Loading...
HomeMy WebLinkAbout18067_Wurst Property_O_20160610"A PEAK Engineering & Design June 10, 2016 Mr. Mike Deaton Town of Apex Environmental Programs Manager P.O. Box Apex, NC 27502 P (919) 249-3413 Michael. Deatonggpexnc.org Re: 810 Lufkin Road Apex, NC Peak Engineering & Design has completed the preliminary Storm Water Analysis for the aforementioned project and has quantified the storm water requirements for the property in the enclosed submittal. This analysis includes the pre and post development runoff from the site, the 10% confluence point downstream of the property and the overall project concept. After review of the available data and preparation of the Minor Site Plan, the project has been identified to not have any negative impacts on the downstream storm water infrastructure, homes or businesses. The prevention of impacts to downstream stormwater will be accomplished by an overall reduction of impervious surface on the property, approximately 2,664 sf. Maintaining current drainage patterns and discharge rates. As a result, stormwater control devices are not required. The property is approximately 16 acres. While the overall drainage area to the onsite stream is approximately 290 acres. Showing the property to contribute approximately 5.5% of the overall drainage area. If you have any questions concerning the enclosed information, do not hesitate to contact our office. Sincerely, a Ii Daniel H. Woods, P.E. Peak Engineering & Design, PLLC 810 Lulkin Road —Apex, NC 0\\11I 1/l/��i a SEAL 9r; 032616 919.439.0100 p 919.4:39.6411 f iroach('Wpeaakengineed ngdesigyn. coin S448 Apex Peak\Nay 4368 II Apex. NC 27502 www.PeakEngineeringDesign.com Page 1 of 2 ACME Planimeter Measure areas using Google Maps! Drag the map with your mouse, or double-click to center. Click on the map to place points. The enclosed area is shown below. 1.172e+6 m2 / 117.2 hectares / 1.172 km2 / 1.261 e+7 ft2 / 289.6 acres / 0.4525 mile http://acme.com/planimeter/ 6/ 1 /2016 Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. 12 inch Driveway Crossing Pipe Circular Diameter (ft) = 1.00 Invert Elev (ft) = 413.02 Slope (%) = 1.37 N-Value = 0.013 Calculations Compute by: Known Q Known Q (cfs) = 2.90 414.50 414.00 413.50 413.00 412.50 1 Highlighted Depth (ft) Q (cfs) Area (sqft) Velocity (ft/s) Wetted Perim (ft) Crit Depth, Yc (ft) Top Width (ft) EGL (ft) Section 2 Friday, Jun 10 2016 = 0.62 = 2.900 = 0.51 = 5.66 = 1.81 = 0.73 = 0.97 = 1.12 Depth (ft) .98 1.48 Kim 0.48 -0.02 -0.52 3 Reach (ft)