Loading...
HomeMy WebLinkAboutSW6230104_Soils/Geotechnical Report_20230126 (2)untertek psi March 20, 2022 Mr. Gabriel Martinez Embree Development Group, Inc. 4747 Williams Drive Georgetown, Texas 78633 E-mail: gmartinez(o-)_embreegroup.com Intertek - PSI 5021-A W. WT Harris Blvd. Charlotte, North Carolina 28269 Re: Report of Geotechnical Engineering Services Proposed Retail Pet Supply Facility NWQ West Cumberland Street (US Hwy 421) and Marlowe Drive Dunn, North Carolina PSI Report No.: 05111058 Dear Mr. Martinez: Phone: (704) 598-2234 Fax: (704) 598-2236 Professional Service Industries (PSI), an Intertek Company, is pleased to transmit our Geotechnical Engineering Services Report for the proposed Retail Pet Supply Facility to be located in Dunn, North Carolina. This report includes the results of field and laboratory testing, and recommendations for foundation and pavement design, as well as general site development. PSI appreciates the opportunity to perform this Geotechnical Study and look forward to continued participation during the design and construction phases of this project. If you have any questions pertaining to this report, or if PSI may be of further service, please contact our office at 704-598- 2234. PSI also has great interest in providing materials testing and inspection services during the construction of this project. If you will advise us of the appropriate time to discuss these engineering services, we will be pleased to meet with you at your convenience. Very truly yours, PROFESSIONAL SERVICE INDUSTRIES, INC. Andrew O. Steege, P.G. Senior Geologist Digitally signed Karl E by Karl E Suter Suter Date: 2022.05.20 08:04:22-04'00' Karl E. Suter, P.E. Principal Consultant 1( CA1R0 ti9 SEAL - 027655 = www.intertek.com/building '^ Y 1 Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 LonMarch 20, 2022 TABLE OF CONTENTS 1 PROJECT INFORMATION.....................................................................................1 1.1 PROPOSAL AND PROJECT AUTHORIZATION ............................................ 1 1.2 PROJECT DESCRIPTION.............................................................................. 1 1.3 PURPOSE AND SCOPE OF WORK.............................................................. 1 2 EXPLORATION PROCEDURES............................................................................ 2 2.1 FIELD SERVICES........................................................................................... 2 2.2 LABORATORY TESTING............................................................................... 3 3 SITE AND SUBSURFACE CONDITIONS.............................................................. 3 3.1 SITE DESCRIPTION....................................................................................... 3 3.2 SITE GEOLOGY............................................................................................. 4 3.3 SUBSURFACE CONDITIONS........................................................................ 4 4 GEOTECHNICAL EVALUATION AND RECOMMENDATIONS ............................ 6 4.1 GEOTECHNICAL ASSESSMENT.................................................................. 6 4.2 SITE PREPARATION AND EARTHWORK..................................................... 7 4.3 SEISMIC CONSIDERATIONS........................................................................ 9 4.4 FOUNDATION RECOMMENDATIONS........................................................ 10 4.5 FLOOR SLAB RECOMMENDATIONS......................................................... 11 4.6 PAVEMENT RECOMMENDATIONS............................................................ 12 5 CONSTRUCTION CONSIDERATIONS................................................................15 5.1 GROUNDWATER......................................................................................... 15 5.2 EXCAVATIONS AND SAFETY..................................................................... 15 6 REPORT LIMITATIONS.......................................................................................16 APPENDIX Site Vicinity Map Boring Location Plan General Notes and Soil Classification Chart Boring Logs Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 PROJECT INFORMATION 1.1 PROPOSAL AND PROJECT AUTHORIZATION This report presents our findings and recommendations of a geotechnical exploration and assessment performed by Professional Service Industries (PSI) for the proposed Retail Pet Supply Facility to be located in Dunn, North Carolina. These services were performed in general accordance with a "Geotech Report Work Order" that references PSI Proposal No. 0511-366347 dated February 17, 2022. Authorization to proceed was given to PSI on March 16, 2022. 1.2 PROJECT DESCRIPTION Project information was provided through an emailed request for proposal (RFP) from Gabriel Martinez of Embree Development Group, Inc. (EDG) on February 15, 2022. The RFP included a drawing titled, "Conceptual Site Plan," prepared by EDG and dated October 14, 2021, that presents proposed construction and some existing site features. Based on the information provided, we understand that the proposed project will consist of the construction of a new pet supply facility on the approximately 1.67-acre site. The project will include the construction of a single -story retail building with a footprint of 10,900 square feet in the north - central portion of the property. Details regarding the proposed construction were not provided to PSI. We anticipate the building will be a pre-engineered metal building with masonry or stucco veneer and a concrete slab -on -grade (no basement). Structural loading information was not provided. We estimate typical column and wall loads of 75 kips and 3 kips per foot, respectively. Parking areas utilizing asphalt and concrete pavement will be constructed over much of the remaining site area. A traffic design load of 150,000 ESALs for a 20-year pavement life was provided in the "Geotech Report Work Order". Proposed stormwater management facilities were not indicated on the provided plan, therefore; we anticipate drainage will be diverted offsite and have excluded soil borings for stormwater management facilities from our proposed scope of services. Proposed grading and existing topographic information were not provided. Based on our site observations, the ground surface across most of the site is generally flat and level or has a gradual downward slope to the west. We estimate maximum cut and fill depths for site grading will be about 1 to 2 feet. The information presented in this section was used in the evaluation. Estimated loads and corresponding foundation sizes have a direct effect on the recommendations, including the type of foundation, the allowable soil bearing capacity, and the estimated settlement. In addition, estimated subgrade elevations and cut/fill quantities can have a direct effect on the provided recommendations. If any of the noted information is incorrect or has changed, please inform PSI so that we may amend the recommendations presented in this report, if appropriate. If PSI is not retained to perform this function, PSI cannot be responsible for the impact of the changes on the performance of the project. 1.3 PURPOSE AND SCOPE OF WORK The purpose of this study was to obtain information regarding the general subsurface conditions within the proposed construction area, to assess the engineering characteristics of the subsurface materials, Page 1 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 and to provide general design recommendations regarding the geotechnical aspects of the proposed construction. To accomplish this, PSI performed a brief site reconnaissance, drilled six soil test borings within the areas of proposed site improvements, conducted laboratory classification testing on recovered samples and prepared this report summarizing the findings, as well as our conclusions and recommendations. The scope of our geotechnical services did not include an environmental assessment for determining the presence or absence of wetlands, or hazardous or toxic materials in the soil, bedrock, groundwater, or air, on or below or around this site. Any statement in this report or on the boring logs regarding odors, colors, unusual or unexpected items, or conditions are strictly for the information of our client. PSI did not provide nor was it requested to provide any service to investigate or detect the presence of moisture, mold or other biological contaminants in or around any structure, or any service that was designed or intended to prevent or lower the risk of the occurrence of the amplification of the same. Client acknowledges that mold is ubiquitous to the environment with mold amplification occurring when building materials are impacted by moisture. Client further acknowledges that site conditions are outside of PSI's control, and that mold amplification will likely occur, or continue to occur, in the presence of moisture. As such, PSI cannot and shall not be held responsible for the occurrence or recurrence of mold amplification. 