Loading...
HomeMy WebLinkAboutSW8131207_APPROVED PLANS_20140516 (2)STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 1312 01 DOC TYPE ❑ CURRENT PERMIT ® APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2o\LA 051 b YYYYMMDD i DEVELOPER: DR HORTON, INC 4073 BELLE TERRE BLVD. MYRTLE BEACH, SC 29579 PHASE 4 BRUNSWICK COUNTY, NC DESIGN DOCUMENTS ENGINEER (CIVIL)/LAND SURVEYOR: PARAMOUNTE ENGINEERING, INC. 5911 OLEANDER DRIVE, SUITE 201 WILMINGTON, NORTH CAROLINA 28403 ATTN: TIM CLINKSCALES, P.E., P.L.S. (910) 791-6707 NOTICE REQUIRED ALL EXISTING UNDERGROUND UTIUTIES SHALL BE PHYSICALLY LOCATED PRIOR TO THE BEGINNING OF ANY CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. CONTRACTORS SHALL NOTIFY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF PROPOSED EXCAVATION AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN TEN WORKING DAYS PRIOR TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. BRUNSWICK COUNTY ATTN: LESUE BELL PH: 910-253-2657 PROGRESS ENERGY PH: 1-800-M-4949 PIEDMONT NATURAL GAS PH: 910-799-7185 EMERGENCY DIAL 911 POLICE - FIRE - RESCUE CONTACT "CAROLINA ONE CALL" AT 1-800-632-4949 CONTACT THESE UTILITIES BELL SOUTH PH: 1-800-632-4949 TIME WARNER CABLE PH: 910-763-4638 NOV MB R 2013 FOR: D.R. HORTON, INC 4073 BELLE TERRE BLVD, MYRTLE BEACH, SC 29579 VICINITY MAP (NOT TO SCALE) 133 z SHEETINDEX SHEET NUMBER SHEET TITLE C-0.0 COVER SHEET C-1.0 GENERAL NOTES C-2.0 SITE PLAN C-3.0 — C-3.1 GRADING, DRAINAGE, 81 EC C-5.0 — C-5.3 DETAILS pARAMouNTE 5911 Oleander Drive, Suite 201 Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6707 (F) PROJECT # 12293.PE �FaC"�1\/E oEC 6 9 2I1r3 �? aY: 5w���Pa NC ACCESSIBILITY NOTES: GENERAL NOTES: 1. SPECIAL ATTENTION SHALL BE GIVEN TO COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ANSI A117.1. AND APPLICABLE LOCAL LAWS & REGULATIONS. 2. IT IS ESSENTIAL THAT CONTRACTORS ARE AWARE OF THE SITE ACCESSIBILITY REQUIREMENTS. PARAMOUNTE ENGINEERING HAS DEVELOPED THESE NOTES AND DETAILS TO ASSURE THAT CONTRACTORS ARE AWARE OF THE REQUIREMENTS AT THE POINT IN TIME WHEN THEYARE BIDDING THE PROJECT. IN ADDITION, PARAMOUNTE ENGINEERING HAS MADE A POINT IN THESE NOTES AND DETAILS, AS WELL AS IN OUR DRAWINGS, TO PROVIDE SLOPES / GRADES AND DIMENSIONS THAT COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODEIANSI A117.1 AND APPLICABLE LOCAL LAWS & REGULATIONS. IF THESE SLOPES / GRADES AND DIMENSIONS ARE NOT ACHIEVABLE, THE CONTRACTOR IS REQUIRED TO CONTACT THE OWNER IMMEDIATELY AND BEFORE MOVING FORWARD WITH THE WORK 3. THE CONTRACTOR SHALL NOTIFY PARAMOUNTE ENGINEERING IMMEDIATELY OF ANY CONFLICT BETWEEN THESE NOTES AND DETAILS AND OTHER PROJECT DRAWINGS, WHETHER BY PARAMOUNTE ENGINEERING OR OTHERS. THE CONTRACTOR SHALL NOT PROCEED WITH THE WORK FOR WHICH THE ALLEGED CONFLICT HAS BEEN DISCOVERED UNTIL SUCH ALLEGED CONFLICT HAS BEEN RESOLVED. NO CLAIM SHALL BE MADE BY THE CONTRACTOR FOR DELAY OR DAMAGES AS A RESULT OF RESOLUTION OF ANY SUCH CONFUCT(S). 4. THESE ACCESSIBILITY NOTES AND DETAILS ARE INTENDED TO DEPICT SLOPE AND DIMENSIONAL REQUIREMENTS ONLY. REFER TO SIDEWALK. CURBING, AND PAVEMENT DETAILS FOR ADDITIONAL INFORMATION. ACCESSIBLE ROUTE NOTES: 1. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS OR SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. 2. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. 3. WALKING SURFACES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL HAVE A MAXIMUM RUNNING SLOPE OF 5.0% AND A MAXIMUM CROSS SLOPE OF 2.0%. 4. ANY WALKING SURFACE THAT IS PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 5.0% IS A RAMP AND SHALL COMPLY WITH THE GUIDELINES FOR RAMPS OR CURB RAMPS. 5. TRANSITIONS BETWEEN RAMPS, WALKS, LANDINGS, GUTTERS OR STREETS SHALL BE FLUSHAND FREE OF ABRUPT VERTICAL CHANGES (1/41NCH MAXIMUM VERTICAL CHANGE IN LEVEL PERMITTED) 6. FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. 7. THE MINIMUM CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES SHALL BE FOURTY-EIGHT (48) INCHES MINIMUM MEASURED BETWEEN HANDRAILS WHERE HANDRAILS ARE PROVIDED (NC BUILDING CODE 1104.1 & 11042). S. WHERE AN ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN OBJECT THAT IS LESS THAN FORTY-EIGHT (48) INCHES IN WIDTH, CLEAR WIDTH SHALL BE FORTY-TWO (42) INCHES MINIMUM APPROACHING THE TURN, FORTY-EIGHT (48) INCHES MINIMUM DURING THE TURN, AND FORTY-TWO (42) INCHES MINIMUM LEAVING THE TURN. THE CLEAR WIDTH APPROACHING AND LEAVING THE TURN MAY BE THIRTY-SIX (36) INCHES MINIMUM WHEN THE CLEAR WIDTH AT THE TURN IS SIXTY (60) INCHES MINIMUM..' SEE NOTE 7 ABOVE FOR NC CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES' A WIDTH LESS THAN SIXTY 60 INCHES SHALLPROVIDE 9. AN ACCESSIBLE ROUTE WITH CLEAR ( ) PASSING SPACES AT INTERVALS OF TWO HUNDRED (200) FEET MAXIMUM. PASSING SPACES SHALL BE EITHER A SIXTY (60) INCH MINIMUM BY SIXTY (60) INCH MINIMUM SPACE; OR AN INTERSECTION OF TWO (2) WALKING SURFACES THAT PROVIDE A COMPLIANT TSHAPED TURNING SPACE, PROVIDED THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND FORTY-EIGHT (48) INCHES MINIMUM BEYOND THE INTERSECTION. 10. DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 11. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE BUILDING ENTRANCE SHALL BE PROVIDED AT INACCESSIBLE BUILDING ENTRANCES. 12. WHERE POSSIBLE, DRAINAGE INLETS SHALL NOT BE LOCATED ON AN ACCESSIBLE ROUTE. IN THE EVENT THAT A DRAINAGE INLET MUST BE LOCATED ON AN ACCESSIBLE ROUTE, THE GRATE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), A117,1, THE NC BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS RAMP NOTES: 1. ANY PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 50/6 SHALL BE CONSIDERED A RAMP. 2. THE MAXIMUM RUNNING SLOPE FOR A RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 3. THE CLEAR WIDTH OF AN EXTERIOR RAMP RUN SHALL BE FORTY EIGHT INCHES (NC BUILDING CODE 1104.1). WHERE HANDRAILS ARE PROVIDED ON THE RAMP RUN, THE CLEAR WIDTH SHALL BE MEASURED BETWEEN THE HANDRAILS. 4. THE RISE FOR ANY RAMP RUN SHALL BE THIRTY (30) INCHES MAXIMUM. S. LANDINGS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF RAMPS. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2.0% IN ANY DIRECTION. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. THE LANDING CLEAR LENGTH SHALL BE SIXTY (60) INCHES LONG MINIMUM. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING OF SIXTY (60) INCHES BY SIXTY (60) INCHES MINIMUM. 6. RAMP RUNS WITH A RISE GREATER THAN SIX (6) INCHES SHALL HAVE HANDRAILS ON BOTH SIDES COMPLYING WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODE/ANSI A117.1. AND APPLICABLE LOCAL LAWS & REGULATIONS. 7 .FLOOR SURFACES OF RAMPS AND LANDINGS SHALL BE STABLE, FIRM AND SLIP RESISTANT. 8. EDGE PROTECTION COMPLYING WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODEIANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND ON EACH SIDE OF RAMP LANDINGS. 9. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY THE AMERICANS WITH DISABIUTIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODEIANSI A117.1 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA WHERE DOORS THAT ARE SUBJECT TO LOCKING ARE ADJACENT TO A RAMP LANDING, LANDINGS SHALL BE SIZED TO PROVIDE A COMPLIANT TURNING SPACE. CURB RAMP NOTES: 1. THE MAXIMUM RUNNING SLOPE OF A CURB RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 2. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP SHALL NOT BE STEEPER THAN 5%. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS AND STREETS SHALL BE AT THE SAME LEVEL 3. THE CLEAR WIDTH OF A CURB RAMP SHALL BE 36 INCHES (36) MINIMUM, EXCLUSIVE OF FLARED SIDES, IF PROVIDED. "NOTE NC BUILDING CODE REQUIRES EXTERIOR ACCESSIBLE ROUTES TO BE 48 INCHES MINIMUM WIDE (1104.1 & 1104.2).' 4. LANDINGS SHALL BE PROVIDED AT THE TOP OF CURB RAMPS. THE CLEAR LENGTH OF THE LANDING SHALL BE THIRTY-SIX (36) INCHES MINIMUM. THE CLEAR WIDTH OF THE LANDING SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES, LEADING TO THE LANDING. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2% IN ANY DIRECTION. 5. IF A CURB RAMP IS LOCATED WHERE PEDESTRIANS MUST WALK ACROSS THE RAMP, OR WHERE IT IS NOT PROTECTED BY HANDRAILS OR GUARDRAILS, IT SHALL HAVE FLARED SIDES. 6. WHERE PROVIDED, CURB RAMP FLARES SHALL NOT EXCEED 10%. 7. CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES OR PARKING ACCESS AISLES. CURBS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. 8. CURB RAMPS SHALL BE LOCATED OR PROTECTED TO PREVENT THEIR OBSTRUCTION BY PARKED VEHICLES. 9. IT IS RECOMMENDED TO PROVIDE CURB RAMPS WITH A TWENTY-FOUR (24) INCH DEEP DETECTABLE WARNING COMPLYING WITH 406.12 A117.1. EXTENDING THE FULL WIDTH OF THE RAMP. REFERTO DETECTABLE WARNING DETAILS AND NOTES FOR PLACEMENT, ORIENTATION AND NOTES. THE NC BUILDING CODE DOES NOT CURRENTLY REQUIRE DETECTABLE WARNINGS AT CURB RAMPS, NOR DO THE 2010 ADA STANDARDS - HOWEVER US DOT ADA REGULATIONS DO REQUIRE THESE. 