HomeMy WebLinkAboutOrchard Tie Substation - Revised DrawingsORCHARD TIE GENERAL INFORMATION PROJECT DESCRIPTION DUKE ENERGY WILL BE GRADING THE PROPOSED ORCHARD TIE RETAIL PROPERTY TO BUILD A 230-100kV SUBSTATION. TO ACCOMPLISH THE PROPOSED GRADING DUKE ENERGY WILL CLEAR AND GRUB A LARGE WOODED AREA, INSTALL SILT FENCING, INSTALL BERMS, SPCC MEASURES, AND TWO WET STORMWATER PONDS. ( OTHER INFORMATION ALL SITE WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND FEDERAL LAWS, REGULATIONS, PERMITS, AND DUKE STANDARD PRACTICES. ALL CONDITIONS OF PERMITTING SHALL BE FOLLOWED AND AND BE CONSIDERED PART OF THE CONTRACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FOLLOWING ALL REQUIREMENTS AS OUTLINED IN THIS PACKAGE. SITE IMPROVEMENT AND GRADING REQUIREMENTS THE CONTRACTOR SHALL MAINTAIN PUBLIC RIGHTS -OF -WAY IN A CLEAN, SAFE, AND USEABLE CONDITION. SPILLS OF SOIL, ROCK, OR OTHER CONSTRUCTION DEBRIS SHALL BE REMOVED FROM THE PUBLIC PROPERTY DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT. CONSTRUCTION SHALL BE STOPPED IF CULTURAL RESOURCES ARE SUSPECTED. IF SIGNS OF AN ARCHAELOGICAL SITE, SUCH AS UNUSUAL AMOUNTS OF STONE, BONE, OR SHELL ARE UNCOVERED DURING CONSTRUCTION ACTIVITIES, WORK SHALL BE HALTED WITHIN 100 FEET OF THE FIND. A QUALIFIED ARCHAEOLOGIST SHALL BE RETAINED FOR AN ON -SITE EVALUATION. CONSTRUCTION SHALL BE STOPPED AND THE LOCAL FIRE DEPARTMENT CONTACTED IMMEDIATELY IF HAZARDOUS MATERIALS, OR WHAT APPEARS TO BE HAZARDOUS MATERIALS ARE UNCOVERED DURING GRADING OPERATIONS. THE AREA CONTAINING THE HAZARDOUS MATERIALS SHALL BE MARKED OFF UNTIL A MEMBER OF THE FIRE DEPARTMENT CONDUCTS AN INVESTIGATION. SCOPE OF WORK INSTALL ALL EROSION CONTROL MEASURES (SILT FENCE AND CONSTRUCTION ENTRANCE) PRIOR TO START OF CONSTRUCTION. CLEAR AND GRUB SUBSTATION CLEARING 27.78 ACRES TRANSMISSION LINE CLEARING 17.34 ACRES TOTAL APPROXIMATELY 45.12 ACRES. THE SUBSTATION WILL FENCE APPROXIMATELY 13.26 ACRES. GRADE AND GRAVEL ACCESS DRIVE FROM ELBOW ROAD. LEGEND PROPERTY LINE — — TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR — 880— — EXISTING TOPO MINOR CONTOUR - - - - - - - EXISTING STREAM • • • • • - EXISTING BARBED WIRE FENCE-x-=---------- CHAINLINK FENCE CATTLE FENCE xxxx— PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) OE DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LODLODLOD El #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET OJM CHECK DAM co_, RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE -RCP _ REINFORCED CONCRETE PIPE __CMP _ CORRUGATED METAL PIPE CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) �)X PROPERTY LINE 1 / ! ;WEST WET POND I RELAY \, , I HOUSES "7 I I GRAVEL I I ACCESS ROADS � o f NEWTON, NC 28658 0 SITE PLAN I SUBSTATION PAD I dEAST WET `• = -'Row LINE —�CATTLE r FENCE �,. SUBSTATION X ENTRANCE 77 ti RIGHT OF WAY \ ACCESS ENTRANCE PROPERTY LINE PARCEL DATA OWNER: DUKE ENERGY CAROLINAS, LLC ATTN:LEAD ENGINEER - WAYNE WANG PO BOX 1007 CHARLOTTE, NORTH CAROLINA 28201 CONTACT RESPONSIBLE FOR MAINTENANCE: NEAL CARY (DUKE) PHONE: (980) 373-0826 CELL: (704) 575-3424 LOCATION: LATITUDE: N 35.5974` LONGITUDE: E 81.2764• PARCEL NO: 332706298776 TOTAL AREA: 134.79f AC PARCEL ZONING: R-40 TOWNSHIP: JACOBS FORK COUNTY: CATAWBA ADDRESS: 2865 ELBOW RD NEWTON, NORTH CAROLINA 28658 30 30 30 30 —30 � _30 _-3D —3D * _ 30 30 avo * ELBOW ROAD / * I *\*\ PROPERTY *\LINE * *\* CATTLE FENCE IX/+max 07- JI II Il� �I I �I I s SCALE: N.T.S. I IY1 I 11 SITE DATA TOTAL PROPOSED SITE AREA: 134.79f AC (DEEDED) TOTAL DISTURBED AREA: 45.12f AC EXISTING IMPERVIOUS AREA: 0.00 AC GRAVEL DRIVE AREA PROPOSED NEW IMPERVIOUS AREA: 2.59f AC GRAVEL AREA WATERSHEDS: SOUTH FORK CATAWBA RIVER TRIBUTARY 1 FIRM MAP NUMBER: 3710362700J FLOOD ZONE: PANEL 3627 PROPOSED % BUILT UPON AREA: 10% DENSITY (HIGH/LOW): HIGH ISSUED FO-R COIVST_h'UCTION FIRST ISSUE BY W.O. 17757514 Mesa Associates, PLL Engineers and Consultants 629 Market Street, Suite 200 Chattanooga, TN 37402-4802 Tel. (423) 424-7300 NC Engr. Cert. No.: P-0193 r--------- I I I I I I I I ORCHARD TIE SUBSTATION ­&l4c I T I I I I I I I I I I I I I I I I I I 0 I I I I I I I I I CONSTRUCTION NOTES EXISTING SITE PLAN _ EXISTING SITE PLAN _ SITE PLAN CLEARING AND GRUBBING PLAN EROSION CONTROL PLAN ---- ---- EROSION CONTROL PLAN ---- ---- EROSION CONTROL PLAN EROSION CONTROL DETAILS EROSION CONTROL DETAILS EROSION CONTROL DETAILS EROSION CONTROL DETAILS LANDSCAPE PLAN EROSION CONTROL DETAILS _______ EAST POND VEGETATION PLAN WEST POND VEGETATION PLAN GRADING PLAN ACCESS ROAD GRADING AND PROFILE ACCESS ROAD GRADING AND PROFILE ACCESS ROAD GRADING DETAILS ROADWAY LINE OF SIGHT PLAN _ TOWER MAINTENANCE ROAD GRADING AND PROFILE VICINITY MAP ------------- ----- I I I I I I I t� y 0 IY �IAI��1V � I I I I I M EN I I I ti _1 I I I —-------------------------------------------J COMPANION DRAWINGS 40788754SDV SH 2 TOWER MAINTENANCE ROAD GRADING 40788754SDV SH 3 AND PROFILE ________________ 40788754SDV SH 4 TOWER MAINTENANCE ROAD GRADING AND PROFILE 40788754SDV SH 5 TOWER MAINTENANCE ROAD GRADING 40788754ERC SH 1 AND PROFILE ________________ 40788754ERC SH 2 TOWER MAINTENANCE ROAD GRADING AND PROFILE 40788754ERC SH 3 S ORM D AINAG PLA 40788754ERC SH 4 STORM DRAINAGE PROFILES 40788754ERC SH 5 STORM DRAINAGE DETAILS 40788754ERC SH 6 STORM DRAINAGE DETAILS 40788754ERC SH 7 OVERALL PRE -CONSTRUCTION 40788754ERC SH 8 DRAINAGE MAP 40788754ERC SH 9 PRE -CONSTRUCTION DRAINAGE MAP 40788754ERC SH 10 PRE -CONSTRUCTION DRAINAGE MAP 40788754ERC SH 11 OVERALL POST -CONSTRUCTION DRAINAGE MAP _______________ 40788754ERC SH 12 POST -CONSTRUCTION DRAINAGE MAP 40788754GRA SH 1 POST -CONSTRUCTION DRAINAGE MAP 40788754GRA SH 2 SOILS MAP _________________. 40788754GRA SH 3 USGS MAP __________________ 40788754GRA SH 4 SPCC PLAN _________________ 40788754GRA SH 5 SPCC DETAILS 40788754GRA SH 6 40788754GRA SH 7 40788754GRA SH 8 40788754GRA SH 9 40788754GRA �HM11040 8854 DR 40788754SDR SH 2 40788754SDR SH 3 40788754SDR SH 4 40788754DRG SH 1 40788754DRG SH 2 40788754DRG SH 3 40788754DRG SH 4 40788754DRG SH 5 40788754DRG SH 6 40788754DRG SH 7 40788754DRG SH 8 40788754SPC SH 1 40788754SPC SH 2 2 CONVERTED SEDIMENT PONDS TO WET PONDS AND UPDATED DRAWING LIST NEW WORK FF9193C1 I JED/MESA I LHH/MESA WED/MESA/WW 11/13/2018 1 INCORPORATED PERMITTING COMMENTS NEW WORK FF9193C1 JED/MESA LHH/MESA WED/MESA/WW 09/10/2018 0 ISSUED FOR PERMITTING NEW WORK FF9193C1 JED/MESA LHH/MESA WED/MESA/WW 08/27/2018 REV DESCRIPTION ISSUE TYPE DPN DFT DES/CHK ENG DATE REVISION HISTORY SEAL: THT� H ITIn"O OR ❑ PRELIMINARY TITLE: COVER SHEET DILL 01�' VlITER11L Lv ,,.•`,�N GAq�'�% COVI IUL 1'II 1L ❑ AS BUILT ZERO 230-100kV SUBSTATION OQ`••FESS/p • I;\lD :V.fl` NOT DL Contract: ' QQ' I,OANF,D, RFPROUT Fb SEAL _ OR COPIF,D, FIT\R LOCATION: ORCHARD TIE 036553 — 1NHOLLI" OR I V' 1'4RT. Company: :, ;Q`; OR :U9UG 1'L11LIC L\ =,1��•..........01NEEQ•'�"IF ' 9��'Y �l1A.VN\ VIrITIIOUT phone: ���E CITY: NEWTON COUNTY: CATAWBA STATE: NC �j�G ��` THE it RITTF, A' SHEET SIZE: REGION: STATION NUMBER: DRAWING NUMBER: REV: 01�' UL E LVERGY Date: ENERGY® ARCH D NC -SC 2753 40788754SDV 2 CORPOR_41'I0V'. SHEET 1 OF 5 FILENAME: 40788754SD V-R2. O W6 SITE GENERAL NOTES: 1. VERTICAL DATUM ESTABLISHED BY LIDAR. A 2' CONTOUR INTERVAL IS SHOWN. INSPECTIONS. TESTS. AND REPORTS EROSION CONTROL NOTES: 2. PROPERTY DOES NOT LIE WITHIN A FLOOD HAZARD AREA AS DETERMINED BY FEMA MAP NUMBER 371O3627000J, EFFECTIVE SEPTEMBER 9, 2007. 3. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT IMMEDIATELY. 4. ALL WATERS OF THE STATE (WOS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SEDIMENT TUBE IS TO BE INSTALLED IN ALL AREAS WHERE A 30-FOOT AND/OR 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WOS. A MINIMUM 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS. 5. A COPY OF THE SWPPP, INSPECTIONS RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBY LOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRUCTION ACTIVITIES TO THE DATE THAT FINAL STABILIZATION IS REACHED. 