HomeMy WebLinkAboutSW8050316_HISTORICAL FILE_20061116STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO
SW8 05W&(o
DOC TYPE
❑ CURRENT PERMIT
❑ APPROVED PLANS
';�tk HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
Roob I l
YYYYM M DD
�OF NATFgO Michaol F Easley Governor
William Ross Jr Secretary
rNorth Carolina Department of Environment and Natural Resources
> 1
O� Alan W Klimek P E Director
Division of Water Quality
November 16, 2006
Mr Arthur Kepes, Manager
Leland Retail Investments, LLC
2361 South Centennial Drive
Aiken, SC 29803
Subject Approved Plan Revision
Wal-Mart at Westgate Leland — Outlot 2
Stormwater Project No SW8 050316 Modification
Brunswick County
Dear Mr Kepes
On November 9, 2006, the Wilmington Regional Office received a plan revision for Stormwater Management
Permit Number SW8 050316 Modification The revisions include the proposed construction of 26,155 square feet
of built -upon area on Outlot 2 The built -upon area allotted to Outlot 2 by Stormwater Management Permit No
SW8 050316 is 44,954 square feet This project proposes 26,155 square feet It has been determined that a
formal permit modification is not required for the proposed changes We are forwarding you an approved copy of
the revised plans for your files Please add the attached plans to the previously approved plan sheets
Please be aware that all terms and conditions of the permit issued on November 7, 2006, remain in full force
and effect Please also understand that the approval of this revision to the approved plans for the subject State
Stormwater Permit is done on a case -by -case basis Any other changes to this project must be approved
through this Office prior to construction The issuance of this plan revision does not preclude the permittee
from complying with all other applicable statutes, rules, regulations or ordinances which may have
jurisdiction over the proposed activity, and obtaining a permit or approval prior to construction
Please be aware that pnor to the sale or transfer of ownership of any portion of the property deed restrictions and
covenants must be recorded (see Section II — Item 16 of State Stormwater Management Permit SW8 050316 dated
November 7, 2006) In addition, each outparcel or future development area whose ownership is not retained by
the permittee must obtain a separate Offsite State Stormwater Management Permit prior to any construction on
the lot
If you have any questions concerning this matter, please do not hesitate to call me at (910) 796-7345
Sincerely,
p p C
Rhonda Hall
Environmental Engineer
ENB\rbh S \WQS\STORMWATER\PERMIT\050316PR_outlot2 nov06
cc Brian Arnold, Arby's Restaurant Group
Marc S Newman, Omni Consulting Services
Brunswick County Building Inspections
Rhonda Hall
Wilmington Regional Office
Central Files
North Carolina Din ision of Water Quality 127 Cardinal Drive Extension Wilmington NC 28405 Phone (910) 796 7215
Wilmington Regional Office Internet www newateryualitv or Fax (910) 350 2004
An Equal OpportunitylAffirmatme Action Employer— 50% Recycled110% Post Consumer Paper
NorthCarohna
,Naturally
Customer Service
1 877 623 6748
OFFICE USE ONLY
Date Received Fee Paid Permit Number
State of North Carolina o s � e
Department of Environment and Natural Resources //
Division of Water Quality SW 5 �� b
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This form may be photocopied for use as an original
I GENERAL INFORMATION
I Applicants name (specify the name of the corporation individual etc who owns the project)
Leland Retail Investments, L L C
2 Print Owner/Signing Officials name and title (person legally responsible for facility and compliance)
Arthur Kepes, VP of WR5 Realty Inc Manager of the Applicant
3 Mailing Address for person listed in item 2 above
2361 South Centennial Drive
City Aiken
Telephone Number
803 i 649 1411
State SC
Zip 29803
4 Project Name (subdivision facility or establishment name - should be consistent with project name on plans
specifications letters operation and maintenance agreements etc)
Proposed Retail Shopping Center Leland NC
5 Location of Project (street address)
One mile south of intersection of Hwy 74 and Hwy 17
City Town of Leland County Brunswick County
6 Directions to project (from nearest major intersection)
One mile south of intersection of Hwv 74 and Hwy 17, at West Gate Drive and New Point
7 Latitude 34 208 N
Longitude 780257 W
of project
8 Contact person who can answer questions about the project
Name David Graffius, Gray Engineering Telephone Number (864 )297 3027
II PERMIT INFORMATION
1 Specify whether project Is (check one) New Renewal X Modification
Form S WU 101 Version 3 99 Page l of 4
c) "\'�w' -'�
.)