10. FLOOR SURFACES OF CURB RAMPS SHALL BE DEEP GROOVED, % INCH WIDE BY %. INCH DEEP, ONE (1) INCH CENTERS TRANSVERSE TO THE RAMP. 11. WHERE PROVIDED, STOP LINES SHALL BE LOCATED IN ADVANCE OF CURB RAMP. 12. WHERE PROVIDED, PEDESTRIAN ACTIVATED SIGNALS SHALL BE LOCATED ADJACENT TO THE SIDEWALK AND NOT ON THE SIDEWALK 13. WHERE PROVIDED, DRAINAGE INLETS SHALL BE LOCATED UPSTREAM OF CURB RAMPS AND NOT IN THE RAMP AREA. 14. CURB RAMP TYPE AND LOCATION ARE PER PLAN. NC ACCESSIBILITY NOTES (CONT.): PARKING SPACE NOTES: 1. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTES OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE BUILDING ENTRANCE. 2. ACCESSIBLE PARKING SPACES SHALL BE AT LEAST NINEWSIX (96) INCHES WIDE. ACCESS AISLES SHALL BE 60 INCHES WIDE. ONE OF SIX ACCESSIBLE SPACES SHOULD PROVIDE A VAN ACCESSIBLE AISLE. THE AISLE SHOULD BE 96 INCHES WIDE (OR ACCESSIBLE SPACE IS 11 FEET AND ACCESS AISLE IS FIVE FEET). WHERE PARKING SPACES AND ACCESS AISLES ARE MARKED WITH LINES, THE WIDTH MEASUREMENTS SHALL BE MADE FROM CENTERLINE OF THE MARKINGS. WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLES, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE. 3. PARKING ACCESS AISLES SHALL BE PART OF AN ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY ENTRANCE AND SHALL COMPLY WITH PROVISIONS FORACCESSIBLE ROUTES. MARKED CROSSINGS SHALL BE PROVIDED WHERE THE ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES. WHERE POSSIBLE, IT IS PREFERABLE THAT THE ACCESSIBLE ROUTE NOT PASS BEHIND PARKED VEHICLES. 4. TWO (2) ACCESSIBLE PARKING SPACES MAY SHARE A COMMON ACCESS AISLE. S. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACE THEY SERVE. 6. ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. 7. ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPTFOR ANGLED VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. 8. FLOOR SURFACES OF PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE, FIRM AND SUP RESISTANT. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. 9. PARKING SPACES AND ACCESS AISLES SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. 10. PARKED VEHICLE OVERHANGS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE ROUTE. 11. PARKING SPACES FOR VANS AND ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF NINETY-EIGHT (98) INCHES MINIMUM. SIGNS SHALL BE PROVIDED AT ENTRANCES TO PARKING FACILITIES INFORMING DRIVERS OF CLEARANCES AND THE LOCATION OF VAN ACCESSIBLE PARKING SPACES. 12. EACH ACCESSIBLE PARKING SPACE SHALL BE PROVIDED WITH SIGNAGE DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL BE INSTALLED AT A MINIMUM CLEAR HEIGHT OF SIXTY (60) INCHES ABOVE GRADE AND SHALL NOT INTERFERE WITH AN ACCESSIBLE ROUTE FROM AN ACCESS AISLE. SIGNS LOCATED WHERE THEY MAY BE HIT BY VEHICLES BEING PARKED SHALL BE INSTALLED WITH BOLLARD PROTECTION. 13. SIGNAGE AT ACCESSIBLE PARKING SPACES REQUIRED BY THE NC BUILDING CODE SECTION 1106ASHALL COMPLY WITH THE REQUIREMENTS OF NORTH CAROLINA GENERAL STATUTE 20.37.6 AND 136-30 AND THE NCDOT UNIFORM MANUAL ON TRAFFIC CONTROL DEVICES. A SEPARATE SIGN IS REQUIRED FOR EACH SPACE. SIGNS TO INDICATE THE MAXIMUM PENALTY MUST BE PROVIDED AT EACH ACCESSIBLE SPACE. 14. ACCESSIBLE PARKING SPACE, ACCESS AISLE STRIPING, AND INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE PAINTED BLUE (OR ANOTHER COLOR THAT CAN BE DISTINGUISHED FROM PAVEMENT). PASSENGER LOADING ZONE NOTES: 1. PASSENGER LOADING ZONES SHALL PROVIDE VEHICULAR PULL-UP SPACE NINETY-SIX (96) INCHES WIDE MINIMUM AND TWENTY (20) FEET LONG MINIMUM. 2. PASSENGER LOADING ZONES SHALL PROVIDE A CLEARLY MARKED ACCESS AISLE THAT IS SIXTY (60) INCHES WIDE MINIMUM AND EXTENDS THE FULL LENGTH OF THE VEHICLE PULL-UP SPACE THEY SERVE. 3. ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE AND NOT OVERLAP THE VEHICULAR WAY 4. VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. 5. FLOORSURFACES ACES OF VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE F FIRM AND SLIP RESISTANT. 6.VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER LOADING ZONE, AND FROM THE PASSENGER LOADING ZONE TO A VEHICULAR EXIT SERVING THEM, SHALL PROVIDE A VERTICAL CLEARANCE OF ONE HUNDRED FOURTEEN (114) INCHES MINIMUM. ACCESSIBLE ENTRANCE NOTES: 1. ACCESSIBLE ENTRANCES SHALL BE PROVIDED AS REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) AND THE NORTH CAROLINA BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS. 2. ENTRANCE DOORS, DOORWAYS AND GATES SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) THE NC BUILDING CODEIANSI A117.1 AND SHALL BE ON AN ACCESSIBLE ROUTE. PERMANENT SEEDING SCHEDULE - MIXTURE 5CP Seeding Mixture SPECIES RATE (LB/ACRE) CENTIPEDE GRASS 10-20 Seeding Dates MARCH-JUNE Soil Amendments APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 300 UNACRE 10.10-10 FERTILIZER. Mulch DO NOT MULCH. Maintenance FERTILIZE VERY SPARINGLY-20 LB/ACRE NITROGEN IN SPRING WITH NO PHOSPHORUS. CENTIPEDE GRASS CANNOT TOLERATE HIGH PH OR EXCESS FERTILIZER. TEMPORARY SEEDING -LATE WINTER/EARLY SPRING Seeding Mixture �1n�lwas"k,IIz2pywd w aaIz[I SPECIES RATE (LB/ACRE) Rye (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 60 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYONDJUNE. SUMMER SPECIES RATE (LB/ACRE) GERMAN MILLET 40 FALL SPECIES RATE (LB/ACRE) RYE (GRAIN) 12D Seeding dates COASTAL PLAIN - DECA-APR. 15 - LATE WINTER AND EARLY SPRING APRIL 15 - AUG.16 - SUMMER AUG. 15- DEC. 30-FALL Soil amendments FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10.10-10 FERTILIZER Mulch APPLY 4.000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL Maintenance REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES: NOTE: THESE EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES ARE INTENDED FOR EACH 'PHASE' OF CONSTRUCTION. THE ORDER AND STEPS TAKEN MUST BE IMPLEMENTED AS EACH PART OF THE PROJECT IS DEVELOPED; WHETHER AS A WHOLE OR IN PHASES. ANY EROSION CONTROL DEVICES/MEASURES MUST REMAIN IN PLACE UNTIL THE ENTIRE BASIN DESIGNED TO HANDLE SEDIMENTATION AND EROSION IS STABILIZED AND ALL IMPROVEMENTS WITHIN THE BASIN ARE COMPLETE. 1. CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE(S), ESTABLISH THE LIMITS OF DISTURBANCE, AND TEMPORARY SILT FENCE. 2. CLEAR AND REMOVE FROM SITE ALL TREES (ONLY ONES TO BE REMOVED), ROOTS, ROOT MAT, ETC. FROM THE AREA WITHIN THE DESIGNATED CLEARING LIMITS. INSTALL TEMPORARY SEDIMENT TRAPS AND TEMPORARY DIVERSION, CLEARING THOSE AREAS NECESSARY FOR INSTALLATION 3. INSTALL REMAINING EROSION CONTROL MEASURES AS SHOWN ON THE PLANS WITHIN THE AREA DISTURBED. ALL EROSION CONTROL MEASURES MUST BE INSTALLED BEFORE COMMENCING CONSTRUCTION. 4. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE CATCH BASIN, DROP INLET, ETC., THE CONTRACTOR SHALL INSTALL INLET PROTECTION TO STOP ANY SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM. 5. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE SYSTEM, THE CONTRACTOR SHALL INSTALL OUTLET PROTECTION AS SHOWN ON THE PLANS AND DETAILS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING AND RESTORING TO PRE-CONSTRUTION CONDITIONS ANY AREAS OUTSIDE THE PROJECT LIMITS THAT MAY INADVERTENTLY BE DAMAGED DUE TO THE FAILURE OF THE EROSION CONTROL MEASURES. 7. DURING GRADING AND AFTER GRADING HAS BEEN COMPLETED, THE CONTRACTOR SHALL CONTINUE TO MAINTAIN PERMANENT AND TEMPORARY EROSION CONTROL MEASURES UNTIL FINAL INSPECTION AND APPROVAL BY NCDENR. & UPON RECEIVING FINAL INSPECTION AND APPROVAL BY NCDENR, THE CONTRACTOR CAN REMOVE TEMPORARY EROSION CONTROL MEASURES. EDIMENT TRAPS SHALL BE FILLED ALL S IN AND SEEDED. 9. THE CONTRACTOR SHALL CONTINUE TO WATER, FERTILIZE, MOW AND MAINTAIN SPRIGGED, SODDED, AND PLANTED AREAS UNTIL ALL CONSTRUCTION IS COMPLETE. GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1. THE EROSION CONTROL PLAN SHALL INCLUDE PROVISIONS FOR GROUNDCOVER ON ALL EXPOSED PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. GROUND COVER SHALL BE PROVIDED ON ALL OTHER DISTURBED AREAS WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. 2. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. (NO SEPARATE PAYMENT). 3. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 4. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. 5. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 6. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS INCLUDING BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NGDENR FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 7. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER THE REVIEWING AGENCY OR THE ENGINEER. (NO SEPARATE PAYMENT). 8. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 9. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 10. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. 11. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 12. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER (NO SEPARATE PAYMENT). NCDENR'S FINAL APPROVAL IS REQUIRED, 13. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON -PAVED AREA (NO SEPARATE PAYMENT). 14. WHEN CROSSING CREEK OR DRAINAGE -WAY, THE DIVISION OF WATER QUALITY SHALL BE CONTACTED PRIOR TO DISTURBING A CREEK. THE CONTRACTOR SHALL INSTALL RIP -RAP WITH FABRIC ALONG DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. MAINTENANCE PLAN 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2. ALL S WILL BEPERIODICALLY D WITH AN ADDITIONAL 2 CONSTRUCTION ENTRANCE TOP DRESSED INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENT THAT IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. 