Loading...
HomeMy WebLinkAboutSW5220601_Plansheet - Set_20221003�S 0 R2� tiy�A SITE STptiF �o MEMORIAL DR US 64 / 11TH ST �Z on SILER CITY ➢ mo VICINITY MAP N.T.S. CIVIL PLANS FOR 2S7S HAMP STONE ROAD SILER CITY - CHATHAM COUNTY - NORTH CAROLINA PROJECT NO.: E-543 7 SEPTEMBER 2022 ,,.�....�IIN.,,,,, o•��N ARo�'. i EAL 26447 ;k SUM�`�`.``�. ,-5ummey �r-��ineerin�A,5,50ciatc,5,PLLC L r-rgine ering - L a n dr1a n ning - Co n,5 u Iting P.O. fjox �0/"8 Asheboro, NC 2J209- Fh: C336) 328-0902 fx: (336) 328-0,�922 email. inro0summeyenginccring. com # SHEET INDEX C-0 COVER SHEET C-1 GENERAL NOTES EX-1 SITE AMENDMENT PLAN C-2 EXISTING CONDITIONS AND DEMO PLAN C-3A OVERALL SITE C-313 SITE PLAN C-4 EROSION CONTROL PHASE 1 PLAN C-4A EROSION CONTROL PHASE 2 PLAN C-5 GRADING PLAN C-5A SPOT ELEVATION PLAN C-6 PAVING PLAN C-7 LANDSCAPE PLANE C-8 STANDARD DETAILS C-9 EROSION CONTROL DETAILS C-10 EROSION CONTROL DETIALS C-11 SANITARY SEWER DETAILS C-12 WATER DETAILS GENERAL SITE NOTES: UTILITY NOTES: (IF APPLICABLE) 1. THE INFORMATION SHOWN HEREIN WAS TAKEN FROM BOUNDARY AND TOPOGRAPHIC SURVEY PROVIDED BY: SURVEY CAROLINA 154 S FAYETTEVILLE STREET, ASHEBORO, NC PHONE: (336) 460-0216 AND CHATHAM COUNTY GIS. 1. UTILITY INFORMATION SHOWN HEREON WAS OBTAINED FROM THE BEST AVAILABLE SOURCE AND MAY OR MAY NOT BE EITHER ACCURATE OR COMPLETE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXACT LOCATIONS OF EXISTING UTILITIES AND IS RESPONSIBLE FOR ANY DAMAGE TO ANY UTILITIES, EITHER 2. THE LOCATIONS OF ALL UTILITIES SHOWN ON THESE PLANS ARE BASED ON THE AVAILABLE INFORMATION. THE CONTRACTOR PUBLIC OR PRIVATE, SHOWN HEREON OR NOT SHOWN HEREON. ANY REPAIRS SHALL BE DONE TO THE SATISFACTION OF THE APPROPRIATE UTILITY COMPANY. SHALL VERIFY THE EXACT LOCATION OF UTILITIES WITH THE UTILITY OWNERS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. THE GENERAL CONTRACTOR SHALL CONFIRM ALL NEW UTILITY TAP LOCATIONS WITH THE UTILITY OWNERS. ALL FEES SHALL BE THE RESPONSIBILITY OF 3. ALL HANDICAP SITE FEATURES SHALL BE CONSTRUCTED TO MEET ALL FEDERAL, STATE AND LOCAL CODES. CONTRACTOR OR GENERAL CONTRACTOR. 4. ANY DISCREPANCY IN THIS PLAN, ARCHITECTURAL PLANS, AND/OR ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE 3. SEE ELECTRICAL ENGINEERING SITE PLAN FOR LOCATION OF ALL SITE LIGHTING AND REQUIREMENTS ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, 4. ALL NEW LOT LIGHTS AND THE MAIN IDENTIFICATION SIGN SHALL HAVE A MINIMUM 10 FEET CLEARANCE FROM ALL OVERHEAD UTILITIES. EASEMENTS, AND DIMENSIONS SHOWN HEREIN BEFORE BEGINNING CONSTRUCTION. 5. GENERAL CONTRACTOR IS RESPONSIBLE FOR PERMITS AND/OR APPROVALS NECESSARY FOR ANY WORK IN ROADWAY OR RIGHT-OF-WAY. 5. THE CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES, AND R.O.W.'S. PUBLIC OR PRIVATE, PRIOR TO 6. MINIMUM COVER FOR CONDUITS SHALL BE 36" UNLESS OTHERWISE SHOWN OR NOTED IN THESE PLANS. WORKING IN THESE AREAS. 7. ALL MANHOLES, VALVES, AND MONUMENT FRAMES SHALL BE SET TO FINISH GRADE AFTER PAVING. 6. ACCESS TO UTILITIES, FIRE HYDRANTS, STREET LIGHTING, ET, SHALL REMAIN UNDISTURBED, UNLESS COORDINATED WITH 8. THE CONTRACTOR SHALL COMPLY WITH THE RULES AND REGULATIONS OF THE STATE CONSTRUCTION SAFETY ORDERS. TRENCHES SHALL BE SHORED IN RESPECTIVE UTILITY. ACCORDANCE WITH OSHA. 7. DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 9. THE MINIMUM SLOPE FOR SANITARY SEWER LINES SHALL BE AS FOLLOWS: 1) 1 /4"/FT FOR 4" LINES AND 2) 1 /8"/FT FOR 6" LINES. 6" CLEANOUTS SHALL BE 8. THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE TO CONSTRUCTION PLACED AT 75' INTERVALS. 4" CLEANOUTS SHALL BE PLACED AT 50' INTERVALS OPERATIONS. ALL STREET SURFACES, DRIVEWAYS, CULVERTS, CURBS AND GUTTERS, ROADSIDE DRAINAGE DITCHES, AND 10. ALL SEWER LINES SHALL HAVE A FINAL COVER DEPTH 4'-0 IN NON -TRAFFIC AREAS AND 5-0 MINIMUM IN TRAFFIC AREAS UNLESS SPECIFICALLY NOTED OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MATTER AS A RESULT OF CONSTRUCTION SHALL BE OTHERWISE ON THE PLANS. REPLACED OR REPAIRED IN ACCORDANCE WITH THE SPECIFICATIONS 11. CABLE TV SERVICE ROUTING IS NOT PART OF THIS PLAN, CONTRACTOR TO COORDINATE WITH CABLE COMPANY. 9. ALL PERMITS RELATIVE TO PROJECT MUST BE OBTAINED PRIOR TO CONSTRUCTION. ALL CONSTRUCTION TO BE IN 12. EXISTING MANHOLES SHOULD BE FIELD VERIFIED FOR RIMS AND INVERTS. ACCORDANCE WITH PERMITS ISSUED AND APPLICABLE TO STATE, COUNTY, AND LOCAL CODES. 13. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL INSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC. THAT MAY BE REQUIRED. 10. THE CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALL EXISTING 14. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THIS CONSTRUCTION MEANS/METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. UTILITIES IS NOT NECESSARILY SHOWN ON PLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THE CONTRACTOR ON HIS 15. OCCUPATIONAL HEALTH AND SAFETY ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL INITIATIVE AND AT NO EXTRA COST SHALL HAVE LOCATED ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. NO EXCAVATIONS EXCEEDING 5 FEET IN DEPTH. CLAIMS FOR DAMAGES OR EXTRA COMPENSATION SHALL ACCRUE TO THE CONTRACTOR FROM THE PRESENCE OF ITEMS SUCH 16. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. AS PIPE OR OTHER OBSTRUCTIONS OR FROM ANY DELAY DUE TO REMOVAL OR REARRANGEMENT OF THE SAME. THE 17. CONTRACTOR SHALL MAINTAIN AN "AS BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE DUE TO UNDERGROUND STRUCTURES. CONTRACTOR SHALL BE GIVEN TO THE OWNER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE ENGINEER. RESPONSIBLE FOR CONTACTING ALL NONSUBSCRIBING UTILITIES. THE CONTRACTOR(S) SHALL CALL 811 FOR ASSISTANCE IN 18. WATER PIPING SHALL BE CONNECTED TO BUILDING STUBS, VERIFY LOCATIONS PRIOR TO BEGINNING WATER PIPE INSTALLATION. LOCATING EXISTING UTILITIES. CALL AT LEAST 48 HOURS PRIOR TO ANY DIGGING. 19. WASTE PIPING SHALL BE CONNECTED TO BUILDING STUBS, VERIFY LOCATIONS AND INVERTS PRIOR TO BEGINNING ANY WASTE PIPE INSTALLATION. 11. SEEDING TO BE INSTALLED TO NCDEQ REQUIREMENT & STANDARD PRACTICES. 20. ALL UTILITY CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LOCAL MUNICIPALITY PUBLIC WORKS AND CROSS CONNECTION CONTROL, REGULATIONS AND 12. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND STANDARDS. APPROVALS HAVE BEEN OBTAINED. NO CONSTRUCTION OR FABRICATION OF ANY ITEM SHALL BEGIN UNTIL THE CONTRACTOR 21. SITE UTILITY CONTRACTOR TO PROVIDE WATER AND SANITARY SEWER TO WITHIN 5 FEET OF THE BUILDING, CONTRACTOR SHALL COORDINATE SITE PLAN HAS RECEIVED ALL PLANS AND ANY OTHER DOCUMENTATION FROM ALL OF THE PERMITTING AND ANY OTHER REGULATORY CONNECTIONS WITH THE ARCHITECTURAL BUILDING PLANS. AUTHORITIES. FAILURE OF THE CONTRACTOR TO FOLLOW THIS PROCEDURE SHALL CAUSE THE CONTRACTOR TO ASSUME FULL 22. SANITARY CLEANOUTS SHALL BE PLACED NO MORE THAN 75 FEET APART. CLEAN OUTS LOCATED IN PAVEMENT AREAS SHALL HAVE A HEAVY DUTY RESPONSIBILITY FOR ANY SUBSEQUENT MODIFICATION OF THE WORK MANDATED BY ANY REGULATORY AUTHORITY. TRAFFIC RATED CONSTRUCTION. 13. VISIT SITE AND BRING TO THE ENGINEER'S ATTENTION IN WRITING ANY PROBLEMS OR DISCREPANCIES WITH THE SITE OR 23. CONNECTION OF SANITARY SEWER SERVICE TO AN EXISTING MANHOLE SHALL COMPLY WITH THE LOCAL MUNICIPALITY PUBLIC WORKS STANDARDS, INCLUDING: CORE DRILL FOR OPENING INTO MANHOLE AND INSTALL WITH FLEXIBLE BOOT. IF PAVEMENT CUT IS REQUIRED, CONTRACTOR SHALL PATCH PAVEMENT WITH A PROJECT PRIOR TO CONSTRUCTION. SECTION TO MATCH EXISTING PAVEMENT 14. CHECK ALL "VERIFY" DIMENSIONS NOTED ON PLANS. REPORT ANY DISCREPANCIES TO THE ENGINEER IN WRITING PRIOR TO 24. ALL WORK SHALL BE GOVERNED BY THE LATEST EDITIONS OF THE STATE MECHANICAL, PLUMBING, ELECTRICAL, FIRE PROTECTION, BUILDING CODE, ENERGY ANY FURTHER CONSTRUCTION. CONSERVATION, HANDICAPPED ACCESSIBILITY, NATIONAL ELECTRICAL CODES, AND NATIONAL FIRE PROTECTION ASSOCIATION CODES AS APPLICABLE AND AS ADOPTED 15. USE THE ARCHITECT'S DRAWINGS FOR BUILDING DIMENSIONS. BY THE AUTHORITIES HAVING JURISDICTION AND LATEST VERSION OF NC DOT POLICIES & PROCEDURES FOR ACCOMMODATING UTILITIES ON HIGHWAY RIGHTS -OF -WAY. 25. LOCATIONS OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE APPROXIMATE OR SCHEMATIC. THE LOCATIONS ARE BASED ON ACTUAL FIELD SURVEYS AND AVAILABLE RECORDS, CONTRACTOR SHALL FIELD VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AND UNDERGROUND STRUCTURES AND VERIFY REQUIRE COVER AND CLEARANCES PRIOR TO CONSTRUCTION AND REPORT ANY CONFLICTS TO THE ENGINEER. 26. CONTRACTOR SHALL CALL 811 AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENTLY. CONTRACTOR NOTES: 1. ALL DIMENSIONS AND RADII ARE OUTSIDE FACE OF BUILDING OR TO FACE OF CURB, OR TO THE CENTER OF STRUCTURES SUCH AS INLETS, SIGN POSTS, ETC., UNLESS OTHERWISE NOTED. 2. CONTACT ENGINEER FOR OBSERVATION OF CONSTRUCTION RELATED TO REQUIRED FEDERAL, STATE, OR LOCAL CERTIFICATIONS INCLUDING BUT NOT LIMITED TO PROOF ROLL AND ASPHALT PLACEMENT. PROVIDE 24 HOUR NOTICE TO ENGINEER FOR REQUIRED CONSTRUCTION OBSERVATION RELATED TO CERTIFICATION OF ROADWAY, WATER SYSTEM, PAVEMENT, ETC. 3. KEEP ALL PLANTING AND GRASS AREAS FREE OF DEBRIS, STONES, CONSTRUCTION MATERIALS, ETC., RESPONSIBLE FOR NOT DAMAGING EXISTING PLANTING TO REMAIN. 4. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND AVOIDING ALL UNDERGROUND UTILITIES WHETHER SHOWN ON THE SITE PLAN OR NOT. THOSE SHOWN ARE BASED ON THE SURVEY PROVIDED AND MAY NOT BE ALL INCLUSIVE. CONTACT UTILITY LOCATION SERVICE OR OTHER APPROPRIATE UTILITY LOCATION SERVICE FOR UTILITY IDENTIFICATION PRIOR TO ANY WORK. CONTRACTOR TO PROTECT ALL UTILITIES TO REMAIN - TYPICAL. CONTACT ALL UTILITY COMPANIES TO INSURE THE UTILITIES ARE SHUT DOWN PRIOR TO THE START OF ANY DEMOLITION AND/ OR SITE WORK. 5. PATCH / REPAIR STREETS, STRUCTURES, ETC. AS NECESSARY AFTER CONNECTION OF PROPOSED UTILITIES. 6. SEE PLAN SET FOR PROPOSED GRADES AND EROSION CONTROL. 7. CIVIL/SITE CONTRACTOR SHALL FIELD VERIFY VERTICAL AND HORIZONTAL LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. CIVIL/SITE CONTRACTOR SHALL SCHEDULE A PRE -CONSTRUCTION CONFERENCE WITH THE LOCAL MUNICIPALITY AND ARCHITECT PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL CALL 811 5 WORKING DAYS HOURS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. 8. CONTRACTOR SHALL NOTIFY THE LOCAL MUNICIPALITY PUBLIC WORKS PRIOR TO ANY CONSTRUCTION ON STREET RIGHTS -OF -WAY 336-626-1234 9. ANY CONSTRUCTION WITHIN THE LOCAL MUNICIPALITY RIGHTS -OF WAY ARE TO BE IN ACCORDANCE WITH THE LOCAL MUNICIPALITY STANDARDS AND SPECIFICATIONS REGARDING MATERIALS, INSTALLATION, AND TESTING, UNLESS OTHERWISE IN THE CONTRACT DOCUMENTS. ANY CONSTRUCTION WITHIN THE RIGHT-OF-WAY SHALL BE PROTECTED WITH SIGNAGE AND TRAFFIC SAFETY DEVICES IN ACCORDANCE WITH THE NORTH CAROLINA STANDARDS AND GUIDELINES ALSO THE CONTRACTOR SHALL HAVE "UTILITY WORK AHEAD" SIGNS LOCATED AT ALL LOCATIONS WHEN ENTERING THE RIGHTS -OF -WAY. 27. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES IN COORDINATION WITH THE APPROPRIATE UTILITY, AGENCY, OR COMPANY. 28. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE ACTUAL LOCATION AND AVAILABILITY OF ALL EXISTING AND PROPOSED UTILITIES IN THE FIELD PRIOR TO GROUND BREAKING. 29. ALL UTILITIES MUST BE LOCATED UNDERGROUND AND COORDINATED WITH THE LOCAL MUNICIPALITY OR LOCAL UTILITIY COMPANY. TOWN OF SILER CITY NOTES: 1. CALL 811 BEFORE DIGGING TO LOCATE UNDERGROUND UTILITIES* 2. FOLLOW APPENDIX E GUIDE TO LANDSCAPING FOR ALL TREE AND SHRUB INSTALLATION 3. ALL ON SITE DRIVEWAYS, SIDEWALKS, PARKING LOTS, AND ENTRANCES/EXITS TO BUILDINGS SHALL BE SUFFICIENTLY AND ADEQUATELY LIGHTED TO ENSURE THE SECURITY OF PROPERTY/BUILDINGS AND THE SAFETY OF PERSONS. 4. ON SITE LIGHTING SHALL NOT UNNECESSARILY ILLUMINATE ANY OTHER LOT OR PUBLIC STREET. 5. TO THE EXTENT PRACTICABLE, THIS DEVELOPMENT SHALL CONFORM TO THE NATURAL CONTOURS OF THE LAND AND NATURAL AND PREEXISTING MANMADE DRAINAGE WAYS SHALL REMAIN UNDISTURBED. 6. THIS DEVELOPMENT MUST BE PROVIDED WITH A DRAINAGE SYSTEM THAT IS ADEQUATE TO PREVENT THE UNDUE RETENTION OF SURFACE WATER ON THE DEVELOPMENT SITE. 7. NO SURFACE WATER MAY BE CHANNELED OR DIRECTED INTO A SANITARY SEWER.* 8. WHENEVER PRACTICABLE, THE DRAINAGE SYSTEM OF THIS DEVELOPMENT SHALL COORDINATE WITH AND CONNECT TO THE DRAINAGE SYSTEMS OR DRAINAGE WAYS ON SURROUNDING PROPERTIES OR STREETS. 9. CONSTRUCTION SPECIFICATIONS FOR DRAINAGE SWALES, CURBS AND GUTTERS, AND STORM DRAINS ARE CONTAINED IN APPENDIX C. 10. THIS DEVELOPMENT SHALL BE CONSTRUCTED AND MAINTAINED SO THAT ADJACENT PROPERTIES ARE NOT UNREASONABLY BURDENED WITH SURFACE WATERS AS A RESULT OF SUCH DEVELOPMENTS* 11. NO DEVELOPMENT MAY BE CONSTRUCTED OR MAINTAINED SO THAT SUCH DEVELOPMENT UNREASONABLY IMPEDES THE NATURAL FLOW OF WATER FROM HIGHER ADJACENT PROPERTIES ACROSS SUCH DEVELOPMENT, THEREBY UNREASONABLY CAUSING SUBSTANTIAL DAMAGE TO SUCH HIGHER ADJACENT PROPERTIES* 12. NO DEVELOPMENT MAY BE CONSTRUCTED OR MAINTAINED SO THAT SURFACE WATERS FROM SUCH DEVELOPMENT ARE UNREASONABLY COLLECTED AND CHANNELED ONTO LOWER ADJACENT PROPERTIES AT SUCH LOCATIONS OR AT SUCH VOLUMES AS TO CAUSE SUBSTANTIAL DAMAGE TO SUCH LOWER ADJACENT PROPERTIES. 13. STORMWATER CONTROL FACILITIES SHALL BE MAINTAINED BY THE DEVELOPER. 14. ALL SIGNS REQUIRE SIGN PERMIT APPROVAL PRIOR TO INSTALLATION 15. ANY VARIATION TO THE APPROVED PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE TOWN OF SILER CITY DIRECTOR OF PLANNING AND COMMUNITY DEVELOPMENT FOR EVALUATION AND REVISED PLAN SUBMITTED FOR REVIEW AND APPROVAL. 16. VEHICLE ACCOMMODATION AREAS OF ALL DEVELOPMENTS SHALL BE DESIGNED SO THAT SANITATION, EMERGENCY, AND OTHER PUBLIC SERVICE VEHICLES CAN SERVE SUCH DEVELOPMENTS WITHOUT THE NECESSITY OF BACKING UNREASONABLE DISTANCES OR MAKING OTHER DANGEROUS OR HAZARDOUS TURNING MOVEMENTS. 17. EVERY VEHICLE ACCOMMODATION AREA SHALL BE DESIGNED SO THAT VEHICLES CANNOT EXTEND BEYOND THE PERIMETER OF SUCH AREA ONTO ADJACENT PROPERTIES OR PUBLIC RIGHTS -OF -WAY. SUCH AREAS SHALL ALSO BE DESIGNED SO THAT VEHICLES DO NOT EXTEND OVER SIDEWALKS OR TEND TO BUMP AGAINST OR DAMAGE ANY WALL, VEGETATION, OR OTHER OBSTRUCTION. 18. CIRCULATION AREAS SHALL BE DESIGNED SO THAT VEHICLES CAN PROCEED SAFELY WITHOUT POSING A DANGER TO PEDESTRIANS OR OTHER VEHICLES AND WITHOUT INTERFERING WITH PARKING AREAS. 19. VEHICLE ACCOMMODATION AREA SURFACES SHALL BE KEPT IN GOOD CONDITION (FREE FROM POTHOLES, EROSION, DUST, ETC.). 20. NO OBSTRUCTIONS ARE ALLOWED WITHIN THE 10'X70' SIGHT DISTANCE TRIANGLES LOCATED AT DRIVEWAY EXITS 21. VEGETATIVE BUFFERS ARE TO BE LEFT IN THEIR NATURAL STATE AND UNDISTURBED. 22. PRIOR TO ANY FINAL PLANNING APPROVAL: I. SUBMIT ACTUAL AS -BUILT PLAN FOR ALL STORMWATER MANAGEMENT FACILITIES OR PRACTICES AFTER FINAL CONSTRUCTION COMPLETE* II. EXECUTE AND RECORD WITH THE REGISTER OF DEEDS A STORMWATER MANAGEMENT FACILITY OPERATION AND MAINTENANCE AGREEMENT PER§249.* III. SUBMIT WRITTEN FINAL INSPECTION APPROVAL FOR DRIVEWAY AND ENCROACHMENTS FROM NCDOT* IV. WHENEVER A DEVELOPER INSTALLS ANY PUBLIC UTILITY LINE, THE DEVELOPER SHALL AFTER INSTALLATION IS COMPLETE, AND BEFORE ACCEPTANCE OF ANY WATER OR SEWER LINE, FURNISH THE TOWN WITH A COPY OF AN AS -BUILT DRAWING THAT SHOWS THE EXACT LOCATION OF SUCH UTILITY LINES. V. SUBMIT WRITTEN FINAL INSPECTION APPROVAL FOR PUBLIC WATER AND SEWER UTILITY INSTALLATION FROM TOWN PUBLIC WORKS & UTILITIES DIRECTOR* VI. SUBMIT VOLUNTARY ANNEXATION PETITION PER UTILITY EXTENSION POLICY 23. OBTAIN FINAL ZONING INSPECTION APPROVAL PRIOR TO USE/OCCUPANCY 24. ALL TREE AND SHRUB INSTALLATION SHALL BE IN COMPLIANCE WITH APPENDIX E OF THE UDO. 25. PARKING SPACES IN AREAS SURFACED IN ACCORDANCE WITH CONCRETE/ASPHALT SHALL BE APPROPRIATELY DEMARCATED WITH PAINTED LINES OR OTHER MARKINGS. 26. ALL SIGNS SHALL BE IN COMPLIANCE WITH ARTICLE 18 OF THE UDO 27. NC EROSION LAWS ARE ADMINISTERED AND ENFORCED BY NCDEQ* 28. APPLICABLE BUILDING, ELECTRICAL, PLUMBING, AND HVAC CODES ARE ADMINISTERED, PERMITTED, AND ENFORCED BY THE CHATHAM COUNTY CENTRAL PERMITS AND INSPECTIONS DEPARTMENT* 29. APPLICABLE FIRE CODES ARE ADMINISTERED, PERMITTED, AND ENFORCED BY THE CHATHAM COUNTY FIRE MARSHALL* 30. STREAM DISTURBANCE APPROVAL IS REQUIRED FROM NCDEQ AND USACOE* 31. CONTACT COUNTY WELL AND SEPTIC, REQUIRES A SEPTIC SYSTEM ABANDONMENT PERMIT FOR THE AFFECTED SYSTEM AND SETBACK COMPLIANCE THROUGH ENVIRONMENTAL HEALTH. 