6. IF EXISTING BMP'S NEED TO BE MODIFIED OR IF ADDITIONAL BMP'S ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THIS PERMIT AND/OR NC'S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BE DOCUMENTED IN THE SWPPP AND ALTERNATIVE STORM WATER QUALITY CONTROL MEASURES MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE. 7. A PRE -CONSTRUCTION CONFERENCE MUST BE HELD FOR THE CONSTRUCTION SITE WITH AN APPROVED ON -SITE SWPPP PRIOR TO THE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. 8. IF NECESSARY, SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE. 9. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN DAYS AFTER WORK HAS CEASED EXCEPT AS STATED BELOW. * WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE. * WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH -DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. 10. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK OR AFTER A RAIN EVENT PRODUCING I" OR GREATER PRECIPITATION. IF PERIODIC INSPECTION OR OTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY OR INCORRECTLY INSTALLED THE PERMITTEE MUST ADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION. 11. PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING,THE WATER SHOULD BE FILTERED TO REMOVE SEDIMENT BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE. 12. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILZED. 13. TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT -LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. 14. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES. 15. INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1 V OR GREATER) WHERE LAND -DISTURBING ACTIVITIES HAVE PERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR A PERIOD OF 7 CALENDAR DAYS. 16. MINIMIZE SOIL COMPACTION AND, UNLESS INFEASIBLE, PRESERVE TOPSOIL. TOPSOIL PRESERVATION SHOULD BE ON- SITE WITH PROPER SEDIMENT/EROSION CONTROLS. RECOMMENDED STOCK PILING LOCATION WITH DETAILS ARE SHOWN IN DESIGN DOCUMENTS. 17. PREVENT THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE; 18. PREVENT THE DISCHARGE OF POLLUTANTS FROM DE -WATERING OF TRENCHES AND EXCAVATED AREAS. THESE DISCHARGES ARE TO BE ROUTED THROUGH APPROPRIATE BMP'S (SEDIMENT BASIN, FILTER BAG, ETC.). 19. THE FOLLOWING DISCHARGES FROM THE SITE ARE PROHIBITED: WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL (SUCH AS A CONCRETE WASHOUT PIT); WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS; FUELS, OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE; SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING. 20. AFTER CONSTRUCTION ACTIVITIES BEGIN, SWPPP INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDAR WEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL AREAS OF THE CONSTRUCTION SITE. ALL REQUIRED INSPECTIONS AND TEST SHALL BE PERFORMED BY A QUALIFIED AND APPROVED TESTING AND INSPECTION AGENCY. COPIES OF ALL INSPECTION AND TEST REPORTS SHALL BE FURNISHED TO THE DUKE SUBSTATION ENGINEER. ONE SET OF INSPECTION REPORTS SHALL BE KEPT ON SITE. PROPOSED SCHEDULE OF EVENTS AND CONSTRUCTION SEQUENCE 1. OBTAIN EROSION CONTROL PLAN APPROVAL AND OTHER APPLICABLE PERMITS. 2. NOTIFY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY- MOORESVILLE REGIONAL OFFICE (704-663-1699) AT LEAST 48 HOURS PRIOR TO BEGINNING SITE DISTURBANCE ACTIVITIES. 3. MARK AND IDENTIFY CLEARING LIMITS, STREAM BUFFER LIMITS THAT MUST BE MAINTAINED AND DELINEATE WETLANDS TO BE PROTECTED. 4. INSTALL ALL EROSION AND SEDIMENT CONTROLS PRIOR TO BEGINNING THE PROJECT ACTIVITIES IN ACCORDANCE WITH THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL (LATEST EDITION). a.TEMPORARY SEDIMENT BARRIERS (I.E., SEDIMENT FENCING) SHALL BE INSTALLED DOWN SLOPE OF DISTURBED AREAS AND ALONG THE PERIMETER OF THE TOPSOIL STOCKPILE AREA. b.LAND-DISTURBING ACTIVITY AT THE PROJECT SITE SHALL BEGIN WITH THE INSTALLATION OF THE CONSTRUCTION ENTRANCE/EXIT(S) AS NECESSARY. c. EROSION AND SEDIMENT CONTROLS WILL BE MAINTAINED ON A DAILY BASIS THROUGHOUT THE CONSTRUCTION PROJECT. d.INSPECT ALL EROSION CONTROL DEVICES AT WEEKLY INTERVALS AND AFTER EVERY RAINFALL EXCEEDING �/" TO VERIFY THAT THEY ARE FUNCTIONING PROPERLY. 5. CLEARING WORK NECESSARY FOR EROSION CONTROL MEASURES AND CLEAN WATER DIVERSIONS. CLEARING ACTIVITIES SUCH AS TREE CLEARING FOR REMAINDER OF SITE. THERE WILL BE TWO TYPES OF CLEARING. CLEARING FOR THE SUBSTATION GRADING AND CLEARING FOR THE TRANSMISSION LINE INSTALLATION. CLEARING FOR THE SUBSTATION GRADING WILL INCLUDE TREE REMOVAL, GRUBBING, AND TOPSOIL REMOVAL. CLEARING FOR THE TRANSMISSION LINES WILL CONSIST OF TREE CUTTING, BUT NO GRUBBING OR TOPSOIL REMOVAL. CLEARING WITHOUT GRUBBING MAY OCCUR UNTIL THE NCDEQ STORMWATER PERMIT IS OBTAINED. 6. INSTALLATION OF TEMPORARY DIVERSIONS, SEDIMENT TRAP #1, SKIMMER BASINS #1 & #2, AND THE EAST AND WEST SEDIMENT BASINS. THIS INCLUDES OUTLET STRUCTURES AND ENERGY DISSIPATER DEVICES. 7. SEDIMENT BASINS SHOULD BE STABILIZED IMMEDIATELY AFTER INSTALLATION INCLUDING THE SIDE EMBANKMENTS. TEMPORARY DIVERSION CHANNELS THAT WILL STAY IN PLACE LONGER THAN 30 WORKING DAYS SHOULD BE SEEDED AND MULCHED AS SOON AS THEY ARE CONSTRUCTED TO PRESERVE DIKE HEIGHT AND REDUCE MAINTENANCE. 8. CLEAR AND GRUB REMAINING AREAS OF THE SITE. 9. SUBSTATION EARTHWORK AND ACCESS ROADS, INCLUDING EXCAVATION, FILL, AND GRADING. GRADING SHOULD BE PERFORMED IN A WAY THAT MAINTAINS DRAINAGE OF DISTURBED AREAS TO THE SEDIMENT BASINS. 10. UPON COMPLETION OF CLEARING AND GRADING, STABILIZE ALL SURFACES FOR PERMANENT VEGETATION, INCLUDING SLOPES AND DISTURBED AREAS WITHIN 7 TO 14 CALENDAR DAYS AS NOTED ON THE PLANS. 11. ONCE SUBGRADE FOR THE STATION YARD IS ACHIEVED THE INSTALLATION OF YARD DRAINAGE FEATURES (CATCH BASINS, DRAIN LINES, AND OIL/WATER SEPARATORS) WILL BE INSTALLED ALONG WITH A THIN LAYER (APPROXIMATELY 2 INCHES THICK) OF STONE TO STABILIZE THE YARD AREA. 12. PRIOR TO COMPLETION OF INSTALLATION OF STORM DRAINAGE SYSTEM ON THE EAST SIDE OF THE YARD, THE DRAINAGE CHANNEL CONVEYING STORMWATER TO THE EAST BASIN SHALL BE CONSTRUCTED AND STABILIZED WITH RIPRAP. 13. AFTER THE YARD DRAINAGE FEATURES ARE FINISHED, INLET PROTECTION DEVICES SHOULD BE INSTALLED. 14. HOLD UNTIL NCDEQ STORMWATER PERMIT IS OBTAINED. 15. INSTALL SUBSTATION ACCESS ROADS WITH CRUSHER RUN TYPE GRAVEL WITH ALL REQUIRED CULVERTS WITH INLET/OUTLET PROTECTION. 16. ACCESS ROADS ON GRADES OF 20% OR GREATER SHALL BE SURFACED WITH A 6" LAYER OF GRAVEL OR AGGREGATE BASE COURSE FOR STABILIZATION. ACCESS ROADS SHOULD BE STABILIZED DAILY. 17. UPON COMPLETION OF GRADING, STABILIZE ALL SURFACES FOR PERMANENT VEGETATION, INCLUDING ALL ROAD BEDS, SLOPES, AND DISTURBED AREAS WITHIN 7 TO 14 CALENDAR DAYS AS NOTED ON N 18. A ER P M N T ST BIL ZA 10 0 THE UBSTATIO AR H S E OM L ED, R M VE SEDIMENT BASIN STRUCTURES, RE -GRADE SEDIMENT BASINS TO WET POND ELEVATIONS, INSTALL _WES PDNQ DRAINAGE SJRUCTl1RES AND PIPING- _ _ _ _ _ _ _ _ _ _ _ _ _ 20. INSTALL DRIVEWAY APRON. 21. MAINTAIN ALL EROSION CONTROL DEVICES THROUGHOUT THE DURATION OF LAND DISTURBING ACTIVITIES. 22. CONTRACTOR TO REMOVE ALL EROSION CONTROL MEASURES AFTER SITE IS STABILIZED AND SUBMIT NOTE TO NCDEQ. INSPECTION AND FINAL APPROVAL BY A REPRESENTATIVE OF THE LAND QUALITY SECTION REQUIRED PRIOR TO REMOVAL OF SEDIMENT AND EROSION CONTROL MEASURES. 23. REMOVE SEDIMENT AND EROSION CONTROL MEASURES AFTER SITE STABILIZATION AT THE DIRECTION OF THE OWNER'S DULY AUTHORIZED AGENT. CLEARING AND GRUBBING NOTES: 1. EXISTING UNDERGROUND AND OVERHEAD UTILITIES, PAVEMENT, STRUCTURES AND OTHER FEATURES DEPICTED ON THE DRAWINGS ARE SHOWN IN THE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY, IN THE FIELD, THE EXACT LOCATION OF THESE OR ANY OTHER EXISTING FEATURES IN OR ADJACENT TO THE PROJECT LIMITS. 2. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING CONSTRUCTION PHASES OF THIS PROJECT. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ANY DAMAGES TO THE ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASES OF THIS PROJECT. 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN ACCORDANCE WITH ALL APPLICABLE OSHA STANDARDS. GRADING NOTES: 1. CONTOURS SHOWN ARE TO FINISH GRADE. 