Loading...
HomeMy WebLinkAboutNCG030672_MONITORING INFO_20190318STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. � Cl� D 3 O DOC TYPE ❑ H ORICAL FILE ONITORING REPORTS DOC DATE ❑ � "� 05 YYYYMMDD 0--m M-Nal.-C-0, ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. March 11, 2019 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: RECEIVED MAR 18 2019 Phone: 1-910-944-3355 Fax:1-910-944-3418 www.eHco.com Please find enclosed the Discharge Monitoring Report (DMR) for February 2019 for the ERICO facility referenced above. If you have any questions, please do not hesitate to call me at (910)-944-4127. Sincerely, Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8976 8953 CADDY® • ERICO® • ERlFLEX® • ERITECN® • LENTON® OMICROBAC" Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K9B0238 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Road Received: 02/19/2019 Aberdeen, NC 28315 Reported: 03/08/2019 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Lague Lab Sample ID: K9130238-01 Collection Date: 02/16/2019 8:50 Wet Chemistry Result RL Units Note Method: EPA 1664 Rev. B Oil & Grease (SG I -HEM) <5.00 5.00 mg/L Al2 Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+13-2011 pH at 25 °C <4.17 4.17 mg/L 5.8 1.0 pH Units H Prepared Analyzed Analyst 03/06/19 0922 TAB 02/20/19 0945 MT 02/21/19 1142 CLB Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Lead <0.005 0.005 mg1L 02/21/19 1551 02126/191130 TAB Zinc 0.054 0.002 mg/L 02/21/19 1551 02/26/19 1130 TAB Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst Method: EPA200.7 Copper, Total 0.176 0.00500 mg/L 02/25/19 0647 02/25/19 1853 LSJ Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 VMICROBAC'!L' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K9B0238 Client Sample ID: Storm Water 02, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K9130238-02 Collection Date: 02/1912019 8:58 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 'C Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mg1L 03106h9 0922 TAB <4.17 4.17 mglL 4.9 1.0 pH Units H 0212009 0945 MT 02/21119 1142 CLB Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals AqueouslEPA 200.7 Rev 4.4 1994 Lead <0.005 0.005 mg/L 02121/19 1551 02/261191130 TAB Zinc 0.154 0.002 mg/L 02/21/19 1551 02/26119 1130 TAB Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst Method: EPA200.7 Copper, Total 1.53 0.00500 mg1L 02125/19 0647 02/25119 1857 LSJ Definitions Al2: MSlMSD fail recovery, but the LCS passes criteria. H; Analyte was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. Reviewed and Approved By: Jeanne Overstreet Client Relationship Specialist, Environmental Reported: 03/08/2019 16:58 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 0N1fCROBAC' Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-1920 / 8( `K9B0238- CHAIN OF CUSTODY RECORD F.. CLIENT NAME BADDRESS, nVent 188 Carolina Road Pox 0396910 PROJECT I LOCATION: "Feb. 19" Stormwater Sampling J F O LL O TYPE OF ANALYSIS PRESERVATION CODE N a V Cn co CODE: A = None B = HNO3 (pH<2) + <6'C C = H2SO4 (pH<2) + <6'C D = NaOH + <6°C E = ZN Acetate + <6"C F = HCi G = Sodium Thio CONTACT PERSON: Mark Logue EMAIL: mark.lo ue nvent.corn SAMPLED BY: Frank Bryant PHONE NUMBER: 910-9444127 DATE J METHOD OF SHIPMENT: Picked up by Microbac/Ice LAB ID rx SAMPLE TYPE DAiE COMP GRAB PH Flow TEMP'C CHt�- suLFiDE 01 Storm Water, 01 � !y cJTIME 5 X 4 B A A C �-•� 02 Storm Water, 02 ✓Z /� X 4 B A A C I Lab Initials urkjLdShed by` Date Rene afore) Date11 lei /�i kEll 2 eu J Date �/ ��/' me "� Z S ed ref Date 3 7 L 4 Relin hed by: Date tme ecelred by: (Signature) ate Time 51 6 Turnaround time: REGULAR RUnVIEViI Lv Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3of3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _March 11, 2019 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 Comments on sample collection or analysis:_ Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' February (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2/16/19 0.6 <4.17 5.8 0.176 <0.005 0.054 <5.00 N/A Outfall #2 2/16/19 0.6 <4.17 4.9 1.53 <0.005 0.154 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Mana er Alature) t titl 0 A Lk' 03/11/2019 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _February 26 _20_19 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_Microbac Fayetteville lab Cert. # 11 Comments on sample collection or analysis:— Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' January_ month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other RE F1�fF D PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 MAR 0 4 2019 MAfti {��L _ - ❑ No discharge this period?' f?1fti7 c,-r FlLE4' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches s Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 1/24/19 0.4 5.50 5.3 0.528 <0.005 0.095 <5.00 N/A Outfall #2 1/24/19 0.4 <4.17 3.5 0.180 <0.005 0.050 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as fourid in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit.. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Manager Title Prin ti le) 42/26/2019 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. pate Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 - 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-14/31/2017 SWU-245, last revised 10/2S/2012 Page 2 of 3 0MICROBAC' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K9A0364 Erlico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Road Received: 01/25/2019 Aberdeen, NC 28315 Reported: 02/08/2019 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K8A0364-01 Collection Date: 01/24/2019 5:00 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (5GT-HEM) Method: 5M 2540 0-2011 Total Suspended Solids Method: SM 4500 H+8-2011 pH at 25 °C Result RL Units <5.00 5.00 mglL 5.50 4.17 mglL Note Prepared Analyzed Analyst 01/31/19 1104 TAB 5.3 1.0 pH Units H 01/30/19 0944 MT 01/28/19 1447 DC Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Copper 0,528 0.025 mg1L 02/06/19 1233 02/06119 1233 TAB Lead <0.005 0.005 mg1L 02/06119 1233 02/06/19 1233 TAB Zinc 0.095 0.002 mg/L 02/06119 1233 02/06/19 1233 TAB Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 VMICROBAC. Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K9A0364 Client Sample ID: Storm Water 02, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K9A0364-02 Collection Date: 01/24/2019 5:00 Wet Chemistry Result RL Units Note Prepared Analyzed Analyst Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) <5.00 5.00 mglL Al2 01/31/19 1104 TAB Method: SM 2540 D-2011 Total Suspended Solids <4A7 4.17 mglL 01/30/19 0944 MT Method: SM 4500 H+B-2011 pH at 25 °C 3.5 1.0 pH Units H 01/28/19 1447 DC Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Copper 0.180 0.025 mg1L 02/061l9 1229 02I06119 1229 TAB Lead <0.005 0.005 mglL 02/06/19 1229 02/06/19 1229 TAB Zinc 0.050 0.002 mglL 02/06/19 1229 02/06/19 1229 TAB Definitions Al2: MSIMSD fail recovery, but the LCS passes criteria. H: Analyse was prepared andlor analyzed outside of the analytical method holding time RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated Brittany Smith in the footnote are present and an authorized signature is included. Administration Reported: 02/08/2019 11:24 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 283061910.864.1920 p I www.microbac.com Page 2 of 3 �PMICROBAC Fayetteville Division 2592 Hope Mills Road -- Fayetteville, NC 28306 (910) 864-1920 / *K9A0364- CHAIN OF CUSTODY RECORD ifilifilliffillif CLIENT NAME S ADDRESS: nVent 188 Carolina Road PO A PROSEcr I LOCATtON: Jan '19 Stonnwater Sampling ca J O U- O TYPE OF ANALYSIS L PRESERVATION CODE N N a- U ¢ O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCl G = Sodium Thio CONTACT PERSON: Mark Logue EMAIL: mark.logue(d)nvent.com SAMPLED BY: Mark Lo ue PHONE NUMBER: 910-944-4127 DATE I METHOD OF SHIPMENT: Picked up by Microbac/Ice LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP *C CHL(MINE SULFIDE 01 Storm Water, 01 1/24/18 5:OOAM X 4 B A A C e-Z 02 Storm Water, 02 1 /24/18 5:OOAM X 4 B A A C Lab Relinquished try: Date 11 2S Zo A rn me „ I by: ( re) r/ Date `S%19 e 11: s 3 Frank B ant t 2 eei by: Date 11 A ived Si Daft) DaT, me Refinquishefty: Time Received try: (Sigruhue) Dah 5 s Initials Tumarvund time: REGULAR RUSH',: Comments or SDecial Hazards: �_ d_.`�►�"� IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted January 2, 2019 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 RECEIVED Comments on sample collection or analysis:— Click here to enter text.JAN 0 9 261 9 CENTRAL TILES Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION SAMPLE COLLECTION YEAR_2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []zero -flow [-]water Supply ❑SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks =__> _ - 100 mg/L or 50 mg/L" 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 12/1/18 0.20 14.5 4.9 0.629 <0.005 0.224 <5.00 N/A Outfall #2 12/1/18 0.20 12.8 5.5 2.28 <0.005 0.321 <5.00 N/A Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Manager Titl {print tle) 01/02/2019 (Si 0 a ure} (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 5U Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 OMICROBAC- Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8L0085 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Road Received: 12/05/2018 Aberdeen, NC 28315 Reported: 12/19/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K8L0085-01 Collection Date: 12/01/2018 13:50 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mg1L 12/17/18 1004 TAB 14.5 4.17 mg1L 4.9 1.0 pH Units H 12/06/18 1307 MT 12/10/18 1022 DC Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Copper 0.629 0.025 mg/L 12112/181256 12/12/18 1256 TAB Lead <0.005 0.005 mg/L 12/12/18 1256 12/12/18 1256 TAB Zinc 0.224 0.002 mg/L 12/12/18 1256 12/12/18 1256 TAB Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 Of 3 0MICROBAC!, Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8L0085 Client Sample ID: Storm Water 02, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: KBL0085-02 Collection Date: 12/01/2018 13:50 Wet Chemistry Result RL Units Note Prepared Analyzed Analyst Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) <5.00 5.00 mglL 12/17/18 1004 TAB Method: SM 2540 D-201i Total Suspended Solids 12.8 4.17 mglL 12/06118 1307 MT Method: SM 4500 H+13.2011 pH at 25 `C 5.5 1.0 pH Units H 12/10/18 1022 DC Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals AqueouslEPA 200.7 Rev 4.4 1994 Copper 2.28 0.025 mglL 12/12/18 1259 12112/18 1259 TAB Lead <0.005 0.005 mglL 12/12/18 1259 12/12/18 1259 TAB Zinc 0.321 0,002 mg1L 12/12118 1259 12/12/18 1259 TAB Definitions H: RL: Analyte was prepared and/or analyzed outside of the analytical method holding time Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to�� applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated Brittany Smith in the footnote are present and an authorized signature is included. Administration Reported: 12/19/2018 16:41 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 -K8L0085- Fayetteville Division 2592 Hope Mills Road -- Fayetteville, NC 28306 (910) 864-19201864-8774 fax *MiCROBAC CHAIN OF CUSTODY RECORD PAGE 1 OF 1 CLIENT NAME aADDRESS: nVent 188 Carolina Road Poa PROJECT lIDCATiON: Dec'18 Stormwater Sampling J O U. O TYPE OF ANALYSIS PRESERVATION (CODE) C Z; a O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6'C E = ZN Acetate + <6°C F =HCi G = Sodium Thio CO"TA= PERSON: Mark Logue EMAIL: mark.logue(@nvent.com PIED BY: SAMm Mark Logue PHONE NUMBER: 910-944-4127 DATE IMETHOD OFSHIPMENT: Picked up by Microbac/Ice LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP C CHLORINESULFIDE 01 Storm Water, 01 1211/18 1:50PM X 4 B A A C I I G 2 S 02 Storm Water, 02 12/1118 1:50PM X 4 B A A C I I G Z' Lab Relinquished try: Mark Log r 1 ate �- ime /., • eceireA : (S ) i ate '! 2% �! me I a,-j Rell by: s! Date 2� i 3 :s 7L�r e : (Siylta ) e 4 Date me R lh7gtdsh by: Dat! Time by: (Signature) [Date Time 5 recereed fi InniatS--w Turnaround time: REGULAR RUSWEVIEWED Comments or SDeCial Hazards: -Q�- IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted December 10, 2018__ CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR _2018 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly' November (month) PERSON COLLECTING SAMPLES _Mark Logue DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 [_]zero -flow [:]waterSupply ❑SA Comments on sample collection or analysis:_ Click hereto enter textR EC E 1VE D ❑Other DEC 13 2018 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 CENTRAL. FILES Part A: Stormwater Benchmarks and Monitoring Results DWR SECTI©^r ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 11/24/18 0.15 <4.17 5.0 0.0725 <0.005 0.057 <5.00 N/A Outfall #2 11/24/18 0.15 <4.17 3.9 6.41 <0.005 0.445 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report_ I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Man e \ Title int itl) 12 10 18 (Sign ure (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period ?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches s Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 OMICROBAC'E' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8K0401 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Road Received: 11/27/2018 Aberdeen, NC 28315 Reported: 12/07/2018 Analytical Testing Parameters Cllent Sample ID: Storm Water 01, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K81<0401-01 Collection Date: 11/24/2018 6:30 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mg1L 12/04/18 0945 TAB <4.17 4.17 mglL 11/29/18 1057 MT 5.0 1.0 pH Units H 11/30/18 1220 TAB Metals Result RL Units Note Prepared Analyzed Analyst Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Lead <0.005 0.005 mg/L 12105/18 1422 12/05/18 1422 TAB Zinc 0.057 0.002 mglL 12105/18 1422 12105118 1422 TAB Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst Method: EPA200.7 Copper, Total 0.0725 0.00500 mglL 12/03/18 1314 12/04118 1440 LSJ Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.rnicrobac.com Page 1 of 3 M! C R O B A C' Fayetteville Division 2592 Hope Mills Road Fayetteville, NC 28306 (910) 864-19201864-8774 fax "K8K0401 CHAIN OF CUSTODY RECORD l _ PAGE i OF 1 CLIENT NAME &ADDRESS: nVent 188 Carolina Road Po 7Nov'18 PROJECT I LOCAVON: Stormwater Sampling J O m G TYPE OF ANALYSIS PRESERVATION (CODE) N a V U) H f.. U) CD 0 CODE: A = None B = HNO3 (PH<2) + <6°C C = H2SO4 (pH<2) + <6"C D = NaOH + <6°C E = ZN Acetate + <6°C I= = HCI G = Sodium Thio coNTACTPERsoH: Mark Logue EMAIL: mark. loqu6@nvent.com SAMPLED BY: Mark Logue PHONE NUMBER: 910-944-4127 DATE 1 METHOD OF SHIPMENT: Picked up by Microbacllce LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP -C RES CHLORINE SULFIDE 01 Storm Water, 01 11/24/18 6:30AM X 4 B A A C C-7- 02 Storm Water, 02 11/24/18 6:30AM X 4 B A A C G e Lab Initials Turnaround time: REGULAR RUSH Comments or Soecial Hazards: REVIEWED IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No, NCG030000 Date submitted 11/9118 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 Comments on sample collection or analysis:_ Click hcrc to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2018 SAMPLE PERIOD [] Jan -June ❑ July -Dec or ® Monthly' October 'month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other *0L PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 40 Ile ` =3< ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, s Inches Total Suspended Solids - pH Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organic55 Benchmarks =__> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #11 10/26/18 0.20 28.0 5.1 0.244 <0.0100 0.133 <5.00 N/A Outfall #2 10/26/18 0.20 3.17 4.2 1.68 <0.0100 0.246 <5.00 N/A I + Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquirytif the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Ma6aper T' rin title) 11 9 18 (Si re) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 200 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8J0507 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Road Received: 10126/2018 Aberdeen, NC 28315 Reported: 11/08/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K8J0507-01 Collection Date: 10/26/2018 8:15 Wet Chemistry Method: EPA 1664 Rev. B Oil 8 Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: EPA200.7 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 11/01/18 1003 TAB 28.0 2.50 mg/L 10/29/18 1130 MT 5.1 1.0 pH Units H 10/30/18 1145 TAB Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 0.244 0.00500 mglL 11/01/18 0626 11/05/18 1752 LSJ <0.0100 0.0100 mg1L 11/01/18 0626 11/05/18 1752 LSJ 0.133 0.0200 mg1L 11/01/18 0626 11/05/18 1752 LSJ Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 OMICROBAC'"' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8J0507 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8J0507-02 Collection Date: 10/26/2018 8:15 Wet Gnemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: EPA200.7 Copper, Total Lead, Total Zinc, Total Result RL Units <5.00 5.00 mglL Note Prepared Analyzed Analyst 3.17 2.50 mglL 4.2 1.0 pH Units H 11/01/18 1003 TAB 1G129118 1130 MT 10/30118 1145 TAB Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 1.68 0.00500 mglL <0.0100 0.0100 mglL 0.246 0.0200 mglL Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information an this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. 