32. IF THERE IS NO CONNECTION TO CITY SEWER, THEN THE PROJECT MAY REQUIRE A SEPTIC EXPANSION C A 0 � � AL9 26447 q-2q•z c FNGINE��y��' _iit `j 4. r 0 N o Q " � v lu m N N N N N o z � Q � WLLI U ::� W O � uj i U o2j U W a' U z 0 W J Z UJ W xp X Lu U oC Lu �� ul Zin a a W a N N N N N N N N N N N N y O o0 N O� � � � O O O O O O Zo QccUQ W LL X V Z T J O y U 2 ¢O � O � Z L� I� Lu z cz N U W ca Q >__ L ,W V � N U Z v W O V O z 0 N s � aT hi 3 m v Z Sheet No. X�STNG HURCH O \ 634.5 SS S / 1 STORY FRAME BUILDING TO REMAIN / APPROXIMATE LOCATION OF EXISTING SEPTIC / TANK LOCATION OF EXISTING SEPTIC / TANK LINES TO REMAIN - PER FIELD SURVEY / N `\ ssCIS \ SS \ / S / I / U' / ,,---- SS __— / SS / SS i / 41 EXISTING TREELINE (TYP.) U) 61 O � / l \ \ �0 S SC- CIS�j / 5 15 CC, S`� / EXISTING SEPTIC TANK TO BE ABANDONED - LOCATION PER FIELD SURVEY Oak PROPOSED TREELINE (TYP.) DEMO TREELINE (TYP.) CLEAR AND GRUB AREA (TYP.) ADJOINING PROPERTY LINE (TYP.) 1: FA61rP►LeZily/: I:T.12nj gMM6Wpi,1 PROPERTY LINE (TYP.) LIMITS OF CONSTRUCTION (TYP.) * /X SITE ST�tiF �o MEMORIAL DR US 64 / 11 TH ST VICINITY MAP NOT TO SCALE DRAWING LEGEND ou ou ou O _SS ss — SILER CITY CLEAR AND GRUB AREA PROPERTY LINE ADJOINING PROPERTY LINE INTERNAL PROPERTY LINE OVERHEAD UTILITY EXISTING UTILITY POLE EXISTING SANITARY SEWER MANHOLE EXISTING SANITARY SEWER LINE SETBACK LINES EXISTING FIRE HYDRANT PROPOSED SANITARY SEWER MANHOLE EXISTING WATER LINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR LIMITS OF CONSTRUCTION PROPOSED TREELINE EXISTING TREELINE DEMO TREELINE EXISTING CONDITION NOTES: 1. PARCEL BOUNDARY INFORMATION SHOWN PER FIELD SURVEY OBTAINED FROM SURVEY CAROLINA, PLLC 2. TOPOGRAPHIC DATA PER FIELD SURVEY PERFORMED BY SURVAY CAROLINA, PLLC AND NC ONE MAP CONTOURS. 3. EXISTING SANITARY SEWER LOCATIONS HAVE BEEN SHOWN PER INFO RECEIVED FROM SILER CITY PUBLIC WORKS DEPARTMENT AND SURVEY CAROLINA, PLLC. 4. EXISTING BUILDINGS, AND ROADWAYS HAVE BEEN ESTIMATED PER AERIAL IMAGERY AND FIELD SURVEY. 5. EXISTING SEPTIC SYSTEM TO BE ABANDONED PER CHATHAM COUNTY ENVIRONMENTAL HEALTH STANDARDS AND PERMITTING. EXISTING SEPTIC TANK TO BE ABANDONED SHALL BE PUMPED, CRUSHED AND FILLED. SEWER SERVICE TO BE CONNECTED TO THE EXISTING MUNICIPAL SEWER SERVICE CONNECTION PRIOR TO SEPTIC TANK ABANDONMENT. GRAPHIC SCALE 30 0 15 30 60 240 ( IN FEET ) 1 inch = 30 ft. c� Z2z _0> 0� OWNER: COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN CAR S / 1 AL 26447 4-24-Z7— �N G I N �i hh^^ �J -� x�j \� Q� r .o NNNNNo m Z Lu Q Fes- w �=OWZ�w ca o Lu O Z O Z � Q cy Ua�SuwoC v w pvw ac Z�LQ -r Z d 1_ U in � p v, � w U ac VpNwWa.Zwl z Lu Lu a a N N N N N N N N N N N N O 01 N N p O O O O O O d Z QooUpww V z � � T Z O y J O � � 2 Lu Z CL � z O W � = >-- L Q z I— O `V V z ~ ~ V W � N W 0 V O z O N s \ m gS ai 3 a v O Z o o Sheet No. I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I / CL CO����/ / / / F W W L o r0 �a a 97 P7 � I F / w CD '6Z �w \ W \ W 29.663 ACRES O W Q. a Lr OVERALL SITE NOTE: 0 THIS SHEET IS SHOWN PER FIELD SURVEY INFORMATION RECEIVED �0 FROM SURVEY CAROLINA PLLC DATED 05-19-2022. �^ pnoo IIoxH I � Z=L �SS \\� W I W M X � / I LL.l o � \ N / �I� ssv `� -fi8_t'-------------M'mr--------�£Z6---- sl!W/7APO ulpasodoad ssCD - / 9d7 3.90�Z1o60N 967 - - - _ _ �-11 "E------------------- _ _ _ z W W 90,Z6o�0 N W 3 ,90,Z10l0 N 3 „90,Z6oI,0 N W 7# O do;n0 pasodoad 3 ,-90,Z 60 60 N - a c~!� W W W W s iu,�i � i -- x 'w DRAWING LEGEND 7 Z7 M/8 , 09 an!a(7 aassa,Mi CL , W dimits CL proposed In Gity �,�q � ed OUt of City limits WFrOp°s LINE BEARING DISTANCE L 1 N 74 001 '41 " E 28.00' L2 N 01039'20" E 32.74' L3 N 01039'20" E 30.15' L4 N 0204758" E 25.12' L5 N 01052'31 " E 10.77' L6 N 73053'02" E 31.93' L 7 S 79 04925" W 34.86' L8 S 4004847" E 60.01' L9 S 50002'24" W 8.46' L 10 S 59006'14" W 20.29' L 11 S 46041'31 " E 20.05' L 12 S 84 004'38" W 61.11 ' L 13 N 01013'03" E 94.80' L 14 S 0004348" E 32.33' L 15 N 01012'06" E 59.98' L 16 N 01012'06" E 44.011 CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE Cl 169.12' 62.28' 61.93' N 63 025'04" E 21006'01 " C2 169.12' 90.51 ' 89.43' N 37050'35" E 3003945" C3 169.12' 57.53' 57.25' N 12 03435" E 19 02922" C4 603.68' 56.83' 56.81' N 00042'40" E 502338" C5 493.77' 126.84' 126.49' S 56012'43" W 14043'05" C6 45.00' 96.27' 78.93' S 61040'00" W 12203427" C7 35.00' 36.72' 35.06' S 28051 '47" E 60006'48" - ou ou ss ss ss • W W W .................................. PROPERTY LINE ADJOINING PROPERTY LINE OVERHEAD UTILITY EXISTING UTILITY POLE EXISTING SANITARY SEWER MANH EXISTING SANITARY SEWER LINE SETBACK LINES EXISTING FIRE HYDRANT PROPOSED SANITARY SEWER MAI` EXISTING WATER LINE LIMITS OF CONSTRUCTION PROPOSED TREELINE EXISTING TREELINE GRAPHIC SCALE 80' 0 40' 80' 160' 240' NAD 83 GRID NORTH ( IN FEET ) 1 inch = 80' ft. COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN C A R S S /p .• • 1 � 2644747 0 y 4"ZQ'ZZ c •* FN G I CA- S UMW` ��•�• nZ7 �Uj t-k Z Il) N N N N N m D Z 00 7 13 �nWO�zO oz�o,o� WQW U Zd1U Cf- J W 0- Z U a cc ccW W 0- N N (N N N N N N N N N N o 0 0 0 0 0 d Z QanUaWu- V Z J O V °� V O � � z j w � Q � o 2 O _ N U E V w O V O 0 s m m +� � a Y a) O Sheet No. i STING 1 1 FFI / / / / / / \\\\\ EXISTING MSTING.'.