Loading...
HomeMy WebLinkAboutInfinity - Project Infinity Storm Water Calc Report 2.28.2018 (2)    TABLE OF CONTENTS I. NARRATIVE Introduction Storm Water Management Requirements Existing Site Conditions Proposed BMP Design Conclusions II. MAPS AND FIGURES HydroCAD Model Diagram Pre and Post Drainage Area Maps NOAA Rainfall Data Location Map Soils Map USGS Map FEMA FIRM Map III. HYDROCAD MODEL OUTPUT Hydrocad: 1-Inch Storm Event (Modified P) Hydrocad: 10-yr 6-hr Storm Event Hydrocad: 50yr 6-hr Storm Event IV. STORM WATER Hydraulic Calculations Storm Sewers Design          INTRODUCTION TKC Land Development II, LLC is proposing the construction of a new 100,000 SF industrial facility with a future 50,000 SF expansion option located at 115 Summit Park Drive in the Summit Corporate Center in Rowan County, North Carolina. The purpose of this report is to show that the proposed storm water management BMP associated with these improvements will meet or exceed the state of North Carolina’s storm water requirements as well as the requirements of the Rowan County and the Summit Corporate Center. STORM WATER MANAGEMENT REQUIREMENTS The proposed BMP shall meet or exceed the rules as defined in the NCDEQ Stormwater Design Manual Chapter A-1. Runoff Treatment and Volume Match and be designed to meet or exceed the Minimum Design Criteria (MDC) as outlined in Chapter C-0. The BMP chosen for these improvements is a Sand Filter as designed per Chapter C-6. These are the requirements this sand filter must meet per the rules of 15A NCAC 02H .1056: MDC for Sand Filters:     Objective: Remove urban stormwater pollutants including TSS, BOD, fecal coliform, hydrcarbons, and metals. Sand filters are designed to treat 0.75 times the design volume. Design Volume: The design storm depth for high density projects [greater than 24% Built Upon Area (BUA)] shall be 1-inch of storm water runoff from the BUA of the site. Discharge Flow: Stormwater outlets shall be designed so that they do not cause erosion downslope of the discharge point during the peak flow from the 10-year storm event as shown by engineering calculations. EXISTING SITE CONDITIONS The 14.54-acre parcel is currently being mass-graded as Project Infinity under approval from the State of North Carolina (Project ID: ROWAN-2018-007). The disturbed area is 12.89 acres. The project is bordered to the West and North by the Summit Park Drive 60’ R/W, to the South by undeveloped property in the Corporate Park owned by Rowan County, and to the East by industrial land owned by TKC XCI,LLC and a Church. There is an existing sanitary sewer easement along the eastern property line and an unnamed tributary to Town Creek east of that, which runs parallel and through the sewer easement. The site is located approximate 1.1 miles from Town Creek in the Yadkin Pee Dee River basin. The site’s existing contours had a ridge along approximately the middle of the site as it runs from south to north. The mass grading will drain the disturbed area to a sediment basin located along the western side of the site, in the location of the proposed BMP Sand Filter. The sand filter will discharge to an existing roadside ditch that drains to an existing yard inlet and piped to an existing culvert under Summit Park Drive. The pre-development conditions for runoff are a wooded site and approximately 7.2 acres draining to the discharge point of the BMP. The site is graded to be balanced and so it will not require the import nor export of material. The soils are 80% Helena Sandy Loam (HSG C) and 20% Armenia Loam (HSG C along the eastern property line, near the sewer easement). See the Maps & Figures section of this report for Drainage Area and Soils Maps.   