11101/18 0626 11/05/18 1803 LSJ 11/01/18 0626 11/05/18 1803 LSJ 11/01/18 0626 11/05/18 1803 LSJ Reviewed and Approved By: q--, 21LA�e_ C/UPi�d E� Jeanne Overstreet Client Relationship Specialist, Environmental Reported: 11 /08/2018 12:40 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, INC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 M1CROBAC Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-192018( x K`=Q .1050 7 * CHAIN OF CUSTODY RECORD ltilifilifilifille CLIEW BANE B ADDRESS: nVent 188 Carolina Road ECOWACT PROJECT I LOCATiOw Oct '18 Stormwater Sampling LU O m O TYPE OF ANALYSIS PRESERVATION (CODE) N 0- U n r N O CODE: A = None 6 = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6'C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCI G = Sodium Thio PERSON: Mark Logue ENWL; mark.lo ue nvent.com SAMPLED BY: Mark Logue PHONE NUMBER: 910-944-4127 DATE I METHOD OF SH[PMEW: Picked up by Microbac/Ice LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP IC CHLRORiNE SULFIDE 01 Storm Water, 01 10/26/18 8:15AM X 4 B A A C L 4. 02 Storm Water, 02 10/26/18 8:15AM X 4 B A A C Lab Relinquished by: Date ime Received by: (SWatare) Date Ime Mark Logue � ( v - C 2 by: Date time ei% ) 4atx Tlme Einquilshed fshad by: Date Time Received by: (si�aturc) Date Time 5 fi Initials Turnaround time: REGULAR RUSH Comments or Saecial Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. October 29, 2018 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: RECEIN ED NOV 0 9 Z018 CEN i RAL FIU-S, DWR SECTION Phone:1-910-944-3355 Fax:1-910-944-3418 www.er co.com Please find enclosed the Discharge Monitoring Report (DMR) for September 2018 for the ERICO facility referenced above. If you have any questions, please do not hesitate to call me at (910)-944-4127. Sincer ly Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8977 2363 CADDY® - ER1C0® • ERIFLEX® • ERITECHI - LENTON® VMICROBAC' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K810509 Erico Project Name: Stormwater Samples Mr. Mark Logue Project / PO Number: 0390070 188 Carolina Road Received: 09/28/2018 Aberdeen, NC 28315 Reported: 10/17/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K810509-01 Collection Date: 09/26/2018 17:05 Wet Chemistry _- _ Res uIt RL Units _ Note Prepared _ Analyzed Analyst Method: EPA 1664 Rev. B Oil & Grease (SGT HEM) <5.00 5.00 mg/L 10/03/18 0934 TAB Method: SM 2540 D-2011 Total Suspended Solids 212 2.50 mg/L 10/02/18 0911 MT Method: SM 4500 H+B-2011 pH at 25 °C 6.5 1.0 pH Units H 10/01/18 1506 TAB Analyses Subcontracted to: ECI Metals Result RL Units Note Prepared Analyzed Analyst Method: EPA 200.7 Rev 4.4 1994 Copper 5.85 0.001 mg/L 10/09/18 0000 TD Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared _ Analyzed Analyst Method: EPA200.7 Lead, Total 0.0895 0,0100 mg/L 10/05/18 125B 10/08/18 1830 JYH Zinc, Total 7.19 0.0200 mg/L 10/05/18 1258 10/08/18 1830 JYH Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 0MICROBAC6.1 Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K810509 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K810509-02 Collection Date: 09/26/2018 17:05 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-201i Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 10/03/18 0934 TAB Metals — ---- w _ - --- -- - - Method: EPA 200.7 Rev 4.4 1994 Copper 6.17 2.50 mg1L 10/02/18 0911 MT 4.5 1.0 pH Units H 10/01/18 1506 TAB Analyses Subcontracted to: ED Result _ RL_ - Units _-Note — Prepared___ Analyzed Analyst 0.149 0.001 mg/L 10/09/18 0000 TD Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst Method: EPA200.7 Lead, Total <0.0100 0.0100 mg/L 10/05/18 1258 10108(18 1834 JYH Zinc, Total 0.0320 0.0200 mg/L 10/05/18 1258 10/08118 1834 JYH Definitions H: Analyse was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit RL- Reporting Limit Project Requested Certifications) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to qX applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, Jeanne Overstreet represents only the sample(s) analyzed. This report is incomplete unless all Client Retationship Specialist, Environmental pages indicated in the footnote are present and an authorized signature is Reported: 10/17/2018 11t45 included. Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910,864.1920 p I www.microbac.com Page 2 of 3 J Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-192( �M11CRMCC, CI 'p CHAIN OF CUSTODY RECORD 00�q o b 7 C) - 18�BGWI�Ab CLIENT MAIM SADDRESS' nVent 188 Carolina Road Pop ISept'18 PROJECTILOCATIDIF. Stormwater Sampling J O U C)F TYPE OF ANALYSIS PRESERVATION (CODE) N a : Fes- n y O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6"C E = ZN Acetate + <6°C = HG G = Sodium Thio �01�A�SQ"` Mark Logue EMAIL: mark.loque@nvent.com SAMPLED BY: Mark Logue PHONE NUMBER: 910-944-4127 DATE! METHOD OP SHIPMEMT: Picked up by Microbac/Ice LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEKP'C CHRE NE SULFIDE 01 Storm Water, 01 9/26/18 5:05PM X 4 B A A C 02 Storm Water, 02 9126118 5:05Pm X 4 B A A C Lab Initials Turnaround time: elErqulsA¢d by: ale Reaelved I ate e Mark Logue 1 Z/ �c?.6J 2 /f>' t 3 ReIIn D� /TZ �// R •�SignBhae],.r� aLa ��. 3 (me ished by: Dee irw ecewee by. (Slge wo) ate nne 5 fi REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No, NCG030000 Date submitted 10/31/18 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_e Microbac Fayetteville Lab Cert. # 11 Comments on sample collection or analysis:— Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks =__> - - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 9/26/18 0.20 212 6.5 5.85 0.0895 7.19 <5.00 N/A Outfall #2 9/26/18 0.20 6.17 4.5 0.149 <0.0100 0.0320 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring__ may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant MarlaRer 4Pn 10 31 18 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of'new oil per month. ❑ No discharge this period?2 Outfall No. date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 9/10/2018 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Lo ue LABORATORY_Microbac Fayetteville Lab Cert. # 11 Comments on sample collection or analysis:_ Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' August _ (month) DISCHARGING TO CLASS ❑ORW ❑HQW [:]Trout❑PNA RECEIVED ❑Zero -flow ❑Water Supply [:]SA SEP 24 2018 ❑Other CENTRAL_ FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 DWR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected 1 (mo/dd/yr) 24-hour rainfall amount, Inches' Suspended Solids pH. Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic OrganicsTotal Benchmarks =__> _ - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 8/21/18 0.10 7.83 5.7 0.614 <0.01 0.116 <5.00 N/A Outfall #2 8/21/18 0.10 5.83 5.3 0.342 <0.01 0.0456 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Storm water Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Mana e Title=� -C - 09 10 18 (Signat (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge_" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date: 11/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 OMICROBAC'n' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8H0404 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Dumber: 0388262 REV 002 188 Carolina Road Received: 08/24/2018 Aberdeen, NC 28315 Reported: 09/07/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K8H0404-01 Collection Date: 08/21/201B 11:30 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: EPA200.8 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5,00 mglL 08/29/18 1005 TAB 7.83 2.50 mglL 08/28/18 0932 MT 5.7 1.0 pH Units H 08124118 1530 DC Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 0.614 0.0200 mg1L 08/30/18 0820 08/30/18 1413 JYH <0.00100 0.00100 mg1L 08/30118 0820 08130118 1349 JYH 0.116 0.0250 mglL 08130118 0820 08130/18 1349 JYH Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 �MICROBAC'- Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8H0404 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K81-10404-02 Collection Date: 08/21/2018 11:30 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at25°C Result RL <5.00 5.00 5.83 2.50 Units Note Prepared mglL mglL 5.3 1.0 pH Units H Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Analyzed Analyst 08/29/18 1005 TAB 08/28118 0932 MT 08/24/18 1530 DC Result RL Units Note Prepared Analyzed Analyst Method: EPA200.8 Copper, Total 0.342 0.00200 mglL 08130/18 0820 08130118 1352 JYH Lead, Total <0.00100 0.00100 mglL J 08/30/18 0820 08/30/18 1352 JYH Zinc, Total 0.0456 0.0250 mglL 08/30/18 0820 08/30/18 1352 JYH Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time J: The analyte was positively identified, but the quantitation was below the RL MDL: Minimum Detection Limit RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. Reviewed and Approved By: Jeanne Overstreet Client Relationship Specialist, Environmental Reported: 0910712018 11:43 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NIC 28306 1910.864.1920 p I www.microbac.corn Page 2 of 3 I K8H0404' Fayetteville Division 2592 Hope Miils Road -- Fayetteville, NC 28306 (910) 864-19201864-8774 fax MICROBAC' (`a CHAIN OF CUSTODY RECORD PAGE 1 OF 1 CLIENT NAME I ADDRESS: nVent 188 Carolina Road POd PROJECT I LOCATION: Aug '18 Stormwater Sampling W m LL O TYPE OF ANALYSIS PRESERVATION (CODE) 1V d U F a }_ N O CODE: A = None 8 = HNO3 (pH<2) +<6'C C = H2SO4 (pH<2) + <6°C D = NaOH + <6"C E = ZN Acetate + <6'C F = HCl G = Sodium Thio CONracTPensoN: Mark Logue EMAIL: mark. IooueQnvent ccom SAMPLED BY: Mark Logue PHONE NUMBER: 910-944-41 27 DATE I METHOD OF SHIPMENT: Picked up by Microbacllce LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP 1C cNtatrNe SULFIDE 01 Storm Water, 01 8121118 11:30PM X 4 B A A C Zr 02 Storm Water, 02 8121/18 11:30PM X 4 B A A C Lab Date Z2/ Q Recel.ed att me i - jLog PMa Daft % Ime Rewired by: a") uiI— by: Date Ime Received by: ISW*tae) ate 5 6 Initials Turnaround time: REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _ 08/06/2018 CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR _2018 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly' July (monthf PERSON COLLECTING SAMPLES Mark Logue DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero-flow ❑Water Supply ❑SA LABORATORY Microbac Fayetteville_ Lab Cert. # 11 RECEIVED Comments on sample collection or analysis:! Click here to enter text. ❑Other AUG 2 2 zo,s PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 r Part A: Stormwater Benchmarks and Monitoring Results No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or SO mg/O 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #11 7/21/18 0.75 17.8 5.5 0.268 <0.01 0.094 <5.00 N/A Outfall #2 7/21/18 0.75 3.67 4.3 0.017 <0.01 0.326 <S.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Mana er Title (Pr' t I 08/06/2018 (Sign r (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 5o mg/L* 6.0 -- 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 (VMICROBAC* Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8G0356 Erico Project Name: July 18 Mr. Mark Logue Project 1 PO Number: 0386820 Rev 002 188 Carolina Road Received: 07/24/2018 Aberdeen, NC 28315 Reported: 08/03/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID. K8G0356-01 Collection Date: 07/21/2018 22:20 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+8.2011 pH at 25 °C Metals Method: EPA 200.7 Rev 4.4 1994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 08102118 0933 TAB 17.8 2.50 mglL 07/27118 1503 TAB 5.5 1.0 pH Units Analyses Subcontracted to: ECI Result RL Units 0.268 0.005 mglL <0.01 0.003 mglL 0.094 0.01 mglL H 07/26/18 1114 JR Note Prepared Analyzed Analyst 08/02118 0000 M0 08102118 0000 M0 08/02118 0000 M0 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1 910,864,1920 p j www.microbac.com Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark 7 13 2018 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Out#all No. pate Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 �VMICROBAC` Microbac Laboratories,.Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8F0204 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: 0384896 188 Carolina Road Received: 06/13/2018 Aberdeen, NC 28315 Reported: 06/27/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Stormwater Collected By: Logue Lab Sample ID: K8F0204-01 Collection Date: 06/11/2018 14:10 Wet Chemistry Method: EPA 1664 Rev. B Oil 8 Grease (SGT-HEM) Method: SM 2540 0-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: E200.7 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5,00 mglL 06/14/18 1212 TAB 6.00 2.50 mglL 0611408 0923 MT 5.7 1.0 pH Units H 06115l18 1128 JR Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 0.249 0.0200 mglL 06122/18 0643 0612208 1607 JYH <0.100 0.100 mg1L 06122/18 0643 06122j18 1607 JYH 0.0896 0.0200 mglL 06/22/18 0643 6612208 1607 JYH Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 VMICROBAC'! Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8F0204 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: KBF0204-02 Collection Date: 06/11/2018 14:10 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: E200.7 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mg1L 06/14/18 1212 TAB 5.50 2.50 mg1L 06/14118 0923 MT 4.4 1.0 pH Units H 06/15118 1128 JR Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 9.59 0.0200 mglL 06/22/18 0643 06/22/18 1611 JYH <0.100 0.100 mg1L 06122M8 0643 06122i1B 1611 JYH 0.581 0.0200 mg1L 06122/18 0643 0612208 1611 JYH Definitions H: Analyse was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper ccndition and the reported results conform to applicable accreditation standard unless otherwise noted. 91 ee"ZA�e— 6--'tte.-4d2 e The data and information on this, and other accompanying documents, represents Jeanne Overstreet only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. Client Relationship Specialist, Environmental jeanne.overstreet@microbac.com 06127/2018 1 T43 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 O'`11CROSAC' Fayetteville Division 2592 Hope Mills Road -- Fayetteville, NC 28306 (910) 864-19201864 CHAIN OF CUSTODY RECORD PA =K8F0204* uENTNAMEBADDRESS: nVent 188 Carolina Road POa PRD ECTILOCATION: June '18 Stormwater Sampling tu m LL O TYPE OF ANALYSIS PRESERVATION (CODE) IV CL t j n t— y o CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCI G = Sodium Thio coNsacT PERsoN: Marie Logue EMAIL: mark. lo ue nven .corn SAMPLED BY: Mark Logue PHONE NUMBER: 910-944-4127 DATE I METHOD OF SHIPMENT: Picked up by Microbacllce LAB ID 0 SAMPLE TYPE DATE TIME COMP GRAB PH FLO- TEMP �c CHLORINE SULFIDE 01 Storm Water, 01 6/11/18 2:10PM X 4 B A A C -77 02 Storm Water, 02 6111/18 2:10PM X 4 B A A C pan Reiingulab by: / Date l I Il 6 me �.� Rece gnature) Date y y me r 1 2 R 1 by: Date /3 Time 1 S< Signature) ate lrC/j Erne ' 3 4 i1 Relinquished by: Date Time Received by:ISignsWre) ate 5 6 Initials--b► Turnaround time: REGULAR RUSH Comments or SDeclal Hazards: a IS DATA FOR REG. COMPLIANCE PURPOSE? ND YES WHICH: Page 3 0f 3 f Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. N00030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 Comments on sample collection or analysis:_ Click mere to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' _ May _ (month) R-b SCH'A DING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA JUN 2 5 2018 ❑Zero -flow ❑Water Supply ❑SA CENTRAL FILE ❑Other DVIR SECTIOi.r PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, lnche53 Total Suspended Solids p pH' Standard units Co Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics-5 Benchmarks =__> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 5/17/18 0.25 47.2 5.7 0.539 0.00499 0.177 <5.00 N/A Outfall #2 5/17/18 0.25 12.0 4.6 5.73 0.00505 0.448 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring ,Onay be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Manager _ Ti le nt title) 6/7/18 ( ature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, the must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 VMICROBACro Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8E0321 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: 0383790 REV 002 188 Carolina Road Received: 05/21/2018 Aberdeen, NC 28315 Reported: 06/06/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8E0321-01 Collection Date: 05I1712018 21:00 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B.2011 pH at25°C Method: E200.8 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 05/30/18 1005 TAB 47.2 2.50 mg/L 05122r18 0930 MT 5.7 1,0 pH Units H 05/21/18 1419 JR Analyses Subcontracted to: Microbac Laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 0.539 0.0100 mglL 06104/18 0830 06/04/18 1515 JYH 0.00499 0.00100 mg1L 06M4118 Oa30 06104118 1428 JYH 0.177 0.0250 mg1L 06104/18 0830 06104118 1428 JYH Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 2 OMICROBACI Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K$E0321 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K81=0321-02 Collection Date: 05/17/2018 21:00 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Method: E200.8 Copper, Total Lead, Total Zinc, Total Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 05/30/18 1005 TAB 12.0 2.50 mglL 05/22/18 0930 MT 4.6 1.0 pH Units H 05/21118 1419 JR Analyses Subcontracted to: Microbac laboratories, Inc. - Ohio Valley Result RL Units Note Prepared Analyzed Analyst 5.73 0.100 mglL 06104/18 0830 06/04/18 1522 JYH 0.00505 0.00100 mglL 06/04/18 0830 06/04/18 1431 JYH 0.448 0.125 mg/L 06104118 0830 06/04/18 1519 JYH Definitions H: Analyse was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to "Cyy applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents Jeanne Overstreet only the sample(s) analyzed. This report is incomplete unless all pages indicated Client Relationship Specialist, Environmental in the footnote are present and an authorized signature is included. jeanne.overstreet@microbac.com 0610612018 10:29 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 2 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5/21/18 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY Lab Cert. # Comments on sample collection or analysis:_ Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' April (month) t eDISCHARGING TO CLASS ❑ORW ❑HQW [:]Trout ❑PNA to ��V W ❑Zero -flow ❑Water Supply [:]SA [—]Other �01� PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ® No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 N/A outfall #2 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Mana er Title (P "nt itle t ` &kk-5 21 18 (Signat a (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, 3 Inches Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of recei t of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring_iteport for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY _Microbac Fayetteville Lab Cert. # 11 Comments on sample collection or analysis:_ Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' March rmonth) RECEIV1u15CHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA APR 2 6 Z018 ❑Zero -flow [:]WaterSupply ❑SA ❑Other CENTL<AL FILES DWR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches 3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or 50 mg/L" 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 3/6/18 0.2 27.5 6.1 0.196 <0.003 0.132 <5.00 N/A Outfall #2 3/6/18 0.2 9.50 4.4 3.44 <0.003 0.484 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469,22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Katrina Clark Name (Print name) Plant Manager Ti le (P "nt tit' 04 23 18 ( re) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 OMICROBAC` Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8C0177 Erico Project Name: March 2018 Stormwater Mr. Mark Logue Project 1 PO Number: 0379926 188 Carolina Drive Received: 03/07/2018 Aberdeen, NC 28315 Reported: 04/02/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01. Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8C0177-01 Collection Date: 03/06/2018 14:40 Wet Chemistry Method: EPA 1664 Rev. 13 Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+13-2011 pH at 25 °C Metals Method: EPA 200.7 Rev 4.4 1994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 03116/18 0914 TAB 27.5 2.50 mglL 6.1 1.0 pH Units H Result RL Units Note 0.196 0.005 mg1L <0.003 0.003 mglL 0.132 0.010 mglL 03108/18 0908 MT 03/08/18 1122 JR Prepared Analyzed Analyst 03116118 1247 03/18/18 1247 JAW 03/18/18 1247 03/18/16 1247 JAW 03/16/18 1247 03/18/18 1247 JAW Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 0MICROBAC' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8C0177 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8C0177-02 Collection Date: 03/06/2018 14A0 Wet Chemistry Method: EPA 1664 Rev. B Oil R Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Metals Method: Metals AqueouslEPA 200.7 Rev 4.4 1994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 03/16/18 0914 TAB 9.50 2.50 mg1L 4.4 Result 3.44 <0.003 0.464 1.0 pH Units H RL Units Note 0.005 mglL 0.003 mglL 0.010 mglL Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES 03/08/18 0908 MT 03106/18 1122 JR Prepared Analyzed Analyst 03126/18 1551 03/26118 1551 TAB 03118/18 1251 03/18118 1251 JAW 03118118 1251 03/18/18 1251 JAW Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. \'- � The data and information on this, and other accompanying documents, represents Bonnie K. Sanders only the sample(s) analyzed. This report is incomplete unless all pages indicated Senior Project Manager in the footnote are present and an authorized signature is included. bonniesanders@microbac.com 04102/2018 16:35 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 Ga Fayetteville Division 2592 Hope Mills Road -• Fayetteville, NC 28306 (910) 864-1920 / 8F "'i MICROBAC' CHAIN OF CUSTODY RECORD F ~K8C0177* LIENT NAME a ADDRESS: Pentair 188 Carolina Road POA 0379926 PROJECT l LOCKnON: March '18 Storm Water Monitoring LU 0 M_ 0 11 PE OF ANALYSIS PRESERVATION CODE � a L) H a F O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6"C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCI G = Sodium Thio CONTACT PERSON: Marie Logue EMAIL: maric.logue(ftentair.com SAMPLED BY: Mark Logue PHONE NUMBER: 904-504-3040 DATE / METHOD OF SHIPMENT: 3/7/2018 - Picked up by Microbac LAB ID # SAMPLE TYPE DATE TIME COMP GRA9 PH FLOW TEMP'C CHLORINE SULFlDE 01 Storm Water, 01 316118 2:40PM X 1 A A' C l 02 Storm Water, 02 316118 2:40PM X 8 A A Z F Lab Re shed : '7// me Rece by: (Slgnatute► Date Time Re 'ad by: #3t Timed R4K d ty: (S19naten) Date e 11nQuIshed by: me Received by:(Signature) Date Ime 6 Initials—io. Turnaround time: REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3� NC Division of Energy, Mineral and Land Resources NPDES Stormwater Permit Contacts Summary \C DEMI,R has the followin? contact information in our Permil Database for your nermil as of4/23/2018. Permit Number: NCG030627 Permit Type: Metal Fabrication Stormwater Discharge COC Facility Name: ERICO International Corporation Facility Addressl: 188 Carolina Rd Facility Address2: City, State & Zip: Aberdeen. NC 28315 -_ MUST submit a Chan a of Name/Ownership form to DEMLR to make any changes to this Owner information. 7_ 9 (Click Here for �C'hanae of Name/Ownership"Form) Owner Name: Erioo International Corporation Owner Type: Non -Government Owner Type Group: Oroanization *** Legally Responsible for Permit *** (Responsible corporate o(ficer/prindple executive officer or ranking elected official/general partner or proprietor, or any other person with delegated signatory authority from the legally responsible person.) Owner Affiliation: Garret Agee Title: Addressl: 188_Car4line Rd Address2: City, State & Zip: Aberdeen, NC 28315 Work Phone: 910-944-4100 Fax: Email Address: garret.agn0pentair-W { *** Permit Annual Fee Billing *** Billing Month: August Owner Contact Person(s)n- Contact Name Ii11@ Address Phone Fpxx Email Facility Contact Person(s) - Contact Name IILC Address Phone fax Emdu Garret Agee 188 Caroline Rd, Aberdeen, NC 28315 910-9M-4100 garret.agee@pentair .Corn Permit Contact Person(s) Contact Name Lit: Address Phone f lu Emai1 Permit Billing Contact 7-7 Contact Name IJft Address phone F" i MAU Mark Logue 188 Carolina Rd, Aberdeen, NC 28315 910-944-4127 910-944-2871 mark.logue@pentair .Com 4/23/2018 Page I Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 3/14/18 CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR _2018 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly' _^ February_ (month) PERSON COLLECTING SAMPLES Mark Logue DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY_Microbac Fayetteville_ Lab Cert. # 11 RECEIVED ❑Zero -flow ❑Water Supply ❑SA Comments on sample collection or analysis:_ Click here to enter text. [:]Other LIAR 19 2018 CENTRAL FILESPLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 Part A: 5tormwater Benchmarks and Monitoring Results OWR SECTION ❑ No discharge this period:2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2/25/18 0.1 71.8 5.7 0.607 <0.003 0.211 <5.00 N/A Outfall #2 2/25/18 0.1 68 5.6 0.425 <0.003 0.076 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Peter Hannis Name (Print name) Plant Ma er Title (Pr nt e / 3 13 18 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 �VMICROBAC` Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8B0927 Erica Project Name: Stormwater Samples Mr. Mark Logue Project/ PO Number: 0379441 188 Carolina Drive Received: 02/27/2018 Aberdeen, NC 28315 Reported: 03/12/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8130927-01 Collection Date: 02/25/2018 14:30 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Metals Method: EPA 200.7 Rev 4.4 1994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mg/L 03106118 0905 TAB 71.8 2.50 mglL 5.7 1.0 pH Units Result RL Units 0.607 0.005 mg1L <0.003 0.003 mg/L 0.211 0.010 mg/L 03/01118 0921 MT H 03/05/18 1458 TAB Note Prepared Analyzed Analyst 03/01/18 2131 03/01/18 2131 JAW 03/01/18 2131 03/01/18 2131 JAW 03/01/18 2131 03/01/18 2131 JAW Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1 910.864.1920 p I www.microbac.com Page 1 Of 3 *MICROBAC"' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8BO927 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Lague Lab Sample ID: 1<8B0927-02 Collection Date: 02/25/2018 14:30 Wet Chemistry Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) Method: SM 2540 D-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Metals Method: EPA 200.7 Rev 4.4 1994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Analyst <5.00 5.00 mglL 03/06/18 0905 TAB 68.0 2.50 mglL 03101/18 0921 MT 5.6 1.0 pH Units H 0310511B 1458 TAB Result RL Units Note Prepared Analyzed Analyst 0.425 0.005 mg1L 03/01/18 2134 03/01/18 2134 JAW <0.003 0.003 mglL 03/01/18 2134 03/01/18 2134 JAW 0.076 0.010 mglL 03/01/18 2134 03101118 2134 JAW Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. \�I The data and information on this and other accompanying documents, represents Bonnie K. Sanders only the sample(s) analyzed. This report is incomplete unless all pages indicated Senior Project Manager in the footnote are present and an authorized signature is included. bonnie sanders@m icrobac.com 03112/2018 20:53 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 -�VMIcRoBAc- Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-19201 P" CHAIN OF CUSTODY RECORD CLIENT NAME& ADDRESS: Pentair 188 Carolina Road PO# 0379441 iFeb'18 PROJECT I LOCATION- Storm Water Monitoring W F m ttr O TYPE OF ANALYSIS PRESERVATION (CODE) c N ii U 3: U) ,p CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6*C E = ZN Acetate + <6°C F = HCI G = Sodium Thio CONTACT PERSON: Mark Lague EMAIL: mark.lopue(ftentair.com SAMPLED BY: Mark Logue PHONE NUMBER: 904-504-3040 DATE! METHOD OF SHIPMENT: 2/27/2018 LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH PHSULFIDE FLOW TEMP.0 CH 01 Storm Water, 01 2/25118 2:30PM X 1 B A A C Z �� 02 Storm Water, 02 2/25/18 2:30PM X 1 B A A C C Z 1 ! la r Lab Relin ed by: Date Time Received 4y: (Signature) Date me RNi fished by: 3 Date Z �-37 Time Recery mre) 4 Dah a a7, I ilme I7 R nquished by: Date Time Received try: (Signawre) Date 5 fi Initials_ Tumaround time: REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 3/2/18 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue SifiAR 0 2��3 LABORATORY—Microbac Fayetteville Lab Cert. # 11 e Comments on sample collection or analysis:— Click here to Dy'r � ate. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' January month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period? Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 1/29/18 0.5 1.33 5.8 0.206 <0.003 0.045 <5.00 N/A Outfall #2 1/29/18 0.5 6.33 4.9 1.62 <0.003 0.119 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Mark Lo ue Name (Print name) EHS Manager Title (Print title) 3218 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 OMICROBAC Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8Ao793 Erico Project Name: Stormwater Samples Mr. Mark Logue Project 1 PO Number: NIA 188 Carolina Drive Received: 01/29/2018 Aberdeen, NG 28315 Reported: 02/06/2018 Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8A0793-01 Collection Date: 01/28/2018 7:00 Wet Chemistry Result RL Units Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) <5.00 5.00 mg1L Method: SM 2540 D-2011 Total Suspended Solids 1.33 1.00 mg1L Method: SM 4500 H+B-2011 pH at 25 °C 5.8 0.1 pH Units Metals Result RL Units Method: Metals Aqueous/EPA 200.7 Rev 4.4 1994 Copper 0.206 0.005 mg/L Lead <0.003 0.003 mg1L Zinc 0.045 0.010 mg/L Note Prepared Analyzed Lab 0113011 B 0930 FAY H 01/31/18 0905 FAY 01/31/16 1208 FAY Note Prepared Analyzed Lab 02/05118 1741 02305118 1741 FAY 02105/18 1741 02105118 1741 FAY 02/05/18 1741 02105118 1741 FAY Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 OMICROBAC- Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K8A0793 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K8A0793-02 Collection Date: 01/28/2018 7:00 Wet Chemistry Result RL Units Note Prepared Analyzed Lab Method: EPA 1664 Rev. B. Oil & Grease (SGT-HEM) <5.00 5.00 mg/L 01130i18 0930 FAY Method: SM 2540 D-2011 Total Suspended Solids 6.33 1.00 mg/L 01131i18 0905 FAY Method: SM 4500 H+B-2011 pH at 25 °C 4.9 0.1 pH Units H 01/31118 1208 FAY Metals Result RL Units Note Prepared Analyzed Lab Method: Metals AqueouslEPA 200.7 Rev 4.4 1994 Copper 1.62 0.005 mg/L 02/05118 1746 02/05/18 1745 FAY Lead <0.003 0.003 mg/L 02tOS118 1745 02/0508 1745 FAY Zinc 0.119 0,010 mg/L 02105118 1745 02/0508 1745 FAY Laboratory FAY: Microbac Laboratories, Inc. - Fayetteville Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Reviewed and Approved By: Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted The data and information on this, and other accompanying documents, represents Bonnie K. Sanders d4L/i 4 J only the sample(s) analyzed. This report is incomplete unless all pages indicated Senior Project Manager in the footnote are present and an authorized signature is included. bonnie.sanders@microbac.com 02/0612018 23:10 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 (5)MICRQ$,4C' Fayetteville Division 2592 Hope Mills Road -- Fayetteville, NC 28306 (910) 864-1920 CHAIN OF CUSTODY RECORD �iuiui�mii� CLIENT NAME a ADDRESS: Pentair 188 Carolina Road PON PROJECT I LOCATION: Jan '18 Storm Water Monitoring ui J O � O TYPE OF ANALYSIS PRESERVATION (CODE) c N a V to C f— N O CODE: A = None B = HNO3 (pH<2) + <6'C C = H2SO4 (pH<2) + C6°C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCI G = Sodium Thio CONTACT PERsoN: Mark Logue EMAIL: mark.logue@Dentair.com SAMPLED BY: i.. _, k Logue PHONE NUMBER: 904-504-3040 DATE f METHOD OF SHIPMENT: 112912018 LAS ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP'C CHLORINE ORINE SULFIDE 01 Storm Water, 01 1128/17 7:OOAM X 1 B A A �C C}� 02 Storm Water, 02 1128117 7:OOAM X 1 B A A a C Z 1 Lab Irtttlals--j� Date me ezd Ned try: (S"tareJ Date Time ®Rellistind by:a �. E Ime (3 Z, eca by: ( Ipnature) Date 7lme 3 i"�d by: pate fine Received IgnetureJ Data me 5 B Turnaround time: REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. January 10, 2018 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: Phone: 1-910-944-3355 Fax: 1-910-944-3418 www.erico.com �� AR SECS10SS41yG UW ltnRf~4101 PROC . Please find enclosed the Discharge Monitoring Report (DMR) for December 2017 for the ERICO facility referenced above. If you have any questions, please don't hesitate to call me at (910)-944-4127. Sincerely, Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8977 2424 CADDY® • ERICO® • ERIFLEX® • ERITECH® - LENTON® Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 1 10 18 CERTIFICATE OF COVERAGE No. NC.G030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY_e Microbac Fayetteville Lab Cert. # 11 Comments on sample collection or analysis:— Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 12/8/17 1.00 <1.00 5.0 0.121 <0.003 0.055 <5.00 N/A Outfall #2 12/8/17 1.00 <1.00 5.0 0.648 <0.003 0.129 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Peter Hannis Name (Print name) Interim Plant Manager Title ( iiL title) 1/10/18 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfall No. Date sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L' 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B ' See.General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring period in the case of "No Discharge" reportsl to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 &)MICROBAC`' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K7L0390 Erico Project Name: Stormwater Samples Mr. Mark Logue Project ! PO Number: 0375515 REV 002 188 Carolina Drive Received: 12/11/2017 Aberdeen, NC 28315 Reported: 01/02/2018 Case Narrative Repot amended on January 2, 2018 for work order K71.0390 that was originally reported on Decernber 29, 2017 to add oertiflcatlon. Analytical Testing Parameters Client Sample ID: Storm Water 01, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K71-0390-01 Collection Date: 12/08/2017 10:30 Wet Chemistry Method: EPA 1664 Rev. B Oil 8r Grease (SGT-HEM) Method: SM 2540 0-2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Metals Method: EPA 200.7 Rev 4.41994 Copper Lead Zinc Result RL Units Note Prepared Analyzed Lab <5.00 5.00 mgfL 12/14/17 0952 FAY <1.00 1.00 mg/L 12111117 1445 FAY 5.0 0A pH Units H 12J12117 1433 FAY Result RL Units Note Prepared Analyzed Lab 0.121 0.005 mg/L 12118/17 1902 12J18/17 1902 FAY <0.003 0.003 mg/L 121181171902 12JI81171902 FAY 0.055 0.010 mg/L 12118/17 1902 12118/17 1902 FAY Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 OMICROBAC"' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K7L0390 Client Sample ID: Storm Water 02, Grab Sample Matrix: Aqueous Collected By: Logue Lab Sample ID: K71-0390-02 Collection Date: 12/0812017 10:30 Wet Chemistry Method: EPA 16" Rev. 8 Oil & Grease (SGT-HEM) Method: SM 2540 D 2011 Total Suspended Solids Method: SM 4500 H+B-2011 pH at 25 °C Result RL Units Note Prepared Analyzed Lab <5.00 5.00 mglL 12114/17 0952 FAY <1.00 1.00 mg/L 121111171445 FAY 5.0 0.1 pH Units H 12/12/17 1433 FAY Metals Result RL Units Note Prepared Analyzed Lab Method: EPA 200.7 Rev 4.41994 Copper 0.648 0.005 mglL 12118/17 1925 12/181171925 FAY Lead <0.003 0.003 mglL 12/18/17 1925 12f181171925 FAY Zinc 0.129 0.010 mglL 12/18/17 1925 12/18/17 1925 FAY Laboratory FAY: Microbac Laboratories, Inc. - Fayetteville Definitions H: Anslyte was prepared and/or analyzed outside of the analytical method holding time RL: Reporting Limit Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. Reviewed and Approved By: Jeanne Overstreet Project Manager isanne.averstnmt@microbac.com 01/0212018 15:20 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 2 of 3 (5)MICROBACY Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-1920 / F *K7L0390* CHAIN OF CUSTODY RECORD 110111111111111 CLRNrNAME SADDRESS. Pentair 188 Carolina Road Poe PROJECT I LOCATION: Dec'17 Storm Water Monitoring LU O LL O TYPE OF ANALYSIS PRESERVATION (CODE) ii U .