Loading...
HomeMy WebLinkAboutSW8140415_HISTORICAL FILE_20140717STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 N DLi 15 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ® HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2 o I y O "1 1 "1 YYYYMMDD AGA` NC®ENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor July 17, 2014 Andrew O. Bergeron, Member Manager BCC of Edenton, LLC 1415 N. Broad Street Edenton, NC 27932 Subject: State Stormwater Management Permit No. SW8140415 Colony Tire High Density Commercial Infiltration Basin Project New Hanover County Dear Mr. Bergeron: John E. Skvarla, III Secretary The Wilmington Regional Office received a complete Stormwater Management Permit Application for Colony Tire's expansion project on July 16, 2014. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000 and Session Law 2008- 211. We are forwarding Permit No. SW8 140415 dated July 17, 2014, for the construction, operation and maintenance of the BMP's and built -upon areas associated with the subject project. This permit shall be effective from the date of issuance until July 17, 2022, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, procedures for changing ownership, transferring the permit, and renewing the permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to transfer the permit, or to renew the permit, will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center, Raleigh, NC 27699- 6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Steve Pusey in the Wilmington Regional Office, at (910) 796-7215. Smc rely, For racy D s, P.E., D rector Division of Energy, M neral and Land Resources GDS/ sgp: G:\WQ\Shared\Stormwater\Permits & Projects\2014\140415 HD\2014 07 permit 140415 cc: Monica Valsi — Tripp Engineering New Hanover County Building Inspections Beth E. Wetherill, New Hanover County Engineering Wilmington Regional Office Stormwater File Division of Energy, Mineral, and Land Resources Land Quality Section —Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 • (910) 796-7215 / Fax: (910) 350-2004 State Stormwater Management Systems Permit No. SW8 140415 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO BCC of Edenton, LLC Colony Tire 3625 US 421 North, Wilmington, New Hanover County FOR THE construction, operation and maintenance of one (1) infiltration basin in compliance with the provisions of Session Law 2008-211 and 15A NCAC 2H .1000 (hereafter the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division and considered a part of this permit. This permit shall be effective from the date of issuance until July 17, 2022, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.7 of this permit. The stormwater control has been designed to handle the runoff from 47,230 square feet of impervious area. 3. Per section .1008 (h) of the stormwater rules, this alternative design infiltration basin provides equal or better protection because it infiltrates a 10-year, 24-hour storm without discharging, using an infiltration rate of one-half of the expected infiltration rate provided in the soils report. The infiltration basin is designed in accordance with Option 4 of Section 16.3.9 of the BMP manual; therefore, no bypass, no vegetated filter strip, and no additional storage volume are required. 4. The tract will be limited to the amount of built -upon area indicated in Section 1.7 of this permit, and as shown on the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 140415 No surface waters have been identified within or near the property. If surface waters are subsequently identified on or near the area permitted under Session Law 2008-211, it will be necessary to provide a 50' wide vegetative buffer measured horizontally from and perpendicular to the normal pool of impounded structures, the top of bank of each side of streams and rivers and the mean high water line of tidal waters. The following design criteria have been permitted for the infiltration basin and must be provided and maintained at design condition: a. Drainage Area, Acres: 1.4 acres Onsite, ft : 60,834 Offsite, ft2: 0 b. Total Impervious Surfaces, ft2: 47,230 Buildings, t2: 10,000 Parking, ft : 15,580 Existing, ft2: 21,650 C. Design Storm, inches: 1.5" d. Basin Depth, feet: 8.15 e. Bottom Elevation, FMSI : 7 f. Bottom Surface Area, ft : 329 g. Storage Elevation, fmsl: 13.75 h. Storage Surface Area, ft2: 6,456 i. Permitted Storage Volume, ft3: 18,927 j. Predevelopment 1 yr 24 hr peak flow, cfs: 0.62 k. Post -development 1 yr 24 hr peak flow, cfs: 0.0 I. Type of Soil: A M. Expected Infiltration Rate, in/hr: 3.0 n. Seasonal High Water Table, FMSL: 5 o. Time to Draw Down, days: 2.9 P. Receiving Stream/River Basin: Cape Fear q. Stream Index Number: 18-(63) r. Classification of Water Body: "C; Sw" II. SCHEDULE OF COMPLIANCE River / Cape Fear The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. If the stormwater system is used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. The permittee shall follow the approved Operation and Maintenance Agreement in its entirety, and shall provide and perform the listed operation and maintenance procedures at the specified intervals to assure the permitted stormwater system functions at optimum efficiency. 4. Records of maintenance activities. must be kept for each permitted BMP. The reports will indicate the date, activity, name of person performing the work and what actions were taken. The facilities shall be constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 140415 6. All stormwater collection and treatment systems must be located in public rights - of -way, common areas or easements. The final plats for the project will be recorded showing all such required rights -of -way, common areas and easements, in accordance with the approved plans. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans; including the stormwater management measures, built -upon area, details, etc. b. Redesign or addition to the approved amount of built -upon area or to the drainage area. C. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area. d. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. e. The construction of any designated future BUA on the application. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director. The permittee shall submit a completed and signed Name/Ownership Change Form, accompanied by the supporting documentation as listed on the form, to the Division at least 60 days prior to any one or more of the following events: a. An ownership change including the sale or conveyance of the project area in whole or in part; b. The sale or conveyance of the common areas to a Homeowner's or Property Owner's Association, subject to the requirements of Session Law 2011-256; c. Bankruptcy; d. Foreclosure; e. Dissolution of the partnership or corporate entity; f. A name change of the current permittee; g. A name change of the project; h. A mailing address change of the permittee; 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 140415 3. Approved plans, calculations, supplement forms, operation and maintenance agreements and specifications for this project are incorporated by reference and are enforceable parts of the permit. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. 4. Any individual or entity found to be in noncompliance with the terms and conditions of this permit or with the stormwater rules, is subject to enforcement action by the Division, in accordance with NCGS 143, Article 21. 5. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 6. In the event that the facilities fail to perform satisfactorily the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 7. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 8. The permit issued shall continue in force and effect until revoked or terminated. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 9. Unless specified elsewhere, permanent seeding requirements for the stormwater controls must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 10. The issuance of this permit does not prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules and regulations contained in Session Law 2008- 211, Title 15A NCAC 2H.1000, and NCGS 143-215.1 et. al. 11. The permittee shall submit a permit renewal application at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 17th day of July, 2014. TH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION �n Y racy mavis, r.t.,- nrecor Division of Energy, Mineral and Land Resources By Authority of the Environmental Management Commission Page 5 of 7 ,.DEMLR-USEONLY- Date Received Fee Paid Permit Number - -/ SO���D Sv Applicable Rules: ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph lI - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ M mt Plan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form inay be photocopied for use as an original 1. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): 2. Location of Project (street address): City:Wilmington County:New Hanover Zip:28401 3. Directions to project (from nearest major intersection): From the intersection of the I-140 exit ramp and US 421 N. Travel north approximately 0 25 mile 4. Latitude:34° 17' 35" N Longitude:77° 58' 18" W of the main entrance to the project. 1I. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tReneuals with modifications also requires SWU-102 - Renetual Application Form b.If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) and the status of construction: ❑Not Started ❑Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major ®Sedimentation/Erosion Control: _ ❑NPDES Industrial Stormwater ❑404/401 Permit: Proposed Impacts ac of Disturbed Area b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: 5. Is the project located within 5 miles of a public airport? ®No ❑Yes If yes, see S.L. 2012-200, Part VI: http://portaLncdenr.org/web/Ir/rules-and-regulations RECEIVE APR 17 20% Form SWU-101 Version Oct. 31, 2013 Page I of 6 BY: III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/ Organization: B CC of Edenton. LLC Signing Official & Title:Andrew O. Bergeron, Member Manager b.Contact information for person listed in item la above: Street Address:1415 N. Broad Street City:Edenton State:NC Zip:27932 Mailing Address (if applicable): State: Zip: Phone: (252 ) 482-5521 Fax: (252 ) 482-7626 t c. Please check the appropriate box. The applicant listed above is: ® The property owner (Skip to Contact hrformation, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/1 Signing Official & b.Contact information for person listed in item 2a above: Street Address: Mailing Address (if Phone: State: Fax: ( ) 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization:Colony Tire Signing Official & Title:Tom Taylor, Manager b.Contact information for person listed in item 3a above: Mailing Address:3625 US Hwy 421 N. City:Wilmington State:NC Zip:28401 Phone: (910 ) 343-8100 Email:ttaylor@colonytire.com 4. Local jurisdiction for building permits: Point of Fax: (910 ) 254-4714 Phone #: APR 17 2014 Form SWU-101 Version Oct. 31, 2013 Page 2 of 6 IV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Cape Fear River basin. 4. Total Property Area: 3.1 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+:3.1 acres Total project area shall be calculated to exclude the followin the normal pool of impounded structures, the area between the banks of streams and rivers, the area behalf the Normal High Water (NHW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MITM line. The resultant project area is used to calculate overall percent built upon area (BUA). Non -coastal wetlands larndvrard of tlne NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 9. How many drainage areas does the project have?1 (For high density, court 1 for each proposed engineered stornmrater BMP. For lord density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Draina a Area 1' Drainage Area Drainage Area _ Drainage Area _ Receiving Stream Name Cape Fear River Stream Class * C;Sw Stream Index Number * 18-(63) Total Drainage Area (so 60,834 On -site Drainage Area (sf) 60,834 Off -site Drainage Area (sf) - Proposed Impervious Area** (so 47,230 % Impervious Area** total 77.64% Impervious' Surface Area Drainage Area 1 Drainage Area Draina a Area Drainage Area _ On -site Buildings/Lots (so 10,000 On -site Streets (sf) - On -site Parking (so 15,580 On -site Sidewalks (so Other on -site (so Future (sf) Off -site (so - Existing BUA*** (sf) 21,650 Total (so: 47,230 Stream Class and Index Number call be determined at: httn://trortal.ncdenr.org rich/roq(ps/csn/classi cntimrs ** Inn ppervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sideroalks, gravel areas, etc. Form SWU-101 Version Oct. 31, 2013 Page 3 of 11. How was the off -site impervious area listed above determined? Provide documentation. Projects in Union County: Contact DEMLR Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per 15A NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://poital.ncdenr.org/web/wq/ws/su/bmp-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://Liortal.ncdenr.org/web/wq/ws/su/statesw/forms docs. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map atlittp://portal.ticdeiir.org/web/­wq/ws/su/iiiaps.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from http://portal,ncdenr.org/web/wq/ws/su/statesw/forms_docs. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. 0 U 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants (UA Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M a cy agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to http:/ /www.envhelp.org/pages/onestopexpress.html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor l( QJ the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the AY receiving stream drains to class SA waters within'/z mile of the site boundary, include the/2 mile radius on the map. 7. Sealed, signed and dated calculations (one copy). ttv- 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: mI V a. Development/Project name. b. Engineer and firm. c. Locationlnap with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. Os E I E .. • Delineate the vegetated buffer landward from the normal pool elevation of imp unded`1' structures, the banks of streams or rivers, and the MHW (or NHW) of tidal wat V APR 1 7 201fF i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. gy; 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). Form SWU-101 Version Oct. 31, 2013 Page 4 of 6 p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify mid _ elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xll" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DEMLR to verify the SHWPprior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: 5708 Page No: 1365 �4�'J _ 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC L Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 21-1.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. http://www.secretary.state.iic.us/Corporatioiis/CSearch.asl2x VIL DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from http://portaLncdenr.org/web/Ir/state-stormwater- forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Phillip G. Tripp, P.E. Consulting Firm: Tripp Engineering, P.C. Mailing Address:419 Chestnut Street City:Wilmington State:NC Zip:28401 Phone: (910 ) 763-5100 Email: tripl?eng@ec.rr.com Fax: (910 ) 763-5631 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled ont, complete this section) I, (print or type name of person listed in Contact Infonuation, itent 2a) certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, itenn la) with (print or type natne of organization listed in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. ECEIVE APR 17 2014 Form SWU-101 Version Oct. 31, 2013 Page 5 of 6 BY: As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. I, , a Notary Public for the State of I County of do hereby certify that personally appeared before me this _ day of , and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission X. APPLICANT'S CERTIFICATION I, (print or hjpe name of person listed in Contact Information, item la) Andrero O. BerQeron certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable storm ater rules under 15A NCAC 21-I .1000 and any other applicable state stormwater requirements. Signature:/In/ ////i Date: 2 I, , kU —a Notary Public for the State of h�C(l(Jjy.f-.—, Countyof Viler . do hereby certify that Ander ar 'T-,erOFro,' personally appeared before me this Z'6 day of Marry Zo lU , and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, c' �p'MgJ. .'OUBOC' SEAL My commission expires ECEWEA APR 11 1014 BY: Form SWU-101 Version Oct. 31, 2013 Page 6 of 6 TE 13026 State Stormwater Management Systems / Permit No. SW8 140415 Colony Tire Stormwater Project No. SW8 140415 New Hanover County Engineer's Certification I, Phillip G. tripp , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (period ically/weekiy/fu11 time) the construction of the project, (Project) for BCC of Edenton, LLC (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specifications: Signature I ) b Registration Number 17374 Date (O ' 0 ' kZ5 VE JUN 2 2 2015 SEAL s`,%I III I I r I /Oj CARp�'�. O;•�FEssj�•.;;�'� SEAL - o 17374 2 Z A HIA NIA W14 State Stormwater Management Systems Permit No. SW8 140415 Certification Requirements: Page 2 of 2 J1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. COL-3. All the built -upon area associated with the project is graded such that the runoff drains to the system. _4. All roof drains are located such that the runoff is directed into the system. �5. The bypass weir elevation is per the approved plan. �6. The bypass structure is located per the approved plans. 0-7. A Trash rack is provided on the outlet/bypass structure. -9-8. All slopes are grassed with permanent vegetation. (:Va� &ko"74 u►d06v.M4.( � 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. _&_12. All required design depths are provided. 