHONE — — EASEMENT LINE SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. Co 0 � v • O t` C'ed,Nm � 00 C49 d�z z il go o� oLo 0) CID CV Co CD � A V i �N CARS,,/'.. � EA 09 z O Cn W a CD w I4 w A 1.4 A z O z z 14 W O z w O z E-" O W 5 z U wwo M F� 00 A (1) U w a z � z PROJECT NO. H TG-18010 FILENAME: HTG18010—U1 CHECKED BY: RSS DRAWN BY: iM S SCALE: 1 _ 20' DATE: 10-16-18 SHEET N0. C-6 x PRELIMINARY DRAWING — NOT RELEASED FOR, CONSTRUCTION IJ MCADAMS v c v L U L a� Q N In In 6; w 0 04 3 v J I O O oo N c 3 v 0 c c v (L a) in v c v v 0 0 O 0 In U U OL N/F WILLIAMS— CROSS INVESTMENT CO INC 706 HILLSBOROUGH ST =—� I N/F PLANT —SCHEDULE I HILLSBOROUGH 630 LLC — — — — DB 1408, PG 569 M I I I ' 630 HILLSBOROUGH STREET PIN 1703-39-9454 — — — _ — 0.67 AC. � I PIN 1703-49-1348 TREES CODE � I I DB 16997, PG 1152 — — - — — ZONING: OX-7—UL L J 44/r 0.� — — — QQ c — — — _ — II I� ZONING: 0NXC7—UL w— W—_q II PC 4 W w w w w Wow °� UE UE--`____ —_—_— -�—_#0 // \� ❑E UPE 5 �W-�W— --__— — — — O _ = EXISTING .� Ss ss_ss W w-----�—� _—� AB 2 w-la_W�W — \ w W WSW HILLSBOROUGH ��® � —ss ss ss ss TW�W�w SS W (VARIABLE WIDTH PUBLIC R/W) — 1< ss ss ss �;!� T ss ss — CONTRACOTR TO RELOCATE EXISTING E _ RI INFS IF P(1SSIRI F r.nNTRACTI)R IS TTl — L L TEMORARY CONSTRUCTION EASMENT N/F THE JUNIOR LEAGUE OF RALEIGH INC 711 HILLSBOROUGH ST. PIN 1703-39-7175 DB 12630, PG 838 1.16 AC. ZONING: OX-7—UL 0' OR 6' BUILDING SETBACk FROM SIDE LOT LINE lT EX. 1—STORY 1 BRICK BUILDING EX. BUILDING OVER PROPERTY LINE 0' OR 6' BUILDING SETBACK J ' FROM SIDE LOT LINE I I N/F I I ~ N SAMIH T & REBECCA A YEHIA RVCBLE 700 WEST MORGAN LLC TRUST THE YEHIA, SAMIH T TRUSTEE PIN 1703-49-0004 704 W. MORGAN ST. PIN 1703-39-9004 DB 11 0155 ACC. 933 ., . DB 15864, PG. 676 I ZONING: NX-7—UL 0.12 AC. ZONING: NX-7—UL I -- I __ — — — — — — — — — — — — — — — — — — — — — I� I � EXISTING W. ®IGAN ISM'. � (VARIABLE WIDTH PUBLIC R/W) ou--- --- _---W --W------�-s� I I N/F THE COLEMAN GROUP LLC I N/F I 705 W MORGAN ST PLANNED PARENTHOOD OF GREATER PIN 1703-38-8847 RALEIGH INC DB 15399, PG 1 I 100 S BOYLAN AVE 0.29 AC. PIN 1703-38-9868 I ZONING: OX-7—UL DB 4798, PG 489 I 0.47 AC. ZONING: OX-7—UL SEE SHEET C-2 FOR ALL PROJECT, ALL CONSTRUCTION SHALL BE IN SITE, GRADING, STORM DRAINAGE AND ACCORDANCE WITH THE CURRENT CITY UTILITY NOTES OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS 3n 3T1 3f1 _ II 3n 311 I— t(4,PC — III� ---- I I II rN mm II I� I I III I I rAM7ENITYAREA II INCLUDING LANDSCAPING I AND SEATING III I 1,306 SF II L 4'X ADA TREEB GR TE (TYP.) I'' I ii I I -j -1 • II Ia I I BLOCK 83 PRO CT III ZONING: DX-1 2 UG (UNDER SEPARA 0 R II i� I TRANS# 559 a II � I E_ I I � I I I I I II I II II I III I II I I I I III I III I H III it H III ' I I III I I I I II III I H III L__ — —_ SD SD SD — — —� — Sol' 110 no Flo 03 -®- �d I Iq N/F III II I CROCKER FAMILY PROPERTIES, LLC 615 W MORGAN ST PIN 1703-48-1885 III 11 ;2 III I I DB 16759, PG AC. 165 ZONING: DX-7—UL 3x ROOTBALL DIAMETER COMMON NAME BOTANICAL NAME LAL HGT REMARKS CHINEASE PISTACHE PISTACIA CHINENSIS 3" 10'-12' N/A EVERCLEAR ELM ULMUS PARVIFOLIA 3" 10'-12' N/A TRIDENT MAPLE ACER BUERGERIANUM 2" 8'-9' 25 GAL CONT./SINGLE STEM DO NOT PRUNE LEADER. PRUNE OR CUT ONLY DEAD DR UNHEALTHY BRANCHES '— PROVIDF STAKING IF SPECIFIED. IF STAKING IS PROVIDED, PROTECT TREE WITH BROAD STRAP OR FLEXIBLE TUBING. ALLOW FLEXIBILITY IN STRAPS TO DEVELOP TRUNK TAPER PROVIDE TURN BUCKLE AND WARNING FLAGS. REMOVE ALL STAKING AND ACCESSORIES WITHIN ONE YEAR FROM PLANTING. Jf— -HE ROOT FLARE SHALL BE PLANTED AT GRADE, / NO HIGHER THAN 2" ABOVE GRADE, AND NEVER BELOW GRADE. REMOVE EXCESS SOIL TO EXPOSE -HE RODT FLARE AT GRADE. TREE SHALL BE SET PLUMB MULCH OEFTH 3". KEEP MULCH 3" FROM ROOT l f FLARE AND DO NOT CONTACT STEM HIGH DUALITY SOIL MIX ASSPECIE ED WATER SAUCER, IF SPECTRE}, SHALL RISE N❑ MORE THAN X ABOVE GRADE. --COMPLETELY REMOVE TOP HALF OF BURLAP. LACING STRAPS, NAILS AND WIRE BASKET AND �j DISCAFID FROM HOLE. ALL SYNTHETIC BURLAP MUST BE REMOVED FROM SIDES OF ROUT BALL. — ROOT BAIL SHALL BE PLACED DIRECTLY ON COMPACTED SUBGRADE. HANDLE TREE BY THE ROOT BALL ONLY. NOTES' 1. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE DRAINAGE OF ALL PLANTING PITS, (POSITIVE DRAINAGE AWAY FROM PIT) 2. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 3. STREET TREES MUST BE 3" CALIPER AT INSTALLATION WITH A T MINIMUM FIRST BRANCH HEIGHT. 4. PLANTING SEASON OCTOBER - APRIL. 5, A TREE IMPACT PERMIT IS REQUIRED. fi ELECTRICAL OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE PLANTING AREA IMMEDIATELY SURROUNDING THE TREE. NOTE: SEE TREE PLANTING DETAIL n 11 S TIC -CFI I I III II SECTION CONTACT INFORMATION: C'TY OF RALEIGH PARKS. RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GOV WWWR4LEIGHNC.GOV MULCH 3' DEEP MAX. AND T MIN_ FROM THE BASF OF THE TREE SIDEWALK PAVING AND SUBBASE - - PLANTING SOIL MIX AS SPECIFIED 4• ❑IA. PVC PIPE WRAPPED IN FILTER FABRIC AND CONNECTEOTO STORM rt-111 .I =1 DRAINAGE SYSTEM WHERE APPLICABLE COMPACTED DR UNOISTURBED SUBGRADF NOTES: 1. A SITE SPECIFIC PLAN MUST BE DEVELOPED TO ENSUR7 THAT 1,1. EACH TREE IS PROVIDED A MIN. ROOT -ACCESSIBLE SOIL VOLUME OF 6W CUE IC FEET- 1 .2. THE TREE ROOT AREA BENEATH THE SIDEWALK IS EXPANDED TO MAXIMIZE ROOT ACCESSIBLE SOIL SPACE UNDER THE PAVEMENT. 1.S CONNECT 8011 SPACE FOR ROUT EXPANSION WHERE POSSIBL F TO AL LOW ROOT SYSTEMS OF TREES TO OVFRI AP AND COLONIZE A SHARED SOIL SPACE, 1.4. ANY COMBINATION OF STRUCTURAL SOILS, SOIL CONTAINMENT SYSTEM (e.g.. SILVA CELL), OR ROOT CHANNELING (e.g,. SOIL STRIP DRAINIAERATION SYSTEM ITH.AT FERFORMSAS SPECIFIED IS ACCEPTABLE 3 4V X 6' WIDTH MINIMUM APPI IFS TO BOTH STRUCTIJRAI SOIL S AND SUBS URFACF SOIL CONTAINMENT SYSTEMS. 4. SUBSURFACE APPLICATION SHALL 8E REVIEWED AND APPROVED BY CTfY OF RALEIGH PARKS, RECREA T ION AND CULTURAL RESOURCES URBAN FORESTRY DIVISION PRIOR TO INSTALLATION. STRUCTURAL SOIL SYSTEM CONTACT INFORMATION: CITY OF RALEIGH PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAN FORESTER: TREES@RALEIGHNC.GCV WWW,RALEIGHNC.GOV CITY OF RALEIGH WTAN DARD IZL'I AI L 6 wts Nu�d urnmacnee TREE PLANTING IN SIDEWALK WITHIN ROW TPP-07 —73 N' FRAME 72 114' FRAME GRAY IRON, RECTANGULARA'XW 1.5" MIN. THICK, WITH 114' OPENING OR LESS NOTES: I GRATE DESIGN MUST BE ADA COMPUANT. 2. GENERAL PATTERN DESIGN MUST BE AS SHOWN. 3. MEPTIONS OR PERSONALIZATION MUST SE REVIEWED AND APPROVED BY THE CITY OF RALEIGH. 4, A TREE IMPACT PERMIT IS REQUIRED. 5. ANERE TO STANDARDS IN THE 017v TREE MANUAL. 6. ELECTRIC OUTLETS AND OTHER UTILITIES ARE PROHI0ITED IN THE GRATE AREA CONTACT INFORMAT IOry CITY OF RALEIGO PARKS, RECREATION AND CULTURAL RESOURCES DEPARTMENT URBAA FORESTER:TREES@RALE IGH NC.GOV WAW.RALEIGHNGGOV 29 aF �I n ` '{rr•,JJf ���11��`' FRAMES ARE ASSEMBLED US! NOATXtIWX1A' } THICK ST=�L PLATE BOLTED SLOTS ARE All TO FRAME wl [23 3� 16UNC _ �9 1+7' X 1 STNLS STL. FLAT HD. )f WIDE MAX. m y�� CAc SCREWS BOLT TREE GRATE HALVES TOGETHER wl (2I 11743 )f Y STW. STL HEX BOLTS, GALV, FLAT WASHERS AND STNL STL. HEX NU7 1 tra 3 q" BOLTED PLATE (21318.1BUNC 4; 1G3ra3 TAPPED HOLES 1�" '� ASSEMBLY DETAIL 7 CITY OF RALEI' ;H NOTE ALL DIMENSIONS SHOWN ARE IN ENGLISH STANDARD DET.UL MATERIAL- CAST GRAY IRON ASTM A-48. CL ASS 3.5E pFyLS�rylg ��.,:,ng grrmr.�nrF FINISH NO PAINT WEIGHT: 208.515ET TREE GRAI E IN SIDEWALK WITHIN ROW TPP-06 GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. LANDSCAPE CALCULATIONS HILLSBOROUGH STREET STREET TREES HILLSBOROUGH STREET 193 LF LESS DRIVEWAY 31 LF TREES REQUIRED: 5 (1/40 LF) TREES PROVIDED: 5 BOYLAN AVENUE STREET TREES BOYLAN AVENUE: 196 LF LESS DRIVEWAY 51 LF TREES REQUIRED: 4 (1/40 LF) TREES PROVIDED: 4 AMENITY AREA AMENITY AREA BREAKDOWN 1,306 SF PROVIDED ON SITE TREES REQUIRED: 2 (1/1,000 SF) TREES PROVIDED: 2 2,120 SF PROVIDED WITH BLOCK 83 PROJECT (SR-59-18 ; COR TRANS# 559068) TREES REQUIRED: 3 (1/1,000 SF) TREES PROVIDED: 3 NOTES: 1. SEATING OPTIONS WILL BE PROVIDED ALONG BOYLAN STREET AND ON BLOACK 83 PROHJECT SITE. 2. NO TREES SHALL BE PLANTED WITHIN 10' OF A FIRE HYDRANT (AT MATURE GROWTH) 3. FINAL DESIGN OF AMENITY AREA LOCATIONS AND AMENITY ELEMENTS TO BE DETERMINED AT CONSTRUCTION DRAWINGS OUTDOOR AMENITY AREA CO O '4 U ICI • p N p � Q' 1 'd U d -moo z• rTi I � 0 �O 00 z ao N Co rn tl� V N CAR •�Q�� 9 = `'� �• • % S ,��/1111111\\,♦ z O i!1 W a w � u� C'2 Q � � a I 1.4 O Z� w 1w � O W O z N O F� W 5 z �3 M V w O M F� A 00 w '� A� I z w W � W w z !r � PROJECT N0. H TG-1 801 0 FILENAME: HTG18010—Sl CHECKED BY: RSS DRAWN BY: J M S SCALE: 1 „ = 20' DATE: 10-16 —18 SHEET N0. LS-1 PRELIMINARY DRAWING — NOT RELEASED FOR CONSTRUCTION 'J MCADAMS VARIABLE MOTH DEPENDENT ON GRASS STRIP WIDTH EXPANSION JOINT - CS ! � . M' I]�PANSION JOINT `!o,, 3.5' RADIUS MAXIMUM t 'EXPANSION !,!! JOINT' ' " �Ia- • r _ !.:'dP0.\Il 6" E]CPANS1dN JOINT - sLOPE 1I4"IFT (A ") SIOEWA� r 9" r 1k USE 6.5" WHEN DRIVEWAY IS USED IN LIEU OF A WHEELCHAIR RAMP TO ACCOMMODATE 12:1 MAXIMUM SLOPE (AOA COMPLIANT), SUCH AS IN A CUL-DE SAC. FULL DEPTH CUT SHALL BE MADE PERIPE SEE T-10.01.2 FOR ADDITIONAL NOTES PORTION TO iEMOVED GUTTER LINE J IF THE FINAL LIFT OF ASPHALT HAS BEEN INSTALLFID AND 15 DAMAGED DURING CURB REMOVAL. A ONE FOOT WIDE SECTION OF ASPHALT SHOULD BE SAWCUT AND REMOVED FOR FORMS TO BE USED TO KEEP A STRAIGHT EDGE ON THE DRIVEWAY APRON REINSTALL HOT MIX SURFACE ASPHALT PATCH $9.58. IF THE FINAL LIFT OF ASPHALT HAS NOT BEEN INSTALLED, THE ASPHALT IN FRONT OF THE APRON CAN REMAIN IN PLACE NO1JR5 CITY OF RALEIGH r. CURR AND GLITTER SECTION SHALL BE REMOVED IN ACCS]RDANCE W!T}{ DRryESVRY WIDTH APPROVED By THE CITY. ST&NDARD DETAIL 2 IF PERPENDkDULJsR CLIT t3 LESS T•IAN i' FROM NFXCT.JOINT THEN THE PARAU.EL MJ7 SHALL RF111SKNLS A4'6 O'1IIe NorTOSGi'-E BE MADE TOTHAT JO1Y' TANDARD Mt= THUS OF REMOVIN 3 1 HIS LIE IHCRJ 191901 ALU]'%:U IN NEW ROAU'NAYC1JNSfkDl'FtoN €]CI" I - CURB (FORA DRIVEWAY APRON INSTALLATION) T-10.24 L- PAY LIMITB FOR CURB RAMP SIDEWALK WIDTH B'W X T2•0 CONCRETE CURB 8' MIN T12' EXPANSION • • JOINT [TYPI BSWENALKWOTH MIN �- •za°TYP__ R•rlrraA DEPRESf.SiD 2'.e- S' ITYPI CURB & GUTTER a'MIIN - _ _ SURFACE {TvP �NING ,.. c7EP:TESSEC CONCRETE DEPTNI 12' E4PANS45N p•-S-CURB 5 GUTTER JOINT {I'YP1 [HEIGHT VARIES RAMP I FLARE 8- Clrf;B Rr_'VtnL DETERM1NEC LAINIO NG 4" NOTE • U5LSMALL FLARE ONLY WHEN A CURB 6Y FLARFE 3LOPEI W OL1L9 OR ECTL Y CONFL i T WITH APPROACHING VEHICLE TURNING MOVEMENTS TYPE N-3 �j 8,M% 112:1) MAX RAMP SLOPE 43 GROSS SLOPE; 2-430% C) (-.IJ RR RAMPS RFQ01RF A 14'4l") MINIMIIM IANDING WITH A MAXIMUM CROSS SLOPL AND LONGfFUDINAL SLOPE OF 2-00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS- SLOPE TO DRAIN TO CURB- C.) RAMPS AND DOMES SHALL BE INSTALrED THE SAME 4VIITTH AS THE $N7FWAi K d' MIN LANDING SIDEWALK AREA-, f I' DETECTABLE WRRNnuC - - "t - _- _� SURFACE(TYP) �- � �yx I1D.r, ' R' ITYP) A' MIN. CLJr7B 8 GUTTER CLJ R a GUTTER 11r Ei�AN510N `- DEPRESSED 2'I' JOIN] (TYPI CURB & GLITTER I•FEIGHT VARIES JRB REVEAL DETEPIAINED BY FLARE SLOPE) COMPETE DEPTH TYPE N-3A RAIAP 1 FLARE B' LANDING A" (COMMERCIAURETAIL USE) � I COT! sh'EFT 3 OF 8 Ei@iW9 ]NbNrt �, WV 4L9� u4aTT + _. VnMlsT�t4 �' LETTER R� �"nwmaw.. �-I SECTIONAA NOTES- 1- VO4EN A DRIVEWAY 15 TO BE CON5TRUC7ED VO4ERE FINAL LAYER 6 THE D1$TAPICE FROM THE END OF A STREET CURB RADLIa TO THE rj OF &V441-1 HAS BEEN PLACED, THE MIRE CAN BE SAW CUT IN A BGOINNINO OF THE DRIVEWAY RAPT US SWULD BE MINIMUM OF 20 FT STRAIGHT LINE AND REMOVED- IF THE FINAL LAYER HAS NOT BEEN PLACED, 7 CARD RADIUS TO BE DISSIPATED BETWEEN LIMITS NOTED ABOVE THE ENTIRE CURB AND GLITTER SHALL BE REWYED AND THE DRIVEWAY A '1' MIN- SC-INEEN DRIVEWAYS ON ADJACENT LOTS SHALL BE A MONOLII41C POUR USING 3XII PSI MAX 4• SLUMP CONCRETE 4V MIN. BETWEEN ORI VE4VAY5 ON SAME LOT. 0 F. EXPANSION MATERIAL SHALL EXTEND T?IE FULL DEPTH OF THE CONCRETE 9 NO RADIUS ENCROACHMENT SHALL HE ALLOWED ACROSS AN I rr EXPANSIDN ,JOINTS Ak.ONG 5113EWAUt SHALL BE LOCATOO AT NOT MORE THAN OAY NMOINM PROP, FRONTAGE- THIS IS DETERMINED EY EY,TENDI NG G INTERVALS & ❑[:MMY CON5TRTIC om JOINTS AT it INTERVALS nuMMY A LINE FROM THE PROPERTY CORNER PERPENDICULAR TO THE BAV to lh �+ JOINTS SHALL BEAT LEAST 113 THE SLAB THICKNESS iN DEPTH TO THE CURB AM UtMER LOCATION .j 3- SLOPE ON UNPAVED AREAS BETWEEN BACK GP CURB d SIDEWALK SHALL BE 114" PER FT. 16 ALL CONCRETE MUST BE POURED GN SAME DAY AS INSPECTION w r y 4. NO EXPOSED AGGREGATE OR OTHER SPECIAL SURFACE TREATMEN75 IN ROW OR REaHSPKIh ECTIS REOLIRED Iy�Iy..II ��Tff77 A. W rAMENBIGN AS SHOWN ON PLAN'AEW S*W L RE AS FOI. LOWS 1 t. DRIVEWAY RADIUS 5HA1.1. 9E A M:NIMUiA OF 9' FRGM ANY •�• rrI 18' MINI MLMA• iB' MA]BLILIM FOR RESIDENTIAL DRIVEWAYS CATCH HASN. aU W MAXIMUM FOR rOMMERCIAL DRIVEWAYS T Iu JOINT FlLLER 116" RADIUS (TYP I UQIF: MAINTAIN 50' MAX- BETWEEN EXPANSION JOI N TS OR AT ALL R IG I D OBJECTS N_ - - - _ _ _ _ - _ FRONT ELEVATION 112" TRANSVERSE EXPANSION JOINT V 24' B. . i• 3" a: a fA S garr•Tu' +� sLwe-Ir• E+ �.'r"".be''i�YivfddsZ.`u"SO'-"nD�.•J.Y.' 4• • •'errA"- - h 1. 3T CURB 8 GUTTER 1R 12• 2- 30° VALLLEY TYPE GUTTER 41 4" COMPACTED AJ3.0 UNDER STANDARD CURB 5 I MEDIAN CURB AND GUTTER c� A NO VALLEY CURB S:IW.L BE USED AT IN1ERISECIIONS, HYDRANTS. ETC. r e+- r` �aU MEDIAN CURB AND GUTTERJ�'Y +' {NON-MOUNTABLEI _ SPILL CURB DETAIL NOTES: 1 UY MAXIMUM BETWEEN DUMMY JOINTS, 13 MAXIMUM BETWEEN DUMMY JOINTS ON MACHINE TOURS. 