Loading...
HomeMy WebLinkAboutSW8960711_HISTORICAL FILE_19960910STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 °I� 11 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS © HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE OjQ) 0c1 YYYYMMDD State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality k James B. Hunt, Jr., Governor C A , p Jonathan B. Howes, Secretary C , V �i A. Preston Howard, Jr., P.E., Director September 10, 1996 Mr. Joe H. Christian, President 1612 Front Street L.L.C. Post Office Box 659 Beaufort, North Carolina 28516 Subject: Permit No. SW8 960711 1612 Front Street High Density Subdivision Stormwater Project Carteret County Dear Mr. Christian: The Wilmington Regional Office received the Stormwater Management Permit Application for 1612 Front Street on July 22, 1996, with final information on August 23, 1996. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 960711, dated September 10, 1996, for the construction of 1612 Front Street. This permit shall be effective from the date of issuance until September 10, 2006, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an ajudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3906. Sincerely, ?imBushardt, P.E. Acting Regional Water Quality Supervisor JBB/arl: S:\WQS\STORMWAT\PERMIT\960711.SEP cc: Ron Cullipher, P.E. Garry Yeomans, Carteret County Inspections Linda Lewis Wilmington Regional Office Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer State Stormwater Management Systems Permit No. SWS 960711 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT ffiGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO 1612 Front Street L.L. C. 1612 Front Street Carteret County FOR THE construction, operation and maintenance of a Detention Pond in compliance with the provisions of 15A AXAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until September 10, 2006 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The subdivision is permitted for 11 lots, Lots 1-10 allowed 3,500 square feet; Lot 11 allowed 4,500 square feet of built -upon area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. K C State Stormwater Management Systems Permit No. SW8 960711 DIVISION OF WATER QUALITY PROJECT DATA SHEET Project Name: Permit Number: Location: Applicant: Mailing Address: Application Date: Water Body Receiving Stormwater Runoff: Classification of Water Body: If Class SA, chloride sampling results: 1612 Front Street 960711 Carteret County Mr. Joe H. Christian, President 1612 Front Street LLC Post Office Box 659 Beaufort, North Carolina 28516 July 22, 1996 Taylor's Creek "SC" N/A Pond Depth: 7 feet Permanent Pool Elevation: 5 MSL Total Impervious Surfaces Allowed: 70,050 square feet (Lots 1-10 @3,500; Lot 11 @4,500 plus roads and sidewalk) Offsite Area entering Pond: N/A square feet Green Area entering Pond: 44,736 square feet Required Surface Area: 2,814 square feet Provided Surface Area: Required Storage Volume: Provided Storage Volume: Temporary Storage Elevation: Controlling Orifice: 2,817 square feet 5,732 cubic feet 6,522 cubic feet 6.9 MSL V pipe M State Stormwater Management Systems Permit No. SW8 960711 4. No homeowner/lot owner/developer shall fill in, alter, or pipe any drainage feature (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 5. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built -upon area. Once the lot transfer is complete, the built -upon area may not be revised without approval from the permittee, and responsibility for meeting the built -upon area limit is transferred to the individual property owner. , 6. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. c. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. f. Filling in, altering, w piping of any vegetative conveyance shown on the approved plan. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 7. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads. b. During construction, erosion shall bekept to a minimum and any eroded areas of the system will be repaired immediately. 2. The permittee grants permission to DEHNR Staff to enter the property for the purposes of inspecting the project for compliance with the conditions of this permit. 4 N State Stormwater Management Systems Permit No. SW8 960711 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in it's entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Prior to the sale of any lot, deed restrictions must be recorded which limit the built -upon area per lot to the amount as shown on the Project Data Sheet, per Part I #2. The recorded statements must follow the form: a. "The maximum built -upon area for lots 1-10 is 3,500 square feet, and for Lot 11, 4,500 square feet, inclusive of that portion of the rigbt-of-way between the lot line and the edge of pavement, structures, pavement, walkways of brick, stone, or slate, but not including open wood decking. " b. "The covenants pertaining to stonnwater regulations may not be changed or deleted without concurrence of the State." 11 y,. c. "Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the State." d. "Lots within CAMA's Area of Environmental Concern may be subject to a reduction in their allowable built -upon area due to CAMA regulations." If the subdivision exceeds low density, one of the following additional statements are necessary to ensure that all runoff from built -upon areas of the lot is picked up by the pond. Additional statements include: e. "Roof drain gutters are required on all homes and must drain into the street." f. "Two-thirds of the lot must be graded toward the street." "Perimeter swales and ditches must pick up the runoff and direct it into the pond." 6. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 5 State Stormwater Management Systems Permit No. SW8 960711 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. 8. A copy of the recorded deed restrictions must be submitted to the Division within 30 days of the date of the recording. The recorded copy must be signed by the permittee, dated, stamped with the deed book number and page, and bear the stamp of the Register of Deeds. 9. A copy of the approved plans and specifications shall be maintainer) on file by the Permittee for a minimum of ten years from the date of the completion of construction. III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request form must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement storinwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 10th day of September, 1996. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION A. 1 ton Howard, Jr., P.E., Director DiZion of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 960711 E. State Stormwater Management Systems Permit No. SW8 960711 1612 Front Street Stormwater Permit No. SW8 960711 Carteret County Engineer's Certification I, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the• project, for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Noted deviations from approved plans and specification: Signature Registration Number Date 7 ry POND MAINTENANCE REQUIREMENTS Project Name: 1612 Front Street Project No. Responsible Party: 1612 front Street Associates, LLC Phone NO. (919) 728-5462 Address: P.O. Box 659, Beaufort, N.C. 28516 I. Monthly, or after every runoff producing rainfall event, whichever comes fast: A. Inspect the trash rack; remove accumulated debris, repair/replace if it is not functioning. B. Inspect and clear the orifice of any obstructions. If a pump is used as the drawdown mechanism, pump operation wiil be checked. A log of test runs of the pump will be kept. on site and made available to DEM personnel upon request. C. Inspect the pond side slopes and grassed inlet swales; remove trash, and repair eroded areas before the next rainfall event: D. If the pond is operated with a vegetated filter, the filter will be checked for sediment accumulation, trash accumulation, erosion and proper operation of the flow spreader mechanism. Repairs/cleaning will be done as necessary. H. Quarterly: A. Inspect the collection system (ie. catch basins, piping, grassed swales) for proper functioning. Accumulated trash will be cleared from basin grates, basin bottoms, -and piping will be checked for obstructions and cleared as required. B. Pond inlet pipes will be checked for undercutting, riprap or other energy dissipation structures will be replaced, and broken pipes will be repaired. III. Semi-annually: A. Accumulated sediment from the bottom of the outlet structure will be removed. B. The pond depth will be checked at various points. If depth is reduced to 75 % of original design depth or 3 feet whichever is greater, sediment will be removed to at least the original design depth. C. Grassed swales, including the vegetated filter if applicable, will be reseeded twice a year as necessary. IV DIVISION OF ENVIRO NORTH C NME.NTAL MANAGENIENT AROLINA STORNIWATER I - GENERAL MANAGEMENT PERMIT APPLICATION INFORMATION 1. Project Name 1612 2. Location, directions to project (include County, Address, State Road) Attach ma (NCSR 1312), Town of Beaufort CartP• 1612 Front Street eret Count 3. Owner's Name 1612 Front Street Associates 4.Owner's Mailin L.L.C. Phone (919) 728_5462 Mailing P.O, Box 659 5. App]ication date August 22 S NIC4 28516 —_P, , 1996 6. Nearest Receiving Fee enclosed $ 385.00 eceivingStream Taylor's Creek 7.Projectdescription Class SC Sin le family residential II• PERMIT EFORMATION I-Per7nitNo. (Ibbef,lkdinbyD..) SW8960711 2. Permit Type g New_ Renewal Low Densl o a Modification (existing 3. Project Type: Permit No.) Detention Infiltration Other:,Redevelop General 4. Other State/Federal Permits/Approv s equired (Ch,ckn __Dir Cert ppropriaie blankrJ LAMA Major Sedimentation/Erosioll Control g HI' BUILT UPON' AREA (Pleare see NCAC 2KIA75,1,M.1007jor applicablede,,Zy li ,)404 Permit Classification Allowable Impervious Area Total Project Area Proposed Impervious Area To Impervious Area STORNIWATER TREATAUNT Drams Bain SC 0.66 ac 22. 64 ac 1.6— ac 61Z Dr�ti Bain SC 0.03 ac 0.110ac 0 ac 0% (Describe haw the runaffWill be treated) Breakdown of Im ervious Area (Plea.,', indicate below tIle design imperNo,u area) Buildings 39,500 sf Streets 26,700 sf Parking/SW 3,850 sf Other Totals 70,500 sf = 1.61 ac ' V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VI. OWNER'S CERTIFICATION I, Joe H. Christian (Plcare print or type mmne clearly) certify that the information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000. I authorize the below named person or firm to submit stormwater plans on my behalf. Agent Signature and Title VH. AGENT AUTHORIZATION (Musrae coMprE7w) Date Person or firm name Stroud Engineering, P.A. Mailing Address Hestron Plaza One, Suite 102 City Morehead Citv State NC Zip 28557 Phone (919) 247=7�79 Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO//Central Files Office use only nECEIVE�� I AUG 2 31996 PROJ# M 11� ATTACHMENT A LOW DENSITY AND SUBDIVISION PROJECTS GENERAL SUBMITTAL REQUIREMENTS 1. A completed stormwater permit application. 2. Two sets of plans showing north arrow, scale, revision date, property/project boundaries, lot lines, proposed and existing contours,'drainage areas, mean high water line, wetlands, easements, the 30, minimum vegetated buffer between impervious areas and surface waters, proposed impervious areas, and road cross -sections. Calculations of the built -upon area, For subdivisions, please show the methodology for arriving at the per lot built -upon area. For non -subdivision projects, please break down the calculation into buildings, reads, parking; and other (include all impervious areas). 