40---13. All required parts of the system are provided. �14. The required system dimensions are provided per the approved plan. Pusey, Steven From: Monica Valsi <monica-trippeng@ec.rr.com> Sent: Tuesday, July 15, 2014 4:54 PM To: Pusey, Steven Subject: RE: Colony Tire Expansion Attachments: ColonyTire page 3 of SW Permit App.pdf; Colony Tire page 1 of Infiltration Basin Supplement.pdf; Colony Tire page 2 of calc.pdf Steve, As discussed earlier, attached please find a revised page 3 of the Stormwater Permit Application, a revised page 1 of the Infiltration Basin Supplement, and a revised page 2 of the calculations. Please note I did not change the percent impervious for the overall project area on page 3 of the Stormwater Permit Application, because there is existing impervious area outside of the drainage area, which we are not required to treat since the impervious area was pre 1988. The total proposed/existing impervious area is 86,970 sf as indicated in the Site Data Table on Sheet C1. Therefore, the percent impervious for the overall project area is 64.4. Please contact me with any questions or if you need additional information. Thank you, Monica From: Pusey, Steven [mailto:steven.pusey@ncdenr.gov] Sent: Tuesday, July 15, 2014 3:10 PM To: Monica Valsi Subject: RE: Colony Tire Expansion Ok. I get 2.9 days when I calculate that. You must use %z the infiltration rate of 3 in/hr. So that's 1.5 in/hr., right? So the equation is T = V / 2KA = 5,705 / 2*1.5*329 = 5.78 * (12in/ft) = 69.4 hours = 2.9 days Also, I just noticed on page 3 of the application, you need to input 60,834 sf as the drainage area so it matches your calculations. Also, the percent impervious should be 77.6% for the drainage area, and 35% for the overall project area (see item 8). Please revise and resubmit this page. Thanks, Steve From: Monica Valsi [mailto:monica-trippeng@ec.rr.com] Sent: Tuesday, July 15, 2014 2:36 PM To: Pusey, Steven Subject: RE: Colony Tire Expansion 329, the square footage of elevation 7.0 From: Pusey, Steven[maiIto: steven.pusev@ncdenr.gov] Sent: Tuesday, July 15, 2014 2:29 PM To: Monica Valsi Subject: RE: Colony Tire Expansion What did you use for area? J From: Monica Valsi (mailto:monica-triooeng(ilec.rr.com] Sent: Tuesday, July 15, 2014 2:28 PM To: Pusey, Steven Subject: RE: Colony Tire Expansion Steve, I used the equation on the bottom of 16-7 of the BMP manual. The drawdown time should be 1.65 days not 1.41. From: Pusey, Steven [maiIto: steven.pusey(&ncdenr.gov] Sent: Tuesday, July 15, 2014 12:24 PM To: Monica Valsi Subject: RE: Colony Tire Expansion Monica, I was just checking the calculations on subject project. How did you calculate the drawdown time of 1.41 days? Steve From: Monica Valsi [mailto:monica-trippeng0ec.rr.com] Sent: Monday, July 14, 2014 10:50 AM To: Pusey, Steven Subject: RE: Colony Tire Expansion Hey Steve, Just checking in with you on where we are in the rotation so I can advise our client. Any information will be greatly appreciated. Many thanks, Monica From: Pusey, Steven [mailto:steven.ouseyC(bncdenr.00v] Sent: Tuesday, July 1, 2014 10:08 AM To: Monica Valsi Subject: RE: Colony Tire Expansion Monica, Yes, I received them. However, I won't be able to get to them right away. The application will go back into the rotation so it could be a couple weeks before I get back with you on it. Lead times on permits are getting longer because our department got cut back so much. Steve From: Monica Valsi [mailto:monica-trippenq(@ec.rr.com] Sent: Tuesday, July 01, 2014 9:40 AM To: Pusey, Steven Subject: RE: Colony Tire Expansion Good morning Steve, I'm just checking to confirm you received revised plans addressing your comments/concerns on the subject project. Revised submittal was hand delivered on Wednesday, June 25"'. Thanks, Monica From: Pusey, Steven [mailto:steven.pusey(dncdenr.gov] Sent: Tuesday, June 24, 2014 3:37 PM To: Monica Valsi Subject: RE: Colony Tire Expansion Ok. Thanks, Steve From: Monica Valsi [mailto:monica-trippeng(&ec.rr.com) Sent: Tuesday, June 24, 2014 1:40 PM To: Pusey, Steven Subject: RE: Colony Tire Expansion Steve, I've completed addressing all agencies comments. We will re -submit revised plans as well as any calcs or supplements to you today or tomorrow. A letter addressing your comments will be provided. Thank you, Monica From: Pusey, Steven [mailto:steven.ousev(�)ncdenr.gov] Sent: Tuesday, June 17, 2014 10:41 AM To: Monica Valsi Subject: RE: Colony Tire Expansion Okay. Great! Steve From: Monica Valsi [mailto:monica-trippeno(�)ec.rr.com] Sent: Tuesday, June 17, 2014 10:03 AM To: Pusey, Steven Subject: RE: Colony Tire Expansion Hey Steve, I'm working on it ... I have comments from all agencies that I'm addressing as well. Got pulled off this for today but will be back on it tomorrow. Hope to have all comments addressed by the end of the week. From: Pusey, Steven [mailto:steven.ousevCo)ncdenr.gov] Sent: Tuesday, June 17, 2014 9:32 AM To: Monica Valsi (monica-trippeno(bec.mcom) Subject: FW: Colony Tire Expansion Any information on this yet? Steve From: Pusey, Steven Sent: Thursday, June 12, 2014 9:58 AM To: 'Monica Valsi' Subject: RE: Colony Tire Expansion Monica, Thanks for the map which was very helpful. In addition, can you send me documentation showing that the existing buildings, gravel parking, etc. were built before 1988? An old survey or plat would help to illustrate the existing BUA that is now being captured by the new infiltration basin, thus justifying the variance for the additional pavement at the front of the lot. Thanks, Steve From: Monica Valsi [maiIto: monica-trippengCalec.rr.com] Sent: Thursday, June 12, 2014 9:13 AM To: Pusey, Steven Subject: Colony Tire Expansion Steven, As discussed earlier attached is a PDF of the drainage area going to the infiltration basin. Please contact me with any additional questions or comments. Thank you, Monica Valsi, E.I. Tripp Engineering, P.C. 419 Chestnut Street Wilmington, NC 28401 (p)910.763.5100 (f) 910.763.5631 monica-trippeng@ec.rr.com NOTICE: This electronic correspondence and all attachments may contain privileged information intended only for the use of the addressee. Any information contained within this correspondence is provided for your convenience. No assertion of accuracy is made by Tripp Engineering, P.C. unless physical documents are obtained, sealed AND signed. User assumes all responsibility for use of this digital information. This email is free from viruses and malware because avast! Antivirus protection is active. TRIPP ENGINEERING, P.C. 0 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 • FAX: (910) 763-5631 June 24, 2014 NCDENR Division of Energy, Mineral and Land Resources 127 Cardinal Drive Extension Wilmington, NC 28405 Attn: Mr. Steven G. Pusey Re: Colony Tire TE 13026 Dear Steven: In response to your email comments dated June 11 and June 12, 2014, we offer the following: f1. Your design rainfall depth is 1.66 inches. It should be 1.5 inches according to the Rules. This will change some other calculations and the numbers entered into the Supplement form, like Minimum Design Volume Required • The design rainfall depth has been revised to 1.5 inches. Revised calculations and supplement form are provided. 2. Bottom surface area in your Supplement form is stated as 2,758 sf. How is this calculated? • The bottom surface elevation has been revised to elevation 7 in lieu of 11. The surface area is irregular shaped and is calculated by selecting the object in AutoCAD and listing the area. 3. Provide documentation showing that the existing buildings, gravel parking, etc. were built before 1988. • Attached is a 1981 aerial of the site taken from NHC GIS. Please review for approval and contact us with any questions, comments or if you need additional information. Thank you. Sincerely, Tripp Engineering, P.C. Mtn Ca/U44 Monica Valsi, E.I. MLV:dcb Enc. JUN, 2 5 20% 11 BY:e--�.� , if,- I 4 t •'f{�f F M PAM` t'Tbt fia aft ����t i'�=`' �' �.z4 'fie• ;4`hrr S r. rF'+;, . _ � i° { ,1)'atr . c vY f� 7�ii�,Rt ''�1['+: i?T.i•� 06/24/2014 Colony Tire 13026 MVL Simple Method - 1.5" Storage Volume Calculations Storage Volume - Non SA Waters - Minimum Volume Required Volume of Runoff = V = (3630) (Design Rainfall Depth) (Rv) (Drainage Area) where Rv= 0.05+0.009&) Rv = Runoff Coefficient = storm runoff (inches) / storm rainfall (inches) Iq = Impervious Fraction = Impervious portion of the drainage area (acres) / Drainage area (acres) lq= 77.6 Rv= 0.75 Design Rainfall Depth = 1.50 in. Drainage Area = 1.40 acres Volume Required = 5,705 ft' Volume Provided = 20.376 fit' `..%'�N CARO//i�� =0�•.FESSj0%. 5%, aT 2� 9! t9 SEAL (,•Z+.A- ECEIVE JUN 2 5 2014 BY: GNOBS\2013\13036Lohany rare\-Ic$V4COENR 5W Only\13026 Storage Nato me Caks Is inch 06/24/2014 Colony Tire 13026 MLV CN and C Values PRE DEVELOPMENT Determine Composite CN Value from TR-55 Table 2-2 'Soil Type: Sand Description HSG CN A (ac) CN x A Impervious (on -site) - 98 0.13 12.74 Wooded A 45 0.34 15.30 0.4 228.04 Composite CN Value = 60 Pre Development Composite Runoff Coefficient Description C A (ac) C x A Impervious 0.95 0.13 0.1235 Wooded 0.10 0.34 0.034 0A7 0.1575 Composite CValue = 0.34 POST DEVELOPMENT Determine Composite CN Value from TR-55 Table 2-2 *Soil Type: Sand Description HSG CN A (ac) CN x A Impervious - 98 1.08 105.84 Open Space (Fair) A 39 0.32 12.48 1.40 118.32 Composite CN Value = 85 Post Development Composite Runoff Coefficient Description C A (ac) C x A Impervious 0.95 1.08 1.026 Lawns, sandy soil, flat 0.10 0.32 0.032 1.40 1.058 Composite CValue = 0.76 Total Drainage Area s . ft. acres 60,834 1.40 Post Development Im ervious Area Land Use sq. acres Proposed Impervious 1.08 Total 1.08 impervious = 0.776 = 77.6% G:UOBS\2013\13026-Colony Tire\calCs\NCDENR SW Only\CN 8 C Value Calcs 6/24/2014 Colony Tire 3026 MLV Stormwater Infiltration Basin Routing 1-year 24hr Stomn WATERSHED DATA BEFORE DEVELOPMENT WATERSHED AREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY / YR 3.90 IN/HR Oa = 0.62 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P= 3.76 INCHES 1yr, 24hr PRECIPITATION CN= 85 S = (1000/CN)-10 S = 1.76 Depth (D) _ (P-0.2S)A21(P+0AS) D = 2.24 IN - 1yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tip, = [(43.5)(D)(Area)] / Op Tip = 11.06 MINUTES Storage Volume Req'd = (Dp-0a)'Tp'1.39'60 3,252 cu. ft. CALCULATE Ks AND to SET NORMAL ELEVATION AT= 7.00 feet AFTER DEVELOPMENT WATERSHEDAREA 1.40 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFFCOEF.'C' 0.76 TIME OF CONCENTR 5.00 MIN INTENSITY 1 YR 3.90 IN/HR Op= 4.15 CFS Dip = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) (ft) (ft) 7.00 329 0 0 0 0 0 0 8.00 676 503 503 1.0 6.2196 0 1.09 9.00 1155 916 1,418 2.0 7.2570 0.6931 1.89 10.00 1818 1487 2.905 3.0 7.9740 1.0986 2.77 11.00 2792 2.305 5.210 4.0 8.5582 1.3863 3.78 12.00 3969 3.381 8,590 5.0 9.0584 1,6094 4.93 13.00 5363 4.666 13.256 6.0 94922 1,7918 6.21 14.00 6984 6,174 19,430 7.0 9.8745 1.9459 7.61 15.15 9047 8.016 27.445 8.2 10.2199 2.0980 9.15 Regression Output: Ks = 427 b= 1.88 X Coefficient 6.06 SyN 2 � 201b G'.UOaS2013U3026-Colony Tirekala NCDENR SW Only%130261nftlo-ation Rowing 1yr24h, 7/1512014 Colony Tire 13026 MLV Slormwater Infiltration Basin Routing 1-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 0.62 cis Op = 4.15 cis ' Infiltration rate = Dhul Tip = 11.1 min (Per Soils Report) dT = 4 min BASIN DATA Basin Drawdown Time = 2.9 days Ks = 427 b= 1.88 Zo = 7.00 It Normal water elev, = 7.00 ft Peak Outflow= 0.00 cfs Box Weir Length = 5 It Peak Stage = 10.17 ft C. = 3.0 Maximum Storage = 3,750 cu It Zcr = 14.00 it Control Holes: State Orifice: Din = 0.00 in Do= Din Inv = 0.00 ft Cd = 0 Weir: L = 0 in Zi = 0.00 ft Inv = 0.0 it Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFSlore Infiltrate (min) (CIS) (cu ft) (ft) (CIS) (CIS) (CIS) lots) (cis) (cu ft) (of) 0 0.0 0 TOO 0 0 0 0 0.00 0.0 0.0 4 1.2 0 7.00 0 0.00 0 0 0,00 0.0 5.5 8 3A 288 7.79 0.00 0.00 0.0 0.00 0.00 277.4 11.0 12 4.1 1108 8.65 0.00 0,00 0.0 0.00 0.00 1091.4 16.5 16 2.7 2086 9,31 0.00 0.00 0.0 0.00 0.00 2064A 21.9 20 1.7 2745 9.67 0.00 0.00 0.0 0.00 0.00 2717.5 27A 24 1.1 3157 9.88 0,00 0.00 0.0 0.00 0,00 3123.8 32S 28 0.7 3414 10.00 0,00 000 0.0 0.00 0.00 3375.6 38A 32 04 3575 10.07 0.00 0.00 0.0 0,00 0,00 3530.9 43.9 36 0.3 3675 10.12 0,00 000 0.0 0,00 0.00 3625.9 49.4 40 0.2 3738 10.14 0.00 0.00 0.0 0.00 0.00 3683.2 54.B 44 0.1 3777 10.16 0.00 0.00 0.0 0.00 0.00 3716.9 60.3 48 0.1 3802 10.17 0.00 0.00 0.0 0.00 0.00 3735.9 65.8 52 0.0 3817 10.17 0.00 - 0.00 0.0 0.00 0,00 3745.8 71.3 56 0.0 3827 10.17 0.00 0.00 0.0 0.00 0,00 3749.9 76A 60 0.0 3833 10.17 0.00 0.00 0.0 0.00 0.00 3750A 82.3 64 0.0 3836 10,17 0.00 0.00 00 0,00 0.00 3748.6 87.7 68 0.0 3839 10.17 0,00 0.00 0.0 0.00 0.00 3745.5 93.2 72 0.0 3840 10.17 0,00 0.00 0.0 0.00 0.00 3741.4 98.7 76 D.0 3841 10.17 0.00 0,00 00 0.00 0.00 3736.9 104.2 80 0.0 3842 10.17 0.00 0.00 0.0 0.00 0.00 3732.0 109.7 84 0.0 3842 10.16 0.00 0.00 0.0 0,00 0.00 3726.8 115.2 68 0.0 3842 10.16 0.00 0,00 0.0 0.00 0.00 3721.E 120.6 92 0.0 3842 10.16 0.00 0,00 0.0 0.00 0,00 3716.2 126.1 96 0.0 3842 10.16 11.00 0,00 0.0 0.00 0,00 37108 131.6 100 0.0 3842 10,15 0,00 0,00 0.0 0.00 0.00 3705A 137.1 104 0.0 3843 10.15 0,00 0.00 0.0 0.00 0.00 3699.9 142.6 108 0.0 3843 10.15 000 0.00 0.0 0.00 0,00 3694.5 148.1 112 0.0 3843 10.15 0.00 0,00 0.D 0.00 0.00 3689.0 153.5 116 0.0 3843 10.14 0.00 0.00 0.0 0.00 0,00 3683.5 159.0 120 0.0 3843 10.14 0.00 0,00 0.0 0.00 0,00 3678.1 164.5 124 0.0 3843 10.14 0,00 0,00 0.0 0.00 0.00 3672.E 170.0 128 0.0 3843 10.14 0.00 0.00 0.0 0.00 0,00 3667.1 175.5 132 0.0 3843 10.13 0.00 0.00 0.0 0.00 0,00 3661.6 181.0 136 0.0 3843 10.13 0,00 0.00 00 000 - 0,00 3656.1 186A 140 0.0 3843 10.13 0.00 0.00 0.0 0.00 0.00 3650.7 191.9 144 0.0 3843 10.13 0.00 0.00 0.0 0.00 0,00 3645.2 197.4 148 0.0 3843 10.12 0.00 0.00 0.0 0.00 0.00 3639.7 2029. 152 0.0 3843 10.12 0,00 0.00 0.0 0.00 0.00 3634.2 208.4 156 0.0 3843 10,12 0.00 0.00 0.0 0.00 0,00 3628.7 213S 160 0.0 3843 10,12 0,00 0.00 0.0 0.00 0.00 3623.2 219.3 164 0.0 3843 10.11 0,00 0.00 0.0 0.00 000 3617.8 224,8 168 0.0 3843 10.11 0,00 0.00 0.0 0.00 0.00 3612.3 230.3 172 0.0 3843 10.11 0,00 0.00 D.0 0.00 0.00 3606.8 235S 176 0.0 3843 10,11 O.OD 0.00 0.0 0.00 0,00 3601.3 241.3 180 0.0 3843 10,10 0.00 0.00 0.0 0.00 0.00 3595.E 246.8 184 0.0 3843 10.10 0,00 0.00 0.0 0.00 0.00 3590.3 252.2 188 0.0 3843 10.10 0.00 0.00 0.0 0.00 0,00 3594.9 257.7 G UOSSiWIMI3026Colony Tlmicalc %COENR SW Onlyn302a Infiltration Routing lyQ4hcxla 6/2412014 Colony Tire MLV Stormwater Infiltration Basin Routing 13026 1-year 24hr Storm 192 0.0 3843 10.10 0.00 0.00 0.0 0.00 0.00 3579.4 263.2 196 0.0 3843 10.09 0.00 0.00 0.0 0.00 0.00 3573.9 268.7 200 0.0 3843 10.09 0.00 0.00 0.0 0.00 0.00 3568.4 274.2 204 0.0 3843 10.09 0.00 0.00 0.0 0.00 0.00 3562.9 279.7 208 0.0 3843 10.09 0.00 0.00 0.0 0.00 0.00 3557.4 285.1 212 0.0 3843 10.08 0.00 0.00 0.0 0.00 0.00 3552.0 290.6 216 0.0 3843 10.08 0.00 0.00 0.0 0.00 0.00 3546.5 296.1 220 0.0 3843 10.08 0.00 0.00 0.0 0.00 0.00 3541.0 301.E 224 0.0 3843 10.08 MO 0.00 0.0 0.00 0.00 3535.5 307.1 228 0.0 3843 10.07 0.00 0.00 0.0 0.00 0.00 3530.0 312.6 232 0.0 3843 10.07 0.00 0.00 0.0 0.00 0.00 3524.5 318.0 236 0.0 3843 10.07 0.00 0.00 0.0 0.00 0.00 3519.1 323.5 240 0.0 3843 10.07 0.00 0.00 0.0 0.00 0.00 3513.6 329.0 244 0.0 3843 10.06 0.00 0.00 0.0 0.00 0.00 3508.1 334.5 248 0.0 3843 10.06 0.00 0.00 0.0 0.00 0.00 3502.6 340.0 252 0.0 3843 10.06 0.00 0.00 0.0 0.00 0.00 3497.1 345.5 256 0.0 3843 10.06 0.00 0.00 0.0 0.00 0.00 3491.6 350.9 260 0.0 3843 10.05 0.00 0.00 0.0 0.00 0.00 3486.2 356.4 264 0.0 3843 10.05 0.00 0.00 0.0 0.00 0.00 3480.7 361.9 268 0.0 3843 10.05 0.00 0.00 0.0 0.00 0.00 3475.2 367.4 272 0.0 3843 10.05 0.00 0.00 0.0 0.00 0.00 3469.7 372.9 276 0.0 3843 10.04 0.00 0.00 0.0 0.00 0.00 3464.2 378.4 280 0.0 3843 10.04 0.00 0.00 0.0 0.00 0.00 3458.7 383.8 284 0.0 3843 10.04 0.00 0.00 0.0 0.00 0.00 3453.3 389.3 288 0.0 3843 10.04 0.00 0.00 0.0 0.00 0.00 3447.8 394.8 292 0.0 3843 10.03 0.00 0.00 0.0 0.00 0.00 3442.3 400.3 296 0.0 3843 10.03 0.00 0.00 0.0 0.00 0.00 3436.8 405.8 300 0.0 3843 10.03 0.00 0.00 0.0 0.00 0.00 3431.3 411.3 304 0.0 3843 10.03 0.00 0.00 0.0 0.00 0.00 3425.8 416.7 308 0.0 3843 10.02 0.00 0.00 0.0 0.00 0.00 3420.4 422.2 312 0.0 3843 10.02 0.00 0.00 0.0 0.00 0.00 3414.9 427.7 316 0.0 3843 10.02 0.00 0.00 0.0 0.00 0.00 3409.4 433.2 320 0.0 3843 10.01 0.00 0.00 0.0 0.00 0.00 3403.9 438.7 324 0.0 3843 10.01 0.00 0.00 0.0 0.00 0.00 3398.4 444.2 328 0.0 3843 10.01 0.00 0.00 0.0 0.00 0.00 3392.9 449.6 332 0.0 3843 10.01 0.00 0.00 0.0 0.00 0.00 3387.5 455.1 336 0.0 3843 10.00 0.00 0.00 0.0 0.00 0.00 3382.0 460.6 340 0.0 3843 10.00 0.00 0.00 0.0 0.00 0.00 3376.5 466.1 344 0.0 3843 10.00 0.00 0.00 0.0 0.00 0.00 3371.0 471.6 348 0.0 3843 10.00 0.00 0.00 0.0 0.00 0.00 3365.5 477.1 352 0.0 3843 9.99 0.00 0.00 0.0 0.00 0.00 3360.0 482.5 356 0.0 3843 9.99 0.00 0.00 0.0 0.00 0.00 3354.6 488.0 360 0.0 3843 9.99 0.00 0.00 0.0 0.00 0.00 3349.1 493.5 364 0.0 3843 9.99 0.00 0.00 0.0 0.00 0.00 3343.6 499.0 368 0.0 3843 9.98 0.00 0.00 0.0 0.00 0.00 3338.1 504.5 372 0.0 3843 9.98 0.00 0.00 0.0 0.00 0.00 3332.6 510.0 376 0.0 3843 9.98 0.00 0.00 0.0 0.00 0.00 3327.1 515.4 380 0.0 3843 9.98 0.00 0.00 0.0 0.00 0.00 3321.7 520.9 384 0.0 3843 9.97 0.00 0.00 0.0 0.00 0.00 3316.2 526.4 388 0.0 3843 9.97 0.00 0.00 0.0 0.00 0.00 3310.7 531.9 392 0.0 3843 9.97 0.00 0.00 0.0 0.00 0.00 3305.2 537.4 396 0.0 3843 9.97 0.00 0.00 0.0 0.00 0.00 3299.7 542.9 400 0.0 3843 9.96 0.00 0.00 0.0 0.00 0.00 3294.2 548.3 404 0.0 3843 9.96 0.00 0.00 0.0 0.00 0.00 3288.8 553.8 408 0.0 3843 9.96 0.00 0.00 0.0 0.00 0.00 3283.3 559.3 G VOBS@013113025-Colony TrekolCSWCDENR S W Only113026In64rauon Rouung ty24hr 6/24/2014 Colony Tire 3026 MW Stormwater Infiltration Basin Routing 10-year 24hr Storm (Half Infiltration Rate) WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0,34 TIME OF CONCENTR 5.00 MIN INTENSITY 10 YR 7,231N/HR Oa = 1.16 CFS Ca = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 7 INCHES 10yr, 24hr PRECIPITATION CN = 85 S = (1000ICN)-10 S= 1Y6 Depth 0) = (P-0.2S)^2/(P-0.8S) D = 5.25 IN - li 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK TIP = [(43.5)(D)(Area)J / Op TIP = 13.96 MINUTES Storage Volume Req'd = (Op-Oa)'Tp'1.39'60 = 7,611 cu. ft. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 7.00 feel AFTER DEVELOPMENT WATERSHED AREA 140 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 16 FT RUNOFF COEF.'C' 0.76 TIME OF CONCENTR 5.00 MIN INTENSITY 10 YR 7.231N/HR Op= 7.69 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est _ IN ft) (cu ft) (cu ft) (ft) (ry) 7.00 329 0 0 0 0 0 0 8.00 676 503 503 1.0 6.2196 0 1.09 9.00 1155 916 1.418 2.0 7.2570 0.6931 1.89 10.00 1818 1,487 2,905 3.0 7,9740 1.0986 2.77 11.00 2792 2,305 5,210 4.0 8.5582 1.3863 3.78 12.00 3969 3,381 8.590 5.0 9,0584 1.6094 4.93 13.00 5363 4.666 13.256 6.0 9.4922 1.7918 6.21 14.00 6984 6.174 19.430 7.0 9.8745 1.9459 7.61 15.15 9047 8,016 27.445 8.2 10.2199 2.0980 9.15 Regression Output: ==> Ks = 427 b = 1.88 X Coefficient 6.06 G:UOBS@Ol3klW21 Colony TireY icsWCOENR SW 0n1yk13G261nfAVab0n Routing 10yQ4hr half infJ rate 6/24/2014 Colony Tire MLV Stormwater Infiltration Basin Routing 10-year 24hr Storm (Half Infiltration Rate) CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.16 cis OP= 7.69 cfs ' Infiltration rate = ;;:fie='':21:5 in1hr Tp = 14.0 min (Per Soils Report) dT = 4 min BASIN DATA Ks = 427 b= 1.88 Zo = 7.00 It Normal water elev = 7.00 It Peak Outflow= 0.00 cfs Box Weir Length = 5 ft Peak Stage = 12.03 ft Cw = 3.0 Maximum Storage = 8,925 cu ft Za = 14.00 It Control Holes: State Orifice: Dia = 0.00 in Dd = 0 in Inv = 0,00 It Cd = 0 Weir: L = 0 in Zi = 0.00 It Inv = 0.0 fl 13026 'Half of Infiltration Rate shown to prove that system can infiltrate without discharge to waive the NCDENR Ofeine Bypass S Vegetated Filter Strip requirements (Section 16.3.9. BMP Manual) Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate 4 1.5 0 7.00 0 0.00 0 0 0.00 0.0 V.V 2.7 8 4.7 349 7.89 0.00 0.00 0.0 0.00 0.00 344.0 5.5 12 7.3 1483 8.93 0.00 0.00 0.0 0.00 0.00 1474.4 8.2 16 7.3 3241 9.93 0.00 0.00 0.0 0,00 0.00 3229.6 11.0 20 5.2 4991 10.69 0.00 0.00 0.0 0.00 0.00 4977.5 13.7 24 3.6 6235 11.15 0.00 0.00 0.0 0.00 0.00 6219.0 16.5 28 2.5 7093 11.45 0.00 0.00 0.0 0.00 0.00 7073.6 19.2 32 1.7 7683 11.64 0.00 0.00 0.0 0.00 0.00 7661.5 21.9 36 1.2 8090 11.77 0.00 0.00 0.0 0.00 0.00 8065.8 24.7 40 0.8 8371 11,86 0.00 0.00 0.0 0.00 0.00 8343.5 27.4 44 0.6 8564 11.92 0.00 0.00 0.0 0.00 0.00 8533.9 30.2 48 0.4 8697 11.96 0.00 0.00 0.0 0.00 0.00 8664.3 32.9 52 0.3 8789 11.98 0.00 0.00 0.0 0.00 0.00 8753.3 35.6 56 0.2 8852 12.00 0.00 0.00 0.0 0,00 0.00 8813.8 38A 60 0.1 8896 12.01 0.00 0.00 0.0 0,00 0.00 8854.6 41.1 64 0.1 8926 12.02 0.00 0.00 0.0 0,00 0,00 8881A 43.9 68 0.1 8946 12.03 0.00 0.00 0.0 0.00 0.00 8899.8 46.6 72 0.0 8961 12.03 0.00 0.00 0.0 0.00 0.00 8911.3 49.4 76 0.0 8970 12.03 0.00 0.00 0.0 0.00 0.00 8918.3 52.1 80 0.0 8977 12.03 0.00 0.00 0.0 0.00 0.00 8922.4 54.8 84 0.0 8982 12.03 0.00 0.00 0.0 0.00 0.00 8924.3 57.6 88 0.0 8985 12.03 0.00 0.00 0.0 0,00 0.00 8924.7 60.3 92 0.0 8987 12.03 0.00 0.00 0.0 0,00 0.00 8924.2 63.1 96 0.0 8989 12.03 0.00 0.00 0.0 0.00 0.00 8923.0 65.8 100 0.0 8990 12.03 0.00 0.00 0.0 0.00 0.00 8921.3 68.5 104 0.0 8991 12.03 0.00 0.00 0.0 0.00 0.00 8919.3 71.3 10B 0.0 8991 12.03 0.00 0.00 0.0 0.00 0.00 8917.0 74.0 112 0.0 8991 12,03 0.00 0.00 0.0 0,00 0.00 8914.6 76.8 116 0.0 8992 12.03 0,00 0.00 0.0 0.00 0.00 8912A 79.5 120 0.0 8992 12.03 0.00 0.00 0.0 0.00 0.00 8909.6 82.3 124 0.0 8992 12.03 0.00 0.00 0.0 0,00 0.00 8906.9 85.0 128 0.0 8992 12.03 0.00 0.00 0.0 0.00 0.00 8904.3 87.7 132 0.0 8992 12.03 0.00 0.00 0.0 0.00 0.00 8901.6 90.5 136 0.0 8992 12.03 0.00 0.00 0.0 0.00 0.00 8898.9 93.2 140 0.0 8992 12.03 0.00 0.00 0.0 0.00 0.00 8896.2 96.0 144 0.0 8992 12.02 0.00 0.00 0.0 0.00 0.00 8893.4 98.7 148 0.0 8992 12.02 0.00 0.00 0.0 0.00 0.00 88907 101A 152 0.0 8992 12.02 0.00 0.00 0.0 0.00 0.00 8888.0 104.2 156 0.0 8992 12.02 0.00 0.00 0.0 0.00 0.00 8885.2 106.9 160 0.0 8992 12,02 0.00 0.00 0,0 0.00 0.00 8882.5 109.7 164 0.0 8992 12.02 0,00 0.00 0.0 0.00 0.00 8879.8 112.4 168 0.0 8992 12.02 0,00 0.00 0.0 0.00 0.00 8877.0 115.2 172 0.0 8992 12.02 0.00 0.00 0.0 0.00 0.00 8874.3 117.9 176 0.0 8992 12,02 0.00 0.00 0.0 0,00 0.00 8871.5 120.6 180 0.0 8992 12,02 0.00 0.00 0.0 0,00 0,00 8868S 123.4 184 0.0 8992 12.02 0.00 0,00 0.0 0.00 0,00 8866.0 126.1 188 0.0 G:U0BS@013tl3026-Co1ony Ti,.=IC 8992 WCDENR 12.02 0,00 0.00 0.0 0.00 0.00 8863.3 128.9 SWOnlyU30261nlltation Rout, 10YQ41hrhalf mfilrat. 6/24/2014 Colony Tire MLV Stormwater Infiltration Basin Routing 1302E 10-year 24hr Storm (Half Infiltration Rate) 192 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8860.6 131.6 196 0.0 8992 12.01 0.00 0.00 0.0 MO 0.00 8857.8 134.3 200 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8855.1 137.1 204 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8852.3 139.8 208 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8849.E 142.E 212 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8845.9 145.3 216 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8844.1 148.1 220 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8841.4 150.8 224 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8838.6 153.5 228 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8835.9 156.3 232 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8833.1 159.0 236 0.0 8992 12.01 0.00 0.00 0.0 0.00 0.00 8830.4 161.8 240 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8827.7 164.5 244 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8824.9 167.2 248 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8822.2 170.0 252 0.0 8992 12.00 0.00 0.00 0.0 MO 0.00 8819.4 172.7 256 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8816.7 175.5 260 0.0 8992 12M 0.00 0.00 0.0 0.00 0.00 8814.0 178.2 264 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 88112 181.0 268 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8808.5 183.7 272 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8805.7 186.4 276 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8803.0 189.2 28D 0.0 8992 12.00 0.00 0.00 0.0 0.00 0.00 8800.2 191.9 284 0.0 B992 12.00 0.00 0.00 0.0 0.00 0.00 8797.5 194.7 288 0.0 8992 11.99 0.00 0.00 Do 0.00 0.00 8794.8 197.4 292 0.0 8992 11.99 O.DO 0.00 0.0 0.00 0.00 8792.0 200.1 296 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8789.3 202.9 300 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8786.5 205.6 304 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8783.8 208.4 308 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8781.1 211.1 312 0.0 8992 11.99 0.00 0.00 0.13 0.00 0.00 8778.3 213.9 316 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8775.E 216.6 320 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8772.8 219.3 324 0.0 8992 11.99 0.00 0.00 0-0 0.00 MID 8770.1 222.1 328 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8767.3 224.8 332 0.0 8992 11.99 0.00 0.00 0.0 0.00 0.00 8764.6 227.6 336 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8761.9 230.3 340 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8759.1 233.0 344 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8756.4 235.8 348 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8753.6 238.5 352 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8750.9 241.3 356 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8748.2 244.0 360 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8745.4 246.8 364 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 6742.7 249.5 368 0.0 8992 11.98 0.00 0.00 0.0 MO 0.00 8739.9 252.2 372 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8737.2 255.0 376 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8734.4 257.7 380 0.0 8992 11.98 0.00 0.00 0.0 0.00 0.00 8731.7 260.5 384 0.0 8992 11.97 D.00 0.00 0.0 0.00 0.00 8729.0 263.2 388 0.0 8992 11.97 0.00 0.00 0.0 0.00 0.00 8726.2 265.9 392 0.0 8992 11.97 0.00 0.00 0.0 0.00 0.00 8723.5 268.7 396 0.0 8992 11.97 0.00 0.00 0.0 0.00 0.00 8720.7 271.4 400 0.0 8992 11.97 0.00 0.00 0.0 MO 0.00 8718.0 274.2 404 0.0 8992 11.97 0.00 0.00 0.0 0.00 0.00 8715.3 276.9 408 0.0 8992 11.97 0.00 0.00 0.0 0.00 0.00 8712.5 279.7 G'.UOBSVOJN3026-Colony Til.k I.WCDENR SW OnIy113W61nfilth0a, Rautin0 10y(14hr half infit rate Pusey, Steven From: Pusey, Steven Sent: Thursday, June 12, 2014 9:58 AM To: 'Monica Valsi' Subject: RE: Colony Tire Expansion Monica, Thanks for the map which was very helpful. In addition, can you send me documentation showing that the existing buildings, gravel parking, etc. were built before 1988? An old survey or plat would help to illustrate the existing BUA that is now being captured by the new infiltration basin, thus justifying the variance for the additional pavement at the front of the lot. Thanks, Steve From: Monica Valsi [mailto:monica-trippeno(cbec.rr.com] Sent: Thursday, June 12, 2014 9:13 AM To: Pusey, Steven Subject: Colony Tire Expansion Steven, As discussed earlier attached is a PDF of the drainage area going to the infiltration basin. Please contact me with any additional questions or comments. Thank you, Monica Valsi, E.I. Tripp Engineering, P.C. 419 Chestnut Street Wilmington, NC 28401 (p) 910.763.5100 (f) 910.763.5631 monica-trippeng@ec.rr.com NOTICE: This electronic correspondence and all attachments may contain privileged information intended only for the use of the addressee. Any information contained within this correspondence is provided for your convenience. No assertion of accuracy is made by Tripp Engineering, P.C. unless physical documents are obtained, sealed AND signed. User assumes all responsibility for use of this digital information. This email is free from viruses and malware because avast! Antivirus protection is active. Pusey, Steven From: Pusey, Steven Sent: Wednesday, June 11, 2014 11:44 AM To: Tripp Engineering Subject: Colony Tire Expansion Importance: High Tripp Engineering, PC Attention: Monica Valsi, El Monica, I have a couple questions about your calculations on the infiltration basin for the subject job. Please advise on the following: 1. Your design rainfall depth i .66 i�t should be 1.5 inches according to the Rules. This will change some other calculations and the numbers entered into the Supplement form, like Minimum Design Volume Required. U w 2. Bottom surface area in your Supplement form is stated as 2,758 sf. How is this calculated? Thanks, Steve .Sterlehg. PuserJ Environmental Engineer NCDENR - Division of Energy, Mineral and Land Resources 127 Cardinal Drive Ext. Wilmington, NC 28405 Ph (910) 796-7334 / Fax (910) 350-2004 http://portal.ncdenr.org/web/ir/stormwater Before printing this email, please consider your budget and the environment. E-mail correspondence to and from this address maybe subject to the North Carolina Public Records Law and maybe disclosed to third parties. i Gasmer, Jo From: Casmer, Jo Sent: Monday, April 28, 2014 11:48 AM To: 'Tripp Engineering' Subject: Colony Tire; Stormwater Permit SW8 140415 The Wilmington Regional Office of the Division of Energy, Mineral, and Land Resources (Stormwater Section) received the Stormwater Permit Application and $505.00 fee on April 17, 2014. The project will be assigned to a staff member and you will be notified if additional information is needed. Please be advised that the construction of built -upon area may not commence until the Stormwater Permit is issued. Since we do not have an email address for the applicant, we ask that you provide this status information to them. fo Casme'r Administrative Assistant for DEMLR/Stormwater Section NC Department of Environment & Natural Resources Division of Environmental Assistance & Customer Service 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7336 Fax: (910) 350-2004 Email correspondence to and from this address may be subject to the North Carolina Public Records taw and may be disclosed to third parties Project Name: Project Location: Rule(s) Ll`o Type of Permi . Density: F `j: -❑(% Subdivided?: Si �.VII IFIICICIICJD nCVIC•v a.ncannaa Received Date:jk�/ N, ��.� Accepted Date: 7 Coastal ®1995 Coastal ❑Phase II (WiRO) _Universal ❑1988 Coastal OK?) I Stream Class: Permit # (Mod or PR): PE Cert on File? SA Map ORW M Paperwork Emailed Engineer on: upplement(s) (1 original per BMP) BMP Type(s): &M with correct/original signatures (1 original per BMP except LS/VFS and swoles) application with correct/original sign tures ee Sid '- or LLC: . Auth. er SoS or letter mail Address: El OS (within 6mo) u"mail Address: to SW8 Design Engineer Owner oils Report with SHWT Note to Reviewer: 7 alculations (signed/sealed) ®No obvious errors includes common areas, etc Deed Restrictions, if subdivided: & Notarized Plans Sets etails (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc) rading OWetlands: Delineated or Wetlands ci ' y Map ayout (proposed BUA dimensions) Legend �DA Maps Project Boundaries Infiltration Wet Pond Offsite Soils Report Soils Report PE Cert for Master Lot #: SHWT: SHWT: Deed Rest for Master El Lot # Matches Master Bottom: �PP: BUA Permitted (Master): sf Visited: BUA Proposed (Offsite): sf Parmittarl Proposed: Proposed: Proposed: BUA (sf) DA (sf) PP (el) SHWT (el) Depth (ft) SA (sf) TRIPP ENGINEERING, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 • FAX: (910) 763-5631 April 17, 2014 NCDENR Division of Energy, Mineral and Land Resources 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Kelly Johnson Re: Colony Tire Expansion TE 13027 Dear Kelly: We are requesting a high density stormwater permit for Colony Tire, located at 3625 US 421 N., Wilmington. Enclosed please find the following items for review: • 2 sets of plans • $505 check • Narrative • Stormwater application — one original and one copy • Infiltration Basin Supplement • Operation and Maintenance Agreement • Calculations • USGS map • Soils Report • Secretary of State information • Copy of the Deed C:� V APR 1.7 al'1 Please review for approval and contact us with any questions, comments or if you need additional information. Thank you. Sincerely, Tripp Engineering,, P.C. AAA(Ain)41� Monica Valsi E.I. MLV:dcb Enc. ECEIVE APR 11 2014 BY: . V.. 03/19/14 Stormwater & Erosion Control Narrative Colony Tire Expansion New Hanover County, NC TE 13026 The Colony Tire Expansion is a commercial/light industrial site in New Hanover County, Parcel ID# R03200-001-030-000, owned by BCC of Edenton, LLC, and contains approximately 3.1 acres. The project is redevelopment and is located on US Hwy 421 North. No wetlands exist on the site. Colony Tire is proposing to construct one (1) building consisting of 10,000 sf, an expanded gravel area, an expanded asphalt parking area, the widening of an existing driveway, and one (1) infiltration basin for storm water management for the square footage of the new (proposed) impervious area in addition to some existing impervious area. Existing buildings, storage containers, covered shelter, asphalt and gravel areas are located on the property, most of which will remain with the exception of a small area of gravel. New impervious area for this project is 27,190 sf. The existing impervious area to remain is 59,780 sf. After project completion, the total amount of impervious area for the site will be 86,970 sf, which has a net increase of impervious area of 26,720 sf. The estimated amount of disturbed area is 2.30 acres. The drainage area for the new (proposed) impervious area in addition to some existing impervious area is 1.37 acres and provides sufficient storm water management, with an infiltration basin, to meet the State's 1.5" requirement and alternately sized for the 1-yr, 2-yr, 10- yr, 25-yr, and 100-yr storm events. Calculations have also been provided to demonstrate that the 10-yr 24-hour storm event can be infiltrated without discharging the system using an infiltration rate of one-half of the infiltration rate reported in the soils report, therefore waiving the State required off-line bypass and vegetated filter strip. Per the attached soils report, the SHWT does not occur in the upper 10 feet below site grade. The elevation of the ground surface at the bore APR 17 20% BY:----- 03/19/14 TE 13026 location is approximately elevation 15; therefore the SHWT elevation is deeper than elevation 5.0. The bottom of the infiltration basin has been set at elevation 11.0. Ultimately, the infiltration basin is sized adequately for the proposed impervious area and will drawdown in less than 1 day for the 100-yr storm event with no emergency outfall. Prior to beginning the redevelopment of the site, tree protection and temporary silt fence will be installed. Then the site will be cleared to the limits shown. After these measures occur, the infiltration basin will be constructed. The building location and gravel area will then be graded. The proposed building will be constructed and the existing gravel area will be regraded as indicated on the plan, final site grading, and stabilization of the site and landscaping. Temporary erosion control measures will remain in place until such time as when areas are stabilized. Permanent measures include permanent stands of grass. Specific measures and directions to the contractor are noted on the plans. Please refer to Sheet C2 for detail erosion control measures and construction sequence. II IN�IINIIII�I��Iilll INII INIII�II 2013003620 SFOR REGISTRATION REGISTER OF DEED' NEW HANOVERCCOUNTY�ENC BK•5 083PGp11365-113733103 2FEE $26.00 NC II�iRUafN y3aSTPAP 0 o CCE® bl E APR 17 2014 Space Above This Line For Recording Data NORTH CAROLINA GENERAL WARRANTY DEED ji e,+U.rn ib NOfbM� Ckt+e(r Prepared by M H Hood Ellis, Attorney Return to M li Hood Ellis, Attorney Excise Tax $1,300 00 Tax Parcel R03200-001-030-000 State of North Carolina, County of New Hanover THIS GENERAL WARRANTY DEED made this 16" day of January, 2013, by