2 712" "PANGION JOINT LIVERY 50. y yIJW FBI Cf3NC:HEIE MINIMUM, e" SLUMP MAXIMUM 4 LIOU16 MEMBRANE CURING COMPOUND SHA L MEET Tt RREQUIREWNTS OF SECTION 1926.3 Or NCDOT sir I OF2 STANDARDS & SPEC IL'ICATIONS FOR ROARS AND STRUCTlv:cs CITY OF RALEIGH 5. ALL CONSTRUCTION JOINTS SIIALL 3E FILLED ST4NDARD DETAIL W ITIt JOINT TILLER AND SEALER IN ACCORDANCE WlTi I NCDOT ROADWAY STANDARD DETAIL TNG.01 R1=WSKNLS 04TE O'Hra NO TJ SG4E THL JOINT MATERIAL SHALL CONFORM 70 SECTION 1172B-2 OF NCDOT STANDARD S SPEOLFICATIONS FOR CURS AND GLITTER TOADS AND STRUCTURES. 5. REFER TO NCDOT DETAIL 846-01 FOR CURB AND GUTTER SIJPFFIE LEVATIOH RATES T_ 10.2 6.1 (D 5' FAA - - _ PAY uMfFS FOR CURB RAMP 1fd' E)(PANSION JOINT CTYPI 1 I` - • _ _ I 0, (TYPI °� T - CROSS SLOM NOT To EXCEED 2% ON ANY 7 R=T' [TYPI PORTION OF RAMP OR DETECTABLE: N TRANSITION TO STREET - WARNING t12' JOINT ( SURFACE [TYPI JOINT TYP] cl ] SLOPE va MEET GRAZE. s5' MAmMUM `2)y � CFN75S SCOFF' 2.qq C/ PURR RAMPS RECAJ IRF A IV-T) MINIMUM IANDWG On I A MAXIMUM CFZCS,S SLOPE AND LONGITUDINAL SLOPE OF 2DM WHERE PEDESTRIANS PERFORM TURNING MANEUVERS, SLOF`E TO DRAIN TO CURB. RAMP5 AND DOMES SHAL. BE INSTALLED THE SAME W,DTH AS THE SIDElAfnl K C) IF LENGTH EXCr=- 5. TRUNCATED DORIES GI IALL BE INSTALLED ALONG THE BACK OF TI Ir CURD COVETING THE FULL WIDTH OF THE RAMP, 112" EXPANSION ' 3t J01NT(TYPI T. CONCRETEC CURB - �arpA, CROSS SLOPE NOT TO EXCFED 2%ONANY PORTION OF RAMP OR TRANSITION TO STREET, De.TGTAaLE 112" EXPANSION WARNING JOINT (TYP) SURFACE {TYPI CITY OF STANDAI TYPE N-4A I.�..IrM tiL1NC.kL I E !1tr I I I irNAP f l ANDING A• SxEETA OF8 DRIVEWAY GRADES EXISTING OR PROPOSED DRIVEWAY SIDEWALK PAVEMENT GUTTER LINE ySfiW, _ �ApRON r d• lit-lfeilE * 5' FOR SENSITIVE AREA AVENUE AND SENSi FIVE AREA AESIDEN i IAL STRE« i A. CURB & GUTTER, SIDEWALK SECTION VARIABLE B' 8' S 7"74.. MFNTWIOTH SHOULDERWIDTH 114'IFT PER FT ,2DSy6 1ORI11�111�11j�% 5 y B. SHOULDER SECTION NOTES: IF THE SLOPE BETNEEN THE TOP OF CURB AND GUTTER AND A POINT M F= FROM THE CURB AND GUTTER EXCEEDS 2n%. THIS SLOPE SHALL BE ADJ LISTED TO A MAXIMUM OF 8.33% 11'IFT I UP OR 4.171% f U2' IFT 1 DOVTN. FACE OF CURB AA es CC 21-M 21.6• 2'-6" 2'"6- PLAN VEIW TTW 1[t- 1 ate' I I �•�•' I I rr.' NOTES: TRANSITION NOT TO BE LOCATED WITHIN THE CURB RADIUS. •�I n....n r�.a-v VALLEY GUTTER T-10.26.2 ASPHALT PAVEMENT PATCH AND RCP PIPE BACKFILL SAW CUT SAW OUT AND TACK AND TACK FS[ISTINGPAVEMENT EXISTING PAVEMENT 1 NEW ASPHALT 3• MINIMUM R . q�aQ p�C7 n q49" aq'47D c] ° 93P ° 9 Co p r4gn4' Q'C]• ❑ �oo ,p p v�qa❑`, q ° °p . ✓ oo ° ° A :OQ❑Qaa ° cQ� 10 ❑ �C] Q 0-0 NEW ABC 12- MINI MUM 0EPFH " Q ° 0°° R O ❑ ❑ Q o / 9PSI Cr°9°n Op Gc4 O�n'.7 •o Qa°Qrti7°a Qn EX18 ING ABC t' i(EY-IN 1' KEY IN EXISTING ABC IIIIII--Ill EXISTING SUBGRADE COMPACTED FILL III I I II -I i I-i 11 III ;.I I�IIIII q�yQ��na SEE NOTE :t7 NOTES- 1. THE PAVEMENT EDGE SHALL BE DEFINE] BY A STRAIGHT EDGE FORMED BY A MACHINED SAW CUT. 2 THE TRENCH SUBGRADE MATERIAL SHALL BE BACKFILLE➢ WITH SUITABLE MATERIAL AND COMPACTED TC A DENSITY OF AT LEAST 95% OF THAT 09TAMED BY COMPACTING A SAMPLE_ OF THE MATERIAL IN ACCORDANCE WITH AASHFrO T-99 AS MOD IFFIED BY NCDOT 3 THE FINAL 1' OF FILL SHALL CONSIST OF ABC MATERIAL COMPACTED TU A DENS FFY EQUAL TO 100% OF THAT - OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE VATH AASHTO T.80 AS MODIFIED BY NCDOT, BITUMINOUS BASE OR BINDER MAY BE SUBSTITUTED IF APPROVED BY TRANSPORTATION DIRECTOR OR DESIGNEE # THE ENTIRE THICHNESSf VERTICAL L-DGE OF THE CUT SHALL BE TACKED 5- THE SAME DEPTH OF PAVEMENT MATERIAL WHfCH EXISTS SHALL SE REINSTALLED, BUT IN NO CASE SHALL THE ASPHALT BE LESS THAN 3"THICK. B. THE ASPHALT PAVEMENT MATERIAL SHALL RE INSTALLED AND COMPACTED 1 HOROUGHLY AND ROLLED WITH A SMOOTH 1)HUM ROLLER I ACHIEVE A SMLJUFH. LEVELHA7L:H - 7. FUR RCP 36" OR LAfK{ ER, #57 OR #97 WASHED STONE SHALL BE INSTALLED TO THE SPRING UNE BEFORE SAC KF ILL. CITY OF RALEIGH CITY OF RALEIGH STANDARD DETAIL STANDARD DETAIL uFcsy-ulA/g naTe a+re A17rrOsC44 RT7a'HJAE; re:rFryi�'e ADr�7 C2�F - DRIVEWAY GRADES ASPHALT PAVEMENT PATCH T-10.04 T-10.05 r PAY uM(TS FOR CURB RAMP AND DD� GTTER 17 EXPANSION I 01714l:RETB DEPTH JOINT ITYP) ff *w f F LARLy 6- LANCING 4' 5'MAX r r I 2 i 2'-e• Cu Re AND GUTTER ' IQ' EXPANSION JOFNT(TYP) 24' TYP a -.NON•WALIG SURFACE IN M A' MIN 12" MIN. S' ISIDEWALK . j TYPE R-1 t2':rOIJCRETE CDRB 1 fl33%112'1I MAX RAMP SL [WEOETEC-7AAHL[ WARNING �• L - - SURFACE C.=tRB RAPPDPE 2.07°4 g[ BITY/'�.iC '- � ��'•:_ CURB RAJr5P5 REQUIRE A iw{7" MINIMNlI LANOIVG A' MIN. WM I A MAXIMUM CROSS SLO MID LONGITUDINAL r - - SLOPE OF 3.ov% WHERE PEDESTRIANS PERFORM IQ EXPANSION ` - - -:•. TURNWC- MANEUVERS SLOPE 7O DRAIN TO CURB ANNT FIYP1 - r REAM AND DOMES SHALL BE INSTALLED THE SAME WI I7I H W3 I HE SRIENMLN SIDEWALK F of CURB AND GLITTER J� 1H LENGI H tnutEm S Y, I RUNL:AIED Dumps SMgLL BE INSTALLED ALONE THE SACK OF THE GARB +� COVERING THE rULL WIDTH OF THE RAMP TYPE R-2 • ; : • J f-HX]TiWALK SURFACE VSEONLY WHERE WATER WILL NrrC p47Ar1 w1T1-TIN L ANDINgI WARN a I-E 4 �' ' ' - - ... 6+ , IT CONCRETE CURB wrLRN1Nr, . . 3VWAGE B iTYPI�{''•. ... ... I' MIN TYPE R-2A 2-E CURBx GUTTER SIDEWALK LIT JOINTITYNTtTY ION P! sJj-NON•WALKSURFACE CONCRETE DEPTH \ _ - :1F••_ RAW I FLARES 6- SIDE'.WALK­ - _ -T I -EXPANSION LANDING 4' JOINT (TYPI F• . IT CONCRETE CLG$ DETECTABLE WARNING CITY OF RALEIGH suRFArE STANDARD DETAIL G ITYPi -- - _ - y(Wg . t/p: RIrN NOrT75g4'.E A' µIN. - TYPE R-2B JOINT {TYPI _ SIDEWALK CURB RAMPS (RETR❑FfTI r.G CURB AND GUTTER- NOWWALK SURFACE T-z0.o1.s NOTE SEE STANDARD DETAIL T-20 05 FOR PAVEMENT MARKING PLACEMENT >aoElvnL+ ;Ljy STpp1LAR s1DEwr,LK DETAIL SHOWING TYPICAL LOCATION OF SIDEWALK ACCESS RAMPS. PE DE$TR IAN CROSSWALKS AND STOP BARS, I fi S?OPBAR -❑HA'.... AREA PED-MINDl::L� VIVEWALR _ PF1�AI1lG VAVAJLE }l 5701 RAR IpCRWpL1L PFo AW'. � I r� =T-HAR x - cr:AssmAR>:A �� SIRE lf,LK r DETAIL SHOWING TYPICAL LDCAT ION OF SIDEWALK ACCESS RAMPS PEDESTRIAN CROSSWALKS AND STOP BARS FOR TEE INTERSECTION } I y.-ossw nl+L.t Urrl�svEv u4F¢I A iM•IFUJs CR HA[4l5 RETI1FiN AT RASP FOR RAMPS AT ASPHAI T TO ASPHAI T STREET TYPE DRIVEWAYS OR PRIVATE STREET TIE FN. Q�UFi+I'lL li CAMSS D AREA SNEETIOF8 CITY OF RALEIGH STANDARD DETAIL REV1;7IkLS 74TF: V40 rwrro SG4[E CURB RAMPS T-20.01.1 sw_a PAYUM(B FOR CURB RAMP SIDEWALK SIDEWALK Irt EXPANSION JOINT ITYF1 fi"Wr X 1Z'D CONCRETE CURB 6"W X T2'U CONCRETE CURB I TYP) - - CONCRETE DEPTH F T ZIPI SCE RAMPS 4r Duke A OUT7ER 1 CURB A GUrFF � A MIN LANDI%O b OPEKINI>'u R' 1rY JOINT TNT TSION YP} TYPE R-3 Cl�) 8.53% f 12T) MAX RAMPSLOPE. (pD. CROSS SLOPE 200% V CURB RAMr'S REQUIRE A L4'-a'I MINIMUM LANDING WITH A NA%MULK CROSS SLOPE AND LONGff1JDIKAL U OPF OF 2Rfl%VA4FRF FEDF%TRIAti PFRFDRM I UIMMU MANhUVEHS SLOPE I IJRAIN III 411HN. L� RAMPS ANO DOMES FHkL BE INSTALLED THE SAME WIDTH AS THE SIDEWALK 1 JOINTA�P1 SIDEWALK 5'W X 12'V CONCRETE Ci•IRS SUFdVALK q=1' ITYP1 I'•'W X TOT] CONCRETE C URR r l rd' E%P ANSION .IOWT ITYPI - -- tot, 70� DEPRESSED 7.8•-1 CURB & GUTTER - um DEl1ECTABLE WARNING- / �� Y�~-•..:'_ti 4 MIV SURFACE ITYPI DEPRESSEO T-$ GVR9 & GUTTER HEIGHT VARIES, leV05 REVEAL OETERMINED BY FLARE SLOPES CONCRETE DEPTH SIDE RAMPS 3" TYPE R-A s7aTB dFY I-ANDING A CUR. RAMPS IN' CITY OF RALEIGH STANDARD DETAIL. ►jEyMSy(�$ Li4!p: Rlrld 40r'TOEgY.E CURB RAMPS (RETROFfrI T-20.01.6 PAY uMfTS FOR CURB RAMP J 1!SIDN S�N•kn OINTN7(Tly'Pl s•wx 1rD {} _ CONCRETE CURB rrF } - _ CONCRETE DEPTH R-I, 2 RAMPIFLARE 8' 5' MAX. LANOFNG +" �• 17 O.ITYP+ � Y `y E7[�cEE4 7Ye DN ARYL +"Hew PORTION OF RAMP ORYSS R-1' Fry") TRANSITION 70 STREET. &'W %8•D 7YP. , . ' -4 - - 1 ^ERR Z'-uRFACE(TY?j .ryp) H2•EXPANSION .1WARNING JGNJT fTVP) JOINT (TYPI = 5 _ r;t. • _ TYPE N-1 (CURB TYPES Ii Q J A d ,15% { 12! 1 J MAX RAMP SLOPE CROSS SLOPE NOT YO CRC46'SLOPF_' 2 0CM _ __ _ __ _ - EXCEED 2% ON ANY 21•TYP WIDTH PORTION OF RAMP ✓ j CURB RAMPS RSOUIRE A le'•B•}MINIMUM LANDING 12• MIN WIDTH TRANSITION Tp SIRE WFTH A 16AxIMUM CRCLS 9Lf-1PE AN7 LC1HGIiUD[NAL� DETECTA9.E WARNING &LOPE OF s,ulA WHERE PEDESTFyAHS 7ERFORM 51NTFACE ITY✓'1 TURNING M A NEl1VER6. SLOPE TO DAMN TO CURS VIP' EX AIAS]CIN 0 RAMPS AND DOMES SHALL SE INSTALLER THE JOINT RYPI SAME WIDTH AS THE SIDEWALK IF LENGTH E ALONG 4DNI.TTRVk-1[ED DOMFfE SSP ALL TYPE N-1A (FLARE TYPE) URB COVERING THE FULL WIDTH OF THE RATJP NO TE: USE SMAL L FLARES ONLY WHEN A CURS TYPE U�A�C1T1NG VEHICULAR TURNING STALK -+ MOVEMENTS. 1R"EXpMsim _ 'JOINT ITYP). G - TYPE N-2 (RADIUS) 6"WxIrD - ^ BRR3.. •- a R-1'ITF'PE CONCRETE CIJR � _ • . _ _ Ut=TECTAIA.E WRRNINL= COAGRETE DEPTH CURBAGLITTER SURFACE frVP RAMP! F•I.PIFIE E IANT1BV13 4• 10 EAPANSiGN � Irr EXPANSION JO[MTFFYP JOINT jTYP) TYPE N-2 (TEE INTERSECTION) SIDEWALK �C ShEET2OF8 I1'mP) CITY OF RALEIGH �5ua {{LT TWARNfN6 ST.&NDARD DETAIL ' rr RFi160LS a4TE Rrfra rldrnscAf. CURB RAMPS 8' W X t7O rONCI`= CURB CU4SE GUTTEFf (NEW DEVELOPNIENTO T-20.01.2 ■ ■ c o co U ICI • O QFji U � L�'d co rh cq orb Q' U z • W I m C)z GO OUto v`�' Nato co Q � V � V ,,,\\\11111114j� nr N CAR •� I 9 = G ��•• S '���'�•��•••S. SUP..` ,1111111111\\\, O 0­4 cn W a NCO W Irv\\ W C\2 O O Z QI W 14 W � O z O W 5 z ww o co W F� ao �Z o A z Vf W a z PROJECT NO- H TG-1 801 0 FILENAME: HTG18010-D1 CHECKED BY: RSS DRAWN BY: i M S SCALE: N.T.S. DATE: 10-16 -18 SHEET N0. D-1 PRELIMINARY DRAWING e NOT RELEASED FOR CONSTRUCTION IJ MCADAMS TYPE µ1 IF1 A SR-1 TREE NEW STREET TREE (T EXISTING/PROPOSE[ 6" GRANITE CURB CROn SLOPE NO TO exCEEa xx GN 4Nr RURTIGN OF TO STR R TRANSI DON iCi siREE+ CROSS SLGPENO`T TD FI(L'.FFlyi. TW AN+ Pukl•al L'F IGIAW • FRTws,TW.4 To a� T WAL KftGG wI R VTffRNG13- wIURFACE IF 1IIa1PIyF ra eTni V7 Ec RRN► 91AIR SI()E WAN PLANTING OR OTHER haN- ■lALNING$L ftr Ate• IF CA•<TPVFv IE NOT PROTEGTED 91hEIWJ_ - ` vq= 9"4Y a IFDfCN[.RE7E C11R8 6 a PARALLEL CURB RAM!" STiP IF MT -APOUCU I GREATER TTLAN S 1N LT3lQrNQ. VTHERWSE PLACE DEiE.CfABLE V1y� WARNItr, QN THE EW ESURFACE a1E]EYYAI]C i-',YF 1r(t]CFdiE7iETp WItB �^P GFLLTTHRUUGH �Lq IT y1YY4 \ � r C,T1NriRTFTXYiE3 It CURS CURB RAMPS AT MEBIA1Y. ONg5 f FtAW RARE- ✓ _ - IIt_'ECTR3LE WARN INL'--- A-RNUNtI SURFACE SHALL EXTEND n3% - S1AITE: FULL WIDTH OF SIDEWALK. w,« UVID 11G OR NALIP _ LAW oS:9T.� " �O•grYr SHEET10F4 CITY OF RALEIGH. STANDARD DETAIL REWWAIT3 Rsrt•37.ra N7r.75CALE DETECTABLE WARNING SURFACE SURFACEPLACEMENT T-20.04.1 CONCRETE PAVER: I PER CITY OF CASTER PLAN ;ORED CONCRETE WING (TYP) PER CITY RALEIGH SPECS: kPITAL GRID SBF TREE GRATE D22 Series 0' -C 1 moo" �� SCORED CONCRETE PAVING PER CITY OF RALEIGH SPECS: 'CAPITAL GRID' CONCRETE PAVING PATERN N.T.S. RAMP WIDTH AREA VARIABLE 4' MINIMUM ■ • • • e • • e • ■ a e • • a Y ■ : o• s • . ■ v v • ■ ■ • a ■ a . m � s e a Ie e• a •• e s • • r • s ■ r ■r• • • • ■ r Y BASE MAMETER 0 4y R TO COT" R TOP DNMEIE'R OF NO LESS TFIAN 5[!%TO NO MORE THAN IGO% OF THE SASE DIAMETER UcB`Tq MIN a zr 2• - • _. S7iECAST CLASS •B` } 1 CONCRETE 1T DETECTABLE WARNING DOMES CONCRETE PAVER 4' HWN LANDING SLOPE i2.--1 MAX fe' MIN.I 114'IFT } 2' DETECTABLE DEPRESSED CURE I WARNING DORIES STANDARD 2•• 6• SEE NOTE 41 OURB d OiFiTER E XPIIN81[]N JOINT f • • T- GRCIJT Tq 5E78i gCKa 4• CONCR FOUNSY574PN FOR WARNING DOMES TO 5E WITH SAME POUR AS RAMP. FLARES. ETC. RAMP SECTION _ WITH DETCTA9LE WARN]NGPAVERS NOTES. 1. DE tLCTABLE WNW ING DOMES SHALL CUVEH 2'-V LENV T H AN FULL WIDTH OF THE RAMP FLUOR AS SHOWN ON DETAIL SIZE OF PAVER SHALL BE V X 1'. �. THE COLOR FOR THE DETECTABLE WARNING AREA SHALL 13E YELLOW FOR CONTRAST. SHEET2 OFd CITY OF R ,%LEIGH STANDARD DETAIL RF!4,TfLVC. ww a'+„s huT.75aff DETECTABLE WARNING SURFACE PAVERS T-20.04.2 RAN If1 - GRASSED PROPOSED SIDEWALK UTILITY STR1P (300D P.S.IJ P' I if4"7FT 114•IFT tl4YFT 11 iL I I IF C 5' - - - - - I - - - _ - - - Z-g' CURB ��--• COMPACrED TO A DENSITY AND GUTTEq OF NO LE55 THAN 959E a o�-, Sill o� TYPICAL SECTION � ❑ it 41 IOINr FILLER SIDEWALK SURFACE 25 -� PLAN VIEW TRAN5VERSE EXPANSION JOINT n 2 `C NOTES_ O 0 1 TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF 50 FEET P. ALL CONCRETE TO RE WDO PSI AND FINISHED WITH CORINO COMPOUND. a H 3. A B INCH DEPTH IS REOUIRE D AT LOCATIONS OF DRIVEWAY CROSSINGS. AT STREET INJTERSECTIONS THE LENGTH OF RADIUS CURB RETURNSj. (ALONG rr n AND IN THE HANDICAP RAMPS. � PROPOSED BITUMINOUS CONCRETE (FOLLOW CITY OF RALEIGH SPECIFICATIONS FOR PAVEMENT THICKNESS) FULL DEPTH SAWCUT EXISTING BITUMINOUS CONCRETE EXISTING AGGREGATE BASE COURSE EXISTING SUBBASE PERFORATED POLYETHYLENE - UNDERDRAIN WRAP W/ FILTER FABRIC IF REQUIRED BY GOVERNING MUNICIPALITY (TIE TO CLOSEST DOWN STREAM STORM DRAINAGE STRUCTURE) CITY OF RALEIGH STANDARD GRANITE CURB 6" 1 /2" 1 /2" EXPANSION JOINT `MATERIAL (TYP.) / � SIDEWALK 6" CLASS "A" " CONCRETE BACKING 3,000 PSI CONCRETE DRY MIX GRANITE CURB REPLACEMENT N.T.S. IA Min LANL•NGI SLOE 1$' IAAx [&A, LRR 1 2• w anE-,."Li= �RESSFDOl1Rs pnE - - AWNING F SEE NOTE P, EXISTING CQM"RETE 4•Yy STANDARD'- !Y '. [ 71R6 a CiUTrf3i _SECTION %1-A' OFTECThel.k• WARNPiNG $IJ CE Sv8TEl1 FOuN4AATIlN WFDI DET ECTAIiLE WARNING PAVERS Kls'. .+1 � • YEA cin.