�HURC;HO 634.5 (Est.) aLn Ln / SS � SS//PROPOSED 4" PVC SANITARY SS SEWER SERVICE N SS / S PROPOSED CONC. PAD 5 � N SS / PROPOSED 4" PVC Y SS/ CONNECT PROPOSED 4" PVC TO EXISTING 6" SERVICE 4, ff-s ED 4" PVC SANITARY SEWER SERVICE I I I I I VERIFY WATER LINE MATERIAL, SIZE, AND LOCATION WITH PLUMBING PLANS PROPOSED CONC. SIDEWALK I1:Zd1��9��Zd�P►L�11�7 EXISTING 6" SANITARY SEWER SERVICE EXISTING PAVED PARKING TOWN OF SILER CITY NOTES: \ 1. CALL 811 BEFORE DIGGING TO LOCATE UNDERGROUND UTILITIES* 2. FOLLOW APPENDIX E GUIDE TO LANDSCAPING FOR ALL TREE AND SHRUB INSTALLATION \ 3. ALL ON SITE DRIVEWAYS, SIDEWALKS, PARKING LOTS, AND ENTRANCES/EXITS TO BUILDINGS SHALL BE SUFFICIENTLY AND ADEQUATELY LIGHTED TO ENSURE THE SECURITY OF PROPERTY/BUILDINGS AND THE SAFETY OF PERSONS. 4. ON SITE LIGHTING SHALL NOT UNNECESSARILY ILLUMINATE ANY OTHER LOT OR PUBLIC STREET. 5. TO THE EXTENT PRACTICABLE, THIS DEVELOPMENT SHALL CONFORM TO THE NATURAL CONTOURS OF THE LAND AND NATURAL AND PREEXISTING MANMADE DRAINAGE WAYS SHALL REMAIN UNDISTURBED. O� 6. THIS DEVELOPMENT MUST BE PROVIDED WITH A DRAINAGE SYSTEM THAT IS ADEQUATE TO PREVENT THE UNDUE RETENTION OF SURFACE WATER ON THE DEVELOPMENT SITE. 1 7 7. NO SURFACE WATER MAY BE CHANNELED OR DIRECTED INTO A SANITARY SEWER.* 8. WHENEVER PRACTICABLE, THE DRAINAGE SYSTEM OF THIS DEVELOPMENT SHALL COORDINATE WITH AND CONNECT TO THE DRAINAGE SYSTEMS OR DRAINAGE WAYS ON SURROUNDING PROPERTIES OR STREETS. 9. CONSTRUCTION SPECIFICATIONS FOR DRAINAGE SWALES, CURBS AND GUTTERS, AND STORM DRAINS ARE CONTAINED IN APPENDIX C. 10. THIS DEVELOPMENT SHALL BE CONSTRUCTED AND MAINTAINED SO THAT ADJACENT PROPERTIES ARE NOT UNREASONABLY BURDENED WITH SURFACE WATERS AS A RESULT OF SUCH DEVELOPMENTS* 11. NO DEVELOPMENT MAY BE CONSTRUCTED OR MAINTAINED SO THAT SUCH DEVELOPMENT UNREASONABLY IMPEDES THE NATURAL FLOW OF WATER FROM HIGHER ADJACENT PROPERTIES ACROSS SUCH DEVELOPMENT, THEREBY UNREASONABLY CAUSING 59�� SUBSTANTIAL DAMAGE TO SUCH HIGHER ADJACENT PROPERTIES* 12. NO DEVELOPMENT MAY BE CONSTRUCTED OR MAINTAINED SO THAT SURFACE WATERS FROM SUCH DEVELOPMENT ARE UNREASONABLY COLLECTED AND CHANNELED ONTO LOWER ADJACENT PROPERTIES AT SUCH LOCATIONS OR AT SITE SUCH VOLUMES AS TO CAUSE SUBSTANTIAL DAMAGE TO SUCH LOWER ADJACENT PROPERTIES. 13. STORMWATER CONTROL FACILITIES SHALL BE MAINTAINED BY THE DEVELOPER. 14. ALL SIGNS REQUIRE SIGN PERMIT APPROVAL PRIOR TO INSTALLATION 15. ANY VARIATION TO THE APPROVED PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE TOWN OF SILER CITY DIRECTOR OF PLANNING AND COMMUNITY DEVELOPMENT FOR EVALUATION AND REVISED PLAN SUBMITTED FOR REVIEW AND APPROVAL. MEMORIAL DR 16. VEHICLE ACCOMMODATION AREAS OF ALL DEVELOPMENTS SHALL BE DESIGNED SO THAT SANITATION, EMERGENCY, AND OTHER PUBLIC SERVICE VEHICLES CAN SERVE SUCH DEVELOPMENTS WITHOUT THE NECESSITY OF BACKING UNREASONABLE DISTANCES OR MAKING OTHER DANGEROUS OR HAZARDOUS TURNING MOVEMENTS. US 64 / 11TH ST 17. EVERY VEHICLE ACCOMMODATION AREA SHALL BE DESIGNED SO THAT VEHICLES CANNOT EXTEND BEYOND THE PERIMETER OF SUCH AREA ONTO ADJACENT PROPERTIES OR PUBLIC RIGHTS -OF -WAY. SUCH AREAS SHALL ALSO BE DESIGNED SO THAT VEHICLES DO NOT EXTEND OVER SIDEWALKS OR TEND TO BUMP AGAINST OR DAMAGE ANY WALL, VEGETATION, OR OTHER OBSTRUCTION. _ 18, CIRCULATION AREAS SHALL BE DESIGNED SO THAT VEHICLES CAN PROCEED SAFELY WITHOUT POSING A DANGER TO PEDESTRIANS OR OTHER VEHICLES AND WITHOUT INTERFERING WITH PARKING AREAS. �Z = pn SILER CITY 19. VEHICLE ACCOMMODATION AREA SURFACES SHALL BE KEPT IN GOOD CONDITION (FREE FROM POTHOLES, EROSION, DUST, ETC.). rLn 20. NO OBSTRUCTIONS ARE ALLOWED WITHIN THE 10'X70' SIGHT DISTANCE TRIANGLES LOCATED AT DRIVEWAY EXITS <m ➢ m 21. VEGETATIVE BUFFERS ARE TO BE LEFT IN THEIR NATURAL STATE AND UNDISTURBED. rrn 22. PRIOR TO ANY FINAL PLANNING APPROVAL: I. SUBMIT ACTUAL AS -BUILT PLAN FOR ALL STORMWATER MANAGEMENT FACILITIES OR PRACTICES AFTER FINAL CONSTRUCTION COMPLETE* SITE NOTES: VICINITY M A P \ II. EXECUTE AND RECORD WITH THE REGISTER OF DEEDS A STORMWATER MANAGEMENT FACILITY OPERATION AND MAINTENANCE AGREEMENT PER§249.* \ III. SUBMIT WRITTEN FINAL INSPECTION APPROVAL FOR DRIVEWAY AND ENCROACHMENTS FROM NCDOT* NOT TO SCALE IV. WHENEVER A DEVELOPER INSTALLS ANY PUBLIC UTILITY LINE, THE DEVELOPER SHALL AFTER INSTALLATION IS COMPLETE, AND BEFORE ACCEPTANCE OF ANY WATER OR SEWER LINE, FURNISH THE TOWN WITH A COPY OF AN AS -BUILT DRAWING THAT SHOWS 1. PROPERTY INFORMATION THE EXACT LOCATION OF SUCH UTILITY LINES. V. SUBMIT WRITTEN FINAL INSPECTION APPROVAL FOR PUBLIC WATER AND SEWER UTILITY INSTALLATION FROM TOWN PUBLIC WORKS & UTILITIES DIRECTOR* OWNERS: TRUSTEES OF COMMUNITY BAPTIST CHURCH VI. SUBMIT VOLUNTARY ANNEXATION PETITION PER UTILITY EXTENSION POLICY PIN NUMBERS: 8752-02-56-2047 23. OBTAIN FINAL ZONING INSPECTION APPROVAL PRIOR TO USE/OCCUPANCY PARCEL ID: 0062776 EXISTING ZONING: A-R 24. ALL TREE AND SHRUB INSTALLATION SHALL BE IN COMPLIANCE WITH APPENDIX E OF THE UDO. SITE ADDRESS: 2575 HAMP STONE RD. SILER CITY, NC 27344 25. PARKING SPACES IN AREAS SURFACED IN ACCORDANCE WITH CONCRETE/ASPHALT SHALL BE OWNER ADDRESSES: 2575 HAMP STONE RD. SILER CITY, NC 27344 APPROPRIATELY DEMARCATED WITH PAINTED LINES OR OTHER MARKINGS. TOTAL SITE AREA: 29.66 ACRES. 26. ALL SIGNS SHALL BE IN COMPLIANCE WITH ARTICLE 18 OF THE UDO 27. NC EROSION LAWS ARE ADMINISTERED AND ENFORCED BY NCDEQ* 2. THE PROJECT IS LOCATED WITHIN THE TOWN OF SILER CITY LIMITS. 