and between Berlin Limited Partnership, a Ohio Limited Partnership, whose mailing address is 1795 Brookwood Drive, Akron, Ohio 44313 (hereinafter referred to as "Grantor"), and BCC of Edenton, LLC, a North Carolina Limited Liability Company, whose mailing address is PO Box 827, Edenton, North Carolina 27932 (hereinafter referred to as "Grantee") WITNESSETH: That the Grantor, for a valuable consideration paid by the Grantee, the receipt of which is hereby acknowledged, has given, granted, bargained, sold, and conveyed, and by these presents does hereby give, grant, bargain, sell, and convey unto said Grantee, Grantee's successors, and assigns, all of that certain piece, parcel, or tract of land situate, lying and being in New Hanover County, State of North Carolina, and being more particularly desenbed as follows Being all of Tract I shown on the map titled "M&N Equipment Rentals, Inc. Division Part of Fleming and Royal Estate"prepared by Michael Underwood & Associates, P.A. which said map is recorded in Map Book 37, Page 85, in the Office of the Register of Deeds of New Hanover County, North Carolina. Being also the same property conveyed by James Berlin and wife, Madeline L. Berlin, to Berlin Limited Partnership, a Ohio Limited Partnership by deed dated December 16, 1998 and recorded on December 21, 1998, which deed is of record in Deed Book 2490, Page 411, of the New Hanover County Public Registry. The property herein conveyed does not include the primary residence of a Grantor. TO HAVE AND TO HOLD the above described lands and premises, together with all appurtenances thereunto belonging, or in any way appertaining, unto the Grantee, Grantee's successors, and assigns forever AND THE SAID GRANTOR COVENANTS to and with said Grantee, Grantee's successors, and assigns, that Grantor is lawfully seized in fee simple of said lands and premises, and have full right and power to convey the same to the Grantee in fee simple, and that said lands and premises are free from any and all encumbrances, except as set forth herein, and that the Grantor will warrant and defend the title against the lawful claims of all persons whomsoever, with the exception of the following Ad valorem taxes for the year 2013 and subsequent years, easements and restrictions of record, and any local, county, state, arfederal laws, ordinances, or regulations relating to zoning, environment, subdivision, occupancy, use, conso uction, or development of the subject property IN WITNESS WHEREOF, the Grantor has duly executed and sealed this document, as of the day and year first above written [REST OF PAGE INTENTIONALLY BLANK — SIGNATURE ON FOLLOWING PAGE] BERLIN LIMITED PARTNERSHIP, a Ohio Limited Partnership By: BERLIN, LLC, a Ohio Limited Liability Company, General Partner T�y Lawrence, Authorized Signatory (See Exhibit A attached) State of aa City/County of I certify that the following person personally appeared before me this day, acknowledging to me that he voluntarily signed the foregoing document for the purpose stated therein and in the capacity indicated: Terry Lawrence, Authorized Signatory of BERLIN, LLC, a Ohio Limited Liability Company, as General Partner of BERLIN LIMITED PARTNERSHIP, a Ohio Limited Partnership (See Unanimous Consent of Members and Grant of Authority to Bind Berlin, LLC, attached hereto and incorporated herein as Exhibit A.). Date January 25th 2013 JUDITH L ROMAN. Notary Public Residence • Summd County Stale Wide Junsdlctlon, Ohio My Commission Expires Nov 12,2014 w stamp must appear within F U�Sry U..1.1 FK DOCS SI RB to BCC n IUNISED W 17 M1B rpE No Itc f �� Type orPrint Name Judith L. Roman My Commission Expires 11/12/14 EXHIBIT A UNANIMOUS CONSENT OF MEMBERS AND GRANT OF AUTHORITY TO SIND BERLIN, LLC The undersigned, being all of the members of BERLIN, LLC, a limited liability company organized and operating under the laws of Ohio ('the Company"), waiving notice and acting without a meeting as provided by the laws of Ohio, hereby take the following action, effective December 19, 2012 1 The Company, as sole general partner of Berlin Limited Partnership ("the Partnership7, is authorized to purchase, sell, exchange, transfer, convey, lease, mortgage, grant a security interest in, or otherwise acquire, dispose of, or encumber real property and/or personal property on behalf of the Partnership 2, Terry Lawrence is hereby appointed as the Company's agent and is also authorized to take all such further actions as he shall deem necessary or desirable to consummate the transactions described in Item 1 above, including but not limited to the actions listed in Item 3 below Terry Lawrence may act independently, with full authority to bind the Company by himself, and any person dealing with the Company shall be entitled to rely on the actions of Terry Lawrence without further inquiry The authority hereby conferred includes but is not limited to the authority to Take all actions to effectuate the transactions described in Item 1 above on behalf of the Partnership, Execute, deliver and cause to be recorded any and all deeds or other instruments of conveyance, including but not limited to lease assignments, affidavits, certificates, tax statements, settlement statements, mortgage documents, and other documents as shall reasonably be necessary in connection with the transactions described in Item 1 above Sign, endorse, or assign any note, check, or other instrument of any nature, negotiable or non-negotiable, for deposit discount, collection, or otherwise, relating to the transactions described in Item 1 above, Receive and disburse funds, open bank accounts and investment accounts of any nature in the Company's name, and transfer funds into and out of any such account, and Take all such other actions as shall be necessary or desirable in the opinion of Terry Lawrence to carry out the transactions described herein Any person, firm, or corporation shall be fully protected in relying upon the grant of authority herein contained unless and until actual written notice of its revocation is received All parties dealing with Terry Lawrence are expressly exonerated from any duty of looking to the application of funds or property delivered to him All actions that may be taken by Terry Lawrence in connection wdh the transactions contemplated herein are hereby ratified and approved insofar as any third party is concerned. WITNESS the following authorized execution on the dates indicated below BERLIN, LLC By / Date signed mes Berlin, member STATE OF OHIO COUNTY OF The foregoing Unanimous Consent of Members and Grant of Aiiithority to bind Berlin, LLC was acknowledged before me this /? *day of LncBt t1 2DL=, by Jarnes Berlin, member of Berlin, LLC, the sole General Partner of Berlin Limited Partnership, LLC My commission expires jW, 1-P4WKNaWPubk =_,� ��,4'4 p�rbrip-&mnYtCoutly �� '= 9raroWfh,M�46aia40ho ' w Ue A+ c,,,>� wEx0=Nov 12,20iA fipr or. p",. Notary Public if> -/? - L Date signed STATE OF OHIO . COUNTYOF By_i_1L1tctiGlOr.-,i Madeline Berlin, member The foregoing Unanimous Consent of Members and Grant of Authonty o bind Berlin, LLC was acknowledged before me thisf day of,, 20%<, by Madeline Berlin, member of Berlin, LLC, the sole General Partner of Berlin Limited Partnership, LLC My commission expires .IODnHi Re-sur Notary Wdic esWRence-Summn County State WMe Junsdicwn,Onw fib- 4y Commssm Fapres Nov IZ2014 tyoW PublicT /a.,g Date signed STATE OF if/u COUNTY OF,','ureIw By t,(, /I &J'-, Robert M Berlin, member The foregoing Unanimous Consent of Members and Grant of Authority to Bind Berlin, LLC was acknowledged before me this 12day of & i4 u 1 , 20 4 by Robert M Berlin, member of Berlin, LLC, the sole General Partner of Berlin Limited Partnership, LLC My commission expires JWITH L MMW Notary POIC Stale WideJuris 0w,Otuo .for My commissionboms Nov 12,2014 4 NotaryPubic Date signed STATE OF COUNTY OF '..xu7k�r By ..' "! Robin I Kane, member The foregoing Unanimous Consent of Members and Grant of Authority to Bind Berlin, LLC was acknowledged before me this i4Y7'day of Z1&';ezk4i, 20" by Robin I Kane, member of Berlin, LLC, the sole General Partner of Berlin Limped Partnership, LLC My commission expires JWITH L, ROMAN, Notary Public Rawdence • SvTmn CcuM ;•�� '- SWd WideJuAsfton,OMo off` My CamdWon E)ItesNov IZ2DI4 Notary Public L. /oNTV: Ip E , pp TAMMY THEUSCH BEASLEY REGISTER OF DEEDS, NEW HANOVER 216 NORTH SECOND STREET WILMINGTON, NC 28401 ........................................................................................................................ Filed For Registration: Book: 01/31/2013 03:42:46 PM RE 5708 Page: 1365-1373 Document No.: 2013003620 9 PGS $26 00 NC REAL ESTATE EXCISE TAX- $1,300.00 Recorder. JOHNSON, CAROLYN State of North Carolina, County of New Hanover E(;IEI " APR 17 2014 PLEASE RETAIN YELLOW TRAILER PAGE WITH ORIGINAL DOCUMENT. *2013003620* 2013003620 March 17, 2014 Tripp Engineering, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Attention: Mr. Phil Tripp, P.E. Reference: Infiltration Testing and Seasonal High Watertable Estimate Proposed Colony Tire Expansion 3625 U.S. Highway 421 Wilmington, North Carolina RFTS Job No. 972-14 Dear Mr. Tripp: RFTS is pleased to provide testing services during the design phase of the proposed Colony Tire Expansion project located 3625 U.S. Highway 421 in Wilmington, North Carolina. Specific site grading plans had not been provided to us at the time this report was prepared. DESCRIPTION OF ACTIVITIES AND FINDINGS As requested, our staff visited the site on March 13, 2014, to perform infiltration testing and estimate the seasonal high watertable at one location identified by you. The purpose of this testing was to provide soil parameters for stormwater infiltration design. Seasonal Hiah Watertable Estimate A hand auger boring was advanced at one location to a depth of approximately 10 feet below the existing ground surface in the area proposed by the civil designer for an infiltration structure. The encountered soils were logged and visually classified by depth and a Munsell Soil Color Chart was used to determine the hue, value, and chroma of the visually distinct soil layers. Our soil logs are presented in Table 1. Soils encountered in our boring consisted entirely of interbedded clean fine to medium sands (USCS Soil Group "SP") through the boring depth of 122 inches below the existing ground surface. No distinct zones of soil cementation were encountered in the profile. Based on our experience with similar soils and comparisons of the soil coloration to the Munsell Chart, it is our opinion that seasonal high water table level does not occur in the upper 10 feet below site grade. RFTS, PLLC Committed to Xesnaisive Service 1305 3A Carolina Beach Ave N Carolina Beach. North Carolina 28428 11'1"w.rftSP11c.co"1 CE8V 910-458-5261 Tripp Engineering, P.C. PETS Job No. 972-14 Infiltration Testine March 17, 2014 Page Two Infiltration testing was performed using a model 2800 Guelph, Penneameter which is a constant -head device which operates on the Mariotte siphon principle and is referenced in ASTM D-5126. The permeameter is used to determine field saturated hydraulic conductivity in centimeters per second for soil at a specified depth. This testing involves advancing a borehole to the desired infiltration depth and introducing water at a constant head to determine the steady state flow rate from which the hydraulic conductivity can be calculated. Our testing was performed approximately 48 inches below the existing ground surface. The results of our permeamcter testing are presented in Table 2. RECOMMENDATIONS Based on the results of our field testing and soil classifications at the test location, we offer the following recommendations for stormwater infiltration design: At the test location INF-1 it is our opinion that in order to achieve the steady state flow rate obtained during our testing; the areas of infiltration galleries or other infiltration structures should introduce stormwater at approximately 48 inches below the existing ground surface elevation. For purposes of sizing the structures we reconunend an ultimate application rate of 3.0 inches per hour. These recommendations should be reviewed by appropriate regulatory authorities before finalizing the details of any civil design. CLOSURE Please find attached our field data and a sketch showing the approximate test locations. If you have any questions after reviewing this letter, please do not hesitate to contact us at your convenience. Sincerely. RIFTS, David L. Winstead gfi""Maq Field Operations Manager er�it�tt CA nLw:SOK/dhc If. Attachments • g` Al n4 .7638 F I NEF�r .i , •� " ��� 1�� Steven D. Kell. P.E. Senior Engineer NC Registration No. 17638 ECCIVE . APR 17 2014 BY: Table 1 Munsell Soil Classifications Colony Tire Expansion 3625 U.S. 1-1ighway 421 Wilmington. North Carolina RFTS Job No. 972-14 Loc Soil Description Hue Vahie Chroma Depth Comments (in.) 1 Topsoil 0-10 Yellowish Brown fine to 10YR 5 8 10-19 medium SAND Yellowish Brown fine to ToYR 5 6 19-30 medium SAND Yellowish Brown fine to lOYR 5 8 30-50 medium SAND Yellow fine to medium SAND 1 OYR 7 1 6 50-58 Very Pale Brown fine to lOYR 8 3 58-71 medium SAND Very Pale Brown fine to 1 OYR 8 2 71-99 medium SAND White tine to medium SAND 5Y 8 1 1 99-122 1 No HZO Table 2 Guelph Permeameter Test Results Colony Tire Expansion 3625 U.S. Highway 421 Wilmington, North Carolina RFTS Job No. 972-14 Location 1 Depth (in.) 48 Hf (cm) 5 Ri (cm/min) 8.0 Rfs (cm/sec) 0.133 Hz (cm) 10 R2 (cm/min) 11.4 Rs (cm/sec) 0.19 Kfs (cm/sec) 2.14x 10" Kfs (in/hr) 3.0 Definition of Terms R1.2 — Established 3 or more constant rate of water level change (cirdmin) RI& 2s — Calculated steadv state flow rates (cm/sec) Hi.2 — Maintained Head of H2O (cm) Kr, — Calculated field saturated hydraulic conductivity (cm/sec) Depth —Depth of well hole (in.) Location — Test location identification number Note: Diameter of well is 3.0 cm. T� t i� a L�- LIA rCM '0 :} .... •0.1�,r l 1 •. / AM 1pH j mwiwe �.;a"...:� 1 1` ,�.i`._ !'•, _yr ;� �'f(�t b/ �� =1 I r ;' •`' C•,,7 f(( r-e... /fit IT ti;� K{iiJ,t o y d .� cra ev •: /•.'��.. .r:, ,'7 R-. >j.l !. i`. 1�tt1 o M !%q ru , '�•. I 7," r r f' i INF-1 /+ ucYl I Legend 6 APPROXIMATE TEST LOCATION INFILTRATION TESTING AND SHWT ESTIMATE FIGURE '1 COLONY TIRE EXPANSION DRAWING NOT TO SCALE RF(S,PLLC 3625 U.S. HIGHWAY 421 DATE: 3/17/�4 1305 3A Carolina Beach Ave N WILMINGTON, NORTH CAROLINA SKETCH: DLW Carolina Beach, North Carolina 28428 Office: 910-470-7450 Soils Engineering and JOB NO. 972-14 REVIEW: SDK Testing Services I US. HIGHWAY 1421 my w.vn I v I a..2,u . z O I z I a w a� >. i OA c> r 2 V - z F wwEa�EE a:,m cccuo 0 DD FOR DRAINAGE AREA PURPOSES ONLY 03/07/2014 Colony Tire 13026 MLV CN and C Values PRE DEVELOPMENT Determine Composite CN Value from TR-55 Table 2-2'Soil Type: Sand Description HSG CN A (ac) CN x A Impervious (on -site) - 98 0.13 12.74 Wooded A 45 0.34 15.30 0.47 28.04 Composite CN Value = 60 Pre Development Composite Runoff Coefficient Description Cr A (ac) C x A Impervious 0.95 0.13 0.1235 Wooded 0.10 0.34 0.034 0.47 0.1575 Composite C Value = 0.34 POST DEVELOPMENT Determine Composite CN Value from TR-55 Table 2-2 *Soil Type: Sand Description HSG CN A (ac) CN x A Impervious - 98 1.08 105.84 Open Space (Fair) A 39 0.29 11.31 1.37 117.15 Composite CN Value = 86 Post Development Composite Runoff Coefficient Description C A (ac) C x A Impervious 0.95 1.08 1.026 Lawns, sandy soil, Flat 0.10 0.29 0.029 1.37 1.055 Composite C Value = 0.77 Total Draina a Area 59. ft. acres 59,692 1.37 Post Development Im ervious Area Land Use s . ft. I acres Proposed Impervious 47,230 1.08 Total 47,230 1.08 h impervious = 0.791 = 79.1% G:UOBS120I W 302&Colony Tirekalcs\CN 8 C Value Calcs 03/07/2014 Colony Tire 13026 MVL Simple Method - 1.5" Storage Volume Calculations L Storage Volume - Non SA Waters - Minimum Volume Required Volume of Runoff = V = (3630) (Design Rainfall Depth) (Rv) (Drainage Area) where Rv = 0.05-0.009(1,) Rv = Runoff Coefficient = storm runoff (inches) / storm rainfall (inches) IA = Impervious Fraction = Impervious portion of the drainage area (acres) / Drainage area (acres) 'A= 79.1 % Rv= 0.76 Design Rainfall Depth = 1.66 in. Drainage Area = 1.37 acres Volume Required = 6,290 ft' Volume Provided = 20.378 ft' G,\IOW2013\13026 Colony TIIeVAn\13026 Slor. a volume C.1, 1.5incb 3/19/2014 MLV Colony Tire Stormwater Infiltration Basin Routing 1-year 241fir Storm 13026 WATERSHED DATA BEFORE DEVELOPMENT WATERSHED AREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 1 YR 3.90 IN/HR Oa= 0.62 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 3.76 INCHES lyr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S= 1.63 Depth (D) _ (P-0.2S)AD(P+0.8S) D= 2.33 IN - lyr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK TIP = [(43.5)(D)(Area)] / Op TIP = 11.58 MINUTES Storage Volume Req'd = (Op-0a)'Tp-1.39-60 3,371 cu. It. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feet AFTER DEVELOPMENT WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 1 YR 3.90 IN/HR Op= 4.11 CFS DIP = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) M) (R) 11.00 2758 0 0 0 0 0 0 12.00 3854 3.306 3.306 1.0 8,1035 0 1.02 13.00 5020 4.437 7,743 2A 8.9545 0.6931 1.95 14.00 6303 5.662 13,405 3.0 9.5033 1.0986 2.97 15.00 7644 6,974 20,378 4.0 9,9222 1.3863 4.09 Regression Output: __> Ks = 3240 In = 1.31 X Coefficient 8.08 G'.VOBSV01311302 C0kuyT'letrlcs\130261nGft.t.n Rowng 1y24h, 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 1-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Ca = 0.62 cis Qp = 4.11 cfs ' infiltration rate = F, ­77-31 invhr Tp= 11.6 min (Per Soils Report) dT = 4 min BASIN DATA Basin Drawdown Time=?