3. SEDIMENT WILL BE REMOVED BEHIND THE SEDIMENT FENCE WHEN IT BECOMES 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. SILT FENCE STAKES WILL BE SPACED 6 FEET APART UNLESS A WIRE BACKING IS USED WITH 8 FOOT STAKE SPACING. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER 5. INLET PROTECTION - INSPECT WIRE AND ROCK INLET PROTECTION AT LEAST ONCE A WEEK AND AFTER EACH SIGNIFICANT (i INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. 6. SEDIMENT TRAP - REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO WITHIN ONE HALF OF THE DESIGN DEPTH. PLACE SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, PIPING, AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SPILLWAY AND POOL AREA. 7. OUTLET PROTECTION - INSPECT RIP RAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (} INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIP RAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. 8. EMERGENCY SPILLWAY PROTECTION -AFTER EVERY HIGH-WATER EVENT INSPECT THE INTEGRITY OF THE LINED SPILLWAY AND THE ADJACENT EARTHENED BANKS. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. REPAIR ANY VOIDS IN THE RIP RAP LINED APRONS, RE-ESTABLISH ANY LOOSE STONES, AND FIX GAPS IN THE ADJACENT VEGETATIVE COVER COORDINATION NOTES: 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED AND WITH BRUNSWICK COUNTY, AND THE STATE OF NORTH CAROLINA. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4. ANYTIME WORK IS PERFORMED OFFSITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. 5. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS BY OTHERS FOR ALL BUILDDNG DIMENSIONS AND DETAILS. GENERAL NOTES: 1. EXISTING CONDITIONS AND TOPOGRAPHIC SURVEY COMPLETED BY PARAMOUNTE ENGINEERING, INC. THE SURVEY SHALL BE FIELD VERIFIED BY CONTRACTOR AND ANY DISCREPANCIES REPORTED TO THE OWNER, OWNERS REPRESENTATIVE AND/OR ENGINEER IMMEDIATELY. 2. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND DIGGING ANn BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC. 3. CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT. 4. CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES' BY THE DOT. 5. ALL MATERIAL CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER O TO CONSTRUCT THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFFSITE. 6. ALL WORK BY THE CONTRACTOR SHALL BE WARRANTEED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE OWNER ACCEPTS THE WORK. 7. CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL CENTER AT 1 (800) 632.4949 AN ALLOW THE CENTER TO LOCATE EXISTING UTILITIES BEFORE DIGGING. SITE NOTES: 1. ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, EASEMENTS AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 2. CONTRACTOR HALL MAINTAIN THE SITE IN A N S MANNER SO THAT WORKMEN AND PUBLIC SHALL BE PROTECTED FROM INJURY, AND ADJOINING PROPERTY PROTECTED FROM DAMAGE. 3. ACCESS TO UTILITIES, FIRE HYDRANTS, STREET LIGHTING, ETC., SHALL REMAIN UNDISTURBED, UNLESS COORDINATED WITH THE RESPECTIVE UTILITY. C DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 5. THE GENERAL (.JNTRACTOR SHALL REMOVE ALL DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION. 6. THE GENERAL CONTRACTOR SHALL KEEP THE AREA OUTSIDE THE "CONSTRUCTION LIMITS" BROOM CLEAN AT ALL TIMES. 7. ALL UTILITIES Ti; SERVICE PROPOSED STRUCTURE SHALL BE UNDERGROUND ON SITE. 8. ALL STREET SURFACES, DRIVEWAYS, CULVERTS, CURB AND GUTTERS, ROADSIDE DRAINAGE DITCHES AND OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED IN ACCORDANCE WITH THE SPECIFICATIONS. 9. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE OWNER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE ENGINEER. 10. IF DEPARTURES FROM THE SPECIFICATIONS OR DRAWINGS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREOF SHALL BE GIVEN TO THE OWNER FOR REVIEW, NO DEPARTURES FROM THE CONTRACT DOCUMENT SHALL BE MADE WITHOUT THE PERMISSION OF THE OWNER. 11. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALL EXISTING UTILITIES ARE NOT NECESSARILY SHOWN ON PLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THE CONTRACTOR SHALL ON HIS INITIATIVE AND AT NO EXTRA COST HAVE LOCATED ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. NO CLAIMS FOR DAMAGES OR EXTRA COMPENSATION SHALL ACCRUE TO THE CONTRACTOR FROM THE PRESENCE OF SUCH PIPE OTHER OBSTRUCTIONS OR FROM DELAY DUE TO REMOVAL OR REARRANGEMENT OF THE SAME. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND STRUCTURES. CONTACT NORTH CAROLINA ONE CALL" TOLL FREE 1.800-632-4949 AT LEAST 48 HOURS OU S PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL NONSUBSCRIBING UTILITIES. 12. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL INSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC., THAT MAY BE REQUIRED. 13. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 14. ALL LOT STRIPING AND DIRECTIONAL ARROWS TO BE WHITE REFLECTIVE MARKINGS AND SHALL CONFORM TO NCDOT. 15. ALL PARKING LOT DIMENSIONS ARE FROM FACE OF CURB. 16. LANDSCAPE PLANTINGS AT ENTRANCE/ EXITS WILL BE INSTALLED AND MAINTAINED SO AS NOT TO INTERFERE WITH SIGHT DISTANCE NEEDS OF DRIVERS IN THE PARKING AREA AND AT ENTRANCE/EXIT LOCATIONS PER LOCAL STANDARDS. 17. SEEDING TO BE INSTALLED TO LOCAL REQUIREMENTS & STANDARD PRACTICES. 18. ALL DIMENSIONS AND RADII ARE TO OUTSIDE FACE OF BUILDING OR TO FACE OF CURB, OR GUTTER LINE, UNLESS OTHERWISE NOTED. TRAFFIC NOTES: 1. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS -OF -WAY & FOR DRIVEWAY(S) ARE TO BE THERMOPLASTIC & MEET NCDOT STANDARDS. 2. 3. 4. 5. TRAFFIC CONTROL DEVICES (INCLUDING SIGNS AND PAVEMENT MARKINGS) IN AREAS OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCO (MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES) STANDARDS. ALL TRAFFIC CONTROL SIGNS AND MARKINGS NOT WITHIN THE PUBLIC RIGHT-OF-WAY ARE TO BE MAINTAINED BY THE PROPERTY OWNER ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS SHALL BE WHITE. TACTILE WARNING MATS TO BE INSTALLED AT ALL WHEELCHAIR RAMPS. �..`"'*� Iz •, NPDES WATER QUALITY STABILIZATION TIME FRAMES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES 7 DAYS NONE HIGH QUALITY WATER (HOW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE, EXCEPT FOR PERIMETERS AND HOW ZONES N z O UJ W � N z 0 F+i o .✓ W w Fri O LL (Y� z W Od J U ON Z N r Z u O � 0 V"CpN W -4 ,� W zo 5 F-+ l� 1�1 W O ? O� i 04 Z (rt � O W �W �i w w �Dz O U mod- U w� zH �o �z O az Q 00 Z O (n $ LL Z F <g 2 U FNo U' Z_ o WgJayQ�QJ Z J¢ Q} zzW F Q N W z J Q. UatL� 0 ONI]aU SEAL CA L r LU Q ri C-1.0 PEI JOB#: 12293.PE VICINITY MAP (NOT TO SCALE) = EXISTING PROPERTY LINE = SETBACK LINE = PROPOSED CONCRETE SIDEWALK = PROPOSED BUILDING FOOTPRINT = PROPOSED BUFFER AREAS = OPEN SPACE = 404 WETLAND LINE = 404 WETLANDS = COASTAL WETLAND LINE = COASTAL WETLANDS 24" CURB AND GUTTER (REVERSE SLOPE, SEE DETAIL) BATH GRAPHIC SCALE SCALE: 1 lu •PROPOSED O WOODEN N WALKWAY PROPERTY BOUNDARY k'Y rU 7 R` 25 60'R 3'R 3 13 3'R 5'R m 9' TYP. Rl 3' 81 Ty 3 � 25' MEAN HIGH WATER I PROPOSED s WOODEN WALK WAY •�� COASTAL � j �' WETLANDS�� 4 4 A 4 \ y\ r RPM �109'R 29'R ' 5' PROPOSED STORMWATER POND CONCRETE SIDEWALK i / I PROPOSED RETAINING WALL (DESIGNED BY OTHERS) Y m w) O 0 I }I w I y G BRUNSWICK RIVER \N 4 4 q_\ \ COASTAL / O �\•\ WETLANDS (\ 8 i\.\ N\\'` \ \\\\.\.\.\\ \\\.N\ NN 1'R 22' EP-EP BENDING RIVER WAY PRIVATE R/W (WIDTH VARMS) 09'R �— / O PROPOSED MODIFIED (VALLEY CURB (TYP.) S17'54'57"E 527.15' `-PROPOSED MODIFIED VALLEY CURB (TYP.) 25' FRONT SET BACK (TYP.) % O 25REAR SET BACK (TYP.d L Om SITE INFORMATION PROJECT NAME: PROPOSED USE: DOCK ACCESS AREA: RESIDENTIAL AREA: TOTAL SITE AREA: PARCEL ID: APPLICANT INFORMATION PROPOSED UNITS HAWKESWATER AT THE RIVER - PHASE 4 RESIDENTIAL 2.59 ACRES 4.66 ACRES 7.25 ACRES 048CA02001 D.R. HORTON 4073 BELLE TERRE BLVD. MYRTLE BEACH, SC 29579 DIMENSION REQUIREMENTS FRONTYARD SETBACK: 25' (FROM RIGHT OF WAY) SIDEYARD SETBACK: 10, REARYARD SETBACK: 26 BUFFERYARDS REQUIRED: IV PERIMETER BUFFER 20' STREET BUFFER _O O w Q w GENERAL NOTES w 1. THIS SITE DOES NOT LIE WITHIN ANY DESIGNATED FLOOD ZONE. 1.4 2. ALL PROPOSED EXTERIOR LIGHTING SHALL MEET THE MINIMUM DESIGN REQUIREMENTS AS PER SECTION 6.6.5 OF THE LIDO. 3. H2GO WILL BE THE UTILITIES PROVIDER FOR WATER AND SEWER. 4. WATER MAINS WILL BE 6-INCH AND SEWER MAINS WILL BE 8-INCH. WATER SERVICES WILL BE 1-INCH WITH k METERS & SEWER SERVICES WILL BE 4-INCH. O 5. ALL RADII ARE LABELED AT VALLEY OF CURB. z 1 V H w ECErVI� Q ii��M1 j PAV 8 BY:-------_ 4-i 1--�I w z 0 w G1 N � O �x O F 1 eG xa� 0 xaw z wa a W H u- m Q Z z Z It w U wV iz � M NZN �� m �cn FF'rr O w A^ V U �Wz oo'� ZZo1�)"z r- W �z� o^ ��11A W W I zz Oa U �Q �4 P.4 =�UU W�`nZ 4z tD 'pLL LL(j Zn33�~ U) F- 5� z F Oy O LL z U)55..0 L)�Wgw Z ayo WLU goW ZM�ll W _ p ZZ �LLI 1 N W 0. 