HomeMy WebLinkAboutSW3221003_Soils/Geotechnical Report_20221011K. Joe Job' n c-:I.s�;�r alrr rlsr 3 J U�ibrvl� R F7and lir ,VG' k 48 {.33 _r1_m- Summey Engineering Associates, PLLC PO Box 968 Asheboro, NC 27203 Wednesday, May 4, 2022 Re: Seasonally High Water Table Evaluation - Rowan County NC Parcel ID 364 059 320 E. Main St. Rockwell, NC Mr. Summey, On April 23, 2022, the soil conditions were evaluated to determine the seasonally high water table within the area of the proposed stormwater BMPs for the property referenced above. This investigation was completed to comply with the requirements set forth in Rule NCAC 15A 02H and parts A2 and C6 of the North Carolina Department of Environmental Quality Stormwater Design Manual. All soil samples were evaluated with a hand auger and sample locations were logged using a Trimble GEO 7x GPS data collector. Identification of the Seasonally Nigh Water Table Determination of the depth to the seasonally high water table is accomplished through field evaluation for soil wetness conditions indicated by the presence of redoximorphic features of chroma 2 or less (Munsell Soil Color Book) either as mottles or matrix color. Colors of chroma 2 or less due to relic minerals from parent material (underlying saprolite and rock), perched water table due to soil texture changes, or anaerobic conditions due to the placement of fill material are not considered as SHWT indicators. Stormwater BMPs such as the planned sand filter for this project site must be designed to provide at least two feet of separation between the SHWT and the lowest elevation of the bottom of the BMPs (with consideration for an additional 6" deducted for the movement of water within the capillary fringe above the SHWT). The following figures include deduction for the capillary fringe. No SHWT was encountered under the proposed BMP location to elevation 743' (approximately 10' below natural ground surface). K. Joe Johnson, LSS (336) 953-0763 kjoejohnsonsodsggmad can K. JO` AA Wrr NC,'Lrceiaverl Sp�.S�cic/�tist 3611 Qet0 L"tr, R;t Fr�trkli+T'vi11i� 1VCdr,��R Below is a summary chart of the observations within the proposed stormwater BMP devices: BMP # 1 Boring # SHWT Munsell Color 1 NO SHWT @ 10' BGS or elevation 745' N/A 2 NO SHWT @ 10' BGS or elevation 743' N/A I am pleased to be of service in this matter and will be available to provide further assistance in the future if necessary, to aid in the successful completion of this project. Sincerely, ltier Joe Johnson, LSS v EOIL SCf� C So J�y s K. Joe Johnson, LSS (336) 953-0763 kjoejohnsonsoils agnrail.com dYl! F,-lp� FD SOIL ODE alb Z L-6:03NOZ r. V13 NHSf1S / )V Nli6VN Boring#1 `nJ • `0 " �y i Elevation Approx. 755' QF�� I,i ! Depth of Boring 10' BGS ;"�", eb SHWT Not Encountered �Ow. G� / Assumed SHWT -@ < 745' Elevation 12 xwn l-21:03NOZ L8l/6�� l :J3N 0330 I�b Boring #2 Elevation Approx. 753' ru !f f 1 i' �. — ,kl, uuw 3aes,xw ,ryc.w.. Depth of Boring 10' BGS } !`•—f _J`"� , ! �, r r 1 • r--� --. SHWT Not Encountered i .1 1 o i Assumed SHWT < 743' Elevation + �., r; 1 l + aat s.a x w.ce t��� 5 Foci. '� a ml zwANx ! + s� _4-0 1 r r j�ir 11 ! Z-8:0JNOZ �0 Z92/0LC L :J36 0330 ~- 331 NOl�l0 b3M3�18 NNV .13S�3N H13dS0IH . v J _--------- f'f 111 "r�tl IIJ J � I � 00 ---. 1S N1bW 3 •—. o•--�—. •—• - Legend: 0 Soil Boring Location—•- '1 inch = 5� feet Rockwell ABC Stare Project „r„•, m.����,�,b,,,�„�,,,,��,.� �+ �w �w ur w..inpm.M I I. d --.:+ N D s W 32Ei East Main 5i- Rockwell, NC inipnn.enr,npnogeor.i.nd.uwey.�nanwnonpe�weu r ieq� er,a..mnn�wn m.r�., v..ufr Hvamam rec+sm. Base Map: Summey Engineering Associates. PLLC Rowan County Parcel I❑ # 364 059 �•.m n. mn+-.nd nmi nnrm n�way.wv.y .ccv.p