2 EXPLORATION PROCEDURES 2.1 FIELD SERVICES PSI advanced six soil test borings (Borings B-1 through B-6) within the proposed site. Borings B-1 through B-4 were drilled within the proposed building footprint area, and borings B-5 and B-6 were drilled within proposed pavement areas. The approximate boring locations are shown on the "Boring Location Plan" (Figure 2) included in the Appendix. Horizontal and vertical survey control was not performed for the test boring locations prior to our field exploration program. The borings were located by estimating distances and relationships to obvious landmarks, and the drawings provided by the client. Topographic information was not provided so the subsurface materials encountered are referenced by depth from the existing ground surface at the boring locations. Soil test borings were advanced at this site by HPC, a subcontractor hired by PSI, utilizing a CME-550 ATV -mounted drilling rig using mud rotary drilling techniques or hollow -stem, continuous -flight augers. All boring and sampling operations were conducted in general compliance with ASTM D 1586. At regular intervals, soil samples were obtained with a standard 2-inch O.D. split -barrel sampler. An automatic trip drop hammer was used for the standard penetration testing, which generally has a higher efficiency than a manual cathead-and-rope hammer. Typically, the automatic hammer yields lower standard penetration test resistances (N-values) than a manual cath ead-a nd -rope hammer. This reduction has been taken into account in our evaluation. However, the N-values reported on the logs, and the consistency descriptions on the boring logs are based on the field -recorded values and were not corrected for hammer efficiency. The recovered soil samples were classified visually in the field by the drill crew, then transported to our laboratory for additional visual classification and laboratory testing by a geologist. A "Boring Log" was Page 2 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 prepared for each boring and the "Logs" are included in the Appendix of the report. The logs were prepared using the observations made in the field, as well as the classifications in the laboratory and the laboratory test results. Strata descriptions, presented on the logs, were based on visual -manual evaluations by our geologist and include the classifications in general accordance with the Unified Soil Classification System (USCS). The "Soil Classification Chart", included in the Appendix, illustrates the USCS legend depicted on the logs. Existing topographic information was not provided, therefore; ground surface elevations are not presented on the boring logs or referenced in this report. Groundwater infiltration levels were measured in the boreholes at the time of boring and upon completion. The results of the readings are presented in Section 3.3.5 and included on the soil test boring logs. The borings were backfilled upon completion using the soil cuttings or bentonite chips for safety considerations. Therefore, delayed groundwater level readings are not available. 2.2 LABORATORY TESTING A geologist visually -manually classified the soil samples in the laboratory in general accordance with the Unified Soil Classification System (USCS) (ASTM D2487 and D2488). Percent finer than the No. 200 sieve (ASTM D1140), Atterberg limits tests (ASTM D4318), and natural water content determinations (ASTM D2216) were conducted on representative samples recovered from the test boring locations. The laboratory test results are presented in Section 3.3.6 and are shown on the individual boring logs. 3 SITE AND SUBSURFACE CONDITIONS 3.1 SITE DESCRIPTION The site encompasses a reported area of 1.67 acres and is located at the northwest quadrant of the intersection of West Cumberland Street (US Hwy 421) and Marlowe Drive in Dunn, North Carolina. The site is situated about 300 to 600 feet east of the south flowing Black River. The site location is depicted on the "Site Vicinity Map" (Figure 1) included in the Appendix. At the time of our site reconnaissance (April 2022), the site was covered with trees and/or heavy underbrush. Buried and overhead utility lines were observed along the south site boundary (adjacent to West Cumberland Street). The ground surface across most of the site is generally flat and level or has a gradual downward slope to the west. We estimate site relief to be on the order of 3 feet. PSI reviewed historical aerial photos available on Google Earth. Based on this, the site appears as wooded in 1994 and cleared and graded from 2000 until around 2013 when thick vegetation began covering the site. At the time of our field investigation, the ground surface across most of the site was generally firm and dry and our equipment (an ATV -mounted drill rig) experienced no apparent difficulty moving across the site. However, due to the wooded nature of the site, clearing with heavy equipment was needed for access of our drilling equipment. Page 3 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 3.2 SITE GEOLOGY The project site is located within Harnett County, North Carolina, and lies within the Coastal Plain Physiographic Province of the eastern United States. This province is characterized by gently sloping plains containing numerous broad, slowly moving rivers with broad flood plains. Low-lying marsh and swamp regions are also prevalent. The Coastal Plain is comprised of sediments (mainly sands and clays) that have been transported eastward from highlands to the west by erosional forces. Some of these sediments have been consolidated to form sedimentary rock beds such as sandstone and mudstone; however, often the sediments are poorly consolidated or unconsolidated. This process began approximately 200 million years ago and, based on seismic refraction and well data, the depth of these sediments to the underlying basement rock ranges from less than 10 feet at the fall line (the western boundary of the Coastal Plain and the eastern boundary of the Piedmont) to approximately 10,000 feet at the Outer Banks of North Carolina. Deposition commonly occurred beneath the sea and numerous lenses and beds of hard limestone also occur within the Coastal Plain strata. Review of the Geologic Map of North Carolina (compiled by the North Carolina Geological Survey, 1985) indicates that Coastal Plain sediments of the Cretaceous age Middendorf formation outcrop at the subject site. These sediments are described primarily as sands, sandstone and mudstone. Previously placed fill soils were encountered at the borings, and fill materials are often encountered on previously developed sites such as this. The suitability of existing fill can vary significantly across the site. It is not uncommon to encounter buried debris and unsuitable materials on previously developed sites. 3.3 SUBSURFACE CONDITIONS General subsurface conditions encountered during the subsurface exploration are described below. For more detailed soil descriptions and stratifications at the boring locations, the Boring Logs should be reviewed. The Boring Logs represent our interpretation of the subsurface conditions based on a review of the field logs and an engineering examination of the samples. The horizontal stratification lines designating the interface between various strata represent approximate boundaries. Transition between different strata in the field may be gradual in both the horizontal and vertical directions. Groundwater, or lack thereof, encountered in the borings and noted on the "Boring Logs" represents conditions only at the time of the exploration. 3.3.1 SURFACE Initially the borings encountered a layer of topsoil approximately 3 to 6 inches thick. However, deeper pockets of topsoil may be present in other areas of the site. The term topsoil, as used in this report, is a general designation given to the surface horizon of soil which appears to have an elevated organic content. No laboratory testing was performed on the topsoil to determine its suitability for supporting plant life, or ability to satisfy a particular specification. Page 4 of 16 Lon 3.3.2 FILL Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 Apparent previously placed fill material was encountered beneath the topsoil layer at the borings. The apparent fill soils extended to depths ranging from about 3 to 5 '/2 feet beneath the existing ground surface and generally consisted of loose to medium dense Silty SAND (SM) with rock fragments. The Standard Penetration Test resistances (N-values) recorded in the apparent fill material ranged from 10 to 28 blows per foot (bpf) suggesting moderate to good compaction. 