2. ALL AREAS TO BE DISTURBED BY LAND GRADING SHALL BE CLEARED AND GRUBBED TO REMOVE VEGETATION, ROOTS AND OTHER DEBRIS. CONTRACTOR SHALL AVOID DISTURBING NATURAL DRAINAGE COURSES UNLESS SHOWN ON THE GRADING PLAN AND PROPER EROSION CONTROL MEASURES ARE INSTALLED. TOP SOIL INCLUDING GRASS SHALL BE REMOVED IN THE AREA WHICH WILL BE GRADED. 3. CONTRACTOR SHALL REMOVE AND STOCKPILE TOPSOIL FROM ALL AREAS THAT WILL BE DISTURBED BY EXCAVATION, FILLING, OR COMPACTION. STOCKPILE TOPSOIL SO THAT NATURAL DRAINAGE IS NOT DISTURBED AND AVOID STOCKPILING ON STEEP SLOPES. SIDE SLOPES OF STOCKPILE SHOULD NOT EXCEED 2H:1 V. ONSITE STOCKPILE LOCATION SHOWN ON DESIGN DOCUMENTS. PROPER EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED 4. DISTRIBUTE STOCKPILED TOPSOIL OVER DISTURBED AREAS TO A MINIMUM COMPACTED DEPTH OF 4". TOPSOIL SHALL BE UNIFORM IN DEPTH AND FREE OF ROCKS AND DEBRIS. 5. SEEDING AND MULCHING SHALL BE PERFORMED BY THE CONTRACTOR. ALL DISTURBED AREAS EXCLUDING GRAVELED, PAVED AND RIP -RAP AREAS, SHALL BE SEEDED, FERTILIZED AND MULCHED. 6. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH MULCH, VEGETATION, CRUSHED STONE, RIP -RAP OR OTHER MEASURES AS SOON AS WORK IS COMPLETED, OR IF WORK IS INTERRUPTED FOR 14 OR MORE WORKING DAYS. 7. ANY OFF -SITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. ESTABLISHING VEGETATION GENERAL REQUIREMENTS: THE WORK INCLUDES SEEDBED PREPARATION, LIMING, FERTILIZING, SEEDING, AND MULCHING DISTURBED AREAS. MATERIALS: A. LIME IS NOT REQUIRED FOR TEMPORARY SEEDING UNLESS A SOIL TEST SHOWS THAT THE SOIL PH IS BELOW 5.0. IT MAY BE DESIRABLE TO APPLY LIME DURING THE TEMPORARY SEEDING OPERATION TO BENEFIT THE LONG-TERM PERMANENT SEEDING. APPLY A MINIMUM OF 1.5 TONS OF LIME/ACRE (70 LBS./1000 FT 2) WHEN USED. B. APPLY A MINIMUM OF 500 POUNDS PER ACRE OF 10-10-10 FERTILIZER (11.5 POUNDS PER 1000 SQUARE FEET) OR EQUIVALENT DURING TEMPORARY SEEDING UNLESS A SOIL TEST INDICATES A DIFFERENT REQUIREMENT. INCORPORATE FERTILIZER AND LIME (IF USED) INTO THE TOP 4-6 INCHES OF THE SOIL BY DISKING OR OTHER MEANS WHERE CONDITIONS ALLOW. C. SEED SELECTION IS BASED ON GEOGRAPHICAL LOCATION, SOIL TYPE AND THE SEASON OF THE YEAR IN WHICH THE PLANTING IS TO BE DONE. IF A FAST GROWING CROP TO NURSE THE PERMANENT SPECIE OR SPECIES IS REQUIRED, THEN USE THE MIX RATE. FAILURE TO CAREFULLY FOLLOW AGRONOMIC RECOMMENDATIONS RESULTS IN AN INADEQUATE STAND OF TEMPORARY VEGETATION THAT PROVIDES LITTLE OR NO EROSION CONTROL. D. USE MULCH WITH TEMPORARY SEED APPLICATIONS TO RETAIN SOIL MOISTURE AND REDUCE EROSION DURING THE ESTABLISHMENT OF VEGETATION. TYPICAL MULCH APPLICATIONS INCLUDE STRAW, WOOD FIBER, HYDROMULCHES, BFM AND FGM. USE HYDROMULCHES WITH A MINIMUM BLEND OF 70% WOOD FIBERS. E. MULCH COMPRISED OF WOODCHIPS SHALL HAVE NITROGEN FERTILIZER ADDED TO PROVENT NITROGEN DEPLETION OF THE SOIL. PREPARATION OF SEEDBED: LOOSEN THE SOIL SURFACE BEFORE BROADCASTING THE SEED. APPLY SEED EVENLY BY THE MOST CONVENIENT METHOD AVAILABLE FOR THE TYPE OF SEED USED AND THE LOCATION OF THE TEMPORARY SEEDING. TYPICAL APPLICATION METHODS INCLUDE BUT ARE NOT LIMITED TO CYCLONE SEEDERS, ROTARY SPREADERS, DROP SPREADERS, BROADCAST SPREADERS, HAND SPREADERS, CULTIPACKER SEEDER, AND HYDRO -SEEDERS. COVER APPLIED SEED BY RAKING OR DRAGGING A CHAIN, AND THEN LIGHTLY FIRM THE AREA WITH A ROLLER OR CULTIPACKER. SEEDING: TEMPORARY STABILIZATION IS REQUIRED WITHIN 14 DAYS AFTER CONSTRUCTION ACTIVITY IS COMPLETE UNLESS CONSTRUCTION ACTIVITY IS GOING TO RESUME WITHIN 21 DAYS. COVER SEEDED AREAS WITH AN APPROPRIATE MULCH TO PROVIDE PROTECTION FROM THE WEATHER. WHEN THE TEMPORARY VEGETATION DOES NOT GROW QUICKLY OR THICK ENOUGH TO PREVENT EROSION, RE -SEED AS SOON AS POSSIBLE. KEEP SEEDED AREAS ADEQUATELY MOIST. IRRIGATE THE SEEDED AREA IF NORMAL RAINFALL IS NOT ADEQUATE FOR THE GERMINATION AND GROWTH OF SEEDLINGS. WATER SEEDED AREAS AT CONTROLLED RATES THAT ARE LESS THAN THE RATE AT WHICH THE SOIL CAN ABSORB WATER TO PREVENT RUNOFF. RUNOFF OF IRRIGATION WATER WASTES WATER AND CAN CAUSE EROSION. MULCHING: USE MULCH WITH TEMPORARY SEED APPLICATIONS TO RETAIN SOIL MOISTURE AND REDUCE EROSION DURING THE ESTABLISHMENT OF VEGETATION. TYPICAL MULCH APPLICATIONS INCLUDE STRAW, WOOD FIBER, HYDROMULCHES, BFM AND FGM. USE HYDROMULCHES WITH A MINIMUM BLEND OF 70% WOOD FIBERS. THE MOST COMMONLY ACCEPTED MULCH USED IN CONJUNCTION WITH TEMPORARY SEEDING IS SMALL GRAIN STRAW. THIS STRAW SHOULD BE DRY AND FREE FROM MOLD DAMAGE AND NOXIOUS WEEDS. THE STRAW MAY NEED TO BE ANCHORED WITH NETTING OR EMULSIONS TO PREVENT IT FROM BEING BLOWN OR WASHED AWAY APPLY THE STRAW MULCH BY HAND OR MACHINE AT THE RATE 1.5-2 TONS PER ACRE (90 POUNDS PER 1000 SQUARE FEET). FREQUENT INSPECTIONS ARE NECESSARY TO CHECK THAT CONDITIONS FOR GROWTH ARE GOOD. SILT FENCE MAINTENANCE 1. INSPECT FENCE AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. 2. IF FABRIC IS TORN OR INEFFECTIVE IN ANY WAY, REPLACE FABRIC PROMPTLY 3. IF A POST HAS COLLAPSED, REPLACE IMMEDIATELY. 4. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE FOR NEXT RAINFALL. 5. REMOVE FENCE ONLY AFTER GRADED AREAS HAVE BEEN EFFECTIVELY STABILIZED. RESEEDING: RE -SEED AREAS WHERE SEEDING DOES NOT GROW QUICKLY, THICK ENOUGH, OR ADEQUATELY TO PREVENT EROSION. BASE SEED SELECTION SHOULD ON THE REQUIREMENTS OF LOCAL SPECIFICATIONS IaEh-iaxi19N11WTI I1DIE iI_11►I121►I_l►to] 21, INSPECT EVERY 7 CALENDAR DAYS AND WITHIN 24-HOURS AFTER EACH RAINFALL EVENT THAT PRODUCES 1/2-INCHES OR MORE OF PRECIPITATION. COVER SEED WITH MULCH TO PROVIDE PROTECTION. FREQUENT INSPECTIONS ARE NECESSARY TO CHECK THAT CONDITIONS FOR GROWTH ARE GOOD. SUPPLY TEMPORARY SEEDING WITH ADEQUATE MOISTURE. SUPPLY WATER AS NEEDED, ESPECIALLY IN ABNORMALLY HOT OR DRY WEATHER OR ON ADVERSE SITES. CONTROL WATER APPLICATION RATES TO PREVENT RUNOFF. BASE SEED SELECTION ON LOCAL SPECIFICATIONS. RE -SEED AREAS WHERE THE PLANTS DO NOT GROW QUICK ENOUGH, THICK ENOUGH, OR ADEQUATELY ENOUGH TO PREVENT EROSION SHOULD BE RE -SEEDED. APPROXIMATE EROSION CONTROL MATERIAL QUANTITIES ARE AS FOLLOWS: *SILT FENCE: 16,200 LIN. FT. ROCK CHECK DAMS (CLASS B RIP RAP): 20 TONS *SEE 4O788754ERC SHEET 5 FOR SILT FENCE REQUIREMENTS AND DETAILS. NOTE: QUANTITIES SHOWN ARE APPROXIMATE AND FOR THE AID OF THE CONTRACTOR. CONTRACTOR SHALL VERIFY ACTUAL QUANTITIES REQUIRED. ALL REQUIRED EROSION CONTROL MATERIALS SHALL BE SUPPLIED BY THE CONSTRUCTION CONTRACTOR. COMPANION DRAWINGS: 4O788754SDV SH 1, 40788754SDV SH 3, 4O788754SDV SH 4, & 40788754SDV SH 5 FIRST ISSUE BY W.O. 17757514 ISSU-ED FOR C01\1STRUCTION FILENAME: 40788754SD V-R2. D WG -WET POND MAINTENANCE \ \ FASFMFNT \ \ SID SETBACK 4N E.50_0, I I 1 \ —ago \ m 30 EXISTING 24" CMP 20.0' CLEARED / SITE PLAN FENCE ACCESS - SCALE: 1 " = 100' COMPANION DRAWINGS: 40788754SDV SH 1, 40788754SDV SH 2, 40788754SDV SH 3, & 40788754SDV SH 4 FIRST ISSUE BY W.O. 17757514 I I I I I ORCHARD TIE ' SUBSTATION I I I I I I I I I I i I I � � lqc��� � MAIDEN RD b I I I I M EN I I I I L---------------------------------------------------------------- LOCATION MAP NOT TO SCALE LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR - 880- - EXISTING TOPO MINOR CONTOUR - - - - - - - EXISTING STREAM • • • • • - EXISTING BARBED WIRE FENCEX- CHAINLINK FENCE CATTLE FENCE x x x x— PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) —OE DISTRIBUTION LINE RIGHT OF WAY - LIMITS OF DISTURBANCE LODLOD p #4 REBAR(S) e #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM � RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE __RCP _ REINFORCED CONCRETE PIPE __CMP _ CORRUGATED METAL PIPE CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUED FOR C01\1STRUCTION 11 11 1 11 11 - 11 N W FILENAME: 40788754SD V-R2. O WG \\ ( � SEDIMENT TUBES /i SEE 40788754ERC, DETAIL SHEET 6, N. 680850.12 E. 1323978.46 ///O<\,_,/ N. 680758.02 / ROCK DITCH CHECK E. 1322747.16 SEE TYPICAL DETAIL J 3 40788754SDR SH 4 TEMPORARY SEDIMENT \ 1 \ 1 I 1 \\ I ` \ �\ \ ( / / J / �\ TRAP #1 SEE 40788754ERC, SHEET 8, DETAIL 12 MINIMUM 3 BAFFLES t \ \ � \ 'oo, \ \\ \ \ I / / /'- � � � \ \ DIVIDING BASIN INTO 3 N. 680666.26 JEQUAL ZONES / SILT FENCE / E. 1323709.61 �18.00' j i ��—��—o`er`°° 24.50 l // / l 1SF ( �� / r / / r // nj ► l / I / \ - v / �n LOD- =/ SF NSF ue � sF = r ` / —$so / / rrl I ram/�S—�DSFSIF �F—s—J� O O / I / I �./ �/ //// / / / / / / / / // /`� / 7DS— S� D��DSi\ �' _ / �S/TD✓/ \r \ \ J r— / / //—i� / / �/ SILY FEN�E / / / / / / / / r / \ / t / / % 1� —, .