4. Low density projects with curb and gutter will require: a. Drainage area delineation and swale locations shown on the plans. b. Detail of the swale, showing minimum 5:1 side slope. C. Velocity calculations, indicating a non -erosive flow for the 10 yr storm. d. Inlet and outlet elevations. Maximum longitudinal slope is 5%. e. The type of vegetated cover specified on the plans. DEED RESTRICTION REQUIREMENTS The following statements must be included for all low density projects, and for 0 subdivisions: 4,500sf Lot 11, 3,500 sf Lots'_1'-10 No more than square feet of any lot, including that portion of the right-of-way between the edge of pavement and the front lot line, shall be covered by impervious structures, including asphalt,,gravel, concrete, brick, stone, slate or similar material, not including wood decking or the water surface of swimming Pools. This covenant is intended to ensure continued compliance with the stormwaterpermit issued by the State of North Carolina. The covenant may not be changed or deleted without the consent of the State. No one may fill in or pipe any roadside or lot -line Swale, except as necessary to provide a minimum driveway crossing. For curb and gutter projects, no one may pipe, fill in, or alter any lot line Swale used to meet North Carolina Stormwater Management Permit requirements. NOTE If lot sizdvary significantly, the owner/developer must provide an attachment listing each lot number, size, and the allowable built -upon area for each lot. DIVISION OF ENVIRONMENTAL MANAGEMENT NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION I. GENERAL INFORMATION 1. Project Name 1612 Front Street 2. Location, directions to project (include County, Address, State Road) Attach map. 1612 Front Street (SR 1312), Town of Beaufort, Carteret County 3. Owner's Name Mr. & Mrs. P. E. Davidson, Jr. Phone 4.Owner's Mailing Address 4407 Ortega Forest Drive City Jacksonville State Florida Zip 32210 5. Application date July 17, 1996 Fee enclosed $ 385.00 6. Nearest Receiving Stream Taylor's Creek Class 7.Projectdescription Single family residential subdivision. II. PERMIT INFORMATION 1. Permit No.troberuedin byDEM) 2.Permit Type X New Renewal Modification (existing Permit 3. Project Type: _Low Density x Detention Infiltration Other:_ Redevelop _General _Dir Cert 4. Other State/Federal Permits/Approvals Required (Check appropriate blanks) CAMA Major Sedimentation/Erosion Control X 404 Permit III. BUILT UPON AREA (Please see NCAC 2FL1005 thru .1007for applicable density limits) Classification i Allowable Impelus Area Total Project Area Drainage Drainage Basin Ill . Basin lit SC SC 0.66 ac 0.03 ac 2.64 ac 0.10 ac Proposed Impervious Area 1.61 ac 0 ac % Impervious Area 61% 0% IV. STORMWATER TREATMENT Peso ibe how the runoff will be treated) Wet detention. Breakdown of Impervious Area (Please indicate below the design impervious area) Buildings 39,500 sf Streets 26,700 sf Parking/SW 3,850 sf Totals 70,500 sf = 1.61 ac (Design impervious area.) ., V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VI. OWNER'S CERTIFICATION I Carolyn Davidson certify that the information included on this permit (Pleare print or type name clearly) application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 211.1000. I authorize the below Ramson or firm to submit stormwater plans on my behalf. n /11 Signature and Title VII. AGENT AUTHORIZATION (MUSTBE COWL=) Person or firm name Joe H. Christian. Mailing Address P.O. Box 659 Date City Beaufort State N.C. Zip 28516 Phone (919) 728-5462 Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO//Central Files STATE E C E l V E O JUL 2 21996 PROJ POND MAINTENANCE REQUIREMENTS PAGE 2 IV. General: A. Mowing of the side slopes will be accomplished according to the season. Maximum grass height will be 6". B. Cattails are encouraged along the pond perimeter, however they will be removed when they cover more than 1/2 the surface area of the pond. C. The orifice/pump is designed to draw down the pond in 2-5 days. If drawdown is not accomplished in that time, the system will be checked for clogging. The source of the clogging willbe found and eliminated. D. All components of the detention pond system will be kept in good working order. Repair or replacement components will meet the original design specifications as per the approved stormwater plan. V. Special Requirements: " I .Toe H. Christian hereby acknowledge that I am the financially responsi e party for maintenance of this detention pond. I will perform the maintenance as outlined above, a part of the Certification of Compliance with Stormwater Regulations received for this project. Signature: Date: June 26, 1996 I, Dion John Viventi a Notary Public for the StateOf North Carolina County of 9'Carteret , do hereby certify that Joe H. Christian personally appeared before me this 26th day of June , 19 96, and acknowledge the due execution of the foregoing instrument. Witness my hand and official seal, 4� My commission expires -� S" �8" �A onend a .tlN1O0 ; DA/arl: S:\WQS\STORMWAT\FORMS\O&M-POND.FOR NHOT, 0 STROUD ENGINEERING, P.A. HESTRON PLAZA ONE SUITE 102 MOREHEAD CITY, NORTH CAROLINA 28557 (919) 247-7479 Ms. Linda Lewis NCDEHNR Division of Water Quality 127 Cardinal Drive Extension Wilmington, N.C. 28405-3845 RE: 1612 Front Street Beaufort, Carteret Co. Dear ewis, August 22, 1996 ;I €l UI �it�i=il;1 +t �M�UT��D AUb 2 3 1996 With regards to your letter of request for additional information dated August 14, 1996, the following items have been addressed: 1) The owner of the above referenced property is presently 1612 Front Street Associates, L.L.C., therefore, I have prepared a revised application form to reflect the change in ownership and to show Stroud Engineering as_ authorized to submit stormwater plans on their behalf. 2) The grading plan has been revised to show three feet deep forebays for both inlets separated from the main pond as requested. 3) The detail sheet has been revised to show the location, width, 6:1 sideslopc and elevation of the vegetative shelf on the wet pond section detail as requested. I have also shown the forebay bottom elevation on this detail as well. Two copies of the revised plans and application have been enclosed for your approval. If there are any question or comments please let me know. DJV/kw FIIeA81I.ewls.txl 107 COMMERCE ST. SUITE B GREENVILLE, NC 27858 (919) 756-9352 Sincerely, Dion J. Viventi, E.I.T. HESTRON PLAZA ONE SUITE 102 MOREHEAD CITY, NC 28557 (919) 247-7479 AUG-22-9VV6_THU 15:43 BEAUFORT REALTY 9197281322 P.02 � ug li re I Prepared by C. R. Wheatly, I11, Attorney, Beaufort, NC 28516 NORTH CAROLINA PARCEL # 73a5'9 a I I CARTERET COUNTY WARRANTY DEED 8 ; THIS DEED, made this 31 day of (�1 199 G , 8 by and between P. E. DAVIDSON and wife, CAROLYN DAVIDSON, of Jacksonville, Florida, party of the first part and 1612 FRONT STREET ASSOCIATES, L.L.C., whose address is P. O. Box 659, M. Beaufort, North Carolina 28516, party of the second part; W I T N That party of the first part, for a valuable consideration paid by party of the second part, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto party of the second part, in fee simple, all that g certain lot or parcel of land situated in Beaufort Township, Carteret County, North Carolina and being more particularly O described as follows: BEGINNING AT A POINT located in the southern right-of- way of Lennoxville Road which point is located S 44-01- 30 E 272.47 feet from the centerline intersections of the Old B&W Railroad Track and Lennoxville Road; thence from said point of beginning so located and running with the southern right-of-way of Lennoxville Road S 50-34-00 E 197.90 feet to an iron pipe{ thence running S 06-44-30 W 532.19 feet to a point; thence running S 07-00-40 E 72.83 feet to a point; thence running S 16-42-40 W 176.14 feet to a point in the northern right-of-way of Front Street; thence with the northern right-of-way of Front Street S 66-36-00 E 13.75 feet to a point; thence running across Front Street to the high-water mark of Taylor's Creek S 06-44-30 W 97.41 feet; thence with the high-water mark of Taylor's Creek N 71-12-00 W 115.32 feet to a point; thence running N 03-47-25 E 446.06 feet to a point; thence running N 03-19-10 E 516.31 feet to _.; the point and place of beginning. Being all of that property as shown on that survey entitled 1612 Front 5,T 'Sheet by Stroud Engineering, P.A., which description is �'•T,sa incorporated herein by reference. The above -described ' tl� 6 property was acquired by the grantor by deed and =CHIVE AU 2 31996 D BOOi� --J�s Pam' E M PROJ H AUG-22 THU 15:44 BEAUFORT REALTY 9197281322 P.03 2 recorded in Book 492 at Page 351 and Hook 630 at Page 411, both of the Carteret County Registry. There is excepted from the warranties of the above property the portion of the above tract located within the bounds of the 60 foot right-of-way of Front Street. TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to party of the second part, in fee simple. And party of the first part covenants with party of the part, that they are seized of the premises in fee simple, the right to convey the same in fee simple, that title is and free and clear of all encumbrances, and that party the first part will warrant and defend the title against the claims of all persons whomsoever except for the exceptions fter stated. IN WITNESS WHEREOF, party of the first part has hereunto set his hand and seal, the a frL fir@t above written. r (SEAL) P. vE. DA I ON oi�¢&*� (SEAL) CAROLYN DKVIDSON NORiH-CAROLINA CARTERE`P COUNTY //�o-uti�y a�yF J7�.✓a/� I, 2-1111 irr t. ".'� C: ��lr� , Notary Public of the County and State aforesaid, certify that P. E. DAVIDSON and wife, CAROLYN DAVIDSON personally appeared before me this day and acknowledged the due execution of the foregoing document. ST WLViE$S my hand and notarial seal this the -3/ day of �� , 1996. Commission Expires: Notary Public $ EMEMMME L. CLAW t%y WQ9YYt9SGM/L'CYQSi? r fig: Nc2/, 199E 97nY071w NedY nc9e li�l9lh BOOK �� PAGE- _AUG-22-II6 THU 15:45 BEAUFORT REALTY 9197281322 P.04 3 CAROLINA RET COUNTY The foregoing certificate(s)kFS`k+� are v We cVLLWca. r111s insLrumenL wasr 9 me on and recorded in thi office n Book , k4L _ O day of 19 L i� , at o'clock H. m BOOK PAGE a State of North Carolina Department of Environment, Health, and Natural Wilmington Regional Office James B. Hunt, Jr. DIVISION OF WATER QUALITY Governor WATER QUALITY SECTION August 14, 1996 Mr. Ron Cullipher, P.E. Stroud Engineering Hestron Plaza I, Suite 102 Morehead City, North Carolina 28557 Resources Jonathan B. Howes Secretary Subject: ADDITIONAL INFORMATION Stormwater Project No. SW8 960711 1612 Front Street Carteret County Dear Mjc— ipher: The Wilmington Regional Office received a Stormwater Management Permit Application for 1612 Front Street on July 22, 1996. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please provide a signed agent authorization from Ms. Davidson which authorizes Mr. Christian to sign the permit application and the Operation and Maintenance Plan. The authorization space on the permit application is where the applicant authorizes the engineering firm to submit stormwater plans on his/her behalf. The Stroud Engineering firm name and address should go in this space. You may also have Ms. Davidson sign the permit application and 0 & M Plan. 2. Please add a forebay detail to the pipe inlet detail. Every inlet into the pond must have a forebay. The forebay is a shallow area (=2'-3' deep), separated from the main pond by a weir, that holds =20% of the pond storage volume. Since you have 2 inlets, each forebay would hold 10% of the volume. See enclosed detail. 3. Please add the location, width, 6:1 slope and elevations of the vegetated shelf to the wet pond section detail. The shelf is generally located nearer the permanent pool to provide regular inundation of the wetland plants in the shelf area. 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer Mr. Cullipher August 14, 1996 Stormwater Project No. SW8 960711 Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to September 14, 1996, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, 46 �; ' � d�- Ms. Linda Lewis Environmental Engineer DA/arl: S:\WQS\STORMWAT\ADDINFO\96071LAUG cc: Linda Lewis Central Files 2 STROUD ENGINEERING, P.A. Hestron Plaza One Suite 102 MOREHEAD CITY, NC 28557 (919) 247-7479 J U L 2 2 1996 TO /Z WE ARE SENDING YOU ($;Attached ❑ Under separate cover via _ ❑ Shop drawings ❑ Prints ❑ Copy of letter ❑ Change order ❑ Plans dC UCTIE 3 OCR 4EM"MOUCTM n ❑ Samples — rD Specifications V E M ®-_ NO MOM IX For approval ❑ For your use ❑ As requested ❑ Approved as submitted ❑ Resubmit copies for approval ❑ Approved as noted Cl Returned for corrections ❑ For review and comment ❑ ❑ FORBIDS DUE REMARKS ❑ Submit copies for distribution ❑ Return corrected prints 19 ■ PRINTS RETURNED AFTER LOAN MIN COPY If enclosures are not as noted, kindly notify us at once. I a 8EA1. �poy 188/9 ,y�4940 D. C11I gggnuu•� .40 File:47Marrati5.txt Narrative Erosion & Sedimentation Control Plan Stormwater Management Plan 1612 Front Street Beaufort, Carteret County, North Carolina July 17, 1996 Client: 1612 Front Street Associates, L.L.C. P.O. Box 659 Beaufort, North Carolina 28516 (919) 728-5462 Engineer: Stroud Engineering, P.A. Hestron .Plaza One, Suite 102 Morehead City, North Carolina 28557 (919) 247-7479 Ronald Cullipher, P.E. n E C E I V E y �IJnu{ JUL 2 219996 0 PROJ A W %I Y1,11 ANT9 40 r' 0 • A. Description of Project 1. Type of Development The 1612 Front Street project located on SR 1312 in Beaufort, Carteret County, North Carolina is a proposed single family residential subdivision. All planned construction work will take place within the 2.91 acre tract bounded to the north by SR 1309 to the south by Taylors Creek, the cast by N/F Robert M. Lewis Property and Laurel Lane and to the west by N/F C. R. Wheatly, III Property. 2. Earth Disturbing Activities a. Clearing and grubbing of right-of-way and construction areas. b. Cleanup and grading activities associated with street, parking, structural and drainage construction. C. Installation of underground utilities including subsurface storm drainage facilities. • d. Paving, building, parking, and landscaping construction activities. B. Stormwater Management, Erosion and Sedimentation Control Prior to development, untreated stormwater runoff drained from the site primarily via sheet flow and collected by existing ditches and subsurface drainage facilities which carried the water to Taylor's Creek. Development of the project shall address applicable stormwater management and erosion control concerns for all new impervious surfaces with the following measures: 1. Collection and wet detention designed to treat and discharge first inch of stormwater runoff volume on a 10 year storm frequency basis. 