2 If this application is being submitted as the result of a renewal or modification to an existing permit list the
existing permit number SW8 050316 and Its issue date (if known) 04 22 05
3 Specify the type of project (check one)
_Low Density x High Density Redevelop _General Permit _Other
4 Additional Project Requirements (check applicable blanks)
_CAMA Major X Sedimentation/Erosion Control _404/401 Permit _NPDES Stormwater
Information on required state permits can be obtained by contacting the Customer Service Center at
l 877 623 6748
III PROJECT INFORMATION
1 In the space provided below summarize how stormwater will be treated Also attach a detailed narrative
(one to two pages) describing stormwater management for the project
Two permanent on -site wet detention ponds will provide permanent water quality and detain the 2, 10 and
25-year storm events The ponds were sized to detain Outlot N2 as well as all the other Outlot storm water
2 Stormwater runoff from this project drains to the Cape Fear River basin
3 Total Project Area 1 29 acres 4 Project Built Upon Area 4655 %
5 How many drainage areas does the project have? I
6 Complete the following information for each drainage area If there are more than two drainage areas In the
project attach an additional sheet with the Information for each area provided in the same format as below
Basin Information
Drainage Area I
Drainage Area 2
Receiving Stream Name
lackeys Creek
Receiving Stream Class
C, Sw
Drainage Area
1 29 Ac 56 192 SF
Existing Impervious Area
Proposed Impervious Area
Gac res 2673"F QLL, , IN
% Impervious" Area (total)
46 55%
Impervious Surface Area
Drainage Area I
Drainage Area 2
On -site Buildings
3 050 SF 07AC
On -site Streets
0 SF 0 AC
On site Parking
22 234 SF 0 51 AC
On -site Sidewalks
871 SF 0 02 AC
Other on site See Attached
0 SF 0 AC
Off -site
0 SF 0 AC
Total 26 155 5F 0 60 Acres
Total
Impervious area is defined as the built upon area Including but not limited to buildings roads parking areas
sidewalks gravel areas etc
"Off -site drainage to detention pond (Stormwater Permit #990807) from Lots No 8 and No 9
Form S WU-101 Version 3 99 Page 2 of 4
How was the off site impervious area listed above derived?_
The off -site area was determined from existing conditions and USGS topographic and aerial photographic
information
IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants are required to be recorded for all
subdivisions outparcels and future development prior to the sale of any lot If lot sizes vary significantly a table
listing each lot number size and the allowable built upon area for each lot must be provided as an attachment
1 The following covenants are intended to ensure ongoing compliance with state stormwater management permit number
S W9 050116 as Issued by the Division of Water Quality These covenants may not be
changed or deleted without the consent of the State
2 No more than 44,954 square feet of any lot shall be covered by structures or impervious materials
Impervious materials include asphalt gravel concrete brick stone slate or similar material but do not Include wood
decking or the water surface of swimming pools
3 Swales shall not be filled In piped or altered except as necessary to provide driveway crossings
4 Built upon area in excess of the permitted amount requires a state stormwater management permit modification prior to
construction
5 All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control
system These connections to the stormwater control system shall be performed in a manner that maintains the Integrity
and performance of the system as permitted
By your signature below you certify that the recorded deed restrictions and protective covenants for this project
shall include all the applicable items required above that the covenants will be binding on all parties and persons
claiming under them that they will tun with the land that the required covenants cannot be changed or deleted
without concurrence from the State and that they will be recorded prior to the sale of any lot
V SUPPLEMENT FORMS
The applicable state stormwater management permit supplement form(s) listed below must be submitted for each
BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733 5083 for the status
and availability of these forms
Form SWU-102
Wet Detention Basin Supplement
Form SWU 103
Infiltration Basin Supplement
Form SWU 104
Low Density Supplement
Form SWU 105
Curb Outlet System Supplement
Form SWU 106
Off Site System Supplement
Form SWU 107
Underground Infiltration Trench Supplement
Form SWU 108
Neuse River Basin Supplement
Form SWU 109
Innovative Best Management Practice Supplement
Form SWU 101 Version 3 99 Page 3 of 4
VI SUBMITTAL REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ)
A complete package includes all of the Items listed below The complete application package should be
submitted to the appropriate DWQ Regional Office
Please indicate that you have provided the following required information by initialing in the space provided
next to each item
Initials
Original and one copy of the Stormwater Management Permit Application Form
One copy of the applicable Supplement Form(s) for each BMP
