Loading...
HomeMy WebLinkAboutSW3190701_Supplement EZ Form_20190927SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Shop Addition- Harwood Automotive 2 Project Area aC 4.94 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 0.17 5 Is this project High or Low Densi3 ? High 6 1 Does this project use an off -site SCM? No COMPLIANCE WITH 02M.1003(4) 7 Width of vegetated setbacks provided feet 101+ 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003 4 ad out of the setback? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMS: 11 Infiltration Sy stem 0 12 t3ioretention Cell 0 13 Wet Pond 0 14 Slormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 Stom liter 0 24 Silva Cell 0 25 Ha filter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and THIe: Mitchell Laatham P.E. President 28 Organization: Latham -Walters Engineering, Inc. 29 Street address: 16507-A Northcross Drive 30 City,, State, Zip: Huntersvilla NC 28078 31 Phone numbers ; 704-895-8484 32 Email: mitch@lwengineer.com C—ediTilpatQn.Statemeft I certify, under penalty of law that this Supplemort-FZ form and all supporting information were prepared under my direction or supervision. that the information provided In the form is, to the best of my knowledge and belief, true, accurate, and complete: and that the ergineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Ali i SEAL. 17'646 Gil S. Signature of Designer use DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Sand Filter 5 Total BUA in project (sq ft 47307 sf 16527 sf 6permitting) New BUA on subdivided lots (subject to s ft 7permitting) New BUA outside of subdivided lots (subject to sf 8868 sf 8868 sf 8 JOffsite - total area (sq ft 74874 sf 11305 sf 9 Offsite BUA (sq ft 0 sf 0 sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 7267 sf 7267 sf Sidewalk (sq ft Roof (sq ft 1601 sf 1601 sf Roadway s ft Future (sq ft Other, please specify in the comment box below (sq ft 11 New infiltrating permeable pavement on subdivided lots (sq ft sf 12 New infiltrating permeable pavement outside of Isubdivided lots (sq ft 13 Exisitng BUA that will remain (not subject to ermittinq) (sq ft 38439 sf 7982 sf 14 Existing BUA that is already permitted (sq ft 0 sf 0 sf+ 15 Existing BUA that will be removed (sq ft 16 Percent BUA 21.98% 32.28% 17 Design storm inches 1 in 18 IDesiqn volume of SCM cu ft 1092 cf 19 Calculation method for desi n volume Simple DDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM N/A Sand Filter 5 Total BUA from project (sq ft) 6 1995 rules SL 2006-246 2008 rules 2017 rules 7 New BUA on subdivided lots (subject to permitting) (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules New BUA outside of subdivided lots (subject to permitting) (sf) 1995 rules SL 2006-246 8 2008 rules 2017 rules 9 Offsite - total area (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 10 Offsite BUA (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 11 Design storm (inches) 1995 rules SL 2006-246 2008 rules 2017 rules 12 Breakdown of new BUA: Parking (sq ft Sidewalk (sq ft Roof (sq ft Roadway s ft Future (sq ft Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on subdivided lots (sq ft 14 New infiltrating permeable pavement outside of subdivided lots (sq ft 15permitting) Exisitng BUA that will remain (not subject to s ft 16 Existing BUA that is already permitted (sq ft 17 Existing BUA that will be removed (sq ft 18 Percent BUA 19 Desi n volume of SCM cu ft 20 Calculation method for design volume ADDITIONAL INFORMATION 21 Please use this space to provide any additional information about the drainage area(s): SAND FILTER 18 SHWT elevation (fmsl) < 522.5 19 Type of sand filter (open or closed) Open 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 3045 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber (fmsl) 526.00 26 Area of the sediment chamber (square feet) 742 sf 27 Physical depth of the sediment chamber (inches) 24" 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 24" 29 Elevation of top of weir between chambers (fmsl) 528 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) Bottom of the sand chamber (fmsl) 1339 cf 31 523.50 32 Area of the sand chamber (square feet) 180 sf 33 Physical depth of the sand chamber (inches) 30" 34 Ponding depth in the sand chamber, above any permanent pool (inches) 12" 35 Elevation of the bypass device (fmsl) 527 36 Type of bypass device Weir 37 Mechanism for distributing flow over the sand surface Rock Weir 38 Sand specification for sand chamber ASTM C-33 39 Depth above underdrain pipe (inches) 18 in Will the media be maintained to drain at least two inches per hour at the sand surface? Yes L42O Is at least one clean -out pipe provided at the low point of each underdrain line? Yes Will clean -out pipes be capped? Yes Sand Filter 1 11:26 AM 9/27/2019