+�+ ix�r uiaAna.s1 •$mmrAaer�mmasmrsa,�®ea��®®asbae e®e®aaee®®3®e I. +arlYvrroeerao euveuee�re i+vv w9re qv oe�mNFFAp mfp oa�aww a4' iqG Ye a wsw�lBRm a rsea®AA@0P6 @09NFB@gS S@A@7e3 91t®®®De10®®a€ way®�PHeAe�s�®®oar # as mnrmiwowu®a lae4pee rra vlr >snvrnwwev RIP60 po@WW®6 BaA sa BlBW RA9we 1•PR Oi;aC ®69fiz&®�®S r6ii6i S'&Bi®SSG S er @ @Bb2®®JI�eS � rFl�fa�l9�YI e3 e+e rineaaFAeeF�U+An�sA� mow, e1Raa Aerwoa®®p,app nag T■sar00paw Il4'1I1 ,l;rIO FXPAN" ANCHOR I •4 • TILE INSTALLATION VIEW 9°%SC.Ni ■r n wL - ffiT_ R1O TE: ]41 bFG WJer THIS APPLICATION ONLY TO BE USES WHEN RE TRO VI MNG EX ISIING S BARRIER FREE RAMPS - sECiTON `m• T•'I.7Cfi SFSTION SHEETSOF4 CITY OF RALEIGH NOTES: STANDARD DETAIL 1 DETEG7A81 E WARNNG AGIAFSSFIAU_ l;7IVER Y-<I- LER ,TH AND Fill_L RFVrKm IuTF p.HIg NOT VLE WILTIH CF IreE HRAIR fLYJON AS'3HUYYk UTI 17tIAIL - 2. THE COLOR r0R THE DETECTABLE WARNING AREA SHALL HE DETECTABLE WARNING *R i M FOR CONTRAST SURFACE, SURFACE APPLIED IRETROFIT ONLY) T-20.04.3 PLAN VIEW CONCRETE PATH 0009 P-6.I. I i 14r SHOULDER V0FT 11d•hT SAW CUT .JOINT SPACING C :0' 0 C. T'-V SHOULDER 114'IfT COMPACTED TO A DENSITY ❑F NO LESS THAN 95% TYPICAL SECTION JOINT FILLER PATH SURFACE TRANSVERSE EXPANSION JOINT NOTES: i. TRANSVERSE EXPANSION JOINTS TO BE A MAX MUM OF 5D FEET APART. 2, ALL CONCR EFE TO 13E FINISHED WITH CURING COMPOUND. .3 A R INCH DEPTH IS RFOUIRFO 4. SAW CUTJOIWS EVERY 10 FEET OR SAME AS WIDTH. WHICHEVER IS LESS_ 5, NU UT U I SURFACE CUVENSIPLA I t:WMAN WXLS (,.. YYAILHLINE VALVEC]OVEHS, LTL; SHALL SE LUCAiEU WIIHIN PATH AND SHAD. BE MINIMUM I FOOT FROM THE EDGE OF PATI-I- u. ALL PATHS SHALL BE LOCATED MINIMUM 6 FEET FROM THE BACK OF CURB e PAULII USEFAIH WILIIH 10 HE:OIL It1(MiNEllBY CIIY01' WiALElc:fHBASED SH ON ROADWAY TYPE. LOCATON AND PEDESTRIAN VOLUMES. CITY OF RALEIGH STALSDARD DETAIL RES'7S±(!S5 r�c."'ON"CRFTF NOTMVLE MULTWURPOSE PATH T-30.02.2 RAMP SECTION WITH DETECTABLE WARMING SURFACE CASTAN-PLACE SYSTEM SLOPE 12:1 MAX (5'-4" MIN.) to MIN LANDING} DEPREssFI1cu�STANDAR [_,!_:IEL'IAII; WC,1EENOTE y y _ _ _ -• . • •� FIIPAN4i .10IN7 - CAS -IN -PEACE DETECTABLE WARNING SURFACE SYSTEM NOTES: 1. DETECTABLE •WARNING DOME$ SI LAA_L COVER 2'4r LENGTIi AND FULL 1M111'H CF 11HE RAMP FLUOR AS SKOWN ON DE PAIL 2. THE COLOR FOR THE DEFECTA6IE WARNING AREA SHALL BE YELLOW tOR CON FROI GALVANIZED STAKE REFER TO MANUFACTURER'S RECOMMENDATION FOR INSTALLATION ■ CITY OF RALEIGH STANDARD DETAIL Rf47a'rfASC'. rmr av Ia NI7Trasy DETECTABLE WARNING CAST-IN4'LACE T-20.04.4 ALUMINUM EDGE RESTRAINT BRICK OR CONCRETE PAVER 2 Wg' (54 MM) MIN. THICKNESS 1' TO 1 V2' (25 . 40 MM) COMPACTED BEDDING SAND n R■•C1 ••L•. L^p. •ye.� rr -Fl •aYi� • aY• •r�: Ew COMPACTED AGGREGATE BASE 4' (1 DO MM) MIN THICKNESS COMPACTED SOIL SUBGRADE CONCRETE CURB SET 114" (7 MMI) BELOW TOP OF PAVERS AND CONTROL JOINTS @ 15' (4.58 M) OC 6 r a� ••n, s•a a or �v:.Yv ao•a r�c� �. ed. SECTION 2 BRICK OR CONCRETE PAVER 2 318' (60 I■1M1 MON. THICKNESS °= 1" TO 1 T12" (25. 40 MMy �e c COMPACTED BEDDING SAND . q.6 04� COMPACTED AGGREGATE BASE 4' (100 MM) MIN. THICKNESS COMPACTED SOIL SUaGRADE NOTES_ 1. BRICK ON CONCRETE PAVERS ALLOWED ONLY UNDER SPECIAL CONDITIONS. 2. THICKNESS OF SASE MAY VARY WRTI SUBGRADB TRAFFIC CONDITIONS. 3. SCATTER SAND OR SCREENINGS OVER COMPLETE WORT{ AND SWEEP INTO CRACKS. 4. CONCRETE. PAVERS SHOULD CONFORM TO REDUfRENIEN TS OF AS TM C-1319. BRICK. PAVERS SI-10LAD CONFORM TO RERUIRFMFNTS OF A&T M C902-95 5. SEE CITY OF RALEIGH OUDES'ECTION 10-7001 IDj FOR L:UN.7TTILYIS UNDER WHICH C=oNGRETE 113R" PAVERS ARE ALLOWED, CITY OF RALEIGH STANDARD DETAIL Rf49SriA a ,.F U'wa ADT705,:4LE CONCRETFJBRICK PAVER SIDEWA X DETAIL T-30.03 CO o '4 U co I, AA l_ V cNd(m 9 cq 0 p I 'd Q' U v z • Q z 00 N co Q � I V ,,,,T1111111111j N CAR G 1109 �,,,,,,�a••.S..S\_ ,, ,111111111111,, )O V1 W a �O cc r l 1W � o o� O Z� w W �' O 1. W o z N O W 5 z wwo M F� 00 W '� V W z Vf W z !r � PROJECT No. H TG-18010 FILENAME: HTG18010-D1 CHECKED BY: RSS DRAWN BY: JM S SCALE: N. T. S. DATE: 10-16-18 SHEET NO. D-2 x PRELIMINARY DRAWING e NOT RELEASED FOR CONSTRUCTION TI MCADAMS FilllSt!EF' C ,rr_aD_ - 'C' V N.-: UNDI5TIJRPIFD ':. SOIL BACKFILL MINIMUM 51DF G JF 1/e7 STONE WHENIg' t0.:JF PIPE 60-- CL ARANCF ROCK DR W-A1 PR 15 } f F<0IJNTERED NOT E5: ! H - ! RENCtiFS REQUIRING 5 DPJNC AND BRACING. D1MiNS ONS SHA[ _ BE TAKEN FROM THE IN50F FACE OFTt1E 5110FING AND DRAGNG, 2. NO KOCF,5 OR LJ0;1LL)l K5 4' OK LARGE K 10 Bt U5tD IN HACKrILL- 3. Al I F3ACKFII I MATERIAI .51IN I LIE 5UCFA51 E NATIVE MATERIAI _ 4. MC"LL 5HALL Bt I AmKiA) IN G' Ul -15. 5. ACHIEVE 95% COMPACTION IN 5ACKFII I - Cif Of R.ALE IGH DEPARTMENT OF P1J511C IJTII ITIE.S KFNC,H T50TTOM DIMFN5ICIN5 s SAC:'4Pri I ING P, 01ARFMFNT5 FOR !?OC711.F_ IRON pWG- NO. R€VISON5 [ATE REVISIONS DATE W- 9-3-99 ABB 2-I5_05 RRH 3-31-m J.P.S, O 29- SAIz I IAFPING VALVE a - TOP VIPVV 30DO ?51 50LI1] CONCF•.t'1L 5HALL BE USED AS POUTING FOR DUCTILE IRON PIPE. VALVE N ANGF M.J- FITTING r} Q •' 9 4 ❑ a 'p �' P •en1 TAPPING 51EEVE 51DE VIEW NO 1 L5. 1 . CONCRETE 5HA'I NOT CONT,AG- DOLTS OK ENf75 OF MECI IAN[CAL JOINT "I IING5- 2. 5EF 5TANUARD REACTION BLOCK CI I OF P.ALLI6H TAT31 E5, W- r 0 .AND W- I I FC:R AREA OF DFrAFTMEN OF "J5LIC UTILJI1-5 CONCKLrt RtOT11RtD. 4" - 24" 5TANDARD TAPPING 5LEEVE AND VALVE A55EM13LY 7WG.. _ R€V1510N5 [A F REVISIONNS DATE W-14 I Y. -A. 12-3' 91 R.R.H 3-31 00 p_Jv.C. 9-7-99 1.P_5- �� ❑ � CA'iT DATE WATER �u A� PLAT. VIEW Manufacturer %, MO/DAY/YR Class 35 50T-1 D I A V1CW NOTE I "WAT,K LETTERING MUST BE I' RAI5ED (RFCt55fP FLU5H) 5tCT10N VIEW NOTE 2 - VALVE COVER SHALL BE DOMESTICALLY CAST, NOTF3 - COVER MUST HAVE A MINIMUM WEIGHT OF 25 POUND5- IiOTt 4 - COVER MU5T Bt CLA55 35 OR GRtATER MOTE 5 - C OVEK NfUST MEET OR EXCEED AA5HTO 11-20 I -DAD KEQUIP,EMEN15. PRDPERTY MINIMUM 36' HOR]ZONTAL CLEARANCE LINE FROM ANY OBJtCT FIRE HYDRANT, PUMPE`K NOZZLE TO BE POINTED TOWARD5 FIRE TRUCK ACCE55. TRAFFIC FLANGE BETWEEN 2' - G' ABOVE GRADE 5'DEWALK CURB AND G1JTTtP PAVE'„1ETJT j. M Y VALV± BOX n' GATE VALVE CONIC. THRJ5T COMPALILIJ 9ACt,fILL J LiLOCIi (TAMPED IN C' I I,- G• MIN, 3idANCH 1rl- P.E"TNN RAIIG CLANDV MAIN 1 -3"x -9% 4'T 11C:F: RESTRAINING GLAND 7 CU- F F. CRI-61-+tO - 5TONE MIN_ LINDI5TJJR,DED tARTH: dGTE5-- -'IRE HYDRANT 5YIALL BE A5 MANUFACTURED: MUEIIE:K. WEKtCAN DARLING. F.PN'NED'r- Mw. . WATER005 CLOY,', EAST JORDAN IRON WORr,5,OR J5 PFPE. Z. BRAkCH PIPE 5HALL BE DUCTILE IRON AW'NA C 15Q-3G r n ?'ALIT 5HALL BE ANAVA C500-5G OPEN LEFT -- -15 AND BOET5 511ALL BE 4' hat DIPPED GALVANIZED r-.= LLED I N TRUE VERTICAL 1`I5f ION IC T11E LENGTI+ FROM 111E VALVE To TOE 'AEC11ANK-AL Rf5TKAINING GLAND WFTI I A REBAR CAGE 51 IALL BE 1'. - - -- -- - - - -ROM IWJRANi AND r'DURED IN C0NCP.ETE. Y -:- -- - -- IN KW (X 11 F-' )r YASFMFN I AD. JAC.-NI I LJ KOW CITY Of RAL[ IGH 0EPARTMENT OF PI. J51 IC IJTII ITIES . = RANT AY 5TANDAKD FIKE HYDKANT INSTALLATION DETAIL WC:. fti W- 4- GAlt) 1AFPIN(;VALVL v ' ❑. _ ,p p • o o 0 4 p o a n - TOP VIEW 3000 I'51 501I1) CONCiftlL 5HALL BE USED AS POUTING FOR DUCTILE IRON PI Pt. VALVL N ANGF r} _ TAPPING 51EEVE 51DE VIEW NO I t5. I. CONC RETL 5HAI i NOT COTf+AGT DOLTS OF, ENf75 OF MECI IANICAL JOINT 1-11 1 I NG5 - 2. 5EF5TAN1JARD REACTION SLOG;. CI,Y OF FL-"GH TAT31 E5, W- r 0 .AND W- I I FCR AREA OF DFFAFTMETF OF �JBLIC UTILJIC5 CONCRtrt RtOT11RtD. 4" - 2.4" 5TANDARD TAPPING 5LEEVE AND VALVE A55EMSLY DWG. 'NO- REV15fON5 [a E I REVISIONS DATE W 14 Y.C-A- 12 3 51 KKH 3-31 00 p_VI.C. 9-1-99 1.P_5- -1-10 12"w. 1e, DOGHOU5E i _ N'OTE5: 1 j KEINFOKCLM ENT: -1 Q o' OCEW 2} CC) NCKOE: 4,DOC) P51 @ 28 QAY5 3) G^ OF #67 STONE 5MALL SE PLACED IN BOTTOM OF VAULT 4) METER FLANGE 511ALL BE i'LACfD 42 BELOW FINISHED GRADE TRAFFIC RAID ACCU-55 DOOR WI SLAM LOCK CA91 III MV I" MIN: 5• �-nr� ,LZZ4 32 NOZZLE5 W! 1rATICirIAL STAr,<DaR.S FHREALD5 r - 7-rNh IJ NOTES: I . RALEIGH PUHUC -T1L KANT5 5HALL BE PAINT ED 50LIU RED, 2- KNIGI TTDALE. * ROLE5VILJLff PUBLIC HYDRANTS 5HALL BE PAINTED RED W151LVER OPERATING N1JT5. F S. ZffiULOP PUBLIC RAMS 5HALL BE PAINTED RED ! SILVER BONNETS AND OPERATING � HYDRANTS w N LTT5. 4 WAKE FORt51 Atli] GAKNt-K, AND WrNI-)rLL MJbUC AND YRIVAIr- HYDICAN15 10 Lit - PAIN I ED 5AFE1Y YETI DW 4VrAI VEK CAl'5 AND OPERATING NIJT-j- b. OetKAIiNG NU 15 ON HYUKAN15 CON NLC: LIJ 10 VUbLIC MAINS LAKGLK IHAN 1 2" 5hALL SF PAINTFE7 BLACK- CITY OF FAJ 0611 DEPARTMENT Of PU131 IG 1I11I IT]E5 RAI EI ,I I- C,ARNER, KN10 FTDAI I- ROI E5VII I E, WAr,L I-ORt5T. WLNDtLL 4 nUILILON STANDARD FIRI= HYDRANT WITH 5" 5TOR2 PUMPER NOZZLE pWG. 'NO- R€V1510N5 DATE I REVISIONS I DATE W-5 ASB 7-2 1-05 1 i DRL 2-1 P-OB GATE VALvr _Ff 314" ALL -THREAD STEEL PLOD IGUT TO LPNGTtt) - 1 -01 M.J. NIPP1 E. WTrh GLANDS ,,N'I A .+ SEE W- 10 AND W- I VALVE MAY X [DLi'ED POP, REACT ION D! RECT I v TOTFf 13LOCKING CONCRETE AKEA ROD REQUIREMENT5 3 F• 2 £' 2 $• 4 121 4 i G.1 G 24• 6 30, 8 3G• a NOTC5: I : STEEL KOD5 AND BOLT5 5HALL BE 31¢• HOT DIPPED GALVANIZED. 2- 5FP STANDARD THRU5T BLOCK_ TABLES W 1 ❑ AND W I { +FOR CON CRPT 3_ CONC.RETE 01 IALL I NOT CONTACT T301T`3t OR ENDS OF MECI IANICAI FITTINGS_ 9. Ti 15 R.QDIliNG REQUIREMENT 001ff� NOT APPLY TO FIRE I IYURANT5. q Al fiRETER A55fMULv1 .z. 1 y d APPROPRIATE BACK? PR1rUFNT1D7J A_55EfN16LY o , oG {AT30VE GROUND ONLY) H .• V^ sL I • L DOMr5TIC LINE APPROPRIATF FIRE LINE BACKFLOW PRE- A55EM- (ABOW- GKOUNU ONLY] n L FIRE LINE MAIN I e IRRIGAAD e [ION LINE C. IF F AF'T•I IC:ABI E MLItK O KtUUCtD PRESURt A55ETRBLY W A55FMF3LY (ABOVE GROUND ONLY) I . 5FRVICF-1AP5 FOR 2" AND 5MALI-FF, POMF-5TIG 5E;,VIGF5 MAY BE BY CARPORATION COCKS. LARGER 5EKVICE5 WILL REQUIRE A TEE AND GATE VALVE OIL TAPPING 5LEEVE AND VALVE A55EMBLY AND 90' SEND_ 2. DOMF5TIC SERVICE TARS SHALL BE ALLOWED ONLY ON 6' OR LARGER FIRE LINE5 BEFORE THE 13ACKFLOW A55EMBLY. 5. 0NF DOME5TIG TAP F£!Z FIKE LINE ON 51FXT7 51DE OF BACKFLOW_ . 71KF LINE 5HALL HAVE A FIRE HYDRANT OR BLOW OFF A55EMBLY AT IT5 END TO FACILITATE FLUSHING WHEN NEEDED. 5. IRRIGATION METER 5HALL BE LOCATED ON THE 5I[F OF DOMESTIC METER WITH fNCREA5ING ADDRE55E5. G. THE 13AMPLOW 5HALL Bt INSTALLED NO MORE THAN 101 FROM THE MFTFK IN A V15113LF LOCATION. 7. DOME5TIC•ARRIGA7I0N BACKFLOW R15ERISTANDPi"E 5HALL BE OF COPPER OR BRA55. g, THE RP RELIEF VALVE 5HALL BE A MINIMUM Or 12" ABOVE ANY MATERIAL (MUI'C INCLUDED) OR GRADE. 9. A 5ERVICE VALVL 15 KEOUtZE6 AFTER IHt MI`iER BUT BEFORE THI` BACKPiAW A55tM51-Y FOR MAINTENANCE AND REPLACFMENT PURF05E.S. +0, THE IN5TALLATION MU5T 41-50 MEET ALL CODE RFQUIREMEtJ5 PFKTHETIC PLUMBING COUL, -� 1 9J 1 6" OPEf2AT15N NUT 2.!500" c 2 112" NATIONAL 5TANDARD OUTLET TI Rf-ADS C..1- DIFFAPTMENT QF PI. Jbi 11, IJTII ITIES HYDRANT OPERATING NUT AND 2 112" OUTLET Tt Kf-AD5 7WG. %0- REVISIONS DATE I RE091ON5 DATE W- RRH 3.31-00 15 G5 A.5'5 -13-n4 1 1-1-10 .r�P-l..p� •�_C'C? _ �F Frr':� r F a,1E SILLY NUf[' L' 7, 8' C MCRL-- T'XD REOf WLO 0% +Ul .A•ve5 Nn.r'•rrk�r ccwrerrr er3lxraur 1 I f. I .A a• � -1 .p SEE 5T AND AKD IW- f b A' AT 2' `Ok COVEK DETAILS ? d -A v 5TANDARD VALVE I - BOX TOP SECTION 10 I a 2'� f 6) SLIDE 5ECTION DOMESTIC CA5TlNG TINAL PAVEMENT COUR5E VALVE DDY +•� -a •!•!.'q • rQS+Eli 'i'}'. 9•'.1 CONCRETE PAD VAr VE BOk 1J5t 5" 5011. PIPE FOR EY"E%510N5 TAMPED �3p-Cf FIl I '. WATER VALVE n ❑ TRAIN 5TA5-IN C-I- OR D.I_ PIPE GA51tE1 TAMPED��: BACKPILL eL.r I i.:.V I'!C LA •M4.1'• •1 1tirj i1-,UN - --sR 5TANDARD VALVE 13OX / i3O 110h1 5i C I ION F 314' STEEL R❑D5 IT YP.] rQ 6t HAVE BLOCKEND5 TO NG ��HOT DIPPED GALVANizED HAVE BLOCKING `� i� GATE VALVE APPf';C7PTRIATE S Q NO FLANGE ON HOL115E 5ACKFLDW PREVEN11011 p l TLy SIRE, MIN 9" Of= PIP, IN5113E METER 15OX DEVICE GA1 t VALVt GATE VALVE C9 ❑ O �n y < n a FLANGED COUPLING ADAPTER iP NEEDED a m- CD ' KK 0 o FL.x FL.x FL.x TEE tJ y =+j METER AND T,F TO BF s n a INSTALLED BY CITY 2�� Z Fr3 NOTES: 1) DOMt5TIC MtitR5 ONLY T 0 2} ALL F17TING5 ARE TO HE MECHANICAL JOINT k. rn r 3) BRONZE STRAINERS 5+1ALL HAVF NoN•THRFADE1) � ❑ 7o BOLT HOLE5. • 'Hr TAT• 10 A, F'L'BLIG WAIN, }r11Y0 Tt,F F1.5•tT OF: WRY JCR D 7p"j� nit BPP i Pt)5iraL[ u]CAl10A15 \\ _r+owu_ BRONZE 5TRAINEIR ALL Bi=LI.. T] I. 901 BEND 5YPA55 TO BE KQV PR R TEE TO TEE FROM 5UPPLY LI NE SMALL BE 5AMt 51ZF AS SUPPt Y I-INE lk n rn ITrz n z TASTER OPENING 4• METER 1 28' a" METER 39" 6" METER m". PLAN V1 EW ❑e INgICRirNf 9IrTi(w P,r Uµ �i FIX- 0IJr51Rr•- ew�a5urrr i �Irr �I•- C7 +�L R-iL'l,u'kx, f R': -'1 I Ir!r-R •U a.y V-:N I. ALL ABOVE GROUND ENCLO5UKE PAU5T !LAVE ADEQUATE DRAINAGE (PMCP THE DIAMETER OF THE 5UP LY FIPF) TO DAYIIGMT ABOVE GRADE 2. RE.GIJCED PR,E5SURE BACKFLCW PRE5EMER5 MAY BE LOCATED IN A BUILDING PROV10ED THEKE ARP NO OTHER UN?ROTECTED TAPS BETWEEN THE MAIN AND TriE BUILOiNG- DRAINAGE IN A BUILDING Mt 5f BE TWICE Tilt DIAIVETtit OF THt 5111'PY PIPE, 3. ABOVE GROUND 1N5ULA7ED VAULTS MUST 5E A55E 1 Or.0 APPROVED ABOVE GROUND ENCL05URE5. 5EF CR055 CONNECTIQN MANUAL FOE=- FNCL05UKE FRgEm PROTECTION .AND CERTIFICA-TION RFQtiIREMENT5. +I. RE51DEr4TIAL LAW% IRRIGATION R.F. A55EM13LIE.5 THAT ARE REMOVFD TO PREVENT FREEZING IN I'Ht WINTtP, MONrH5 MU5F 5E CAPPED OFF AL A80Vf GkALIND A95EM151-IE5, ExCEPr RESIDENTIAL LAWN IRRIGATION A55EMBLIE5, MUST BE PROTFCTED FROM FRO57, 6. FOR ENCL05UEZE DIAAEN510N5 5FE DETAIL W-34. 7. STEEL RO05 AND 15009 5HALL BF 314' mO' DiPPF13 fvALVAnIX`fI- 6. ALL A55EME$UE5 MUST M ON rHF CURR`NT APPROVAL 1-15T. co 0 � v • O t` �Nm U A 0) 9 C4 0 04 d �0 00 �z0 o0 � oLo CV Q7 0)r^ V J � A V ,,�11111111//I" \A CARI-, 57 y• • �/ 09 J,= 10 •��•••S. SLP.� 'AA�1111111\\\, VL O_ NW aW (o 1.4 w A E-1 E-I r-1 1-4 A z a 00 - O z d' Z w W �' O 1.4 m O z W O z E-1 O W 5 z ww o M F� 00 �Il � � A uZ o x xz m fk V M�1 PROJECT N0. H TG-18010 FILENAME: HTG18010-D1 CHECKED BY: RSS DRAWN BY: iM S SCALE: N. T. S. DATE: 10-16 -18 SHEET N0. D-3 x PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION TI MCADAMS mW ASMr.ALT 5uRtf'AEE [k15T' JG FR'dESAEiJT 3 Mih1NnL1�h iiF-rr.1,` "'�i,M€ITT EXISTING UNDISTURBED SOIL COMPAC-ED FII I IN E" I IFfS _ PIPE RPPEF, T O 5A � 5-J NOTE5, I - IN NCDOT MAINTTNNED ROADWAYn CN1~ROACHME'7 PAOE MENT PATCH PZEQUIPFMLNT5 511ALL TAJ,F PRMEDrNCF 2. THI_ PAVI-Mrt-lF CLli 511A1 I 'r3E 17fflNrU DY A 5TRAIG111- fDrf AND CdF WI F11 AN APP ROl"RIATI` 5AWCUT MACH INI=. 