Permit application processing fee of $420 (payable to NCDENR)
Detailed narrative description of stormwater treatment/management
Two copies of plans and specifications including
Development/Project name
Engineer and firm
Legend
North arrow
Scale
Revision number & date
Mean high water line
Dimensioned property/project boundary
Location map with named streets or NCSR numbers
Original contours proposed contours spot elevations finished floor elevations
Details of roads drainage features collection systems and stormwater control measures
Wetlands delineated or a note on plans that none exist
Exlsting drainage (including off site) drainage easements pipe sizes runoff calculations
Drainage areas delineated
Vegetated bufrers (where required)
VIl AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf please complete this section
Designated agent (Individual or firm)
Mailing Address 665
Omni Consulting Services
74 South, Suite 125
City Peachtree City State GA Zip
Phone ( 704 ) 486-7370
Vlll APPLICANTS CERTIFICATION
30269
Fax ( 704 ) 486-8398
1 (print or type name of person listed in General Information item 2) Art Kepes
certify that the information included on this permit application form is to the best of my knowledge correct and
that the project will be constructed in conformance with the approved plans that the required deed restrictions
and protective cove ants will be recor ed and that the proposed project complies with the requirements of 15A
NCAC 2e 1000
Signature ��` crwL Date
Form SWU 101 Version 3 99 Page 4 of 4
i4
State of North Carolina
Department of Environment and Natural Resources S'� e
Division of Water Quality �wTS OS 03� �o
c' ate
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This form may be photocopied for use as an original
I GENERAL INFORMATION
1 Applicants name (specify the name of the corporation Individual etc who owns the project)
Leland Retail Investments, L L C
2 Print Owner/Signing Official s name and title (person legally responsible for facility and compliance)
Arthur Kepes, VP of WRS Realty, Inc, Manager of the Applicant
3 Mailing Address for person listed In item 2 above
2361 South Centennial Drive
City Aiken
Telephone Number (803
649-1411
State SC
Zip 29803
4 Project Name (subdivision facility or establishment name should be consistent with project name on plans
specifications letters operation and maintenance agreements etc)
Proposed Retail Shopping Center, Leland, NC
5 Location of Project (street address)
One mile south of intersection of Hwv 74 and Hwv 17
City Town of Leland County Brunswick County
6 Directions to project (from nearest major intersection)
One mile south of intersection of Hwy 74 and Hwy 17, at West Gate Drive and New Point Blvd
7 Latitude 34 208 N
78 0257 W
of project
8 Contact person who can answer questions about the project
Name David Graffius, Gray Engineering Telephone Number (864 )297-3027
II PERMIT INFORMATION
I Specify whether project is (check one) New Renewal X Modification
Form SWU-101 Version 3 99 Page I of 4
4
2 If this application is being submitted as the result of a renewal or modification to an existing permit list the
existing permit number SW8 050316 and its issue date (if known) 04-22 05
3 Specify the type of project (check one)
_Low Density x High Density _Redevelop _General Permit _Other
4 Additional Project Requirements (check applicable blanks)
_CAMA Major X Sedimentation/Erosion Control _404/401 Permit _NPDES Stormwater
Information on required state permits can be obtained by contacting the Customer Service Center at
1-877 623 6748
III PROJECT INFORMATION
1 In the space provided below summarize how stormwater will be treated Also attach a detailed narrative
(one to two pages) describing stormwater management for the project
Two permanent on -site wet detention ponds will provide permanent water quality and detain the 2,10 and
25-year storm events The ponds were sized to detain Outlot q2 as well as all the other Outlot storm water
2 Stormwater runoff from this project drains to the Cape Fear River basin
3 Total Project Area 129 acres 4 Project Built Upon Area 4655
5 How many drainage areas does the project have? 1
6 Complete the following Information for each drainage area If there are more than two drainage areas in the
project attach an additional sheet with the information for each area provided in the same format as below
Basin Information
Drainage Area 1
Drainage Area 2
Receiving Stream Name
Jackeys Creek
Receiving Stream Class
C, Sw
Drainage Area
1 29 Ac 56,192 5F
Existing Impervious' Area
Proposed Im ervious Area
Gres 2 F
VS5�
% Impervious* Area (total)
4655%
Impervious Surface Area
Drainage Area 1
Drainage Area 2
On -site Buildings
3,050 SF 07AC
On -site Streets
0 SF 0 AC
On -site Parking
22,234 SF 051 AC
On -site Sidewalks
871 SF 0 02 AC
Other on -site See Attached
0 SF 0 AC
Off -site
0 SF 0 AC
Total 26,155SF 060Acres
Total
Impervious area is defined as the built upon area Including, but not limited to, buildings, roads parking areas
sidewalks gravel areas etc
"Off -site drainage to detention pond (Stormwater Permit #990807) from Lots No 8 and No 9
