Loading...
HomeMy WebLinkAboutSW6080804_Utility Plan_20100608INV=494.50 C=__ 1/4 TURN FULL PORT BRONZE BALL SHUT-OFF VALVE #1 SEE NOTE #2 TEST COCK #1 CHECK VALVE #1 (SEE NOTE #3) 7-CHECK VALVE #2 , EXISTING CONCRETE LOCATION MAP NOT TO SCALE UTIUTY NOTES: 1. EXACT LOCATIONS OF WATER SERVICE CONNECTIONS ARE REQUIRED FOR AS BUILT RECORDS. 2. MINIMUM COVER OF 36" FOR WATER AND SEWER LINES. 3. D.I.P. REQUIRED FOR WATER AND SEWER LINES IF FOLLOWING CONDITIONS ARE NOT MET: -12" CLEARANCE FROM STORM DRAINS, GAS MAINS, TELEPHONE DUCT BANKS AND UNDERGROUND CABLES. -18" VERTICAL CLEARANCE FOR WATER LINE INSTALLED ABOVE SEWER LINE. -WATER LINE CROSSING UNDER SEWER LINE. -10' HORIZONTAL SEPARATION FOR WATER PARALLEL TO SEWER LINE. 4. SIZE AND LOCATION OF EXISTING WATER AND SEWER LINES TO BE VERIFIED BY THE CONTRACTOR. 5. CONTRACTOR SHALL COORDINATE THE PROPOSED WATER AND SEWER LINE WORK WITH THE CITY OF RAEFORD. 6. MATERIAL AND WORKMANSHIP REQUIREMENTS TO BE IN ACCORDANCE WITH THE CITY OF RAEFORD WATER AND SEWER POLICIES, PROCEDURES, STANDARDS AND SPECIFICATIONS FOR PUBLIC AND PRIVATE WATER AND SEWER LINES. 7. ALL 6" SANITARY SEWER LATERALS SHALL HAVE MIN. 2.0% SLOPE. B. CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE ISAACS GROUP A MINIMUM OF 48 HOURS IN ADVANCE PRIOR TO THE CONSTRUCTION OF WATER AND SEWER LINES TO ALLOW A REPRESENTATIVE FROM THE ISAACS GROUP TO PERIODICALLY BE ON -SITE DURING INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN AS -BUILT SURVEY OF THE WATER AND SEWER LINES TO THE ISAACS GROUP UPON COMPLETION OF INSTALLATION. 9. PROVIDE MINIMUM OF 48 HOUR NOTICE TO OWNER OR REPRESENTATIVE. 10. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY UTILITY DAMAGED DURING CONSTRUCTION. 11. THE CONTRACTOR SHALL USE EXTREME CARE WHEN WORKING NEAR ALL UNDERGROUND AND OVERHEAD UTILITIES. 12. PROP. EMPTY CONDUITS AND LATERALS TO BE CAPPED AND MARKED AT EACH END WITH 1/2" REBAR DRIVEN 3' INTO THE GROUND AND FLAGGED.(TYP.) 13. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER -USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS REQUIRED BACKFLOW PREVENTER. 14. EACH BACKFLOW PREVENTION ASSEMBLY IS REQUIRED TO BE TESTED BY A APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. PAV OR TO B SEWER LATERAL SLOPE TO TERMINAL DEPTH AT 1.5% MINIMUM. (TYP.) 1. NO OBJECT SHALL PROTRUDE FROM THE METAL CLEANOUT BOX COVER ABOVE THE ASPHALT OR CONCRETE SURFACE. SANITARY SEWER CLEANOUT DETAIL 1101-43 PqR/qeq p /v'E. /c RAW 1. THIS MAP IS NOT A CERTIFIED SURVEY. BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY KESTLER SURVEYING, INC. 2. THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THIS PLAN; THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. CONFLICTS BETWEEN EXISTING UTILITIES AND PROPOSED EXCAVATION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 3. PROVIDE MINIMUM OF 48 HOUR NOTICE TO OWNER OR REPRESENTATIVE PRIOR TO INTERRUPTION OF ANY EXISTING UTILITY, IF BEING UTILIZED. 4. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY UTILITIES DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR LOCATION & PROTECTION OF EXISTING ABOVE AND BELOW GROUND UTILITIES AND STRUCTURES. ANY AND ALL MAINS OR INDIVIDUAL SERVICES PRESENTLY IN SERVICE WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED IMMEDIATELY AT NO ADDITIONAL EXPENSE TO THE UTILITY OWNER. ANY AND ALL MAINS OR INDIVIDUAL SERVICES PRESENTLY NOT IN SERVICE AND WHICH ARE TO BE REPLACED DURING THE COURSE OF CONSTRUCTION MAY BE REMOVED AND LEGALLY DISPOSED OF IF DAMAGED DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL USE EXTREME CARE WHEN WORKING NEAR ALL UNDERGROUND AND OVERHEAD UTILITIES. 