3, TI-1E TRENCH 5ULGIRADE NAATMAL SHALL BE BACFFILLED WI TM 5UFFASLE MATERAL AND COMPACLED TO A DEN51TY OF AT LEAST 95 ;o Of THAT OBTAINED BY COMI ACF(NG A 5AMFLE OF THE MATERJAL IN ACCORDANCE WITH AA5rlTO T-99 A5 MpDLF1ED BY NCD0 T_ 4. THP f1NAL , OF FILL SHALL CON 515- CF ABC MATEFJAL COMPACTED Tp A DEN5FFY EQUAL TO I CO% Of THAT OBTAINED BY COMPAC`ING A 5.AMPLE OF -HE MATFRIAL IN ACCORDANCE WFTH AA511TO T_80 A5 MODIFIED BY NCDCr. 5. THE ENTIFt THICKNf55 AND VERTICAL > OGF Of CUT SHALL OF TRCKFD G- i Hf SAME D1=f-I d OF PAVEMENT VATERIAt WH1Crl EY15T5 5HAl I BE RffIAI5TAI IID. 13UT IN NO CASE 5Hf1LL THE A51711ALT BE LE55 THAN 3- THICK 7. 1 HE A5PHALT rAVEMENI MATEfRIAL SHALL 13E r.NSHALLED AND COMPACTED -1H0R LXGhLy WI I'l A 5MDOIri GKUM KCJLLfIR TO A0�,IFVl- A 5MO)IN LYVFL FAICh 5. REF€2K TO CITY OF RALEIGH .STANDARD5 FOR. TRENCI;E7 ARID PIPE BEDDING (5-4 4 5-5) FpR. ADDITIONAL DETAILS. 3. NO HAND PATCHING ALLOWED I C FAVEMfNT CUT_5 WITHIN NCDC7T +ROW 5rI&L r-CINFCRRJM �0 THE APPP 7VED ON 51 FE T-N(-.P[]ACi IMFNT FFRAMIT CITY Of RALFIGM ,ZrAK I MINE L;F I'Ut51 Its LJLII r FiPS 5TANDAKD A5PHALT PAVEMENT PATCH DLTAIL DWG- NO. REV15JON5 I DATE I F,LV 51ON5 I OATE 5 3 D-WC. 1 1 -1 -99 A-I3-0. 4-1 9-uii RRY 3-50-00 LP,5. I0-S-10 I- Tt1E TRACER WIRE SHALL BE CONTINUOUS TO THE GRf.ATE5T EmNT ros51BLC. WHERE .)O1NT5 ARE NfCE5SITATEU IN THE WlRF-. THE JOINTS SHALL. Of 5FGUREI-Y EkTEND TRACER WIRE 13ONDEO TOGETHFR MTH AN APRROVED INDU5TRIAL CIkJMF CONNECTOR TO TO JU5T BELOW PROVIDE r_FCTRICAL GONITINUITY. GRIM Pc 5HALL BE 51MILAR META4 CLEAN) OUT iLUS 2. THE CLEANIQUT AT THE RIGHT OF WAY AND OR EASEMENT 5HALL SERVE A5 THE TE5T FORT WITH THE TRACING WIRE 5FcOUGil T UP OUTjIDE THE CLEANOUT A55EMffLY AND WRAPPED AROUND TIHF 5TACK TWICE AT A T]FPTH OF APPP.Q7 im.ATCI-Y 12' BELOW GRADE. 3. SPLICED CONNECTION5 SHALL BE ALLOWED OtTWEEN THE VAIN UNETRACER WIRE AND THE LATFfiAL TRACER WiRP FIN15Hfr_I A, FOR NEW SEWER TA1'5 ON CYI5HNG MAIN5 vC11D OF ANY TKACFR WIRE. f'ROV10E AN ANODE FOR THE TRACING WIRE Tr NAllON AT THE f OINT Of THE NEW TAP ON -It Em5TING 5EWER VAIN. 4 -a LS LO p PAVEMENT CURD i-OOF TRACER WIRE ' TWICE AROUND CLEANOLTI ASSEMBLY MAIN TRACER WIRE FC]R NEW MAIN "" 5TING "Al N TRACER WIRE•NC- 2 GAUGF 5000 COPPFK rJ &Ikf WIRE IN ct RN15"ED GRADE =IP1�'• UNDI51UR15tD 501L 5 C r NITIA MINIMUM SIDE e #67 51-0":E C' D OF Pl'F r CLLARANCL WHEN R<C'Cti 15 ENC2L)N1TfRfD I O.D. OFF 1 " ��MAx1MlJlv1 51DE rL�ARANCF NOTES-: . TRENCHES REQUIRING 500RINlG AND BRACING, DIMEN51ONY5 SHALL BE TAKEN FROM THE IN51DE FACE OF THE SHORING AND 5RAONG. 2. NO ROC1L5 CK BOULDFR5 4" OR LARUR 10 BE 05f0 IN INITIAL 6ACICFILL. 3. ALL BACKFILL MATERIAL SHALL BF 5UITABLE N A7 IVP 'e.� LTF.IAL. 4 DACY71LL 5HALI SE TAMPED IN G' LIFT5 IN TPA-- ,- = 7 -- : 2' IN NON -TRAFFIC ARfArx 5. ACHifVr W% COME AC:I ION IN NON -I RAVHC: Ai: ' _ ,D% COMPACI ION IN I KArHG ARf-A5 6, IF IN EASEMENT 4" TOP50II , AND 17" Cl CAN 50 F'_- _ =.Y BE P.EOUIKED- 7. NO 13❑ULDFR5 5" IN DIAMETER, OR GCATE--. ALL - .AL 13A1-r-FILL. CITE OF RALEIGY DEPARTMENT OF PL1fil IC I1TII FTIE5 TRENCIH BOTTOM 01MENS,10N5 t DAGKf1LLING RfGU RFMFNTS FOR DIX.7f1.E IFON DWC:. NQ- REVISfONS I DATE I REVISIONS DATE D.W.C. 9-3-99 5 4 FRh 3-30-QO �.An1 IKUN UK bT',LTWIL CJ.PAN Qil PI JC, • - . - - '. .-. •� SEWER LATfRA1 NFW 5ERvICE ON Ek15TING MAIN- —rROvivE MAGNE5rUN ANODE (! LB MIN) REQUIRED WHEW£ NO TRACER WIRE 15 INSTALLED ON 5EWrR MAIN PAVEMENT OPTION 4' DIAMETER GDNGRFTE COLLAR G^ TMICK PLA50C GREEN MANHOLE MARKEF,-LAP> IEP - MANHOLE, 5EE NO TEST 5TATION OR TEST FORT- .SFANDARD H2O TRAFFIC LOAD RAT1=D I'ALVE BOX WI -1-1 LID LA3nffD 75' AND PAIN�E]D GREEN_ FLACED ABOVE LOOP 3 -T IMIN; DO'WN5TREAM 5F_WtK or WIRE INTO TEST 5TATIONi -- 1 , 57ANPARD INDUSTiJAL LASIVIP 15lM3LAR METAU-'tip1 2' MLT O NO. P GAUGE\� FI.+FD WFIH -50LILI SAYE I I I � CONCRETE I .or rFR FR,e,e_= R I I I f� %VIKE_ -'P I I SEWER I rPACf� I I I A Ftl2A1 WIRE AF:OLIND I I I I 5EE C'IRG _'MfFKIfN: E iOF I II II SArV'Ni rORTE 2 MANWHiF AND 571IC_F O ER %1WE FOR SADDLE ODEMSLNFR- MAI �-------- 1 FLOW j I lr ` L-----------------J SEWER J NOTE5- MAIN THE TRACER WIRE SHALL BE CONTINJOJ5 TO THE GREATFE5T E.KTENT 1,055151E. FOR GRAvrrY MAI N AND OR LATERAL IN5TALLATION5 LE55 THAN 8 F`, THE TRACING WIFE SHALL BE A�TACHED TO THE Ps-r TPACFR WIFE 5HAii- BF LAID FLAT ANIq 5YCURELY AFFP(ELT TO TirlF "IFf AT I D Foor INF.RvALS. Fr--' ^r MAIN AND OR LATERAL 1N5"ALLATION ❑EEF'ERTHAN 5 17, THE TRACING WIRE SHALL HE 1p1 AT A UEF`F++ OF 7-S FF. THE WIRE SHALL BE MO"EGrED FROM UAMAGE JURiNG THE Fr.= N OF T}iF 1V()Kn- NO BREAIC5 OF CIJT 5 IN THE TKAC.FK WfKF SHAI 1 13F PFKMrTFD VS- _ATERAL TAf'5 ARE MADE 15Y 5rPVICl! SADDLES- 111E TRACE♦'7, WIRE 511ALL NOT BE ALLOWED FC _ = LACED tltf JVEEN FHE 5AUULt ANli MAIN. N.A,- ITARKE�. SHALL DE PLACED ADJAGENT'TO MAN HOLE5 AT THFI DISCRE"rION QF OWN ER. OR OWNER' Rr] VE51_NFAFIVE. •�EF'r,cr IA7ERAL MATI<RIAL A5 RLOUIRED ,MLJ5T BE 2' BELOW GRADE WHEN 5EV&K CLEAN OUT 15 1N RAVE MrNl ORIMPERVICU 5 SURFACE, IT ML'51 R IN5TALLED rN51DE A VALVE 150Y (OK MINI.MANHCLP] WF r1 COVEK LABELED "51EWFR'. THE FULL LENGTH OF THE SFRVICE DITCH 5HALL , 5f COMPACTED IN 6' LIFTS WITH MECHANICAL TA P ALL TAPS WILL BE MADE U51NG MECHANICAL TAPPING r MACHINE. FOR PVC IN5TALLATION5, 5ADOLE AND BEND IQ MU5T SE 5EDD:D IN #G7 STONE. E FL)DdNG AND HAU-%GHiNG i OF PIPE 5ARKa MUST COMPLY WITH UO IRFJufENT5 OF A DETAILS 5-4 OR 5-5 ACCOIKDING TO PIPE MATERIAL- > 79 n LSI K IFF n 6",10❑K 12' TA?r'ING ❑ ? 5AI7DLE OR IN_LINE WYE I/I G' OR Na' BEND ❑ � ' c � 4S° 5�WER 70 Torn SADDLE EXISTING MAIN p095ADDLE IN51,LLLAIION OFT AlL5, 5t= 51ANDARJ DETAIL 5-31 t 5-32 1 PfPCE OF PIPE MIN, GRADE I % CAST IRON OR �RQN P C:LFAN OLrT FLOG IN5TALA,101V615Y UT ILIlY CONTRACT OR5 BEYOND THP PKOPERTY OR tA5LMENT LINE RPOUIRf A P1.UM[31NG UTILITY' PERMIT AND AKE •INSPECTED BY THE 'PLUM61NG IN5PEC T OR. DO NOT 5ACKFILL PRIOR TO I N5 P ECT I ON. •--4" D.I. OR PVC PIPE . - N BARREL OF PIPD E BE DID .O' f-EN51❑N (CLA55 II. III, OR IV) WITH PERMANENT \' PLUG CAP COMBINATION W1'f AND 1 r813FND (ONE PIECE) M p co � U ICI • O U �rNdcr) rh N oI?b dQ' U woo z• �0�o z Rio OU u� �`O N co Q � VJ V N CAR G 009 S SOP ,��r 1111111\J,, L/Z O cn W a cD W � W Q E-I w W �' O > 1.4 �CD w LO O z N O I W 5 z � Mo m 00W�� A V z O W z V I�1 W z 5� !r � PROJECT No. H TG-18010 ETLENAME: HTG18010-D1 CHECKED BY: RSS DRAWN BY: JM S SCALE: N.T.S. DATE: 10-16-18 SHEET N0. D-4 x PRELIMINARY DRAWING — NOT RELEASED FOR CONSTRUCTION TI MCADAMS f2) DROP MRNPLE1 N8' i, 9nn4 r�8nm1 +h t✓P• — —rLY• iSaNnm1 IS�nrnl i b.l• USE EAST JORDAN IRON WORKS, INC. V-4096.2 OR APPROVED EQUAL ya" room, P v 0 C3 m C+7 d v 6 TOP OF [:UI+S NOTES' 1, THE SLOPE OF THE GUTTER TO THE CATCH BASIN ON THE UPHILL • ■ I� IN «sr� rrrrls rr� lao�l A SIDE SHALL BEGIN I0FROM THE THE CATCH BASIN. THE SLOPE OF THE GUTTER TC THE CATCH BASIN ON THE DOWNHILL SIDE, SMALL BEGIN 1Tr FROM THE CATCH BASIN. 2. STEPS SHALL BEINSTALLEDIN ALL CATCH BASINS OVER 3' IN DEPTH, DEPTH SHALL BE MEASURED FROM THE TOP OF CURB TO THE JNVE FIT OF THE CATCH 3ABIN. & SOU13 OONCRETE BRICKS MAY BE USED IN 4X02 OR 4XSX19 SIZES, 4- NCDOT APPROVED PRECAST CONCRETE BOXES ACCEPTABLE USING STANDARD T CASTINGS- 5. DOMESTIC CASTING REOUIRED WITHIN SIRLE P RIGHT OF WAY- S 1" MAXIMUM EXTENSION OF PIPE INTD THE STORM BI77( / - • -_ E'UPT812113EEP a • B �` 12 ovtH 12 nE� fie, n6r STANDARD C.B. STEP 2-43 REBARS ,q F LONG 5' — 3 T GROUT '�-IN PLACE '➢ r us �N'sa 000 ❑OO A s+eE ��ty PLAN ELEVATION YOnE t.'.Ey pW TOh OF CB 1'{� iuE �E91FiRt♦-ClS�5T3 G A.YIWIM. 3.BNM1. r ..xf REMSTNr m' •r C)FEP TFRiu Yuw�°ern a' PROD T m IX m I��� ml lGnq .,''�. I ELEVATION SLCnON AA vmr naN rr °rF".rumnc s Tp FYSEIIO Q I i�fi liil -',. Nui1 Wf CITY OF RILEIGH STANDARD D£T•U1. •4e�a•no - r^�I REVfSKNLS *J,'�F-aTHa yor R75L'hE `3000 PSI CONCRETE T OM CATCH BASIN sw-10.01 jM,• ibm)LErrEKmG M7 iiimml LETTP41A3 IkAl96llf �\ {RAI8604 CITY OF RALEIGH /111 f 3�rLSNIm, a3mn3xrllp W D W9RSU piN MING' NO I RAi IN IV S]!llIJO � 01 SNWHtl mAiNE TO FP� °EsM 1mn9vp 3tl,1 Ot, i94Lk,lnu Ok 4Eu£F RiYFR , _ NEI E H013IVb 101.i10 y{ lf2' 18a4mml COVER SECTION ASSEMBLY SECTION 11 fir I19ammt t t:w {i9mm1 I' L°Fnmf l 'q j % NA7AY[ITW MOVA'O R X 74j _jV] 131 T!V-%3 3141 LG HEX HD BOLTS. NUTS KiWr 9I WITH LOCK WASHERS BACK SIDE OF ASSEMBLY NOTE USE GRADE B BOLTS ONLY FOR BOLTING TWETHER NO.d REAAR Y O.0 PLACEO 3' FROM GROUT FRAME L=F, ALL SIDES. TO 'LAB TOP ' 'I` NOIES- L �III ` 1. FOR 24• PIPE x LARGER USE Irrl�+il,lful� rl III+ �lil� III PIPE pIAMEfER PLUS IrFOR ^ AwU81 1O 10P -+�'o r •- . _ 'A CONCFiETS .... • Illl� ° MINIMUM INSIDE DIMENSION OF BRICK 2, USE 4"X4'K8. OR e X II"X 151 ?. SOLID CONCRETE BLOCK. CAST ,rr PLASTER T AIRY CONCRETE T PLACE DR PRECASTSTANDARDS TO MEET STANDARDS 31 MAX F BLE ACCEPTABLE R" MINNUM. OVER V OEEP � + To 5 POLE 3. FOR STEP REOUI REMENTS, FROM•��0UP •• •� a SEE NOTE 4 ON STANDARD � R' > DETPJLSWttlAS. 3Ga0 PEI CONCRETE " •a; ➢ - ��II Ky. � ,,,r,.. ��II CONCRETE SLAB TOP P XR5 -A" GORERETF � I I I — I IRIPROONIV� N!- 7p3' ilawnl rE 1'P" IF3mml I N+' f+"mml NO.3 R£9AR 3- O.C. PLACED 31 MOM EDGE. ALL SIDES CITY OF RALEIGH STANDARD DETAIL REVfw+ONS 7,7E-0•rHa NOTR15 u STANDARD J IINCTTON BOX SW-10.04 sY s4Y Z y ' �..5. ys•t i�� � aF y •-rr�v� tic�� �:•?:: � � .s• - . .��.K= � s•�+ r r10Cmml USE EAST JORDAN IRON WORKS, INC. }__ V-4091r2 T OR APPROVED EQUAL 14.-j [11? m1 COVER SECTION 1904mm, A— t7 ,1 1' i1Am I -I I� it mmI ASSEMBLY SECTION lL LA,FYfLnfl L+OrJRY/YRt T317W-9x3314' LO HEX HD SACK SIDE OF ASSEMBLY BOLTS, NUTS {GRADE e1 NOTE VNTH LOCK WASHERS LL9E GRADE B BOLTS ONLY FOR BOLTING TOGETHER TYPICAL MH FOR STORM SEWER PIPE SIZE MH DIAMETER 12-24' 4'-O" 30.42' 5'-0• +6• a,-tr 541 6'-0• B STANDARD MANHOLE A — RING .AND COVER f a w t 5-0 1 -t on ° es § OHHL oraGPE , C _ C U'THICK UP TO 12 DEEP lYTHIpCrnERIZDEEP o LOPE WW1--, 30130 M raNr,RETE— A GROAT SECTION A -A SECTION B-B R TYPE A SECTION C-C rt M t M DETAIL OF pbl PLATES Rtl I Cir L/ATFQfAI NOTES_ 1 DEPTH MEASURED FROM TOP OF CASTING TO INVERT OF MANHOLE 2. PRECAST MANHOLE COMPONENTS SHALL MEET ASTNI-C-478 REQUIREMENTS, 3 SEE STANDARD SW-10 10 FOR MANHOLE COVER DETAIL. A 4.. 00MESTIC CASTINGS REOU19ED WITHIN STREET RIGHT-OF-WAY. CITY OF RALEIGH STANDARD DETAIL REMKM l STANDARD CLASS "A' MANHOLE sw-10.0s 10 GSTAINLESS STEEL DROP HANDLES pal c F � m pat Cal NOTES: PAINT WITH RUST INH18ITING BLACK PAINT_ MATERNAL LIST FOR ONE UNIT - MAKE f 1 UNITS 1 Cl5 X 3&9# CHANNEL 82 112" MK-wl 4 118-X VRP, FLAT BAR -3- MK. I 2 3Wx3"H.R.FLAT BAR 10" MK"phl 2 112" STAINLESS STEEL ROUND ROD 15" 4 S 112" STAINLESS STEEL HEX NUTS 112" STAINLESS STEEL FLAT WASI IERS CITY OF RALEIGH STAN.Dio D DE feUL RF111SKJILS 7+'F OrHa nwriasG+[E CTEELTO N STEEL TOP SW-10.07 A W4• HOLES FOR HANDLES E DETAIL- 1 5•-a• L SIDE ELEVATION i TREAD/SURFACE r A 15" PLAN OF COVER B J SE"ON.A A 1 �1"�S+-I�� �� • � T 11A- SECTION B-B TOP VIEW am ROl1Nn II 1: k a• M1' GNU. 11rI NUT V y 3!8' 1pryC s } 31A" 41l2- DETAIL OF HANDLE �. 2T 114'�� SIDE ELEVATION r 1r2^�1 Ft �� H�1 lyd" S1IEIGT T OF CITY OF RILEIGH A J_ STANDARD D£T•AIL Rt=VISxJALS a+�orna �uorrosGu.e CATCH BASIN END ELEVATION CASTINGS sw-10.06.1 I ' c� Q0 D SPA � COVER 120 LBS. MINIMUM 25 TAIV I y" -231111$"� I BUTYL-NEK OR APPROVED SEALANT 7 Ur �• BETWEEN FRAME AND COVER 33114, r Sf8•K3" LAGSHIELO IN HOLE DRILLED INTO CONE OR RING WITH ANCHOR SUNK TO NOTES: DESIGN DEPT}l, AND 518 Y,3' 1, ALL MANHOLE FRAMES SHALL BE DOMESTICALLY CAST- HOT DIPPED GALVANIZED LAG BOLT AND WASHER 2. FRAME SHALL BE A L9I NIMUh1 WE lr FHT OF 1{2 LB ; WFTI41M PUBLIC kOW AND IWJ LBS. LNI IMIN EASEMENTS- 3. COVCR SHALL WEI CFI A MINIMUM OF T20 �-BS_ 4- ALL MANHOLE FRAMES OUTSIDE OF PAVED SUfiFACE SHALL BE CITY OF RALEIGH R31.717.0 TO THE CON SFCTION OR RING WITH A MINIMUM STANDARD D£TeUL OF 4 BOLTS PER FH-UWE RPWSK*a IXTrme WFAISC&E STANDARD STORM MANHOLE COVER sw-10.10 CO o � U ICI • O QFji U � L"q'd N O�b Q' U d -moo z • W I � 0 In C) OUz GO u� �`O Nato co Q � � r O) N V ,,,,`TIJIIIIII�� N CAR C��' • • S '•, DINE. ,�//111111111 A, O 0-4 In W a �C'211112� O o F+•'1 w 1 O W O z N O I w 5 wwO m M F� 00W�� A z � � A W z 5� !r � PROJECT NO- H TG-1 801 0 FIIENAm: HTG18010—D1 CHECKED BY: RSS DRAWN BY: J M S scALE: N . T. S. DATE: 10-16 —18 SHEET N0. D-5 x PRELIMINARY DRAWING e NOT RELEASED FOR CONSTRUCTION TI MCADAMS NYLCPLAST 12" DRAIN BASIN: 2812AG -- x (1. 2) It TEGRAM) DLiCT1LE IRON _ 1 RAh1E & GRATI- 10 MAF019ASIN C.0, iA1 PIPE BUR AL ^� DEPii PER PIPE DEPTV � '@ MANUFACTURER ;'I VA. CABLE IVVEKT HEIGH.rS RECOMNENDA'10N AVAILABLE (ACCORDING TO 0N.MA11LIFACTLR#6 PLAN81TAkE O=Fj REP. FAME AS MIN. SJMT'; DAPTBR ANGLES VMJ.ABLE 03W1- ACCORDING-O PLANS 1M1rA7ER1GHT J0: NT [GO RRUOAT E0 HDPE SHCWN:I i 4 VARIOUS TYPES 7F INLE-i & OUTLET 1OW-E}RS A`/AILRBLE 4'-12" FCH CJRi{J[sATEa I S]FE 1A]S N-1e11-AN'::GH C'UA_ WALL �. AD&HANCOR SINGI.F'NA I i. N-12HP, PVc S1 Y'1FR FX SDR 35) 'IIC CWV IEX SCA AC' PVT C9C'CIC965. COWLGATED & RIBBED FVC TI IC BACKrILL IVOTERI.AL "liQL CE 0RUsi ICU STONEOR"ICR GRANUL'1R M.TERiA_ MEETING T'1E REQJIREMENTS OF CLASS , CLASS II. ORCLA92111 MATERIAL AS DEFINE3'N ASTV C221. ISF]DING & 3ACNFILL rOR SLRF.ACE DRA N:FI'AL Fro 5HA_L BF PLACED & COMPACTED UNIF+]PW:`r IN ACCORDANCE WITH AS-M 02321 U?ATCaC;CIL li LIH'_F .:{1RLL BC L'I:L-ILO IIEpY 'ERA&111 iv5:xi l3-V�'L IL•31•IK, wll k kE 6:CE" I.3N CF THE EYtON12E;;R:ITE =R,,SAES SHALL a DUCTILE IRON PEP, ASTM AE3: -LADE 705. 