HomeMy WebLinkAboutSW1221002_Plansheet CL501A2.P2 - Other_20230223 m� 3on
LEGEND
o N N I� 19/t
PROPERTY LINE
w z o BUILDING LINE
��. Gresham Smith
W WATER LINE (SIZE VARIES) GS-NC P.C.
° An Affiliate of Gresham Smith
I u I — _ _ _ _ _ — SANITARY SEWER
o — — — — — — — STORM SEWER
UGE GE '' °
I
I I _UG-E UNDERGROUND ELECTRIC
m I 201 South College St.
G NATURAL GAS Suite 1950
® C Charlotte, NC 28244
W W W i — — — — — — — UTILITY EASEMENT 704.944.7970
FIRE DEPARTMENT
CONNECTION (FDC)
o
I ►�+ FIRE HYDRANT
,�1
® I REDUCER
° I° ►N WATER VALVE ,
� ® I
I WATER TEE
I � � i p p '�4 IV4 SANITARY ANGLE Gresham
I SO ® SANITARY STRUCTURES
Smith
� m I
® I O SANITARY MANHOLE
® I
® SANITARY CLEANOUT
I
-----FOC-- F ° STRUCTURE A4 A5
————Foci I STRUCTURE LABEL /
N I RIM:195.11
Z m I
m 0 I
zNN ® ® s eville
U I o
Q � m � REGIONAL AIRPORT
UGE - - - - I Asheville Regional
o
E � °
Z m i NOTE: Airport
° Terminal
� i 1. CONTRACTOR TO COORDINATE
z N` ° UNDERGROUND UTILITIES TO BE A MINIMUM OF
`U� 3 INCHES CLEAR BELOW THE BASE OF THE Modernization
I GRADE BEAMS WHEN PASSING UNDERNEATH.
2. NO UTILITY LINES SHALL PENETRATE THE
cV N � ® � 61 Terminal Drive Suite 1
z FOOTING AT THE CENTRAL ENERGY PLANT Fletcher, North Carolina 28732
EXCEPT FUEL LINES.
3. CONTRACTOR TO COORDINATE ALL
Z 4 Q a a^ 02/16/2022
O 0 C) UNDERGROUND UTILITY ROUTINGS. UTILITIES
a, SHALL BE KEPT A MINIMUM OF 12 INCHES
UG o = I C N C�, GS Project#: 43483.02
rn� CLEAR FROM ALL FOUNDATIONS IN PLAN.
o GE L°—°—° o ^ m 4. SEE SITE ELECTRICAL PLANS FOR POWER,
N Z 6) o w COMMUNICATIONS, AND SITE LIGHTING.
� rrN , v� �t "t � m
Qd `- �
Q N a 0 CO d N N
., N
^�
= U N Z
z � o � � zzz p�N '��/ ',
o� 's•s i
Q m _ SEAL
3 as J o md� NN
.a r•
U U m U = I U N Z _ 10/2'4/2f
053149
60 CD
Lu
Z - mm W mU • N Z UF- zz ///// /Vf�IDjIII��Hvo�\\\\\
find d Z V- F- Z ^ � 0 NN
3 m � N (V 0 NZO COON o a_' O >
0 ..- ooCL z UNZ oF- ? j 1
O c#7 UG ,rt� �_—� �AN anr� UG UGE 145.95
H{i °
° ° ° ° x x X— aI —fix @x� x x ° x Zb x 1 1�n 1 NATHAN HUDGENS, PE
m mm m m®� ®O e fb e® � len @®��® �����m m ® ® mre ® mac
NC 053149
N
N — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
O - - - - - - - - - - - — _ _ — _ - - - - - — REVISION
o I ADJUST EXISTING SANITARY
O I MANHOLE TO BE FLUSH I NO. DATE DESCRIPTION
WITH PROPOSED GRADE 1 02/16/22 ISSUE FOR CONSTRUCTION
- SS-A6 •
j PROJECT a RIM:2145.81 ADJUST EXISTING SANITARY I ' I 2 03/28/22 ADDENDUM 03
O BOUNDARY INV IN:2135.48 8" DIP (N) MANHOLE TO BE FLUSH I _ _ — I SS-A5 3 05/02/22 AGENCY COMMENTS
INV IN:2139.47 4" PVC (W) WITH PROPOSED GRADE RIM:2145.74 4 10/24/22 ASI 006
a> - ///
� .—.—.—.—•— — _ INV IN:2138.79 4" PVC (W)
v — — -- -- -- -- -- S
369 L.F. - 8" DIP @ 0.509
All 21
26 L.F. -4" PVC @ 1.00% 21 L.F. -4" PVC @ 1.00%
° o °
Q) V.
—
U ° . V D V o ° D D'° °p . D D D pv
° D° .► ° Do'. D.. D ° .,,� C .. ° .V ° �� ° ° ° ° '.,° D'. �� D DV D
n° v 10 L.F. -4 PVC 1.00% ° v D P o °
OO ° C D °❑ C 'Dv ° O °. b LJ. ..° ° •° `❑ °p @F D ° ° D . p❑ v �10LF 4 PVC@1 � °
° b V
00
°°
D
M
D D
O
\ CONNECT EXISTING WATER LINE TO
\ \ ��eg BUILDING. SEE FIRE PROTECTION PLANS IE (OUT): 2139.00
J � 3a� FOR CONTINUATION OF WATER LINE. SEE PLUMBING PLANS FOR
00 08 EXTERIOR CLEANOUT IE (OUT): 2139.83 CONTINUATION OF SANITARY LINE
CL902.P2 (TYP.) SEE PLUMBING PLANS FOR LU � a a a
U CONTINUATION OF SANITARY LINE O ui 2 2 U
2d- UUx
V_ 4 QNCO (pN
O 2 Q_F_
i � O t -tN
N (V °J
O � � m 20' 0 20' 40'
V_ W N N r-
.. N
OUTILITY PLAN
Z c GRAPHIC SCALE
M
00 KEYPLAN
O
I
�I Al ' A2 ' A3
CL501A2 . P2
�0 — — — — —i - - - - - i- - - - -
Q
UTILITY PLAN B1 B2 B3
A2
SCALE: 1"=20'
O
CONSTRUCTION DOCUMENTS