Loading...
HomeMy WebLinkAboutSW6231112_Supplement-EZ Form_20240117 SUPPLEMENT-EZ COVER PAGE FORMS LOADED IROJECT INFORMATION ev,1 .Project Name .a ,.. Brayden Preserve Subdivision 2 Project Area(ac) 69.93 I 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 1 5 Is this project High or Low Density? Low 6 Does this project use an off site SCM? No :OMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes . / 9 ilf BUA is proposed in the setback,does it meet NCAC 02H 1003(4)(c-d)? N/A I 10 Is streambank stabilization proposed on this project? No (UMBER AND TYPE OF SCMs: 11 Infiltration System l 12 Bioretention Cell 1 13 Wet Pond 14 Stormwater Wetland 15 i Permeable Pavement 16 ;Sand Filter 17 Rainwater Harvesting(RWH) i 18 Green Roof ! a 19 ;Level Spreader-Filter Strip(LS-FS) • 20 !Disconnected Impervious Surface(DIS) t 21 Treatment Swale l 22 'Dry Pond I 23 StormFilter i 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 1 27 iName and Title: C. Scott Brown,PE t 28 Organization: 4D Site Solutions, Inc 29 Street address: 409 Chicago Drive-Ste 112 i 30 City,State,Zip: Fayetteville, NC 28306 31 Phone number(s): 910-426-6777 32 ;Email sbrown@4dsitesolutions.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 0`01111 I,1/,, A40 Iv Al e)MI ;A-1L _ Signature o Designer SEA 027452 n ••.F�lGINE�• �?. '',sc• e�°,'0_Zt(-Z3 [0-24'- 23 o-rr Seal Date DRAINAGE AREAS ± f is this a high density project? ; No 2 ; If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes : 4 If so, number of low density drainage areas : 1 Is all/part of this project subject to previous rule ; } 5 :versions? , No . .. FORMS LOADED RAINAGE AREA INFORMATION ' Entire Site 0 LD 1 t 1 4 ;Type of SCM t Low Density 0: Low Density t 5.. L 1Total drainage area(sq ft) t;, 3,046,153 1 3,046,153 J; 6 af:Onsite drainage area(sq ft) 3,046,163 t 3,046,153 t ; ',; 7 ;Offsite drainage area(sq ft) , 0 . 0 „ 8 `;Total BUA in project(sq ft) ; ) 526876 sf ) 526876 sf -44. New BUA on subdivided lots(subject to 9 .;;permitting)(sq if 408000 sf 1 408000 sf New BUA not on subdivided lots(subject to ; 1 0 permitting)(sf) 118876 sf ; 118876 sf li ;Offsite BUA(sq ft) t sf , t t 12 ;Breakdown of new BUA not on subdivided lots: -Parking(sq ft) t t t t -Sidewalk(sq ft) t t -Roof(sq ft) t t t ' -Roadway(sq ft 118876 sf t 118876 sf 4 1 * -Future(sq ft) -Other, please specify in the comment box t t below Isq_ft); t i New infiltrating permeable pavement on 1 t) 4 4 13 Lsubdivided lots(sq ft) t , t ; . 5 New infiltrating permeable pavement not on A A" 14 Isubdivided lots(sq ft) ) ; t 'Existing BUA that will remain(not subject to ii: 15 !.PffPlitting.).(sq 1 1 16 i Existing BUA that is already permitted(sq ft) ; t 17 Existing BUA that will be removed(sq ft) i .. t 18 1Percent BUA ) 17% t 17% t 19LDesign storm(inches) 1 9, t 20 i Design volume of SCM(cu ft) t 1 ; 21 ;Calculation method for design volume ADDITIONAL INFORMATION , . Please use this space to provide any additional information about the 1 22 idrainage area(s): „ .. t ; LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 ;Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 ) 3 Haas the use of piping been project maximize mrinim zed ped flow d minr 1003(2)(c)�annelization of flow? Yes s 4 Side slopes of the vegetated conveyances(H.V) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 5 f 6 ,Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) N/A 8 Bottom width of curb outlet swale(s)(feet) N/A 9 Maximum side slope of curb outlet swale(s)(H:V) N/A 10 ' Minimum length of curb outlet swale(s)(feet) N/A t 11 Are treatment swales used instead of curb outlet swales? 12 .Is stormwater released at the edge of the setback as dispersed flow? N/A " 13 Have stormwater outlets been designed to prevent downslope erosion? Yes a 14 ,Are variations to rule.1003 proposed? No a ADDITIONAL INFORMATION 4 15 Please use this space to provide any additional information about this low density project: Drainage f BUA Pervious Swale Q Slope Va.,,, V.cm.i Flow depth # Area (ac) area C Tact (acl (cfs) (%) (fps) (fps) (ft) 1 0.14 0.03 0.11 0.45 0.48 9.00 5.00 2.71 0.17 2 0.38 0.09 0.29 0.45 1.32 5.00 5.00 2.79 0.32 3 0.74 0.17 0.57 0.45 2.55 7 20 5.00 4.35 0.37 4 0.58 0.13 0.44 0.45 2.00 7.20 5.00 3.99 0.33 5 0.82 0.19 0.63 0.45 2.82 2.30 5.00 2.31 0.56 6 3.32 0.77 2.55 0.45 11.47 2.30 5.00 3.78 0.93 7 _ 1.82 0.42 1.40 0.45 6.31 1.60 5.00 2.48 0.84 8 5.27 _ 1.22 4.06 0.45 18.25 0.84 2.00 1.52 1.69 9 0.37 0.09 0.29 0.45 1.29 4.00 5.00 2.43 0.35 10 0.68 0.16 0.53 0.45 2.37 4.00 5.00 3.01 0.44 11 1.14 0.26 0.88 0.45 3.96 5.90 5.00 4.16 0.32 12 1.62 0.37 1.25 0.45 5.60 2.60 5.00 3.16 0.69 13 4.02 0 93 3 09 0 45 13 91 2.60 5.00 4.34 0-95 14 0.06 0.01 0.05 0.45 0.21 5.00 5.00 1.43 0.15 16 1.78 0.41 137 0.45 6.16 5.00 5.00 4.79 0.58 16 1.40 0.32 1.08 0.45 4.86 1.70 5.00 2.35 0.75 17 7.03 1.62 5.41 0.45 24.32 1.00 5.00 2.99 1.35 18 2.05 0.47 1.57 0.45 7.08 5,00 5,00 3.87 0.70 19 0.38 0.09 0 30 0.45 1.33 5.00 5.00 2.79 0.32 20 1.13 0.26 0.87 0.45 3.92 0.57 5.00 1.15 0.99 21 2.18 0.50 1.68 0.45 7.55 2.90 5.00 3.74 0.74 22 0.95 0.15 0.81 0.40 2.93 1.60 5.00 1.90 0.64 23 10.77 1.66 9.11 0.40 33.14 1.60 5.00 4.42 1.50 24 0.88 0.14 0.74 0.40 2.70 4.00 ' 5.00 , 3.15 0.46 25 0.41 0.06 0.34 0.40 1.25 2.00 5.00 1.60 0.43 26 3.13 0.48 2.65 0.40 9.64 5.40 5.00 4.50 0.76 27 0.38 0.06 0.32 0.40 1.16 5.40 5.00 2.78 0.30 28 4.01 0.62 3.39 0.40 12.33 2.30 5.00 3.79 0.76 29 0.55 0.08 0.47 0.40 1.70 5.50 5.00 3.22 0.34 30 3.42 0.53 2.89 0.40 10.51 5.50 5.00 4.70 0.65 Low Density(contnued)