05 D;ATJ BASIN TO BE CLS`319 TD PtM DETAI.S ?iSERS ARE NEEr7EO FOR oASPi3 CVER aT DUE TO S14IPPINGRE£TRC"1D4S. NEE DgAW NG NC. MOi- I[-OA.5 WWAAGE C*AECTD4 9TJ0 X INT TadTWS-SHALL COMFORM -0 A9TM D3212 FOR OORRUQATED -OPE JAW N 2Ri.ANCOR DUAL'WALL:,. N-1211P, d P'or,- YYIR. 7.IAFTFM1.7NiF\1[1I1N1Fl I nNAi1Y AUILFil'[C'.;W;' FCOFIER67N-1AINIMLIM .AN CIE B€TVJEEY AVAr'TEP5 SEE ❑RA'AI11G 14C_101r1• I ICL411 IF k1INWIDTPGIJlDEL,NE 10" MIN 11112KNESS Liu EELINE TRA'r r I O.Ar GC•N:,RFTF Nil AS D NgFNGnNS AnF FnR {3UIDELINEFV9PC5E30N1Y. ACTLIALCONCREfE5LAi3M'JSTBE DES IGNr-D TASlIX INTO 'CONSIaERATION LOrALxaR C%DITIDN3 TRA-'F C _OADING. 8 ME APPLICA3LE 0:-S GN FA IORB. j. W EE DRAWING NO, !001.115-11' FOR NON TRAFFIC IN51•.ALy►11CN t31 VARIATiLF 9 JIAP DEPTH ACCGR'DiW TO 6AN5 'B' MIN. BASED ON MANU ^1C-UR1NG R A, IAN GRATE OPTIONS LOAD RATIHG PART-- DRAWING# ➢ECESIRIAN NEETS FFIO 12B9CGP 7U , 117 202 ETANCIAFC IVEETS F420 129912GS 10 ! 111203 s D_IDCSVER NEE-2 H-20 199BCGc 7tr_•'-I I12CA N FIW1A PF CFSTPW N7F N <aR=rr;=a 7fr., 11.r�"nli J(..Ml GRC'P N416ysTt wA I L,C'Hf DL 1' 11.-7r11 (.II 12:11]I fto^-1v M6 7V'. 11J1,0 1299CGCL �r I" CrPIFR FP.AMF ,J f }r 1 a• srx In rnvPR. � �11 1Ai•7!I K I Sf4" I [TN^HFk P,rrl T I ZINC -PLATED ST=E_ rIRN 1 R ?91 THRU GRATz -AI v Drill.l N iR- TIIRIJ COUNTER3:)FE 0.75x.18➢F AP 14-21) THREAD NOTE. VACATION 4P IAC4b4G DEV CE MAY VARV 1:- 1­14 N !j,,rl:I, 1 5 cnr1LL:1 MA- IIWIN kV11101 GRAINY BY AJJ4 MATERIAL A30 VEPONA AVE WYI OR AST FAS rRCFRI=TARN MORTR THE RFCr'PT SWORD, GA SN'8 OR POSSESSICN OF THIS PRINTDDES MOT CONFER, DATE 7411 INN 1r101932-k43 -RANSER, OR JGENSE THE USE OF -HE DES GN OR N�1� ►ds� FAIT rmi 932.2A90 -'LHNICAL IN FORIVAT OK SHX[4 HEREIN A2Ap BV CA PROJECT M-NAME W" nY!14PL t-LMMM &PC DL'C` ON OF THIS PRINT OR Ally INF'CRMATION - Trr>= CONT.AINE7 FEIF N, OR 1,i4NLFA•"TURF On ANY DATE 7-W 12 N SOLI) LOC91NIG COVER ASSEMBLY ARI CL` HFR=FRp VA =f,R --IF r11 i�' 1 .'14i'F.E 171 i.'.TH=H.S IF• r, IR 3 r111EII EY,;Fr Fv S'FC,'I-IG'A.RI1T'N F=F.RI "I3N FRo, NVLOH:AST. n- nri nr a=< OYYG am A SCALE A SHEET I QF1 OWS NO. VIM1-14 W REV B NYLCPLAST WATER TIGHT SWAGE JOINT f - t N75 � 1 1 r C?. 8EE Q110414G No_ 7001.110-M4 FOR AaSftAN07R ,- P iN JI I L11HL 5.Alll.11:[:I IAA ILRIN 1YI IU I 3RAVIN BY d C MATERIAL WD VERQNA AVE N- 12 HP FELL INFORMATION NY. OPl AST kAF rkcmlFTARY RICHrS THE RFC.FIPT BIIPORO. W SU!'8 11�- 3CC Gi�,AWING NC•. 7JL'3•' 1 L'-I}31 rUl7 tiVAi CR IGH I OR P'7RSESSICN Of THIS PRINT D3E& MDT CONFER, RATE 9 C9 PYC FIRM 1779111Z4443 a'A'AGE, DINT DETAIL 'R,M1hSFER, OR JGENSETHE'JSE OF -TIE C£5CN qR FAY IT7G'� 43+2.2A90 ISYto lash - I a7 www n lasf•�lacnm 3 - DIMEN31IXV8 pfiE FUR REFERENCE ONLY • `--FINICAL IN R14T O HEREIN APPp BY �LC PROJECT N0.,91AME yR% Acr;l . DIMFNS3%i S AIAN VARY COWAIWFICY C'10N OF THIS OR PRINT OR ANY INFORMATION TITLE c CONITA.-fl]F EREN,D C41_*DI iTI MOF ANV DATE 3" 121i 12 AOSF+0NCOR H-12 HP TEE 4 - DI.VENSION. ARE IN NCNES ART ci F HFH.=Fro»ra. =L �R -iF nl,cl i>s_IRf m [�n1=Rs 15F17R9' 1` F)[.:E r'- Fr;-EC1= IC'A,RITTEN - PERNi16SIDN FF1t7M NT OPLNST. canine 4^1 1906 Sim A SCALE 1:0 SHEET 1 OF 1 DA'G NO, 129151600 REV A Section 2722 Engineered Surface Drainage Products GENERAL PVC surface dralrlage inlets shall be of the i-it ine drain type as ind-FL:ated on the cOr*act drawing and referenced within JTe contract 3pecifIcations. The ductile hart grates far each of these ffttings are to be considered an Integral part of the surface drainage inlet and shall be furnished by the same manufacturer The surface drainage Inlets shall he as manufactured by Nyloptast a III ivisIaiT of Advanced Drainage Systems, Inc., ar prior approved equal MATERIALS Tha inline drain required for thrs contract shall be manufactured from PVC pipe stock, utilizing a therrno-mo'din g process to reform the pipe shock to ttTe fuFin ished configuration. The drainage pipe connection stubs shall be manufactured from PVG pipe stock and formed to provide a watertight connection with the specified pipe system- This joint tightness shall conform to ASTM 03212 for joints for drain and sewar olaxfic p-pa Using flexible eiastameric seals. The flexible elastomeric seals shall ccnforrn to ASTM FA77 The pipe bell spIgo, shall be loured �o the inlire drain body by use of a swage mechanical joint The raw material used to manufacture the pipe stock that is used to manufacture the inline drain body and pipe stubs of the surface drainage inlets shall conform to ASTM Q'784 eel class 12554. The grates furnished for a surface drainage Inlets shall be ductile iron grates for sizes 8", 10', 12". 15'. 18", 24' and 30" snail be made specifically for each fitting so as to provide a round bottom flarige that closely matches the diameter of the surface drainage inlet Grates for inline drains shall be capable of supporting H-20 wheel loading for traffic areas or H-13 loading For pedestrian areas_ 12" and 15' square grates will be hinged to the frame using pins. Metal used in the manufacture of the castings shall conform to ASTM A53G grade 70-50-05 for d jrWe iron. Grates shall be provided painted black INSTALLATION The specified PVC surface drainage inlet shall be installed us ng Conventional ftexiole pipe backfill materials and procedures. The backfill material shall be cn shed stone or other granular material meeting the requirements Df class 1 class 2, or class 3 material as defrned in ASTM 132321- Beddrng and backfil for surface drainage inlets shall be '.veil pla cad and compacted uniforrr'V In accordance wit+l ASTM ❑2321- The drain basin body will be cut a the time of the final 1 r rode. N❑ or-dc stone er : ancrete block ' II her ulre to set The rate to the Flnai . ride he ht. Far H-20 load ated Installations a concrete nn will be oared g �'+ � d 9 g 9 1 9 P under and around the grate and frame. T he concrete slab must he designed taking alto consideration total soil conditions, traffic loading, and other applicable design factors. For other installation con siceration9 such as migration of fines, grounc water, and soft fou'ndatio93 refer to ASTM D2321 guidel inas C C �JB i3A INVERT J- } ALL DIPAENSI0NS ARE IV INGHFS I F P1+ N' i16T11.{iSL5 tilll31L[]1 rJA 1LRIN m INJ I ❑RAYIN BY LC MRrERIAL 3139 V!FONA AVE PJl'I OR AST HAS rRC I-TAP.Y C:HTS THE RFi�:PF BUFDRD 0A 30S18 FR RI OR POSSES5ICIJ OF THIS PRIAT D3ES MDT CONFER, DATE 1."9 PVC PHN IT101932.2d43 'R"LNSFER, OR JGENSE THE! 1EE OF -HE DES CN OR Nylo last fAk PT7('!832.2A90 T°CHNICAL INFOPJIATC'N SH3oWN HEREIN &PPP BY JX PROJECT NQ.iHAME wwwnl'bPlnsl•us.mm REPRC DL'0'•ON OF THIS PRINT OR ANY INFORMATION TITLE MJTAINE] I- ME N, OR 104NLFAC7LRE Or ANY DATE SFI9 12IAI - aO IN AU&NANGQR N-12 HP ART CI F HER FFRCIA. =tiR --fF nl;;rl:,E1JFE TO ITFI=FR IINNERSAL BELL INFGRVATIOH ISFnR3nFIFN FxCFr'-F"5"EG=1C'NRITTEN PERM ISEI311 FRO"N LOPA4T. Mn'NY1.1N 4I OVIG SIZE A SCALE RTS SHEET 1 OF I DM'G NO. YG01-110-3e4 REV A CO SIZE 9A ILrIN � 8A MAX 08 MIN 0I81dA1[ C MIN C MAIL D AVG 12" 15.338 15.`r19 iS.0A4 16.29�1 5.5DD 7.399 13.&li i�' 16.23r1 18.4'O tS.:175 In.i25 s cnn D.40a i6:>,42 1H" t1.329 22.199 23.5i7 P3A82 J_�aB "..955 ZU.I73 2d" 26.Ba3 28.289 30.88E 81.185 13.YJ3 '4.a'3 27.75't 30" 37.13� 3T_334 39-336 33-624 1�.254 '�b',2&l 3ra16$ 1 299CGSL 1P' G'RATF FRAME !� 17STANDARDr;RA'E 1 142-1.X1114"LONG HE1feCIl-T ZING -PLATED ST-E_ 11 DRI-L 0.201 THRLI CRATE ONLY / LYRIL, kJ 201 i I IRLJ JI COJPtTER60RE 0 76 K 18 DP _ TAP 114 0 THRFAD NOTE: LOCATION 4F LOOSING LEV CE MAY VARY . 1,� PH.N. ,11,Tlt 1A 5 4i!]M 11 rJA 11 RIN 1Y1 IN71 ❑RAVIN BY AR A MATERIAL 3130 VERCNA mt IJYI n0 AST HAS IPRCrRI=TARN R1::RTS THE RFC'F:FT WORD, oA Nil OR POSSE CK THIS PRI?,T ODES MDTC0 rz DATE 'r.S.ID PHN }10193Z42 0 "RAI+EFER, OR JGENSE THE! 1�E OF -HE DES CN OR Nylo last fAk {71%!SX.2490 T_tHNrCAL INFORVAT'C'N SHJWN HEREIN APPD BV EBC PROJECT NWINAME re fly4lask-u M REPRC luc- C'N OF THIS PRINT CR ANV INFORMATION TITLE CONTA INE] F ERE N, OR 9ANL FACTURE OF ANY DATE 2.20-10 12 IN STANDARD LOCA NG GRATE A55EMKIr ARi CI = HFR=FF(VI =I.:R - iF rll ii:I FL1J,1Rf TCI F_ H-F.R IS"I",I"nfrl Fx;,Er-r-"5"FCI =1C'A.NITTEN FERMIS.11 FROM NY LOP IST. amen mi "Fi a I OWG 512E A SCALE I:3 SHEET 1 OF I OHC NO. r001-`1"I REV C v • O t` Nm � N N M rl � I � A V ,,\11111111/1j- y' ''1/1111111\\\, O W a W � W Q w W O w � O O w 5 � wwo M M F� 00 z � � A I� 5 z PROJECT No. H TG-18010 FILENAME: HTG18010-D1 CHECKED BY: RSS DRAWN BY: Tf M S SCALE: N.T.S. DATE: 10-16 -18 SHEET N0. D-6 x PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION fJ MCADAMS 7 5 I inn Al I nWARI F NFIrNT 40 I\LI VVL I"1V VLVV I\V LL'VI VI'11 \I'1VL VVVI\ LEVEL 02 -09 - TOTAL WALL AREA = LEVEL 02 -09 - TRANSPARENT AREA = LEVEL 02 -09 - TRANSPARENCY % _ TRANSPARENCY % REQUIRED = LEVEL 01 - TOTAL WALL AREA BETWEEN 0 AND 12' ABOVE ADJ. SIDEWALK = LEVEL 01 - TRANSPARENT AREA = LEVEL 01 - TRANSPARENCY % = TRANSPARENCY % REQUIRED = UDO ALLOWABLE HEIGHT ENCROACHMENT (UDO 1.5.7.D3 c + g) Tnr) nr M r\/ATnr) nUr!M0I IAI LIDO 3.4.2.131 -ACTIVE GROUND FLOOR THROUGH RETAIL STOREFRONT AND PROGRAM HEIGHT / STORY COMPLIANCE - UDO 3.2.6 UDO 3.3.1 - MAX HEIGHT: 7 STORIES ALLOWED 90' MAX HEIGHT ALLOWED LIDO 3.3.2 - MIN HEIGHT: 2 STORIES MIN ALLOWED 75% MIN STREET FACING FACADE AT MIN HEIGHT LEVEL P9� 446' - 8"� LEVEL P8� 436' - 0" LEVEL P7 425' - 4" LEVEL P6 � 414'-8" LEVEL P5 � 404' - 0" LEVEL P4 393' - 4" LEVEL P3� 382' - 88" LEVEL P2 372' - 0"� LEVEL P1 � 353353' - 6" NIA 89' - 6 3/16" SHOWN AWL Now - EL MEN m i -lion — ----------------- I momm�. I I I'l M i 6VE 1 �11 milli MIMI \� UDO 3.4.2.131 -ACTIVE GROUND FLOOR THROUGH RETAIL STOREFRONT AND PROGRAM LEVEL 02 -09 - TOTAL WALL AREA = 1,906 SF LEVEL 02 -09 - TRANSPARENT AREA = 1,906 SF LEVEL 02 -09 - TRANSPARENCY % = 100% TRANSPARENCY % REQUIRED = 20% LEVEL 01 - TOTAL WALL AREA BETWEEN 0 AND 12' ABOVE ADJ. SIDEWALK = 2,142 SF LEVEL 01 - TRANSPARENT AREA = 1,831 SF LEVEL 01 - TRANSPARENCY % = 75% TRANSPARENCY % REQUIRED = 85% PARKING GARAGE VEHICULAR ENTRY PARKING GARAGE ELEVATION - EAST ELEVATION (BOYLAN AVE) PARKING GARAGE ELEVATION - NORTH (HILLSBOROUGH ST) 2 SCALE: 1/16" = V-0" SCALE: 1/16" = V-0" LEVEL P8.5 87' -10" LEVEL P7.5 77' - 2" LEVEL P6.5 AIL 66'-6" LEVEL P5.5 55'-10" LEVEL P4.5 45'-2" LEVEL P3.5 34' - 6" LEVEL P2.5 23' -10" _ LEVEL P1.5 360' - 0" VG. GRADE PLANE j1 357' -1 13/16" LEVEL P8.5 87' -10" �j LEVEL P7.5 77'-2-2" LEVEL P6.5 66'-6-6" LEVEL P5.5 55' -10" LEVEL P4.5 45'-2" LEVEL P3.5 34' - 6" LEVEL P2.5 23' -10" � LEVEL P1.5 360' - 0" HEIGHT / STORY COMPLIANCE - LIDO 3.2.6 UDO 3.3.1 - MAX HEIGHT: 7 STORIES ALLOWED 90' MAX HEIGHT ALLOWED LIDO 3.3.2 - MIN HEIGHT: 2 STORIES MIN ALLOWED 75% MIN STREET FACING FACADE AT MIN HEIGHT BLANK WALL AREA COMPLIANCE - UDO 1.5.10: NO BLANK WALL AREAS THIS ELEVATION ELECTRICAL TRANSFORMER VAULT ACCESS ROLL -UP GARAGE DOOR NIA 89' - 6 3/16" SHOWN _ LEVEL P9 OIL 446' - 8" ao 0 _ LEVEL P8 436' - 0" ao -- _ LEVEL P7 OgL 425' - 4" 0? _ LEVEL P6 OIL 414' - 8" ao 0 LEVEL P5 404' - 0" 00 0 LEVEL P4 OgL 393' - 4" 00 0 _ LEVEL P3 382' - 8" 00 0 _ LEVEL P2 372' - 0" BO AVG. GRADE PLANE 357'L-ElVft/' 1' 353' - 6" Alk. HERITAGE PRf]FERTiE5,1NC 701 HILLSBOROUGH STREET Gensler 530 Hillsborough St. Tel 919.239.7836 Raleigh, NC 27603 Fax 919.239.7828 United States Date Seal 1 Signature Description NOT FOR CONSTRUCTION Project Name 701 HILLSBOROUGH STREET Project Number 90.0279.001 Description PARKING GARAGE ZONING ELEVATIONS Scale 1 /16" = 1'-0" *FOR REFERENCE ONLY, NON-PUBLIC FACING FACADE NO NK BLANK ALL EA AREAS *FOR REFERENCE ONLY, NON PUBLIC FACING FACADE NO BLANK WALANK WALL LL RAREAEA S MTHISELEVATONLIANCE - UDO 1.5.10: NO BLANK WALL AREAS THIS ELEVATION 4 PARKING GARAGE ELEVATION - WEST PARKING GARAGE ELEVATION - SOUTH SCALE. 1/16 = 1 -0 SCALE. 