� \ �/ SDS� SDI / / / / / / —w— / SEE MATTING SLOPE t PROTECTION, / o l l l / / / / J l N. 680396.09 // / ( / / / / - - ^ TEMPORARY DIVERSION 40788754ERC, DETAIL 3 / r ) E. 1323751.21 SHEET 5 _ r ^ J / _ / SWALE, SEE 40788754ERC , ! / ( / / - /\III I I / / / / - 1 \ SHEET 7 DETAIL 10 ( / // / / � // � SILT FENCE \ ° \ / / // // /SHEET 5, DETAIL 1 WEST SEDIMENT BASIN �oSEE BAFFLE SHEET 6, DETAIL N 680246.62 VA MI_NIMUM 3�BAFFLESA\ E/ 1323862.53 Al 1III/ / EMERG/EiNCDIVIDING BASIN INTO 4�\ o vlASPILLWAYEQUAL ZONES / / Q 0 J N. 680241.18 /�" \\ \�( \\\\ \ \ \ \\ \ \ \ \ \ \ \ \ \ - - \ ) I) 1 \ 1 \ \ \ ✓ \� \ \ \ / / 1 I ( / I ) \ \ �- I ((S �i \� (� / t / l / E. 1323968.00 oSEDIMENT TUBES, / SILT FENCE SHOULD DOUBLE ROW, ) l \ v A \ \ \ \ \ \ I( I ( NOT BE LOCATED SEE 40788754ERC, i ( \ , • 1 V v A \ \ \ - / v �, I I ( ( ) )1 v C V ( / / a3a -i Vim\ t0ENCY A � DOWNSTREAM OF \ SHEET 6, DETAIL 7 OUTFACE STRUCTU RE MERGE SPILLWAY 4 s wz- N. 680215.27 E. 1324009.68 /\ �1----7511 SILT FENCE \ %\� 1 ��\\ \ so �\ \ 3 1p ro \ \\ \ \ SEE MATTING SLOPE PROTECTION SEE / 1 SEE 40788754ERC, \�,\� o \ \�\ 9.Op� � \ I \\ \ , ` I I I I I ORCHARD TIE I SUBSTATION I I I I I I I I I i I I I I I I I I I I I I I I I I I L------------------ ------ 20.00� NOTE: 1. SILT FENCE BELOW FILL SLOPES SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM THE TOE OF SLOPE. 2. SILT FENCE ROCK OUTLETS SHALL BE LOCATED BY CONTRACTOR AT LOW POINTS ALONG SILT FENCE, SEE DETAIL ON 40788754ERC, SHEET 5. 3. STABILIZE SEDIMENT BASINS, SKIMMER BASINS, AND SEDIMENT TRAPS (INCLUDING BASIN WALLS) IMMEDIATELY AFTER INSTALLATIONS. \ \\ SHEET 5, DETAIL 1 \\\\\ 1 \\\ �\ �\ 1 ( I \ \ 40788754ERC SHEET 5 / \ l ` �` �) / / ) o� I EAST SEDIMENT BASIN SEE BAFFLE DETAIL 4 SHT 6 ( ( \ \\ \,DETAIL 3 �/ ( \) IAA��\\ TEMPORARY SKIMMER �A � \ V v - - - / _ / — — I I \ Vvv 1 v Vv I , v v v v �. - BASIN #2 v \ v / �������1������� „- � I � 1 1 I ( \ \ \ \ V A �/ S � - 1 I ��//(_� \ - \ \ \ \\\ /fllflflf llllllllL1 I - \ \ SEE 40788754ERC, � \\ ,\ /-` - \� \ \ / MINIMUM 3 BAFFLES SHEET 8, DETAIL 11 v VvA �.v�\ v _ ( %,� \ ) \ \ r \ J I) ) / \ \ - _ \ _ ( \ \ \ \ DIVIDING BASIN INTO 4 EQUAL ZONES 55 1 / swum .00 / _ TEMPORARY DIVERSION SWALE, SEE 40788754ERC- \ \ \ 1 \ \ I SHEET 7, DETAIL 10 \ / ) I 1N. 679871.82 _- � \ \ -' \ \ \ \ \ \ \ - - - - � -" - / ( \ / \ � 1 / / / •I / / I I I I I I Iv 'y E. 1324006.50 v 125'� / / TDS- TD TDS- TDS T 7D tH T_- I T TDS- TDS 7 TDS T SP L rl SILT FENCE o ROCK DITCH CHECK 4 SEE 40788754ERC, ( L _ J-A -FL SFs S��m SEE TYPICAL DETAIL `- T l/ SHEET 5, DET IL 1 TEMPORARY SKIIMMER �� ( 3 40788754SDR SH 4 BASIN SEE 40788754ERC,ti / / / / / --( ( I I \ \Ir -1 I N. 679655.71 v _,,,,,,,� � v \ \I \\ \ � � SHEET 8, DETAIL 11 / (s � � I I � \ I E E.1323833.80I�/ � \\��/ / � / / 1 \ I / E / I // <\ ( J / " / \ / \ 323 9 N 679588 09 FENCE SEE 40788754ERC, 6 ) � SHEET 5, DETAIL 1 \ l \ \ � \l/l/l/l/l/l/l/l/l/l/l/0/IOOpO/l/lll \ I I y � N. 679575.197 � \ EIT . 1323740.46 / 1 \\ L \ \ ( CDrA C / s / V Afin / ,,,,,,,,,,,,, of, v \s _21 - - ROCK DITCH CHECK SEE TYPICAL DETAIL 3 40788754SDR SH 4 \ N // SILT FENCE FRONT SHEET 5, DETAIL 1 LINE 5p p,\\ \�\ I N. 679210.88 � � ��- — / \ � \l \ \ a\ • � _ Na�679116.82 E. 1322819.48 / _ -I I \• 1 E. 1323448.14 - N. 679026.54 SEfE- Cj\ LANE 5 p - \ �I\ \ \ E. 1323982.59 CONSTRUCTION \ I I \ r ` ✓ - / 1 - _ _ 2 ENTRANCE/EXIT 1 (SEE 40788754GRA, I • _ i� \ �l DETAIL 3, SH 4 I I / R�v N. 6791125.91 OC MPPA ON DRAWING- P0788754ER H 0788 4ERC E. 1323391.69 ELBOW ROAD SH 3, 40788754ERC SH 4, SEAL: 40788754ERC SH 5, 40788754ERC, SH 6, 40788754ERC, SH 7, "Is,,,,,ff" 131, 40788754ERC, SH 8, & ,�'10I CAgo'%� 40788754ERC, SH 9 0.•FEss/p•�� EROSION CONTROL PLAN (PHASE 2) FIRST ISSUE BY W.O. 17757514 ; ;..4 110 SCALE: 1 = 100 N A o c A c c i + o c p I I d U 0 L 0 CA TION MAP NOT TO SCALE LEGEND PROPERTY LINE - - TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR - —380- - EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM • • • • • - EXISTING BARBED WIRE FENCE X X X X X- CHAINLINK FENCE CATTLE FENCE x x x x- PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) —OE DISTRIBUTION LINE RIGHT OF WAY - - LIMITS OF DISTURBANCE LODLODLOD p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) A #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM co-3 RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE -RCP = REINFORCED CONCRETE PIPE _-CMP _ CORRUGATED METAL PIPE RO ROCK OUTLET ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUE_D FOR C01\1STRUCTION 11 11 1 11 11 - 11 N W FILENAME: 40788754ERC-R2 5H 2.0WG i �\� \� ��\Z` // (l/� // i % — \ i ORCHARD TIE c� SUBSTATION / -- 1 _� � SEDIMENT TUBES _SEE 40788754ERC,� O/i � ( II SHEET 6 DETAIL N. 680850.12 I VPU/ E. 1323978.46 0*_ z — _ N. 680758.02 / ROCK DITCH CHECK \' 1I I I I I 1 1 I \ II l \ E. 1322747.16 -\ — \ ,�SEE TYPICAL DETAIL \C \\ \ I -- 3 40788754SDR SH 4 \\\� \ r �- V \ TEMPORARY SEDIMENT --i— _ TRAP 1 I � \ I I \ ` \ / / — f-,�—'` / # I\\\i\ 1\\\ \\ \ \ \ \ \ 1 I — — — \ \ �\ // �\ //i — — — S I 1 SEE MATTING SLOPE �✓ 1 �_/ — {� — \ 1 / SEE 40788754ERC, I I\,\I \\\\ \� / / — \� // / / I I / PROTECTION, 40788754ERC, \ I / SHEET 8, DETAIL 12 \ \ \ ,, ) S l l / \ \\\ \ 1/ — — — i' / / / ( SHEET 5, DETAIL 3 - i-� — "� / l 1 I \� ( I %' \ r -- \ \\ l �� �^ _ Jam/ / I I / —\\ \ —��--f — I\ / 1 ///� N. 680666.26 e�\�� E. 1323709.61 Y / // / i )\1 j I l ) �. \rJ%\�� —\ SILT FENCE / / ) — �` �-.— Loo— �o I 1 SF`� SF SF SF SF F \ i/ / /UO _ _ SILb FEN E4 /y///�/ �/ i p� —--------- ------ 0xxn LOCATION MAP °' oo NOTTO SCALEUi SEE MATTING 'SLOPEio32.00' m PROTECTION, / /N680377.40 FOREBAY E.. NOTES:40788754ERC, SHEET 5, 1323757.70 L DETAI3 / X s I / / / � ,- / i" //"SILT FENCE �/ /SHEET 5 DETAIL 1 / / I 1. ALL AREAS NOT PAVED OR COVERED WITH STONE SHALL BE STABILIZED WITH PERMANENT CATCH BASIN INLET J i / / x / SEEDING. ROADS SHOWN FOR ACCESS TO TRANSMISSION LINE TOWERS SHOULD ALSO BE SEEDED. PROTECTION SEE 2. AFTER ALL SEDIMENT -PRODUCING ACTIVITIES HAVE BEEN PERMANENTLY STABILIZED REMOVE �% I 40788754ERC, SHEET 7 I / // / ,4s" �/ / /�� /� / I i APRON \ x V I DETAIL 9 / / // / // / / �j I / TEMPORARY SKIMMER BASINS #1, #2, AS WELL AS SEDIMENT TRAP #1 AND ALL THE UNSTABLE \ TYPICAL ALL CATCHBASINS / i / i / ' A/ SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY. I \ / / � / / 1 \ / // N. 680246.62 // //// 3. AREA TO BE STABILIZED WITH VEGETATION IS 29.3 ACRES. AREAS NOT STABILIZED WITH STONE \ / I (,� ( I I I \ \\ \ \ \ \ \� \ \ \ \ ` \ \ \ I I / / E. 1323862 3 / / / FOR YARD, ACCESS ROADS AND RIP -RAP STABILIZATION SHALL BE STABILIZED WITH I I I �..�� \ IEMERGENCY VEG AT WEST WET POND A \ �I / / WEST ,I�\ \I\I\\\\\� \\ \ \ \ \ `� SPILLWAY 4 DRAINING TOCONVERT STHENSDEDIMEN T BADSINSOARE SEDIMENT SINS TO WET PONDS AFTER AREAS \ A 1 \ — — v I / / / N. 680257.49 STREAM BUFFERA. OUTFACE \ / E. 1324013.34 EMERGENCY ) STRUCTURE 1 40788754ERC,) ^III I (I \ISPILLWAY, WAY. N ro i I ( SEDIMENT TUBES, FW °0 °' r s OUTAH\ DOUBLE ROW, (D 00 �. N. 27 SEE 40788754ERC ) OD E. 1324009.68 6, DETAIL 7 \ OUTFACE HW 8 OUTFALL OIL/WATER OIL/WATER SEPARATOR 2 I STRUCTURE 2 SEPARATOR 1 I v�vv�-- vv vv�Av v v v I �0 I I I / SEE MATTING SLOPE LQ $0- PROTECTION, 40788754ERC, SILT FENCE' ���\� \ \ \ \ I SHEET 5 DETAIL 3 - \ \ SEE 40788754ERC, I I _ I / T_ II SHEET 5, DETAIL 1 SEE MATTING SLOPE I / / EAST WET POND r\1 ( II PROTECTION, SEE I / I( I I I 40788754ERC SHEET 5TEMPORARY SKIMMER F0R/EB AY DETAIL 3BASIN #2v��SEE 40788754ERC,,, I SHEET 8 DETAIL 11 v � v�`.w v`�� �\ \I I 1 \ \ \ I 00 OD 0I IJ I00 N 679947 71 E. 132402798 N. 679896.63 E. 1324026.43 IN \ \ / I / CHANNEL SHALL BE LINED WITH D50 - 15 RIPRAP, THICKNESS SHALL BE 24" DEEP LC/ TEMPORARY �� C\ ^ (/ J — — — / / / N. 679761.42 CATTLE FENCE \ /r / �'<sF — — — — — — — SF / �,��� I�.