2. Protection of proposed facilities and downstream waters from effects of erosion during and after construction utilizing methods and facilities outlined in sequence described below. C. Time Sequence of Operations 1. Installation.of stone construction entrance. 2. Clear and grub right-of-way and constructions areas. 3. Installation of silt fencing.. • 4. Rough grade construction areas and subgrade street. File:47114artati5.at • 5. Install subsurface stormwater drainage facilities and underground utilities. 6. Install concrete curb and gutter.. 7. Place stone base course in street. 8. Seed construction areas outside of proposed street. 9. Pave streets. 10. Construct buildings, sidewalks, and concrete drives. 11. Final grading, landscaping, and seeding. 12. Check/maintenance of erosion control and stormwater management facilities. D. Coastal Stormwater Regulations" The North Carolina Division of Environmental Management implemented Coastal Stormwater Regulations in coastal counties in January 1988. These regulations are detailed in 15NCAC 21-1.1000 Stormwatcr Runoff Disposal. These rules were implemented to limit waste constituents and resulting pollutant loads on waters of the state. 1612 Front Street.is a residential subdivision development project involving stormwater treatment of new impervious surfaces proposed within the tract. The measures outlined above, combined with the maintenance plan described below, should contribute to the reduction of waste constituents and resultant pollutant loads on the downstream waters affected by this project. • E. Maintenance Plan Upon completion of construction any accumulated silt shall be removed from basins, drainage structures, and subsurface pipes. The owner shall implement a maintenance plan that incorporates, as a minimum, the following: 1. Inspect the drainage structures and outlet control devices monthly and remove any sediment or debris that has accumulated. 2. Maintain and mow grass on a regular schedule. Ensure that grass height is maintained below four inches. File:47NmatO.ty Technical Specifications • 1612 Front Street Beaufort, Carteret Co., North Carolina July 17, 1996 Is File:47/161M.lxt Client: 1612 Front Street Associates, L.L.C. P.O. Box 659 Beaufort, North Carolina 28516 (919) 728-5462 Engineer: Stroud Engineering, P.A. Hestron Plaza One, Suite 102 Morehead City, North Carolina 28557 (919) 247-7479 �9G ' �L D. my Ronald D. Cullipher, P.E. Date 0 U Division 1 Earthwork Pg. 3 Division 2 Asphalt Concrete Paving Pg. 5 Division 3 Curb & Gutter Pg. 8 Division 4 Seeding & Mulching Pg. 9 Division 5 Site Grading Pg. 12 Division 6 Storm Drainage & Erosion Control Pg. 15 Division 7 Water Distribution System Pg. 19 Division 8 Sewer System Pg. 2.6 File:47/1612fuxt Page 2 Division 1 Earthwork A. Scope of Work The work to be performed under this section consists of furnishing all tools, labor, materials, equipment, and other things necessary to complete all excavation and backfill for roadways, backfills, or embankments required for bringing all portions of the site to finish grades as shown on drawings, excavations, and backfill of trenches. B. Workmanship 1. Erosion and Sedimentation Control. Prior to beginning any earth -disturbing activity, the Contractor shall construct all silt fences, straw bale barriers, and/or other erosion and sedimentation control devices as shown on the plans or as directed by the Engineer. 2. Roadway Excavation Excavation shall be to line and grade as established by the Engineer. • The Contractor shall exercise caution to prevent excavation lower than established subgrade, but in the event this has been done, the low places shall either be backfilled with suitable material or replaced with compacted stone base, as directed by the Engineer. Excavated material, when suitable, shall be used as embankment wherever required and the Contractor shall so schedule his operations as to be able to move surplus excavation to areas which will require embankment. Surplus excavation shall be hauled, spread, and compacted in a predetermined area designated by the Engineer. 3. Embankments - Method of Construction File:47/1612fs.txt Embankments shall be formed of earth or other material having met the approval of the Engineer. After the site has been prepared, the entire surface shall be thoroughly rolled. Embankment shall be built up full width from the bottom in successive layers not exceeding six (6) inches in thickness, loose depth, with sides kept slightly higher than the center. Each layer shall be compacted to 95% of maximum density as determined by the standard proctor methods conducted in accordance with ASTM D 698. Street shall be proof - rolled with a loaded dump truck prior to paving. Compaction testing shall be provided if requested by the Town of Beaufort. Proof -rolling shall be observed by a Town of Beaufort representative. Page 3 During the process of construction, the Contractor must reasonable distribute all hauling and traffic over the surface of the embankment so that it • may become uniformly solidified. The Contractor will beheldfully responsible for the stability of all embankments and shall repair all damages to embankments which occur prior to final completion of the work covered by the Contract. 4. Undercutting Should faulty soil conditions be found while preparing the subgrade, the unsuitable material shall be removed as directed and the subgrade be brought to proper elevation by filling with suitable material excavated from other sites. 5. Disposal of Waste Excavation Excess material which is.not used for embankments shall be disposed of in a predetermined area designated by the Engineer. Waste material shall be spread in a manner that drainage will .be maintained at all times. 6. Field Density Tests Field density tests shall be made on each layer of fill as it is • constructed. A minimum of three tests shall be made on each layer of roadway fill under pavement for each 100 if of street. Tests shall be constructed in accordance with ASTM D 1556 Sand Cone method. the initial series of tests will be paid for by the Owner. If the specified compaction has not been attained, the Contractor shall farther compact the fill and furnish additional field density tests as determined to be necessary by the Engineer. The additional test shall be conducted at the Contractor's expense. C. Payment Payment shall be included in the contract price. File:47/1612fs.txt Page 4 Division 2 Asphalt Concrete Paving A. General 1. Scope of Work Fumish all tools, labor, material, and equipment as required to perform subgrading, fine grading and construct all paved areas. 2. Quality Assurance Testing Requirements When the subgrade has been prepared and prior to placing any base course material, notify the Engineer. The Engineer will check the subgrade for compliance with planned profile and cross-section. Density tests may be required at the descretion of the Engineer. The initial test will be paid for by the Owner. Any areas which fail to meet compaction requirements as set forth in Division 2A Earthwork shall be further densified and retested. Any retesting required shall be done at the expense of the Contractor. 3. Notification • Nofity the Engineer prior to placing any base course material and again prior to paving. B. Materials 1. Base Course The base course shall crushed aggregate base course (CABC) in accordance with NCDOT specifications for roads and structures, Section 910. This subgrade is to be maintained throughout the paving activity. 2. Pavement The pavement shall consist of 1 %2" bituminous concrete surface come, Type 1-2, placed in one layer. Bituminous concrete shall comply with the North Carolina State Highway Commission Standard Specifications for Roads and Structures, Section 645. C. Workmanship The paving operation shall comply in all respects with North Carolina State • Highway Standard Specifications .for Roads and Structures, latest edition. File:47/1612fa1xt Page 5 D. Execution • 1. Preparation of Subgrade When all excavated areas have been brought to grade and all embankment areas have been graded and compacted, the subgrade surface shall be checked by means of levels and templates for cross-section. If found correct, the entire subgrade shall then be rolled with a power roller weighing not less than ten (10) tons after which the cross-section shall again be checked by template and all inequalities remedied. Subgrade areas which yield under pressure shall be removed and replaced with suitable material. When rolling, checking, and re -rolling have been completed, the subgrade shall be considered ready to receive the base course. No base material shall be placed unless the subgrade is dry and firm. Before beginning construction of the base course, the subgrade shall have been prepared as directed above. Any settlement evident after base course has been placed shall be corrected as directed by the Engineer and at the Contractor's expense. 2. Placing CABC • Spread the CABC on the subgrade with a mechanical spreader capable of placing the materials to a uniform loose depth and without segregation, except that for areas in accessible to mechanical spreader, the CABC may be placed by other methods approved by the Engineer. No base material shall be placed on frozen subgrade or base. Hauling equipment shall not be operated on a previously completed layer of base material soft enough to rut or weave beneath the equipment. The Contractor shall utilize methods of handling, hauling, and placing which will minimize segregation and contamination. If segregation occurs, the Engineer may require that changes be made in the Contractoes method to minimize segregation and may also require mixing on the road which may be necessary to correct any segregated material. No additional compensation will be allowed for the work of road mixing as may be required under this provision.Aggregate which is contaminated with foreign materials to the extent the base course will not adequately serve its intended use, shall be removed and replaced by the Contractor at the direction of the Engineer at no additional cost to the Owner. The base shall be compacted to a density equal to at least one hundred percent (100) of that obtained by compacting a sample of the material in accordance with AASHTO. T 180. File:47/1612fs.txt Page 6 The base material shall be compacted at a moisture content which is approximately that required to project the maximum density indicated by the . above test method. The Contractor shall dry or add moisture to the material when required to provide a uniformity compacted and acceptable base. The base material shall be shaped to conform to the lines, grades and typical sections shown on the plans or established by the Engineer. When completedi the base course shall be smooth, hard, dense, unyielding and well bonded. A broom drag shall be used in connection with the final finishing and conditioning of the surface of the base course. 3. Reconditioning Compacted Areas Where completed compaction areas are disturbed by subsequent construction operations or adverse weather; scarify surface, reshape and compact to required density prior to further construction. 4. Maintenance of CABC The Contractor shall maintain the surface of the base by watering, machining and rolling or dragging when necessary to prevent damage to the base by weather or traffic. Where the base or subgrade is damaged, the Contractor shall repair the damaged area, reshape the base to the required lines, grade and sections and recompact the base to the required density. 5. Bituminous Concrete Paving The paving operation shall comply in all respects with NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, latest edition. The thickness tolerance for the in -place compacted bituminous concrete shall be plus or minus 1/4 inch. 6. Surface Smoothness Test finished surface of each asphalt concrete course for smoothness, using 10' straight edge applied parallel and at right angles to centerline of paved area. Surfaces will not be acceptable if exceeding the 3/16" tolerance for smoothness. E. Payment 9 Payment will be included in the contract price. File:47/1612fs.txt Page 7 Division 3 • Curb & Gutter A. Description The work includes construction of 24" standard concrete curb and gutter. B. Materials 1. Concrete Concrete shall meet requirements of North Carolina State Highway Commission Standard Specification for Roads and Structures, Section 900 for Class "B" Concrete. 2. Curb and Gutter Curb and gutter shall be 24"standard type. C. Workmanship • 1. All workmanship shall comply with North Carolina State Highway Commission Standard Specifications for Roads and Structures, latest edition. I* 2. The Contractor shall backfill curb and gutter as soon as practical. If the curb and gutter become misaligned due to failure of the Contractor to properly backfill the curb; then all misaligned curb and gutter shall be replaced at the Contractor's expense. 3. The Contractor shall take care not to disturb any structures in place. Any damage caused by his operation will be repaired at the Contractors expense. D. Notification Notify the Engineer at least twenty-four hours prior to placing curb and gutter. E. Payment Payment for curb and gutter will be included in the contract price. No additional payment will be made for backfilling. File:47/1612A.at Page 8 Division 4 Seeding & Mulching A. Description of Work Seed and mulch all areas which arc disturbed by the Contractor's operations and which are not to be covered by gravel or concrete. B. Products 1. The seed mixture shall comply with the seeding schedule attached. 