3.3.3 ALLUVIUM Apparent alluvial soils were encountered beneath the fill material at the borings, extending to depths ranging from about 17 to 22 feet beneath the existing ground surface. The alluvium encountered at the borings generally consisted of loose Silty Clayey SAND (SC-SM), very loose to medium dense Silty SAND (SM), loose to medium dense Clayey SAND (SC), very loose to medium dense GRAVEL with Sand and Silt (GM), medium dense Clayey GRAVEL (GC), and medium dense Well Graded GRAVEL (GW). Lesser amounts of soft to firm Lean CLAY (CL) were also encountered. The N-values recorded in the apparent alluvial soils at the borings ranged from 2 to 20 bpf but were generally in the 4 to 15 bpf range. Alluvial soils are deposited by water and often are poorly consolidated. Borings B-5 and B-6 were terminated in the apparent alluvium at a depth of about 10 feet beneath the existing ground surface. 3.3.4 COASTAL PLAIN DEPOSITS Coastal plain deposit soils were encountered beneath the apparent alluvial soil layer at borings B-1 through B-4. These soils generally consisted of medium dense to dense Clayey SAND (SC) and medium dense Well Graded SAND (SW). The N-values recorded in these coastal plain deposit soils ranged from 11 to 46 bpf. Borings B-1 through B-4 were terminated in the coastal plain deposit soils at depths ranging from 20 to 50 feet below the existing ground surface. 3.3.5 GROUNDWATER INFORMATION The borings were checked for groundwater at the time of drilling. Mud rotary drilling techniques were employed for boring B-1. This drill method introduces water and drilling mud into the boring during drilling. Therefore, the groundwater level recorded upon completion was not available for boring B-1. Hollow stem augers were used to drill B-2 through B-6, enabling groundwater levels to be recorded after drilling at these borings. The boreholes were backfilled with bentonite chips or the auger cuttings upon completion. Therefore, delayed groundwater checks were not made. Groundwater infiltration was noted in four of the borings at the approximate depths presented in the following table. Groundwater Depths Approximate Depth to Approximate Depth to Groundwater Boring Groundwater at Time of Drilling at the Completion of Drilling (feet) (feet) B-1 7 N/A B-2 12 12'/2 B-3 11 12 B-4 12 13'/2 Page 5 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 Subsurface water levels within this region tend to fluctuate with seasonal and climatic changes, as well as with some types of construction operations. Generally, the highest groundwater levels occur in late winter and early spring, and the lowest levels in late summer and early fall. Therefore, water may be encountered during construction at depths not indicated during this study. Additionally, perched groundwater conditions can develop over low permeability soil or weathered rock following periods of heavy or prolonged precipitation. Groundwater may be encountered during construction at depths not indicated during this exploration. 3.3.6 LABORATORY TEST RESULTS The results of the laboratory testing program are summarized in the following table. Sample Location Sample Depth (ft) Moisture Content % Percent Fines % ATTERBERG LIMITS USCS Soil Classification LL PL PI B-1 1 —2'/2 15.3 22.6 -- -- -- SC* B-1 3'/2 - 5 14.9 39.1 19 13 6 SC-SM B-1 13'/2 - 15 16.4 14.0 -- -- -- GC* B-1 18'/2 - 20 21.0 4.2 -- -- -- GW* B-1 23'/2 - 25 19.5 21.6 30 18 12 SC B-1 38'/2 - 40 19.4 12.9 -- -- -- SC* B-1 48'/2 - 50 24.9 4.0 -- -- -- SW* * Based on visual classification 4 GEOTECHNICAL EVALUATION AND RECOMMENDATIONS 4.1 GEOTECHNICAL ASSESSMENT The following geotechnical design recommendations have been developed on the basis of the previously described project characteristics and subsurface conditions encountered. If there are any changes in these project criteria, including building location on the site or the construction of earth retaining structures are required, a review should be made by PSI to determine if modifications to the recommendations are warranted. Once final design plans and specifications are available, a general review by PSI is recommended as a means to check that the evaluations made in preparation of this report are correct and that earthwork and foundation recommendations are properly interpreted and implemented. Based on the results of the fieldwork, laboratory evaluation and engineering analyses, the presence of previously placed fill material overlying alluvium is a potential constraint to site development, as discussed further below. Page 6 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 Previously placed fill soils were encountered at the boring locations extending to depths ranging from about 3 feet to 5'/2 feet beneath the existing ground surface. The apparent fill consisted of loose to medium dense Silty SAND (SM) with rock fragments. Organic material and other foreign debris were not noted in the sampled fill material. Standard Penetration Test resistances (N-values) ranging from 10 to 28 blows per foot (bpf) were recorded in the apparent fill. These N-values suggest a moderate to good level of compaction. PSI was not provided with field test data related to the fill placement. If such information exists, we recommend that the owner obtain that data and provide it to PSI for review. A subsurface exploration, performed after fill is placed, is limited in evaluating whether the fill materials were compacted in a controlled manner, regardless of the number of borings or amount of laboratory testing performed. If fill placement and compaction records are not available, the owner must be willing to accept some risk when building on undocumented fill. Based upon the results of our limited exploration, the limited site grading anticipated and the estimated light structural loads we assess the risk as relatively low. Proofrolling the site following site stripping can often detect significant concentrations of soft, wet or unsuitable materials which can be selectively undercut and replaced. As discussed earlier in this report, primarily sandy or gravelly alluvial soil was encountered beneath the fill at the borings. The N-values recorded in the apparent alluvial soils at the borings ranged from 2 to 20 bpf but were generally in the 4 to 15 bpf range. We note that a layer of low N-value material was consistently encountered in the borings at a depth of about 8 feet. Due to the low N-value layer we recommend a relatively low maximum allowable bearing pressure of 2,000 psf and that foundations be kept as shallow as possible to bear at least 5 feet above this lower N-value layer (while still having adequate embedment). Based on the borings, it appears much of the site soil material will be suitable for reuse as structural fill. However, these soils should be examined by the geotechnical engineer to ensure it conforms to the standards presented in Section 4.2. Depending on water conditions, some moisture conditioning (drying) of the soils may be needed prior to reuse. It will be critical that these operations be conducted during dry weather conditions only. 4.2 SITE PREPARATION AND EARTHWORK Site clearing, stripping and grubbing operations should only be performed in dry weather conditions. Initially, wet soils, topsoil, organics, debris, utilities, and other unsuitable materials, should be stripped from an area extending at least 10 feet beyond the outline of the proposed construction. Removal of trees should also include removal of their stumps and root balls, which can extend to several feet below grade. Any existing below -grade construction encountered during site grading or construction should be examined by the Geotechnical Engineer to determine if these materials will require removal. Depressions or low areas resulting from stripping and grubbing or removal of other subsurface appurtenances should be backfilled with compacted structural fill in accordance with the recommendations presented in this report. After stripping, removal of unsuitable surface soils, and rough excavation grading, we recommend that areas to provide support for the floor slabs, pavements, and/or structural fill be evaluated for the Page 7 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 presence of soft or loose, surficial soils by proofrolling and inspection by the Geotechnical Engineer. The proofroll should be performed using a loaded