Fonn SWU-101 Version 3 99
Page 2 of 4
7 How was the off site impervious area listed above derived?
The off -site area was determined from existing conditions and USGS topographic and aerial photographic
information
IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants are required to be recorded for all
subdivisions outparcels and future development prior to the sale of any lot If lot sizes vary significantly a table
listing each lot number size and the allowable built -upon area for each lot must be provided as an attachment
I The following covenants are intended to ensure ongoing compliance with state stormwater management permit number
SW8 050316 as issued by the Division of Water Quality These covenants may not be
changed or deleted without the consent of the State
2 No more than 44,954 square feet of any lot shall be covered by structures or Impervious materials
Impervious materials Include asphalt gravel concrete brick stone slate or similar material but do not Include wood
decking or the water surface of swimming pools
3 Swales shall not be filled In piped or altered except as necessary to provide driveway crossings
4 Built upon area in excess of the permitted amount requires a state stormwater management permit modification prior to
construction
5 All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control
system These connections to the stormwater control system shall be performed to a manner that maintains the Integrity
and performance of the system as permitted
By your signature below you certify that the recorded deed restrictions and protective covenants for this project
shall include all the applicable items required above that the covenants will be binding on all parties and persons
claiming under them that they will run with the land that the required covenants cannot be changed or deleted
without concurrence from the State and that they will be recorded prior to the sale of any lot
V SUPPLEMENT FORMS
The applicable state stormwater management permit supplement form(s) listed below must be submitted for each
BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733 5083 for the status
and availability of these forms
Form SWU 102
Wet Detention Basin Supplement
Form SWU-103
Infiltration Basin Supplement
Form SWU 104
Low Density Supplement
Form SWU 105
Curb Outlet System Supplement
Form SWU 106
Off -Site System Supplement
Form SWU 107
Underground Infiltration Trench Supplement
Form SWU 108
Neuse River Basin Supplement
Form SWU 109
Innovative Best Management Practice Supplement
Form SWU 101 Version 3 99 Page 3 of 4
VI SUBMITTAL REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ)
A complete package includes all of the items listed below The complete application package should be
submitted to the appropriate DWQ Regional Office
i Please indicate that you have provided the following required information by initialing In the space provided
next to each item
Initials
Original and one copy of the Stormwater Management Permit Application Form
• One copy of the applicable Supplement Form(s) for each BMP
• Permit application processing fee of $420 (payable to NCDENR)
• Detailed narrative description of stormwater treatment/management _
Two copies of plans and specifications Including
Development/Project name
Engineer and firm
Legend
- North arrow
Scale
Revision number & date
Mean high water line
Dimensioned property/project boundary
Location map with named streets or NCSR numbers
Original contours proposed contours spot elevations finished floor elevations
Details of roads drainage features collection systems and stormwater control measures
Wetlands delineated or a note on plans that none exist
Existing drainage (including off -site) drainage easements pipe sizes runoff calculations
Drainage areas delineated
Vegetated buffers (where required)
VII AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf please complete this section
Designated agent (individual or firm) Omni Consulting Services
Mailing Address 665 Hwy 74 South, Suite 125
City Peachtree Cit
Phone ( 704 ) 486-7370
VIII APPLICANTS CERTIFICATION
State GA Zip
30269
Fax ( 704 ) 486-8398
I (print or type name of person listed in General Information item 2) Art Kepes
certify that the information included on this permit application form Is to the best of my knowledge correct and
that the project will be constructed in conformance with the approved plans that the required deed restrictions
and protective cove ants will be recor ed and that the proposed project complies with the requirements of 15A
NCAC 2H 1000
r /
Signature VP Date