00.. ILK o gViO�U SEAL „ •, ;.,:,:, CA ` S AL . z-i 4t �'•.F e. Q C-200 PEI JOB#: 12293.PE LEGEND: -- --- 21 -- --- EXISTING CONTOUR 21 PROPOSED CONTOUR EG=27.90--_�, EXISTING SPOT ELEVATION EP=26.90--__�. PROPOSED EDGE OF PAVEMENT EL. PG--27.00-,-. PROPOSE SPOT ELEVATION FL=26.50--�, PROPOSED GUTTER ELEVATION SW=25.90--�. PROPOSED SIDEWALK ELEVATION TC=25.90--,-. PROPOSED TOP OF CURB ELEVATION HP=25.75----, HIGH POINT ELEVATION LP=24.75----.. LOW POINT ELEVATION INLET PROTECTION - LOD- LIMITS OF DISTURBANCE - o--Q-¢ - SILT FENCE CB 21 INLET LABEL NOTATION: DI = DROP INLET YI = YARD INLET CI = CURB INLET DCI = DOUBLE CURB INLET MH = STORM DRAIN MANHOLE CO = CLEANOUT FFE = FINISHED FLOOR ELEVATION BPE = BUILDING PAD ELEVATION FES = FLARED END SECTION 24" CURB AND GUTTER (REVERSE SLOPE, SEE DETAIL) LIMITS OF DISTURBANCE%���-� (TY?a If 1 CRU9aED �- Wd - WJ �: If �i - i i -• r\ r� --v \ EAN HIGH WATER / • 3 � �•.,� � ;, � ,\'� . LINES ____ / I • • PROPOSED 1 WOODEN WALK WAY 3 3� S ARTS AT 50 ;b ' 10 VEG §ET•$ACI� PROPOSED + , •\�/ CONCRETE WALKWAY I a � • FAIRCLOTH SKIMMER \•\'\• \\' \' • ' . : VINYL SHEET PILE V FOREBAY WALL (BY ` • -` OTHERS) CONFIRM WITH \•\\\\\• - ''STRUCTURAL ENGINEER\• \ 9 5b'STORMWA \ 1) X\�;\ BUFFER i T POOL -ELEV. = TW�16.Oa 7,/ El 47 PROPOSEDOf i ,DIVER/SIRONN DITCH I Titer19 ! \ =16.w m,> PG--24.a2 G 1 SS------ S - • • EASEMENT CONSTRUCTION ENTRANCE 0iTa:>lii�C1 \\\X.V � • • \ ti SILT FENCE \\ cryP.)V. I \' 4 AfiER 2 - 1 EMEPIT\ -� 11PROPOSED _ TEMPORARY'__- - D[VERSION DITCH Q` -�� G--23 25� G--22.7/1 V G =23 h I PG-23.82 S LIMITS OF \� CONSTRUCTION 5.83ACRES rj> zc [O EXIST G PUMP / STATION C15 p / \ �J SS INV=23.16 PERMANENT POOL LINE/CURVE TABLES: LINE TABLE LINE BEARING DISTANCE Li S19'1a1YE 17.38' L2 N46022WOE 9.44' L3 N68*OZ11'E 30.94' LA N72"16'570E 11.0 L5 N3rS928"w 108.32' L6 N29037Y2"W 13.21' L7 N30"05'03"W 023' L8 S84°2175"W 14.6a' L9 S30"5a52'E 1'M " CURVE TABLE CURVE LENGTH I RADIUS I CHORD DISTANCE C1 42.15 1 209.W I N25"05TM 42.W C2 13.33' 1 6.33' 378°68'550E 11.w C3 929' 24.W Wr10`16'W 9.24' 04 10.W 5.8T N160W41-E 9AW 05 16.w 76.21' S220ST561E 16.W C6 10.31Y 19.36' N3W40'02'W 10.18' C7 37.74' 92.Or N60"2VS7"W C8 28.10 67.55' N85"39'16wWC9 JEJ 1fi.09 7.81' 327°2T52W STORM SEWER TABLE From To -Length Material Pipe Size Slope Inv. Down Inv. Up Rim Down Rim U ft in % ft ft ft ft JB 1 FES 1 24 RCP CL. 111 30 0.45 3.54 3.65 3 8 CI 1 JB 1 231 RCP CL. 111 30 5.35 3.65 16 8 23.98 DCI 2 Cl 1 83 RCP CL. 111 24 0.46 19.7 20.08 23.98 23.94 Cl 3 DCI 2 118 RCP CL. 111 15 0.44 20.08 20.6 23.94 24.57 DI 1 Cl 3 188 RCP CL. 1111 15 0.45 20.6 21.45 24.57 24.2 C14 DI 1 72 RCP CL. III 15 0.72 21.45 21.97 24.2 24.9 C15 CI 4 40 RCP CL. 111 15 0.45 21.97 22.15 24.9 24.9 DI 2 JB 1 150 RCP CL. 111 15 0.45 4.53 5.2 8 . 8 Cl 6 Cl 1 95 RCP CL. ill 15 0.46 19.44 19.88 23.98 22.76 Cl 8 DCI 2 25 RCP CL. III 15 0.44 21.08 21.19 23.94 23.94 CI 7 CI 6 28 RCP CL. III 15 0.45 19.88 1 20.01 22.76 22.76 rmuvlut i-rvv I ziumv IN ALL L:UKt3 INL.t I AND DROP INLET STRUCTURES RIMS SHOWN ON PLANS ARE EOP AT INLET LOCATION - NOTES: 1. ALL CONSTRUCTION WITHIN THE RIGHT OF WAY SHALL BE DONE IN ACCORDANCE WITH BRUNSWICK COUNTY STANDARDS AND _� YV W W VJ-'�1��� -gE - *" -- __ lh ��- Vd W Ill _ SPECIFICATIONS. / T -24 2. THE CONTRACTOR iNv at'10�' STORM DRAIN INLETS TO PROTECT THE SYSTEM FROM COLLECTING f INV�21,_-�17 � n �n�-- -_- SEDIMENTATION DURING CONSTRUCTION. INLET PROTECTION SHALL 2C ?�`= S� -ma^uw. c -^ -_- sZ- REMAIN IN PLACE UNTIL THE PARKING LOT IS PAVED. WET DETENTION / SEDIMENT BASIN NOTES: "S �,, _ 25- 2 J S \ -� �`''1-,- . _ = _- = = - - 1. THE PROPOSED WET DETENTION POND SHALL BE USED DURING /�--� -ZS - 3 ALL PROPOSED SPOT ELEVATIONS VATISS NOTED ARE PROPOSED EDGE OF /� � � PAVEMENT ELEVATIONS, UNLESS NOTED OTHERWISE. CONSTRUCTION AS A SEDIMENT BASIN UNTIL THE SITE IS FULLY / -' - � N � 4. ALL ROOF DRAINS SHALL BE DIRECTED MfrO STREET VIA GUTTERS, sTAB1uzED. / \ I I LEADERS AND UNDERGROUND SCHEDULE 40 PVC CONDUIT, IF / / ° �� NECESSARY. NO ROOF DRAINAGE SHAD. DISCHARGE DR PROPOSED DEPTHS OF THE WET DETENTION POND AS ILLUSTRATED THE WET DETENTION BASIN. CONTRACTOR SHALL COORDINATE WE WITH 2. THE CONTRACTOR SHALL CONSTRUCT THE SEDIMENT BASIN TO THE ARCHITECTURAL PLANS FOR ROOF DRAIN CONNECTION POINTS. ON THE PLANS AND INSTALL THE PROPOSED OUTLET STRUCTURE. ONCE THE OUTLET STRUCTURE IS IN PLACE, THE CONTRACTOR 5. ALL SIDEWALK CROSS SLOPES HAVE BEEN GRADED MEET AEA GRAPHIC SCALE REGULATIONS. CONTRACTOR SHALL CONFIRM GRADES BEFORE SHALL IMMEDIATELY INSTALL THE SKIMMER TO THE PERMANENT G 20 40 an D PLACING PAVEMENT OR SIDEWALKS POOL DRAWDOWN ORIFICE. SCALE: 1 n=40' 6. THE CONTRACTOR SHALL USE EITHER RCP (CL 111) OR HDPE PIPE FOR 3. ONCE THE SITE IS STABILIZED THE CONTRACTOR SHALL REMOVE ALL THE HDPESTORP DRAINAGE SYSTEM. IF THE CONTRACTOR CHOOSES TO SEDIMENT FROM THE BASIN AND ESTABLISH THE FINISHED GRADES USE HDPE PIPE, IT SHALL BEADS N-12 -12 ST F M PIPE FOR PIPE DIAMETERS 12" OR LARGER AND ADS N-12 ST FOR DIAMETERS 4•-10' OF THE PROPOSED WET DETENTION POND. SPECIFICATIONS. APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS. IN ADDITION, THE CONTRACTOR SHALL BE SURE TO PROVIDE CONCRETE COLLARS AROUND EACH F.E.S. TO PREVENT 4. REFER TO THE SEDIMENT BASIN DETAIL FOR THE REQUIRED FLOATAMON IF HOPE PIPE IS CHOSEN. SEDIMENT REMOVAL ELEVATIONS DURING CONSTRUCTION. 7. WETLANDS EXIST ON THE SITE AS DELINEATED AND APPROVED BY THE U.S.A.C.O.E. 8. ALL RUNOFF FROM IMPERVIOUS SURFACES SHALL BE COLLECTED AND CONVEYED TO THE ONSITE STORM WATER POND. ECEIVEIN MAY i J 2JA BY: <Q N � f � U z U 0 0 m z 0 0 O zgo o a d m Ln N x xa� xaw way LOL O z w U wV �2 � N N ti «t r 00 z� 0 A� wV,bC2O W , cd p"p Zzo °"oU o°� �z J Ln' O W s� W W �z Q � U0 u � W�x �z v w b a LL i Z It 3; '8 01 O) s FA1a r LL Ww� Z w o 22Y ZJ" 1'• NQW p�OGU S ��NCO ��� !i -� zu yG• CL\�c'.'" nn,„�,.nu�:a•. c-3.0 PEI JOBM 12293.PE LEGEND: - - 21 -- --- EXISTING CONTOUR 21 PROPOSED CONTOUR EG=27.90--_�. EXISTING SPOT ELEVATION EP=26.90---__�. PROPOSED EDGE OF PAVEMENT EL. PG=27.00--__�, PROPOSE SPOT ELEVATION FL=26.50--_�, PROPOSED GUTTER ELEVATION SW=25.90----,. PROPOSED SIDEWALK ELEVATION TC=25.90--,-. PROPOSED TOP OF CURB ELEVATION HP=25.75-1, HIGH POINT ELEVATION LP=24.75-----. LOW POINT ELEVATION n INLET PROTECTION - LOD- LIMITS OF DISTURBANCE - --D_ - SILT FENCE CB 29 INLET LABEL IMPERVIOUS AREA DRAINAGE AREA BOUNDARY NOTATION: DI = DROP INLET YI = YARD INLET CI = CURB INLET DCI = DOUBLE CURB INLET MH = STORM DRAIN MANHOLE CO = CLEANOUT FFE = FINISHED FLOOR ELEVATION BPE = BUILDING PAD ELEVATION FES = FLARED END SECTION 24" CURB AND GUTTER (REVERSE SLOPE, SEE DETAIL) S7, i i i i i i i i i i j\ 0 \ ►MEAN HIGH WATER LINE`_ r7 \\,�'\��:\\'�\ i.50'STORMWATER i i i i i i i i i. \'\ r /- - BUFFER \,\\\' ' .\\.�: i i i , ��� ` E,, / � 4 \;\\ ZI DA: 0.53 AC� VALUE: i i i i i i /, / l✓ STORMWATER POND7 i i :o` �\_J r C­VALUE: 0.>342�,�_- ul IL \? \�r6 � ! oat ) w WA CI3_ f 4DA: 0.17 AC `C-VAL/UE: 0.74 0 DCIB DA: 0.62 AC / \ C-VALUE:0.60 DI \ 1 t DA. 0.27 AC r C VALUE: 0.85 O Jv \\ ( �J ' C15- m DA: 024 AC 4\ % DI, N ( C-VALUE:0.62 r \� 05 ( % 1 C14 awSNEnI DA: 0.03 AC::� C-VALUE: 0.72 iNV=21.17 1� �4 4Y kk D2 10- 7 -- --i2- \\ , C16��- OA 0.240 C-VALUE: �� 4f C17 ; l i f lI Z ZV !ri CI 7 DA: 0.80 AC z O tom! C-VALUE: 0.54, f ;t- r 1•-- `, J W 14 i - Vr --^ -2�[f _ 44' Vt - rn� rW� -24 INV-21.10 N� __��._ �'---SSW' _= ut.�_ � .GS YJ-) • r GRAPHIC SCALE SCALE: J1 "--40' V 5..3( POND DRAINAGE AREA = 276,065 SCL FT. STORM SEWER TABLE From To Length Material Ifte Size Slope Inv. Down Inv. Up Rim Down Rim U (ft) (in) (%) (ft) (ft) (ft) (ft) 181 FFS 1 24 RCP CL. 111 30 0.45 3.54 3.65 3 8 CI 1 1B 1 231 RCP CL III 30 1 3.65 5.96 8 23.98 CI 2 CI 1 83 RCP CL 111 24 0.46 19.7 20.08 23.98 23.94 CI 3 CI 2 1 118 RCP CL. III 15 0.44 20.08 20.6 23.94 24.57 DI 1 CI 3 188 RCP CL III 15 0.45 20.6 21.45 24.57 24.2 CI 4 DI 1 72 RCP CL 111 15 0.72 21.45 21.97 24.2 24.9 CI 5 CI 4 40 RCP CL III 15 0.45 21.97 22.15 24.9 24.9 DI 2 1B 1 150 RCP CL III 15 0.45 4.53 5.2 8 8 CI 6 CI 1 95 RCP CL III 15 0.46 19.44 19.88 23.98 2276 DCI 8 CI 25 RCP CL 111 15 0.44 21.08 21.19 23.94 23.94 CI 7 C16 28 RCP CL 111 15 0.46 19.88 20.01 22.76 22.76 - FKUVIUE 1+UQr SUMP IN ALL CURB INLET AND DROP INLET STRUCTURES ECEIVE ?, BY: Z W M z O 55 W Ir WV iz M NZ �o N 00 N 19t+ a �0' 00 N z pr, e tjsV I< bz° �+ w Z a c o ;,j `y z ;e �z A w z � oa W �4 P4 Uu � w�x Q P.Pq°z �OLLLL(J z Ell33(~7 O kk Q Q o3 O 1•- ,.5 25 Z Z_ WH 11yy22yO IL Ez av29= SEAL .o...... mn",n•...... C.3*1 PEI JOB#: 12293.PE Y STAKEOUT POINT ASPHALT CONCRETE STEELENCASEMENT 6" CONCRETE CURB INLET PIPE LOSE END WITH 8" ° �70' (STD. 840.03) BRICK MASONRY ° a n ' CARRIER PIPE a4" MOD. VALLEY 12" d° CURB & GUTTER SLOPE TO DRAIN FORM GUTTER TO MATCH HOOD 2" WEEP 30'R T 30'R 5' S' CARRIER PIPE SUPPORTS HOLE 6 6 /\\/\\/\\/ SIGHT SIGHT ARE TO BE PLACED AT TRIANGLE TRIANGLE T � //\ COMPACTED SUBGRADE TO 20' 2' 2'-6' o 0 12' 3 UNITS PER JOINT OF PIPE /i ��i ��i �i 95%STANDARD PROCTOR 1 12• ELEVATION VIEW LENGTH OF CASING PIPE SHALL EXTEND FROM DITCH LINE TO DITCH LINE, 5 FEET BEYOND TOE OF ANY SLOPE AND, TYPICAL STREET INTERSECTION WHERE NO DITCH LINE OR FILL SLOPE IS PRESENT, A MINIMUM OF 10 FEET BEYOND ANY EXISTING EDGE OF PAVEMENT. ASPHALT TO CONCRETE PAVEMENT TRANSITION CONTRACTOR SHALL TRANSRIONFROMMOD. NOT TO SCALE NOT TO SCALE MAINTAIN EDP & TRANSITION VALLEY CURB & GUTTER TO Uj THE GUTTER LINE FOR CURB MATCH CURB INLET z INLET