28. APPLICABLE BUILDING, ELECTRICAL, PLUMBING, AND HVAC CODES ARE ADMINISTERED, PERMITTED, AND ENFORCED BY THE CHATHAM COUNTY CENTRAL PERMITS AND INSPECTIONS DEPARTMENT* 29. APPLICABLE FIRE CODES ARE ADMINISTERED, PERMITTED, AND ENFORCED BY THE CHATHAM COUNTY FIRE MARSHALL* 30. STREAM DISTURBANCE APPROVAL IS REQUIRED FROM NCDEQ AND USACOE* PARCEL BOUNDARIES, TOPOGRAPHIC DATA, EASEMENTS, EXISTING WATER METER AND SANITARY SEWER ARE SHOWN PER FIELD SURVEY PERFORMED BY SURVEY CAROLINA 31. CONTACT COUNTY WELL AND SEPTIC, REQUIRES A SEPTIC SYSTEM ABANDONMENT PERMIT FOR THE AFFECTED SYSTEM AND SETBACK COMPLIANCE THROUGH ENVIRONMENTAL HEALTH. PLLC. DATED 05-19-2022. 32. IF THERE IS NO CONNECTION TO CITY SEWER, THEN THE PROJECT MAY REQUIRE A SEPTIC EXPANSION \ \ \ 3. PROPOSED USE: RELIGIOUS ASSEMBLY \ \ 4. PROPOSED NUMBER OF SEATS IN NEW SANTUARY: 416 5. SETBACKS: s \ o ROAD RIGHT OF WAY= 40 FT PROPERTY LINES = 20 FT \�2' \ _ 6. DISTURBED AREA: 2.87 AC. 0 \ 7. PROPOSED IMPERVIOUS AREA: 56,573 SF. (1.30 AC.) \ \ 8. NET BUA: 5.08% o \ \ 9. HANDICAP SPACES SHALL BE INSTALLED PER ADA REQUIREMENTS. 10' ® \\ 0 10. MAXIMUM SEPARATION BETWEEN SANITARY SEWER CLEANOUTS SHALL BE 50'. \ \ 11. OBTAIN ALL APPLICABLE PERMIT APPROVALS PRIOR TO ANY CONSTRUCTION. 8 \ \ \ 12. CONFIRM UTILITY TIE INS WITH ARCHITECTURAL DESIGN PRIOR TO CONSTRUCTION. SSA \ \ WETLAND NOTE: 13. WATER AND SEWER UTILITY TIE IN LOCATIONS ARE SHOWN ON THIS PLAN FOR /SS \ _ ♦ REFERENCE ONLY. 0 ._ S / 1 24.0 S 10 j / 12.5' .' 1L SS / 24.� / 12.5' 5.0 12.5 r20.0 VAN 24.0 f • Y:r f'''Nt VAN (TYP.) 91 PROPOSED BUILDING FFE 636.50, PROPOSED CONC. PAD 22.9' 19. TYP. 9.0 TYP. 7.0 (TYP.) PROPOSED LANDSCAPE AREAS 22.5' 24.0 \p 23.7' 22.9' 19' (TYP.) 24.0 1 9' TYP. PROPOSED FDC CONNECTION PROPOSED ASPHALT PARKING 22' 1\ THERE ARE NO WETLANDS LOCATED ON SITE PER FIELD EVALUATION PERFORMED BY \SUMMEY ENGINEERING AND LETTER SIGNED BY H. MACK SUMMEY JR. PE, DATED JUKE 14TH, 2022. EXISTING 8" DIP 24.0 1♦• 15'X150' SIGHT TRIANGLE \ EXTEND 15" RCP 16' PROPOSED 24' DRIVEWAY \ EXTEND 15" RCP 4' 19' / (TYP.) 90' \ ♦♦ \ ♦1 PROPOSED DOMESTIC WATER SERVICE \ �h'1_11��T►Yf� CONNECT PROPOSED 6" PVC WATER LINE TO EXISTING VALVE ENCASEMENT 4' TO EACH SIDE OF PAVEMENT. MIN OF 4FT OF COVER OVER ENCASEMENT PIPE EXISTING ROADWAY PAVEMENT PROPOSED FIRE HYDRANT AND GATE VALVE SEE ENLARGEMENT (THIS SHEET) 15'X150' SIGHT TRIANGLE \ EXISTING WATER MAIN �10' SET BACK BACKI - W W W EXISTING 8"X6" TEE EXISTING 6" VALVE BORE AND JACK ENCASEMENT UNDER ROADWAY 16" STEEL ENCASEMENT OR NCDOT APPROVED ALTERNATE PROPOSED 6"DIP 3 WATER LINE PROPOSED 6" CROSS PROPOSED 6" ELBOW PROPOSED 6" TO 2" REDUCER R/W LINE EEEEk\ PROPOSED 6" GATE VALVE PROPOSED 2" METER PROPOSED 6" - - - - _ - PROPOSED 2" BACKFLOW RPZ PREVENTOR PROPOSED 6" PVC FIRE LINE PROPOSED 2" PVC DOMESTIC LINE DRAWING LEGEND - - PROPERTY LINE ADJOINING PROPERTY LINE -ou ou ou OVERHEAD UTILITY OO EXISTING UTILITY POLE ® EXISTING SANITARY SEWER MANHOLE SS SS SS EXISTING SANITARY SEWER LINE SETBACK LINES EXISTING FIRE HYDRANT • PROPOSED SANITARY SEWER MANHOLE W W W EXISTING WATER LINE .................................. LIMITS OF CONSTRUCTION PROPOSED TREELINE EXISTING TREELINE GRAPHIC SCALE 30 0 15 30 60 90 IN FEET ) I 0 1 inch = 30 ft. -� oCA OWNER: 2 COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN N C , Q2Q� 9 l i • ' AL ' 6 26447 FN G I N C� S �J � � o U j o u 12 Z Il) m N N N N a: C13 N D Lu Q::� Fes- W w Lu ::� w O LnWO:�:zO i� LQ u C) 0 u au (, �_ U 0 �'_ Z p w 0 Lu Z d W a ud J W CL Z W U a CA- Z� w w a CL N N N N N N N N N N N N a� 00 '0 N o" a o00000 Z V Z J O V °� V F- w Z - z 1� W Z) Ln O ZE = Q N U Z >- F- V W O V N U 1-f-\ O 0 s m in a� in � 3 o Y u U O Z 0 Sheet No. I I i 000 000, i ,&* '" ftft .— 1-1 — — — -- '--1 I *EXISTING \\ ♦ \ / / / �� / XISTING \ HURCH O FF 634.5 (Est. cc"--� \ P CC, N N / / N / N �\ CC, 0 I •1• l \ , _ \ •• \ : O \ \ N\1 000 00 D ••�••• / / / / 5 \ ` \ \ CC SSA 24•Q PROPERTY 636 / ♦♦\� \ \�� \ \ \ \\\� 5'0 (� ♦♦ ♦♦♦� \ \o \ � EXTEND 15" RCP 16' 24.0 6 \ \ o� \ (TYP.) `ij \ 0 ou PROPOSED ♦"� \ou BUILDING \ �' EXTEND 15" RCP 4' FFE 636.5019. 9.0 TYP. TYP. \ \ \ 7.0 (TYP.) 24.04-w 0 N ♦♦ \ \ Io N \ \N \ \ 1 w 24.0 \-j i\ 110 Zi \ \ ` \ 2 FT DEEP POOL PRIOR TO SPREAD IR-01 \ \ \ \ ♦ O O O O O O O O O O O O \\ \ \ \ \ \ 433 V-.t xF. \ \ • 6'� \ ♦pill- / \ LEGEND PROPERTY LINE ADJOINING PROPERTY LINE OVERHEAD UTILITY EXISTING UTILITY POLE EXISTING SANITARY SEWER MANHOLE EXISTING SANITARY SEWER LINE SETBACK LINES EXISTING FIRE HYDRANT PROPOSED SANITARY SEWER MANHOLE EXISTING WATER LINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LIMITS OF CONSTRUCTION PROPOSED TREELINE EXISTING TREELINE GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. 0 �z I Do -Q� p 00 OWNER: 90 COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN ..gym n.••b .�' o� F E s io L � - 6 26447 - loo lo* FNG I N CA- S UMM �J 4 o y, ^ z . o W v E � m N N N N N D �z Q� Fes- W W Lu :�E W O d� 7 U �n uj ZdlUwow U W Z d W Di L. W C Z W Cl-U CA- Z ct� ul LLLJ a CL N N N N N N N N N N N N ai O O O O O O d Z ¢ m U W u- V oC z J O V °r- F- Z 0 0 Z w � CL CL O Z ~ c) O _ M\ � z ca v qo =¢ Ln ,DC^ v N U V W O V 0 s O a� � 3 ao Y u O Z Sheet No. i \ O O O O O O O O O C \61 _ 63-3 — 06 — ou 20 �Z CO AWING DRAWING LEGEND PROPERTY LINE ADJOINING PROPERTY LINE OVERHEAD UTILITY EXISTING UTILITY POLE EXISTING SANITARY SEWER MANHOLE EXISTING SANITARY SEWER LINE SETBACK LINES EXISTING FIRE HYDRANT PROPOSED SANITARY SEWER MANHOLE EXISTING WATER LINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LIMITS OF CONSTRUCTION PROPOSED TREELINE EXISTING TREELINE GRAPHIC SCALE 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. OWNER: 80 COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN /0 L 6 26447 4"2q"� ; K S UMM; .