HomeMy WebLinkAboutSW1230601_Response To Comments_20240213 ULICK ENGINEERING,LLC February 9, 2024 Jim Farkas North Carolina Department Environmental Quality 512 North Salisbury Street Raleigh, NC 27699 Office: (919) 707-9200 Subject: Asheville Regional Airport—South Parking Lot Review Comments dated January 23, 2024 (via email) Stormwater Permit No. SW1230601 Dear Mr. Farkas, Thank you for providing comments on the Asheville Regional Airport South Parking Lot project. Please see our responses to your comments below. Initial Plans Dated: April 2023 Revision 1 Plans Dated: October 2023 Revision 2 Plans Dated: February 2024 1. Prior Comment 1.b. "...Delineate the on-site surface water area. This item is required per Section V1.8.h. and per 15A NCAC 02H .1042(2)(g)'""" .. Some of the on-site surface waters do not appear to be shown on the plans (see attached photo). Please include these surface waters on the plans and in the Application and Supplement-EZ Form,revising as needed. Per the provided plans, there appears to be an impact to the surface waters (along the parking area access road). Please verify whether or not a 404/401 permit is required for this impact and revise Section II,4 of the Application as needed. Correction: The additional surface waters (+0.06ac) are now included on plan sheets SW-01 and SW-05,section IV.6 of the Application, and Line 4 on the Cover Page of the Supplemental- EZ form. 2. Prior Comment 1.c. z the required vegetated setbacks from the surface waters. This item is reauired ner Section V1.8.p. and per 15A NCAC 02H.1042(2)(g)(iiL Please show the extents of this vegetated setback on plan sheet SW-05.There appears to be BUA that is located within this vegetated setback. If the BUA located within the setback is seeking an exemption per 15A NCAC 02H .1003(4)(c)/(d) or 15A NCAC 02H .1017(12), please indicate the applicable exemption. If the BUA does not meet one of these exemptions, it will need to be located outside of the vegetated setback. Correction: The SW-01 sheet view has been adjusted to show the encroachment. This vegetated stream buffer encroachment is only 70 square feet and will qualify as exemption under 15A NCAC 02H.1003(4)(d)I: "Publicly funded linear projects such as roads, greenways, and sidewalks". See notes added to the top middle of plan sheet SW-01. ASHEVILLE REGIONAL AIRPORT SOUTH PARKING LOT-NCDEMLR COMMENTS AND RESPONSES ULICK ENGINEERING,LLC 3. Prior Comment 2.b. "...Clarify the amount of BUA draining to the proposed SCM... Please revise as needed." Per the Application and Supplement-EZ form, the total amount of BUA draining to the SCM is shown as 257,530 sf(5.91 ac). Per the plans(plan sheet SW-06) and stormwater report the total amount of BUA draining to the SCM is shown as 5.43 ac. Please revise as needed. Correction:The proposed SCM now accounts for all of the proposed BUA of the project,5.48ac or 238,734sf. Section 10 of the Application and Line 10 of the Drainage Areas page in the Supplemental EZ form now show this value. Plan sheet SW-06 now shoes 6.06 acres in the Post-Construction Impervious column, which equals the existing BUA (0.58ac) plus the proposed BUA(5.48ac). The tables in the storm water report have also been updated to reflect this. Per the Provided Design Volume and Peak Flow Rates tables on sheet SW-01, the Dry Pond is adequately sized to handle all of the proposed BUA. 4. Prior Comment 10.a.iii. Please correct the follo.,;. ' ICCIIof Iuith tho Cnnnlr---• '' '-rm I inc- n n n n. `rncie,or thoco ;toms."See earlier comment, there appears to be BUA proposed within the vegetated setback. Correction:On the Supplemental EZ cover page Line 8 now lists "No"and Line 9 now lists "Yes" as a small sliver of the setback will now be paved (BUA is proposed in the setback). This vegetated stream buffer encroachment is only 70 square feet and will qualify as exemption under 15A NCAC 02H.1003(4)(d)I: "Publicly funded linear projects such as roads, greenways, and sidewalks" 5. Prior Comment 10.c.i. ,:orrect the following issues with the Supplement-EZ Form... Dry Pond Page... Revise if needed in accordance with other comments." a. Line 18—Per the narrative,the SHWT elevation is at approximately 2079.3'(2080.0' shown). Please revise. Correction:Line 18 has been revised to 2079.3. b. Line 20—Per the narrative,the SHWT elevation is at approximately 2079.3'and the bottom of the dry pond is at elevation 2080.5'which results in a distance of 1.2' (0.5' shown). Please revise. Correction:Line 20 has been revised to 1.2ft. c. Line 21—The temporary pool elevation is set by the invert of the lowest bypass(weir at elevation 2084.5'). Please revise. Correction:Line 21 has been revised to 2084.5. d. Line 22—The ponding depth is the distance from the bottom of the SCM (Line 19)to the temporary pool elevation (Line 21). Please revise. Correction:Line 22 has been revised to 4.0ft. e. Line 29—Per the design,the drawdown orifice diameter is 2.5" (3" is shown). Please revise. Correction:Line 29 has been revised to 2.5". ASHEVILLE REGIONAL AIRPORT SOUTH PARKING LOT-NCDEMLR COMMENTS AND RESPONSES ULICK ENGINEERING, LLC f. NOTE: Some of these cells do not allow for decimal numbers to be entered. If this is the case, please indicate the actual value for these lines in the additional information section (Line 37). Correction: Decimals are now shown correctly on the Dry Pond page of the Supplemental EZ form. 6. Please correct the following issues with the Supplement-EZ Form: a. Cover Page, Line 2—The project area does not include the surface water area (this value should correspond to Section IV,7 of the Application). Please revise. Correction: This number in the Supplemental EZ now includes surface waters and matches Section IV, 7 of the Application (10.79ac0. b. Drainage Area Page, Entire Site Column, Lines 5 &6—These items should correspond to the project area (these values should correspond to Section IV,7 of the Application). Please revise. Correction: These lines have been updated to list the project area that matches the Application. 470,012sf=10.79ac. c. Drainage Area Page, Entire Site Column, Line 18—Please provide this value (this value should correspond to Section IV,8 of the Application). Please revise. Correction: This line now shows 56.2% that matches Section 8 of the Application. 7. Provide PDFs of all revisions,2 hardcopies of revised plan sheets, 1 hardcopy of other documents, and a response to comments letter briefly describing how the comments have been addressed. a. PDFs must be uploaded using the form at: https://edocs.deq.nc.gov/Forms/SW-Supplemental-Upload b. Hard copies must be mailed or delivered to the following address: i. For FedEx/UPS: Jim Farkas 512 N. Salisbury Street, Office 640M Raleigh, NC 27604 ii. For USPS: Jim Farkas 1612 Mail Service Center Raleigh, NC 27699-1612 iii. Hand Delivery: Please reach out to me prior to hand delivering a submission to make sure that I (or someone else in my group)will be able to receive the submission. Do not leave the package in the foyer with the security guard. NOTE: Hard copies should not be sent to a Regional Office. Doing so will delay the review process and the submission package may be lost while being sent from the Regional Office to me in the Central Office. ASHEVILLE REGIONAL AIRPORT SOUTH PARKING LOT-NCDEMLR COMMENTS AND RESPONSES