`3e:'0.2 days K5 = 3240 b= 1.31 Zo = 11.00 It Normal water elev = 11.00 it Peak Outflow = 0.00 cfs Box Weir Length = 0 ft Peak Stage = 12.04 it Cw = 0.0 Maximum Storage = 3,394 cu It Zcr = 0.00 ft Control Holes: State Orifice: Dia = 0.00 in Dd = 0 in Inv = 0.00 It Cd = 0 Weir: L= 0 in Zi = 0.00 it Inv = 0.0 It Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (cu it) (a) (cfs) (cfs) (cfs) (cfs) (cfs) (cu it) (cf) 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.1 0 11.00 0 0.00 0 0 0.00 0.0 46.0 8 3.2 263 11.11 0.00 0.00 0.0 0.00 0,00 171.4 91.9 12 4.1 1036 11.37 0.00 0.00 0.0 0.00 0.00 897.8 137.9 16 3.0 2020 11.65 0.00 0.00 0.0 0.00 0.00 1836.0 183.9 20 1.9 2731 11.82 0.00 0.00 0.0 0.00 0.00 2500.9 229.E 24 1.2 3184 11.92 0.00 0.00 0.0 0.00 0.00 2908.7 275.8 28 0.8 3474 11.98 0.00 0.00 0.0 0.00 0.00 3152.3 321.8 32 0.5 3659 12.01 0.00 0.00 0.0 0.00 0.00 3291.1 367.7 36 0.3 3777 12.03 0.00 0.00 0.0 0,00 0,00 3363.1 413.7 40 0.2 3852 12.04 0.00 0.00 0.0 0.00 0.00 3392.4 459.7 44 0.1 3900 12.04 0.00 0.00 0.0 0.00 0.00 3394.5 505.6 48 0.1 3931 12.03 0.00 0.00 0.0 0.00 0.00 3379.2 551.6 52 0.1 3950 12.03 0.00 0.00 0.0 0.00 0.00 3352.8 597.6 56 0.0 3963 12.02 0.00 0.00 0.0 0.00 0.00 3319.3 643.5 60 0.0 3971 12.01 0.00 0.00 0.0 0.00 0.00 3281.3 689.5 64 0.0 3976 12.00 0.00 0.00 0.0 0.00 0.00 3240.4 735.5 68 0.0 3979 11,99 0.00 0.00 0.0 0.00 0.00 3197.7 781.4 72 0.0 3981 11.98 0.00 0,00 0.0 0.00 0.00 3153.8 827.4 76 0.0 3983 11.97 0.00 0.00 0.0 0.00 0.00 3109.1 873.4 80 0.0 3983 11.96 0.00 0.00 0.0 0.00 0.00 3064.0 919.3 84 0.0 3984 11.95 0.00 0.00 0.0 0.00 0.00 3018.6 965.3 88 0.0 3984 11.94 0.00 0.00 0.0 0.00 0.00 2973.0 1011.3 92 0.0 3984 11.93 0.00 0.00 0.0 0.00 0.00 2927.2 1057.2 96 0.0 3985 11.91 0,00 0.00 0.0 0.00 0.00 2881A 1103.2 100 0.0 3985 11.90 0.00 0.00 0.0 0.00 0.00 2835.5 1149.2 104 0.0 3985 11.89 0.00 0.00 0.0 0.00 0.00 2789.6 1195.1 108 0.0 3985 11.88 0.00 0.00 0.0 0.D0 0.00 2743.7 1241.1 112 0.0 3985 11.87 0.00 0,00 0.0 0.00 0,00 2697.7 1287.1 116 DO 3985 11,86 0.00 0,00 0.0 0,00 0.00 2651.8 1333.0 120 0.0 3985 11.85 0.00 0.00 0.0 0.00 0.00 2605.8 1379.0 124 0.0 3985 11.83 0.00 0.00 0.0 0,00 0.00 2559.9 1425.0 128 0.0 3985 11.82 0.00 0.00 0.0 0.00 0.00 2513.9 1470.9 132 0.0 3985 11.81 0.00 0.00 0.0 0.00 0.00 2467.9 1516.9 136 0.0 3985 11.80 0.00 0.00 0.0 0.00 0.00 2422.0 1562.9 140 0.0 3985 11.79 0.00 0.00 0.0 0.00 0,00 2376.0 1608.8 144 0.0 3985 11.78 0.00 0.00 0.0 0.00 0,00 2330.0 1654.8 148 0.0 3985 11.77 0.00 0.00 0.0 0.00 0.00 2284.1 1700.8 152 0.0 3985 11.75 0.00 0.00 0.0 0.00 0.00 2238.1 1746.7 156 0.0 3985 11,74 0.00 0.00 0.0 0.00 0.00 2192A 1792.7 160 0.0 3985 11.73 0.00 0.00 0.0 0.00 0,00 2146.2 1838.7 164 0.0 3985 11.72 0.00 0.00 0.0 0,00 0.00 2100.2 1884.6 168 0.0 3985 11.71 0.00 0.00 0.0 0.00 0.00 2054.2 1930.6 172 0.0 3985 11,69 0.00 0.00 0.0 0.00 D.00 2008.3 1976.E 176 0.0 3985 11.68 0.00 0.00 0.0 0.00 0.00 1962.3 2022.5 180 0.0 3985 11.67 0.00 0.00 0.0 0.00 0.00 1916.3 2068.5 184 0.0 3985 11.66 0.00 0.00 0.0 0.00 0.00 1870A 2114.5 188 G:UOBSV013113026-Colony 0.0 3985 11.64 Tirelr IW130261nnlvalion Routing 11a4hr 0.00 0,00 0.0 0.00 0.00 1824A 2160.4 3/19/2014 Colony Tire MLV Stormwater Infiltration Basin Routing 3026 1-year 24hr Storm 192 0.0 3985 11.63 0.00 0.00 0.0 0.00 0.00 1778.4 2206.4 196 0.0 3985 11.62 0.00 0.00 0.0 0.00 0.00 1732.5 2252.4 200 0.0 3985 11.61 0.00 0.00 0.0 0.00 0.00 1686.5 2298.3 204 0.0 3985 11.59 0.00 0.00 0.0 0.00 0.00 1640.5 2344.3 20B 0.0 3985 11.58 0.00 0.00 0.0 0.00 0.00 1594.6 2390.3 212 0.0 3985 11.57 0.00 0.00 0.0 0.00 0.00 1548.6 2436.2 216 0.0 3985 11.56 0.00 0.00 0.0 0.00 0.00 1502.6 2482.2 220 0.0 3985 11.54 0.00 0.00 0.0 0.00 0.00 1456.7 2528.2 224 0.0 3985 11.53 0.00 0.00 0.0 0.00 0.00 1410.7 2574.1 228 0.0 3985 11.52 0.00 0.00 0.0 0.00 0.00 1364.7 2620.1 232 0.0 3985 11.50 0.00 0.00 0.0 0.00 0.00 1318.8 2666.1 236 0.0 3985 11.49 0.00 0.00 BID 0.00 0.00 1272.8 2712.0 240 0.0 3985 11.48 0.00 0.00 0.0 0.00 0.00 1226.8 2758.0 244 0.0 3985 11.46 0.00 0.00 0.0 0.00 0.00 1180.9 2804.0 248 0.0 3985 11.45 0.00 0.00 0.0 0.00 0.00 1134.9 2849.9 252 0.0 3985 11.43 0.00 0.00 0.0 0.00 0.00 1088.9 2895.9 256 0.0 3985 1142 0.00 0.00 0.0 0.00 0.00 1043.0 2941.9 260 0.0 3985 11.41 0.00 0.00 0.0 0.00 0.00 997.0 2987.8 264 0.0 3985 11.39 0.00 0.00 0.0 0.00 0.00 951.0 3033.8 268 0.0 3985 11.38 0.00 0.00 0.0 0.00 0.00 905.1 3079.8 272 0.0 3985 11.36 0.00 0.00 0.0 0.00 0.00 859.1 3125.7 276 0.0 3985 11.35 0.00 0.00 0.0 0.00 0.00 813.1 3171.7 280 0.0 3985 11.33 0.00 0.00 0.0 0.00 0.00 767.2 3217.7 284 0.0 3985 11.32 0.00 0.00 0.0 0.00 0.00 721.2 3263.6 289 0.0 3985 11.30 0.00 0.00 0.0 0.00 0.00 675.2 3309.6 292 0.0 3985 11.29 0.00 0.00 0.0 0.00 0.00 629.3 3355.6 296 0.0 3985 11.27 0.00 0.00 0.0 0.00 0.00 583.3 3401.5 300 0.0 3985 11.25 0.00 0.00 0.0 0.00 0.00 537.3 3447.5 304 0.0 3985 11.24 0.00 0.00 0.0 0.00 0.00 491.4 3493.5 308 0.0 3985 11.22 0.00 0.00 0.0 0.00 0.00 445.4 3539.4 312 0.0 3985 11.20 0.00 0.00 0.0 0.00 0.00 399.4 3585.4 316 0.0 3985 11.18 0.00 0.00 0.0 0.00 0.00 353.5 3631.4 320 0.0 3985 11.16 0.00 0.00 0.0 0.00 0.00 307.5 3677.3 324 0.0 3985 11.15 0.00 0.00 0.0 0.00 0.00 261.5 3723.3 328 0.0 3985 11.13 0.00 0.00 0.0 0.00 0.00 215.6 3769.3 332 0.0 3985 11.10 0.00 0.00 0.0 0.00 0.00 169.6 3815.2 336 0.0 3985 11.08 0.00 0.00 0.0 0.00 0.00 123.6 3861.2 340 0.0 3985 11.06 0.00 0.00 0.0 0.00 0.00 77.7 3907.2 344 0.0 3985 11.03 0.00 0.00 0.0 0.00 0.00 31.7 3953.1 348 0.0 3985 11.00 0.00 0,00 0.0 0.00 0.00 0.0 3999.1 352 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4045.1 356 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4091.0 360 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4137.0 364 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4183.0 368 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4228.9 372 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4274.9 376 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4320.9 380 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4366.8 384 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4412.8 388 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4458.8 392 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4504.7 396 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4550.7 400 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4596.7 404 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4642.6 408 0.0 3985 11.00 0.00 0.00 0.0 0.00 0.00 0.0 4688.6 G-.UOBS@013g3026-Colony Tirekalc MD26 Infiltration Routing 1yr24hr 3/19/2014 MLV Colony Tire Stormwater Infiltration Basin Routing 2-year 24hr Storm 13026 WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 2 YR 5.88 IN/HR Qa= 0.94 CFS Qa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 4.5 INCHES 2yr, 24hr PRECIPITATION CN = 86 S = (1000/CN)-10 S = 1.63 Depth (D) = (P-0.2S)A2/(P*0.8S) D= 3.00 IN- 2yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = [(43.5)(D)(Area)J / Qp Tp= 9.90 MINUTES Storage Volume Req'd = (Qp-Qa)'Tp•1.39'60 4,345 cu. ft. CALCULATE Ks AND b . SET NORMAL ELEVATION AT = 11.00 feet WATERSHEDAREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 2YR 5.881N/HR Qp= 6.20 CFS Qp = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) (ft) (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3,306 3.306 1.0 8.1035 0 1.02 13.00 5020 4,437 7,743 2.0 8.9545 0.6931 1.95 14.00 6303 5,662 13.405 3.0 9.5033 1.0986 2.97 15.00 7644 6,974 20,378 4.0 9.9222 1.3863 4.09 Regression Output: Ks = 3240 b = 1.31 X Coefficient 8.08 G'.W6S2013tl3026Colony TlreY IcM130261nlltmhon Routing 2y24hr 3/19/2014 Colony Tire MLV Stormwater Infiltration Basin Routing 3026 2-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Da = 0.94 cfs Op = 6.20 Us ' Infiltration rate = in7hr Tp= 9.9 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time days Ks = 3240 o= 1.31 Zo= 11,00 It Normal water elev, = 11.00 fl Peak Outflow = 0.00 cfs Box Weir Length = 0 It Peak Stage = 12.31 ft Cw = 0.0 Maximum Storage = 4,602 cu It Zcr= 0.00 It Control Holes: State Orifice: Dia = 0.00 in Dd= 0 in Inv= 0,00 ft Cd = 0 Weir: L = 0 in Zi = 0.00 It Inv = 0.0 ft Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (CIS) (cu ft) (tt) (cfs) lots) lots) lots) lots) (cu f) (cf) 0 D.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 2.2 0 11.00 0 0.00 0 0 0.00 0.0 46.0 8 5.7 523 11,21 0.00 0.00 0.0 0.00 0.00 431.5 91.9 12 5.5 1881 11.62 0.00 0.00 0.0 0.00 0.00 1743.1 137.9 16 3.3 3210 11.95 0.00 0.00 0.0 0.00 0.00 3026.3 183.9 20 1.9 4000 12.12 0.00 0.00 0.0 0.00 0.00 3770.6 229.8 24 1.2 4468 12.22 0.00 0.00 0.0 0.00 0.00 4191.9 275.8 28 0.7 4744 12,27 0.00 0.00 0.0 0,00 0.00 4422.3 321.8 32 0.4 4907 12.29 0.00 0.00 0.0 0.00 0.00 4539.7 367.7 36 0.2 5004 12.31 0.00 0.00 0.0 0.00 0.00 4590.4 413.7 40 0.1 5061 12,31 0,00 0.00 0.0 0.00 0.00 4601.6 459.7 44 0.1 5095 12.31 0.00 0.00 0.0 0.00 0.00 4589.4 505.6 48 D.O 5115 12.30 0,00 0.00 0.0 0.00 0.00 4563.5 551.6 52 0.0 5127 12.29 0.00 0.00 0.0 0.00 0.00 4529.3 597.6 56 0.0 5134 12.28 0.00 0.00 0.0 0.00 0.00 4490.3 643.5 60 0.0 5138 12.27 0.00 0.00 0.0 0,00 0.00 4448.5 689.5 64 0.0 5140 12.27 0.00 0.00 0.0 0.00 0.00 4405.0 735.5 68 0.0 5142 12.26 0.00 0.00 0.0 0.00 0.00 4360.5 781.4 72 0.0 5143 12.25 0.00 0.00 0.0 0.00 0.00 4315.3 827.4 76 0.0 5143 12.24 0.00 O.00 0.0 0.00 0.00 4269.9 873.4 80 0.0 5144 12.23 0.00 0.00 0.0 0.00 0.00 4224.2 919.3 84 0.0 5144 12.21 0.00 0,00 0.0 0.00 0.00 4178.4 965.3 88 0.0 5144 12.20 0.00 0,00 0.0 0,00 0.00 4132.6 1011.3 92 0.0 5144 12.19 0.00 0.00 0.0 0.00 0.00 4086.7 1057.2 96 0.0 5144 12.18 0.00 0.00 0.0 0.00 0.00 4040.7 1103.2 100 0.0 5144 12.17 0,00 0.00 0.0 0,00 0.00 3994.8 1149.2 104 0.0 5144 12.16 0,00 0.00 0.0 0.00 0.00 3948.8 1195.1 108 0.0 5144 12.15 0.00 0.00 0.0 0.00 0.00 3902.9 1241A 112 0.0 5144 12.14 0.00 0.00 0.0 0.00 0.00 3856.9 1287A 116 0.0 5144 12.13 0.00 0.00 0.0 0.00 0.00 3811.0 1333.0 120 0.0 5144 12.12 0.00 0.00 0.0 0,00 0.00 3765.0 1379.0 124 00 5144 12.11 0.00 0.00 0.0 0.00 0.00 3719.0 1425.0 128 0.0 5144 12.10 0.00 0.00 0.0 0.00 0.00 3673.1 1470.9 132 0.0 5144 12.09 0.00 0,00 0.0 0.00 0.00 3627.1 1516.9 136 0.0 5144 12.08 0.00 0.00 0.0 0,00 0.00 3581.1 1562.9 140 0.0 5144 12.07 0.00 0.00 0.0 0,00 0.00 3535.2 1608.8 144 0.0 5144 12.06 0.00 0.00 0.0 0,00 0.00 3489.2 1654.8 148 0.0 5144 12.05 0.00 0.00 0.0 0.00 0.00 3443.2 1700.8 152 0.0 5144 12,04 0.00 0.00 0.0 0.00 0.00 339T3 1746.7 156 0.0 5144 12.03 0.00 0.00 0.0 0.00 0.00 3351.3 1792.7 160 0.0 5144 12.02 0.00 0.00 0.0 0.00 0,00 3305.3 1838.7 164 0.0 5144 12.00 0.00 0.00 0.0 0.00 0.00 3259A 1884.6 168 0.0 5144 11.99 0.00 0.00 0.0 0,00 0.00 3213A 1930.6 172 0.0 5144 11.98 0.00 0.00 0.0 0.00 0.00 3167.4 1976.6 176 0.0 5144 11.97 0,00 0.00 0.0 0,00 0.00 3121.5 2022.5 180 0.0 5144 11.96 0.00 0.00 0.0 0.00 0.00 3075.5 2068.5 184 0.0 5144 11.95 0.00 0.00 0.0 0,00 0.00 3029.5 2114.5 188 00 5144 11.94 0.00 0.00 0.0 0.00 0.00 2983.6 2150 4 G.UOBS@01113026-Colony TirekaloW30261nfilinumn Routing 2yr24hr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 2-year 24hr Stom 192 0.0 5144 11.93 0.00 0.00 0.0 0.00 0.00 2937.6 2206.4 196 0.0 5144 11.92 0.00 0.00 0.0 0.00 0.00 2891.6 2252.4 200 0.0 5144 11.91 0.00 0.00 0.0 0.00 0.00 2845.7 2298.3 204 0.0 5144 11.89 0.00 0.00 0.0 0.00 0.00 2799.7 2344.3 208 0.0 5144 11.88 0.00 0.00 0.0 0.00 0.00 2753.7 2390.3 212 0.0 5144 11.87 0.00 0.00 0.0 0.00 0.00 2707.8 2436.2 216 0.0 5144 11.86 0.00 0.00 0.0 0.00 0.00 2661.8 2482.2 220 0.0 5144 11.85 0.00 0.00 0.0 0.00 0.00 2615.8 2528.2 224 0.0 5144 11.84 0.00 0.00 0.0 0.00 0.00 2569.9 2574.1 228 0.0 5144 11.83 0.00 0.00 0.0 0.00 0.00 2523.9 2620.1 232 0.0 5144 11.81 0.00 0.00 0.0 0.00 0.00 2477.9 2666.1 235 0.0 5144 11.80 0.00 0.00 0.0 0.00 0.00 2432.0 2712.0 240 0.0 5144 11.79 0.00 0.00 0.0 0.00 0.00 2386.0 2758.0 244 0.0 5144 11.78 0.00 0.00 0.0 MO 0.00 2340,0 2804.0 248 0.0 5144 11.77 0.00 0.00 0.0 0.00 0.00 2294.1 2849.9 252 0.0 5144 11.76 0.00 0.00 0.0 0.00 0.00 2248.1 2895.9 256 0.0 5144 11.74 0.00 0.00 0.0 0.00 0.00 2202.1 2941.9 260 0.0 5144 11.73 0.00 0.00 0.0 0.00 0.00 2156.2 2987.8 264 0.0 5144 11.72 0.00 0.00 0.0 0.00 0.00 2110.2 3033.8 268 0.0 5144 11.71 0.00 0.00 0.0 0.00 0.00 2064.2 3079.8 272 0.0 5144 11.70 0.00 0.00 0.0 0.00 0.00 2018.3 3125.7 276 0.0 5144 11.68 0.00 0.00 0.0 0.00 0.00 1972.3 3171.7 280 0.0 5144 11.67 0.00 0.00 0.0 0.00 0.00 1926.3 3217.7 284 0.0 5144 11.66 0.00 0.00 0.0 6.60 0.00 1880.4 3263.6 288 00 5144 11.65 0.00 0.00 0.0 0.00 0.00 1834.4 3309.6 292 0.0 5144 11.63 0.00 0.00 0.0 0.00 0.00 1788.4 3355.6 296 0.0 5144 11.62 0.00 0.00 0.0 0.00 0.00 1742.5 3401.5 300 0.0 5144 11.61 0.00 0.00 0.0 0.00 0.00 1696.5 3447.5 304 00 5144 11.60 0.00 0.00 0.0 0.00 0.00 1650.5 3493.5 308 0.0 5144 11.58 0.00 0.00 0.0 0.00 0.00 1604.6 3539.4 312 0.0 5144 11.57 0.00 0.00 0.0 0.00 0.00 1558.6 3585.4 316 0.0 5144 11.56 0.00 0.00 0.0 0.00 0.00 1512.6 3631 A 320 0.0 5144 11.54 0.00 0.00 0.0 0.00 MO 1466.7 3677.3 324 0.0 5144 11.53 0.00 0.00 0.0 0.00 0.00 1420.7 3723.3 328 0.0 5144 11.52 0.00 0.00 0.0 0.00 0.00 1374.7 3769.3 332 0.0 5144 11.51 0.00 0.00 0.0 0.00 0.00 1328.8 3815.2 336 0.0 5144 1149 0.00 0.00 0.0 0.00 MO 1282.8 3861.2 340 0.0 5144 11.48 0.00 0.00 0.0 0.00 0.00 1236.8 3907.2 344 0.0 5144 11.46 0.00 0.00 0.0 0.00 0.00 1190.9 3953.1 348 0.0 5144 11.45 0.00 0.00 0.0 0.00 0.00 1144.9 3999.1 352 0.0 5144 11.44 0.00 0.00 0.0 0.00 0.00 1098.9 4045.1 356 0.0 5144 11.42 0.00 0.00 0.0 0.00 0.00 1053.0 4091.0 360 0.0 5144 11.41 0.00 0.00 0.0 0.00 0.00 1007.0 4137.0 364 0.0 5144 11.39 0.00 0.00 0.0 0.00 0.00 961.0 4183.0 368 0.0 5144 11.38 0.00 0.00 0.0 0.00 OM 915.1 4228.9 372 0.0 5144 11.36 0.00 0.00 0.0 0.00 0.00 869.1 4274.9 376 0.0 5144 11.35 0.00 0.00 0.0 0.00 0.00 823.1 4320.9 380 0.0 5144 11.34 0.00 0.00 0.0 0.00 0.00 777.2 4366.8 384 0.0 5144 11.32 0.00 0.00 0.0 0.00 0.00 731.2 4412.8 388 0.0 5144 11.30 0.00 0.00 0.0 0.00 0.00 685.2 4458.8 392 0.0 5144 11.29 0.00 0.00 0.0 0.00 0.00 639.3 4504.7 395 0.0 5144 11.27 0.00 0.00 0.0 MO 0.00 593.3 4550.7 400 0.0 5144 11.26 0.00 0.00 00 0.00 0.00 547.3 4596.7 404 0.0 5144 11.24 0.00 0.00 0.0 0.00 0.00 5014 4642.6 408 0.0 5144 11.22 0.00 0.00 0.0 0.00 0.00 455.4 4688.6 G.UOBSQWZAI o Colony Tirakalcak13026 Infiltration Routing 2YQ4hr 3/19/2014 Colony Tire 3026 MLV Stormwater Infiltration Basin Routing 10-year 24hr Storm WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0,47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 10YR 7.231N/HR Oa= 1.16 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 7 INCHES 10yr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S = 1.63 Depth (D) = (P-0.2S)A2/(Pt0.8S) D = 5.37 IN - 10yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = [(43.5)(D)(Area)) / Op Tp= 14.38 MINUTES Storage Volume Req'd = (Op-Oa)'Tp'i-39'60 = 7,763 cu. ft. CALCULATE Ks AND 6 SET NORMAL ELEVATION AT = 11.00 feet AFTER DEVELOPMENT WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 10 YR 7.231N/HR Op= 7.63 CFS Op= POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE IRS InZ Zest (sq ft) (cu ft) (cu ft) (ft) (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3,306 3.306 1.0 8.1035 0 1,02 13.00 5020 4,437 7,743 2.0 8,9545 0.6931 1.95 14.00 6303 5,662 13,405 3.0 9.5033 1.0986 2.97 15.00 7644 6,974 20,378 4.0 9.9222 1.3863 4.09 Regression Output: Ks = 324D 6 = 1.31 X Coefficient 8,08 G.�0B512013V 3026Colony TireNcalcs113026InfflImbon Routing 10y24hr 3/19/2014 Colony Tire 13026 MLV Slormwater Infiltration Basin Routing 10-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Qa= 1.16 cfs Qp = 7.63 cfs Infiltration rate /Nhr TIP = 14.4 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time= 7775771 days Ks = 3240 b= 1.31 Zo= 11,00 It Normal water elev= 11.00 It Peak Outflow = 0.00 Ms Box Weir Length = 0 It Peak Stage = 13.07 If Cw = 0.0 Maximum Storage = 8.377 cu it Zcr= 0.00 It Control Holes: State Orifice: Dia = 0.00 in Dd = 0 in Inv = 0.00 It Cd= 0 Weir: L= 0in Zi = 0.00 ft Inv = 0.0 It Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (W ft) (it) (cfs) (cfs) (cfs) (cfs) (cfs) (cu ft c) 0 0.0 6 11.00 a o 0 0 0.00 0.0 0.0 4 1.4 0 11,00 0 0.00 0 0 0.00 0.0 46.0 8 4.5 328 11.13 0.00 0.00 0.0 0.00 0.00 235.7 91.9 12 7.1 1404 11 A9 0.00 0.00 0.0 0.00 0.00 1265.7 137.9 16 7.4 3113 11.93 0.00 0.00 0.0 0.00 0.00 2928.9 183.9 20 5.4 4887 12,32 0.00 0.00 0.0 0.00 0.00 4657.0 229.8 24 3.8 6190 12.59 0.00 0.00 0.0 0.00 0.00 5914.2 275.8 28 2.6 7098 12.76 0,00 0.00 0.0 0.00 0.00 6776.1 321S 32 1.8 7730 12.87 0,00 0.00 0.0 0.00 0.00 7362.5 367.7 36 1.3 8171 12.95 0.00 0.00 0.0 0.00 0,00 7757.1 413.7 40 0.9 8478 13.00 0.00 0.00 0.0 0.00 0.00 8018.0 459.7 44 0.6 8691 13.03 0.00 0.00 0.0 0.00 0.00 8185.8 505.E 48 0.4 8840 13,05 0.00 0.00 0.0 0.00 0.00 8288.8 551.6 52 0.3 8944 13.06 0.00 0.00 0.0 0.00 0.00 8346.5 597.6 56 0.2 9016 13,07 0.00 0.00 0.0 0,00 0,00 8372.8 643.5 60 0.1 9067 13.07 0.00 0.00 0.0 0,00 0.00 8377.2 689.5 64 0.1 9102 13.07 0.00 0.00 0.0 0.00 0.00 8366.3 735.5 68 0.1 9126 13.06 0.00 0.00 0.0 0.00 0.00 8344.8 781.4 72 0.0 9143 13.06 0.00 0,00 0.0 0.00 0,00 8315S 827.4 76 0.0 9155 1 13.05 0.00 0.00 0.0 0.00 0.00 8281.7 873.4 80 0.0 9163 13.04 0.00 0.00 0.0 0,00 0.00 8244.0 919.3 84 0.0 9169 13.04 0.00 0.00 0.0 0.00 0.00 8203.8 965.3 88 0.0 9173 13.03 0.00 0.00 0.0 0,00 0.00 8161.8 1011.3 92 0.0 9176 13.02 0.00 0.00 0.0 0.00 0.00 8118.7 1057.2 95 0.0 9178 13.01 0.00 0.00 0.0 0.00 B00 8074.6 1103.2 100 B0 9179 13.00 0.00 0.00 0.0 0,00 0.00 8030.0 1149.2 104 0.0 9180 13.00 0.00 0.00 0.0 0.00 0.00 7985.0 1195.1 108 0.0 9181 12.99 0.00 0.00 0.0 0.00 0,00 7939.7 1241.1 112 0 0 9181 12.98 0.00 0.00 0.0 0.00 0.00 7894.2 1287.1 116 0.0 9182 12.97 0.00 0.00 0.0 0.00 0.00 7848.5 1333.0 120 0.0 9182 12.96 0.00 0.00 0.0 0,00 0.00 7802.8 1379.0 124 0.0 9182 12.95 0.00 0.00 0.0 0.00 0.00 7757.0 1425.0 128 0.0 9182 12.94 0.00 0.00 0.0 0.00 0.00 7711.1 1470.9 132 0.0 9182 12.93 0.00 0,00 0.0 0.00 0.00 7665.2 1516.9 136 0.0 9182 12.92 0.00 0.00 0.0 0,00 0,00 7619.3 1562.9 140 0.0 9182 12.92 0.00 0.00 0.0 0,00 0.00 7573A 1608.8 144 0.0 9182 12A1 0.00 0.00 0.0 0,00 0,00 7527.4 1654.8 148 0.0 9182 12.90 0.00 0.00 0.0 0.00 0.00 7481.5 1700.8 152 0-0 9182 12.89 0,00 0.00 0.0 0.00 0,00 7435.5 1746.7 156 0.0 9182 12.88 0.00 0.00 0.0 0.00 0.00 7389.6 1792.7 160 