1/16 = 1 -0 A0m01 © 2015 Gensler ATTACHMENT B SITE GRADING PLANS v 0 a X HILLSBOROUGH 630 LLC AYCOCK, MAHLON L WILDER, RYON W N/F N/F L_ II 630 HILLSBOROUGH STREET I 618 HILLSBOROUGH ST I HSA LIMITED PARTNERSHIP THE BAR STOOL INC PIN 1703-49-1348 PIN 1703-49-2349 610 HILLSBOROUGH ST 600 HILLSBOROUGH ST DB 2790, PG 13 PIN 1703-49-3325 DB 4908, PG 342 PIN 1703-49-4345 - - - - - - - o I X DB 16997, PG 1152 EXISTING 0.38 AC. I 0.34 AC. DB 13828, PG 1200 0.30 AC. HIT LSBOROUGH ST. ZONING: NX-7-UL z o 0.18 AC. I II ZONING: NX-7-UL L ZONING: NX-7-UL x x /i // '- ❑E �� - - - I (VARIABLE V ZONING: DX-7-SH ( ABLE WIDTH PUBLIC R/W I 1 Wv W'WTw W- we wc� I c c c c_ -y -i- - _ -_ 35 w w w G�c --;�__-`_ -___�1 __-- _SS SS EX. RCP 8" SS W W- W!w- w / w- w- r_L cLD � G c c c --- L=== ==�1 __-- - f�---- _ --- -� [�}-� ------ ss EX. I�P 8"3SS T 9 W W w W___ � c c c c " c- T� - - - FO F0FO - - ss w- I _ OX-7-UL I �- \ w w W w EX. 8w CIP W/w (ASSUMED LOCATION) o =_ - - - - - %- - - IT � ss _ NX-7-U d ss EX. 8" RCP SS W - L - 3 3 SS W W w \ wv SS -SS W W- / � \ g _ SS ss SS ss 6 \ \ '"-�W- W__w� NX-7-UL� 9 �' ss EX. 8" RCP §S W- w ySS X 12 UG \ ■� I�� I PRECAST CONCRETE / / I _ WALLS TYP. ■� Q3 _ - 9 � 6 - _ _ _ - - - (DESIGN BY OTHERS) �� T - i�S / LIMITS OF PROPOSED Fl� # 5 - �\ 4 LD �D - DISTURBANCE - - g LD - IE LD LD I / T I ` - _ 3n 3n LD LD LD I 6 `� �I I I Ir--------=__-- - \\ AREA DRAIN--- / ( III PI I P:353.8 --- --� - - = = - (TYP.) II I I I I _E353.8- `� Z - ------ \ I _ I-�� 31 I r -I---- i - I-�- _-- - ✓ \� 353.97 � � V 52 90 � I 3 353.30 353.30 >• \ 353.97 353.97 353.97 I v Y - - - - - - _ - I 3 I 1 - 352.97 - - I / I I�,p O�-• I �„ FFE- I I 1 20' WAX. � - 33 353.97 I BUILD -TO I ^I \ J 3 I P:352.00 LIMITS OF I I / \ 35.97 I ' / E:351.30 1 I JI DISTU E 352 97 29 O I FIRE RETAIL 8" Pvc 1 �i I 352.05 '� �I i I I 30'x3O' CORNEE i DTT1fD FFF=1152.97 STORMz�_ I; ^1 I Z o I I N/F I 1 J I FMW AT 701 HILLSB ROUGH LLC R 701 HILLSBO O GH ST ( it PIN 1703- 0106 ' - - I � I DB 16937, 2509 Z --+ I ) / N BM 1987, 12 1251 0.43 L u N I J ZONING: X II I (� w I 353�97 II II I I I I\ 7 I� I I I X o I I/ \ I � I I I N I I I 0& �� • C ISTEPI �I j" - � HANDSf�,ILSH I (PROP 0SE$ TLTTl7R €--F'RO-J EE & I I/ REFERENCE ONLY ASSUMED 100� IMPERVIOUS) I I I I I \ TRANSACTIONS 573539 11 I II II I �I I 352.8 CASE # SR-100-18 I II I IN � II 352.8C \ \ I II I 352.80 \ \ I I II 352.80 I 352.80 - RIM=3- V \ I 8"VCP(S)- 46.01 II • I,� I 352.0- �OSED 352.00\ ip 11 17 II- i �I Ip� DUI I I ^ 51.97 - 3 700 WESTNMORGAN LLC I I ICI II I 0I 00 I PIN 1703-49-0004 a x DB 11755, PG 933 I II \oo ``' / 9 0.15 AC. ZONING: NX-7-UL + mil II x l x I I IIDI�t III �o �IF- EX. CB J TOP=351.99 12"RCP(E)=349.47 I I v / x -T----�--- ----� I W o \ \ \ EX. C� \ � � � \ TOP=35Z. 6 \ \ \ \ � 12"RCP(E)=-3W_40 53 \ \ 1 W Wv \ NX-7-UL I I II w w w OX-7-UL - 7SSMH I / / RI"�352.57 I ZEE&__VCP(N)=344.38 8'VCP(S)=344.26' ou ou I -----=_--- no no flo \1 n0 \ I / NF PLANNED PARENTHOOD OF GREATER RALEIGH INC 100 S BOYLAN AVE PIN 1703 38 9868 DB 4798, PG 489 I r B 0.47 AC. ZONING: OX-7-UL RETAIALL =IGN�BYV OTHE,� EX. JB �/ (ASSUMED 18LOCATION) RIM=352.17 RIM- 50.40 I LIMITS OFF 18"RCPO=349.34 INV IN(N)=346.41 DISTURB NCE 12"RCPAW)=349.46 INV OUT=346.41 / (TYP.) 12"RCf(NW)=359.58Ij FCO 013 ang KIM=J4 Jy EX. SSMH INV I ( )=338.79 RIM/345.38 1 CP(W)=338.79 8"VCP(E)=338.23 I RCP(E)=338.79 - - - SS -EX. 8" DIP SS SS SS __ 6 p I I EXISTING - - -� d I W.®���� cT• EX. SSMH / PPP I I (VARIABLE IJ I ! RIM �43 25- 3#4/ IIII r i I ( BLE WIDTH PUBLIC R/yv) f \ ,8 DIP(E)=333.06 8"DIP(W)=334.74 N/F l / 10"DIP(16"ENCASEMENT) I il' I I CROCKER FAMILY PROPERTIES, LLC I j \ (S)=333.05 MORGAN 11 PIN 1703-48-1885 / DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL 15"RCP(S)=337.27 / EX. JB-1 13 RIM=342.90 15"RCP(N)=336.93 15"RCP(W)=336.93 15"RCP(E)- 36.93 _-- - - - 8" IP _L _ �A I 101 344 L I- I ' STEPS WITH LOT 3 r r -j y� (TMP) AILS 41,611 SIF a- t0.955 AC =_ 6 ZONING: DX-12-UG� I r & DX-12-UL AREA DRAIN r� (TYP.) 0' OR 6' BUILDING SETBACK FROM J1 8" PVC STORM T SERVICE PRIVATE DRAINAGE EASEMENT a rr4 � S " al I II ACCESSORYSTRUCTUREII SOUTH BUILDING Ii FFE=346.79 EX. PRIVATE DRAINAGE EASEMENT EX. SSMH RIM=343.38 8"DIP(E)=334 27 PREVIOUSLY APPROVED PROJECT SEE CITY OF RALEIGH CASE #SR-45-16 8"DIP(S)=334.27 r r - - - -I- -\-/ 0 - - i ram, ---•FPS as __ � _ _ EX. /CB-110 - L T/q=345.37 / 15' RCP(E)=339.17 N a w��w"RCP(W)w 339.07 w / EX. JB-106 a52RIM=343.07 1i RCP(NE)=3366 °° ^� 15" RCP(E)=336A 6 �I > w I 15" RCP(W)=336.16 12" PVC(NW)=339.21 18" RCP(S)=336.06 EX. SSMH SS RIM=342.98 8"DIP(N)=333.68 r - - 8"DIP(W)=3 3.48 as - - - -SSSSp� SS SS M�� SS I I I I N/F I RALEIGH HOTEL GROUP, LLC - - . _ I- - - - 603 W MORGAN ST PIN 1703-48-4920 DB 16986, PG 2031 0.23 AC. ZONING: DX-7-UL r J/ / / / / -sow so e - - -' r\ / SP SS/ n GRADING LEGEND CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN O JUNCTION BOX ��--- DRAINAGE FLOW ARROW 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION P-250.00 PROPOSED AVERGAGE GRADE PLANE SPOT E:248.00 EXISTING AVERGAGE GRADE PLANE SPOT STORM DRAINAGE STORM SERVICE LINE LD LD LIMITS OF DISTURBANCE 250 MAJOR CONTOUR 252 MINOR CONTOUR ------_ 250 EXISTING MAJOR CONTOUR ------- 252------- EXISTING MINOR CONTOUR EASEMENT LINE SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. DISTURBED AREA = 2.00 AC. EX. CB-117 T/C=343.17 INV IN=338.41 (JB-117A) INV OUT=338.31 JB-117A RIM=344.90 INV IN=338.80 (JB-117B) INV OUT=338.70 JB-117B RIM=349.75 INV IN=339.35 (SWMF) INV OUT=339.25 SWMF RIM=349.50 INV OUT=339.50 SWMF RIM=349.50 INV IN=346.10 (JB-200) JB-200 RIM=349.50 INV OUT=346.50 GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT HERITAGE PROPERTIES 501 FAIRMONT AVENUE, SUITE 101 TOWNSON, MARYLAND 21286 PHONE: 410. 769. 6139 HERITAGE PROPERTIES, INC W z� U W W M ^ I..L F �0 I (A N M V = z 00 z 0 J �OU Z) = VQor- O °COF- = J 0 m O m z z 0 (D LU U M < N�N N Ln z O U 0%uuu 0%% �\A CA, ••�� - WO& . S. SLP.•`��,, REVISIONS NO. DATE 1 XX. XX. XXXX REVISION DESCRIPTION PLAN INFORMATION PROJECT NO. HTG-17000 FILENAME HTG17000-G1 CHECKED BY CHT DRAWN BY CHT SCALE 1" = 20' DATE 12. 15. 2018 SHEET GRADING PLAN C-s PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION N/F WILLIAMS- CROSS INVESTMENT CO INC _ N/F 1 706 HILLSBOROUGH ST = _ 1 - - I I HILLSBOROUGH 630 LLC PIN 1703-39-9454 li DB 1408, PG 569 I I I I 630 HILLSBOROUGH STREET - - - 0.67 AC. , f PIN 1703-49-1348 152 _ ZONING: OX-7-UL Li I DB 16997, PG 152 J� 0.30 AC. �Ir - _ 0e e / - / / - - - '' ZONING: NX-7-UL _ \ EXISTING \ \ s w �° = s _ EX. GAS LINE- Tw wss I w��o o \ ®� ® �lJ 'lx �J \ - ss EX. 8" SS \ \ w W- w -o- (VARIABLE � LIMITS OF ) � so, -Ss � \ 9 Ex. WIDTH PUBLIC DISTURBANCE I s\- ss ss 8" ss w- W RAW) I TYP. s - ss ss (TYP.) -$- ss CITY OF RALEIGH STANDARD / / ss gg SEX. 8" SSA 1 / I GRANITE CURB ALONG SAWCUT REMOVE AND /. � \ HILLSBOROUGH STREET. / REPLACE AS REQUIRED FOR / I 9 LIMITS A a y' A !TSS _ I 9 I DISTURBANCE IF REUSE OSSIBLEGRANITE CURB / \ UTILITY RUTILITY IEMOVALAPEERECITY PROP. BIKE ��SAWCUT REMOVE AND CONCRETE / (TYP•) REPLACE AS REQUIRED FOR \ / OF RALE H STANDARDS RACK (TYP.) / SIDEWALK / \ ROADWAY IMPROVEMENTS - % I ACCESSIBLE PER CITY OF RALEIGH I �4 X6 ADA TREE / � I 9 RAMP - I STANDARDS m ATE TYP. 9 6 .... (n �� ) _L I 4'X6' ADA TREE . ......... s ...... ` m �� / ...................... LIMITS OF / .......................... n ATE TYP. _ s - - _ .......... ....................� I ��."................. "} ... DISTURBANCE / - ��- - rw .............. ...... m _1.......................... (TYP.I . ... . . \ \ ............ 9 � s. ........... .... PROPOSED /ACCESSIB E �&oA0 _ �� 359.10 1 - + ✓ - - - RAMP 360.25 / L A a DECK I RETAINING WALL 360.= NTRANCE 358.20 w I (DESIGN BY OTHERS) � FFE �� I � � 356.67 / 355.58 I �.".".". ." " 9 NOTE: 360.25 / 20' MAX. OTHER OPTIONS SUCH AS \ -� / BUILD -TO GRADING ON ADJACENT PROPERTY IN LIEU OF WALL WILL BE EXPLORED AT TIEM OF FINAL SITE PLAN _ RETAIL 1 I 2,772 SF I � RETAIL \ /354 `� I � I I v IROOM �\ F7E=358.20' \�I 1,575 f FFE=35 .58 35"o RETAIL 2 9 2,407 SF 30'x30'F RNER J FE= 53.85 353.85 I 10 \ I FFE=356.67' LOT BUITo 11 359.50 2 MOVEABLE PLANTERS FOR REQUIRED AMENITY = W I � I 9 L 6 I I--� 359.50 359.50 7 AREA TREES _ _ / I ACK TYP.) �4 vl I FFE=359.50 L OEWALKNCRETE I I. _ k 353.46 �® II "� III-, 20' MAX. L � � BUILD -TO i h PARKING N/F r y GARAGE RETAIL 4 I I X II I I I THE JUNIOR LEAGUE OF RALEIGH INC LIMITS OFDISTURBANCE I - \ 258,861 SF 1,718 SF I I I o I I 711 HILLSBOROUGH ST. 1 a I I FFE=353.46 I) PIN DB 12630, 1703-39-7175 (TYP.) I I � I \ / II I ' 9 EXISTING 1 I r II I I rri I� I O R/W 1.16 AC. - I I I 353.19 1 c, m II ZONING: OX-7-UL m 353.46 I 1 I II I V ) RO M 353.463.19 II 0' OR 6' BUILDING SETBACK I \ I I '�II ( 353.19 FROM SIDE LOT LINE I I L _� I \ A II I I I v v 9', I I FFE=359.50/ I I I I 1 I� DECK 9�� I ENTRANCE LIMITS OF ^� I DISTURBANCE II 12" PVC STORM I JB (TYP.) (TYP.) I I a I I AREA DRAIN I SLOPE AND 1' MIN I \RESIGN D AT TIME OOF LEADERS\ 15" RCP ) M I I I I I (TYP.) p 07 MINIMUM COVER 0\ FINAL SITE PLAN SSMH M=353. I 3 .... .. /8'VCP(S)=3 I6.01 I 352.75 i.. 4'X6' ADA T EE �\ GRATE (TYP. EX. 1 -STORY BRICK BUILDING I EX. - _ 12" PVC STORM I I Ir I 2-STORYFRAME 7 - - rt \ (' SERVICE ® 1 MIN II BUILDING LIMITS OF I �- - = - - - - - - _ _ , - - SLOPE AND 1' L I DISTURBANCE _ MINIMUM COVER EX. 3-STORY 17 s 9 EX. BUILDING OVER (TYP.)I EX. BUILDING OVER BRICK BUILDING I AREA DRAIN PROPERTY LINE EX. WALL PROPERTY LINE I I I (TYP.) I II 3S� 1 I I �. I II 1\ 1 1 H 0' OR 6' BUILDING SETBACK I EX. WALL I s g I II 1 FROM SIDE LOT LINE I I II 115" RCP N/F z I II 1 I SAMIH T& REBECCA A YEHIA RVCBLE I I s V) TRUST THE YEHIA, SAMIH T TRUSTEE N/F 8 \a 704 W. MORGAN ST. 700 WEST MORGAN LLC IO PIN 1703-39-9004 PIN 1703-49-0004 I Q 1 DB 11755, PG 933 DB 15062, PC. 676 0.15 AC. 6 �\ 1 ZONING: NX-7-UL � x\ 1 o III I H ZONING: NX-7-UL I N w ¢ CONVERT EX1 - _ - - I - - EX. SIDEWALK 6 9 TODCORSCB STD CB I� - / h� � I � ------ \ ---7- �_ I / 15�RCP y no \ \ F \ so �° so EX. CB \ �- \ \ \ TOP=354.9� EXISTING \ 12"RCP(E)=3550.40 \ 3 \ \ �nT T w *V iY . MORGAN S�'. 11 I III w w w 0 w w w- (VARIABLE WIDTH PUBLIC R W \ I \ EX. SSMH - / -\-- RIM--352.57 I I1 I I EX. JB CP(NS'�)=344.38 RIM=352,1/7 (S)=344.26- � 18"RCP(t)= 349.34 T` 8"VCP"RCP _-- 12XW)=349.46 I -� ou_ 12"RCP(NW)=359.58 ou Mo no no no I EX. SIDEWALK \ 1 - � I013 �� I� THE COLEMANFGROUP LLC N/F 705 W MORGAN ST I PLANNED PARENTHOOD OF GREATER 1r I► lu ` I PIN 1703-38-8847 RALEIGH INC y I I I DB 15399, PG 1 I 100 S BOYLAN AVE II 111 I I 0.29 AC. PIN 1703-38-9868 ZONING: OX-7-UL DB 4798, PG 489 I I ZONING47OXA. C7-UL III �I u II 12 ) II I I BLOCK 83 PROJECT ZONING: DX-12-UG - - (UNDER SEPARATE COVER II TRANS# 559068) (�1 I I r \ I I �l I JL----------- 1 SAWCUT REMOVE AND REPLACE AS REQUIRED FOR---- -- UTILITY TIE-INS AND EX UTILITY REMOVAL PER CITY OF RALEIGH STANDARDS EX. CB T/C=350.68 INV OUT(S)=346.68 CONVERT EX. CB TO COR STD CB Mo so EX. JB/ (ASSUMED LOCATION) RIM- 50.40 INV IN(N)=346.41 INV OUT=346.41 _ � no no N/F CROCKER FAMILY PROPERTIES, LLC 615 W MORGAN ST PIN 1703-48-1885 DB 16759, PG 165 0.63 AC. ZONING: DX-7-UL GRADING LEGEND CATCH BASIN DROP INLET ■ STORM SERVICE INLET • STORM SERVICE ROOF -DRAIN O JUNCTION BOX �-� DRAINAGE FLOW ARROW 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION STORM DRAINAGE STORM SERVICE LINE LD LD LIMITS OF DISTURBANCE 250 MAJOR CONTOUR 252 MINOR CONTOUR ------- 250------- EXISTING MAJOR CONTOUR 252____ EXISTING MINOR CONTOUR - - - - EASEMENT LINE SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF RALEIGH ENGINEERING DESIGN AND CONSTRUCTION STANDARDS *WARNING* ACTIVE GAS LINES ARE PRESENT IN THE VICINITY OF THIS PROJECT. CONTRACTOR TO FIELD VERIFY AND LOCATE ALL GAS LINES AND OTHER APPLICABLE SITE UTILITIES PRIOR TO CONSTRUCTION. DISTURBED AREA = 1.00 AC. GRAPHIC SCALE 20 0 10 20 40 1 inch = 20 ft. Co 0 � v • o C'ed,Nm � 00 C49 d �Z 00 �z00 o� oLo 0) CID CV Co F� CA ter^ V/ � A V �N CARL)/ 1109 S. 0 5 w a cz co W C\2 Z '4 w Q O � � �--1 ✓- Q z pq a I -AU O z Qi z 14 W �--1 O A O z Lo O W 5 a V �l Z CM F-+ o/� 00 A to v A v Z z a� z Z C� PROJECT NO. H TG-18010 FILENAME: HTG18010-G1 CHECKED BY: RSS DRAWN BY: iM S SCALE: 1 _ 20' DATE: 10-17-18 SHEET N0. C-5 x PRELIMINARY DRAWING - NOT RELEASED FOR, CONSTRUCTION IJ MCADAMS ATTACHMENT C CONSTRUCTION SCHEDULE _ — —_ ____ O Demo Start O Release Steel Mill Order O Sitework Start *Submit Building Permit — — — — —_ 91FoundaYions-Start---------------------------- *Steel Start ♦ Steel Top Out *Building Dry -In ♦PerminantPower Available ____________________ *TemCoolinyAvailable _____________ e - I - *-Office Tower Core & Shell Substantially C 00075 Release Steel Hill Order 0 03/20/19 00035 Submit Building Permit 0 05/01/19 00115 Steel Start 0 08/30/19 00125 Steel Top Out 0 12/18/19 00095 Building Dry -in 0 03/27/20 00085 Perminant Power Available 0 04/02/20 00025 Temp Cooling Available 0 05/15/20 nnn4.1, Off cp Tower Core & Shell Substant ally n 08/25/20 CD - Demo / Sitework Bid Package Construction Documents Office Tower Site Work 00265 CD - Demo / Sitework Bid Package 15 11/02/18 12/20/18 Core & Shell 500% CDs - Core & Shell Office Building o CD - Foundations / Steel Bid Package 95% 00275 ° 00285 CD - Foundations / Steel Bid Package 50 12/05/18 02/12/19 00305 Document oCoreODocument Estimates / GMP 0 50% CD Level Cost Estimate 0 50% CD VE - Core & Shell Office Building 0set GMP ° 00295 50% CD VE - Core & Shell Office Building 20 01/09/19 02/05/19 90k SF Tenant CDs - 90k SF Tenant o Bid 90k SF Tenant 0 Set GMP - 90k SF Tenant - 90k SF Tenant 50 01 /07/19 03/15/19 k0335CDs 0375 Set GMP - 90k SF Tenant 1 10 04/15/19 04/26/19 Permitting & Approvals Office Tower 1W o Demo Permit o Road Closure Permit o Sitework Permit 0 00365 Demo Permit 10 12/21/18 01/03/19 00345 Sitework Permit 55 12/21/18 03/14/19 Award - Demo Award - Sitework & Utilities Award - Survey O Award - Landscape 0 Bid / Award 00475 Award - Sitework & Utilities 5 02/20/19 02/26/19 00505 Award - Landsca a 1 15 06/03/19 06/21/19 tart date 7 1 18 p Early bar p Progress bar critical bar Summary bar Start milestone point Finish milestone point WHITING -TURNER Block 83 - PRELIM Finish date 09t 20 Data date 18 Run date /18 a enum r rimavera ystems, nc. Act Description III) 173 02/27/19 1 10/25/19 Q1 Q2 Q3 .. Q1 Q2 Q3 .. 1 _ - - - - Mobilize / Set uD Site Access Control Wo Demo Structures Survev & Control Plan G SEC / Sediment Basin _ _ _ _ _ ——ULlity StraeLTie-Ins - mq[aan— - G Clear & Grub Site o Rouah Grade Build Buildina Pad - PH 1 Site Electric Rough -In Install Site Water 0 Install Site Strom - - - - - - - - - - - - - - - - - - Install Site Sanitary n Sand Filter Piping / Sand / Lids Install Grease TraD o Utility Tie -Ins - Hillsboroah - — — — — — to SBLSubaradel Intall 13o&Araund-Bu1ldlnaPad- 8 Grading Building / Site - Phase 2 - Zone A & B 0 Site Work 00855 Demo Structures 20 03/13/19 04/09/1 01685 SEC / Sediment Basin 1 10 04/10/19 04/23/19 Toe-ins01095 Utility Street - 00865 Clear & Grub Site 1 8 04/24/19 05/03/19 01025 Site Electric Rough -In 1 15 05/06/19 05/24/19 00945 Install Site Strom 1 10 05/20/19 05/31/19 00935 Sand Filter Piping / Sand / Lids 1 10 06/03/19 06/14/19 00965 Grading Building / Site - Phase 2 - Zone A & B 1 7 07/26/19 08/05/19 +North Facade 40 04/28/20 06/22/20 +South Facade o +East Facade 60 04/29/20 07/21 /20 +West Facade 55 05/13/20 07/28/20 — — — _ _ 1 1 _—__ 1 Fi Confirm VE / Foundation / Steel Packaae 1 Award - Piles Award - Cast -In Place Concrete 1 Award - Curtain Wall — — — i Award --Steel/ Ow.