HomeMy WebLinkAboutSW5231001_Supplement-EZ Form_20231008 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name Economy 3 Expansion
2 Project Area(ac) 78.23
3 Coastal Wetland Area(ac) _ 0
4 Surface Water Area(ac) 0
5 Is this project High or Low Density? High
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4)
7 Wdth of vegetated setbacks provided(feet) 50
8 WII the vegetated setback remain vegetated? Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 Infiltration System
12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 _Treatment Swale
22 ,Dry Pond _
23 StormFilter
24 Silva Cell
25 _Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Timothy S.Kennerly,PE
28 Organization: _ Kennerly Engineering&Design,Inc.
29 Street address: 12133 N NC HWY 150,Ste.F
30 City,State,Zip: Wnston-Salem,NC 27127
31 Phone number(s): (336)775-2118
32 Email: timothy.kennerly@kennerlyengineering.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that
the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
\\\\11111111//,
SEAL • — Signature of Designer
29317 :>- ;
:gyp .!VCINEct•••
,tiYS. KE G.\\ `��ZZ/Z3
//l/lllllll\\ Date
DRAINAGE AREAS
1 Is this a high density project? Yes
2 If so,number of drainage areas/SCMs _ 7
3 Does this project have low density areas? _ No
4 If so,number of low density drainage areas _ 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site 1 2 3 4 5
4 Type of SCM SGW SGW SGW SGW SGW
5 Total drainage area(sq ft) 485,694 550,598 265,716 641,203 515,750
6 Onsite drainage area(sq ft) 485,694 550,598 265,716 641,203 515,750
7 Offsite drainage area(sq ft) 0 0
8 Total BUA in project(sq ft) 485694 sf 550598 sf 265716 sf 641203 sf 515750 sf
New BUA on subdivided lots(subject to
9 permitting)(sq ft)
New BUA not on subdivided lots(subject to
10 permitting)(sf) 485694 sf 550598 sf 264716 sf 641203 sf 370695 sf
11 Offsite BUA(sq ft)
12 Breakdown of new BUA not on subdivided lots:
-Parking(sq ft) 485694 sf 550598 sf 264716 sf 641203 sf 370695 sf
-Sidewalk(sq ft)
-Roof(sq ft)
-Roadway(sq ft)
-Future(sq ft)
-Other,please specify in the comment box
below(sq ft)
New infiltrating permeable pavement on
13 subdivided lots(sq ft)
New infiltrating permeable pavement not on
14 subdivided lots(sq ft)
Existing BUA that will remain(not subject to
15 permitting)(sq ft) 145055 sf
16 Existing BUA that is already permitted(sq ft)
17 Existing BUA that will be removed(sq ft)
18 Percent BUA 100% 100% 100% 100% 100%
19 Design storm(inches) 1.0 in 1.0 in 1.0 in 1.0 in 1.0 in
20 Design volume of SCM(cu ft) 251752 cf 256070 cf 126503 cf 368117 cf 249473 cf
21 Calculation method for design volume Total Storage Total Storage I Total Storage Total Storage Total Storage
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
DRAINAGE AREAS
1 Is this a high density project? Yes
2 If so,number of drainage areas/SCMs _ 7
3 Does this project have low density areas? _ No
4 If so,number of low density drainage areas _ 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site 6 7
4 Type of SCM SGW SGW
5 Total drainage area(sq ft) 283,576 665,161
6 Onsite drainage area(sq ft) 283,576 665,161
7 Offsite drainage area(sq ft)
8 Total BUA in project(sq ft) 286576 sf 665161 sf
New BUA on subdivided lots(subject to
9 permitting)(sq ft)
New BUA not on subdivided lots(subject to
10 permitting)(sf) 283576 sf 665161 sf
11 Offsite BUA(sq ft)
12 Breakdown of new BUA not on subdivided lots:
-Parking(sq ft) 283576 sf 665161 sf
-Sidewalk(sq ft)
-Roof(sq ft)
-Roadway(sq ft)
-Future(sq ft)
-Other,please specify in the comment box
below(sq ft)
New infiltrating permeable pavement on
13 subdivided lots(sq ft)
New infiltrating permeable pavement not on
14 subdivided lots(sq ft)
Existing BUA that will remain(not subject to
15 permitting)(sq ft)
16 Existing BUA that is already permitted(sq ft)
17 Existing BUA that will be removed(sq ft)
18 Percent BUA 100% 100%
19 Design storm(inches) 1.0 in 1.0 in
20 Design volume of SCM(cu ft) 114059 cf 233636 cf