�`. .W,1111 '••.lolls ISO. Z Ei c� vJ NNNNNo m Z lu Q : Fes- W O w Z :]l W Lu ca o L O Z O Z ;Q Q �O U o?S U W oC U p Z Imo- W W C Z0'� ck�p Ln O CC w U cx: ON wj a. Z wLu Z °u Lu w a a rV N N N N rV N N N N N N ++ N rV 000000 d Z QooUOww V Z T J O y g Z no-noLu O C Z JLn N V V oC W N O V O z O N s � m gS ai +� � 3 v � v a, O Z cn o U Sheet No. PAVING NOTES: 1. ALL AGGREGATE BASE (ROADWAY, CURB, SIDEWALK) SHOULD BE 95% COMPACTED UNLESS DIRECTED OTHERWISE BY A GEOTECHNICAL ENGINEER. 2. CONTRACTOR TO VERIFY WITH OWNER THE EXTENTS OF RE —PAVING OR PAVEMENT REMOVAL AND REPLACEMENT. •i' _V, lkwA OVA MA HEAVY DUTY ASPHALT PAVEMENT SECTION NOT TO SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. c� mz I �D zu �� OWNER: COMMUNITY BAPTIST CHURCH 2575 HAMP STONE ROAD SILER CITY, NC 27344 CONTACT: PASTOR MARK AGAN ROl S/p ,d-S L y� 26447 ; K S `.J i. 4. r j aj r .0 c� vJ m NNNNNo Lu Q Fes- W Lu ca � LuOv Z O .o Q Z � �O Q U o?S U W oC U Z LOUC QQ) p W °� d V C O N O � w U � aNuja.zuj z Lu Lu Lu a W a rV N N N N rV N N N N N N O 00 O 0' N CV Q O O O O O O d Z Q m V O W u— V Z T J C) y I— Qo z Lu C z Q_ tlDQ Nc) z_ cp �_ N V Z �- V oC W O V O s O z N � aS ai � 3 � v O Z o o Sheet No. 25' 100' MIN. OR 4X CIRCUMFERENCE OF LARGEST TIRE (WHICHEVER IS GREATER) 4" MIN. EXISTING 4" MIN. PAVEMENT EXISTING GROUND EXISTING GROUND 2"-3" CLEAN STONE SIDE ELEVATION 100' MIN. OR 4X CIRCUMFERENCE OF LARGEST TIRE (WHICHEVER IS GREATER)_ 25' MIN. SILT FENCE, F OR CONSTRUCTION FENCE RETURNS EACH SIDE i PLAN VIEW 10' MIN. OR 25' RADIUS EXISTING PAVEMENT 10' MIN. OR 25' RADIUS CONSTRUCTION SPECIFICATIONS 1. STONE - USE COARSE AGGREGATE (2-3 INCH STONE) 2. LENGTH - AS EFFECTIVE, BUT NOT LESS THAN 100 FEET 3. THICKNESS - NOT LESS THAN EIGHT(8) INCHES 4. WIDTH - NOT LESS THAN FULL WIDTH OF ALL POINTS OF INGRESS OR EGRESS 5. WASHING - WHEN NECESSARY, WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. ALL SEDIMENT SHALL BE PREVENTED FROM ENTERING ANY STORM DRAIN, DITCH, OR WATERCOURSE. THROUGH USE OF SAND BAGS, GRAVEL, BOARDS OR OTHER APPROVED METHODS. 6. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. TEMPORARY CONSTRUCTION ENTRANCE NTS ni iTi rT ruin NOT INCLUDED WITH SKIMMER NOTE: INLET SCREEN SUPPLIED BY USER SCH 40 PIPE VARIES ON LARGER SKIMMERS SEE CALCULATIONS FOR SKIMMER SIZE SKIMMERS TO BE FAIRCLOTH SKIMMERS OR APPROVED EQUAL. SKIMMER DETAIL NTS WIRE OR ZIP TIES MIN. STRENGTH OF 50 PSI METAL FENCE POSTS 1.25 LB/LF MIN REINFORCING WIRE FENCE MINIMUM 14 GAUGE WIRE MAX. MESH SPACING OF 6" SILT —FENCE OVER HOG WIRE SILT FENCE ■ 1.0 FT. ■ MIN. FRONT VIEW VARIES (SEE PLAN) 4' MAX METAL FENCE POSTS CLASS B 1.25 LB/LF MIN RIP RAP O��,,��SILT )900000onoOOoOnoo no onno F FENCE SILT FENCE ALL STONE TO J L NCDOT #5 OR BE PLACED AT #57 WASHED A 2:1 SLOPE WIRE OR ZIP TIES STONE MIN. STRENGTH OF 50 PSI TOP VIEW MAINTENANCE REQUIREMENTS: - INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. - SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. - REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. - REMOVE ALL FENCING MATERIAL AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. NOTE: - REFER TO SILT FENCE DETAIL FOR MORE INFORMATION. SILT FENCE STONE OUTLET N.T.S. PLAN VIEW STEEL POST STAKE TO 4' O.C. TYP.----2 / SUPPORT WIRE, TYP. SUPPORT ROPE OR WIRE TO PREVENT SAGGING ��VAVAI &VAVAVA DAVAVA WVAV�� kVAVAVA VAVAVAI i&VAVA�� kVAVAVA WVAVAT, ANAM11' IA ,.......................... �,4 1,111 � &....VA LV....A W....R ►.....A .►..._.AI_ &_.A..VA LT....AI k....� D..._.A ►�' STEEL POST MIN. 24" IN_,` COIR MESH OR SIMILAR, GROUND BELOW BOTTOM STAPLED OR TRENCHED OF SED. TRAP SECTION ' X' INTO BOTTOM OR SIDE, TYP. BAFFLES MADE OF 700 G/M COIR EROSION BLANKET SIMILAR TO AND INSTALLED AS SEDIMENT FENCE. TYP OF 3 EA. BASIN, (2 IF BASIN IS 20' OR LESS IN LENGTH.) SKIMMER WITH IV,/ RETRIEVAL ROPE CROSS SECTION NOTE: SIZE SHOWN IS WATER VOL. W/RECOMMENDED SURFACE AREA. NOTE: ALL SEDIMENT TRAPS SHALL BE CLEANED OUT AFTER EACH SIGNIFICANT STORM. REPLACE STONE AND FILTER STONE AS MAY BE REQUIRED TO REFURBISH EACH SEDIMENT TRAP. TEMPORARY SEDIMENT TRAP w/ SKIMMER N.T.S. GENERAL NOTES/MAINTENANCE REQUIREMENTS 1. AREA UNDER EMBANKMENT TO BE CLEANED, GRUBBED AND STRIPPED OF ANY VEGETAION AND ROOT MAT. 2. FILL MATERIAL FOR THE EMBANKMENT SHALL BE FREE OF ROOTS OR OTHER WOOD/VEGETATION AS WELL AS OVER -SIZED STONES, ROCKS, ORGANIC MATERIAL OR OTHER OBJECTIONABLE MATERIAL. THE EMBANKMENT SHALL BE COMPACTED IN NOT GREATER THAN 9" LIFTS BY TRAVERSING WITH EQUIPMENT. 3. SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO IT ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. THIS DEPTH SHALL BE MARKED IN THE FIELD. 4. REMOVED SEDIMENT SHALL BE PLACED IN A DESIGNATED DISPOSAL AREA AND PROTECTED AGAINST EROSION. 5. THE WEIR MUST BE CONSTRUCTED LEVEL AND TO GRADE TO ASSURE DESIGN 6. STONES SHALL BE MACHINE PLACED AND SHOULD BE HARD, ANGULAR AND WEATHER RESISTANT. 7. EMERGENCY SPILLWAY SHALL BE DIRECTED TO NATURAL, STABLE AREAS 8. ALL CUT AND FILL SLOPES SHALL BE 2:1 OR FLATTER. 9. ALL DISTURBED AREAS SHALL BE STABILIZED IMMEDIATELY UPON COMPLETION OF CONSTRUCTION OF THE BASIN. 