-Matats _ — — — — — — . 1 Award - Metal Panels o Confirm Construction Documents 1 Award - Masonry Award - Mechanical _ _ _ _ _I Award -Plumbing_ Award - Fire Sprinkler Award - Electrical Award - Elevator Award - Waterproofing — — — —__ GAmtard_RuckHnist__—————— o Award - Framing / Sheathing / Stucco o Award - Doors / Hardware o Award - Roofing 01355 Award - Piles 1 5 02/27/19 03/05/19 01395 Award - Curtain Wall 1 5 02/27/19 03/05/19 06445 Award - Metal Panels 1 5 02/27/19 03/05/19 06425 Confirm Construction Documents 1 10 105/01/ 01405 Award - Masonry 1 5 05/15/19 05/21/19 01425 Award - Plumbing5 05/15/19 05/21/19 01445 Award - Electrical 1 5 05/15/19 05/21/19 01555 Award - waterproofing 5 05/15/19 05/21/19 01485 Award - Framing / Sheathing / Stucco 1 20 05/15/19 06/11/19 01545 Award - Roofing 20 05/15/19 06/11/19 tart date 07/01/18 p Early bar p Progress bar Critical bar Summary bar Start milestone point Finish milestone point WHITING -TURNER Block 83 - PRELIM Finish date 09/22/20 Data date 11/0 18 Run date 11/29/18 a enum r nmavera ystems, nc. +Submittals o +Procurement 170 04/10/19 12/03/19 +B 1 M 60 05/22/19 08/13/19 Tower Construction 1 It +Hoisting 142 1 11/13/19 05/28/20 tructure — 1 1 1 - _ _ Auaer Cast Test Piles Mobilize ' Auger Test Pile Cure / Testing Install Piles - Zone C G Install Piles - Zone B — — —' Excavate Eoundations =Zone C. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Chip Piles - Zone C o Foundations - Zone C Excavate Foundations - Zone B Install Piles - Zone A _ _ _ _ _ _ - - o Elevator / Lateral Frame Pile Caps _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ o Chin Piles- Zone B 0 Foundations / Walls - Zone B ' Excavate Foundations - Zone A ' Chip Piles - Zone A 0 Foundations / Walls - Zone A Foundations 01785 Auger Test Pile Cure / TestinC, 1 5 05/27/19 05/31/19 03055 Instal I Piles -Zone B 1 10 06/12/19 06/25/19 03135 Chip Piles -Zone C 1 5 06/19/19 06/25/19 03065 Excavate Foundations -Zone B 1 3 06/26/19 06/28/19 03025 Instal I Piles - Zone A 1 7 06/26/19 07/04/19 03155 Elevator / Lateral Frame Pile Caps 1 20 1 06/26ii 91 07/23/19 03085 Foundations /Walls - Zone B 1 12 07/02/19 07/17/19 03045 Chi Piles - Zone A 1 5 07/09/19 07/15/19 03105 1 Foundations / Walls - Zone A 1 10 07/12/19 07/25/19 Ground Floor — ' Staircase Slab -On -Grade ' Slab -On -Grade - Zone A ' Set Steel Columns / Beams FL2 - Zone A n Slab -On -Grade - Zone B Set Steel Columns / Beam FL2 - Zone B — — — — n — — — — — — — — — — — — — — — — — — — — — — — — — — ' Set Steel Columns / Beams FL2 - Zone C G Misc Steel Lintels / Brick / Wind / Etc - FL 1 03245 Staircase Slab -On -Grade 1 5 08/23/19 08/29/19 03185 Set Steel Columns / Beams FL2 -Zone A 1 6 08/30/19 09/06/19 03215 Set Steel Columns / Beam FL2 - Zone B 1 6 09/04/19 I 09/11/19 03255 Misc Steel Lintels / Brick / Wind / Etc - FL 1 1 10 09/19/19 10/02/19 +Second Floor +Third Floor 28 09/23/19 10/30/19 +Fourth Floor 28 10/02/19 11 /08/19 +Fifth Floor +Sixth Floor of o +Seventh Floor m 28 10/29/19 12/05/19 +Eighth Floor tart date 07/01/18 p Early bar p Progress bar critical bar Summary bar Start milestone point Finish milestone point WHITING -TURNER Block 83 -PRELIM Finish date 09/22/20 Data date 11/0 18 Run date 11/29/18 enum r Wa nmavera ystems, nc. +Ninth Floor 25 11 /19/19 12/23/19 +Tenth Floor 511101 28 11 /27/19 01 /03/20 +Roof t=11 + r Skim 154 1 11/28/19 06/30/20 +Interior +Elev ators 73 03/04/20 06/12/20 Testing / Closeout 92 05/18/20 09/22/20� Start date 07/01/18 p Early bar p progress bar Critical bar Summary bar Start milestone point Finish milestone point WHITING -TURNER Block 83 -PRELIM Finish date 09 22/20 Data date 11/0 18 Run date 11/29/18 enum r Wa rimavera ysI.rn nc. ATTACHMENT D DATA SUMMARY TABLES Table 2 Soil Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 1 of 4 Sample Identification Maximum Soil Contaminant Concentration Levels (MSCCs) Preliminary Soil Remediation Goals Analyte GTA-01 (28') GTA-02 (11') GTA-03 (22') GTA-04 (19') GTA-05 (28') GTA-06 (12') GTA-07 (12') GTA-08 (26') GTA-09 (24') GTA-10 (21') Soil -to -Water Maximum Contaminant Concentration (Soil ug/kg) Industrial/ Commercial Soil Cleanup Levels (ug/kg) Industrial Health Based Protection of Groundwater SVOCs Acenaphthene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <931 8200 24000000 Acenaphthylene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 11000 12264000 Acetophenone <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Anthracene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 940000 122000000 Benzo(a)anthrancene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 350 8000 Benzo(a)pyrene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 96 780 Benzo(b)fluoranthene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 1200 8000 Benzo(g,h,i)perylene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 6400000 12264000 Benzo(k)fluoranthene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 12000 78000 Benzoic Acid <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 120000 1635200000 bis(2-chloroethoxy) methane <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 bis(2-chloroethyl) ether <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 0.16 5200 Bis(2-Ethylhexyl)phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 6600 410000 Bromophenylphenyl ether, 4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Butyl benzyl phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 p-Chloro-m-cresol <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Chloroaniline, 4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Chloronaphthalene, 2- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Chlorophenol, 2- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Chlorophenyl phenyl ether, 4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Chrysene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 39000 780000 NA 37000 Dibenz(a,h)anthracene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 170 780 Dibenzofuran <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 4700 1635000 Dichlorobenzidine, 3,3- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 510000 510000 Dichlorophenol, 2,4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 3.4 1000000 Diethyl phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Dimethyl phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Dimethylphenol,2,4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 640 8176000 3200000 140000 Di-n-butyl phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 4,6-dinitro-2-,methyl phenol <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Dinitrophenol, 2,4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 320000 320000 Dinitrotoluene, 2,4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 1600000 7400 7400 1600000 Dinitrotoluene, 2,6- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 1500 1500 Di-n-octyl phthalate <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 W -. .J = W-W W � a=1 18.0 7 - Table 2 Soil Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 2 of 4 Sample Identification Maximum Soil Contaminant Concentration Levels (MSCCs) Preliminary Soil Remediation Goals Analyte GTA-01 (28') GTA-02 (11') GTA-03 (22') GTA-04 (19') GTA-05 (28') GTA-06 (12') GTA-07 (12') GTA-08 (26') GTA-09 (24') GTA-10 (21') Soil -to -Water Maximum Contaminant Concentration (Soil ug/kg) Industrial/ Commercial Soil Cleanup Levels (ug/kg) Industrial Health Based Protection of Groundwater Fluoranthene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <931 290000 16400000 Fluorene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 6000000 16400000 14000000 6000000 Hexachlorobenzene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 2.6 1400 1400 2.6 Hexachlorobutadiene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 230 73000 30000 7.8 Hexachlorocyclopentadiene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 980000 980000 Hexachloroethane <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 58000 58000 Indeno(1,2,3,-cd)pyrene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 8000 Isophorone <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 210 2400000 2400000 210 Methyl naphthalene, 2- <101 <184 <117 1830 <87.2 <99.6 <103 <91.1 <920 <93.0 3600 1635000 Naphthalene <101 <184 <117 531 <87.2 <99.6 <103 <91.1 <920 <93.0 160 8176000 Nitroaniline, 2- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 1600000 1600000 Nitroaniline, 3- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Nitroaniline, 4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 120000 120000 Nitrobenzene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 22000 22000 Nitrophenol, 2- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Nitrophenol, 4- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 N-Nitrosodi-n-propyl amine <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 330 330 N-Nitrosodiphenylamine <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 470000 470000 Pentachlorophenol <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 6.5 48000 4000 Phenanthrene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 56000 12264000 Phenol <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 170 122600000 50000000 230 Pyrene <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 270000 12264000 Pyridine <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Trichlorophenol, 2,4,5- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 Trichlorophenol, 2,4,6- <101 <184 <117 <90.4 <87.2 <99.6 <103 <91.1 <920 <93.0 10 400000 VOCs Acetone 11 13.0 24.4 41.7 36.1 11.6 12.6 14.3 11.8 <920 <10.0 24000 360000000 100000000 24000 Benzene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 350 8000 5100 7.3 Bromochloromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 130000 130000 Bromodichloromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 2.9 1300 1300 2.9 Bromoform <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 26 724000 2900000 19 Bromomethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 400 570000 6000 48 Butanone, 2- (MEK) <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 Carbon Disulfide <6.03 <5.64 17.5 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 4300 40880000 700000 3800 Carbon tetrachloride <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 2.1 2900 2900 2.1 W - . .� = W-W � a=1 18.0 - Table 2 Soil Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 3 of 4 Sample Identification Maximum Soil Contaminant Concentration Levels (MSCCs) Preliminary Soil Remediation Goals Analyte GTA-01 (28') GTA-02 (11') GTA-03 (22') GTA-04 (19') GTA-05 (28') GTA-06 (12') GTA-07 (12') GTA-08 (26') GTA-09 (24') GTA-10 (21') Soil -to -Water Maximum Contaminant Concentration (Soil ug/kg) Industrial/ Commercial Soil Cleanup Levels (ug/kg) Industrial Health Based Protection of Groundwater Chlorobenzene ,6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.Oc. 440 8176000 260000 430 Chloroethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 Chloroform <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 370 180000 1400 340 Chloromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 20 440000 92000 150 cis-1,2-Dichloroethene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 350 4000000 cis-1,3-Dichloropropene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1 57000 1,2-Dibromo-3-chloropropane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 0.25 64 64 0.25 Dibromochloromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 2.1 68000 3200 1.9 Dibromoethane, 1,2- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 0.097 160 160 0.097 Dichlorobenzene, 1,2- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 230 36000000 380000 240 Dichlorobenzene, 1,4- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 99 1000000 11000 70 Dichlorobenzene,1,3- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 7600 12000000 NA 2400 Dichlorodifluoromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 210000 81760000 74000 29000 Dichloroethane, 1,1- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 32 1000000 16000 30 Dichloroethane, 1,2- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1.9 63000 2000 2 Dichloroethene, 1,1- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 350 4000000 Dichloropropane, 1,2- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 3 92000 4400 3.2 Ethylbenzene <6.03 <5.64 <5.73 335 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 4900 40000000 25000 8100 Hexanone, 2-(MBK) <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 100 2000000 260000 170 Isopropylbenzene <6.03 <5.64 <5.73 102 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1700 40880000 m&p-Xylene <6.03 <5.64 <5.73 294 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 4-Methyl-2-Pentanone (MIBK) <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 Methylene chloride <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 5.87 <5.00 20 763000 6400000 23 Methyl-t-Butyl Ether <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 91 3100000 