Figure: Pre-development Drainage Area (HydroCAD Model)     PROPOSED SITE CONDITIONS The proposed improvements include the development of approximately 12.89 acres. The site will consist of a 100k SF industrial building with a 50k SF future building expansion. The building will have employee parking to the north which will include 170 parking spaces and an expandable truck court with future trailer parking on the west. This high impervious area gives the site a curve number (CN) of 91 with a drainage area to the sand filter of 10.77 acres. Sand filters are best used when the curve number is high, which was one of the reasons why it was chosen as the BMP for this site. Figure: Post Developed Drainage Area to BMP (HydroCAD Model)      PROPOSED SAND FILTER DESIGN The BMP for this site is a Sand Filter, designed per the rules of 15A NCAC 02H .1056: MDC for Sand Filters by NCDEQ. The sand filter is designed to treat the water quality volume from the 1-inch runoff over 1.77 acres congruently through the storm events. The Forebay of the sand filter has a 48”x48” concrete outlet structure which is designed so that the entire water quality volume will be treated through the sand filter and drained within 24 hours. Here is a detail of the outlets in the forebay, which control the water quality volume and discharge from the site: Figure: Details of discharge outlets from BMP forebay (HydroCAD Model)     There are two-10 ft wide riprap berms within the earthen dam separating the forebay from the sand filter, which allows the 1” runoff storm water volume to infiltrate the filter area at a controlled rate. Level spreaders evenly distribute the flow across the grassed area on the filter side to prevent erosion of the sand media. The BMP is designed to discharge at or below the 10-year, 6hr storm flow rate. The forebay and sand filter can detain a 50-Yr six hour storm with six inches of freeboard. CONCLUSIONS The requirements of the North Carolina Department of Environmental Quality (NCDEQ), the covenants of the Summit Corporate Center, and the ordinance of Rowan County are met in the proposed design.     MAPS & FIGURES HydroCAD Model Routing Diagram Drainage Area Maps NOAA Rainfall Data Location Map Soils Map USGS Map FEMA FIRM Map     HYDROCAD OUTPUT 1-inch Design Volume Storm Event D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 2HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 0S: PRE - DEVELOPMENT Runoff = 0.29 cfs @ 3.65 hrs, Volume= 0.037 af, Depth= 0.06" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25" Area (ac) CN Description 7.200 73.0 Woods, Fair, HSG C 7.200 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 12.2 200 0.0335 0.27 Sheet Flow, Range n= 0.130 P2= 3.32" 13.6 716 0.0310 0.88 Shallow Concentrated Flow, Woodland Kv= 5.0 fps 25.8 916 Total Subcatchment 0S: PRE - DEVELOPMENT Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)0.32 0.3 0.28 0.26 0.24 0.22 0.2 0.18 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25" Runoff Area=7.200 ac Runoff Volume=0.037 af Runoff Depth=0.06" Flow Length=916' Tc=25.8 min CN=73.0 0.29 cfs D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 3HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 1S: POST TO SAND FILTER [49] Hint: Tc<2dt may require smaller dt Runoff = 13.52 cfs @ 3.12 hrs, Volume= 0.487 af, Depth= 0.54" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25" Area (ac) CN Description 10.770 91.0 Urban industrial, 72% imp, HSG C 3.016 28.00% Pervious Area 7.754 72.