Loading...
HomeMy WebLinkAboutSW6231107_Supplement-EZ Form_20240314 SUPPLEMENT-EZ COVER PAGE PROJECT INFORMATION • 1 Project Name Kingston Village 2 Project Area(ac) 36.69 _3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 _5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? NO COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) N/A 8 Will the vegetated setback remain vegetated? WA 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? WA 10 Is strearnbank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 'Infiltration System 12 Bioretention Cell 13 Wet Pond 2 14 Stonnwater Wetland 15 Permeable Pavement 16 ;Sand Filter _ 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 !,Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: David Despeaux 28 Organization: Moorman,Kizer&Reitzel,Inc. 29 •Street address: 115 Broadfoot Avenue 30 !City,State,Zip: _ Fayetteville,NC 28305 31 Phone number(s): 910-484-5191 32 'Email: ddespeaux©mkrinc.com Certification Statement: I certrfy,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision that the information provided in the form is.to the best of my knowledge and belief.true,accurate,and complete:and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here Designer ������t 1 I t r u r I I l r l 7/ • • .�vvvQvyvCARSSIO OL /// SEAL Signa ur of Designer 031116 • O ••••FNGINV--'•''• Q��.�� 9`'�c. DE ,\\\\\ 3/i y10z4/ 77iiillSblayI111\\\� Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 2 3 Does this project have low density areas? No 4 If so,number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No CLICK TO LOAD FORM WET POND 1 Drainage area number POND A I POND B 1 2 Minimum required treatment volume(Cu ft) 39853 cf t 6341 cf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V)? 3H:1V 3H:1V 6 Does the SCM have retaining walls,gabion walls or other Yes Yes engineered side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes i(10-year storm)? 81 Is there an overflow or bypass for inflow volume in excess of the Yes Yes design volume? 9,What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? Yes Yes 11 iDoes the maintenance access comply with General MDC(8)? Yes Yes 121 Does the drainage easement comply with General MDC(9)? Yes Yes 131H the SCM Is on a single family lot,does(will?)the plat comply with N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes _ 16'Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes WET POND MDC FROM 02H.1053 18 Sizing method used SA/DA SA/DA 19 Has a stage/storage table been provided in the calculations? Yes Yes 20 Elevation of the excavated main pool depth(bottom of sediment 239.50 240.00 removal)(fmsl) 21iElevation of the main pool bottom(top of sediment removal)(fmsl) 240.00 240.50 22 Elevation of the bottom of the vegetated shelf(fmsl) 244.50 248.00 231Elevation of the permanent pool(fmsl) 245.00 248.50 241 Elevation of the top of the vegetated shelf(fmsl) 245.50 249.00 25-Eevation of the tempora y pool(fmsl) 246.57 249.76 26iSurface area of the main permanent pool(square feet) 25834 4702 271 Volume of the main permanent pool(cubic feet) 106290 cf 15546 cf 28 Average depth of the main pool(feet) 4.11 ft 3.31 ft 29 Average depth equation used Equation 2 Equation 2 30 if using equation 3,main pool perimeter(feet) 31 If using equation 3,width of submerged veg.shelf(feet) 32 Volume of the forebay(cubic feet) 19221 d 2639 of 33 Is this 15-20%of the volume In the main pool? Yes Yes 34 Clean-out depth for forebay(inches) 6 INCHES 6 INCHES 35 Design volume of SCM(cu ft) 39853 cf 6341 cf 36 Is the outlet an orifice or a weir? Orifice Orifice 37 If orifice,orifice diameter(inches) 4'FOR TRT.VOL. 1.5"&6'FOR TRT.VOL. _38 If weir,weir height(inches) 39 If weir.weir length(inches) 40 Drawdown time for the temporary pool(days) 4.7 2.3 41 Are the inlets)and outlet located in a manner that avoids short- Yes Yes circuiting? 42 Are berms or baffles provided to improve the flow path? Yes Yes 43 Depth of forebay at entrance(Inches) 69 in 81 In 44 Depth of forebay at exit(inches) 66 in 78 in 45,Does water flow out of the forebay in a non-erosive manner? Yes Yes 46`W idth of the vegetated shelf(feet) 6 ft 6 ft 47'Slope of vegetated shelf(H:V) 6H:1 V 6H:1 V i Does the orifice drawdown from below the top surface of the Yes Yes 481 permanent pool? 49 Does the pond minimize impacts to the receiving channel from the 1- Yes Yes yr,24-hr storm? Are fountains proposed?(If Y,please provide documentation that 50No No MDC(9)is met.) 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes 52 Are the dam and embankment planted In non-clumping turf grass? Yes Yes 53 Species of turf that will be used on the dam and embankment �� & Bermuda& Centipede Centipede 54 Has a planting plan been provided for the vegetated shelf? Yes Yes ADDITIONAL INFORMATION _ Please use this space to provide any additional information about 55 the wet pond(s): 2