�\\ �/ —����sF� F j / ---- �/ / // � E. 1323936.42 SILT FENCE A / \\ \ \ �� ROCK DITCH CHECK ` ( — — SEE 40788754ERC, / TEMPORARY SKIMMER \ \ — �\,) / T�� �\ /� �,�� I I /� / �\ /� _ _ _ — SHEET 5, DETAIL 1 — — — SF' r / SEE TYPICAL DETAIL 3 \ \ \1 h SEE 40788754ERC, WHERE ACCESS ROAD — FL SF—S��7D+— 40788754SDR SHEET 4 SHEET 8, DETAIL 11 CROSSES TEMPORARY I /e ( I / / I \ \\i DRAINAGE SWALES, THE Iti /I I / \ \\r N. 679656.20 / SWALES SHALL BE STABILIZED, (\ I / / ' \ 34. (j / / / I � \ I � \ \ / E 13238 34 AT THE END OF _EACH DAY / /��� ROCK DITCH CHECK \ V I I / / TREE BUFFER / ( j' / I // I I / SEE TYPICAL DETAIL 3 / / / `� � H N. 6795888.09 / ............) / I / 40788754SDR SHEET 4 / / % 1 \ v � \%,////////�//////\\, A � -" / / SILT FENCE / `' / / � E 1323809.95 \ , / `� SEE 40788754ERC, o 00 I I y /�' / I / �o� / / / / a v \ SHEET 5, DETAIL 1 I I / ) / //\�` \ � N. 679575.19700 CoI / �� /� / / / IAA \ \ �. 6 \ E 1323740 4 / 1 \ _ — — arolarollullllllllllnal „� / / ✓ i ( 61 �— � I � 1 I \ L \ 00 y ) \ // / / A. !"'lggngqnqqnqqnqqnHqll / I I \ / / _ larioann/ / I in Obi 3 (3) 0000 N I I � / �'1 l�( �N /""nllllllllllllllllllllllllll„l„ol„l n A \ �o V / / l I / / I sp FRO ONT SETSAC V\ N� �\ K LINE 5p�p1---_ N. 679210.88 / �� _ / I /� N. 679116.82 E. 1322819.48 / = \ \ _ — = E. 1323448.14 _ t Z� \ — _ � _ � \ N. 679026.54 J�FRO T — _ — p — \ E. 1323982.59 NT SETBAC—\ SF LI N CONSTRUCTION \ I I I \ ENTRANCE/EXIT I _ (SEE8(SEE 85DETA13SH 4 �IIr I F N. 679125.91 ELBOW ROAD E. 1323391.69 CONSTRUCTION ENTRANCE/EXIT EROSION CONTROL PLAN (SEE 40788754GRA, SCALE: 1 " = 100' PHASE 31 DETAIL 3, SH 4 COMPANION DRAWINGS: 40788754ERC SH 1, 40788754ERC SH 2, 40788754ERC SH 4, 40788754ERC SH 5, 40788754ERC SH 6, 40788754ERC SH 7, 40788754ERC SH 8, 40788754ERC SH 9, 40788754ERC SH 10, 40788754ERC SH 11, & 40788754ERC SH 12 FIRST ISSUE BY W.O. 17757514 ISSUED FOR C01\1STRUCTION LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR — 880-- — EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM • • • • • - EXISTING BARBED WIRE FENCEX— CHAINLINK FENCE CATTLE FENCE x x x x— PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW — OVHD DISTRIBUTION LINE (OVERHEAD) —OE — DISTRIBUTION LINE RIGHT OF WAY _ LIMITS OF DISTURBANCE LODLODLOD p #4 REBAR(S) e #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM co-3 RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE _-RCP = REINFORCED CONCRETE PIPE __CMP _ CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) 11 100 1 100 204 Scale: 1" 11 FILENAME: 40788754ERC-R2. DWG i SIDE40EACK LINE 50.0' / X—x 00 Iv 0 00 \ / / 00 oo / / / �� I I I �, �i � / � I I \ate 00 \ I I °° j I 00 cal // // I °0 0�0 // \\ I/ / ,) 1 MC (TYP) �)— FRONT011 SETBgCK 30 I v �•/ >C\ HG (TYP) 0 _ — I HF (TYP) I — (/ ` �, \ \\ \\ \ cb HF (TYP) � GF (TYP) 30 _ �"o \ \ FRONT SETBq ` ---- �_�� 0 0 MC (TYP) I / ELBOW ROAD Q I 1 \ /O\ I 1 HF (TYP) X II ----------- • TOP OF ROOT BALL SHALL BE 2"-3" • ABOVE SURROUNDING GRADE PAINT ALL CUTS OVER I" DIA. • FLAG GUYING WIRES WITH SURVEYOR TAPE RUBBER HOSE 1" DIA. GUYING WIRES 2 STRAND TWIST 12 GAUGE WIRE (3) ZX4"X24" PRESSURE TREATED STAKES - TOP OF STAKE 6" ABOVE GROUND � ! SPECIFIED PLANTING MIX WATER & TAMP WHILE FILLING TO REMOVE AIR POCKETS- OR AU 2 X BALL DIA. LL U Lv U L V) J J Q w 0 TREE PLANTMG DETAIL NOT TO SCALE LANDSCAPE PLAN SCALE: 1 " = 50' GENERAL NOTES: 1. NO WORK SHALL BEGIN UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN LOCATED AND MARKED BY 811 2. ALL DISTURBED AREAS OUTSIDE OF LANDSCAPE BEDS AND GRAVEL DRIVES SHALL BE SEEDED AND MULCHED FOR PERMANENT STABILIZATION. 3. THE LOCATION OF OVERHEAD UTILITIES SHALL BE NOTED BY CONTRACTOR TO PREVENT CONTACT WITH EQUIPMENT. 4. MULCH SHALL BE AGED SHREDDED HARDWOOD DEBARK PLACED A MINIMUM OF 4" IN DEPTH IN PLANTING BEDS. 5. PLANT MATERIAL SHALL MEET ALL AMERICAN NURSERYMAN ASSOCIATION STANDARDS FOR HEALTH AND SIZE REQUIREMENTS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGES TO THE PROPERTY CAUSED BY THE CONTRACTOR'S WORK. 7. PLANTING BEDS SHALL BE SPRAYED WITH AN APPROVED HERBICIDE PRIOR TO PLANTING IF CURRENTLY VEGETATED WITH LAWN OR WEEDS. 8. PRIOR TO PLANTING, THE CONTRACTOR SHALL FLAG ALL PLANT MATERIAL LOCATIONS FOR APPROVAL BY THE OWNER. 9. PLANT MATERIAL TRANSPORTED TO THE SITE SHALL BE COVERED DURING TRANSIT. 10. PRESSURE WASH ALL PAVED SURFACES IF MUD OR DEBRIS HAS BEEN DEPOSITED BY THE CONTRACTOR'S WORK. COMPANION DRAWINGS: 40788754ERC SH 1, 40788754ERC SH 2, 40788754ERC SH 3, 40788754ERC SH 4, 40788754ERC SH 5, 40788754ERC SH 6, 40788754ERC SH 7, 40788754ERC SH 8, 40788754ERC SH 9, 40788754ERC SH 11, & 40788754ERC SH 12 FIRST ISSUE BY W.O. 17757514 Q 0 J PLANT LIST ORCHARD TIE SUBSTATION I I I I I I I I I I I I I I I I � I I L------------------ ------ LOCATION MAP NOT TO SCALE KEY QUANTITY LATIN NAME ENGLISH NAME SIZE COMMENTS MC 42 MYRICA CERIFERA WAX MYRTLE 5 GAL MIN 6' HIGH PLANTED AT 20' SPACING HF 120 HYPERICUM FRONDOSUM ST JOHN'S WORT 3 GAL MIN 12" HIGH PLANTED 3' SPACING GF 36 GAYLUSSACIA FRONDOSA BLUE HUCKLEBERRY 3 GAL MIN 12" HIGH PLANTED AT 3' SPACING 3" MULCH-\ MAINTAIN SAUCER ON LOWER SIDES OF PLANT TO RETAIN WATER ' IIIIIIIIII " �ry f1=1I1=iI 111111 IIIIIII�IIIIIII BACKFILL WITH SPECIFIED PLANTING MIX WATER AND TAMP WHILE =III= 111— 1-1 =III= FILLING TO REMOVE AIR POCKETS 1�=I1 1�1-11—111=1�1 SCORE AROUND ENTIRE ROOT ALL TOP OF ROOT BALL SHALL BE 2"-3" ABOVE SURROUNDING GRADE rtl SHRUB P G DETAIL NOT TO SCALE EXCAVATE 5" AT EDGE OF BED USE EXCAVATED MATERIAL TO FORM RAISED BERM AT CENTER OF BED 4" LAYER OF MULCH XISTING GRADE PLANT BED PREPARATION NOT TO SCALE ISSUED FOR COAVSTRUCTION REVISION 0 NOTE: CONTENT SHOWN ON THIS DRAWING WAS ORIGINALLY SHOWN ON 40788ERC, SHEET 8. CONTENT WAS ADDED TO NEW SHEET TO MAKE ROOM FOR NEW DETAILS ADDED TO SHEET 8 PER NCDEQ PERMITTING REVIEW COMMENTS. ORIGINAL GRADE OF SLOPE LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR — 880— — EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM • - • • • - EXISTING BARBED WIRE FENCEX— CHAINLINK FENCE CATTLE FENCE xxxx— PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) —OE — DISTRIBUTION LINE RIGHT OF WAY - _ LIMITS OF DISTURBANCE LOD L0D p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE 0 Pt POINT NOT SET CHECK DAM ca.) RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE __RCP = REINFORCED CONCRETE PIPE __CMP CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) 11 50 1 50 100 ■ ■ ■ ■ ■ 1 FILENAME: 40788754ERC-R2.0WG 40'-0" WIDE FOREBAY SPILLWAY WEST WET POND EL. 871.5' FOREBAY EAST WET POND EL. 843.3' EAST FORBAY EL. 840.0' EAST POND EL 841.0', WEST POND EL 872.0' WEST WET POND EL 876.0' WEST FOREBAY EL 865.0 6' WIDE EAST WET POND EL. 845.0 ' RIP -RAP ENERGY SLOPE 6H:1 V DISSIPATOR APRON, 15-0" WIDE EMERGENCY SPILLWAY SEE 40788754SDR VEGETATION SHELF B SEE SHEET 11, EAST POND WEST WET POND EL. 875.0' SHEET 3, DETAIL 1 � SHEET 12, WEST POND EAST WET POND EL. 844.0' 3. MAIN POOL ELEVATION S�OpF EAST POND EL 840.0', WEST POND EL 871.0' POND EL 840.0', WEST POND EL 871.0' \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ - 1--------------------------------------------------------------------------------------------------------------jEAST -------------------------------------------------------------------------------------------- COP ---/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/ r i / EAST POND EL 834.0 WEST .\ X r / POND EL 863.0 / /// - \r\r ///////////////////////////////�/i�/i./i�/i,/�,/�./�./ \//\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\//\\//\\//\\//\//j�//��//%//i\//��//��//;//;//;//��//��/���/i��/i��/i��/��\i��\i\\i\\i\�i\�i\\i\\i\\i�\r�\��\,�\,�\,�\,�\, /.� OVER EXCAVATE FOR EB A Y DEPTH 6" MIN\\;�\\i\�i\�\i\\\i\\i�\i�\��\��\��\\�\\�\\�\\�\\�\\�\\�\\��\��\��\��\��\��\�\/\/\/.�/.�/.� TO ALLOW FOR SEDIMENT ACCUMULATION OVER EXCAVATE POND DEPTH 6" MIN TO ANTI -SEEP ALLOW FOR SEDIMENT ACCUMULATION COLLAR HEADWALL WET POND NOTES: 1. SEE NCDEQ STORMWATER DESIGN MANUAL SECTION C-3 WET POND AND RULE 15A NCAC 2H.1053 MDC FOR WET POND FOR CONSTRUCTION METHODS AND REQUIREMENTS. 13 EAST WET POND SECTION WEST POND SIMILAR) 5'-0" 5'-0" 6 4 -0 6 6 4 -0 0 0 0 o I I -Ln - 0 0 0 o I I r- -Ln 4 WET POND STRUCTURE NOTES: WET POND STRUCTURE NOTES: 1. CONCRETE DESIGN STRENGTH OF 4000 PSI AT 28 DAYS. 2. STEEL REINFORCEMENT SHALL BE ASTM A-615 GRADE 60. 