INSTALLATION INSTALLATION \� ��j\y�\/� \� \ O SPIDER SUPPORT AND /\i�/ \\// STEEL ENCASEMENT > Lu 50FTRW CURB TRANSITION DETAIL SPACER j\ \ jam\ PIPEIt NOT TO SCALE 12 2' 22' 2' 12' V-0" 5' MIN. SLOPES=VARIES 3:1 MAX V4' PER FT 1/4' PER FT 1/40 PER FT ffa• PER Fr SLOPES=VARIES 3:1 MAX MIN. FLUSH W/ MIN. ASPHALT CARRIER PIPE TOP WIDTH z-m Z ( 7 MODIFIED VALLEY 764BM208 RFACE 6' ABC UNDER (n ° SECTION VIEW CURB (TYP.) . BASE CURB (TYP.) a d a ' 4' FREEBOARD O ,_^ ' 4�.E-4 10%SETTLEMENTSLOPE aPE"a . e ° FLOWTYPICAL ROAD CROSS SECTION e . ' ' ` d frMlKLANESPAVING - ONE ORTWOa . , n .. ° a7:fPROTECTED .......AREA W/ MODIFIED VALLEY CURBING ° ° a """ fr W NOT TO SCALE P� CARRIER 3' MIN. BELOW SUBGRADE TEMPORARY DIVERSION DITCH 3' MIN. PIPE TURNDOWN SIDEWALK HANDICAP RAMP \" �//� NOT TO SCALE NOT TO SCALE /\� / /�\` \/ �` /� ` / i Z L` / \ 2" S9.513 SURFACE w J D� U tW � COURSE 6" NCDOT CRUSHED STONE AGGREGATE BASE COURSE 100% ASTM D698 / /// //\//\/� `\� NOTE: REFER TO PLANS BRICK CARRIER PIPE \�X//: /\\' l�\i\ i \i\�7\\i. COMPACTED SUBGRADE ` FOR LENGTH OF STEEL CLOSURE STEEL CASEMENT F T 1 U PIPE w 2 u \ 12:1 MAX CASING PIPE 0 100% ASTM D698 TO PAVEMENT 'CURB rn 12 DEPTH r �• PROFILE VIEW 2 r• o 0 N N SECTION A -A BORE AND JACK DETAIL ii " PAVEMENT SECTION A z 0 � Oo NOT TO SCALE NOT TO SCALE 10:1 -w.CJ�k 3 0. o z A\ / 1T 0 C5 CN Lo 61 o ° o ¢a ss�sx "JW� COMBINATION STRAIGHT AND COURSE LEFT OR RIGHT TURN ARROW a 6- 24' WHEELCHAIR RAMP (DROP CURB) zY 24" CURB AND GUTTER NOT TO SCALE RIGHT OR LEFT (REVERSE SLOPES STRAIGHT ARROW TURN ARROW � NOT TO SCALE 84•' n t4 0 2'-0' 'r I 1'-0•Tl'-0. GENERAL NOTES: 14' 14• R40 m r T-- CONTRACTION JOINTS SHALL BE SPACED AT MAX. 10' INTERVALS, EXCEPT THAT A 15 �e 11�1' LLJ' l FOOT SPACING MAY BE USED WHEN A MACHINE IS USED OR WHEN SATISFACTORY 4 <:(l z SUPPORT FOR THE FACE FORM CAN BE OBTAINED WITHOUT THE USE OF TEMPLATES D.S. MIN a °' _ J 6" `c�� AT 10 FOOT INTERVALS. JOINT SPACING MAY BE ALTERED BY THE ENGINEER TO D>acMax r sr 1r-YI. PREVENT UNCONTROLLED CRACKING. CONTRACTION JOINTS MAY BE INSTALLED BY P { w � a `D THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH N 'r "` JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1-1/2" SHALL BE IOR4 E °� ii e-0 C%� s.:�r" . >y f.,, >y 1s. ~ 6' AGGREGATE BASE COURSE " " +s.• i UNDER CURB. OBTAINED. ALL CONTRACTION JOINTS EXCEPT IN 8 X 6 MEDIAN CURB SHALL BE narERw eACKFLL �j �j x� '•" ."N r �' FILLED WfFH JOINT SEALER. EXPANSION JOINTS SHALL BE SPACED AT 90' INTERVALS u AND ADJACENT TO ALL RIGID OBJECTS. COMBINATION LEFT AND U STRAIGHT AND RIGHT TURN ARROW MODIFIED VALLEY CURB �� '����. . "- �=r l ;T F CLASS I NOT TO SCALE CONCRETE ;µ is Da U W rTl FT'j�' PMw.6i'i^i.. s•MIN. �j T I!1`F�YJyj11 �WN1 rI_''•1 CLASS "A" CLASS "B" COMBINATION LEFT F+i H 10' SKIP LINES AND RIGHT TURN ARROW M YELLOW OR WHITE W t0 uj LL LL U GORE LINE 11`_ , zO CLASS®�® W a WHITE ��0' I.II OR III H IA OAR" H Of SACKFU "ApffLL /- 4~i O DIAGONAL LINE �40�� ,¢- g z EDGE LINEJ D14 "3 Dw 2' MINI -SKIP LINES a o z o YELLOW OR WHITE YELLOW OR WHITE lanes., O O U di 3 YELLOW OR WHITE CROSSWALK LINE m I? 1�" e� Azµ rr; ORM d'MN. , Z as w W a ¢ W _ "' GENERAL NOTES z a 8 a LL a o woo U -ALL PAVEMENT MARKING SYMBOLS SHALL BE WHITE IN COLOR F�-1 -PAVEMENT MARKING SYMBOLS SHALL NOT BE LOCATED AS TO I SEAL TURN LANE LINEJ 13 CLASS licit CLASS "D" ENCROACH INTO INTERSECTION AREAS. 'GAR"• WHITE 15 -ON PORTLAND CEMENT CONCRETE PAVEMENTS, PAVEMENT MARKING ......... O SYMBOLS SHALL NOT BE PLACED ACROSS TRANSVERSE EXPANSION S WHITEt STOP OR TRANSVERSE BAR JOINTS UNLESS APPROVED BY THE ENGINEER. 'y r $N0Dl APPLIES WHBK two VIUM AM 8�'J11FD. THE FIRR BEDDoN o DEE AILS c% m wmPLIES FOR A 'NORMAL• wIDIH uNE THE sEcorro �T� `2�. '•. lS,l C� ( J CENTER LINE N WORT APPLIES FOR A VW IMF- 'IeDE' U S ARE F�•1 = o ' ..I°lyV ti, � *B DI3WM IN X PIANs, OR WM PAVEMENT MARKINGS Dffm BY 11E ENgm cll� ARROW SYMBOLS YELLOW WHITE NOT TO SCALE `.: ,i - 20I3 PAVEMENT MARKINGS 8Y: I C - 5.0 LINE TYPES NOT TO SCALE �T F•�-1 PEI JOB#: 12293.PE f ALL OUTLET PIPES SHALL HAVE FLARED END SECTIONS NCDOT #5 OR #57 WASHED STONE A FILTER FABRIC J N.C.D.O.T. CLASS B SECTION RIPRAP, MINIMUM 18" THICK, TYPICAL RIP —RAP SCHEDULE UPSTREAM DOWNSTREAM PIPE DIA. (IN.) LENGTH (FT.) WIDTH (FT.) WIDTH (FT.) OUTFALL 30 10 7.5 7.5 FES 1 18 10 4.5 6 Kir-KAI"' XI-"KUN NOT TO SCALE STAKE TO SUPPORT WIRE �4(� STEEL POSTS TOP WIRE TO PREVENT SAGGING COIR EROSION CONTROL BLANKET (5-10% OPEN SPACE) -I I I_I I I -I I I r , , I I I, ,, I 11, , 1 _I I— BOTTOM EDGE TO BE TRENCHED OR SECURED WITH STAPLES NOTES: L INSTALL POROUS BAFFLES IN SEDIMENT TRAP AS REQUIRED 2 INSTALL ONE CONTINUOUS PIECE OF FABRIC ACROSS THE ENRRE MIN -DO NOTSPUCE [resigned Per NCDENR Erosion Control Design Manual (6.65)] Requirements: Inlet: 35% of Surface Area Chamber 1: 25% of Surface Area Chamber 2: 25% of Surface Area Outlet: 15% of Surface Area TSB # Surface Area Length Width In et Area Chamber 1 Chamber 2 Outlet Bade #1 Sells #2 Bafle #3 (SF) (FT) (Fr) (SF) Area (SF) Area (SF) Area (SF) (Distance from End) 0''O (Distance from End) (FT) (Distance from End) (FT) TSB #1 12,737 195 65 4,458 3,184 3,184 1 1.911 1 49 1 49 L 49 POROUS BAFFLE DETAIL NOT TO SCALE e ?Orr (4) FASTENERS REQUIRED PER SECTION, (2) TOP AND (2) BOTTOM, SIGN TO BE MOUNTED WARNING TO RETENTION POND FENCING. HEAVY DUTY TIES TO BE USED €c DO NOT ENTER NO SWIMMING RADNSCORNER(S) GENERAL SPECIFICATIONS: .080" SINGLE FACE FLAT ALUMINUM DOUBLE PANEL LINEAR WALL SIGN WITH VINYL GRAPHICS IN COLORS AS SHOWN COLORS: BACKGROUND -GREEN (TBD) LETTERING - WHITE RETENTION POND SIGNAGE NOT TO SCALE }' WIRE MESH coBOX NIG 19-GUAGE HARDWARE CLOTH MESH OPENING 16-18 INCHES OF NCDOT #57 WASHED STONE NOTE: FOR CURB INLETS AND DROP INLETS INLET PROTECTION NOT TO SCALE Gy!I"VI SECTION A - A 5' STEEL POST (SELF -FASTENER STEEL ANGLE TYPE) rLANIN VICVV NY MIN. 6" DIVERSION TO DIRECT RUNOFF FROM RIW SECTION VIEW TEMPORARY CONSTRUCTION ENTRANCE NOT TO SCALE ATTACH SKIMMER TO THE LOW LEVEL ORIFICE (EL. = 6.00) DRAWDOWN VOLUME 6" FAIRCLOTH SKIMMER (OR EQUAL) MAXIMUM LEVEL OF SEDIMENT COLLECTED EL. 14.75 TO EL. 12.(* CLEAR BASIN WHEN THIS LEVEL IS REACHED. ORIFICE DIAMETER =1.75" (SEE DETAIL) -� I- - - - - - - - - - - -- - - - - - - - - ---- - - - - - - - - - - - - - - - --- - -II II — — — — — — — — — — — 7' SEDIMENT STORAGE ZONE (TOTAL BASIN CAPACITY) =I— "----- -- FL3.5' MAX SEDIMENT DEPTH BOTTOM ELEVATION =-1.00 11 ' —III IIIII iIIII IIII IIII II�III III �II�IIII III III�IIIII�II�II�III I�I� II�,III= STORM DRAIN OUTFALL SEDIMENT BASIN DETAIL NOT TO SCALE SUITABLE PLANTS WET DETENTION POND PLANTING PICKERELWEED (PONTEDERIA CORDATA) CONTRACTOR TO INSTALL ON THE 10:1 SLOPED DUCK POTATO (SAGGITARIA LATIFOLIA AND SAGGITARIA CARDINALIS) SHELF, EQUAL NUMBERS OF EACH SWAMP ROSE (HIBISCUS MOSHEUTOS) OF THE LISTED SUITABLE PLANTS. WRING BLUE FLAG (IRIS VIRGINICA) INSTALLATION, GROUP SIMILAR SPECIES OF CARDINAL FLOWER (LOBELIA CARDINALIS) PLANTS TOGETHER. INSTALL PLANTS 24" O.C. IN A CHECKERBOARD PATTERN. SOD ALL SLOPES ABOVE PERMANENT POOL EL. 10:1 SHELF 6" ABOVE & 6" BELOW PERMANENT POOL PLANTED WITH SUITABLE WETLAND _ SPECIES OR VEGETATION. 11—III= 311 —11 za POND r 1 I - POND SIDE SECTION NOT TO SCALE P.ELFOREBAY-6.00 OVERFLOW EL. = 7.50 — _ TEMPORARY POOL EL. = TO — _ 1.5" RUNOFF STORAGE EL. = 6.90 _ '— PERMANENT POOL EL. (NORMAL WATER SURFACE) 6.00uj _ CL IS Alt itorl FOREBAY MAIN POND 3 a 1Jj BOTTOM EL. FOREBAY = -1.00 POND BOTTOM EL. = 1.0 1'OF POND DEPTH IS FOR FOREBAY IS DIVIDED FROM THE SEDIMENT STORAGE EL. = 0.0 SEDIMENT ACCUMILATION MAIN POND BY A SHEET PILE PER OWQ POLICY POND - FOREBAY AND STORAGE POND SECTION NOT TO SCALE TO LOW LEVEL ORIFICE FAIRCLOTH SKIMMER DETAIL NOT TO SCALE OVERFLOW STRUCTURE (SEE DETAIL) VEG SHELF 10:1 SLOPE TYP. AROUND POND RISER SPILLWAY RISER (SEE OUTLET STRUCTURE DETAIL) ------- tT TOP EL. 8.00 EMERGENCY SPILLWAY TOP OF RISER = 7.5 (4%4' GRATE OPENING) 5' WEIR SECTION OPEN — ON 3 SIDES OF STRUCTURE ELEV. = 7.00' 2" SCH. 40 PVC— DRAWDOWN ORIFICE I � z �Q O z J VARIES AS DIRECTED BY ENGINEER (6 MAX.) TOP STRAND MIN. STAY WIRES MIN. #10GUAGE� "-,J- #12-1/2GUAGE BOTTOM STRAND MIN. #10 GUAGE NOTES: 1. WIRE SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES W/12" STAY SPACING 2. FILTER FABRIC SHALL BE A MINIMUM OF 36" IN WIDTH AND SHALL BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE ENGINEER 3. STEEL POST SHALL BE 5' 0" IN HEIGHT AND BE OF SELF FASTENER ANGLE STEEL TYPE STEEL POST GROUND LINE N O a w RE 6" FILTER FABRIC FILL SLOPE //��//�� L- FABRCRSKIRTR GUIDELINES FOR TEMPORARY SILT FENCE DETAIL NOT TO SCALE NOTE: TREES TO BE SAVED WILL BE CLEARLY MARKED PRIOR TO CONSTRUCTION AND A PROTECTIVE BARRIER IS TO BE INSTALLED AT THE DRIPUNE. DRIP LINE - THE AREA OF SOIL DIRECTLY BENEATH THE TREE EXTENDING OUT TO THE TIPS OF THE OUTERMOST BRANCHES. METHOD OF TREE PROTECTION DURING CONSTRUCTION NOT TO SCALE GALVANIZED BAR GRATING 1" x 1/8" BEARING BARS. FASTEN WITH J-CLIPS, ATTACH TO A 1 1/4" x 1 1/4" x 114" GALVANIZED ANGLE FRAME. MORTOR FRAME TO TOP OF OUTLET STRUCTURE �REINF076CONCRETE BOX L POOL EL. = 6.00 I / (1) 18" CULVERT i / I I / � I � y �6„ 6" EXTENDED f-6' X 6' (APPROX.)