10. TRAP SHALL BE INSPECTED REGULARLY AND AFTER EACH RAINFALL WITH REPAIRS MADE AS NECESSARY. #67 FILTER STONE RIP —RAP PLACED AROUND PIPE INLET CLASS "A" 12"MIN RIP RAP FILTER STONE SECTION PLAN RIP —RAP INLET PROTECTION STRUCTURE N.T.S. PIPE OUTLET TO FLAT, NON -DEFINED CHANNEL PIPE OUTLET TO WELL-DEFINED CHANNEL I III III III II��I ai•b.•I.♦ ?.�.�.! I II II 1= = II - .•.•. II II .II II=11=. II II II:L u u •II II �II II. II' I -II II a iu II If II �' II II � II Ir=11t II II 11.,:11=11=II=11= II II II q=� II. I�. �I II _ I1-11v N.T.S. WITH LINER. NO GRAVEL APPROACH ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER 10'-0" MIN. A 0 CD C D 0 0 SANDBAGS (TYP.) OR STAPLES Z 0 O/_ 10 MIL 1:1 PLASTIC SANDBAGS (TYP.) q 0 SIDE SLOPE LINING OR STAPLES o (TYP.) O 0 M 0 0 Cp 0 0 = ,,.,,.,, oZXQ A CM0 l CLEARLY MARKED SIGNAGE SECTION A -A CONCRETE NOTING DEVICE (18"X24" MIN.) WASHOUT NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. PLAN 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUT DETAIL NTS NTS METAL FENCE POSTS 1.25 LB/LF MIN REINFORCING WIRE FENCE MINIMUM 14 GAUGE WIRE MAX. MESH SPACING OF 6" SILT FENCE FABRIC-----------,j ATSM 6461 OR EQUIV. WIRE OR ZIP TIES 18"-24" MIN. STRENGTH OF 2. 5' MIN 50 PSI q FLOW -coj I H " BACKF LL TRENCH �-- -I 24" MIN AND COMPACT THROUGHLY SECTION CROSS 8' MAX W WIRE FENCE 6' MAX W/O WIRE FENCE WIRE FENCE `SILT FENCE FABRIC i r ------------------- � r KEY IN 8" DOWN AND 4" FORWARD WIRE OR ZIP TIES EXISTING GRADE MAINTENANCE REQUIREMENTS: INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIAL AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. TEMPORARY SILT FENCE NTS 5-0 MIN ' 7�' Yam' lam' l "�-.♦'�.1'}������ ♦' �,1'�-��-��.ti� .-. �' Yam' Yam' +� � ' 414 i .��.- NORTH AMERICAN GREEN S150 OR EQUAL FOR TEMPORARY LINING CLEAN WATER DITCH NTS PEPMANE-N T SEEDING DEFINI TION Seeding disturbed areas with perennial grasses and (or) legumes to provide a permanent vegetative cover to lessen runoff and soil erosion. To lessen soil erosion and permanently stabilize disturbed areas created by grading of construction sites. CONDITIONS WHERE PRACTICE APPLIES All bare soil areas on construction sites which are not covered by structures or other erosion control devices. PREPARA TION Prepare seedbed by ripping, chiseling, harrowing or plowing to depth of six inches so as to produce a loose, friable surface. Remove all stones, boulders, stumps or debris from the surface which would prohibit germination or plant growth. Spread topsoil in a layer J" — 6" depth. Incorporate into the soil 800 to 1,000 pounds of 10-10-10 fertilizer plus 500 pounds of twenty percent (209) superphosphate per acre and two tons of dolomitic lime per acre unless soil tests indicate that a lower rate of lime can be used. Mulch after seeding with 1.5 tons of grain straw per acre and either crimp straw into soil or tack with liquid asphalt at 400 gallons per acre or emulsified asphalt at J00 gallons per acre. PLANTS & MIXTURE PLANTING RA TE/ACRE PLANTING DATES Tall Fescue 100-150 lbs. Aq. 15 — Oct. 15 (Low Main ten an ce) Feb. 15 — May 1 Tall fescue 200-250 lbs. Aug. 15 — Oct. 15 Waterways and Feb. 15 —May 1 Lawns (High Maint.) Blend of two turf— 200-250 lbs. Aug. 15 — Oct. 15 type tall Fescues Feb. 15 — May I (909) and two or more improved Ken tucky bluegrass varieties (10q) (high maintenance) Tall Fescue 100 lbs. Feb. 15 — May I and and Aug. 15 — Oct. 15 Kobe or Korean 20-25 lbs. Lespedeza Tall Fescue 50 lbs./acre No v. 1 — Feb. 1 (Unscarified) Tall Fescue and 60 lbs. July and August German Mille t or and Sudan grass 2 30 lbs. Tall Fescue 70 lbs. No v. 1 —Jan. JO and and Ryegrain 2 25 lbs. Common Bermudagrass 8 lbs. (hulled) April 15 — June JO 15-20 lbs. (unhulled) Feb. 1 — March JO 1 For spring seedings, use Scarified Lespedeza seed. For late fall and winter seedings, use unscarified seed. 2 Annuals such as Millet, Sudangrass and Rye grain must be kept at 10-12" maximum h eigh t. PERMANENT GROUNDCO VER Permanent groundcover is to be provided for all disturbed areas within 15 working days or 90 calender days (whichever is shorter) following completion of construction or de velopm en t. TEMPORARY SEEDING SPECIFICATIONS PIEDMONT REGION Application Rates (lb/ac) Recommended Species 10-10-10 Agriculural Straw Seeding Dates Seed Fertilizer Limestone Jan. 1 — May 1 Winter Wheat Annual Lespedeza 120 50 750 2,000 4,000 (Kobe) May 1 — Aug 15 German Millet 40 750 2,000 4,000 Aug 15 — Dec 30 Ryegrain 120 1,000 2,000 4,000 COMPACTED SOIL OR STONE I 2' MIN. 3:1 max(stone) FLOC .�' '•�:' =� ',-"�=�.'-;�:;;;:..; 18" MIN. 6' TYP I 9' TYP(stone) CONSTRUCTION SPECIFICATIONS REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONAL MATERIAL. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE INSPECT TEMPORARY DIVERSION ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL END APPROPRIATELY STABILIZE IT. TEMPORARY DIVERSION DITCH NTS Know what's below. Call before you dig. 0 [ S /10 QQ 9 G AL • • = 26447 •*ice FN G I N SU _iik � O ^I U oaf o cq r k N O lu � •r� � c 1 m Z UU�JUU N N N N N m Z LU W F�— F~�— O� W Z W U LU O Cn L O z O oZ�Cki .6 Q Uj,oI �Q-� ~ LU Z O)W LU I—UV�p v, O � W ULU oC �� a Z"'a CC LU LU i N N N N N N N N N N N N aj a0 �O ::4 Q` 0 000000 Zo QmUa W W V z X J k-041) - U 0 W O oc 0 J 0 Z 2: oC o j z M— a U 0 W = Q Q `V U v) Z c F- U W oc w O V O z O N s \Sl� m a� cn 0 V Sheet No.