2. All seed shall be labeled in accordance with U.S. Department of Agriculture "Rules and Regulations under the Federal Seed Act" in effect at date of purchase of seed. All seed shall be furnished in standard containers. Seed which has become moldy, wet`or otherwise damaged in transit or storage shall not be accepted. 3. Seed purity, germination and weed content shall comply with the following: Description Minimum Seed Purity Minimum Germination Maximum Weed Seed Sericea Lespenseza 98 85 0.50 KY31 Fescue 85 80 0.50 Pensacola Bahiagrass 80 1 70 1 1.00 Weeping Lovegrass 95 85 1.00 Korean Lespedeza 97 85 1.00 4. Lime Apply lime at the rate of two tons per acre. Lime shall be agriculture grade, ground limestone. Ground limestone shall contain not less than 88% of calcium carbonate content equivalent and shall be of a fineness to 90% will pass through a Number 10 sieve and not less than 50% through a Number 50 sieve. 5. Fertilizer Apply 1,000 pounds per acre; 10-10-20 or equivalent. All fertilizer shall be delivered in bags or other convenient standard containers with name of material, name of manufacturer, net weight and analysis on each bag or container. File:47/1612fs.txt Page 9 6. Mulch • Shall consist of small grain straw or tame hay, free of undesirable weed seed. Mulch shall be applied at the rate of 2 tons per acre. C. Grassing Procedure 1. Advance Preparation Areas to be graded shall be brought to the proper line, grade and cross section, as shown on the plans or as previously constructed before grassing operations are started. If any damage by erosion or other causes has occured after the completion of grading and before beginning the application of fertilizer and lime, the Contractor shall repair such damage. This shall include filling washes, smoothing irregularities and repairing other incidental damage. Minor shaping and smoothing of uneven and rough areas outside of the graded section shall be done as directed by the Engineer in order to provide for more effective erosion control and for ease of subsequent mowing operations. 2. Tillage All graded areas shall be thoroughly tilled to a depth of at least 4" by plowing, disking, harrowing or other approved methods until the condition of • the soil is acceptable. Where soil conditions are such that difficulty is encountered in getting clods and lumps effectively pulverized, the Contractor shall use rotary tillage machinery until the mixing of the soil is acceptable to the Engineer and no clods or lumps remain larger that 1 1 /2" in diameter. 3. Cleanup After completion of the tillage operation, the surface shall be cleared of stones, debris or other objects larger than 1 1/2" in thickness or diameter and, other objects that might become a hindrance to maintain operations. • 4. Applying Lime and Fertilizer Following the cleanup operation, lime and fertilizer shall be spread uniformly over the areas to be grassed and shall be thoroughly mixed with the soil to a depth of approximately 3". Fertilizer shall be applied at a rate of application specified herein before, unless otherwise directed. In all cases where practicable, approved mechanical spreaders shall be used for spreading fertilizer and lime. File:47/1612fs.CR Page 10 S. Seeding . Seed shall be sown within 24 hours following the application of fertilizer and lime as specified herein before. Seed shall be uniformly sown at the rate specified by the use of approved mechanical seeders. The seeds shall be covered and lightly compacted by means of a cultipacker or light roller. On slopes inaccessible to compaction equipment, the seed shall be covered by dragging spiked chains, by light harrowing or by other satisfactory methods. Within 36 hours following completion of seed application the entire area shall then be mulched and the mulch shall be anchored. 6. Hydraulic Seeders May be used for application of seed and fertilizer. Seed shall not remain in water containing fertilizer for more than 30 minutes prior to application unless otherwise permitted by the Engineer. 7. Maintenance The Contractor shall maintain seeded areas until an approved stand of • grass has been achieved. He shall add fertilizer or seed to bare areas as required and water and mow as necessary to acquire a good stand of grass. 8. Stand of Grass Required It is the intent of this specification that the Contractor be obligated to deliver a satisfactory stand of perennial grass. If this is necessary to repeat any or all of the work, including plowing, fertilizing, watering and seeding, the Contractor shall repeat these operations at no additional cost until a satisfactory stand is obtained. File:47/16122.txt Page 11 • Division 5 Site Grading A. Description of Work The work includes: 1. Stripping topsoil and stockpiling for later use. 2. Excavation and fill for driveways, parking, and building pad. B. Material 1. Fill Material Use only select material meeting the approval of the Engineer. Where material excavated from on site cut areas is determined by the Engineer to be suitable, it shall be used as fill. Suitable fill material shall generally consist of materials classified as A-1-a, A-1-6, A-24 or A-2-5 and not containing excessive moisture. Where suitable materials are not available on site, borrow material shall be furnished. Borrow shall generally meet the same requirements as specified above. 2. Base Material for Floor Slab The final four inches of fill below the floor slab shall be clean, coarse and sharp sand consisting of hard particles free from silt, salt or organic matter. C. Execution 1. Erosion and Sedimentation Control Prior to beginning any earth -disturbing activity the Contractor shall construct all silt fences, straw bale barriers and/or other erosion and sedimentation control devices as shown on the plans or as directed by the Engineer. 2. Stripping Shall consist of removing organic soils and root mats from the surface of all areas to receive special surface treatment including both asphalt and concrete surfaces. Depth of stripping shall be determined based on site conditions but the minimum depth shall generally be four inches. All material from stripping operations shall be stockpiled in designated area. File:47/1612Wxt Page 12 . 3. Rough Grading Generally site grading shall conform to the grades and contours shown on the plans. Tolerance for rough grades shall be +0.1 feet. Grade will be staked by the Engineer. 4. Proof Rolling After all portions of the site have been graded to finish grade the entire area shall be proof rolled in the presence of the Engineer. A fully loaded triaxle or tandem dump truck or a motor grader may be used for the proof rolling. Areas which yield under the roller pressure shall be undercut, filled with suitable material and compacted. 5. Building Area Subgrade Compaction After the building area has been stripped, roll the entire building area with a vibrating roller having a minimum static weight of 22,000 lbs. Make a total of eight passes, four in each direction at 90 degrees to each other. 6. Embankment Construction • Embankments shall be constructed using only suitable fill material as defined in paragraph B-1 above. 40 Embankments shall be built up in fill width from the bottom in successive layers not exceeding 12 inches thickness, loose depth with sides slightly higher than the centers:. Each layer shall be compacted with a vibrating roller, eight passes as specified in five above. 7. Different Site Conditions Should the Engineer determine that construction methods other than those specified herein are required to obtain the required compaction, then the price for such work shall be negotiated. 8. Density Testing Subgrades shall be compacted the following densities: Pavement Subgrades Building Footings Floor Slab File:47/1612fs.txt Page 13 95% Modified Proctor 95% Modified Proctor 90% Modified Proctor • Density test if required will be paid for by the Owner. Any retesting required due to improper compaction techniques will be paid for by the Contractor. :0 File:47/1612fs.txt Page 14 Division 6 Storm Drainage & Erosion Control A. Scope of Work 1. The work to be performed consists of famishing all tools, labor, materials, equipment, supplies and other things necessary to complete the construction of all storm drainage systems including incidental structures. 2. Underground Utilities and Structures Utilities and other existing underground structures shown on the drawings are shown for the purpose of indicating the existence of such utility or structure and no guarantee is given as to the exact location or the completeness of the information shown. It shall be responsibility of the Contractor to locate all such utilities and structures and to maintain service or promptly restore service, at his own expense, in the event interruption is caused by his operation. All utilities and structures that are uncovered by the excavation process and left in the trench shall be carefully supported and protected from injury by • the contractor's operation. At least 48 hours prior to beginning construction the Contractor shall notify Utilities Locating Company, Inc. (ULOCO) 1-800-6324949 in order that existing utilities in the area may be flagged and staked. B. Materials 1. Concrete Pipe Concrete pipe shall be reinforced concrete pipe, Class III or better, meeting all requirements of ASTM C-76, latest edition. Joints for concrete pipe shall be Ram-Nek type. 2. Drainage Structures File:47/1612fs.txt Comply with NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, Section 840-2. Page 15 • 3. Silt Fence Comply with. typical detail on the plans. 4. Stone Construction Entrance Comply with typical detail on plans. 5. Manhole Frames and Covers Manhole frames and covers shall be McKinley Type BM or approved equal.. 6. Catch Basin Frame and Grate Catch basin frame and grate shall be Dewey Brothers CH-BM-2001 or approved equal. 7. Drop Inlet Frame and Grate Drop inlet frame and grate shall be McKinley Type B or approved equal. • 8. Gravel Gravel shall be size three -fourths inch to one and one-half inch washed stone. C. Workmanship 1. Excavation Excavation in all cases shall conform to the line, depth, and grade as shown on the plans or as directed by the Engineer. A fum full length support shall be formed for all pipe and structures. 2. Shoring The Contractor shall furnish, put in place, and maintain such sheeting, bracing, etc. required to support the sides of the excavation and to prevent any movement which can in any way injure the masonry, diminish the necessary width of the excavation or otherwise. injure or delay the work of endanger adjacent buildings or other structures or create undue hazard to workmen employed therein. If the Engineering is of the opinion that at any point . sufficient or proper supports have not been provided, he may order additional File:47/161M.txt Page 16 • supports put in at the expense of the Contractor and the compliance with such orders shall not release the Contractor from his responsibility for the sufficiency of such support. Care shall be taken to prevent voids outside of the sheeting, but if voids are formed, they shall be immediately filled and rammed to the satisfaction of the Engineer. All sheeting and bracing that is removed from the backfill shall be removed in such a manner as not to endanger the constructed sewer or other structures, utilities or property, whether public or private. All voids left or caused by the withdrawal of sheeting shall be immediately refilled with earth as directed by the Engineer. 3. Dewatering The contractor shall remove by pumping, bailing or otherwise any water which may accumulate or be found in the trenches and other excavations made under this Contract and shall form all dames, flumes, or other works necessary to keep them entirely clear of water while the water lines, sewers, foundations, and structures are being constructed. Water from the trenches and excavations shall be disposed of in such a manner as will not cause injury to the work completed or in progress, to the public health, to public or private property, nor cause any interference with the use of the same by the public. Well point • system, if required, shall be installed and operated at the expense of the contractor. • 4. Backfilling All backfilling shall be compacted to the density of the adjoining undisturbed soils. Granular materials may be backfilled by flooding with water. 5. Finishing Grading Grading shall be accomplished by using only light weight equipment and by hand as necessary to prevent damage to the system. D. Inspection The Contractor shall not cover any work until it has been inspected by the Engineer. File:47/1612fuxt Page 17 • E. Execution 1. Pipe Installation • Comply with NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, Section 300. 