� a (0 CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH4) + <6°C D = NsOH + <6"C E = ZN Acetate + <6°C F - HCI G = Sodium Thlo Co'n"M PERSON: Mark Logue EMAIL: mark.logue(@Pentair.com SAMPLED 8Y: Mark Logue PHONE NUMBER 904-504-3040 DATE l METHOD OF SHIPMENT: 12/11 /17 Sample Pick Up LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP •C CHWRtKE SULRDE 01 Storm Water, 01 1218117 10.30AM X 1 B A A C �� JY.� 02 Storm Water, 02 1218/17 10:30AM X 1 A B A A At C Lab lnitials--O� epnquhbeC by: Date TIM 7(1A eee Cy:(Si ) ah rmw Date Twne R by: i 9 Ie2-ll -�7 j : 00 41 1 J. Ilnqukshed oy ate Time by: Sigramre) ate Time '51 e Turnaround time: REGULAR Comments or Special Hazards: RUSH IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _ _11/28/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Mark Logue LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2017 _ SAMPLE PERIOD ❑ Jan -June ❑ July -Dec RECEIVED or ® Monthly' October (month) DISCHARGING TO CLASS ❑ORW ❑HQW [:]Trout ❑PNA DEC 0 2Uii ❑Zero -flow [:]WaterSupply ❑SA CENTRAL FILES ❑Other GVVR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 10/10/17 1.00 72.7 6.4 0.371 0.006 0.141 <5.00 N/A Outfall #2 10/10/17 1.00 195 5.2 5.98 0.024 0.457 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Garret Agee Name (Print name) Plant Manager Title (Print title) 11/28/17 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Rate Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab _results _(or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SW U-245, last revised 10/25/2012 Page 3 of 3 OMICROBAC- Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 10/27/17 Mr. Mark Logue Project: Stormwater Samples Date Received: 10/11/17 188 Carolina Drive Date Sampled: 10/10/17 Aberdeen NC, 28315 Sampled By: Logue Storm Water 01, Grab K7J04 l 2-01 Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 0.371 mg/L 10/17/17 11:43 JAW EPA 200.7 Rev 4A 1994 Lead 0.006 mg/L 10/17/17 11:43 JAW EPA 200.7 Rev 4A 1994 Oil & Grease (SGT-HEM) <5.00 mg/L 10/17/17 09:00 JR EPA 1664 pH 6.4 pH Units 10/12/17 16:56 JR SM 4500 H-+-B-2000 H (Aqueous) Total Suspended Solids 72.7 mg/L 10/13/17 10:10 TAB SM 2540 D-1997 Zinc 0.141 mg/L 10/17/17 11:43 JAW EPA 200.7 Rev 4A 1994 Storm Water 02, Grab K7J04 12-02 Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc, - Fayetteville Copper 5.98 mg/L 10/27/17 11:33 JAW EPA 200.7 Rev 4.4 1994 Lead 0.024 mg/L 10/17/17 11:43 JAW EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-HEM) <5.00 mg/L 10/17/17 09:00 JR EPA 1664 pH 5.2 pH Units 10/12/17 16:56 JR SM 4500 H+_B-2000 H (Aqueous) Total Suspended Solids 195 mg/L 10/13/17 10:10 TAB SM 2540 D-1997 Zinc 0.457 mg/L 10/17/17 1 1 :43 JAW EPA 200.7 Rev 4.4 1994 QC Batch Run - (Microbac tabmalaries. Inc. - Fayyetleville) Analyte Result Units Source RPD Limit Total Suspended Solids 28.0 mg/L K7J0404 7 5 Copper 0.314 mg/L K7J0451 0.3 10 Copper 0.089 mg/L K7J0451 136 10 Total Suspended Solids 49.5 mg/L K7J0385 2 5 Total Suspended Solids 45.4 mg/L K7J0332 3 5 Zinc 1.29 mg/L K7J0451 0.01 10 Copper 0.005 mg/L K7J0580 93 10 Lead 0.010 mg/L K7J0451 132 200 Microbac Laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f I www.microbac.com &)MICROBAC- Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 10/27/17 Mr. Mark Logue Project: StormwaterSamples Date Received: 10/11/17 188 Carolina Drive Date Sampled: 10/10/17 Aberdeen NC, 28315 Sampled By: Logue QC Batch Run - (Microbac Laboratories, Inc. - Fayelleville) Analyte Result Units Source RPD Limit Zinc 1.38 mg/L K7J0451 25 10 Lead 0.233 mg/L K7J0451 0.9 200 Copper 0.243 mg/L K7J0580 4 10 Notes and Definitions H Analyte was prepared and/or analyzed outside of the analytical method holding time State Certifications: Respectfully Submitted NCDNR #11 NCDOH #37714 Bonnic K. Sanders, Senior Project Manager Thank you for your business. We invue purr feedbac7 on our level ofsemice to rom Please conracl the Division Manager. Rob Dermer or 910-864-1926 wish am guesrinns. YW4 mar also e('nrac•r J. Trevor Bnvice. President ar prrcidcnt amicrvrhac.enm Microbac Laboratories, Inc. Page 2 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f I www.microbac.com C IwilCRaBAC• Fayetteville Division 2592 Hope Mills Road - Fayetteville, NC 28306 (910) 864-1920 / CHAIN OF CUSTODY RECORD *K7J0412* 11111111111M11111 CuENT NAME a ADDRESS: Pentair 188 Carolina Road PoO PROMCTrLOCATION: Oct'17 Storm Water Monitoring LU r- m U. O TYPE OF ANALYSIS PRESERVATION (CODE) c (L V Fes— n •N O CODE: A = None B = HNO3 (pH<2) + <6"C C = N2SO4 (pH<2) + <6°C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCl G = Sodium Thio 0°'7T4�pE` ONi Mark Logue EMAd mark.lo ue entair.com SAMPLED BY: Mark Logue PHONE NUMBER. 904-504-3040 DATE I METHOD OF SHIPMENT: C n, 10/11 /07 -Dropped off at lab. 3. i T LAB ID ii SAMPLE TYPE DATE TIME COMP &RAB r PH FLOW TeMp CHtARWE suLFmE 01 Storm Water, 01 10/10/17 4:10 m X 1 B A A C LZ- e 02 Storm Water, 02 10/10it /17 4:10pm X 1 B A A -01 C LZ 2' :S o Lab _ hy: Gatffe me Recelvad 6y: lure) Daft me Z. f by: E Date me Rece 17y: (5lptlature) Date Tww 3 4 quishedby: Date Time Received Oy: (Sl�uh�rej ate .5 6 re Initials--j. Tumaround time: REGULAR F:a,RHSH:n Comments or Special Hazards: i V- jf�� lT " t IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of ERICO International Corporation Phone: 1-910-944-3355 188 Carolina Road Fax: 1-910-944-3418 Aberdeen, NC 28315 www.erico.com U.S.A. September 21, 2017 Division of Water Quality RECEIVED Attn: DWQ Central Files OCT 0 3 2017 1617 Mail Service Center CENTRAL Raleigh, North Carolina 27699-1617 t"WR SECTsup4 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: Please find enclosed the Discharge Monitoring Report (DMR) for August 2017 for the ERICO facility referenced above. Note that the pH for Site #2 is extremely low at 1.6. The laboratory report was received eighteen days after the sample was taken. Retesting of the sample confirms a low pH. It is believed that, during sampling, there was contamination from one of the acid preservatives in either the oil/grease sample container (sulfuric acid) or metals sample container (nitric acid). There is no indication of spill or release from the facility that could contribute to a low result. Further, stormwater samples obtained on September 11, 2017 indicate a normal pH of 6.2 in the outfall from Site #2. If you have any questions, please don't hesitate to call me at (910)-944-4127. Sincerely, I el'A Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 2977 2288 CADDY® • ERICO® . ERIFLEX® . ERITECN® • LENTON® Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted __9/21/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583___ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' August 'month) DISCHARGING TO CLASS ❑ORW ❑HCJW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?z Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, a Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 8/24/17 1.25 45.8 5.3 0.235 <0.003 0.0991 <5.00 N/A Outfall #2 8/24/17 1.25 179 3.21 0.0110 0.334 <5.00 N/A F- 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 M Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Note: Results must be reported in nui format. When results are below the a limit, reporting limit, etc. in mg/L. Garret Azee Name (Print name) Title ( (Signature) 9 z///-7 (Date) rical t. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical icable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection Note: if you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period: C}utfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AAND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Dischar e" re arts, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharae" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Pentair Erico Intl. Corp. Mr. Mark Logue 188 Carolina Drive Aberdeen NC, 28315 OMICROBAC- Fayetteville Division Certificate of Analysis Project: Stormwater Samples Storm Water 01, Grab K 7H 1 l 82-0 l Dale Reported: 09/11/17 Date Received: 08/25/17 Date Sampled: 08/24/17 Sampled By: Logue Analyte Result Units Analyzed Analyzed By Method Qualifier J Analyzed by: Microbac Laboratories, Inc. - Fayetteville Oil & Grease (SGT-HEM) <5.00 mg/L 09/01/17 08:22 JR EPA 1664 PH 5.3 pH Units 08/29/17 10:13 ELM SM 4500 H+B-2000 H (Aqueous) Total Suspended Solids 45.8 mg/L 08/30/17 10:24 JR SM 2540 D-1997 Analyzed by: Microbac Laboratories, Inc. - Ohio Valley Copper, Total 0.235 mg/L 09/01/17 17:37 KDD E200.7 Lead, Total <0.00500 mg/l. 09/01/17 17:37 KDD E200.7 Zinc, Total 0.0991 mg/L 09/01/17 17:37 KDD E200.7 Storm Water 02, Grab K7H l 182-02 Analyte Result Units Analyzed Analyzed By Method _ Qualifier Analyzed by: Kcrobac Laboratories, Inc. - Fayetteville Oil & Grease (SGT-I-IEM) <5.00 mg/L 09/01/17 08:22 JR EPA 1664 pH 1.6 pH Units 08/29/17 10:13 ELM SM 4500 H+13-2000 H (Aqueous) Total Suspended Solids 179 mg/L 08/30/17 10:24 JR SM 2540 D-1997 Analyzed by: Microbac Laboratories, Inc. • Ohio Valley Copper, Total 3.21 mg/L 09/01/17 17:48 KDD i 200,7 Lead, Total 0.0110 mg/1- 09/01/17 17:48 KDD E200.7 Zinc, Total 0.334 mg/L 09/01/17 17:48 KDD E200.7 QC Batch Run - (A icroharLaborarories. Inc. - Fayetterdlle) Analyte Result Units Source RPD Limit Total Suspended Solids 550 mg/L K7H 1230 16 5 Total Suspended Solids 854 mg/L K7H 1230 6 5 Total Suspended Solids 178 mg/L K7H l l 79 36 5 PH 1.6 pH Units K71.11182 0 200 QC Batch Run - (Aficrahar laboratories, Inc'. - Ohio ; wley) Analyte Result Units Source RPD Limit Microbac Laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p E 910.864.8774 If I www.microbac.com PfiICRO BAC` Fayetteville Division 2592 Hope Mills Road - Fayetteville, NC 28306 (910) 864-1920 ! CHAIN OF CUSTODY RECORD -K7H1182' CLIENT NAME&ADDRESS: Pentair 188 Carolina Road PON 0370261 PROJECT I LOCATION: Aug '17 Storm Water Monitoring J AM LJ- , O TYPE OF ANALYSIS PRESERVATION (CODE) N IL o �- N Q O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + -e60C D = NaOH +<6'C E = ZN Acetate + <6°C F = HCl G = Sodium Thio CONTACT PFASON: Mark Logue EMAIL: mark- logue(a)pentair_com SAMPLED BY: Mark Logue PHONE NLIM8ER: 904-504-3040 DATE 1 METHOD OF SHIPMENT: 8125/17 - Lab pickup LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH Flow TEMP'C RES. cHLORME SULFIDE 01 Storm Water, 01 8124/17 4:30pm X 1 B A A '!o 02 Storm Water, 02 8/24/17 4:30 m X 1 B A A C�� Lab Innials—p- Rehoquia ed by: Gate T11T10 Rec by: tern} Data TIme r 710oks by: 3 I'RrUnquishttWby: Date $fps ( Time Rec azure, Data a l-7 Time t.c545 Date Time Received by: (Signature) ate Time 5 6 Turnaround time: REGULAR Comments or Special Hazards: RUSH `9 tyl IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. September 21, 2017 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: Phone:1-910-944-3355 Fax:1-910-944-3418 www.erico.com RECEIVED OCT 0 3 2017 CENTRAL FILES DWR SECTION Please find enclosed the Discharge Monitoring Report (DMR) for September 2017 for the ERICO facility referenced above. If you have any questions, please don't hesitate to call me at (910)-944-4127. Sincerely, Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8976 9158 CADDY® • ERICO' - ERIFLEX® - ERITECN® • LENTON' Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 9/21/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Lowe LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed bX Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly) September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches"i Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 9/11/17 0.10 15.3 6.0 0.270 0.00159 0.160 <5.00 N/A Outfall #2 9/11/17 0.10 3.58 6.2 0.0956 <0.0005 0.0240 <5.00 N/A 1 Monthly sampling`(instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Garret Agee Name (Print name) Plant Manager Title (Prin - e) � ZI ( ignature) (Dat ) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. - Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period: Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =_-> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab_ results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 0MICROBACA, Fayetteville Division Certificate of Analysis Pentair Erico lnll. Corp. Dale Reported: 09/21/17 Mr. Mark Logue Project: Slormwater Samples Date Received: 09/11/17 188 Carolina Drive Date Sampled: 09/11/17 Aberdeen NC, 28315 Sampled By: Logue Storm Water Site #l, Grab K7I0280-01 I Analyte Result Units Analyzed Analyzed By Method Qualifier j Analyzed by: Mlcrobac Laboratories, Inc. - Fayetteville Oil & Grease (SGT-HEM) <5.00 mglL 09/14/17 09:50 JR EPA 1664 pH 6.0 pH Units 09/15/17 11:05 ELM SM 4500 H+B-2000 H Total Suspended Solids 15.3 Analyzed by: Microbac Laboratories, Inc. - Ohio Valley Lead, Total 0.00159 Zinc, Total 0.160 Copper, Total 0.270 (Aqueous) mg/L 09/13/17 10:15 TAB SM 2540 D-1997 11 09/15/17 14:59 JYH L200.8 mg/L 09/15/17 14:59 JYH E200.8 mg/L 09/15/17 15:31 JYl-1 E200.9 Storm Water Site #2, Grab K710280-02 I Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Oil & Grease (SGT-HEM) <5.00 mglL 09/14/17 09:50 JR EPA 1664 pH 6.2 pH Units 09/15/17 1 1:05 ELM SM 4500 H+B-2000 H Total Suspended Solids 3.58 Analyzed by: Microbac Laboratories, Inc. - Ohio Valley Copper, Total 0.0956 Lead, Total <0.000500 Zinc, Total 0.0240 (Aqueous) mg/L 09/13/17 10:15 TAB SM 2540 D-1997 mg/L 09/15/17 15:02 JYH E200.8 mg/L 09/I5/17 15:02 JYH E200.8 mglL 09/15/17 15:02 JYH E200.8 J QC Batch Run - (Microbac Laborataries. Inc. - Fayetteville) I Analyte _ Result Units Source RPD Limit pH 6.7 pH Units K710474 1 200 Total Suspended Solids 171 mg/L K710242 2 5 Total Suspended Solids 167 mg/L K710306 2 5 QC Batch Run - (Micrabae Laboratories, Inc. - Ohio ;Wley) Analyte Result Units Source RPD Limit Microbac Laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f I www.microbac.com of in; R 0 B � "- Fayetteville Division 2592 Hope Mills Road -- Fayetteville, NC 28306 (910) 864-1 CHAIN OF CUSTODY RECORD *K710280* CLIENT NAME S ADDRESS: Pentair 188 Carolina Drive Aberdeen, NC 28315 PON ILA-'[( '--A PROJECT r LOCATION: iStormwater #OF B O T T L E s TYPE OF ANALYSIS PRESERVATION CODE N U a C7 CODE: A= None B = HNO3 (pH<2) + <4'C C = H2SO4 (pH<2) + <4•0 D = NaOH + <4'C E= ZN Acetate + <4'C F=HC1 CONTACT PERSOOW , rNC� lam- �9 PHONE: Cry C (J l / ( 1 f 4 SAMPLER: N , f t�" �- DATEH DOFS MEN ) fG :Microbac LAB ID # SAMPLE TYPE DATE TIME COUP GRAB pH FLD D.O. TEMiP'C cFIRES. r Storm Water, Site 1 //�� Z X 1 B Z- 1 A 1 A 2 C �Z z Storm Water, Site 2 � C .