210000 85 Naphthalene <6.03 <5.64 <5.73 1070 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 160 8176000 o-Xylene <6.03 <5.64 <5.73 155 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 Styrene <6.03 <5.64 <5.73 13.4 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1500 81760000 Tetrachloroethane, 1,1,2,2- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1 20000 Toluene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 4300 32000000 Total Xylenes <18.1 <16.9 <17.02 444 <17.0 <15.0 <15.5 <15.1 <17.6 <5.00 4600 81760000 trans-1,2-Dichloroethene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 540 8200000 trans-1,3-Dichloropropene <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1 57000 Trichlorobenzene, 1,2,3- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 Trichlorobenzene, 1,2,4- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 2600 4088000 Trichloroethane, 1,1,1- <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 1600 810000000 W -. J rar�.r•� Table 2 Soil Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 4 of 4 Maximum Soil Contaminant Preliminary Soil Remediation Sample Identification Concentration Levels (MSCCs) Goals Soil -to -Water Industrial/ Maximum Commercial Industrial Protection of Analyte GTA-01 (28') GTA-02 (11') GTA-03 (22') GTA-04 (19') GTA-05 (28') GTA-06 (12') GTA-07 (12') GTA-08 (26') GTA-09 (24') GTA-10 (21') Contaminant Soil Cleanup Health Based Groundwater Concentration (Soil Levels (ug/kg) ug/kg) Trichloroethane, 1,1,2- ,6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 2 100000 Trichlorofluoromethane <6.03 <5.64 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.00 29000 122640000 Vinyl Chloride <6.03 <16.9 <5.73 <5.23 <5.67 <5.00 <5.15 <5.05 <5.87 <5.01 0.18 4100 RCRA Metals m /k m Ika ma/ka ma/kg ma/kg mg/kg mg/kg mg/kg mg/kg Arsenic 0.4 0.87 .34 0.5 0.58 1.3 1.7 0.42 1.1 0.58 Barium 110 54 85 31 42 43 52 70 98 80 290 81000 44000 580 Cadmium 0.021 <0.12 0.13 0.033 0.065 0.04 0.046 0.063 0.14 0.07 3.0 200 200 3.0 Chromium (total) 3.1 5.1 37 1.6 4.7 10 12 4.6 3.6 2.8 5.4 1226 6.5 3.8 Chromium (VI) NA NA 0.76 NA NA 0.28 <0.5 NA NA NA 5.4 1226 6.5 3.8 Chromium (III) NA NA 36 NA NA 10 12 NA NA NA 4200 613200 350000 360000 Lead 3.8 5.9 7.6 3.4 2.5 9.3 10 4.1 6.3 2.9 270 800 800 270 Selenium 0.34 0.25 0.27 0.53 0.87 0.23 0.3 0.57 1.7 0.94 2.1 1200 1200 2.1 Silver <0.12 <0.12 <0.11 <0.11 <0.11 0.029 <0.12 <0.11 <0.12 <0.11 0.25 2044 1200 3.4 Notes: Samples collected on November 7-8, 2018 Results in micrograms per kilogram (ug/kg), or parts per billion (ppb) except where indicated. NA = Not analyzed NE = North Carolina Department of Environment and Natural Resources (NCDENR) standrd not established Blank Cell = Not analyzed Shaded and bold values represent exceedance of MDE RCS and/or ATC SVOCs = Semivolatile Organic Compounds VOCs = Volatile Organic Compounds TPH = Total Petroleum Hydrocarbons W _ . .� rar�r•� a=1 r - Table 3 Groundwater Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 1 of 4 Sample Identification GQS (pg/L) Analyte GTA-01 GTA-03 MW-1 Acetone <10.0 <10.0 <10.0 6000 Benzene <1.00 <1.00 <1.00 1 Bromochloromethane <1.00 <1.00 <1.00 Any Bromodichloromethane Bromoform <0.50 <0.50 <0.50 0.6 4 <1.00 <1.00 <1.00 Bromomethane <1.00 <1.00 <1.00 10* Butanone, 2- (MEK) <10.0 <10.0 <10.0 4000 Carbon Disulfide <10.0 <10.0 <10.0 700 Carbon tetrachloride <1.00 <1.00 <1.00 0.3 Chlorobenzene <1.00 <1.00 <1.00 50 Chloroethane <1.00 <1.00 <1.00 3000 Chloroform <0.50 <0.50 <0.50 70 Chloromethane <1.00 <1.00 <1.00 3 cis-1,2-Dichloroethene <1.00 <1.00 <1.00 70 cis-1,3-Dichloropropene <1.00 <1.00 <1.00 0.4 Cyclohexane x x x Any Dibromo-3-chloropropane, 1,2- <4.00 <4.00 <4.00 0.04 Dibromochloromethane <1.00 <1.00 <1.00 0.4 Dibromoethane, 1,2- <1.00 <1.00 <1.00 Any Dichlorobenzene, 1,2- <1.00 <1.00 <1.00 20 Dichlorobenzene, 1,4- <1.00 <1.00 <1.00 6 Dichlorodifluoromethane <1.00 <1.00 <1.00 1000 Dichloroethane, 1,1- <1.00 <1.00 <1.00 6 Dichloroethane, 1,2- <1.00 <1.00 <1.00 0.4 Dichloroethene, 1,1- x x x 350 Dichloropropane, 1,2- <1.00 <1.00 <1.00 0.6 Ethylbenzene <1.00 74.7 <1.00 600 Hexanone, 2- (MBK) <5.00 <5.00 <5.00 40* Isopropylbenzene <1.00 39.0 <1.00 70 m,p-Xylenes <2.00 37.0 <2.00 NE Methyl Acetate x x x Any Methyl, 4- Pentanone, 2- (MIBK) <5.00 <5.00 <5.00 100* Table 3 Groundwater Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 2 of 4 Sample Identification GQS (pg/L) Analyte im GTA-01 GTA-03 MW-1 Methylcyclohexane x x x Any Methylene chloride <4.00 <4.00 <4.00 5 Methyl-t-Butyl Ether <1.00 <1.00 <1.00 20 Naphthalene <1.00 110 <1.00 6 o-Xylene <1.00 <1.00 <1.00 NE Styrene <1.00 <1.00 <1.00 70 Tetrachloroethane, 1,1,2,2- <0.40 <0.40 <0.40 0.2 Tetrachloroethene <1.00 <1.00 <1.00 0.7 Toluene <1.00 <1.00 <1.00 600 Total Xylenes <3.00 37.4 <3.00 500 trans-1,2-Dichloroethene <1.00 <1.00 <1.00 100 trans-1,3-Dichloropropene <1.00 <1.00 <1.00 0.4 Trichlorobenzene, 1,2,3- <1.00 <1.00 <1.00 Any Trichlorobenzene, 1,2,4- <1.00 <1.00 <1.00 70 Trichloroethane, 1,1,1- <1.00 <1.00 <1.00 200 Trichloroethane, 1,1,2- Trichloroethene <1.00 <1.00 <1.00 0.6* 3 <1.00 <1.00 <1.00 Trichlorofluoromethane <1.00 <1.00 <1.00 2000 Tr ichlorotrifluoroethane, 1,1,2- x x x 200000 Vinyl Chloride SVOCs Acenaphthene <0.50 <10.2 <0.50 <10.1 <0.50 <10.3 0.03 80 Acenaphthylene <10.2 <10.1 <10.3 200 Acetophenone <20.4 <20.2 <20.6 700* Anthracene <10.2 <10.1 <10.3 2000 Atrazine x x x 3 Benzo(a)anthrancene <10.2 <10.1 <10.3 0.05 Benzo(a)pyrene <10.2 <10.1 <10.3 0.005 Benzo(b)fluoranthene <10.2 <10.1 <10.3 0.05 Benzo(g,h,i)perylene <10.2 <10.1 <10.3 200 Benzo(k)fluoranthene <10.2 <10.1 <10.3 0.5 Biphenyl (Diphenyl) x x x Any Biphenyl, 1,1- x x x Any Table 3 Groundwater Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 3 of 4 Sample Identification GQS (pg/L) L Analyte GTA-01 ��EL MW-1 bis(2-chloroethoxy) methane <10.2 <10.1 <10.3 Any bis(2-chloroethyl) ether <10.2 <10.1 <10.3 0.03 bis(2-chloroisopropyl) ether <10.2 <10.1 <10.3 Any Bis(2-Ethylhexyl)phthalate <10.2 <10.1 <10.3 3 Bromophenylphenyl ether, 4- <10.2 <10.1 <10.3 Any Butyl benzyl phthalate <10.2 <10.1 <10.3 1000 Caprolactam x x x 4000 Carbazole x x x 2* Chloro, 4- methyl phenol-3- x x x Any Chloroaniline, 4- <10.2 <10.1 <10.3 Any Chloronaphthalene, 2- <10.2 <10.1 <10.3 Any Chlorophenol, 2- <10.2 <10.1 <10.3 Any Chlorophenyl phenyl ether, 4- <10.2 <10.1 <10.3 Any Chrysene <10.2 <10.1 <10.3 5 Dibenz(a,h)anthracene <10.2 <10.1 <10.3 0.005 Dibenzofuran Dichlorobenzidine, 3,3- <5.10 <5.05 <5.15 28* <10.2 <10.1 <10.3 Any Dichlorophenol, 2,4- <10.2 <10.1 <10.3 0.98* Diethyl phthalate <10.2 <10.1 <10.3 6000 Dimethyl phthalate <10.2 <10.1 <10.3 Any Dimethylphenol, 2,4- <0.51 <0.51 <0.52 100 Di-n-butyl phthalate <10.2 <10.1 <10.3 Any dinitro, 4,6- methyl phenol,2- <51.0 <50.5 <51.5 Any Dinitrophenol, 2,4- <51.0 <50.5 <51.5 Any Dinitrotoluene, 2,4- <10.2 <10.1 <10.3 Any Dinitrotoluene, 2,6- <10.2 <10.1 <10.3 Any Di-n-octyl phthalate <10.2 <10.1 <10.3 100 Fluoranthene <10.2 <10.1 <10.3 300 Fluorene <10.2 <10.1 <10.3 300 Hexachlorobenzene <1.02 <1.01 <1.03 0.02 Hexachlorobutadiene <10.2 <10.1 <10.3 0.4 Hexachlorocyclopentadiene <10.2 <10.1 <10.3 Any Hexachloroethane <10.2 <10.1 <10.3 Any WMm ■. R--&.'M Table 3 Groundwater Analysis Summary Glenwood Two Raleigh, North Carolina GTA Project No. 35151659 Page 4 of 4 Sample Identification GQS (pg/L) L Analyte GTA-01 GTA-03 MW-1 Indeno(1,2,3,-cd)pyrene <10.2 <10.1 <10.3 0.05 Isophorone <10.2 <10.1 <10.3 40 Methyl naphthalene, 2- <10.2 21.0 <10.3 30 Methylphenol, 2- x x x 400* Methylphenol, 3&4- x x x 440 Naphthalene <5.10 37.3 <5.15 6 Nitroaniline, 2- <20.4 <20.2 <20.6 Any Nitroaniline, 3- <20.4 <20.2 <20.6 Any Nitroaniline, 4- <20.4 <20.2 <20.6 Any Nitrobenzene <10.2 <10.1 <10.3 Any Nitrophenol, 2- <10.2 <10.1 <10.3 Any Nitrophenol, 4- <51.0 <50.5 <51.5 Any N-Nitrosodi-n-propyl amine <10.2 <10.1 <10.3 Any N-Nitrosodiphenylamine <10.2 <10.1 <10.3 Any Pentachlorophenol <20.4 <20.2 <20.6 0.3 Phenanthrene Phenol <10.2 <10.1 <10.3 200 <10.2 <10.1 <10.3 30 Pyrene <10.2 <10.1 <10.3 200 Pyridine <10.2 <10.1 <10.3 Any Trichlorophenol, 2,4,5- <10.2 <10.1 <10.3 63* Trichlorophenol, 2,4,6- <10.2 <10.1 <10.3 4* Notes: Samples collected November 7-8, 2018 Results in micrograms per liter (pg/L), or parts per billion (ppb) "<x.xx" = Not detected at or above the indicated laboratory reporting limit NE = North Carolina Department of the Environment and Natural Resources (NCDENR) standard not established Blank Cell = Not analyzed NCDENR Groundwater Quality Standard (GQS) (15A NCAC 02L .0202) * = GQS is an interim maximum allowable concentration (IMAC) established under 15A NCAC 02L .0202. Shaded and bold values represent exceedance of the GQS SVOCs = Semi -volatile Organic Compounds VOCs = Volatile Organic Compounds r ■ . Table 4 Glenwood Two Raleigh, North Carolina Soil Vapor Analysis Summary GTA Project No.35151659 Page 1 of 2 Sample Identification Sub -Slab Analyte j1GTA-Sv_1 GTA-SV-2 GTA-SV-3 GTA-SV-4 GTA-SV-6 SVISL Commercial VOCs Acetone <24 43 26 24 <24 2,700,000 AIIyl chloride <1.6 <1.6 <1.6 <1.6 <1.6 88 Benzene 0.96 1.6 3.8 <0.80 8.6 1,600 Benzyl chloride <2.6 <2.6 <2.6 <2.6 <2.6 88 Bromodichloromethane <3.3 <3.3 <3.3 <3.3 <3.3 330 Bromoethene <2.2 <2.2 <2.2 <2.2 <2.2 NE Bromoform <5.2 <5.2 <5.2 <5.2 <5.2 11,000 Bromomethane <1.9 <1.9 <1.9 <1.9 <1.9 440 Butadiene, 1,3- <1.1 <1.1 <1.1 <1.1 <1.1 180 Carbon disulfide <31 <31 <31 <31 <31 61,000 Carbon tetrachloride <3.1 <3.1 <3.1 <3.1 <3.1 2,000 Chlorobenzene <2.3 <2.3 <2.3 <2.3 <2.3 4,400 Chloroethane (Ethyl Chloride) <1.3 <1.3 <1.3 <1.3 <1.3 880,000 Chloroform <2.4 <2.4 <2.4 <2.4 <2.4 530 Chloromethane <1.0 <1.0 <1.0 <1.0 <1.0 7,900 Cyclohexane <1.7 <1.7 <1.7 <1.7 12 88,000 Dibromochloromethane <4.3 <4.3 <4.3 <4.3 <4.3 NE Dibromoethane, 1,2- <3.8 <3.8 <3.8 <3.8 <3.8 20 Dichlorobenzene, 1,2- <3.0 <3.0 <3.0 <3.0 <3.0 18,000 Dichlorobenzene, 1,3- <3.0 <3.0 <3.0 <3.0 <3.0 NE Dichlorobenzene, 1,4- <3.0 <3.0 <3.0 <3.0 <3.0 1,100 Dichloroethane, 1,1- <2.0 <2.0 <2.0 <2.0 <2.0 7,700 Dichloroethane, 1,2- <2.0 <2.0 <2.0 <2.0 <2.0 470 Dichloroethene, 1,1- <2.0 <2.0 <2.0 <2.0 <2.0 18,000 Dichloroethene, cis-1,2- <2.0 <2.0 <2.0 <2.0 5.5 NE Dichloroethene, trans-1,2- <2.0 <2.0 <2.0 <2.0 <2.0 NE Dichloropropane, 1,2- <4.6 <4.6 <4.6 <4.6 <4.6 350 Dichloropropene, 1,3- <2.3 <2.3 <2.3 <2.3 <2.3 1,800 Dioxane, 1,4- <9.0 <9.0 <9.0 <9.0 <9.0 130,000 Ethyl acetate <1.8 <1.8 <1.8 <1.8 <1.8 6,100 Ethylbenzene <1.1 <1.1 <1.1 <1.1 3.9 4,900 Ethyltoluene, 4- <2.5 <2.5 <2.5 <2.5 <2.5 NE Freon 11 (Trichlorofluoromethane) <2.8 <2.8 <2.8 2.9 <2.8 NE Freon 113 (Trichlorotrifluoromethane) <3.8 <3.8 <3.8 <3.8 <3.8 NE Freon 114 (1,2-Dichloro-1,1,2,2-tetrafluoroethane) <3.5 <3.5 <3.5 <3.5 <3.5 NE Freon 12 (Dichlorodifluoromethane) <2.5 2.5 <2.5 <2.5 2.6 8,800 Heptane <2.0 <2.0 <2.0 <2.0 32 35,000 Hexachloro-1,3-butadiene <5.3 <5.3 <5.3 <5.3 <5.3 560 Hexane <35 <35 <35 <35 38 61,000 Methyl Butyl Ketone (2-Hexanone) <5.1 <5.1 <5.1 <5.1 <5.1 2,600 Methyl Ethyl Ketone (2-Butanone) <3.7 13 13 11 13 440,000 Methyl Isobutyl Ketone <5.1 <5.1 <5.1 <5.1 <5.1 260,000 Methyl tert-butyl ether <0.90 <0.90 <0.90 <0.90 <0.90 47,000 Methylene chloride <36 <35 <35 <35 <35 53,000 Naphthalene <1.3 <1.3 <1.3 <1.3 <1.3 260 Propylene <4.3 <4.3 <4.3 <4.3 580 260,000 Styrene <11 <11 <11 <11 <11 88,000 Tetrachloroethane, 1,1,2,2- <3.4 <3.4 <3.4 <3.4 <3.4 210 Mi." 61 �� Table 4 Glenwood Two Raleigh, North Carolina Soil Vapor Analysis Summary GTA Project No.35151659 Page 2 of 2 Sample Identification Sub -Slab GTA-SV-1 GTA-SV-2 GTA-SV-3 GTA-SV-4 GTA-SV-6 SVISL Commercial Tetrachloroethylene <3.4 5.8 87 <3.4 7.5 3,500 Tetrahydrofuran <1.5 1.8 <1.5 <1.5 <1.5 NE Toluene 1.2 1.4 1.0 1.3 8.0 440,000 Trichlorobenzene, 1,2,4- <3.7 <3.7 <3.7 <3.7 <3.7 180 Trichloroethane, 1,1,1- <2.7 <2.7 <2.7 <2.7 <2.7 440,000 Trichloroethane, 1,1,2- <2.7 <2.7 <2.7 <2.7 <2.7 180 Trichloroethene <2.7 <2.7 20 4.2 7.9 180 Trimethyl benzene, 1,2,4- <2.5 <2.5 3.6 <2.5 <2.5 5,300 Trimethyl benzene, 1,3,5- <2.5 <2.5 <2.5 <2.5 <2.5 5,300 Trimethylpentane, 2,2,4- <2.3 <2.3 <2.3 <2.3 70 NE Vinyl acetate <1.8 <1.8 <1.8 <1.8 <1.8 18,000 Vinyl bromide <2.2 <2.2 <2.2 <2.2 <2.2 260 Vinyl chloride <1.3 <1.3 <1.3 <1.3 <1.3 2,800 Xylene, m&p- <2.2 <2.2 <2.2 <2.2 2.5 8,800 Xylene, o- <1.1 <1.1 <1.1 <1.1 1.1 8,800 Notes: Samples collected on November 7, 8, and 9, 2018 Results expressed in micrograms per cubic meter (Ng/m3) SVISL = NCDEQ Soil Vapor Intrusion Sreening Levels, dated February 2018 VOCs = Volatile Organic Compounds NE = No published guidance value W . " ATTACHMENT E SAMPLE LOCATION PLAN HILLSBOROUGH STREET .709 701 _ SBD-9 '�`� �-�� • J SBD-10 ` GTA-69SBD-8 SBD-11 SBD-12 SBA-7 MV-1 �• GTA-SV-5 . " GTA-08 Ui Q 7 J GTA-07 Z SBD-13 Q " GTA-06 , 0 ETA-10 GTA-05 + m r .' SBD-5 2 F- "t SBD-6 SBD-4 0 Approximate Subject Property Boundaries r � bay � _ 4 WEST MORGAN STREET 630 HILLSBORC 623 621 SBD-2 SBD-3 -` $GTA-04 SBD-1 - �-- �_. - " GTA -.. -SV-2 GTA-SV-1 GTA-SV-3 � } GTA-03 t G_TQ-02 - GTAf1 +jo-r V-4 L -r ti s ! r� — ' AL r � L e 4 a_IFF . IL+ #� �.- Identification and approximate location of soil borings GTA-01 performed by GTA in November 2018. Identification and approximate location of soil vapor GTA- SV-1 samples collected by GTA in November 2018. & Identification and approximate location of existing MW-1 monitoring well. Identification and approximate location shallow soil SBD-1 delineation borings installed by GTA in November 2018. 0 25 50 Approximate Scale 1 inch = 50 feet