2. Erosion Control Place rip -rap and silt fence as soon as possible. Contractor will be responsible for implementing erosion control measures as designated on plans. File:47/1612fs.to Page 18 - • Division 7 Water Distribution System A. General 1. Description of Work Work to be performed under this section consists of furnishing all, tools, labor, materials, equipment, supplies and other things necessary to construct the water distribution system including all mains and appurtenances. 2. Underground Utilities and Structures Utilities and other existing underground structures shown on the drawings are shown for the purpose of indicating the existence of such utility or structure and no guarantee is given as to the exact location or the completeness of the information shown. It shall be the responsibility of the Contractor to locate all such utilities and structures and to maintain service or promptly restore service, at his own expense, in the event interruption is caused by his operation. All utilities and structures that are uncovered by the excavation process and left in the trench shall be carefully supported and protected from injury by the Contractor's operation. At least 48 hours prior to beginning construction the Contractor shall notify Utilities Locating Company, Inc. (ULOCO) - Tel: 1-800-632-4949 in order that existing utilities in the area may be flagged and staked. 3. Notification Notify the Town of Beaufort (Te1:728-2141) and the Engineer (Tel: 247-7479) at least 48 hours prior to beginning work. B. Materials 1. Ductile Iron Pipe (DIP) - All Sues File:47/1612fs.txt Ductile iron pipe shall be Class 50 unless otherwise specified, conforming to the most recent revision of AWWA Standard C-151 (ANSI A 21.51) and shall be cement lined in accordance with the most recent revision of AWWA Standard C-104 (ANSI A 21.4). Pipe may be mechanical or push -on Page 19 • joint in accordance with AWWA Standard C-1 I I (ANSI A 21.11) unless otherwise specified. Standard. length shall be 18 feet. 2. PVC Pipe - All Sizes Polyvinyl chloride pipe shall be Class 200 conforming to ASTM D-1784 and D-2241. Joints shall be integral bell with rubber gaskets conforming to ASTM D-3134 and F-477. The pipe shall be SDR21 and shall bear the National Sanitation Foundation seal for potable water. 3. Gate Valves - 2" and Larger Valves shall be iron body, fully bronze mounted double disc, parallel seat with mechanical joints. Valves shall be of the nonrising.stem type with 2" square operating nuts. Valves shall open counterclockwise and be equipped with "O" ring seals in accordance with the most recent revision of AWWA Standard C-500. Valves shall be manufactured by Mueller, American Darling or Clow Corp. 4. Valve Boxes Valve boxes shall consist of cast iron telescoping, top and bottom • sections with cover marked "WATER". The sections shall be adjustable for different burying depths. Valve boxes shall be Dewey Brothers VBX-TE-100 or approved equal. Extensions, if necessary, shall be provided through the addition of one bottom section and an appropriate of 6" C.I. soil pipe. 5. Fittings Tees, elbows and other fittings in 4" size or greater shall be of ductile mechanical joint or push on joint, cement lined, meeting the most recent revisions of AWWA Standard C-110 (ANSI A 21.10) and shall be designed for a minimum working pressure of 150 psi. Fittings for 2" PVC shall conform to the ASTM Standards for 2" PVC pipe and be rubber gasket -bell type joint. 6. Hydrants - 5 Y4" Hydrants shall be cast iron body with "O" ring seals and bronze to bronze threads on the seat ring and drain ring housing. The hydrant shall be designed for 150 psi working pressure as manufactured by Mueller or American Darling in accordance with the latest AWWA Standard (C-502). Hydrants shall be provided with two 2%2 inch outlets and a 4%2 inch pumper nozzle having National Standard thread. Hydrants shall have the traffic breakable feature. Hydrants shall be so designed that when it is in place, no • excavation or tension wrenches are required to remove the main valve and File:47/1612fs.cet Page 20 • movable parts of the drain valve. Hydrants shall have a main valve of 5'/, inch diameter and an inlet size of 6 inch diameter with mechanical joint fitting. The operating nut shall be National Standard and shall open counterclockwise. Color shall be fire hydrant red above the ground line. 7. Tapping Valves Tapping valves shall meet all of the requirements of 4 above except that only one side of the valve shall have a mechanical joint fitting; the other shall be flanged: 8. Service Tap C/." and 1") for PVC and DIP Corporation stops shall be Ford F-1000, Mueller 15008 or approved equal. Service clamps, if used, shall be of bronze construction as manufactured by Mueller or approved equal. All corporation stops shall be machine installed in accordance with the manufacturer's recommended procedures. 9. Service Clamp Double strap service clamps or saddlestraps shall be used on all 2" PVC pipe. Service clamps shall be of bronze construction and equal to that • manufactured by Mueller Company, Ford Meter Box Co. or approved equal. All corporation stops or saddlestops shall be installed in accordance with the manufacturer's recommended procedures. 11 10. Service Pipe The service pipe from water mains shall be plastic municipal service line pipe, 160 pound class, in conformance with ASTM Specification D-2737. The pipe shall be supplied in 300 feet coils and no joint or coupling shall be installed between the main service tap and the meter stop. Plastic stiffeners shall be supplied for connecting service pipe to corporation stops and meter valves. 11. Meter Setters Meter setters shall be as manufactured by Mueller or Ford. 12. Meter Boxes Meter boxes may be plastic with cast iron lids. File:47/1612fuxt Page 21 • C. Workmanship 1. Excavation Excavation of trenches for water lines shall comply with details as shown on plans. Any excavation below the specified level shall be backfilled with sand, gravel or other approved material at the Contractor's expense and such material shall be tamped to the satisfaction of the Engineer. The sides of trenches in cohesive soils shall be vertical and their widths shall be no less than 6 inches nor more that 8 inches on each side of the pipe bell or trenches may be excavated to widths recommended by the pipe manufacturers. The bottom of the trench at the bells shall be excavated by hand to accurately fit the bells. The Contractor shall remove all water accumulated in the trench in a manner approved by the Engineer. 2. Pipe Installation All pipe shall be installed in accordance with pipe manufacturers recommendation. • Pipe fittings and valves shall be handled in a manner which will prevent damage and while they are suspended over the trench they shall be inspected for defects and rung with a light hammer to detect cracks. 0 Before the pipe is laid it shall be examined for defects and all dirt and loose material of any sort shall be removed. After the pipe is in place the Contractor shall keep trench free of standing water and other foreign materials. Concrete blocking shall be installed.to prevent movement of valves and fittings. Method of blocking shall be subject to the approval of the Engineer. 3. Valve Boxes Valves shall be set plumb with the box directly over the valve and placed in such a manner so as not to place any undue stresses of pressure on any part of the pipe or valves and in such a manner that the valves may be easily opened and closed from the ground surface. The Contractor shall adjust valve boxes to final grade at the time designated by the Engineer. No additional compensation will be made for valve box adjustment. File:47/1612fuxt Page 22 U] 4. Horizontal Separation Water mains shall be laid at least 10 feet, horizontally, from any existing or proposed sewers. Should local conditions prevent a lateral separation of 10 feet, water mains may be laid closer than 10 feet to a sewer if, the elevation of the top (crown) of the sewer is at least 18" below the bottom (invert) of the water main and if: a. It is laid in a separate trench, or if; b. It is laid in the same trench with the sewers located at one side on a bench of undisturbed earth. 5. Vertical Separation Whenever water mains must cross above sewers, the water mains shall be laid at such an elevation that the bottom of the water main is at least 18" above the top of the sewer. When it is impossible to obtain proper horizontal and vertical separation as stipulated above, both the water main and sewer shall be constructed of mechanical joint ductile iron pipe for a distance of 10 feet each side of the point of intersection. One full length of water main shall be centered on the sewer. 6. Backfill Backfill shall comply with detail drawings as shown on plans. Backfill shall be placed around pipe and up to 12 inches above the top of the pipe and compacted using hand operated equipment. Backfill in this area shall be made only with select material free .of large clods, stones, roots, excessive moisture or other objectionable material. The backfill material in all cases shall be subject to the Engineers approval. Compaction methods will be at the option of the Contractor except that heavy equipment will not be permitted to operate over the water line until a minimum cover of at least 3 feet has been obtained. Compaction by flooding with .water will be permitted in non -cohesive soils. If at any time, however, the Engineer is of the opinion that the compaction requirements are not being met, he may order a compaction test to be conducted by a qualified soils testing lab. Laboratory method for determination of maximum density shall be in accordance with ASTM D-1556 sand cone method. Other methods of field determination of density may be used only with the approval of the Engineer. Initial tests for density will be at the expense of the owner. If the tests show inadequate compaction, then the Contractor shall reconstruct the backfill File:47/1612ftixt Page 23 • and fumish additional compaction tests at his own expense. The backfill will not be accepted until the compaction tests have passed. 7. Hydrostatic Tests The Contractor, shall provide all necessary equipment and shall perform all work required in connection.with the tests. The water main shall be filled and subjected to a hydrostatic pressure 50% in excess of the normal working pressure, but not less that 150 psi. The pipe shall be slowly filled with water, care being taken to expel all air from the pipes. If necessary, the pipes shall be tapped at high points to vent the air. The cost of taps to vent the air shall be included in the unit prices bid for PVC. The required pressure as measured at the point of lowest elevation shall be applied for not less than two hours and all pipe fittings, valves and points shall be carefully examined for.defects. The pipe installation will not be accepted unless and until the leakage (elevation on a pressure basis of 150 psi) is less than the maximum allowable leakage set forth in Section 13 of AWWA Standard C-600, latest edition S. Flushing • The water main shall be flushed in accordance with AWWA Standard C-601, latest edition. Flushing_of each section of the line shall continue until sufficient time has elapsed for movement of water from one end of the section to the other end of the section. The cost of flushing the mains, including all temporary connections, shall be included in the bid for pipe. 9. Sterilization All water supply mains shall be sterilized by the Contractor. No extra payment will be provided as this work is considered to be an element of other work units. The sterilization process shall be in conformance with the standards of the NC State Board of Health and AWWA Standard C-601, latest edition. The system shall be disinfected with a 50 ppm dosage of chlorine. Treated water shall be retained in the lines for not less than 24 hours and shall produce not less that 10 ppm chloride concentration in the extreme ends of the distribution system at the conclusion of the retention period. Calcium hypochlorite may be used. During the chlorination process all valves and accessories shall be operated. After flushing and refilling the main, the File:47/1612fs.txt Page 24 • Inspector will secure a sample of water from the end of the main and submit to an environmental laboratory approved by the State of North Carolina which will perform a bacteria analysis. The lines will not be accepted until analysis shows no bacteria. 10. Surface Restoration The surfacing of all roads, yards or ditches, etc. that is disturbed or damaged by any of the Contractors operations shall be restored to its original state. Surfacing shall be taken.to mean clay, gravel, grass hardtop or any other specially treated surface. 11. "As -Built" Drawing A drawing showing the station numbers of all valves, fittings and services shall be fumished by the Contractor before final payment is approved. Measurements shall be made beginning at a valve at street intersections and continue to increase to the end of the water line or to the next valve. A Guarantee The Contractor shall guarantee. all materials and workmanship for a period of • one year from the date of acceptance by the Town of Beaufort. • E. Basis of Payment Payment shall be at based on the Engineer's measurements. File:47/1612ils.ty Page 25 Division 8 Sewer System A. General 1. Description of Work Work to be performed under this section consists of furnishing all, tools, labor, materials, equipment, supplies and other things necessary to complete the construction of sanitary sewer lines, services and, appurtenances. 