Loading...
HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (6) SERENTIY 3,4&5 SCM 12 Antiflotation Calculation Input Data Safety Factor: 1.5 Top Width of Riser(ft) 5 Top Length of Riser(ft) 4 Thickness of Riser(ft) 0.5 Thickness of Bottom of Riser(ft) 0.5 Top of Riser(ft) 318 Invert of Riser(ft) 307.29 Volume of Riser(cf) 95.68 Unit Weight Of Concrete(lb/cf) 150 Unit Weight of Water(lb/cf) 62.4 Block Height(ft) 2 Block Width(ft) 5 Block Length(ft) 4 Output Fw(Uplift Force,lb) 13366.08 Fc(Weight of Concrete,lb) 20352 Design Volume(cf) 135.68 Design Safety Factor 1.52 Volume OK