tandem axle dump truck, or similar rubber -tired equipment, weighing between 15 and 25 tons. The vehicle should make at least four passes over each location, with the last two passes perpendicular to the first two. Areas that wave, rut, or deflect significantly and continue to do so after several passes of the proofroller should be undercut to firmer soils as recommended by the Geotechnical Engineer. Undercut areas should be backfilled in thin lifts with approved, compacted fill materials. Proofroll operations should be monitored carefully by PSI's Project Geotechnical Engineer. Drying soils for re -use as structural fill is often considered a routine aspect of typical grading operations and is not considered a pay item. If unit prices for earthwork operations are established, they should be examined closely before the contract is executed. If undercutting is a pay item, then undercut volumes should be determined by field measurement. Methods such as counting trucks should not be used for determination of undercut volume, as they are less accurate. Recommended criteria for soil fill characteristics (both on -site and imported materials) and compaction procedures are listed below. The project design documents should include the following recommendations to address proper placement and compaction of project fill materials. Earthwork operations should not begin until representative samples are collected and tested. The maximum dry density and optimum moisture content should be determined. EARTH FILL MATERIALS Imported and on -site fill material satisfactory for structural fill should include clean soil material with USCS classifications of (GW, GM, SW, SP, SM, and some SC, CL or ML). The fill material should have a Standard Proctor (ASTM D698) Maximum Dry Density of at least 100 pcf, a maximum Liquid Limit of 45 and a Plasticity Index of 25 or less. Fat CLAY (CH) and Elastic SILT (MH) soils should not be used as structural fill. Organic content or other foreign matter (debris) should be no greater than 3 percent by weight, and no large roots (greater than '/4 inch in diameter) should be allowed. Organic materials should not be intentionally mixed into structural fill. Material utilized as fill should not contain rocks greater that 3 inches in diameter or greater than 30 percent retained on the 3/4-inch sieve. COMPACTION RECOMMENDATIONS Maximum loose lift thickness — 8 inches, mass fill. Loose lifts of 4 to 6 inches in trenches and other confined spaces where hand operated equipment is used. Compaction requirements — 95 percent of the maximum dry density and 98 percent within the upper 12 inches as determined by the standard Proctor (ASTM D698) compaction test. Soil moisture content at time of compaction — within ±3 percent of the optimum moisture content. Page 8 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 TEST CRITERIA TO EVALUATE FILL AND COMPACTION One standard Proctor compaction test and one Atterberg limits test for each soil type used as project fill. Gradation tests may be necessary and should be performed at the Geotechnical Engineer's discretion. One density test every 2,500 square feet for each lift or two tests per lift, whichever is greater (for preliminary planning only; the test frequency should be determined by our engineering staff). Trench fill areas — one density test every 75 linear feet at vertical intervals of 2 feet or less. It will be important to maintain positive site drainage throughout construction. Storm water runoff should be diverted around the building and pavement areas. The site should be graded at all times such that water is not allowed to pond. The surface should be sealed with a smooth drum roller to enhance drainage if precipitation is expected. Subgrades damaged by construction equipment should be repaired immediately to avoid further degradation in adjacent areas and to help prevent water ponding. Should there be a significant time lag or period of inclement weather between site grading and the fine grading of the slab prior to the placement of stone or concrete, the Geotechnical Engineer of Record or qualified representative should assess the condition of the prepared subgrade. The subgrade may require scarification and re -compaction or other remedial measures to provide a firm and unyielding subgrade prior to final slab construction. 4.3 SEISMIC CONSIDERATIONS The project site is located within a municipality that employs the 2015 International Building Code' (IBC). As part of this Code, the design of structures must consider dynamic forces resulting from seismic events. These forces are dependent upon the magnitude of the earthquake event, as well as the properties of the soils that underlie the site. As part of the procedure to evaluate seismic forces, the Code requires the evaluation of the Seismic Site Class, which categorizes the site based upon the characteristics of the subsurface profile within the upper 100 feet of the ground surface. To define the Site Class for this project, we first interpreted the results of soil test borings drilled within the project site and estimated appropriate soil properties below the base of the borings to a depth of 100 feet, as permitted by the Code. The estimated soil properties were based upon our experience with subsurface conditions in the general site area. Based upon the SPT N-values recorded during the field exploration, the subsurface conditions within the site are consistent with the characteristics of a Site Class "D" as defined in Table 1613.5.2 of the Code. The associated IBC (2015) probabilistic ground acceleration values and site coefficients for the general site area were obtained from the USGS U.S. Seismic Design Maps Web Application (http://geohazards.usgs.gov/designmaps/us/application.php) and are presented in the table below: Page 9 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 Ground Motion Values for Site Class "D"* Mapped MCE Adjusted MCE Design Period Spectral Site Spectral Spectral (sec) Response Coefficients Response Response Acceleration** Acceleration Acceleration 0.2 Ss 0.182 Fa 1.6 SMs 0.291 SD, 0.194 1.0 S, 0.085 F, 2.4 SM, 0.205 SD, 0.137 *2% Probability of Exceedance in 50 years for Latitude 35.32274 and Longitude-78.64007 **At B-C interface (i.e. top of bedrock). MCE = Maximum Considered Earthquake The Site Coefficients, Fa and F, presented in the above tables were obtained also from the noted USGS webpage, as a function of the site classification and mapped spectral response acceleration at the short (Ss) and 1-second (S,) periods but can also be interpolated from IBC Tables 1613.5.3(1) and 1613.5.3(2). 4.4 FOUNDATION RECOMMENDATIONS Based on the subsurface exploration performed at the site, the following recommendations are provided to support the proposed structure at the site. Based on the results of the geotechnical exploration and anticipated structural loads, the proposed structure can likely be supported on conventional shallow spread and wall footings. We recommend that footings be designed for a maximum net allowable soil bearing capacity of 2,000 psf. This recommendation assumes that the building foundations will bear in well -compacted existing fill or alluvium consisting of Silty SAND (SM) or Clayey SAND (SC), or new structural fill placed and compacted in accordance with the recommendations of this report. We recommend continuous wall and column footings with minimum widths of at least 18 inches and 24 inches, respectively regardless of the actual resulting bearing pressure. All foundation excavations should be evaluated for the presence of organic -laden and/or poorly compacted fill soils. As such, we recommend that Dynamic Cone Penetrometer (DCP) testing be performed within footing excavations and should extend to a minimum depth of 3 feet below the bottom of the foundation grade. If unsuitable bearing material such as poorly compacted or organic laden fill soils are found, they should be removed and replaced with a low -plastic structural fill to a depth of 2 feet below the footing bottom. If compacted structural fill is used as backfill, the undercut excavations to remove unsuitable materials should be centered beneath the footing and widened'/2 foot in each direction for each foot of undercut depth, measured from the outside edge of the new foundation. If lean concrete is used as backfill, the foundation excavation need not be widened. Open graded stone, such as No. 57 stone, should not be used as backfill beneath foundations because of the tendency of water to accumulate in open -graded aggregate. Page 10 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 All foundations should bear at a minimum depth of 18 inches below