2. Underground Utilities and Structures Utilities and other existing underground structures shown on the drawings are shown for the purpose of indicating the existence of such utility or structure and no guarantee is given as to the exact location or the completeness of the information shown. It shall be the responsibility of the Contractor to locate all such utilities and structures and to maintain service or promptly restore service, at his own expense in the event interruption is caused by his operation. All utilities and structures that are uncovered by the excavation process and left in the trench shall be carefully supported and protected from injury by the Contractor's operation. At least 48 hours prior to beginning construction the Contractor shall notify Utilities Locating Company, Inc. (ULOCO) - 1-800-632-4949 in order that existing Utilities in the area may be flagged and staked. 3. Notification Notify the Town of Beaufort (Tei:728-2141) and the Engineer (Tel: 247-7479) at least 48 hours prior, to beginning work. 4. Preconstruction Conference No work shall begin until a preconstruction conference has been held. The Engineer will notify the Contractor of the time and place for the preconstruction conference. File:47/1612fs.txt Page 26 • B. Materials 1. PVC Sewer Pipe Sewer pipe shall be PVC plastic pipe and shall conform to ASTM D-3033 or D-3034, latest edition with wall thickness to conform to SDR 35. Joints shall be push on elastomeric ring gasket type as per ASTM D-3212, latest edition. Use in -line wye fittings for house services. 2. Ductile Iron Pipe (DIP) - All Sizes Ductile iron pipe shall be Class 50 unless otherwise specified, conforming to the most recent revisionof AWWA Standard C-141 (ANSI A 21.51) and shall be cement lined in accordance with the most recent revision of AWWA Standard C-104 (ANSI A 21.4). Pipe may be mechanical or push -on joint in accordance with AWWA Standard C-I I (ANSI A 21.11) unless otherwise specified. Standard length shall be 18 feet. Pipe shall be cement mortar lined and exterior coated with 1.0 mil bituminous material in accordance with AWWA C-151. 3. PVC Service Pipes and Fittings • PVC service pipes shall be standard SCH 40 with in -line SDR35 fittings. Transition coupling shall be utilized at the in -line fitting to convert from SDR35 to SCH 40 and shall be made of SCH 40 PVC. 4. Brick Brick used in the work shall conform to ASTM C-32 and shall be laid with full shove joints. All joints shall be thoroughly filled with mortar and the thickness of joints on the inside of the walls must be more than three -eights (3/8) of an inch. 5. Concrete Blocks Concrete blocks for manholes, when specified, shall conform to ASTM C-139. 6. Manhole Frames and Covers Manhole frames and covers shall be Dewey Brothers, Inc. MH-RCR-2001-ECWG or approved equal. Solid covers with concealed pick holes shall be provided unless otherwise specified. In non -traffic areas, • MH-RCR-2001 may be used. File:47/1612fs.txt Page 27 • Frame and cover shall be made from class 30 gray cast iron conforming to the requirements of ASTM-A48 (latest revision thereof). The words "Sanitary Sewer" shall be cast into the cover. In addition both the manufacturer's name and casting number must be cast into the frames. 7. Reinforced Concrete Concrete used in the structures shall be Class A, 3,000 pound test, in accordance with Section 900, North Carolina State Highway Standard Specifications. Reinforcing steel shall conform to ASTM A-615 Grade 60. 8. Manholes Manholes shall be precast and have monolithic bottom sections. Manholes shall conform to latest ASTM C-478 specifications. Top slabs when used, shall be satisfactory for H-20 highway loading. Joints shall be watertight and conform to either the latest ASTM C-443 specifications for "O" ring joints or the latest ASTM C-478 specifications for section joints designed for cold applied sealing compound. Sealing compound.'shall be CPS-210 as manufactured by Concrete Products Supply Company or CS-102 as manufactured by Concrete Sealants. • Points of exit and entry for all pipe shall be provided with flexible manhole sleeves and two stainless steel take up clamps in accordance with ASTM C-923. Points of exit and entry for services shall be provided by 4" or 6" holes preformed into manhole and specifically designed for service connections. Manholes with preformed invert channels and benches may be utilized. When using these preformed bases, compression type polyurethane pipe joints in accordance with ASTM C-425 may be preformed in the manhole for pipe entrances and exits located in the manhole bottom invert instead of providing flexible sleeves. Contractor shall provide double stainless steel straps for connection of boot to pipe. Manholes indepth shall be set on crushed aggregate of at least I foot depth. All pinholes shall be filled with non -shrink grout. 9. Manholes Steps Manhole steps shall be three -eights (3/8) inch or larger steel reinforcing bar encased in rubber or plastic coating resistant to deterioration and chemical action. File:47/1612fs.txt Page 28 • 10. Transition Couplings Pipe material changes between manholes may be permitted provided there is not a substantial difference in inside diameters, and a smooth uniform flow line is maintained, and a watertight rubber sleeve, mechanical conforming the ASTM C 425 is used to make the transition. All metal hardware shall be stainless steel. C. Performance 1. General Installation of sewer mains shall be in conformance with specific recommendations of the pipe manufacturer. 2. Trench Excavation Trench excavation shall conform to the line and depth shown on the plans or as directed by the Engineer. The trench section shall comply with specification details as shown on plans. 3. Dewatering • The Contractor shall remove by pumping, bailing or otherwise any water which may accumulate or be found in the trenches and other excavations and shall form all dams, flumes or other works necessary to keep them entirely clear of water while sewers, foundations and structures are being constructed. Water from the trenches and excavations shall be disposed of in such a manner as will not cause injury to the work completed or in progress, to the public health, to public or private property, nor cause any interference with the use of the same by the public. • When it is necessary to excavate a drainage trench from an excavation site to a natural watercourse in lieu of pumping or bailing, such trenching work shall be done by the Contractor.at his own expense. The Contractor shall provide silt fences or other erosion control devices which may be required by the Engineer. Well points shall be famished by the Contractor if required for dewatering. The cost of well points shall be included in the unit price bid for sewer pipe File:47/161M.bn Page 29 • 4. Laying Sewer Pipe a. Methods of bedding under various trench conditions shall be as shown in Specifications under detail drawings shown on plans. b. The pipe shall be stored and installed in accordance with the manufacturer's recommendations and the requirements of these specifications. c. Sewer mains and manholes shall be laid to the line and grade shown on the plans. No deviations from line and grade shall be made unless they have been approved by the Engineer. d. Laser equipment shall be used by the Contractor for maintaining proper grade for laying pipe in.lieu of batter boards. e. The sewer pipe installation shall start at the outlet end and proceed upstream to the termination of the project as shown on the plans. f. While working on any part of an existing sewer main or manhole, the Contractor shall maintain the existing sewage flow. • g. After the trench foundation has been properly graded the pipe shall be carefully lowered into the trench with approved methods. Under no circumstances shall the pipe or accessories be dropped or dumped into the trench. All damaged pipe shall be properly repaired or replaced at the Contractor's expense. h. The pipe interior shall be kept clean before and after laying. Pipe ends shall be plugged at the end of each work day or when work is temporarily stopped. The plugs shall be watertight so that water and debris will be kept out. i. Where conditions are, in the opinion of the Engineer or Inspector, unsuitable for laying pipe because of weather or trench conditions, the Contractor shall be required to cease work until permission is given for work to commence again. 5. Sewer Service Laterals a. All 4" pipe shall be laid with a minimum allowable grade of 1%. b. Trench support, bedding and backfill for laterals shall conform to the same specifications as those for sewer mains, except that stone bedding • will be required under laterals only when specifically directed by the File:47/1612fs.txt Page 30 • Engineer. The Contractor shall properly backfill under all Wye and lateral connections at the main. 6. Manholes a. Manhole construction shall conform to standard details as shown on plans. b. All joints shall be filled using non -shrink grout applied in accordance with manufacturers instructions. C. Cold weather construction shall be confined to those days when the temperature is a minimum of 34 degrees F. Approval to work in no way relieves the Contractor of liability for damage due to freezing. d. The Contractor shall adjust manhole tops to final grade at the time designated by the Engineer. No additional compensation will be made for manhole adjustments. 7. Shoring The Contractor shall finish, put in place and maintain such sheeting, .• bracing, etc., as may be required to support the excavation and to prevent any movement which can in any way injure the masonry, or otherwise injure or delay the work or endanger adjacent buildings or other structures or create undue hazards to workmen employed therein. If the Engineer is of the opinion that at any point sufficient or proper supports have not been provided, he may order additional supports put in at the expense of the Contractor, and the compliance with such orders shall not release the Contractor from his responsibility for the sufficiency of such support. Care shall be taken to prevent voids outside of the sheeting, but if voids are formed, they shall be immediately filled and rammed to the satisfaction of the Engineer. All sheeting and bracing that is removed from the backfill shall be removed in such a manner as not to endanger the constructed sewer of other structures, utilities or property, whether public or private. All voids left or caused by the withdrawal of sheeting shall be immediately refilled with earth as directed by the Engineer. 8. Horizontal Separation Sewers shall be laid at least 10 feet, horizontally, from any existing or proposed water mains. Should local conditions prevent a lateral separation of 10 feet, a sewer may be laid closer than 10 feet to a water main if the elevation of the top (crown) of the sewer is at least 18" below the bottom (invert) of the • water main and if: File:47/16IMut Page 31 • a. It is laid in a separate trench, or if b. It is laid in the same trench with the water mains located at one side on a bench of undisturbed earth. 9. Verticial Separation Whenever the sewer must cross under the water mains, the sewer shall be laid at such an elevation that the top of the sewer is at least 18" below the bottom of the water main. When the elevation of the sewer cannot be varied to meet the above requirements, the water main shall be relocated to provide this separation. When it is impossible to obtain proper horizontal and vertical separation as stipulated above, both water main and sewer shall be constructed of mechanical joint ductile iron pipe for a distance of 10 feet each side of the point of intersection. One full length of water main shall be centered on the sewer. 10. Backfilling Backfilling of trenches after pipe installation shall comply with • specifications details as shown on plans except as follows: In areas which are not to be paved or receive any special surface treatment, the backfill from the bottom of the trench to a point one foot above the top of the pipe shall be placed as shown on the details, but material and compaction requirements for the remainder of the backfill may be varied with the approval of the Engineer. The method of obtaining the required compaction shall be at the Contractors option. Flooding with water is an acceptable method for coarse sand. Minimum compaction for utilities under pavement shall be 95%. 0 If at any time, however, the Engineer is of the opinion that the compaction requirements are not being met, he may order a compaction test to be conducted by a qualified soils testing lab. Laboratory method for determination of maximum density shall be in accordance with ASTM D-1557, modified proctor. Field determination of density shall be in accordance with ASTM D-1556, sand cone method. Other methods of field determination of density may be used only with the approval of the Engineer. Compaction testing shall be provided if requested by Town of Beaufort. Initial tests for density will be at the expense of the owner. If the tests show inadequate compaction, then the Contractor shall reconstruct the backfill and furnish additional compaction tests at his own expense. The backfill will not be accepted until the compaction tests have passed. File:47/1612fs.to Page 32 • The use of stone as a bedding material is required under manholes, structure foundations and pipe bedding. 