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 1S: POST TO SAND FILTER Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25" Runoff Area=10.770 ac Runoff Volume=0.487 af Runoff Depth=0.54" Tc=5.0 min CN=91.0 13.52 cfs D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 4HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 2P: FOREBAY Inflow Area = 10.770 ac, 72.00% Impervious, Inflow Depth = 0.54" for 1" WQ event Inflow = 13.52 cfs @ 3.12 hrs, Volume= 0.487 af Outflow = 0.02 cfs @ 6.12 hrs, Volume= 0.113 af, Atten= 100%, Lag= 180.3 min Primary = 0.01 cfs @ 6.12 hrs, Volume= 0.001 af Secondary = 0.01 cfs @ 6.12 hrs, Volume= 0.111 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 767.73' @ 6.12 hrs Surf.Area= 17,506 sf Storage= 21,063 cf Plug-Flow detention time= 3,386.7 min calculated for 0.113 af (23% of inflow) Center-of-Mass det. time= 3,353.2 min ( 3,567.6 - 214.4 ) Volume Invert Avail.Storage Storage Description #1 766.00' 78,624 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 766.00 1,854 0 0 767.00 15,816 8,835 8,835 768.00 18,119 16,968 25,803 769.00 20,481 19,300 45,103 770.00 22,968 21,725 66,827 770.50 24,218 11,797 78,624 Device Routing Invert Outlet Devices #1 Primary 765.00'24.00" Round RCP_Round 24" L= 38.0' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 765.00' / 764.50' S= 0.0132 '/' Cc= 0.900 n= 0.012, Flow Area= 3.14 sf #2 Device 1 767.72'24.00" W x 4.00" H Vert. 10 YR. ORIFICE C= 0.600 #3 Device 1 769.60'48.00" x 48.00" Horiz. TOP OF OUTLET STRUCTURE C= 0.600 Limited to weir flow at low heads #4 Secondary 765.34'FLOW THROUGH RIPRAP BERM (Q=KIA) X 2.00 Head (feet) 0.00 1.00 2.00 3.00 4.00 5.00 Disch. (cfs) 0.000 0.003 0.005 0.008 0.011 0.013 Primary OutFlow Max=0.01 cfs @ 6.12 hrs HW=767.73' TW=0.00' (Dynamic Tailwater) 1=RCP_Round 24" (Passes 0.01 cfs of 19.92 cfs potential flow) 2=10 YR. ORIFICE (Orifice Controls 0.01 cfs @ 0.38 fps) 3=TOP OF OUTLET STRUCTURE ( Controls 0.00 cfs) Secondary OutFlow Max=0.01 cfs @ 6.12 hrs HW=767.73' TW=765.38' (Dynamic Tailwater) 4=FLOW THROUGH RIPRAP BERM (Q=KIA) (Custom Controls 0.01 cfs) D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 5HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Pond 2P: FOREBAY Inflow Outflow Primary Secondary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Inflow Area=10.770 ac Peak Elev=767.73' Storage=21,063 cf 13.52 cfs 0.02 cfs0.01 cfs0.01 cfs Pond 2P: FOREBAY Total Primary Secondary Stage-Discharge Discharge (cfs) 302520151050Elevation (feet)770 769 768 767 766 10 YR. ORIFICE TOP OF OUTLET STRUCTURE D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 6HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 3P: SAND FILTER [78] Warning: Submerged Pond 2P Secondary device # 4 by 0.75' Inflow = 0.01 cfs @ 6.12 hrs, Volume= 0.111 af Outflow = 0.01 cfs @ 89.12 hrs, Volume= 0.055 af, Atten= 10%, Lag= 4,979.8 min Primary = 0.01 cfs @ 89.12 hrs, Volume= 0.055 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 766.09' @ 89.12 hrs Surf.Area= 3,582 sf Storage= 2,484 cf Plug-Flow detention time= 3,560.7 min calculated for 0.055 af (49% of inflow) Center-of-Mass det. time= 1,774.8 min ( 5,382.9 - 3,608.0 ) Volume Invert Avail.Storage Storage Description #1 765.34' 22,648 cf SAND FILTER STORAGE (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 765.34 3,093 0 0 766.00 3,519 2,182 2,182 767.00 4,256 3,888 6,069 768.00 5,055 4,656 10,725 769.00 5,933 5,494 16,219 770.00 6,925 6,429 22,648 Device Routing Invert Outlet Devices #1 Primary 766.00'FILTER MEDIA Head (feet) 0.00 2.50 5.00 Disch. (cfs) 0.000 0.327 0.532 Primary OutFlow Max=0.01 cfs @ 89.12 hrs HW=766.09' TW=0.00' (Dynamic Tailwater) 1=FILTER MEDIA (Custom Controls 0.01 cfs) D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 7HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Pond 3P: SAND FILTER Inflow Primary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)0.013 0.012 0.011 0.01 0.009 0.008 0.007 0.006 0.005 0.004 0.003 0.002 0.001 0 Peak Elev=766.09' Storage=2,484 cf 0.01 cfs 0.01 cfs Pond 3P: SAND FILTER Primary Stage-Discharge Discharge (cfs) 0.50.450.40.350.30.250.20.150.10.050Elevation (feet)771 770 769 768 767 766 FILTER MEDIA D Charlotte 6-hr 1-Inch 1" WQ Rainfall=1.25"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 8HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 4P: TOTAL [40] Hint: Not Described (Outflow=Inflow) Inflow Area = 10.770 ac, 72.00% Impervious, Inflow Depth > 0.06" for 1" WQ event Inflow = 0.01 cfs @ 89.12 hrs, Volume= 0.056 af Primary = 0.01 cfs @ 89.12 hrs, Volume= 0.056 af, Atten= 0%, Lag= 0.0 min Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Pond 4P: TOTAL Inflow Primary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)0.012 0.011 0.011 0.01 0.01 0.009 0.009 0.008 0.008 0.007 0.007 0.006 0.006 0.005 0.005 0.004 0.004 0.003 0.003 0.002 0.002 0.001 0.001 0.000 0 Inflow Area=10.770 ac 0.01 cfs0.01 cfs     HYDROCAD OUTPUT 10-yr - 6-hour Storm Event D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 16HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 0S: PRE - DEVELOPMENT Runoff = 8.97 cfs @ 3.46 hrs, Volume= 0.668 af, Depth= 1.11" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40" Area (ac) CN Description 7.200 73.0 Woods, Fair, HSG C 7.200 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 12.2 200 0.0335 0.27 Sheet Flow, Range n= 0.130 P2= 3.32" 13.6 716 0.0310 0.88 Shallow Concentrated Flow, Woodland Kv= 5.0 fps 25.8 916 Total Subcatchment 0S: PRE - DEVELOPMENT Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)10 9 8 7 6 5 4 3 2 1 0 Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40" Runoff Area=7.200 ac Runoff Volume=0.668 af Runoff Depth=1.11" Flow Length=916' Tc=25.8 min CN=73.0 8.97 cfs D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 17HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 1S: POST TO SAND FILTER [49] Hint: Tc<2dt may require smaller dt Runoff = 51.11 cfs @ 3.15 hrs, Volume= 2.196 af, Depth= 2.45" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40" Area (ac) CN Description 10.770 91.0 Urban industrial, 72% imp, HSG C 3.016 28.00% Pervious Area 7.754 72.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 1S: POST TO SAND FILTER Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)55 50 45 40 35 30 25 20 15 10 5 0 Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40" Runoff Area=10.770 ac Runoff Volume=2.196 af Runoff Depth=2.45" Tc=5.0 min CN=91.0 51.11 cfs D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 18HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 2P: FOREBAY Inflow Area = 10.770 ac, 72.00% Impervious, Inflow Depth = 2.45" for 10yr-6hr event Inflow = 51.11 cfs @ 3.15 hrs, Volume= 2.196 af Outflow = 8.77 cfs @ 3.58 hrs, Volume= 1.813 af, Atten= 83%, Lag= 26.0 min Primary = 8.74 cfs @ 3.58 hrs, Volume= 1.696 af Secondary = 0.02 cfs @ 3.58 hrs, Volume= 0.117 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 769.79' @ 3.58 hrs Surf.Area= 22,445 sf Storage= 62,048 cf Plug-Flow detention time= 341.8 min calculated for 1.813 af (83% of inflow) Center-of-Mass det. time= 324.9 min ( 531.1 - 206.1 ) Volume Invert Avail.Storage Storage Description #1 766.00' 78,624 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 766.00 1,854 0 0 767.00 15,816 8,835 8,835 768.00 18,119 16,968 25,803 769.00 20,481 19,300 45,103 770.00 22,968 21,725 66,827 770.50 24,218 11,797 78,624 Device Routing Invert Outlet Devices #1 Primary 765.00'24.00" Round RCP_Round 24" L= 38.0' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 765.00' / 764.50' S= 0.0132 '/' Cc= 0.900 n= 0.012, Flow Area= 3.14 sf #2 Device 1 767.72'24.00" W x 4.00" H Vert. 10 YR. ORIFICE C= 0.600 #3 Device 1 769.60'48.00" x 48.00" Horiz. TOP OF OUTLET STRUCTURE C= 0.600 Limited to weir flow at low heads #4 Secondary 765.34'FLOW THROUGH RIPRAP BERM (Q=KIA) X 2.00 Head (feet) 0.00 1.00 2.00 3.00 4.00 5.00 Disch. (cfs) 0.000 0.003 0.005 0.008 0.011 0.013 Primary OutFlow Max=8.70 cfs @ 3.58 hrs HW=769.79' TW=0.00' (Dynamic Tailwater) 1=RCP_Round 24" (Passes 8.70 cfs of 29.44 cfs potential flow) 2=10 YR. ORIFICE (Orifice Controls 4.43 cfs @ 6.64 fps) 