Loading...
HomeMy WebLinkAboutSW3240204_Supplement-EZ Form_20240402 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Grassy Branch WRF Expansion 2 Project Area(ac) 1.4 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.48 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 _ 12 'Bioretention Cell I _ 0 _ _ 13 Wet Pond I _ 0 _ 14 Stormwater Wetland _ 0 15 Permeable Pavement _ _ 0 16 Sand Filter _ 0 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale I 0 _ 22 Dry Pond 0 _ _ 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: 1 _ Michael Parker,P.E. 28 Organization: I Hazen and Sawyer 29 Street address: 9101 Southern Pine Boulevard,Suite 250 30 City,State,Zip: Charlotte,NC 28273 31 Phone number(s): (704)940-8910 32 Email: mparker@hazenandsawyer.com Certification Statement I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the Information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Desajner CARp�i (-(6 ��F�SSlpi9<ti ( n� SEAL EpL S jnalure of Designer 26432 �' FNGINE.�Q` 4� y4FCD. 10"' � 1 LI P.bV-LI Seal Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 2 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 LD 2 Dispersed flow& Dispersed flow& 4 Type of SCM vegetated swales Dispersed flow vegetated swales 5 Total drainage area(sq ft) 60,984 17,424 43,560 6 Onsite drainage area(sq ft) 60,984 17,424 43,560 7 Offsite drainage area(sq ft) n/a n/a n/a 8 Total BUA in project(sq ft) 22715 sf 6415 sf 16300 sf New BUA on subdivided lots(subject to 9 permitting)(sq ft) n/a n/a n/a New BUA not on subdivided lots(subject to 10 permitting)(sf) 9470 sf 915 sf 8555 sf 11 Offsite BUA(sq ft) n/a n/a n/a 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) sf sf sf -Sidewalk(sq ft) sf sf sf -Roof(sq ft) 2315 sf 300 sf 2015 sf -Roadway(sq ft) 7155 sf 615 sf 6540 sf -Future(sq ft) sf sf sf -Other,please specify in the comment box below(sq ft) sf sf sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) sf sf sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf sf sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) 13245 sf 5500 sf 7745 sf 16 Existing BUA that is already permitted(sq ft) sf sf sf 17 Existing BUA that will be removed(sq ft) sf sf sf 18 Percent BUA 7% 23% 19% 19 Design storm(inches) 7.5 in 7.5 in 7.5 in 20 Design volume of SCM(cu ft) n/a n/a n/a 21 Calculation method for design volume n/a n/a n/a ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): The Grassy Branch WRF property boundary is less than 0.001%of the total contributing drainage area according to StreamStats(Appendix D).Due to the significant difference,offsite drainage was not considered in the BUA table(Drawing C6).Percent BUA includes all BUA that will be on site after constructinn is cmmnlated LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 4.7 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) n/a 8 Bottom width of curb outlet swale(s)(feet) n/a 9 Maximum side slope of curb outlet swale(s)(H:V) n/a 10 Minimum length of curb outlet swale(s)(feet) n/a 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: A permanent conveyance swale has been designed to convey on-site and off-site runoff to the receiving stream.In general,the project drainage patterns have been designed to mimic the existing drainage patterns.The site has been designed to use natural conveyances in lieu of storm drainage curb and gutter.Please refer to Appendix C for supporting calculations for the permanent conveyance swale.The drainage area size and peak flow were developed using USGS StreamStats,and backchecked using available topographic and aerial imagery. Drainage Pervious Swale BUA Q Slope Venow Va«�ai Flow depth Area area (ac) (cfs) (%) (fps) (fps) (ft) (ac) (ac) 1 18.70 1.67 17.03 0.39 27.00 1.70 16.00 4.70 1.40 2 — — — - 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 2