Loading...
HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (18) SERENTIY SCM#13 Drainage Area: 978,807 sf 22.47 ac Impervious Area: 483,779 sf 11.11 ac %Impervious: 49.4% 1 inch Storm Event: Rv=0.05+0.009 I Rv=runoff coefficient I=percent impervious Rv= 0.4948 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required: 40,362 cf Volume provided: 46650 cf Average depth: 4.1 ft SA/DA ratio 1.39 Required surface area: 13605 sf Surface area provided: 16644 sf