1. CONCRETE DESIGN STRENGTH OF 4000 PSI AT 28 DAYS. 3. INSTALL TRASHRACK GRATES UPON FINAL STABILIZATION. 2. STEEL REINFORCEMENT SHALL BE ASTM A-615 GRADE 60. 3. INSTALL TRASHRACK GRATES UPON FINAL STABILIZATION. _ 7' - 0>, 7'-0" r , TRASHRACK INLET PEAKED ROOF TOP MOUNT GRATE, TRASHRACK MODEL LPK-4848 OR APPROVED EQUAL, ATTACH RACK TO OUTLET TRASHRACK INLET PEAKED ROOF TOP MOUNT STRUCTURE PER MANUFACTURER'S INSTRUCTIONS. GRATE, TRASHRACK MODEL LPK-4848 OR APPROVED EQUAL, ATTACH RACK TO OUTLET EL. 873.0' STRUCTURE PER MANUFACTURER'S INSTRUCTIONS. ORIFICE FOR 3" DIA PIPE TRASHRACK SIDWALL GRATE, EL. 871.0 ' TRASHRACK MODEL LSW-1024 OR EL. 843.0' APPROVED EQUAL, ATTACH RACK TO OUTLET STRUCTURE PER MANUFACTURER'S INSTRUCTIONS. TRASHRACK SIDWALL GRATE, o TRASHRACK MODEL LSW-1024 OR APPROVED EQUAL, ATTACH RACK o ORIFICE RUNGS SHALL BE CONSISTENTLY TO OUTLET STRUCTURE PER FOR 3" o SPACED AND SHALL COMPLY MANUFACTURER'S INSTRUCTIONS. RUNGS SHALL BE CONSISTENTLY DIA PIPE WITH OSHA STANDARDS o SPACED AND SHALL COMPLY WITH OSHA STANDARDS EL. 840.0' OPENING FOR 18" ADS OPENING FOR 18" ADS 18" ADS PIPE 18" ADS PIPE m o- Q > cn ` MIN SOIL COVER -' ��/ \��� \�I O o bi 0 i� OVER BASE SLAB 0 e J Q O ��\ i 1.00' 0 0 1.00 0 1.00' i 1.00 1.00' o O 1.00 `c' EL. 836.0' �� Ld z > EL. 863.0' ' O EAST WET POND INTERIOR OUTFALL STRUCTURE WEST WET POND INTERIOR OUTFALL STRUCTURE 14 WET POND OUTLET STRUCTURE ISSUED FOR 40.00' C'01\\ISTRUCTION RIP -RAP, 12" D50 /77777777 40'-0$' WIDE FOREBAY SPILLWAY COMPANION DRAWINGS: 40788754ERC SH 1, 40788754ERC GEOTEXTILE FABRIC WEST WET POND EL. 872.0' SH 2, 40788754ERC SH 3, 40788754ERC SH 4, 40788754ERC EAST WET POND EL. 845.0' 0 ISSUED FOR CONSTRUCTION REV DESCRIPTION NEW WORK FF9193C1 JED/MESA I LHH/MESA WED/MESA/WW 11/13/2018 ISSUE TYPE DPN DFT DES/CHK ENG DATE WEST WET POND EL. 871.5' \�� SH 5, 40788754ERC SH 6, EAST WET POND EL. 843.3' // // // // // // //\/ 40788 54ERC SH 7, 40788754ERC REVISION HISTORY / \ \\ \\ \\ \\ \ \\ \\ \\�\ 40788754ERC SH 10, 40788754ERC \//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\/ SH 11, & 40788754ERC SH 12 SEAL: THIS HR1TVIV, OR ❑ PRELIMINARY TITLE: EROSION CONTROL DETAILS N BILL O-VATER1,1L 1 ❑ AS BUILT Z E R O /�/�/�/�/�/�/�/�/�/�/�/�/�/�/�i ,�•`:�N�GARp'�% co�1'111L�1'11L .. �.............<,-,� � BE 230-100kV SUBSTATION v\�\�X FIRST ISSUE BY W. 0.17757514 'O CI10AND 0 , PI F,1'NOT ROD T FH Contract:EAL Mesa Associates, PLLC _ 0R COPIF H, F,ITHF,R 41.0-11,%6553- MOLL) 0I� I \' Y�1KT. Company: = LOCATION:ORCHARD Engineers Consultants TIE and ;�=-. : �, OR 19DL Pu13L1C 1.� 629 Market Street, Suite 200 Chattanooga TN 37402-4802 <<�•�!+�GIN_E..—"(P-� ���'Y ���A��N�� �F1T110�T Pnone: '',,�M E. I)V--x THE iI RITTF,1' DUKE CITY: NEWTON COUNTY: CATAWBA STATE: NC SHEET SIZE: REGION: STATION NUMBER: DRAWING NUMBER: REV: Tel. 423 424-7300 r` �� � �II �3 �� 01�' UL E L'AERGY Date: ENERGY® ARCH D - NC SC 2753 40788754ERC 0 15 SECTION B-B FOREBAY SPILLWAY NC Engr. Cert. No.: P-0193 CORiPOR41'10:1. SHEET 10 OF 12 FILENAME: 40788754ERC-R2. DWG ORCHARD TIE SUBSTATION m PLANT LIST KEY QTY LATIN NAME ENGLISH NAME SIZE CT 171 CAREX TENERA QUILL SEDGE PLUG, 4 in MINIMUM JT 323 JUNCUS TENUIS PATH RUSH PLUG, 4 in MINIMUM PV 152 PANICUM VIRGATUM SWITCHGRASS PLUG, 4 in MINIMUM SB 171 SACCHRUM BREVIBARBE NARROW PLUME GRASS PLUG, 4 in MINIMUM LE 171 LOBELIA ELONGATA LONGLEAF LOBELIA PLUG, 4 in MINIMUM \ IN, r0 EAST POND VEGETATION PLAN SCALE: 1 " = 20' i 2 0' BOTTOM OF (TYP) VEGETATIVE SHELF CT JT CT JT CT JT CT JT CT JT CT JT CT JT CT JT CT o a- � N � `J JT PV JT PV JT PV JT PV JT PV JT PV JT PV JT PV JT SB SB SB LE LE LE SB SB SB LE LE LE SB SB SB LE LE TYPICAL PLANTING ARRANGEMENT COMPANION DRAWINGS: 40788754ERC SH 1, 40788754ERC SH 2, 40788754ERC SH 3, 40788754ERC SH 4, 40788754ERC SH 5, 40788754ERC SH 6, 40788754ERC SH 7, 40788754ERC SH 8, 40788754ERC SH 9, 40788754ERC SH 10, & 40788754ERC SH 12 FIRST ISSUE BY W.O. 17757514 TOP OF VEGETATIVE SHELF ISSUED FOR CO1\1STRUCTION LOCATION MAP NOT TO SCALE NOTES: 1. PLANTING PERMITTED ABOVE WATERLINE AT ANY TIME OF THE YEAR. 2. INSTALL NON —CLUMPING TURF GRASS ON EMBANKMENTS, EG. KENTUCKY 31 TALL FESCUE. 3. PLANT VEGETATIVE SHELF AT A MINIMUM DENSITY OF 50 PLANTS PER 200 SQUARE FEET. LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR — 880— EXISTING TOPO MINOR CONTOUR---------- 1 1 20 40 •1 ■ ■ ■ ■ ■ 1 FILENAME: 40788754ERC-R2. DWG 7r,r, S27' WEST POND VEGETATION PLAN SCALE: 1 " = 20' PLANT LIST KEY QTY LATIN NAME ENGLISH NAME SIZE CT 162 CAREX TENERA QUILL SEDGE PLUG, 4 in MINIMUM JT 306 JUNCUS TENUIS PATH RUSH PLUG, 4 in MINIMUM PV 144 PANICUM VIRGATUM SWITCHGRASS PLUG, 4 in MINIMUM SB 162 SACCHRUM BREVIBARBE NARROW PLUME GRASS PLUG, 4 in MINIMUM LE 162 LOBELIA ELONGATA LONGLEAF LOBELIA PLUG, 4 in MINIMUM P. 0 2 0' BOTTOM OF (TYP) VEGETATIVE SHELF CT JT CT JT CT JT CT JT CT JT CT JT CT JT CT JT CT 0F�>_ 0 JT PV JT PV JT PV JT PV JT PV JT PV JT PV JT PV JT SB SB SB LE LE LE SB SB SB LE LE LE SB SB SB LE LE TYPICAL PLANTING ARRANGEMENT COMPANION DRAWINGS: 40788754ERC SH 1, 40788754ERC SH 2, 40788754ERC SH 3, 40788754ERC SH 4, 40788754ERC SH 5, 40788754ERC SH 6, 40788754ERC SH 7, 40788754ERC SH 8, 40788754ERC SH 9, 40788754ERC SH 10, & 40788754ERC SH 11 FIRST ISSUE BY W.O. 17757514 TOP OF VEGETATIVE SHELF i i i i i ORCHARD TIE i SUBSTATION i i i ISSUED FOR COAVSTRUCTION L 0 CA TION MAP NOT TO SCALE NOTES: 1. PLANTING PERMITTED ABOVE WATERLINE AT ANY TIME OF THE YEAR. 2. INSTALL NON —CLUMPING TURF GRASS ON EMBANKMENTS, EG. KENTUCKY 31 TALL FESCUE. 3. PLANT VEGETATIVE SHELF AT A MINIMUM DENSITY OF 50 PLANTS PER 200 SQUARE FEET. LEGEND PROPERTY LINE TOPO MAJOR CONTOUR TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR EXISTING TOPO MINOR CONTOUR �� � Z9=1 1 1 20 40 •1 ■ ■ ■ ■ ■ 1 FILENAME: 40788754ERC-R2. DWG ORCHARD TIE SUBSTATION 16.0 WIDE TOWER ACCESS ROADmo l / I l - x��� �� N. 680639.02 vo / J x x -- _ �/ - E. 1323691.42 I Lx x-x i , - ) I x �860 EL. 87�.0 1 1\ \ \\ \ N. 680592.50 E. 1322967.91 72 5.00' EL. 877.0' % �L \��1,� 362.50 U '362.50,-LOD- LODE o X I I� I CENTERLINE OF RD EDGE OF RD C9 / x/ / EDGE OF RD EL 877.93 -l' C8 CB 1 EL 877.93 CENTERLINE �, o OD CB 7 J J O O OF RD �, � WEST POND EL�877.64' EDGE OF RD I r EDGE OF RD FOREBAY POOL i - \ EL 877.42' SLOPE 1 % / //�j� EL 871.5 o I CB 14 EL 877.42 SLOPE / E 1% / SLOPE SLOP 1.25% 1.257o - CB 2 CB 8 SUBSTATION / PAD II I { \ \ \ WEST POND x r 0, I EDGE OF RD II 1 \ \ \ MAIN POOL EL l \ CB 9 1 I \ I \ I EL 877.42 871.0 X \ 3:1 CENTERLINE OF ROAD / CB 3 CENTERLINE OF ROAD EL 877.64' EL 877.64 N. 680223.07% � _ 1 X 0 N. 680178.92 E. 1323699.62 STREAM 1 \ / BUFFER \ I I l \ \ N I R5p 0 E. 1323013.04 C o ° 4:1 Lo \00 -to 00 I / � V \ o \� SLOPE 1 00 )L \\ ✓ I ` \ o +1210R50 EDGE OF RD M X� / I r �( v x 0 00 EL 877.93 CB 10 / 3:1 EAST POND MAII\ SLOPE 1 % CB 4 SL CB 11 � � I POOL EL 840.0' LOPE X .25% $� CB 5 CB 12 AOCAOOITNAOF��\� EDGE OF RD CENTERLINE OF RD I STREAM 5 PER \ �� I 0 EL 877.64' I I EL 877.42 N. 679796.85 I , NRA REPORT \\ EDGE OF RD EAST POND i E. 1323217.16 I FOREBAY POOL SLOPE EL 877.42' \ �`�\\�\\\�\\~_\`��✓���\\�- -\ I N. 679766.91 � o 41 I EL 843.3' w E. 1323219.08 I / \ \ \ \\ / CB 6 EL 877.5 CB 13 I EDGE OF RD C10 4 EDGE OF RD o EL 87 C7 EL 877.93 0- - CENTERLINE OF RD' W /� EL 877.64' rTl �� ' _ - _ - N. 679835.69 197.680 / I ✓ �� \ \ \ N. 679754.23 E. 1323743.39 \ \ \ \\ \ to -J X E. 1323021.81 ' / EL. 877.0' EL 877.0'- r- '`� SETBACK LINE '50.0'� / - SIDE�- / 100� N N. 679677.99 EAST POND 7-1/E. 1323175.52 ACCESS ROAD / TlT7 / 20 - SPOILS ARE 00 TREE BUFFER ° 00 (0 / °' °° N \ 16.0' WIDE TOWER v�E 50.0,`� �� / ACCESS ROAD o o 16.0' WIDE TOWER o. / -ACCESS ROAD \ I I SUBSTATION x _ Z ACCESS ROAD \ / ANT SETB \ \ GRADING PLAN SCALE: 1" = 100' 18" CMP resW"a Q 0 J -&lq 41!