- ) BASE 3• / POND OUTLET STRUCTURE SECTION NOT TO SCALE OUTLET PIPE (1)18" RCP (CL.111) INV. UP = 5.5 INV. DOWN = 5.5 SLOPE =0.0% if IE z O 1 W L` N O � O rTPI w��1 w O �1.4./� 2 F� of Cn O LL Z O z W J U z W" ow M N N � n�N O Ilrr� 2� Von 0 rc A OO Q wU..az� c°�i wz o� 2O0�2 z 3� w W Ua UU ohu. a F 3 :3,: F Z o= O H Q � F 55 i 'S � 0 (jg rco I- z 0 L Z C7 Z_ F uro W so N pppWii Q2 Y 1811,100 0 i29 W IL Vau.K LL'2 0 SEAL ,' O .'''Ess.fro.,�i2 - OT�C'iNE�''�PJ. C-5*1 PEI JOBM 12293.PE NOTES; z NOTE: om aM2 of aDe eP1, AND GENEOL USECLASS B CONCRE E TiWD D q r. 1oco < X PAWIN ALL GTCN SASINS BFEN S'-G' IN MPTM WIN STEPS 12- ~ � 1. STRUCTURAL DESIGN OF END SECTION SHALL CONFORM z �a4 „ X r, 1 , woo w ON LEXTNR. IRE BIEPS MUCH COUPLY WIN SIC. DRAWING BE0.08. F X WITH THAT OF STANDARD REINFORCED CONCRETE. r'mw OPTIONAL CONSTRUCTION - MONOLITHIC POOR, 2" WMY, ON H W OOMEW AT �. m0 X-4 7 :, ;.. r : :. r :;. yy 12- CENTERS AS DIROM BY THE ENGINEER. W MZ-I eee-xfff> Y n. A Y L - IRE FOMB FOR TIE W6IRCRGM OF THE BOTTOM SLAB. 000 m Ld ION a>. , m.. -- - a ":° IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM STAB OF RDA, AM TO WkS W Q LL= Q W PIPE WALL UNIT zxiocO B UKAS HOWNrm ON M. NO. -W 0 Q o" '? _ _ _ _ B• .y'e S• x If°E 7YPE "E'. •F° N1D 'B' (RATES uILE88 OTMEBRSF INOIGIFD. hx Z W o DIAMETER THICKNESS SLOPE B C D E WEIGHT opm'r" o P4R e'-o IN HEIGHT GR LESS USE e• FALLS AND NOTION BNB. OPEN w=0 ,yZ , e.: '. ::..°... S-NY' TO 16'-0" IN HEIGHT ONE B. NRLLB AND BOTTOM °LAB. ABIIRT 00y� DD MMRTIE° ACCORDINGLY. 12 2 1/4 3:1 24 49 73 24 730 --1 CONSTROUT WITH PIPE GONR MTGHINB. zF> 15 2 1 /4 3:1 27 46 73 30 910 yz PLAN x.. - :.be BEE Mum OFNFER ALL E POSED CORER 11. 00 TOP ELEYATIOM SECTION X-X oRAWINO x2r TO smu. 18 1 2 1/2 3:1 1 27 46 1 73 36 1 1190 21 2 3/4 3:1 36 37 73 42 1370 . u .aB srEPs - sD. No. B4a.Bs PLAN 24 3 3:1 42 31 1/2 73 1/2 48 1770 27 3 1 /4 3:1 48 25 1/2 73 1/2 54 2130 O z TOP ELEYATI D cc -- E -I A ,L o z C B 30 3 1/2 3:1 54 19 3/4 73 3/4 60 2380 ro_ r j E -1 B :� x ° G B 'z' m a p 33 3 3/4 3:1 60 36 96 66 3870 ; •ml N 1 SECTION Y-Y B :'v: °+. °� 36 4 3:1 63 34 3/4 97 3/4 72 5320 IR D ? D o Cs > C O O LU nim NE. � to °� ¢ � � + 42 4 1/2 3:1 63 35 98 78 5920 �' a �+I A t9,1 O _ - s• ": y''.;.'".. 'r, p O ¢ DIMENSIONS AND WEIGHTS: NOMINAL DIAMETER AND MINIMUM ZZ WEIGHTS FOR ALL CHAIN LINK POSTS, FRAMES AND GATES SHALL w SLOPE lI 48 5 3:1 72 26 98 84 7470 -p o SECTION J-J da'r.:?:_^':>- < W 2 < Fw y 1- F• BE IN ACCORDANCE WITH THE FOLLOWING TABLE: a F-1' ° ''> NHmE 70' TO 8B' PIPE 18 U9E0 r :.::. m W _ a 54 5 1 /2 2.4:1 66 34 100 90 8810 � .: eEE 1 SECTION r-r RIP RAP m O mum �• TO °*• KPE IN USED x � � OUTSIDE DIAMETER MINIMUM WT. PER FOOT G1 > z MERE S0' TO NO- PIPE m USED .mi ti USE AND SECTION 0 60 6 2:1 60 39 99 96 11180 Oo aismf. Z N NOMINAL LBS. (� N r vAWIEB ' - END CORNER AND PULL POST R-n . 7 2:1 7$ 21 99 10$ 1398D Z O _ _ _ _ _ _ _ J P'9 T J Z V UBULAR FABRIC HEIGHTS. 6'0' 2.375 3.65 l N O O O O O O ;0 B r _ AND LESS: ROUND Ono 000000 )0Ono O DIMENSIONS IN INCHES WEIGHTS IN POUNDS e. OVER 6'0": ROUND 2.875 5.79 Z SEE SHEET 2 OF 2 SCOUR PROTECTION °.y ° INTERMEDIATE POST FOR FABRIC 190 272 LO FOR DIMENSION TABLE NNERE 42• TO Be PIPE IB uBm ?;- - HEIGHTS (TUBULAR) 6'0-AND LESS 1� �FY r'.,. -J aaJJ 2D' U 1 OF 2 SOP NY ESR R NY ( P� PLAN s1EEr T of z Fes, u 84D.02 ��"0211 OVERB'0" 2.375 3.65 1-� SECTION X-X RAILS AND POST BRACES 1.66 1.36 O H d GATE POSTS FOR NOMINAL WIDTH FT'1 W OF GATE SINGLE OR ONE LEAF OF 2.875 5.79 W, hM+l DOUBLE GATE WIDTH 6'0. OR LESS: 4 ROUND h4 FLARED END SECTION - OUTLET 13WORLESS: ROUND 4.00 9.10 n ,r u m B L 6 6" 'Wi 6" zo F- /•�� NOT TO SCALE H N-1 Y 13'0" TO IWO': ROUND 6.625 18.97 F+y yy 1<R' z - z 1 " CLfl. TYP. - z QaQ3 D40 WI = #4 REBARS TD e. #4 REBARS ZIro OVER 18'-0" 6.825 24.70 O C'n ro,n cc -_---- LLN"F0U' GATE FRAMES 6'0"ORLESS IN a mz xy pp�=z HEIGHT 8YY OR LESS IN WIDTH: 1.660 1.806Nt ? =mZnm THE PATTERN OF THE ^:'o' . uI.jUw r ROUND Z C3 ZZ xm�p I Iv aD I I. io KNOLL -OUT °'`•'". Q r 10. GATE FRAMES OVER 6'0' IN HEIGHT W m Oy Z,y'OrT I I . ,,., I " I ,-r ." :o.' . Fx ZW 1.90 2.72 -1 O y "+�. n, O Ny :. 1 3n 1¢3 I PANELS ARE SHOWN ' °. : " .. v m t-- LL O J OVER 8'0' IN WIDTH: ROUND () <; 4 43" NOTE: USE TYPE "E•. "F' AND 'G" GRATE < O DD I 6 I I ` ¢d FOR ILLUSTRATIVE ¢ O y q¢ t. a P P f,. "'R'zD I N : > I I > PURPOSES ONLY. " : n ` ° UNLESS OTHERWISE NOTES. •� > n .v. • - ' .v ° .' - t N P200 '".,( nE�R70 ,�-i 3n I n N 3 I�> Qvm�� r� ° LLJCO~ m� ' q5 REBARS 12 ) ( gSnREBARS .:. °, :u:.. -.o ;e:.o,::: p .o D•in Pm-1oyC=A s = WmLLx' z CE_N_TERS jTYP.a .. 12 CENTER °: ° :'°'. S . . A'. °.' o . �'.o,'°`.. S `. .:t , Wp V 1 1 M,s" E-00 .e a- _:- _ V ':o•.' °'. ° ,%y -�1 Fes"- Q F N'-' .'v' :: v •..o' v ':. v •. z„xo14� "NSIDE N N mh¢U.$ ::SECTION 'A -A' iO SECTION 'B-B' iO ° P. °''.o- °- "_ p.. ,.t. 01 : 29 1/4 CNiE61UM- LL sopTxom _ BM po',rr_n= D .. ''� .. l z Fl A o A ALIGN FRAME , 1$" g.�, B °'' ' : NOTE: _ roa y TlciON eco.. t" YINNO WAFFLE BOXES WILL BE ALLOWED IN HTE CITY RIGHT-OF-WAY C yz `AI m cLR.(TYP) OR EASEMENTS UNDER ANY CIRCUMSTANCES. ALL STRUCTURES Ir d- rraleN - Y TT p o A #4•R BARS A C 1" YIN. j C LINDERTRAFFIC SHALL BETRAFFIC BEARING. THIS INCLUDES LL V ��0 O ti N B SECTION . w SECTION . NN -rl cc 1 y 4 i!+ ° CLR (N 4x4 W4xW4 DRAINAGE STRUCTURES IN PARKING AREAS AND DRIVEWAYS. W Z Q 4 O O ; Z U o U ,-I x WWF (LAP #5 REBARS 0 12 '-' F 3 c O O m iZ W#F 6 ON CENTERS (HORIZ. 3 07 _ AZI y T m FRAE,GRATE, IL HOW ASS'Y a * O Z ✓A t (USE WITH �\ pQ W LL. m c �- 22 24 29 1/4 N 00 a c r1aN J I ¢ G .za y -1 = TO KEBABS) 6 VERT.) 2 -1 29 1 /4 > 0 z 23 3/4 y\�' W Q WI _I LL O 3 0 1*I t3 0 4' X 4' a LARGER p 0 LL z 0 C-= Sn / W 'pO Z., " y w _ o B e : ': °' DRAINAGE STRUCTURES a : S .. , .-. . qq O mPC - -4a"i o n ,Lr 6" D TYPICAL) :o. O N p vi C� 0 1 5/16 . ai O U zw D@ _ _ _ ' Im- WAFFLE WALL PLAN VIEW SOLID WALL PLAN VIEW ': :. z O DD Z yy m O a ':." o":. -R Zp N -K a _ _ 144* t *• m N 8° L` 6° 6" 6" >9 L M r 'A O :..A; . ° .:..o. oA . °:.:..o °:.:..,°'. 1m-N ~ O USF 4190 4623 9 M p NY{i10N M ---+- Z 0 '" n• 1" YIN. CLfl. 1„ MIN. CIR. ?' ` :o .' °' ` ':o'.' °' ':o'.' P. `'.u•.' ?' G7 a Z v O� _ t ` H p 4x4 W4xW4 0 - .:,v'.:;?' :..?,:: 'o' o',::'?' o'.:b :r, o',:;. Z 2� 3 4 NOTES: o L F'ti mO.m C 9 ° W o WWF (LAP �_�o;'° O'o.a.0.o.e.°,'-•o:n`.0;0,:>: W W / A W D D 4x4 W4XW4 J WWF 8" Of > o, o... °. ::... ° v ... o. v o. W np I J ) aWOrsor - al m w9 m WWF (LAP WWF m TO REBARS) o':: ;v :.-a':;o :.-v':'o• :..o' ::F :.o ':. d 1 1/2 x Zp ,- " " 1,.1 W W 8" ONTO REBARS) ° ¢P < . e,•o'?•. °.'.o.•" ' °'-o.•"-' 0'0.'•'"- 16 3/4 1- MATERIAL: ASTM-A48 = 64s O m a BS > 05 RE,. <':: ': ,. <'::.:' ,. < ::: -- CLASS 356 GRAY IRON. O m >ELMS R e" R I #5 KEBABS 12" r p' :. o :, o' :.. o :: o' 2- FRAME WT. 125 LBS. APP. "1P -_ _.-- _ W ¢ ° 12 CENTERS e: �.o .:.'. '.°..:... E-T p 9 t = t W O CENTERS (TYP.) TYPICAL ¢ 3- GRATE WT. 115 LBS. APP. °e z { g t• " S a :o.::>..;-.:., .:.,.,: <,.: �- L`' U.S. FOUNDRY & MFG. CORP. " a T41L•" - Ems' 2 ' I SECTION 'D-D' ro SOLID WALL ISOMETRIC VIEW BHT' IF 2 22 �1 840.45 SECTION C-C a 840.45 MEDLEY, FLORIDA SECTION -IOC tY'-11 " 24 CERTIFICATION NOTE: USF 4190 FRAME & 5259 GRATE t DF 2 coos �rAt><oll SECTYON - n 8 T I t" a OF 2 CONTRACTOR SHALL PROVIDE CERTIFICATION FROM A LICENSED 29 1 /4 "" °' DBBSM 1 8'�=1' M. 3/9/98 $40"03 NORTH CAROLINA STRUCTURAL ENGINEER THAT PRECAST STRUCTURES PROVIDED MEET REQUIREMENTS FOR H2O LOADING A4030 �' ® rT, W O o GENERAL NOTES: z r l O-mO OPENING SHALL BE •L' OR 'IN' + 1'-0" �y * THIS PRECAST ROX MAY BE USED FOR THE FOLLOWING TED AS REWIRED i HQ 0 z STANDARDS: 840.01, 840.02, 840.04, 840.05, _ 0 m „ FO•, rn o-mi T (A 840.12, 840.14, 840.15, 840.17, 840.18, 8408409; 11 . •�'�, c g°" REBARS a" ,Qz., I¢,ry V 1--, rj ICJ F-{ DETAIL SHOWING TYPES OF GRATES 7-t144" 294 QQ mzyxy 840.26, 840.27, 840.28, 840.31, 840.32 AND 840.41. D a ' - ' ;° - u. �w. o USE ACCORDING TO WATER FLOW. 11 � aF- 0 .n0 0-4 * INSTALL PRECAST DRAINAGE STRUCTURES AND PAY � � • � � � � W4zU- P�1 W O 1 N mmco B F-50 x-N DDm r- #6 BONS Q x !�•i mo ;2-4 LL-�a"'z 9 FOR IN ACCORDANCE WITH SPECIFICATION SECTION 840. I @ OPENING QO �ON°OI zFEM T =T OG TYPE "8" TYPE •E" TYPE "F" rA A 1n} I 8 „ IW-c� LLox m rd * DO NOT PLACE PRECAST DRAINAGE STRUCTURES i STEPS ' / �Fx-Ry zOJ O P+$r SECTION C-C x�co IIIfluFxr W if D� * LARDER TRAFFIC OR WHERE TRAFFIC WILL BE DETOURED. C eaRa .� Z USE 4000 PSI CONCRETE. @ OPENING C _ Z Coo • �„yy * PROVIDE ALL REINFORCING STEEL WHICH MEETS A$TY A615 FOR .,, yNy 41 1/2---.-1 vJ I 93YG z .� co WATER FLOW SAG -*- WATER FLOW GRADE 80 /COD WELDED WIRE FABRIC CONFORMING TO ASTM AlA185. ___________ ap LIMIT YAXIYIRI DEPTH TO TOP OF BOTTOM SLAB FOR WAFFLE WALL - '�'^��0�':<:'�'?. e" MIN°: °D---------------------------------- p STRUCTURE TO 10'-0"; LIMIT SOLID WALL STRUCTURE z S TO 15._0n D :....°. .,,.°. D� U �ON 4 9 - � * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH e" 'V B" .�<',y o_.e., T 4 �( i 1*2" 4'8' '9 OSHA STANDARD 1926.704. v :,='. e, , e �I PLAN TOP SLAB :...:<: W ?9 1/2 NUMBER 23 3/4 24 O ! ""1 �1 11i „/ O SECTION B-8 ,'a * CUT OR FORM OPENINGS FOR PIPE TO PROVIDE .'