Loading...
HomeMy WebLinkAboutSW3230701_Supplement-EZ Form_20240223 ,SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Stewart's Grove 2 Project Area(ac) 18 41 3 Coastal Wetland Area(ac) 0 _ 4 Surface Water Area(ac) 0 58 5 _Is this p ject High or Low Density? High _, . _ _ _ 8 Does this project use an off-site SCM? No COMPLIANCE WITH1.02H'.1003(4) 7 Width of vegetated setbacks provided(feet)_ _ 50' 8 i Will the vegetated setback remain vegetated? _ Yes 9 `If BUA is ppposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? NIA 10 Its streambank stabilization proposed on this project? No ;NUMBER AND TYPE OF SCMs: _11 Infiltration System 0 12 Biorelention Cell 0 _ 13 Wet Pond 0 14 LStormwater Wetland 0 15 'Permeable Pavement 0 16 'Sand Filter 2 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 _ 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale 0 _22 Day Pond 2 23 StormFiller ` 0 24 Silva Cell 0 25 Bayfilter - 26 Filterra 0 FORM LOADED DESIGNER CERTIFICATION • 27 Name and Title: Jack McFadden PE 28 Organization: Thomas&Hutton 29 Street address: 1020 Euclid Ave 30 City,State,Zip. Charlotte NC 28203 31 Phone numberO: (980)201-5505 32 Email mcfadden j@tandh corn CerJfi atlor 5:a!ement I certify under penalty of taw that this Supplement•EZ form and all supporting Information were prepared under my direction or supervision;that the Information provided In the form is,to the best of my knowledge and belief true,accurate,and complete,and that the engineering plans specifications operation and maintenance agreements and other supporting Information are consistent with the information provided here peslenvr CAR i 2.•�O Gti'ti • •4 SEAL r 7eslgner : 049941 - •'• GIINES•• + ..MCF P► \% 2 ' J Ze) / T, V Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs _ 2 3 Does this project have low density areas? _ No 4 If so,number of low density drainage areas _ Is all/part of this project subject to previous rule 5 versions? No CLICK TO LOAD FORM SAND FILTER 1 Drainage area number 4 5 I 2 Minimum required treatment volume(Cu ft) 14776 sf 1729 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yen Ye:, 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V)? 3:1 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with General MDC(8)? Yes Yes 12 Does the drainage easement comply with General MDC(9)? Yes Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 19 Type of sand filter(open or closed) Closed Closed 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(fmsl) 534 537 22 Is this sand filter designed to attenuate peak flows? Yes Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 7200 cf 800 cf 24 Will there be a permanent pool in the sediment chamber? No No 25 Bottom of the sediment chamber(fmsl) 532.50 535.50 26 Area of the sediment chamber(square feet) 3600 sf 400 sf 27 Physical depth of the sediment chamber(inches) 18 in 18 in 28 Ponding depth in the sediment chamber,above any permanent pool 24 in 24 in (inches) 29 Elevation of top of weir between chambers(fmsl) 539.5 539.5 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 7800 cf 1000 cf 31 Bottom of the sand chamber(fmsl) 532.50 535.50 32 Area of the sand chamber(square feet) 3900 sf 500 sf 33 Physical depth of the sand chamber(inches) 18 in 18 in 34 Ponding depth in the sand chamber,above the sand surface 24 in 24 in (inches) 35 Elevation of the bypass device(fmsl) 539.5 539.5 36 Type of bypass device Emergency Emergency Spilllway Spillway 37 Mechanism for distributing flow over the sand surface Natural Flow Natural Flow 38 Sand specification for sand chamber ASTM C33 or ASTM C33 or equivalent equivalent 39 Depth above underdrain pipe(inches) 18 in 18 in 40 Will the media be maintained to drain at least two inches per hour at Yes Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes Yes underdrain line? 42 Will clean-out pipes be capped? Yes Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): 20)Filter installation type to be determined by contractor 2 DRY POND 1 Drainage area number 4 5 2 Minimum required treatment volume(cu ft) 14776 sf 14776 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? No No 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V)? 3:1 3:1 6 Does the SCM have retaining walls,gabion walls or other No No engineered side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? N/A N/A 11 Does the maintenance access comply with General MDC(8)? Yes Yes 12 Does the drainage easement comply with General MDC(9)? Yes Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes 16 Does the SCM follow the device specific MDC? No No 17 Was the SCM designed by an NC licensed professional? Yes Yes DRY POND MDC FROM 02H.1062 18 SHWT elevation(fmsl) 19 Elevation of the bottom of the dry pond(fmsl) 534 537 20 Distance from bottom to SHWT(feet) 21 Elevation of the temporary pool during the design storm(feet) 539.54 ft 539.31 ft 22 Ponding depth of the design storm(feet) 5.54 ft 2.31 ft 23 Will the dry pond be uniformly graded to flow toward the outlet? No No 24 Is a low flow channel being provided? No No 25 Are the inlet(s)and outlet located in a manner that avoids short- Yes Yes circuiting? 26 Will berms or baffles be provided to increase the flow path? No No 27 What method of pretreatment will be provided? Forebay Forebay 28 Design volume of SCM(cu ft) 71,882.91 11,148.33 29 Diameter of drawdown orifice(in) 6 in 6 in 30 Drawdown time for the temporary pool(hours) _ N/A N/A 31 Does the pond minimize impacts to the receiving channel from the 1- Yes Yes yr,24-hr storm? 32 Is there a small permanent pool near the orifice to prevent clogging? No No 33 Will the outlet be designed to prevent clogging? Yes Yes 34 Are the dam and embankment planted in non-clumping turf grass? Yes Yes 35 Species of turf that will be used on the dam and embankment fescue/centipede fescue/centipede blend _ blend 36 Will trees and shrubs be prevented from growing on the dam and Yes Yes embankment? ADDITIONAL INFORMATION Please use this space to provide any additional information about the 37 dry pond(s): In this design,both dry ponds will be acting as secondary SCMs in direct connection with one of the two sand filters,which will be acting as the design's primary SCM 16)MDC 8,we do not have a small permanent pool for the above reasoning. 2