11. Surface Restoration The surfacing of all roads, yards or ditches, etc., that is disturbed or damaged by any of the Contractor's operations shall be restored to it's original state. Surfacing shall be taken to mean clay, gravel, grass, hardtop or any other specially treated surfaces. 12. Rate of Progress Without permission from the Engineer no more that 300 feet of trench may be opened in advance the completed work in any section, and in all cases, the work of excavating, pipe laying and backfilling must move forward at approximately equal rates of progress. 13. Inspection Sewer lines shall be visually inspected from every manhole by use of mirrors, television cameras, or other devices for visual inspections and the lines shall all exhibit a fully circular pattern when viewed from one manhole to the • next. Lines which do not exhibit a true line and grade or have structural defects shall be corrected to meet these specifications. 14. Infiltration/Exfiltration Testing All construction of sewer facilities shall be of such quality that there shall be no perceptible inffltration/exffltration of water at any single location. The total infiltration/exfiltration shall in no case exceed 100 gallons per inch of diameter, per mile of pipe per day. Infiltration/cxfittration testing shall be observed by a Town of Beaufort representative. 15. Clean Up Upon completion of each section of line, it shall be the responsibility of the Contractor to "clean up" the construction site. Clean up shall consists of removing all rubbish, debris, unused materials, etc. from the construction site, leveling the area and, as far as practical, restoring the area to its "original" condition. The entire project site clean up work shall be accomplished to the satisfaction of the Engineer. File:47/1612fs.txt Page 33 • D. Record Drawings a The Contractor will keep one record copy of all Specifications, Drawings, Addenda, Modifications and Shop Drawings at the site in good order and annotated to show all changes made during the construction process. These shall be available to the Engineer and shall be delivered to him upon completion of the project. Annotations on the Drawings shall include the exact locations of each residential service stub in relation to the next lowest manhole and centerline of street. Length of service shall also be shown. E. Guarantee The Contractor shall guarantee all materials and workmanship for a period of one year from the date of acceptance by the Town of Beaufort. F. Basis of Payment Gravity sewer lines will be paid for at the contract price. File:47/1612fs.txt Page 34 • JUL-18-96 THU 15:13 PAK^UM & SHIP"UM ETC 904387227E P.01 Paul P. Davidson,. 4407 Ortega Forest Driv, Jacksonville, FL 32210 Post-ItT" brand fax transmittal merno 7671 1 aor pages . I Fro`m1 ` u ` co. co. Dept. Phone M FAx M 10 r. ?��I / e /s'9G STROUD ENGINEERING, P.A. Hestron Plaza One Suite 102 MOREHEAD CITY, NORTH CAROLINA 28557 (919) 247-7479 F G� G 0 doe 16/2 F.Zom7-5rTIrc 7f4 8.2C SHEET NO. CHECKED PM] a J iPdgCi T1 I RNkV Am IIp�I nv wlrc.4abn,Wss. 011il. is Ph�RNrt 11M1 iPEF IdOnIIS®0 • STROUD ENGINEERING, P.A. Hestron Plaza One Suite 102 MOREHEAD CITY, NORTH CAROLINA 28557 (919) 247-7479 ti SHEET NC. 2 CALCULATED BY v CHECKED BY 6 fl1=E N I ISgbSj �1 ICI®.k. .Mm.01111. To rFf E TML MEE I M}Y1551M I I 10 64 STROUD ENGINEERING, P.A. JOB M / Hestron Plaza One SHEET NO. Suite 102 MOREHEAD CITY, NORTH CAROLINA 28557 CALCULATED (919) 247-7479 • CHECKED BY SCAT F III f C :.0 doefficient re 2 Bottom iArea I (sf) midway 'Ar6a (sf) Q11Y47 IN A'— ,o IF BYOILTm 1 cSooSb`nW ®®In. ftm,WS3 01471 To "rFflWT().L FREE 1 VnoAN 0 9 C:\PBWORKS\DOC\826.PSS Outlet Control DeviceCd= 0.72 D(ft.)= 0.08333 A= 0.00545 Inc. Sum Time h Vole. (min.) (min) (hrs.) (ft.) (cf) 30 30 0.5 1.900 6600 30 60 1 1.900 6600 30 90 1.5 1.878 6522 30 120 2 1.855 6444 30 150 2.5 1.833 6367 30 180 3 1.811 6290 30 210 3.5 1.789 6214 30 240 4 1.767 6138 30 270 4.5 1.745 6063 30 300 5 1.724 5988 30 330 5.5 1.702 5913 30 360 6 1.681 5839 30 390 6.5 1.660 5766 30 420 7 1.639 5693 30 450 7.5 1.618 5620 30 480 8 1.597 5548 30 510 8.5 1.577 5477 30 540 9 1.556 5405 30 570 9.5 1.536 5335 30 600 10 1.516 5264. 30 630 10.5 1.495 5195 30 660 11 1.475 5125 30 690 11.5 1.456 5056 30 720 12 1.436 4988 30 750 12.5 1.416 4920 30 780 13 1.397 4853 30 810 13.5 1.378 4786 V= Inc.= h= Q Vout (cfs) (cf) 0.0434 0.0434 78.14 0.0432 77.68 0.0429 77.22 0.0426 76.75 0.0424 76.29 0.0421 75.82 0.0419 75.36 0.0416 74.90 0.0414 74.43 0.0411 73.97 0.0408 73.50 0.0406 73.04 0.0403 72.58 0.0401 72.11 0.0398 71.65 0.0395 71.18 0.0393 70.72 0.0390 70.26 0.0388 69.79 0.0385 69.33 0.0383 68.86 0.0380 68.40 0.0377 67.93 0.0375 67.47 0.0372 67.01 0.0370 66.54 - 1 - 7/3/96 8:36:27 6600 30 1.9 Vnew Q avg (cf) (cfs) 6600.,0 0.0434 6521.9 0.0434 6444.2 0.0433 6367.0 0.0432 6290.2 0.0431 6213.9 0.0430 6138.1 0.0429 6062.7 0.0427 5987.8 0.0426 5913.4 0.0425 5839.4 0.0424 5765.9 0.0422 5692.9 0.0421 5620.3 0.0420 5548.2 0.0418 5476.6 0.0417 5405.4 0.0416 5334.7 0.0415 5264.4 0.0413 5194.6 0.0412 5125.3 0.0411 5056.4 0.0410 4988.0 0.0408 4920.1 0.0407 4852.6 0.0406 4785.6 0.0404 4719.1 0.0403 SHs 7- s7 % 7 dv / 9 • • C:\PBWORKS\DOC\826.PSS 30 840 14 1.359 4719 30 870 14.5 1.339 4653 30 900 15 1.321 4587 30 930 15.5 1.302 4522 30 960 16 1.283 4458 30 990 16.5 1.265 4393 30 1020 17 1.246 4330 30 1050 17.5 1.228 4266 30 1080 18 1.210 4203 30 1110 18.5 1.192 4141 30 1140 19 1.174 4079 30 1170 19.5 1.157 4018 30 1200 20 1.139 3957 30 1230 20.5 1.122 3896 30 1260 21 1.104 3836 30 1290 21.5 1.087 3777 30 1320 22 1.070 3718 30 1350 22.5 1.053 3659 30 1380 23 1.037 3601 30 1410 23.5 1.020 3543 30 1440 24 1.003 3486 30 1470 24.5 0.987 3429 30 1500 25 0.971 3373 30 1530 25.5 0.955 3317 30 1560 26 0.939 3261 30 1590 26.5 0.923 3206 30 1620 27 0.907 3152 30 1650 27.5 0.892 3098 30 1680 28 0.876 3044 30 1710 28.5 0.861 2991 30 1740 29 0.846 2939 30 1770 29.5 0.831 2887 30 1800 30 0.816 2835 0.0367 66.08 0.0365 65.61 0.0362 65.15 0.0359 64.68 0.0357 64.22 0.0354 63.76 0.0352 63.29 0.0349 62.83 0.0346 62.36 0.0344 61.90 0.0341 61.43 0.0339 60.97 0.0336 60.51 0.0334 60.04 0.0331 59.58 0.0328 59.11 0.0326 58.65 0.0323 58.18 0.0321 57.72 0.0318 57.25 0.0316 56.79 0.0313 56.33 0.0310 55.86 0.0308 55.40 0.0305 54.93 0.0303 54.47 0.0300 54.00 0.0297 53.54 0.0295 53.07 0.0292 52.61 0.0290 52.14 0.0287 51.68 0.0285 51.21 9 - 2 - 7/3/96 8:37:18 4653.0 0.0402 4587.4 0.0401 4522.2 0.0399 4457.5 0.0398 4393.3 0.0397 4329.6 0.0395 4266.,3 0.0394 4203.4 0.0393 4141.1 0.0392 4079.2 0.0390 4017.8 0.0389 3956.8 0.0388 3896.3 0.0386 3836.2 0.0385 3776.7 0.0384 3717.5 0.0383 3658.9 0.0381 3600.7 0.0380 3543.0 0.0379 3485.7 0.0377 3429.0 0.0376 3372.6 0.0375 3316.8 0.0373 3261.4 0.0372 3206.4 0.0371 3152.0 0.0370 3098.0 0.0368 3044.4 0.0367 2991.4 0.0366 2938.7 0.0364 2886.6 0.0363 2834.9 0.0362 2783.7 0.0361 sH�FFr-X','k c9 /i U E 0 C:\PBWORKS\DOC\826.PSS 30 1830 30.5 0.801 2784 30 1860 31 0.787 2733 30 1890 31.5 0.772 2683 30 1920 32 0.758 2633 30 1950 32.5 0.744 2583 30 1980 33 0.730 2535 30 2010 33.5 0.716 2486 30 2040 34 0.702 2438 30 2070 34.5 0.688 2391 30 2100 35 0.675 2344 30 2130 35.5 0.661 2297 30 2160 36 0.648 2251 30 2190 36.5 0.635 2205 30 2220 37 0.622 2160 30 2250 37.5 0.609 2116 30 2280 38 0.596 2071 30 2310 38.5 0.584 2027 30 2340 39 0.571 1984 30 2370 39.5 0.559 1941 30 2400 40 0.547 1899 30 2430 40.5 0,535 1857. 30 2460 41 0.523 1816 30 2490 41.5 0.511 1775 30 2520 42 0.499 1734 30 2550 42.5 0.488 1694 30 2580 43 0.476 1654 30 2610 43.5 0.465 1615 30 2640 44 0.454 1577 30 2670 44.5 0.443 1538 30 2700 45 0.432 1501 30 2730 45.5 0.421 1463 30 2760 46 0.411 1427 30 2790 46.5 0.400 1390 0.0282 50.75 0.0279 50.29 0.0277 49.82 0.0274 49.36 0.0272 48.89 0.0269 48.43 0.0266 47.96 0.0264 47.50 0.0261 47.03 0.0259 46.57 0.0256 46.10 0.0254 45.64 0.0251 45.17 0.0248 44.71 0.0246 44.24 0.0243 43.78 0.0241 43.31 0.0238 42.85 0.0235 42.38 0.0233 41.92 0.0230 41.45 0.0228 40.99 0.0225 40.52 0.0223 40.06 0.0220 39.59 0.0217 39.12 0.0215 38.66 0.0212 38.19 0.0210 37.73 0.0207 37.26 0.0204 36.80 0.0202 36.33 0.0199 35.87 - 3 - 7/3/96 8:38:03 2733.0 0.0359 2682.7 0.0358 2632.9 0.0357 2583.5 0.0355 2534.6 0.0354 2486.2 0.0353 2438-2 0.0352 2390.7 0.0350 2343.7 0.0349 2297.1 0.0348 2251.0 0.0346 2205.4 0.0345 2160.2 0.0344 2115.5 0.0343 2071.3 0.0341 2027.5 0.0340 1984.2 0.0339 1941.3 0.0337 1898.9 0.0336 1857.0 0.0335 1815.6 0.0334 1774.6 0.0332 1734.1 0.0331 1694.0 0.0330 1654.4 0.0328 1615.3 0.0327 1576.6 0.0326 1538.5 0.0324 1500.7 0.0323 1463.5 0.0322 1426.7 0.0321 1390.3 0.0319 1354.5 0.0318 • C:\PBWORKS\DOC\826.PSS 30 2820 47 0.390 1354 30 2850 47.5 0.380 1319 30 2880 48 0.370 1284 30 2910 48.5 0.360 1250 30 2940 49 0.350 1216 30 2970 49.5 0.340 1182 30 3000 50 0.331 1149 30 3030 50.5 0.321 1116 30 3060 51 0.312 1084 30 3090 51.5 0.303 1053 30 3120 52 0.294 1021 30 3150 52.5 0.285 991 30 3180 53 0.276 960' 30 3210 53.5 0.268 931 30 3240 54 0.259 901 30 3270 54.5 0.251 872 • 30 3300 55 0.243 844 ' 30 3330 55.5 0.235 816 30 3360 56 0.227 789 30 3390 56.5 0.219 762 30 3420 57 0.212 735 30 3450 57.5 0.204 709 30 3480 58 0.197 683 30 3510 58.5 0.189 658 30 3540 59 0.182 633 30 3570 59.5 0.175 609 30 3600 60 0.169 586 30 3630 60.5 0.162 562 30 3660 61 0.155 539 30 3690 61.5 0.149 517 30 3720 62 0.143 495 30 3750 62.5 0.136 474 30 3780 63 0.130 .453 9 0.0197 35.40 0.0194 34.93 0.0191 34.47 0.0189 34.00 0.0186 33.54 0.0184 33.07 0.0181 32.61 0.0179 32.14 0.0176 31.67 0.0173 31.21 0.0171 30.74 0.0168 30.28 0.0166 29.81 0.0163 29.34 0.0160 28.88 0.0158 28.41 0.0155 27.94 0.0153 27.48 0.0150 27.01 0.0147 26.54 0.0145 26.08 0.0142 25.61 0.0140 25.14 0.0137 24.68 0.0134 24.21 0.0132 23.74 0.0129 23.28 0.0127 22.81 0.0124 22.34 0.0122 21.87 0.0119 21.41 0.0116 20.94 0.0114 20.47 - 4 - Sytl-r Till? cF / 9 7/3/96 8:39:55 1319.1 0.0317 1284.1 0.0315 1249.7 0.0314 1215.7 0.0313 1182.1 0.0312 1149.0 0.0310 1116.,4 0.0309 1084.3 0.0308 1052.6 0.0306 1021.4 0.0305 990.7 0.0304 960.4 0.0303 930.6 0.0301 901.3 0.0300 872.4 0.0299 844.0 0.0297 816.0 0.0296 788.5 0.0295 761.5 0.0293 735.0 0.0292 708.9 0.0291 683.3 0.0290 658.2 0.0288 633.5 0.0287 609.3 0.0286 585.5 0.0284 562.3 0.0283 539.4 0.0282 517.1 0.0281 495.2 0.0279 473.8 0.0278 452.9 0.0277 432.4 0.0275 s�rA; i0 of / 9 • • 9 C:\PBWORKS\DOC\826.PSS 7/3/96 8:40:50 30 3810 63.5 0.124 432 0.0111 20.00 412.4 0.0274 30 3840 64 0.119 412 0.0109 19.53 392.9 0.0273 30 3870 64.5 0.113 393 0.0106 19.07 373.8 0.0272 30 3900 65 0.108 374 0.0103 18.60 355.2 0.0270 30 3930 65.5 0.102 355 0.0101 18.13 337.1 0.0269 30 3960 66 0.097 337, 0.0098 17.66 319.4 0.0268 30 3990 66.5 0.092 319 0.0096 17.19 302.2 0.0266 30 4020 67 0.087 302 0.0093 16.72 285.5 0.0265 30 4050 67.5 0.082 286 0.0090 16.25 269.3 0.0264 30 4080 68 0.078 269 0.0088 15.78 253.5 0.0262 30 4110 68.5 0.073 253 0.0085 15.31 238.2 0.0261 30 4140 69 0.069 238 0.0082 14.84 223.3 0.0260 30 4170 69.5 0.064 223 0.0080 14.37 208.9 0.0259 30 4200 70 0.060 209 0.0077 13.90 195.0 0.0257 30 4230 70.5 0.056 195 0.0075 13.43 181.6 0.0256 30 4260 71 0.052 182 0.0072 12.96 168.6 0.0255 30 4290 71.5 0.049 169 0.0069 12.49 156.2 0.0253 30 4320 72 0.045 156 0.0067 12.02 144.1 0.0252 30 4350 72.5 0.041 144 0.0064 11.55 132.6 0.0251 30 4380 73 0.038 133 0.0062 11.08 121.5 0.0249 30 4410 73.5 0.035 122 0.0059 10.60 110.9 0.0248 30 4440 74 0.032 111 0.0056 10.13 100.8 0.0247 30 4470 74.5 0.029 101 0.0054 9.66 91.1 0.0246 30 4500 75 0.026 91 0.0051 9.18 81.9 0.0244 30 4530 75.5 0.024 82 0.0048 8.71 73.2 0.0243 30 4560 76 0.021 73 0.0046 8.23 65.0 0.0242 30 4590 76.5 0.019 65 0.0043 7.75 57.2 0.0240 30 4620 77 0.016 57 0.0040 7.28 50.0 0.0239 30 4650 77..5 0.014 50 0.0038 6.80 43.2 0.0238 30 4680 78 0.012 43 0.0035 6.32 36.8 0.0237 30 4710 78.5 0.011 37 0.0032 5.84 31.0 0.0235 30 4740 79 0.009 31 0.0030 5.36 25.7 0.0234 30 4770 79.5 0.007 26 0.0027 4.87 20.8 0.0233 7 5 SyFFr Xt; �/ of / 9/ • C:\PBWORKS\DOC\826.PSS 7/3/96 8:41:41 30 4800 80 0.006 21 0.0024 4.38 16.4 0.0231 30 4830 80.5 0.005 16 .0.0022 3.89 12.5 0.0230 30 4860 81 0.004 13 0.0019 3.40 9.1 0.0229 30 4890 81.5 0.003 9 0.0016 2.90 6.2 0.0227 30 4920 82 0.002 6 0.0013 2.39 3.8 0.0226 30 4950 82.5 0.001 4 0.0010 1.88 1.9 0.0225 30 4980 83 0.001 2 0.0007 1.34 0.6 0.0223 30 5010 83.5 0.000 1 0.0004 0.74 -0.1 0.0222 30 5040 84 -0.000 -0 #NUM! #VALUE!#VALUE!#VALUE! 30 5070 84.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5100 85 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5130 85.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5160 86 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5190 86.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5220 87 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5250 87.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! . 30 5280 88 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5310 88.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5340 89 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5370 89.