Loading...
HomeMy WebLinkAbout08022_Reeves_EMAIL_Doby Creek Water Line 20180313From:Wolfe, David To:Minnich, Carolyn Subject:[External] Former Reeves / Polymer Centers (BF# 08022-04-060) Date:Tuesday, March 13, 2018 9:38:51 AM Attachments:Pages from DOBY CRK 32423-000 SIGNED 12-13-2017.pdf CAUTION: External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to Report Spam. Hi Carolyn – this is mostly fyi but call me if you think we should discuss. Later this year Charlotte Water will be upgrading the sewer line along Doby Creek, at back of this site. They called me to discuss the project. The sewer line is outside the known plume of soil or groundwater contamination. Charlotte Water has the BFA and reviewed the LUR’s for this site, and don’t believe they will be in any conflict. This sewer line is to support continued development (including new Brownfield sites!) in the northeast part of Charlotte, along the new light rail line. We spoke about this site last year for a bridge over I-85 project. That project is still in design. David Wolfe, P.E., ENV SP PROGRAM MANAGER ENVIRONMENTAL SERVICES ENGINEERING & PROPERTY MANAGEMENT City of Charlotte, NC Cell: 704 / 577-8611 We appreciate customer feedback. Please click here to take a short survey. From: LeBlanc, Ryan Sent: Friday, March 09, 2018 10:11 AMTo: Wolfe, DavidSubject: Doby Gravity Sewer Plans See attached. Ryan F. LeBlanc, PE / Engineering Project ManagerCHARLOTTE WATER 5100 Brookshire Blvd. / Charlotte, NC 28216 P:704-391-5151 / C:980-259-9439 / charlottewater.org CACACACA0 2016 AERIAL PHOTOGRAPHY 100 200 SCALE: 1" = 100' 50100 FES DCB DCB DCB FES MH CB CB CB CB CB CB DI DI FES MH MHDI DIDICBCBFESFES RE MO VEREMOVE REMOVE REMOVEREMOVE REMOVERETAINRETAINRETAIN RETAIN RETAINRETAINRETAIN RETAIN RETAINRETAIN RETAINRETAINRETAINRETAINRETAIN RETAINRETAINRETAIN RETAIN RETAIN RETAIN RETAIN RETAINRE TAIN RETAINHW DIDIDI15" RCP 15" RCP 30" RCP 30" RCP 30" RCP 30" RCP 15" RCP15" RCP15" RCP15" RCP24" RCP 15" RCP18" RCP 18" RCP 15" RCP 30" RCP 15" RCP 15" RCP 15" RCP 15" RCP 18" RCP 18" RCP 15" RCP 15" RCP15" RCP 30" RCP LIMIT OF CONSTRUTION - CUT LIMIT OF CONSTRUTION - FILL LEGEND MONITORING WELL INTERSTATE 85 ROW 68' DUKE EXISTING DUKE ENERGY TRANSMISSION LINEEXISTING SANITARY SEWER LINEI-85 NBI-85 SBTO MALLARD CREEK CHURCH RDTO W.T. HARRIS BLVDRETAINING WALL PROPOSED RETAINING WALL PROPOSED 8921 RESEARCH DR HEWLETT-PACKARD 9014 RESEARCH DR 1000 LOUIS ROSE PL LOUIS ROSE PL POLYMERS CENTER OF EXCELLENCE, INC 8900 RESEARCH DR DOBY CREEK100-YEAR FLOODPLAIN MALLARD CREEK POLYMERS, INC 8901 RESEARCH DR TIAA / GO HEALTH RESEARCH DRTWO BRIDGES CURRENTLY SHOWN. OVER I-85 AND DOBY CREEK INSTEAD OF THE LONGER BRIDGE COULD BE CONSTRUCTED CROSSING DOBY CREEK OR ONE SINGLE LARGE BOX CULVERT COULD BE CONSTRUCTED THE DESIGN PROGRESSES. IT IS POSSIBLE A SOME CHANGES COULD BE INCORPORATED AS CREENWAY DOBY CREEK POSSIBLE CONNECTION TO FUTURE W TERW TERW TERW TERHAZEN AND SAWYER9101 SOUTHERN PINE BLVD, SUITE 250CHARLOTTE, NORTH CAROLINA 28273LICENSE NO. : C-0381NOTES:1. PROVIDE TEMPORARY BYPASS PUMPING AS NEEDED TOCOMPLETE NEW TIE-IN CONNECTIONS AND INSTALLNEW SANITARY SEWER. REFER TO SPECIFICATIONSECTION 02665.2. NEW SANITARY SEWER SHALL BE INSTALLED WITH ATRACER WIRE PER SANITARY SEWER TRACER WIREINSTALLATION DETAIL ON DWG D4 AND INACCORDANCE WITH SPECIFICATION SECTION 15000.68' DUKE ENERGYEASEMENTEXIST GRADE68' DUKE ENERGYEASEMENTPPPPPPPPPPPPPPPPPPPPASPHALT PARKINGEXIST 20'EASEMENTEXIST 15'EASEMENT20' PERMANENT EASEMENTWETLAND W1WETLAND W2WETLAND W5POLYMER CENTER OFEXCELLENCE, INCDEED REF: 21580-923TAX PARCEL NO. 04714103A/BEXIST 20'EASEMENT20' PERMANENTEASEMENT40'35'MONITORINGWELL4PROPOSED 36" DIP W TERW TERW TERW TERHAZEN AND SAWYER9101 SOUTHERN PINE BLVD, SUITE 250CHARLOTTE, NORTH CAROLINA 28273LICENSE NO. : C-0381NOTES:1. PROVIDE TEMPORARY BYPASS PUMPING AS NEEDED TOCOMPLETE NEW TIE-IN CONNECTIONS AND INSTALLNEW SANITARY SEWER. REFER TO SPECIFICATIONSECTION 02665.2. NEW SANITARY SEWER SHALL BE INSTALLED WITH ATRACER WIRE PER SANITARY SEWER TRACER WIREINSTALLATION DETAIL ON DWG D4 AND INACCORDANCE WITH SPECIFICATION SECTION 15000.3. CONTRACTOR SHALL NOT USE EXISTING CONCRETEBRIDGE FOR ACCESS.EXIST GRADE68' DUK E ENERGY EASEMENT EXIST 20'EASEMENTPPPPPPPPPPPPASPHALT PARKINGASPHALT DRIVE20' PERMANENT EASEMENT40'POLYMER CENTER OFEXCELLENCE, INCDEED REF: 21580-923TAX PARCEL NO.04714103A/BTHE GC NET LEASE(CHARLOTTE RESEARCH) INVESTORS, LLCC/O GRIFFIN CAPITAL CORPORATIONDEED REF: 29634-996TAX PARCEL NO. 0471410740'EXIST 20'EASEMENT25' PERMANENT EASEMENT15' PERMANENT EASEMENT20' PERMANENTEASEMENTPROPOSED 36" DIP