HomeMy WebLinkAboutSW3170201 - Oaks at Camden North Phase (2)Kevin E. Herring ENGINEERING 16101 SILVER ROAD OAKBORO NC 28129, 980-621-0935 Date: 7/11/17 To: NCDEQ Energy, Mineral, Et Land Resources Stormwater Permitting-Attn Mike Randall 1612 Mail Service Center Raleigh NC 27699-1612 Transmittal Project / Description: Oaks at Camden North Phase -Piney Dr. Ext Ref - SW3170201 (Modification) Unionville NC (DEQ Jurisdiction) Stormwater Permit Enclosed: 1 - Original Et 1 copy of Application (Modification due to expansion Et additional lots) 1 - Original Et 1 copy of Deed Restrictions (revised - to replace previous submittal) 1 - Low Density Supplement (updated for additional ditiches) 2 - Sets of revised SWMP plan for North Phase showing Piney Dr. stub (dated 6/23/17) 2 - Sets of full plans for Piney Dr. Extension 1 - Copies of Calculations 1 - Copy of Deed 1 - Copy of USGS 1 - Review Fee ($505) ❑X For Review / Comments FIFor Approval FIResubmittal JUL 312017 DENR-LAND QUALITY STORMWATER PERMITTING Remarks: Approved project currently beginning construction. No lots have been recorded yet. Developer purchased adjoining property. Revised SWMP plan reflects Piney Drive Stub to be constructed now. New modification submittal includes full plan set, calcs, updated Deed Restrictions for all lots, Low Density SupL, Et fee for adjoining property (future Piney Dr. extension) Please contact me if you have any questions or additional information is needed. Note change in email below. SIGNED: \\ ACCEPTED: PLEASE CONTACT ME AT 980-621-0935 OR kevin@kevinherrinRengineerin .com CONCERNING THIS PROJECT. JUL 31 2017 FILED UNION COUNTY, NC CRYSTAL CRUMP REGISTER OF DEEDS DENR-LAND QUAUTX FILED Aug 29, 2016 STORMIWTER RERMITTING AT 04:24 pm BOOK 06756 START PAGE 0390 END PAGE 0393 INSTRUMENT # 26262 EXCISE TAX $316.00 AH NORTH CAROLINA GENERAL WARRANTY DEED Excise Tax: Q& Parcel Identifier No. 09072008A02 Verified by County on the day of , 20 By: Mail/Box to: RUSSELL Z. ASTI This instrument was prepared by: Russell Z. Asti Brief description for the Index: 19.69 ACRES OLD CAMDEN ROAD THIS DEED made this 24 day of AUGUST. 2016, by and between GRANTOR GRANTEE TRACEY G. AAMMAREN AND HUSBAND, CAMDEN OAKS, LLC GREG M. TLAMMARFN MAILING ADDRESS: CHRISTOPHER BARRY GRIFFIN AND WIFE, 3615 LAKE TWITTY DR. JENNIFER C. YEARICK MONROE, NC 28110 Enter in appropriate block for each party: name, address, and, if appropriate, character of entity, e.g. corporation or partnership. The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and shall include singular, plural, masculine, feminine or neuter as required by context. WITNESSETH, that the Grantor, for a valuable consideration paid by the Grantee, the receipt ofwhich is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee in fee simple, all that certain lot or parcel of land situated in the City of MONROE, _ Township, UNION County, North Carolina and more particularly described as follows: SEE EXHIBIT "A" The property hereinabove described was acquired by Grantor by instrument recorded in Book 6709, page 531. A map showing the above described property is recorded in Plat _ Book TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple. And the Grantor covenants with the Grantee, that Grantor is seized of the premises in fee simple, has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever, other than the following exceptions: NC Bar Association Form No. 3 © 1976, Revised © 1977, 2002 Printed by Agreement with the NC Bar Association —1981 - Chicago Title Insurance Company 6 (SEAL) CHRISTOPHER BARRY GRIFFIN SEAL-�,TA W State of &XIML'Vl'` "County of I, the undersigned Notary Public of the County and -State aforesaid, certify that CHRISTOPHER BARRY GRIFFIN AND WIFE, JENNIFER C. YEARICK personally appeared before me this day and acknowledged CO , ` �; `•��/ire due execution ofe foregoing insVWent for e purposes the} m expr §2d. WW,' y hand and Notarial _ r famp or seal this day of �.� - , -2-071 • �..j 1�1y Co sio Expires: (? 2 �-6 l Notary Public s' 7 j NC Bar Association Form No. 3 © 1976, Revised © 1977, 2002 Printed-byAgreement with the NC Bar Association —1981 - Chicago Title Insurance Company -- - IN-WnNESS WEM E®]F, tine i"rraiator has duly executed the foregoing as of the day *dyeaieArss above written. TRACEY (SEAL) GREG N SEAL-STAAD State of ,�2����'; — Comity of al JG � E, the undersigned Notary Public of the County and State oresaid, certify tba# TRACEY (g_ NAIvE1yEA12EN AND HUSBAND, GREGr M. E%1bWARWpersonally beforemethis day and aclmowledgedthe due execution ofthe foregoing instmment £orthe purposes therein expressed. Witness nay hand and Notarial stamp or seal this .2- day of ,&- ,20 / . My Commission Mxpires: - Z NoWy Public RA ib3 r 7,%, t r,-, A,. �" f CC(S:SZZ,.,;..%.`i SEE NM P 4G E FOR AIDDMONAad SIGNATURES NC Bar Association Foran No. 3 O 1976, Revised 0 1977, 2002 Printe4 by Agreemaut with the NC Bar Association — 1981 - Chicago 'title Insurance Company BEGINNING at a point in the centerline of Old Camden Road (State Road 1681, a 60 foot right of way) said point being the southwest corner or on the line of the Timothy M Saunders property (6669/870 UCR) said point also being located N. 69-00-02 E. 20.16 feet from a rebar (found) and running thence from said BEGINNING with the line of the said Saunders property three calls as follows: (1) N. 69-00-02 E. 33.87 feet to an old iron (found); (2) N. 81-56-18 E. 350.16 feet to a rebar (found) and (3) N. 26-55-15 W., passing a rebar (found) at 470.19 feet for a total of 714.24 feet to a rebar (found) on the line of the Billy F. Simpson property (235/10 UCR) and running thence with the Billy F. Simpson line two calls as follows: (1) N. 73-15- 56 E. 42.41 feet to a flat iron (found) and (2) N. 24-56-52 W. 203.90 feet to an old Iron (found)thence continuing with this call with the line of the Carl Haigler, Trustee property (1534/655 UCR) and the line of the Ronnie E. Haigler property (5146/766 UCR) N. 24-56-52 W. 418.95 feet to a #5 rebar (found) on the line of the Catherine L. Parker property (1856/514 UCR); running thence with the said Parker line N. 73- 59-07 E. 756.92 feet to a 2 inch iron pipe (found), a corner of the Samuel D. and Vickey S. Pressley property (1735/574 UCR) running thence with said Pressley line S. 20-42-09 E. 854. 