3=TOP OF OUTLET STRUCTURE (Weir Controls 4.28 cfs @ 1.42 fps) Secondary OutFlow Max=0.02 cfs @ 3.58 hrs HW=769.79' TW=765.37' (Dynamic Tailwater) 4=FLOW THROUGH RIPRAP BERM (Q=KIA) (Custom Controls 0.02 cfs) D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 19HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Pond 2P: FOREBAY Inflow Outflow Primary Secondary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)55 50 45 40 35 30 25 20 15 10 5 0 Inflow Area=10.770 ac Peak Elev=769.79' Storage=62,048 cf 51.11 cfs 8.77 cfs8.74 cfs 0.02 cfs Pond 2P: FOREBAY Total Primary Secondary Stage-Discharge Discharge (cfs) 302520151050Elevation (feet)770 769 768 767 766 10 YR. ORIFICE TOP OF OUTLET STRUCTURE D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 20HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 3P: SAND FILTER [78] Warning: Submerged Pond 2P Secondary device # 4 by 0.75' Inflow = 0.02 cfs @ 3.58 hrs, Volume= 0.117 af Outflow = 0.01 cfs @ 84.11 hrs, Volume= 0.060 af, Atten= 52%, Lag= 4,831.6 min Primary = 0.01 cfs @ 84.11 hrs, Volume= 0.060 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 766.09' @ 84.11 hrs Surf.Area= 3,583 sf Storage= 2,490 cf Plug-Flow detention time= 3,499.1 min calculated for 0.060 af (51% of inflow) Center-of-Mass det. time= 1,743.5 min ( 5,229.8 - 3,486.3 ) Volume Invert Avail.Storage Storage Description #1 765.34' 22,648 cf SAND FILTER STORAGE (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 765.34 3,093 0 0 766.00 3,519 2,182 2,182 767.00 4,256 3,888 6,069 768.00 5,055 4,656 10,725 769.00 5,933 5,494 16,219 770.00 6,925 6,429 22,648 Device Routing Invert Outlet Devices #1 Primary 766.00'FILTER MEDIA Head (feet) 0.00 2.50 5.00 Disch. (cfs) 0.000 0.327 0.532 Primary OutFlow Max=0.01 cfs @ 84.11 hrs HW=766.09' TW=0.00' (Dynamic Tailwater) 1=FILTER MEDIA (Custom Controls 0.01 cfs) D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 21HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Pond 3P: SAND FILTER Inflow Primary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)0.026 0.024 0.022 0.02 0.018 0.016 0.014 0.012 0.01 0.008 0.006 0.004 0.002 0 Peak Elev=766.09' Storage=2,490 cf 0.02 cfs 0.01 cfs Pond 3P: SAND FILTER Primary Stage-Discharge Discharge (cfs) 0.50.450.40.350.30.250.20.150.10.050Elevation (feet)771 770 769 768 767 766 FILTER MEDIA D Charlotte 6-hr 10-yr 10yr-6hr Rainfall=3.40"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 22HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 4P: TOTAL [40] Hint: Not Described (Outflow=Inflow) Inflow Area = 10.770 ac, 72.00% Impervious, Inflow Depth > 1.96" for 10yr-6hr event Inflow = 8.74 cfs @ 3.58 hrs, Volume= 1.756 af Primary = 8.74 cfs @ 3.58 hrs, Volume= 1.756 af, Atten= 0%, Lag= 0.0 min Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Pond 4P: TOTAL Inflow Primary Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)9 8 7 6 5 4 3 2 1 0 Inflow Area=10.770 ac 8.74 cfs8.74 cfs     HYDROCAD OUTPUT 50-yr - 6-hour Storm Event D Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 23HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 0S: PRE - DEVELOPMENT Runoff = 15.22 cfs @ 3.41 hrs, Volume= 1.128 af, Depth= 1.88" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48" Area (ac) CN Description 7.200 73.0 Woods, Fair, HSG C 7.200 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 12.2 200 0.0335 0.27 Sheet Flow, Range n= 0.130 P2= 3.32" 13.6 716 0.0310 0.88 Shallow Concentrated Flow, Woodland Kv= 5.0 fps 25.8 916 Total Subcatchment 0S: PRE - DEVELOPMENT Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48" Runoff Area=7.200 ac Runoff Volume=1.128 af Runoff Depth=1.88" Flow Length=916' Tc=25.8 min CN=73.0 15.22 cfs D Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 24HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Subcatchment 1S: POST TO SAND FILTER [49] Hint: Tc<2dt may require smaller dt Runoff = 69.28 cfs @ 3.10 hrs, Volume= 3.122 af, Depth= 3.48" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48" Area (ac) CN Description 10.770 91.0 Urban industrial, 72% imp, HSG C 3.016 28.00% Pervious Area 7.754 72.