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5400 90 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5430 90.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5460 91 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5490 91.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5520 92 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5550 92.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5580 93 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5610 93.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5640 94 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5670 94.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5700 95 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5730 95.5 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! 30 5760 96 #VALUE!#VALUE!#VALUE!#VALUE!#VALUE!#VALUE! W. c /,g 85% TSS REMOVAL 30 FOOT VEGETATED FILTER REQUIRED �#PTH: 3' 3.5' 4.0'. 4.5' S.'0'. 5.5' 6.0' 6.5' 7.0" 7.5'• LAP % 10% .9 .8 .:.7 .6', .5 0 0 0 0 0 '20 % L7.- 1.3 1.2 1.1 1.0 q.. .8 .7 6 .5 30% 2.5 2.2 1.9 .1.8'. 1.6 1.5- 1.3 1.2 1.0 S. 40% 3.4. 3:0.. 2..6 .2.4, 2.1-.. 1.9 1.6 1.4.. L 1 1.0 50% .4.2 3.7 3.3., 3.0 2.7 12.4 2.1 1.8 .1.5 1.3 6 0% 5.0 4.5 3.8 3.5 .3.2 2.9 '2.6 23 2.0. 1.6 70% 6.0 , 5.2 4.5 4.1 3.7 3.1 2.9 2.5 2.1 1.8 80% 6.8 6.0 5.2 4.7 4.2. 3.7 3.2 2.7 2.2 2.0 90 7.5 6.5 5.8 5.3,. - 4.8 4.3 3.8 3.3 2.8 1.3 100% 1 8.2 7.4 6.8 - 6.2 : 5.6 , 5�O 4.4 3.8 3.2 it[ 2.6 i 90% TSS REMOVAL NO VEGETATED FILTER REQUIRED DEPTH 3' 3.5' 5;0, 5.5' 6.0' 6.5, 7.0' 7.5' IMP % 10% 1.3 1.0 .8 1-.7 .6 .5 4 .3 .2 1 20% 2.4 2.0 1.8 1.7 1.5 1.4 1.2 1.0 .9 .6 30% 3.5 3.0 2.7 2.5 2.2 1.9 1.6 1.3 1.1 .8 40% 4.5 4.0 3.5 3.1 1.8 2.5 2.1 1.8 1.4 1.1 50% 5.6 5.0 4.3 3.9 3.5 3.1 2.7 2.3 1.9 1.5 60% 7.0 6.0 5.3 4.8 4.3 3.9 3.4 2.9 2.4 1.9 .70% 8.1 7.0 6.0 5.5 5.0 4.5 19 3.4 2.9 2.3 80% 9.4 8.0 7.0 6.4 :5.7 5.2 4.6 4.0 3.4 2.8 90% 10.7 9.0 7,9, 7.2 6.5 5.9 5.2 4.6 3.9 3.3 % 12.0 10:0 8.8 8.1 7.3 6.6 5.8 5.1 4.3 3.6 DEPTH -DURATION -FREQUENCY TABLE by N.R. Malcom P.E. - C.E.Dept, NCSU - LOCATION: -------- >Charlotte, NC Raleigh, NC - Return Period -->- DURATION 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr [in] [in] [in] [in] [in] [in] 5 min 0.47 0.54 0.60 0.69 0.75 0.82 10 min 0.76 0.89 - .0.99 1.14 1.25 1.36 15 min 0.97 1.14 1.26 1.45 1.59 1.74 30 min 1.31 1.61 1.82 2.13 2.37 2.61 60 min 1.67 2.10 - 2.41 2.84 3.18 3.52 2 hr 1.87 2.35 2.68 . 3.16 3.53- 3.90 -3 hr 2.07 2.59 - 2.95 3.47 3.88 4.29 6 hr 2.59 3.20 3.64 4.28 4.77 5.26 12 hr 3.04 3.75 - 4.26 4.99 5.566.13 24 hr 3.50- 4.31 4.88 5.71 6.36 7.00 INTENSITY -DURATION -FREQUENCY TABLE LOCATION: -------- >Charlotte; NC Return Period -->" - DURATION 2 yr.-5 yr .r 10-yr 25-yr .. 50 yr 100-yr.. - [in/hrl .' [in/hrl. '[in/hrl [in/hrl [in/hr7 [in/hrl 5 min.. 5 64.". 6.54 '., 7.22 8.24 9.04 9.84 10 min 4.59 .. 5.37-5.95 6.82 7.50 8.18 15 min 3.88 4.55 5.05- _ 5.79 6.38 6.96 - 30 min 2.63 3.22. -2.10 '3.65 4.26 4.75 5.22 60 min 1.67 .. 2.41 2.84 3.18 3.52 2 hr 0.94 1.17 1.34 1.58 1.77 1.95 3 hr 0.69 0.86 0.98 1.16 1.29 1.43 6 hr 0.43 0.53 0.61 - 0.71 0.79 _ 0.88 12 hr 0.25 0.31 0.36 0.42 0.46 0.51 24 hr 0.15 0.18 0.20 0.24 -0.26 0.29 INPUT DATA: LOCATION: -------- >CharLotte. NC Duration 2-yr P 100-yr P Source [in] [in] 5 min 0.47 0.82 NOAA HYDRO-35 15 min 0.97 1.74 NOAA HYDRO-35 60 min 1.67 3.52 NOAA HYDRO-35 24-hr 3.50 7.00 USW3 TP-40 <---- DATA ---->I IDF Equations: I = 9/(h+T) for 5<T<120 min 2 130 18 5 166 21 10 191 22 25 228 23 50 256 24 100 284 24 DEPTH -DURATION -FREQUENCY TABLE by H.R. Malcom,-P.E. C.E.Dept, NCSU LOCATION: -------- >Wilmington, NC Raleigh, NC Return Period --> DURATION 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr [in] [in] [in] [in) [in] [in] 5 min 0.49 0.55 0.60 0.68 0.74 0.80 10 min 0.84 0.96 1.05 1.19 1.30 1.41 15 min 1.09 1.24 1.36 1.54 1.69 1.83 30 min 1.58 1.90 2.12 2.46 2.72 2.98 60 min 2.10 2.58 2.92 3.41 3.80 - 4.18 2 hr 2.36 2.93� _ 3.34 3.92 4.37 4.82 3 hr 2.63 3.29 3.76 4.42 4.94. 5.46 6 hr 3.30 4.20 4.82 5.71 6.40 7.09 12 hr 3.90 5.00 5.77 6.86 7.70 8.55 24 hr 4.50 5.81 6.72 8.01 9.01 10.00 INTENSITY -DURATION -FREQUENCY TABLE LOCATION: -------- >Wilmington, NC Return Period --> -DURATION 2-yr. 5-yr 10-yr 25-yr -50-yr. 100-yr [in/hrl On/hr] [in/hr7 [in/hrl [in/hrl - [in/hr) 5 min 5.88 6.63 7.2 8.15 - 8.87 9.60 10 min 5.06 5.76 7.13 7.79 8.45 15 min 4.36 4.97 5.45 6.17 6.75 7.32 30 min 3.17 - 3.79 4.25 4.92 5.44 5.96' 60 min 2.10 2.58 � 2.92 3.41 3.80 4.18 2 hr ._ 1.18 1.47 1.67 1.96 2.19 2.41 3 hr 0.88 1.10 1.25 � 1.47 1.65 1.82 6 hr 0.55 0.70 0.80 0.95 1.07 1.18 - 12 hr 0.33 0.42 0.48 0.57 0.64 0.71 24 hr 0.19 0.24 0.28, 0.33 0.38 0.42 INPUT DATA: IDF Equations: I = 9/(h+T) for 5<T<120 min LOCATION: -------- >Wilmington, NC ___ ______ R 9 Duration 2-yr P 100-yr P Source [in] Iird 5 min 0.49 0.80 NOAA HYDRO-35 15 min 1.09 " 1.83 NOAA HYDRO-35 60 min 2.10 4.18 NOAA HYDRO.35 24-hr 4.50 10.00 USWS TP-40 1<---- DATA ---->I 2 171 24 5 219 28 10 252 30 25 300 32 50 338 33 100 376 34 INTENSITY —DURATION —FREQUENCY FUNCTIONS ..Cwlotta, NC 10 9 e 7 � g v « s m4 2, 1 0 0 20 40 ' a0 a(l 100 120 Time of D�atlon Cmin) CI 2 + 5 a 10 a 25 x so 0 100 INTENSITY —DURATION -FREQUENCY FUNCTIONS W1 lmlrgton, 10 9 a AN c f•.0 m _ 1�A 3 2 1 0 20 ' 40' -" ..'so - 80 100 120 1 ; Tim of awatlon (min) 13 2 + 5 0 10 a '[ 25 x 5o 0 100 Sf/�ET �; iS pf i ar, Exhibit l -,Table of Raiional;runoff coefficients Description C Source _.. y Roof, inclinedMalcom Street, driveway, sidewalk 0: Chow, 1964 Parking lot 0.90: Malcom Roof, flat Commercial, generalized g 0.90, 0.85 .Malcom. Malcom Apartments; schools,'churches 0.60 WSSC, c.1968 '>• Residences, 10 dwellings/arec, 0.60' Malcom:... Residences, 6 dwellings/acre,' • 055 ; Mal com Residences; 4 dwellings/acre 0.50 Malcom Residences; 2 dwellings/acre .;• ;, 0:40; Malcom; Unimproved cleared area `Malcom Lawn, dense soil, steep;>7% F 0.35 Chow, 1964" Playground . 0.35. Chow, 1964 Park, cemetery. 0.25.. Chow, 1964 Lawn, dense soil, avg 2-7% • p 2, i Chow, 1964., -�j Wooded, sparse ground litter mil` � Malcom Lawn, dense soil, flat 2% Chow, 1964 Lawn, sandy, avg 2-7% " 0.15 Chow, 1964 Lawn, sandy, flat <2% 0.10 Chow, 1964, . Wooded, deep ground litter 0.10, Malcom . i; j Exhibit? ' • Minimum slopes. for pipe selection. Minimum slope required,to maintain stated minimum velocity at full flow. Material . Concrete Concrete , , Cotr ILld Corr Mtl Application ., Storm :; Sanitary ' S Manning.n. 0.013 0 O1 O10rm 24< 0 024 ,I Min V (ft/sec) 3 T? S ` 3.. , � 2 Pipe Diameter (in) Minimum Slope ` 15 0.00325 0.00144 0.01107 0.00492, 18 0.00255 0.00113 0.00868 0.00386 21 * : ' •,.0.00207 '0.00092 fO.00707 0.00314 24 0.00174 0.00077 0.00592 .. 0:00263 27 * .0.00148 '0.00066 0.00506 0.00225 30 0.00129 `0:00057 ' - --10.00439 .:. • . 0.00195 33 * 0.00114 10.00050 0.00387 0.00172 36 - 0.00101 0.00045 ` - - •0.00345 _ 0.00281�( ... 0.00153 0.00125 42 0.00092 P0.00037 ' ;48 0.000690.00235 '.. :0.00104..,.?.. 54 0.00059 :0.00026 0.00201 1 0.00089 O 60 0.00051 ... !0:00023.. 0.00020 0.00174 0.00154 '.. 0.00077 0.00068 66 0.00045 ; . 72 0.00040 0.00018: 0.00137 .0.00061 j * Non-standard in some markets :1r „ . Exhibit 8 .. W. Abbreviated Table of Values;of Manning Roughness Coefficients s I Description, of Lining n Reinforced concrete pipe 0.013 Corrugated metal pipe',; 0.024 Concrete, trowelled finish 0.013 Concrete, float finish:.., 0.015 Street gutter'or'paved channel' 0.015 ....Earth, straight and uniform 0.022 Grass -lined swales ,. 0.030 Unmaintained brushy channel `0.080 Stone=lined channel (4-inch) 0.028. Stone -lined channel (6 in) 0.030 Stone -lined channel, (9-in),,, Stone lined channel;,(12-in • 0.034 Stone -lined channei,(15-in) .... 0.035 Stone -lined channel (187m) 0.036 . VI-8 SHSFT ; /,z CF i j Exhibit 10 Suggested Maximum Velocities for Various Channel Linings i Description •. P Allowable , Velocity(ft/sec) _ Native linings Fine sand Sandy loam . 2.5 .: Silt loam 3.0• .. Ordin firm loam azY ' 3.5 .'...Fine gravel : . 5.0 .. Stiff clay ,. 5.0 ".: ' I Grasse, . :. .. , . -',Uncertain maintenance !' Good cover proper:maintenance . 5.0; Quarry Stone i Equivalent Allowable Velocity (ft/sec) Spherical for:siated;-sideslope . Diameter (inches) 5/1 2/1, 3/1 4/1 12/1 r .:.. 6 7 1 6.0 7.7 8.0 8.4 9.0 9 7.2 8.9 9.4 9.8 - 10.2 10.8 12 8.5 10.2`. 10.7 . 11.2 11.8 12.5 15 9.5 1 L5 : 12.0 12.7 13.3 ' 14.0 18 10.7 12.6 13.2 14.0 14.4 15.3 4 24 12.5 14.3..,:- 15.1, . 16.2: J6.7 17.6 30 14.0 17.0 18.2 18.7 19.7 36 15.4 17.4 ' . 18.7 20.0 20.5 . 21.5 i Vi-101 h W �L '.. ' ...-:vim... .. -. '.", .. .. ...r..• CHART .. . SD2.:- ... 150 _ 100 60 100 10,000 _ 60 N 50 .. W J 50 40 f 5,000. Z 40 J 30 .O 7 ; w 25 > 30 Q 3,000 p .<, _ F 20 Q 20 USE.fNOMOGRAPH T FOR NATURAL,+ LL 2,000 Z 15 Z BASINS._WITH ALL, DEFINED CHANNELS O FOR.:OVERLAND`FLOW ON'BARE-EARTH,a = 1,500 a. AND FOR MOWED GRASS ROADSIDE 0 10 w 10 CHANNELS ` i - W 1,000 0 FOR OVERLAND FLOW, GRASSED SURFACES, g - MULTIPLYT, BY-2 ZO -` �. . tj :D 6 , FOR OVERLAND FLOWTCONCRETE OR 500 g v) ASPHALT ,SURFACES, MULTIPLY Q O ,Tc . tAJ p 3 FOR CONCRETE CHANNELS, MULTIPLY Tc 300 ._ 3 BY 0.2 - — 200 x 2 w 150 2 2 _ r L3 0.385 100" Tc _ \ H /. i F E u CHART SD-b O p o e n h a M IN n O m n 7 to I N h O HEADWATER DEPTH IN DIAMETERS (HW/D) i r- tn S� m r r w s Y n _ N Q � y SIO (V N N O O W N N no g O O 0 O 0 O o0 g000 o a e o h a ri a i j• � W o Q'>- Y yy • - • • C p 2 � 8 i � � r • W 0 0 O > V Z. s�8 m 1(l �_ m O= O v O O N = c = p0 0 0 o to M, 0 m . N 0 m .sD n a ro N — DISCHARGE'(0) IN CFS p wN O ♦ m \^1N r M O P dom Ifl f 1/1 N O p w 1- W 1fl Y �f M M 1� N N N m 1f1 N REVISIONS DIAMETER OF CULVERT • (D) IN INCHES T[ D[IgUPTION HEADWATER DEPTH FOR CONCRETE PIPE CULVERTS WITH INLET CONTROL APPRWID:DST& e ITY OF GREENVILLE, N.ENGINEERING DEPT. 2a FINANCIAL RESPONSIBILITY/OWNERSHIP FORM SEDIMENTATION POLLUTION CONTROL ACT No person may Initiate any land -disturbing activity on one or more contiguous acres as covered by the Act before this form and an acceptable erosion and sedimentation control plan have been completed and approved by the Land Ouality Section, N.C. Department of Environment, Health, and Natural Resources. (Please type or print and, If question Is not applicable, place N/A in the blank.) Part A. 1. Project Name 1612 Front Street 2. Location of land•disturbing activity: County '. Carteret " Clty or Township Beaufort and Highway / Street SR 1312 .• .•..1" ' .. 3. Approximate date land disturbing activity will be commenced: August 1, 1996 4. Purpose of development' (residential; commercial;'indu�tdal;'etc.)':' Residential 5. Total acreage disturbed or uncovered (including off -site borrow and waste areas) : 2.74 ac 6. Amount of fee enclosed $ 70.00 7. Has an erosion and sedimentation control plan been filed ? Yes X No 8. Person to contact should sedimentcontrol issues arise during land -disturbing activity. • Name Joe H..Christian_ _. Telephone (919) 728-5462 9..Landowner (s) of Record ( Use blank page to list additional owners.): Mr. & Mrs. P. E. Davidson, 'Jr. `", ',T; `: Name (s) "4407`Ortega•Forest Drive li Current Main Address '' ' 1, 9 Current Street Address. Jacksonville, Florida 32210 City State Zip City State Zip 10. Recorded in Deed Book No. • 630 and- 492 - Page No. 411 and 352 Part B. .. 1. Person (s) or firms (s) who are financially responsible for this land -disturbing activity (Use the blank page to list additional persons or firms):.-. Joe H..Christian Front Street Associates, L.L.C. Name .of_Person -(s)or Firm (s) - P.O.Box 659 P.O. Box 659 Matting Address street...,.0.,W 1, • Beaufort. N.C.• 28516 BeauforiL, N.0 t3I4 Clt State Zi N State Zip Y _.. _ P'. Ci rp Telephone (919) 872-4747 P Telephori �(� )087Z47 2. (a) It the Financially Responsible, Party is not a resident of North Carolina give name and street address of a North Carolina Agent. X Name Mailing Address City State Zip ;City ,.. ' State Zip - Telephone Telephone (b) If the Financially Responsible Party is a Partnership. or other person engaging in business under an assumed name, attach a copy of the certificate,of assumed name. If the Financially Responsible Party Is a Corporation give name and street address of the Registered Agent. F Name of Registered Agent Mailing Address ,,, ;Street Address (M , City State Zip ":-City.. .. State Zip Telephone Telephone 'The above information is true and correct to the best of my knowledge and belief. and was provided by me under oath. ( This form must be signed by the financially responsible person If an individual or his attomey-in- fact or if not an individual by an officer, director, partner, or registered agent with authority.to execute Instru- ments for the finanacially responsible person ). I agree to provide corrected information should there be any change in the Information provided herein. Joe H. Christian Authorized Agent Type or print nape Title or Authority Signature / Date 26, 1996 bion John Viventi a Notary Public of the County of Carteret State of North Carolina, hereby certify that Joe H. Christian appeared personally before me this day and being duly sworn acknowledged that the above forth was exe- cuted by him. Rn I Ifio i tarial seal, this 26th day of June ig 96 r p pOTARY ;' de� v7, se 1t ": otary 7 pUsue � :" -My commission expiresMay"5 .. r11