the lowest adjacent final ground surface for frost penetration, and protective embedment. However, as discussed in Section 4.1, due to a layer of low N-value material consistently encountered in the borings at a depth of about 8 feet, we recommend that foundations be kept as shallow as possible to bear at least 5 feet above this lower N-value layer. PSI recommends that the foundations be designed in accordance with the 2015 International Building Code. We estimate that footings with width no larger than 5 feet, designed and constructed in accordance with the recommendations herein will experience post -construction total settlements generally less than 1-inch with differential settlement along a 25-foot long portion of a continuous footing, or similarly spaced column footings generally less than '/2-inch. Total and differential settlements of these magnitudes are usually considered tolerable for the anticipated construction. However, the tolerance of the proposed structure to the predicted total and differential settlements should be confirmed by the structural engineer. Foundation concrete should be placed as soon as possible after excavation and after any needed over excavation and re -compaction. If foundation excavations must be left open overnight, or exposed to inclement weather, the base of the excavation should be protected with a "mud mat" consisting of 2 to 3 inches thick of lean concrete. Footing excavations should be protected from surface water run-off and freezing. If water is allowed to accumulate within a footing excavation and soften the bearing soils, or if the bearing soils are allowed to freeze, the deficient soils should be removed from the excavation prior to concrete placement. 4.5 FLOOR SLAB RECOMMENDATIONS Floor slabs may be supported on subgrades prepared in accordance with the SITE PREPARATION AND EARTHWORK section (paragraph 4.2) of this report. Where concrete slabs are designed as beams on an elastic foundation, the soils that will comprise the subgrade soils should be assumed to have a modulus of subgrade reaction (k) of 100 pounds per cubic inch (pci). This value is estimated based on the expected results of a plate load test using a nominal 1-foot by 1-foot plate. However, depending on how the slab load is applied, the value will have to be geometrically modified for larger areas. In order to provide uniform support beneath any proposed floor slab -on -grade, we recommend that floor slabs be underlain by a minimum of 4 inches of compacted aggregate base course material. The estimated modulus of subgrade reaction after the addition of 4 inches of aggregate subbase material is 150 pci. The aggregate base course material should be compacted to at least 98 percent of its standard Proctor maximum dry density. Open -graded crushed stone, such as No. 57 stone, may also be used; however, it is our experience that open graded crushed stone can collect water during periods of rain and cause saturation and softening of the subgrade soils prior to placement of the floor slab concrete. Therefore, construction sequencing/timing, and the season in which the stone is placed, should be taken into consideration. Page 11 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 The crushed rock or aggregate base is intended to provide a capillary break to limit migration of moisture through the slab. If additional protection against moisture vapor is desired, a vapor retarding membrane may also be incorporated into the design. Shallow groundwater encountered at the site indicates that there will be available moisture for transmission through the slab. Based on the subsurface materials and the intended use of the structure, we recommend the use of a vapor retarding membrane. Vapor retarders, if used, should be installed in accordance with ACI 302.1, Chapter 3. The precautions listed below should be closely followed for construction of slabs -on -grade. These details will not prevent the amount of slab movement but are intended to reduce potential damage should some settlement of the supporting subgrade take place. Cracking of slabs -on -grade is normal and should be expected. Cracking can occur not only as a result of heaving or compression of the supporting soil, but also as a result of concrete curing stresses. The occurrence of concrete shrinkage cracks, and problems associated with concrete curing may be reduced and/or controlled by limiting the water to cement ratio of the concrete, proper concrete placement, finishing, and curing, and by the placement of crack control joints at frequent intervals, particularly, where re-entrant slab corners occur. The American Concrete Institute (ACI) recommends a maximum panel size (in feet) equal to approximately three times the thickness of the slab (in inches) in both directions. For example, joints are recommended at a maximum spacing of 12 feet assuming a four -inch thick slab. We also recommend that control joints be scored three feet in from and parallel to all foundation walls. Using fiber reinforcement in the concrete can also help control shrinkage cracking. • Some increase in moisture content is inevitable as a result of development and associated landscaping; however, extreme moisture content increases can be largely controlled by proper and responsible site drainage, building maintenance and irrigation practices. All backfill in areas supporting slabs should be moisture conditioned and compacted as described earlier in this report. Backfill in all interior and exterior utility line trenches should be carefully compacted. • Exterior slabs should be isolated from the building. These slabs should be reinforced to function as independent units. Movement of these slabs should not be transmitted to the building foundation or superstructure. 4.6 PAVEMENT RECOMMENDATIONS 4.6.1 PAVEMENT SUBGRADE PREPARATION Following the stripping of deleterious materials, we recommend the proposed pavement subgrade be prepared and compacted in accordance with the recommendations provided in Section 4.2 "SITE PREPARATION AND EARTHWORK" of this report. We recommend proofrolling and re -compacting the upper 1-foot of subgrade immediately prior to placement of the aggregate base course (ABC). The exposed pavement subgrade should also be evaluated by a representative of PSI immediately prior to placing ABC. If low consistency soils are Page 12 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 encountered which cannot be adequately compacted in place, such soils should be removed and replaced with well -compacted soil fill or crushed stone materials. Based upon the assumed grading, we anticipate sandy Coastal Plain deposit soils, or newly -placed structural fill soils will be present at the proposed subgrade elevation. A California Bearing Ratio (CBR) value of about 6 can be reasonably assumed for the structural fill or native sandy soils at compaction levels of about 98 percent of the standard Proctor maximum dry density within about 3 percent of optimum moisture. Site grading is generally accomplished early in the construction phase. Subsequently as construction proceeds, the subgrade may be disturbed due to utility excavations, construction traffic, desiccation, and rainfall. As a result, the pavement subgrade may not be suitable for pavement construction and corrective action will be required. The subgrade should be carefully evaluated at the time of pavement construction and subgrade areas should be reworked, moisture conditioned, and property compacted to the recommendations in this report immediately prior to paving. Prevention of infiltration of water into the subgrade is essential for the successful long-term performance of any pavement. Both the subgrade and the pavement surface should be sloped to promote surface drainage away from the pavement structure. 