6. HANDICAP SIGNAGE TO BE INSTALLED IN ACCORDANCE WITH A.D.A STANDARDS AT H/C PARKING SPACES SHOWN. 7. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 8. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL NECESSARY PERMITS AND APPROVALS HAVE BEEN OBTAINED PRIOR TO CONSTRUCTION. THESE PERMITS AND APPROVALS MAY INCLUDE BUT ARE NOT LIMITED TO GRADING, DEMOLITION, ZONING, BUILDING, DRIVEWAY, DETENTION, SUBDIVISION, SPECIAL USE, SEWER AND WATER. I•_ p^s d p �� ir _ LAJ 03 SW a W m �3o j JAMES N. DRAKOS TAX #694240801023 DEED BK 206. PG 307 LONZELL KELLY TAX #694240801071 DEED SK 194, PG 097 EXISTING 3/4" WATER -METER TO BE USED OR IRRIGATION PROP. 2" REDUCED PRESSURE BACKFLOW PREVENTER INSTALLED ABOVE GROUND WITHIN AN INSULATED ENCLOSURE W/DRAIN PORTS. BACKFLOW PREVENTER INSTALLED ABOVE GROUND WITHIN AN INSULATED ENCLOSURE W/DRAIN PORTS. Mir. 4 -EMPTY CONDUIT w I3 N �O PROP. 4" SAN. SEWER DRAIN RIM=499.33 I.E.(OUT)=496.00 JOSEPHINE FLOWERS TAX #69424080106•' ao DEED BK 222, PG a PROP. 97 LF. OF 4" SAN. SEWER -1.5% (MIN) W/CLEANOUTS 75' O.C. PROP. 48.5 LF. OF 4" SAN. SEWER --l.5% (MIN) W/CLEANOUTS 75' O.C. REMOVABLE INSULATED ENCLOSURE WITH DRAIN PORTS. SLOPE GROUND AWAY FROM COVER (TYP.)- FLOW- STRAINER --% LOWEST OPTIONAL POINT g OR RELIEF VALVE OUTLET Pk I 4' MINIMUM-J V-SUPPORT AND PAD #67 WASHED AS REQUIRED BY STONE DESIGNER (PAD IS OPTIONAL) 1/4 TURN FULL PORT BRONZE BALL SHUT-OFF VALVE #2 SEE NOTE #2 TYPE K OR L COPPER TUBING OR 1" MIN. GALVANIZED STEEL PIPE FOR MIN. OF 5' ON EACH END OF ASSEMBLY. SEE NOTE #4 NOTES: 1. REDUCED PRESSURE PRINCIPLE ASSEMBLIES (RP) MUST BE APPROVED BY THE CITY OF RAEFORD PUBLIC WORKS DEPT. 2. APPROVED RP INCLUDES SHUT-OFF VALVES #1 AND #2 AS PART OF THE ASSEMBLY. 3. TEST COCK #1 SHALL BE UPSTREAM OF SHUT-OFF VALVE #1 AND IS PART OF THE APPROVED ASSEMBLY. 4. PIPE MATERIAL AND FITTINGS SHALL BE APPROVED BY THE CITY OF RAEFORD 5. INSULATED ENCLOSURE SHALL BE APPROVED BY THE CITY OF RAEFORD. 6. ALL LOCATIONS FOR BPA'S REQUIRE CITY OF RAEFORD APPROVAL 7. NO TAPS, BRANCHES, FH'S OR OTHER ACCESSORIES ARE PERMITTED ON THE PIPING BETWEEN THE BPA & METER. BACKFLOW PREVENTION STANDARD DETAIL GENERAL NOTES: 1 CONCRETE: 28 DAY COMPRESSIVE STRENGTH F'E = 4,500 PSI 2 REINFORCEMENT: ASTM A-615, GRADE 60 3 DESIGN: AC1318-83 BUILDING CODE ASTM C-857 MINIMUM STRUCTUAL DESIGN LOADING FOR UNDERGROUND PRECAST CONCRETE UTILITY STRUCTURE. 4 LOADS: H-20 TRUCK WHEEL WITH 30% IMPACT PER AASHTO 5 FILL W/ CLEAN WATER PRIOR TO "START-UP' OF SYSTEM 6 CONTRACTOR TO SUPPLY AND INSTALL ALL PIPING AND SANITARY TEES, CLEAN OUTS, FOR CLEANING TOWARD TRAP AND FOR CLEANING AWAY FROM TRAP ON BOTH THE INLET AND OUTLET/ALT. DUAL SWEEP CLEAN OUTS. 7 GRAY WATER ONLY, BLACK WATER SHALL BE CARRIED BY SEPARATE SEWER 8 EFFLUENT FILTER REQUIRED: ZABEL A300-12 OR EQUAL 1 REDUCED PRE SU E PRJNCIQLE ASSEMBLY RP 3//4 -2 ABOVE G OUND Q MARILYN E. SMITH TAX #694240801062 DEED BK 595, PG 285 CHARLES E. GREEN TAX #694240801061 DEED BK 47Z PG 822 GRAPHIC SCALE 1 INCH = 20 FEET VENT PIPE, OPTIONAL lHLEI A S BOTH SIDES 1ST TO LOCKING FRAME & COVER 'IF /AIR & GAS TIGHT 4 WAY INSPECTION I j TEE r� DUAL SWEEP TEE FOR v PRECAST BAFFLE �+ ' 4" THICK 1' 1 1' 10" 1500 GAL. GREASE TRAP LEGEND G EXISTING GAS LINE SS EXISTING SANITARY SEWER LINE W EXISTING WATER LINE - - - - - - - - - EXISTING STORM DRAINAGE PIPE a EXISTING CATCH BASIN EXISTING SAN. SEWER MH C0-3 EXISTING UTILITY POLE m EXISTING WATER VALVE Rol Lin PROPOSED CATCH BASIN ------SS PROPOSED SANITARY SEWER LINE W PROPOSED WATER LINE C PROPOSED EMPTY CONDUIT --------- PROPOSED STORM DRAINAGE PIPE C.O. E PROPOSED CLEAN OUT (75' O.C.)