� X L Z 1 1 A 2 C L� RslinquisR Date Tin* Recovsd try: (Signatu / Date Time - 2 R �n sh t>r Date f « TimeC Q �J�U Raeai ad atura) Cah/� ^� Time 3 i 4 Relinquished . Data urn Ra ived tqr. (Signarum) Date Time S 6 Comments or Special Hazards: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 8/1/2017 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore �T PERSON COLLECTING SAMPLES _Mark Logue LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec _ or ® Monthly' July (month) C)EI )SSHARGING TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA Kr _ ❑Zero -flow ❑Water Supply [:]SA N,� 2 ❑other D� �C�ES C)N PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Tvtal Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 7/19/17 0.75 121 6.9 1.26 0.008 0.429 10.1 N/A Outfall #2 7/19/17 0.75 149 5.3 5.99 <0.003 0.509 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in.40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Garret Agee Name (Print name) Title �ipe) 8/17/17 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 -- 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART If SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports/ to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." {Signature of Permittee} (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 &)MICROBAC'" Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 07/27/17 Mr. Mark Logue Project: Stormwater Samples Date Received: 07/19/17 188 Carolina Drive Date Sampled: 07/19/17 Aberdeen NC, 28315 Sampled By: Cogue Slurrn Water 01, Grab K7G0523-01 Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 1.26 mg/L 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 Lead 0.008. mg/L 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-HEM) 10,1 mg/L 07/26/17 09:00 JR EPA 1664 pH 6.9 pH Units 07/24/17 12:06 ELM SM 4500 H+B-2000 11 (Aqueous) Total Suspended Solids 121 mg/1- 07/21/17 10:08 TAB SM 2540 D-1997 Zinc 0.429 mg/L 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 Storm Water 02, Grab K7G0523-02 Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 5.99 mg/h 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 Lead <0.003 mg/L 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGI'-l1LM) <5.00 mg/L 07/26/17 09:00 JR EPA 1664 pH 5.3 pH Units 07/24/17 12:06 ELM SM 4500 H+B-2000 H (Aqueous) Total Suspended Solids 149 rng/L 07/21/17 10:08 TAB SM 2540 D-1997 Zinc 0.509 mg/1- 07/27/17 10:02 AC EPA 200.7 Rev 4.4 1994 QC Batch Run - (Mrcrahae Laboratories, Inc. - Fayetteville) Analyte Result Units Source RPD Limit Copper ND mg/L K7G0692 5 10 Copper 0.260 mg/L 0059510 0.2 200 pH 5.3 pH Units K7G0523 0 200 Total Suspended Solids 156 mg/L K7G0524 4 5 Total Suspended Solids 35.0 mg/L K7G0483 14 5 Copper 637 mg/L K7150523 0.3 10 Zinc 0.515 mg/L K7G0523 1 10 Lead ND mg/L K7G0523 200 Microbac Laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f ( www.microbac.com .7i OMICROBAC Fayetteville Division Certificate of Analysis Pentair Erico Intl, Corp. Date Reported: 07/27/17 Mr. Mark Logue Project: Stormrrater Samples Date Received: 07/19/17 188 Carolina Drive Date Sampled: 07/19/17 Aberdeen NC, 28315 Sampled By: Logue QC Batch Run - (Microhac Laboratories, lne. - Fayelteville) Analytc Result Units Source RPD Limit Copper 6.20 mg/L K7G0523 3 10 Total Suspended Solids 163 mg/L K7G0523 9 5 Lead 0.237 mg/L K7G0692 l 200 Zinc 0.596 mglL K7G0692 0.3 10 Zinc 0.768 mg/L K7G0523 0.2 10 Zinc 0.330 mg/L K7G0692 2 10 Lead 0.241 mg/L K760523 2 200 Lead ND mg/L K7G0692 200 Lead 0.256 mg/L 0059510 0.05 200 Copper 0,268 mg/L K7G0692 2 10 Zinc 0,255 mg/L 0059510 0.3 200 Notes and Definitions H Analytc was prepared andlor analyzed outside of the analytical method holding time State Certifications: NCDNK 411 NCDOH f137714 Respectfully Submitted Jeanne Overstreet. Project Manager Thank you for your business. We invite }vwr fec•dhack un oar lev'e! nfserwn 7o you. Please coniael the, DhAion dlanago. Rob Derwer at 910-864-1920 with am questions. You may also contact d. Trevor Bowe, President at president n:microhac.com Microbac Laboratories, Inc. Page 2 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f I www.microbac.com M1c-o''A. Fayetteville Division 2592 Hope Mills Road - Fayetteville, NC 28306 (910) 864-1920 / " " "- CHAIN CHAIN OF CUSTODY RECORD CLIENT NAME S ADDRESS: Pentair 188 Carolina Road PO PROJECT I LOCATION: Jul '17 Storm Water Monitoring co J m LL O TYPE OF ANALYSIS PRESERVATION (CODE) tc CL (j F a F N O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6"C D = NaOH + <6"C E = ZN Acetate + <6°C F = HCl G = Sodium Thio CONTACT PERSON` Mark Logue EMAIL: mark.loque@i3entair.com SAMPLED BY: Mark Logue PHONE NUMBER: 904-504-3040 DATE I METHOD OF SHIPMENT: LAB ID # SAMPLE TYPE DATE TIME COMP GRA� PH FLOW TEMP RES- C �oRMe SULFIDE [)� 01 Storm Water, 01 7/18117 6.45pm X aI' B A A Z 72 I Q� 02 Storm Water, 02 7/18/17 6:50pm X B A A C Z 7t ►1 I Lab Retie bY: t ate `7e (. Received : (Signature) 2 Date -11 Time jLfW2 Re' - Time Rec by:1 ' 1 4 Date one Nbwptshed by: 5 Date Ime 1 Received by:(Signature) 6 Daft Thme Initials Tumaround time: REGULAR RUSH Comments or Special Hazards: IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: P"'I ,� I Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 6/16/17 CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR —2017 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly' May (month) PERSON COLLECTING SAMPLES Mark Logue DISCHARGING TO CLASS ❑ORW ❑HQW [_]Trout ❑PNA LABORATORY Microbac Lab Cert. # _NCDNR#11 ❑Zero -flow [—]waterSupply [:]SA Comments on sample collection or analysis:_ Capper total analyzed bvREGEI v ED [:]Other Microbac Lab, Inc Ohio, Cert #583_ JUN 2 0 2017 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 5/29/17 0.20 132 6.3 0.498 <0.003 0.204 <5.00 N/A Outfall #2 5/29/17 0.20 74.2 4.9 0.485 <0.003 0.203 5.05 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). PP Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Garret Allee Name (Print name) PI nt tiVe) (Signature 06 16/17 (Date) Note: Results must be reported in numeri al fqxaraf. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z OutfalE No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: + A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reportsl to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 OMICROBAC- Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 06/14/17 Mr. Mark Logue Project: Slormwaler Samples Date Received: 05/31/17 188 Carolina Drive Date Sampled: 05/29/17 Aberdeen NC, 28315 Sampled By: Logue Storm Water 01, Grab K7E 1059-01 I Analyte Result Units Analyzed Analyzed By _ Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 0,498 nig/L 06/01/17 10:49 AC EPA 200.7 Rev 4.4 1994 Lead <0.003 nig/L 06/01/17 10:49 AC IPA 200.7 Rev 4.4 1994 Oil & Grease (SOT -HEM) <5.00 mg/L 06/01/17 08:54 JR EPA 1664 PH 6.3 pH Units 06/08/17 09:57 ELM SM 4500 H+B-2000 11 (Aqueous) Total Suspended Solids 132 mg/L 06/01/17 08:55 TAB SM 2540 D-1997 Zinc 0.204 mg/L 06/01/17 10:49 AC EPA 200.7 Rev 4.4 1994 Storm Water 02, Grab K7E 1059-02 Analyte Result Units Analyzed Analyzed By Method Qualifier � Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper <0.005 mg/L 06/01/17 10:49 AC EPA 200.7 Rev 4.4 1994 Lead <0.003 mg/L 06/01/17 10:49 AC EPA 200.7 Rev 4A 1994 Oil & Grease (SGT-FfEM) 5.05 rng/L 06/01/17 08:54 JR EPA 1664 PH 4.9 PH Units 06/08/17 09:57 ELM SM 4500 H+B-2000 H (Aqueous) Total Suspended Solids 74.2 mg/L 06/01/17 08:55 TAB SM 2540 D-1997 Zinc 0.075 mg/L 06/01/17 10:49 AC EPA 200.7 Rev 4A 1994 Storm Water 02, Grab (re -run) K7E 1059-03 I Analyte Result Units Analyzed Analyzed By Method Qualifier � Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 0.485 ntg/L 06/14/17 09:23 AC EPA 200.7 Rev 4.4 1994 Zinc 0.203 mg/L 06/13/17 13:41 AC EPA 200.7 Rev 4.4 1994 QC Batch Run - (Afierobac Laboratories, Inc. - Fayetteville) Analyte Result Units Source RPD Limit Lead ND mg/L K7E0970 200 Microbac Laboratories, Inc. Page 1 of 4 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f E www.microbac.com OMICROBAC ci, Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 06/14/17 Mr. Mark Logue Project: Stormwater Samples Date Received: 05/31/17 188 Carolina Drive Date Sampled: 05/29/17 Aberdeen NC, 28315 Sampled By: Logue QC Batch Run - (Microbae Laboratories, Inc. - Fayetteville) Analyte Result Units Source RPD Limit Lead 0.246 mg/L 0057273 1 200 Copper 0.252 mg/L K71,0973 2 10 Copper 0.256 mg/L K7E0970 1 10 Copper ND mg/L K7E0973 10 Copper ND mg/L K7E0970 10 Total Suspended Solids 1020 mg/L K7E 1082 19 5 Total Suspended Solids 53.0 mg/L K7E I049 2 5 Total Suspended Solids 8.86 mg/L K7E0994 6 5 Copper 0.246 mg/L 0057273 2 200 Zinc 1.06 mg/L K7E0973 2 10 Copper 0.017 mg/L K7F0366 14 10 Zinc ND mg/L K7F0260 10 Zinc 0.242 mg/L 0057711 1 200 pH 7.7 pH Units K7F0221 0 200 Copper 0.254 mg/L 0057749 0.1 200 Zinc 0.250 mg/L K7F0260 4 10 Lead ND mg/L K7E0973 200 pH 4.8 pH Units K7F0020 0 200 Zinc 0.304 mg/L K7E0970 0.9 10 Zinc ND mg/L K7E0973 10 Zinc 0.782 mg/L K7130970 170 10 Zinc 0.249 mg/L 0057273 0.2 200 Lead 0,268 mg/L K7E0973 3 200 Lead 0.249 mg/L K7E0970 0.2 200 Copper 0.262 mg/L K7F0366 2 10 Microbac Laboratories, Inc. Page 2 of 4 2592 Hope Mills Road I Fayetteville, NC 28306 1 910-864.1920 p 1910.864.8774 f I www.microbac.com OMICROBAC Fayetteville Division Certificate of Analysis Pentair Grico Intl. Corp. Date Reported: O61141t 7 Mr. Mark Logue Project: Stormwater Samples Date Received: 05/31/17 188 Carolina Drive Date Sampled: 05/29/17 Aberdeen NC, 28315 Sampled By: Logue Notes and Definitions H Analyte was prepared andlor analyzed outside of the analytical method holding time State Certifications: NCDNR #II NCDOH #37714 Respectfully Submitted \ I "�� 'Y. Honnic K, Sanders, Senior Project Manager Thank you for your business. We invite toter fi'edlwck on rater lrsx 7 ajsrezfea'rn tvu. Pleura• contact the• Lln irion :5&rnagt•r. Ruh IA'r-nt•r a 910-864- 1920 wish anp question.', kin, nroe also contact I Tress $nrce, President of presid •nl almicrohac.cont Microbac Laboratories, Inc. Page 3 of 4 2592 Hope Mills Road I Fayetteville, NC 28306 19110.864.1920 p 1910.864.8774 f I www.microbac.com (!5)MICR08AC' Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-1920 / 864-87" `"K7E1059' CHAIN OF CUSTODY RECORD CLIENT NAME E ADDRESS: 1 Pentair 188 Carolina Road PON PROJECT rtocnnoNc May '17 Storm Water Monitoring w 0 U. (a fl TYPE OF ANALYSIS PRESERVATION (CODE) N ii j In A W tn CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6°C E = ZN Acetate + <6°C F = HCj G = Sodium Thio carracrPERsoH: Mark Logue EMAIL: mark.loque(@oentair.com SAMPLED BY: Mark Logue PHONE NUMBER: 904-504-3040 DATE I METHOD OF SHIPMENT: LAB ID # SAMPLE TYPE DATE TIME COMP GRAB PH FLOW TEMP •C CHLORINE SULFME 01 Storm Water, 01 5/29/17 9:20pm X 1 B A A I C I Z (°� 02 Storm Water, 02 5129117 9:30pm X 1 B A A 74 C Ii rh Lab Initials---w Turnaround time: Roil by: ime RecdKed by: (Signature) Date rime 2 3t-i) Reim by: 3 Date 5-3 i-)j Ime 1604,— R-gnature) 1 a Date 31-17 Time !(,: ellnttuished by: Date Time Received by: jSignature) Date Ime 5 5 REGULAR RUSH Comments or Special Hazards: R` JiTVV—t;D IS DATA FOR REG. C MPLIANCE PURPOSE? NO YES joO' WHICH. Page 4 of 4 I ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. May 10, 2017 i Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: Phone: 1-910-944-3355 Fax: 1-910-944-3418 www.erico.com C: MIRY 19 2011 C.ENT-RAL f=ILES DWR SECTION Please find enclosed the updated Discharge Monitoring Report (DMR) for April 2017 for the ERICO facility referenced above. The initial DMR, also submitted on May 10, 2017, was signed incorrectly under Part B: Vehicle Maintenance Area Monitoring Results. The updated DMR has been signed correctly under Part A: Stormwater Benchmarks and Monitoring Results. If you have any questions, please don't hesitate to call me at (910)-944-4127. Sincerely, A�—� I Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8977 2295 CADDY® • ERICO® • ERIFLEX® • ERITECN® • LENTON® Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5/5/17 CERTIFICATE OF COVERAGE No. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Mark Logue LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' April (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []zero -flow []WaterSupply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches" Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L i mg/L Outfall #1 4/3/17 0.60 58.2 6.3 0.858 <0.003 0.183 <5.00 N/A Outfall #2 4/3/17 0.60 16.8 5.9 0.375 <0.003 0.075 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. A See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." 7- 46-erzr Name (Print name) Title ( /d Zo/7 (Date) Note: Results must be reported in nu eri ormat. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B. Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results Lor at end of monitoring period in the case o "No Dischar e" reports) to: Division of Water Quality -- Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date: 11/1/2012-10/31/2017 [Date] SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 3/28/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio. Cert #583__ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' March (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVED ❑Zero -flow ❑Water Supply ❑SA ❑Other APR 0 5 2017 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES CWR SECTION No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 3/1/17 0.75 214 5.6 4.52 0.022 0.923 <S.00 N/A Outfall #2 3/1/17 0.75 149 5.1 1.14 <0.003 0.406 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Title (Print title) Z8 /ZIP/'7 — (Sign (Date) Note: Results must be reported in nu erical format. of re ort Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the ap units, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period:' Outfall No. Date Sample Collectedl (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =_=> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. �• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawver Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt.of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there ap j ificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ure of Permitteej Permit Date: 11/1/2012-10/31/2017 :�A-7—ff/Zo/ 7 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Pentair Erico Intl. Corp. Mr. Mark Logue 188 Carolina Drive Aberdeen NC, 28-115 (�)MIICROBAC Fayetteville Division Certificate of Analysis Project: Sturmwater Samples Storm Water 01, Grab K7C0074-01 Dale Reported: 03117/ 17 Date Received: 03/02/17 Date Sampled: 03/01/17 Sampled By: Logue Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac laboratories, Inc. - Fayetteviile Copper 4.52 mg/L 03/09/17 12:16 AC EPA 200.7 Rev 4A 1994 Lead 0.022 ntg/L 03/07/17 11:41 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-Iirkl) <5.00 nig/L 03/14/17 06:28 JAW t EPA 1664 pl l 5.6 PH Units 03/07/17 10:30 ELM SM 4500 11+13-2000 11 (Aqueous) Total Suspended Solids 214 mg/L 03/03/17 09:22 JR SM 2540 D-1997 Zinc; 0.923 mg/L 03/07/17 11:41 AC EPA 200.7 Rev 4.4 1994 Storm Water 02, Grab K7C0074-02 Analyte Result Units Analyzed Analyzed By Method Qualifier Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 1.14 mg/L 03/07/17 11:41 AC EPA 200.7 Rev 4.4 1994 Lead <0.003 mg/L 03/07/17 11:41 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-I-IEM) <5.00 mg/L 03/14/17 06:28 JAW EPA 1664 pll 5.1 pi l Units 03/07/17 10:30 ELM SM 4500 1I+13-2000 11 (Aqueous) Total Suspended Solids 149 mg/L 03/03/17 09:22 JR SM 2540 D-1997 Zinc 0.406 mg/L 03/07/17 11:41 AC EPA 200.7 Rev 4.4 1994 QC Batch Run - (1licrahar l.ahuratories, lne. - Fay-etteeille) Analyte Result Units Sourer RPD Limit phl 6.0 pi l Units K7C0095 0 200 Copper 0.238 mg/L K7C0113 0.8 10 Copper 0.366 nig/L KX0051 2 10 Copper 0.002 mg/L K7C0113 8 10 Copper 0.144 mg/L K7C005I 8 10 Lead ND mg/L K7C0051 200 Lead ND mg/L K7C0113 200 Total Suspended Solids 47.0 mg/L KX0095 16 5 Microbac Laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910,864.8774 f I www.microbac.com Fayetteville Division 2592 Hope Mills Road - Fayetteville, NC 28306 (910) 864-19201 ODMICROBAC CHAIN OF CUSTODY RECORD CLIENT NAME & ADDRESS: Pentair 188 Carolina Road roan PROJECT I LOCATION; iMarch'17Stormwater Sample ul O m O TYPE OF ANALYSIS PRESERVATION (CODE) .N U) ',F, 1:L }.., O CODE: A = None B = HNO3 (pH<2) + <6°C C = H2SO4 (pH<2) + <6°C D = NaOH + <6°C E = ZN Acetate + <VC F = HCl G = Sodium Thio CONTACT PERSON: Maria Lowe EMAIL: mg to ue entair:com SAMPLED SY: Mark Logue PHONE NUMBER: 904-504-3040 DATE I METHOD OF SHIPMENT: LAB ID # SAMPLE TYPE i DATE TIME COMP GRAB PH FLOW TEMP"C CHLORINE SULFIDE tilt G Storm Water, 01 311117 9:45pm X 1 *B A A 'C Storm Water, 02 311117 9:45pm X 1 B A A C L Lab Relinq ' Date �Z Time lll��/li Recei� by: {Signature Date J -2-l7 Time 2 Relin Shad b . Date / Time R i y; (Signature) Daaatte '7 Time L la Relinquished by: m Received by: [SigrMturey Date Time fate 6 Initials--* Turnaround time: REGULAR RUSH Comments or Special Hazards: iS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 -C Date submitted 3/14/17 CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR _2017 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly' February (month) PERSON COLLECTING SAMPLES _Frank Bryant DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY Microbac Lab Cert. # NCDNR#11--REV E1 V E[) ❑Zero -flow [:]WaterSupply [:]SA Comments on sample collection or analysis:_ Copper total analyzed by ❑Other Microbac Lab, Inc Ohio, Cert #583 MAR 2 3 207 CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Totak Total Petroleum Hydrocarbons Toxic Organ ics5 . Benchmarks ===> _ - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2/15/17 0.75 33.7 5.3 1.28 0.024 0.206 <5.00 N/A Outfall #2 2/15/17 0.75 52.7 5.0 1.33 0.012 0.351 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain -gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: - "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." 