4.6.2 FLEXIBLE PAVEMENT RECOMMENDATIONS EDG requested recommendations for flexible and rigid pavements and provided the following traffic loading information in their "Geotech Report Work Oder", dated September 2, 2021: 15,000 ESAL (light duty areas) 150,000 ESAL (heavy duty areas) Design Life: 20 years EDG requested PSI to base the recommended pavement sections on an estimated California Bearing Ratio (CBR) value developed by PSI. We anticipate that the traffic loads will be produced primarily by automobile traffic with weekly delivery and trash removal trucks. A conservative CBR value of 5 was estimated for the in -situ, low plasticity sands and silty sands, and newly placed structural fill. Structural fill placed in pavement areas should be compacted to 98 percent of the standard Proctor maximum dry density and within 3 percent of the optimum moisture content. Based on our experience with similar facilities and subgrade conditions, which are typical for this region, we recommend the following minimum pavement sections. If more detailed traffic loading information becomes available, the pavement sections designs should be reviewed and revised, if necessary. The pavement recommendations were based on "NCDOT Pavement Design Procedure", January 2019 and our experience with similar parking lots and delivery truck drive areas. The following assumptions were made in developing the flexible pavement recommendations: Reliability: 85% Standard Error: 0.45 Initial Serviceability: 4.2 Terminal Serviceability: 2.5 Page 13 of 16 Lon Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 RECOMMENDED MINIMUM MATERIAL THICKNESS FLEXIBLE inches TOTAL Aggregate Base Asphalt Course Asphalt Course PAVEMENT PAVEMENT SECTION SECTION Course INTERMEDIATE SURFACE (inches) (ABC) (I19.00) (S9.513) Light Duty Areas 6 1 1 3 (in two lifts) 9 Heavy Duty Areas 8 1 2 '/2 1 2 '/2 13 Notes: 1) Light Duty Areas calculated based on traffic loading of 15, 000 ESALS or less. Parking stalls only with no through traffic. Prime coat required between ABC and asphalt. 2) Heavy Duty Areas calculated based on traffic loading of 150, 000 ESALS or less. The pavement sections presented represent minimum section thicknesses for the traffic loadings provided. Since parking lot pavements are subject to additional abuses other than vehicle loading and tire contact, parking lot pavements require periodic maintenance to achieve the actual design life. 4.6.3 RIGID PAVEMENT RECOMMENDATIONS The use of concrete for paving has become more prevalent in recent years due to the long-term maintenance cost benefits of concrete compared to asphaltic pavements. Proper finishing of concrete pavements requires the use of appropriate construction joints to reduce the potential for cracking. Construction joints should be designed in accordance with current Portland Cement Association guidelines. Joints should be sealed to reduce the potential for water infiltration into pavement joints and subsequent infiltration into the supporting soils. The concrete should have a minimum compressive strength of 4,000 psi at 28 days. The concrete should also be designed with 5 ± 1 percent entrained air to improve workability and durability. All pavement materials and construction procedures should conform to NCDOT or appropriate city, county requirements. Large front -loading trash dump trucks frequently impose concentrated front -wheel loads on pavements during loading. This type of loading typically results in rutting of the pavement and ultimately, pavement failures. Therefore, we recommend that the pavement in trash pickup areas consist of a minimum 6-inch graded aggregate base overlain by a minimum 7-inch thick, rigid pavement. RIGID (CONCRETE) PAVEMENT LIGHT -DUTY' HEAVY-DUTY2 TRASH PICK-UP PAD Portland Cement Concrete (4,000 psi) 5 inches 6 inches 7 inches Aggregate Base Course (ABC) 4 inches 6 inches 6 inches Notes: 1) Light Duty Areas calculated based on traffic loading of 15, 000 ESALS or less. Parking stalls only with no through traffic. 2) Heavy Duty Areas calculated based on traffic loading of 150, 000 ESALS or less. Prime coat required between ABC and asphalt for all concrete pavement sections. Page 14 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 5 CONSTRUCTION CONSIDERATIONS 5.1 GROUNDWATER Groundwater level depths at the soil test borings immediately after drilling are in the range of about 7 to 13 feet below the existing grade at the site. Based on the borings, it appears that groundwater may not significantly impact at -grade construction but may be encountered in utility excavations. If encountered, we recommend that the groundwater table be lowered and maintained at a depth of at least 2 feet below foundation bearing elevations or below undercut excavation bottoms during construction. Adequate control of groundwater could likely be accomplished by means of pumping from open trenches, sump pits and gravel -lined, cased sumps for a lowering of 1 to 2 feet. However, groundwater lowering for utility installation may require the use of wellpoints. The contractor should be responsible for selecting the most optimal dewatering method. Furthermore, we recommend that the Contractor determine the actual groundwater levels at the time of construction to determine the groundwater impact on the construction procedures. Some dewatering is anticipated to be necessary for deep utility excavations. Groundwater levels within this region tend to fluctuate with seasonal and climatic changes, and confined pockets of perched water often occur above the groundwater table. Generally, the highest groundwater levels occur in late winter and early spring; and the lowest levels in late summer and early fall. Therefore, water may be encountered during construction at depths not indicated during this study. The contractor should be prepared to promptly remove surface water from the general construction area by similar methods. If groundwater is encountered during trenching or foundation installation, PSI should be notified so that we might determine whether there is a need for underslab drainage, perimeter drains, or other recommendations for dewatering. 5.2 EXCAVATIONS AND SAFETY Based on the data available from the borings, anticipated excavations during site grading will encounter medium dense soils that can generally be removed by conventional earthmoving equipment such as pans, scrapers, and backhoes. Some localized pre -loosening of higher consistency soils may be necessary. In Federal Register, Volume 54, No. 209 (October 1989), the United States Department of Labor, Occupational Safety and Health Administration (OSHA) amended its "Construction Standards for Excavations, 29 CFR, Part 1926, Subpart P". This document was issued to better allow for the safety of workers entering trenches or excavations. It is mandated by this federal regulation that excavations, whether they be utility trenches, basement excavations or footing excavations, be constructed in accordance with the new OSHA guidelines. It is our understanding that these regulations are being strictly enforced and if they are not closely followed, the owner and the Contractor could be liable for substantial penalties. The Contractor is solely responsible for designing and constructing stable, temporary excavations and should shore, slope, or bench the sides of the excavations as required to maintain stability of both the excavation sides and bottom. The Contractor's "responsible person", as defined in 29 CFR Part 1926, should evaluate the soil exposed in the excavations as part of the Contractor's safety procedures. In Page 15 of 16 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 no case should slope height, slope inclination, or excavation depth, including utility trench excavation depth, exceed those specified in all local, state, and federal safety regulations. We are providing this information solely as a service to our client. PSI does not assume responsibility for construction site safety or the Contractor's or other parties' compliance with local, state, and federal safety or other regulations. Groundwater control is critical to excavation safety and is described above. 6 REPORT LIMITATIONS The recommendations submitted are based on the available subsurface information obtained by PSI and design details furnished by Embree Development Group, Inc. for the proposed project. If there are any revisions to the plans for this project or if deviations from the subsurface conditions noted in this report are encountered during construction, PSI should be notified immediately to determine if changes in the foundation recommendations are required. If PSI is not retained to perform these functions, we will not be responsible for the impact of those conditions on the geotechnical recommendations for the project. PSI warrants that the findings, recommendations, specifications, or professional advice contained herein have been made in accordance with generally accepted professional geotechnical engineering practices in the local area at the date of this report. No other warranties are implied or expressed. After the plans and specifications are more complete, PSI should be retained and provided the opportunity to review the final design plans and specifications to check that our engineering recommendations have been properly incorporated into the design documents. At that time, it may be necessary to submit supplementary recommendations. This report has been prepared for the exclusive use of Embree Development Group, Inc. and their consultants for the specific application to the Proposed Retail Pet Supply Facility in Dunn, North Carolina. Page 16 of 16 Lon APPENDICES Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 SITE VICINITY MAP Project Name: Proposed Retail Pet Supply Facility NWQ W Cumberland Street and Marlowe Drive Dunn. North Carolina Project No.: Date: 05111058 May 2022 2018 Base Aerial Obtained From Google Earth Figure 1 Site Vicinity Map psi %r* W%%"0 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 BORING LOCATION PLAN m rRA8 � �sf=o�_ne� -- _ a -= SPEC O r `LIFT 7 _� � � � •,`� � pNGD +9�06 _S100, B-2� N55 pqR PVcU��R�Nos r Project Name: Proposed Retail Pet Supply Facility NWQ W Cumberland Street and Marlowe Drive Dunn, North Carolina Project No.: Date: 05111058 May 2022 Base Drawing "Conceptual Site Plan" Prepared by EMBREE Development, dated 10-14-2021 Figure 2 Boring Location Plan 4 NORTH Legend O Approximate Boring Location Approximate Scale As Shown untertC' P!