& L 0 CA TION MAP NOT TO SCALE NOTE: 1. OVER EXCAVATE THE WET POND FOREBAYS AND MAIN POOLS BY 6" TO ALLOW FOR SEDIMENT ACCUMULATION. CURVE TABLE CURVE # LENGTH RADIUS DELTA CHORD LENGTH NORTHING START EASTING START NORTHING END EASTING END C7 117.81 75.00 90.0000 106.07 679808.63 1323032.34 679808.63 1323112.00 C8 117.81 75.00 90.0000 106.07 680500.38 1323062.40 680500.38 1322992.37 C9 117.81 75.00 90.0000 106.07 680614.56 1323678.96 680614.56 1323599.30 C10 117.81 75.00 90.0000 106.07 679922.81 1323648.90 679922.81 1323718.93 COMPANION DRAWINGS: 40788754GRA SH 2, 40788754GRA 3, 40788754GRA SH 4, 40788754GRA SH 5, 40788754GRA SH 6, 40788754GRA SH 7, 40788754GRA SH 8, 40788754GRA SH 9, & 40788754GRA SH 10 FIRST ISSUE BY W.O. 17757514 LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR 880 EXISTING TOPO MINOR CONTOUR - - - - - - - EXISTING STREAM - - - EXISTING BARBED WIRE FENCE X X X X X- CHAINLINK FENCE CATTLE FENCE X X PRE -CONSTRUCTION DRAINAGE AREA - - POST -CONSTRUCTION DRAINAGE AREA • • • • - SILT FENCE SF SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW - OVHD DISTRIBUTION LINE (OVERHEAD) -OE - DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LODLOD El #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM co-) RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE -RCP REINFORCED CONCRETE PIPE -CMP CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUED FOR C01\1STRUCTION 11 1 11 1� 1� N w FILENAME: 40788754GR4-R2. DWG ORCHARD TIE SUBSTATION 880 879 878 877 876 875 874 873 872 871 870 869 868 867 866 865 864 m 863 862 0 861 860 859 858 857 856 855 854 853 852 851 850 849 848 847 846 845 844 GRADE BREAK STA = 0+00.00 ELEV = 877.53 1 64.261 VC 97.172VC GRADE BREAK STA = 6+74.61 133.261 VC ELEV = 873.49 LLLV = oo,-).Uy GRADE BREAK STA ELEV = 4+65.07 = 865.89 -0.55% EXISTING GRADE GRADE BREAK STA = 1+03.88 ELEV = 876.96 \3 86q [EXISTING GRADE NEW GRADE �6 809 0 GRADE BREAK STA = 8+07.87 ELEV = 846.67 -3 j0 0 GRADE BREAK STA = 8+40.42 ELEV = 845.66 0+00 0+25 0+50 0+75 1+00 - vJ� Tn- E. 1323175.52 IrtLJ It/J LtLJ Z- /J JrtLJ Jt/J `FrtLJ `Frt/J JrtLJ Jt/J OrtLJ Ort/J /rtLJ /rt/J OrtLJ 1 +50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 CURVE TABLE CURVE # LENGTH RADIUS DELTA CHORD LENGTH NORTHING START EASTING START NORTHING END EASTING END C4 21.93 100.00 12.5675 21.89 679705.86 1323624.50 679705.86 1323646.37 C5 144.17 111.71 73.9464 134.37 679746.62 1323752.97 679746.62 1323875.38 Q 0 J L 0 CA TION MAP NOT TO SCALE LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR 880 EXISTING TOPO MINOR CONTOUR - - - - - - - EXISTING STREAM - - EXISTING BARBED WIRE FENCE X X-XX X- CHAINLINK FENCE CATTLE FENCE -xxxx- PRE-CONSTRUCTION DRAINAGE AREA - - POST -CONSTRUCTION DRAINAGE AREA • • • • - SILT FENCE SF -SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) -OE - DISTRIBUTION LINE RIGHT OF WAY - LIMITS OF DISTURBANCE LOD L0D p #4 REBAR(S) A #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM � RETAIL POWER POLE TRANSMISSION TOWER le WOODS LINE _RCP REINFORCED CONCRETE PIPE _CMP CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUED FOR COAVSTRUCTION N W ry FILENAME: 40788754GR4-R2. DWG �// FORE I I I \ RIP \ \ \ AF WE MAIN \ \ \ EMERGENCY -� SPILL AND \ RIP RAP APRONS I 1 HW 2 1 \ \\\\\\\ RIAPRON - /� JC. \ - / 11 X�x i STORM DRAINAGE PLAN SCALE: 1 " = 100' SEE 40788754SDR, SHEET 3, DETAIL 1 TYPICAL HEADWALL // 'AND RIP RAP APR( EAST POND MAIN POOL EL 840.0' ISSUED FOR C01\1STRUCTION i i i ORCHARD TIE i SUBSTATION i a 0 J DRAINAGE STRUCTURE TABLE i STRUCTURE NAME RIM EL. NORTHING EASTING STRUCTURE SIZE LID TYPE CB-1 RIM = 877.18 680528.05 1323010.63 48 X 48 RECT STRUCTURE GRATE � PIPE 1 INV OUT = 873.90 i L RIM = 877.18 CB-2 PIPE 2 INV IN = 871.26 680378.36 1323020.26 48 X 48 RECT STRUCTURE GRATE PIPE 22 INV OUT = 871.26 NO RIM = 877.18 1. 2 CB-3 PIPE 3 INV IN = 872.01 680228.67 1323029.88 48 X 48 RECT STRUCTURE GRATE PIPE 2 INV OUT = 872.01 RIM = 877.18 CB-4 PIPE 4 INV IN = 872.70 680091.81 1323038.68 48 X 48 RECT STRUCTURE SPCC 13 INV IN = 872.70 GRATE PIPE 3 INV OUT = 872.70 RIM = 877.18 CB-5 PIPE 5 INV IN = 873.15 680001.41 1323044.49 48 X 48 RECT STRUCTURE GRATE PIPE 4 INV OUT = 873.15 CB-6 RIM = 877.18 679851.72 1323054.12 48 X 48 RECT STRUCTURE GRATE PIPE 5 INV OUT = 873.90 CB-7 RIM = 877.18 680569.63 1323657.30 48 X 48 RECT STRUCTURE GRATE PIPE 8 INV OUT = 873.19 RIM = 877.18 CB-8 PIPE 8 INV IN = 871.69 680419.94 1323666.92 48 X 48 RECT STRUCTURE GRATE PIPE 9 INV OUT = 871.69 RIM = 877.18 CB-9 PIPE 9 INV IN = 870.19 680270.25 1323676.55 48 X 48 RECT STRUCTURE GRATE PIPE 10 INV OUT = 870.19 RIM = 877.18 CB-10 PIPE 10 INV IN = 869.04 680155.70 1323683.91 48 X 48 RECT STRUCTURE GRATE PIPE 11 INV OUT = 869.04 RIM = 877.18 CB-11 PIPE 11 INV IN = 868.81 680133.05 1323685.37 48 X 48 RECT STRUCTURE SPCC 6 INV IN = 868.81 GRATE PIPE 12 INV OUT = 868.81 RIM = 877.18 CB-12 PIPE 12 INV IN = 867.91 680042.99 1323691.16 48 X 48 RECT STRUCTURE GRATE PIPE 13 INV OUT = 867.91 RIM = 877.18 CB-13 PIPE 13 INV IN = 866.41 679893.30 1323700.79 48 X 48 RECT STRUCTURE GRATE PIPE 14 INV OUT = 866.41 RIM = 877.18 CB-14 PIPE 22 INV IN = 870.91 680447.67 1323015.80 48 X 48 RECT STRUCTURE PIPE 1 INV IN = 870.91 GRATE P LP E 6 INV O T = 0. 1 8 HW-1 RIM = 874.59 680443.60 1322953.27 070 X 12 X 55 CONCRETE WINGED HEADWALL N/A PIPE 6 INV IN = 870.76 HW-2 RIM = 862.02 680147.30 1322829.95 054 X 12 X 55 CONCRETE WINGED HEADWALL N/A PIPE 7 INV IN = 859.89 HW-3 RIM - 867.7 679771.70 1323708.61 70 X 12 X 77 CONCRETE WINGED HEADWALL N/A PIPE 14 INV IN = 864.00 HW-4 RIM = 875.67 679724.01 1323189.09 54 X 12 X 45 CONCRETE WINGED HEADWALL N/A PIPE 15 INV OUT = 874.00 HW-5 RIM = 874.67 679712.74 1323141.29 054 X 12 X 45 CONCRETE WINGED HEADWALL N/A PIPE 15 INV IN = 873.25 HW-8 RIM = 837.21 680214.96 1323979.26 054 X 12 X 45 CONCRETE WINGED HEADWALL N/A PIPE 19 INV IN = 835.00 HW-9 RIM = 846.21 679801.28 1323930.81 54 X 12 X 45 CONCRETE WINGED HEADWALL N/A PIPE 18 INV OUT = 844.00 HW-10 RIM = 846.01 679824.43 1323948.20 54 X 12 X 45 CONCRETE WINGED HEADWALL N/A PIPE 18 INV IN = 843.80 HW-11 RIM = 868.90 679183.24 1323355.52 018 INCH FLARED END SECTION 67 X 74 N/A PIPE 17 INV OUT = 866.50 HW-12 RIM = 866.90 679173.34 1323409.36 018 INCH FLARED END SECTION 67 X 74 N/A PIPE 17 INV IN = 864.50 OS-1 RIM = 873.00 680169.63 1322920.38 48 X 48 RECT STRUCTURE STORM PIPE 7 INV OUT = 864.27 TECH OS-2 RIM = 843.00 680169.30 1323931.01 48 X 48 RECT STRUCTURE STORM PIPE 19 INV O T= 8 6. 0 T CH COMPANION DRAWINGS: 407887564SDR SH 2, 40788754SDR SH 3, & 40788754SDR SH 4 FIRST ISSUE BY W.O. 17757514 �O ------ LOCATION MAP NOT TO SCALE TES: ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III. ALL ADS N-12 HDPE PIPE AND FITTING SHALL BE DOUBLE WALL WITH WATER TIGHT JOINTS. PIPE TABLE PIPE LABLE oftoft SIZE LENGTH SLOPE START STRUCTURE END TRUCTURE PIPE 1,00" 15 80.55 on 3.71 % CB-1 CB-1woor"WSMO4 PIPE 2 3 50.0 0.50% CB-2 CB-3 PIPE 3 30 137.14 0.50% CB-4 CB-3 PIPE 4 24 90.59 0.50% CB-5 CB-4 PIPE 5 18 150.00 0.50% - CB - PIPE 6 36 62.66 0.25% CB-14 HW-1 PIPE 7 18 92.30 4.77% OS-1 HW-2 PIPE 8 18 150.00 1.00% CB-7 CB-8 PIPE 9 30 150.00 1.00% CB-8 CB-9 PIPE 10 30 114.78 1.00% CB-9 CB-10 PIPE 11 30 22.69 1.00% CB-10 CB-11 PIPE 12 30 90.25 1.000 CB-11 CB-12 PIPE 13 36 150.00 1.00% CB-12 CB-13 PIPE 14 36 121.85 1.98% CB-13 HW-3 PIPE 15 12 48.45 1.55% HW-4 HW-5 PIPE 17 18 54.74 3.65% HW-11 HW-12 PIPE 18 24 28.42 0.70% HW-9 HW-10 PIPE 19 18 66.44 1.51% OS-2 HW-8 PIPE 20 12 54.37 1.10% PIPE 21 12 51.89 1.06% PIPE 22 36 69.45 j 0.50% j CB-14 CB-2 - - - - - - - - - - - LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR 80- - EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM EXISTING BARBED WIRE FENCE -X X X X-X- CHAINLINK FENCE CATTLE FENCE x x x x- PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA - - - SILT FENCE SF SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) -OE - DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LoD L0D p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM � RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE __RCP _ REINFORCED CONCRETE PIPE __CMP _ CORRUGATED METAL PIPE CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) 1/ 1 11 11 11 11 FILENAME: 40788754SDR-R2. DWG i i i i i ORCHARD TIE ' SUBSTATION i i i i i i i i i i i ' o 8 � lqc��� � MAIDEN b RIB -111� M EN i i �& L--------------------------------------------------------------- L 0 CA TION MAP NOT TO SCALE LEGEND PROPERTY