48 feet to an old axle (found) on the line of the Camden Oaks, LLC property (6118/771 UCR) running thence with the lines of the said Camden Oaks, LLC property four calls as follows: (1) S. 73-02-07 W. 495.71 feet to a one inch round bar (found) (2) S. 25-03-30 E. 365.81 feet to a 1 inch rebar (found) (3) S. 46-23-50 E. 227.74 feet to a #5 rebar (found) and (4) S. 55-09-09 W. 615.17 to a point in the center of Old Camden Road; thence with the center of Old Camden Road four calls as follows: N. (1) N 34-36-24 W. 189.51 feet; (2) N. 34-13-53 W. 74.59; (3) N. 33-17-35 W. 56.37 feet and (4) N. 32-49-46 W. 41.98 feet to the point and place of the BEGINNING and containing 20.01 acres all according to a survey by Jeffery S. Gordon, PLS dated April 15, 2016. Low Density Residential Subdivisions Deed Restrictions & Protective Covenances In accordance with Title 15 NCAC 2H.1000 and S.L. 2006-246, the Stormwater Management Regulations, deed restrictions and protective covenants are required for Low Density Residential Subdivisions where lots will be subdivided and sold. Deed restrictions and protective covenants are necessary to ensure that the development maintains a "built -upon" area consistent with the applicable regulation governing the density level. I, Ron Rushing acknowledge and affirm by my signature below, that i will cause the following deed restrictions and protective covenants to be recorded for Oaks at Camden North Phase prior to the sale of any lot: 1. The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number , as issued by the Division of Energy, Mineral and Land Resources under the Stormwater Management Regulations. 2. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the stormwater management permit. 3. These covenants are to run with the land and be binding on all persons and parties claiming under them. 4. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Energy, Mineral and Land Resources. 5. Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Energy, Mineral and Land Resources. 6. The maximum allowable built -upon area per lot is_ 13,712 square feet. This allotted amount includes any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, and coquina, but does not include raised, open wood decking, or the water surface of swimming pools. 7. In the case of a lot within CAMA's regulated AEC, where the Division of Coastal Management calculates a different maximum allowable built -upon area for that lot than is shown herein, the governing maximum built -upon area for that lot shall be the most restrictive of the two. 8. Filling in or piping of any vegetative conveyances (ditches, swa/es, etc.) associated with the development except for average driveway crossings is strictly prohibited by any persons. 9. Each lot will maintain a 30* foot wide vegetated buffer between all impervious areas and surface waters. 10. All roof drains shall terminate at least 30* foot from the mean high water mark of surface waters. *50 foot for proyec cated in the 20 coastal counties. Signature: Date: 7— 13 - 2- O 17 I, Adam K, , a Notary Public in the State of iVffiG'l f , County of d f,0M do hereby certify that - 1' 1 �''�personally appeared before me this the 13 day of �Tj 114 20 1 and acknowledge the due execution of the foregoing instrument. Witness my hand and official sg(�aaA�►^,,,h i%OTARYSignature My Commission Expires March 3, 2021 = PUBLIC My Commission expires el, Form DRPC-5 Rev.2 05Nov2009 Page 1 of 1 r LIMITED LIABILITY COMPANY ANNUAL NAME OF LIMITED LIABILITY COMPANY: Camden Oaks, L.L.0 SECRETARY OF STATE ID NUMBER: 1318024 REPORT FOR THE YEAR: 2017 SECTION A: REGISTERED AGENT'S INFORMATION 1. NAME OF REGISTERED AGENT: Jerry Brent Collins 2. SIGNATURE OF THE NEW REGISTERED AGENT: STATE OF FORMATION: NC SOSID: 1318024 Date Filed: 2/21/201711:59:00 PM Elaine F. Marshall North Carolina Secretary of State CA2017 052 03333 ------------ SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT 3. REGISTERED OFFICE STREET ADDRESS & COUNTY 4. REGISTERED OFFICE MAILING ADDRESS 3615 Lake Twitty Dr 3615 Lake Twitty Dr Monroe, NC 28110-9311 Union Monroe, NC 28110-9311 Union SECTION B: PRINCIPAL OFFICE INFORMATIety 1. DESCRIPTION OF NATURE OF BUSINESS: Real Estate Development 2. PRINCIPAL OFFICE PHONE NUMBER: (704) 534-9966 3. PRINCIPAL OFFICE EMAJ Privacy Redaction 4. PRINCIPAL.OFFICE STREET ADDRESS& COUNTY - - S. PRINCIPAL OFFICE MAILING ADDRESS '•- 3615 Lake Twitty Dr o. Monroe, NC 28110-9311 Union 3615 Lake Twitty Dr Monroe, NC 28110-9311 Uniori SECTION C: COMPANY OFFICIALS (Enter additional Company Officials in Section E.) NAME: Jerry Brent Collins NAME: J & M Investments LLC TITLE: Member ADDRESS: 1123 11 111111i,ticle Lake Drive Monroe, NC 28110 Union TITLE: Member ADDRESS: 6205 Kate Rd Monroe, NC 28110-9402 Union NAME: Ron R Rushing TITLE: General Manager ADDRESS: 3615 Lake Twitty Drive Monroe, NC 28110 SECTION D: CERTIFIC N O U L R PO T. Section D must be completed in its entirety by a person/business entity. IGNATURE Form must be sign y om DATE pony aal rested under Section C of this form. Ron R. Rushing General Manager Print or Type Name of Company Official Print or Type The Title of the Company Official SUBMIT THIS ANNUAL REPORT WITH THE REQUIRED FILING FEE OF $200 a a MAIL TO: Secretary of State, Corporations Division, Post Office Box 29525. Raleigh, NC 27626-0525 SECTION E: ADDITIONAL COMPANY OFFICIALS NAME: Tom Williams NAME: TITLE: Member TITLE: ADDRESS: ADDRESS: 3205 Chancellor Drive Monroe, NC 28110-9311 NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: NAME: NAME: TITLE: TITLE: TITLE: ADDRESS: ADDRESS: ADDRESS: NAME: NAME: Name: TITLE: TITLE: TITLE: ADDRESS: ADDRESS: ADDRESS: NAME: NAME: NAME: TITLE: TITLE: TITLE: ADDRESS: ADDRESS: __ ADDRESS: s OAKS AT CAMDEN (NORTH PHASE) PINEY DRIVE EXTENSION Unionville NC STORMWATER MANAGEMENT CALCULATIONS W.m Ron Rushing Camden Oaks LLC Kevin E. Herring PE 16101 Silver Road Oakboro NC 28129 (980) 621-0935 RECEIVED JUL31 2017 DEIVR-LAND I, QU�17W, STGIRM>rV . TIER, PBRjtli MLq STORMWATER NARRATIVE The North Phase Low Density Stormwater Permit (SW3170201) was approved on March 6,2017. The North Phase was proposed for 43 lots with a total area of 67.15 acres. Site is currently under construction, however, the developer has acquired the adjacent property and proposes to add 15 lots for a total of 58 lots. The approved Stormwater Permit is proposed to be modified to include an additional 872,886 sf (20.04 acres) or a total area of 87.19 acres. This includes all area in proposed lots and all existing and proposed NCDOT right of way. The site is located off SR 1681 (Old Camden Road) approximately 3,300 feet north of SR 1006 (Olive Branch Road). The site is in the Yadkin River Basin and drains to Richardson Creek. The site is in the Town of Unionville. The site is not in a Watershed Water Supply basin. The development as modified is proposed as "low density" with a maximum built upon area of 24%. The street cross-sections are shoulder and ditch. This combined with natural swales leaving the site shall provide the required conveyances. The maximum built upon area per lot as modified for the additional 20.04 acres shall not exceed 13,712 sf for all 58 lots. Job: Oaks at Camden North Phase (w! Piney Dr) Job No. Date 7/7/2017 Sheet Subject: BUA Breakdown of Driveways in RMI By KEH Chk By BUA Breakdown Site Area = 2,925,054sf (N. Phase) + 872,886 (Piney Dr. Ext) = 3,797,940sf = 87.19ac Roadway area including pull off for Cluster mailbox locations = 73,650 (N. Phase) + 25118 (Piney Dr)=98,768 sf veways in rvvv Length Width 13.5 12 15.0 12 21.0 12 Total # of Lots Total Lots 38 6156 57-68, 73-79, 81-82,88-89, 95-96, 100-112 14 2520 69-72,83-87,90-94 6 1512 80, 97-99,113-114 58 10188 :xisting Imp 'hree areas where