*1 Proposed Retail Pet Supply Facility, Dunn, NC LonPSI Report No. 05111058 March 20, 2022 GENERAL NOTES AND SOIL CLASSIFICATION CHART GENERAL NOTES SAMPLE IDENTIFICATION The Unified Soil Classification System (USCS), AASHTO 1988 and ASTM designations D2487 and D-2488 are used to identify the encountered materials unless otherwise noted. Coarse -grained soils are defined as having more than 50% of their dry weight retained on a #200 sieve (0.075mm); they are described as: boulders, cobbles, gravel or sand. Fine-grained soils have less than 50% of their dry weight retained on a #200 sieve; they are defined as silts or clay depending on their Atterberg Limit attributes. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. DRILLING AND SAMPLING SYMBOLS SFA: Solid Flight Auger - typically 4" diameter SS: Split -Spoon - 1 3/8" I.D., 2" O.D., except flights, except where noted. where noted. HSA: Hollow Stem Auger - typically 3'/4" or 4'/4 I.D. ST: Shelby Tube - 3" O.D., except where noted. openings, except where noted. M.R.: Mud Rotary - Uses a rotary head with 0 RC: Rock Core Bentonite or Polymer Slurry ® TC: Texas Cone R.C.: Diamond Bit Core Sampler H.A.: Hand Auger BS: Bulk Sample P.A.: Power Auger - Handheld motorized auger 0 PM: Pressuremeter CPT-U: Cone Penetrometer Testing with Pore -Pressure Readings SOIL PROPERTY SYMBOLS N: Standard "N" penetration: Blows per foot of a 140 pound hammer falling 30 inches on a 2-inch O.D. Split -Spoon. N60: A "N" penetration value corrected to an equivalent 60% hammer energy transfer efficiency (ETR) Qu: Unconfined compressive strength, TSF QP: Pocket penetrometer value, unconfined compressive strength, TSF w%: Moisture/water content, % LL: Liquid Limit, % PL: Plastic Limit, % PI: Plasticity Index = (LL-PL),% DD: Dry unit weight, pcf 1 E,�r Apparent groundwater level at time noted RELATIVE DENSITY OF COARSE -GRAINED SOILS ANGULARITY OF COARSE -GRAINED PARTICLES Relative Density N - Blows/foot Description Criteria Very Loose 0-4 Angular: Particles have sharp edges and relatively plane Loose 4 - 10 sides with unpolished surfaces Medium Dense 10 - 30 Subangular: Particles are similar to angular description, but have Dense 30 - 50 rounded edges Very Dense 50 - 80 Subrounded: Particles have nearly plane sides, but have Extremely Dense 80+ well-rounded corners and edges Rounded: Particles have smoothly curved sides and no edges GRAIN -SIZE TERMINOLOGY PARTICLE SHAPE Component Size Range Description Criteria Boulders: Over 300 mm (>12 in.) Flat: Particles with width/thickness ratio > 3 Cobbles: 75 mm to 300 mm (3 in. to 12 in.) Elongated: Particles with length/width ratio > 3 Coarse -Grained Gravel: 19 mm to 75 mm (% in. to 3 in.) Flat & Elongated: Particles meet criteria for both flat and Fine -Grained Gravel: 4.75 mm to 19 mm (No.4 to % in.) elongated Coarse -Grained Sand: 2 mm to 4.75 mm (No.10 to No.4) Medium -Grained Sand: 0.42 mm to 2 mm (No.40 to No.10) RELATIVE PROPORTIONS OF FINES Fine -Grained Sand: 0.075 mm to 0.42 mm (No. 200 to No.40) Descriptive Term % Dry Weight Silt: 0.005 mm to 0.075 mm Trace: < 5% Clay: <0.005 mm With: 5% to 12% Modifier: >12% Page 1 of Mom' fi GENERAL NOTES (Continued) CONSISTENCY OF FINE-GRAINED SOILS MOISTURE CONDITION DESCRIPTION Q„ - TSF N - Blows/foot Consistency Description Criteria Dry: Absence of moisture, dusty, dry to the touch 0 - 0-2 Very Soft Moist: Damp but no visible water 0. 0. 50 -.00 2-4 Soft Wet: Visible free water, usually soil is below water table 0.50-1 4-8 Firm (Medium Stiff) 1.00 - 2.00 8 - 15 Stiff RELATIVE PROPORTIONS OF SAND AND GRAVEL 2.00 - 4.00 15 - 30 Very Stiff Descriptive Term % Dry Weight 4.00 - 8.00 30-50 Hard Trace: < 15% 8.00+ 50+ Very Hard With: 15% to 30% Modifier: >30% STRUCTURE DESCRIPTION Description Criteria Description Criteria Stratified: Alternating layers of varying material or color with Blocky: Cohesive soil that can be broken down into small layers at least'/4-inch (6 mm) thick angular lumps which resist further breakdown Laminated: Alternating layers of varying material or color with Lensed: Inclusion of small pockets of different soils layers less than'/4-inch (6 mm) thick Layer: Inclusion greater than 3 inches thick (75 mm) Fissured: Breaks along definite planes of fracture with little Seam: Inclusion 1/8-inch to 3 inches (3 to 75 mm) thick resistance to fracturing extending through the sample Slickensided: Fracture planes appear polished or glossy, Parting: Inclusion less than 1/8-inch (3 mm) thick sometimes striated SCALE OF RELATIVE ROCK HARDNESS Q„ - TSF Consistency 2.5 - 10 Extremely Soft 10-50 Very Soft 50 - 250 Soft 250 - 525 Medium Hard 525 - 1,050 Moderately Hard 1,050 - 2,600 Hard >2,600 Very Hard ROCK VOIDS Voids Void Diameter Pit <6 mm (<0.25 in) Vug 6 mm to 50 mm (0.25 in to 2 in) Cavity 50 mm to 600 mm (2 in to 24 in) Cave >600 mm (>24 in) ROCK BEDDING THICKNESSES Description Criteria Very Thick Bedded Greater than 3-foot (>1.0 m) Thick Bedded 1-foot to 3-foot (0.3 m to 1.0 m) Medium Bedded 4-inch to 1-foot (0.1 m to 0.3 m) Thin Bedded 1'/4-inch to 4-inch (30 mm to 100 mm) Very Thin Bedded '/z-inch to 1'/4-inch (10 mm to 30 mm) Thickly Laminated 1/8-inch to 1/2-inch (3 mm to 10 mm) Thinly Laminated 1/8-inch or less "paper thin" (<3 mm) GRAIN -SIZED TERMINOLOGY (Typically Sedimentary Rock) Component Size Range Very Coarse Grained >4.76 mm Coarse Grained 2.0 mm - 4.76 mm Medium Grained 0.42 mm - 2.0 mm Fine Grained 0.075 mm - 0.42 mm Very Fine Grained <0.075 mm ROCK QUALITY DESCRIPTION DEGREE OF WEATHERING Rock Mass Description RQD Value Slightly Weathered: Rock generally fresh, joints stained and discoloration Excellent 90 -100 extends into rock up to 25 mm (1 in), open joints may Good 75 - 90 contain clay, core rings under hammer impact. Fair 50-75 Poor 25-50 Weathered: Rock mass is decomposed 50% or less, significant Very Poor Less than 25 portions of the rock show discoloration and weathering effects, cores cannot be broken by hand or scraped by knife. Highly Weathered: Rock mass is more than 50% decomposed, complete discoloration of rock fabric, core may be extremely broken and gives clunk sound when struck by hammer, may be shaved with a knife. Page 2 of 2 SOIL CLASSIFICATION CHART NOTE: DUAL SYMBOLS ARE USED TO INDICATE BORDERLINE SOIL CLASSIFICATIONS MAJOR DIVISIONS SYMBOLS TYPICAL DESCRIPTIONS GRAPH LETTER GRAVEL AND CLEAN GRAVELS �'�'�'� : : GW WELL -GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES GRAVELLY SOILS (LITTLE OR NO FINES) ° �o o �o o DDo D 00 ° °� ° GP POORLY -GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES COARSE GRAINED SOILS MORE THAN 50% OF COARSE GRAVELS WITH FINES ° �° c D c) ° ° c o ° D O ° GM SILTY GRAVELS, GRAVEL - SAND - SILT MIXTURES FRACTION RETAINED ON NO. 4 SIEVE (APPRECIABLE AMOUNT OF FINES) LIE GC CLAYEY GRAVELS, GRAVEL - SAND - CLAY MIXTURES SAND CLEAN SANDS SW WELL -GRADED SANDS, GRAVELLY SANDS, LITTLE OR NO FINES MORE THAN 50% OF MATERIAL IS LARGER THAN NO. 200 SIEVE SIZE AND SANDY SOILS (LITTLE OR NO FINES) SP POORLY -GRADED SANDS, GRAVELLY SAND, LITTLE OR NO FINES o MORE THAN 50% SANDS WITH FINES SM SILTY SANDS, SAND - SILT MIXTURES OF COARSE FRACTION PASSING ON NO. 4 SIEVE (APPRECIABLE AMOUNT OF FINES) v7 SC CLAYEY SANDS, SAND - CLAY MIXTURES INORGANIC SILTS AND VERY FINE ML SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY INORGANIC CLAYS OF LOW TO SILTS FINE GRAINED SOILS AND LIQUID LIMIT CLAYS LESS THAN 50 CL MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY MORE THAN 50% OF MATERIAL IS SMALLER THAN NO. 200 SIEVE MH INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SAND OR SILTY SOILS SIZE SILTS LIQUID LIMIT AND GREATER THAN50 CLAYS CH INORGANIC CLAYS OF HIGH PLASTICITY OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS HIGHLY ORGANIC