7- 146eCr Name (Print name) Title (Print 7 (Date) Note: Results must be reported in nu erical Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15.mg/L 100 mg/L or 50 mg/L* 6.0 - 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawver Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are5igVicant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ature of Perm 3 / /7 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 0MICROBAC`' Fayetteville Division Certificate of Analysis Pentair ETiCo Intl, Corp. Mr. Frank Bryant Project: Sturmwater Samples 188 Carolina Drive Aberdeen NC, 28315 Storm Water Site #I, Grab K7130644-01 Date Reponcd: 03/03/17 Date Received: 02/17/17 Date Sampled: 02/15/17 Sampled By: Bryant I Analyte Result Units Analyzed Analyzed By Method Qualifier Field Data Temperature 6.7 °C 02/15/17 09:05 Bryant Field Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 1.28 mg/L 03/01/17 11:59 AC EPA 200.7 Rev 4.4 1994 Lead 0.024 nig/L 03/01/17 11:59 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-IIEM) <5.00 nig/L 02/27/17 20:20 JAW EPA 1664 p11 5.3 PI Units 02/24/17 14:00 ELM SM 4500 11+13-2000 11 (Aqueous) Total Suspended Solids 33.7 ntg/L 02/22/17 07:55 JR SM 2540 D-1997 Zinc 0.206 mg/L 03/01/17 11:59 AC EPA 200.7 Rev 4.4 1994 Storm Water Site #2, Grab K7110644-02 Analyte Result Units Analyzed Analyzed By Method Qualifier Field Data Temperature 6.7 °C 02/15/17 09:12 Bryant Field Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 1.33 mg/L 03/01/17 11:59 AC EPA 200,7 Rev 4.4 1994 Lead 0,012 mg/L 03/01/17 11:59 AC EPA 200.7 Rev 4.4 1994 Oil & Grease (SGT-I IEM) <5.00 mg/L 02/27/17 20:20 JAW EPA 1664 p11 5.0 pl I Units 02/24/17 14:00 ELM SM 4500 1 I+B-2000 I I (Aqueous) Total Suspended Solids 52.7 mg/L 02/22/17 07:55 JR SM 2540 D-1997 Zinc 0.351 mg/L 03/01/17 11:59 AC EPA 200.7 Rev 4.4 1994 QC Batch Run - (al;rr„ear Laboratoricv, Inc. - Fayetteville) Analyte Result Units Source RPD Limit Copper 1.24 mg/L K7B0644 7 10 Copper 0.265 mg/L K7B0564 4 10 Copper 0.278 mg/L K7B0563 4 10 Microbac Laboratories, Inc. Page 1 of 4 2592 Hope Mills Road I Fayetteville, NC 28306 1910.864.1920 p 1910.864.8774 f I www.microbac.com �VMICROBAC Favetteville Division Certificate of Analysis Pentair Erico Intl, Corp. Date Reported: 03/03/17 Mr. Frank Bryant Project' SturniNvater Samples Date Received: 02/17/17 188 Carolina Drive Date Sampled: 02/15/17 Aberdeen NC, 28315 Sampled fay; Bryant QC Batch Run - (.tlicrnbac Laboratories, Inc. - Fayetteville) I Analyte Result Units Source RPD Limit f Copper ND mg/L K7130807 10 Copper 0.010 mg/L K7130564 1 10 Copper 0.033 mg/L K7130563 3 10 Copper 0.270 mg/L 0053550 2 200 Capper 0.275 mg/L 0053550 t 200 Copper 0.231 nig/L K7130807 7 10 PH 5.0 plI Units K7130846 0 200 PH 6.6 p11 Units K7130840 0 200 pl-1 6.0 p11 Units K7130599 0 200 Total Suspended Solids 360 mg/1' K760670 5 5 Total Suspended Solids 560 mg/L K7130669 27 5 Total Suspended Solids 53.0 mg/1- K7130644 0.6 5 Total Suspended Solids 12.0 mg/L K7BD6i4 3 5 Zinc 0.349 mg/L K7130644 0.7 10 Lead 0.011 mg/L K7B0644 9 200 Zinc 0.614 mg/L K7130644 3 t0 Zinc 0.295 mg/L K7130564 2 10 Zinc 0.734 mg/L K7130563 3 10 Zinc 0.257 mg/L 0053350 2 200 Lead 0.267 rrtg/L K7130807 5 200 Lead 0.023 mg/L K7130807 0 200 Copper L57 mg/L K7B0644 1 ID "Zinc 0.277 ntg/L K760807 6 10 Zinc 0.027 mg/L K7B0807 6 10 "Zinc 0.068 mg/L K7B0564 23 10 Zinc 0.491 mg/L K760563 8 10 Zinc 0.249 nig/L 0053550 0.4 200 Lead 0.255 mg/L K7130644 2 200 Lead 0.249 mg/L K7130564 2 200 Microbac Laboratories, Inc. Page 2 of 4 2592 Hope Mills Road j Fayetteville, NC 28306 1 9%864.1920 p 1910.864.8774 f I www.microbac.com Pentair Erica Intl. Corp. Mr. Frank Bryant 188 Carolina Drive Aberdeen NC, 28315 6)MICROBAC' Fayetteville Division Certificate of Analysis Project: Stormn•ater Samples QC Batch Run - (VicrobacLubaratoricr, Im.-Faymer'ille) Date Reported: 03/03/17 Datc licccivcd: 02/17/17 Date Sampled: 02/15/17 Sampled By: Bryant I Analytc Result Units Source RPD Limit Lead 0.264 mg/L K7B0563 4 200 Lead 0.012 mg/L K7B0564 9 200 Lead 0.041 mg/1' K7B0563 9 200 Lead 0.241 mg/L 0053550 0.8 200 Lead 0.251 mg/L 0053550 2 200 Notes and Definitions 11 Ana lyie was prepared andfor analyzed nut5ide of the analytical method holding 611w State Certi fications: NCDNR # 11 NCDOH 437714 Respectfully Submi�ttcd Jeanne Overstrcel, Project Manager Thank you for your business. Wr irnirr ytnrrJc•edb<rck un um Irvr! uJ'srnvice' fu rrru, 1'lerrse' currluc 1 drr Diririun .1lwmger, Huh Uerrver ut 9lfl-8bd-! 9'!1 rrillr <en_v yrre�tians. Ynu murulao confucl J. Trecor Burry, Presidrn! ur yrrtiidcnr �neicraheec.rum Microbac Laboratories, Inc. Page 3 of 4 2592 Hope Mills Road I Fayetteville, NC 28306 1 910.864.1920 p 1 910.864,8774 f I www.microbac.com Favotwvtlit: Pimsion 2',92 hope i tills ROBO — POYM c. We, Nc _'8306 ;t(,.: CHAIN OF CUSTODY RECORD CULrtT NAME& ADORES:; FI ICU v'8 Corcillla []I lvr• Aburdoon, NC ?b; I POP PROJtCl'L0CAliO:,. J:Or1'T1V•'3tF.'i -OF t; :1 } F TYPE OF ANALYSIS PRESERVATION CODE w r'� Ui i•. (3,1 � Q th cd CI L'UI)t`- ;, = Num, If -- I iricn j(li l•_.71 r . ,}•.t. . -'r' icy; (plt 1J:1C'}I f • 1., � _ ,'r�J4C?I:IIn r r:•i, 11(:I CUNIA!-.I PLRbO:: r1r11 i-;.Stnk Islvan, PliOW_ yl SGr•1PLLIi_ Js r i UA1l.IMLlfi0UO1-SHIpMLNI: 1jIL'rOJ3 LAB IDV i SAMPLE TYPE DATE TIME CGrd• GRAti 10Ji11 uu IkMI'"1: clli.aszkr�t 1 1 ZI�SIi1 1 O� ' ;;Gf 111 tJ Lr[=lr:', Site 2 2 I + 517 7 M •• J3 f I r� r6 I .A z C Z I i I i7A !in ili nnl �k by, Jn4• �xx,•/4 RnS;j.VxJ I,Y: I$lIII1J1111•�1 o;fl„ }�Ip.r F„jimp :hnJ Icy. 0„t.• �` Tirn•• lro� R�cnlv�r .ISinrmhlr.p Q A D:11„ 2 7 r7 Tln+. I I U� Rnl .lml.}sxd=rv- D.o-- Pm•• R...."d by:ISlgnaivra Duln 17,­ I IG i ;nrrSlttn;t(:, rir `�Drra;li ri,tllyd•. r 7 17 ry � �c�i �rcd F•�'`M'�. � Page 4 of 4` Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 2/27/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583� Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly" January (month) DISCHARGING TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA []zero -flow ❑Water Supply ❑SA ❑Other RECEIVED MAR 0 i � l! i l PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION' ❑ No discharge this period: Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ . Total Petroleum Hydrocarbons Total Toxic 5 Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 1 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 01/21/17 0.25 18.0 5.6 0.359 <0.003 0.106 <5.00 N/A Outfall #2 No Sample N/A i Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. a The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) �1��7-yl.9�go-c�.� Title (Prin ignature) (Date) Note: Results must be reported in num9fical forma -v—o not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the ap fe-fimits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part 8: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 .Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text, FOR PART A AND PART 8 MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. + 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results (or at end of monitoring period in the case o "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons direct) ponsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th e a significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ature of Pe Permit Date: 11/1/2012-10/31/2017 Z T i7 (Dat SWU-245, last revised 10/25/2012 Page 3 of 3 �MICROBAC` Fayetteville Division Certificate of Analysis Pentair Erico Intl. Corp. Date Reported: 02/03/17 Mr. Frank Bryant Project: Stormmrater Samples Date Receive(!: 01/24/17 188 Carolina Drive Date Sampled: 0 1/2 1/17 Aberdeen NC, 28315 Sampled 13y: Bryant Storm Water Site #1, Grab K7A0788-01 Analyte Result Units Analyzed Analyzed By Method - Qualifier_ Analyzed by: Microbac Laboratories, Inc. - Fayetteville Copper 0.359 mg/l- 01/30/17 12:32 AC EPA 200.7 Rev 4.4 1994 Lead <0.003 mg/L O1/30/17 12:32 AC EPA 200.7 Rev 4A 1994 Oil & Grease (SGC-ITEM) <5,00 mg/L 01/30/17 20:15 JAW EPA 1664 PH 5.6 pl I Units 02/02/17 11718 ELM SM 450011+13-2000 11 (A(lueous) Total Suspended Solids 18.0 mg/L 01/25/17 10:12 JR SM 2540 D-1997 Zinc 0.106 mg/L 01/30/17 12:32 AC EPA 200.7 Rev4.4 1994 QC Batch Run - (Ifirrohar Laboratories, tnc, - Pay-erreville) Analyte Result Units Source Rill) Limit Copper 0.250 Ing/L 0052438 0.4 200 Copper 0.243 mg/L K7A0945 5 10 Copper 0.619 nig/L K7A0788 4 10 Copper 0.327 mg/L K7A0685 2 10 Copper 0.231 mg/L K7A0685 0.4 10 Copper 0,013 mg/L K7A0945 17 10 Copper 0,365 mg/L K7A0788 2 10 Copper ND mg/L K7A0685 io Lead ND mg/L K7A0685 200 Copper 0.269 mg/L 0052438 0.7 200 Total Suspended Solids 6.40 mg/L K7A0857 13 5 Total Suspended Solids 86.7 mg/L K7A0837 18 5 Total Suspended Solids 168 mg/L K7A0836 4 5 Zinc 0.106 mg/L K7A0788 0 10 Lead ND mg/L K7A0788 200 Copper 0.058 mg/L K7A0685 5 10 Zinc 0.646 mg/L K7A0945 3 10 Zinc 0.338 mg/L K7A0788 1 10 Microbac laboratories, Inc. Page 1 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1 910.864.1920 p 1 910.864.8774 f I www.microbac.com w �VMICROBAC" Fayetteville Division Certificate of Analysis Pentair Grico Intl. Corp. Date Reported: 02/03/17 Mr. Frank Bryant Project: Stormtsater Samples Date Received: 01/24/17 188 Carolina Drive Date Sampicd: 01/21/17 Aberdeen NC, 28315 Sarnpled Iffy: Bryant QC Batch Run - (Microbac 1 uhoraruries, Inc. - Fupertevilit) Analyte IZcsult Units Sourcc RPD Limit 7-inc 0.252 mg/L K7AO6S5 0.8 10 Zinc 0,416 mg/L K7A0945 2 10 Zinc ND mg/L K7AO685 10 Zinc ND mg/L K7AO695 10 Lead 0.201 mg/L K7AO945 3 200 Lead 0.207 mg/L K7A078S 0.5 200 Lead 0.205 mg/[- K7AO685 2 200 Lead 0.202 mg/L K7AO685 5 200 p11 5.9 pl I Units K7AO980 0 200 Lead 0.234 mg/L 0052438 0 200 Lead 0.235 mg/1- 0052438 0 200 Zinc 0.245 fng/L 0052439 0.4 200 Zinc 0.287 mg/L 0052439 10 200 Lead ND mg/L K7AO945 200 Lead ND mg/L K7AO685 200 pl [ 7.0 p1 l Units K7AO979 0 200 Zinc 0.264 mg/L K7A0685 3 10 Notes and Derinitions I Analyte was prepared andlor analyzed outside of the analytical method holding time State CCrllfieinlUn5: NCDNR #II NCDOIi #37714 Rcspccifully Submitted 1'1\6a- '&e— Jeanne Overstreet, Project Managcr Thank you for your business. We mv-a you -jeedback on pea' level Oj SenLic e to coo. Please umtuet the Division Slanager, keel, Deriner al 910-864-19211 cvilh anv quesYioa,. line melt• also coulacr J. 7recnr 8uvice. P ntdenr at lureidenl gnuc'ru6uc.com Microbac Laboratories, Inc. Page 2 of 3 2592 Hope Mills Road I Fayetteville, NC 28306 1910.8641920 p 1910.864.8774 f I www.microbac.com L)lv:".i(l:) Hope %1015 1:m!o - Fa,,,t.qlt2vJlt:, NE *K7A0788- CHAIN OF CUSTODY RECORD CUUNT NAML & ADORESS. [PC,; I�FOJEXI I LOCA710K. I F.1 I [m 5 i o i P. c. r ,f86- C:J:ohfliA D11%,12 JLI�11.111LIIIIIDOI 5"lPMFNl7- fvllt:l o!)ac r ko u L TYPE OF ANALYStS PRESERVATION (CODE) ul h)W' kp) LAB 10 l I SAMPLE'l YPL-' UATL TIME GRAD c 111 n 'vV I.[' i. '.i It i: 7 Z., V-'- V A ' 73i I T1 LIE , 2V -17 To,— 13,YS R,.len 1w.h.0 hy. Tj.-, R.—.—d h%: DA.. T.— �j —1 (1 w CAC EVVE D Page 3 of 3 ERICO International Corporation 19 Carolina Road Aberdeen, NC 28315 U.S.A. December 11, 2017 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCGO30627 To Whom It May Concern: Phone: 1-910-944-3355 Fax: 1-910-944-3418 www.erico.com RFr'Pl1/FCC JAN 0 9 2018 1)1,,%C;Ti0N CtiEOR RATION PROXESSING UNIT Please find enclosed the Discharge Monitoring Report (DMR) for November 2017 for the ERICO facility referenced above. There was no discharge during the month. If you have any questions, please don't hesitate to call me at (910)-944-4127. Sincerely, 7- A/ Mark Logue, CSP Environmental, Health, and Safety Manager Certified Mail: 7016 2140 0000 8977 2431 CADDY® • ERICO® • ERIFLEX® • ERITECH® - LENTOO Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/8/17 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Mark Logue LABORATORY Lab Cert. # Comments on sample collection or analysis:_ Click here to enter text. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2017 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Z Monthly' November (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ® No discharge this period?Z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks ===> _ . - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 N/A Outfall #2 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. 1 further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Peter Hannis Name (Print name) Interir lIant Manager Titl�ritlt } ' 12/11/17 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected` (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Semi-annual Stormwater Discharge Monitoring Report AZ,> for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 1/18/2017 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 _ iAS,ACcohl SAMPLE PERIOD ❑ Monte ❑ !y7dd# k_ Ef V CD ® monthly' December �A� 2 2017 DISCHARGING TO CLASS ❑ORW ❑HQW [—]Trout❑P11]A' ❑Zero -flow ❑Water Supply ❑SA CENTRAL FILES ❑Other aWR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period: Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic 5 Organics Benchmarks =__> _ 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall 41 12/4/16 1 13.7 8.5 0.191 <0.003 0.093 <5.00 N/A Outfall #2 12/4/16 1 2.20 7.4 0.045 <0.003 0.109 <5.00 N/A a Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Name (Print name) PL.gOOVT �•��9 C�[�2 Title (Print n r (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be resorted in the format, "<XX mg[L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inche53 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Nate: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • - A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART 13 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of recei t of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete, am aware thajtlrerelare significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/27/2016 CERTIFICATE OF COVERAGE NO. N00030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly) November _ (month} DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA RECEIVED ❑Other DEC 2 9 2016 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?z Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 11/29/16 1 24.0 7.4 0.582 <0.003 0.283 <5.00 N/A Outfall #2 11/29/16 1 6.00 6.7 0.390 <0.003 0.196 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. S Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." G�g/gtT -T .4&-&-c=- Name (Print name) f LAST' lrJ� Title (Print rir1 iPk (Sign / Z L7 (Date) Note: Results must be reported in numerical fo amr t. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) ta: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons d ectly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there a}e significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permit Date:11/1/2012-10/31/2017 /Z147 14 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _11/03/2016 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Copper total analyzed by Microbac Lab, Inc Ohio, Cert #583 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec _ or ® Monthly' October (month) I CHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA IVIED ❑Zero -flow [:]WaterSupply ❑SA NOV 0 7 2016 ®OtherUnable to analyze_ CENTRAL FIL PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DwR SEC71C)fV ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 10/07/16 1 16.8 7.11 0.0562 <0.003 0.089 Other N/A Outfall #2 10/07/16 1 5.6 6.12 1.03 <0.003 0.193 <5.00 N/A �11IQ0 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469,22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waiver. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit...For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Ti /l 3 // (Date) Note: Results must be reported in numericaTformat. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mglV', where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ==_> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART it SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons direr I responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware th er re significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ittee} Permit Date:11/1/2012-10/31/2017 zz!v (Da } SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 10-07-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES —Patrick Hailey/Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:— Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' September (month' DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA RECEIVED [-]Other OCT 12 2015 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?z Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics s Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 9-19-16 1.0 4.0 7.0 0.141 <0.003 0.064 <5.00 N/A Outfall #2 9-19-16 1.0 6.4 6.2 5.03 <0.003 0.366 <5.00 N/A 1 Monthly sampling (instead of semi-annual) trust begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." T 46zf� Name (Print name) Title (Print titj�E� gnature) (Date) Note: Results must be reported in numeric I for not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' putfall Na. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr, Mike Lawyer Mail an original and one copy of this DMR� including all "No Discharge" reports within 30 days of receipt o/the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly onsIN for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that th9t6aregnificant penalties for submitting false information, including the possibility of fines and imprisonment for Knowing violations." (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 1 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore) PERSON COLLECTING SAMPLES _Patrick Hailey_ Date submitted 9-23-16 LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:— Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' August— month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA [RECEIVED ❑Other SEP 2 8 Z016 PLEASE REN�1 T N ON PAGES 2 AND/OR 3 4 CENTRAL FILES O DR SECTION ❑ No discharge this period Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 8-17-16 0.15 16.0 6.8 0.734 <0.003 0.289 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." C �'f i 7-t.'e2's- Name (Print name) (Date) Note: Results must be reported in numericaNefmaf-Do not resort Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. see General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. [] No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 Su Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly r ponsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that theignificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." z� r6 (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/2S/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 8-22-16 h CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 20165/ SAMPLE PERIOD ❑ Jan -June ❑ Jutwo or ® Monthly' August d=, (month) DISCHARGING TO CLASS ❑ORW ❑HQW UTrout ❑PNA ❑Zero -flaw �W� `Supply [:]SA DECEIVED ❑Other AUG 2 3 2016 PLEASE REMEMBER TO SIGN ON PAGE AND/OR 3 4 CENTRAL FILES DWR SECTION ® No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 Outfall #2 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. Vor those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." A<9dr r Name (Print name) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 sU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERSTIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th.9r*;bre significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 8 7- ib (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 6-9-16 CERTIFICATE OF COVERAGE NO. N00030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Mykela Marshall LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' May (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA _ ❑Zero -flow [—]Water Supply ❑SA RECEIVED ❑Other JUN 2 7 2016 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids PH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 S-17-16 0.25 16.6 6.4 0.544 <0.002 0.196 <5.00 N/A Outfall #2 5-17-16 0.25 4.80 6.5 0.267 <0.002 0.102 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." T Name (Print name) Title (Printlj�W) (Signature (a Z/ /6 (Date) Note: Results must be reported in umerical fo mat�Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the app icable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' [mo/dd/yrj 24-hour rainfall amount, 3 inches Non -polar O&G/TPH by EPA 1664 [SGT-HEM) Total Suspended Solids PH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 2 of 3 Note, if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FO,R PART A AND PART 8 MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. + TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer _ _ Mail an original and one copy pf this DMR, including all "No Dischar, ece"" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware t th re are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Ll� (Sign re of Perms (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000A Date submitted 7-11-16 44e, CERTIFICATE OF COVERAGE NO. NCG030627 SAMPLE COLLECTION YEAR _2016 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ®Monthly' June moat PERSON COLLECTING SAMPLES _Frank Bryant D15CHARGING TOICLA55 ❑ORW ❑HQW ❑Trout ❑PNA' LABORATORY Microbac Lab Cert. # _NCDNR#11 'f' ❑Zero -flow [-]Water Supply [:]SA Comments on sample collection or analysis:_ Outfall #1 & Outfall # ECEI1 iEE, f ❑Other samples were taken after a dolomite lime check dam was installed V /f prior to each outfall_ JUL Z 3 �� f G PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILEc Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks ===> - - 100 mg/L or 5D mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 6-15-16 1.5 15.2 6.3 0.276 <0.003 0.094 <5.00 N/A Outfall #2 6-15-16 1.5 6.8 6.0 6.25 <0.003 0.206 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 see General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Title {Print t' ( natur 7 1/ / (Cate) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. F6R PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results (or at end of monitoring period in the case o "No Dischar e" reports) to: Division of Water Quality Attw DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons dlteety responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware �W theref6re si cant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permi (Da(e) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore R PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:— Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 N- SAMPLE PERIOD ❑ 1an-June ❑ July -Dec. or ® Monthly' April month DISCHARGING TO CLASS ❑ORW ❑HQW � Trot ❑PNA CC ��� QZero-flow ❑Wate/%SSup [:]SARGC❑Other � MAY 2 4 201b ,r/ � PLEASErREMEMBER TO SIGN ON PAGES 2 AND/O --> CENTRAL FV DWR SE& ❑ No discharge this period: Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, IncheS3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 4-1-16 0.20 29.6 7.4 0.378 <0.003 0.164 <5.00 N/A Outfall #2 4-1-16 0.20 4.50 6.8 0.115 <0.003 0.083 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirementto sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 swu-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Title (P titl (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be re orted in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (5GT-HEM) Total Suspended Solids pH Benchmarks ===> _ 15 mg/L 100 mg/L or 5o mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 4, . Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. Is TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case o "No Discharge" re arts to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly res onsibie for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that ther a sig ficant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." re of Perm (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' March (month) JRE@LP& TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA []Zero -flow ❑Water Supply ❑SA MAY 2 4 2016 ❑Other CENTRAL FILE DWR SECTIO(�LEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 ® No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 Outfall #2 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �Cec r Name (Print name) Title (Print (Signature) (Date) Note: Results must be reported in num al far report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. (Vote: if you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 5U Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of lob results (or at end of monitoring period in the case o "No Discharge" reports to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, !North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that V7rc" are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Z3 i� (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 r a ' Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results 5-17-16 SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June 0 July -Dec or ® Monthly' February (mo_rrthi DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply []SA RECEIVED ❑Other MAY 2 4 Nib PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 CENTRAL FILES DWR SECTbN ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2-3-16 1.75 96.5 6.5 1.25 0.008 0.550 <5.00 N/A Outfall #2 2-3-16 1.75 8.80 5.7 0.161 <0.003 0.089 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 1 of 3 Factities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." G T 4reZ- Name (Print name) RG9;,IVT Title (Pii it 1� (Date) Note: Results must be reported in numericdt'fEFIF—mat. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Qutfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Nare: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. R PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART If SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th are s nificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 5-12 J� (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No.,NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2016 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' January (month) R E CFPIDING TO CLASS ❑ORW ❑HQW [-]Trout❑PNA ❑Zero -flow ❑Water Supply ❑SA MAY 2 ❑Other CENTRAL WR� CTroN PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ® No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 Outfall #2 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22,- and for cathode ray tube manufacture use the definition found in 40 CFR 469.31), Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 ANOV Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." `l O n Name (Print name) Title (Pri it Z241L.4�_ (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Air Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. -FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy 91 this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" reports to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of 05-- Z Z — / (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 f /1 Date submitted 7-31-15 1 . CERTIFICATE OF COVERAGE NO. NCG030627 RECEI V ED.SAMPLE COLLECTION YEAR —2015 FACILITY NAME ERICO International Corporation AUG 0 4 2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore or ® Monthly'_ _ January (month) PERSON COLLECTING SAMPLES _Frank Bryant CENTRAL FILES DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY Microbac Lab Cert. # _NCDNR#11 WR SECTION ❑Zero -flow [:]Watersupply [:]SA Comments on sample collection or analysis:— Outfall #1 & Outfall #2 ❑Other samples were taken after a dolomite lime check dam was installed PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0,007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 1-23-15 0.3 10.0 7.3 0.864 0.007 0.344 2.13 N/A outfall #2 1-23-15 0.3 5.0 7.1 0.918 0.175 0.022 1.37 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit' ) (Signature} (Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 2of3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an on final and one copy of this DMR including all "No Discharge" reports, within 30 days of recei t of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." [Signature 71,51 //j (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant_ LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results 7-31-15 SAMPLE COLLECTION YEAR _2015 I+( AMPLE PERIOD ❑ Jan -June ❑ July -Dec GEJVEo� ® Monthly' February (month) ATCkiAil DING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA UI� q2015❑Zero-flow ❑Water Supply ❑SA CEN7-RAL FILES ❑Other DWR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks 100 mg/L or 50 mg1C 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2-9-15 0.5 3.40 7.7 0.159 <0.003 0.073 <5.00 N/A Outfall #2 2-9-1s 0.5 13.2 7.8 0.489 <0.003 0.179 <5.00 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the 5tormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print titl 3 r� (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table S, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 No If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDANCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Pe -7/V S (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 7-31-15 CERTIFICATE OF COVERAGE NO. NCG030627 Rece j� � PLE COLLECTION YEAR _2015 FACILITY NAME ERICO International Corporation SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Moore AUG >? t5 or ® Monthly' March _ (_month PERSON COLLECTING SAMPLES _Frank Bryant CENT DISCHARGING TO CLASS ❑ORW ❑HQW [:]Trout ❑PNA LABORATORY Microbac Lab Cert. # _NCDNR#11 WR CTlCPILN ❑Zero -flow ❑Water Supply ❑SA Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 ❑Other samples were taken after a dolomite lime check dam was installed PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 3-30-15 0.15 7.20 7.1 0.238 <0.0015 0.104 <5.00 N/A Outfall #2 3-30-15 0.15 10.4 7.2 0.406 <0.005 0.139 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. A See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement forTTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print titl ) 3 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART Il SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Petmittee) -7/� l AS (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Re ort for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:— Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results 7-31-15 SAMPLE COLLECTION YEAR _2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec Rlicelvc or ® Monthly' '.April month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA �I T1U1.5❑Zero-flow [:]WaterSupply ❑SA CENTRAL Fl�EB [:]Other 0 VR SEC PON PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 4-25-15 0.25 9.54 6.6 0.425 <0.0015 0.130 <5.00 N/A Outfall #2 4-25-15 0.25 2.63 7.0 0.328 <0.0015 0.148 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), i certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Pr/,;a I� (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 - r Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports] to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of -7 ' /31 5 (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 7-31-15 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant_ LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2015 _ SAMPLE PERIOD ❑ Jan -June ❑ July -Dec REC or ® Monthly' May (month) D SCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA AUG U 4 2015 ❑Zero -flow ❑Water Supply []SA CENTRAL- FILES ❑Other DWR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks =__> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 1S mg/L 1 mg/L Outfall #1 5-21-15 0.30 28.0 6.5 0.502 <0.0015 0.229 <5.00 N/A Outfall #2 5-21-15 0.30 35.2 6.2 43.6 <0.0015 2.52 <5.05 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility'subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit-11,13 IVA"� 71& (Signature) (Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an on lnal and one copy of this DMR includin all "No Discharge" reports, within 30 days of receipt of the lab results jor at end of monitoring eriod in the cased "No Discharae" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Perm 7Z2 5 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results 5-17-16 SAMPLE COLLECTION YEAR _2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' June (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA RECEIVED ❑Other MAY 2 4 201f LEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 CENTRAL FILES DWR SECTION ® No discharge this period:2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 Outfall #2 F- 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwatter Pollution Prevention Plan." Z�/I� - '.5 A/ rrO _/'1 Name (Print name) Titlee((Pri t title) [."�>i7tir.>�--tZZ n r (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfatl No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART It SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) O 5 —2 Z — /Z, (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. N00030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results 5-17-16 SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD [:])an -June ❑ July -Dec or ® Monthly' July (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flaw ❑Water Supply [_]SA RECEIVED ❑Other MAY 2 4 206 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTFON ® No discharge this period?2 Outfall No. Date Sample collected' (mo/dd/yr) 24-hour rainfall amount, IncheS3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall ill Outfall t#2 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." LM ✓ S e,11l1?--i Name (Print name) Elk 4 Title (Print title) X�IL� 05 -2-Z -I(v (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMA, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2417 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results 5-17-16 SAMPLE COLLECTION YEAR _2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly) -August month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow []Water Supply ❑SA [—]Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 � REeEIVED MAY 2 4 2016 ❑ No dischorge this period?z Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids CENTRAL FILES DWR ACT Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 8-6-15 0.25 1.60 6.3 0.369 <0.003 0.134 <5.00 N/A Outfall #2 8-11-15 0.10 52.0 6.o 0.209 <0.003 0.0910 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." IleV_IIL; , Name (Print name) E�T J 4- Title (P int titl V %r �vr�-t US� - Z z - & (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected1 (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: ff you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr, Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results (or of end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." {Signature of Pe Permit Date:il/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall— Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _201S SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other RECEIVE[5LEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 MAY 24iuiQ ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids DWR pH, Standard units ECTtON Copper Lead Zinc Non -Polar o&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks =__> _ 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall 41 9-24-15 0.40 31.0 7.5 0.174 0.005 0.126 6.26 N/A Outfall42 9-24-15 0.40 17.0 6.3 1.59 0.006 0.238 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater/Pollution Prevention Plan." Name (Print name) AA Title (P int title) . (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Nate: if you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) T Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 1 � Semi-annual Stormwater Discharge Monitoring Resort for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Coraoratio COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly'_ October (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA � ` ,D [:]Zero -flow [-]watersupply [:]SAgec, V Other MM 14 Z5$ PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 C WR �CTt4N D ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 10-10-15 0.30 < 1.0 7.5 0.053 <0.003 0.059 <5.00 N/A Outfall ##2 10-10-15 0.30 2.40 7.4 0.266 <0.003 0.072 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." :��/'� ✓'. 