21 Calculation method for design volume Total Storage Total Storage
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
SUBMERGED GRAVEL WETLANDS
1 Drainage area number 1
2 Minimum required treatment volume(cu ft) 38451 53589 21036 50762 40830 22450 52689
` GENERAL MDC FROM 02H.1050
3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes Yes Yes Yes Yes Yes
4 Is the SCM located away from contaminated soils? Yes Yes Yes Yes Yes Yes Yes
5 What are the side slopes of the SCM(H:V)? 3:1 3:1 3:1 3:1 3:1 3:1 3:1
6 Does the SCM have retaining walls,gabion walls or other engineered side
slopes? No No No No No No No
7 Are the inlets,outlets,and receiving stream protected from erosion(10-year
storm)? Yes Yes Yes Yes Yes Yes Yes
8 Is there an overflow or bypass for inflow volume in excess of the design
volume? Yes Yes Yes Yes Yes Yes Yes
Cleanout in Cleanout in Cleanout in Cleanout in Cleanout in Cleanout in Cleanout in
9 control control control control control control control
What is the method for dewatering the SCM for maintenance? structure structure structure structure structure structure structure
10 If applicable,will the SCM be cleaned out after construction? Yes Yes Yes Yes Yes Yes Yes
11 Does the maintenance access comply with General MDC(8)? Yes Yes Yes Yes Yes Yes Yes
12 Does the drainage easement comply with General MDC(9)? N/A N/A N/A N/A N/A N/A N/A
13 If the SCM is on a single family lot,does(will?)the plat comply with General
MDC(10)? N/A N/A N/A N/A N/A N/A N/A
14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes Yes Yes Yes Yes Yes
15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes Yes Yes Yes Yes Yes
16 Does the SCM follow the device specific MDC? N/A N/A N/A N/A N/A N/A N/A
17 Was the SCM designed by an NC licensed professional? Yes Yes Yes Yes Yes Yes Yes
- Submerged Gravel Wetland MDC
18 Bottom of the SGW cell(fmsl) 319 315.5 319 335 346 331.5 336
19 Ponding depth of the design storm(inches) 24" 41" 43.44" 33.24" 40.8" 49.32" 37"
20 Surface area of the SGW(square feet) 24553 28518 11605 43292 26234 10970 38834
21 Design volume of SCM(cu ft) 251752 256070 126503 368117 249473 114059 233636
22 Is the SGW used for peak attenuation? Yes Yes Yes Yes Yes Yes Yes
23 Depth of peak attenuation over planting surface(in)(100-yr event) 62" 68" 65.5" 56" 64.56" 74" 60"
24 Height of peak attenuation outlet above the planting surface(in) 39" 42" 45" 36" 42" 51" 39"
25 Diameter of the underdrain pipes(if applicable) 6" 6" 6" 6" 6" 6" 6"
26 Does the design include Internal Water Storage(IWS)? Yes Yes Yes Yes Yes Yes Yes
27 if so,elevation of the top of the IWS(fmsl) 322.5 319 322.5 338.5 349.5 335 339.5
28 Elevation of the planting surface(fmsl) 323 319.5 323 339 350 335.5 340
Native Native Native Native Native Native Native
29 Wetland Wetland Wetland Wetland Wetland Wetland Wetland
What type of vegetation will be planted? (grass,trees/shrubs,other)? Plants Plants Plants Plants Plants Plants Plants
30 Large Aggregate(Washed 57 Stone)Depth(inches) 36 36 36 36 36 36 36
31 Small Aggrgeate(Washed 78 Stone)Depth(inches) 6 6 6 6 6 6 6
32 Wetland Soil depth(inches) 6 6 6 6 6 6 6
33 Percentage of medium to coarse washed sand by volume 70 70 70 70 70 70 70
34 Percentage of fines(silt and clay)by volume <15 <15 <15 <15 <15 <15 <15
35 Percentage of organic matter by volume >15 >15 >15 >15 >15 >15 >15
36 Shredded Shredded Shredded Shredded Shredded Shredded Shredded
mulch or mulch or mulch or mulch or mulch or mulch or mulch or
Type of organic material compost compost compost compost compost compost compost
37 Phosphorus Index(P-Index)of media(unitless) <30 <30 <30 <30 <30 <30 <30
38 Will compaction be avoided during construction? Yes Yes Yes Yes Yes Yes Yes
39 Depth of mulch,if applicable(inches) N/A N/A N/A N/A N/A N/A N/A
40 Type of mulch,if applicable N/A N/A N/A N/A N/A N/A N/A
41 How many clean out pipes are being installed? 7 9 4 9 13 5 8
42 Type of pretreatment that will be used: Forebay Forebay Forebay Forebay Forebay Forebay Forebay