SOILS .' . ' . ' . ' PT PEAT, HUMUS, SWAMP SOILS WITH HIGH ORGANIC CONTENTS Mom' Lon BORING LOGS Proposed Retail Pet Supply Facility, Dunn, NC PSI Report No. 05111058 March 20, 2022 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-1 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 50.0 ft DRILL RIG: CME 550 While Drilling 7 feet BENCHMARK: N/A DRILLING METHOD: Mud Rotary 1 Upon Completion N/A ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7 Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with bentonite chips upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N ° Q of X Moisture 0 PL t ILL Additional co Q Q E N o za so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp o 2.0 4.0 0 i' TOPSOIL (4 inches) FILL - Loose, Brown, Silty SAND - Moist 1 12 SM 4-5-5 15 ° X Fines = 22.6% N=10 ALLUVIUM - Loose, Gray, Silty, Clayey SAND, slight organic odor - Moist ILL = 19 2 12 C-S 4-4-5 15 ° PL = 13 5 N=9 Fines = 39.1 % ALLUVIUM - Medium Dense, Brown/Gray, 3 12T Silty SAND with Clay and Gravel - Wet SM 4-6-7 N=13 ALLUVIUM - Very Loose, Brown/Gray, o GRAVEL with Sand and Silt - Wet 4 1 2-2-2 ° 10 a GM N=4 ALLUVIUM - Medium Dense, Brown and Gray, Clayey GRAVEL with Sand - Wet 5 8 GC 2-5-12 16 Fines = 14.0% 15 N=17 ALLUVIUM - Medium Dense, Brown and • �' Gray, Well Graded GRAVEL with Sand - Wet 6 14 GW 7-7-8 21 ° X Fines = 4.2% 20 • N=15 COASTAL PLAIN DEPOSIT -Dense to Medium Dense, Gray, Clayey SAND - Moist 7 18 13-16-23 20 ° ILL=30 PL = 18 25 N=39 Fines = 21.6% SC 8 18 4-8-9 ° 30 N=17 SC Continued Next Page Intertek Professional Service Industries, Inc. PROJECT NO.: 05111058 5021-A West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Facility si Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 2 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-1 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 50.0 ft DRILL RIG: CME 550 While Drilling 7 feet BENCHMARK: N/A DRILLING METHOD: Mud Rotary 1 Upon Completion N/A ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7 Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with bentonite chips upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N 0 2e so Remarks � C7 m Cl)0 U o Lu ) � STRENGTH, tsf IL A Qu ))K Qp 0 2.0 4.0 COASTAL PLAIN DEPOSIT -Medium Dense to Dense, Brown/Gray, Clayey SAND - 9 18 Moist 8-8-12 0 35 N=20 10 18 SC 11-14-17 19 X 0 Fines = 12.9% 40 N=31 11 18 6-10-7 0 45 :. N=17 COASTAL PLAIN DEPOSIT -Medium Dense, Gray/Brown, Well Graded SAND - Moist SW 12 18 7-13-12 25 Fines = 4.0% 50 N=25 Boring terminated at 50 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 5021-A West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Facility S I Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 2 of 2 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-2 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 2O.0 ft DRILL RIG: CME 550 While Drilling 12 feet BENCHMARK: N/A DRILLING METHOD: Hollow Stem Auger 1 Upon Completion 12.5 feet ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7 Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with the auger cuttings upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N o za so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp o 2.0 4.0 0 i' TOPSOIL (4 inches) FILL - Medium Dense, Brown, Silty SAND 1 6 with rock fragments - Moist SM 4-7-5 N=12 ALLUVIUM - Loose, Brown and Dark Brown, Clayey SAND - Moist 2 8 SC 4-5-5 5 N=10 ALLUVIUM - Medium Dense, Brown, Clayey 3 6 SAND with Gravel - Moist SC 3-7-9 0 N=16 ALLUVIUM - Soft, Gray, Sandy Lean CLAY - Moist 4 16 6-2-2 0 10 CL N=4 ALLUVIUM - Medium Dense, Dark Brown, Clayey GRAVEL with Sand - Wet 5 14 GC 5-9-11 0 15 N=20 COASTAL PLAIN DEPOSIT -Dense, Gray, Clayey SAND - Moist SC 6 12 4-14-32 0 20 N=46 Boring terminated at 20 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Fac Facility Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) PSI5021-A Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-3 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 2O.0 ft DRILL RIG: CME 550 While Drilling 11 feet BENCHMARK: N/A DRILLING METHOD: Hollow Stem Auger 1 Upon Completion 12 feet ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7 Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with the auger cuttings upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N o za so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp o 2.0 4.0 0 i'. <` TOPSOIL (5 inches) FILL - Medium Dense, Brown, Silty SAND 1 6 with Clay- Moist 10-11-10 0 N=21 SM 2 12 12-12-11 0 5 N=23 ALLUVIUM - Medium Dense, Brown/Tan, Silty SAND with Clay and Gravel - Moist SM 3 8 11-11-4 0 ALLUVIUM - Loose, Dark Brown, Silty N=15 SAND with Clay - Moist to Wet 4 10 SM 2-1-4 0 10 N=5 IF ALLUVIUM - Medium Dense, Gray/Brown, Clayey GRAVEL with Sand - Wet 5 12 GC 3-6-9 0 15 N=15 COASTAL PLAIN DEPOSIT -Medium Dense, Brown/Gray, Clayey SAND - Moist SC A6 12 5-5-6 0 20 N=11 Boring terminated at 20 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Fac Facility Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) PSI5021-A Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-4 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 2O.0 ft DRILL RIG: CME 550 While Drilling 12 feet BENCHMARK: N/A DRILLING METHOD: Hollow Stem Auger 1 Upon Completion 13.5 feet ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7 Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with the auger cuttings upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N o za so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp o 2.0 4.0 0 i' TOPSOIL (3 inches) FILL - Medium Dense, Brown, Silty SAND 1 4 with rock fragments - Moist SM 11-10-6 0 N=16 ALLUVIUM - Loose, Dark Brown, Silty SAND with Clay - Moist 2 8 SM 2-3-2 5 N=5 ALLUVIUM - Medium Dense to Loose, o 3 8 Brown/Gray, GRAVEL with Sand and Silt - 9-5-6 0 Moist GM N=11 a 4 12 2-3-2 0 10 ALLUVIUM - Loose, Dark Brown, Silty Fine N=5 SAND, trace wood fragments - Moist to Wet SM ALLUVIUM - Very Loose, Gray, Silty SAND IF with Gravel - Wet 5 2 SM 3-1-1 0 15 N=2 COASTAL PLAIN DEPOSIT -Medium Dense, Gray/Brown, Clayey SAND - Moist SC 6 14 5-7-9 0 20 N=16 Boring terminated at 20 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Fac Facility Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) PSI5021-A Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-5 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 10.0 ft DRILL RIG: CME 550 While Drilling None BENCHMARK: N/A DRILLING METHOD: Hollow Stem Auger 1 Upon Completion Dry ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7- Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with the auger cuttings upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N o za so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp o 2.0 4.0 0 i' TOPSOIL (4 inches) FILL - Medium Dense, Brown, Silty SAND 1 6 and Rock Fragments - Moist 10-12-10 0 SM N=22 2 10 8-5-5 ALLUVIUM - Loose, Dark Brown, Clayey 5 SAND - Moist SC N=10 ALLUVIUM - Loose, Dark Brown/Gray, 3 6 Clayey SAND, trace roots - Moist SC 2-4-4 N=8 jo ALLUVIUM - Firm, Brown/Gray, Sandy Lean CLAY - Moist to Wet CL 4 8 2-3-2 10 N=5 Boring terminated at 10 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 5021-A West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Facility S I Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 4/29/22 DRILL COMPANY: HPC BORING B-6 DATE COMPLETED: 4/29/22 DRILLER: Cain LOGGED BY: Steege COMPLETION DEPTH 10.0 ft DRILL RIG: CME 550 While Drilling None BENCHMARK: N/A DRILLING METHOD: Hollow Stem Auger 1 Upon Completion Dry ELEVATION: N/A SAMPLING METHOD: 2-in SS, Standard 7- Delay N/A LATITUDE: HAMMER TYPE: Automatic BORING LOCATION: LONGITUDE: EFFICIENCY N/A See Boring Location Plan STATION: N/A OFFSET: N/A REVIEWED BY: AOS REMARKS: Borehole backfilled with the auger cuttings upon completion. STANDARD PENETRATION in o L TEST DATA Q) o 0- o m c o IN in blows/ft OO o J Z a MATERIAL DESCRIPTION N m Q of X Moisture 0 PL t ILL Additional co Q Q E N 0 2e so Remarks Lu ) � STRENGTH, tsf I Qu ))K Qp 0 2.0 4.0 0 TOPSOIL (6 inches) FILL - Medium Dense, Brown, Silty SAND, 1 10 rock fragments - Moist 10-14-14 o N=28 SM 2 10 14-10-10 5 N=20 ALLUVIUM - Loose, Brown, Silty SAND with Clay and Gravel - Moist 3 12 4-5-3 o SM N=8 4 6 2-2-2 0 ALLUVIUM - Very Loose, Dark Brown, Silty SM 10 Fine SAND with Clay - Moist to Wet N=4 Boring terminated at 10 feet. ntertek Professional Service Industries, Inc. PROJECT NO.: 05111058 West W.T. Harris Boulevard PROJECT: Proposed Retail Pet Supply Fac Facility Charlotte, NC 28269 LOCATION: NWQ W Cumberland St (US Hwy 421) PSI5021-A Telephone: (704) 598-2234 and Marlowe Drive Dunn, North Carolina The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1