_.`. .. r'::'� O'. 1J•i W m m REQUIRED SIZE AND LOCATION. ORIENT WAFFLE WALL STRUCTURES F-:!:.:•'E ;o• _ oo� 29 /f2 -n - - - - - - - - -- - - - -' 1 " 2Ti4" z O A z SO THAT PIPES ENTER THROUGH THE 0 1- 00 Q� f/11 w o -WATER FLOW an ITT 8A6 WATER FLOW -•- o O Q z y KNOCKOUT/WAFFLE PANELS ONLY. PIPES MAY ENTER THROUGH v .J.1 OO O �O P. � Zj 1- SECTION A-w W O DG m -4 m THE CORNERS OF SOLID WALL BOXES IF A MINIMUM OF 8" OF CORNER CUT DETAIL z � Q H x (SOLID WALL BOX) z r �• m m q i v O WALL IS PROVIDED ABOVE THE HOLE. ; p m LL LL 0. x " n " " ro n TYPE _ E C ►- CO * ALL ELEMENTS PRECAST TO MEET ASTN C913. Q PE F TYPE E TYPE G ; Z Q `� -1 6" •L' OR 'W' e" ¢ L7 z ROT m 1 S p ?w * FRAME AND GRATE HEIGHT MAY BE ADJUSTED WITH CONCRETE p W Zp Z O -4 RAISED FLOW ARROW p -1 m O OR BRICK IN ACCORDANCE WITH STANDARD 840.26. #4 REBARS _ t'S a O -4 Z P 31B" HIGH �3a w O m * r_ n 1" CLR 0' @" CENTERS oT p¢ a 13; o rr t" O lO °� m �O PROVIDE PRECAST STRUCTURES OVER 4 0 IN DEPTH WITH : .r.e o Q m 1 i/$ F- RAISED FLgY ARROW 244 ¢ #4 REBARS i.P W Q O m > %(a" HIGH -� r �% Q W z O STEPS AS DIRECTED BY THE ENGINEER. 1" B" CENTERS 7.!' a p N t- 9 I/ 2Z g US o O v p ~ r O M O * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG CLR . Q Q Z NOTES:. � AS THE SAME AREA OF STEEL IS PROVIDED. y tY 4 1- MATERIAL_ ASTV-A4q H y 1 i4t" Tp 43' O to ' - .... G J CLA_ $S 309 GRAY IRgy. Q 5 0 z O �E 1y2" z m -1 H * SEAL JOINTS WITH A FLEXIBLE BUTYL RUBBER Q FRAME W O O LL Ix PRECAST RISER PLAN PRECAST RISER DETAIL x ¢ 2- FR WT: 165 LBS APP. A.,/ I » 8 z O .+ ° " x O y c BASE CONFORMING TO FEDERAL SPECIFICATION SS-8-21A, H H w 3a 3- GRATE vjll 210 l65 APP. Fii g g .. x P O 1q6" .¢.I W P+ co AASHTO M-198, TYPE B - BUTYL RUBBER. J rn W I- �> z a U' m O O JII m..,1O * LIMIT NAXIYlX1 STflUCTURE SIZE TO INSIDE CLEAR:e._ :-;e..:. e. Z v V' U FOVN��ii N �j WN2" r: a_ww wo11'¢"fl W ¢ v C S DIMENSIONS OF 5'-0" X 5'-0". "9 "Oe' °';- "°' '`F''� W W '101tlD'L w o DQI z z a n ro ILO ' Q. 41 1 2 J ug I" w 3 G ' 13$-"��"- N LL� * THE OUTSIDE PIPE DIAMETER PLUS 2" OR THE OPENING O U - O R7 REQUIRED FOR FRAME AND GRATE IS THE MINIMUM STRUCTURE 0. U3'' 4139 fRAft1E dt 6429 GRATE d rc _ uj ¢ O w 13 x z 2'-71$4" 2 11 �4 l a. z w m w rt"" 1* 6n 6, , a LL 4 CI W O C U -►{ -L _ ___,� rL -`i SIZE MANHOLE IS E ANEATER. CS 1"-i - 2 03 92 USE MANHOLE FRAME AND COVER AS INDICATED ON THE PLANS. g 1% SECTION A -A � � Ty" REINFORCE OPENING AS SHOWN ON THIS SHEET. SECTION VIEW SECTION VIEW I SEAL Er z of 2 TYPE - F rnE G a SECTION A -A axEEr z t1F z SHEET 2 OF 2 OPTIONAL JOINT DETAILS sxEEr 2 of z H ,.�'';C�` CA/�O 840.03 840.03 840.45 840.45 DROP INLET DETAIL DROP INLET FRAME & GRATE DETAILS LT NOT TO SCALE `•� NOT TO SCALE W %O c CL\N�` C-5*2 w PEI JOB#: 12293.PE 1 vto �tD om SOLID COVER SHORN PERFORATED. PERFORATED AVAILABLE c m GENERAL NOTES' z w� E"IT H'rt IF SPECIFIED. HEEJ Cy s <. E 43° NOTE: USE TYPE "E", "F' AND 000 GRATE SS.A 64z ya �y STATE USE OF SYSTEM ON COVER �� <.1 I`r.. THIS PRECAST BOX MAY BE USED FOR THE FOLLOWING STANDARDS: ow y0� IN.ESS OTHERWISE NOTED. •`� P. P gz Cj woo (I.E.: SEWER. STORY DRAIN ELECTRICAL) �� - L-� 1 �< Q H z '•' 840.04, 840.05, 840.14, 640.15, 840.31, 840.32, $40.34, ~'Q p H s , ' ¢ o 'aymoo @" @" eao.ss, 840.38 AND B+o.4r. I- o�E4W( LLJ w r0•nym H C9 r. H.NSW 1' YIN. K C1 ma i s OOD'xa ma x-1 Q U.Jdwz m0 -ly CLR.(TYP) INSTALL AND PAY FOR PRECAST OHAINApE STRUC7URFB IN ACCORONNCE H IC , Q y D B w "'• y D ,t;• TOP OF COVER 000)x Hz_4 SECTION VIEWS WITH NCODT STANDARD SPECIFICATION SECTION 840. LL-EyHa Wg Ems= =0 m W6=LL G) y 1" YIN. • USE 4000 PSI MINIMUM COMPRESSIVE STRENGTH CONCRETE. O�Nx �Etz?y y • <E� oo - 'E 4p I.-c��oo x-N 'E^ CE"•m'P) :; OPTIONAL JOINT DETAILS • USE ASTY A815 GRADE BO REINFORCING STEEL. USE ARTY A185 wa Mom= z"x,.•M�•W - N N �i`~�W zxMo'" lA A B B a Ems- "J•• x 00 4x4 N4xW4 YIELDED WIRE fA&iIC (NNE). M-'0 000 fJ �z s _ 8Cf•.ITY - LL iBCFiY - Y O' O SZ WZa-• a0D„ym MF (LAP) a5 TERS (@ 12'IZ. LIMIT MAXIMUM DEPTH TO TOP OF BOTTOM SLAB TO OSHA S- F-Of-N yM YY 00 DD ZO fl 0= a MMF 6" ON- CENTERS (NORIZ. • PLACE LIFT HOLES DEPTH PINS IN F ACCORDANCE S WITH OSMq STANDARD N�My- <� o A A ALIGM FRME WITH INSIDE d OF 1WM.L 70 ALLOW M L _ _ -_ _ _ _ _ _ _ - _ _ _) L _ _ _, „ D TO FABRIC USE WITH - ORIENT STRUCTURES 80 THAT CORNERS WILL a O _ 1 w < I- •i ( NOT BE CUT OR MODIFIED OMz • FOR VERTICAL ADJU87LWT :.: �`I ' 00 w2 a WO w0 ' DRAINAGE STRUCTURES " PRECAST ALLOWED BY EL LEMENTS TOLIN MEETPAGIN C@13. aC Sl-'JL� V-8" LEGS OR BRIO( IN ACCORDANCE WITH STANDARD 840.25. WALL 8FCTU M :°:" e ' k 1•g" R. - • ... TYPICAL) - 'L' BARS WITH a FRAMEAND PRECAST TE HEI STRUCTURES OVER OGHTMAYBE USTED N DEPTH WWITH ITH O O O 2 n ". _ STiC'IIY _ Y BOTTOM OF COVER" PLAN VIEW OF BASE UNIT 8 SECTION - PP SECTION - Y 1" R. STEPS 12. ON CENTERS IN ACCORDANCE WITH BID. NO. 840.66. 8' 'L' OR W 8" • WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REGAN IF YIN. YIN. THE SAYE YIN. AREA OF STEEL IS PROVIDED. PLAN OF COVER • SEAL JOINTS WITH AN APPROVED SEALANT (SEE SECTION 640 OF NCDOT m LLRY � c z STANDARD SPECIFICATIONS. 8" CENTERS TO 8'-0" x W-0". w M FRAYE,GRATE• M IMXD ASSY O z LL > m 54 CENMS @ THE OUTSIDE PIPE DIAMETER PLUS 2" IS THE YININIAI STRUCTURE O •R a L,. DC w �i m '°•) 94 REBMS @ " LIMIT MAXIMUM STRUCTURE SIZE INSIDE CLEAR DIMENSION f- 02 r n _� I EO LL O az Q PLAN OF FRAME LL e B" CENTERS Ea:H wAr .' • �is o y t`/j M M ' . G` Lu z O yH 1'•111¢" z rS .A flH LOCATEDINIS GREATER. OPENIND REQUIRED FOR GRATE AND FRAME WHICHEVER fl V �" O om x w C OrFS r x I I M I i x CENTER THIRD TYPICAL PRECAST M ROIRMI MANHOLE WY BE USED IN LIEU OF SQUARE PROVIDED 2 EXTRA !D 3 Ci S518 ARE PLACED ON EVERY SIDE NOT ADJACENT TO A WALL. SEE STD. 3 d z +D W - t ' is fll y 2 1 I y . _ _ OF WALL RISER SECTION oND, e4D.ss FOR MAWDLE INSTALLATION. 0 w m$ L r = �- 0 1'-1oiR" I m g PRECAST RISER PLAN N 1�- M --E s Fl! _ EACH IDE fA C� wyy lECIFdI M I ' I Z F D O iw / \ TYPE Y7 I' -�{ T g LL z O OF OPENING FRLLLSSPNI Bn 'L• Ou ZOit W D `t L M R^"'RWn <fl O SO z \I �3�ff �I 1+� ° .-I C fit �0 7" Yix. CLEAR MIN. YIN. F m Q fy'f Ri w J FRAE PLAIT RiCIIY - UJ ax0 °' 2 01 = " W -4 'O "z•I r - n = Z . w W O fl �� 1 ' �� C 9 2 I 'L' OR W' 4 2 WALLS 1 YIN. CLR. x N M O . x X Q •T1 -"j �,� 1t1JJJ��� - ttJJ��,, � J ED O J ALTERNATE 1`•t0Y$ O = m iR ' STEPS 4x4 W4xYT4 '+t o N 4• C� O C �"�I`�- "'if _ R S" R = = LI O ~ /� \ z a O ' 8" CENTERS - ° J o •c'• op. (L Q w O a - -.- - - W W Q 9 m �I \ _ _ SECTION B-B w O y - o : ' • . i- 6: MANE (LAP WRAF m o • o• :.P• z aa W g c s O \ / 1 e 6 ONTO FABRIC) f -- p:... p w d N n MINIMUM WEIGHTS - 193. - • 'p• 'a F `./ 3N1 1 3'-0" " I w>z 1 • O144%- 2' G ,I \ COVER - 120 L _ _ _ _ _ _ _ _ _ _' OPENING 1•@ ' 85 RESMS 12n 0 .: v' � ::p' ; p '°- o• all, O I CLEAR (SEE NOTES) CENTERS 0 •. SECTION A -A TOTAL - 300 'o'.• • 'o-- ° .' [ h�gL.1( SECTION - qI "4'-14 " 96 „ 1 / LOCATE OPENING _ si .. V,:: :.•. :: P' F'.:; n o. v • P• o [--� \ / SPECIFICATION As REWIRED o a TYPICAL SECTION ..: o. :o..o ....' \ / CLASS 30 IRON MEETING ( SORES) TOP SLAB 2• = W W V 1 GF 2 = sour Y Y t of z Er , of , �_ _ DIEET , of , Er i OF , 6" L' 6" TYPICAL SECTION m: 840,03 840.03 84C TYPE 0z ASIA A_48 84d.54 840.46 "' PLAN TOP SLAB YIN' OF BASE UNIT ISOMETRIC VIEW 8 T I F I MOM W w a � ate Roil E z o r 1 WM ain • ""Y H� A OPTIONAL HANDLE My am , ON .2104 2'-1144" 244' f <y a" e• <r I<-•�z R«t ' , n HQ Fi1"1 i' DETAIL SHOWING TYPES OF GRATES < H' E < I •� -6 �woo9 USE ACCORDING TO WATER FLOW. 1 � �Qco Ho a1NDUL wErw: Ia�e�sei ZDmoo 1' DEPRESSION 'r ,. r -D w B o 71 w Y H r, - Hm9N tYS �{r+-1�8' �xx3� LL l� 0 o y mFEMI wA T LL ¢ H _ o s• - _ USE CLA S ' ' CONC9 aReNRs t". � o �'(' � �` I I I "+ C9 Z H -1 D LL a m0 USE 12Ii8B •8• CONCRETE! TINDIBIOIR. LLJww HOy-OD r x r u ' I H 'LO JOa Sz mz x-E ooy)x I„zy > I L Ooaxz mz x-I 1 -74'g t -74fi ,i.. F� o O O O a n x x . n W LL O O TYPE 0 TYPE E TYPE F rA r. 3 = = EW - x x m - Z 14 7 I 97�8 M-ogo 7T s X X oPriaNAt wrDTWDTzoN - NaMDI.ITxic Pace z• xEVNAv w w LL flo 0-4 ' ' tDrA o r o . p -r m TxE TBIi4WFFA. <OOp - -'MUS - -G- G E , E HUO�HO�T �Ix- O W ax'wOO� -- - 'T - • o n ✓' .� N1 I ENE POW TO CONSTRUCT THE BOTTON sue. i--x aE-1 =MOM N o_ i _ +` Q W O D y :- I !mmum/IIBr8" 20Ic ;� O yZ -- I,I. u ADD TOIF "FORIM CONCRETEB AD MMON'ST NO. $44.00. OF aOx. w0�Mg p0v � Nr__ _S �OUONQ U H 1om Sam JUST'_ 0� • D � WATER FLOW --+• SAG �- WATER FLOW ^ O W� • _- i WG �0 •+. .'1 m �_ 4-�"'� 1PP1'ON CENIER92MIACWDNYE WITH -8!D NO. sw.be. OEPIHI WITH el�b zdoH z t-1 Off - W Z B tYe" fl z G' ;�� a" ~ ADJUST THE STEa, COMEM AND BRIDE MGMAY MASMIE9 0 SECTION G-G 1 d0 r T 1 z Y BEE STAMONID 6M0.5{ C TOTO INCLUDE AADDITION IaP ION OF mPENRIQ E JZ.F.a IU vMIABARS n\ O TLy�l ' _• PLAN a� MWA am9M a FRNW ra ''A• MEI6HT MI ONSM. aC-NINa IN TOP a m.) :- I'-41'Q" 1'-412 � F .. - - - - - - - - - - - - - - - - - - - - - - - - I PLAN OF FRAME BRICK wr BE IBM C. 70 G. EMA ON 18 1s FEET81WD1WE FA011 TOP OF BORW SLAB TO TM 10 W M SECTION B-B To ABRYT FA NE a 7'-73'y" 1'- " CAST IRON Z O ��C) To 7�4 21ii" L G w m. ¢ EEVATiaM NAx i DO :o RO a N t` a Z -►WATER FLOW SAG f- WATER FLOW o O E� e� z ac Oc o m PLAN OF GRATING CO �? a S m z u- arrLET PIPE D0. O .. M3i O 2'-31/4" CAST IRON LL 2 d 0�0 SECTION A -A ��" �. w -4 M _ H j� T+N O PE F TYPE li TYPE G TYPE - E 3 z Q N x m - .. `I c I 3 0 2 ta-M -fll �" J yy O mm 2 . n n n n n wa0 -•19 x I � EOMF 17" }� Mz0 W r 2 Z mod' Z N Rt��U z wy 1 DC < fl - o -I-I IN PIPE ..