Site property line goes to centerline of Old Camden Rd. At McCollum Oaks Dr, along Lot 114, and in front of Lots 98 & 99 (6,781 sf total). )ther Area ;oncrete pads at Cluster Mailbox location. (90sf total). Proposed Impervious for Lots = 795,296 sf (13,712sf * 58 Lots) Total Impervious = 911,123 sf (795,296 + 98,768 + 10,188 + 6,781 + 90) Density = 23.99% (911,123 / 3,797,940) Job Name Subject Camden Oaks -Piney Rd Ext Job No. DIVERSION CHANNEL SUMMARY SHEET Date 717/2017 By KEH Sheet Chk By Diversion Channel Drainage Area Ac Average Slope (%) Bottom Width ft) Side Slope ft/ft Flow Depth (ft DesignTop De (ft Width T Uft Temporary Liner RD -1.0% 1.90 1.00 0.50 3 0.99 1.50 9.50 STRAW WITH NET RD -1.5% 0.30 1.50 0.50 3 0.44 1.00 6.50 STRAW WITH NET PD -3 3.00 2.00 1 1.00 3 0.96 1.50 10.00 STRAW WITH NET STRAW WITH NET" TO BE NAG S-75 OR EQUAL, STAPLE PATTERN "A" Job Name Camden Oaks -Piney Rd Ext Job No. Date 7/7/2017 Sheet Subject ROADSIDE DITCHES By KEH Chk By DETERMINE TEMPORARY LINER APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Velocity is checked to see if Temporary Liner is required. If required, 2 year storm is used for design. Shear Stress is then compared to Permissable Shear Stress allowed. PROPOSED CHANNEL: RD -1.0% DRAINAGE AREA: 1.90 MAX SHEAR Td allowed: 1.45 AVERAGE SLOPE: 1.00 % VELOCITY CHECK of Channel Design using Manning of 0.02 (Bare Earth) Calculated VELOCITY of 3.86 is GREATER THAN 2 Feet per second TEMPORARY LINER REQUIRED (USING 2 YEAR STORM FOR DESIGN) PROPOSED LINER: STRAW WITH NET *MANNINGS (n) of 0.033 used for design DISCHARGE** DEPTH VELOCITY Calculated Shear Q cfs d ft v f/s d 5.66 0.79 2.49 0.49 Calculated shear of 0.49 is less than the Permissable Shear*** of 1.45 Therefore STRAW WITH NET can be used as a temporary liner for RD -1.0% *Mannings Coefficient obtained from Table 8.05e **RATIONAL METHOD USED TO DETERMINE DISCHARGE Q --CIA Where C= 0.5 Y= 7.63 in/hr for channel design,Tc= 5.0 i min L= 5.96 in/hr for 2 year storm REF. NOAA Atlas 14 Data —Permissable Shear Stress Td obtained from Table 8.059 ** Td=yds Where T=Shear Stress(lb/sq ft), y=unit wt of water, (62.4lb/cubic ft), d --flow depth(ft), s=siope(ft/ft) Tables From the IVC Erosion & Sediment Control Manual (unless otherwise noted) Job Name Camden Oaks-Pir Subject ROADSIDE DITCI DETERMINE GRASS LINER PROPOSED GRASS LINER: Use Retardence Class D Rd Ext Job No. Date 7/7/2017 Sheet By ICSH Chk Sy TALLIFESCUE APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL: RD -1.0% AVERAGE SLOPE: 1.00 % MAX VELOCITY allowed: 5.50 feet/sec MANNING'S (n) used: 0.045 MAX VR allowed: 2.2 - �DISGHARG�= "=FCO1N.�'_.•��_• : WE1nTEjC?` •,�t.,.�;,, F - -GIA:;'°<:, ��:;X=ARPA`� - 'PERIMETER_ R, ;Sid Sfo a Bottom , VELOCITY . ;,Q :,. -s" 'x�ft J 1Nr tti .( � ' 1.00 3 0.5 2.10 7.25 3.45 6.77 0.73 0.51 1.07 FLOW IS SUBCRITICAL VELOCITY CHECK Calculated velocity of VR CHECK Calculated VR 2.10 feet/sec is less than permissable velocity of 1.07 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a,grass liner for RD -1.0% `Permissable Velocity Obtained from Table 8.05a -VR = Velocity Q Hydraulic Radius = Velocity 4 Flow Area/Wetted Perimeter Tables From the NC Erosion & Sediment Control Manual (unless otherwise noted) 2.2 5.50 feettsec Job Name Camden Oaks -Piney Rd Ext Job No. Date 7/7!2017 Sheet Subject ROADSIDE DITCHES By KEEH Chk By DETERMINE TEMPORARY LINER APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Velocity is checked to see if Temporary Liner is required. if required, 2 year storm is used for design. Shear Stress is then compared to Permissable Shear Stress allowed. PROPOSED CHANNEL: RD -1.5% DRAINAGE AREA: 0.30 Acres MAX SHEAR Td allowed: 1.45 AVERAGE SLOPE: 1.50 % VELOCITY CHECK of Channel. Design using Manning of 0.02 (Bare Earth) Calculated VELOCITY of 2.81 is GREATER THAN 2 Feet per second TEMPORARY LINER REQUIRED (USING 2 YEAR STORM FOR DESIGN) PROPOSED LINER: STRAW WITH NET *MANNINGS (n) of 0.065 used for design DISCHARGE** DEPTH VELOCITY Calculated Shear Q cfs d ft v (f1s) (Td — 0.89 0.44 1.10 0.42 Calculated shear of 0.42 is less than the Permissable Shear*** of 1.45 Therefore STRAW WITH NET can be used as a temporary liner for RD -1.5% 'Mannings Coefficient obtained from Table 8.05e **RATIONAL METHOD USED TO DETERMINE DISCHARGE Q=CIA Where C= 0.5 1= 7.63 in/hr for channel design,Tc= 5 min 1= 5.96 in/hr for 2 year storm REF. NOAA Atlas 14 Data *`*Permissable Shear Stress Td obtained from Table 8.058 *** Td=yds Where T --,Shear Stress(lb/sq ft), y --unit wt of water, (62.4lb/cubic ft), d --flow depth(ft), s=slope(ft/ft) Tables From the AIC Erosion & Sediment Control Manual (unless otherrnrdse noted) Job Dame Camden Oaks -Piney Rd Ext Job No. Date 7/7/2017 Sheet Subject ROADSIDE DITCHES By KEH Chk By DETERMINE GLASS LINER PROPOSED GRASS LINER: TALL FESCUE Use Retardence Class D APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL: RD -1.5% AVERAGE SLOPE: 1.50 % MAX VELOCITY allowed: 5.50 feet/sec MANNING'S (n) used: 0.045 MAX VR allowed: 2.2 ;DISCHARGE,,' - FLOW'.°..r'==T .UVETiEE�r =`_ ,:GRiTICAC.`_',`. - - - a- ! 'P RIM DEPTH, R®4J l�tyli`Y• • Q -CIA:': :AREA„ E E'TERs{, rv', e'S10"�." ,:;SO,tfOFn,,'r„ ,11EI- ;.5;•- gx,. _r.�. --":v', a" cfs '-(dj.t4'-�`uv►atii 1�11"frsj.='� _ �a`t 0.43 3 0.5 1.54 1.14 0.74 3.17 0.31 0.55 0.36 FLOW IS SUl3CRITICAL VELOCITY CHECK Calculated velocity of VR CHECK Calculated VR 1.54 feet/sec is less than permissable velocity of 0.36 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a grass liner for RD -1.5% `Permissible Velocity Obtained from Table 8.05a **VR = Velocity * Hydraulic Radius = Velocity' 171my Area/Wetted Perimeter Tables From the NC Erosion & Sediment Control Manual (unless otherwise noted) 2.2 5.50 feet/sec Job Name Camden Oaks -Piney Rd Ext Subject PERMANENT DITCHES DETERMINE TEMPORARY LINER Job No. Date 7/7/2017 Sheet By KEH Choc By APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Velocity is checked to see if Temporary Liner is required. If required, 2 year storm is used for design. Shear Stress is then compared to Permissable Shear Stress allowed. PROPOSED CHANNEL: PD -3 DRAINAGE AREA: 3.00 Acres MAX SHEAR Td allowed: 1.45 AVERAGE SLOPE: 2.00 % VELOCITY CHECK of Channel Design using Manning of 0.02 (Bare Earth) Calculated VELOCITY of 5.59 is GREATER THAN 2 Feet per second TEMPORARY LINER REQUIRED (USING 2 YEAR STORM FOR DESIGN) PROPOSED LINER: STRAW WITH NET *MANNINGS (n) of 0.033 used for design DISCHARGE" DEPTH VELOCITY Calculated Shear Q cfs d (ft) v (fis) (Td — 8.94 0.76 3.61 0.94 Calculated shear of 0.94 is less than the Permissabie Shear** of 1.45 Therefore STRAW WITH NET can be used as a temporary liner for PD -3 "Mannings Coefficient obtained from Table 8.05e -RATIONAL METHOD USED TO DETERMINE DISCHARGE Q=CIA Where C= 0.5 t= 7.63 in/hr for channel design,Tc= 5 min in 5.96 in/hr for 2 year storm REF: NOAA Atlas 14 Data —permissable Shear Stress Td obtained from Table 8.059 --Td=yds Where T=Shear Stress(lb/sq ft), y --unit wt of water, (62.4lb/cubic ft), d --flow depth(ft), s=slope(ft/ft) Tabies From the NC Erosion & Sediment Control Manual (unless otherwise noted) Job Name Camden Oaks -Piney Rd Ext Subiect PERMANENT DITCHES DETERMINE GRASS LINER PROPOSED GRASS LINER: TALL FESCUE Use Retardence Class D Job No. Date 7/7/2017 Sheet By KEH Chk By APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL: AVERAGE SLOPE: MAX VELOCITY allowed MANNING'S (n) used: MAX VR allowed: PD -3 2.00 % 5.50 feet/sec 0.045 2.2 _ _ - - - _ ',` - DISCI-WRCE FLOW���'•1,;':VIIETTEI�r,..