5 � ✓YL1-mil Name (Print name) ,[6�s r .; ) X Abu Title (Pri title) os 22- /�, (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results Lor at end of monitoring period in the case of "No Discharge" reports) to. Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) o5'-7,2 � (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on Sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' November (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CE ITRAL- FILE ® 9 period?' No dischar e this eriod. Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 Outfall #2 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 FaCiilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." /1 L15 Name (Print name) F%7J -4- JuS.t� !'1 uYC Title (Print title) 1.4 (Signature) ( Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected'[ (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 {SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 llrute: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION 6. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy a this DMR ,--including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." [Signature of 05-Z7 /�, (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5-17-16 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore~ PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall_ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR W2015 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow [:]waterSupply [:]SA V �] [:]Other R `EC E I " E "PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 MAY 24 ZU16 CENTRAL FILES DWR SECTION ❑ No discharge this period?z Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic 5 Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 12-17-15 0.20 18.3 7.2 0.643 0.004 0.247 <5.00 N/A Outfall #2 12-17-15 0.20 4.80 7.3 0.247 <0.003 0.172 <5.00 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." L1/,, I/e'y-t�3—� Name (Print name) Title (Pri title) / 'w 0��_2Z—l(y (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 su Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMH including all "No Discharge" reports, within 30 days of receipt of the lob results (or at end of monitoring period in the case of "No Discharge" reports] to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date:11/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 AA AL.. W 111:13 0- J-9 ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. May 20, 2016 VIA OVERNIGHT MAIL Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Stonnwater Discharge Monitoring Reports Certificate of Coverage No. NCG030627 To Whom It May Concern: Phone: 1-910-944-3355 Fax: 1-910-944-3418 www.erico.com h -%v4j COPY RECEIVED MAY 2 4 2016 CENTRAL FILES DWR SECTION ERICO International Corporation ("ERICO") recently conducted a corporate compliance review of the above -referenced facility and discovered that although the facility has conducted all of the required monthly stormwater sampling over the last year, the facility inadvertently failed to submit the required DMR to the DWQ as required under Section E:Reporting Requirements of the General permit. We apologize for this oversight. To correct the error, please find enclosed two signed copies of the Discharge Monitoring Reports ("DMRs") for June through December 2015 and for January through April 2016, for the above -referenced facility. In addition, we note that there are exceedenees of the benchmark values contained in the permit. We are in the process of investigating the root cause(s) and expect to be installing additional best management practices and updating our stormwater pollution prevention plan in the near future to address these issues. If you have any questions, please don't hesitate to call me at (910)-944-3355. Enclosures cc: Chris Herron, ERICO Allison Montgomery, Pentair Adam Sowatzka, King & Spalding CADDY® • ERICO® • ERIFLEX' • ERITECN' • LENTON® Semi-annual Stormwater Discharge Monitoring Rem for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12-31-14 CERTIFICATE OF COVERAGE NO. N00030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' December (rBdn- A) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNAJ ❑Zero -flow ❑Water Supply SA �Ay [:]Other�ECEIVEU PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 JAN' O 6 2015 CENTRAL FILES DWR SECTION ❑ No discharge this perrod?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 12-6-14 0.25 26.0 7.2 0.34 0.0049 0.13 1.44 N/A Outfall #2 12-6-14 0.25 15.4 6.9 0.81 0.0029 0.15 0.410 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For- those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO); I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print Z�1751 //Z/ (Signature) vl�(Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX m /L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period:2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ==_> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an on inal and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reeortsi ta: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 4.6/z (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12-12-14 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Monthly( November (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow [:]WaterSupply ❑SA RECEIVED ®Other Unable to obtain sample DEC 16 2014 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, 3 Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum hydrocarbons Total Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 - - - - - - N/A Outfall #2 - - - - - - - - N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print ti ) (Signature) (bate) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L` 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table S, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer___ Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of hrmitlee) L IS (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 10-22-14 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Monthly' September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flaw [:]waterSupply ❑SA 'RECEIVED ❑Other OCT 2 3 1i0 '4 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENT-RAL FILES L)WR SECTION ❑ No discharge this period?' Outfall No. Date Sample r Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmarks ===> - - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 9-13-14 0.40 1.25 6.99 0.48 0.0013 0.14 2.22 N/A Outfall #2 9-13-14 0.40 2.50 6.85 0.18 <0.0010 0.086 2.37 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the 5tormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit ) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected, (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Resort for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Frank Bryant LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' August _ _ (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA RECEI ED []Other OCT 0 3 2014 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, lnches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 8-16-14 0.30 11.2 6.60 0.26 0.0034 0.14 2.13 N/A Outfall #2 8-16-14 0.30 39.0 6.74 2.3 0.0055 0.34 2.71 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit ) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Nofe: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitorina Period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." r (Signature of Per ittee) (D te) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater DischaEge-Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 8-27-14 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Joe Holt LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' July (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVE® ❑Zero -flow ❑Water Supply ❑SA ❑Other SEP 0 2 2014 CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DWQlBOG No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 7-15-14 0.50 25.0 7.38 0.45 0.0069 0.15 1.60 N/A Outfall #2 7-15-14 0.50 20.2 7.60 0.32 0.023 0.13 1.07 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print title (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format_"<XX m L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (5GT-HEM) Total Suspended Solids pH Benchmarks =__> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." L,�, - 44,.�-- )�3/ff/w (Signature of Permittee) (Dat Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE No. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Joe Holt LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis:_ Outfall #1 & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results 7-15-14 SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly) June (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVED y ❑Zero -flow ❑Water Supply ❑SA i �j ❑Other AUG 2 8 2014 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 '), CENTRAL FILES DWQ/BOG ❑ No discharge this period: Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 6-12-14 0.80 34.2 7.11 0.44 0.0051 0.16 1.68 N/A Outfall #2 6-12-14 0.80 16.2 6.45 9.60 0.020 1.0 2.59 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed Lo rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit' ) /4�/ 8 b/ (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format <XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2of3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" resorts, within 30 days of receipt of the lab results !or at end of monitoring period in the case of "No Discharge" reportsl to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." {Signature � / (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/2S/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 7-15-14 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES LABORATORY Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR �2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' May (monthl RECEiv EDISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow ]Water Supply ❑SA --AUG 2 S 2014 Mother —Unable to obtain sample_ CENTRAL TES QWQ/8QG PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ® No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 N/A Outfall #2 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print titl ) AIL 8 (Signature) (Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ®NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results for at end of monitoring period in the case o "No Dischar e" re orts to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Z�z [Signature of erm tee) (Da e) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted iI IC6-5-14 I rL_vc.. v 16- CERTIFICATE OF COVERAGE NO. NCG030627 JUN 11 2014 FACILITY NAME ERICO International Corporation CENTRAL FILES COUNTY Moore DWQIBOG PERSON COLLECTING SAMPLES Joe C. Holt LABORATORY Microbac Lab Cert. # _NCDNR#11 Comments on sample collection or analysis: _Outfall #1b & Outfall #2 samples were taken after a dolomite lime check dam was installed prior to each outfall Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑Jan -June ❑ July -Dec or ® Monthly' April (month) DISCHARGING TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA ❑Zero -flaw ❑Water Supply [:]SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic 5 Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #la 4-14-14 0.50 40.0 7.44 0.80 0.0082 0.27 < 5.0 N/A outfall #lb 4-15-14 0.50 43.0 7.64 0.63 0.011 0.23 <5.0 N/A Outfall #2 4-15-14 0.50 84.2 7.12 4.5 0.0029 0.39 <5.0 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print title) -4, WT A)"'I'4:1 e, 5 4L (Signature) b (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. (Vote: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (5GT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if You report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of 5 1 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. June 5, 2014 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern: Phone:1-910-944-3355 " Fax: 1-910-944-3418 www.erico.com Please find enclosed the Discharge Monitoring Report (DMR) for the month of April 2014,for the ERICO International Corporation (ERICO) facility referenced above. If you have any questions, please don't hesitate to call me at (910)-944-3355. Sincerely, 1 Keith Adams Plant Manager cc: Mykela Marshall, ERICO Amy S. Lucia, ERICO CADDY® • ERICO® • ERIFLEX" • ERITECH® • LENTON® Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE No. NCGi030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES Frank Bryant LABORATORY Microbac Lab Cert. # NCDNR#11 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results 5-9-14 SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' March (month) DISCHARGING TO CLASS []ORW ❑HQW [—]Trout ❑PNA ❑Zero -flow ❑Water Supply []SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 1S mg/L 1 mg/L Outfall #1 3-16-14 0.45 25.0 6.32 6.5 0.003 1.86 < 5.0 N/A Outfall #2 3-16-14 0.45 14.4 7.23 0.93 <0.0010 0.268 <5.0 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring �^ may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General - Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print tit ) rjj.4,1,V h 4 (Signature) bate) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format_, "<XX r"FJL", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit bate: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 "-jk� Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART II SECTION B. • 2 FXCEFDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. + TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO REGIONAL OFFICE CONTACT NAME: Mr. Mike Lawyer Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, !North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and relief, true, accurate, and complete. I am aware that (here are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 ERICO International Corporation 188 Carolina Road Aberdeen, NC 28315 U.S.A. May 9, 2014 Division of Water Quality Attn- DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE- ERICO International Corporation 188 Carolina Rd., Aberdeen, NC 28315 Certificate of Coverage No. NCG030627 To Whom It May Concern- RECEIV ED MAY 15 2014 CENTRAL FILES DWQIBOG Phone:1-910-944-3355 Fax: 1-910-944-3418 www.erico.com Please find enclosed the Discharge Monitoring Report (DMR) for the month of March 2014 for the ERICO International Corporation (ERICO) facility referenced above. If you have any questions, please don't hesitate to call me at (910)-944-3355. Sincerely, w �4� Keith Adams Plant Manager CC: Mykela Marshall, ERICO Amy S. Lucia, ERICO CADDY" • ERICO® • ERIFLEX* • ERITECN' • LENTON' 1, Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _Joe Holt LABORATORY Microbac Lab Cert. f# _NCDNR#11 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results 3-11-14 SAMPLE COLLECTION YEAR �2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly'.__ February--_ (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, 3 Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 2-4-14 0.50 21.2 7.54 0.23 0.0053 0.131 < 5.0 N/A Outfall #2 2-4-14 0.50 60.8 7.30 0.37 0.0028 0.176 <5.0 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 RECEIVED MAR 17 2014 CENTRAL FILES DWQ/BOG SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Pr:1) X Aq (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfail No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DM_R, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of ,-�L ' 14 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 3-11-14 CERTIFICATE OF COVERAGE NO. NCG030627 FACILITY NAME ERICO International Corporation COUNTY Moore PERSON COLLECTING SAMPLES _toe Holt LABORATORY Microbac Lab Cert. # NCDNR#11 Comments an sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2014 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ® Monthly' January (month' DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow [:]waterSupply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ® No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss 8enchmorks 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall #1 N/A Outfall #2 N/A ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 RECEIVED MAR 17 ai4 CENTRAL FILES, DWQ/BOG 5WU-245, last revised 10/25/2012 Page 1 of 3 i Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Keith Adams Name (Print name) Plant Manager Title (Print t e) A,4 3 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfail No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 r Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE QUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an oriainal and one coon of this AMR. includina all "No Discharae" reports, within 30 dovs of receipt of the lab results for at end of monitorina period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27644-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of 3 (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3