Loading...
HomeMy WebLinkAboutSW3181002_Supplement-EZ Form_20240112 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Cottages West/Cottages at Indian Trail 2 Project Area(ac) 12.67 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 2 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Nicholas T.Vesely,PE(Engineer) 28 Organization: V3 Southeast 29 Street address: 3700 South Boulevard,Suite 200 30 City,State,Zip: Charlotte,NC 28209 31 Phone number(s): 704.920.2883 32 Email: Nvesely@V3Co.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 0111111 SEAL = Signature of Designer : 047011 r' O•.eA, EEC ••dfki '''''iii�11111�1•1````NNN I/I I/21 1.11.24 Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs _ 2 3 Does this project have low density areas? _ No 4 If so,number of low density drainage areas _ 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 4 Type of SCM _ Sand Filter Sand Filter _ 5 Total drainage area(sq ft) 651480 _ 291422 360058 6 Onsite drainage area(sq ft) 434680 155496 279184 7 Offsite drainage area(sq ft) 216800 135926 80874 8 Total BUA in project(sq ft) 433706 sf 196664 sf 237042 sf New BUA on subdivided lots(subject to 9 permitting)(sq ft) 173897 sf 44721 sf 129176 sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 43009 sf 16017 sf 26992 sf 11 Offsite BUA(sq ft) _ 216800 sf _ 135926 sf 80874 sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) -Roof(sq ft) -Roadway(sq ft) 43009 sf 16017 sf 26992 sf -Future(sq ft) -Other,please specify in the comment box below(sq ft) 874 sf 874 sf sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) -New infiltrating permeable pavement not on 14 subdivided lots(sq ft) - - Existing BUA that will remain(not subject to 15 permitting)(sq ft) N/A - - 16 Existing BUA that is already permitted(sq ft) - - 17 Existing BUA that will be removed(sq ft) - - 18 Percent BUA _ 41% _ 39% 56% 19 Design storm(inches) 1.0 in 1.0 in 20 Design volume of SCM(cu ft) 14674 cf 21489 cf 21 ,Calculation method for design volume SCS TR-20 SCS TR-20 ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): _ The drainage areas do not vary greatly from the previous design,however. The 874 sf above indicates the amount of roadway/sidewalk that is bypassed around the site. SAND FILTER 1 Drainage area number 1 2 I 2 Minimum required treatment volume(Cu ft) 11967 sf 14459 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yen Ycn 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V)? 3:1 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No Yes side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with General MDC(8)? Yes Yes 12 Does the drainage easement comply with General MDC(9)? Yes Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM desi ned b an NC licensed rofessional? Yes Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 658 653.5 19 Type of sand filter(open or closed) Open Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(fmsl) 22 Is this sand filter designed to attenuate peak flows? No I No Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) ' 7467 cf 12380 cf 24 Will there be a permanent pool in the sediment chamber? No No 25 Bottom of the sediment chamber(fmsl) 668.00 657.00 26 Area of the sediment chamber(square feet) 1860 sf 4359 sf 27 Physical depth of the sediment chamber(inches) 36 in 30 in 28 Ponding depth in the sediment chamber,above any permanent pool 36 in 30 in (inches) 29 Elevation of top of weir between chambers(fmsl) 671 659.5 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 7207 cf 9109 cf 31 Bottom of the sand chamber(fmsl) 668.00 657.00 32 Area of the sand chamber(square feet) 1860 sf 3284 sf 33 Physical depth of the sand chamber(inches) 36 in 30 in 34 Ponding depth in the sand chamber,above the sand surface 36 in 30 in (inches) 35 Elevation of the bypass device(fmsl) 671 659.5 36 Type of bypass device Outlet Control Outlet Control Structure Structure 37 Mechanism for distributing flow over the sand surface "'„may"' Cap"'`.ay" 38 Sand specification for sand chamber _ ASTM C-33 ASTM C-33 39 Depth above underdrain pipe(inches) 12 in 12 in 40 Will the media be maintained to drain at least two inches per hour at Yes Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes Yes underdrain line? 42 Will clean-out pipes be capped? Yes Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): 2