�;<<_�CRI'rICAi:�- :;�'�- - _ _"- •`- _ kriRM�ER EPTHeoo= d);ft: - �:ftlfk�` � 1111idtiiV. flsj�`� �Q.'(cfs;,�� (Sgrft?;.�. "':, _ '`(ft}�;_ - :(ftjty:��.�• 0.97 3 1 3.05 11.45 3.75 7.10 0.83 0.73 1.61 FLOW IS SUBCRITICAL VELOCITY CHECK Calculated velocity of VR CHECK Calculated VR 3.05 feet/sec is less than permissible velocity of 1.61 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a grass liner for PD -3 *Permissable Velocity Obtained from Table 8.05a "VR = Velocity * Hydraulic Radius = Velocity * Flow AreaMetted Perimeter Tables From the IVC Erosion & Sediment Control Manual (unless otherwise noted) Fla 5.50 feettsec SUPPORTING DATA D6 i ,�a,-,-- ' 104 —ricy >I I I' 07 RD(1 00% DA= i.9 C ,,3 • 50) I /�<f 7A�0.sac 52 Piney Dr. 45' Public e3(2.00%)_ e //, 2 DA=3.00A g 524 518 01 r 40akc> t -- 5] 9/13/2015 Precipitation Frequency Data Server I1OAA Alas 14, Volume 2, Version 3 Location name: Monroe, North Ctr0lina, US* Latitude: 35.04390, Longitude: 40.4719° Elevation: 506 ft* s source: Google Maps , POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonin, D. Martin, B. lin, T. Parzybok. M.Yektat, and U " HOAA,. National Weather Service, Silver Spring, Matytsad ff-ja�vk i EE -911[1009 1 a PF tabular pDS bast point pr®airipitaucn ftquen cy estimates with 90% confideffln Inbar talc (in Ing d9 Average recurrence Interval (yearn) Durati®n 2 510 L _J 200 20fl 500 10005•rrtln 0.�9_T_ 5.AO6.602 7.68 B.�T 9.A2 i 9.53 9<9T 10.6 - 10.8 (4.68-5.53) (5.528.56) (6.40.7.60) (7.02.8.34) (7.73-9.18) (8.18-9.78) 11 (8.60-10.3) (898108) (9.32-11.4) 10 -min 4.06 4.80 (3.74.4.42) (4.41-5.24) 5.58 6.14 8.75 (5.12.8.08) (5.62-8.67) (6.18.7.32) 7.18 (6.52-7.79) 7.57 (8.63.8.20) 7.90 (7.10-8.57.) 8.29 8.63 (7.38-9.01) (7.54-9.30) 4.02 4.71 5.1Zi; 5.70 6.06 8.38 GAS 893 7.14 15 -min 3.38 (3.12-3.68) (3,70-4.39) (4.32-5.13) (4.74.5.62) (5.20.8.18) (5.50.8.57) (6.78 8.91) (5.97-7.21) (6.19-7.56) (6.31-778) 2.32 2.78 3.34 3.76 4.22 4.57 4.88 5.17 635.78 -5-1 30-sanflu (213-2.52) (2.55-3.03) (3.07-3.64) (3.43.4.07) (3.85-4.68) (4.14-4.96) (4.41-5.29) (4.66-5.61) (4.93-6.02) (5.11-6.30) 1.74 2.14 2.44 2.81 3.09 3.36 3.83 3.E7 4.22 6 60=rvaln 1AS (1.33-1.57) (1.60.1.90) (1.97.2.33) (2.23-2.65) (2.56-3.05) (2.81-3.35) (3.04.3.64) (3.28-3.94) (3.53-4.32) (3.73-4.60) 1.0 6 1.25 1.44 1.88 1.86 2.04 2.29 2A3 2.63 2 -hr 0.836 (0.766-0.914) (0.926-1.11) (1.15-1.37) (1.311.67} (1.52-1.83) (1.68-2.02) (1.83-2.22) (1.98-2.41) (216-2.87) (2.30-2.87) 0.715 0.892 1.03 1.21 1.38 1.30 1.60 1.86 2.02 3 -hr 0.592 (0.541-0.651) (0.654-0.787) (0.815-0.981) (0.938 1.13) (1.10-1.33) (1,22-148) (1.34 1.84) (1.47-1.88) 6°hr 0.356 0.430 (0.394.0.472) 0.637 0.621 0.735 (0.491-0.589) (0.566-0.680) (0.665.0.802) 0.825 (0.742-0.899) 0.918 (0.820-0.999) 1.01 (0.897.1.10) 1.15 125 (1.00-1.26) (1.08-1.36) 12 -hr (0.326.0.392) 0.290 0.253 (0.192-0.230) (0.232.0.279) 0.318 0.369 OA40 (0.291.0.349) (0.337.0.405) (0.399.0.481) 0.'698 (0.447-0.643) 0.297 {0271-0322) 0.557 (0.496-0.807) 0.333 (0.302-0 .361) 0.620 (0.545-0.676' 0.370 (0.335-0402) 0.708 0.779 (0.6120.769) (0.6640.848) 0422 0.484 (0.380.0.459) (0.415-0.505) 0.242 0.265 (0 218 0.283) (0238-0290) 24 -hr 0.125 (0.116 0.136) 0.151 (0.139.0.164) 0.190 0.220 (0.175.0.206) (0-202-0-239) 0.283 (0.241-0285) Q.088 (0.082-0.096) 0.110 0.128 (0.102-0.120) (0.198 0.139) 0.152 (0.140.0.165} 0.171 (0.157-0.186) 0.193 {0.176-0.208) 0.213 (0.193-0231) 2�Ia�t 0.073 (0.068-0.080) 0.052 0.062 0.077 0.069 0.106 0.119 0.133 6.148 0.168 0.184 (0.152-0.182) (0.166 0.200) 3 -day (0.048.0.058) (0.058.0.086) (0.072 0.084) (0.063.0.097) (0.09&0.115 ) (0.109-0.129) (0.122-0.144) 0.104 (0.095-0.112) (0.1340.160) ®.11s (0.105 0.124) 0.131 0.1 (0.119 Q.942) (0.130 0.156) 4�da�1f 0.041 O.D49 0.081 0.070 (0.065 0.078) 0.083 (0.077-0.090) 0.093 (0.086-0.101) (0.038 0.044} 0.027 (0.048-0.053) (0.056.0.068) 0.032 0.039 0.045 0.036) (0.037 0.042) (0.042.0.048) 0.053 (0.049.0.057) 0.059 (0.055-0.084) 0.066 (0.051.0.071) 0.072 ) (0067-0.078 0.083 0.090 (0.075-0.088) (0.082-0.097) T'day (0.026-0.029} (0.030 0.02% 0.028 0.031 0.038 0.041 0.046 0.050 OA55 0.089 0.065 10-d0y (0.021-0.023) (0.024-0.028) (0.029.0.033) (0.03&0.038) (0.038-0.044) (0.042-0.049) (0.047-0.053) (0.051-0.059) (0.056-0.085) (0.081-0071) 0.016 0.017 0.020 0.023 0.026 0.029 0.032 A.A34 0.038 ®=049 (0.022.0.024) (0.025-0.028) (0.027-0.031) (0.030-0.034) (0.032-0.037) (0.035-0.041) (0.03&0.044) 2A��y (0.014-0.016) (0.016.0.018) (0.019-0.022) Q� 0.012 0.014 0.016 0.018 0.021 0.Oa2 O.A24 0.026 0.028 O.A3A 30 -day (0.011-0.013) (0.013-0.016) (0.016-0.017) (0.017-0.019) (0.019-0.022) (0.021-0.024) (0.023.0.028) (0.024-0.028) (0.027-0.030) (0.028.0.032) 0.012 0.014 0.015 0.017 0.018 0.019 0.020 0.022 0.023 0.010 45-doy (0.010-0.011) (0.011-0.012) (0.013-0.014) (0.014-0.016) (0.016.0.017) (0.017-0.019) (0.018 0.020) (0.019-0.021) (0.021-0.023) (0.022-0.025) 0.009 0.011 D.012 0.013 0.014 0.01$ O.A1aa 0.017 0.019 0.A20 aA18) {0.016-0 09r") 0.018-0018) (0.098 0.020) (0.019 Q.021) 60 -day (0.009-0.009) (0.010-0.011) (0.011-0.012) (O.A42 0.014) (0.014-0.015) {O.A16 in this table are based on frequency analysis of parbat duraft series (POS). 1 Precipitation frequencY (PF) estimates a4 the 90°% conwanca interval. The probabMy that precipitation frsaptenay esUrnstaa (%r a to are PF est at fewer and upper bounds the � at upper bounds, are not less reentlyy Numbers parenthesis given duration and average reaurrers*a four 4 w(M P � Wd upper be hWMr then urrat vaW FMP vvahm. against probable maximum PrOdPftd ( ) checked Please refer to NOAH Alias 14 document for more wormatton. Sack #o Too PF grapiaicai http://hdsc.nws.noaagov/hdsc/pfds/pfds_arintMe.himl7lat=35.04.3Mor_-W.4713&ClSta=tnWmif r&mits=er4ish&series=pds 114 Table 3-9 2 Roughness Coefficients (Manning's n1' for Sheet Flow Surface Descrilaft P - Smooth surfaces (concrete, asphalt gravel, or. bare soil) 0.011 Failow (no residue) 0.05 Cultivated soils: Residue cover < 20% 0.06 Residue cover > 20% 0.17 Grass: port grass prairie 0.15 Dense grasses 0.24 Bermuda grass 0.47 Range (natural) . 0.13 Woods' Light underbrush 0.40 Dense underbrush 0.80 'The n values are a composite of information by Engrnan (1986). alncludes species such as weeping lovegmss, bluegrass, buffalo grass, blue gamma grass, and native grass mixture. 