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 1S: POST TO SAND FILTER Runoff Hydrograph Time (hours) 12011511010510095908580757065605550454035302520151050Flow (cfs)75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48" Runoff Area=10.770 ac Runoff Volume=3.122 af Runoff Depth=3.48" Tc=5.0 min CN=91.0 69.28 cfs D Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 25HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 2P: FOREBAY Inflow Area = 10.770 ac, 72.00% Impervious, Inflow Depth = 3.48" for 50yr-6hr event Inflow = 69.28 cfs @ 3.10 hrs, Volume= 3.122 af Outflow = 30.22 cfs @ 3.27 hrs, Volume= 2.739 af, Atten= 56%, Lag= 10.0 min Primary = 30.19 cfs @ 3.27 hrs, Volume= 2.621 af Secondary = 0.03 cfs @ 3.27 hrs, Volume= 0.118 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 770.22' @ 3.27 hrs Surf.Area= 23,509 sf Storage= 71,856 cf Plug-Flow detention time= 240.4 min calculated for 2.738 af (88% of inflow) Center-of-Mass det. time= 229.2 min ( 431.0 - 201.8 ) Volume Invert Avail.Storage Storage Description #1 766.00' 78,624 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 766.00 1,854 0 0 767.00 15,816 8,835 8,835 768.00 18,119 16,968 25,803 769.00 20,481 19,300 45,103 770.00 22,968 21,725 66,827 770.50 24,218 11,797 78,624 Device Routing Invert Outlet Devices #1 Primary 765.00'24.00" Round RCP_Round 24" L= 38.0' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 765.00' / 764.50' S= 0.0132 '/' Cc= 0.900 n= 0.012, Flow Area= 3.14 sf #2 Device 1 767.72'24.00" W x 4.00" H Vert. 10 YR. ORIFICE C= 0.600 #3 Device 1 769.60'48.00" x 48.00" Horiz. TOP OF OUTLET STRUCTURE C= 0.600 Limited to weir flow at low heads #4 Secondary 765.34'FLOW THROUGH RIPRAP BERM (Q=KIA) X 2.00 Head (feet) 0.00 1.00 2.00 3.00 4.00 5.00 Disch. (cfs) 0.000 0.003 0.005 0.008 0.011 0.013 Primary OutFlow Max=29.52 cfs @ 3.27 hrs HW=770.21' TW=0.00' (Dynamic Tailwater) 1=RCP_Round 24" (Passes 29.52 cfs of 31.02 cfs potential flow) 2=10 YR. ORIFICE (Orifice Controls 4.89 cfs @ 7.33 fps) 3=TOP OF OUTLET STRUCTURE (Weir Controls 24.63 cfs @ 2.54 fps) Secondary OutFlow Max=0.03 cfs @ 3.27 hrs HW=770.21' TW=765.36' (Dynamic Tailwater) 4=FLOW THROUGH RIPRAP BERM (Q=KIA) (Custom Controls 0.03 cfs) D Charlotte 6-hr 50-yr 50yr-6hr Rainfall=4.48"Infinity Sand Filter Printed 2/28/2018Prepared by Burton Engineering Page 27HydroCAD® 10.00-17 s/n 03513 © 2016 HydroCAD Software Solutions LLC Summary for Pond 3P: SAND FILTER [78] Warning: Submerged Pond 2P Secondary device # 4 by 0.75' Inflow = 0.03 cfs @ 3.27 hrs, Volume= 0.118 af Outflow = 0.01 cfs @ 83.25 hrs, Volume= 0.061 af, Atten= 55%, Lag= 4,798.8 min Primary = 0.01 cfs @ 83.25 hrs, Volume= 0.061 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-120.00 hrs, dt= 0.05 hrs Peak Elev= 766.09' @ 83.25 hrs Surf.Area= 3,583 sf Storage= 2,490 cf Plug-Flow detention time= 3,492.6 min calculated for 0.061 af (52% of inflow) Center-of-Mass det. time= 1,740.0 min ( 5,203.6 - 3,463.6 ) Volume Invert Avail.Storage Storage Description #1 765.34' 22,648 cf SAND FILTER STORAGE (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic-feet) (cubic-feet) 765.34 3,093 0 0 766.00 3,519 2,182 2,182 767.00 4,256 3,888 6,069 768.00 5,055 4,656 10,725 769.00 5,933 5,494 16,219 770.00 6,925 6,429 22,648 Device Routing Invert Outlet Devices #1 Primary 766.00'FILTER MEDIA Head (feet) 0.00 2.50 5.00 Disch. (cfs) 0.000 0.327 0.532 Primary OutFlow Max=0.01 cfs @ 83.25 hrs HW=766.09' TW=0.00' (Dynamic Tailwater) 1=FILTER MEDIA (Custom Controls 0.01 cfs)     STORM WATER HYDRAULIC CALCULATIONS Storm Sewers Design