Loading...
HomeMy WebLinkAboutSW1221002_Plansheet CL501A3.P2 - Other_20230223 J \ I \ o ��� U LEGEND PROPERTY LINE BUILDING LINE Gresham Smith o � I m I W WATER LINE (SIZE VARIES) GS-NC P.C. LU cn J An Affiliate of Gresham Smith o — _ _ _ _ _ — SANITARY SEWER o�Q vvI - - - - - - - STORM SEWER Q J N QN�V N ; I UG-E UNDERGROUND ELECTRIC h 0 I o� I \ 201 South College St. v�' rn I \ G NATURAL GAS Suite 1950 I I vv N I v v Charlotte, NC 28244 / °o Z �' I 3 \\ — — — — — — — UTILITY EASEMENT LU 704.944.7970 Vo \ z I \ FIRE DEPARTMENT \ I \\ p Ad" CONNECTION (FDC) I \ I z 46 ►�+ FIRE HYDRANT REDUCER "'°c I \\ o I ® ° \\ N WATER VALVE , LU WATER TEE ° m \ \\ m \ II p p IV4 SANITARY ANGLE Gresham \\ I � I , I SO ® SANITARY STRUCTURES Smith 00 \\ II OS SANITARY MANHOLE N \I I\ \ ® SANITARY CLEANOUT lip 00 0 El \ \\ I STRUCTURE A4 A5 STRUCTURE LABEL / o I \ \ I RIM:195.11 o•` j \ \ I J°y\ ��\ IAOs h evi I I e ❑ i \ \, II a REG IONAL AIRPORT � I Asheville Regional 0� I II �? NOTE: z Airport 1. CONTRACTOR TO COORDINATE Terminal o° c, , I z N UNDERGROUND UTILITIES TO BE A MINIMUM OF "' 3 INCHES CLEAR BELOW THE BASE OF THE Modernization \ IZ z GRADE BEAMS WHEN PASSING UNDERNEATH.\ 61 Terminal Drive Suite 1 2. NO UTILITY LINES SHALL PENETRATE THE Foci i \ I zZ FOOTING AT THE CENTRAL ENERGY PLANT Fletcher, North Carolina 28732 EXCEPT FUEL LINES. 3. CONTRACTOR TO COORDINATE ALL ® J \ UNDERGROUND UTILITY ROUTINGS. UTILITIES 02/16/2022 SHALL BE KEPT A MINIMUM OF 12 INCHES \ I @ CLEAR FROM ALL FOUNDATIONS IN PLAN. GS Project#: 43483.02 0 v \\°o�` I T � � // 4 SEE SITE ELECTRICAL PLANS O POWER, COMMUNICATIONS, AND SITE LIGHTIN in 00c � _ m � -co I i Zd oj � ^ CD chch � Z - °Jr�m "tNN f5lMMm UUX X �� J9n /ice / 0 =, EA °UvOZZ �Q0 » � Lmom � aU Z o 053149CD / 11tip:/Q2/2zz • = N ^� I Z ^ NNN I NE��•v\�� CO m NNN / / //'/�77� t IDI I I I IIHVOCN\\�� � N ?�w QO > > > i C) Z Z Z& 0 O ® // EICL l9n 19n l�n 1 °l�n ®� ® NATHAN HUDGENS, PE M O O o — UGE E1 J - - O — — — _ — j i� NC 053149 � _ _ — - -__ - - - - - _ =---__—_—_ _ _ N - - - - - - - - - - - — ° 3 � � � 6Ge `tom N — — - . - - - - - - — — — — — — —-— — ----- ^ - - \ wrmicyy)) REVISION z C N N NO. DATE DESCRIPTION O a Z 1 02/16/22 ISSUE FOR CONSTRUCTION EXISTING SANITARY i � •0• \ p �O Z Z 2 05/02/22 AGENCY COMMENTS MANHOLE RIM ELEVATION TO .—.—._ BE MAINTAINED AT 2144.59 TIE TO EXISTING MANHOLE —' J� TIE TO EXISTING MANHOLE 3 08/19/22 AGENCY COMMENTS IE (IN): 2140.60 IE (IN): 2129.90 \\ O 4 11/02/22 ASI 007 \ U — — ' • \ . _ \\\ \ 2 PVC @ 1.00% D ' _ \.\ ` \ -0 UGE D D _ _ _ _ \ v U I °. v v °. ° v.'. V ? o rs ' I UGE v ° N d ° .D ? .v ❑ .D °. C O°. .DO o. DdOO O\ '.v ° D ° v °, D D ° D° v 5 L.F. -4" PVC @ 1.00% ` o D ..o - °o CY) o .1� rt1 V. ° ° GF °o\ PROJECT CO IE (OUT): 2141.00 °\o BOUNDARY CL SEE PLUMBING PLANS FOR OR <` ` \°\ CONTINUATION OF SANITARY LINE o I o D I o O \ ° a • \ Q I I ------------ _ °\ '�. o D v • I i `; \ \ O CD CD FIRE DEPARTMENT CONNECTION. -/ I 20' 0 20' 40' CD p SEE FIRE PROTECTION PLANS FOR DETAIL. ; o I o • I U ; O GRAPHIC SCALE co UTILITY PLAN 00 KEYPLAN I �I Al ' A2 ' A3 �� CL501A3 . P2 �0 — — — — —i - - - - - i- - - - - Q UTILITY PLAN B1 � B2 � B3 A3 SCALE: =20'1" O CONSTRUCTION DOCUMENTS I