'When selecting n, consider cover to a height of about 0.1 ft. This Is the only part of the plant cover that will obstruct sheet flow. Source: SCS, TR -55, Second Edition, June 1386. .5 .4 .3 .2 ra CD A6 .06 .04 02 .I Sip 10. For grass -lined channels once that appropriate channel dimensians have been selected for low retardaum conditions, repeat steps 6 through 8 using a higher retardance class, corresponding to tall grass. Adjust capacity of the channel by varytmg depth where site conditions permit. NOTE 1: If design velocity is greater than 2.0 fdsec., a temporary liidng may be required to stabilize the channel untni vegetation is established. The temporary liner may be designed forpeakilow from the 2 -year stw n. If a channel requires a temporary Iiailag, the designer should analyze shear stresses in the channel to select the liner that provides prof on and promotes establishment of vcgetatk& For the design of tempoz!`any liners, use tractive force procedure. NOTE 2: Design Tables—Negetated ChamwIs and Diversfions at the end of this section may be used to design grass lined channels with parabolic cross-sections. Step 11. Check outlet for carrying capacity and stability. If discharge velocities exceed allowable velocities for the receiving stream, an outlet protection structure will be required (Table 8.05d, page 8.05.9). Sample Problem 8.05a illustrates the design of a grass -lined channel. .2 .4 .6 .8 IA 2 4 ss iu VR, Product of Velocity and Hydraulic Radius Ftgum "5c MmWng s nreiated to vebdV, tt ftWt® rafts. and vegaW retardance. Nola: From Sample pMblem 8.05a rr urdpV Vp x l ydraprAc Radhra (4.50.54=2A4 then ardor the productof VR and exp a straight One up to Retardance des °17. next project a stratgtu Ano to the 19tt to determine atrial manning s n. 8.05.9 Rev. 12193 ' Sd'� ��yy ppa�yy �• K�l�� A .t' Hydrologic Sod Group—Union County, North Carolina (Oaks at Camden North Phase (Piney Dr. Ext.)) Area of Interest (AOI) Area of Interest (AOI) Solis Soil Rating Polygons 0 A Q AID Q B BID Q C Q CID 0 D Q Not rated or not available Soil Rating Lines ,*t# A ,r AID �* B ,mea BID s.d C •,r CID 0%p D # d Not rated or not available Soil Rating Points ® A ® AID ® B ® BID ® C ® CID ® D ® Not rated or not available Water Features Streams and Canals Transportation Rads e Interstate Highways US Routes Major Roads Local Roads Background [,-]E, Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Sod Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale Please rely on the bar scale on each map sheet for map measurements. Source of Map. Natural Resources Conservation Service Web Soil Survey URL Coordinate System* Web Mercator (EPSG:3857) Maps from the Web Sod Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Sod Survey Area- Union County, North Carolina Survey Area Data Version 16, Sep 20, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed' Feb 11, 2011—Feb 13, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. USDA Natural Resources Web Soil Survey 7/8/2017 Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group—Union County, North Carolina Hydrologic Soil Group Oaks at Camden North Phase (Piney Dr. Ext.) Hydrologic Soil Group— Summary by Map Unit ® Union County, North Carolina (NC179) Map unit symbol Map unit name Rating Acres in AOI Percent of A01 1 RaR R—lin rhannonr df i f w n n 1. loam, 2 to 8 percent + slopes f ; BaC Badm channery silt C 4.8; 24.2% i loam, 8 to 15 percent slopes BdB2 1 Badin channery silty j C ; 2.4 i 12.4% clay loam, 2 to 8 1 percent slopes, moderately eroded j ScA Secrest-Cid complex, 0 C 1.21 .5.9% to 3 percent slopes I i TbB2 Tarrus gravelly silty clay ; B 0.4; 2.0%' loam, 2 to 8 percent slopes, moderately jeroded Totals for Area of Interest 19.7— 100.0% usDA Natural Resources Web Soil Survey 7/812017 MM Conservation Service National Cooperative Soil Survey Page 3 of 4 i OAKS AT CAMDEN (NORTH PHASE) Unionville NC REVISED STORM DRINAOE & EROSION CONTROL FOR ADDITION OF PINEY DRIVE Ron Rushing Camden Oaks LLC Kevin E. Herring PE 16101 Silver Road Oakboro NC 28129 (980) 621-0935 RECEIVED JUL 312011 DENR-LAND QUALITY STORMWATER PERI IT 11,1., 0 z .o 0 YI' N O c a� E co U .a O 3 U) CL LL z w p w O d 2 W H p w UJ U () .fl U) b c M 2 0 9 c O U c E N W ca .o O O O 00 L W L tM Z li L LU w MM 000N O N MNI�rs� CA M d' C� ONMM M M 00 O qu I1) O0 I-� N u� C C 0 O r r r O � T O N T T T O (V M 0 0 0 Ci O^ cT� 00 cocflco co 00 0o mcomcommcocfl(flcocflmco co 00 00 co 0o 00 co co co W 0o w c c Ln ►o an �n Ln n � In in Ln U') LO Ln 0 O Il Cl CO O (O O (0 O CO O co O co O O O co O Lo O w O (D O CO N LO M to O (O O (O 4Y9 O O O 0 0 0 06 0 06 0 0 0 0 0 U w r CC) r- C, coNCOOCDco�c.'00M a.� V =�Q NNN O O6 CgM000MNNr C O O O O6 C O CO O rTT'M O O C H Q O CO p 1 � W �O �Q r(O1� Or00N(OCA00�'Or(000 NMOLOM Nrd'OpNTT- iz�Q NNN 6 6 0 0 0 0 0 0 0 0 0 0 o 0 o 0 5p 7 n- rNM M 0U.)Qm00 000)Cl 9 14' ' (9 CC) (0 (4 C b c M 2 0 9 c O U c E N W ca .o O O O 00 L W L tM Z li L LU w O Z O Y (a 0 (D E w U .Q O 3 LY E W m VVV VVvVvvVvV'aVVV J M) LA Ln In 0 LL) LLQ W Lf) In O Ln Ln In Lf) Ln N N I N N N N N N N C'41 04104 N I N N N xxx xxxxxxxxxxxxx �_ CO WOM Lf) = OMOOON Nto 0 a M Loo p ce)ce) MMNU')!Vice) MNd LnNNN LL Z O g p x x x x x x x x x x x x x x x x ULAN et000N000O001nOLnLL)MM r r r r r r N r r r r N N r r r 0 O Lq In Ln 0q O 10 LO LO LO In LO Ln LL) LL) In fn k rrr OOOrrr a [1S1 O LO LO LO LO LO LO LO LC) LO LLi LLI o)00 It V' 00000 V V d' J m W 0 ou>Ln000O000000 �} eh (V e4 t 0 00 r Ln r LO r y N Li) LO N LL) N C44 LO T- r 0 r w T- r LO T- r w T.- r 0 O w tp 00 00 It Do M V 00 00 V in S O O 0000 O O O N N O O O � p U IT �Y corr LO O O A OrVNrrr�v-CNI N O N LL)Ig000000 r r r 00 L() Ln 1- In 10110 In d ` W 0 O CO CO N CO V7 CO It O W ��� ti�N�rti���N�L~nLtin O 5 oLno 00000cocOLno�LnLnLn O a NNS etLnO NMOrN1�t�f-ONI-NN d CONrI�LnInMtArMMM � Z O O Q� O O O O O O O O O O O O O O O W r Cia r r r r Cl v Ci r U' r dC1CiC�C'JC1C3C1C1C1 r r r r e- r r r r r ' i LL U Lfl r M r N CO M O L� r r (O O r C CO LO r O co Ln 00 r O L- 00 r 00 r W w I I I Ln to It(OrC)Ll.LO Ln0700�MLMM i s W ll NM 0o U 0 Q oo U aornrr O r o r "r 0(O FL LO FL I -LW a c~i) t~n v~iFL v~)i) (1) U) (00 U)i Cl) ) CO c~/� CO U)! a e 1 F- W O 07 W d u) W 0 N Z O 0 W U) m 0 W D O w CL 0 W J Job Name CAMDEN OAKS -Piney Job No. Subject STORM DRAIN (RATIONAL METHOD) STORM DESIGN YEAR, Varies DETERMINE DRAINAGE AREA ENTERING CULVERT Date 6/2312017 Sheet By KEH Chk By Drain PIPE Area (Ac) P-6 030 0.30 Runoff Coeff "C" 050 050 Calculated Tc(min) 5 5 Used Tc min 5 5 Storm Design YR 10 25 NOAA I in/hr 768 8.47 Frequency Factor 1.00 1.10 Discharge Q (cfs) 12 1.4 Plastic Pipe 0 010 Smooth Steel Pipe 1 0 010 18 0 50 594 MATERIAL Manning n Concrete Box Culvert 0 015 Concrete Pipe 0.013 Corrugated Metal Pipe 0.024 Plastic Pipe 0 010 Smooth Steel Pipe 1 0 010 DETERMINE MINIMUM PIPE SIZE USING MANNING EQUATION Drain PIPE Area Discharge Q(25) Manning's n # of Lines Slope S ft/ft) Proposed Size (in) HW/D Velocity (fps) P-6 0.30 2 0.013 1 00100 18 0 50 594 0 MANNING'S EQUATION FOR PIPE FLOW Project: Camden Oaks Location: P6 (Piney) By. Date: 6/23/2017 Chk. By: Date: mdo version 12.8 00 Clear Data A Entry Cells � INPUT (Mannings Formula d Q=(1.486/n )AR'13S' 11 R=A/P A=cross sectional area P --wetted perimeter S=slope of channel n=Manning's roughness coefficient Wetted Hydraulic Area,e Perimeter, ft Radius, ft 1.77 4.71 0.38 Created by. Mike O'Shea V=(1.49/n)R^1' Q=V x A to city ft/s flow, cfs 5.94 10.50 D= 18 inches d= 18 inches n= 0.013 mannings coeff 8= 0.0 degrees S= 0.01 slope in/in n -values PVC 0.01 PE (<9"dia) 0.015 PE (>12"dia) 0.02 PE(9-12"dia) 0.017 CMP0.025 ADS N12 0.012 HCMP 0.023 Conc 0.013 1.0 i2 HEADWATER DEPTH FOR CiRcu LA:ft, HEADWATER SCALES 2813 CONCRETE PIPE CULVERTS REVISED MAY 864 WITH INLET CONTROL BUREAU OF PUBLIC ROAD$ JAIL 1943 WR -2.4 C HART 2 160 10,000 (3) 166 8,000 EXAMPLE 6. 