Loading...
HomeMy WebLinkAboutSW6230604_Response To Comments_20231218 FOX FIELD FARMS —SW6230604 ADDITIONAL INFORMATION—REVIEW LETTER DATED 12-14-2023 COMMENT RESPONSE 1. Please confirm that the mail kiosk is accounted for within the built upon area. REVISED/NOTED 2. The site and grading plans show existing BUA in lots 7, 9, and 10. Please clarify that these will be removed, or account for it as "existing BUA" in the Application and Supplement-EZ. REVISED/NOTED 3. Please correct the drainage area information entered into the table in Section IV, 10 of the Application. Per the guidance provided in Section IV, 9 of the Application, the "drainage area" of a low-density project is equal to the project area. The project area excludes the surface water area. Total project area shall exclude the areas below the Normal High Water Line (NHWL) per 15A NCAC 02H .1003 (1) (c) (1). REVISED 4. The % Impervious area is calculated by dividing the proposed impervious area by the total drainage area. 945,174SF/4100801 SF=23.0%<23.2%. REVISED 5. Supplement-EZ, Cover, Line 2—The project area provided in this line should match the project area provided in the Application Section IV, 7. REVISED 6. Supplement-EZ, Cover, Line 4—The surface water area provided in this line should match the project area provided in the Application Section IV, 6. REVISED 7. Supplement-EZ, Low Density, Line 15 —There appears to be a typo, as information for swales#45-54 were not provided. REVISED 8. At the intersections, the provided grading indicates that the side slopes of the vegetated conveyances may exceed 3:1. All vegetated conveyances used in a low-density project must have side slopes that are 3:1 or flatter(per 15A NCAC 02H .1003(2)(c)). Steeper side slopes can be used if it is demonstrated, via on-site soil tests & engineering calculations that the vegetation will remain stable in perpetuity. REVISED/NOTE ADDED 9. Per the calculations provided on Sheet C5.1, the velocity of the roadside ditch 24 and swales 32 and 33 exceed the allowable velocity. This would result in erosion during the 10-year storm. Per 15A NCAC 02H .1003 (2) (c) (ii), the conveyance shall be designed so that it does not erode during the peak flow from the10-year storm. REVISED 10. It is recommended to not include temporary erosion control measures on the plans for this permit application, as only permanent conditions are considered. The hatch for the skimmer basin is clear on the electronic copies but appears as solid black boxes on the hard copies provided, which makes verification of curb outlet requirements impossible on the hard copies of the plans. REVISED 11. The curb outlet swale's cross-section shall be trapezoidal with a minimum bottom width of two feet per 15A NCAC 02H .1003 (2) (d). Swale 37 does not meet this requirement. REVISED