LINE — — TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR — 880— — EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM • • - • • - EXISTING BARBED WIRE FENCE XX—XXX- CHAINLINK FENCE CATTLE FENCE —xxxx— PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA — — — SILT FENCE SF —SF* TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) —OE — DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LODLOD p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET qECgD CHECK DAM co-3 RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE _-RCP = REINFORCED CONCRETE PIPE _-CMP _ CORRUGATED METAL PIPE CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUED FOR C01\1STRUCTION FIRST ISSUE BY W.O. 17757514 N W FILENAME: 40788754SDR-R2. DWG SOUTH FORK - o CATAWR -� Ill 1l 1111 \\\\\\�\ \ a BA RIVE � — - , �-\\\�\111 I I III II 1 II � \\ \\ R, ��\— v^-�,����\\\\\�\,V �� , ��� �\ \\\ \ _ III \\\\\\� /X, DRAINAGE AREA DRAINARE 2 AGE E ��............... _ 'AREA = 40.141-- Au. — i �� f -�.,� ✓ 8 x� // // /III I I l l I I \ II / / � -- DRAINAGE AREA 3 AREA = 35.45f AC. � �j/ ✓ � � � ��\\ I I III I � �_ — / -�\\ \�\ �\ ' \� AREA = 34.60E \ BEL AIRANI \ \ \ \ POND 1 \ \ \ �\\\� \\\� \ \\� \ \ \ \ \ \ \ \ \\ 89 qc 00 if DRAIN AGE AREA 4 `AREA = 109.16E AC. \\ \� -- / 2 f-�— _ • o � , / REV COMPANION DRAWINGS: 40788754DRG SH 1, 40788754DRG SH 2, 40788754DRG SH 3, SEAL: 40788754DRG SH 5, 40788754DRG SH 6, 40788754DRG SH 7, & e�.N 40788754DRG SH 8 ��F, FIRST ISSUE BY W.O. 17757514 ;.2.0, ill � , ► .. I � /ii�, . , � // . I i � / OVERALL POST —CONSTRUCTION DRAINAGE MAP SCALE: 1 " = 200' Q 0 J ORCHARD TIE SUBSTATION L 0 CA TION MAP NOT TO SCALE LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR 880 EXISTING TOPO MINOR CONTOUR — — — — — — — EXISTING STREAM - - - EXISTING BARBED WIRE FENCE XX—XXX- CHAINLINK FENCE CATTLE FENCE —xxxx— PRE—CONSTRUCTION DRAINAGE AREA — — POST —CONSTRUCTION DRAINAGE AREA • • • • - SILT FENCE_SF SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW — OVHD DISTRIBUTION LINE (OVERHEAD) ❑E DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LOD LOD p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM ca., RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE _RCP REINFORCED CONCRETE PIPE _CMP CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUED FOR C01\1STRUCTION 400 ..... .. 200 ... .. N w FILENAME: 40788754DRG-R2. D WG _ r - \ ) DRAINAGE AREA 2 AREA = 40.14E AC. — / — � 1 i / x/� J ................. TREE BUFFER NN' 71 \�\DRAINAGE AREA 1AREA 34.60± AC. AI _ STREAM BUFFER\\VA\� \\ \ �- / so \ \ \\ \ DRAINAGE AREA 5/.. / / AREA = 4.49E ..AC. TREE BUFFER �' J POST -CONSTRUCTION DRAINAGE MAP SCALE: 1 " = 100' Q 0 J COMPANION DRAWINGS: 40788754DRG SH 1, 40788754DRG SH 2, 40788754DRG SH 3, 40788754DRG SH 4, 40788754DRG SH 6, 40788754DRG SH 7, & 40788754DRG SH 8 FIRST ISSUE BY W.O. 17757514 ORCHARD TIE SUBSTATION -&lq 41!& --------- LOCATION MAP NOT TO SCALE LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR 880 EXISTING TOPO MINOR CONTOUR — — — — — — — EXISTING STREAM - - - EXISTING BARBED WIRE FENCE —X X X X—X— CHAINLINK FENCE CATTLE FENCE x x x x— PRE—CONSTRUCTION DRAINAGE AREA — — POST —CONSTRUCTION DRAINAGE AREA • • • • - SILT FENCE SF SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) —OE DISTRIBUTION LINE RIGHT OF WAY LIMITS OF DISTURBANCE LODLOD p #4 REBAR(S) ♦ #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET CHECK DAM ca) RETAIL POWER POLE TRANSMISSION TOWER WOODS LINE —RCP REINFORCED CONCRETE PIPE —CMP CORRUGATED METAL PIPE ® CLEARING LIMITS (SUBSTATION) CLEARING LIMITS (TRANSMISSION LINE) ISSUWD F0_111-' Col\ls TRUCTIO AV 11 11 1 11 11 - 11 FILENAME: 40788754DRG-R2. D WG LOD_ LAD- L00� LOD-� LAD- LOD-J,+L o-- LODL LADS LOD— L' LOD- LOD- L00 - LOD- LODE LAD- LOD- v' LODE LODE LAD- LODE 0 0 Bp: 0+00.00 f o- 0 _ I / i I / r 00 CB 1 00 I I rol i ��• ��` Cif 1.11 Ilu�l�llll ►,.. �Ilj L.-l--� jli%j�llj jln j 1 ��• � 11il,j�ll� ��• ��; ���� jCl�jl�llj 11��1� •• •� •• � jl{I�j�lll 11/1�111 i 1I@,IIall. IIC\I,�IIj - •• • I •Ill��l�llj jlll�j • jill jELI •• Imo'' •• ►�,��I���I I •- YI- ii\-OS MH 3 spcc io,7 C C 11 -• S CC 12 -OS MH 4 U Of FA i LJ � SPCC 13 II II II I / I o 0 \) CB 5 \\ I II II 00 I o l 00 I I� 0 � III I I ICB 6 � � I I / I I ❑-- J RELAY H I I I I I CB 8 I I I I I I I I I I CB 9 00 0) OS MH 1 OS CB 3 OS CB 2 _ - OS CB 1 _ C 2 - - - I -' SPCC 1 ___-_____-- ir ' -SPCC 7 SPCC 3 \ SPCC 8 \ C 4 �-4-OC (FUTURE) TRANSFO_ M_ ER OC F10 OIL/WATER OC F11 B '; - -- SEPARATOR 1 ,} OS MH 2 SPCC 6 c L LJ CB 12 - o0 ❑� 00 Cq • J 0 0 0 a0 �I Q0 00 0 T a v , 0 2 o e a 0 L LJ CABLE TRENCH (TYP) SPCC PLAN SCALE: 1 " = 50' ISSUED FOR C 0 NS TR UC TI 0 N CB 13 CB 10 I. II SPCC 5 I II '0 CB 11 I I I I I I I I I I I I I I � i /I QC Q 0 J DRAINAGE STRUCTURE TABLE STRUCTURE NAME RIM EL. NORTHING EASTING STRUCTURE SIZE LID TYPE IM = 878.851 36 X 36 OS CB 1 SPCC 1 INV IN = 875.35 680195.18 1323468.34 RECT STRUCTURE GRATE SPCC 2 INV OUT = 875.35 RIM = 878.08 OS CB 2 SPCC 7 INV IN = 874.66 680199.40 1323533.96 36 X 36 GRATE SPCC 2 INV IN = 874.66 RECT STRUCTURE SPCC 3 INV OUT = 874.66 RIM = 879.96 36 X 36 OS CB 3 SPCC 8 INV IN = 876.41 680188.01 1323356.92 RECT STRUCTURE GRATE SPCC 9 INV OUT = 876.41 RIM = 879.33 OS CB 4 SPCC 9 INV IN = 875.75 680183.76 1323290.83 36 X 36 GRATE SPCC 14 INV IN = 875.60 RECT STRUCTURE SPCC 10 INV OUT = 875.75 RIM = 879.37 ECCENTRIC OS MH 1 SPCC 3 INV IN = 873.49 680206.50 1323644.47 STRUCTURE 48 DIA STANDARD SPCC 4A INV OUT = 873.48 RIM = 878.60 ECCENTRIC OS MH 2 SPCC 5 INV IN = 869.81 680131.84 1323666.56 STRUCTURE 48 DIA STANDARD SPCC 6 INV OUT = 869.75 RIM = 879.38 ECCENTRIC OS MH 3 SPCC 10 INV IN = 873.49 680169.56 1323069.86 STRUCTURE 48 DIA STANDARD SPCC 11A INV OUT = 873.49 RIM = 878.06 ECCENTRIC OS MH 4 SPCC 12 INV IN = 872.07 680093.02 1323057.49 STRUCTURE 48 DIA STANDARD SPCC 13 INV OUT = 871.98 RIM = 877.18 CB-4 PIPE 4 INV IN = 872.70 680091.81 1323038.68 48 X 48 GRATE SPCC 13 INV IN = 872.70 RECT STRUCTURE PIPE 3 INV OUT = 872.70 RIM = 877.18 CB-11 PIPE 11 INV IN = 868.81 680133.05 1323685.37 48 X 48 GRATE SPCC 6 INV IN = 868.81 RECT STRUCTURE PIPE 12 INV OUT = 868.81 COMPANION DRAWING: 40788754SPC SH 2 FIRST ISSUE BY W.O. 17757514 ORCHARD TIE SUBSTATION • I U � e�> I I I I I I I I I I I I L----------------- ------------------ --_ LOCATION MAP NOT TO SCALE PIPE TABLE PIPE LABLE SIZE LENGTH SLOPE START STRUCTURE URE STRUCTURE MATERIAL SPCC 1 15 5.11 0.98% OC F11 B OS CB 1 In D E ETBL WA SPCC 2 24 65.75 1.05% OS CB 1 OS CB 2 RCP, CLASS III SPCC 3 24 110.74 1.06% OS CB 2 OS MH 1 RCP, CLASS III SPCC 4 24 21.59 1.02% OS MH 1 OIL/WATER SEPARATOR 1 PVC SCH 40 SPCC 5 24 7.59 2.50% OIL/WATER SEPARATOR 1 OS MH 2 PVC SCH 40 SPCC 6 24 18.85 4.99% OS MH 2 CB-11 HDPE DBL WALL SPCC 7 15 5.70 1.05% OC (FUTURE) OS CB 2 HDPE DBL WALL SPCC 8 15 5.70 1.05% OC F10 OS CB 3 HDPE DBL WALL SPCC 9 24 66.22 1.00% OS CB 3 OS CB 4 RCP, CLASS III SPCC 10 24 221.43 1.02% OS CB 4 OS MH 3 RCP, CLASS III SPCC 11 24 21.59 1.02% OS MH 3 OIL WATER SEPARATOR 2 PVC SCH 40 SPCC 12 24 7.25 0.97% OIL WATER SEPARATOR 2 OS MH 4 PVC SCH 40 SPCC 13 24 18.85 3.80% OS MH 4 CB-4 HDPE DBL WALL SPCC 14 15 5.03 3.907 OC F11 A OS CB 4 HDPE DBL WALL LEGEND PROPERTY LINE TOPO MAJOR CONTOUR 880 TOPO MINOR CONTOUR EXISTING TOPO MAJOR CONTOUR - 880- - EXISTING TOPO MINOR CONTOUR ------------- EXISTING STREAM • • - • • - EXISTING BARBED WIRE FENCE-x-x-x-x-x- CHAINLINK FENCE CATTLE FENCE -xxxx- PRE-CONSTRUCTION DRAINAGE AREA - - - - - - POST -CONSTRUCTION DRAINAGE AREA - - - SILT FENCE SF SF TEMPORARY DRAINAGE SWALE TDS-TDS DIRECTION OF FLOW OVHD DISTRIBUTION LINE (OVERHEAD) -DE - DISTRIBUTION LINE RIGHT OF WAY p #4 REBAR(S) 0 #3 REBAR(F) ■ #4 REBAR(F) • MAG NAIL(F) Q #6 REBAR(S) 2 (F) FOUND (S) SET C/L. = CENTER LINE o Pt POINT NOT SET NOTE: OJM CHECK DAM 1. SEE DRAWINGS 40788754SPC01, SPCO2,& SPC03 FOR SPCC CONTAINMENT PLAN, ca, RETAIL POWER POLE NOTES, AND DETAILS. TRANSMISSION TOWER WOODS LINE -RCP _ REINFORCED CONCRETE PIPE __CMP _ CORRUGATED METAL PIPE CLEARING LIMITS (SUBSTATION) 50 0 50 100 150 CLEARING LIMITS (TRANSMISSION LINE) Scale: 1" = 50' N LU FILENAME: 40788754SPC-R2. DWG