0.42 inches (3.5 feet) 6. 156 6 AOA 0.120 efs 5, 144 5 000 6. 5. 4,000 he mw 132 3 000 D fast ` (I) 2.5 8.8 5. 4. 4. 120 (2) 2.1 7.4 2,000 (3) 2.2 7.7 4. 3. 106 NO in feet 3• 3. 96 1,000 600 2- 64 600 / 500 0 2. 400 3 W 72 300��j/ r, 1.5 1.5 / Z 60 v 200 FW- 1.5 z a 0 54 ® c W 100 Z W -46 / w 6o / = 60 1Z 1.0 1.0 U. 442c 50 HW ENTRANCE W 1.0 40 SCALE D TYPE Cr w H 36 30 (I) S®••r• edge with � .9 .9 .9 W headwall Q 33(2) ZO Groove end With Q W _ headsall = •6 .8 30•9 (3) Groove and projecting 27 10 •T .T ® .7 24 6 To use scale (2) or 131 project s horizontally to scale (1), than 21 use straight inclined line through 4 D and 0 scales, Or rerars• a• .6 .6 3 illustrated. 6 1.0 i2 HEADWATER DEPTH FOR CiRcu LA:ft, HEADWATER SCALES 2813 CONCRETE PIPE CULVERTS REVISED MAY 864 WITH INLET CONTROL BUREAU OF PUBLIC ROAD$ JAIL 1943 WR -2.4 Job: Oaks at Camden -Piney Addition Job No. Date 6/23/2017 Sheet Subject: Apron By KEH Chk By 4PR®F!:(18"RCP) ��------- -�------�-- _ .._-------- _•___._.__�._�___ Pipe Diameter, Do 18 Inches or 1.5 Feet RECEIVING'OUTLET (CHANNEL ! SHEET FLOW): CHANNEL i Apron Length, - L= 10 Feet (from Fig 8.06a) Channel Width, b= 0.5 Feet Side Slope, M:1 = 3 :1 H (213 Pipe'Dia): = 1.0 Feet Apron Width, W1 = 4.5 Feet (3 * Pipe Dia.) Apron "Width, W2 = 6.5 Feet d5o Stone Size = 0.5 Feet (from Fig 8.06a) = 6 inches Apron Thickness, t=- 13.5 inches M DO L DUO— da tib._„ 4 , `Ji y �t ;�•ar � `' � - • ' � ' � ` ! � ',''� °`'fir f 71 i- 'tie. `ti. :Sy �. : I.} ? ,_- li-d - '�+ _ rt- • a}-•. � .�� �* t• -�j3 �,,F•''��,�'• I r d 77 T— It : 2 CSC 4 rt 1i= �,1J•'a,: � err_.' rr_+t,rla {iiC11dF±1.dtw�' Itau+fit7lia:,e3�;f,.}'-.s;t;,-,-r'_x•:.:nlr:l-ci.t-:-:. ra61.C.:.- t:A..-,t'A,1"•D11-:1C,7a5xrm,-11S�-.1�T•r1=•�-9�4'•�Jtl Job Name Camden Oaks -Piney Rd Addition Job No. Date 6/23/2017 Sheet Subject ROADSIDE DITCHES By KEH Chk By DETERMINE TEMPORARY LINER APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Velocity is checked to see if Temporary Liner is required. If required, 2 year storm is used for design. Shear Stress is then compared to Permissable Shear Stress allowed. PROPOSED CHANNEL: RD -1.5% DRAINAGE AREA: 0.30 Acres MAX SHEAR Td allowed: 1.45 AVERAGE SLOPE: 1.50 % VELOCITY CHECK of Channel Design using Manning of 0.02 (Bare Earth) Calculated VELOCITY of 2.81 is GREATER THAN 2 Feet per second TEMPORARY LINER REQUIRED (USING 2 YEAR STORM FOR DESIGN) PROPOSED LINER: STRAW WITH NET *MANNINGS (n) of 0.065 used for design DISCHARGE** DEPTH VELOCITY Calculated Shear Q cfs d ft v (f/s) (Td **** 0.89 0.44 1.10 0.42 Calculated shear of 0.42 is less than the Permissable Shear*** of 1.45 Therefore STRAIN WITH NET can be used as a temporary liner for RD -1.5% `Mannings Coefficient obtained from Table 8.05e **RATIONAL METHOD USED TO DETERMINE DISCHARGE Q=CIA Where C= 0.5 1= 7.63 in/hr for channel design,Tc= 5 min 1= 5.96 in/hr for 2 year storm REF: NOAA Atlas 14 Data —Permissable Shear Stress Td obtained from Table 8.05g *'*'Td=yds Where T --Shear Stress(lb/sq ft), y=unit wt of water, (62.4lb/cubic ft), d ---flow depth(ft), s=slope(ft/ft) Tables From the NC Erosion & Sediment Control Manual (unless otherwise noted) Job Name Camden Oaks -Piney Rd Addition Job No. Subiect ROADSIDE DITCHES DETERMINE GRASS LINER PROPOSED GRASS LINER: TALL FESCUE Use Retardence Class D Date 6/23/2017 Sheet By KEH Chk By APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL. RD -1.5% AVERAGE SLOPE: 1.50 % MAX VELOCITY allowed: 5.50 feet/sec MANNING'S (n) used: 0.045 MAX VR allowed: 2.2 1 � d M b DISCHARGE FLOW WETTED CRITICAL DEPTH Side Slope Bottom VELOCITY Q=CIA AREA PERIMETER DEPTH FROUDE (d) ft ft/ft Width (ft) V (f/s) Q (cfs) (sq ft) (ft) (ft) No Fr VR 0.43 3 0.5 1.54 1.14 0.74 3.17 0.31 0.55 0.36 FLOW IS SUIBCRITICAL VELOCITY CHECK Calculated velocity of VR CHECK Calculated VR 1.54 feet/sec is less than permissable velocity of 0.36 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a grass liner for RD -1.5% *Permissable Velocity Obtained from Table 8.05a **VR = Velocity * Hydraulic Radius = Velocity * Flow Area/Wetted Perimeter Tables From the IVC Erosion & Sediment Control !Manual (unless otherwise noted) 2.2 5.50 feet/sec Job Name Camden Oaks -Piney Rd Addition Job No. Date 6/23/2017 Sheet Subject ROADSIDE DITCHES By KEH Chk By DETERMINE TEMPORARY LINER APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Velocity is checked to see if Temporary Liner is required. If required, 2 year storm is used for design. Shear Stress is then compared to Permissable Shear Stress allowed. PROPOSED CHANNEL: RD -4% DRAINAGE AREA: 0.41 Acres MAX SHEAR Td allowed: 1.45 AVERAGE SLOPE: 4.00 % VELOCITY CHECK of Channel Design using Manning of 0.02 (Bare Earth) Calculated VELOCITY of 4.38 is GREATER THAN 2 Feet per second TEMPORARY LINER REQUIRED (USING 2 YEAR STORM FOR DESIGN) PROPOSED LINER: STRAW WITH NET *MANNINGS (n) of 0.065 used for design DISCHARGE** DEPTH VELOCITY Calculated Shear Q (cfs) d ft v (f1s) (Td **** 1,22 0.41 1.71 1.03 Calculated shear of 1.03 is less than the Permissable Shear*** of 1.45 Therefore STRAW WITH NET can be used as a temporary liner for RD -4% *Mannings Coefficient obtained from Table 8.05e **RATIONAL METHOD USED TO DETERMINE DISCHARGE Q=CIA Where C= 0.5 1= 7.63 in/hr for channel design,Tc= 5 min 1= 5.96 in/hr for 2 year storm REF: NOAA Atlas 14 Data ***Permissable Shear Stress Td obtained from Table 8.05g ****Td=yds Where T --Shear Stress(lb/sq ft), y=unit wt of water, (62.4lb/cubic ft), d --flow depth(ft), s=slope(ft/ft) Tables From the NC Erosion & Sediment Control Manual (unless otherwise noted) Job Name Camden Oaks -Piney Rd Addition Job No. Subject ROADSIDE DITCHES DETERMINE GRASS LINER PROPOSED GRASS LINER: TALL FESCUE Use Retardence Class D Date 6/23/2017 Sheet By KEH Chk By APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL: RD -4% AVERAGE SLOPE: 4.00 % MAX VELOCITY allowed: 5.50 feet/sec MANNING'S (n) used: 0.045 MAX VR allowed: 2.2 1 d M b RGE,DISCHAWTED.: f, = - I' 1FR�UDE"s -DEPTH;- ,Side'SSIo`"i;� LO,CTY�` _ �f - Alo ^Fr `{d};,ft�" ,�'ft/ffr.E,' .,�Ulftitti (ft�:A��;� _ (f )`., �Q�( )'r�'`�� s(Q )•_.. ..