Loading...
HomeMy WebLinkAbout14040_Union Carbide_Receptor SurveyPage 1 of 5 General Instructions 1.) 2.) 3.) Site:CSX Intermodal Yard Expansion Address:5400 Hovis Road City:Charlotte County:Mecklenburg Section 1 - Property Characteristics 17.3 30 30 0 0 0 0 0 70 70 Section 2 - Surrounding Properties BROWNFIELDS AREA RECONNAISSANCE AND RECEPTOR SURVEY GUIDANCE FORM Provide Information for the following potential receptors Current Usage Proposed Usage This form was created to facilitate the preparation of a receptor survey for a given brownfield property. This is a guidance document only, and Prospective Developers may complete and submit their own receptor survey, if they desire. Any receptor survey submitted must be completed by a qualified environmental professional. Complete "Property Characteristics" Section and all portions of other sections where an "X" has been placed in the far left column under “Applicable to Site,” as determined by the DENR Brownfields Project Manager on a site specific basis. % of property that is agricultural crops % of property that is barren % of property that is used for commercial or industrial usage including paved areas % of property that is scrub/shrub % of property that is open land The search-radius distances to potential receptors from the Property boundary will be determined by the DENR Brownfields Project Manager on a site by site basis. Search-radius distances are measured from the site Property Boundary unless otherwise indicated by the DENR Brownfield’s Project Manager. Size of Property (acres) % of property that is wooded % of property that is grass area Rev. 06/05/02 Page 2 of 5 X North I-2 Industrial (general) X South I-2 Industrial (general) X East I-2 Industrial (general) X West I-2 Industrial (general) Proposed Zoning/Land UseApplicable to Site (DENR Use Only) Direction from Subject Brownfield Property Current Zoning/Land Use Rev. 06/05/02 Page 3 of 5 Section 3 - Potential Receptors - include burial depth, construction material and diameter, when available. Distance Direction Depth X Is a basement or subsurface foundation within 1000 ft of the Property boundary?N Y 12/29/2010 X Is a school or daycare center within 1000 ft of the Property boundary?N Y 12/29/2010 X Is a storm sewer within 1000 ft of the Property boundary? Y Y 12/29/2010 0 West 2 feet X Is a sanitary sewer within 1000 ft of the Property boundary? Y Y 12/29/2010 0 West, East, South unknown X Is a septic system leach field within 1000 ft of the Property boundary?N N 1/5/2011 X Is a water line main within 1000 ft of Property boundary? Y Y 12/29/2010 0 West unknown X Is a natural gas line main within 1000 ft of the Property boundary? Y Y 12/29/2010 0 West/SW unknown X Is a buried telephone/ cable main within 1000 ft of the Property boundary?Y Y 12/29/2010 0 West unknown X Is a buried electrical cable main within 1000 ft of Property boundary?N Y 12/29/2010 Section 4 - Local Water Supply Public:X Private: Potable Water Supplier Name:Charlotte-Mecklenburg Utilities Potable Water Supply Source:Mountain Island Lake (Catawba River) Distance:5 miles Direction:Northwest Potable Water Source Intake:Charlotte Reservoir (5200 Brookshire Blvd) Distance:0.5 miles Direction:North Complete and attach map as appropriate Applicable to Site (DENR Use Only) Provide Information for the following potential receptors Y/N Field Verified Date Verified Rev. 06/05/02 Page 4 of 5 Section 5 - Water Supply Wells Distance Direction Depth X Is a public water supply well within 1 mile of the Property boundary?N N 12/29/2010 X Is a private water supply well within 1/2 mile of the Property boundary?Y Y 12/29/2010 800 feet North unknown X Is a irrigation supply well within 1/2 mile of the Property boundary?N N 12/29/2010 X Is a monitoring well within 1500 ft of the Property boundary? Y Y 12/29/2010 600 feet West unknown Section 6 - Water Bodies on Property X Is water body naturally developed or man made? NA X List the uses of the water body NA X What is the source of the water for the water body NA X What is the nature of the bottom of the water body (e.g., rocky or concrete bottom, drainage ways or impoundments)NA X Are there any wetlands present on the property? No Applicable to Site (DENR Use Only) Provide Information for the following potential receptors Comments Complete and attach map as appropriate Applicable to Site (DENR Use Only) Field Verified Date Verified Provide Information for the following potential receptors Y/N Rev. 06/05/02 Page 5 of 5 Section 7 - Surface Water Body Distance Direction Depth X Are there surface waters located within 500/1000 ft of the Property boundary?Y N/A Stream on-site East Unknown Additional water bodies, if needed Section 8 - Additional Requests/ Observations Did not send letters to surrounding properties. Applicable to Site (DENR Use Only) Provide Information for the following potential receptors Comments Complete and attach map as appropriate Applicable to Site (DENR Use Only) Provide Information for the following potential receptors Y/N Name Type Rev. 06/05/02 ???? ? ?!!!!!!è !è !è !ã !ã !( !(Monitoring Well !ã Water Supply Well !è Sanitary Sewer Manhole Sanitary Sewer Pipeline !Water Main Surface Water ?Surface Water (Approx.) Road 0.5 Mile Buffer 1,500 Ft. Buffer 1,000 Ft. Buffer Parcel Boundary ³Hovis RoadBroo k s h i r e B o u l e v a r d Ro z z e l l e s F e r r y R o a d Nor t h C a r o l i n a 1 7 8 4 700 Feet Figure DR: W. Blaylock CHK: K. Watkins DATE: 01/07/2011 RECEPTOR SURVEY MAP 1CLIENT: PROJ.: 643008041 TITLE: SCALE: 1" = 700'SITE:FORMER UNION CARBIDE PROPERTYBROWNFIELDS PROJECT NUMBER: 14040-10-605400 HOVIS ROADCHARLOTTE, NORTH CAROLINA AMEC Earth & Environmental2200 Gateway Centre Blvd., Suite 205Morrisville, NC 27560(919) 447-2750 P:\ProjectFiles\643008041_CSX Hovis Road\GIS\Mxds\Wells.mxd