0.0 9182 12S7 0.00 0.00 0.0 0.00 0.00 7343.6 1838.7 164 0.0 9182 12.86 0.00 0.00 0.0 0.00 0.00 7297.7 1884.6 168 0.0 9182 12S5 0,00 0.00 0.0 0.00 0.00 7251.7 1930.6 172 0.0 9182 12.84 0.00 0.00 0.0 0.00 0.00 7205.7 1976.6 176 0.0 9182 12,84 0.00 0.00 11.0 0.00 0.00 7159.8 2022 5 180 0.0 9182 12S3 0,00 0.00 0.0 0,00 0.00 7113S 2068.5 184 0.0 9182 12,82 0.00 0.00 0.0 0.00 0.00 7067.8 2114.5 188 0.0 9182 12,81 0.00 0.00 0.0 0,00 0.00 7021.9 2160,4 G UOBSQ01 31lX26-Colony Tirekalae lMc8 Infiltration Routing t0y24hr 3/19/2014 Colony Tire MlV Stormwater Infiltration Basin Routing 3026 10-year 24hr Storm 192 0.0 9182 12.B0 0.00 0.00 0.0 0.00 0.00 6975.9 2206.4 196 0.0 9182 12.79 0.00 0.00 0.0 0.00 0.00 6929.9 2252.4 200 0.0 9182 12.78 0.00 0.00 0.0 0.00 0.00 6884.0 2298.3 204 0.0 9182 12.77 0.00 0.00 0.0 0.00 0.00 6838.0 2344.3 208 0.0 9182 12.76 0.00 0.00 0.0 0.00 0.00 6792.0 2390.3 212 0.0 9182 12.75 0.00 0.00 0.0 0.00 0.00 6746.1 2436.2 216 0.0 9182 12.74 0.00 0.00 0.0 0.00 0.00 6700.1 2482.2 220 0.0 9182 12.74 0.00 0.00 0.0 0.00 0.00 6654.1 2528.2 224 0.0 9182 12.73 0.00 0.00 0.0 0.00 0.00 6608.2 2574.1 228 0.0 9182 12.72 0.00 0.00 0.0 0.00 0.00 6562.2 2620.1 232 0.0 9182 12.71 0.00 0.00 0.0 0.00 0.00 6516.2 2666.1 236 0.0 9182 12.70 0.00 0.00 0.0 0.00 0.00 6470.3 2712.0 240 0.0 9182 12.69 0.00 0.00 0.0 0.00 0.00 6424.3 2758.0 244 0.0 9182 12.68 0.00 0.00 0.0 0.00 0.00 6378.3 2804.0 248 0.0 9182 12.67 0.00 0.00 0.0 0.00 0.00 6332.4 2849.9 252 0.0 9182 12.66 0.00 0.00 0.0 0.00 0.00 6286.4 2895.9 256 0.0 9182 12.65 0.00 0.00 0.0 0.00 0.00 6240.4 2941.9 260 0.0 9182 12.64 0.00 0.00 Do 0.00 0.00 6194.5 2987.8 264 0.0 9182 12.63 0.00 0.00 0.0 0.00 0.00 6148.5 3033.8 268 0.0 9182 12.62 0.00 0.00 0.0 0.00 0.00 6102.5 3079.8 272 0.0 9182 12.61 0.00 0.00 0.0 0.00 0.00 6056.E 3125.7 276 0.0 9182 12.61 0.00 0.00 0.0 0.00 0.00 6010.6 3171.7 280 0.0 9182 12.60 0.00 0.00 0.0 0.00 0.00 5964.6 3217.7 284 0.0 9182 12.59 0.00 0.00 0.0 0.00 0.00 59183 3263.6 288 0.0 9182 12.58 0.00 0.00 0.0 0.00 0.00 5872.7 3309.6 292 0.0 9182 12.57 0.00 0.00 0.0 0.00 0.00 58263 3355.6 296 0.0 9182 12.56 0.00 0.00 0.0 0.00 0.00 5780.8 3401.5 300 0.0 9182 12.55 0.00 0.00 0.0 0.00 0.00 5734.8 3447.5 304 0.0 9182 12.54 0.00 0.00 0.0 0.00 0.00 5688.8 3493.5 308 0.0 9182 1253 0.00 0.00 0.0 0.00 0.00 5642.9 3539.4 312 0.0 9182 12.52 0.00 0.00 0.0 0.00 0.00 5596.9 3585.4 316 0.0 9182 12.51 0.00 0.00 0.0 0.00 0.00 5550.9 3631.4 320 0.0 9182 12.50 0.00 0.00 0.0 0.00 0.00 5505.0 3677.3 324 0.0 9182 12.49 0.00 0.00 0.0 0.00 0.00 5459.0 3723.3 328 0.0 9182 12.4E 0.00 0.00 0.0 0.00 0.00 5413.0 3769.3 332 0.0 9182 12.47 0.00 0.00 0.0 0.00 0.00 5367.1 3815.2 336 0.0 9182 12.46 0.00 0.00 0.0 0.00 0.00 5321.1 3861.2 340 0.0 9182 12.45 0.00 0.00 0.0 0.00 0.00 5275.1 3907.2 344 0.0 9182 12.44 0.00 0.00 0.0 0.00 0.00 5229.2 3953.1 348 0.0 91B2 12.43 0.00 0.00 0.0 0.00 0.00 5183.2 3999.1 352 0.0 9182 12.42 0.00 0.00 0.0 0.00 0.00 5137.2 4045.1 356 0.0 9182 12,41 0.00 0.00 0.0 0.00 0.00 5091.3 4091.0 360 0.0 9182 12.40 0.00 0.00 0.0 0.00 0.00 5045.3 4137.0 364 0.0 9182 12.39 0.00 0.00 0.0 0.00 0.00 4999.3 4183.0 368 0.0 9182 12.38 0.00 0.00 0.0 0.00 0.00 49534 4228.9 372 0.0 9182 12.37 0.00 0.00 0.0 0.00 0.00 4907.4 4274.9 376 0.0 9182 12.36 0.00 0.00 0.0 0.00 0.00 4861.4 4320.9 380 0.0 9182 12.35 0.00 0.00 0.0 0.00 0.00 4815.5 4366.8 384 0.0 9182 12.34 0.00 0.00 0.0 0.00 0.00 4769.5 4412.8 388 0.0 9182 12.33 0.00 0.00 0.0 0.00 0.00 4723.5 4458.8 392 0.0 9182 12.32 0.00 MID 0.0 0.00 0.00 4677.6 45043 396 0.0 9182 12.31 0.00 0.00 0.0 0.00 0.00 4631.6 45503 400 0.0 9182 12.30 0.00 0.00 0.0 0.00 0.00 4585.6 4596.7 404 0.0 9182 12.29 0.00 0.00 0.0 0.00 0.00 4539.7 4642.6 408 0.0 9182 12.2E 0.00 0.00 0.0 0.00 0.00 4493.7 4688.6 (3MOBS18013U3026-Colony Tilok Iwtl3B26 lnNVatlon Routing 10y,24hr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 10-year 24hr Storm (Half Infiltration Rate) WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 10 YR 7.23 IN/HR Qa = 1.16 CFS Qa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 7 INCHES 10yr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S= 1.63 Depth (D) _ (P-0.2S)"2/(P-0.8S) D = 5.37 IN - 10yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = ((43.5)(D)(Area)] / Qp Tip = 14.38 MINUTES Storage Volume Req'd = (Qp-Oa)'Tp'1.39'60 7,763 cu. It CALCULATE Ks AND b SET NORMAL ELEVATION AT 11.00 feet AFTER DEVELOPMENT WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 10 YR 7023 WHIR Op = 7.63 CFS Qp = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) (li (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3,306 3.306 1.0 8.1035 0 1.02 13.00 5020 4.437 7.743 2.0 8.9545 0.6931 1.95 14.00 6303 5,862 13.405 3.0 9.5033 1.0986 2.97 15.00 7644 6974 20,378 4.0 9,9222 1.3863 4.09 Regression Output Ks = 3240 b= 1.31 X Coefficient 8.08 G.UGBSQ013n1302FColony TirekalcaU3026 Infiltration Routing 10yQ4r hall Inlil rate 3/1912014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 10-year 24hr Storm (Half Infiltration Rate) CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.16 cfs Op = 7.63 cfs ' Infiltration rate in/hr 'Half of Infiltration Rate shown to prove that Tp = 14.4 min (Per Soils Report) system can infiltrate without discharge to waive dT = 4 min the NCDENR Offiine Bypass 8 Vegetated Filter BASIN DATA Basln Drawdown Time = ;:,' i}',. 0.94 days Strip requirements (Section 16.3.9. BMP Manual) Ks = 3240 b= 1.31 Zo= 11.00 it Normal water elev = 11.00 ft Peak Ou[Flow= 0.00 cfs Box Weir Length = 0 R Peak Stage = 13.14 it Cw = 0.0 Maximum Storage = 8,735 cu it Za = 0.00 R Control Holes: State Orifice: Dia = 0.00 in Dd= 0 in Inv = 0.00 it Cd = 0 Weir: L = 0 in Zi = 0.00 111 Inv = 0.0 It Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (cu ft) (ft) (cfs) (cfs) (cfs) (cfs) (cfs) (cu ft) (ci) 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11.00 0 0.00 0 0 0.00 0.0 23.0 8 4.5 328 11.15 0.00 0.00 0.0 0.00 0.00 281.7 46.0 12 7.1 1404 11.51 0.00 0.00 0.0 0.00 0.00 1334.6 69.0 16 7.4 3113 11.95 0.00 0.00 0.0 0.00 0.00 3020.9 91.9 20 SA 4887 12.35 0.00 0.00 0.0 0.00 0.00 4771.9 114.9 24 3.8 6190 12.61 0.00 0.00 0.0 0,00 0,00 6052.1 137.9 28 2.6 7098 12.79 0.00 0.00 0.0 0.00 0.00 6936.9 160.9 32 1.8 7730 12.91 0.00 0.00 0.0 0.00 0.00 7546.4 183.9 36 1.3 8171 12.99 0.00 0.00 0.0 0.00 0.00 7963.9 206.9 40 0.9 8478 13.05 0.00 0,00 0.0 0.00 0.00 8247.8 229.8 44 0.6 8691 13.08 0.00 0.00 0.0 0.00 0.00 8438.6 252.8 48 0.4 8840 13.11 0.00 0.00 0.0 0.00 0.00 8564.6 275.8 52 0.3 8944 13.12 0.00 0.00 0.0 0.00 0.00 8645.3 298.8 56 0.2 9016 13.13 0.00 0.00 0.0 0.00 0.00 8694.6 321.8 60 0.1 9067 13.13 0.00 0.00 0.0 0.00 0.00 8722.0 344.8 64 0.1 9102 13.14 0.00 0.00 0.0 0.00 0.00 8734.0 367.7 68 0.1 9126 13.14 0.00 0.00 0.0 0.00 0.00 8735.5 390.7 72 0.0 9143 13.14 0.00 0.00 0.0 0.00 0.00 8729.5 413.7 76 0.0 9155 13.13 0.00 0.00 0.0 0.00 0.00 8718.4 436.7 80 0.0 9163 13.13 0.00 0.00 0.0 0,00 0.00 8703.7 459.7 84 0.0 9169 13.13 0.00 0.00 0.0 0.00 0.00 8686.4 482.7 88 0.0 9173 13.12 0.00 0,00 0.0 0.00 0.00 8667.5 505.E 92 0.0 9176 13.12 0.00 0.00 0.0 0.00 0.00 8647.3 528.6 96 0.0 9178 13.12 0.00 0.00 0.0 0.00 0.00 8626.2 551.6 100 0.0 9179 13.11 0.00 0.00 0.0 It= 0.00 8604.6 574.6 104 0.0 9180 13.11 0,00 0.00 0.0 0.00 0.00 8582.6 597.6 108 0.0 9181 13A0 0.00 0.00 0.0 0,00 0.00 8560.2 620.6 112 0.0 9181 13.10 0.00 0.00 0.0 0.00 0.00 8537.7 643.5 116 0.0 9182 13.10 0.00 0.00 0.0 0,00 0,00 8515.0 666.5 120 0.0 9182 13.09 0.00 0.00 0.0 0.00 0,00 8492.3 689.5 124 0.0 9182 13.09 0.00 0.00 0,0 0.00 0.00 8469.5 712.5 128 0.0 9182 13.08 0,00 0,00 0.0 0.00 0.00 8446.6 735.5 132 0.0 9182 13.08 0.00 0.00 0.0 0.00 0.00 8423.7 758.5 136 0.0 9182 13.07 0.00 0.00 0.0 0.00 0.00 6400.7 761.4 140 0.0 9182 13.07 0.00 0.00 0.0 0.00 0.00 8377.8 804.4 144 0.0 9182 13.07 0.00 0,00 0.0 0.00 0.00 8354.8 8274 148 fro 9182 13.06 0,00 0.00 0.0 0.00 0,00 8331.9 850.4 152 0.0 9182 13.06 0.00 0.00 0.0 0.00 0.00 8308.9 873.4 156 0.0 9182 13.05 0.00 0.00 0,0 0.00 0.00 8285.9 896.4 160 0.0 9182 13.05 0.00 0.00 0.0 0.00 0.00 8262.9 919.3 164 0.0 9182 13.04 0.00 0,00 0.0 0.00 0.00 8240.0 942.3 168 0.0 9182 13.04 0.00 0.00 0.0 0.00 0.00 8217.0 965.3 172 0.0 9182 13.03 0.00 0.00 0.0 0.00 0.00 8194.0 988.3 176 TO 9182 13,03 0,00 0.00 0.0 0.00 0,00 8171.0 1011.3 180 0.0 9182 13.03 0.00 0.00 0.0 0.00 0.00 8148.0 1034.3 184 0.0 9182 13.02 0,00 0.00 0.0 0.00 0.00 8125A 1057.2 188 0.0 9182 13.02 0.00 0.00 0.0 0,00 0.00 8102.1 1080.2 G'.UOBSQ013V 3026-Colony Tire calcsV 3026 Infiltration Routing 10yQ4hr halt Intil rate 3/1912014 Colony Tire MLV Stormwater Infiltration Basin Routing 302E 10-year 24hr Storm (Half Infiltration Rate) 192 0.0 9182 13.01 0.00 0.00 0.0 0.00 0.00 8079.1 1103.2 196 0.0 9182 13.01 0,00 0.00 0.0 0.00 0.00 8056.1 1126.2 200 0.0 9182 13.00 0.00 0.00 0.0 0.00 0.00 8033.1 1149.2 204 0.0 9182 13.00 0.00 0.00 0.0 0.00 0,00 8010.1 1172.2 208 0.0 9182 13.00 0,00 0.00 0.0 0.00 0.00 7987.2 1195.1 212 0.0 9182 12.99 0.00 0.00 0.0 0.00 0.00 7964.2 1218,1 216 0.0 9182 12,99 0.00 0.00 0.0 0.00 0.00 7941.2 1241.1 220 0.0 9182 12.98 0,00 0.00 0.0 0.00 0.00 7918.2 1264.1 224 0.0 9182 12.98 0.00 0.00 0.0 0.00 0.00 7895.2 1287.1 228 0.0 9182 12,97 0.00 0.00 0.0 0.00 0.00 7972.2 1310.1 232 0.0 9182 12.97 0.00 0.00 0.0 0.00 0.00 7849.3 1333.0 236 0.0 9182 12.96 0.00 0.00 0.0 0.00 0.00 7826.3 1356.0 240 0.0 9182 12.96 0.00 0.00 0.0 0.00 0,00 7803.3 1379.0 244 0.0 9182 12.96 0.00 0.00 0.0 0.00 0.00 7780.3 1402.0 248 0.0 9182 12.95 0.00 0.00 0.0 0.00 MID 7757.3 1425.0 252 0.0 9182 12.95 0.00 0.00 0.0 0.00 0.00 7734.3 1448.0 256 0.0 9182 12.94 0.00 0.00 0.0 0.00 0.00 7711A 1470.9 260 0.0 9182 12.94 0.00 0.00 0.0 0.00 0.00 7688.4 1493.9 264 0.0 9182 12.93 0.00 0.00 0.0 0.00 0.00 7665.4 1516.9 268 0.0 9182 12.93 0.00 0.00 0.0 0.00 0.00 7642.4 1539.9 272 0.0 9182 12.92 0.00 0.00 0.0 0.00 0,00 7619.4 1562.9 276 0.0 9182 12.92 0.00 0.00 0.0 0.00 MID 7596.4 1585.9 280 0.0 9182 12.92 0.00 0.00 0.0 0.00 0.00 7573.5 1608.8 284 0.0 9182 12.91 0.00 0,00 0.0 0.00 &00 7550.5 1631.8 288 0.0 9182 12.91 0.00 0.00 0.0 0.00 0.00 7527.5 1654.8 292 0.0 9182 12.90 0.00 0.00 0.0 0.00 0.00 7504.5 1677.8 296 0.0 9182 12.90 0,00 0.00 0.0 0.00 0.00 7481.5 1700.8 300 0.0 9182 12.89 0.00 0.00 0.0 0.00 0.00 7458.5 1723.8 304 0.0 9182 12.89 0.00 0.00 0.0 0.00 0.00 7435.6 1746.7 308 0.0 9182 12,88 0.00 0.00 0.0 0.00 0.00 7412.6 1769.7 312 0.0 9182 12,88 0.00 0.00 0.0 0.00 0.00 7389.6 1792.7 316 0.0 9182 12.88 0.00 0.00 0.0 0.00 0.00 7366.6 1815.7 320 0.0 9182 12.87 0.00 0.00 0.0 0.00 0,00 7343.E 1838.7 324 0.0 9182 12,87 0,00 0.00 0.0 0.00 0.00 7320.6 1861.7 328 0.0 9182 12,86 0.00 0.00 0.0 0.00 0.00 7297.7 1884.6 332 0.0 9182 12.86 0.00 0.00 0.0 0.00 0.00 7274.7 1907.6 336 0.0 9182 12,85 0,00 0.00 0.0 0.00 0.00 7251.7 1930.E 340 0.0 9182 12.85 0.00 0,00 0.0 0.00 0.00 7228.7 1953.6 344 0.0 9182 12.84 0.00 0.00 0.0 0.00 0.00 7205.7 1976.6 348 0.0 9182 12,84 0,00 0.00 0.0 0.00 0.00 7182.7 1999.6 352 0.0 9182 12.84 0.00 0.00 0.0 0.00 0.00 7159.8 2022.5 356 0.0 9182 12.83 0,00 0,00 0.0 0.00 0.00 7136.8 2045.5 360 0.0 9182 12.83 0.00 0.00 0.0 0.00 0.00 7113.8 2068.5 364 0.0 9182 12.82 0.00 0,00 0.0 0.00 0,00 7090.8 2091.5 368 13.0 9182 1232 0.00 0.00 0.0 0.00 0.00 7067.8 2114.5 372 0.0 9182 12.81 0.00 0.00 0.0 0.00 0.00 7044.8 2137.5 376 0.0 9182 12.81 0,00 0.00 0.0 0.00 0.00 7021.9 2160.4 380 0.0 9182 12.80 0,00 0,00 0.0 0.00 0,00 6998.9 2183.4 384 0.0 9182 12.80 0.00 0.00 0.0 0.00 0.00 6975.9 2206.4 388 0.0 9182 12.79 0,00 0.00 0.0 0.00 0.00 6952.9 2229.4 392 0.0 9182 12.79 0.00 0.00 0.0 0.00 0.00 6929.9 2252 4 396 0.0 9182 12,79 0.00 0.00 0.0 0.00 0.00 6906.9 2275.4 400 0.0 9182 12.78 0.00 0.00 0.0 0.00 0.00 6884.0 2298.3 404 0.0 9182 1238 0,00 0,00 0.0 0.00 0.00 6861.0 23213 408 0.0 9182 12.77 0.00 0.00 0.0 0.00 0.00 6838.0 2344.3 G VOB6612013%130Y Colony TlreY IWI3026 Infiltration Routing 10y24hr half ofil ram 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 25-year 24hr Storm WATERSHED DATA BEFORE DEVELOPMENT WATERSHED AREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 25 YR 8.15 IN/HR Cal = 1.30 CFS Dar = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 8.05 INCHES 25yr, 24hr PRECIPITATION CN= 86 S = (1000/Cf,l S= 1.63 Depth (D) _ (P-0.2S)^2/(P-0.8S) D = 6,38 IN - 25yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = [(43.5)(D)(Area)l / Qp Tp= 15.17 MINUTES Storage Volume Req'd = (Qp-Qa)'Tp'1.39'60 9,231 cu. ft. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feet AFTER DEVELOPMENT WATERSHEDAREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 25 YR 8.15 IN/HR Qp= 8.60 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) (ft) (ft) 11.00 2758 0 0 0 0 0 0 12,00 3854 3.306 3.306 1.0 8.1035 0 1.02 13.00 5020 4,437 7,743 2.0 8.9545 0,6931 1.95 14.00 6303 5,662 13,405 3.0 9.5033 1.0986 2.97 15.00 7644 6,974 20,378 4.0 9.9222 1.3663 4.09 Regression Output: Ks = 3240 to = 1.31 X Coefficient 8.08 G.UOBSV013\13026Cdony Tuek !k A13026 Infiltration Routing 25y:14hr 3/19/2014 Colony Tire 3026 MLV Stormwater Infiltration Basin Routing 25-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.30 cis Op = 8.60 cfs ' Infiltration rate = in/hr Tp = 15.2 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time = ,-1c' 056 days Ks = 3240 b = 1.31 Zo = 11.00 It Normal water elev = 11.00 it Peak Outflow = 0.00 cfs Box Weir Length = 0 it Peak Stage = 13.38 it Cw = 0.0 Maximum Storage = 10,048 cu it Zcr= 0.00 ft Control Holes'. State Onfice: Dia = 0.00 in Dd= 0 in Inv= 0.00 It Cd= 0 Weir L= 0in Zi = 0.00 It Inv = 0.0 It Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (cu ft) (ft) (cfs) (cfs) (cfs) (cfs) (cfs) (cu ft) (ci) 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11.00 0 0.00 0 0 0.00 0.0 46.0 6 4.7 334 11.14 0.00 0.00 0.0 0.00 0.00 242.2 91.9 12 7.7 1454 11.50 0.00 0.00 0.0 0.00 0.00 1316.3 137.9 16 8.5 3303 11.97 0.00 0.00 0.0 0.00 0.00 3119.1 183.9 20 6.7 5351 12.42 0.00 0.00 0.0 0.00 0.00 5121.4 229 B 24 4.8 6965 12.74 0.00 0.00 0.0 0.00 0.00 6689.1 275.8 28 3.4 8110 12.96 0.00 0.00 0.0 0.00 0.00 7788.5 321.8 32 2.4 8923 13.10 0.00 0.00 0.0 0.00 0.00 8555.5 367.7 36 1.7 9500 13.20 0,00 0.00 0.0 0.00 0,00 9086.7 413.7 40 1.2 9910 13.27 0.00 0.00 0.0 0.00 0.00 9450.3 459.7 44 0.9 10201 13.31 0.00 0.00 0.0 0.00 0.00 9695.1 505.6 48 0.6 10407 13.34 0.00 - 0.00 0.0 0.00 0.00 9855.5 551.6 52 0A 10554 13.36 0.00 0.00 0.0 0,00 0.00 9956.1 5976 56 0.3 10658 13.37 0.00 0.00 0.0 0.00 0.00 10014.1 643.5 60 0.2 10731 13.38 0.00 0.00 0.0 0.00 0.00 10041.9 689.5 64 0.2 10784 13.38 0.00 0.00 0.0 0.00 0.00 10048.4 735.5 fib 0.1 10821 13.38 0.00 0.00 0.0 0.00 0.00 10039.6 781.4 72 0.1 10847 13,37 0,00 0.00 O.0 0.00 0.00 10020.0 827.4 76 0A 10866 13.37 0.00 0.00 0.0 0.00 0,00 9992.8 873.4 80 0.0 10879 13.36 0.00 0.00 0.0 0.00 0.00 9960.1 919.3 84 0.0 10889 13.36 0,00 0.00 0.0 0.00 0.00 9923.6 965.3 88 0.0 10896 13.35 0.00 0.00 0.0 0.00 0.00 9884.3 1011.3 92 0.0 10900 13.34 0.00 0.00 0.0 0.00 0.00 9843.1 1057.2 96 0.0 10904 13.33 0.00 0.00 0.0 0.00 0.00 9800.5 1103.2 100 0.0 10906 13,33 0.00 0.00 00 0,00 0.00 9757.0 1149.2 104 0.0 10908 13,32 0,00 0.00 0.0 0.00 0,00 9712.7 1195.1 108 0.0 10909 13.31 0.00 0.00 0.0 0,00 0,00 9667.9 1241.1 112 0.0 10910 13.30 0.00 0.00 0.0 0,00 0.00 9622.8 1287A 116 0.0 10910 13.29 0.00 0.00 0.0 0.00 0,00 9577.5 1333.0 120 0.0 10911 13.28 0.00 0.00 0.0 0.00 0.00 9531.9 1379.0 124 0.0 10911 13.28 0.00 0.00 0.0 0.00 0.00 9486.3 1425.0 128 0.0 10911 13.27 0.00 0.00 0.0 0.00 0.00 9440.5 1470.9 132 0.0 10912 13.26 0,00 0.00 0.0 0.00 0.00 9394.7 1516.9 136 0.0 10912 13.25 0.00 0.00 0.0 0.00 0.00 9348.9 1562.9 140 0.0 10912 13.24 0.00 0.00 0.0 0.00 0.00 9303.0 1608.8 144 0.0 10912 13.23 0.00 0.00 0.0 0.00 0.00 9257.1 1654.8 148 0.0 10912 13.23 0.00 0,00 0.0 0.00 0.00 9211.1 1700.8 152 0.0 10912 13.22 0.00 0.00 0.0 0.00 0.00 9165.2 1746.7 156 0.0 10912 13.21 0,00 0.00 0.0 0.00 0.00 9119.2 1792.7 160 0.0 10912 13.20 0.00 0.00 0.0 0.00 0.00 9073.3 1838.7 164 0.0 10912 13.19 0.00 0.00 0.0 0.00 0.00 9027.3 1884.6 168 0.0 10912 13,18 0.00 0.00 0.0 0.00 0.00 8981.4 1930.6 172 0.0 10912 13.17 0.00 0.00 0.0 0.00 0,00 8935.4 1976.6 176 0.0 10912 13.17 000 0.00 0.0 0.00 0.00 8889.4 20225 180 0.0 10912 13,16 0.00 0.00 0.0 0.00 0,00 8843.5 2065.5 184 0.0 10912 13.15 0.00 0.00 0.0 0.00 0.00 8797.5 2114.5 188 0.0 10912 13.14 0.00 0.00 0.0 0.00 0.00 8751.6 2160.4 GM0BS2013t1026-Colony Tirelcakstl 3026 Infiltration Routing 25y04hr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 25-year 24hr Storm 192 0.0 10912 13.13 0.00 0.00 0.0 0.00 0.00 8705.6 2206.4 196 0.0 10912 13.12 0.00 0.00 0.0 0.00 0.00 8659.6 2252.4 200 0.0 10912 13.11 0.00 0.00 0.0 0.00 0.00 8613.7 2298.3 204 0.0 10912 13.11 0.00 0.00 0.0 0.00 0.00 8567.7 2344.3 208 0.0 10912 13.10 0.00 0.00 0.0 0.00 0.00 8521.7 23901 212 0.0 10912 13.09 0.00 0.00 0.0 0.00 0.00 B475.8 2436.2 216 0.0 10912 13.08 0.00 0.00 0.0 0.00 0.00 8429.8 2482.2 220 0.0 10912 13.07 0.00 0.00 0.0 0.00 0.00 8383.8 2528.2 224 0.0 10912 13.06 0.00 0.00 0.0 0.00 0.00 8337.9 2574.1 228 0.0 10912 13.05 0.00 0.00 0.0 0.00 0.00 8291.9 2620.1 232 0.0 10912 13.04 0.00 0.00 0.0 0.00 0.00 8245.9 2666.1 236 0.0 10912 13.04 0.00 0.00 0.0 0.00 0.00 8200.0 2712.0 240 0.0 10912 13.03 0.00 0.00 0.0 0.00 0.00 8154.0 2758.0 244 0.0 10912 13.02 0.00 0.00 0.0 0.00 0.00 810&0 2804.0 248 0.0 10912 13.01 0.00 0.00 0.0 0.00 0.00 8062.1 2849.9 252 0.0 10912 13.00 0.00 0.00 0.0 0.00 0.00 8016.1 2895.9 256 0.0 10912 12.99 0.00 0.00 0.0 0.00 0.00 7970.1 2941.9 260 0.0 10912 12.98 0.00 0.00 0.0 0.00 0.00 7924.2 2987.8 264 0.0 10912 12.97 0.00 0.00 0.0 0.00 0.00 7878.2 3033.8 268 0.0 10912 12.97 0.00 0.00 0.0 0.00 0.00 7832.2 3079.8 272 0.0 10912 12.96 0.00 0.00 0.0 0.00 0.00 7786.3 3125.7 276 0.0 10912 12.95 0.00 0.00 0.0 0.00 0.00 7740.3 3171.7 280 0.0 10912 12.94 0.00 0.00 0.0 0.00 0.00 7694.3 3217.7 284 0.0 10912 12.93 0.00 0.00 0.0 0.00 0.00 7648.4 3263.E 288 0.0 10912 12.92 0.00 0.00 0.0 0.00 0.00 7602.4 3309.6 292 0.0 10912 12.91 0.00 0.00 0.0 0.00 0.00 7556.4 3355.6 296 0.0 10912 12.90 0.00 0.00 0.0 0.00 0.00 7510.5 3401.5 300 0.0 10912 12.89 0.00 0.00 0.0 0.00 0.00 7464.5 3447.5 304 0.0 10912 12.89 0.00 0.00 0.0 0.00 0.00 7418.5 3493.5 308 0.0 10912 12.88 0.00 0.00 0.0 0.00 0.00 7372.6 3539.4 312 0.0 10912 12.87 0.00 0.00 0.0 0.00 0.00 7326.6 3585.4 316 0.0 10912 12.86 0.00 0.00 0.0 0.00 0.00 7280.6 3631.4 320 0.0 10912 12.85 0.00 0.00 0.0 0.00 0.00 7234.7 3677.3 324 0.0 10912 12.84 0.00 0.00 0.0 0.00 0.00 7188.7 3723.3 328 0.0 10912 12.83 0.00 0.00 0.0 0.00 0.00 7142.7 3769.3 332 0.0 10912 12.82 0.00 0.00 0.0 0.00 0.00 7096.8 3815.2 336 0.0 10912 12.81 0.00 0.00 0.0 0.00 0.00 7050.8 3861.2 340 0.0 10912 12.80 0.00 0.00 0.0 0.00 0.00 7004.8 3907.2 344 0.0 10912 12.80 0.00 0.00 0.0 0.00 0.00 6958.9 3953.1 348 0.0 10912 12.79 0.00 0.00 0.0 0.00 0.00 6912.9 3999.1 352 0.0 10912 12.78 0.00 0.00 0.0 0.00 0.00 6866.9 4045.1 356 0.0 10912 12.77 0.00 0.00 0.0 0.00 0.00 6821.0 4091.0 360 0.0 10912 12,76 0.00 0.00 0.0 0.00 0.00 6775.0 4137.0 364 0.0 10912 12.75 0.00 0.00 0.0 0.00 0.00 6729.0 4183.0 368 0.0 10912 12.74 0.00 0.00 0.0 0.00 0.00 6683.1 4228.9 372 0.0 10912 12.73 0.00 0.00 0.0 0.00 0.00 6637.1 42749 376 0.0 10912 12.72 0.00 0.00 0.0 0.00 0.00 6591.1 4320.9 380 0.0 10912 12.71 0.00 0.00 0.0 0.00 0.00 6545.2 4366.8 384 0.0 10912 12.70 0.00 0.00 0.0 0.00 0.00 5499.2 4412.8 388 0.0 10912 12.69 0.00 0.00 0.0 0.00 0.00 6453.2 4458.8 392 0.0 10912 12.69 0.00 0.00 0.0 0.00 0.00 6407.3 4504.7 396 0.0 10942 12.68 0.00 0.00 0.0 0.00 0.00 6361.3 4550.7 400 0.0 10912 12.67 0.00 0.00 0.0 0.00 0.00 6315.3 4596.7 404 0.0 10912 12.66 0.00 0.00 0.0 0.00 0.00 6269.4 4642.E 408 0.0 10912 12.65 0.00 0.00 0.0 0.00 0.00 6223.4 4688.6 G V 013WO 31302GColony Tlletr IuV 30261nfilvation Routing 25yr24hr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 50-year 24hr Storm WATERSHED DATA WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 50YR 8.871N/HR Qa = 1.42 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 9 INCHES 50yr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S= 1.63 Depth (D) _ (P-0.2S)A21(P.0.8S) D = 7.30 IN - 50yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK TIP = [(43.5)(D)(Area)) / Qp TIP = 15.96 MINUTES Storage Volume Req'd = (Qp-Qa)'Tp'1.39'60 = 10,567 cu. It. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feel AFTER DEVELOPMENT WATERSHED AREA 1,37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 50 YR 8,871N/HR Qp= 9.36 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In InZ Zest (sq ft) (cu ft) (cu ft) (tt) (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3,306 3,306 1.0 8.1035 0 1.02 13.00 5020 4,437 7,743 2.0 8.9545 0.6931 1.95 14.00 6303 5.662 13.405 3.0 9.5033 1.0986 2.97 15.00 7644 6,974 20.378 4.0 9.9222 1.3863 4.09 Regression Output: __> Ks = 3240 b= 1.31 X Coefficient 8.08 G'.U0B512013%l X2&Co mTuelr wl30261nfiltratbn RwUng 50y24hr 309/2014 Colony Tire MLV 302E S(ormwater Infiltration Basin Routing 50-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.42 cfs Qp = 9.36 cfs ' Infiltration rate 31 in7hr Tip = 16.0 min (Per Soils Report) dT = 4 min BASIN DATA Basin Drawdown Time= 7=;$i0:64 days Ks = 3240 b = 1.31 Zo = 11.00 It Normal water elev = 11.00 ft Peak Outflow= 0.00 cfs Box Weir Length = 0 ft Peak Stage = 13.65 ft Cw= 0.0 Maximum Storage= 11,578 cu ft Zcr= 0.00 ft Control Holes' State Orifice: Dia = 0.00 in Dd = 0 in Inv = 0.00 ft Cd = 0 Weir: L = 0 in Zi = 0.00 It Inv = 0.0 ft Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (cu ft) (ft) (cfs) (cfs) (cfs) (cfs) (cfs) (cu h) (op 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11.00 0 0.00 0 0 0,00 0.0 46.0 8 4.7 330 11.14 0.00 0.00 0.0 0.00 0.00 238.6 91.9 12 8.0 1458 11.50 0.00 0.00 0.0 0.00 0.00 1320.0 137.9 16 9.4 3380 11.99 0.00 0.00 0.0 0.00 0.00 3195.6 183.9 20 8.0 5625 12.48 0.00 0.00 0.0 0,00 0.00 5395.3 229.8 24 5.7 7536 12.85 0.00 0.00 0.0 0.00 0.00 7260.4 275.8 28 4.2 8916 13.11 0.00 0.00 0.0 0.00 0.00 8594.1 321.8 32 3.0 9912 13.29 0.00 0,00 0.0 0.00 0.00 9544.2 367.7 36 2.2 10631 13.41 0.00 0.00 0.0 0.00 0.00 10217.2 413.7 40 1.6 11150 13.49 0.00 0.00 0.0 0.00 0.00 10690.3 459.7 44 1.1 11525 13.55 0.00 0.00 0.0 0.00 0.00 11019.1 505.6 48 0.8 11795 13.59 0.00 0.00 0.0 0.00 0.00 11243.7 551.6 52 0.6 11991 13.62 0.00 0.00 0.0 0.00 0.00 11393.0 597.6 56 0.4 12132 13.64 0.00 0.00 0.0 0.00 0.00 11488.0 643.5 60 0.3 42233 13.65 0.00 0.00 0.0 0.00 0.00 11543.9 689.5 64 0.2 12307 13.65 0.00 0.00 0,0 0,00 0.00 11571.4 735.5 68 0.2 12360 13.65 0.00 0.00 0.0 0.00 0.00 11578 4 781.4 72 0.1 12398 13.65 0.00 0.00 0.0 0.00 0,00 11570.8 827.4 76 0.1 12426 13.65 0,00 0.00 0,0 0,00 0.00 11552.5 873.4 80 0.1 12446 13.64 0,00 0.00 0.0 0,00 0.00 11526A 919.3 84 0.0 12460 13.64 0.00 0.00 0.0 0.00 0.00 11494.9 965.3 88 0.0 12471 13.63 0.00 0.00 0.0 0.00 0.00 11459.3 1011,3 92 0.0 12478 13.62 0.00 0.00 0.0 0,00 0.00 11420.9 1057.2 96 0.0 12484 13.62 0.00 0.00 0.0 0.00 0,00 11380.3 1103.2 100 0.0 12487 13.61 0.00 0.00 0.0 0.00 0.00 11338.3 1149.2 104 0.0 12490 13.60 0.00 0.00 0.0 0.00 0,00 11295.1 1195.1 108 0.0 12492 13.59 0.00 0,00 0.0 0.00 0.00 11251.2 1241.1 112 0.0 12494 13.59 0.00 0.00 0.0 0.00 0.00 11206.7 1287.1 116 0.0 12495 13.58 0.00 0.00 0.0 0.00 0.00 11161.8 1333.0 120 0.0 12496 13.57 0.00 0.00 0.0 0.00 0.00 11116.6 1379.0 124 0.0 12496 13.56 0.00 0.00 0.0 0.00 0.00 11071.2 1425.0 128 0.0 12497 13.55 0.00 0.00 0.0 0.00 0.00 11025.6 1470.9 132 0.0 12497 13.55 0.00 0.00 0.0 0,00 0.00 10979.9 1516.9 136 0.0 12497 13.54 0.00 0.00 0.0 0.00 0.00 10934.2 1562A 140 0.0 12497 13.53 0,00 0.00 0.0 0.00 0.00 10888.4 1608.8 144 0.0 12497 13.52 0.00 0.00 0.0 0,00 0.00 10842.5 1654.8 148 0.0 12497 13.51 0.00 0,00 0.0 0.00 0.00 10796.6 1700.8 152 0.0 12497 13,51 0.00 0.00 0.0 0.00 0.00 10750.7 1746.7 156 0.0 12497 13.50 0.00 0.00 0.0 0.00 0.00 10704.8 1792.7 160 0.0 12498 13.49 0.00 0.00 0,0 0.00 0.00 10658.9 18387 164 0.0 12498 13.48 0.00 0.00 0.0 0.00 0.00 10612.9 1884.6 168 0.0 12498 13,47 0.00 0.00 0.0 000 0.00 10567.0 1930.E 172 0.0 12498 13.46 0,00 0.00 0.0 0,00 0.00 10521.0 1976.6 175 0.0 12498 13.46 0.00 0.00 0.0 0,00 0.00 10475.0 2022.5 180 0.0 12498 13.45 0.00 0,00 0.0 0.00 0,00 10429.1 2068.5 184 0.0 12498 13.44 0.00 0.00 0.0 0.00 0.00 10383.1 2114.5 188 0.0 12498 13.43 0.00 0.00 0.0 0.00 0.00 10337.2 2160.4 G U08S@013113026-Colony nrevalcstl3026 Infiltration Routing 50y24hr 3/19/2014 Colony Tire 302E MLV Stormwater Infiltration Basin Routing 50-year 2411r Storm 192 0.0 12498 13.42 0.00 0.00 0.0 0.00 0,00 10291.2 22064 196 0.0 12498 13.41 0.00 0.00 0.0 0,00 0.00 10245.2 2252.4 200 0.0 12493 13.41 0.00 0.00 0.0 0.00 0.00 10199.3 2298.3 204 0.0 12498 13.40 0.00 0.00 0.0 0.00 0.00 10153.3 2344.3 208 0.0 12498 13.39 0.00 0.00 0.0 0.00 0.00 10107.3 2390.3 212 0.0 12498 13.38 0.00 0.00 0.0 0.00 0,00 100614 2436.2 216 0.0 12498 13.37 0.00 0.00 0.0 0.00 0.00 10015.4 2482.2 220 0.0 12498 13,36 0.00 0.00 0.0 0.00 0.00 9969.4 2528.2 224 0.0 12498 13.36 0.00 0.00 0.0 0.00 0.00 9923.5 2574.1 228 0.0 12498 13.35 0.00 0.00 0.0 0.00 0.00 9877.5 2620.1 232 0.0 12498 13.34 0.00 0.00 0.0 0.00 0.00 9831.5 2666.1 236 0.0 12498 13.33 0.00 0.00 0.0 0.00 0.00 9785.6 2712.0 240 0.0 12498 13.32 0.00 0.00 0.0 0,00 0.00 9739.6 2758.0 244 0.0 12498 13.31 0.00 0.00 0.0 0.00 0.00 9693.6 2804.0 248 0.0 12498 13.31 0.00 0.00 0.0 0.00 0.00 9647.7 2849.9 252 0.0 12498 13.30 0.00 0.00 0.0 0.00 0.00 9601.7 2895.9 256 0.0 12498 13.29 0.00 0.00 0.0 0.00 0.00 9555.7 2941.9 260 0.0 12498 13.28 0.00 0.00 0.0 0.00 0.00 9509.8 2987.8 264 0.0 12498 13.27 0.00 0.00 0.0 0.00 0.00 9463.8 3033.8 268 0.0 12498 13.26 0.00 0.00 0.0 0.00 0.00 9417.8 3079.8 272 0.0 12498 13.26 0.00 0.00 0.0 0.00 0.00 9371.9 3125.7 276 0.0 42498 13.25 0.00 0.00 0.0 0.00 0.00 9325.9 3171.7 280 0.0 12498 13.24 0.00 0.00 0.0 0.00 0.00 9279.9 3217.7 284 0.0 12498 13.23 0.00 0.00 0,0 0.00 0.00 9234.0 3263.6 288 0.0 12498 13.22 0.00 0.00 0.0 0.00 0.00 9188.0 3309.6 292 0.0 12498 13.21 0.00 0.00 0.0 0.00 0.00 9142.0 3355.E 296 0.0 12498 13.20 0.00 0.00 0.0 0.00 0.00 9096.1 3401.5 300 0.0 12498 13.20 0.00 0.00 0.0 0,00 0,00 9050.1 3447.5 304 0.0 12498 13.19 0.00 0.00 0.0 0.00 0,00 9004.1 3493.5 308 0.0 12498 13.18 0.00 0.00 0.0 0.00 0,00 8958.2 3539.4 312 0.0 12498 13.17 0.00 0.00 0.0 0.00 0.00 8912.2 3585.4 316 0.0 12498 13.16 0,00 0.00 0.0 0.00 0.00 8866.2 3631.4 320 0.0 12498 13.15 0.00 0.00 0.0 MO 0.00 8820.3 3677.3 324 0.0 12498 13.14 0,00 0.00 0.0 0.00 0.00 8774.3 3723.3 328 0.0 12498 13.14 0.00 0.00 0.0 0.00 0.00 8728.3 3769.3 332 0.0 12498 13,13 0.00 0.00 0.0 0,00 0.00 8682.4 3815.2 336 0.0 12498 13.12 0.00 0.00 0.0 0.00 0.00 8636.4 3861.2 340 0.0 12498 13.11 0.00 0.00 0.0 0.00 0,00 8590.4 3907.2 344 0.0 12498 13.10 0.00 0.00 0.0 0.00 0.00 8544.5 3953.1 348 0.0 12498 13.09 0.00 0.00 0.0 0.00 0.00 8498.5 3999.1 352 0.0 12498 13.08 0.00 0.00 0.0 0.00 0.00 8452.5 4045.1 356 0.0 12498 13.08 0.00 0.00 0.0 0.00 0.00 8406.E 4091.0 360 0.0 12498 13.07 0.00 0.00 0.0 0.00 0.00 8350.6 4137.0 364 0.0 12498 13.06 0.00 0.00 0.0 0.00 0.00 8314.6 4183.0 368 0.0 12498 13.05 0.00 0.00 0.0 0,00 0.00 8268.7 4228.9 372 0.0 12498 13.04 0.00 0.00 0.0 0.00 0.00 8222.7 4274.9 376 0.0 12498 13.03 0.00 0.00 0.0 0.00 0.00 8176.7 4320.9 380 0.0 12498 13.02 0.00 0.00 0,0 OM 0.00 8130.8 4366.8 384 0.0 12498 13.01 0.00 0.00 0.0 0.00 0.00 8084.8 4412.8 388 0.0 12498 13.01 0.00 0.00 0.0 0.00 0.00 8038.8 4458.8 392 0.0 12498 13.00 0.00 0.00 0.0 0.00 0.00 7992.9 4504.7 396 0.0 12498 12.99 0.00 0.00 0.0 0,00 0.00 7946.9 4550.7 400 0.0 12498 12.98 0.00 0.00 0.0 0.00 0.00 7900.9 4596.7 404 0.0 12498 12.97 0.00 0.00 0.0 0.00 0.00 7855.0 4642.6 408 0.0 12498 12.96 0.00 0.00 0.0 0.00 0.00 7809.0 4688.6 G.U095t2013b3026.Colony T,,e IcsU3026 Infiltration Routing 50yr24nr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 50-year 24hr Storm (No Infiltration) WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 50 YR 8.871N/HR Qa = 1.42 CFS Qa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P = 9 INCHES 50yr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S = 1.63 Depth (D) _ (P-0.2S)^2/(P+O.BS) D = 7.30 IN - 50yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = ](43.5)(D)(Area)] / Dp To= 15.96 MINUTES Storage Volume Req'o = (Qp-Qa)'Tp'1.39'60 = 10,567 cu. ft. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feel AFTER DEVELOPMENT WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 50 YR 8.87 IN/HR QP= 9.36 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq 9) (cu ft) (cu ft) (ft) (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3.306 3,306 1'0 8.1035 0 1.02 13.00 5020 4.437 7,743 2.0 8,9545 0.6931 1.95 14.00 6303 5,662 13.405 3.0 9.5033 1.0986 2.97 15.00 7644 6.974 20,378 4.0 9.9222 1.3863 4.09 Regression Output: ==>K5= 3240 In = 1.31 x Coefficient 8.08 G VOBS O13\13026-CoWy 1 ireY lu\I M261nllVation Routng 501a4hr no inLl 3/19/2014 Colony Tire 3026 MLV Slormwater Infiltration Basin Routing 50-year 24hr Storm (No Infiltration) CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.42 cis QP = 9.36 cfs ' Infiltration rate = Fh�.� X710 ini TIP = 16.0 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time = t: `57e0 days Ks = 3240 b= 1.31 Zo = 11.00 ft Normal water elev = 11.00 ft Peak Outflow = 0.00 cfs Box Weir Length = 0 It Peak Stage = 13.81 It Cw = 0.0 Maximum Storage = 12.498 cu ft Zcr = 0.00 it Control Holes: State Orifice: Dia = 0.00 in Dd = 0 in Inv = 0.00 It Cd = 0 Weir: L = 0 in Zi = 0.00 it Inv = 0.0 ft Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) ICU ft) 01) (cfs) (cfs) (cfs) (cfs) (cfs) (cu ft) (cf) 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11,00 0 0.00 0 0 0.00 0.0 0.0 8 4.7 330 11.17 0.00 0.00 0.0 0.00 0.00 330.5 0.0 12 8.0 1458 11.54 0.00 0.00 0.0 0.00 0.00 1457.9 0.0 16 9.4 3380 12.03 0.00 0.00 0.0 0.06 0.00 3379.5 0.0 20 8.0 5625 12.53 0.00 0.00 0.0 0,00 0.00 5025.1 0.0 24 5.7 7536 12.91 0.00 0.00 0.0 0.00 0.00 7536.2 0.0 28 4.2 8916 13.17 0.00 0.00 0.0 0.00 0.00 8915.9 0.0 32 3.0 9912 13.35 0.00 0.00 0.0 0,00 0.00 9911.9 0.0 36 2.2 10631 13.48 0.00 0.00 0.0 0.00 0.00 10630.9 0.0 40 1.6 11150 13.58 0.00 0.00 0.0 0.00 0.00 11150.0 0.0 44 1.1 11525 13,64 0.00 0.00 0.0 0.00 0.00 11524.7 0.0 48 0.8 11795 13.69 0.00 0.00 0.0 0.00 0.00 11795.3 0.0 52 0.6 11991 13.72 0.00 0.00 0.0 0.00 0.00 11990.6 0.0 56 0.4 12132 13.75 0.00 0,00 0.0 0.00 0.00 12131.6 0.0 60 0.3 12233 13.77 0.00 0.00 0.0 0.00 0.00 12233.4 0.0 64 0.2 12307 13.78 0.00 0.00 0.0 0.00 0.00 12306.8 0.0 68 0.2 12360 13.79 0.00 0.00 0.0 0.00 0.00 12359.9 0.0 72 0.1 12398 13.79 0.00 0.00 0.0 0.00 0.00 12398.2 0.0 76 0.1 12426 13.80 0,00 0,00 0.0 0.00 0.00 12425.8 1 80 0.1 12446 13.60 1 0,00 0.0 0,00 0.00 12445B 0.0 84 0.0 12460 13.81 1 0.00 0.0 0.00 0.00 12460.2 0.0 88 0.0 12471 13.81 0.00 0.00 0.0 0.00 0.00 12470.6 0.0 92 0.0 12478 13.81 0.00 0.00 0.0 0.00 0.00 12478.1 0.0 96 0.0 12484 13.81 0.00 0.00 0.0 0.00 0.00 12483.5 0.0 100 0.0 12487 13.81 0.00 0.00 0.0 0.00 0.00 12487.4 0.0 104 0.0 12490 13.81 0,00 0,00 0.0 0,00 0.00 12490.3 1 108 0.0 12492 13.81 0.00 0.00 0.0 0.00 0.00 12492.3 0.0 112 0.0 12494 13.81 0.00 1 0.0 0.00 0.00 12493.8 0.0 116 0.0 12495 13.81 0.00 0.00 0.0 0.00 0.00 12494.8 0.0 120 0.0 12496 13.81 0.00 0.00 0.0 0,00 0.00 12495.6 0.0 124 0.0 12496 13.81 0.00 0.00 0.0 0.00 0.00 12496.2 0.0 128 0.0 12497 13.81 0.00 0.00 0.0 0.00 0.00 12496.6 0.0 132 0.0 12497 13.81 0.00 0.00 0.0 0.00 0,00 12496.8 0.0 136 0.0 12497 13.81 0.00 0.00 0.0 0,00 0,00 12497.1 1 140 0.0 12497 13.81 0.00 0.00 0.0 0,00 0.00 12497.2 0.0 144 0.0 12497 13.81 0.00 0.00 0.0 0.00 0.00 12497.3 0.0 148 0.0 12497 13.81 0.00 0,00 0.0 0.00 0.00 12497.4 00 152 0.0 12497 13.81 000 0.00 0.0 0.00 0.00 12497.4 0.0 156 0.0 12497 13.81 1 0.00 0.0 0.00 0.00 12497.5 0.0 160 0.0 12498 13.81 0,00 0.00 0.0 0,00 0.00 12497.5 0.0 164 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.5 0.0 168 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0 0 172 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 176 0.0 12498 13.81 0,00 0.00 0.0 0.00 0.00 12497.6 0.0 180 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0,0 184 0.0 12498 13.81 1 0,00 0.0 000 0,00 12497.6 0.0 188 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 G UOBSV013\13026-Colony Ti troalcli 3026 Infiltration Routing 50ya4hr no infl 3/1912014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 50-year 24hr Storm (No Infiltration) 192 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.E 0.0 196 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 200 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 204 0.0 12498 13.81 0.00 0.00 0 0 0.00 0.00 12497.6 0.0 208 0.0 12498 13.81 0.00 0.00 1 0.00 0.00 12497.6 0.0 212 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 216 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 220 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 224 0.0 12498 13.81 0.00 0.00 1 0.00 0.00 12497.6 0.0 228 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 232 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 236 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 240 0.0 12498 13.81 0.00 0.00 0.0 0.00 1 12497.6 0.0 244 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 248 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 252 0.0 12498 13.81 0.00 0.00 1 0.00 0.00 12497.6 0.0 256 0.0 _ 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 260 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 264 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 268 0.0 12498 13.81 1 0.00 0.0 0.00 0.00 12497.6 0.0 272 0.0 12498 13.81 1 0.00 0.0 0.00 0.00 12497.6 0.0 276 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 280 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 284 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 288 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 292 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 1249L6 0.0 296 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 300 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 304 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 308 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.E 0.0 312 1 12498 13.61 0.00 0.00 0.0 0.00 0.00 12497.E 0.0 316 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 320 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 324 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 328 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 332 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 336 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 340 0.0 12498 13.81 0.00 0.00 0.0 1 0.00 12497.6 0.0 344 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 348 0.0 12498 13.81 0.00 0.00 0.0 1 0.00 12497.6 0.0 352 0.0 12496 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 356 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 360 0.0 12498 13.81 MID 0.00 0.0 0.00 0.00 12497.6 0.0 364 0.0 12498 13.81 0.00 0.00 0.0 1 0.00 12497.6 0.0 368 1 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 372 1 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 376 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 380 0.0 12498 13.81 0.00 0.00 0.0 1 0.00 12497.6 0.0 384 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 388 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 392 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 396 1 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 400 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 404 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 1 408 0.0 12498 13.81 0.00 0.00 0.0 0.00 0.00 12497.6 0.0 G:UOBS¢013\1302&Colony Tirekalcs\t 302E Infiltration Rowing 50,14hr no'mfil 3/1912014 Colony Tire 3026 MLV Stormwater Infiltration Basin Routing 100-year 24hr Storm WATERSHED DATA BEFORE DEVELOPMENT WATERSHEDAREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 100 VR 9.60 IN/HR Qa= 1.53 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P= 10 INCHES 100yr, 24hr PRECIPITATION CN= 86 S = (1000/CN)-10 S= 1.63 Depth (D) = (P.0.2S)^2/(Pt0.8S) D = 8.28 IN - 100yr, 24hr RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK TIP = [(43.5)(D)(Area)j / Qp TIP = 16.72 MINUTES Storage Volume Req'd = (Qp-Qa)'Tp'1.39'60 = 11.981 cu. ft. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feet AFTER DEVELOPMENT WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0,77 TIME OF CONCENTR 5.00 MIN INTENSITY 100 YR 9,60 IN/HR Op= 10.13 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE In S In Z Z est (sq ft) (cu ft) (cu ft) (ft) (ft) 11.00 2758 0 0 0 0 0 0 12.00 3854 3,306 3.306 1.0 8.1035 0 1.02 13.00 5020 4,437 7,743 2.0 8.9545 0,6931 1.95 14.00 6303 5.662 13.405 3.0 9.5033 1.0986 2.97 15.00 7644 6.974 20,378 4.0 9.9222 1.3863 4.09 Regression Output: Ks = 3240 b= 1.31 %Coefficient 8.08 G:VOBSQ013\1302GColony ❑reb lm\13026 lnGlvation Routing 100y04hr 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 100-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.53 cis QP= 10A3 cfs ' Infiltration rate = 2-'s«'ti":i3 in/6r Tp = 16.7 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time -; :2n:;:",0:72 days Ks = 3240 b= 1.31 Zo = 11.00 ft Normal water elev = 11.00 It Peak Outflow= 0.00 cfs Box Weir Length = 0 It Peak Stage = 13,93 ft Cw = 0.0 Maximum Storage = 13,201 cu It Zcr = 0.00 ft Control Holes: State Orifice: Dia = 0.00 in Dd= 0 in Inv= 0.00 ft Cd= 0 Weir L= 0 in Zi= 0.00 ft Inv= 0.0 ft Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFSlore Infiltrate (min) (cfs) (cu ft) (ft) (cfs) (cfs) (cfs) (cfs) (cfs) (cu if (cp 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11.00 0 0.00 0 0 0.00 0.0 46,0 8 4.7 327 11.13 0.00 0,00 0.0 0.00 0.00 235.5 91.9 12 8.3 1461 11 SO 0.00 0.00 0.0 0.00 0.00 1322.9 137.9 16 10.1 3444 12.00 0.00 0.00 0.0 0.00 0.00 32602 183.9 20 9.2 5864 12.53 0,00 0.00 0.0 0.00 0.00 5633.7 229.8 24 6.8 8070 12.96 0,00 0,00 0.0 0.00 0.00 7794.4 275.8 28 5.0 9702 13.26 0.00 0.00 0.0 0.00 0.00 9380.3 321.8 32 3.7 10898 13.47 0.00 0.00 0.0 0.00 0.00 10529.9 367.7 36 27 11774 13.61 0.00 0,00 0.0 0.00 0.00 11360.0 413.7 40 2.0 12416 13.72 0.00 0.00 00 0.00 0.00 11955.9 459.7 44 1.4 12886 13.79 0.00 0.00 0.0 0.00 0.00 12380.2 505.6 48 1.1 13230 13.84 0.00 0.00 0.0 0.00 0.00 12678.8 551.6 52 0.8 13483 13.88 0.00 0.00 0.0 0.00 0.00 12885.3 597.6 56 0.6 13668 13.90 0.00 0.00 0.0 0.00 0.00 13024.3 643.5 60 0.4 13803 13.92 0.00 0.00 0.0 0.00 0.00 13113.8 689.5 64 0.3 13903 13.93 0.00 0.00 0.0 0.00 0.00 13167.2 735.5 68 0.2 13975 1393 0.00 0.00 0.0 0.00 0.00 13194.0 781.4 72 0.2 14029 13.93 0.00 0.00 0.0 0.00 0.00 13201.3 627.4 76 0.1 14068 13.93 0.00 0.00 0.0 0.00 0.00 13194.4 873.4 80 0.1 14096 13.93 0.00 0.00 0.0 0.00 0,00 13177.0 919.3 84 0.1 14117 13.92 0.00 0.00 0.0 0.00 0.00 13152.0 965.3 88 0.0 14133 13.92 0.00 0.00 0.0 0.00 0.00 13121.4 1011.3 92 OD 14144 13,91 0,00 0.00 0.0 0.00 0,00 13086.7 1057.2 96 0.0 14152 13.91 0.00 0.00 0.0 0,00 0.00 13049.0 1103.2 100 0.0 14158 13.90 0.00 0.00 0.0 0.00 0,00 13009.1 1149.2 104 0.0 14163 13.89 0.00 0,00 0.0 0.00 0.00 12967.5 1195.1 108 0.0 14166 13S8 0.00 0.00 0.0 0,00 0.00 12924.8 1241A 112 0.0 14168 13BB 0.00 0.00 0.0 0.00 0.00 12881.2 1287.1 116 0.0 14170 13.87 0.00 0.00 0.0 0.00 0.00 12837.0 1333.0 120 0.0 14171 13A6 0.00 0.00 0.0 0.00 0.00 12792.3 1379.0 124 0.0 14172 13S5 0.00 0,00 0.0 0.00 0,00 12747.3 1425.0 128 0.0 14173 13,85 0.00 0.00 0.0 0.00 0.00 12702.0 1470.9 132 0.0 14173 13.84 0.00 0.00 0.0 0.00 0.00 12656.5 1516.9 136 0.0 14174 13.83 0.00 0.00 0.0 0.00 0,00 12610.9 1562.9 140 0.0 14174 13-82 0.00 0,00 0.0 0.00 0.00 12565.2 1608.8 144 0.0 14174 13.82 0.00 0.00 0.0 0.00 0,00 12519.5 1654.8 148 0.0 14174 13S1 0.00 0.00 0.0 0.00 0.00 12473.6 1700.8 152 0.0 14175 13.80 0.00 0,00 0.0 0,00 0.00 12427.8 1746.7 156 0.0 14175 1339 0.00 0,00 0.0 0.00 0.00 12381.9 1792.7 160 0.0 14175 1378 0.00 0,00 0.0 0.00 0.00 12336.0 1838.7 164 0.0 14175 13,78 0.00 0.00 0.0 0.00 0.00 12290.0 1884.E 168 0.0 14175 13.77 0.00 0.00 0.0 0.00 0.00 12244.1 1930.6 172 0.0 14175 13.76 0.00 0.00 0.0 0.00 0.00 12198.2 1976.6 176 0.0 14175 13,75 0.00 0.00 0.0 0.00 0.00 12152.2 2022S 180 0.0 14175 13.74 0.00 0,00 0.0 0.00 0,00 12106.3 2068.5 184 0.0 14175 1334 0,00 0.00 0.0 0.00 0.00 12060.3 2114S 188 0.0 14175 13.73 0,00 0.00 0.0 0.00 0.00 12014.3 2160A G,VOBS2013AlW2 olony Tim ata%130261nfilvawn Routing 100yr24hr 3/1912014 Colony Tire 13025 MLV Stormwaler Infiltration Basin Routing 100-year 24hr Storm 192 0.0 14175 1372 0.00 0.00 0.0 0,00 0.00 11968.4 2206.4 196 0.0 14175 13.71 0.00 0.00 0.0 0,00 0.00 119224 2252.4 200 0.0 14175 13.70 0.00 0.00 0.0 0.00 0.00 11876.5 2298.3 204 0.0 14175 13.70 0.00 0.00 0.0 0.00 0.00 11 B30.5 2344.3 208 0.0 14175 13.69 0.00 0.00 0.0 0.00 0.00 11784.5 2390.3 212 0.0 14175 13,68 0.00 0,00 0.0 0.00 0.00 11738.6 2436.2 216 0.0 14175 13.67 0.00 0.00 0.0 0.00 O.00 11692.6 2482.2 220 0.0 14175 13.66 0.00 O.00 0.0 0.00 0.00 11646.6 2528.2 224 0.0 14175 13.66 0.00 0.00 0.0 0.00 0.00 11600.7 2574.1 228 0.0 14175 13.65 0.00 0.00 0.0 0.00 0.00 11554.7 2620.1 232 0.0 14175 13.64 0.00 0.00 0.0 0.00 0.00 11508.7 2666.1 236 0.0 14175 13.63 0.00 0.00 0.0 0.00 0.00 11462.8 2712.0 240 0.0 14175 13.62 0.00 0.00 0.0 0.00 0.00 11416.8 2758.0 244 0.0 14175 13,62 0.00 0.00 0.0 0.00 0.00 11370.8 2804.0 248 0.0 14175 13.61 0.00 0.00 0.0 0.00 0.00 11324.9 2849.9 252 0.0 14175 13.60 0.00 0.00 0.0 O.00 0.00 11278.9 2895.9 256 0.0 14175 13.59 0.00 0.00 0.0 0.00 0.00 11232.9 2941.9 260 0.0 14175 13.58 0.00 O.00 0.0 0.00 0.00 11187.0 2987.8 264 0.0 14175 13.57 0.00 0.00 0.0 0.00 0.00 11141.0 3033.8 268 0.0 14175 13.57 0.00 0.00 0.0 0.00 0.00 11095.0 3079.8 272 0.0 14175 13.56 0.00 0.00 0.0 0.00 0.00 11049.1 3125.7 276 0.0 14175 13.55 0.00 0.00 0.0 0.00 0.00 11003.1 3171.7 280 0.0 14175 13.54 0.00 0.00 0.0 0.00 0.00 10957.1 3217.7 284 0.0 14175 13.53 0.00 0.00 0.0 0.00 0.00 10911.2 3263.6 288 0.0 14175 13.53 0.00 O.00 0.0 0.00 0.00 10865.2 3309.6 292 0.0 14175 13.52 0.00 0.00 0.0 0.00 0.00 10819.2 3355.6 296 0.0 14175 13.51 0,00 0.00 0.0 0.00 0.00 10773.3 3401.5 300 0.0 14175 13.50 0.00 0.00 0.0 0.00 0.00 10727.3 3447.5 304 0.0 14175 13.49 0.00 0.00 0.0 0.00 0.00 10681.3 3493.5 308 0.0 14175 13.48 0.00 0.00 0.0 0.00 0.00 10635.4 3539.4 312 0.0 14175 13.48 0.00 0.00 0.0 0.00 0.00 10589.4 3585.4 316 0.0 14175 13.47 0.00 0.00 0.0 0.00 0.00 10543.4 3631.4 320 0.0 14175 13.46 0.00 O.00 0.0 0.00 0.00 10497.5 3677.3 324 0.0 14175 13.45 0.00 0,00 0.0 0.00 0.00 10451.5 3723.3 328 0.0 14175 13.44 0.00 0.00 0.0 0.00 0.00 10405.5 3769.3 332 0.0 14175 13.44 0.00 0.00 0.0 0.00 0.00 10359.6 3815.2 336 0.0 14175 13.43 0.00 0.00 0.0 0.00 0.00 10313.6 3861.2 340 0.0 14175 13.42 0.00 0.00 0.0 0,00 0.00 10267.6 3907.2 344 0.0 14176 13.41 0.00 0.00 0.0 0.00 0.00 10221.7 3953.1 348 0.0 14175 13.40 0.00 0.00 0.0 0.00 0.00 10175.7 3999.1 352 0.0 14175 13.39 0.00 0.00 0.0 0.00 OM 10129.7 4045.1 356 0.0 14175 13.39 0.00 0.00 0.0 0.00 0.00 10083.8 4091.0 360 0.0 14175 13.38 0.00 0.00 0.0 0.00 0.00 10037.8 4137.0 364 0.0 14175 13,37 0.00 0.00 0.0 0.00 0.00 9991.8 4183.0 368 0.0 14175 13.36 0.00 0.00 0.0 0.00 0.00 9945.9 4228.9 372 0.0 14176 13.35 0.00 0.00 0.0 0.00 0.00 9899.9 4274.9 376 0,0 14175 13.34 0.00 0.00 0.0 0.00 0.00 9853.9 4320.9 380 0.0 14175 13.34 0.00 0,00 0.0 0.00 0.00 9808.0 4366.8 384 0.0 14175 13.33 0.00 O.00 0.0 0.00 0.00 9762.0 4412.8 388 0.0 14175 13.32 0.00 0.00 0.0 0.00 0.00 9716.0 4458.8 392 0.0 14175 13.31 0.00 0.00 0.0 0.00 0.00 9670.1 4504.7 396 0.0 14175 13.30 0.00 0.00 0.0 0.00 0.00 9624.1 4550.7 400 0.0 14175 13.29 0.00 0.00 0.0 0.00 0.00 9578.1 4596.7 404 0.0 14175 13.28 0.00 0.00 0.0 0.00 0.00 9532.2 4642.6 408 0.0 14175 13.28 0.00 0.00 0.0 0.00 0.00 9496.2 4688.6 G 1IC6512013\13026-COlony Ti,,a aICM13026 Infiltration Rowng 100224hr 3/19/2014 MLV Colony Tire Stormwater Infiltration Basin Routing 100-year 24hr Storm 13026 WATERSHED DATA WATERSHED AREA 0.47 ACRES HYDRAULIC LENGTH 200 FT CHANGE IN HEIGHT 7 FT RUNOFF COEF.'C' 0.34 TIME OF CONCENTR 5.00 MIN INTENSITY 100 YR 9.601N/HR Qa= 1.53 CFS Oa = PRE -DEVELOPED PEAK DISCHARGE COMPUTE DEPTH OF RUNOFF P= 10 INCHES 100yr, 24hr PRECIPITATION CN= 86 S = (1000/CN).10 S= 1.63 Depth (D) = (P.0.2S)"21(P+0.8S) D= 8,28 IN- 100yr, 241fir RUNOFF DEPTH SET VOLUME AND COMPUTE TIME TO PEAK Tp = [(43.5)(D)(Area)l / Op Tp= 16.72 MINUTES Storage Volume Req'd = (Op-Qa)'Tp'1.39'60 11,981 cu. ft. CALCULATE Ks AND b SET NORMAL ELEVATION AT = 11.00 feet WATERSHED AREA 1.37 ACRES HYDRAULIC LENGTH 240 FT CHANGE IN HEIGHT 10 FT RUNOFF COEF.'C' 0.77 TIME OF CONCENTR 5.00 MIN INTENSITY 100 YR 9.601WHR Qp= 10.13 CFS Op = POST -DEVELOPED PEAK DISCHARGE S Z CONTOUR INCR ACCUM CONTOUR AREA VOL VOL STAGE InS InZ Zest (sq ft) (cu ft) (cu ft) (ft) (ft) 11,00 2758 0 0 0 0 0 0 12.00 3854 3,306 3.306 1.0 8.1035 0 1.02 13.00 5020 4.437 7,743 2.0 8.9545 0.6931 1.95 14.00 6303 5,662 13.405 3.0 9,5033 1,0986 2.97 15,00 7644 6,974 20,378 4.0 9.9222 1.3863 4.09 Regression Output: Ks = 3240 b= 1.31 X Coefficient 8.08 0 G:UOBSU013\13026-Cobny TireYaksU30261nfilvabon Routing 10DW4hr no infil 3/19/2014 Colony Tire 13026 MLV Stormwater Infiltration Basin Routing 100-year 24hr Storm CHAINSAW METHOD FOR RISER BARREL ROUTING STORM DATA Oa = 1.53 cis Op = 10.13 cis ' Infiftration rate = ,.y: r'i.°:+.0 in1hr Tp = 16.7 min (Per Soils Report) dT= 4 min BASIN DATA Basin Drawdown Time = TT77 days Ks = 3240 b = 1.31 Zo = 11.00 It Normal water elev = 11.00 It Peak Outflow= 0.00 cis Box Weir Length = 0 fit Peak Stage = 14.10 It Cw = 0.0 Maximum Storage = 14,175 cu it Zcr = 0.00 It Control Holes: State Orifice: Dia = 0.00 in Dd= 0 in Inv= 0.00 ft Cd = 0 Weir. L = 0 in Zi = 0.00 it Inv = 0.0 it Time Inflow Storage Stage Outflow W Riser Barrel Orifice Weir IFStore Infiltrate (min) (cfs) (cu It) (fi) (cfs) (cfs) (cfs) (cfs) (cfs) (cu fl) (cf) 0 0.0 0 11.00 0 0 0 0 0.00 0.0 0.0 4 1.4 0 11.00 0 0.00 0 0 0.00 0.0 0.0 8 4.7 327 11.17 0.00 0.00 0.0 0.00 0.00 327.4 0.0 12 8.3 1461 11.54 0.00 0.00 0.0 0.00 0.00 1460.8 0.0 16 10.1 3444 12.05 0.00 0.00 0.0 0.00 0.00 3444.1 0.0 20 9.2 5864 12.57 0.00 0.00 0.0 0.00 0.00 5863.5 0.0 24 6.8 8070 13.01 0.00 0.00 0.0 0.00 0.00 8070.2 0.0 28 5.0 9702 13.32 0.00 0.00 0.0 0.00 0.00 9702.0 0.0 32 3.7 10898 13.53 0.00 0.00 0.0 0.00 0.00 10897.7 0.0 36 2.7 11774 13.69 0,00 0.00 0.0 0.00 0.00 11773.7 0.0 40 2.0 12416 13.80 0.00 0.00 0.0 0.00 0.00 12415.5 0.0 44 1.4 12886 13.88 0.00 0.00 0.0 0.00 0.00 12885.8 0.0 48 1.1 13230 13.94 0.00 0,00 0.0 0.00 0.00 13230.4 0.0 52 0.8 13483 13.98 0.00 0.00 0.0 0.00 0.00 13482.8 0.0 56 0.6 13668 14.01 0.00 0.00 0.0 0.00 0.00 13667.8 0.0 60 0.4 13803 14.03 0.00 0.00 0.0 0.00 0.00 13803.3 0.0 64 0.3 13903 14.05 0.00 0.00 0.0 0.00 0.00 13902.E 0.0 68 0.2 13975 14.06 0.00 0.00 0.0 0.00 0.00 13975.4 0.0 72 0.2 14029 14.07 0.00 0.00 0.0 0.00 0.00 14028.7 0.0 76 0.1 14068 14.08 0.00 0.00 0.0 0.00 0.00 14067.7 0.0 80 0.1 14096 14.08 0.00 0.00 0.0 0.00 0,00 14096.4 0.0 84 0.1 14117 14.09 0.00 0.00 0.0 0.00 0.00 14117.3 0.0 88 0.0 14133 14.09 0.00 0.00 0.0 0.00 0.00 14132.7 0.0 92 0.0 14144 14.09 0.00 0.00 0.0 0.00 0.00 14143.9 0.0 96 0,0 14152 14.09 0.00 0.00 0.0 0.00 0.00 14152.2 0.0 100 0.0 14158 14.09 0,00 0,00 0.0 0.00 0.00 14158.2 0.0 104 0.0 14163 14.09 0.00 0,00 0.0 0.00 0.00 14162.7 0.0 108 0.0 14166 14.09 0.00 0.00 0.0 0.00 0.00 14165.9 0.0 112 0.0 14168 14.10 0,00 0.00 0.0 0.00 0.00 14168.3 D.0 115 0.0 14170 14.10 0.00 6.0E 0.0 0.00 0.00 14170.0 0.0 120 0.0 14171 14.10 0.00 0,00 0.0 0.00 0.00 14171.3 0.0 124 0.0 14172 14.10 0,00 0.00 0.0 0.00 0.00 14172.2 0.0 128 0.0 14173 14.10 0.00 0.00 0.0 0.00 0.00 14172.9 0.0 132 0.0 14173 14.10 0.00 0.00 0.0 0.00 0.00 14173.4 0.0 136 0.0 14174 14.10 0,00 0.00 0.0 0.00 0.00 14173.8 0.0 140 0.0 14174 14.10 0,00 0,00 0.0 0.00 0.00 14174.1 0.0 144 0.0 14174 14.10 0.00 0.00 0.0 0.00 0.00 14174.3 0.0 148 0.0 14174 14.10 0.00 0.00 0.0 0.00 0.00 141744 0.0 152 0.0 14175 14.10 0,00 0,00 0.0 0.00 0.00 14174.5 0.0 156 0.0 14175 14.10 0.00 0.00 0.0 0,00 0.00 14174.E 0.0 160 0.0 14175 14.10 0.00 0,00 0.0 0.00 0.00 14174.6 0.0 164 0.0 14175 - 14.10 0.00 0.00 0.0 0.00 0.00 14174.7 0.0 168 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.7 0.0 172 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.7 0.0 176 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.7 0.0 180 0.0 14175 14.10 0,00 0.00 0.0 0.00 0.00 14174.8 0.0 184 0.0 14175 14.10 0,00 0.00 0,0 0.00 0.00 14174.8 0.0 188 0.0 14175 -14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 GVOBSr2013\13026-Cobny Tiretra %IW261nfIVaGon Rouung 10pyQ4hrnoinfl 311912014 Colony Tire MLV Stormwater Infiltration Basin Routing 3026 100-year 24hr Storm 192 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 196 0.0 14175 14.10 0.00 0.00 O.o 0.00 0.00 14174.8 0.0 200 0'0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 204 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 208 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 212 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 216 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 220 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 224 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 228 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 232 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 236 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 240 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 244 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 248 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 252 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 256 0.0 14175 14.10 0.00 Goo 0.0 0.00 0.00 14174.8 0.0 260 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 264 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 268 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 272 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 276 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 280 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 284 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 288 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 292 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 296 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 300 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 304 0.0 14175 14.10 0.00 0.00 0'0 0.00 0.00 14174.8 0.0 308 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 312 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 316 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 320 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 324 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 328 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 332 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 336 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14474.8 0.0 340 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 344 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 348 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 352 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 O.o 356 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 360 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 364 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 368 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 372 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 376 0.0 14175 14.10 0.00 0,00 0.0 0.00 0.00 14174.8 0.0 380 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 384 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 388 0.0 14175 14.10 0.00 0.00 O.O 0.00 0.00 14174.8 0.0 392 0.0 14175 14.10 0.00 0.00 O.o 0.00 0.00 14174.8 0.0 396 0'0 14175 14.10 0.00 0.00 0'0 0.00 0.00 14174.8 0.0 400 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 404 0.0 14175 14.10 0.00 0.00 0'0 0.00 0.00 14174.8 0.0 408 0.0 14175 14.10 0.00 0.00 0.0 0.00 0.00 14174.8 0.0 G'.UOBS@01313026 Color, Trekaloe113026 1nfilVetlon Routing 100y14hr no Infil �pFFM,r. a LIMITED LIABILITY COMPANY ANNUAL REPORT NAME OF LIMITED LIABILITY COMPANY: BCC of Edenton. LLC REPORT FOR THE YEAR: 2014 SECRETARY OF STATE L.L.C. Ill NUMBER: 1284383 NATURE OF BUSINESS:Rea[ Estate REGISTERED AGEN : BERGERON, ANDREWO REGISTERED OFFICE MAILING ADDRESS: P 0. Box 827 Edenton, NC 27932-0827 E-Filed Annual Report 10103134 Do not data enter manually. STATE OF INCORPORATION: NC REGISTERED OFFICE STREET ADDRESS: 1415 N Broad Street Edenton, NC 27932-9613 Chowan County PRINCIPAL OFFICETELEPHONE NUMBER: 252-482-5521 PRINCIPAL OFFICE, MAILING ADDRESS: P. 0. Box 827 Edenton, NC 27932-0827 PRINCIPAL OFFICE STREET ADDRESS: 14/5 N. Broad Street Edenton, NC 27932-9613 Company Officials: Natne: Andrew Onter Bergeron Name: Charles Scott Creighton Natne: Charles Alfred Creighton Tide: Manager Title: ,Manager "fide: Manager Address: Address: Address: 203 Blount Street 106 Corbin Court 115 IN King Street Edenton, NC 27932 Edenton, NC 27932 Edenton, NC 27932 CERTIFICATION OF ANNUAL REPORT MUST BE COMPLETED BY ALL LIMITED LIABILITY COMPANIES Andrew Omer Bergeron FORM MUST BE SIGNED I3Y A MANAGEWMEMBER Andrew Outer Bergeron 3/4/2014 DATE Manager TYPE OR PRINT NAME TYPE OR PRINT TITLE ANNUAL REPORT FEE: F-Paid MAIL TO: Secretary of State • Corporations Division • Post Office Box 29525 • Raleigh, NC 27626-0525 Account North Carolina Elaine F. Marshall DEf ARTMENT OFTIdE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NC 27626-0622 (919)607-2000 Date: 4/17/2014 here to: Document Filings I File an Annual Report I J Print a Pre -populated Annual Report Fillable PDF Form I Amend A Previous Annual Report I rporation Names Name Name Type NC BCC OF EDENTON, LLC LEGAL Limited Liability Company Information SOS I D: 1284383 Status: Current-Acti\e Effective Date: 10/24/2012 Citizenship: DOMESTIC Duration: PERPETUAL Annual Report Status: CURRENT Registered Agent Agent Name: Office Address: Mailing Address: 'rincipal Office Office Address: Mailing Address: mpany Officials Title: Name: Business Address: Title: Name: Business Address: BERGERON,ANDREW O 1415 N. BROAD STREET EDENTON NC 27932-9613 P. O. BOX827 EDENTON NC 27932-0827 1415 N. BROAD STREET EDENTON NC 27932-9613 P. O. BOX 827 EDENTON NC 27932-0827 MANAGER ANDREW OMERBERGERON 203 BLOUNT STREET EDENTON NC 27932 MANAGER CHARLES SCOTT CREIGHTON 106 CORBIN COURT EDENTON NC 27932