Loading...
HomeMy WebLinkAboutSW3231004_Supplement-EZ Form_20240405 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Banoak Elementary School 2 Project Area(ac) 8.69 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No OOMPLlANGI WItR t(2H MOO" 7 Width of vegetated setbacks provided(feet) 30 8 •Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond _ 23 StormFilter 24 Silva Cell 25 Bayfilter 1 26 Filterra FORMS LOADED DESIGNER CERTIFICATION _ 27 Name and Title: Miles A.Wright, PE,PLS 28 Organization: Wright&Associates 29 Street address: 209 1st Ave South 30 City,State,Zip: Conover,NC 28613 31 Phone number(s): 828-465-2205 32 Email: miles@wrightandassociates.us Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer \\\�� CIA RQc /% •O �F S,g •G,� %_ W., .Q SEAL r : — — : 24934 Signature of Designer "if' SI�1 111N�G\\\\ Seal Date DRAINAGE AREAS ' 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so,number of low density drainage areas 0 . Is all/part of this project subject to previous rule • 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Bayfilter 5 Total drainage area(sq ft) 378318 184258 6 Onsite drainage area(sq ft) k 378318 184258 7 Offsite drainage area(sq ft) 0 0 8 Total BUA in project(sq ft) 175272 sf 169537 sf _ New BUA on subdivided lots(subject to permitting) 9 (sq ft) sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 140569 sf 134834 sf 11 Offsite BUA(sq ft) sf sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) 117302 sf 111567 sf -Sidewalk(sq ft) 14494 sf 14494 sf -Roof(sq ft) 8773 sf 8773 sf -Roadway(sq ft) -Future(sq ft) _(_ -Other,please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 34703 sf 34703 sf 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 67359 sf 67359 sf 18 Percent BUA 10% 18% 19 Design storm(inches) 1.0 in 20 Design volume of SCM(cu ft) 4678 cf 21 Calculation method for design volume 1"Volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): We are treating 1.2 Acres of New Impervious Area BAYFILTER I Drainage area number 1 2 Minimum required treatment volume(Cu ft) 3509 cf GENERAL MDC FROMD2H Soso 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? N/A 6 Does the SCM have retaining walls,gabion walls or other engineered N/A side slopes? Are the inlets,outlets,and receiving stream protected from erosion 7 Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? N/A 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with Yes General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes BAYFILTER MDC FROM THE STORM WATER DESIGN MANUAL 18 If Volume Design is used,what is the volume from the drainage area 3509 cf (cubic feet)? 19 Is an upstream detention used? Yes 20 Volume of the upslope detention system(cubic feet) 4678 cf 21 Percent of the design volume contained in the upslope detention 133% system(%) 22 If Rate Based Sizing is used,for 1 inch or 1.5 inch(Coastal areas). Water Quality flow rate for drainage area(cfs) 23 Number of cartridges 5 24 Cartridge height(inches) 20 in 25 SHWT elevation(fmsl) 26 Elevation of bottom of BayFilter vault(fmsl) 1202.83 27 Clearance from the SHWT(feet) 28 BayFilter Media Flow Rate(GPM/ft2 of Media Surface) 1 gpm/sf 29 Does the system includes a sediment sump? Yes 30 If yes,the diameter of the sump(feet) 5 ft 31 If yes,the depth of the sump(feet) 2 ft 32 Time to drain the sump(hours) 1 hrs 33 Time to drain the BayFilter(hours) 4 hrs 34 Is an off-line flow splitting device used? Yes ° 35 Type of media used(EMC or GAC-metals) GAC-Metals 36 Will maintenance be performed by Certified Maintenance Providers Yes per instructions? ADDITIONAL INFORMATION 37 Please use this space to provide any additional information about the BayFilter system(s): Line#28 Bayfilter Media Flow Rate is 0.50 gpm/sf; Line 29-32:Sump is provided in the inlet manhole at the isolator row.