�'s,a= (). �.;`�_�:,���S,Y.. ,( )^`�� _ ��v'r�, 0.39 3 0.5 2.40 1.56 0.65 2.97 0.36 r 0.88 0.53 FLOW IS SUBCRITICAL VELOCITY CHECK Calculated velocity of 2.40 feet/sec is less than permissable velocity of VR CHECK Calculated VR 0.53 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a grass liner for RD -4% *Permissable Velocity Obtained from Table 8.05a *'VR = Velocity * Hydraulic Radius = Velocity' Flow Area/Wetted Perimeter 2.2 5.50 feet/sec ST13 'TI 3 2 N ®A (; s°E ST As DA \°`L ®• 9 .A 0 gin IN EWA__ 1 it • Job Name Camden Oaks -Piney Rd Addition Job No. Subject ROADSIDE DITCHES DETERMINE GRASS LINER PROPOSED GRASS LINER: TALL FESCUE Use Retardence Class D Date 6/23/2017 Sheet By KEH Chk By APPROACH: Channel Design calculated using NORMAL DEPTH procedure. Calculated VELOCITY is compared to MAXIMUM VELOCITY allowed for liner. Calculated VR is then compared to Fig. 8.05c to determine if design is within range for prop.RETARDENCE CLASS PROPOSED CHANNEL- RD -4% AVERAGE SLOPE: 4.00 % MAX VELOCITY allowed: 5.50 feet/sec MANNING'S (n) used: 0.045 MAX VR allowed: 2.2 1 d M b DISCHARGE FLOW WETTED CRITICAL DEPTH Side Slope Bottom VELOCITY Q=CIA AREA PERIMETER DEPTH FROUDE (d) ft ft/ft Width (ft) V (f/s) Q (ds) (sq ft) (ft) (ft) No Fr VR 0.39 3 0.5 2.40 1.56 0.65 2.97 0.36 0.88 0.53 FLOW IS SUECRITICAL VELOCITY CHECK Calculated velocity of VR CHECK Calculated VR 2.40 feet/sec is less than permissable velocity of 053 is less than the maximum allowable VR of Therefore TALL FESCUE can be used as a grass liner for 'Permissable Velocity Obtained from Table 8.05a "VR = Velocity' Hydraulic Radius = Velocity' Flow Area/Wetted Perimeter RD -4% 2.2 5.50 feet/sec T 6 DA=0.30a SDE 20� r•1 0 I Flr:_IM'EWJC,-'iJGrr'.JG•:•'•' �;�-,•.� NCAA Mies U, Volume 2, Varst9�13 Loeartion nasties: MonraD, %,orih Carolina. US* t Latitude' 35.c=4391Longitude: -50.4719' f Elevatlan: 503 ft` },a >J ' SaUCG`_' �M�i9 A{303 • ^' FOIh)T pREWIT TION FREQUENCY ESTIMATES G. J.'3:t.-t. S. Lr. T, and G. "!BY FiDA.1. h iGc.s! Yde4tner Sar%ic^., S3•, Sa�a�, i.try'= td aL92I C.h� ( L1aS r �r �• PF tabular _ s�� int pr�ctpitation frequency esthtimates with 9to confidence intervals (in Inche:,�i�ur} � I) �I Average recurrence role vti� ; 50 ! 104 Ij ifJD ! o 11 Ot}0 � Duration'�g ] 2 �� ;[ iu I� j^� 5 initt .I {G-059 ` 3} �{5.�6�.0g1.-a} II !3 tft . 7.cr�•� 717.4i.00E. 'i� ,I.f°.53 L(.9;6.97174� G.Bj I1 (5:$124• .i5 i •'-1 ( , 4�•SO4' •$ •`°': iI - e.14 6.75 ?. i S 7 �Jd �4-80 5^58 1 o a?-%=r�,) {£.Ea b.�]) ! (7.?G•B.� } ' �'7a 14 ruin ',` ?4-4.Q) (5 •� S.CLS; (5.a2 G.E } !l (6 ;8 7.`x2) i ( 0 1 5.43 S.r 0 8.08 6-38 pp (�f� 3.71 r] 1 i� L C�C•�� i _ r } y � ?.s^t) ` !r=.1?7.53t-7 1I 11 J.•/V I� �02 �) i (y .^. •5.43} I� ( •r -O. I(Sr I J.4J.i3-r'.Ji (J.rt• _ «l -F-----����L--}---- 111 -rr---4 22�-i^! 4.57 +a.93 5.17 I 5 5s 15.78 I--' 2 2.78 3 4 ; 3.75 ��-II -, �i 32 1I s.0" (3 ES 4.FE) I {S.id•s. p;:.T37 ,i L sQ-min i (�13 ? (2..�=.031 130, '•3.G:) :I {r 3,-�' } I 3.07 i 9ti2 - -- _---�-2:14, 2 4�r 2.81 3.08 3.341 3.03 I� 1.7�i I (1 8t 7.2 331 (2 23.2 G5j I �i�•3 tJ5 I� L.B;•3sysl (3.24 _94) (�=•3i) (3?3 A.G f) 6Q-nilnt,ga) �tom._ ) { 2.s3 t.---� -- --L - �1.6 1.69 2.21 i' 2A5 0 !' 1 01 a 1.25 J •i• -r I ( } I ( 1�$f J ' ( �} I f S 3&2H1} (27Fr2.67) !? ?.J 2.8T1 I 2-11T ; (0 ; 6C G.3 f ;)�[ (O E' °2c t•' 11 ���i 39) ( =.192 (0•�3�0�.O.ti3i0) ) lIIU.Cn 2a!1 ff1}2_}' .(C('i.7i.722 4.4z?8}9) 1I�!(C(iBc� i.o.}1 �?464: 2.D2 Da22 1.36 I l7-t.f}5O.r1E0 :3 -hr 03250.73.Mia 0.537 O- � ? le3X.a o6'ar�3 5 , 7 } ,i �0G2.G0d44.ia.A11J50a2.6i15_)I(L-(D_t_Oa�itv_a ((( aO.O,iQr?5^.21-5•G'33C7...2y 0JiL1i ' (��!0(O0._=..iO4104r.j5xt.'o.•7115 2CA4o1(1=9.70fi2D1);]i(�(; � 'ji � ,Di0G-.t�.3.2DG2E.•17nGE-2.7.SC`0?r93)1}1 I(".ca- IIIff� {i c.Dt;0 .a57B.-1 7.iDOE-9.x'5d_ 6 0 1 0 ){(5Dg1 9 0:30 (0.� a;2)90.783L G =-h 0�4xOr96 do 65--0.435?1)}; 0-25-3 0.3 _G2.0..9•..0 0422 0.404 C0�7 0 hif2 0 7 0 2�6 612 3 5110.•0S(U s71 3-J�{U.30C2 9-C.t?4)(07920S)1 0.205D.242 5Oi 7i -3?12-0.1120),G0.128 {O.iO4. (( 52 G.1 ,) (0155-0.2=1 ' ��1 2io0_d--ctalyt1a-r=Y r� .�`'` i,1Gl`1� [-o(i`` 0(C.o.-.nOO.T0fl<ax'i0-.t.�0".- �-i'viO2rJ2..UaG�- i�3o}i-))��i4}j I(�!�(o(✓(D0c.c.n`0o0O2-4�l»0 .i•o00.1v�.z-10a-(.1ii:.1g))4)•((;-�1 tr zt(xDU0.^000s0::.9 •0. 60t 12C_.O'.a404AAt.:G8'�-i2> )i,,Y I)e1�0(tIUtf� .G.?OD.yGS.0.r n73_9qmv5 5� .fsry}I; j I j r 7c.7y.0052tx 6 s.0}II'� (i i OG(60.0.x44.505$1O2 3O i 0 �xUt-.an 0.131 .3501U 2 i1 wI!'DtGG. iD.0 QD0D.a..a94a-rx4rs6OZ1.^rOREo21O3Z31}!J.G1 O-Eb2 7414, �a F Q.10 3-day0083 0.oq 0.0 -1 OSrrAQ1 (0.( .072 pA3_O6D7t0.93:GrS U UU-.027 G42},E10142-0-04 O.O(o tf-, 0.04GT 0ro)1G0.0 1 ( y ± 4.55-Dc5t (0.06-1-0.0 0. 0i00D °)_000�0.081.02a 0.02 4,140 .o1D{0 �2 e.43tFT2" rOC_?GD3;)(0O.G332 O 0.030 02003OGo.oa0`24) (0.. ) n ^ �U?iI{G 02 _0.012 0.o15)1O-' --!,r- 008sI��Q0.0_2 O.a23(.1), S01 s 0) G_1t3}Iay I 002030�-d`3 QA100. O0.079 G2 1) 621-�3i8)�(0.022-0.0- 0.012 0.022 O.�DG 0 J 0.�012 c;a} ( o 016.10 G:7 t�)D 010 0.020o01Di3 O.QiG 7 Qtg d5-cay (Ln,C G G R -b •2 0.-0121I 203 tD.COi iJd01� F.,,tiay (OF G.{aat7 sib(=ae t4 ti1 a,2fJ- 2]4 ]i] )l s ECU:t"GY (Tye i �''• ' tou�6s or tt i ^-recai.att; ' .,: vS•Ha«:� entad+ ;e,r�:,7.�+v1P• titan the uFF�r L:elraD (c� 1&�5 ttxi°a theT63rtt`CFtr 30% nG`o+Ecstax�Y I br w^5 � j ';tL:mbars L^^, pa: GnUlssle era Pr sats�.�£ ' v9i•1 �;tSP t•sdta�. - F,,, �_ .v,rt:':^.^ ansa nr er. u^ r�'�=ror�o'v:la.^. ai) wt'rru.'rtc crwi na. tus nCyf,oar ti ciC?Sf:¢C!'( t �•yCv, lr•h7r') ty i�CI�CC:t b�3 w'_dLT:St F-*Caatrie• rr.��crru+n 4''�%t--. c,.,�st r�d3r tc � tOA� ptl,�s i4 dxurr,¢�t for mcg 1ntc.;ntaticYl. ___-.------- PP graphical -FsJ.-17inxcid.�=1rJ��Ih;3:,Yd'u=�-�!sr,Ps� Ies=lam rnvs r•� co•:h:�^c11;:�s'p(,.��intp.�-�. tr,:S= tri r�=•c.• Permit No. (to be provided by DEMLR) State of North Carolina Department of Environment and Natural. Resources Division of Energy, Mineral and band Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM LOW DENSITY SUPPLEMENT This forni may be photocopied for use as an original A low density project is one that meets the appropriate criteria for built upon area and transports stormwater runoff primarily through vegetated conveyances. Low density projects should not have a discrete stormwater collection system as defined by 15A NCAC 2H .1002(18). Low density requirements and density factors can be found in Session Law 2008-211, 15A NCAC 2H .1000, Session Law 2006-246 and the State of North Carolina Stormwater Best Management Practice Manual. Curb and gutter systems are allowed provided they meet the requirements in 15A NCAC 21-1.1008(g). I. PROJECT INFORMATION RECEIVED JUL. 31 2017 Project Name : Oaks at Camden North Phase Contact Person: Ron Rushing Phone Number: 704 )5§IQ0A�1 ilt?l; Number of Lots: 58 Allowable Built Upon Area (BUA) Per Lot*:13.712 Number of Dwelling Units Per Acre**: Low Density Development (check one): ® without curb & gutter ❑ with curb & gutter, outlets to (check one): ® Swales ❑ Vegetated Area *If lot sizes are not uniform, attach a table indicating the number of lots, lot sizes and allowable built upon area for each lot. The attachment must include the project name, phase, page numbers and provide area subtotals and totals. BETA shall be shown in units of square feet. "(Phase II Post -Construction [non -SAI only) II. BUILT UPON AREA Refer to DEMLR's forms and applications website for specific language that must be recorded in the deed