� _ SECTION °'f-i ¢ My 4� a o -1 yb" ygn yb' „ ¢ a - tr, • U v*k w RAISED FLOW ARROW m e• '100 D > �z ! "HIGH 2 c fl w -�i Az C-C OR DOD DOWEL o z - ,� pL x�` �` 0 CD w tC Q y� z -1 RAISED FLOW AAflOW 2�4� r" 6 N p SECTION X-X ¢ "z'' O n x 7 1 3'-3 II•'•-t,I t 2,-3ln o W v OO a�i D y l�jB" HIGH _ �.{V7}�' y z O DEMM a AND NMKISTIu M GONM M JIN MKao p 7 ¢ o �-I 2 , ITd CJ q '�"' (� u wooL <0 9GO t--10 DIIN3IBTONBaMNOt AMO PIPE MNFaRCBFATI TOP WAB � 7� 61sn 1�x W.tINlBias COMIC WAND TOTAL M GLASSa ONUIOOM Fag dE W d Ix- 00 O 'B >C rO rr z W 0 -PIPE 8PN1 QDIN 11EI@fT BVIB •A• IN BOOM BMf NN WABa Pf1E a.n16. T- O A I u I - I I - a 2re z aE tom „ - x o "' x z "• EXr. ao=or D A 9 x xo. LENBM E F TOP wrmME auLJ Las. a. vas. C.B. R.C. ai W x a PF-I SECTION H-H `E - •, " m ~ (C)p O,ten " W H Iv 0 07 z eLM SLAB Fr.Mrt. REINF Nm. •N• I~ -I A O z 3'-2" I� �-2 I t W �-ay8 J m fl I2• 2'-e z'-o• 2'-s• 12 W-9• W-0• W-o• o.t® o.Iar .204 22 o.Tw o.mb o.az4 J z 3 1 RI fl _J z = l� w - '. ls• z'-s• z•-a• z'-B° lz s'-9• s•-s' s'-s° o.l9e ones o.zw 24 a.eoz o.oxB o.ase -J M F- (% R� 11*2"R. „ w W ¢O %� y 8• "' . /a" z.a• z'.a• z'-9• a a•_a' , v.a• a'.a• o.al o.za o.zrt a9 t.am o.asa o.ow W ii O y 21'R' q� I -i� 21t" '-- �y� , �{-� z y 3 z 2'-tt`34" 7 +I 2'-11 �9n LL - 20 a'-w a'-01 W' S- 18 W' V W-0• 4•-O• 0.m 04" 0.aw 10 1.4M 0.ow O.ow 0 m �.')'-7� �4_�_" �J co N 2'-7'4" M N W O W Z W. V-SO 5'-8' 3'-9' ,8 4'-9• 4'-1' V-S' 0.376 0.876 0.M 51 1.SBO 0.092 GAV H 1 Q = W 71'� 1 ttax " try' ab" 4'-0' 4'-w W-8• w 4'-B' 61-0" 61-e O.4aa 0.4W O.a39 " 2.341 SAM 0.178 7 n 42' a-6" 4'-a• 4.0• 22 W-a• W-e 5'-6• 0.50 D.Bm O.am n 2.aTe 0.160 o.zMa O1 3'-6x 2'-6" Ix t vq" SECTION A -A n 4S• 6'-4" 8'-4• W-9' M 6'-9' 6'-4" W_V 0.743 O.T43 0.40T 111 9.625 U.2a5 0.317 U. SECTION Y-Y s4 s-10 6'-10" W-9• 2B r-T• r-f9 r-1a s.eaa o.aeb o.444 +aa 4.2ea 0.2P o.4ot SECTION E-E SECTION F-F TYPE - F � SECTION A -A 81EET 2 OF 2 ET 7 OF 1 w•__ C-e' 6'-e^ C-S' eD ]'-e• r•e' r-r 1.042 1.0M2 0.481 146_ 5.om 0."Y 0.49S &MEET 1 OF 1 ET 1 OF 1 z OF z TYPES 840.03 64d•31 bc• r-+� r-1' r-a• ffi r-m• a•-1' a'-1• 1-210 1-a,, NZ fm a.9+T o.4w o.be9 SHEET / OF 1 84d.03 840.31 840.16 840.16 0 G OUT A1D BYWIML NOTES: 0 m z O -m0 GAME aF auM OBE «Ma 16• cOMOSETE 7WAO UT. Fy G oN -i PRMIOE ALL CATCH SAGIN6 OA31 W-8' IN D®RI WITH STEPS 1z QQ < S� EIPNBI0M1 JOINTS FY p<j• a X %. ON CENTER. = STEPS NOW COSPLY W11H CIO. OR M W.M. QF3 E-E• a 8• E , Q< �o Zz Sx 4•'B" D Iy109 OPTIONAL. CENTERS; AS DCTIOM - BONOLTTNIC UMA,M. Y 1MYMY, OR k 9M DENNIS AT wO00 r 8mwgcA "wo cif0 12' CENTER6 M DIREST® BY THE DNENFFA. W...1 H O •i B" 8' O Hz�Sy Y .> ., ::�p :• , e.:;> Y ` L _ INS P,BM FDA INS CdealRUl:TIa OF THE 9 MI SLAB. 0¢�yx Im4Zy xD Y4 BARS •V• 840; FAAYE 00�=2 x sd-4 • E' IF TEINFgN4D COIIGWIE PIPE IS SET IRA BKIMe SERA OF Bp%, A90 1b 6lM W Q LL O•pA y S•17¢' ' Q /1 om e.°'', :M.. --_ " M8110MOMST0. ID. s4o.ao. FO Op Mnz m I I- O vJ 9 �•. • •F' AM OGTES 19ME880RE W INDICATED. Q F "'I x000 I 1 \ < H x OM00 8' 'e e•x 116E TI'PE 'E'. Fx 2W z 'W o a H � - - - - r. Fall Y-O' IN MIGHT OR LESS USE 8" W ALB AND wTIOK SLAP. OV61 EO6 LL � C)) u" O 9 1 8'-0• TO 15'-0" IN HEIGHT m 9• WALLS A. BOTTOM BLAB. AIUUBT 00f0� O 9ZZ '!::.', '.•.c: !:" 1 •:; QUANTITIES ACCORDINGLY. z H yD R N a a' F.-Y.o• $ OM 7 �j PLANT 1 PLAN Di " .,.o :. CaMBTR1ICT WITH PIPE LAMBS WTCxINa. i-H �Myy ` m T m O E-H W p • X T SEE MOtE M'A1Ww AU. 004NED EDMNAB 1"• . GO EOOz LL ¢ CURB AND GUTTER WITH CATCH DVRIN ON STEEP GRADES • MM)C /-'� �J ,1-�) 7 a SECTION X-X WD m NOT TO SCALE. = .LAP 0 O 1"'1 1D Z TOP E EVATI I`1 ; USE OM FIAT A'E"' EXPANSION JOINT A ELEVATIOM !ANTES 24 AID INIOER + U W a x U \ GTEPS - atD. IRA. N1p.9a �J S ,- t_ l l OEPRESSw BUTTER LIME To - - - - - -- - - - - PLAN OF TOP SLAB SECTION S-S EXPAND JotKr ti m -v v Ili C. Z 1 0 e - 16 -r- LL z Cf Tzj ELEVATION O v J !yji/� fl �- v_, r A M O G) NMIAI CURB AND SUT O ON LIGHT GRADES W M ' /� )"-{ ( 1 Or S' R T `' E� oO %H OTA VV JJ `/ H �'� --I- _ (� w e :'a !': i':py..L�'8.r' T EMI Pa-t w n 0) z NORMAL SUTTEE LINE t W N '.0 e^ 6 e' Y d N '� EXPANSION JTOPOINT 04 an d x e' C .• 8" _ / a '' Ey - m N 8' j�E 98 •N" BRAS H BM H V J T�1 = m w SECTION Y-Y 9^;° \ 0 fl e a = m g O= d~!�-1� �- ZH ARIES C/� �° fl F" 'a C2 I � usE - - - fl i- v C l7 D "vISEN HT. 'S °: r '0 LINE �j /�\ ✓✓ LA D >, Q _ '° <... r Bi 0 w D 0 " EXPANSION JOINr io• 0_ L IY S A� 0 B 1'-0^ iM1 O 4, -1 0E _ 6 ''.:> :•:'.:, :_...:: 1 ELEVATION IW I- T j.4 n: •: T : ':: Q �4 Z e• : T SECTION J-J o ..:,.• :... w R- � y S 70 DOLL W S . r F rlr4eE so• m aC PIPE Is USES COW - H W NOT SECTION N-N SECTION N-R NORMAL CURB AND WI TER ON STEEP GRAM 07 M BIERE 4Y IQ as" PIPE 33 Uaw x �' N W M = Q N M D z W 0W 80' TO sb PIPE IS uew EO = co 0 NIMMUW nEtriaNa A D MNW 7ITII8 roN eo GaTE GTSN NA9Ix NA9w 9N MWY. IOJWIT N Lain No UI9w • Ffl4 z CA fl RISER . '.. .:. e, ..1 z i PIPE PIN WIDTH OF SOX AND PIPE HEIOMT DIIBWIOx BRAS BRIM N111B OM.YDB. CONC. tN BOM aFDIICTt -I 0 N '1 :... ..:. .. O SPIN RDlil F SOX SPA" HIM. -IF -v -M TOLL TOP BOTTOM M. EaN. Z O J r`'- • J .:: F.::.. ' F,::. F,::., s. N W y D A B C 4 N E F w w. SO. tA6. M.•8 MA8 C.N. R.G. W Z a i 70 - - - - - - _ - - -,.� R N ..._ s tz• a'-11 2'•2• .. ._ 2'-9• o.2aa o. C.N. o.026 ,1 •' +a• a••9• s-z" a•-0• -' '. .. o.mab o.oss 0.oa9 ' A A y < 'I /8' 9'-0^ Y Y Y-9' O.Paa 0.0ffi 0.049 O Q 24' 9'-0' 2-2' 9'-9' 0.2ffi 0.059 0. 1.00t OMS ' T ? m 90' a'-0° 2-2• --I 4'•8" 1'-2' 4'-0' 4 1'-6° 2 8'-B' a 9'-9' ffi 0.128 0.92i 1. 0.0ffi 0.12T N y .l 35' 8'-0° 2'-2' a'-f0' 4-9' 1'-8' 4'-0' I 1'-1," 8 8'-B' 8 S'-9^ N 0.151 0.859 1.7/4 0.1ffi OnTB OHM 4Y' TO SP PIPE IS IMBED \ °' �- y .;d'- 42• 5'-0" 20-2° 4•-S' 6 •8 t'-6' 8'-2' 4 Y-8' 2 z•-u' 8 r-11" ffi 0.112 O.a18 1.'!98 O./5D O.R49 ~ 5 W O p::.•:•.: P.::. a "'.':'e. •.::✓ :. 1/�, Q 2 L - - a• a'-D" 2•-2' s'-0' a-9 2•-0" V_r 4 r-a• s z'-n' a z•-n' ffi on4s o.affi 2. a.zaB o.a1T ^ LL Z DETAIL SNOWIMS RETHOD w' s•-o" z•-z• W.7 •a 2'-T' 3%2' + z'ao• a z'a1• a q-11• a o.tao o.a9e z. Y o.29r o.401 SHEET 1 OF z F RI R COYSIN{N:TI�1 PLAN ELM MEET 1 OF 2 EET 2 of 2 64d. d2 840.02 840.02 • RISER NAB _22B CUBIC YAFM OF CONCRETE PER FOOT HEIGHT 84d d2 :~I j }ggg V-' O Z g5..� Of zzW O o M fij _10 Yi d1.)0. x O Moo Lj W SEAL Aoplo�: .a Z-''�� •'FNGINE�e'•�UFa ,I. c 'A ?LI13 C - 5.3 PEI JOB#: 12293.PE STATE OF NORTH CAROLINA, Department of Environmental Quality, 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 (910) 796-7215 FILE ACCESS RECORD DEQSECTION:�tiGlYll �tU1TYyyJOtiG REVIEWTIME/DATE: ��� Vf U `? 1�L7\� NAME: ,�CCslt}' (`i('.Cltyys'ts�< EMAIL: REPRESENTING:' IA PHONE: Guidelines for Access: 'rhe staff of Wilmington Regional Office is dedicated to making public records in our custody readily available to the public for review and copying. We also have the responsibility to the public to safeguard these records and to carry out our day-to-day program obligations. Please read carefully the following guidelines signing the form: 1. Due to the large public demand for file access, we request that you call at least a day in advance to schedule an appointment to review the files. Appointments will be scheduled between 9:00am and 3:00pm. Viewing time ends at 4:45pn. Anyone arriving without an appointment may view the files to the extent that time and staff supervision is available. 2. You must specify files you want to review by facility name. The number of files that you may review at one time will be limited to five. 3. 4. You may snake copies of a file at $.05 per copy. First 100 copies at no charge. Payment may be made by check or money order at the reception desk. You may also scan to email or a thumb drive. 5. FILES MUST BE KEPT IN ORDER YOU FOUND THEM. Files may not be taken from the office. To remove, alter, deface, mutilate, or destroy material in one of these files is a misdemeanor for which you can be fired up to $500.00. No briefcases, large totes, etc. are permitted in the file review area. 6. You may take photos of large plans with your phone camera. Necessary large plan copies can be scheduled with Cameron. Weavernncdenr.gov 910-796-7265 for a later date/time at an offsite location at your expense. Requests for large plan copies should be attached on top of the file after completion of the review. Allways Graphics can be contacted to set up payment options. 7. Written questions may be left with this completed form and a staff member will be in contact with you IF you provide your contact information where indicated above. 8. In accordance with General Statue 25-3-512, a S25.00 processing fee will be charged and collected for checks on which payment has been refused. FACILITY NAME COUNTY 1. Sv S1'3 0 `a 12 ��- 2. sw x ) -s(z()- 3� 3. 4. 5. / Signature and Name of Firm/Business Date MM/DD/YY COPIES MADE PAID INVOICE G:/ADM/Shared/File Review Access Form r v 2022 iU'ou /J� ij� Time In Time Out