restrictions for all subdivided projects. (http //ortaLncdenr.ora/.a%eb/lr/state-storinwater-forms docs) Complete the following calculation in the space provided below where: • SA Site Area - the total project area above Mean High Water. • DF Density Factor - the appropriate percent built upon area divided by 100. • RA Road Area -the total impervious surface occupied by roadways. • OA Other Area -the total area of impervious surfaces such as clubhouses, tennis courts, sidewalks, etc. • No. of Lots - the total number of lots in the subdivision. • BUA per Lot - the computed allowable built upon area for each lot including driveways and impervious surfaces located between the front lot line and the edge of pavement. • Total allowable lot BUA - the computed allowable built upon area for all lots combined. • Total BUA from lot listing - the sum of built upon area allocated for each lot on the list of non-uniform lots. Form SW401-Low Density-Rev.3-2/10/09 Page 1 of 4 r C.nicn intron For uniform lot sizes: (SA: 3797940 ft2 x DF: 0.2399) — (RA: 115737 ft2) — (OA: 90 ftz) = BUA per Lot = 13,712 ft2 (No of Lots: For non-uniform lot sizes: a. (SA: ftz x DF: ) — (RA: ft2) — (OA: ft2) = Total allowable lot BUA = ft2 b. Total BUA from lot listing: sf. b must be < a III. DESIGN INFORMATION Complete the following table. If additional space is needed the information should be provided in the same format as Table 1 and attached to this form. Rainfall intensity data can be found in Appendix 8.03 of the State of North Carolina Erosion and Sediment Control Planning and Design Manual or at littp:Hhdsc.nws.noaa.gov/hdsc/pfds/ This shall serve as supplemental swales to previously submitted data. 'r„ 1,10 1 QX%7nla rlacian infnrmntinn hn avi nn the 10-yPmr ctnrm_ Swale No. Drainage Area (ac) Impervious Area (ac) Grassed Area (ac) C Q (cfs) Slope (%) Vallow (fps) Vactual (fps) Flow Depth (ft) RD1 1 1.90 0.5 7.25 1.0 5.5 2.10 1.00 RD1.52 0.30 0.5 1.14 1.5 5.5 1.54 0.43 PD3 3 3.00 0.5 11.45 2.0 5.5 3.05 0.97 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Form SW401-Low Density-Rev.3-2/10/09 Page 2 of 4 IV. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the North Carolina Administrative Code Section 15A NCAC 2H. 1000, NCDENR BMP Manual (2007), Session Law 2006-246, and Session Law 2008-211. Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate that the following requirements have been met and supporting documentation is provided as necessary. If the applicant has designated an agent on the Stormwater Management Permit Application Form, the agent may initial below. If any item is not met, then justification must be attached. Only complete items n through p for projects with curb outlets. Page/Plan Initials Sheet No. N/A a. f For projects in the 20 coastal counties: Per NCAC 2H.1005, a 50 foot wide vegetative buffer is provided adjacent to surface waters. For Redevelopment projects, a 30' wide vegetative buffer adjacent surface waters is provided. YN/A b. f For HQW or ORW projects outside the 20 coastal counties: A 30 foot wide vegetative buffer is provided adjacent to surface waters. _ Plans c. ' For Phase II Post -Construction projects: All built upon area is located at least 30 feet landward of all perennial and intermittent surface waters. Attach d. Deed restriction language as required on form SWU-101 shall be recorded as a restrictive covenant. A copy of the recorded document shall be provided to DWQ within 30 days of platting and prior to the sale of any lots. Attach e. Built upon area calculations are provided for the overall project and all lots. -— N/A f. Project conforms to low density requirements within the ORW AEC. (if applicable per 15A NCAC 2H.1007) i�. Plans g. Side slopes of swales are no steeper than 3:1; or no steeper than 5:1 for curb outlet swales. Calcs h. Longitudinal slope of swales is no greater than 5%; for non -curb outlet projects, calculations for shear stress and velocity are provided if slope is greater than 5%. Calcs i. At a minimum, swales are designed to carry the 10 year storm velocity at a non-erosive rate. N/A j. Swales discharging to wetlands are designed to flow into and through the wetlands at a non- erosive velocity (for this flow requirement into wetlands, non-erosive is velocity:5 2 ft/s). Plans k. Swale detail and permanent vegetation is specified on the plans. _ Plans 1. Swale detail provided on plans; includes grass type(s) for permanent vegetative cover. Plans m. Swales are located in recorded drainage easements. Plans n.tt Length of swale or vegetated area is at least 100 feet for each curb outlet. Clacs o.t' The system takes into account the run-off at ultimate built -out potential from all surfaces draining to the system (delineate drainage area for each swale). Plans p.TT Curb outlets direct flow to a swale or vegetated area. f Projects in the Neuse, Tar -Pamlico, Catawba River basins, and Randleman Lake may require additional buffers. tt Only complete these items for projects with curb outlets. Form SW401-Low Density-Rev.3-2/10/09 Page 3 of 4 V. SWALE SYSTEM MAINTENANCE REQUIREMENTS 1. Mowing will be accomplished as needed according to the season. Grass height will not exceed six inches at any time; and grass will not be mowed too close to the ground or "scalped". 2. Swales will be inspected monthly or after every runoff producing rainfall event for sediment build-up, erosion, and trash accumulation. 3. Accumulated sediment and trash will be removed as necessary. Swales will be reseeded or sodded following sediment removal. 4. Eroded areas of the swales will be repaired and reseeded. Swales will be revegetated as needed and in a timely manner based on the monthly inspections. Side slopes must be maintained at the permitted slope. 5. Catch basins, curb cuts, velocity reduction devices, and piping will be inspected monthly or after every significant runoff producing rainfall event. Trash and debris will be cleared away from grates, curb cuts, velocity reduction devices and piping. 6. Swales will not be altered, piped, or filled in without approval from NCDENR Division of Energy, Mineral and Land Resources. I acknowledge and agree by my signature below that I am responsible for the performance of the six maintenance procedures listed above. I agree to notify DEMLR of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title:Ron Rushing Address:3615 Lake Twitty Drive Date: 17 -( 3 2- o 17 Si Note: The legal respond arty should not be a homeowners association unless more than 50% of the lots have been sold and a resident o t -7e subdivision has been named the president. A191,11 tary Pu 'c forState of /V& -Mk O el 114- —, County of do hereby certify that T Ott Pu �l ( personally appeared before me this day of 1 1 and acknowledge the due execution of the forgoing swale maintenance requirements. Witness my h d and official seal, ""-) o, n, - Notary signature NOT-RY SEALP JJ13LIC �G %z �G "Untill 1111%1\\ Form SW401 -Low Density-Rev.3-2/10/09 My commission expires Page 4 of 4 My Commission Expires March 3, 2021